Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...
Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.
Holm, Anne; Aabenhus, Rune
2016-06-08
Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.
Wu, Hon-Yen; Peng, Yu-Sen; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu; Wu, Kwan-Dun; Tu, Yu-Kang; Chien, Kuo-Liong
2014-07-01
A random urine sample measuring the albumin concentration (UAC) without simultaneously measuring the urinary creatinine is less expensive than measuring the ratio of albumin to creatinine (ACR), but comparisons of their diagnostic performance for microalbuminuria screening among patients with diabetes mellitus (DM) have not been undertaken in previous meta-analyses. To compare the diagnostic performance of the UAC vs the ACR in random urine samples for microalbuminuria screening among patients with DM. Electronic literature searches of PubMed, MEDLINE, and Scopus for English-language publications from the earliest available date of indexing through July 31, 2012. Clinical studies assessing the UAC or the ACR of random urine samples in detecting the presence of microalbuminuria among patients with DM using a urinary albumin excretion rate of 30 to 300 mg/d in 24-hour timed urine collections as the criterion standard. Bivariate random-effects models for analysis and pooling of the diagnostic performance measures across studies, as well as comparisons between different screening tests. The primary end point was the diagnostic performance measures of the UAC or the ACR in random urine samples, as well as comparisons between them. We identified 14 studies, with a total of 2078 patients; 9 studies reported on the UAC, and 12 studies reported on the ACR. Meta-analysis showed pooled sensitivities of 0.85 and 0.87 for the UAC and the ACR, respectively, and pooled specificities of 0.88 and 0.88, respectively. No differences in sensitivity (P = .70), specificity (P = .63), or diagnostic odds ratios (P = .59) between the UAC and the ACR were found. The time point of urine collection did not affect the diagnostic performance of either test. The UAC and the ACR yielded high sensitivity and specificity for the detection of microalbuminuria. Because the diagnostic performance of the UAC is comparable to that of the ACR, our findings indicate that the UAC of random urine samples may become the screening tool of choice for the population with DM, considering the rising incidence of DM and the constrained health care resources in many countries.
Katayev, Alexander; Zebelman, Arthur M; Sharp, Thomas M; Samantha Flynn; Bernstein, Richard K
2017-04-01
Isolated non-albumin proteinuria (NAP) is a condition when urine total protein concentrations are elevated without elevation of urine albumin. The prevalence of NAP in the US population tested for both, urine total protein and albumin was assessed in this study. The database of a US nationwide laboratory network was queried for test results when random urine albumin was ordered together with urine total protein and also when timed 24-hour urine albumin was ordered together with urine total protein. The total prevalence of NAP in the US population tested for both, urine total protein and albumin was calculated for patient groups having normal and low-normal urine albumin (random and timed) with elevated and severely increased urine total protein (random and timed). Also, the prevalence of NAP was calculated for patients with normal urine albumin to assess the probability of missing proteinuria if only urine albumin is measured. The prevalence of NAP in the random samples group was 10.1% (15.2% for females and 4.7% for males). Among patients with normal random albumin, there were 20.0% (27.3% of females and 10.7% of males) patients with NAP. The prevalence of NAP in the timed samples group was 24.6% (29.8% for females and 18.5% for males). Among patients with normal timed urine albumin, there were 36.2% (40.0% of females and 30.8% of males) patients with NAP. There was a strong positive association with female gender and NAP in most patients groups. Testing for only urine (micro)albumin can miss up to 40% of females and 30.8% of males with gross proteinuria. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Optimizing Urine Processing Protocols for Protein and Metabolite Detection.
Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K
In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.
A random urine test can identify patients at risk of mesalamine non-adherence: a prospective study.
Gifford, Anne E; Berg, Anders H; Lahiff, Conor; Cheifetz, Adam S; Horowitz, Gary; Moss, Alan C
2013-02-01
Mesalamine non-adherence is common among patients with ulcerative colitis (UC), and can be difficult to identify in practice. We sought to determine whether a random urine test for salicylates could be used as a marker of 5-aminosalicylic acid (5-ASA) ingestion and identify patients at risk of non-adherence. Our aim is to determine whether measurement of salicylates in a random urine sample correlates with 5-ASA levels, and predicts an individual's risk of mesalamine non-adherence. Prospective observational study. Urinary salicylates (by colorimetry) and 5-ASA (by liquid chromatography and tandem-mass spectrometry) were measured in a random urine sample at baseline in patients and controls. Mesalamine adherence was quantified by patient self-reports at enrollment and pharmacy refills of mesalamine over 6 months. A total of 93 patients with UC taking mesalamine maintenance therapy were prospectively enrolled from the clinic. Random urine salicylate levels (by colorimetry) were highly correlated with urine 5-ASA metabolite levels (by mass spectrometry; R2=0.9). A random urine salicylate level above 15 mg/dl distinguished patients who had recently taken mesalamine from controls (area under the curve value 0.9, sensitivity 95%, specificity 77%). A significant proportion of patients (27%) who self-identified as "high adherers" by an adherence questionnaire (Morisky Medication Adherence Scale-8) had random levels of urine salicylate below this threshold. These patients were at higher risk of objectively measured non-adherence to mesalamine over the subsequent 6 months (RR: 2.7, 95% CI: 1.1-7.0). A random urine salicylate level measured in the clinic can identify patients who have not recently taken mesalamine, and who are at higher risk of longitudinal non-adherence. This test could be used to screen patients who may warrant interventions to improve adherence and prevent disease relapse.
Talamo, Giampaolo; Mir Muhammad, A; Pandey, Manoj K; Zhu, Junjia; Creer, Michael H; Malysz, Jozef
2015-02-11
Measurement of daily proteinuria in patients with amyloidosis is recommended at the time of diagnosis for assessing renal involvement, and for monitoring disease activity. Renal involvement is usually defined by proteinuria >500 mg/day. We evaluated the accuracy of the random urine protein-to-creatinine ratio (Pr/Cr) in predicting 24 hour proteinuria in patient with amyloidosis. We compared results of random urine Pr/Cr ratio and concomitant 24-hour urine collections in 44 patients with amyloidosis. We found a strong correlation (Spearman's ρ=0.874) between the Pr/Cr ratio and the 24 hour urine protein excretion. For predicting renal involvement, the optimal cut-off point of the Pr/Cr ratio was 715 mg/g. The sensitivity and specificity for this point were 91.8% and 95.5%, respectively, and the area under the curve value was 97.4%. We conclude that the random urine Pr/Cr ratio could be useful in the screening of renal involvement in patients with amyloidosis. If validated in a prospective study, the random urine Pr/Cr ratio could replace the 24 hour urine collection for the assessment of daily proteinuria and presence of nephrotic syndrome in patients with amyloidosis.
Electrical conductivity and total dissolved solids in urine.
Fazil Marickar, Y M
2010-08-01
The objective of this paper is to study the relevance of electrical conductivity (EC) and total dissolved solids (TDS) in early morning and random samples of urine of urinary stone patients; 2,000 urine samples were studied. The two parameters were correlated with the extent of various urinary concrements. The early morning urine (EMU) and random samples of the patients who attended the urinary stone clinic were analysed routinely. The pH, specific gravity, EC, TDS, redox potential, albumin, sugar and microscopic study of the urinary sediments including red blood cells (RBC), pus cells (PC), crystals, namely calcium oxalate monohydrate (COM), calcium oxalate dihydrate (COD), uric acid (UA), and phosphates and epithelial cells were assessed. The extent of RBC, PC, COM, COD, UA and phosphates was correlated with EC and TDS. The values of EC ranged from 1.1 to 33.9 mS, the mean value being 21.5 mS. TDS ranged from 3,028 to 18,480 ppm, the mean value being 7,012 ppm. The TDS levels corresponded with EC of urine. Both values were significantly higher (P < 0.05) in the EMU samples than the random samples. There was a statistically significant correlation between the level of abnormality in the urinary deposits (r = +0.27, P < 0.05). In samples, where the TDS were more than 12,000 ppm, there were more crystals than those samples containing TDS less than 12,000 ppm. However, there were certain urine samples, where the TDS were over 12,000, which did not contain any urinary crystals. It is concluded that the value of TDS has relevance in the process of stone formation.
Terry, Ana L; Cogswell, Mary E; Wang, Chia-Yih; Chen, Te-Ching; Loria, Catherine M; Wright, Jacqueline D; Zhang, Xinli; Lacher, David A; Merritt, Robert K; Bowman, Barbara A
2016-01-01
Background: Twenty-four–hour urine sodium excretion is recommended for monitoring population sodium intake. Because of concerns about participation and completion, sodium excretion has not been collected previously in US nationally representative surveys. Objective: We assessed the feasibility of implementing 24-h urine collections as part of a nationally representative survey. Design: We selected a random half sample of nonpregnant US adults aged 20–69 y in 3 geographic locations of the 2013 NHANES. Participants received explicit instructions, started and ended the urine collection in a urine study mobile examination center, and answered questions about their collection. Among those with a complete 24-h urine collection, a random one-half were asked to collect a second 24-h urine sample. Sodium, potassium, chloride, and creatinine excretion were analyzed. Results: The final NHANES examination response rate for adults aged 20–69 y in these 3 study locations was 71%. Of those examined (n = 476), 282 (59%) were randomly selected to participate in the 24-h urine collection. Of these, 212 persons [75% of those selected for 24-h urine collection; 53% (equal to 71% × 75% of those selected for the NHANES)] collected a complete initial 24-h specimen and 92 persons (85% of 108 selected) collected a second complete 24-h urine sample. More men than women completed an initial collection (P = 0.04); otherwise, completion did not vary by sociodemographic characteristics, body mass index, education, or employment status for either collection. Mean 24-h urine volume and sodium excretion were 1964 ± 1228 mL and 3657 ± 2003 mg, respectively, for the first 24-h urine sample, and 2048 ± 1288 mL and 3773 ± 1891 mg, respectively, for the second collection. Conclusion: Given the 53% final component response rate and 75% completion rate, 24-h urine collections were deemed feasible and implemented in the NHANES 2014 on a subsample of adults aged 20–69 y to assess population sodium intake. This study was registered at clinicaltrials.gov as NCT02723682. PMID:27413136
Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M
2016-08-01
The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.
Talamo, Giampaolo; Mir Muhammad, A.; Pandey, Manoj K.; Zhu, Junjia; Creer, Michael H.; Malysz, Jozef
2015-01-01
Measurement of daily proteinuria in patients with amyloidosis is recommended at the time of diagnosis for assessing renal involvement, and for monitoring disease activity. Renal involvement is usually defined by proteinuria >500 mg/day. We evaluated the accuracy of the random urine protein-to-creatinine ratio (Pr/Cr) in predicting 24 hour proteinuria in patient with amyloidosis. We compared results of random urine Pr/Cr ratio and concomitant 24-hour urine collections in 44 patients with amyloidosis. We found a strong correlation (Spearman’s ρ=0.874) between the Pr/Cr ratio and the 24 hour urine protein excretion. For predicting renal involvement, the optimal cut-off point of the Pr/Cr ratio was 715 mg/g. The sensitivity and specificity for this point were 91.8% and 95.5%, respectively, and the area under the curve value was 97.4%. We conclude that the random urine Pr/Cr ratio could be useful in the screening of renal involvement in patients with amyloidosis. If validated in a prospective study, the random urine Pr/Cr ratio could replace the 24 hour urine collection for the assessment of daily proteinuria and presence of nephrotic syndrome in patients with amyloidosis. PMID:25918613
Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.
Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah
2016-10-07
Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.
Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio
Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah
2016-01-01
Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930
Sullivan, Lauren A; Campbell, Vicki L; Onuma, Serene C
2010-07-15
To determine whether use of a closed urine collection system would decrease the incidence of nosocomial bacteriuria in hospitalized dogs, compared with use of an open urine collection system (used, sterile IV bags). Randomized controlled trial. 51 hospitalized dogs requiring indwelling urinary catheterization for >or= 24 hours. Dogs were randomly assigned to an open or closed urine collection system group. A standardized protocol for catheter placement and maintenance was followed for all dogs. A baseline urine sample was collected via cystocentesis for aerobic bacterial culture, with additional urine samples obtained daily from the urine collection reservoir. 27 dogs were assigned to the open urine collection system group, and 24 were assigned to the closed urine collection system group. The incidence of nosocomial bacteriuria in dogs with open urine collection systems (3/27 [11.1%]) was not significantly different from incidence in dogs with closed urine collection systems (2/24 [8.3%]). Median duration of catheterization was 2 days for dogs in both groups; the range was 1 to 7 days for dogs in the open group and 1 to 5 days for dogs in the closed group. Results suggested that for dogs requiring short-term indwelling urinary catheterization, the type of urine collection system (open vs closed) was not associated with likelihood of developing nosocomial bacteriuria. Use of a strict protocol for urinary catheter placement and maintenance was likely key in the low incidence of nosocomial bacteriuria in the present study.
Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi
2016-02-01
Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62 mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.
Pathak, Neha; Dodds, Julie; Khan, Khalid
2014-01-01
Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064
Gina, Phindile; Randall, Philippa J; Muchinga, Tapuwa E; Pooran, Anil; Meldau, Richard; Peter, Jonny G; Dheda, Keertan
2017-05-12
Urine LAM testing has been approved by the WHO for use in hospitalised patients with advanced immunosuppression. However, sensitivity remains suboptimal. We therefore examined the incremental diagnostic sensitivity of early morning urine (EMU) versus random urine sampling using the Determine® lateral flow lipoarabinomannan assay (LF-LAM) in HIV-TB co-infected patients. Consenting HIV-infected inpatients, screened as part of a larger prospective randomized controlled trial, that were treated for TB, and could donate matched random and EMU samples were included. Thus paired sample were collected from the same patient, LF-LAM was graded using the pre-January 2014, with grade 1 and 2 manufacturer-designated cut-points (the latter designated grade 1 after January 2014). Single sputum Xpert-MTB/RIF and/or TB culture positivity served as the reference standard (definite TB). Those treated for TB but not meeting this standard were designated probable TB. 123 HIV-infected patients commenced anti-TB treatment and provided matched random and EMU samples. 33% (41/123) and 67% (82/123) had definite and probable TB, respectively. Amongst those with definite TB LF-LAM sensitivity (95%CI), using the grade 2 cut-point, increased from 12% (5-24; 5/43) to 39% (26-54; 16/41) with random versus EMU, respectively (p = 0.005). Similarly, amongst probable TB, LF-LAM sensitivity increased from 10% (5-17; 8/83) to 24% (16-34; 20/82) (p = 0.001). LF-LAM specificity was not determined. This proof of concept study indicates that EMU could improve the sensitivity of LF-LAM in hospitalised TB-HIV co-infected patients. These data have implications for clinical practice.
A randomized trial of employment-based reinforcement of cocaine abstinence in injection drug users.
Silverman, Kenneth; Wong, Conrad J; Needham, Mick; Diemer, Karly N; Knealing, Todd; Crone-Todd, Darlene; Fingerhood, Michael; Nuzzo, Paul; Kolodner, Kenneth
2007-01-01
High-magnitude and long-duration abstinence reinforcement can promote drug abstinence but can be difficult to finance. Employment may be a vehicle for arranging high-magnitude and long-duration abstinence reinforcement. This study determined if employment-based abstinence reinforcement could increase cocaine abstinence in adults who inject drugs and use cocaine during methadone treatment. Participants could work 4 hr every weekday in a workplace where they could earn about $10.00 per hour in vouchers; they were required to provide routine urine samples. Participants who attended the workplace and provided cocaine-positive urine samples during the initial 4 weeks were invited to work 26 weeks and were randomly assigned to an abstinence-and-work (n = 28) or work-only (n = 28) group. Abstinence-and-work participants had to provide urine samples showing cocaine abstinence to work and maintain maximum pay. Work-only participants could work independent of their urinalysis results. Abstinence-and-work participants provided more (p = .004; OR = 5.80, 95% CI = 2.03-16.56) cocaine-negative urine samples (29%) than did work-only participants (10%). Employment-based abstinence reinforcement can increase cocaine abstinence.
Comer, Sandra D.; Sullivan, Maria A.; Yu, Elmer; Rothenberg, Jami L.; Kleber, Herbert D.; Kampman, Kyle; Dackis, Charles; O'Brien, Charles P.; Chiang, C. Nora; Hawks, Richard L.
2013-01-01
Context Naltrexone is a medication available in oral form that can completely block the effects produced by opioid agonists, such as heroin. However, poor medication compliance with naltrexone has been a major obstacle to the effective treatment of opioid dependence. Objective To evaluate the safety and efficacy of a sustained-release depot formulation of naltrexone in treating opioid dependence. Design, Setting, and Participants Randomized, double-blind, placebo-controlled, 8-week multi-center trial of male and female heroin-dependent patients who participated in the study between September 2000 and November 2003. Participants were stratified by years of heroin use (≥5, <4.9) and gender, and then randomized to receive one of three doses: placebo, 192 mg, or 384 mg depot naltrexone. Doses were administered at the beginning of Week 1 and then again four weeks later at the beginning of Week 5. All participants received twice-weekly relapse prevention therapy, provided observed urine samples, and completed other assessments at each visit. Main Outcome Measures Primary outcome measures were retention in treatment and percentage of opioid-negative urine samples. Results A total of 60 patients were randomized at two centers. Retention in treatment was dose related with 39%, 60%, and 68% of the patients in the placebo, naltrexone 192 mg, and naltrexone 384 mg groups, respectively, remaining in treatment at the end of the two-month treatment period. Analysis of the time to dropout revealed a significant main effect of dose with mean time to dropout of 27, 36, and 48 days, respectively, for the placebo, naltrexone 192 mg, and naltrexone 384 mg groups. The percentage of urine samples negative for opioids varied significantly as a function of dose, as did the percentage of urine samples negative for methadone, cocaine, benzodiazepines, and amphetamine. The percentage of urine samples negative for cannabinoids was not significantly different across groups. When the data were recalculated without the assumption that missing urine samples were positive, however, a main effect of group was not found for any of the drugs tested with the exception of cocaine, where the percentage of cocaine-negative urines was lower in the placebo group. Adverse events were minimal and generally mild in severity. This sustained-release formulation of naltrexone was well tolerated and produced a robust and dose-related increase in treatment retention. Conclusion The present data provide exciting new evidence for the feasibility, efficacy, and tolerability of long-lasting antagonist treatments for opioid dependence. PMID:16461865
Midstream clean-catch urine collection in newborns: a randomized controlled study.
Altuntas, Nilgun; Tayfur, Asli Celebi; Kocak, Mesut; Razi, Hasan Cem; Akkurt, Serpil
2015-05-01
We aimed to evaluate a recently defined technique based on bladder stimulation and paravertebral lumbar massage maneuvers in collecting a midstream clean-catch urine sample in newborns. A total of 127 term newborns were randomly assigned either to the experimental group or the control group. Twenty-five minutes after feeding, the genital and perineal areas of the babies were cleaned. The babies were held under the armpits with legs dangling. Bladder stimulation and lumbar paravertebral massage maneuvers were only applied to the babies in the experimental group. Success was defined as collection of a urine sample within 5 min of starting the stimulation maneuvers in the experimental group and of holding under the armpits in the control group. The success rate of urine collection was significantly higher in the experimental group (78%) than in the control group (33%; p < 0.001). The median time (interquartile range) for sample collection was 60 s (64.5 s) in the experimental group and 300 s (95 s) in the control group (p < 0.0001). Contamination rates were similar in both groups (p = 0.770). We suggest that bladder stimulation and lumbar paravertebral massage is a safe, quick, and effective way of collecting midstream clean-catch urine in newborns.
Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette
2014-01-01
Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560
A Randomized Trial of Employment-Based Reinforcement of Cocaine Abstinence in Injection Drug Users
Silverman, Kenneth; Wong, Conrad J; Needham, Mick; Diemer, Karly N; Knealing, Todd; Crone-Todd, Darlene; Fingerhood, Michael; Nuzzo, Paul; Kolodner, Kenneth
2007-01-01
High-magnitude and long-duration abstinence reinforcement can promote drug abstinence but can be difficult to finance. Employment may be a vehicle for arranging high-magnitude and long-duration abstinence reinforcement. This study determined if employment-based abstinence reinforcement could increase cocaine abstinence in adults who inject drugs and use cocaine during methadone treatment. Participants could work 4 hr every weekday in a workplace where they could earn about $10.00 per hour in vouchers; they were required to provide routine urine samples. Participants who attended the workplace and provided cocaine-positive urine samples during the initial 4 weeks were invited to work 26 weeks and were randomly assigned to an abstinence-and-work (n = 28) or work-only (n = 28) group. Abstinence-and-work participants had to provide urine samples showing cocaine abstinence to work and maintain maximum pay. Work-only participants could work independent of their urinalysis results. Abstinence-and-work participants provided more (p = .004; OR = 5.80, 95% CI = 2.03–16.56) cocaine-negative urine samples (29%) than did work-only participants (10%). Employment-based abstinence reinforcement can increase cocaine abstinence. PMID:17970256
Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A
2003-01-15
To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.
Beck, Thilo; Haasen, Christian; Verthein, Uwe; Walcher, Stephan; Schuler, Christoph; Backmund, Markus; Ruckes, Christian; Reimer, Jens
2014-01-01
Aims To compare the efficacy of slow-release oral morphine (SROM) and methadone as maintenance medication for opioid dependence in patients previously treated with methadone. Design Prospective, multiple-dose, open label, randomized, non-inferiority, cross-over study over two 11-week periods. Methadone treatment was switched to SROM with flexible dosing and vice versa according to period and sequence of treatment. Setting Fourteen out-patient addiction treatment centres in Switzerland and Germany. Participants Adults with opioid dependence in methadone maintenance programmes (dose ≥50 mg/day) for ≥26 weeks. Measurements The efficacy end-point was the proportion of heroin-positive urine samples per patient and period of treatment. Each week, two urine samples were collected, randomly selected and analysed for 6-monoacetyl-morphine and 6-acetylcodeine. Non-inferiority was concluded if the two-sided 95% confidence interval (CI) in the difference of proportions of positive urine samples was below the predefined boundary of 10%. Findings One hundred and fifty-seven patients fulfilled criteria to form the per protocol population. The proportion of heroin-positive urine samples under SROM treatment (0.20) was non-inferior to the proportion under methadone treatment (0.15) (least-squares mean difference 0.05; 95% CI = 0.02, 0.08; P > 0.01). The 95% CI fell within the 10% non-inferiority margin, confirming the non-inferiority of SROM to methadone. A dose-dependent effect was shown for SROM (i.e. decreasing proportions of heroin-positive urine samples with increasing SROM doses). Retention in treatment showed no significant differences between treatments (period 1/period 2: SROM: 88.7%/82.1%, methadone: 91.1%/88.0%; period 1: P = 0.50, period 2: P = 0.19). Overall, safety outcomes were similar between the two groups. Conclusions Slow-release oral morphine appears to be at least as effective as methadone in treating people with opioid use disorder. PMID:24304412
Stratton-Phelps, Meri; House, John K
2004-10-01
To determine whether feeding a commercial anionic dietary supplement as a urinary acidifier to male goats may be useful for management of urolithiasis. 8 adult sexually intact male Toggenburg, Saanen, and Nubian goats. Goats were randomly assigned by age-, breed-, and weight-matched pairs to an oat or grass hay diet that was fed for 12 days. On days 13 to 14 (early sample collection time before supplementation), measurements were made of blood and urine sodium, potassium, calcium, magnesium, chloride, phosphorus, and sulfur concentrations; blood and urine pH; urine production; and water consumption. During the next 28 days, the anionic dietary supplement was added to the oat and grass hay diets to achieve a dietary cation-anion difference of 0 mEq/100g of dry matter. Blood and urine samples were analyzed during dietary supplementation on days 12 to 13 (middle sample collection time) and 27 to 28 (late sample collection time). Blood bicarbonate, pH, and urine pH of goats fed grass hay and goats fed oat hay were significantly decreased during the middle and late sample collection times, compared with the early sample collection time. Water consumption and urine production in all goats increased significantly during the late sample collection time, compared with the early sample collection time. The anionic dietary supplement used in our study increases urine volume, alters urine ion concentrations, and is an efficacious urinary acidifier in goats. Goats treated with prolonged anionic dietary supplementation should be monitored for secondary osteoporosis from chronic urinary calcium loss.
Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S
2016-04-01
It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.
Fluoride in drinking water and human urine in Southern Haryana, India.
Singh, Bhupinder; Gaur, Shalini; Garg, V K
2007-06-01
The objective of this study was to determine the fluoride content in drinking water and urine samples of adolescent males aged 11-16 years living in Southern Haryana, India. A total of 30 drinking water sources in the studied habitations were assessed for fluoride contamination. Fluoride was estimated in the urine of 400 male children randomly selected from these habitations. The fluoride concentration in drinking water and urine samples was determined using USEPA fluoride ion selective electrode method. The mean fluoride concentration in drinking water samples of Pataudi, Haily Mandi and Harsaru villages was 1.68+/-0.35, 3.22+/-1.18 and 1.78+/-0.12 mg/l, respectively. The mean urinary fluoride concentration was 2.26+/-0.024 mg/l at Pataudi, 2.48+/-0.77 mg/l at Haily Mandi and 2.43+/-0.84 mg/l at Harsaru village. The higher fluoride levels in the urine of children may be associated to higher fluoride levels in drinking water. The accuracy of measurements was assessed with known addition method in water and urine. Mean fluoride recovery was 98.0 and 99.1% in water and urine. The levels obtained were reproducible with in +/-3% error limit.
Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi
2017-12-01
Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.
DeFulio, Anthony; Donlin, Wendy D; Wong, Conrad J; Silverman, Kenneth
2009-09-01
Due to the chronic nature of cocaine dependence, long-term maintenance treatments may be required to sustain abstinence. Abstinence reinforcement is among the most effective means of initiating cocaine abstinence. Practical and effective means of maintaining abstinence reinforcement programs over time are needed. To determine whether employment-based abstinence reinforcement can be an effective long-term maintenance intervention for cocaine dependence. Participants (n = 128) were enrolled in a 6-month job skills training and abstinence initiation program. Participants who initiated abstinence, attended regularly and developed needed job skills during the first 6 months were hired as operators in a data entry business and assigned randomly to an employment-only (control, n = 24) or abstinence-contingent employment (n = 27) group. A non-profit data entry business. Participants Unemployed welfare recipients who used cocaine persistently while enrolled in methadone treatment in Baltimore. Abstinence-contingent employment participants received 1 year of employment-based contingency management, in which access to employment was contingent upon provision of drug-free urine samples under routine and then random drug testing. If a participant provided drug-positive urine or failed to provide a mandatory sample, then that participant received a temporary reduction in pay and could not work until urinalysis confirmed recent abstinence. Cocaine-negative urine samples at monthly assessments across 1 year of employment. During the 1 year of employment, abstinence-contingent employment participants provided significantly more cocaine-negative urine samples than employment-only participants [79.3% and 50.7%, respectively; P = 0.004, odds ratio (OR) = 3.73, 95% confidence interval (CI) = 1.60-8.69]. Conclusions Employment-based abstinence reinforcement that includes random drug testing is effective as a long-term maintenance intervention, and is among the most promising treatments for drug dependence. Work-places could serve as therapeutic agents in the treatment of drug dependence by arranging long-term employment-based contingency management programs.
The consequence of delayed fixation on subsequent preservation of urine cells.
Ahmed, Hussain G; Tom, Murtada Am
2011-01-01
Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.
Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?
Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok
2012-01-01
Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881
A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.
Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera
2015-10-01
The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.
Effect of freeze/thaw cycles on several biomarkers in urine from patients with kidney disease.
Zhang, Yinan; Luo, Yi; Lu, Huijuan; Wang, Niansong; Shen, Yixie; Chen, Ruihua; Fang, Pingyan; Yu, Hong; Wang, Congrong; Jia, Weiping
2015-04-01
Urine samples were collected from eleven randomly selected patients with kidney disease, including diabetic nephropathy, chronic nephritis, and nephritic syndrome. Urine samples were treated with one of four protocols for freezing and thawing: freeze directly and thaw directly; freeze directly and thaw by temperature gradient; freeze by temperature gradient and thaw directly; and freeze by temperature gradient and thaw by temperature gradient. After one to six freeze/thaw cycles at -20°C or -80°C, different biomarkers showed differential stabilities. The concentrations of total protein, calcium, and potassium did not change significantly after five freeze/thaw cycles at either -20°C or -80°C. Albumin could only sustain three freeze/thaw cycles at -20°C before it started to degrade. We recommend that urine be stored at -80°C as albumin and the organic ions could sustain five and six freeze/thaw cycles, respectively, using the simple "direct freeze and direct thaw" protocol. Furthermore, in most cases, gradient freeze/thaw cycles are not necessary for urine sample storage.
Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh
2016-01-01
Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.
Price, James W
Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.
Estimating population salt intake in India using spot urine samples.
Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce
2017-11-01
To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.
McDonell, Michael G.; Leickly, Emily; McPherson, Sterling; Skalisky, Jordan; Srebnik, Debra; Angelo, Frank; Vilardaga, Roger; Nepom, Jenny R.; Roll, John M.; Ries, Richard K.
2017-01-01
Objective To determine if a contingency management intervention using the ethyl glucuronide (EtG) alcohol biomarker resulted in increased alcohol abstinence in outpatients with co-occurring serious mental illnesses. Secondary objectives were to determine if contingency management was associated with changes in heavy drinking, treatment attendance, drug use, cigarette smoking, psychiatric symptoms, and HIV-risk behavior. Method Seventy-nine (37% female, 44% non-white) outpatients with serious mental illness and alcohol dependence receiving treatment as usual completed a 4-week observation period and were randomized to 12-weeks of contingency management for EtG-negative urine samples and addiction treatment attendance, or reinforcement only for study participation. Contingency management included the variable magnitude of reinforcement “prize draw” procedure contingent on EtG-negative samples (<150 ng/mL) three times a week and weekly gift cards for outpatient treatment attendance. Urine EtG, drug test, and self-report outcomes were assessed during the 12-week intervention and 3-month follow-up periods. Results Contingency management participants were 3.1 times (95% CI: 2.2, 4.5) more likely to submit an EtG-negative urine test during the 12-week intervention period, attaining nearly 1.5 weeks of additional abstinence relative to controls. Contingency management participants had significantly lower mean EtG levels, reported less drinking and fewer heavy drinking episodes, and were more likely to submit stimulant-negative urine and smoking-negative breath samples, relative to controls. Differences in self-reported alcohol use were maintained at the 3-month follow-up. Conclusions This is the first randomized trial utilizing an accurate and validated biomarker (EtG) to demonstrate the efficacy of contingency management for alcohol dependence in outpatients with serious mental illness. PMID:28135843
McDonell, Michael G; Leickly, Emily; McPherson, Sterling; Skalisky, Jordan; Srebnik, Debra; Angelo, Frank; Vilardaga, Roger; Nepom, Jenny R; Roll, John M; Ries, Richard K
2017-04-01
The authors examined whether a contingency management intervention using the ethyl glucuronide (EtG) alcohol biomarker resulted in increased alcohol abstinence in outpatients with co-occurring serious mental illnesses. Secondary objectives were to determine whether contingency management was associated with changes in heavy drinking, treatment attendance, drug use, cigarette smoking, psychiatric symptoms, and HIV-risk behavior. Seventy-nine (37% female, 44% nonwhite) outpatients with serious mental illness and alcohol dependence receiving treatment as usual completed a 4-week observation period and were randomly assigned to 12 weeks of contingency management for EtG-negative urine samples and addiction treatment attendance, or reinforcement only for study participation. Contingency management included the variable magnitude of reinforcement "prize draw" procedure contingent on EtG-negative samples (<150 ng/mL) three times a week and weekly gift cards for outpatient treatment attendance. Urine EtG, drug test, and self-report outcomes were assessed during the 12-week intervention and 3-month follow-up periods. Contingency management participants were 3.1 times (95% CI=2.2-4.5) more likely to submit an EtG-negative urine test during the 12-week intervention period, attaining nearly 1.5 weeks of additional alcohol abstinence compared with controls. Contingency management participants had significantly lower mean EtG levels, reported less drinking and fewer heavy drinking episodes, and were more likely to submit stimulant-negative urine and smoking-negative breath samples, compared with controls. Differences in self-reported alcohol use were maintained at the 3-month follow-up. This is the first randomized trial utilizing an accurate and validated biomarker (EtG) to demonstrate the efficacy of contingency management for alcohol dependence in outpatients with serious mental illness.
Choi, In Ah; Park, Jin Kyun; Lee, Eun Young; Song, Yeong Wook; Lee, Eun Bong
2013-01-01
The accurate assessment of proteinuria is critical for the management of lupus nephritis. Measuring the protein to creatinine (P/C) ratio in random spot urine (RSU) samples has been introduced as an alternative to the 24-hour (24h) urine collection method. However, it remains unclear as to whether the RSU P/C ratio is reliable for assessing lupus nephritis (LN) in routine clinical practice. In total, 275 pairs of 24h urine and RSU samples from 102 patients with biopsy-proven LN were analysed. The correlation and concordance between the P/C ratios in the two sample types were assessed by Pearson or Spearman correlation and intra-class correlation coefficient (ICC) using mixed models for repeated measurements, respectively. The mean 24h urine P/C ratio was 3.2 ± 4.9. Overall, RSU P/C ratio correlated strongly with the 24h urine P/C ratio (r=0.944, p<0.001) with an excellent agreement (ICC=0.949, 95% confidence interval [CI]: 0.69-1.00). Subgroup analyses revealed that the correlation remained high in class II, III, IV, and V LN (rho=0.868, p<0.001; rho=0.649, p=0.007; r=0.945, p<0.001; and rho=0.900, p=0.001, respectively). The correlation between the 24h urine and RSU P/C ratio in the range of 0.5 to 3 was good (r=0.720, p<0.001) with ICC of 0.659 (95%CI 0.554-0.812). RSU P/C ratio ≥0.5 could predict 24h PCR ≥0.5 with 91.7% sensitivity and 70.2% specificity, whereas RSU P/C ratio ≥1.0 increased specificity up to 94.7%. The RSU P/C ratio is an excellent alternative to the 24 hour P/C ratio for assessing the presence of clinically significant proteinuria in LN. RSU P/C ratio >1.0 may prompt directly to a renal biopsy, whereas RSU P/C ratio between 0.5-1.0 should be followed by a confirmatory 24h urine collection.
Kolbach-Mandel, Ann M; Mandel, Neil S; Hoffmann, Brian R; Kleinman, Jack G; Wesson, Jeffrey A
2017-08-01
Many urine proteins are found in calcium oxalate stones, yet decades of research have failed to define the role of urine proteins in stone formation. This urine proteomic study compares the relative amounts of abundant urine proteins between idiopathic calcium oxalate stone forming and non-stone forming (normal) cohorts to identify differences that might correlate with disease. Random mid-morning urine samples were collected following informed consent from 25 stone formers and 14 normal individuals. Proteins were isolated from urine using ultrafiltration. Urine proteomes for each sample were characterized using label-free spectral counting mass spectrometry, so that urine protein relative abundances could be compared between the two populations. A total of 407 unique proteins were identified with the 38 predominant proteins accounting for >82% of all sample spectral counts. The most highly abundant proteins were equivalent in stone formers and normals, though significant differences were observed in a few moderate abundance proteins (immunoglobulins, transferrin, and epidermal growth factor), accounting for 13 and 10% of the spectral counts, respectively. These proteins contributed to a cationic shift in protein distribution in stone formers compared to normals (22% vs. 18%, p = 0.04). Our data showing only small differences in moderate abundance proteins suggest that no single protein controls stone formation. Observed increases in immunoglobulins and transferrin suggest increased inflammatory activity in stone formers, but cannot distinguish cause from effect in stone formation. The observed cationic shift in protein distribution would diminish protein charge stabilization, which could lead to protein aggregation and increased risk for crystal aggregation.
Lohiya, Ayush; Kapil, Arti; Gupta, Sanjeev Kumar; Misra, Puneet; Rai, Sanjay K.
2015-01-01
Background Despite world-wide evidence of increased antibiotic resistance, there is scarce data on antibiotic resistance in community settings. One of the reason being difficulty in collection of biological specimen (traditionally stool) in community from apparently healthy individuals. Hence, finding an alternative specimen that is easier to obtain in a community setting or in large scale surveys for the purpose, is crucial. We conducted this study to explore the feasibility of using urine samples for deriving community based estimates of antibiotic resistance and to estimate the magnitude of resistance among urinary isolates of Escherichia coli and Klebsiella pneumonia against multiple antibiotics in apparently healthy individuals residing in a rural community of Haryana, North India. Materials and Methods Eligible individuals were apparently healthy, aged 18 years or older. Using the health management information system (HMIS) of Ballabgarh Health Demographic Surveillance System (HDSS), sampling frame was prepared. Potential individuals were identified using simple random sampling. Random urine sample was collected in a sterile container and transported to laboratory under ambient condition. Species identification and antibiotic susceptibility testing for Enterobacteriaceae was done using Clinical Laboratory and Standards Institute (CLSI) 2012 guidelines. Multi-drug resistant (MDR) Enterobacteriaceae, Extended Spectrum Beta Lactamase (ESBL) producing Enterobacteriaceae, and Carbapenem producing Enterobacteriaceae (CRE) were identified from the urine samples. Results A total of 433 individuals participated in the study (non-response rate – 13.4%), out of which 58 (13.4%) were positive for Enterobacteriaceae, 8.1% for E. coli and 5.3% for K. pneumoniae. Resistance against penicillin (amoxicillin/ampicillin) for E. coli and K. pneumoniae was 62.8% and 100.0% respectively. Isolates resistant to co-trimoxazole were 5.7% and 0.0% respectively. None of the isolates were resistant to imipenem, and meropenem. Conclusion and recommendations It is feasible to use urine sample to study magnitude of antibiotic resistance in population based surveys. At community level, resistance to amoxicillin was considerable, negligible for co-trimoxazole, and to higher antibiotics including carbapenems. PMID:26393150
Dasgupta, Amitava; Wahed, Amer; Wells, Alice
2002-02-01
Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.
2012-09-01
Groups ...................18 Table 6. Urine Specific Gravity in the Ten-Day Duration Groups ...............................................19 Table 7...exposed rats were not consistently significant compared to control groups and were considered random due to small group sizes. In urine samples...sources. Alternative fuels may be developed by synthesis from simpler molecules (e.g., natural gas) or by refining from non-petroleum sources (e.g
2013-01-01
Background For clinicians, it is important to rely on accurate laboratory results for patient care and optimal use of health care resources. We sought to explore our observations that urine protein:creatinine ratios (PrCr) ≥30 mg/mmol are seen not infrequently associated with normal pregnancy outcome. Methods Urine samples were collected prospectively from 160 pregnant women attending high-risk maternity clinics at a tertiary care facility. Urinary protein was measured using a pyrocatechol violet assay and urinary creatinine by an enzymatic method on Vitros analysers. Maternal/perinatal outcomes were abstracted from hospital records. Results 91/233 (39.1%) samples had a PrCr ≥30 mg/mmol, especially when urinary creatinine concentration was <3 mM (94.1%) vs. ≥3 mM (16.4%) (p < 0.001). When using the last sample before delivery, 47/160 (29.4%) had a PrCr ≥30 mg/mmol in diluted urine vs. only 17/160 (15.4%) in more concentrated urine (p < 0.001); PrCr positive results were also more frequent among the 32 (20.0%) women with known normal pregnancy outcome (90.9% vs. 0) (p < 0.001). Using the same analyser, 0.12 g/L urinary protein was ‘detected’ in deionised water. Re-analysis of data from two cohorts revealed substantially less inflation of PrCr in dilute urine using a pyrogallol red assay. Conclusions Random urinary PrCr was overestimated in dilute urine when tested using a common pyrocatechol violet dye-based method. This effect was reduced in cohorts when pyrogallol red assays were used. False positive results can impact on diagnosis and patient care. This highlights the need for both clinical and laboratory quality improvement projects and standardization of laboratory protein measurement. PMID:23865673
Taheri, Masumeh; Mehrzad, Jalil; Mahmudy Gharaie, Mohamad Hosein; Afshari, Reza; Dadsetan, Ahmad; Hami, Shakiba
2016-04-01
Arsenic bioavailability in rock, soil and water resources is notoriously hazardous. Geogenic arsenic enters the body and adversely affects many biochemical processes in animals and humans, posing risk to public health. Chelpu is located in NE Iran, where realgar, orpiment and pyrite mineralization is the source of arsenic in the macroenvironment. Using cluster random sampling strategy eight rocks, 23 soils, 12 drinking water resources, 36 human urine and hair samples and 15 adult sheep urine and wool samples in several large-scale herds in the area were randomly taken for quantification of arsenic in rock/soil/water, wool/hair/urine. Arsenic levels in rock/soil/water and wool/hair/urine were measured using inductively coupled plasma spectroscopy and atomic absorption spectrophotometry, respectively. While arsenic levels in rocks, soils and water resources hazardously ranged 9.40-25,873.3 mg kg(-1), 7.10-1448.80 mg kg(-1) and 12-606 μg L(-1), respectively, arsenic concentrations in humans' hair and urine and sheep's wool and urine varied from 0.37-1.37 μg g(-1) and 9-271.4 μg L(-1) and 0.3-3.11 μg g(-1) and 29.1-1015 μg L(-1), respectively. Local sheep and human were widely sick and slightly anemic. Hematological examination of the inhabitants revealed that geogenic arsenic could harm blood cells, potentially resulting in many other hematoimmunological disorders including cancer. The findings warn widespread exposure of animals and human in this agroecologically and geopolitically important region (i.e., its proximity with Afghanistan, Pakistan and Turkmenistan) and give a clue on how arsenic could induce infectious and non-infectious diseases in highly exposed human/animals.
2010-01-01
Background Ingestion of cranberry (Vaccinium macrocarpon Ait.) has traditionally been utilized for prevention of urinary tract infections. The proanthocyanidins (PACs) in cranberry, in particular the A-type linkages have been implicated as important inhibitors of primarily P-fimbriated E. coli adhesion to uroepithelial cells. Additional experiments were required to investigate the persistence in urine samples over a broader time period, to determine the most effective dose per day and to determine if the urinary anti-adhesion effect following cranberry is detected within volunteers of different origins. Methods Two separate bioassays (a mannose-resistant hemagglutination assay and an original new human T24 epithelial cell-line assay) have assessed the ex-vivo urinary bacterial anti-adhesion activity on urines samples collected from 32 volunteers from Japan, Hungary, Spain and France in a randomized, double-blind versus placebo study. An in vivo Caenorhabditis elegans model was used to evaluate the influence of cranberry regimen on the virulence of E. coli strain. Results The results indicated a significant bacterial anti-adhesion activity in urine samples collected from volunteers that consumed cranberry powder compared to placebo (p < 0.001). This inhibition was clearly dose-dependent, prolonged (until 24 h with 72 mg of PAC) and increasing with the amount of PAC equivalents consumed in each cranberry powder regimen. An in vivo Caenorhabditis elegans model showed that cranberry acted against bacterial virulence: E. coli strain presented a reduced ability to kill worms after a growth in urines samples of patients who took cranberry capsules. This effect is particularly important with the regimen of 72 mg of PAC. Conclusions Administration of PAC-standardized cranberry powder at dosages containing 72 mg of PAC per day may offer some protection against bacterial adhesion and virulence in the urinary tract. This effect may offer a nyctohemeral protection. PMID:20398248
Islam, Md Rafiqul; Attia, John; Alauddin, Mohammad; McEvoy, Mark; McElduff, Patrick; Slater, Christine; Islam, Md Monirul; Akhter, Ayesha; d'Este, Catherine; Peel, Roseanne; Akter, Shahnaz; Smith, Wayne; Begg, Stephen; Milton, Abul Hasnat
2014-12-04
Early life exposure to inorganic arsenic may be related to adverse health effects in later life. However, there are few data on postnatal arsenic exposure via human milk. In this study, we aimed to determine arsenic levels in human milk and the correlation between arsenic in human milk and arsenic in mothers and infants urine. Between March 2011 and March 2012, this prospective study identified a total of 120 new mother-baby pairs from Kashiani (subdistrict), Bangladesh. Of these, 30 mothers were randomly selected for human milk samples at 1, 6 and 9 months post-natally; the same mother baby pairs were selected for urine sampling at 1 and 6 months. Twelve urine samples from these 30 mother baby pairs were randomly selected for arsenic speciation. Arsenic concentration in human milk was low and non-normally distributed. The median arsenic concentration in human milk at all three time points remained at 0.5 μg/L. In the mixed model estimates, arsenic concentration in human milk was non-significantly reduced by -0.035 μg/L (95% CI: -0.09 to 0.02) between 1 and 6 months and between 6 and 9 months. With the progression of time, arsenic concentration in infant's urine increased non-significantly by 0.13 μg/L (95% CI: -1.27 to 1.53). Arsenic in human milk at 1 and 6 months was not correlated with arsenic in the infant's urine at the same time points (r = -0.13 at 1 month and r = -0.09 at 6 month). Arsenite (AsIII), arsenate (AsV), monomethyl arsonic acid (MMA), dimethyl arsinic acid (DMA) and arsenobetaine (AsB) were the constituents of total urinary arsenic; DMA was the predominant arsenic metabolite in infant urine. We observed a low arsenic concentration in human milk. The concentration was lower than the World Health Organization's maximum permissible limit (WHO Permissible Limit 15 μg/kg-bw/week). Our findings support the safety of breastfeeding even in arsenic contaminated areas.
Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz
2010-05-15
The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). Copyright (c) 2010 Elsevier B.V. All rights reserved.
Determining the authenticity of athlete urine in doping control by DNA analysis.
Devesse, Laurence; Syndercombe Court, Denise; Cowan, David
2015-10-01
The integrity of urine samples collected from athletes for doping control is essential. The authenticity of samples may be contested, leading to the need for a robust sample identification method. DNA typing using short tandem repeats (STR) can be used for identification purposes, but its application to cellular DNA in urine has so far been limited. Here, a reliable and accurate method is reported for the successful identification of urine samples, using reduced final extraction volumes and the STR multiplex kit, Promega® PowerPlex ESI 17, with capillary electrophoretic characterisation of the alleles. Full DNA profiles were obtained for all samples (n = 20) stored for less than 2 days at 4 °C. The effect of different storage conditions on yield of cellular DNA and probability of obtaining a full profile were also investigated. Storage for 21 days at 4 °C resulted in allelic drop-out in some samples, but the random match probabilities obtained demonstrate the high power of discrimination achieved through targeting a large number of STRs. The best solution for long-term storage was centrifugation and removal of supernatant prior to freezing at -20 °C. The method is robust enough for incorporation into current anti-doping protocols, and was successfully applied to 44 athlete samples for anti-doping testing with 100% concordant typing. Copyright © 2015 John Wiley & Sons, Ltd.
Unreliable alcohol testing in a shipping safety programme.
Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn
2009-08-10
Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.
Hosaka, Miki; Inoue, Ryusuke; Satoh, Michihiro; Watabe, Daisuke; Hanazawa, Tomohiro; Ohkubo, Takayoshi; Asayama, Kei; Obara, Taku; Imai, Yutaka
2018-01-01
The aim of this study was to assess the effects of irbesartan alone and combined with amlodipine, efonidipine, or trichlormethiazide on blood pressure (BP) and urinary albumin (UA) excretion in hypertensive patients with microalbuminuria (30≤UA/creatinine (Cr) ratio [UACR] <300 mg/g Cr) and upper-normal microalbuminuria (10≤UACR<30 mg/g Cr). This randomized controlled trial enrolled 175 newly diagnosed and untreated hypertensive patients (home systolic blood pressure [SBP]≥135 mmHg; 10≤UACR<300 mg/g Cr of casual spot urine at the first visit to clinic). All patients were treated with irbesartan (week 0). Patients who failed to achieve home SBP ≤125 mmHg on 8-week irbesartan monotherapy (nonresponders, n = 115) were randomized into three additional drug treatment groups: trichlormethiazide (n = 42), efonidipine (n = 39), or amlodipine (n = 34). Irbesartan monotherapy decreased home SBP and first morning urine samples (morning UACR) for 8 weeks (p < 0.0001). At 8 weeks after randomization, all three additional drugs decreased home SBP (p < 0.0002) and trichlormethiazide significantly decreased morning UACR (p = 0.03). Amlodipine decreased morning UACR in patients with microalbuminuria based on casual spot urine samples (p = 0.048). However, multivariate analysis showed that only higher home SBP and UACR at week 8, but not any additional treatments, were significantly associated with UACR reduction between week 8 and week 16. In conclusion, crucial points of the effects of combination therapy on UACR were basal UACR and SBP levels. The effect of trichlormethiazide or amlodipine treatment in combination with irbesartan treatment on microalbuminuria needs to be reexamined based on a larger sample size after considering basal UACR and SBP levels.
Detection of Genital HPV Infection Using Urine Samples: a Population Based Study in India.
Sabeena, Sasidharanpillai; Bhat, Parvati; Kamath, Veena; Mathew, Mary; Aswathyraj, Sushama; Devadiga, Santhosha; Prabhu, Suresha; Hindol, Maity; Chameetachal, Akhil; Krishnan, Anjana; Arunkumar, Govindakarnavar
2016-01-01
Cervical cancer is the second commonest cancer among Indian women and its association with human papilloma virus (HPV) is well established. This preventable cancer accounts for the maximum number of cancer related deaths among rural Indian women. Unlike in developed countries there are no organized cervical cancer screening programmes in India due to lack of resources and manpower. To detect genital HPV infection using urine samples among asymptomatic rural women in the age group of 18-65 years. The study area chosen was Perdoor village in Udupi Taluk, Karnataka State and all the women in the age group of 18-65 years formed the study cohort. A cross sectional study was conducted by house visits and 1,305 women were enrolled in the study. After taking written informed consent a data sheet was filled and early stream random urine samples were collected, transported to a laboratory at 4OC and aliquoted. Samples were tested using nested HPV PCR with PGMY09/11 and GP5+/6+ primers. Positive cases were genotyped by sequence analysis. Study participants included 1,134 sexually active and 171 unmarried women with a mean age at marriage of 22.1 (SD=3.9) years. Study area showed high female literacy rate of 86.6%. Five urine samples tested positive for HPV DNA (0.4%). We found very low genital HPV infection rate among women from monogamous community. This is the first major population based study carried out among asymptomatic rural women to detect genital HPV infectio from Karnataka using urine samples.
Bladder cancer biomarker discovery using global metabolomic profiling of urine.
Wittmann, Bryan M; Stirdivant, Steven M; Mitchell, Matthew W; Wulff, Jacob E; McDunn, Jonathan E; Li, Zhen; Dennis-Barrie, Aphrihl; Neri, Bruce P; Milburn, Michael V; Lotan, Yair; Wolfert, Robert L
2014-01-01
Bladder cancer (BCa) is a common malignancy worldwide and has a high probability of recurrence after initial diagnosis and treatment. As a result, recurrent surveillance, primarily involving repeated cystoscopies, is a critical component of post diagnosis patient management. Since cystoscopy is invasive, expensive and a possible deterrent to patient compliance with regular follow-up screening, new non-invasive technologies to aid in the detection of recurrent and/or primary bladder cancer are strongly needed. In this study, mass spectrometry based metabolomics was employed to identify biochemical signatures in human urine that differentiate bladder cancer from non-cancer controls. Over 1000 distinct compounds were measured including 587 named compounds of known chemical identity. Initial biomarker identification was conducted using a 332 subject sample set of retrospective urine samples (cohort 1), which included 66 BCa positive samples. A set of 25 candidate biomarkers was selected based on statistical significance, fold difference and metabolic pathway coverage. The 25 candidate biomarkers were tested against an independent urine sample set (cohort 2) using random forest analysis, with palmitoyl sphingomyelin, lactate, adenosine and succinate providing the strongest predictive power for differentiating cohort 2 cancer from non-cancer urines. Cohort 2 metabolite profiling revealed additional metabolites, including arachidonate, that were higher in cohort 2 cancer vs. non-cancer controls, but were below quantitation limits in the cohort 1 profiling. Metabolites related to lipid metabolism may be especially interesting biomarkers. The results suggest that urine metabolites may provide a much needed non-invasive adjunct diagnostic to cystoscopy for detection of bladder cancer and recurrent disease management.
Urinary Volatile Organic Compounds for the Detection of Prostate Cancer
Khalid, Tanzeela; Aggio, Raphael; White, Paul; De Lacy Costello, Ben; Persad, Raj; Al-Kateb, Huda; Jones, Peter; Probert, Chris S.; Ratcliffe, Norman
2015-01-01
The aim of this work was to investigate volatile organic compounds (VOCs) emanating from urine samples to determine whether they can be used to classify samples into those from prostate cancer and non-cancer groups. Participants were men referred for a trans-rectal ultrasound-guided prostate biopsy because of an elevated prostate specific antigen (PSA) level or abnormal findings on digital rectal examination. Urine samples were collected from patients with prostate cancer (n = 59) and cancer-free controls (n = 43), on the day of their biopsy, prior to their procedure. VOCs from the headspace of basified urine samples were extracted using solid-phase micro-extraction and analysed by gas chromatography/mass spectrometry. Classifiers were developed using Random Forest (RF) and Linear Discriminant Analysis (LDA) classification techniques. PSA alone had an accuracy of 62–64% in these samples. A model based on 4 VOCs, 2,6-dimethyl-7-octen-2-ol, pentanal, 3-octanone, and 2-octanone, was marginally more accurate 63–65%. When combined, PSA level and these four VOCs had mean accuracies of 74% and 65%, using RF and LDA, respectively. With repeated double cross-validation, the mean accuracies fell to 71% and 65%, using RF and LDA, respectively. Results from VOC profiling of urine headspace are encouraging and suggest that there are other metabolomic avenues worth exploring which could help improve the stratification of men at risk of prostate cancer. This study also adds to our knowledge on the profile of compounds found in basified urine, from controls and cancer patients, which is useful information for future studies comparing the urine from patients with other disease states. PMID:26599280
Postal urine specimens: are they a feasible method for genital chlamydial infection screening?
Macleod, J; Rowsell, R; Horner, P; Crowley, T; Caul, E O; Low, N; Smith, G D
1999-01-01
BACKGROUND: A United Kingdom (UK) screening programme for Chlamydia trachomatis has recently been announced. Pilot projects involving the opportunistic testing of women attending health facilities are due to commence in several sites. There is a danger that this approach will fail to obtain adequate population coverage. The alternative--true systematic population screening--is generally assumed to be unfeasible. Studies in Denmark using postal urine specimens have challenged this assumption. No such studies have been reported from the UK. AIM: To assess the potential of urine specimens sent by post as the basis for a UK population screening strategy for genital chlamydial infection. METHOD: Two hundred patients (100 men, 100 women) aged 18 to 45 years were randomly sampled from the list of one urban group practice. Subjects were mailed an explanatory letter, a urine sample container, a sexual lifestyle questionnaire, and a prepaid return envelope. Non-responders were contacted by telephone; persistent non-responders were visited at home. Samples were tested for Chlamydia by DNA amplification and enzyme immunoassay. RESULTS: Sixty-four (32%) subjects were no longer living at their GP registered address. Of the remaining 136, 126 (93%) responded to the survey and 113 (83%) accepted the request for a urine sample and completed a questionnaire. Acceptance rates were similar for men and women and across age groups. Four samples (3%) were Chlamydia positive. CONCLUSION: Home mailed urine specimen collection in conjunction with a self-completed postal questionnaire is feasible. This could provide a viable basis both for determining population Chlamydia prevalence and for a UK Chlamydia population screening strategy. Overall cost effectiveness of such a strategy will depend on the cost of the test used. Comparative performance characteristics of the different currently available tests in this setting have yet to be fully determined. PMID:10562745
Effects of incentives for naltrexone adherence on opiate abstinence in heroin-dependent adults
Jarvis, Brantley P.; Holtyn, August F.; DeFulio, Anthony; Dunn, Kelly E.; Everly, Jeffrey J.; Leoutsakos, Jeannie-Marie S.; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Silverman, Kenneth
2017-01-01
Aim To test whether an incentive-based intervention that increased adherence to naltrexone also increased opiate abstinence. Design Post-hoc combined analysis of three earlier randomized controlled trials that individually showed that incentives for adherence to oral and to extended-release injection naltrexone dosing schedules increased naltrexone adherence but not opiate abstinence. Setting Outpatient therapeutic workplace in Baltimore, MD, USA. Participants 140 unemployed heroin-dependent adults participating from 2006–2010. Interventions Participants were hired in a model workplace for 26 weeks and randomized to a Contingency (n=72) or Prescription (n=68) group. Both groups were offered naltrexone. Contingency participants were required to take scheduled doses of naltrexone in order to work and earn wages. Prescription participants could earn wages independent of naltrexone adherence. Measures Thrice-weekly and monthly urine samples tested for opiates and cocaine and measures of naltrexone adherence (percentage of monthly urine samples positive for naltrexone or percentage of scheduled injections received). All analyses included prerandomization attendance, opiate use, and cocaine use as covariates. Additional analyses controlled for cocaine use and naltrexone adherence during the intervention. Findings Contingency participants had more opiate abstinence than Prescription participants (68.1% vs. 52.9% opiate-negative thrice-weekly urine samples, respectively; and 71.9% vs. 61.7% opiate-negative monthly urine samples, respectively) based on initial analyses (thrice-weekly samples, OR = 3.3, 95% CI = 1.7–6.5, p < .01; monthly samples, OR = 2.6, 95% CI = 1.0–7.1, p = .06) and on analyses that controlled for cocaine use (thrice-weekly samples, OR = 3.9, 95% CI = 3.3–4.5, p < .01; monthly samples, OR = 3.4, 95% CI = 1.1–11.1, p =.04), which was high and associated with opiate use. The difference in opiate abstinence rates between Contingency participants and Prescription participants was reduced when controlling for naltrexone adherence (monthly samples, OR = 1.1, 95% CI = 0.7–1.7, p = .84). Conclusions Incentives for naltrexone adherence increase opiate abstinence in heroin-dependent adults, an effect that appears to be due to increased naltrexone adherence produced by the incentives. PMID:27936293
Urine sodium excretion increased slightly among U.S. adults between 1988 and 2010.
Pfeiffer, Christine M; Hughes, Jeffery P; Cogswell, Mary E; Burt, Vicki L; Lacher, David A; Lavoie, Donna J; Rabinowitz, Daniel J; Johnson, Clifford L; Pirkle, James L
2014-05-01
Little information is available on temporal trends in sodium intake in the U.S. population using urine sodium excretion as a biomarker. Our aim was to assess 1988-2010 trends in estimated 24-h urine sodium (24hUNa) excretion among U.S. adults (age 20-59 y) participating in the cross-sectional NHANES. We used subsamples from a 1988-1994 convenience sample, a 2003-2006 one-third random sample, and a 2010 one-third random sample to comply with resource constraints. We estimated 24hUNa excretion from measured sodium concentrations in spot urine samples by use of calibration equations (for men and women) derived from the International Cooperative Study on Salt, Other Factors, and Blood Pressure study. Estimated 24hUNa excretion increased over the 20-y period [1988-1994, 2003-2006, and 2010; means ± SEMs (n): 3160 ± 38.4 mg/d (1249), 3290 ± 29.4 mg/d (1235), and 3290 ± 44.4 mg/d (525), respectively; P-trend = 0.022]. We observed significantly higher mean estimated 24hUNa excretion in each survey period (P < 0.001) for men compared with women (31-33%) and for persons with a higher body mass index (BMI; 32-35% for obese vs. normal weight) or blood pressure (17-26% for hypertensive vs. normal blood pressure). After adjusting for age, sex, and race-ethnicity, temporal trends in mean estimated 24hUNa excretion remained significant (P-trend = 0.004). We observed no temporal trends in mean estimated 24hUNa excretion among BMI subgroups, nor after adjusting for BMI. Although several limitations apply to this analysis (the use of a convenience sample in 1988-1994 and using estimated 24hUNa excretion as a biomarker of sodium intake), these first NHANES data suggest that mean estimated 24hUNa excretion increased slightly in U.S. adults over the past 2 decades, and this increase may be explained by a shift in the distribution of BMI.
Skopp, Gisela; Pötsch, Lucia
2004-01-01
Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied using spiked urine to elucidate the results obtained from authentic samples. In authentic urine samples, the initial pH ranged from 5.1 to 8.8. The glucuronide was found to be highly labile at a storage temperature of 4 degrees C and above. Initially, 18 urine samples tested positive for THCCOOH. After 2 days storage at 20 degrees C, THCCOOH was detectable in a further 4 samples, and 7 more samples tested positive for THCCOOH (5-81 ng/mL) after 15 days. Depending on time and temperature, the glucuronide concentration decreased, resulting in an increase of THCCOOH concentration. However, a loss in mean total THCCOOH concentration was found, which was significantly higher in deteriorated samples than in samples without signs of deterioration after 15 days of storage at 20 degrees C. In the drug-free urine sample separately spiked with THCCOOglu or THCCOOH, the investigations on the stability of the target analytes at various pH values revealed that THCCOOH was stable at pH 5.0. At higher pH values, its concentration slightly decreased with time, and about 69% of the initial THCCOOH concentration was still present at pH 8.0 on day 5. THCCOOglu concentrations rapidly decreased with increasing pH value. For example, only 72% of the initial THCCOOglu concentration could be detected at pH 5.0 on day 1. Degradation of the glucuronide resulted in formation of THCCOOH, which was observed even at pH 5.0. In light of the present findings, advanced forensic interpretations based on the presence of THCCOOH or the pattern of THCCOOH and THCCOOglu in stored urine samples seems questionable.
Mizéhoun-Adissoda, Carmelle; Houehanou, Corine; Chianéa, Thierry; Dalmay, François; Bigot, André; Preux, Pierre-Marie; Bovet, Pascal; Houinato, Dismand; Desport, Jean-Claude
2016-07-01
The 24-hour urine collection method is considered the gold standard for the estimation of ingested potassium and sodium. Because of the impracticalities of collecting all urine over a 24-hour period, spot urine is often used for epidemiological investigations. This study aims to assess the agreement between spot urine and 24-hour urine measurements to determine sodium and potassium intake. A total of 402 participants aged 25 to 64 years were randomly selected in South Benin. Spot urine was taken during the second urination of the day. Twenty-four-hour urine was also collected. Samples (2-mL) were taken and then stored at -20°C. The analysis was carried out using potentiometric dosage. The agreement between spot urine and 24-hour urine measurements was established using Bland-Altman plots. A total of 354 results were analyzed. Daily sodium chloride and potassium chloride urinary excretion means were 10.2±4.9 g/24 h and 2.9±1.4 g/24 h, respectively. Estimated daily sodium chloride and potassium chloride means from the spot urine were 10.7±7.0 g/24 h and 3.9±2.1 g/24 h, respectively. Concordance coefficients were 0.61 at d=-0.5 g, (d±2SD=-11 g and 10.1 g) for sodium chloride and 0.61 at d=-1 g, (d±2SD=-3.8 g and 1.8 g) for potassium chloride. Spot urine method is acceptable for estimating 24-hour urinary sodium and potassium excretion to assess sodium and potassium intake in a black population. However, the confidence interval for the mean difference, which is too large, makes the sodium chloride results inadmissible at a clinical level. © 2015 Wiley Periodicals, Inc.
A comparison of drug use in driver fatalities and similarly exposed drivers
DOT National Transportation Integrated Search
1977-07-01
Author's abstract: Crash information, urine, blood and bile samples from 900 fatally injured drivers were collected by medical examiners in 22 areas of the country. Randomly selected living drivers were interviewed at times and places of recent fatal...
Hydration status in adolescent runners: pre and post training
NASA Astrophysics Data System (ADS)
Ashadi, K.; Mirza, D. N.; Siantoro, G.
2018-01-01
The adequacy of body fluids is important for athletes in supporting performance. The purpose of this research was to determine the hydration status of athletes before and after training. The study was a qualitative descriptive by using random sampling. All athletes were trained for approximately 60 minutes. And they were asked to analyze their body fluid pattern routinely. Data were obtained through urine color measurement. The urinary was taken at pre and post training and was immediately assessed in the afternoon. Based on pre-training urine samples, a mean of urine color scale was 3.1 point. It meant that only 31.2% of the athletes were in dehydrated condition. However, after exercising, urine color index showed scale 4.1. And 62.5% of the athletes experienced dehydration. The results showed that there was a significant change in hydration level before and after training. It can be concluded that training for a long time increases the risk of dehydration. It is important for athletes to meet the needs of body fluids in order to avoid functional impairment in the body during sports activities.
Wolrath, H; Ståhlbom, B; Hallén, A; Forsum, U
2005-01-01
The smell of rotten fish is one of the characteristics of bacterial vaginosis (BV), and is due to trimethylamine (TMA). Trimethylamine can be found in human urine, although most of it occurs as the nonvolatile oxide (TMAO) form. The fraction TMA/TMAO can be expected to be the same in different body fluids if no local production of TMA occurs. In women with BV, TMAO in the vaginal fluid is expected to be chemically reduced by the local bacterial flora to the much more odorous TMA. We have therefore studied the local vaginal production of TMA in vaginal secretion compared to the general TMA-TMAO metabolism that was measured in urine using gas chromatography. Both vaginal fluid and random urine samples were collected from women, with and without BV, attending a Swedish clinic for sexually transmitted diseases, and these samples were analyzed for TMA and TMAO. The results show that a local production of TMA occurs in the vagina that is not part of the general metabolism of TMA-TMAO.
Comparison of urine analysis using manual and sedimentation methods.
Kurup, R; Leich, M
2012-06-01
Microscopic examination of urine sediment is an essential part in the evaluation of renal and urinary tract diseases. Traditionally, urine sediments are assessed by microscopic examination of centrifuged urine. However the current method used by the Georgetown Public Hospital Corporation Medical Laboratory involves uncentrifuged urine. To encourage high level of care, the results provided to the physician must be accurate and reliable for proper diagnosis. The aim of this study is to determine whether the centrifuge method is more clinically significant than the uncentrifuged method. In this study, a comparison between the results obtained from centrifuged and uncentrifuged methods were performed. A total of 167 urine samples were randomly collected and analysed during the period April-May 2010 at the Medical Laboratory, Georgetown Public Hospital Corporation. The urine samples were first analysed microscopically by the uncentrifuged, and then by the centrifuged method. The results obtained from both methods were recorded in a log book. These results were then entered into a database created in Microsoft Excel, and analysed for differences and similarities using this application. Analysis was further done in SPSS software to compare the results using Pearson ' correlation. When compared using Pearson's correlation coefficient analysis, both methods showed a good correlation between urinary sediments with the exception of white bloods cells. The centrifuged method had a slightly higher identification rate for all of the parameters. There is substantial agreement between the centrifuged and uncentrifuged methods. However the uncentrifuged method provides for a rapid turnaround time.
Collection fluid helps preservation in voided urine cytology.
Raistrick, J; Shambayati, B; Dunsmuir, W
2008-04-01
Degenerative change caused by delay in processing contributes to false-negative and false-positive diagnosis of urothelial carcinoma in cytology. The aim of the study was to see if the use of a collection fluid for urine samples made a significant difference to urine cytology diagnosis, and if one was better suited for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analysing the preservation and degeneration of cells in urine samples, as was the routine preparation which did not use a collection fluid. In the design study 50 voided urine specimens were taken at random from the hospital haematuria clinic. Three commercially available collection fluids cytolyt, cytospin and cytoRich Blue and the hospital's routine conventional preparation of urine were compared. The degree of degeneration, and so preservation, was assessed by a table of chosen criteria; then ranked and analysed by Friedman's nonparametric test, at P = 0.05. A second table showing the cell content of each slide was also made. These showed no significant diagnostic difference between the collection fluids, but there was a significant difference between the collection fluids and the routine preparation. Minor differences that do not affect diagnosis, such as crystals and ghost red blood cells, were noted in cytospin and cytoRich Blue. It is recommended that a collection fluid is used. This choice should be made after health and safety issues and cost are considered.
Rasmussen, A; Frimodt-Møller, N; Espersen, F; Roed, M; Frimodt-Møller, C
1996-08-01
To compare three different urine metering systems for their ability to prevent retrograde contamination in an in vitro model of a closed urinary drainage system and for qualities important to their practical handling in a clinical setting. Using three urine-meters (the Braun Ureofix 511, the Kendall Curity 4000 and the Unoplast Unometer 500) the in vitro model was constantly flushed with a solution of Mueller-Hinton broth diluted with saline. On the first day, the urine collecting bag was inoculated with 10(8) cells of Pseudomonas aeruginosa. The system was operated for 12 days with daily sampling of the model bladder to detect any contamination. After 12 days the experiment was stopped and sampling performed at various locations, including the urine-meter and the tubing. Nine of each type of urine-meter were tested, i.e. three in three different experiments. In the clinical study, 45 patients were randomized to each of the three urine-meters and the nurses attending them were asked to complete a questionnaire on the practical handling of the urine-meters. When the urine-meters was omitted from the model system, the 'bladder' became contaminated with the test bacteria within 3 days. None of the nine Unometer 500 systems became contaminated, compared with four of each of the other two systems (P < 0.05). In clinical use, the Unometer 500 and Ureofix 511 were easier to suspend and empty than was the Curity 4000. The Unometer 500 was significantly easier to handle when the collecting bag was emptied. Urine-meters can prevent retrograde contamination in a closed bladder-drainage model, but the degree of prevention depends upon the type of urine-meter. In daily practice, there were differences in the ease of suspension of the systems and in the emptying of the urine-meter and collecting bag.
NASA Astrophysics Data System (ADS)
Weng, Shizhuang; Dong, Ronglu; Zhu, Zede; Zhang, Dongyan; Zhao, Jinling; Huang, Linsheng; Liang, Dong
2018-01-01
Conventional Surface-Enhanced Raman Spectroscopy (SERS) for fast detection of drugs in urine on the portable Raman spectrometer remains challenges because of low sensitivity and unreliable Raman signal, and spectra process with manual intervention. Here, we develop a novel detection method of drugs in urine using chemometric methods and dynamic SERS (D-SERS) with mPEG-SH coated gold nanorods (GNRs). D-SERS combined with the uniform GNRs can obtain giant enhancement, and the signal is also of high reproducibility. On the basis of the above advantages, we obtained the spectra of urine, urine with methamphetamine (MAMP), urine with 3, 4-Methylenedioxy Methamphetamine (MDMA) using D-SERS. Simultaneously, some chemometric methods were introduced for the intelligent and automatic analysis of spectra. Firstly, the spectra at the critical state were selected through using K-means. Then, the spectra were proposed by random forest (RF) with feature selection and principal component analysis (PCA) to develop the recognition model. And the identification accuracy of model were 100%, 98.7% and 96.7%, respectively. To validate the effect in practical issue further, the drug abusers'urine samples with 0.4, 3, 30 ppm MAMP were detected using D-SERS and identified by the classification model. The high recognition accuracy of > 92.0% can meet the demand of practical application. Additionally, the parameter optimization of RF classification model was simple. Compared with the general laboratory method, the detection process of urine's spectra using D-SERS only need 2 mins and 2 μL samples volume, and the identification of spectra based on chemometric methods can be finish in seconds. It is verified that the proposed approach can provide the accurate, convenient and rapid detection of drugs in urine.
Poole, Angela C.; Pischel, Lauren; Ley, Catherine; Suh, Gina; Goodrich, Julia K.; Haggerty, Thomas D.; Ley, Ruth E.
2016-01-01
ABSTRACT Commonly prescribed antibiotics are known to alter human microbiota. We hypothesized that triclosan and triclocarban, components of many household and personal care products (HPCPs), may alter the oral and gut microbiota, with potential consequences for metabolic function and weight. In a double-blind, randomized, crossover study, participants were given triclosan- and triclocarban (TCS)-containing or non-triclosan/triclocarban (nTCS)-containing HPCPs for 4 months and then switched to the other products for an additional 4 months. Blood, stool, gingival plaque, and urine samples and weight data were obtained at baseline and at regular intervals throughout the study period. Blood samples were analyzed for metabolic and endocrine markers and urine samples for triclosan. The microbiome in stool and oral samples was then analyzed. Although there was a significant difference in the amount of triclosan in the urine between the TCS and nTCS phases, no differences were found in microbiome composition, metabolic or endocrine markers, or weight. Though this study was limited by the small sample size and imprecise administration of HPCPs, triclosan at physiologic levels from exposure to HPCPs does not appear to have a significant or important impact on human oral or gut microbiome structure or on a panel of metabolic markers. IMPORTANCE Triclosan and triclocarban are commonly used commercial microbicides found in toothpastes and soaps. It is unknown what effects these chemicals have on the human microbiome or on endocrine function. From this randomized crossover study, it appears that routine personal care use of triclosan and triclocarban neither exerts a major influence on microbial communities in the gut and mouth nor alters markers of endocrine function in humans. PMID:27303746
McKay, James R; Knepper, Cheryl; Deneke, Erin; O'Reilly, Christopher; DuPont, Robert L
2016-08-01
Physician health programs (PHPs) generate high rates of sustained abstinence in addicted physicians, through a combination of formal treatment, self-help involvement, regular monitoring via random urine toxicology tests, and powerful incentives generated by the threat of losing one's medical license. Recently, Caron Treatment Centers developed a new continuing care intervention, "My First Year of Recovery" (MyFYR), which is modeled after PHPs but provides extended recovery support to a broader segment of those with substance use disorders. This paper presents initial outcome data from MyFYR. MyFYR features frequent outcomes monitoring via urine toxicology tests, and also includes a web-based social platform to coordinate efforts of recovery coaches, family members, and others (e.g., employers, probation officers). Participants were the first 198 clients who enrolled in MyFYR after participating in residential treatment at Caron. Substance use outcomes were determined by a combination of urine toxicology tests, client self-report, and information from family members obtained during a 12-month period following entry into MyFYR. Clients in MyFYR provided 70% of scheduled urine samples, for an average of 16.4 urine samples per client. Only 4.1% of the samples tested positive for alcohol or any drug. As determined by urine toxicology and client and family reports, 54% of the participants had some use of alcohol or drugs during the follow-up. Of these relapsed clients, 70.1% were retained or re-engaged in MyFYR, and of these, half were able to re-establish abstinence of two months duration or more, as documented by urine toxicology. These initial results are extremely promising, as they document high rates of sustained participation in urine drug test monitoring and positive outcome in clients not under the threat of losing a professional license or incarceration. Copyright © 2016 Elsevier Inc. All rights reserved.
Sadjadi, Seyed-Ali; Jaipaul, Navin
2010-09-07
Quantification of proteinuria is usually predicated upon 24-hour urine collection. Multiple factors influence urine collection and the rate of protein and creatinine excretion. Urine collection is often incomplete, and therefore creatinine and protein excretion rates are underestimated. A random urine protein-creatinine (P-C) ratio has been shown over the years to be a reliable alternative to the 24-hour collection for detection and follow up of proteinuria. However, urine protein excretion may be influenced by physical activity. We studied 48 patients with proteinuria and varying levels of physical activity to determine the correlation between the measures of urine protein excretion. The correlation coefficient (r) between 24-hour urine total protein and random urine P-C ratio was 0.75 (P < 0.01) in the overall study population, but varied according to the level of proteinuria and physical activity in a stratified analysis: r = 0.99 (P < 0.001) and r = 0.95 (P < 0.01) in bedridden patients; r = 0.44 (P = not significant [NS]) and r = 0.54 (P = NS) in semiactive patients; and r = 0.44 (P = NS) and r = 0.58 (P < 0.05) in active patients with nephrotic- (>3500 mg/day) and non-nephrotic (<3500 mg/day) range proteinuria, respectively. The correlation appeared to be stronger between random urine and 24-hour urine P-C ratio for the overall study population (r = 0.84; P < 0.001), and when stratified according to the level of proteinuria and physical activity: r = 0.99 (P < 0.001) and r = 0.92 (P < 0.01) in bedridden patients; r = 0.61 (P = NS) and r = 0.54 (P = NS) in semiactive patients; and r = 0.64 (P < 0.02) and r = 0.52 (P < 0.05) in active patients with nephrotic and non-nephrotic range proteinuria, respectively. We conclude that the random urine P-C ratio is a reliable and practical way of estimating and following proteinuria, but its precision and accuracy may be affected by the level of patient physical activity.
Sadjadi, Seyed-Ali; Jaipaul, Navin
2010-01-01
Quantification of proteinuria is usually predicated upon 24-hour urine collection. Multiple factors influence urine collection and the rate of protein and creatinine excretion. Urine collection is often incomplete, and therefore creatinine and protein excretion rates are underestimated. A random urine protein-creatinine (P-C) ratio has been shown over the years to be a reliable alternative to the 24-hour collection for detection and follow up of proteinuria. However, urine protein excretion may be influenced by physical activity. We studied 48 patients with proteinuria and varying levels of physical activity to determine the correlation between the measures of urine protein excretion. The correlation coefficient (r) between 24-hour urine total protein and random urine P-C ratio was 0.75 (P < 0.01) in the overall study population, but varied according to the level of proteinuria and physical activity in a stratified analysis: r = 0.99 (P < 0.001) and r = 0.95 (P < 0.01) in bedridden patients; r = 0.44 (P = not significant [NS]) and r = 0.54 (P = NS) in semiactive patients; and r = 0.44 (P = NS) and r = 0.58 (P < 0.05) in active patients with nephrotic- (>3500 mg/day) and non-nephrotic (<3500 mg/day) range proteinuria, respectively. The correlation appeared to be stronger between random urine and 24-hour urine P-C ratio for the overall study population (r = 0.84; P < 0.001), and when stratified according to the level of proteinuria and physical activity: r = 0.99 (P < 0.001) and r = 0.92 (P < 0.01) in bedridden patients; r = 0.61 (P = NS) and r = 0.54 (P = NS) in semiactive patients; and r = 0.64 (P < 0.02) and r = 0.52 (P < 0.05) in active patients with nephrotic and non-nephrotic range proteinuria, respectively. We conclude that the random urine P-C ratio is a reliable and practical way of estimating and following proteinuria, but its precision and accuracy may be affected by the level of patient physical activity. PMID:20856681
Phthalate Metabolites, Consumer Habits and Health Effects
Wallner, Peter; Kundi, Michael; Hohenblum, Philipp; Scharf, Sigrid; Hutter, Hans-Peter
2016-01-01
Phthalates are multifunctional chemicals used in a wide variety of consumer products. The aim of this study was to investigate whether levels of urinary phthalate metabolites in urine samples of Austrian mothers and their children were associated with consumer habits and health indicators. Within an Austrian biomonitoring survey, urine samples from 50 mother-child pairs of five communities (two-stage random stratified sampling) were analysed. The concentrations of 14 phthalate metabolites were determined, and a questionnaire was administered. Monoethyl phthalate (MEP), mono-n-butyl phthalate (MnBP), mono-isobutyl phthalate (MiBP), monobenzyl phthalate (MBzP), mono-(2-ethylhexyl) phthalate (MEHP), mono-(2-ethyl-5-hydroxyhexyl) phthalate (5OH-MEHP), mono-(2-ethyl-5-oxohexyl) phthalate (5oxo-MEHP), mono-(5-carboxy-2-ethylpentyl) phthalate (5cx-MEPP), and 3-carboxy-mono-propyl phthalate (3cx-MPP) could be quantified in the majority of samples. Significant correlations were found between the use of hair mousse, hair dye, makeup, chewing gum, polyethylene terephthalate (PET) bottles and the diethyl phthalate (DEP) metabolite MEP. With regard to health effects, significant associations of MEP in urine with headache, repeated coughing, diarrhoea, and hormonal problems were observed. MBzP was associated with repeated coughing and MEHP was associated with itching. PMID:27428989
Phthalate Metabolites, Consumer Habits and Health Effects.
Wallner, Peter; Kundi, Michael; Hohenblum, Philipp; Scharf, Sigrid; Hutter, Hans-Peter
2016-07-15
Phthalates are multifunctional chemicals used in a wide variety of consumer products. The aim of this study was to investigate whether levels of urinary phthalate metabolites in urine samples of Austrian mothers and their children were associated with consumer habits and health indicators. Within an Austrian biomonitoring survey, urine samples from 50 mother-child pairs of five communities (two-stage random stratified sampling) were analysed. The concentrations of 14 phthalate metabolites were determined, and a questionnaire was administered. Monoethyl phthalate (MEP), mono-n-butyl phthalate (MnBP), mono-isobutyl phthalate (MiBP), monobenzyl phthalate (MBzP), mono-(2-ethylhexyl) phthalate (MEHP), mono-(2-ethyl-5-hydroxyhexyl) phthalate (5OH-MEHP), mono-(2-ethyl-5-oxohexyl) phthalate (5oxo-MEHP), mono-(5-carboxy-2-ethylpentyl) phthalate (5cx-MEPP), and 3-carboxy-mono-propyl phthalate (3cx-MPP) could be quantified in the majority of samples. Significant correlations were found between the use of hair mousse, hair dye, makeup, chewing gum, polyethylene terephthalate (PET) bottles and the diethyl phthalate (DEP) metabolite MEP. With regard to health effects, significant associations of MEP in urine with headache, repeated coughing, diarrhoea, and hormonal problems were observed. MBzP was associated with repeated coughing and MEHP was associated with itching.
Buprenorphine implants for treatment of opioid dependence: a randomized controlled trial.
Ling, Walter; Casadonte, Paul; Bigelow, George; Kampman, Kyle M; Patkar, Ashwin; Bailey, Genie L; Rosenthal, Richard N; Beebe, Katherine L
2010-10-13
Limitations of existing pharmacological treatments for opioid dependence include low adherence, medication diversion, and emergence of withdrawal symptoms. To determine the efficacy of buprenorphine implants that provide a low, steady level of buprenorphine over 6 months for the treatment of opioid dependence. A randomized, placebo-controlled, 6-month trial conducted at 18 sites in the United States between April 2007 and June 2008. One hundred sixty-three adults, aged 18 to 65 years, diagnosed with opioid dependence. One hundred eight were randomized to receive buprenorphine implants and 55 to receive placebo implants. After induction with sublingual buprenorphine-naloxone tablets, patients received either 4 buprenorphine implants (80 mg per implant) or 4 placebo implants. A fifth implant was available if a threshold for rescue use of sublingual buprenorphine-naloxone treatment was exceeded. Standardized individual drug counseling was provided to all patients. The percentage of urine samples negative for illicit opioids for weeks 1 through 16 and for weeks 17 through 24. The buprenorphine implant group had significantly more urine samples negative for illicit opioids during weeks 1 through 16 (P = .04). Patients with buprenorphine implants had a mean percentage of urine samples that tested negative for illicit opioids across weeks 1 through 16 of 40.4% (95% confidence interval [CI], 34.2%-46.7%) and a median of 40.7%; whereas those in the placebo group had a mean of 28.3% (95% CI, 20.3%-36.3%) and a median of 20.8%. A total of 71 of 108 patients (65.7%) who received buprenorphine implants completed the study vs 17 of 55 (30.9%) who received placebo implants (P < .001). Those who received buprenorphine implants also had fewer clinician-rated (P <.001) and patient-rated (P = .004) withdrawal symptoms, had lower patient ratings of craving (P <.001), and experienced a greater change on clinician global ratings of severity of opioid dependence (P<.001) and on the clinician global ratings of improvement (P < .001) than those who received placebo implants. Minor implant site reactions were the most common adverse events: 61 patients (56.5%) in the buprenorphine group and 29 (52.7%) in the placebo group. Among persons with opioid dependence, the use of buprenorphine implants compared with placebo resulted in less opioid use over 16 weeks as assessed by urine samples. clinicaltrials.gov Identifier: NCT00447564.
Wang, H; Zhao, L; Xi, Y; Sun, N
2015-06-01
24-h urine sodium excretion is considered the most reliable method to evaluate the salt intakes. However, this method is cumbersome. So we want to develop formulas to estimate 24-h urinary sodium excretion using spot urinary samples in Chinese hypertensive population and explore the application value of this method in salt intake assessment and target organ damage. 1. We enrolled 510 cases of hospitalized patients with hypertension, 2/3 of them were arranged randomly to formula group to develop a new formula and the remainings were used to test the performance of the formula. All participants were instructed to collect a 24-h urine sample, a second morning voiding urine sample (SMU), and a post-meridiem urine sample in the late afternoon or early evening, prior to the evening meal (PMU). All samples were sent to measure sodium and creatinine concentration.2. We compared the differences of office blood pressure, 24-hour ambulatory blood pressure and left ventricular hypertrophy, vascular stiffness and urine protein among groups of different sodium intake. 24hour sodium excretion formulas was obtained using SMU and PMU respectively, which have good cosistency. The difference between the estimated and measured values in sodium excretion is 12.66mmol/day (SMU) and 9.41mmol/day (PM), to be equal to 0.7 g (SMU) and 0.6 g (PM) salt intake. Comparing with Kawasaki and Tanaka method, the new formula shows the lower degree of deviation, and higher accuracy and precision. Blood pressure of high urinary sodium group is higher than that in low urinary sodium group (P < 0.05). Left ventricular hypertrophy and urinary albumin/creatinine aggravated with the salt intake increase, this has eliminated the influence of other factors. All of morphologies of the relationship between ambulatory arterial stiffness index, pulse wave velocity and carotid intima-media thickness with quartiles of sodium intake resembled a J-shaped curve. In Chinese hypertensive population, the formulas to estimate 24-h urinary sodium using spot urinary samples spot urine are considered useful for estimating the mean level of population salt intake, and have a role in evaluating target organ damage.
Urpi-Sarda, Mireia; Boto-Ordóñez, María; Queipo-Ortuño, María Isabel; Tulipani, Sara; Corella, Dolores; Estruch, Ramon; Tinahones, Francisco J; Andres-Lacueva, Cristina
2015-09-01
The discovery of biomarkers of intake in nutritional epidemiological studies is essential in establishing an association between dietary intake (considering their bioavailability) and diet-related risk factors for diseases. The aim is to study urine and plasma phenolic and microbial profile by targeted metabolomics approach in a wine intervention clinical trial for discovering and evaluating food intake biomarkers. High-risk male volunteers (n = 36) were included in a randomized, crossover intervention clinical trial. After a washout period, subjects received red wine or gin, or dealcoholized red wine over four weeks. Fasting plasma and 24-h urine were collected at baseline and after each intervention period. A targeted metabolomic analysis of 70 host and microbial phenolic metabolites was performed using ultra performance liquid chromatography-tandem mass spectrometer (UPLC-MS/MS). Metabolites were subjected to stepwise logistic regression to establish prediction models and received operation curves were performed to evaluate biomarkers. Prediction models based mainly on gallic acid metabolites, obtained sensitivity, specificity and area under the curve (AUC) for the training and validation sets of between 91 and 98% for urine and between 74 and 91% for plasma. Resveratrol, ethylgallate and gallic acid metabolite groups in urine samples also resulted in being good predictors of wine intake (AUC>87%). However, lower values for metabolites were obtained in plasma samples. The highest correlations between fasting plasma and urine were obtained for the prediction model score (r = 0.6, P<0.001), followed by gallic acid metabolites (r = 0.5-0.6, P<0.001). This study provides new insights into the discovery of food biomarkers in different biological samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Susukida, Ryoko; Crum, Rosa M; Ebnesajjad, Cyrus; Stuart, Elizabeth A; Mojtabai, Ramin
2017-07-01
To compare randomized controlled trial (RCT) sample treatment effects with the population effects of substance use disorder (SUD) treatment. Statistical weighting was used to re-compute the effects from 10 RCTs such that the participants in the trials had characteristics that resembled those of patients in the target populations. Multi-site RCTs and usual SUD treatment settings in the United States. A total of 3592 patients in 10 RCTs and 1 602 226 patients from usual SUD treatment settings between 2001 and 2009. Three outcomes of SUD treatment were examined: retention, urine toxicology and abstinence. We weighted the RCT sample treatment effects using propensity scores representing the conditional probability of participating in RCTs. Weighting the samples changed the significance of estimated sample treatment effects. Most commonly, positive effects of trials became statistically non-significant after weighting (three trials for retention and urine toxicology and one trial for abstinence); also, non-significant effects became significantly positive (one trial for abstinence) and significantly negative effects became non-significant (two trials for abstinence). There was suggestive evidence of treatment effect heterogeneity in subgroups that are under- or over-represented in the trials, some of which were consistent with the differences in average treatment effects between weighted and unweighted results. The findings of randomized controlled trials (RCTs) for substance use disorder treatment do not appear to be directly generalizable to target populations when the RCT samples do not reflect adequately the target populations and there is treatment effect heterogeneity across patient subgroups. © 2017 Society for the Study of Addiction.
Mobile Technology Application for Improved Urine Concentration Measurement Pilot Study.
Walawender, Laura; Patterson, Jeremy; Strouse, Robert; Ketz, John; Saxena, Vijay; Alexy, Emily; Schwaderer, Andrew
2018-01-01
Objectives: Low hydration has a deleterious effect on many conditions. In the absence of a urine concentrating defect, urine concentration is a marker of hydration status. However, markers to evaluate hydration status have not been well studied in children. The objectives of this paper are to compare measures of thirst and urine concentration in children and to develop a novel mobile technology application to measure urine concentration. Study Design: Children age 12-17 years were selected ( n = 21) for this pilot study. Thirst perception, specific gravity (automated dipstick analysis and refractometer), and urine color scale results were correlated to urine osmolality. The technology department developed a mobile technology camera application to measure light penetrance into urine which was tested on 25 random anonymized urine samples. Results: The patients' thirst perception and color scale as well as two researchers color scale did not significantly correlate with osmolality. Correlation between osmolality and hydration markers resulted in the following Pearson coefficients: SG automated dipstick, 0.61 ( P 0.003); SG refractometer, 0.98 ( P < 0.0001); urine color scale (patient), 0.37 ( P 0.10), and light penetrance, -0.77 ( P < 0.0001). The correlation of light penetrance with osmolality was stronger than all measures except SG by refractometer and osmolality. Conclusion: The mobile technology application may be a more accurate tool for urine concentration measurement than specific gravity by automated dipstick, subjective thirst, and urine color scale, but lags behind specific gravity measured by refractometer. The mobile technology application is a step toward patient oriented hydration strategies.
Bocanegra, Cristina; Gallego, Sara; Mendioroz, Jacobo; Moreno, Milagros; Sulleiro, Elena; Salvador, Fernando; Sikaleta, Nicolau; Nindia, Arlette; Tchipita, Daniel; Joromba, Morais; Kavaya, Sebastiao; Sánchez Montalvá, Adrián; López, Teresa; Molina, Israel
2015-01-01
Introduction Schistosomiasis remains a public health major problem and little is known in many areas, mainly in Sub-Saharan Africa Objectives To assess the burden and risk factors of schistosomiasis and intestinal parasitic helminthes in the children of Cubal, Angola, and to compare different diagnostic approaches for urinary schistosomiasis under field conditions. Methods A cross-sectional study was conducted. Urine and faeces samples of school children were microscopically studied. A random sample of children was obtained from an alphabetically arranged list of children, taking one of two children. Urine dipstick, colorimetric test and macrohaematuria were considered as indirect diagnostic methods and compared to direct urine examination. Possible risk factors for the infection were sex, age, distance to the river and previous treatment with praziquantel; the assessment was performed using Chi-square test. Results A total of 785 (61.18%) children showed S. haematobium eggs in urine; children living within 500 meters from the river had a higher odds for infection: Odds ratio 1.97 (1.45–2.7 CI 95%); urine dipstick showed sensitivity of 96% and specificity of 61.3%, with a positive predictive value; colorimetric test showed sensitivity of 52.5%, specificity of 74.6% and a positive predictive value of 77%. Proteinuria was present in 653 (51.1%) children, being more frequent in children with S. haematobium in urine (75.2%); 32 of 191 stool samples (16%) showed the presence of other intestinal parasites and 8 (4%) for S. haematobium. Conclusions Prevalence of urinary schistosomiasis in our study area is much higher than the national average, considering it as a high-risk community. Proximity to a source of water was a risk factor for the infection. Indirect tests, as urine dipstick and colorimetric test, were useful tools for diagnosis, due to ease of use and low cost. Proteinuria was a common finding, probably showing an early structural damage due to schistosomiasis in this group of children. PMID:26474169
Detection of Cytomegalovirus (CMV) Infection in Wheezing Infants by Urine DNA and Serum IgG Testing.
Zeng, Zhao-Cheng; Chang, Qing; Sun, Zhi-Wei; Song, Ming-Mei; Jin, Xin-Ling; Jiang, Shu-Ya; Yang, Xia
2017-03-11
BACKGROUND The aim of this study was to investigate the involvement of CMV infection in wheezing infants and the association between CMV-DNA and immunoglobulins (Igs). MATERIAL AND METHODS A total of 243 wheezing infants and 3,000 parturients were enrolled in this study. The infants were randomly grouped to receive blood HCMV-DNA tests (n=46) or urine HCMV-DNA tests (n=197). Furthermore, all participants had serum CMV-specific IgM and IgG testing. Afterwards, 10 HCMV-IgG positive infants were randomly selected for simultaneous blood and urine HCMV-DNA tests, and 25 HCMV-IgG positive puerperants were randomly selected for urine HCMV-DNA tests. RESULTS The detection rate of urine HCMV-DNA was significantly higher than that of blood HCMV-DNA (67.5% vs. 13.0%, p<0.001). Fifteen (6.2%) and 190 (80.0%) infants showed positive CMV-specific IgM and IgG results (p<0.001), respectively. Among the 10 HCMV-IgG positive infants tested further, only two infants had positive HCMV-DNA blood tests, while all of the 10 infants had positive HCMV-DNA urine tests. However, HCMV-DNA was not detected in the urine of the 25 randomly selected parturients positive for HCMV-IgG. CONCLUSIONS CMV infection may be one of the causes of wheezing in infants; CMV infection can be detected by urine-HCMV-DNA and serum HCMV-IgG testing. Infants were more susceptible to CMV infection than parturients.
Silverman, Kenneth; Svikis, Dace; Wong, Conrad J; Hampton, Jacqueline; Stitzer, Maxine L; Bigelow, George E
2002-08-01
Long-term Therapeutic Workplace effects were evaluated in heroin- and cocaine-dependent, unemployed, treatment-resistant young mothers. Participants were paid to work or to train in the Therapeutic Workplace but had to provide drug-free urine samples to gain daily access. Participants (N = 40) were randomly assigned to a Therapeutic Workplace or usual care control group. Therapeutic Workplace participants could work for 3 years. Relative to controls, Therapeutic Workplace participants increased cocaine (28% vs. 54% negative; p = .04) and opiate (37% vs. 60% negative; p = .05) abstinence on the basis of monthly urine samples collected until 3 years after intake. The Therapeutic Workplace can be an effective long-term treatment of cocaine and heroin addiction in poor and chronically unemployed young mothers.
Das, Moupali; Santos, Deirdre; Matheson, Tim; Santos, Glenn-Milo; Chu, Priscilla; Vittinghoff, Eric; Shoptaw, Steve; Colfax, Grant N.
2010-01-01
Objective To determine whether actively using, methamphetamine (meth)-dependent men who have sex with men (MSM) could be enrolled and retained in a pharmacologic intervention trial, and the degree to which participants would adhere to study procedures, including medication adherence. Study design Phase II randomized, double-blind trial of bupropion vs. placebo. Methods Thirty meth-dependent, sexually active MSM were randomized to receive daily bupropion XL 300 mg or placebo for 12 weeks. Participants received weekly substance use counseling, provided weekly urine specimens, and completed monthly audio-computer assisted self-interview (ACASI) behavioral risk assessments. Adherence was measured by medication event monitoring systems (MEMS) caps (the number of distinct MEMS cap openings divided by the number of expected doses) and self-report. Results Ninety percent completed the trial: 89% of monthly ACASIs were completed, 81% of study visits were attended, and 81% of urine samples were collected. Adherence by MEMS cap was 60% and by self-report was 81% and did not differ significantly by treatment assignment. The median number of positive urine samples was 5.5 out of a possible 11 (50%). Participants in both arms reported similar declines in the median number of sex partners (P = 0.52). No serious adverse events occurred and there were no significant differences in adverse events by treatment assignment (P = 0.11). Conclusions It is feasible to enroll and retain actively using, meth-dependent MSM in a pharmacologic intervention. Bupropion was well tolerated. Study participation and retention rates were high, however, study drug medication adherence was only moderate. Findings support a larger trial with improved adherence support to evaluate the efficacy of bupropion and other pharmacologic interventions for meth dependence in this population. PMID:20397286
Ahmed, Mubashir; Fatmi, Zafar; Ali, Arif
2014-01-01
Long-term exposure to arsenic has been associated with manifestation of skin lesions (melanosis/keratosis) and increased risk of internal cancers (lung/bladder). The objective of the study described here was to determine the relationship between exposure of arsenic through drinking groundwater and urinary arsenic excretion among adults > or =15 years of age living in Khairpur district, Pakistan. Total arsenic was determined in drinking groundwater and in spot urine samples of 465 randomly selected individuals through hydride generation-atomic absorption spectrometry. Spearman's rank correlation coefficient was calculated between arsenic in drinking groundwater and arsenic excreted in urine. The median arsenic concentration in drinking water was 2.1 microg/L (range: 0.1-350), and in urine was 28.5 microg/L (range: 0.1-848). Positive correlation was found between total arsenic in drinking water and in urine (r = .52, p < .01). Urinary arsenic may be used as a biomarker of arsenic exposure through drinking water.
Effects of Urin Cow Dosage on Growth and Production of Sorgum Plant (Sorghum Bicolor L) on Peat Land
NASA Astrophysics Data System (ADS)
Utami Lestari, Sri; Andrian, Andi
2017-12-01
Sweet sorghum (Sorghum bicolor (L)), is a potential cultivated plant, especially in marginal and dry areas, sorghum has an important role as a source of carbohydrates, sorghum is expected as an alternative choice for peatland cultivation, with the use of peatlands is also expected Raising awareness of the environment by cultivating more environmentally friendly plants. The aim of this research is to know the influence and get the best dosage of cow urine on growth and production of Sorghum (Sorghum bicolor L) plant on peat soil. The experiment was conducted experimentally by using Completely Randomized Design (RAL), with one factor, namely: Cow urine administration, given in 5 treatments and 4 replications, resulting in 20 trials. Each experimental unit consists of 4 plants and 2 plants to be sampled. The factors studied were A0 = dose of cow urine 0 cc / 1, A1 = dose of cow urine 25 cc / 1, A2 = dose of cow urine 50 cc / 1, A3 = dose of cow urine 75 cc / 1, A4 = dose Cow urine 100 cc / 1. Conclusion Giving of cow urine has significant effect on growth and production of sorghum plant which is seen on the parameters of plant height, leaf length, leaf width. While wet weight 100 seeds and dry weight of 100 seeds of sorghum plants have no significant effect. The best dose is given by A4 treatment with the best dose of 100 cc / 1.
Castaneto, Marisol S.; Scheidweiler, Karl B.; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L.; Martin, Thomas M.; Huestis, Marilyn A.
2014-01-01
Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20,017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1,432 presumptive positive specimens. We analyzed all presumptive positive and 1,069 negative specimens with our qualitative synthetic cannabinoid LC-MS/MS method, which confirmed 290 positive specimens. All 290 positive and 487 randomly-selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date. 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-018 N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1–2434), 5.1 (0.1–1239), 2.0 (0.1–321), 1.1 (0.1–48.6), and 1.1 (0.1–250) μg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although, hydroxyindoles also were observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. PMID:25231213
Changes in the Optical Properties of Simulated Shuttle Waste Water Deposits: Urine Darkening
NASA Technical Reports Server (NTRS)
Albyn, Keith; Edwards, David; Alred, John
2003-01-01
Manned spacecraft have historically dumped the crew generated waste water overboard, into the environment in which the spacecraft operates, sometimes depositing the waste water on the external spacecraft surfaces. The change in optical properties of wastewater deposited on spacecraft external surfaces, from exposure to space environmental effects, is not well understood. This study used nonvolatile residue (NVR) from Human Urine to simulate wastewater deposits and documents the changes in the optical properties of the NVR deposits after exposure to ultra violet(UV)radiation. Twenty four NVR samples of, 0-angstromes/sq cm to 1000-angstromes/sq cm, and one sample contaminated with 1 to 2-mg/sq cm were exposed to UV radiation over the course of approximately 6151 equivalent sun hours (ESH). Random changes in sample mass, NVR, solar absorbance, and infrared emission were observed during the study. Significant changes in the UV transmittance were observed for one sample contaminated at the mg/sq cm level.
Changes in the Optical Properties of Simulated Shuttle Waste Water Deposits- Urine Darkening
NASA Technical Reports Server (NTRS)
Albyn, Keith; Edwards, David; Alred, John
2004-01-01
Manned spacecraft have historically dumped the crew generated waste waster overboard, into the environment in which the spacecraft operates, sometimes depositing the waste water on the external spacecraft surfaces. The change in optical properties of wastewater deposited on spacecraft external surfaces, from exposure to space environmental effects, is not well understood. This study used nonvolatile residue (NVR) from Human Urine to simulate wastewater deposits and documents the changes in the optical properties of the NVR deposits after exposure to ultra violet (UV) radiation. Twenty NVR samples of, 0-angstromes/sq cm to 1000-angstromes/sq cm, and one sample contaminated with 1 to 2-mg/sq cm were exposed to UV radiation over the course of approximately 6151 equivalent sun hours (ESH). Random changes in sample mass, NVR, solar absorbance, and infrared emission were observed during the study. Significant changes in the UV transmittance were observed for one sample contaminated at the mg/sq cm level.
Nibhanipudi, Kumara V
2016-01-01
To determine the incidence of urinary tract infections (UTIs) in infants and children (4 months to 6 years of age) with febrile diarrhea, as outpatients. This was a prospective institutional review board-approved study. patients (between 4 months and 6 years of age) were enrolled in the study who presented to the pediatric emergency room with a complaint of fever (rectal temperature 101°F or more) and diarrhea (watery stools >3 in number). The patients were evaluated for state of hydration, and also urine samples were collected. For those children not toilet trained, urine specimens were collected by bladder catheterization, and for those children toilet trained, urine specimens were obtained by midstream collection method. The urine samples obtained were sent for analysis and culture. Eighty patients were enrolled in the study. The number of specimens obtained by clean catch midstream was 20, and by bladder catheterization was 60. None of the urine specimens obtained by both methods of collection grew any organism. There was no increased incidence of infections in male children whether circumcised (10/60) or uncircumcised (50/60). The mean temperature was 102.8°F (range = 101°F to 105°F). Using in silico online 2 × 2 χ(2) test by comparing both the positive and negative urine culture results, 2-tailed P value is <.0001. Our prospective randomized study concluded that there is no increased incidence of UTIs in infants and children (4 months to 6 years of age) with febrile diarrhea.
Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing
Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre
2016-01-01
The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899
Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.
Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre
2016-05-17
The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.
Association between travel length and drug use among Brazilian truck drivers.
Sinagawa, Daniele Mayumi; De Carvalho, Heráclito Barbosa; Andreuccetti, Gabriel; Do Prado, Natanael Vitoriano; De Oliveira, Keziah Cristina Barbosa Gruber; Yonamine, Mauricio; Muñoz, Daniel Romero; Gjerde, Hallvard; Leyton, Vilma
2015-01-01
To investigate whether the use of the stimulants amphetamines and cocaine by truck drivers in Brazil was related to travel length. Truck drivers were randomly stopped by the Federal Highway Police on interstate roads in Sao Paulo State during morning hours from 2008 to 2011 and invited to participate in the project "Comandos de Saúde nas Rodovias" (Health Commands on the Roads). Participants were asked about the use of drugs, travel distance, and age, and gender was recorded. Samples of urine were collected and analyzed for amphetamine, benzoylecgonine (a metabolite of cocaine), and carboxytetrahydrocannabinol (THC-COOH; a metabolite of cannabis) by immunological screening and quantification by gas chromatography-mass spectroscopy. Current use of amphetamine, cocaine, and cannabis was reported by 5.7%, 0.7%, and 0.3% of the truck drivers, respectively. Amphetamine, benzoylecgonine, and THC-COOH were found in urine samples from 5.4%, 2.6,% and in 1.0% of the drivers, respectively. There was a significant association between the positive cases for amphetamine and reported travel length; 9.9% of urine samples from drivers who reported travel length of more than 270 km were positive for amphetamine, and 10.9% of those drivers reported current use of amphetamines. In most cases, appetite suppressants containing amphetamines had been used, but the purpose was most often to stay awake and alert while driving. Truck drivers with travel length of more than 270 km had significantly higher odds ratio (OR) for having a urine sample that was positive for amphetamine when adjusted for age as confounding factor (OR = 9.41, 95% confidence interval [CI], 3.97-22.26). No significant association was found between the use of cocaine or cannabis and travel length. Truck drivers who reported driving more than 270 km had significantly higher frequencies of urine samples positive for amphetamine and reported significantly more frequent current use of amphetamines than those who reported shorter driving distances.
Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina
2013-10-10
Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.
Rocha, Bruno Alves; da Costa, Bruno Ruiz Brandão; de Albuquerque, Nayara Cristina Perez; de Oliveira, Anderson Rodrigo Moraes; Souza, Juliana Maria Oliveira; Al-Tameemi, Maha; Campiglia, Andres Dobal; Barbosa, Fernando
2016-07-01
In this study, a novel method combining dispersive liquid-liquid microextraction (DLLME) and fast liquid chromatography coupled to mass spectrometry (LC-MS/MS) was developed and validated for the extraction and determination of bisphenol A (BPA) and six bisphenol analogues, namely bisphenol S (BPS), bisphenol F (BPF), bisphenol P (BPP), bisphenol Z (BPZ), bisphenol AP (BPAP) and bisphenol AF (BPAF) in human urine samples. Type and volume of extraction and disperser solvents, pH sample, ionic strength, and agitation were evaluated. The matrix-matched calibration curves of all analytes were linear with correlation coefficients higher than 0.99 in the range level of 0.5-20.0ngmL(-1). The relative standard deviation (RSD), precision, at three concentrations (1.0, 8.0 and 15.0ngmL(-1)) was lower than 15% with accuracy ranging from 90 to 112%. The biomonitoring capability of the new method was confirmed with the analysis of 50 human urine samples randomly collected from Brazilians. BPA was detected in 92% of the analyzed samples at concentrations ranging
NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, S; Brian Culligan, B
2007-08-28
The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less
Holtyn, August F; Koffarnus, Mikhail N; DeFulio, Anthony; Sigurdsson, Sigurdur O; Strain, Eric C; Schwartz, Robert P; Leoutsakos, Jeannie-Marie S; Silverman, Kenneth
2014-11-01
Determine if employment-based reinforcement can increase methadone treatment engagement and drug abstinence in out-of-treatment injection drug users. This study was conducted from 2008 to 2012 in a therapeutic workplace in Baltimore, MD. After a 4-week induction, participants (N=98) could work and earn pay for 26 weeks and were randomly assigned to Work Reinforcement, Methadone & Work Reinforcement, and Abstinence, Methadone & Work Reinforcement conditions. Work Reinforcement participants had to work to earn pay. Methadone & Work Reinforcement and Abstinence, Methadone, & Work Reinforcement participants had to enroll in methadone treatment to work and maximize pay. Abstinence, Methadone, & Work Reinforcement participants had to provide opiate- and cocaine-negative urine samples to maximize pay. Most participants (92%) enrolled in methadone treatment during induction. Drug abstinence increased as a graded function of the addition of the methadone and abstinence contingencies. Abstinence, Methadone & Work Reinforcement participants provided significantly more urine samples negative for opiates (75% versus 54%) and cocaine (57% versus 32%) than Work Reinforcement participants. Methadone & Work Reinforcement participants provided significantly more cocaine-negative samples than Work Reinforcement participants (55% versus 32%). The therapeutic workplace can promote drug abstinence in out-of-treatment injection drug users. Clinical trial registration number: NCT01416584. Copyright © 2014 Elsevier Inc. All rights reserved.
Holtyn, August F.; Koffarnus, Mikhail N.; DeFulio, Anthony; Sigurdsson, Sigurdur O.; Strain, Eric C.; Schwartz, Robert P.; Leoutsakos, Jeannie-Marie S.; Silverman, Kenneth
2014-01-01
Objective Determine if employment-based reinforcement can increase methadone treatment engagement and drug abstinence in out-of-treatment injection drug users. Method This study was conducted from 2008–2012 in a therapeutic workplace in Baltimore, MD. After a 4-week induction, participants (N=98) could work and earn pay for 26 weeks and were randomly assigned to Work Reinforcement, Methadone & Work Reinforcement, and Abstinence, Methadone & Work Reinforcement conditions. Work Reinforcement participants had to work to earn pay. Methadone & Work Reinforcement, and Abstinence, Methadone, & Work Reinforcement participants had to enroll in methadone treatment to work and maximize pay. Abstinence, Methadone, & Work Reinforcement participants had to provide opiate- and cocaine-negative urine samples to maximize pay. Results Most participants (92%) enrolled in methadone treatment during induction. Drug abstinence increased as a graded function of the addition of the methadone and abstinence contingencies. Abstinence, Methadone & Work Reinforcement participants provided significantly more urine samples negative for opiates (75% versus 54%) and cocaine (57% versus 32%) than Work Reinforcement participants. Methadone & Work Reinforcement participants provided significantly more cocaine-negative samples than Work Reinforcement participants (55% versus 32%). Conclusion The therapeutic workplace can promote drug abstinence in out-of-treatment injection drug users. PMID:24607365
Zacarias, Francielle Gibson da Silva; Vasconcellos, Silvio Arruda; Anzai, Eleine Kuroki; Giraldi, Nilson; de Freitas, Julio Cesar; Hartskeerl, Rudy
2008-01-01
In 2001, 698 urine samples were randomly collected from cattle at a slaughterhouse in the State of Paraná, Brazil. Direct examination using dark field microscopy was carried out immediately after collection. Five putative positive samples were cultured in modified EMJH medium, yielding two positive cultures (LO-14 and LO-10). Typing with monoclonal antibodies revealed that the two isolates were similar to Canicola (LO-14) and Copenhageni (LO-10). Microscopic agglutination test results show that Hardjo is the most common serovar in cattle in Brazil. Rats and dogs are the common maintenance hosts of serovars Copenhageni and Canicola. The excretion of highly pathogenic serovars such as Copenhageni and Canicola by cattle can represent an increasing risk for severe leptospirosis is large populations, mainly living in rural areas. PMID:24031301
Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration
Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang
2015-01-01
Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117
Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.
Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang
2015-01-01
The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.
The Total Urine Protein-to-Creatinine Ratio Can Predict the Presence of Microalbuminuria
Yamamoto, Kyoko; Yamamoto, Hiroyuki; Yoshida, Katsumi; Niwa, Koichiro; Nishi, Yutaro; Mizuno, Atsushi; Kuwabara, Masanari; Asano, Taku; Sakoda, Kunihiro; Niinuma, Hiroyuki; Nakahara, Fumiko; Takeda, Kyoko; Shindoh, Chiyohiko; Komatsu, Yasuhiro
2014-01-01
Background The Kidney Disease: Improving Global Outcomes chronic kidney disease (CKD) guidelines recommend that CKD be classified based on the etiology, glomerular filtration rate (GFR) and degree of albuminuria. The present study aimed to establish a method that predicts the presence of microalbuminuria by measuring the total urine protein-to-creatinine ratio (TPCR) in patients with cardiovascular disease (CVD) risk factors. Methods and Results We obtained urine samples from 1,033 patients who visited the cardiovascular clinic at St. Luke's International Hospital from February 2012 to August 2012. We measured the TPCR and the urine albumin-to-creatinine ratio (ACR) from random spot urine samples. We performed correlation, receiver operating characteristic (ROC) curve, sensitivity, and subgroup analyses. There was a strong positive correlation between the TPCR and ACR (R2 = 0.861, p<0.001). A ROC curve analysis for the TPCR revealed a sensitivity of 94.4%, a specificity of 86.1%, and an area under the curve of 0.903 for detecting microalbuminuria for a TPCR cut-off value of 84 mg/g of creatinine. The subgroup analysis indicated that the cut-off value could be used for patients with CVD risk factors. Conclusions These results suggest that the TPCR with an appropriate cut-off value could be used to screen for the presence of microalbuminuria in patients with CVD risk factors. This simple, inexpensive measurement has broader applications, leading to earlier intervention and public benefit. PMID:24614247
Diagnostic accuracy of the urinalysis for urinary tract infection in infants <3 months of age.
Schroeder, Alan R; Chang, Pearl W; Shen, Mark W; Biondi, Eric A; Greenhow, Tara L
2015-06-01
The 2011 American Academy of Pediatrics urinary tract infection (UTI) guideline suggests incorporation of a positive urinalysis (UA) into the definition of UTI. However, concerns linger over UA sensitivity in young infants. Infants with the same pathogenic organism in the blood and urine (bacteremic UTI) have true infections and represent a desirable population for examination of UA sensitivity. We collected UA results on a cross-sectional sample of 276 infants <3 months of age with bacteremic UTI from 11 hospital systems. Sensitivity was calculated on infants who had at least a partial UA performed and had ≥50 000 colony-forming units per milliliter from the urine culture. Specificity was determined by using a random sample of infants from the central study site with negative urine cultures. The final sample included 245 infants with bacteremic UTI and 115 infants with negative urine cultures. The sensitivity of leukocyte esterase was 97.6% (95% confidence interval [CI] 94.5%-99.2%) and of pyuria (>3 white blood cells/high-power field) was 96% (95% CI 92.5%-98.1%). Only 1 infant with bacteremic UTI (Group B Streptococcus) and a complete UA had an entirely negative UA. In infants with negative urine cultures, leukocyte esterase specificity was 93.9% (95% CI 87.9 - 97.5) and of pyuria was 91.3% (84.6%-95.6%). In young infants with bacteremic UTI, UA sensitivity is higher than previous reports in infants with UTI in general. This finding can be explained by spectrum bias or by inclusion of faulty gold standards (contaminants or asymptomatic bacteriuria) in previous studies. Copyright © 2015 by the American Academy of Pediatrics.
CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)
This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...
Tan, Chunjiang; Xiao, Lu; Chen, Wenlie
2015-01-01
Ginseng preparations contain high concentrations of germanium (Ge), which was reported to contribute to diuretic resistance or renal failure. However, Ge content in ginseng and the influence on renal functions remain unclear. Forty rats were randomly divided into control group, low, moderate, and high Ge ginseng-treated group and observed for 25 days. Daily urine, renal functions, and serum and urine electrolytics were measured. Ge retention in the organs and renal histological changes were also evaluated. Ge content ranged from 0.007 to 0.450 µg/g in various ginseng samples. Four groups showed no difference in the daily urine output, glomerular filtration rate, urinary electrolytes excretions, 24 h-urine protein, as well as plasma and urine urea nitrogen, creatinine, osmotic pressure, and pH values. Ge did not cause any renal pathological effects in this study. No Na and water retention was detected in the ginseng-treated groups. Ge retention in various organs was found highest in spleen, followed by the kidney, liver, lung, stomach, heart, and pancreas. The total Ge contents in various ginsengs were low, and ginseng treatment did not affect renal functions or cause renal histological changes. PMID:25711879
Hsieh, Cheng-Hsing; Yang, Stephen Shei-Dei; Chang, Shang-Jen
2016-06-01
To evaluate the efficacy of prophylactic antibiotics in reduction of infections after shock wave lithotripsy (SWL) in patients undergoing shock wave lithotripsy (SWL). The study was a randomized control trial. Between 2012 and 2014, patients with pre-operative sterile urine undergoing SWL were randomly assigned by the randomization ratio of 1:1 to receive prophylactic antibiotics with single-dose oral levofloxacin (500 mg) or no treatment (control group), respectively. Urinalysis and urine cultures were obtained between post-operative day five and seven, respectively. Pyuria was defined as ≥10 white blood cells per high power field (WBC/hpf). Significant bacteriuria was defined as ≥10(5) colony forming units per milliliter (CFU/mL) uropathogens. Febrile urinary tract infection (fUTI) was defined as body temperature higher than 38.0°C with pyuria or significant bacteriuria within seven days after SWL treatment. Initially, 274 patents underwent randomization with 135 and 139 patients in the levofloxacin and control group, respectively. A total of 206 patients (106 with placebo and 100 with levofloxacin) with complete follow-up of urinalysis were eligible for analysis. The rates of post-operative pyuria were not significantly different in patients with and without prophylaxis (8% versus 4.7%, p = 0.33). Moreover, there was also no significant difference in rates of bacteriuria in patients with and without prophylaxis (1% versus 0%, p = 0.49). Patients without follow-up urinalysis and urine culture received telephone survey. Among them, there was only one patient reporting post-SWL fever in the levofloxacin group (0.7%) compared with none (0%) in the control group (p = 0.49). As the results of the interim analysis revealed no benefit of levofloxacin in preventing post-SWL pyuria, bacteriuria, and fUTI, we terminated the study early before the pre-planned sample size was achieved. The incidence of asymptomatic and fUTI is low in patients with pre-SWL sterile urine undergoing SWL. Therefore, prophylactic antibiotics may be unnecessary in this cohort of patients.
Marsot, Amélie; Audebert, Christine; Attolini, Laurence; Lacarelle, Bruno; Micallef, Joelle; Blin, Olivier
A randomized cross-over, double blind placebo controlled study of smoked cannabis was carried out on occasional cannabis smokers. The objective of this research was to describe the pharmacokinetic parameters of THC and its metabolites in plasma, oral fluid and urine, from samples obtained simultaneously to provide estimations of THC and metabolites concentrations after smoking a cannabis cigarette. Blood, oral fluid and urine samples were collected until up to 72 h after smoking the cannabis cigarette (4% of delta-9-tetrathydrocannabinol (THC)). THC, 11-OH-THC and THC-COOH were analyzed by gas-chromatography-mass spectrometry. Pharmacokinetic parameters were estimated from these data. Eighteen male healthy adults participated in the study. In total, 560 plasma, 288 oral fluid and 448 urine samples were quantified for cannabinoids. Plasma, oral fluid and urine pharmacokinetic parameters were calculated. A wide range of median THC Cmax (1.6-160.0 µg/L and 55.4-123120.0 µg/L in plasma and oral fluid, respectively), 11-OH-THC Cmax (0-11.1 µg/L in plasma) and THC-COOH Cmax (1.0-56.3 µg/L in plasma) was observed. When expressed as a percentage of the total available THC dose, and corrected for molar equivalents, mean percentage of total THC dose excreted was 1.9 +/-2.5 % with range of 0.2-7.5%. This high inter-individual variability was also observed on other calculated pharmacokinetic parameters. Prediction of plasma THC concentration from THC oral fluid concentration or from THC-COOH urinary concentrations is not feasible due to the large variations observed. The results from this study support the assumption that a positive oral fluid THC result or a positive urine fluid result are indicative of a recent cannabis exposure. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.
Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef
2017-10-01
The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37.0% vs 28.2%, p = 0.227) (Figure). Children diagnosed with their UTI by use of bag urine in our experience carried the same risk of showing a VUR in a subsequent VCUG compared to those, where the initial diagnosis relied - beneath clinical criteria - on urine samples acquired by suprapubic puncture or catheterization. Consequently urine-sampling technique during initial UTI diagnosis alone should not be used as predictor for the reliability of UTI diagnosis and should not influence the further management after UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Spend today, clean tomorrow: Predicting methamphetamine abstinence in a randomized controlled trial
Murtaugh, Kimberly Ling; Krishnamurti, Tamar; Davis, Alexander L.; Reback, Cathy J.; Shoptaw, Steven
2013-01-01
Objective This secondary analysis of data from a randomized controlled trial tested two behavioral economics mechanisms (substitutability and delay discounting) to explain outcomes using contingency management (CM) for methamphetamine dependence. Frequency and purchase type (hedonic/utilitarian and consumable/durable) of CM payments were also examined. Methods 82 methamphetamine-dependent gay/bisexual men randomly assigned to conditions delivering CM received monetary vouchers in exchange for stimulant-negative urine samples in a 16-week trial requiring thrice weekly visits (Shoptaw et al., 2005). At any visit participants could redeem vouchers for goods. A time-lagged counting process Cox Proportional Hazards model for recurrent event survival analysis examined aspects of the frequency and type of these CM purchases. Results After controlling for severity of baseline methamphetamine use and accumulated CM wealth, as measured by cumulative successful earning days, participants who redeemed CM earnings at any visit (“spenders”) were significantly more likely to produce stimulant-negative urine samples in the subsequent visit, compared to those who did not redeem (“savers”) 1.011* [1.005, 1.017], Z=3.43, p<0.001. Conclusions Findings support the economic concept of substitutability of CM purchases and explain trial outcomes as a function of frequency of CM purchases rather than frequency or accumulated total CM earnings. Promotion of frequent purchases in incentive-based programs should facilitate substitution for the perceived value of methamphetamine and improve abstinence outcomes. PMID:24001246
Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2018-01-01
Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162
Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.
Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta
2017-01-01
Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?
Code of Federal Regulations, 2011 CFR
2011-10-01
... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...
49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?
Code of Federal Regulations, 2013 CFR
2013-10-01
... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...
49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?
Code of Federal Regulations, 2010 CFR
2010-10-01
... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...
49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?
Code of Federal Regulations, 2012 CFR
2012-10-01
... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...
49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?
Code of Federal Regulations, 2014 CFR
2014-10-01
... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...
Su, Meifang; Wang, Congyun; Li, Songtao; Ying, Xuhua; Zhao, Qi; Fu, Chaowei; Jiang, Qingwu
2016-01-01
To investigate the iodine status and its change among school-aged children in their morning urine and eating salt from 2012 to 2014 in Yuhuan County, Zhejiang Province, China. Three repeated cross-sectional studies were carried out at a same primary school in 2012, 2013 and 2014, respectively. Three classes were randomly selected from each of 3 to 5 grade by the cluster-stratified sampling every year. Totally, 1343 out of 1350 eligible children aged 8 to 10 years old were involved into this study. Their morning urine and salt eating at home were collected and tested. The overall median of urine iodine was 116.0 μg/L, and no significant change was found over year. The overall proportions of subjects with urine iodine < 50 μg/L, < 100 μg/L, and ≥ 300 μg/L were 4.8%, 38.6% and 3.5%, respectively, and there were little differences over year, gender and grade of children. An overall median of iodine from 1343 salt samples was 0.0 mg/kg and no year difference was statistically observed. The proportions of subjects consumed iodized salt significantly decreased from 25.1% in 2012 to 21.8% in 2013 and to 14.2% in 2014. There was a significant difference in urine iodine between subjects taken iodized salt or not and also a weak positive correlation between salt iodine and urine iodine. The nutritional status of iodine is overall stable, proper and safety in recent 3 years among school children in Yuhuan County. The coverage rate of iodized salt is very low.
A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...
Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.
Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S
2013-01-01
To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.
Castaneto, Marisol S; Scheidweiler, Karl B; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L; Martin, Thomas M; Huestis, Marilyn A
2015-06-01
Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20 017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1432 presumptive positive specimens. We analyzed all presumptive positive and 1069 negative specimens with our qualitative synthetic cannabinoid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, which confirmed 290 positive specimens. All 290 positive and 487 randomly selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date; 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1-2,434), 5.1 (0.1-1,239), 2.0 (0.1-321), 1.1 (0.1-48.6), and 1.1 (0.1-250) µg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although hydroxyindoles were also observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. This article is a U.S. Government work and is in the public domain in the USA.
Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter
2015-05-14
Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.
Stability of cannabinoids in urine in three storage temperatures.
Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C
1998-01-01
Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.
Substitution of human for horse urine disproves an accusation of doping*.
Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo
2008-09-01
In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.
Denipitiya, D T H; Chandrasekharan, N V; Abeyewickreme, W; Hartskeerl, R A; Hapugoda, M D
2017-03-23
Leptospirosis is an important emerging infectious disease in Sri Lanka. Rats are the most important reservoir of Leptospira but domestic and wild mammals may also act as important maintenance or accidental hosts. In Sri Lanka, knowledge of reservoir animals of leptospires is poor. The objective of this study was to identify potential reservoir animals of Leptospira in the District of Gampaha, Sri Lanka. Blood and kidney samples were collected from 38 rodents and mid-stream urine samples were randomly collected from 45 cattle and five buffaloes in the District of Gampaha. Kidney and urine samples were tested by real-time polymerase chain reaction (PCR) and serum samples were tested by the microscopic agglutination test (MAT). Of the 38 rodent kidney samples, 11% (4/38) were positive by real-time PCR. The prevalence of leptospiral carriage was 11% (3/26) and 8% (1/12) in female and male rodents, respectively. Three rodent serum samples were positive by MAT. Of the 50 cattle/buffalo urine samples tested, 10% (5/50) were positive by real-time PCR. The prevalence of leptospiral carriage was 9% (4/45) and 20% (1/5) in cattle and buffaloes, respectively. Results of PCR and MAT showed that Leptospira were present in a significant proportion of the rodents and farm animals tested in this study and suggest that these (semi-) domestic animals form an infection reservoir for Leptospira. Therefore, there is a potential zoonotic risk to public health, most notably to farmers in this area.
Downing, Harriet; Thomas-Jones, Emma; Gal, Micaela; Waldron, Cherry-Ann; Sterne, Jonathan; Hollingworth, William; Hood, Kerenza; Delaney, Brendan; Little, Paul; Howe, Robin; Wootton, Mandy; Macgowan, Alastair; Butler, Christopher C; Hay, Alastair D
2012-07-19
Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted.The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens.We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children.
2012-01-01
Background Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. Methods/design DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted. The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens. We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. Discussion This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children. PMID:22812651
Distribution and Depletion of Ractopamine in Goat Plasma, Urine and Various Muscle Tissues.
Zhao, Zhen; Gu, Xu; Su, Xiaoou; Li, Junguo; Li, Jun; Dong, Yingchao; Yang, Yujuan; Yao, Ting; Qin, Yuchang
2017-01-01
This study investigated the ractopamine (RAC) distribution and depletion process in goat plasma, urine and various muscle tissues which were associated with a potential risk for consumer health. The experiment was carried out in 21 goats (18 treated and 3 controls). Treated animals were administered orally a dose of 1 mg/kg body mass per day for 28 consecutive days and randomly sacrificed on Days 0.25, 1, 3, 7, 14 and 21 of the withdrawal period. RAC in goat samples was analyzed by using ultra-high performance liquid chromatography-quadrupole-orbitrap high-resolution mass spectrometry. RAC was below the limits of detection (LOD = 0.15 ng/mL) in plasma while which was higher than the LOD in urine on withdrawal day 21. The residues in goat longissimus dorsi muscle, biceps femoris muscle and triceps surae muscle were differed significantly. These findings demonstrated that urine can be used as the target matrix for monitoring RAC abuse in goat. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...
Estrogen levels in serum and urine of vegetarian and omnivore premenopausal women
Harmon, Brook; Morimoto, Yukiko; Beckford, Fanchon; Franke, Adrian A.; Stanczyk, Frank Z.; Maskarinec, Gertraud
2014-01-01
Objective Based on the hypothesis that high-meat diets may increase breast cancer risk through hormonal pathways, this analysis compared estrogens in serum and urine by meat-eating status. Design Intervention with repeated measures. Setting Two randomized soy trials (BEAN1 and BEAN2) among premenopausal healthy women. Subjects BEAN1 participants completed 7 unannounced 24-hour dietary recalls and donated 5 blood and urine samples over 2 years. BEAN2 women provided 7 recalls and 3 samples over 13 months. Serum samples were analyzed for estrone (E1) and estradiol (E2) using radioimmunoassays. Nine estrogen metabolites were measured in urine by liquid chromatography mass spectrometry. Semi-vegetarians included women who reported <30 g/day of red meat, poultry, and fish and pescatarians who consumed <20 g/day of meat/poultry but >10 g/day of fish. All other women were classified as non-vegetarians. We applied mixed models to compute least-square means by vegetarian status adjusted for potential confounders. Results The mean age of the 272 participants was 41.9±4.5 years. Serum E1 (85 vs 100 pg/mL, p=0.04) and E2 (140 vs 154 pg/mL, p=0.04) levels were lower in the 37 semi-vegetarians than in the 235 non-vegetarians. The sum of the 9 urinary estrogen metabolites (183 vs 200 pmol/mg creatinine, p=0.27) and the proportions of individual estrogens and pathways did not differ by meat-eating status. Restricting the models to the samples collected during the luteal phase strengthened the associations. Conclusions Given the limitations of this study, the lower levels of serum estrogens in semi-vegetarians than non-vegetarians need confirmation in larger populations. PMID:24050121
Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J
2016-07-01
Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.
Silverman, K; Svikis, D; Robles, E; Stitzer, M L; Bigelow, G E
2001-02-01
This study evaluated a novel drug abuse treatment, the Therapeutic Workplace. In this treatment, patients are paid to perform jobs or to participate in job training. Salary is linked to abstinence by requiring patients to provide drug-free urine samples to gain access to the workplace. Pregnant and postpartum drug abuse patients (N = 40) were randomly assigned to a Therapeutic Workplace or usual care control group. Therapeutic Workplace participants were invited to work 3 hr every weekday for 6 months and could earn up to $4,030 in vouchers for abstinence, workplace attendance, and performance. On average, 45% of participants attended the workplace per day. Relative to controls, the Therapeutic Workplace nearly doubled patients' abstinence from opiates and cocaine (33% vs. 59% of thrice-weekly urine samples drug negative, respectively, p < .05). The Therapeutic Workplace can effectively treat heroin and cocaine abuse in pregnant and postpartum women.
Yuste, Rosario Sanchez; Frías, Carolina; López, Ana; Vallejo, Carlos; Martín, Paloma; Bellas, Carmen
2008-01-01
To compare the diagnostic value of cytology and immunohistochemistry staining (IHS) of urine samples for polyomavirus reactivation diagnosis. Sixty-eight urine samples collected from 18 immunosuppressed patients were analyzed by Papanicolaou and IHS with a JC/BK virus-specific monoclonal antibody. Overall, polyomavirus BK (BKV) was positive in 11 of 18 patients (61.1%) (3 of whom developed hemorrhagic cystitis) and in 23 of 68 urine samples (28%). Of 23 samples, 4 (17%) were positive by 1 of the 2 techniques, only. Of 23 samples, 19 (83%) were positive by both methods. In matching urine samples from the same patient, the number of BKV-infected positive cells detected by IHS in urine slides was higher than those detected by Papanicolaou staining (71.3%). The main advantage of LHS is that it allowed confirmation of BKV infection diagnosis in urine samples. IHS detected more BKV-infected cells in samples with few positive urothelial cells, which would have gone undetected if only Papanicolaou staining had been used as the BKV screening method. Urine samples testing for BKV by both techniques will improve diagnosis in asymptomatic patients, allowing early therapeutic intervention and a better clinical outcome.
Zapf, Antonia; Gwinner, Wilfried; Karch, Annika; Metzger, Jochen; Haller, Hermann; Koch, Armin
2015-09-15
Reliable and timely detection of acute rejection in renal transplant patients is important to preserve the allograft function and to prevent premature allograft failure. The current gold standard for the rejection diagnosis is an allograft biopsy which is usually performed upon an unexplained decline in allograft function. Because of the invasiveness of the biopsy, non-invasive tests have been suggested to diagnose acute rejection including mass spectrometry analysis of urine samples. The aim of this study is to examine the diagnostic accuracy of mass spectrometry analysis in urine for the diagnosis of acute rejections using the biopsy as gold-standard. The study is an ongoing prospective, single-arm, multicentre, phase 3 diagnostic accuracy study. It started in October 2011 and will be concluded in December 2015. Patient within the first year after transplantation who are scheduled for a biopsy to clarify unexplained impairment of the allograft are consecutively recruited into the study. The overall sample size (n = 600) was calculated to demonstrate a sensitivity of 83 % and a specificity of 70 % for a one-sided type one error of 2.5 % and a power of 80 % per hypothesis. Biopsy evaluation and mass spectrometry analysis of urine samples (obtained immediately before biopsy) are performed independently by different readers without knowledge from the respective other assessment. The follow-up observation period is 6 months. For the primary analysis, the lower limits of the two-sided 95 % Wald confidence intervals for sensitivity and specificity will be compared with the pre-specified thresholds (83 % for sensitivity and 70 % for specificity). In secondary analyses the predictive values, the diagnostic measures in subgroups, and the clinical course will be assessed. Previous phase 2 diagnostic accuracy studies (in small selected study populations) provided sufficient evidence to suggest mass spectrometry on urine samples as a promising approach to detect acute rejections. This study determines the diagnostic performance of the test in the routine setting of post-transplant patient care, compared to the biopsy-based rejection diagnosis. The next step would be a randomized trial to compare the two diagnostic strategies (including the urine test or not) in relation to patient relevant endpoints. NCT01315067 ; March 14, 2011.
Basic or extended urine sampling to analyse urine production?
Denys, Marie-Astrid; Kapila, Vansh; Weiss, Jeffrey; Goessaert, An-Sofie; Everaert, Karel
2017-09-01
Frequency volume charts are valuable tools to objectify urine production in patients with nocturia, enuresis or nocturnal incontinence. Analyses of daytime and nighttime urine (=basic collection) or analyses of urine samples collected every 3 h (=extended collection) extend this evaluation by describing circadian patterns of water and solute diuresis (=renal function profiles). To assess intra-individual correlation and agreement between renal function profiles provided using basic and extended urine collections, and using two extended urine collections. To create a short-form of the extended collection. This prospective observational study was executed at Ghent University Hospital, Belgium. Study participation was open for anyone visiting the hospital. Participants collected one basic and two extended 24-h urine collections. Urinary levels of osmolality, sodium and creatinine were determined. There was a moderate to strong correlation between results of basic and extended urinalyses. Comparing both extended urinalyses showed a moderate correlation between the eight individual samples and a weak to strong correlation between the mean daytime and nighttime values of renal functions. Different samples could be considered as most representative for mean daytime values, while all samples collected between 03 and 05am showed the highest agreement with mean nighttime values of renal function. Since there is a good correlation and agreement between basic and extended urine collections to study the mechanisms underlying urine production, the choice of urine sampling method to evaluate urine production depends on the purpose. A nighttime-only urine sample collected between 03 and 05am may be the most practical approach. © 2017 Wiley Periodicals, Inc.
Effects of diet composition on mutagenic activity in urine.
Ohara, Akihiro; Matsuhisa, Tsugio
2004-01-01
The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.
Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige
2016-08-01
Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Amro, Osama W; Paulus, Jessica K; Noubary, Farzad; Perrone, Ronald D
2016-12-01
Autosomal dominant polycystic kidney disease (ADPKD) affects millions of people worldwide. Vasopressin promotes disease progression. A randomized controlled trial with equal (1:1) allocation. This trial examined the effect of combining a low-osmolar (low-sodium [1,500mg/d], low-protein [0.8g per kilogram of body weight]) diet and adjusted water intake on vasopressin secretion in 34 patients with ADPKD. Participants were randomly assigned to receive a low-osmolar diet followed by adjusted water intake to achieve urine osmolality ≤ 280mOsm/kg water versus no intervention for 2 weeks. The primary outcome of the study was change (delta) in copeptin levels and urine osmolality between the intervention and control groups from baseline to 2 weeks. Fasting plasma copeptin level, 24-hour urine osmolality, and total solute intake. Baseline characteristics of the 2 groups were similar. Mean plasma copeptin levels and urine osmolality declined from 6.2±3.05 (SD) to 5.3±2.5pmol/L (P=0.02) and from 426±193 to 258±117mOsm/kg water (P=0.01), respectively, in the intervention group compared to a nonsignificant change in the control group (from 4.7±3.6 to 5.07±4pmol/L [P=0.2] and 329±159 to 349±139mOsm/kg water [P=0.3], respectively). The change in copeptin levels (primary outcome) and urine osmolality was statistically significant between the intervention and control groups (delta copeptin, -0.86±1.3 vs +0.39±1.2pmol/L [P=0.009]; delta urine osmolality, -167±264 vs +20±80mOsm/kg water [P=0.007], respectively). Total urinary solute decreased in only the intervention group and significantly differed between groups at week 1 (P=0.03), reducing mean water prescription from 3.2 to 2.6L/d. Small sample size and short follow-up. We developed a stepwise dietary intervention that led to a significant reduction in vasopressin secretion in patients with ADPKD. Furthermore, this intervention led to a reduction in water required for vasopressin reduction. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Urine Culture Testing in Community Nursing Homes: Gateway to Antibiotic Overprescribing.
Sloane, Philip D; Kistler, Christine E; Reed, David; Weber, David J; Ward, Kimberly; Zimmerman, Sheryl
2017-05-01
OBJECTIVE To describe current practice around urine testing and identify factors leading to overtreatment of asymptomatic bacteriuria in community nursing homes (NHs) DESIGN Observational study of a stratified random sample of NH patients who had urine cultures ordered in NHs within a 1-month study period SETTING 31 NHs in North Carolina PARTICIPANTS 254 NH residents who had a urine culture ordered within the 1-month study period METHODS We conducted an NH record audit of clinical and laboratory information during the 2 days before and 7 days after a urine culture was ordered. We compared these results with the urine antibiogram from the 31 NHs. RESULTS Empirical treatment was started in 30% of cases. When cultures were reported, previously untreated cases received antibiotics 89% of the time for colony counts of ≥100,000 CFU/mL and in 35% of cases with colony counts of 10,000-99,000 CFU/mL. Due to the high rate of prescribing when culture results returned, 74% of these patients ultimately received a full course of antibiotics. Treated and untreated patients did not significantly differ in temperature, frequency of urinary signs and symptoms, or presence of Loeb criteria for antibiotic initiation. Factors most commonly associated with urine culture ordering were acute mental status changes (32%); change in the urine color, odor, or sediment (17%); and dysuria (15%). CONCLUSIONS Urine cultures play a significant role in antibiotic overprescribing. Antibiotic stewardship efforts in NHs should include reduction in culture ordering for factors not associated with infection-related morbidity as well as more scrutiny of patient condition when results become available. Infect Control Hosp Epidemiol 2017;38:524-531.
Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.
Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil
2017-07-01
Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.
Huang, Liping; Crino, Michelle; Wu, Jason H Y; Woodward, Mark; Barzi, Federica; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Neal, Bruce
2016-02-01
Estimating equations based on spot urine samples have been identified as a possible alternative approach to 24-h urine collections for determining mean population salt intake. This review compares estimates of mean population salt intake based upon spot and 24-h urine samples. We systematically searched for all studies that reported estimates of daily salt intake based upon both spot and 24-h urine samples for the same population. The associations between the two were quantified and compared overall and in subsets of studies. A total of 538 records were identified, 108 were assessed as full text and 29 were included. The included studies involved 10,414 participants from 34 countries and made 71 comparisons available for the primary analysis. Overall average population salt intake estimated from 24-h urine samples was 9.3 g/day compared with 9.0 g/day estimated from the spot urine samples. Estimates based upon spot urine samples had excellent sensitivity (97%) and specificity (100%) at classifying mean population salt intake as above or below the World Health Organization maximum target of 5 g/day. Compared with the 24-h samples, estimates based upon spot urine overestimated intake at lower levels of consumption and underestimated intake at higher levels of consumption. Estimates of mean population salt intake based upon spot urine samples can provide countries with a good indication of mean population salt intake and whether action on salt consumption is required. Published by Oxford University Press on behalf of the International Epidemiological Association 2015. This work is written by US Government employees and is in the public domain in the US.
Neghab, Masoud; Jalilian, Hamed; Taheri, Shekoufeh; Tatar, Mohsen; Haji Zadeh, Zeynab
2018-06-01
This study was undertaken to ascertain whether light occupational exposure to pesticides by retailers might be associated with any liver, kidney, nervous system dysfunction or hematological abnormalities. In this cross-sectional study, 70 male pesticide retailers (cases) and 64 male subjects, randomly selected from the constructions workers of city council contractors, as the referent group, were investigated. Urine and blood samples were taken from all subjects for urine analysis, hematological and biochemical parameters. Data analysis was conducted through SPSS v.19 using t-test and chi-square test. The results of urine analysis showed that the frequency of abnormal urine tests was significantly higher in cases than in referent individuals. Similarly, the results of CBC showed that the mean values of monocyte, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin and platelet distribution width were significantly lower, and mean corpuscular hemoglobin concentration and red blood cell distribution width were significantly higher in retailers. No significant differences were found for other parameters. These findings indicate that an association exists between exposure to pesticides by retailers and early subtle and sub-clinical changes in the urine tests and hematological parameters. Engineering measures are recommended to eliminate exposure to pesticides and to prevent its associated outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.
Everly, Jeffrey J.; DeFulio, Anthony; Koffarnus, Mikhail N.; Leoutsakos, Jeannie-Marie S.; Donlin, Wendy D.; Aklin, Will M.; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Silverman, Kenneth
2011-01-01
Aims Naltrexone can be used to treat opioid dependence, but patients refuse to take it. Extended-release depot formulations may improve adherence, but long-term adherence rates to depot naltrexone are not known. This study determined long-term rates of adherence to depot naltrexone and whether employment-based reinforcement can improve adherence. Design Participants who were inducted onto oral naltrexone were randomly assigned to Contingency (n=18) or Prescription (n=17) groups. Participants were offered six depot naltrexone injections and invited to work at the therapeutic workplace weekdays for 26 weeks where they earned stipends for participating in job skills training. Contingency participants were required to accept naltrexone injections to maintain workplace access and to maintain maximum pay. Prescription participants could work independent of whether they accepted injections. Setting The therapeutic workplace, a model employment-based intervention for drug addiction and unemployment. Participants Opioid-dependent unemployed adults. Measurements Depot naltrexone injections accepted and opiate-negative urine samples. Findings Contingency participants accepted significantly more naltrexone injections than Prescription participants (81% versus 42%), and were more likely to accept all injections (66% versus 35%). At monthly assessments (with missing urine samples imputed as positive), the groups provided similar percentages of samples negative for opiates (74% versus 62%) and for cocaine (56% versus 54%). Opiate positive samples were more likely when samples were also positive for cocaine. Conclusions Employment-based reinforcement can maintain adherence to depot naltrexone. Future research should determine whether persistent cocaine use compromises naltrexone's effect on opiate use. Workplaces may be useful for promoting sustained adherence to depot naltrexone. PMID:21320227
Estimating mean change in population salt intake using spot urine samples.
Petersen, Kristina S; Wu, Jason H Y; Webster, Jacqui; Grimes, Carley; Woodward, Mark; Nowson, Caryl A; Neal, Bruce
2017-10-01
Spot urine samples are easier to collect than 24-h urine samples and have been used with estimating equations to derive the mean daily salt intake of a population. Whether equations using data from spot urine samples can also be used to estimate change in mean daily population salt intake over time is unknown. We compared estimates of change in mean daily population salt intake based upon 24-h urine collections with estimates derived using equations based on spot urine samples. Paired and unpaired 24-h urine samples and spot urine samples were collected from individuals in two Australian populations, in 2011 and 2014. Estimates of change in daily mean population salt intake between 2011 and 2014 were obtained directly from the 24-h urine samples and by applying established estimating equations (Kawasaki, Tanaka, Mage, Toft, INTERSALT) to the data from spot urine samples. Differences between 2011 and 2014 were calculated using mixed models. A total of 1000 participants provided a 24-h urine sample and a spot urine sample in 2011, and 1012 did so in 2014 (paired samples n = 870; unpaired samples n = 1142). The participants were community-dwelling individuals living in the State of Victoria or the town of Lithgow in the State of New South Wales, Australia, with a mean age of 55 years in 2011. The mean (95% confidence interval) difference in population salt intake between 2011 and 2014 determined from the 24-h urine samples was -0.48g/day (-0.74 to -0.21; P < 0.001). The corresponding result estimated from the spot urine samples was -0.24 g/day (-0.42 to -0.06; P = 0.01) using the Tanaka equation, -0.42 g/day (-0.70 to -0.13; p = 0.004) using the Kawasaki equation, -0.51 g/day (-1.00 to -0.01; P = 0.046) using the Mage equation, -0.26 g/day (-0.42 to -0.10; P = 0.001) using the Toft equation, -0.20 g/day (-0.32 to -0.09; P = 0.001) using the INTERSALT equation and -0.27 g/day (-0.39 to -0.15; P < 0.001) using the INTERSALT equation with potassium. There was no evidence that the changes detected by the 24-h collections and estimating equations were different (all P > 0.058). Separate analysis of the unpaired and paired data showed that detection of change by the estimating equations was observed only in the paired data. All the estimating equations based upon spot urine samples identified a similar change in daily salt intake to that detected by the 24-h urine samples. Methods based upon spot urine samples may provide an approach to measuring change in mean population salt intake, although further investigation in larger and more diverse population groups is required. © The Author 2016; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association
Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia
2005-01-01
A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.
Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M
2017-04-08
Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.
Gravitt, Patti E.; Dunn, S. Terence; Brown, David; Allen, Richard A.; Eby, Yolanda J.; Smith, Katie; Zuna, Rosemary E.; Zhang, Roy R.; Gold, Michael A.; Schiffman, Mark; Walker, Joan L.; Castle, Philip E.; Wentzensen, Nicolas
2014-01-01
While urine-based sampling for human papillomavirus (HPV) is being explored as a simple and noninvasive approach for cervical cancer screening, data comparing HPV genotyping in urine and those in cellular sampling of the cervix and vulva, and their correlation with rigorously confirmed cervical disease status, are sparse. We performed HPV genotyping on voided-urine and clinician-collected vulvar and cervical samples from 72 women undergoing colposcopy. Although urine-based HPV carcinogenic HPV detection was lower (58.3%) than cervical (73.6%) and vulvar (72.1%) detection (P = 0.05 and 0.07, respectively), the agreement of urine HPV with cervical and vulvar HPV was moderate (kappa = 0.55) and substantial (kappa = 0.62), respectively. Urine-based carcinogenic HPV detection had a clinical sensitivity of 80.8% (95% confidence interval [CI] = 60.7 to 93.5) and a specificity of 53.3% (95% CI = 37.9 to 68.3) for diagnosing cervical intraepithelial neoplasia grades 2/3 (CIN2/3) on histology; 90.0% of CIN3 was positive for urine HPV. The corresponding sensitivity and specificity values for vulvar sampling were 92% (95% CI = 74 to 99) and 40.5% (95% CI = 25.6 to 56.7), and those for cervical sampling were 96.2% (95% CI = 80.4 to 99.9) and 40% (95% CI = 25.7 to 55.7), respectively. HPV16 was the most common carcinogenic genotype detectable in 25% of urine, 33.8% of vulvar, and 31.9% of cervical samples overall, with prevalence increasing with cervical disease grade, regardless of the sampling method. Stronger cervical HPV PCR signal strengths were associated with increased frequency of urine HPV detection. In summary, the relatively lower detection rates but comparable clinical performance of urine-based HPV sampling underscore the need for larger studies to evaluate urine-based sampling for cervical cancer screening, epidemiologic studies, and postvaccination HPV disease surveillance. PMID:24197879
Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam
2017-05-01
Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.
Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P
2014-11-01
The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.
Bordelon, Hali; Ricks, Keersten M.; Pask, Megan E.; Russ, Patricia K.; Solinas, Francesca; Baglia, Mark L.; Short, Philip A.; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W.; Haselton, Frederick R.; Pettit, April C.
2017-01-01
Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1 milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5 mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found a increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. PMID:28285168
Bordelon, Hali; Ricks, Keersten M; Pask, Megan E; Russ, Patricia K; Solinas, Francesca; Baglia, Mark L; Short, Philip A; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W; Haselton, Frederick R; Pettit, April C
2017-05-01
Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found an increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. Copyright © 2017 Elsevier B.V. All rights reserved.
Dunn, Kelly; DeFulio, Anthony; Everly, Jeffrey J.; Donlin, Wendy D.; Aklin, Will M.; Nuzzo, Paul A.; Leoutsakos, Jeannie-Marie S.; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Silverman, Kenneth
2015-01-01
Oral naltrexone could be a promising relapse prevention pharmacotherapy for recently detoxified opioid-dependent patients, however interventions are often needed to promote adherence with this treatment approach. We recently conducted a study to evaluate a 26-week employment-based reinforcement intervention of oral naltrexone in unemployed injection drug users (Dunn et al., 2013). Participants were randomly assigned into a Contingency (n=35) group required to ingest naltrexone under staff observation to gain entry into a therapeutic workplace, or a Prescription (n=32) group given a take-home supply of oral naltrexone and access to the workplace without observed ingestion. Monthly urine samples were collected and analyzed for evidence for naltrexone adherence, opioid use, and cocaine use. As previously reported, Contingency participants provided significantly more naltrexone-positive urine samples than Prescription participants during the 26-week intervention period. The goal of this current study is to report the 12-month outcomes, which occurred 6 months after the intervention ended. Results at the 12-month visit showed no between-group differences in naltrexone-positive, opioid-negative, or cocaine-negative urine samples, and no participant self-reported using naltrexone at the follow-up visit. These results show that even after a period of successfully reinforced oral naltrexone adherence longer-term naltrexone use is unlikely to be maintained after reinforcement contingencies are discontinued. PMID:25134047
Burillo, Almudena; Rodríguez-Sánchez, Belén; Ramiro, Ana; Cercenado, Emilia; Rodríguez-Créixems, Marta; Bouza, Emilio
2014-01-01
Microbiological confirmation of a urinary tract infection (UTI) takes 24-48 h. In the meantime, patients are usually given empirical antibiotics, sometimes inappropriately. We assessed the feasibility of sequentially performing a Gram stain and MALDI-TOF MS mass spectrometry (MS) on urine samples to anticipate clinically useful information. In May-June 2012, we randomly selected 1000 urine samples from patients with suspected UTI. All were Gram stained and those yielding bacteria of a single morphotype were processed for MALDI-TOF MS. Our sequential algorithm was correlated with the standard semiquantitative urine culture result as follows: Match, the information provided was anticipative of culture result; Minor error, the information provided was partially anticipative of culture result; Major error, the information provided was incorrect, potentially leading to inappropriate changes in antimicrobial therapy. A positive culture was obtained in 242/1000 samples. The Gram stain revealed a single morphotype in 207 samples, which were subjected to MALDI-TOF MS. The diagnostic performance of the Gram stain was: sensitivity (Se) 81.3%, specificity (Sp) 93.2%, positive predictive value (PPV) 81.3%, negative predictive value (NPV) 93.2%, positive likelihood ratio (+LR) 11.91, negative likelihood ratio (-LR) 0.20 and accuracy 90.0% while that of MALDI-TOF MS was: Se 79.2%, Sp 73.5, +LR 2.99, -LR 0.28 and accuracy 78.3%. The use of both techniques provided information anticipative of the culture result in 82.7% of cases, information with minor errors in 13.4% and information with major errors in 3.9%. Results were available within 1 h. Our serial algorithm provided information that was consistent or showed minor errors for 96.1% of urine samples from patients with suspected UTI. The clinical impacts of this rapid UTI diagnosis strategy need to be assessed through indicators of adequacy of treatment such as a reduced time to appropriate empirical treatment or earlier withdrawal of unnecessary antibiotics.
Daley, Peter; Garcia, David; Inayatullah, Raheel; Penney, Carla; Boyd, Sarah
2018-05-28
DESIGNWe conducted a randomized, parallel, unblinded, superiority trial of a laboratory reporting intervention designed to reduce antibiotic treatment of asymptomatic bacteriuria (ASB).METHODSResults of positive urine cultures from 110 consecutive inpatients at 2 urban acute-care hospitals were randomized to standard report (control) or modified report (intervention). The standard report included bacterial count, bacterial identification, and antibiotic susceptibility information including drug dosage and cost. The modified report stated: "This POSITIVE urine culture may represent asymptomatic bacteriuria or urinary tract infection. If urinary tract infection is suspected clinically, please call the microbiology laboratory … for identification and susceptibility results." We used the following exclusion criteria: age <18 years, pregnancy, presence of an indwelling urinary catheter, samples from patients already on antibiotics, neutropenia, or admission to an intensive care unit. The primary efficacy outcome was the proportion of appropriate antibiotic therapy prescribed.RESULTSAccording to our intention-to-treat (ITT) analysis, the proportion of appropriate treatment (urinary tract infection treated plus ASB not treated) was higher in the modified arm than in the standard arm: 44 of 55 (80.0%) versus 29 of 55 (52.7%), respectively (absolute difference, -27.3%; RR, 0.42; P = .002; number needed to report for benefit, 3.7).CONCLUSIONSModified reporting resulted in a significant reduction in inappropriate antibiotic treatment without an increase in adverse events. Safety should be further assessed in a large effectiveness trial before implementationTRIAL REGISTRATION. clinicaltrials.gov#NCT02797613Infect Control Hosp Epidemiol 2018;1-6.
Urinary isoflavonoid excretion as a biomarker of dietary soy intake during two randomized soy trials
Morimoto, Yukiko; Beckford, Fanchon; Franke, Adrian A.; Maskarinec, Gertraud
2014-01-01
We evaluated urinary isoflavonoid excretion as a biomarker of dietary isoflavone intake during two randomized soy trials (13–24 months) among 256 premenopausal women with a total of 1,385 repeated urine samples. Participants consumed a high-soy diet (2 servings/day) and a low-soy diet (<3 servings/week), completed 7 unannounced 24-hour dietary recalls, and donated repeated urine samples, which were analyzed for isoflavonoid excretion by liquid chromatography methods. We computed correlation coefficients and applied logistic regression to estimate the area under the curve. Median daily dietary isoflavone intakes at baseline, during low- and high-soy diet were 0.5, 0.2, and 67.7 mg aglycone equivalents, respectively. The corresponding urinary isoflavonoid excretion values were 0.9, 1.1, and 43.9 nmol/mg creatinine. Across diets, urinary isoflavonoid excretion was significantly associated with dietary isoflavone intake (rs=0.51, AUC=0.85; p<0.0001) but not within diet periods (rs=0.05–0.06, AUC=0.565–0.573). Urinary isoflavonoid excretion is an excellent biomarker to discriminate between low- and high-soy diets across populations, but the association with dietary isoflavone intake is weak when the range of soy intake is small. PMID:24901088
Van Dorsten, Ferdi A; Daykin, Clare A; Mulder, Theo P J; Van Duynhoven, John P M
2006-09-06
The purpose of this study was to compare the effects of black and green tea consumption on human metabolism. Seventeen healthy male volunteers consumed black tea, green tea, or caffeine in a randomized crossover study. Twenty-four-hour urine and blood plasma samples were analyzed by NMR-based metabonomics, that is, high-resolution 1H NMR metabolic profiling combined with multivariate statistics. Green and black tea consumption resulted in similar increases in urinary excretion of hippuric acid and 1,3-dihydroxyphenyl-2-O-sulfate, both of which are end products of tea flavonoid degradation by colonic bacteria. Several unidentified aromatic metabolites were detected in urine specifically after green tea intake. Interestingly, green and black tea intake also had a different impact on endogenous metabolites in urine and plasma. Green tea intake caused a stronger increase in urinary excretion of several citric acid cycle intermediates, which suggests an effect of green tea flavanols on human oxidative energy metabolism and/or biosynthetic pathways.
Ford, Loretta T; Berg, Jonathan D
2016-11-01
Background Synthetic cannabinoids (NOIDS) are novel psychotropic drugs (NPS) currently freely sold in the United Kingdom as 'research chemicals'. Detection of NOIDS use is not available in current routine methods. Here we describe a marker which helps determine which patients have used these substances. Methods In a test case, ultra-performance liquid chromatography mass spectrometry (UPLC-Tof) was used to screen the legal high Herbal Haze II, the contents of hand-rolled cigarettes and five patient samples for NOIDS and their metabolites. Results Analysis of legal high Herbal Haze II and cigarettes identified the third generation adamantyl-type NOIDS N-(1-adamantyl)-1-pentyl-1H-indazole-3-carboxamide (AKB-48), 5F-AKB-48 and N-adamantyl-1-fluoropentylindole-3-carboxamide (STS-135). Out of 18 potential metabolites, 1-adamantylamine (C 10 H 17 N) was detected in all five urine samples. This adamantyl-type NOID marker was incorporated into our routine LC-MS/MS urine screen. Out of 14,436 random urine samples screened over eight months, 296 (2.05%) tested positive for the adamantyl-type NOID marker. Conclusion We have discovered a urine marker for identifying patients smoking legal high products containing the third generation adamantyl-type NOIDS such as AKB-48 and its fluoropentyl analogue 5F-AKB-48, which are among the most popular NOIDS currently available in legal high products sold in UK. This marker can be incorporated into routine LC-MS/MS drug screening alongside classic drugs of abuse. Positive detection rates for this new legal high marker are greater than for established classic drugs that are routinely screened such as amphetamine. This work highlights the need for a flexible toxicology screening service capable of adapting to changes in drug use such as the growing popularity of legal highs/NPS.
Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol
2013-11-15
Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.
Urine osmolality in the US population: Implications for environmental biomonitoring
Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana
2018-01-01
Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670
Confirmation of the Department of Transportation criteria for a substituted urine specimen.
Barbanel, Cheryl S; Winkelman, James W; Fischer, George A; King, Andrew J
2002-05-01
The purpose of this study was to determine whether people could naturally produce urine sufficiently dilute to meet the federal criteria for a "substituted" specimen. The United States Department of Transportation Regulations (49 Code of Federal Regulations Part 40) defines a urine specimen as substituted if it has a creatinine concentration of < or = 5 mg/dL and a specific gravity of < or = 1.001 or > or = 1.020. These criteria have been criticized based on the contention that an insufficient number of specimens had been tested from the same urine sample for both creatinine and specific gravity measurements. We reviewed the results of 803,130 random urine specimens measured for creatinine and/or specific gravity in a hospital-based laboratory. In this database, 13,467 urine specimens had both creatinine and specific gravity measurements. None of these 13,467 paired urine specimens met the lower limit of specific gravity (< or = 1.001) and creatinine (< or = 5 mg/dL) criteria for a Department of Transportation substituted specimen. We also examined the medical records of those patients meeting even one of the two criteria; creatinine concentration < or = 5 mg/dL or specific gravity < or = 1.001. These patients were neonatal, moribund, or so severely ill that essentially none could have been among the working population. These data in patients with various pathologic states support our belief that normal individuals do not produce urine dilute enough to meet the lower limit of the specific gravity (< or = 1.001) and creatinine (< or = 5 mg/dL) required for meeting substituted specimen criteria. Eleven patients met the criteria for a substituted specimen, with elevated specific gravity of > or = 1.020 and creatinine concentration of < or = 5 mg/dL; however, these patients were seriously ill or terminally ill.
Huang, Liping; Crino, Michelle; Wu, Jason Hy; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm Rc; Neal, Bruce; Petersen, Kristina S
2016-09-21
Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs better than existing equations to estimate mean population salt intake. The search strategy identified 538 records; 100 records were obtained for review in full text and 73 have been confirmed as eligible. In addition, 68 abstracts were identified, some of which may contain data eligible for inclusion. Individual participant data will be requested from the authors of eligible studies. Many equations for estimating salt intake from spot urine samples have been developed and validated, although most have been studied in very specific settings. This meta-analysis of individual participant data will enable a much broader understanding of the capacity for spot urine samples to estimate population salt intake.
Kokoski, R J; Jain, M
1975-03-01
Radioimmunoassay (RIA) and thin-layer chromatography (TLC) were compared for morphine detection in an actual narcotic clinic setting. A choice of urines from all those screened by TLC allowed a critical comparison as to actual use or non-use of narcotic drugs, rather than a sampling at random in which the question of possible false positives or negatives cannot be conclusively answered. Although RIA is more sensitive than TLC, its advantage is apparent only in those cases where urine specimens are difficult to obtain frequently regularly or where the use of morphine is suspected by the positive identification of quinine in urine that was morphine-negative by TLC. In a selected group of negative and positive specimens chosen without conscious bias, the two methods gave consistently similar results, indicating that the modified TLC method provided a few or no false positives or negatives if the negatives were from those cases that were not positive anytime up to 3-4 days before urine collection. We conclude that RIA can be of significant value as a supplement to a TLC screening program, without sacrificing the many advantages that TLC has to offer.
Chinese ‘low-tar’ cigarettes do not deliver lower levels of nicotine and carcinogens
Gan, Quan; Lu, Wei; Xu, Jiying; Li, Xinjian; Goniewicz, Maciej; Benowitz, Neal L
2010-01-01
Background Low-tar cigarette smoking is gaining popularity in China. The China National Tobacco Corporation (CNTC) promotes low-tar cigarettes as safer than regular cigarettes. Methods A total of 543 male smokers smoking cigarettes with different tar yields (15 mg, regular cigarettes, 10–13 mg low-tar cigarettes and <10 mg low-tar cigarettes) were recruited in Shanghai, China, who then completed a questionnaire on smoking behaviour and provided a urine sample for analysis of the nicotine metabolites cotinine and trans-3′-hydroxycotinine. A total of 177 urine samples were selected at random for the analysis of the carcinogens polycyclic aromatic hydrocarbon metabolites (PAHs) (1-hydroxypyrene, naphthols, hydroxyfluorenes and hydroxyphenanthrenes) and the tobacco specific nitrosamine 4-(methylnitrosamino)-1-(3-pyridyl)-butanone (NNK) metabolites, 4-(methylnitrosamino)-1-(3-pyridyl)-butanol (NNAL) and NNAL-glucuronide. Values were normalised by creatinine to correct for possible distortions introduced by dilution or concentration of the urine. Results Smokers of low-tar cigarettes smoked fewer cigarettes per day (p=0.001) compared to smokers of regular cigarettes. Despite this lower reported consumption, levels of cotinine, trans-3′-hydroxycotinine and PAHs in urine of people smoking low-tar cigarettes were not correlated with nominal tar delivery of the cigarettes they smoked. Urine concentrations of NNAL were higher in smokers of lower tar than higher tar cigarettes. Conclusions Chinese low-tar cigarettes do not deliver lower doses of nicotine and carcinogens than regular cigarettes, therefore it is unlikely that there would be any reduction in harm. CNTC's promotion of low-tar cigarettes as ‘less harmful’ is a violation of the World Health Organization Framework Convention on Tobacco Control, which China ratified in 2005. PMID:20507920
Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.
Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar
2015-11-15
In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of sequestering contaminants from environmental release and allows for targeted treatment of potential health hazards prior to agricultural application. The efficacy of pathogen and pharmaceutical inactivation, transformation or removal during urine nutrient recovery processes is thus briefly reviewed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita
2003-01-01
We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158
Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina
2016-09-01
Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.
Rovin, B H; Dooley, M A; Radhakrishnan, J; Ginzler, E M; Forrester, T D; Anderson, P W
2016-12-01
Tabalumab is a monoclonal antibody that neutralizes membrane and soluble B-cell activating factor. Two 52-week, randomized, double-blind, placebo controlled phase 3 trials evaluated the safety and efficacy of tabalumab in systemic lupus erythematosus. Patients with moderate to severe active systemic lupus erythematosus (without severe active lupus nephritis) were randomly assigned 1:1:1 to receive tabalumab (120 mg subcutaneously every 2 or 4 weeks) or placebo for 52 weeks. Serum creatinine concentration, estimated glomerular filtration rate, urine protein/creatinine ratio, renal flares and renal adverse events were determined monthly. Data were analyzed for the intent-to-treat population and for intent-to-treat patients with baseline urine protein/creatinine ratio >20 mg/mmol (intent-to-treat plus urine protein/creatinine ratio). The trials enrolled 2262 patients. At baseline, demographics, systemic lupus erythematosus disease activity, serum creatinine concentration, estimated glomerular filtration rate and urine protein/creatinine ratio were similar among the treatment arms (with the exception of disease duration). In the intent-to-treat and intent-to-treat plus urine protein/creatinine ratio populations, there were no differences between the arms in the baseline-to-endpoint change in serum creatinine concentration, glomerular filtration rate, urine protein/creatinine ratio, or renal flare rates. Tabalumab resulted in a significant B-cell reduction and decreased immunoglobulin G levels at both doses. Compared to placebo, tabalumab did not significantly affect the serum creatinine concentration, glomerular filtration rate, urine protein/creatinine ratio, or renal flare rates over 1 year in intent-to-treat or intent-to-treat plus urine protein/creatinine ratio patients. There were no significant renal safety signals.ClinicalTrials.gov identifiers: NCT01205438 and NCT01196091 Lupus (2016) 25, 1597-1601. © The Author(s) 2016.
A method for estimating radioactive cesium concentrations in cattle blood using urine samples.
Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji
2017-12-01
In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.
Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio
2013-01-01
Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.
Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan
2013-09-01
The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.
Effect of urine creatinine level during pregnancy on dipstick test.
Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori
2017-06-01
Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.
O'Brien, Kathryn; Stanton, Naomi; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C
2011-03-01
Due to the non-specific nature of symptoms of UTI in children and low levels of urine sampling, the prevalence of UTI amongst acutely ill children in primary care is unknown. To undertake an exploratory study of acutely ill children consulting in primary care, determine the feasibility of obtaining urine samples, and describe presenting symptoms and signs, and the proportion with UTI. Exploratory, observational study. Four general practices in South Wales. A total of 99 sequential attendees with acute illness aged less than five years. UTI defined by >10(5) organisms/ml on laboratory culture of urine. Urine samples were obtained in 75 (76%) children. Three (4%) met microbiological criteria for UTI. GPs indicated they would not normally have obtained urine samples in any of these three children. However, all had received antibiotics for suspected alternative infections. Urine sample collection is feasible from the majority of acutely ill children in primary care, including infants. Some cases of UTI may be missed if children thought to have an alternative site of infection are excluded from urine sampling. A larger study is needed to more accurately determine the prevalence of UTI in children consulting with acute illness in primary care, and to explore which symptoms and signs might help clinicians effectively target urine sampling.
Gouarne, C; Foury, A; Duclos, M
2004-10-01
Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.
Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio
2013-01-01
Background Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples’ storage or conditions for handling and DNA preservation and extraction methods. Methodology/Principal Findings We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patientś urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Conclusions/Significance Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used. PMID:23613907
Wang, Ying; Tong, Lili; Pak, Youngju; Andalibi, Ali; LaPage, Janine A.; Adler, Sharon G.
2016-01-01
Background We tested minocycline as an anti-proteinuric adjunct to renin-angiotensin-aldosterone system inhibitors (RAASi) in diabetic nephropathy (DN) and measured urinary biomarkers to evaluate minocycline’s biological effects. Methods Design: Prospective, single center, randomized, placebo-controlled, intention-to-treat pilot trial. Inclusion. Type 2 diabetes/DN; Baseline creatinine clearance > 30 mL/min; proteinuria ≥ 1.0 g/day; Age ≥30 years; BP <150/95 mm Hg; intolerant of/at maximum RAASi dose. Protocol. 3-wk screening; Baseline randomization; Urine and blood measures at months 1, 2, 4, and Month 6 study completion. Urine interleukin-6 (IL-6) and osteoprotegerin were measured in a subset. Primary outcome. Natural log of urine protein/creatinine (ln U P:Cr) ratio at Month 6 vs Baseline. Results 30 patients completed the study. The 15% decline in U P: Cr in minocycline patients (6 month P:Cr ÷ Baseline P:Cr, 0.85 vs. 0.92) was not significant (p = 0.27). Creatinine clearance did not differ in the 2 groups. Urine IL-6:Cr (p = 0.03) and osteoprotegerin/Cr (p = 0.046) decrements were significant. Minocycline modified the relationship between urine IL-6 and proteinuria, suggesting a protective biological effect. Conclusions Although the decline in U P:Cr in minocycline patients was not statistically significant, the significant differences in urine IL-6 and osteoprotegerin suggest that minocycline may confer cytoprotection in patients with DN, providing a rationale for further study. Trial Registration Clinicaltrials.gov NCT01779089 PMID:27019421
Protective effects of hydroxytyrosol on gentamicin induced nephrotoxicity in mice.
Chashmi, Nooshin Ahmadian; Emadi, Sarvenaz; Khastar, Hossein
2017-01-22
Gentamicin (GM) is an effective and common antibiotic against severe gram-negative infections. However, its nephrotoxic action has limited the extent of its use. The aim of this study was to investigate the protective effects of hydroxytyrosol (HT) on gentamicin induced nephrotoxicity in mice. Male mice (n = 27) were randomly assigned to three groups: (1) Sham, (2) GM (100 mg/kg for 7 days) (3) GM + HT (2 mg/kg BW; gastric gavages, for 7 days). 24-h urine samples were collected on day 8 and then animal were anesthetized. The blood and kidney tissue samples were collected. Gentamicin led to increase in plasma BUN and creatinine, fractional excretion of sodium and potassium and decrease in creatinine clearance and urine flow rate. SOD and GSH levels were reduced and MDA was increased in the GM group compared with the sham group. In GM + HT group, plasma BUN and creatinine, fractional excretion of Na, creatinine clearance and urine flow rate were decreased in contrast to GM group. Increase in SOD and GSH activity and decrease in MDA compared to GM group were seen. Findings suggest that HT partly protected the kidneys from gentamicin induced nephrotoxicity and it is partly due to antioxidant effect of HT. Copyright © 2016 Elsevier Inc. All rights reserved.
Aklin, Will M.; Wong, Conrad J.; Hampton, Jacqueline; Svikis, Dace S.; Stitzer, Maxine L.; Bigelow, George E.; Silverman, Kenneth
2014-01-01
This study evaluated the long-term effects of a Therapeutic Workplace social business on drug abstinence and employment. Pregnant and postpartum women (N=40) enrolled in methadone treatment were randomly assigned to a Therapeutic Workplace or Usual Care Control group. Therapeutic Workplace participants could work weekdays in training and then as employees of a social business, but were required to provide drug-free urine samples to work and maintain maximum pay. Three-year outcomes were reported previously. This paper reports 4- to 8- year outcomes. During year 4 when the business was open, Therapeutic Workplace participants provided significantly more cocaine- and opiate-negative urine samples than controls; reported more days employed, higher employment income, and less money spent on drugs. During the 3 years after the business closed, Therapeutic Workplace participants only reported higher income than controls. A Therapeutic Workplace social business can maintain long-term abstinence and employment, but additional intervention may be required to sustain effects. PMID:25124257
Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.
Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan
2017-12-01
Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.
ERIC Educational Resources Information Center
Preston, Kenzie L.; Ghitza, Udi E.; Schmittner, John P.; Schroeder, Jennifer R.; Epstein, David H.
2008-01-01
We compared two strategies of prize-based contingency management (CM) in methadone-maintained outpatients. Urine was tested thrice weekly for 5 weeks pre-CM, 12 weeks CM, and 8 weeks post-CM. Participants were randomly assigned to a cocaine contingency (four prize draws for each cocaine-negative urine, N = 29) or an opiate-cocaine contingency (one…
Urine phenobarbital drug screening: potential use for compliance assessment in neonates.
Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P
2012-02-01
This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.
The effect of substrate composition and storage time on urine specific gravity in dogs.
Steinberg, E; Drobatz, K; Aronson, L
2009-10-01
The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.
Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... A clean-catch urine sample is needed. The clean-catch method is used to prevent germs from the penis or vagina from getting ...
Everly, Jeffrey J; DeFulio, Anthony; Koffarnus, Mikhail N; Leoutsakos, Jeannie-Marie S; Donlin, Wendy D; Aklin, Will M; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E; Silverman, Kenneth
2011-07-01
Naltrexone can be used to treat opioid dependence, but patients refuse to take it. Extended-release depot formulations may improve adherence, but long-term adherence rates to depot naltrexone are not known. This study determined long-term rates of adherence to depot naltrexone and whether employment-based reinforcement can improve adherence. Participants who were inducted onto oral naltrexone were assigned randomly to contingency (n = 18) or prescription (n = 17) groups. Participants were offered six depot naltrexone injections and invited to work at the therapeutic workplace on week days for 26 weeks, where they earned stipends for participating in job skills training. Contingency participants were required to accept naltrexone injections to maintain workplace access and to maintain maximum pay. Prescription participants could work independently of whether they accepted injections. The therapeutic workplace, a model employment-based intervention for drug addiction and unemployment. Opioid-dependent unemployed adults. Depot naltrexone injections accepted and opiate-negative urine samples. Contingency participants accepted significantly more naltrexone injections than prescription participants (81% versus 42%), and were more likely to accept all injections (66% versus 35%). At monthly assessments (with missing urine samples imputed as positive), the groups provided similar percentages of samples negative for opiates (74% versus 62%) and for cocaine (56% versus 54%). Opiate-positive samples were more likely when samples were also positive for cocaine. Employment-based reinforcement can maintain adherence to depot naltrexone. Future research should determine whether persistent cocaine use compromises naltrexone's effect on opiate use. Workplaces may be useful for promoting sustained adherence to depot naltrexone. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.
Lalley-Chareczko, Linden; Clark, Devon; Zuppa, Athena F; Moorthy, Ganesh; Conyngham, Caitlin; Mounzer, Karam; Koenig, Helen
2017-01-01
Emtricitabine/tenofovir disoproxil fumarate (FTC/TDF; Truvada ® ) given as pre-exposure prophylaxis (PrEP) successfully blocks HIV when taken once daily prior to potential HIV exposure. A 22-year-old male reported difficulty swallowing FTC/TDF for PrEP and subsequently began chewing the FTC/TDF tablets. Monthly urine samples assessed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) indicated tenofovir levels >1,000 ng/ml, indicative of protection from HIV acquisition, over a 48-week period. Data from observational studies of HIV-positive patients details the successful treatment of HIV using crushed FTC/TDF delivered via feeding and gastronomy tubes while small, randomized trials of healthy volunteers demonstrate bioequivalence between whole and crushed FTC/TDF.
Liu, Guangmang; Xiao, Liang; Fang, Tingting; Cai, Yimin; Jia, Gang; Zhao, Hua; Wang, Jing; Chen, Xiaoling; Wu, Caimei
2014-01-01
This study aimed to examine the effect of pea fiber (PF) and wheat bran fiber (WF) supplementation in rat metabolism. Rats were assigned randomly to one of three dietary groups and were given a basal diet containing 15% PF, 15% WF, or no supplemental fiber. Urine and plasma samples were analyzed by NMR-based metabolomics. PF significantly increased the plasma levels of 3-hydroxybutyrate, and myo-inositol as well as the urine levels of alanine, hydroxyphenylacetate, phenylacetyglycine, and α-ketoglutarate. However, PF significantly decreased the plasma levels of isoleucine, leucine, lactate, and pyruvate as well as the urine levels of allantoin, bile acids, and trigonelline. WF significantly increased the plasma levels of acetone, isobutyrate, lactate, myo-inositol, and lipids as well as the urine levels of alanine, lactate, dimethylglycine, N-methylniconamide, and α-ketoglutarate. However, WF significantly decreased the plasma levels of amino acids, and glucose as well as the urine levels of acetate, allantoin, citrate, creatine, hippurate, hydroxyphenylacetate, and trigonelline. Results suggest that PF and WF exposure can promote antioxidant activity and can exhibit common systemic metabolic changes, including lipid metabolism, energy metabolism, glycogenolysis and glycolysis metabolism, protein biosynthesis, and gut microbiota metabolism. PF can also decrease bile acid metabolism. These findings indicate that different fiber diet may cause differences in the biofluid profile in rats. PMID:25541729
Scargill, J J; Reed, P; Kane, J
2013-01-01
Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.
Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.
Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E
2002-12-01
Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.
Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad
2018-05-27
The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.
Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...
Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I.; Dwyer, Karen M.; Saffery, Richard
2018-01-01
Aim To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. Background DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. Methods QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Results Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0–0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0–9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0–17.7μg/mL and 0–1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. Conclusion High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease. PMID:29462136
Lecamwasam, Ashani; Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I; Dwyer, Karen M; Saffery, Richard
2018-01-01
To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0-0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0-9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0-17.7μg/mL and 0-1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease.
Trace Chemical Analysis Methodology
1980-04-01
oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine
Al-Khalidi, Banaz; Chiu, Winnie; Rousseau, Dérick; Vieth, Reinhold
2015-09-01
To assess the bioavailability and safety of vitamin D3 from fortified mozzarella cheese baked on pizza. In a randomized, double-blind trial, 96 apparently healthy, ethnically diverse adults were randomized to consume 200 IU or 28 000 IU vitamin D3 fortified mozzarella cheese with pizza once weekly for a total of 8 weeks. Blood and urine samples were collected at baseline (week 1) and final (week 10) visits for serum 25-hydroxyvitamin D and other biochemical measures. The primary outcome compared serum 25-hydroxyvitamin D between groups at 10 weeks. The secondary outcome evaluated the safety of vitamin D dosing protocol as measured by serum and urine calcium, phosphate, creatinine, and serum parathyroid hormone (PTH). Serum 25-hydroxyvitamin D increased by 5.1 ± 11 nmol/L in the low-dose group (n = 47; P = 0.003), and by 73 ± 22 nmol/L in the high-dose group (n = 49; P < 0.0001). None of the subjects in either group developed any adverse events during the supplementation protocol. Serum PTH significantly decreased in the high-dose group only (P < 0.05). Vitamin D3 is safe and bioavailable from fortified mozzarella cheese baked on pizza.
Ding, Chunguang; Pan, Yajuan; Zhang, Aihua; Zhu, Chun; Liu, Deye; Xu, Guang; Zheng, Yuxin; Yan, Huifang
2015-12-01
To investigate the distribution of rubidium (Rb), cesium (Cs), beryllium (Be), strontium (Sr), and barium (Ba) in blood and urine in general Chinese population. A total of 18 120 subjects aged 6~60 years were enrolled from 24 regions in 8 provinces in Eastern, Central, and Western China from 2009 to 2010 based on the method of cluster random sampling. Questionnaire survey was conducted to collect the data on living environment and health status. Blood and urine samples were collected from these subjects, and the levels of Rb, Cs, Be, Sr, and Ba in these samples were determined by inductively coupled plasma mass spectrometry. The distribution of these elements in blood and urine in male or female subjects living in different regions was analyzed statistically. In the general Chinese population, the concentration of Be in the whole blood was below the detection limit (0.06 μg/L); the geometric mean (GM) of Ba in the whole blood was below the detection limit (0.45 μg/L), with the 95th percentile (P95)of 1.37 μg/L; the GMs (95% CI)of Rb, Cs, and Sr in the whole blood were 2 374(2 357~2 392) μg/L, 2.01 (1.98~2.05) μg/L, and 23.5 (23.3~23.7) μg/L, respectively; in males and females, the GMs (95%CI)of blood Rb, Cs, and Sr were 2 506 (2 478~2 533) μg/L and 2 248 (2 227~2 270) μg/L, 1.88 (1.83~1.94) μg/L and 2.16 (2.11~2.20) μg/L, and 23.4 (23.1~23.7) μg/L and 23.6 (23.3~23.9) μg/L, respectively(P<0.01, P>0.05, and P>0.05). In the general Chinese population, the GM of urine Be was below the detection limit (0.06 μg/L), while the GMs (95%CI)of urine Rb, Cs, Sr, and Ba were 854 (836~873) μg/L, 3.65 (3.56~3.74) μg/L, 39.5 (38.4~40.6) μg/L, and 1.10 (1.07~1.12) μg/L, respectively; in males and females, the GMs (95%CI)of urine Rb, Cs, Sr, and Ba were 876 (849~904) μg/L and 832 (807~858) μg/L, 3.83 (3.70~3.96) μg/L and 3.47 (3.35~3.60) μg/L, 42.5 (40.9~44.2) μg/L and 36.6 (35.1~38.0) μg/L, and 1.15 (1.12~1.19) μg/L and 1.04 (1.01~1.07) μg/L, respectively (all P< 0.01). Correlation analyses showed that there were weak correlations between blood Rb and urine Rb (r=0.197)and between blood Sr and urine Sr (r=0.180), but a good correlation between blood Cs and urine Cs (r=0.487). The levels of Rb, Cs, Be, Sr, and Ba in the general Chinese population are similar to those reported in other countries, and there is a significant difference in the concentration of each element among the populations living in different regions, as well as significant differences in blood Rb, urine Rb, urine Cs, urine Sr, and urine Ba between males and females.
Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D
2016-01-15
To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.
García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime
2017-06-01
Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.
Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C
2010-03-11
Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.
Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís
2015-10-01
A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.
Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E
2015-10-01
To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.
Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue
2012-01-01
19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.
Urinary Ca+2; Kidney stones - calcium in urine; Renal calculi - calcium in your urine; Parathyroid - calcium in urine ... A 24-hour urine sample is most often needed: On day 1, urinate into the toilet when you wake up in the morning. ...
... tubular epithelial casts; Waxy casts; Casts in the urine; Fatty casts; Red blood cell casts; White blood ... The urine sample you provide may need to be from your first morning urine. The sample needs to be ...
... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...
Almaani, Salem; Hebert, Lee A.; Rovin, Brad H.
2017-01-01
Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β-2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid–mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. PMID:28104821
Almaani, Salem; Hebert, Lee A; Rovin, Brad H; Birmingham, Daniel J
2017-05-01
Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β -2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid-mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. Copyright © 2017 by the American Society of Nephrology.
Beckmann, Manfred; Enot, David P; Overy, David P; Scott, Ian M; Jones, Paul G; Allaway, David; Draper, John
2010-04-01
Selective breeding of dogs has culminated in a large number of modern breeds distinctive in terms of size, shape and behaviour. Inadvertently, a range of breed-specific genetic disorders have become fixed in some pure-bred populations. Several inherited conditions confer chronic metabolic defects that are influenced strongly by diet, but it is likely that many less obvious breed-specific differences in physiology exist. Using Labrador retrievers and miniature Schnauzers maintained in a simulated domestic setting on a controlled diet, an experimental design was validated in relation to husbandry, sampling and sample processing for metabolomics. Metabolite fingerprints were generated from 'spot' urine samples using flow injection electrospray MS (FIE-MS). With class based on breed, urine chemical fingerprints were modelled using Random Forest (a supervised data classification technique), and metabolite features (m/z) explanatory of breed-specific differences were putatively annotated using the ARMeC database (http://www.armec.org). GC-MS profiling to confirm FIE-MS predictions indicated major breed-specific differences centred on the metabolism of diet-related polyphenols. Metabolism of further diet components, including potentially prebiotic oligosaccharides, animal-derived fats and glycerol, appeared significantly different between the two breeds. Analysis of the urinary metabolome of young male dogs representative of a wider range of breeds from animals maintained under domestic conditions on unknown diets provided preliminary evidence that many breeds may indeed have distinctive metabolic differences, with significant differences particularly apparent in comparisons between large and smaller breeds.
Zarban, Asghar; Toroghi, Mahsa Mostafavi; Asli, Marziye; Jafari, Masumeh; Vejdan, Morteza; Sharifzadeh, Gholamreza
2015-05-01
After delivery and birth, mothers and neonates are exposed to oxidative stress. The present study examined the effect of supplementation of the diet of breastfeeding mothers with vitamin C and E to improve the antioxidant content of breastmilk and evidence of antioxidant activity in infant urine. The subjects were 60 healthy lactating breastfeeding mothers and their infants 1-6 months of age. They were randomly allocated to a control group (n=30) consuming a free diet or an experimental group (n=30) consuming a free diet supplemented each day with effervescent tablets of vitamin C (500 mg) and chewable tablets of vitamin E (100 IU). After 30 days, the total antioxidant content of the mothers' breastmilk and evidence of antioxidant activity in the infants' urine were measured by the ferric reducing/antioxidant power assay. The free radical scavenging activity of the urine samples was measured by the α,α-diphenyl-β-picrylhydrazyl method. Differences pre- and postintervention were compared within and between the groups. Significantly higher levels of antioxidants in the breastmilk (610±295.5 to 716±237.5 μmol/L) and infant urine (43.2±21.8 to 75.0±49.2 μmol/mg creatinine) were observed in the experimental group over the control group (p<0.05). A significant increase in evidence of free radical scavenging in infant urine was observed in the experimental group after 30 days of supplementation by mothers (p<0.05). Consumption of vitamin C and E supplements appears to have a positive effect on total antioxidant content of breastmilk and evidence of antioxidant activity in infant urine.
Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D
2017-09-01
Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.
Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard
2016-06-01
The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.
Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...
Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares
1998-01-01
For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407
Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.
Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj
2016-01-01
To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.
Collection and storage of urine specimens for measurement of urolithiasis risk factors.
Wu, Wenqi; Yang, Dong; Tiselius, Hans-Goran; Ou, Lili; Mai, Zanlin; Chen, Kang; Zhu, Hanliang; Xu, Shaohong; Zhao, Zhijian; Zeng, Guohua
2015-02-01
To evaluate how different methods for storage and preservation of urine samples affected the outcome of analysis of risk factors for stone formation. Spot urine samples were collected from 21 healthy volunteers. Each fresh urine sample was divided into ten 10-mL aliquots: 2 without preservative, 2 with thymol, 2 with toluene, 2 with hydrochloric acid (HCl), and 2 with sodium azide. One sample of each pair was stored at 4 °C and the other at room temperature. The concentrations of calcium, magnesium, sodium, phosphate, urate, oxalate, citrate, and pH in each urine sample were analyzed immediately after collection (0 hour) and after 24 and 48 hours. There were no significant differences in calcium, oxalate, magnesium, phosphate, sodium, urate or pH (without acidification) between samples with different preservation methods (P >.05). Urinary citrate, however, was significantly lower in the urine collected with HCl than when other preservatives were used, both at room temperature and at 4 °C. Urine pH was significantly higher after 48 hours than after 24 hours, whether the samples were stored at room temperature or at 4 °C. Antibacterial preservatives (eg, thymol or toluene) can be recommended as preservatives for 24-hour urine collections. Ideally, the samples should be stored at 4 °C. When HCl is used as a preservative, it seems essential to neutralize the samples before analysis. This is particularly obvious with the chromatographic method used for analysis of citrate that was used in this study. Copyright © 2015 Elsevier Inc. All rights reserved.
Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio
2018-04-01
Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.
Sample preparation and storage can change arsenic speciation in human urine.
Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C
1999-11-01
Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.
2012-08-22
urine drug tesL~ (UDTs). A BUM ED Publication wi ll follow the lnterim Guidance for sustainment. Two training programs have also been created to...line DEPARTMENT OF DEFENSE 800.424.9098 Fraud, Waste, Mismanagement, Abuse of Authority Suspected Threats to Homeland Security Unauthorized...determined how many Service members were required to be interviewed, then we applied a simple random sample approach to determine the Service members we
NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...
Urine sampling and collection system
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.
1971-01-01
This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.
Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie
2010-02-01
NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.
Kordass, Ulrike; Carlson, Regina; Stein, Veronika Maria; Tipold, Andrea
2016-01-08
The purpose of this study was to prove the hypothesis that C-reactive protein (CRP) and nerve growth factor (NGF) may be potential biomarkers for lower urinary tract disorders and may be able to distinguish between micturition dysfunctions of different origin in dogs with spinal cord diseases. NGF- and CRP- concentrations were measured in serum and urine samples using specific ELISA-Kits. Results in urine were standardized by urine-creatinine levels. CRP in serum was detectable in 32/76 and in urine samples in 40/76 patients. NGF could be measured in all serum and in 70/76 urine samples. Urinary CRP concentrations were significantly higher in dogs with micturition dysfunction (p = 0.0009) and in dogs with different neurological diseases (p = 0.0020) compared to the control group. However, comparing dogs with spinal cord disorders with and without associated micturition dysfunction no significant difference could be detected for NGF and CRP values in urine or serum samples. Additionally, levels did not decrease significantly, when measured at the time when the dogs regained the ability to urinate properly (urinary NGF p = 0.7962; urinary CRP p = 0.078). Urine samples with bacteria and/or leukocytes had no significant increase in urinary NGF (p = 0.1112) or CRP (p = 0.0534) concentrations, but higher CRP-levels in urine from dogs with cystitis were found compared to dogs without signs of cystitis. From these data we conclude that neither CRP nor NGF in urine or serum can be considered as reliable biomarkers for micturition disorders in dogs with spinal cord disorders in a clinical setting, but their production might be part of the pathogenesis of such disorders. Significantly higher levels of CRP could be found in the urine of dogs with micturition dysfunctions compared to control dogs. This phenomenon could potentially be explained by unspecific extrahepatic CRP production by smooth muscle cells in the dilated bladder.
Del Coso, Juan; Muñoz, Gloria; Muñoz-Guerra, Jesús
2011-08-01
The aim of this investigation was to determine the use of caffeine by athletes after its removal from the World Anti-Doping Agency list. For this purpose, we measured the caffeine concentration in 20 686 urine samples obtained for doping control from 2004 to 2008. We utilized only urine samples obtained after official national and international competitions. Urine caffeine concentration was determined using alkaline extraction followed by gas chromatography-mass spectrometry. The limit of detection (LOD) was set at 0.1 µg·mL(-1). The percentage of urine samples below the LOD was 26.2%; the remaining 73.8% of the urine samples contained caffeine. Most urine samples (67.3%) had urinary caffeine concentrations below 5 µg·mL(-1). Only 0.6% of urine samples exceeded the former threshold for caffeine doping (12 µg·mL(-1)). Triathlon (3.3 ± 2.2 µg·mL(-1)), cycling (2.6 ± 2.0 µg·mL(-1)), and rowing (1.9 ± 1.4 µg·mL(-1)) were the sports with the highest levels of urine caffeine concentration; gymnastics was the sport with the lowest urine caffeine concentration (0.5 ± 0.4 µg·mL(-1)). Older competitors (>30 y) had higher levels of caffeine in their urine than younger competitors (<20 y; p < 0.05); there were no differences between males and females. In conclusion, 3 out of 4 athletes had consumed caffeine before or during sports competition. Nevertheless, only a small proportion of these competitors (0.6%) had a urine caffeine concentration higher than 12 µg·mL(-1). Endurance sports were the disciplines showing the highest urine caffeine excretion after competition.
Montagna, M; Stramesi, C; Vignali, C; Groppi, A; Polettini, A
2000-01-10
A sensitive GC-MS method for the simultaneous determination of opiates, cocaine, and metabolites in hair at a cut-off level of 0.1 ng/mg was adopted to assess past exposure to these drugs in applicants for driving licenses with a history of drug use. The sampling protocol consisted of collection of one hair (sample A, 5-cm length) and one urine sample. When hair and urine (EMIT Syva, cut-off levels: 0.3 mg/l for opiates, 0.15 mg/l for cocaine, GC-MS confirmation of positives) were both positive or negative the protocol was concluded. In the other cases, the assessment of 'current exposure' to drugs was carried out, in order to avoid seriated random urinalysis, by collecting a second hair sample (sample B) 6 weeks later and analysing the proximal 1-cm segment. Out of the 214 'A' hair samples analyzed, 14 (6.5%) tested positive for morphine and/or 6-acetylmorphine (6AM), and 26 (12%) for cocaine and/or benzoylecgonine (BE), whereas none of the samples tested positive for both drugs. Levels between 0.1 and 1 ng/mg of the single analytes were found in eight out of the 14 morphine-6AM positives (57%) and in 18 out of the 26 cocaine-BE positives (69%). The time course of positive cases showed a progressive decrease of morphine-6AM positives and a corresponding increase of cocaine-BE positives within the study period September 1995-February 1999. No cases with positive urine and negative hair were observed. Among the 40 positive cases, seven (four and three for opiates and cocaine, respectively) were found to be 'currently exposed to drug', four by urinalysis (three and one) and three by analysis of the hair sample B (1 and 2).
Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S
2016-01-01
Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.
Uysal, Deniz; Karadaş, Cennet; Kara, Derya
2017-05-01
A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.
Is a pre-analytical process for urinalysis required?
Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole
2017-10-01
For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.
[Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].
Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo
2016-03-01
The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.
Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R
2014-07-01
To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.
Baixench, M T; Al-Sheikh, M; Paugam, A
2005-01-01
The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.
Detection of human papillomavirus DNA in urine. A review of the literature.
Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P
2012-05-01
The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.
Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin
2016-03-01
Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Urinary asbestos fibers and inorganic particles in past asbestos workers.
Zaina, Sara; Mastrangelo, Giuseppe; Ballarin, Maria Nicoletta; Scoizzato, Luca; Carradori, Giorgio; Fedeli, Ugo; Capella, Silvana; Belluso, Elena
2016-05-03
To assess the validity of the procedure as a test of asbestos exposure, we compared urinary asbestos fibers with occupational and environmental exposure data in a random sample of 48 subjects with high past asbestos exposure. Occupational and environmental exposure was estimated on questionnaire, pleural plaques were diagnosed with computed tomography, and inorganic fibers and particles were identified by scanning electron microscope with an energy-dispersive spectrometry. Few urinary asbestos fibers (in 15% of workers and 17% of cases with pleural plaques) and high amount of urinary silicate (particularly nonfibrous particles) were detected. Asbestos undergoes dissolution in lung tissues, but the secondary minerals are largely unknown. These materials, possibly nonfibrous silicates or metals, could be excreted with urine. Therefore, another study including a control group is warranted to discriminate the occupational origin of minerals in the urine.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...
Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki
2011-01-01
To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.
Poling, James; Oliveto, Alison; Petry, Nancy; Sofuoglu, Mehmet; Gonsai, Kishorchandra; Gonzalez, Gerardo; Martell, Bridget; Kosten, Thomas R
2006-02-01
No effective pharmacotherapies exist for cocaine dependence, although contingency management (CM) has demonstrated efficacy. To compare the efficacy of bupropion hydrochloride and CM for reducing cocaine use in methadone hydrochloride-maintained individuals. This 25-week, placebo-controlled, double-blind trial randomly assigned participants to 1 of 4 treatment conditions: CM and placebo (CMP), CM and 300 mg/d of bupropion hydrochloride (CMB), voucher control and placebo (VCP), or voucher control and bupropion (VCB). Outpatient clinic at the Veterans Affairs Connecticut Healthcare System. A total of 106 opiate-dependent, cocaine-abusing individuals. All study participants received methadone hydrochloride (range, 60-120 mg). Participants receiving bupropion hydrochloride were given 300 mg/d beginning at week 3. In the CM conditions, each urine sample negative for both opioids and cocaine resulted in a monetary-based voucher that increased for consecutively drug-free urine samples during weeks 1 to 13. Completion of abstinence-related activities also resulted in a voucher. During weeks 14 to 25, only completion of activities was reinforced in the CM group, regardless of sample results. The voucher control groups received vouchers for submitting urine samples, regardless of results, throughout the study. Thrice-weekly urine toxicologic test results for cocaine and heroin. Groups did not differ in baseline characteristics or retention rates. Opiate use decreased significantly, with all treatment groups attaining equivalent amounts of opiate use at the end of the study. In the CMB group, the proportion of cocaine-positive samples significantly decreased during weeks 3 to 13 (P<.001) relative to week 3 and remained low during weeks 14 to 25. In the CMP group, cocaine use significantly increased during weeks 3 to 13 (P<.001) relative to week 3, but then cocaine use significantly decreased relative to the initial slope during weeks 14 to 25 (P<.001). In contrast, by treatment end, the VCB and VCP groups showed no significant improvement in cocaine use. These findings suggest that combining CM with bupropion for the treatment of cocaine addiction may significantly improve outcomes relative to bupropion alone.
Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi
2018-07-01
The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.
Stability studies of amphetamine and ephedrine derivatives in urine.
Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R
2006-10-20
Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.
Albumin adsorption onto surfaces of urine collection and analysis containers☆
Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg
2017-01-01
Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540
Albumin adsorption onto surfaces of urine collection and analysis containers.
Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg
2014-04-20
Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.
Fizazi, Karim; Bosserman, Linda; Gao, Guozhi; Skacel, Tomas; Markus, Richard
2009-08-01
Patients with bone metastases have high rates of RANKL driven bone resorption and an increased risk of skeletal morbidity. Osteoclast mediated bone resorption can be assessed by measuring urine N-telopeptide and can be inhibited by denosumab, a fully human antibody against RANKL. Eligible patients (111) had bone metastases from prostate cancer, other solid tumors or multiple myeloma, 1 or more bone lesions and urine N-telopeptide greater than 50 nM bone collagen equivalents per mM creatinine (urine N-telopeptide greater than 50) despite the use of intravenous bisphosphonates. Patients were stratified by cancer type and screening urine N-telopeptide, and randomized to continue intravenous bisphosphonates every 4 weeks or receive 180 mg subcutaneous denosumab every 4 weeks or 180 mg every 12 weeks. The primary end point was the proportion of patients with urine N-telopeptide less than 50 at week 13. We report the efficacy results for the subset of patients with prostate cancer. Patients with prostate cancer represented 45% (50 of 111) of the study population. At week 13, 22 of 32 (69%) patients in the denosumab arms had urine N-telopeptide less than 50 vs 3 of 16 (19%) in the intravenous bisphosphonates cohort. At week 25, 22 of 32 (69%) denosumab treated patients continued to have urine N-telopeptide less than 50 vs 5 of 16 (31%) treated with intravenous bisphosphonates. Grade 4, asymptomatic, reversible hypophosphatemia, possibly related to denosumab, was reported in 1 patient. In patients with prostate cancer related bone metastases and increased urine N-telopeptide despite intravenous bisphosphonate treatment, denosumab normalized urine N-telopeptide levels more frequently than ongoing intravenous bisphosphonates.
Solid phase extraction of 2,4-D from human urine.
Thompson, T S; Treble, R G
1996-10-01
A method for determining urinary concentrations of 2,4-D in samples collected from non-occupationally, environmentally exposed individuals was developed. The 2,4-D was extracted from fortified human urine samples using octadecylsilane solid phase extraction cartridges. The average percent recovery for urine samples spiked at 2 and 20 ng/mL was 100% and 93%, respectively. The method detection limit was estimated to be 0.75 ng of 2,4-D per mL of urine based on a 10 mL sample size. The potential use of 2,4-dichlorophenylacetic acid as a surrogate standard was also investigated.
Extremes of urine osmolality - Lack of effect on red blood cell survival
NASA Technical Reports Server (NTRS)
Leon, H. A.; Fleming, J. E.
1980-01-01
Rats were allowed a third of normal water intake for 20 days, and food consumption decreased. The reticulocyte count indicated a suppression of erythropoiesis. Urine osmolality increased from 2,000 mosmol/kg to 3,390 mosmol/kg. Random hemolysis and senescence of a cohort of red blood cell (RBC) previously labeled with (2-(C-14)) glycine was monitored via the production of (C-14)O. Neither hemolysis nor senescence was affected. Following water restriction, the polydipsic rats generated a hypotonic urine. Urine osmolality decreased to 1,300 mosmol/kg for at least 6 days; a reticulocytosis occurred, but RBC survival was unaffected. These results contradict those previously reported, which suggest that RBC survival is influenced by the osmotic stress imposed on the RBC by extremes of urine tonicity. This discrepancy, it is concluded, is due to differences in the methods employed for measuring RBC survival. The random-labeling technique employed previously assumes a steady state between RBC production and destruction. The cohort-labeling technique used here measures hemolysis and senescence independent of changes in RBC production, which is known to be depressed by fasting.
Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S
2010-02-15
Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC-MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the 'non-specific loss' of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC-MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the 'non-specific binding' of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. beta-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of beta-cyclodextrin to untreated urine samples does not recover the 'lost' analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200-20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from -3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid-liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at < or =-60 degrees C and for at least 3 months when stored at < or =-60 degrees C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples. Copyright 2010. Published by Elsevier B.V.
Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed
2014-10-31
In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Gambelunghe, Cristiana; Sommavilla, Marco; Rossi, Ruggero
2002-12-01
The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. Copyright 2002 John Wiley & Sons, Ltd.
Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo
2018-01-01
This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.
Frias, Rafael; Sankari, Satu; Westermarck, Elias
2004-01-01
The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.
Wozniak, Barbara; Matraszek-Zuchowska, Iwona; Witek, Sebastian; Zmudzki, Jan; Posyniak, Andrzej
2018-01-15
Thyreostatic compounds, such as thiouracil, are orally active drugs that can be used to increase the weight of cattle before slaughter. Due to potentially teratogenic and carcinogenic effects of their residues on public health, the use of thyreostats in animal production has been banned in the European Union since 1981. Systematic detection of low concentrations of thiouracil in the urine of livestock in many countries is believed to be of endogenous origin due to the use of Brassicaceae plants in the animal diet. Therefore, the purpose of the study was to determine the effects of diets rich in rapeseed meal on formation of thiouracil in urine and milk of dairy cows. For two weeks three cows were subjected to a diet supplemented with rapeseed at 30%, compared to the control cattle diet which contained up to 11% rapeseed. During the experiment, samples of urine and milk were collected and analysed by LC-MS/MS. The increase and decrease of thiouracil concentration in urine samples in different animals was individual and cyclic. The highest concentration of natural thiouracil determined in urine was 3.61 μg l -1 . It has been found that endogenous thiouracil exists in two tautomeric forms. A few days of storage of frozen urine samples affected the stability of natural thiouracil, whereas an acidic medium improved the stability of the compound and its isomer, which remained stable even after two months of storage at temperatures below -18°C. Due to the instability of thiouracil, urine samples upon sampling should be delivered to the laboratory as soon as possible or properly preserved. In milk samples, thiouracil was not found above the decision limit of the applied method of 0.63 μg l -1 . Preliminary studies have shown that faecal examination for banned thiouracil can be a complementary test for urine samples, and may be helpful in determining the origin of the compound present in urine.
Sheedy, John R; Gooley, Paul R; Nahid, Amsha; Tull, Dedreia L; McConville, Malcolm J; Kukuljan, Sonja; Nowson, Caryl A; Daly, Robin M; Ebeling, Peter R
2014-11-01
The musculoskeletal benefits of calcium and vitamin-D3 supplementation and exercise have been extensively studied, but the effect on metabolism remains contentious. Urine samples were analyzed by (1)H-NMR spectroscopy from participants recruited for an 18-month, randomized controlled trial of a multi-component exercise program and calcium and vitamin-D3 fortified milk consumption. It was shown previously that no increase in musculoskeletal composition was observed for participants assigned to the calcium and vitamin-D3 intervention, but exercise resulted in increased bone mineral density, total lean body mass, and muscle strength. Retrospective metabolomics analysis of urine samples from patients involved in this study revealed no distinct changes in the urinary metabolome in response to the calcium and vitamin-D3 intervention, but significant changes followed the exercise intervention, notably a reduction in creatinine and an increase in choline, guanidinoacetate, and hypoxanthine (p < 0.001, fold change > 1.5). These metabolites are intrinsically involved in anaerobic ATP synthesis, intracellular buffering, and methyl-balance regulation. The exercise intervention had a marked effect on the urine metabolome and markers of muscle turnover but none of these metabolites were obvious markers of bone turnover. Measurement of specific urinary exercise biomarkers may provide a basis for monitoring performance and metabolic response to exercise regimes.
Appannanavar, Suma B; Biswal, Manisha; Rajkumari, Nonika; Mohan, Balvinder; Taneja, Neelam
2013-01-01
Urine culture is a gold standard in the diagnosis of urinary tract infection. Clean catch midstream urine collection and prompt transportation is essential for appropriate diagnosis. Improper collection and delay in transportation leads to diagnostic dilemma. In developing countries, higher ambient temperatures further complicate the scenario. Here, we have evaluated the role of boric acid as a preservative for urine samples prior to culture in female patients attending outpatient department at our center. Consecutive 104 urine samples were cultured simultaneously in plain uricol (Control-C) and boric acid containing tubes from Becton Dickinson urine culture kit (Boric acid group-BA). In the real-time evaluation, we found that in almost 57% (59/104) of the urine samples tested, it was more effective in maintaining the number of the organisms as compared to samples in the container without any preservative. Our in vitro study of simulated urine cultures revealed that urine samples could be kept up to 12 h before culture in the preservative without any inhibitory effect of boric acid. Though the use of boric acid kit may marginally increase the initial cost but has indirect effects like preventing delays in treatment and avoidance of false prescription of antibiotics. If the man-hours spent on repeat investigations are also taken into consideration, then the economic cost borne by the laboratory would also decrease manifold with the use of these containers.
Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.
Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A
2011-03-01
The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.
Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda
2012-01-01
Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012
COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES
To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...
Mengual, Lourdes; Burset, Moisès; Ribal, María José; Ars, Elisabet; Marín-Aguilera, Mercedes; Fernández, Manuel; Ingelmo-Torres, Mercedes; Villavicencio, Humberto; Alcaraz, Antonio
2010-05-01
To develop an accurate and noninvasive method for bladder cancer diagnosis and prediction of disease aggressiveness based on the gene expression patterns of urine samples. Gene expression patterns of 341 urine samples from bladder urothelial cell carcinoma (UCC) patients and 235 controls were analyzed via TaqMan Arrays. In a first phase of the study, three consecutive gene selection steps were done to identify a gene set expression signature to detect and stratify UCC in urine. Subsequently, those genes more informative for UCC diagnosis and prediction of tumor aggressiveness were combined to obtain a classification system of bladder cancer samples. In a second phase, the obtained gene set signature was evaluated in a routine clinical scenario analyzing only voided urine samples. We have identified a 12+2 gene expression signature for UCC diagnosis and prediction of tumor aggressiveness on urine samples. Overall, this gene set panel had 98% sensitivity (SN) and 99% specificity (SP) in discriminating between UCC and control samples and 79% SN and 92% SP in predicting tumor aggressiveness. The translation of the model to the clinically applicable format corroborates that the 12+2 gene set panel described maintains a high accuracy for UCC diagnosis (SN = 89% and SP = 95%) and tumor aggressiveness prediction (SN = 79% and SP = 91%) in voided urine samples. The 12+2 gene expression signature described in urine is able to identify patients suffering from UCC and predict tumor aggressiveness. We show that a panel of molecular markers may improve the schedule for diagnosis and follow-up in UCC patients. Copyright 2010 AACR.
Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent
2005-09-15
An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S
2015-04-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.
2014-01-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921
A novel way to monitor urine concentration: fluorescent concentration matrices.
Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton
2015-01-01
The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.
2012-01-01
Background Catheter-associated urinary tract infection (CAUTI) is a common nosocomial device-associated infection. It is now recognized that the high infection rates were caused by the formation of biofilm on the surface of the catheters that decreases the susceptibility to antibiotics and results in anti-microbial resistance. In this study, we performed an in vitro test to explore the mechanism of biofilm formation and subsequently conducted a multi-center clinical trial to investigate the efficacy of CAUTI prevention with the application of JUC, a nanotechnology antimicrobial spray. Methods Siliconized latex urinary catheters were cut into fragments and sterilized by autoclaving. The sterilized sample fragments were randomly divided into the therapy and control group, whereby they were sprayed with JUC and distilled water respectively and dried before use. The experimental standard strains of Escherichia coli (E. coli) were isolated from the urine samples of patients. At 16 hours and 7 days of incubation, the samples were extracted for confocal laser scanning microscopy. A total of 1,150 patients were accrued in the clinical study. Patients were randomized according to the order of surgical treatment. The odd array of patients was assigned as the therapy group (JUC), and the even array of patients was assigned as the control group (normal saline). Results After 16 hours of culture, bacterial biofilm formed on the surface of sample fragments from the control group. In the therapy group, no bacterial biofilm formation was observed on the sample fragments. No significant increase in bacterial colony count was observed in the therapy group after 7 days of incubation. On the 7th day of catheterization, urine samples were collected for bacterial culture before extubation. Significant difference was observed in the incidence of bacteriuria between the therapy group and control group (4.52% vs. 13.04%, p < 0.001). Conclusions In this study, the effectiveness of JUC in preventing CAUTI in a hospital setting was demonstrated in both in vitro and clinical studies. PMID:23046566
Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J
2015-04-22
Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.
The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis
Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio
2015-01-01
Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990
Beresford, Thomas; Buchanan, Jennifer; Thumm, Elizabeth Brie; Emrick, Chad; Weitzenkamp, David; Ronan, Patrick J
2017-12-01
Co-occurring schizophrenia spectrum disorder and International Statistical Classification of Diseases, 10th Revision cocaine dependence present a particularly destructive constellation that is often difficult to treat. Both conditions raise dopamine transmission effects in the brain. Traditional neuroleptics block dopamine receptors, whereas aripiprazole modulates dopamine activity as an agonist/antagonist. We tested whether dopamine modulation is superior to dopamine blocking in dual-diagnosis patients. In a randomized, double-blind, comparison design, cocaine-dependent schizophrenic subjects actively using cocaine received either aripiprazole or perphenazine in an 8-week trial. Primary outcome targeted cocaine-free urine sample proportions, whereas cocaine craving scores were a secondary variable. Subjects (N = 44) randomized (n = 22 per group) did not differ at baseline. The proportion of cocaine-free urine samples did not differ by medication group. Contrasting weeks 3 to 5 vs 6 to 8 revealed significant late reductions in craving with aripiprazole. On the respective 5-point subscales, craving intensity decreased by 1.53 ± 0.43 (P < 0.0005) points, craving frequency by 1.4 ± 0.40 (P > 0.0004) points, and craving duration by 1.76 ± 0.44 (P > 0.0001) points. A drug effect of aripiprazole on craving items appeared at week 6 of treatment, on average, and was not seen before that length of drug exposure. The data suggest that dopamine modulation reduces cocaine cravings but requires an acclimation period. To understand the mechanism of action better, a trial of depot aripiprazole may be useful. Clinically, a reduction in craving potentially offers a clearer focus for ongoing behavioral treatment. It may also offer a longer-term treatment effect with respect to the severity of relapse.
Middleton, Lisa S.; Wong, Conrad J.; Nuzzo, Paul A.; Campbell, Charles L.; Rush, Craig R.; Lofwall, Michelle R.
2016-01-01
Background Cocaine abuse continues to be a significant public health problem associated with morbidity and mortality. To date, no pharmacotherapeutic approach has proven effective for treating cocaine use disorders. Preclinical and clinical evidence suggests that noradrenergic activity may play a role in mediating some effects of cocaine and may be a rational target for treatment. Methods This double blind, placebo-controlled randomized, parallel group, 12-week outpatient clinical trial enrolled cocaine dependent individuals seeking treatment to examine the potential efficacy of the selective norepinephrine reuptake inhibitor, atomoxetine (80 mg/day; p.o.; n=25), compared to placebo (n=25). Subjects were initially stratified on cocaine use (<15 days or ≥15 days of the last 30), age and race using urn randomization. Attendance, medication adherence and study compliance were reinforced with contingency management, and weekly counseling was offered. An array of measures (vital signs, laboratory chemistries, cognitive and psychomotor tests, cocaine craving and urine samples for drug testing) was collected throughout the study and at follow-up. Results Survival analysis revealed no differences in study retention between the two groups, with approximately 56% of subjects completing the 12-week study (Cox analysis X2=.72; p=.40; Hazard Ratio 1.48 [CI 0.62–3.39]). GEE analysis of the proportion of urine samples positive for benzoylecgonine, a cocaine metabolite, revealed no differences between the atomoxetine and placebo groups (X2=0.2, p=.66; OR=0.89 [95% CI 0.41 – 1.74). Atomoxetine was generally well tolerated in this population. Conclusions These data provide no support for the utility of atomoxetine in the treatment of cocaine dependence. PMID:23200303
Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.
Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai
2015-01-01
The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.
Birgisdottir, B E; Knutsen, H K; Haugen, M; Gjelstad, I M; Jenssen, M T S; Ellingsen, D G; Thomassen, Y; Alexander, J; Meltzer, H M; Brantsæter, A L
2013-10-01
The first aim of the study was to evaluate calculated dietary intake and concentrations measured in blood or urine of essential and toxic elements in relation to nutritional and toxicological reference values. The second aim was to identify patterns of the element concentrations in blood and urine and to identify possible dietary determinants of the concentrations of these elements. Adults with a known high consumption of environmental contaminants (n=111), and a random sample of controls (n=76) answered a validated food frequency questionnaire (FFQ). Complete data on biological measures were available for 179 individuals. Blood and urine samples were analyzed for selenium, iodine, arsenic, mercury, cadmium and lead. Principal component analysis was used to identify underlying patterns of correlated blood and urine concentrations. The calculated intakes of selenium, iodine, inorganic arsenic and mercury were within guideline levels. For cadmium 24% of the high consumer group and 8% of the control group had intakes above the tolerable weekly intake. Concentrations of lead in blood exceeded the bench-mark dose lower confidence limits for some participants. However, overall, the examined exposures did not give rise to nutritional or toxicological concerns. Game consumption was associated with lead in blood (B(ln) 0.021; 95%CI:0.010, 0.031) and wine consumption. Seafood consumption was associated with urinary cadmium in non-smokers (B(ln) 0.009; 95%CI:0.003, 0.015). A novel finding was a distinct pattern of positively associated biological markers, comprising iodine, selenium, arsenic and mercury (eigenvalue 3.8), reflecting seafood intake (B 0.007; 95%CI:0.004, 0.010). The study clearly demonstrates the significance of seafood as a source of both essential nutrients and toxic elements simultaneously and shows that exposure to various essential and toxic elements can be intertwined. © 2013 Elsevier B.V. All rights reserved.
Simple DNA extraction of urine samples: Effects of storage temperature and storage time.
Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong
2018-06-01
Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.
Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D
2014-04-01
The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.
Aklin, Will M; Wong, Conrad J; Hampton, Jacqueline; Svikis, Dace S; Stitzer, Maxine L; Bigelow, George E; Silverman, Kenneth
2014-01-01
This study evaluated the long-term effects of a therapeutic workplace social business on drug abstinence and employment. Pregnant and postpartum women (N = 40) enrolled in methadone treatment were randomly assigned to a therapeutic workplace or usual care control group. Therapeutic workplace participants could work weekdays in training and then as employees of a social business, but were required to provide drug-free urine samples to work and maintain maximum pay. Three-year outcomes were reported previously. This paper reports 4- to 8-year outcomes. During year 4 when the business was open, therapeutic workplace participants provided significantly more cocaine- and opiate-negative urine samples than controls; reported more days employed, higher employment income, and less money spent on drugs. During the 3 years after the business closed, therapeutic workplace participants only reported higher income than controls. A therapeutic workplace social business can maintain long-term abstinence and employment, but additional intervention may be required to sustain effects. Copyright © 2014 Elsevier Inc. All rights reserved.
2014-01-01
This is the first quantitative analysis of data from urine drug tests for compliance to treatment medications and abstinence from drug abuse across “levels of care” in six eastern states of America. Comprehensive Analysis of Reported Drugs (CARD) data was used in this post-hoc retrospective observational study from 10,570 patients, filtered to include a total of 2,919 patients prescribed at least one treatment medication during 2010 and 2011. The first and last urine samples (5,838 specimens) were analyzed; compliance to treatment medications and abstinence from drugs of abuse supported treatment effectiveness for many. Compared to non-compliant patients, compliant patients were marginally less likely to abuse opioids, cannabinoids, and ethanol during treatment although more likely to abuse benzodiazepines. Almost 17% of the non-abstinent patients used benzodiazepines, 15% used opiates, and 10% used cocaine during treatment. Compliance was significantly higher in residential than in the non-residential treatment facilities. Independent of level of care, 67.2% of the patients (n = 1963; P<.001) had every treatment medication found in both first and last urine specimens (compliance). In addition, 39.2% of the patients (n = 1143; P<.001) had no substance of abuse detected in either the first or last urine samples (abstinence). Moreover, in 2010, 16.9% of the patients (n = 57) were abstinent at first but not at last urine (deteriorating abstinence), the percentage dropped to 13.3% (n = 174) in 2011; this improvement over years was statistically significant. A longitudinal analysis for abstinence and compliance was studied in a randomized subset from 2011, (n = 511) representing 17.5% of the total cohort. A statistically significant upward trend (p = 2.353×10−8) of abstinence rates as well as a similar but stronger trend for compliance ((p = 2.200×10−16) was found. Being cognizant of the trend toward drug urine testing being linked to medical necessity eliminating abusive screening, the interpretation of these valuable results require further intensive investigation. PMID:25247439
A magnetic bead-based method for concentrating DNA from human urine for downstream detection.
Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R
2013-01-01
Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.
A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection
Bordelon, Hali; Russ, Patricia K.; Wright, David W.; Haselton, Frederick R.
2013-01-01
Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×103 to 5×108 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×106, 14×106, and 8×106 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR. PMID:23861895
Does random urine drug testing reduce illicit drug use in chronic pain patients receiving opioids?
Manchikanti, Laxmaiah; Manchukonda, Rajeev; Pampati, Vidyasagar; Damron, Kim S; Brandon, Doris E; Cash, Kim A; McManus, Carla D
2006-04-01
Prescription drug abuse and illicit drug use are common in chronic pain patients. Adherence monitoring with screening tests, and urine drug testing, periodic monitoring with prescription monitoring programs, has become a common practice in recent years. Random drug testing for appropriate use of opioids and use of illicit drugs is often used in pain management practices. Thus, it is expected that random urine drug testing will deter use of illicit drugs, and also improve compliance. To study the prevalence of illicit drug use in patients receiving opioids for chronic pain management and to compare the results of illicit drug use with the results from a previous study. A prospective, consecutive study. Interventional pain management practice setting in the United States. A total of 500 consecutive patients on opioids, considered to be receiving stable doses of opioids supplemental to their interventional techniques, were studied by random drug testing. Testing was performed by rapid drug screen. Results were considered positive if one or more of the monitored illicit drugs including cocaine, marijuana (THC), methamphetamine or amphetamines were present. Illicit drug use was evident in 80 patients, or 16%, with marijuana in 11%, cocaine in 5%, and methamphetamine and/or amphetamines in 2%. When compared with previous data, the overall illicit drug use was significantly less. Illicit drug use in elderly patients was absent. The prevalence of illicit drug abuse in patients with chronic pain receiving opioids continues to be a common occurence. This study showed significant reductions in overall illicit drug use with adherence monitoring combined with random urine drug testing.
Jet Fuel Exposure and Neurological Health in Military Personnel
2011-07-01
and dermal samples E Absorbed Dose measure: Exhaled breath, urine , blood F Lifestyle factors (smoking), use of protective equipment (gloves...toluene, ethylbenzene, xylene, and naphthalene. To assess personal absorbed dose levels to JP8 components, exhaled breath and urine samples were...the following primary analytes of interest were measured: benzene, toluene, ethylbenzene, xylene, and naphthalene. Pre- and post- shift urine samples
NASA Technical Reports Server (NTRS)
Bush, V. N.
1973-01-01
A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.
Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.
Shelver, Weilin L; Smith, David J
2018-06-06
Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g -1 or mL -1 across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution; skeletal muscle required solvent extraction prior to testing. Of 32 incurred sheep urine samples tested, zilpaterol content was correctly identified in all but 2 samples. Horse urine containing >10 ng mL -1 of incurred zilpaterol residue (n = 48) was correctly identified as zilpaterol positive. The assay correctly identified 0-day withdrawal sheep muscle samples as zilpaterol positive and the control and longer withdrawal day sheep muscle samples as negative. Zilpaterol was demonstrated to be stable in horse urine when stored at -20°C for 7 years.
Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H
2014-06-10
Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.
Ramsay, Edward; Sadler, Ryan; Rush, Robert; Seimon, Tracie; Tomaszewicz, Ania; Fleetwood, Ellen A; McAloose, Denise; Wilkes, Rebecca P
2016-06-01
Three methods for delivering a live attenuated canine distemper virus (CDV) vaccine to domestic cats ( Felis catus ) were investigated, as models for developing vaccination protocols for tigers (Panthera tigris). Twenty domestic cats were randomly divided into four treatment groups: saline injection (negative controls); and oral, intranasal, and subcutaneous vaccinates. Cats were injected with saline or a CDV vaccine (Nobivac DP, Merck) at wk 0 and 4. Blood and nasal swabs were collected at wk 0 (prior to the initial vaccination) and weekly thereafter for 9 wk. Urine samples were collected on wk 1 to 9 after initial vaccination. Forty-nine weeks following the initial vaccination series, three cats from the subcutaneous group and three cats from the intranasal group were revaccinated. Blood was collected immediately prior, and 7 and 21 days subsequent to revaccination. Nasal swabs and urine samples were collected from each cat prior to wk 49 revaccination and daily for 7 days thereafter. Nasal swabs and urine were analyzed by quantitative PCR for vaccine virus presence. Sera were tested for CDV antibodies by virus neutralization. All cats were sero-negative for CDV antibodies at the beginning of the study, and saline-injected cats remained sero-negative throughout the study. A dramatic anamnestic response was seen following wk 4 subcutaneous vaccinations, with titers peaking at wk 6 (geometric mean = 2,435.5). Following wk 49 revaccination, subcutaneous vaccinates again mounted impressive titers (wk 52 geometric mean = 2,048). Revaccination of the intranasal group cats at wk 49 produced a small increase in titers (wk 52 geometric mean = 203). CDV viral RNA was detected in six nasal swabs but no urine samples, demonstrating low viral shedding postvaccination. The strong antibody response to subcutaneous vaccination and the lack of adverse effects suggest this vaccine is safe and potentially protective against CDV infection in domestic cats.
USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES
Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...
The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative
NASA Technical Reports Server (NTRS)
Nillen, Jeannie L.; Smith, Scott M.
2003-01-01
A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.
Lepedda, Antonio Junior; Nieddu, Gabriele; Rocchiccioli, Silvia; Fresu, Pietro; De Muro, Pierina; Formato, Marilena
2013-12-01
Bikunin is a plasma proteinase inhibitor often associated with inflammatory conditions. It has a half-life of few minutes and it is rapidly excreted into urine as urinary trypsin inhibitor (UTI). UTI levels are usually low in healthy individuals but they can increase up to tenfold in both acute and chronic inflammatory diseases. This article describes a sensitive method for both direct UTI quantitation and structural characterization. UTI purification was performed by anion exchange micro-chromatography followed by SDS-PAGE. A calibration curve for protein quantitation was set up by using a purified UTI fraction. UTI identification and structural characterization was performed by Nano-LC-MS/MS analysis. The method was applied on urine samples from 9 patients with type 1 diabetes, 11 patients with type 2 diabetes, and 28 healthy controls, matched for age and sex with patients, evidencing higher UTI levels in both groups of patients with respect to controls (p < 0.001 and p = 0.001, respectively). Spearman's correlation tests highlighted no association between UTI levels and age in each group tested. Owing to the elevated sensitivity and specificity, the described method allows UTI quantitation from very low quantities of specimen. Furthermore, as UTI concentration is normalized for creatinine level, the analysis could be also performed on randomly collected urine samples. Finally, MS/MS analysis prospects the possibility of characterizing PTM sites potentially able to affect UTI localization, function, and pathophysiological activity. Preliminary results suggest that UTI levels could represent a useful marker of chronic inflammatory condition in type 1 and 2 diabetes. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rosinger, Asher
2015-12-01
Hydration status is critical to physiological and cognitive health, yet it is unclear how populations living in hot-humid environments experiencing lifestyle transitions manage this underexplored facet of heat adaptation. This study assesses the predictors of repeated measures of hydration status for adults from two villages (close and distant from a market town) in the Bolivian Amazon. Interviews and focal follows were conducted with 36 Tsimane' (50% male). Urine samples, temperature, activity levels, and anthropometrics were measured pre-interview and post-follow and yielded a small panel (72 observations). Urine samples were analyzed for urine specific gravity (USG), a biomarker of hydration, with a refractometer. The mean USG was 1.020 g/ml (SD ± 0.008) with men (1.022 ± 0.008) slightly more dehydrated than women (1.018 ± 0.007). Using 1.020 as the criteria for clinical dehydration, 42% of the participants were dehydrated at both intervals and 21% were extremely dehydrated. Controlling for activity level, village membership, and covariates in random-effects linear regression models, each degree centigrade increase was associated with a USG increase of 0.0008 g/ml (P = 0.000). Adults from the village closer to the market town had significantly higher USG (B = 0.0041; P = 0.04) than those in the distant village. Dehydration was predicted to occur at 29°C, just above the thermoneutral range, and extreme dehydration at 37°C. These findings suggest that hotter temperatures coupled with lifestyle transitions may create conditions that increase vulnerability to dehydration among rural populations through landscape modifications and diet changes. © 2015 Wiley Periodicals, Inc.
Ferreira, Fernanda Teixeira; Fidelis, Thiago André; Pereira, Thiago Almeida; Otoni, Alba; Queiroz, Leonardo Campos; Amâncio, Frederico Figueiredo; Antunes, Carlos Maurício; Lambertucci, José Roberto
2017-01-01
The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis. The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%). Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.
Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...
24-hour urinary aldosterone excretion test
Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...
Temporal variability of urinary cadmium in spot urine samples and first morning voids.
Vacchi-Suzzi, Caterina; Porucznik, Christina A; Cox, Kyley J; Zhao, Yuan; Ahn, Hongshik; Harrington, James M; Levine, Keith E; Demple, Bruce; Marsit, Carmen J; Gonzalez, Adam; Luft, Benjamin; Meliker, Jaymie R
2017-05-01
Cadmium is a carcinogenic heavy metal. Urinary levels of cadmium are considered to be an indicator of long-term body burden, as cadmium accumulates in the kidneys and has a half-life of at least 10 years. However, the temporal stability of the biomarker in urine samples from a non-occupationally exposed population has not been rigorously established. We used repeated measurements of urinary cadmium (U-Cd) in spot urine samples and first morning voids from two separate cohorts, to assess the temporal stability of the samples. Urine samples from two cohorts including individuals of both sexes were measured for cadmium and creatinine. The first cohort (Home Observation of Perinatal Exposure (HOPE)) consisted of 21 never-smokers, who provided four first morning urine samples 2-5 days apart, and one additional sample roughly 1 month later. The second cohort (World Trade Center-Health Program (WTC-HP)) consisted of 78 individuals, including 52 never-smokers, 22 former smokers and 4 current smokers, who provided 2 spot urine samples 6 months apart, on average. Intra-class correlation was computed for groups of replicates from each individual to assess temporal variability. The median creatinine-adjusted U-Cd level (0.19 and 0.21 μg/g in the HOPE and WTC-HP, respectively) was similar to levels recorded in the United States by the National Health and Nutrition Examination Survey. The intra-class correlation (ICC) was high (0.76 and 0.78 for HOPE and WTC-HP, respectively) and similar between cohorts, irrespective of whether samples were collected days or months apart. Both single spot or first morning urine cadmium samples show good to excellent reproducibility in low-exposure populations.
Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J
2016-06-01
The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.
Faraji, Hakim; Helalizadeh, Masoumeh
2017-04-01
Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.
Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds
Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz
2017-01-01
The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329
Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning
2013-03-01
Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ix, Joachim H; Katz, Ronit; Bansal, Nisha; Foster, Meredith; Weiner, Daniel E; Tracy, Russell; Jotwani, Vasantha; Hughes-Austin, Jan; McKay, Dianne; Gabbai, Francis; Hsu, Chi-Yuan; Bostom, Andrew; Levey, Andrew S; Shlipak, Michael G
2017-03-01
Kidney tubulointerstitial fibrosis marks risk for allograft failure in kidney transplant recipients, but is poorly captured by estimated glomerular filtration rate (eGFR) or urine albumin-creatinine ratio (ACR). Whether urinary markers of tubulointerstitial fibrosis can noninvasively identify risk for allograft failure above and beyond eGFR and ACR is unknown. Case-cohort study. The FAVORIT (Folic Acid for Vascular Outcome Reduction in Transplantation) Trial was a randomized double-blind trial testing vitamin therapy to lower homocysteine levels in stable kidney transplant recipients. We selected a subset of participants at random (n=491) and all individuals with allograft failure during follow-up (cases; n=257). Using spot urine specimens from the baseline visit, we measured 4 urinary proteins known to correlate with tubulointerstitial fibrosis on biopsy (urine α 1 -microglobulin [A1M], monocyte chemoattractant protein 1 [MCP-1], and procollagen type III and type I amino-terminal amino pro-peptide). Death-censored allograft failure. In models adjusted for demographics, chronic kidney disease risk factors, eGFR, and ACR, higher concentrations of urine A1M (HR per doubling, 1.73; 95% CI, 1.43-2.08) and MCP-1 (HR per doubling, 1.60; 95% CI, 1.32-1.93) were strongly associated with allograft failure. When additionally adjusted for concentrations of other urine fibrosis and several urine injury markers, urine A1M (HR per doubling, 1.76; 95% CI, 1.27-2.44]) and MCP-1 levels (HR per doubling, 1.49; 95% CI, 1.17-1.89) remained associated with allograft failure. Urine procollagen type III and type I levels were not associated with allograft failure. We lack kidney biopsy data, BK titers, and HLA antibody status. Urine measurement of tubulointerstitial fibrosis may provide a noninvasive method to identify kidney transplant recipients at higher risk for future allograft failure, above and beyond eGFR and urine ACR. Published by Elsevier Inc.
Charlton, Karen; Menyanu, Elias; Biritwum, Richard Berko; Naidoo, Nirmala; Pieterse, Chiné; Madurai, Savathree (Lorna); Baumgartner, Jeannine; Asare, George A; Thiele, Elizabeth; Schutte, Aletta E; Kowal, Paul
2016-01-01
Introduction Attempting to curb the rising epidemic of hypertension, South Africa implemented legislation in June 2016 mandating maximum sodium levels in a range of manufactured foods that contribute significantly to population salt intake. This natural experiment, comparing two African countries with and without salt legislation, will provide timely information on the impact of legislative approaches addressing the food supply to improve blood pressure in African populations. This article outlines the design of this ongoing prospective nested cohort study. Methods and analysis Baseline sodium intake was assessed in a nested cohort of the WHO Study on global AGEing and adult health (WHO-SAGE) wave 2 (2014–2015), a multinational longitudinal study on the health and well-being of adults and the ageing process. The South African cohort consisted of randomly selected households (n=4030) across the country. Spot and 24-hour urine samples are collected in a random subsample (n=1200) and sodium, potassium, creatinine and iodine analysed. Salt behaviour and sociodemographic data are captured using face-to-face interviews, alongside blood pressure and anthropometric measures. Ghana, the selected control country with no formal salt policy, provided a nested subsample (n=1200) contributing spot and 24-hour urine samples from the SAGE Ghana cohort (n=5000). Follow-up interviews and urine collection (wave 3) in both countries will take place in 2017 (postlegislation) to assess change in population-level sodium intake and blood pressure. Ethics and dissemination SAGE was approved by the WHO Ethics Review Committee (reference number RPC149) with local approval from the North-West University Human Research Ethics Committee and University of the Witwatersrand Human Research Ethics Committee (South Africa), and University of Ghana Medical School Ethics and Protocol Review Committee (Ghana). The results of the study will be published in peer-reviewed international journals, presented at national and international conferences, and summarised as research and policy briefs. PMID:27903563
Erickson, D.A.; Gingerich, W.H.
1986-01-01
Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.
NHEXAS PHASE I MARYLAND STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 9 pesticides in 345 urine samples over 79 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning ...
NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...
Coorevits, L; Heytens, S; Boelens, J; Claeys, G
2017-04-01
The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3 colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4 CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.
Wilhelm, M; Ohnesorge, F K
1990-01-01
The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.
Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo
2014-01-01
Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.
Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo
2014-01-01
Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168
Tracer techniques for urine volume determination and urine collection and sampling back-up system
NASA Technical Reports Server (NTRS)
Ramirez, R. V.
1971-01-01
The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.
Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M
2009-09-01
Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.
Occupational hazards and safety measures amongst the paint factory workers in lagos, Nigeria.
Awodele, Olufunsho; Popoola, Temidayo D; Ogbudu, Bawo S; Akinyede, Akin; Coker, Herbert A B; Akintonwa, Alade
2014-06-01
The manufacture of paint involves a variety of processes that present with medical hazards. Safety initiatives are hence introduced to limit hazard exposures and promote workplace safety. This aim of this study is to assess the use of available control measures/initiatives in selected paint factories in Lagos West Senatorial District, Nigeria. A total of 400 randomly selected paint factory workers were involved in the study. A well-structured World Health Organization standard questionnaire was designed and distributed to the workers to elicit information on awareness to occupational hazards, use of personal protective devices, and commonly experienced adverse symptoms. Urine samples were obtained from 50 workers randomly selected from these 400 participants, and the concentrations of the heavy metals (lead, cadmium, arsenic, and chromium) were determined using atomic absorption spectroscopy. The results show that 72.5% of the respondents are aware of the hazards associated with their jobs; 30% have had formal training on hazards and safety measures; 40% do not use personal protective devices, and 90% of the respondents reported symptoms relating to hazard exposure. There was a statistically significant (p < 0.05) increase in the mean heavy metal concentrations in the urine samples obtained from paint factory workers as compared with nonfactory workers. The need to develop effective frameworks that will initiate the integration and ensure implementation of safety regulations in paint factories is evident. Where these exist, there is a need to promote adherence to these practice guidelines.
Urinalysis in children and adolescents.
Utsch, Boris; Klaus, Günter
2014-09-12
Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.
Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W
2013-12-01
To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.
Osada, Kazumi; Kurihara, Kenzo; Izumi, Hiroshi; Kashiwayanagi, Makoto
2013-01-01
Background The common grey wolf (Canis lupus) is found throughout the entire Northern hemisphere and preys on many kinds of mammals. The urine of the wolf contains a number of volatile constituents that can potentially be used for predator–prey chemosignalling. Although wolf urine is put to practical use to keep rabbits, rodents, deer and so on at bay, we are unaware of any prior behavioural studies or chemical analyses regarding the fear-inducing impact of wolf urine on laboratory mice. Methodology/Principal Findings Three wolf urine samples harvested at different times were used in this study. All of them induced stereotypical fear-associated behaviors (i.e., avoidance and freezing) in female mice. The levels of certain urinary volatiles varied widely among the samples. To identify the volatiles that provoked avoidance and freezing, behavioural, chemical, and immunohistochemical analyses were performed. One of the urine samples (sample C) had higher levels of 2,6-dimethylpyrazine (DMP), trimethylpyrazine (TMP), and 3-ethyl-2,5-dimethyl pyrazine (EDMP) compared with the other two urine samples (samples A and B). In addition, sample C induced avoidance and freezing behaviours more effectively than samples A and B. Moreover, only sample C led to pronounced expression of Fos-immunoreactive cells in the accessory olfactory bulb (AOB) of female mice. Freezing behaviour and Fos immunoreactivity were markedly enhanced when the mice were confronted with a mixture of purified DMP, TMP, and EDMP vs. any one pyrazine alone. Conclusions/Significance The current results suggest that wolf urinary volatiles can engender aversive and fear-related responses in mice. Pyrazine analogues were identified as the predominant active components among these volatiles to induce avoidance and freezing behaviours via stimulation of the murine AOB. PMID:23637901
Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G
2004-08-01
European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.
NHEXAS PHASE I MARYLAND STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 3 metals in 376 urine samples over 80 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning void of either Day ...
Mirtazapine to Reduce Methamphetamine Use
Colfax, Grant N.; Santos, Glenn-Milo; Das, Moupali; Santos, Deirdre McDermott; Matheson, Tim; Gasper, James; Shoptaw, Steve; Vittinghoff, Eric
2012-01-01
Context No approved pharmacologic treatments for methamphetamine dependence exist. Methamphetamine use is associated with high morbidity and is a major cofactor in the human immunodeficiency virus epidemic among men who have sex with men (MSM). Objective To determine whether mirtazapine would reduce methamphetamine use among MSM who are actively using methamphetamine. Design Double-blind, randomized, controlled, 12-week trial of mirtazapine vs placebo conducted from September 5, 2007, to March 4, 2010. Setting San Francisco Department of Public Health. Participants Participants were actively using, methamphetamine-dependent, sexually active MSM seen weekly for urine sample collection and substance use counseling. Interventions Random assignment to daily oral mirtazapine (30 mg) or placebo; both arms included 30-minute weekly substance use counseling. Main Outcome Measures The primary study outcome was reduction in methamphetamine-positive urine test results. Secondary outcomes were study medication adherence (by self-report and medication event monitoring systems) and sexual risk behavior. Results Sixty MSM were randomized, 85% of follow-up visits were completed, and 56 participants (93%) completed the final visit. In the primary intent-to-treat analysis, participants assigned to the mirtazapine group had fewer methamphetamine-positive urine test results compared with participants assigned to the placebo group (relative risk, 0.57; 95% CI, 0.35–0.93, P = .02). Urine positivity decreased from 67% (20 of 30 participants) to 63% (17 of 27) in the placebo arm and from 73% (22 of 30) to 44% (12 of 27) in the mirtazapine arm. The number needed to treat to achieve a negative weekly urine test result was 3.1. Adherence was 48.5% by medication event monitoring systems and 74.7% by self-report; adherence measures were not significantly different between arms (medication event monitoring systems, P = .82; self-report, P = .92). Most sexual risk behaviors decreased significantly more among participants taking mirtazapine compared with those taking placebo (number of male partners with whom methamphetamine was used, P = .009; number of male partners, P = .04; episodes of anal sex with serodiscordant partners, P = .003; episodes of unprotected anal sex with serodiscordant partners, P = .003; episodes of insertive anal sex with serodiscordant partners, P = .001). There were no serious adverse events related to study drug or significant differences in adverse events by arm (P ≥ .99). Conclusion The addition of mirtazapine to substance use counseling decreased methamphetamine use among active users and was associated with decreases in sexual risk despite low to moderate medication adherence. PMID:22065532
Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples
Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely
2008-01-01
Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170
Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan
2012-01-01
Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718
Skalisky, Jordan; Leickly, Emily; Oluwoye, Oladunni; McPherson, Sterling M; Srebnik, Debra; Roll, John M; Ries, Richard K; McDonell, Michael G
2017-01-01
Introduction: People with serious mental illness (SMI) use cannabis more than any other illicit drug. Cannabis use is associated with increased psychotic symptoms and is highly comorbid with alcohol use disorders (AUDs). Despite the national trend toward decriminalization, little is known about the prevalence, correlates, and impact of cannabis use on those with SMI receiving treatment for substance use disorders, a group at high risk for the negative effects of cannabis use. Methods: In this secondary data analysis, cannabis use prevalence, correlates, and impact on treatment outcomes were examined in 121 adults with cooccurring SMI and AUDs receiving outpatient addiction treatment in a randomized trial of contingency management (CM) for alcohol. Prevalence and frequency of cannabis use were calculated across the 7-month study period using self-report and urine tests. Cannabis users were compared with nonusers by SMI diagnosis, psychiatric symptoms, medical problems, legal problems, and HIV-risk behavior. The relationship between cannabis use and longest duration of alcohol abstinence in participants randomized to CM ( n =40) was assessed. Results: Fifty-seven (47%) of participants submitted at least one cannabis-positive urine sample during the study. Out of the 2834 total samples submitted, 751 (27%) were positive for cannabis. Cannabis users were 2.2 times more likely to submit an alcohol-positive sample, and 2.5 times more likely to submit a cocaine-positive sample at baseline, relative to noncannabis users ( p =0.01). Cannabis users were more likely to engage in risky sexual behavior ( p =0.01) and to report being homeless ( p =0.03) than nonusers. When controlling for pretreatment alcohol use, the relationship between comorbid cannabis use and alcohol abstinence during CM was not significant ( p =0.77). Conclusion: Rates of comorbid cannabis use were high in this sample of adults with SMI and AUDs. Cannabis use was correlated with recent alcohol and cocaine use, risky sexual behavior, and homelessness, but not with alcohol abstinence during CM.
Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan
2017-12-15
A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSD<3.1%, n=6) and good linearity in the range of 50-1000mgL -1 and 0.5-100mgL -1 , respectively. By this method, concentrations of GHB in the selected human urine samples were detected in the range of 0-1.57mgL -1 . The urine sample containing 0.89mgL -1 GHB was selected to evaluate the accuracy; the spiked recoveries of GHB were 95.9-102.8%. The results showed that the two-dimensional ion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Development of Technologies for Early Detection and Stratification of Breast Cancer
2014-10-01
cancer. Similar screening has been done in urine samples with CYR61 and LCN2 (Figure 2a-b). The Moses lab provided breast cancer urine samples and two ...diseased samples, while CYR61 appears to have two different populations whereas diseased urine samples have lower levels of the protein present. More... system for eDAR so that each isolated cell can be deposited into a well of a 96-well plate for high-throughput downstream single-cell digital
Olesti, Eulàlia; Pujadas, Mitona; Papaseit, Esther; Pérez-Mañá, Clara; Pozo, Óscar J; Farré, Magí; de la Torre, Rafael
2017-03-01
Increasing consumption has been observed among young people of new psychoactive substances, including synthetic cathinone derivatives. The most well known of these is mephedrone whose use has been related to acute intoxication and fatality. Several methods able to detect mephedrone have been reported, although to date, none have been applied to human pharmacokinetic studies in a controlled setting. We developed a gas chromatography-mass spectrometry technique for mephedrone quantification in human plasma and urine. Plasma after deproteinization and urine were submitted to a liquid-liquid extraction and derivatization of the extract with MSTFA prior to analysis. Calibration curves covered concentration ranges in plasma between 5 and 300 ng/mL and in urine between 20 and 1,500 ng/mL. The method has been successfully applied to biological samples obtained from a pilot clinical trial intended to evaluate the human pharmacology of mephedrone and its relative bioavailability and pharmacokinetics. Six healthy males were administered 150 mg of mephedrone by the oral route in a randomized, double-blind, cross-over controlled trial. Peak plasma concentration (Cmax = 122.6 ± 32.9 ng/mL) was reached at 1 hour (0.5-2 h) post-drug administration. Mephedrone showed a rapid elimination half-life (t1/2 = 2.2 h) compared to other psychostimulants. Less than 15% of the dose was excreted in urine as a free-form. Mephedrone concentrations displayed a relevant inter-subject variability. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto
2017-08-01
When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Immunoreactive LH in long-term frozen human urine samples.
Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J
2014-04-01
Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.
Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan
2016-06-05
In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.
Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O
1996-01-01
This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.
Initial abstinence status and contingency management treatment outcomes: does race matter?
Montgomery, LaTrice; Carroll, Kathleen M; Petry, Nancy M
2015-06-01
Limited research has evaluated African American substance users' response to evidence-based treatments. This study examined the efficacy of contingency management (CM) in African American and White cocaine users. A secondary analysis evaluated effects of race, treatment condition, and baseline cocaine urine sample results on treatment outcomes of African American (n = 444) and White (n = 403) cocaine abusers participating in one of six randomized clinical trials comparing CM to standard care. African American and White patients who initiated treatment with a cocaine-negative urine sample remained in treatment for similar durations and submitted a comparable proportion of negative samples during treatment regardless of treatment type; CM was efficacious in both races in terms of engendering longer durations of abstinence in patients who began treatment abstinent. Whites who began treatment with a cocaine positive sample remained in treatment longer and submitted a higher proportion of negative samples when assigned to CM than standard care. African Americans who initiated treatment with a cocaine positive sample, however, did not remain in treatment longer with CM compared with standard care, and gains in terms of drug use outcomes were muted in nature relative to Whites. This interaction effect persisted through the 9-month follow-up period. CM is not equally effective in reducing drug use among all subgroups, specifically African American patients who are using cocaine upon treatment entry. Future research on improving treatment outcomes in this population is needed. (c) 2015 APA, all rights reserved).
Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe
2007-01-01
Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitablemore » sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.« less
Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L
2017-08-22
The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.
Diagnosis and effects of urine contamination in cooled-extended stallion semen.
Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K
2016-04-15
Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65%) and high specificity (100%), while color assessment presented low sensitivity (47%) and moderate specificity (79%) for urine in extended semen. Azostix strips were highly sensitive (95%) and specific (97%). Assessment of color, odor, and pH are not reliable methods to diagnose urine in experimentally contaminated cooled-stored stallion semen. Sperm motility parameters (in raw and cooled semen) are significantly reduced by the presence of urine in a concentration dependent. The results of the present study indicated that determination of urea and creatinine concentrations can be used to diagnose urospermia and that Azostix can be used as a point care method for diagnosing urine contamination in extended cooled stallion semen. Copyright © 2016 Elsevier Inc. All rights reserved.
Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi
2005-01-01
We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.
Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.
Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R
1994-12-01
LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.
Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H
2014-02-01
A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.
Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine.
Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim
2015-01-01
Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable.
Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine
Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim
2015-01-01
Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable. PMID:26208298
Kitagawa, Koichi; Shigemura, Katsumi; Onuma, Ken-Ichiro; Nishida, Masako; Fujiwara, Mayu; Kobayashi, Saori; Yamasaki, Mika; Nakamura, Tatsuya; Yamamichi, Fukashi; Shirakawa, Toshiro; Tokimatsu, Issei; Fujisawa, Masato
2018-03-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) contributes to rapid identification of pathogens in the clinic but has not yet performed especially well for Gram-positive cocci (GPC) causing complicated urinary tract infection (UTI). The goal of this study was to investigate the possible clinical use of MALDI-TOF MS as a rapid method for bacterial identification directly from urine in complicated UTI. MALDI-TOF MS was applied to urine samples gathered from 142 suspected complicated UTI patients in 2015-2017. We modified the standard procedure (Method 1) for sample preparation by adding an initial 10 minutes of ultrasonication followed by centrifugation at 500 g for 1 minutes to remove debris such as epithelial cells and leukocytes from the urine (Method 2). In 133 urine culture-positive bacteria, the rate of corresponded with urine culture in GPC by MALDI-TOF MS in urine with standard sample preparation (Method 1) was 16.7%, but the modified sample preparation (Method 2) significantly improved that rate to 52.2% (P=.045). Method 2 also improved the identification accuracy for Gram-negative rods (GNR) from 77.1% to 94.2% (P=.022). The modified Method 2 significantly improved the average MALDI score from 1.408±0.153 to 2.166±0.045 (P=.000) for GPC and slightly improved the score from 2.107±0.061 to 2.164±0.037 for GNR. The modified sample preparation for MALDI-TOF MS can improve identification accuracy for complicated UTI causative bacteria. This simple modification offers a rapid and accurate routine diagnosis for UTI, and may possibly be a substitute for urine cultures. © 2017 Wiley Periodicals, Inc.
Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.
Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M
2017-09-01
Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Fizazi, Karim; Bosserman, Linda; Gao, Guozhi; Skacel, Tomas; Markus, Richard
2013-01-01
Patients with bone metastases have high rates of RANKL driven bone resorption and an increased risk of skeletal morbidity. Osteoclast mediated bone resorption can be assessed by measuring urine N-telopeptide and can be inhibited by denosumab, a fully human antibody against RANKL. Eligible patients (111) had bone metastases from prostate cancer, other solid tumors or multiple myeloma, 1 or more bone lesions and urine N-telopeptide greater than 50 nM bone collagen equivalents per mM creatinine (urine N-telopeptide greater than 50) despite the use of intravenous bisphosphonates. Patients were stratified by cancer type and screening urine N-telopeptide, and randomized to continue intravenous bisphosphonates every 4 weeks or receive 180 mg subcutaneous denosumab every 4 weeks or 180 mg every 12 weeks. The primary end point was the proportion of patients with urine N-telopeptide less than 50 at week 13. We report the efficacy results for the subset of patients with prostate cancer. Patients with prostate cancer represented 45% (50 of 111) of the study population. At week 13, 22 of 32 (69%) patients in the denosumab arms had urine N-telopeptide less than 50 vs 3 of 16 (19%) in the intravenous bisphosphonates cohort. At week 25, 22 of 32 (69%) denosumab treated patients continued to have urine N-telopeptide less than 50 vs 5 of 16 (31%) treated with intravenous bisphosphonates. Grade 4, asymptomatic, reversible hypophosphatemia, possibly related to denosumab, was reported in 1 patient. In patients with prostate cancer related bone metastases and increased urine N-telopeptide despite intravenous bisphosphonate treatment, denosumab normalized urine N-telopeptide levels more frequently than ongoing intravenous bisphosphonates. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Automated biowaste sampling system urine subsystem operating model, part 1
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Mangialardi, J. K.; Rosen, F.
1973-01-01
The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.
Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael
2005-07-01
In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.
Chen, Guixia; Chen, Xiaoxin; Yan, Chonghuai; Wu, Xingdong; Zeng, Guozhang
2014-01-01
Aim: The average mercury load in children under 7-years old was determined in a populated but not overly industrial coastal area in China. Methods: 395 blood samples, 1072 urine samples, and 581 hair samples were collected from 1076 children, aged 0 to 6 years, from eight representative communities of Xiamen, China. Mercury levels in the samples were surveyed. Results: The 95% upper limits of mercury in blood, urine, and hair for the children were 2.30, 1.50 and 2100.00 μg/kg, respectively. Levels tended to increase with age. Correlation analyses showed that mercury levels in blood and urine correlated with those in hair (n = 132), r = 0.49, p < 0.0001 and r = 0.20, p = 0.0008; however, blood mercury levels did not correlate with urine levels (n = 284), r = 0.07, p = 0.35. Conclusions: Surveying the average mercury load in children 0 to 6 years, and the 95% upper limit value of mercury in their blood, urine, and hair should help guide risk assessment and health management for children. PMID:25419876
Major Odorants Released as Urinary Volatiles by Urinary Incontinent Patients
Pandey, Sudhir Kumar; Kim, Ki-Hyun; Choi, Si On; Sa, In Young; Oh, Soo Yeon
2013-01-01
In this study, volatile urinary components were collected using three different types of samples from patients suffering from urinary incontinence (UI): (1) urine (A); (2) urine + non-used pad (B); and (3) urine + used pad (C). In addition, urine + non-used pad (D) samples from non-patients were also collected as a reference. The collection of urinary volatiles was conducted with the aid of a glass impinger-based mini-chamber method. Each of the four sample types (A through D) was placed in a glass impinger and incubated for 4 hours at 37 °C. Ultra pure air was then passed through the chamber, and volatile urine gas components were collected into Tedlar bags at the other end. These bag samples were then analyzed for a wide range of VOCs and major offensive odorants (e.g., reduced sulfur compounds (RSCs), carbonyls, trimethylamine (TMA), ammonia, etc.). Among the various odorants, sulfur compounds (methanethiol and hydrogen sulfide) and aldehydes (acetaldehyde, butylaldehyde, and isovaleraldehyde) were detected above odor threshold and predicted to contribute most effectively to odor intensity of urine incontinence. PMID:23823973
Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew
2007-01-01
The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.
NASA Technical Reports Server (NTRS)
Wingard, C. D.
2015-01-01
On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.
Flow meter urine testing: a practical proposition in patients attending for urodynamics?
Hashim, Hashim; Abrams, Paul
2006-05-01
To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.
Reproducibility of urinary biomarkers in multiple 24-h urine samples.
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.
Reproducibility of urinary biomarkers in multiple 24-h urine samples123
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663
Marques, Cláudia; Fernandes, Iva; Norberto, Sónia; Sá, Carla; Teixeira, Diana; de Freitas, Victor; Mateus, Nuno; Calhau, Conceição; Faria, Ana
2016-11-01
This study was designed to evaluate the influence of ethanol on the bioavailability of blackberry anthocyanins. A total of 18 participants were recruited to consume 250 mL of a blackberry puree (650 mg of anthocyanins) without (BBP) or with 12% ethanol (BBP 12%). Venous blood was collected from participants at baseline and at 15, 30, 60, and 120 min after puree ingestion. Urine samples were collected at baseline and at 120 min. Plasma and urine concentration of anthocyanins and anthocyanin conjugates were quantified by HPLC-DAD. Methyl-cyanidin-glucuronide (Me-Cy-Glucr) and 3'-methyl-cyanidin-3-glucoside (3'-Me-Cy3glc) were the main anthocyanin conjugates detected in all plasma and urine samples. Urinary concentration of these anthocyanin conjugates were positively correlated with their plasma concentration. Ethanol increased plasma C max of Me-Cy-Glucr and 3'-Me-Cy3glc. Participants were then stratified according to their body mass index (BMI) and body fat mass. After BBP consumption, plasma C max of Me-Cy-Glucr and 3'-Me-Cy3glc tended to be decreased in overweight/obese participants, in comparison to normal weight participants. The increase on plasma C max of Me-Cy-Glucr and 3'-Me-Cy3glc induced by ethanol was more pronounced in the group of overweight/obese participants. Ethanol seems to enhance Cy3glc metabolism that appears to be compromised in overweight and obese individuals. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Berg, Wolfgang; Bechler, Robin; Laube, Norbert
2009-01-01
Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.
Mining the human urine proteome for monitoring renal transplant injury
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Gao, Yuqian; He, Jintang
The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used inmore » the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.« less
Acute Consumption of Flavan-3-ol-Enriched Dark Chocolate Affects Human Endogenous Metabolism.
Ostertag, Luisa M; Philo, Mark; Colquhoun, Ian J; Tapp, Henri S; Saha, Shikha; Duthie, Garry G; Kemsley, E Kate; de Roos, Baukje; Kroon, Paul A; Le Gall, Gwénaëlle
2017-07-07
Flavan-3-ols and methylxanthines have potential beneficial effects on human health including reducing cardiovascular risk. We performed a randomized controlled crossover intervention trial to assess the acute effects of consumption of flavan-3-ol-enriched dark chocolate, compared with standard dark chocolate and white chocolate, on the human metabolome. We assessed the metabolome in urine and blood plasma samples collected before and at 2 and 6 h after consumption of chocolates in 42 healthy volunteers using a nontargeted metabolomics approach. Plasma samples were assessed and showed differentiation between time points with no further separation among the three chocolate treatments. Multivariate statistics applied to urine samples could readily separate the postprandial time points and distinguish between the treatments. Most of the markers responsible for the multivariate discrimination between the chocolates were of dietary origin. Interestingly, small but significant level changes were also observed for a subset of endogenous metabolites. 1 H NMR revealed that flavan-3-ol-enriched dark chocolate and standard dark chocolate reduced urinary levels of creatinine, lactate, some amino acids, and related degradation products and increased the levels of pyruvate and 4-hydroxyphenylacetate, a phenolic compound of bacterial origin. This study demonstrates that an acute chocolate intervention can significantly affect human metabolism.
Rennie, Robert P; Turnbull, Lee-Ann; Gauchier-Pitts, Kaylee; Bennett, Tracy; Dyrland, Debbie; Blonski, Susan
2016-08-01
The ability to isolate and identify causative agents of urinary tract infections relies primarily on the quality of the urine sample that is submitted to the microbiology. The most important factors are the method of collection, the maintenance of viability of the potential pathogens during transport, and standardization of the culturing of the urine sample. This report is a composite of several investigations comparing collection and transport on urine culture paddles, with a preservative urine sponge (Uriswab), and a comparison of Uriswab with the BD preservative transport tube as methods of preservation of urinary pathogens. Primary studies showed that Uriswab maintained significantly more urinary pathogens than the urine culture paddle with fewer mixed or contaminated cultures. The two preservative transport systems were comparable for maintenance of viability of the pathogens, but there were fewer mixed cultures when samples were collected with Uriswab. This study confirms the importance of a standard volume of 1 μL of urine for culture. Copyright © 2016 Elsevier Inc. All rights reserved.
Rückert, Cornelia; Siener, Roswitha; Ganter, Martin; Coenen, Manfred; Vervuert, Ingrid
2016-08-17
Reduction of urolithic potential by means of increased water intake and urine dilution through supplementation of sodium chloride (NaCl) or decrease of urine pH by supplementation of ammonium chloride (NH4Cl) in rabbits. Sixteen female, 6-month-old dwarf rabbits received the following three feeding regimens in a random order: complete feed without supplements = control; complete feed + 10 g NaCl/kg feed = NaCl; complete feed + 2.5 g NH4Cl/kg feed = NH4Cl. The diets were fed ad libitum over a period of 27 days without roughage. Water was provided ad libitum by a drinker. A 14-day wash-out-period (hay feeding) was performed between the different diets. Blood, faeces, and urine were collected at the beginning of each feeding period, after 21-day adaptation to the respective diet, and after the 3-day collection period. The following parameters were analysed: water and food intake as well as acid-base balance and mineral content in blood, urine, and faeces. NaCl supplementation numerically increased the daily water intake from 40.5 ± 14.4 ml/kg body weight (BW) (control) up to 49.5 ± 14.3 ml/kg BW and significantly increased the daily urine volume from 16.9 ± 7.8 ml/kg BW (control group) to 21.1 ± 7.4 ml/kg BW. The specific gravity of urine samples from NaCl supplementation decreased from 1.060 ± 0.008 to 1.044 ± 0.008. NH4Cl supplementation did not induce significant changes in urine pH, blood acid-base parameters, or calcium retention. Relative supersaturations (RSS) for calcium oxalate and calcium phosphate showed no significant changes after treatment. RSS for struvite increased from 360 ± 735 (after hay feeding) to 3312 ± 6188 on control feeding, 2910 ± 4913 with NaCl supplementation, and 3022 ± 6635 with NH4Cl supplementation (p < 0.05). NaCl supplementation significantly increased the urine volume and decreased its specific gravity. Therefore, NaCl supplementation might be an additional dietary treatment to increase the elimination of urine crystals in rabbits. NH4Cl supplementation did not induce acidification of the urine.
Vaccarella, Salvatore; Söderlund-Strand, Anna; Franceschi, Silvia; Plummer, Martyn; Dillner, Joakim
2013-01-01
To evaluate the pattern of co-infection of human papillomavirus (HPV) types in both sexes in Sweden. Cell samples from genital swabs, first-void urine, and genital swabs immersed in first-void urine were collected in the present cross-sectional High Throughput HPV Monitoring study. Overall, 31,717 samples from women and 9,949 from men (mean age 25) were tested for 16 HPV types using mass spectrometry. Multilevel logistic regression was used to estimate the expected number of multiple infections with specific HPV types, adjusted for age, type of sample, and accounting for correlations between HPV types due to unobserved risk factors using sample-level random effects. Bonferroni correction was used to allow for multiple comparisons (120). Observed-to-expected ratio for any multiple infections was slightly above unity in both sexes, but, for most 2-type combinations, there was no evidence of significant departure from expected numbers. HPV6/18 was found more often and HPV51/68 and 6/68 less often than expected. However, HPV68 tended to be generally underrepresented in co-infections, suggesting a sub-optimal performance of our testing method for this HPV type. We found no evidence for positive or negative clustering between HPV types included in the current prophylactic vaccines and other untargeted oncogenic types, in either sex.
[Analysis on iodine nutritional status and thyroid function in pregnant women].
Li, Hongbo; Wang, Yanling; Zheng, Jing; Wang, Yancai; Huang, Dahong; Liang, Liping; Ren, Xudong; Dou, Yugui; Zhu, Xiaonan
2012-07-01
To investigate the iodine nutritional status and thyroid function of pregnant women during different periods of pregnancy, to provide evidence for guiding iodine supplementation for them. A cross-sectional survey was performed in 90 pregnant women in Wuwei City from April 2009 to January 2010. The morning blood samples and random urine samples were collected, and the thyroid-stimulating hormone (TSH), free triiodothyronine (FT3), free thyroid hormone (FT4), thyroglobulin antibodies (TGAb), thyroid microsomal antibodies (TMAb) in blood samples and iodine in urine samples were detected. The medians of urinary iodine were 231.49, 158.25 and 328.35 microg/L for women in early, middle and late period of pregnancy, The ratio of urinary iodine below 150 microg/L were 39.29%, 45.16% and 25.81%, respectively. The FT3, FT4 levels in the first trimester were higher than those in the third trimester (P < 0.05) and TSH level was increased, but no significant difference (P > 0.05). The positive rate of TGAb and TMAb antibody of pregnant women in different period of time were not significantly different (P > 0.05). The incidence of thyroid function disorder was significantly different in different gestation periods. Generally, the iodine nutritional status of these pregnant women was appropriate, but there was a tendency towards hypothyroid in some women. Monitoring urinary iodine and thyroid function in pregnant women should be carried out regularly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skierkowski, P.; Murphy, J.C.; Watson, E.S.
1978-03-01
The absorption of topically applied DTIC (5-(3,3-dimethyl-1-triazeno) imidazole-4-carboxamide-2-14C) (NSC-45388) was studied in female, weanling, Yorkshire white pigs. After 48 hours, an average of 9.61% of the topically applied dose was excreted in the urine of the test animals. Liver and kidney showed the most consistent uptake of radioactivity with heart and adrenal samples also showing significant uptake. Radioactivity was detected in random muscle samples at 6 hours after application, and in bone after 48 hours. A significant percentage of the applied dose was generally detected at and near the site of application.
Excretion profile of boldenone in urine of veal calves fed two different milk replacers.
Draisci, R; Merlanti, R; Ferretti, G; Fantozzi, L; Ferranti, C; Capolongo, F; Segato, S; Montesissa, C
2007-03-14
The residue profiles of 17alpha-/17beta-boldenone conjugated (17alpha/beta-Bol) and ADD were investigated by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in urine of male veal calves fed two commercial milk replacers, with different content of cholesterol and phytosterols. The urine samples were collected within 4 h after feeding and further from all the animals. Detectable amounts of 17alpha-Bol conjugated were measured in urine collected from all calves, but the concentrations of 17alpha-Bol were higher in urine from calves receiving the milk replacer with the greater amount of phytosterols. During the whole experiment, 17beta-Bol and ADD were never detected in urine samples collected.
Sample handling for mass spectrometric proteomic investigations of human urine.
Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid
2008-09-01
Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...
Performance of Copan WASP for Routine Urine Microbiology
Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.
2015-01-01
This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255
Fidani, M; Gamberini, M C; Pasello, E; Palazzoli, F; De Iuliis, P; Montana, M; Arioli, F
2009-01-01
Proper storage conditions of biological samples are fundamental to avoid microbiological contamination that can cause chemical modifications of the target analytes. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method through direct injection of diluted samples, without prior extraction, was used to evaluate the stability of phase II metabolites of boldenone and testosterone (glucuronides and sulphates) in intentionally poorly stored equine urine samples. We also considered the stability of some deuterated conjugated steroids generally used as internal standards, such as deuterated testosterone and epitestosterone glucuronides, and deuterated boldenone and testosterone sulphates. The urines were kept for 1 day at room temperature, to mimic poor storage conditions, then spiked with the above steroids and kept at different temperatures (-18 degrees C, 4 degrees C, room temperature). It has been possible to confirm the instability of glucuronide compounds when added to poorly stored equine urine samples. In particular, both 17beta- and 17alpha-glucuronide steroids were exposed to hydrolysis leading to non-conjugated steroids. Only 17beta-hydroxy steroids were exposed to oxidation to their keto derivatives whereas the 17alpha-hydroxy steroids were highly stable. The sulphate compounds were completely stable. The deuterated compounds underwent the same behaviour as the unlabelled compounds. The transformations were observed in urine samples kept at room temperature and at a temperature of 4 degrees C (at a slower rate). No modifications were observed in frozen urine samples. In the light of the latter results, the immediate freezing at -18 degrees C of the collected samples and their instant analysis after thawing is the proposed procedure for preventing the transformations that occur in urine, usually due to microbiological contamination. (c) 2008 John Wiley & Sons, Ltd.
Bao, T M; Tian, Y; Wang, L X; Wu, T; Lu, L N; Ma, H Y; Wang, L
2018-02-20
Objective: To investigate the levels of lanthanum, cerium, praseodymium, and neodymium in the blood, urine, and hair samples from residents in the rare earth mining area of a city in China, and to provide a scientific basis for the control of rare earth pollution and the protection of population health. Methods: A total of 147 residents who had lived in the rare earth mining area of a city for a long time were selected as the exposure group, and 108 residents in Guyang County of this city who lived 91 km away from the rare earth mining area were selected as the control group. Blood, urine, and hair samples were collected from the residents in both groups. Inductively coupled plasma mass spectrometry was used to determine the content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair samples. Results: In the exposure group, the median levels of lanthanum, cerium, praseodymium, and neodymium were 0.854, 1.724, 0.132, and 0.839 μg/L, respectively, in blood samples, 0.420, 0.920, 0.055, and 0.337 μg/L, respectively, in urine samples, and 0.052, 0.106, 0.012, and 0.045 μg/g, respectively, in hair samples. The exposure group had significantly higher levels of the four rare earth elements in blood, urine, and hair samples than the control group ( P <0.01) . Conclusion: The residents in the rare earth mining area of this city have higher content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair than those in the non-mining area; the content of cerium is highest, followed by lanthanum, neodymium, and praseodymium.
Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S
2016-01-01
Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively, across all urine samples. The results showed that median urinary 3-PBA concentrations were consistently the lowest in FMV samples (0.77 ng/mL, 0.68 ng/mL-SG, 0.68 ng/mg, and 0.58 ng/min) and the highest in 24-h samples (0.92 ng/mL, 1.06 ng/mL-SG, 1.18 ng/mg, and 1.19 ng/min) across all four methods. Intraclass correlation coefficient (ICC) estimates for 3-PBA indicated poor reproducibility (<0.22) for all urine sample types and methods over a day, week, and six weeks. Correcting for urine sample dilution, based on either SG, CR or urine output, introduced additional measurement variability both between- and within-individuals. These results indicate that a single measure of urinary 3-PBA was not sufficient to characterize average exposure regardless of sample type, correction method, and time frame of collection. In addition, the study results can be used to inform the design of exposure characterization strategies in relevant environmental epidemiology studies in the future. Published by Elsevier Inc.
Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N
2013-01-01
A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.
Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S
2006-01-01
Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.
Nilsson, Gunnel H; Kugelberg, Fredrik C; Ahlner, Johan; Kronstrand, Robert
2014-01-01
A simple liquid chromatography-tandem mass spectrometry method was validated to allow determination of zopiclone (ZOP), N-desmethylzopiclone (NDZOP), zopiclone N-oxide (ZOPNO) and 2-amino-5-chloropyridine (ACP) in urine at concentrations up to 3,000 ng/mL within 3.5 min. This method was used for quantitative analysis of the analytes in authentic urine samples obtained 10 h after oral administration of zopiclone (Imovane(®)) and in aliquots of the same urine samples after different storage conditions. In addition, pH of each studied urine sample was measured over time. The results showed that formation of ACP occurred at elevated pH and/or temperature by degradation of ZOP, NDZOP and ZOPNO. This method was also applied to samples obtained from two female victims of drug-facilitated assault. One sample had been exposed to long-term storage conditions at different temperatures and at pH >8.2, which resulted in high concentrations of ACP. The other sample, which was exposed to pH <6.5, showed no formation of ACP. ACP is formed both from ZOP and from its metabolites NDZOP and ZOPNO depending on the pH of the urine, time of storage and/or the temperature conditions. For correct interpretation in forensic cases, ZOP, its major metabolites and ACP should be analyzed. When ACP is identified in urine, the concentrations of ZOP, NDZOP and ZOPNO should be interpreted with great caution. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Laube, Norbert; Zimmermann, Diana J
2004-01-01
This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.
Khan, Latifa B; Read, Hannah M; Ritchie, Stephen R; Proft, Thomas
2017-01-01
Dipstick urinalysis is an informative, quick, cost-effective and non-invasive diagnostic tool that is useful in clinical practice for the diagnosis of urinary tract infections (UTIs), kidney diseases, and diabetes. We used dipstick urinalysis as a hands-on microbiology laboratory exercise to reinforce student learning about UTIs with a particular focus on cystitis, which is a common bacterial infection. To avoid exposure to potentially contaminated human urine samples, we prepared artificial urine using easily acquired and affordable ingredients, which allowed less-experienced students to perform urinalysis without the risk of exposure to pathogenic organisms and ensured reliable availability of the urine samples. This practical class taught medical students how to use urinalysis data in conjunction with medical history to diagnose diseases from urine samples and to determine a treatment plan for clinical scenarios.
Oliveira, Maria Isabel de; Namiyama, Gislene Mitsue; Cabral, Gabriela Bastos; Ferreira, João Leandro; Taniwaki, Noemi; Afonso, Ana Maria Sardinha; Lima, Isabella Rillo; Brigido, Luís Fernando Macedo de
2018-01-01
A great variety of viruses which cause exanthema share other clinical manifestations, making the etiologic identification a very difficult task, relying exclusively on the clinical examination. Rubella virus (RV) infection during the early stages of pregnancy can lead to serious birth defects, known as congenital rubella syndrome (CRS). In the present report, we described the presence of Zika virus (ZIKV) particles in urine samples and also ZIKV isolation in SIRC cells from the urine of a patient in acute phase of suspected rubella disease. The 50-year-old unvaccinated woman living in Sao Paulo, Brazil, was admitted to the emergency room with fever, headache, rash, arthralgia and prostration. Urine samples were collected for virus isolation and RT-qPCR. SIRC and Vero cells were inoculated with urine samples during 7 days. RT-qPCR was performed using measles virus (MV) and RV primers and both were found to be negative. After this result, RT-qPCR was performed for parvovirus B19, herpes virus 6 and ZIKV. The urine sample and the isolate were positive by Real Time PCR for ZIKV and negative for all other viruses tested. The sequences isolated are from the Asiatic lineage.
[The role of telomerase activity in non-invasive diagnostics of bladder cancer].
Glybochko, P V; Alyaev, J G; Potoldykova, N V; Polyakovsky, K A; Vinarov, A Z; Glukhov, A I; Gordeev, S A
2016-08-01
To evaluate the potentials of determining the telomerase activity (TA) in the cellular material of the urine for noninvasive diagnosis of bladder cancer (BC). Evaluation of TA was performed in the urine of 48 patients with bladder cancer (study group) before and after transurethral resection of the bladder wall (n=38), an open resection of the bladder (n=4), and cystectomy (n=6). TA was also evaluated in 48 tumor tissue samples obtained from these patients during removal of the bladder tumor. Each sample of the tumor tissue was separated into two parts, one of which was subjected to histological examination, and the latter was used to determine the telomerase activity. In all cases, the diagnosis of bladder cancer was confirmed morphologically. Determination of TA in the samples was performed by the modified TRAP-method (telomerase repeat amplification protocol), RT-PCR, PCR, and electrophoresis. As a control, cell material of the urine and tissue in 12 patients with chronic cystitis was investigated. TA before surgery was found in 45 (93.75%) of 48 samples of cellular material of the urine from patients with suspected bladder cancer. BC was histologically verified in all patients in this group. In the postoperative period, TA was not observed in the 48 samples of cellular material of the urine from patients with BC. In the control group of patients with histologically verified cystitis, weak TA was determined only in one sample of cellular material of the urine. The analysis indicates statistically significant predominance of patients with bladder cancer in case of TA in the urine (P=0.001). TA was detected in all samples of tumor tissue. We also analyzed the dependence of TA levels in urine and tissue on the degree of BC differentiation. In patients with highly differentiated BC, mean AT in the cellular materials of the urine was 0,61% (n=15), in patients with moderately differentiated BC - 0.95% (n=23), in patients with low-grade bladder cancer - 1.33% (n=10); in other words, increase in the TA levels with decreasing the degree of differentiation was observed. This finding can be used in the prognosis of the course of disease based on determining the TA level in these patients. Preliminary data indicate the possibility of use of determining the TA in cellular material of the urine for the diagnosis and monitoring of bladder cancer recurrence.
Kennedy, Mary Jayne; Griffin, Angela; Su, Ruifeng; Merchant, Michael; Klein, Jon
2011-01-01
Urinary proteomic profiling has potential to identify candidate biomarkers of renal injury in infants provided an adequate urine sample can be obtained. Although diapers are used to obtain urine for clinical evaluation, their use for proteomic analysis has not been investigated. We therefore performed feasibility studies on the use of diaper-extracted urine for 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Pediatric waste urine (2–20 mL) was applied to gel-containing, non-gel and cotton-gauze diapers and then mechanically expressed. Urine volume and total protein were measured pre- and post-extraction. Proteins were separated via 2D-PAGE following application of urine (20–40 mL) to each matrix. 2D-PAGE was also performed on clinical specimens collected using each diaper type. Differences in the adsorption and retention of urine volume and protein were noted between matrices. Non-gel and cotton-gauze diapers provided the best protein/volume recovery and the lowest interference with the Bradford assay. 2D-PAGE was also successfully completed using urine samples from both cotton fiber matrices. Conversely, samples from low-gel diapers demonstrated poor protein separation and reproducibility. Diapers containing cotton-fiber matrices appear adequate for 2D-PAGE. Qualitative and quantitative analyses of resolved proteins using replicate, high resolution gels will be required, however, before diaper-extracted urine can be applied in proteomic profiling. PMID:21137001
NASA Astrophysics Data System (ADS)
Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.
2016-05-01
Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.
Workplace drug testing in Italy: findings about second-stage testing.
Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo
2015-03-01
Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.
Berman, Elena S.F.; Fortsona, Susan L.; Snaith, Steven P.; Gupta, Manish; Baer, Douglas S.; Chery, Isabelle; Blanc, Stephane; Melanson, Edward L.; Thomson, Peter J; Speakman, John R.
2012-01-01
The stable isotopes of hydrogen (δ2H) and oxygen (δ18O) in human urine are measured during studies of total energy expenditure by the doubly labeled water method, measurement of total body water, and measurement of insulin resistance by glucose disposal among other applications. An ultrasensitive laser absorption spectrometer based on off-axis integrated cavity output spectroscopy was demonstrated for simple and inexpensive measurement of stable isotopes in natural isotopic abundance and isotopically enriched human urine. Preparation of urine for analysis was simple and rapid (approx. 25 samples per hour), requiring no decolorizing or distillation steps. Analysis schemes were demonstrated to address sample-to-sample memory while still allowing analysis of 45 natural or 30 enriched urine samples per day. The instrument was linear over a wide range of water isotopes (δ2H = −454 to +1702 ‰ and δ18O= −58.3 to +265 ‰). Measurements of human urine were precise to better than 0.65 ‰ 1σ for δ2H and 0.09 ‰ 1σ for δ18O for natural urines, 1.1 ‰ 1σ for δ2H and 0.13 ‰ 1σ for δ18O for low enriched urines, and 1.0 ‰ 1σ for δ2H and 0.08 ‰ 1σ for δ18O for high enriched urines. Furthermore, the accuracy of the isotope measurements of human urines was verified to better than ±0.81 ‰ in δ2H and ±0.13 ‰ in δ18O (average deviation) against three independent IRMS laboratories. The ability to immediately and inexpensively measure the stable isotopes of water in human urine is expected to increase the number and variety of experiments which can be undertaken. PMID:23075099
Born, M; Axmann, C; Kader, R; von Falkenhausen, M; Manka, C; Willinek, W A; Schild, H
2004-11-01
Renal excretion of orally or rectally applied Gastrografin is reported to be a reliable indicator of a perforation or a postoperative anastomotic dehiscence of the GI-tract. The study was conducted to determine whether increased attenuation of the urine measured by CT after oral or rectal application of Gastrografin can give reliable evidence of any leakage from the gastrointestinal tract. Urine samples of 33 patients, who underwent a Gastrografin-enhanced fluoroscopic examination of the esophagus or the GI-tract for different clinical reasons, were examined by CT. The samples had been taken immediately before and 60 to 90 minutes after application of 100 ml Gastrografin. The results were compared with those of 5 healthy volunteers, who took urine samples before, 30, 60, 90, and 120 minutes after drinking 100 ml of Gastrografin. Maximal attenuation of the volunteers' urine samples was achieved 60 to 90 minutes after Gastrografin application with a mean of 50 Hounsfield units (HU), SD = 17 HU. The urine of three patients with radiologically proven fistula or dehiscence of a GI-tract anastomosis had no relevant increase in attenuation. Three other cases without any clinical or radiological evidence of an anastomotic leak had a substantial increase in the attenuation of the urine probes (87, 110, and 290 HU, respectively). The CT-measured urine samples as evidence of renal excretion of orally or rectally applied Gastrografin are not reliable for the detection of leaks from the GI-tract.
Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof
2015-04-01
Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.
Vu, N T; Chaturvedi, A K; Canfield, D V
1999-05-31
Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.
Sakhi, Amrit Kaur; Sabaredzovic, Azemira; Cequier, Enrique; Thomsen, Cathrine
2017-12-01
Exposure to phthalates has been associated with reproductive and developmental toxicity. Data on levels of these compounds in the Norwegian population is limited. In this study, urine samples were collected from 48 mothers and their children in two counties in Norway. Eleven different phthalate metabolites originating from six commonly used phthalates in consumer products were determined. Concentrations of phthalate metabolites were significantly higher in children compared to mothers except for mono-ethyl phthalate (MEP). The mothers provided several urine samples during 24hours (h) and diurnal variation showed that the concentrations in the morning urine samples (24-8h) were significantly higher than at other time-periods for most of the phthalate metabolites. Intraclass correlation coefficients (ICCs) for 24-hour time-period were in the range of 0.49-0.81. These moderate to high ICCs indicate that one spot urine sample can be used to estimate the exposure to phthalates. Since a significant effect of time of day was observed, it is still advisable to standardize the collection time point to reduce the variation. For the mothers, the use of personal care products (PCPs) were less associated with morning urine samples than early day (8-12h) and evening (16-24h) urine samples. The use of perfume and hair products were positively associated with the urinary concentrations of low molecular weight phthalates. Use of shower soap and shampoo were positively associated with urinary concentration of di(2-ethylhexyl) phthalate (DEHP) metabolites. For children, face cream use was positively associated with phthalate metabolites in the morning samples, and hand soap use was negatively associated with concentration of urinary DEHP metabolites in afternoon/evening samples. Since different PCPs were associated with the urinary phthalate metabolites in different time-periods during a day, more than one spot urine sample might be required to study associations between urinary phthalate metabolites and the use of PCPs. Copyright © 2017 Elsevier B.V. All rights reserved.
Coca tea consumption causes positive urine cocaine assay.
Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy
2006-12-01
Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.
NASA Astrophysics Data System (ADS)
Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong
2014-11-01
Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.
Moreno-Pérez, Diego; Bressa, Carlo; Bailén, María; Hamed-Bousdar, Safa; Carmona, Manuel; Pérez, Margarita; González-Soltero, Rocío; Montalvo-Lominchar, Maria Gregoria; Carabaña, Claudia
2018-01-01
Nutritional supplements are popular among athletes to improve performance and physical recovery. Protein supplements fulfill this function by improving performance and increasing muscle mass; however, their effect on other organs or systems is less well known. Diet alterations can induce gut microbiota imbalance, with beneficial or deleterious consequences for the host. To test this, we performed a randomized pilot study in cross-country runners whose diets were complemented with a protein supplement (whey isolate and beef hydrolysate) (n = 12) or maltodextrin (control) (n = 12) for 10 weeks. Microbiota, water content, pH, ammonia, and short-chain fatty acids (SCFAs) were analyzed in fecal samples, whereas malondialdehyde levels (oxidative stress marker) were determined in plasma and urine. Fecal pH, water content, ammonia, and SCFA concentrations did not change, indicating that protein supplementation did not increase the presence of these fermentation-derived metabolites. Similarly, it had no impact on plasma or urine malondialdehyde levels; however, it increased the abundance of the Bacteroidetes phylum and decreased the presence of health-related taxa including Roseburia, Blautia, and Bifidobacterium longum. Thus, long-term protein supplementation may have a negative impact on gut microbiota. Further research is needed to establish the impact of protein supplements on gut microbiota. PMID:29534465
Moreno-Pérez, Diego; Bressa, Carlo; Bailén, María; Hamed-Bousdar, Safa; Naclerio, Fernando; Carmona, Manuel; Pérez, Margarita; González-Soltero, Rocío; Montalvo-Lominchar, Maria Gregoria; Carabaña, Claudia; Larrosa, Mar
2018-03-10
Nutritional supplements are popular among athletes to improve performance and physical recovery. Protein supplements fulfill this function by improving performance and increasing muscle mass; however, their effect on other organs or systems is less well known. Diet alterations can induce gut microbiota imbalance, with beneficial or deleterious consequences for the host. To test this, we performed a randomized pilot study in cross-country runners whose diets were complemented with a protein supplement (whey isolate and beef hydrolysate) ( n = 12) or maltodextrin (control) ( n = 12) for 10 weeks. Microbiota, water content, pH, ammonia, and short-chain fatty acids (SCFAs) were analyzed in fecal samples, whereas malondialdehyde levels (oxidative stress marker) were determined in plasma and urine. Fecal pH, water content, ammonia, and SCFA concentrations did not change, indicating that protein supplementation did not increase the presence of these fermentation-derived metabolites. Similarly, it had no impact on plasma or urine malondialdehyde levels; however, it increased the abundance of the Bacteroidetes phylum and decreased the presence of health-related taxa including Roseburia , Blautia , and Bifidobacterium longum . Thus, long-term protein supplementation may have a negative impact on gut microbiota. Further research is needed to establish the impact of protein supplements on gut microbiota.
Ultrasonic-based membrane aided sample preparation of urine proteomes.
Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L
2018-02-01
A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p < 0.05). The method matches the analytical minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.
Doggui, Radhouene; El Ati-Hellal, Myriam; Traissac, Pierre; El Ati, Jalila
2018-03-26
Urinary iodine concentration (UIC) is commonly used to assess iodine status of subjects in epidemiological surveys. As pre-analytical factors are an important source of measurement error and studies about this phase are scarce, our objective was to assess the influence of urine sampling conditions on UIC, i.e., whether the child ate breakfast or not, urine void rank of the day, and time span between last meal and urine collection. A nationwide, two-stage, stratified, cross-sectional study including 1560 children (6-12 years) was performed in 2012. UIC was determined by the Sandell-Kolthoff method. Pre-analytical factors were assessed from children's mothers by using a questionnaire. Association between iodine status and pre-analytical factors were adjusted for one another and socio-economic characteristics by multivariate linear and multinomial regression models (RPR: relative prevalence ratios). Skipping breakfast prior to morning urine sampling decreased UIC by 40 to 50 μg/L and the proportion of UIC < 100 μg/L was higher among children having those skipped breakfast (RPR = 3.2[1.0-10.4]). In unadjusted analyses, UIC was less among children sampled more than 5 h from their last meal. UIC decreased with rank of urine void (e.g., first vs. second, P < 0.001); also, the proportion of UIC < 100 μg/L was greater among 4th rank samples (vs. second RPR = 2.1[1.1-4.0]). Subjects' breakfast status and urine void rank should be accounted for when assessing iodine status. Providing recommendations to standardize pre-analytical factors is a key step toward improving accuracy and comparability of survey results for assessing iodine status from spot urine samples. These recommendations have to be evaluated by future research.
Curl, Cynthia L; Fenske, Richard A; Kissel, John C; Shirai, Jeffry H; Moate, Thomas F; Griffith, William; Coronado, Gloria; Thompson, Beti
2002-01-01
We analyzed organophosphorus pesticide exposure in 218 farm worker households in agricultural communities in Washington State to investigate the take-home pathway of pesticide exposure and to establish baseline exposure levels for a community intervention project. House dust samples (n = 156) were collected from within the homes, and vehicle dust samples (n = 190) were collected from the vehicles used by the farm workers to commute to and from work. Urine samples were obtained from a farm worker (n = 213) and a young child (n = 211) in each household. Dust samples were analyzed for six pesticides, and urine samples were analyzed for five dialkylphosphate (DAP) metabolites. Azinphosmethyl was detected in higher concentrations (p < 0.0001) than the other pesticides: geometric mean concentrations of azinphosmethyl were 0.53 micro g/g in house dust and 0.75 micro g/g in vehicle dust. Dimethyl DAP metabolite concentrations were higher than diethyl DAP metabolite concentrations in both child and adult urine (p < 0.0001). Geometric mean dimethyl DAP concentrations were 0.13 micro mol/L in adult urine and 0.09 micro mol/L in child urine. Creatinine-adjusted geometric mean dimethyl DAP concentrations were 0.09 micro mol/g in adult urine and 0.14 micro mol/g in child urine. Azinphosmethyl concentrations in house dust and vehicle dust from the same household were significantly associated (r2 = 0.41, p < 0.0001). Dimethyl DAP levels in child and adult urine from the same household were also significantly associated (r2 = 0.18, p < 0.0001), and this association remained when the values were creatinine adjusted. The results of this work support the hypothesis that the take-home exposure pathway contributes to residential pesticide contamination in agricultural homes where young children are present. PMID:12460819
Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus
2007-02-01
Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.
NASA Technical Reports Server (NTRS)
Feedback, Daniel L.; Cibuzar, Branelle R.
2009-01-01
The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.
Sachan, Dileep S; Yatim, Ayub M; Daily, James W
2002-06-01
This study was launched to determine comparative effects of corn oil (CO), safflower oil (SO), fish oil (FO) and palm oil (PO) on carnitine status and ethanol metabolism in rats. Twenty-four male Sprague-Dawley rats (300 g bw) were randomly divided into four groups (n = 6) and fed a semisynthetic diets containing fat as oils listed above. Blood and 24 hour urine samples were collected before and after dietary treatment and acute ethanol administration. Samples were analyzed for blood-ethanol concentration (BEC) and carnitine species. The diets containing FO and PO retarded ethanol metabolism compared to the diets containing CO and SO. The effect of these dietary fats on carnitine species in plasma and urine was varied before and after dietary treatment and following a single oral ethanol dose. The liver carnitine content was higher in the PO group after dietary and ethanol treatment. It is concluded that attenuation of ethanol clearance was related to unique fatty acid makeup of the oils that in part may be attributed to the composite ratio of saturated to unsaturated fatty acids in the oils.
Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.
Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P
2015-08-01
The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.
NASA Astrophysics Data System (ADS)
Ahmed, Hytham M.; Ebeid, Wael B.
2015-05-01
Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200 ng/ml respectively and recovery was >98% (n = 5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000 IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period.
Urine sampling and collection system optimization and testing
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Geating, J. A.; Koesterer, M. G.
1975-01-01
A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.
Pilot-Plant Demonstration of Wet Oxidation for Treatment of Shipboard Wastewaters.
1975-11-01
minus mg of COD removed in prior sampling )] Table I indicates that, when the reactor was last sampled after six injections Pf concentrated feces and urine ...oxidation of feces and urine is of an inorganic nature. The pH of most of the samples taken in thes tests was measured using indi- cator papers. All...BATCH EXPERIMENTS ON FECES AND URINE IN rRESENCE OF BARBER-COLMAN CO. CATALYST 10,480 ............. . E.1 lest Procedure ......... . E-3 E.2 Test
A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.
Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R
2017-07-01
The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.
S Herath, H M Ayala; Kawakami, Tomonori; Nagasawa, Shiori; Serikawa, Yuka; Motoyama, Ayuri; Chaminda, G G Tushara; Weragoda, S K; Yatigammana, S K; Amarasooriya, A A G D
2018-04-01
Chronic kidney disease of unknown etiology (CKDu) is spreading gradually in Sri Lanka. In the current research, 1,435 well water samples from all 25 districts of Sri Lanka, 91 rice samples, and 84 human urine samples from both CKDu-endemic and non-endemic areas in Sri Lanka were analyzed for arsenic, cadmium, lead, and chromium to detect whether toxic elements could be a cause of CKDu. The liver-type fatty acid binding protein (L-FABP) concentration and arsenic, cadmium, lead, and chromium concentrations of the urine samples were analyzed to determine the relation of L-FABP with arsenic, cadmium, lead, and chromium. High concentrations of arsenic, cadmium, lead, and chromium were not detected in the well water samples from CKDu-endemic areas. Arsenic, cadmium, and lead contents in the rice samples from both CKDu-endemic and non-endemic areas were well below the Codex standard. There were no relationships between the L-FABP concentration and concentrations of arsenic, cadmium, lead, and chromium in urine. In addition, arsenic, cadmium, lead, and chromium concentrations in human urine samples from CKDu-endemic areas were not significantly different from those from non-endemic areas. These findings indicated that arsenic, cadmium, lead, and chromium could not cause CKDu.
Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S
2015-09-01
The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.
Urine chromium as an estimator of air exposure to stainless steel welding fumes.
Sjögren, B; Hedström, L; Ulfvarson, U
1983-01-01
Welding stainless steel with covered electrodes, also called manual metal arc welding, generates hexavalent airborne chromium. Chromium concentrations in air and post-shift urine samples, collected the same arbitrarily chosen working day, showed a linear relationship. Since post-shift urine samples reflect chromium concentrations of both current and previous stainless steel welding fume exposure, individual urine measurements are suggested as approximate although not exact estimators of current exposure. This study evaluates the practical importance of such measurements by means of confidence limits and tests of validity.
Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert
2009-01-01
An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.
Presence of infective Epstein-Barr virus in the urine of patients with infectious mononucleosis.
Landau, Z; Gross, R; Sanilevich, A; Friedmann, A; Mitrani-Rosenbaum, S
1994-11-01
The presence of Epstein-Barr virus (EBV) in the blood and urine of 20 patients with infectious mononucleosis (IM) was investigated together with the clinical course of the disease, and in 9 patients up to 2-7 months after recovery. EBV DNA, analyzed by the polymerase chain reaction (PCR), was detected in the blood of all 20 patients from the first sample obtained and detected between 3 to 42 days from the beginning of symptoms and up to 2-3 months after recovery. In the urine, EBV DNA was detected in 15 out of 16 (93%) patients in the first sample obtained and detected between 3 to 50 days during the clinical course of the disease. In four patients EBV DNA was detected in the urine up to 3 months after full recovery. Seventeen out of 26 (65%) urine samples including 3 which were obtained 2-7 months after recovery infected B cells as assessed by PCR. Nine out of 12 (75%) urine samples tested induced Epstein-Barr nuclear antigen (EBNA) in the infected B-cell line. In addition to the persistence of EBV in the blood of IM patients, these studies show for the first time the presence of infective EBV in the urine during the clinical course of the disease and up to 7 months after full clinical recovery.
[Assessment of dietary intake and urinary excretion of sodium and potassium in adults].
Cornejo, Karen; Pizarro, Fernando; Atalah, Eduardo; Galgani, José E
2014-06-01
Hypertension is associated with elevated sodium and low potassium intakes. The determination of sodium and potassium intake by dietary records is inaccurate, being its measurement from 24-h urine collection the reference method. To determine urinary sodium and potassium excretion in adults. To compare dietary sodium and potassium intake and their excretion from an isolated urine sample against the reference method. Seventy healthy adults aged 35 ± 8 years with a body mass index 25 ± 2 kg/m² (36 women) were studied. Urine was collected over 24 h, including an isolated urine sample taken in fasting conditions. Additionally, three 24-h dietary records were performed. Reported sodium and potassium intake was 2,720 ± 567 and 1,068 ± 433 mg/day, respectively. In turn, urinary excretion of sodium and potassium was 4,770 ± 1,532 and 1,852 ± 559 mg/day, respectively. These latter values were significantly higher than those obtained by dietary records. Furthermore, the urinary sodium and potassium excretion estimated from an isolated urine sample was 4,839 ± 1,355 and 1,845 ± 494 mg/day, respectively. These values were similar to those obtained with a 24 h urine collection. Dietary records underestimated electrolyte intake when compared with the reference method. Using an isolated urine sample to estimate electrolyte intake may be a reliable alternative.
NASA Technical Reports Server (NTRS)
Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)
1973-01-01
An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.
Kolbach-Mandel, A M; Mandel, N S; Cohen, S R; Kleinman, J G; Ahmed, F; Mandel, I C; Wesson, J A
2017-04-01
Drug-related kidney stones are a diagnostic problem, since they contain a large matrix (protein) fraction and are frequently incorrectly identified as matrix stones. A urine proteomics study patient produced a guaifenesin stone during her participation, allowing us to both correctly diagnose her disease and identify proteins critical to this drug stone-forming process. The patient provided three random midday urine samples for proteomics studies; one of which contained stone-like sediment with two distinct fractions. These solids were characterized with optical microscopy and Fourier transform infrared spectroscopy. Immunoblotting and quantitative mass spectrometry were used to quantitatively identify the proteins in urine and stone matrix. Infrared spectroscopy showed that the sediment was 60 % protein and 40 % guaifenesin and its metabolite guaiacol. Of the 156 distinct proteins identified in the proteomic studies, 49 were identified in the two stone-components with approximately 50 % of those proteins also found in this patient's urine. Many proteins observed in this drug-related stone have also been reported in proteomic matrix studies of uric acid and calcium containing stones. More importantly, nine proteins were highly enriched and highly abundant in the stone matrix and 8 were reciprocally depleted in urine, suggesting a critical role for these proteins in guaifenesin stone formation. Accurate stone analysis is critical to proper diagnosis and treatment of kidney stones. Many matrix proteins were common to all stone types, but likely not related to disease mechanism. This protocol defined a small set of proteins that were likely critical to guaifenesin stone formation based on their high enrichment and high abundance in stone matrix, and it should be applied to all stone types.
Bihuniak, Jessica D.; Simpson, Christine A.; Sullivan, Rebecca R.; Caseria, Donna M.; Kerstetter, Jane E.; Insogna, Karl L.
2018-01-01
To determine the usefulness of urine urea (UU) as an index of dietary protein intake 10 postmenopausal women were enrolled and completed a randomized, double-blind, cross-over feeding trial, from September 2008 to May 2010, comparing ten days of a 45g whey supplement to ten days of a 45 g maltodextrin control. Urine nitrogen (UN), calcium (UCa), UU and bone turnover markers were measured at days 0, 7, and 10. Paired sample t tests, Pearson’s correlation statistic, and simple linear regression were used to assess differences between treatments, and associations among urinary metabolites. UN/urinary creatinine (UCreat) rose from 12.3 ± 1.7 g/g (99.6 ± 13.8 mmol/mmol) to 16.8 ± 2.2 g/g (135.5 ± 17.8 mmol/mmol) with whey supplementation but did not change with maltodextrin. Whey supplementation caused UCa to rise by 4.76 ± 1.84 mg (1.19 ± 0.46 mmol) without a change in bone turnover markers. Since our goal was to estimate protein intake from UN/UCreat, we used our data to develop the following equation: protein intake (g/d) = 71.221 + 1.719×(UN, g)/Creat, g) (R = 0.46, R2 = 0.21). As a more rapid and less costly alternative to UN/UCreat, we next determined if urinary urea (UU) could predict protein intake and found that protein intake (g/d) = 63.844 + 1.11×(UU, g/Creat, g) (R = 0.58, R2 = 0.34). These data indicate that UU/UCreat is at least as good a marker of dietary protein intake as is urinary nitrogen and easier to quantitate in nutrition intervention trials. PMID:23438496
Moustafa, Islam O F; Ali, Mohammed R A-A; Al Hallag, Moataz; Rabea, Hoda; Fink, James B; Dailey, Patricia; Abdelrahim, Mohamed E A
During mechanical ventilation medical aerosol delivery has been reported to be upto two fold greater with dry inhaled gas than with heated humidity. Urine levels at 0.5 h post dose (URSAL0.5%) has been confirmed as an index of lung deposition and 24 h (URSAL24%) as index of systemic absorption. Our aim was to determine the effect of humidification and aerosol device type on drug delivery to ventilated patients using urine levels. In a randomized crossover design, 36 (18female) mechanically ventilated patients were assigned to one of three groups. Groups 1 and 2 received 5000 μg salbutamol using vibrating mesh (VM) and jet nebulizers (JN), respectively, while group 3 received 1600 μg (16 puffs) of salbutamol via metered dose inhaler with AeroChamber Vent (MDI-AV). All devices were placed in the inspiratory limb of ventilator downstream from the humidifier. Each subject received aerosol with and without humidity at >24 h intervals with >12 h washout periods between salbutamol doses. Patients voided urine 15 min before each study dose and urine samples were collected at 0.5 h post dosing and pooled for the next 24 h. The MDI-AV and VM resulted in a higher percentage of urinary salbutamol levels compared to the JN (p < 0.05). Urine levels were similar between humidity and dry conditions. Our findings suggest that in-vitro reports overestimate the impact of dry vs. heated humidified conditions on the delivery of aerosol during invasive mechanical ventilation. Copyright © 2017 Elsevier Inc. All rights reserved.
High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.
Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna
2013-01-01
Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.
Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens
Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe
2015-01-01
Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240
Butler, Christopher C; Sterne, Jonathan Ac; Lawton, Michael; O'Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D
2016-07-01
The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Acutely unwell children <5 years presenting to 233 UK primary care sites. Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs' 'working diagnosis' had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were 'frankly contaminated' (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. © British Journal of General Practice 2016.
Doping control study of AICAR in post-race urine and plasma samples from horses.
Wong, Jenny K Y; Kwok, Wai Him; Chan, George H M; Choi, Timmy L S; Ho, Emmie N M; Jaubert, Murielle; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Cawley, Adam; Ming Williams, H; Keledjian, John; Brooks, Lydia; Chambers, Adam; Lin, Yuanyuan; Wan, Terence S M
2017-09-01
Acadesine, 5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control deliberate administration of AICAR to racehorses after establishment of an appropriate threshold. Herein we report our studies of AICAR in post-race equine urine and plasma samples including statistical studies of AICAR concentrations determined from 1,470 urine samples collected from thoroughbreds and standardbreds and analyzed in Australia, France, and Hong Kong. Quantification methods in equine urine and plasma using liquid chromatography-mass spectrometry were developed by the laboratories in each country. An exchange of spiked urine and plasma samples between the three countries was conducted, confirming no significant differences in the methods. However, the concentration of AICAR in plasma was found to increase upon haemolysis of whole blood samples, impeding the establishment of a suitable threshold in equine plasma. A possible urine screening cut-off at 600 ng/mL for the control of AICAR in racehorses could be considered for adoption. Application of the proposed screening cut-off to urine samples collected after intravenous administration of a small dose (2 g) of AICAR to a mare yielded a short detection time of approximately 4.5 h. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Butler, Christopher C; Sterne, Jonathan AC; Lawton, Michael; O’Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D
2016-01-01
Background The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. Aim To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Design and setting Acutely unwell children <5 years presenting to 233 UK primary care sites. Method Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Results Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs’ ‘working diagnosis’ had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were ‘frankly contaminated’ (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Conclusion Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. PMID:27364678
De, Prithwiraj; Amin, Anita G.; Valli, Eloise; Perkins, Mark D.; McNeil, Michael; Chatterjee, Delphi
2015-01-01
Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb), in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM) in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10–40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis. PMID:26633829
A population study of urine glycerol concentrations in elite athletes competing in North America.
Kelly, Brian N; Madsen, Myke; Sharpe, Ken; Nair, Vinod; Eichner, Daniel
2013-01-01
Glycerol is an endogenous substance that is on the World Anti-Doping Agency's list of prohibited threshold substances due to its potential use as a plasma volume expansion agent. The WADA has set the threshold for urine glycerol, including measurement uncertainty, at 1.3 mg/mL. Glycerol in circulation largely comes from metabolism of triglycerides in order to meet energy requirements and when the renal threshold is eclipsed, glycerol is excreted into urine. In part due to ethnic differences in postprandial triglyceride concentrations, we investigated urine glycerol concentrations in a population of elite athletes competing in North America and compared the results to those of athletes competing in Europe. 959 urine samples from elite athletes competing in North America collected for anti-doping purposes were analyzed for urine glycerol concentrations by a gas chromatography mass-spectrometry method. Samples were divided into groups according to: Timing (in- or out-of-competition), Class (strength, game, or endurance sports) and Gender. 333 (34.7%) samples had undetectable amounts of glycerol (<1 μg/mL). 861 (89.8%) of the samples had glycerol concentrations ≤20 μg/mL. The highest glycerol concentration observed was 652 μg/mL. Analysis of the data finds the effects of each category to be statistically significant. The largest estimate of the 99.9(th) percentile, from the in-competition, female, strength athlete samples, was 1813 μg/mL with a 95% confidence range from 774 to 4251 μg/mL. This suggests a conservative threshold of 4.3 mg/mL, which would result in a reasonable detection window for urine samples collected in-competition for all genders and sport classes. Copyright © 2013 John Wiley & Sons, Ltd.
Mutagenicity of urine from individuals exposed to LPG combustion products.
Yin, X J; Liu, J Z; Kong, X H; Chu, J H; Wang, H; Xiao, Z X
1998-09-01
The mutagenicity of urine from individuals exposed to the combustion products of liquefied petroleum gas (LPG) was detected with Salmonella typhimurium TA98 and its newly developed derivatives YG1021 (nitroreductase overproducing) and YG1024 (O-acetyltransferase overproducing). The detection showed significantly increased mutagenicity for the two YG strains and increased positive rates for all three strains in the presence of both rat liver S9 and beta-glucuronidase. Further analysis demonstrated that urine samples taken from smoking and non-smoking exposed individuals exhibited significantly higher mutagenic potency (revertants/10 microliters urine concentrate) than their corresponding controls. These results indicate that the increased urine mutagenicity is caused by the exposure to LPG combustion products or smoking. The mutagenic potency of urine samples of all exposed individuals tested with YG1024 was found to be about 7 times higher than with TA98. The difference in mutagenic potency was smaller for the same samples when comparison was made between YG1021 and TA98. This suggests that the mutagenic compounds present in the urine samples contain mainly aromatic compounds as glucuronide conjugates. Our results demonstrate that YG1024 is more sensitive than TA98 in detecting the mutagenicity of these samples. In addition, no significant difference in the mutagenic potency between the 'pure' exposed (non-smokers') and the 'pure' smokers' (unexposed) samples was found in all three tester strains. This might mean that the exposure extent of mutagens/carcinogens in LPG combustion products for exposed individuals roughly corresponds to the smoking level of smokers who smoke 20-40 cigarettes per day. Furthermore, the results also suggest that synergism might exist in the mutagenic effects of exposure to LPG combustion products and cigarette smoking.
Rosenthal, Richard N.; Ling, Walter; Casadonte, Paul; Vocci, Frank; Bailey, Genie L.; Kampman, Kyle; Patkar, Ashwin; Chavoustie, Steven; Blasey, Christine; Sigmon, Stacey; Beebe, Katherine L.
2015-01-01
Aims To evaluate safety and efficacy of buprenorphine implants (BI) versus placebo implants (PI) for the treatment of opioid dependence. A secondary aim compared BI to open-label sublingual buprenorphine/naloxone tablets (BNX). Design Randomized, double-blind, placebo-controlled trial. Subjects received either 4 buprenorphine implants (80 mg/implant) (n=114), 4 placebo implants (n=54), or open-label BNX (12–16 mg/d) (n=119). Setting 20 addiction treatment centers. Participants Adult outpatients (ages 18 to 65) with DSM-IV-TR opioid dependence. Measurements The primary efficacy endpoint was the percent of urine samples negative for opioids collected from weeks 1 to 24, examined as a cumulative distribution function (CDF). Findings The BI CDF was significantly different from placebo (P<.0001). Mean (95% CI) proportions of urines negative for opioids were: BI: 31.2% (25.3, 37.1) and PI: 13.4% (8.3, 18.6). BI subjects had a higher study completion rate relative to placebo (64% vs. 26%, P<.0001), lower clinician-rated (P<.0001) and patient-rated (P<.0001) withdrawal, lower patient-ratings of craving (P<.0001), and better subjects’ (P=.031) and clinicians’ (P=.022) global ratings of improvement. BI also resulted in significantly lower cocaine use (P=.0016). Minor implant-site reactions were comparable in the buprenorphine (27.2% [31/114]) and placebo groups (25.9% [14/54]). BI were non-inferior to BNX on percent urines negative for opioids [mean (95% CI): 33.5 (27.3, 39.6); CI for the difference of proportions, (−10.7, 6.2)]. Conclusions Compared with placebo, buprenorphine implants result in significantly less frequent opioid use, and are non-inferior to sublingual buprenorphine/naloxone tablets. PMID:23919595
Rosenthal, Richard N; Ling, Walter; Casadonte, Paul; Vocci, Frank; Bailey, Genie L; Kampman, Kyle; Patkar, Ashwin; Chavoustie, Steven; Blasey, Christine; Sigmon, Stacey; Beebe, Katherine L
2013-12-01
To evaluate the safety and efficacy of buprenorphine implants (BI) versus placebo implants (PI) for the treatment of opioid dependence. A secondary aim compared BI to open-label sublingual buprenorphine/naloxone tablets (BNX). Randomized, double-blind, placebo-controlled trial. Subjects received either four buprenorphine implants (80 mg/implant) (n = 114), four placebo implants (n = 54) or open-label BNX (12-16 mg/day) (n = 119). Twenty addiction treatment centers. Adult out-patients (ages 18-65) with DSM-IV-TR opioid dependence. The primary efficacy end-point was the percentage of urine samples negative for opioids collected from weeks 1 to 24, examined as a cumulative distribution function (CDF). The BI CDF was significantly different from placebo (P < 0.0001). Mean [95% confidence interval (CI)] proportions of urines negative for opioids were: BI = 31.2% (25.3, 37.1) and PI = 13.4% (8.3, 18.6). BI subjects had a higher study completion rate relative to placebo (64 versus 26%, P < 0.0001), lower clinician-rated (P < 0.0001) and patient-rated (P < 0.0001) withdrawal, lower patient-ratings of craving (P < 0.0001) and better subjects' (P = 0.031) and clinicians' (P = 0.022) global ratings of improvement. BI also resulted in significantly lower cocaine use (P = 0.0016). Minor implant-site reactions were comparable in the buprenorphine [27.2% (31 of 114)] and placebo groups [25.9% (14 of 54)]. BI were non-inferior to BNX on percentage of urines negative for opioids [mean (95% CI) = 33.5 (27.3, 39.6); 95% CI for the difference of proportions = (-10.7, 6.2)]. Compared with placebo, buprenorphine implants result in significantly less frequent opioid use and are non-inferior to sublingual buprenorphine/naloxone tablets. © 2013 Society for the Study of Addiction.
Badeli, Hamidreza; khoshnevis, Termeh; Hassanzadeh Rad, Afagh; Sadeghi, Mehrdad
2013-01-01
Vesicoureteral reflux (VUR) is a risk factor for kidney scarring, hypertension and declining renal function. Standard diagnostic methods are invasive and can cause exposure to radiation and urinary tract infections (UTIs). We aimed to investigate urine albumin and interleukin-8 levels as markers of ongoing VUR and renal damage in children without UTIs. Random urine samples were collected from 51 children, including 16 children with VUR (group A), 17 children with resolved VUR (group B) and 18 normal children (group C). The diagnosis of VUR or resolved VUR was confirmed by voiding cystourethrogram (VCUG) or direct radionuclide cystography (DRNC). All children had normal kidney function and had no evidence of UTI in the preceding three months. Random urine specimens were assayed for albumin (Alb), creatinine (Cr) and interleukin-8 (IL-8) and mean values were compared by one way ANOVA. In groups A and B, the mean age at first UTI was 31.7 ± 2.4 and 27 ± 2.0 months respectively. In group A, the mean duration between VUR diagnosis and study entrance was 30 ± 9.1 months. In group B, the mean duration between VUR diagnosis and recovery was 19.9 ± 1.3 months. Overall, 76.4% of affected children had bilateral VUR and 41.2% had severe VUR. There were no significant differences in urinary Alb, IL-8, Alb/Cr and IL-8/Cr between the three groups. The current study does not support the hypothesis that microalbuminuria or urinary IL-8 are good indicators of ongoing VUR and renal injury in children.
Sigdel, Tara K.; Salomonis, Nathan; Nicora, Carrie D.; Ryu, Soyoung; He, Jintang; Dinh, Van; Orton, Daniel J.; Moore, Ronald J.; Hsieh, Szu-Chuan; Dai, Hong; Thien-Vu, Minh; Xiao, Wenzhong; Smith, Richard D.; Qian, Wei-Jun; Camp, David G.; Sarwal, Minnie M.
2014-01-01
Early transplant dysfunction and failure because of immunological and nonimmunological factors still presents a significant clinical problem for transplant recipients. A critical unmet need is the noninvasive detection and prediction of immune injury such that acute injury can be reversed by proactive immunosuppression titration. In this study, we used iTRAQ -based proteomic discovery and targeted ELISA validation to discover and validate candidate urine protein biomarkers from 262 renal allograft recipients with biopsy-confirmed allograft injury. Urine samples were randomly split into a training set of 108 patients and an independent validation set of 154 patients, which comprised the clinical biopsy-confirmed phenotypes of acute rejection (AR) (n = 74), stable graft (STA) (n = 74), chronic allograft injury (CAI) (n = 58), BK virus nephritis (BKVN) (n = 38), nephrotic syndrome (NS) (n = 8), and healthy, normal control (HC) (n = 10). A total of 389 proteins were measured that displayed differential abundances across urine specimens of the injury types (p < 0.05) with a significant finding that SUMO2 (small ubiquitin-related modifier 2) was identified as a “hub” protein for graft injury irrespective of causation. Sixty-nine urine proteins had differences in abundance (p < 0.01) in AR compared with stable graft, of which 12 proteins were up-regulated in AR with a mean fold increase of 2.8. Nine urine proteins were highly specific for AR because of their significant differences (p < 0.01; fold increase >1.5) from all other transplant categories (HLA class II protein HLA-DRB1, KRT14, HIST1H4B, FGG, ACTB, FGB, FGA, KRT7, DPP4). Increased levels of three of these proteins, fibrinogen beta (FGB; p = 0.04), fibrinogen gamma (FGG; p = 0.03), and HLA DRB1 (p = 0.003) were validated by ELISA in AR using an independent sample set. The fibrinogen proteins further segregated AR from BK virus nephritis (FGB p = 0.03, FGG p = 0.02), a finding that supports the utility of monitoring these urinary proteins for the specific and sensitive noninvasive diagnosis of acute renal allograft rejection. PMID:24335474
Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.
Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali
2017-09-01
Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for the stabilization of EtG in urine samples.
Rapid determination of 226Ra in emergency urine samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.
2014-02-27
A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed.more » The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226Ra with DGA Resin, saving time. 133Ba was used instead of 225Ra as tracer to allow immediate counting; however, 225Ra can still be used as an option. The rapid purification of 226Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226Ra, with rapid removal of isobaric interferences.« less
Hayashi, Ami; Okada, Tomonari; Matsumoto, Hiroshi; Nagaoka, Yume; Wada, Toshikazu; Gondo, Asako; Nango, Tomoka; Miyaoka, Yoshitaka; Watanabe, Kanna; Iwata, Azusa; Nakao, Toshiyuki
2013-01-01
We investigate the validity of the assessment of urinary protein excretion by spot urine samples collected by different methods in outpatients with chronic kidney disease (CKD). SUBJECTS AND METHODS We obtained 24-hour urine and two spot urine samples, including the first morning urine and daytime urine in 159 CKD patients. Urinary protein excretion was assessed by the protein/creatinine ratio from spot urine samples (morning: m-UP (g/gCr), daytime: d-UP (g/gCr) ]. We examined the correlations and the differences among m-UP, d-UP and the actual urinary protein excretion obtained by 24-hour urine (a-UP(g/day) . Significant correlations were found between m-UP and a-UP, and between d-UP and a-UP (r = 0.88, 0.85; p < 0.001). Correlations between m-UP and a-UP were greater relative to those between d-UP and a-UP in patients with less than 3.5 g/day of a-UP and in patients with CKD stages 1 to approximately 3. The percent difference between m-UP and a-UP was--16.0 +/- 40.5%, and that between d-UP and a-UP was 27.1 +/- 72.9%. The absolute value of the percent difference between d-UP and a-UP tended to be greater than that between m-UP and a-UP (34.9 +/- 25.9% vs. 49.9 +/- 59.9%, p = 0.06). Urinary protein/creatinie ratio of the first morning urine is better approximate the urinary protein excretion obtained by 24-hour urine compared with that of spot urine in the daytime.
This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...
Optimization for Peptide Sample Preparation for Urine Peptidomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan
2014-02-25
Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less
Pichini, Simona; De Luca, Roberto; Pellegrini, Manuela; Marchei, Emilia; Rotolo, Maria Concetta; Spoletini, Roberta; D'Aloja, Paola; Pacifici, Roberta; Mortali, Claudia; Scaravelli, Giulia
2012-05-10
For the first time in Europe hair and urine testing have been applied to assess drugs of abuse consumption in couples undergoing assisted reproductive technology and the eventual association of toxic habits with other lifestyle, health status and sociodemographic factors was also investigated. Couples attending five assisted reproduction centers in Rome were invited to join the study. When they presented at the Centre for the visit, they were asked to answer a structured questionnaire concerning sociodemographic characteristics and lifestyle habits, and at the same time to provide hair and urine samples. Hair and urine testing for drugs of abuse, urinary profile of principal endogenous steroids involved in fertility process (testosterone, epitestosterone, androsterone, etiocholanolone and dehydroepiandrosterone) and of alcohol and tobacco smoke biomarkers were performed with validated methodologies. Of the 594 enrolled individuals (297 couples), 352 (164 couples and 24 single individuals from the couple) completed the questionnaire and gave both hair and urine samples, apart from 3 bald men, who only gave urine samples. Urine testing showed an overall 4.8% (17 individuals) positivity to drugs of abuse: 4.2% to cannabinoids, 1.4% to cocaine and 0.85% to both drugs. Results of 4cm segment hair samples testing matched those from urine samples. Thus, taking together, results of urine and hair testing confirmed repeated use of cannabis, cocaine and both drugs in 3.7, 0.85 and 0.57% examined individuals, respectively. Drug consumers were in a statistically higher percentage active smokers and alcohol drinkers, less prone to physical activity and with a trend towards higher weight than non consumers. Finally, repeated drug consumption was associated with significant lower concentration of urinary testosterone in males and of urinary dehydroepiandrosterone in females. The findings of the present study confirm the suitability of urine testing to disclose recent drugs of abuse consumption and of hair analysis to verify repeated consumption. Association between different toxic habits and sedentary lifestyle is also substantiated by the obtained results in our cohort of couples attending assisted reproduction centers. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki
2008-09-01
A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.
Ariyasu, S; Yanai, H; Sato, M; Shinno, Y; Taniguchi, K; Yamadori, I; Miki, Y; Sato, Y; Yoshino, T; Takahashi, K
2015-08-01
Methods for determining the origin of BK virus (BKV)-infected cells (decoy cells) in clinical urine samples have not been established although they could enhance the diagnosis of BKV infection in immunocompromised patients. We performed simultaneous immunostaining with anti-S100P (a urothelial marker) and anti-SV40 antibodies in 66 clinical urine samples exhibiting SV40 positivity and a decoy-cell appearance on Papanicolaou staining. The clinical voided urine samples included seven cases of renal transplantation, 47 cases of cancer therapy and 12 cases of non-neoplastic disease. SurePath(™) liquid-based cytology was used for the urine samples. BKV-infected cells were categorized as SV40(+)/S100P(+) and SV40 (+)/S100p(-). SV40(+)/S100P(-) cells were found in 55 cases (83.4%); nine cases (13.6%) carried both SV40(+)/S100P(-) and SV40(+)/S100P(+) cells. The former were identified as BKV infection in renal tubules and the latter in both the renal tubules and urothelial epithelia. The remaining two cases (3.0%) had only SV40(+)/S100P(+) cells of urothelial origin. Simultaneous immunostaining with anti-S100P and anti-SV40 is a useful method for determining the origin of BKV-infected cells in clinical urine samples from immunocompromised patients such as renal transplantation recipients. © 2014 John Wiley & Sons Ltd.
Martin, Paul; Cheung, S Y Amy; Yen, Mark; Han, David; Gillen, Michael
2016-01-01
The aims of the present study were to characterize the pharmacokinetics of fostamatinib in two phase I studies in healthy Japanese subjects after single- and multiple-dose administration, and to evaluate the utility of dried blood spot (DBS) sampling. In study A, 40 Japanese and 16 white subjects were randomized in a double-blind parallel group study consisting of seven cohorts, which received either placebo or a fostamatinib dose between 50 and 200 mg after single and multiple dosing. Pharmacokinetics of R406 (active metabolite of fostamatinib) in plasma and urine was assessed, and safety was intensively monitored. Study B was an open-label study that assessed fostamatinib 100 and 200 mg in 24 Japanese subjects. In addition to plasma and urine sampling (as for study A), pharmacokinetics was also assessed in blood. Mean maximum plasma concentration (C max) and area under total plasma concentration–time curve (AUC) increased with increasing dose in Japanese subjects. Steady state was achieved in 5–7 days for all doses. C max and AUC were both higher in Japanese subjects administered a 150-mg single dose than in white subjects. This difference was maintained for steady state exposure by day 10. Overall, R406 blood concentrations were consistent and ∼2.5-fold higher than in plasma. Minimal (<0.1 %) R406 was excreted in urine. Fostamatinib was well tolerated at all doses. Fostamatinib pharmacokinetics following single- and multiple-dose administration was approximately dose proportional at all doses ≤150 mg and greater than dose proportional at 200 mg in Japanese subjects. Japanese subjects administered fostamatinib 150 mg had higher exposure than white subjects. R406 could be measured in DBS samples and distributed into red blood cells, and DBS sampling was a useful method for assessing R406 pharmacokinetics.
Cao, Qiu-shi; Ba, Yuan-ming; Luo, Jun-hua; Dai, Qi
2015-02-01
To establish a method of high-performance liquid chromatography (HPLC) for determining the urine oxalate levle in rats with renal calcium oxalate calculus. Totally 24 SPF Wistar healthy male rats were randomly divided into control group(n=12)and ethylene glycol (EG) group (n=12). Rats in EG group were administered intragastrically with 2% ammonium chloride (AC)2 ml/rat per day+1% ethylene glycol (EG), along with free access to drinking water.The control group was fed with deionized water, along with the intragastric administration of normal saline (1 ml per day). Twenty-eight days after modelling, the 24-hour urine samples were collected, and the urine oxalic acid levels were determined using HPLC and the results were compared with those of catalytic spectrophotometry using oxidation of methyl. During the HPLC, the samples were separated on Aglient 5TC-C18 (250×4.6 mm,5 Μm), eluted with mixture of methanol (0.1 mol/L) and ammonium acetate (15:85) at 1.2 ml/min, and detected at 314 nm, with the column temperature being 20 ℃. The standard curves of high and low concentrations of oxalic acid were y=5909.1x+378730, R² =0.9984 and y=7810.5x-16635, R² =0.9967,respectively. The lowest detectable concentration in this method was 5 Μg/ml. The linear high concentration range of oxalate stood at 62.50-2000.00 Μg/ml, and the linear low concentration range of oxalate stood at 6.25-100.00 Μg/ml. Its average recovery was 95.1%, and its within-day and day-to-day precisions were 3.4%-10.8% and 3.8%-9.4%. Both HPLC and catalytic spectrophotometry showed significantly higher urinary oxalic acid concentration and 24 h urine oxalate level in EG group compared with the control group [urinary oxalic acid concentration: (736.35 ± 254.52) Μg/ml vs.(51.56 ± 36.34) Μg/ml,(687.35 ± 234.53) Μg/ml vs.(50.24 ± 42.34) Μg/ml;24 h urine oxalate level: (11.23 ± 4.12)mg vs.(0.87 ± 0.45)mg,(9.89 ± 3.55)mg vs. (0.77 ± 0.65)mg; all P<0.01]. No statistically significant difference was observed in the results of urinary oxalate concentration and 24 h urine oxalate level between HPLC and potassium chromate oxidation of methyl red spectrophotometry (all P>0.05). HPLC is a simple, rapid, and precise method in detecting urine oxalate level in rats with renal calcium oxalate calculus, with high recovery rate.
Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman
2016-01-01
The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer(®) Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.
Validation of a urine color scale for assessment of urine osmolality in healthy children.
Kavouras, Stavros A; Johnson, Evan C; Bougatsas, Dimitris; Arnaoutis, Giannis; Panagiotakos, Demosthenes B; Perrier, Erica; Klein, Alexis
2016-04-01
Urine color (UC) is a practical tool for hydration assessment. The technique has been validated in adults, but has not been tested in children. The purpose of the study was to test the validity of the urine color scale in young, healthy boys and girls, as a marker of urine concentration, investigate its diagnostic ability of detecting hypohydration and examine the ability of children to self-assess UC. A total of 210 children participated (age: 8-14 years, body mass: 43.4 ± 12.6 kg, height: 1.49 ± 0.13 m, body fat: 25.2 ± 7.8 %). Data collection included: two single urine samples (first morning and before lunch) and 24-h sampling. Hydration status was assessed via urine osmolality (UOsmo) and UC via the eight-point color scale. Mean UC was 3 ± 1 and UOsmo 686 ± 223 mmol kg(-1). UC displayed a positive relationship as a predictor of UOsmo (R (2): 0.45, P < 0.001). Based on the receiver operating curve, UC has good overall classification ability for the three samples (area under the curve 85-92 %), with good sensitivity (92-98 %) and specificity (55-68 %) for detecting hypohydration. The overall accuracy of the self-assessment of UC in the morning or the noon samples ranged from 67 to 78 %. Further threshold analysis indicated that the optimal self-assessed UC threshold for hypohydration was ≥4. The classical eight-point urine color scale is a valid method to assess hydration in children of age 8-14 years, either by researchers or self-assessment.
Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe
There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.
Molina, Laurence; Salvetat, Nicolas; Ameur, Randa Ben; Peres, Sabine; Sommerer, Nicolas; Jarraya, Fayçal; Ayadi, Hammadi; Molina, Franck; Granier, Claude
2011-12-10
The characterization of the normal urinary proteome is steadily progressing and represents a major interest in the assessment of clinical urinary biomarkers. To estimate quantitatively the variability of the normal urinary proteome, urines of 20 healthy people were collected. We first evaluated the impact of the sample conservation temperature on urine proteome integrity. Keeping the urine sample at RT or at +4°C until storage at -80°C seems the best way for long-term storage of samples for 2D-GE analysis. The quantitative variability of the normal urinary proteome was estimated on the 20 urines mapped by 2D-GE. The occurrence of the 910 identified spots was analysed throughout the gels and represented in a virtual 2D gel. Sixteen percent of the spots were found to occur in all samples and 23% occurred in at least 90% of urines. About 13% of the protein spots were present only in 10% or less of the samples, thus representing the most variable part of the normal urinary proteome. Twenty proteins corresponding to a fraction of the fully conserved spots were identified by mass spectrometry. In conclusion, a "public" urinary proteome, common to healthy individuals, seems to coexist with a "private" urinary proteome, which is more specific to each individual. Copyright © 2011 Elsevier B.V. All rights reserved.
Cytotoxic drug residues in urine of dogs receiving anticancer chemotherapy.
Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D
2010-01-01
The presence of cytotoxic drug residues in urine of dogs may represent an exposure risk for pet owners and other people as well as a potential environmental contaminant. However, studies on cytotoxic drug residues in excretions of clinical patients are lacking in veterinary oncology. Variable concentrations of cytotoxic residues are present in urine samples, depending on sampling time and substance. Client-owned dogs with lymphoma or mast cell tumors treated with standard chemotherapy protocols. Urine samples were collected before, directly after, and on days after administration of chemotherapy. Measurement of vincristine, vinblastine, cyclophosphamide, and doxorubicin residues in canine urine was performed by a quantitative liquid chromatography tandem mass spectrometry (LC/MS/MS) method. Median cyclophosphamide residue concentration was 398.2 microg/L directly after treatment (d0) and was below the level of detection on days 1-3 (d1, d2, d3). Median vincristine residue concentration was 53.8 microg/L directly after treatment and was 20.2, 11.4, and 6.6 microg/L on days 1, 2, and 3. Median vinblastine residues were 144.9 (d0), 70.8 (d1), 35.6 (d2), and 18.7 microg/L (d3) with low concentrations detectable for 7 days after treatment. Median urine doxorubicin concentrations were 354.0 (d0), 165.6 (d1), 156.9 (d2), and 158.2 microg/L (d3). Low concentrations of doxorubicin were measurable up to 21 days after administration. Variable concentrations of chemotherapeutics were measured in urine samples, depending on sampling time point and drug. Findings may inform current chemoprotection guidelines and help minimize exposure risks.
Prednisolone and prednisone neo-formation in bovine urine after sampling.
Arioli, F; Casati, A; Fidani, M; Silvestri, M; Pompa, G
2012-06-01
The rise in the frequency of detecting prednisolone in bovine urine from northern Italy has come into focus of attention in recent years. The possibility that neo-formation of prednisolone or that prednisone may occur in urine after collection of samples was therefore investigated. Cow urine collected for official routine controls in Lombardy containing more than 80 ng/ml cortisol, and prednisolone and prednisone below the decision limit (CCα) of the method (0.4 and 0.5 ng/ml, respectively) was used. The C1-2 dehydrogenation of naturally present cortisol and cortisone was checked by incubating urine, both contaminated and uncontaminated with faeces, at 37°C and by collecting samples at 0, 1, 2, 4, 6 and 24 h. The influence of Helix pomatia juice was also investigated in order to determine whether deconjugation could influence the reliability of the results. All samples were analysed by HPLC-MS3 for the presence of cortisol, cortisone, prednisolone and prednisone in negative electrospray ionisation mode, utilising the consecutive reaction monitoring of product ions derived from the formate molecular adduct ([M+HCOO]-). The observed neo-formation of prednisolone shows that inappropriate temperatures in sample storage and processing can result in an incorrect accusation of non-compliance. The faecal contamination of urine, performed with the aim to mimic a collection conducted without the necessary care, moreover, evoked a high increase in prednisolone concentration in two out of seven animals. Moreover, H. pomatia juice had no significant effect on the prednisolone concentration, indicating that this corticosteroid is present in its free form in cow urine.
Wu, Yiman; Li, Liang
2012-12-18
For mass spectrometry (MS)-based metabolomics, it is important to use the same amount of starting materials from each sample to compare the metabolome changes in two or more comparative samples. Unfortunately, for biological samples, the total amount or concentration of metabolites is difficult to determine. In this work, we report a general approach of determining the total concentration of metabolites based on the use of chemical labeling to attach a UV absorbent to the metabolites to be analyzed, followed by rapid step-gradient liquid chromatography (LC) UV detection of the labeled metabolites. It is shown that quantification of the total labeled analytes in a biological sample facilitates the preparation of an appropriate amount of starting materials for MS analysis as well as the optimization of the sample loading amount to a mass spectrometer for achieving optimal detectability. As an example, dansylation chemistry was used to label the amine- and phenol-containing metabolites in human urine samples. LC-UV quantification of the labeled metabolites could be optimally performed at the detection wavelength of 338 nm. A calibration curve established from the analysis of a mixture of 17 labeled amino acid standards was found to have the same slope as that from the analysis of the labeled urinary metabolites, suggesting that the labeled amino acid standard calibration curve could be used to determine the total concentration of the labeled urinary metabolites. A workflow incorporating this LC-UV metabolite quantification strategy was then developed in which all individual urine samples were first labeled with (12)C-dansylation and the concentration of each sample was determined by LC-UV. The volumes of urine samples taken for producing the pooled urine standard were adjusted to ensure an equal amount of labeled urine metabolites from each sample was used for the pooling. The pooled urine standard was then labeled with (13)C-dansylation. Equal amounts of the (12)C-labeled individual sample and the (13)C-labeled pooled urine standard were mixed for LC-MS analysis. This way of concentration normalization among different samples with varying concentrations of total metabolites was found to be critical for generating reliable metabolome profiles for comparison.
Impedimetric method for measuring ultra-low E. coli concentrations in human urine.
Settu, Kalpana; Chen, Ching-Jung; Liu, Jen-Tsai; Chen, Chien-Lung; Tsai, Jang-Zern
2015-04-15
In this study, we developed an interdigitated gold microelectrode-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for urinary tract infection (UTI) diagnosis. E. coli growth in human urine samples was successfully monitored during a 12-h culture, and the results showed that the maximum relative changes could be measured at 10Hz. An equivalent electrical circuit model was used for evaluating the variations in impedance characteristics of bacterial growth. The equivalent circuit analysis indicated that the change in impedance values at low frequencies was caused by double layer capacitance due to bacterial attachment and formation of biofilm on electrode surface in urine. A linear relationship between the impedance change and initial E. coli concentration was obtained with the coefficient of determination R(2)>0.90 at various growth times of 1, 3, 5, 7, 9 and 12h in urine. Thus our sensor is capable of detecting a wide range of E. coli concentration, 7×10(0) to 7×10(8) cells/ml, in urine samples with high sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.
Cox, Kyley J; Porucznik, Christina A; Anderson, David J; Brozek, Eric M; Szczotka, Kathryn M; Bailey, Nicole M; Wilkins, Diana G; Stanford, Joseph B
2016-04-01
Bisphenol A (BPA) is an endocrine disruptor and potential reproductive toxicant, but results of epidemiologic studies have been mixed and have been criticized for inadequate exposure assessment that often relies on a single measurement. Our goal was to describe the distribution of BPA concentrations in serial urinary specimens, assess temporal variability, and provide estimates of exposure classification when randomly selected samples are used to predict average exposure. We collected and analyzed 2,614 urine specimens from 83 Utah couples beginning in 2012. Female participants collected daily first-morning urine specimens during one to two menstrual cycles and male partners collected specimens during the woman's fertile window for each cycle. We measured urinary BPA concentrations and calculated geometric means (GM) for each cycle, characterized the distribution of observed values and temporal variability using intraclass correlation coefficients, and performed surrogate category analyses to determine how well repeat samples could classify exposure. The GM urine BPA concentration was 2.78 ng/mL among males and 2.44 ng/mL among females. BPA had a high degree of variability among both males (ICC = 0.18; 95% CI: 0.11, 0.26) and females (ICC = 0.11; 95% CI: 0.08, 0.16). Based on our more stringent surrogate category analysis, to reach proportions ≥ 0.80 for sensitivity, specificity, and positive predictive value (PPV) among females, 6 and 10 repeat samples for the high and low tertiles, respectively, were required. For the medium tertile, specificity reached 0.87 with 10 repeat samples, but even with 11 samples, sensitivity and PPV did not exceed 0.36. Five repeat samples, among males, yielded sensitivity and PPV values ≥ 0.75 for the high and low tertiles, but, similar to females, classification for the medium tertile was less accurate. Repeated urinary specimens are required to characterize typical BPA exposure. Cox KJ, Porucznik CA, Anderson DJ, Brozek EM, Szczotka KM, Bailey NM, Wilkins DG, Stanford JB. 2016. Exposure classification and temporal variability in urinary bisphenol A concentrations among couples in Utah-the HOPE study. Environ Health Perspect 124:498-506; http://dx.doi.org/10.1289/ehp.1509752.
Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; van Wyk, Gavin; Vogt, Monica; Pahlana, Pearl; Nicol, Mark P; Meintjes, Graeme
2015-08-14
Autopsy studies of HIV/AIDS-related hospital deaths in sub-Saharan Africa reveal frequent failure of pre-mortem diagnosis of tuberculosis (TB), which is found in 34-64 % of adult cadavers. We determined the overall prevalence and predictors of TB among consecutive unselected HIV-positive adults requiring acute hospital admission and the comparative diagnostic yield obtained by screening urine and sputum samples obtained on day 1 of admission with Xpert MTB/RIF (Xpert). To determine overall TB prevalence accurately, comprehensive clinical sampling (sputum, urine, blood plus other relevant samples) was done and TB was defined by detection of Mycobacterium tuberculosis in any sample using Xpert and/or mycobacterial liquid culture. To evaluate a rapid screening strategy, we compared the diagnostic yield of Xpert testing sputum samples and urine samples obtained with assistance from a respiratory study nurse in the first 24 h of admission. Unselected HIV-positive acute adult new medical admissions (n = 427) who were not receiving TB treatment were enrolled irrespective of clinical presentation or symptom profile. From 2,391 cultures and Xpert tests done (mean, 5.6 tests/patient) on 1,745 samples (mean, 4.1 samples/patient), TB was diagnosed in 139 patients (median CD4 cell count, 80 cells/μL). TB prevalence was very high (32.6 %; 95 % CI, 28.1-37.2 %; 139/427). However, patient symptoms and risk factors were poorly predictive for TB. Overall, ≥1 non-respiratory sample(s) tested positive in 115/139 (83 %) of all TB cases, including positive blood cultures in 41/139 (29.5 %) of TB cases. In the first 24 h of admission, sputum (spot and/or induced samples) and urine were obtainable from 37.0 % and 99.5 % of patients, respectively (P <0.001). From these, the proportions of total TB cases (n = 139) that were diagnosed by Xpert testing sputum, urine or both sputum and urine combined within the first 24 h were 39/139 (28.1 %), 89/139 (64.0 %) and 108/139 (77.7 %) cases, respectively (P <0.001). The very high prevalence of active TB and its non-specific presentation strongly suggest the need for routine microbiological screening for TB in all HIV-positive medical admissions in high-burden settings. The incremental diagnostic yield from Xpert testing urine was very high and this strategy might be used to rapidly screen new admissions, especially if sputum is difficult to obtain.
Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A
2017-04-01
The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.
Röhrich, J; Schimmel, I; Zörntlein, S; Becker, J; Drobnik, S; Kaufmann, T; Kuntz, V; Urban, R
2010-05-01
Cannabinoid concentrations in blood and urine after passive exposure to cannabis smoke under real-life conditions were investigated in this study. Eight healthy volunteers were exposed to cannabis smoke for 3 h in a well-attended coffee shop in Maastricht, Netherlands. An initial blood and urine sample was taken from each volunteer before exposure. Blood samples were taken 1.5, 3.5, 6, and 14 h after start of initial exposure, and urine samples were taken after 3.5, 6, 14, 36, 60, and 84 h. The samples were subjected to immunoassay screening for cannabinoids and analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol (THC), 11-nor-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH). It could be demonstrated that all volunteers absorbed THC. However, the detected concentrations were rather small. None of the urine samples produced immunoassay results above the cutoff concentration of 25 ng/mL. THC-COOH concentrations up to 5.0 and 7.8 ng/mL before and after hydrolysis, respectively, were found in the quantitative GC-MS analysis of urine. THC could be detected in trace amounts close to the detection limit of the used method in the first two blood samples after initial exposure (1.5 and 3.5 h). In the 6 h blood samples, THC was not detectable anymore. THC-COOH could be detected after 1.5 h and was still found in 3 out of 8 blood samples after 14 h in concentrations between 0.5 and 1.0 ng/mL.
Rabarijaona, L P; Andriamaroson, B J; Ravaoalimalala, V E; Ravoniarimbinina, P; Migliani, R
2001-01-01
Reduction of morbidity is the main component in the National Schistosomiasis Control Program in Madagascar. The lot quality assurance sampling (LQAS) method has previously been shown as a useful tool in assessment of immunization coverage. A study was carried in the western part of Madagascar aiming to evaluate the applicability of the method in measuring the level of Schistosoma haematobium endemic level in different communities. Parasitological examination of urine samples from 1,124 children aged 5 to 19 years from 12 different schools by use of filtration technique constituted the reference in determining the prevalence. Three schools were found hyper-endemic (prevalence more than 60%), 5 schools were intermediate-endemic (prevalence between 30 to 59%), and 4 were hypo-endemic (prevalence less than 30%). Those figures indicate a heterogeneous distribution of S. haematobium in the study area. A sampling plan (16.6) was then tested in the same area while other sampling plans were simulated in the laboratory. School teachers randomized under supervision the children to participate in this study and collected urine samples. All sampling plans (16.6), (14.5), (12.4), (10.3), (8.2), (6.1) et (4.0) allowed correct identification of hyper-endemic and hypo-endemic areas. Misclassifications occurred frequently for intermediate-endemic areas. The study confirms that the LQAS method by use of a (16.6) sampling plan constitute a valuable tool for large scale screening of hyper-endemic areas for therapeutic intervention as part of the control program. The study has also shown that school teachers may offer a potential source of manpower locally in such screening operations.
Tan, Susanna K; Sahoo, Malaya K; Milligan, Stephen B; Taylor, Nathaniel; Pinsky, Benjamin A
2017-10-01
Detection of Zika virus (ZIKV) RNA in urine is of increasing interest for the diagnosis of ZIKV infection. Pre-analytical variables can significantly impact the stability of RNA in urine. To determine optimal specimen processing protocols that would maximize detection of ZIKV RNA in urine by real-time, reverse transcriptase PCR, we investigated the effect of temperature, initial ZIKV concentration, use of nucleic acid stabilizers, and time on ZIKV RNA levels. Urine samples from healthy donors were spiked with ZIKV using the Exact Diagnostics ® ZIKV Verification Panel, a commercially available panel composed of heat-inactivated ZIKV, at concentrations of 5.0 log 10 copies/mL (ZIKV-high) and 4.0 log 10 copies/mL (ZIKV-low). Samples were stored at room temperature, 4°C, or -80°C and frozen aliquots were exposed to no stabilizer (urine), Buffer ATL (Qiagen, Germantown, MD), or DNA/RNA Shield (Zymo Research, Irvine, CA). ZIKV RNA levels in urine declined steadily at room temperature, though was not significant by 48h (ZIKV-high, p=0.09; ZIKV-low, p=0.20). ZIKV RNA titers were consistently higher when stored at 4°C, suggesting that storage at 4°C can slow the progression of RNA degradation. Freezing urine samples at -80°C resulted in a significant loss of detectable ZIKV RNA in the ZIKV-low group. ZIKV RNA was detected in 5/6 replicates at 3days, 1/6 replicates at 10days, and 1/3 replicates at 30days, with findings reproducible on repeat testing. Presence of either nucleic acid stabilizer in urine corrected this effect, and resulted in recovery of ZIKV RNA in all replicates. Use of a nucleic acid stabilizer in the ZIKV-high group did not add incremental benefit for the detection or quantitation of ZIKV RNA. ZIKV RNA is prone to degradation in urine with loss of detectable virus even when specimens are frozen at -80°C for 10days. Detection of ZIKV-positive urine samples, particularly those containing low ZIKV titers may be aided with the addition of a nucleic acid stabilizer during urine specimen processing. Copyright © 2017. Published by Elsevier B.V.
McGuire, Barry B; Bhanji, Yasin; Sharma, Vidit; Frainey, Brendan T; McClean, Megan; Dong, Caroline; Rimar, Kalen; Perry, Kent T; Nadler, Robert B
2015-06-01
We aimed to understand the characteristics of patients who are less likely to submit adequate urine collections at metabolic stone evaluation. Inadequate urine collection was defined using two definitions: (1) Reference ranges for 24-hour creatinine/kilogram (Cr/24) and (2) discrepancy in total 24-hour urine Cr between 24-hour urine collections. There were 1502 patients with ≥1 kidney stone between 1998 and 2014 who performed a 24- or 48-hour urine collection at Northwestern Memorial Hospital and who were identified retrospectively. Multivariate analysis was performed to analyze predictor variables for adequate urine collection. A total of 2852 urine collections were analyzed. Mean age for males was 54.4 years (range 17-86), and for females was 50.2 years (range 8-90). One patient in the study was younger than 17 years old. (1) Analysis based on the Cr 24/kg definition: There were 50.7% of patients who supplied an inadequate sample. Females were nearly 50% less likely to supply an adequate sample compared with men, P<0.001. Diabetes (odds ratio [OR] 1.42 [1.04-1.94], P=0.026) and vitamin D supplementation (OR 0.64 [0.43-0.95], P=0.028) predicted receiving an adequate/inadequate sample, respectively. (2) Analysis based on differences between total urinary Cr: The model was stratified based on percentage differences between samples up to 50%. At 10%, 20%, 30%, 40%, and 50% differences, inadequate collections were achieved in 82.8%, 66.9%, 51.7%, 38.5%, and 26.4% of patients, respectively. Statistical significance was observed based on differences of ≥40%, and this was defined as the threshold for an inadequate sample. Female sex (OR 0.73 [0.54-0.98], P=0.037) predicted supplying inadequate samples. Adequate collections were more likely to be received on a Sunday (OR 1.6 [1.03-2.58], P=0.038) and by sedentary workers (OR 2.3 [1.12-4.72], P=0.023). Urine collections from patients during metabolic evaluation for nephrolithiasis may be considered inadequate based on two commonly used clinical definitions. This may have therapeutic or economic ramifications and the propensity for females to supply inadequate samples should be investigated further.
Dunbar, Sandra B; Clark, Patricia C; Stamp, Kelly D; Reilly, Carolyn M; Gary, Rebecca A; Higgins, Melinda; Kaslow, Nadine
2016-01-01
Determine if family functioning influences response to family-focused interventions aimed at reducing dietary sodium by heart failure (HF) patients. Lowering dietary sodium by HF patients often occurs within the home and family context. Secondary analysis of 117 dyads randomized to patient and family education (PFE), family partnership intervention (FPI) or usual care (UC). Dietary sodium measures were obtained from 3-day food record and 24-h urine samples. In the poor family functioning groups, FPI and PFE had lower mean urine sodium than UC (p < .05) at 4 months, and FPI remained lower than UC at 8 months (p < .05). For good family functioning groups, FPI and PFE had lower mean sodium levels by 3-day food record at 4 and 8 months compared to the UC group. Optimizing family-focused interventions into HF clinical care maybe indicated. Copyright © 2016 Elsevier Inc. All rights reserved.
Gujral, L; Vaz, R G
2000-01-01
To assess the prevalence and identify levels of information and risk behavior associated with vesical schistosomiasis, a cross-sectional study was conducted in October-November 1996, involving students from 3 primary schools in the Primeiro de Junho health district in Maputo, Mozambique. Epidemiological interviews and urine samples were taken from 434 male and female students from grades 2 through 5, randomly selected. Estimated prevalence was 11.3% (49/434). Highest prevalence was in the age group ( 15 years old, and the highest intensity of infection among the 10-14-year age group, with 204 eggs/10 ml urine. Approximately 18.9% had heard of schistosomiasis, and of these, only 19.5% (16/82) knew how the disease is manifested. Approximately 50% of the students reported frequent water contacts with potential sources of schistosomiasis. The study shows that vesical schistosomiasis is a public health problem among students in this health district.
Majumdar, Deepanjan; Patel, Manoj; Drabar, Reena; Vyas, Manish
2006-11-01
The study was designed to understand the emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) from a single cattle urination event on a tropical grassland and underline the significance of the emissions in the context of huge animal population grazing on large pasture areas in some countries. Emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) were monitored for three weeks from a tropical grassland (dominated by Cynodon dactylon Pers.) microcosm contaminated with cow and buffalo urine. The grassland microcosms were treated with urine (50 and 100 ml of each) only once and irrigated with water once every week. Ammonia was sampled by an automatic sampling system comprising of a vacuum pump, three-way stopcocks and rubber tubing and an impinger containing suitable absorbing solution (H(2)SO(4)), connected to the tubing suitably. The sampled gas, after sucked by the vacuum pump and absorbed in H(2)SO(4), was allowed to enter the closed microcosm again maintaining internal pressure of the microcosm. Carbon dioxide was sampled by absorption in an alkali (NaOH) trap inside the microcosm. Both NH(3) and CO(2) emissions were highly variable temporally and there was no continuous increasing or decreasing emission trend with time. Respectively, 45 and 46% of total NH(3)-N were emitted within first 48 h from 50 and 100 ml cow urine application while the corresponding values for buffalo urine were 34 and 32%. Total NH(3)-N emissions, integrated for sampling days (i.e. 1, 2, 3, 4, 6, 15, 18 and 21st) were 11 and 6% in cow and 8 and 5% in buffalo urine, of the total-N added through 50 and 100 ml urine samples. Carbon dioxide emissions were standardized at 25 degrees C by using a suitable formula which were lower than actual emissions at actual soil temperature (> 25 degrees C). Carbon dioxide emission rates were classified on the basis of soil repiratory classification and classes ranged from moderately low soil activity up to unusually high soil activity, the latter observed only on very few sampling days. Grasses in the microcosm had shown appreciable growth after urine application. Although variable and somewhat unpredictable, emissions were appreciable and that too only from a patch of single urination, indicating to the huge magnitude of total emissions under the scenario of thousands of cattle grazing on hundreds of acres of grasslands in a tropical country.
Characterization of ultrafiltration of undiluted and diluted stored urine.
Ouma, J; Septien, S; Velkushanova, K; Pocock, J; Buckley, C
2016-11-01
Urine ultrafiltration (UF) was studied in terms of flux, permeability, resistance and fouling. Two types of samples were used: stored urine representing the feedstock obtained from urine diversion dry toilets; and diluted stored urine representing the feedstock obtained from urinals. Three different filtration experiment sets were adopted in this study. For the first case, pressure was set in an ascending order, i.e. from 10 to 60 kPa during filtration of stored urine. For the second case, pressure was set in a descending order, i.e. from 60 to 10 kPa for the same feed stream. The third case involved filtration of diluted urine with pressure in ascending order, i.e. from 10 to 60 kPa. The results indicated that diluted urine had higher flux than undiluted urine with maximum values of 43 and 26 L·m -2 ·h -1 respectively. Cake formation was the dominating fouling mechanism during urine filtration with a contribution of about 90% to the total hydraulic resistance. The contribution of chemically irreversible fouling was low (-2%), unless operating from high to low pressures. Indeed, irreversible fouling appeared to be greater during the experiments starting at higher pressure. Although undiluted urine had a higher fouling potential compared to diluted urine, the specific cake resistance was higher for diluted urine, probably due to a denser cake caused by lower particle sizes in that sample. The permeate obtained after urine filtration had much lower suspended solids content compared to the feedstock, with rejections up to 99%. The concentration of the ionic species remained unchanged, and 75% of the organic compounds and dissolved solids remained in the permeate. Urine UF could then be used as pre-treatment to remove suspended solids.
... Why do I need a nitrites in urine test? Your health care provider may have ordered a urinalysis as part ... Fever What happens during a nitrites in urine test? Your health care provider will need to collect a sample of ...
... Why do I need a urobilinogen in urine test? Your health care provider may have ordered this test as part ... skin What happens during a urobilinogen in urine test? Your health care provider will need to collect a sample of ...
Microbiological test results using three urine pretreatment regimes with 316L stainless steel
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1993-01-01
Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.
Carbon-monoxide poisoning in young drug addicts due to indoor use of a gasoline-powered generator.
Marc, B; Bouchez-Buvry, A; Wepierre, J L; Boniol, L; Vaquero, P; Garnier, M
2001-06-01
We report six fatal cases of unintentional carbon-monoxide poisoning which occurred in a house occupied by young people. The source of carbon monoxide was a gasoline-powered generator. For all victims, an external body examination was carried out and blood and urine samples collected. Blood carboxyhaemoglobin (COHb) was performed using an automated visible spectrophotometric analysis. Blood-alcohol level quantification was performed using gas chromatography and drug screening in urine was performed by a one-step manual qualitative immunochromatography (Syva Rapid test, Behring Diagnostics Inc.) for benzoylecgonine (the main metabolite of cocaine in urine), morphine, 11-nor-Delta(9)-THC-9-COOH (cannabinoids) and d-methamphetamine. In all victims the COHb value was as high or higher than 65%. No alcohol was found in blood samples, but urine samples were positive for methamphetamine, cocaine and cannabis in five cases and for opiates in one case. In four victims, the urine sample was positive for at least three drugs. The availability and accuracy of rapid toxicological screening is an important tool for the medical examiner at the immediate scene of a clinical forensic examination.
Uchikawa, Takuya; Yasutake, Akira; Kumamoto, Yoshimitsu; Maruyama, Isao; Kumamoto, Shoichiro; Ando, Yotaro
2010-02-01
Chlorella (Parachlorella beyerinckii CK-5), previously identified as Chlorella vulgaris CK-5, is a unicellular green algae that has for many years been used as a nutritional supplement. In order to investigate the effects of methylmercury (MeHg) detoxification by Chlorella, we examined the absorption and excretion of MeHg in mice. Female C57BL/6N mice were randomly divided into three groups of five, and were housed in metabolism cages. Mice were orally administered MeHg chloride at doses of 5 mg (4 mg Hg)/kg body weight with or without 100 mg/mouse of P. beyerinckii powder (BP), and were assigned to either a MeHg group or MeHg + BP group, accordingly. Twenty-four hr after oral administration, feces and urine were collected, and blood, liver, and kidney samples were obtained. Total mercury contents in the samples obtained were determined using an atomic absorption method. The amounts of Hg excreted in feces and urine of the MeHg + BP group were increased nearly 1.9 and 2.2-fold compared with those of the MeHg group. On the other hand, blood and organ Hg levels were not significantly different between two groups. These results suggest that the intake of BP may induce the excretion of Hg both in feces and urine, although it does not affect MeHg absorption from the gastrointestinal tract. The effect of BP on the tissue mercury accumulation may become evident in a long-term experiment.
Methodology for a vaginal and urinary microbiome study in women with mixed urinary incontinence.
Komesu, Yuko M; Richter, Holly E; Dinwiddie, Darrell L; Siddiqui, Nazema Y; Sung, Vivian W; Lukacz, Emily S; Ridgeway, Beri; Arya, Lily A; Zyczynski, Halina M; Rogers, Rebecca G; Gantz, Marie
2017-05-01
We describe the rationale and methods of a study designed to compare vaginal and urinary microbiomes in women with mixed urinary incontinence (MUI) and similarly aged, asymptomatic controls. This paper delineates the methodology of a supplementary microbiome study nested in an ongoing randomized controlled trial comparing a standardized perioperative behavioral/pelvic floor exercise intervention plus midurethral sling versus midurethral sling alone for MUI. Women in the parent study had at least "moderate bother" from urgency and stress urinary incontinence symptoms (SUI) on validated questionnaire and confirmed MUI on bladder diary. Controls had no incontinence symptoms. All participants underwent vaginal and urine collection for DNA analysis and conventional urine culture. Standardized protocols were designed, and a central lab received samples for subsequent polymerase chain reaction (PCR) amplification and sequencing of the bacterial16S ribosomal RNA (rRNA) gene. The composition of bacterial communities will be determined by dual amplicon sequencing of variable regions 1-3 and 4-6 from vaginal and urine specimens to compare the microbiome of patients with controls. Sample-size estimates determined that 126 MUI and 84 control participants were sufficient to detect a 20 % difference in predominant urinary genera, with 80 % power and 0.05 significance level. Specimen collection commenced January 2015 and finished April 2016. DNA was extracted and stored for subsequent evaluation. Methods papers sharing information regarding development of genitourinary microbiome studies, particularly with control populations, are few. We describe the rigorous methodology developed for a novel urogenital microbiome study in women with MUI.
Sachse, Daniel; Solevåg, Anne Lee; Berg, Jens Petter; Nakstad, Britt
2016-01-01
Optimizing resuscitation is important to prevent morbidity and mortality from perinatal asphyxia. The metabolism of cells and tissues is severely disturbed during asphyxia and resuscitation, and metabolomic analyses provide a snapshot of many small molecular weight metabolites in body fluids or tissues. In this study metabolomics profiles were studied in newborn pigs that were asphyxiated and resuscitated using different protocols to identify biomarkers for subject characterization, intervention effects and possibly prognosis. A total of 125 newborn Noroc pigs were anesthetized, mechanically ventilated and inflicted progressive asphyxia until asystole. Pigs were randomized to resuscitation with a FiO2 0.21 or 1.0, different duration of ventilation before initiation of chest compressions (CC), and different CC to ventilation ratios. Plasma and urine samples were obtained at baseline, and 2 h and 4 h after return of spontaneous circulation (ROSC, heart rate > = 100 bpm). Metabolomics profiles of the samples were analyzed by nuclear magnetic resonance spectroscopy. Plasma and urine showed severe metabolic alterations consistent with hypoxia and acidosis 2 h and 4 h after ROSC. Baseline plasma hypoxanthine and lipoprotein concentrations were inversely correlated to the duration of hypoxia sustained before asystole occurred, but there was no evidence for a differential metabolic response to the different resuscitation protocols or in terms of survival. Metabolic profiles of asphyxiated newborn pigs showed severe metabolic alterations. Consistent with previously published reports, we found no evidence of differences between established and alternative resuscitation protocols. Lactate and pyruvate may have a prognostic value, but have to be independently confirmed.
Spayd, Steven E.; Robson, Mark G.; Buckley, Brian T.
2014-01-01
A comparison of the effectiveness of whole house (point-of-entry) and point-of-use arsenic water treatment systems in reducing arsenic exposure from well water was conducted. The non-randomized observational study recruited 49 subjects having elevated arsenic in their residential home well water in New Jersey. The subjects obtained either point-of-entry or point-of-use arsenic water treatment. Prior ingestion exposure to arsenic in well water was calculated by measuring arsenic concentrations in the well water and obtaining water-use histories for each subject, including years of residence with the current well and amount of water consumed from the well per day. A series of urine samples were collected from the subjects, some starting before water treatment was installed and continuing for at least nine months after treatment had begun. Urine samples were analyzed and speciated for inorganic-related arsenic concentrations. A two-phase clearance of inorganic-related arsenic from urine and the likelihood of a significant body burden from chronic exposure to arsenic in drinking water were identified. After nine months of water treatment the adjusted mean of the urinary inorganic-related arsenic concentrations were significantly lower (p < 0.0005) in the point-of-entry treatment group (2.5 μg/g creatinine) than in the point-of-use treatment group (7.2 μg/g creatinine). The results suggest that whole house arsenic water treatment systems provide a more effective reduction of arsenic exposure from well water than that obtained by point-of-use treatment. PMID:24975493
Bos, R P; Kromhout, H; Ikink, H; de Haan, W; Koppejan, J; Theuws, J L
1989-05-01
In an aircraft type retreading plant environmental samples taken at several departments showed mutagenic properties. Thursday urine samples of non-smoking and smoking workers showed higher urinary mutagenicity than urine samples collected on Sundays, thus suggesting occupational exposure to mutagenic substances. A relation between urinary mutagenicity on Thursdays and skin contamination measured on Wednesdays was observed. The data suggest that intake through the skin plays an important role in the occupational exposure to mutagenic compounds of rubber workers.
Cheuvront, Samuel N; Muñoz, Colleen X; Kenefick, Robert W
2016-09-01
Urine concentration can be used to assess fluid intake adequacy or to diagnose dehydration. However, too often urine concentration is used inappropriately to draw dubious conclusions that could have harmful health and economic consequences. Inappropriate uses of urine concentration relate primarily to convenience sampling (timing) and problems related to convenience sampling (misapplication of thresholds), but a conceptual problem also exists with using urine concentration in isolation. The purpose of this Perspective article is to briefly explain the problematic nature of current practices and to offer a possible solution to improve practice with minimal added complication. When urine is used exclusively to assess fluid intake adequacy and hydration status in adults, we propose that only when urine concentration is high (>850 mmol/kg) and urine excretion rate is low (<850 mL/24 h) should suspicion of inadequate drinking or impending dehydration be considered. Prospective tests of the 850 × 850 thresholds will provide supporting evidence and/or help refine the best thresholds for men and women, young and old. © 2016 American Society for Nutrition.
Objective non-intrusive markers of sperm production and sexual activity
Sivananthan, Thilee; Bathur, Franz; Jimenez, Mark; Conway, Ann; Idan, Amanda; Handelsman, David
2012-01-01
Objective studies of men's reproductive function are hindered by their reliance on: (i) self-reporting to quantify sexual activity and (ii) masturbation to quantify sperm output rendering both types of estimate vulnerable to unverifiable subjective factors. We therefore examined whether detection of spermatozoa and measurement of prostate-specific antigen (PSA) in urine could provide objective semiquantitative estimates of sperm output and recent ejaculation, respectively, using widely available laboratory techniques. Of 11 healthy volunteers who provided urine samples before and at intervals for 5 days after ejaculation, sperm was present in 2/11 men before, and in all 11/11 samples immediately after ejaculation, but by the second and subsequent void, spermatozoa were present in ∼10%. PSA was detectable at high levels in all urine samples, peaking at the first post-ejaculatory sample but returning to baseline levels by the second post-ejaculatory void. We conclude that urinary spermatozoa and PSA are objective biomarkers for sperm production and sexual activity, but only for a short-time window until the first post-ejaculatory urine void. Hence, for a single urine specimen, the presence of spermatozoa and PSA are valid biomarkers, reflecting sperm production and recent ejaculation only until the next micturition, so their measurement should be restricted to the first morning urine void. PMID:22522506
Ahmed, Hytham M; Ebeid, Wael B
2015-05-15
Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200ng/ml respectively and recovery was >98% (n=5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period. Copyright © 2015 Elsevier B.V. All rights reserved.
Veland, Nicolas; Espinosa, Diego; Valencia, Braulio Mark; Ramos, Ana Pilar; Calderon, Flor; Arevalo, Jorge; Low, Donald E.; Llanos-Cuentas, Alejandro; Boggild, Andrea K.
2011-01-01
We hypothesized that Leishmania kDNA may be present in urine of patients with cutaneous leishmaniasis (CL). Urine samples and standard diagnostic specimens were collected from patients with skin lesions. kDNA polymerase chain reaction (PCR) was performed on samples from patients and 10 healthy volunteers from non-endemic areas. Eighty-six of 108 patients were diagnosed with CL and 18 (21%) had detectable Leishmania Viannia kDNA in the urine. Sensitivity and specificity were 20.9% (95% confidence interval [CI] 12.3–29.5%) and 100%. Six of 8 patients with mucocutaneous involvement had detectable kDNA in urine versus 12 of 78 patients with isolated cutaneous disease (P < 0.001). L. (V.) braziliensis (N = 3), L. (V.) guyanensis (N = 6), and L. (V.) peruviana (N = 3) were identified from urine. No healthy volunteer or patient with an alternate diagnosis had detectable kDNA in urine. Sensitivity of urine PCR is sub-optimal for diagnosis. On the basis of these preliminary data in a small number of patients, detectable kDNA in urine may identify less localized forms of infection and inform treatment decisions. PMID:21460009
Stamping SERS for creatinine sensing
NASA Astrophysics Data System (ADS)
Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan
2015-03-01
Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.
Pure human urine is a good fertiliser for cucumbers.
Heinonen-Tanski, Helvi; Sjöblom, Annalena; Fabritius, Helena; Karinen, Päivi
2007-01-01
Human urine obtained from separating toilets was tested as a fertiliser for cultivation of outdoor cucumber (Cucumis sativus L.) in a Nordic climate. The urine used contained high amounts of nitrogen with some phosphorus and potassium, but numbers of enteric microorganisms were low even though urine had not been preserved before sampling. The cucumber yield after urine fertilisation was similar or slightly better than the yield obtained from control rows fertilised with commercial mineral fertiliser. None of the cucumbers contained any enteric microorganisms (coliforms, enterococci, coliphages and clostridia). In the taste assessment, 11 out of 20 persons could recognise which cucumber of three cucumbers was different but they did not prefer one over the other cucumber samples, since all of them were assessed as equally good.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hawkins, C.; Dietz, M.; Kaminski, M.
2016-03-01
A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS
The Pesticide Metabolites in Urine data set contains the analytical results for measurements of up to 8 pesticide metabolites in 86 samples over 86 households. Each sample was collected form the primary respondent within each household. The sample consists of the first morning ...
The management of acute uncomplicated cystitis in adult women by family physicians in Canada
McIsaac, Warren J; Prakash, Preeti; Ross, Susan
2008-01-01
INTRODUCTION There are few Canadian studies that have assessed prescribing patterns and antibiotic preferences of physicians for acute uncomplicated cystitis. A cross-Canada study of adult women with symptoms of acute cystitis seen by primary care physicians was conducted to determine current management practices and first-line antibiotic choices. METHODS A random sample of 2000 members of The College of Family Physicians of Canada were contacted in April 2002, and were asked to assess two women presenting with new urinary tract symptoms. Physicians completed a standardized checklist of symptoms and signs, indicated their diagnosis and antibiotics prescribed. A urine sample for culture was obtained. RESULTS Of the 418 responding physicians, 246 (58.6%) completed the study and assessed 446 women between April 2002 and March 2003. Most women (412 of 420, for whom clinical information about antibiotic prescriptions was available) reported either frequency, urgency or painful urination. Physicians would have usually ordered a urine culture for 77.0% of the women (95% CI 72.7 to 80.8) and prescribed an antibiotic for 86.9% of the women (95% CI 83.3 to 90.0). The urine culture was negative for 32.8% of these prescriptions. The most commonly prescribed antibiotic was trimethoprim/sulfamethoxazole (40.8%; 95% CI 35.7 to 46.1), followed by fluoroquinolones (27.4%; 95% CI 22.9 to 32.3) and nitrofurantoin (26.6%; 95% CI 22.1 to 31.4). CONCLUSION Empirical antibiotic prescribing is standard practice in the community, but is associated with high levels of unnecessary antibiotic use. While trimethoprim/sulfamethoxazole is the first-line empirical antibiotic choice, fluoroquinolone antibiotics have become the second most commonly prescribed empirical antibiotic for acute cystitis. The effect of current prescribing patterns on community levels of quinolone-resistant Escherichia coli may need to be monitored. PMID:19436509
Nakashima, Kazufumi; Shigehara, Kazuyoshi; Kitamura, Tadaichi; Yaegashi, Hiroshi; Shimamura, Masayoshi; Kawaguchi, Shohei; Izumi, Kouji; Kadono, Yoshifumi; Mizokami, Atsushi
2018-05-11
The present study aimed to investigate human papillomavirus (HPV) prevalence and identify risk factors for HPV detection in urine samples among heterosexual men attending urological clinics. Spot urine samples including initial stream were collected from 845 participants, and the cell pellets were preserved into liquid-based cytological solution. After DNA extraction from each sample, HPV-DNA amplification and genotyping were performed using Luminex multiplex polymerase chain reaction. Participants completed a questionnaire on their age, education, smoking status, sexuality, age of sexual debut, marital status, and present history of sexually transmitted infections. Data from 803 patients were included in the analysis. Overall HPV and high-risk (HR)HPV prevalence in urine samples were 6.2% and 3.1%, respectively. HPV and HR-HPV prevalences were the highest in men with urethritis, and were significantly higher than those without urethritis. HPV detection was the most common in men aged 40-49 years, although significant detection differences were not age-related. Urethritis was an independent risk factor for HPV detection from urine samples, with an odds ratio (OR) of 4.548 (95%CI; 1.802-11.476) (p = 0.001). On the other hand, a sub-analysis excluding men with urethritis demonstrated that prostate cancer was a significant risk factor for HPV detection, with OR of 2.844 (95%CI; 1.046-7.732) (p = 0.0410), whereas was not a significant risk for HR-HPV detection in urine samples. Prostate cancer may represent a risk factor for HPV detection in the urine of men without urethritis. The authors did not register to Clinical Trial because this is observational and cross-sectional study. Copyright © 2018 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Detection of depleted uranium in urine of veterans from the 1991 Gulf War.
Gwiazda, R H; Squibb, K; McDiarmid, M; Smith, D
2004-01-01
American soldiers involved in "friendly fire" accidents during the 1991 Gulf War were injured with depleted-uranium-containing fragments or possibly exposed to depleted uranium via other routes such as inhalation, ingestion, and/or wound contamination. To evaluate the presence of depleted uranium in these soldiers eight years later, the uranium concentration and depleted uranium content of urine samples were determined by inductively coupled plasma mass spectrometry in (a) depleted uranium exposed soldiers with embedded shrapnel, (b) depleted uranium exposed soldiers with no shrapnel, and (c) a reference group of deployed soldiers not involved in the friendly fire incidents. Uranium isotopic ratios measured in many urine samples injected directly into the inductively coupled plasma mass spectrometer and analyzed at a mass resolution m/delta m of 300 appeared enriched in 235U with respect to natural abundance (0.72%) due to the presence of an interference of a polyatomic molecule of mass 234.81 amu that was resolved at a mass resolution m/delta m of 4,000. The 235U abundance measured on uranium separated from these urines by anion exchange chromatography was clearly natural or depleted. Urine uranium concentrations of soldiers with shrapnel were higher than those of the two other groups, and 16 out of 17 soldiers with shrapnel had detectable depleted uranium in their urine. In depleted uranium exposed soldiers with no shrapnel, depleted uranium was detected in urine samples of 10 out of 28 soldiers. The median uranium concentration of urines with depleted uranium from soldiers without shrapnel was significantly higher than in urines with no depleted uranium, though substantial overlap in urine uranium concentrations existed between the two groups. Accordingly, assessment of depleted uranium exposure using urine must rely on uranium isotopic analyses, since urine uranium concentration is not an unequivocal indicator of depleted uranium presence in soldiers with no embedded shrapnel.
Struys, E A; Jansen, E E W; Gibson, K M; Jakobs, C
2005-01-01
Succinic semialdehyde (SSA) accumulates in the inborn error of meta- bolism succinic semialdehyde dehydrogenase deficiency owing to impaired enzymatic conversion to succinic acid. We developed a stable-isotope dilution liquid chromato- graphy-tandem mass spectrometry method for the determination of SSA in urine and cerebrospinal fluid samples. Stable-isotope-labelled [13C4]SSA, serving as internal standard, was prepared by reaction of ninhydrin with L-[13C5]glutamic acid. SSA in body fluids was converted to its dinitrophenylhydrazine (DNPH) derivative, without sample purification prior to the derivatization procedure. The DNPH derivative of SSA was injected onto a C18 analytical column and chromatography was performed by isocratic elution. Detection was accomplished by tandem mass spectrometry operating in the negative multiple-reaction monitoring mode. The limit of detection was 10 nmol/L and the calibration curves over the range 0-500 pmol of SSA showed good linearity (r2 > 0.99). The intra-day coefficient of variation (n = 10) for urine was 2.7% and inter-day coefficient of variation (n = 5) for urine was 8.5%. The average recoveries performed on two levels by enriching urine and cerebrospinal fluid samples ranged between 85 and 115%, with coefficients of variation < 8%. The method enabled the first determination of normal values for SSA in urine and pathological values of SSA in urine and cerebrospinal fluid samples derived from patients with succinic semialdehyde dehydrogenase deficiency.
Urine Sample Preparation in 96-Well Filter Plates for Quantitative Clinical Proteomics
2015-01-01
Urine is an important, noninvasively collected body fluid source for the diagnosis and prognosis of human diseases. Liquid chromatography mass spectrometry (LC-MS) based shotgun proteomics has evolved as a sensitive and informative technique to discover candidate disease biomarkers from urine specimens. Filter-aided sample preparation (FASP) generates peptide samples from protein mixtures of cell lysate or body fluid origin. Here, we describe a FASP method adapted to 96-well filter plates, named 96FASP. Soluble urine concentrates containing ∼10 μg of total protein were processed by 96FASP and LC-MS resulting in 700–900 protein identifications at a 1% false discovery rate (FDR). The experimental repeatability, as assessed by label-free quantification and Pearson correlation analysis for shared proteins among replicates, was high (R ≥ 0.97). Application to urinary pellet lysates which is of particular interest in the context of urinary tract infection analysis was also demonstrated. On average, 1700 proteins (±398) were identified in five experiments. In a pilot study using 96FASP for analysis of eight soluble urine samples, we demonstrated that protein profiles of technical replicates invariably clustered; the protein profiles for distinct urine donors were very different from each other. Robust, highly parallel methods to generate peptide mixtures from urine and other body fluids are critical to increase cost-effectiveness in clinical proteomics projects. This 96FASP method has potential to become a gold standard for high-throughput quantitative clinical proteomics. PMID:24797144
Seasonal variation in natural abundance of 2H and 18O in urine samples from rural Nigeria
Dugas, Lara R.; Brieger, William; Tayo, Bamidele O.; Alabi, Tunrayo; Schoeller, Dale A.; Luke, Amy
2015-01-01
The doubly labeled water (DLW) method is used to measure free-living energy expenditure in humans. Inherent to this technique is the assumption that natural abundances of stable isotopes 2H and 18O in body water remain constant over the course of the measurement period and after elimination of the loading dose of DLW will return to the same predose level. To determine variability in the natural abundances of 2H and 18O in humans living in a region with seasonal shifts in rain patterns and sources of drinking water, over the course of 12 mo we collected weekly urine samples from four individuals living in southwest Nigeria as well as samples of their drinking water. From ongoing regional studies of hypertension, obesity, and energy expenditure, we estimated average water turnover rate, urine volumes, and sodium and potassium excretion. Results suggest that 2H and 18O in urine, mean concentrations of urinary sodium and potassium, urine volume, and total body turnover differed significantly from dry to rainy season. Additionally, seasonal weather variables (mean monthly maximum temperatures, total monthly rainfall, and minimum relative humidity) were all significantly associated with natural abundances in urine. No seasonal difference was observed in drinking water samples. Findings suggest that natural abundances in urine may not remain constant as assumed, and studies incorporating DLW measurements across the transition of seasons should interpret results with caution unless appropriate doses of the tracers are used. PMID:25977450
Chemical Method of Urine Volume Measurement
NASA Technical Reports Server (NTRS)
Petrack, P.
1967-01-01
A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.
Dehnes, Yvette; Shalina, Alexandra; Myrvold, Linda
2013-01-01
The misuse of microdoses of performance enhancing drugs like erythropoietin (EPO) constitutes a major challenge in doping analysis. When injected intravenously, the half-life of recombinant human EPO (rhEPO) like epoetin alfa, beta, and zeta is only a few hours and hence, the window for direct detection of rhEPO in urine is small. In order to investigate the detection window for rhEPO directly in blood and urine with a combined affinity chromatography and lateral flow immunoassay (EPO WGA MAIIA), we recruited nine healthy people who each received six intravenously injected microdoses (7.5 IU/kg) of NeoRecormon (epoetin beta) over a period of three weeks. Blood and urine samples were collected in the days following the injections and analyzed with EPO WGA MAIIA as well as the current validated methods for rhEPO; isoelectric focusing (IEF) and sarcosyl polyacrylamide gel electrophoresis (SAR-PAGE). For samples collected 18 h after a microdose, the sensitivity of the EPO WGA MAIIA assay was 100% in plasma and 87.5% in urine samples at the respective 98% specificity threshold levels. In comparison, the sensitivity in plasma and urine was 75% and 100%, respectively, with IEF, and 87.5% in plasma and 100% in urine when analyzed with SAR-PAGE. We conclude that EPO WGA MAIIA is a sensitive assay for the detection of rhEPO, with the potential of being a fast, supplemental screening assay for use in doping analysis.
Flow-injection chemiluminescence determination of melamine in urine and plasma.
Tang, Xiaoshuang; Shi, Xiyan; Tang, Yuhai; Yue, Zhongjin; He, Qiqi
2012-01-01
A novel flow-injection chemiluminescence method for the determination of melamine in urine and plasma was developed. It was found that melamine can remarkably enhance chemiluminescence emission from the luminol-K(3) Fe(CN)(6) system in an alkaline medium. Under the optimum conditions, chemiluminescence intensity had a good linear relationship with the concentration of melamine in the range 9.0 × 10(-9) -7.0 × 10(-6) g/mL, with a correlation coefficient of 0.9992. The detection limit (3σ) was 3.5 ng/mL. The method has been applied to determine the concentration of melamine in samples using liquid-liquid extraction. Average recoveries of melamine were 102.6% in urine samples and 95.1% in plasma samples. The method provided a reproducible and stable approach for the sensitive detection of melamine in urine and plasma samples. Copyright © 2011 John Wiley & Sons, Ltd.
Detection of West Nile virus lineage 2 in the urine of acute human infections.
Papa, Anna; Testa, Theodolinda; Papadopoulou, Elpida
2014-12-01
West Nile virus (WNV) lineage 2 emerged in Greece in 2010 and since then outbreaks in humans have been reported for four consecutive years. Laboratory diagnosis is based mainly on serology. A real-time RT-PCR was applied on urine samples obtained from 35 patients with acute WNV infection. WNV RNA was detected in 40% of the samples with cycle threshold (CT) values ranging from 26.95 to 39.89 (mean 33.11). WNV was isolated from two of four urine samples with low CT (<30). Viral load was not associated with patients' age, sex, day of illness, presence of WNV antibodies, and neurological symptoms. However, it seems that sample shipment and storage conditions are very important for virus detection and isolation. The usefulness of the WNV RNA detection in urine as a diagnostic tool of acute WNV infections is discussed. © 2014 Wiley Periodicals, Inc.
Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D
2006-03-01
Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.
Survey on Urinary Levels of Aflatoxins in Professionally Exposed Workers
Ferri, Fulvio; Brera, Carlo; De Santis, Barbara; Fedrizzi, Giorgio; Bacci, Tiziana; Bedogni, Lorena; Capanni, Sauro; Collini, Giorgia; Crespi, Enrica; Debegnach, Francesca; Ferdenzi, Patrizia; Gargano, Angelo; Gattei, Daniela; Luberto, Ferdinando; Magnani, Ines; Magnani, Massimo Giuseppe; Mancuso, Pamela; Menotta, Simonetta; Mozzanica, Stefania; Olmi, Milva; Ombrini, Giuseppe; Sala, Orietta; Soricelli, Sabina; Vicentini, Massimo; Giorgi Rossi, Paolo
2017-01-01
Feed mill workers may handle or process maize contaminated with aflatoxins (AFs). This condition may lead to an unacceptable intake of toxins deriving from occupational exposure. This study assessed the serological and urinary levels of AFs in workers exposed to potentially contaminated dusts in two mills. From March to April 2014, blood and urine samples were collected, on Monday and Friday morning of the same working week from 29 exposed workers and 30 non-exposed controls. AFs (M1, G2, G1, B1, B2) and aflatoxicol (AFOH) A were analyzed. Each subject filled in a questionnaire to evaluate potential food-borne exposures to mycotoxins. AFs contamination in environmental dust was measured in both plants. No serum sample was found to be positive. Seventy four percent of urine samples (73.7%) revealed AFM1 presence. AFM1 mean concentration was 0.035 and 0.027 ng/mL in exposed and non-exposed workers, respectively (p = 0.432); the concentration was slightly higher in Friday’s than in Monday’s samples, in exposed workers, 0.040 versus (vs.) 0.031 and non-exposed controls (0.030 vs. 0.024, p = 0.437). Environmental AFs contamination ranged from 7.2 to 125.4 µg/kg. The findings of this study reveal the presence of higher AFs concentration in exposed workers than in non-exposed controls, although these differences are to be considered consistent with random fluctuations. PMID:28338636
Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero
2006-01-01
Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.
Ferreira, João Pedro; Girerd, Nicolas; Medeiros, Pedro Bettencourt; Santos, Mário; Carvalho, Henrique Cyrne; Bettencourt, Paulo; Kénizou, David; Butler, Javed; Zannad, Faiez; Rossignol, Patrick
2016-06-01
Loop diuretic resistance characterized by inefficient sodium excretion complicates many patients with acutely decompensated heart failure (ADHF). Mineralocorticoid receptor antagonists (MRAs) in natriuretic doses may improve spot urine sodium excretion and outcomes. Our primary aim was to assess the association of high-dose spironolactone with short-term spot urine sodium excretion, and our secondary aim was to determine if this higher short-term spot urine sodium excretion is associated with reduction in the composite clinical outcome (of cardiovascular mortality and/or ADHF hospitalization) event rate at 180 days. Single-centre, non-randomized, open-label study enrolling 100 patients with ADHF. Patients were treated with standard ADHF therapy alone (n = 50) or oral spironolactone 100 mg/day plus standard ADHF therapy (n = 50). Spot urine samples were collected at day 1 and day 3 of hospitalization. Spironolactone group had significantly higher spot urine sodium levels compared to standard care group at day 3 (84.13 ± 28.71 mmol/L vs 70.74 ± 34.43 mmol/L, p = 0.04). The proportion of patients with spot urinary sodium <60 mmol/L was lower in spironolactone group at day 3 (18.8 vs 45.7, p = 0.01). In multivariate analysis, spironolactone was independently associated with increased spot urinary sodium and urinary sodium/potassium ratio of >2 at day 3 (both, p < 0.05). Higher spot urine sodium levels were associated with a lower event rate [HR for urinary sodium >100 mmol/L = 0.16 (0.06-0.42), p < 0.01, compared to <60], and provided a significant prognostic gain measured by net reclassification indexes. Spot urinary sodium levels >60 mmol/L and urinary sodium/potassium ratio >2 measured at day 3 of hospitalization for ADHF are associated with improved mid-term outcomes. Spironolactone is associated with increased spot urinary sodium and sodium/potassium ratio >2.
Polhuis, Kristel C M M; Wijnen, Annemarthe H C; Sierksma, Aafje; Calame, Wim; Tieland, Michael
2017-06-28
With ageing, there is a greater risk of dehydration. This study investigated the diuretic effect of alcoholic beverages varying in alcohol concentration in elderly men. Three alcoholic beverages (beer (AB), wine (AW), and spirits (S)) and their non-alcoholic counterparts (non-alcoholic beer (NAB), non-alcoholic wine (NAW), and water (W)) were tested in a diet-controlled randomized crossover trial. For the alcoholic beverages, alcohol intake equaled a moderate amount of 30 g. An equal volume of beverage was given for the non-alcoholic counterpart. After consumption, the urine output was collected every hour for 4 h and the total 24 h urine output was measured. AW and S resulted in a higher cumulative urine output compared to NAW and W during the first 4 h (effect size: 0.25 mL p < 0.003, effect size: 0.18 mL, p < 0.001, respectively), but not after the 24h urine collection ( p > 0.40, p > 0.10). AB and NAB did not differ at any time point (effect size: -0.02 mL p > 0.70). For urine osmolality, and the sodium and potassium concentration, the findings were in line. In conclusion, only moderate amounts of stronger alcoholic beverages, such as wine and spirits, resulted in a short and small diuretic effect in elderly men.
Gandasegui, Javier; Bajo Santos, Cristina; López-Abán, Julio; Saugar, José María; Rodríguez, Esperanza; Vicente, Belén; Muro, Antonio
2016-01-01
Background Strongyloides stercoralis, the chief causative agent of human strongyloidiasis, is a nematode globally distributed but mainly endemic in tropical and subtropical regions. Chronic infection is often clinically asymptomatic but it can result in severe hyperinfection syndrome or disseminated strongyloidiasis in immunocompromised patients. There is a great diversity of techniques used in diagnosing the disease, but definitive diagnosis is accomplished by parasitological examination of stool samples for morphological identification of parasite. Until now, no molecular method has been tested in urine samples as an alternative to stool samples for diagnosing strongyloidiasis. This study aimed to evaluate the use of a new molecular LAMP assay in a well-established Wistar rat experimental infection model using both stool and, for the first time, urine samples. The LAMP assay was also clinically evaluated in patients´ stool samples. Methodology/Principal Findings Stool and urine samples were obtained daily during a 28-day period from rats infected subcutaneously with different infective third-stage larvae doses of S. venezuelensis. The dynamics of parasite infection was determined by daily counting the number of eggs per gram of feces from day 1 to 28 post-infection. A set of primers for LAMP assay based on a DNA partial sequence in the 18S rRNA gene from S. venezuelensis was designed. The set up LAMP assay (namely, Strong-LAMP) allowed the sensitive detection of S. venezuelensis DNA in both stool and urine samples obtained from each infection group of rats and was also effective in S. stercoralis DNA amplification in patients´ stool samples with previously confirmed strongyloidiasis by parasitological and real-time PCR tests. Conclusions/Significance Our Strong-LAMP assay is an useful molecular tool in research of a strongyloidiasis experimental infection model in both stool and urine samples. After further validation, the Strong-LAMP could also be potentially applied for effective diagnosis of strongyloidiasis in a clinical setting. PMID:27415764
Fernández-Soto, Pedro; Sánchez-Hernández, Alicia; Gandasegui, Javier; Bajo Santos, Cristina; López-Abán, Julio; Saugar, José María; Rodríguez, Esperanza; Vicente, Belén; Muro, Antonio
2016-07-01
Strongyloides stercoralis, the chief causative agent of human strongyloidiasis, is a nematode globally distributed but mainly endemic in tropical and subtropical regions. Chronic infection is often clinically asymptomatic but it can result in severe hyperinfection syndrome or disseminated strongyloidiasis in immunocompromised patients. There is a great diversity of techniques used in diagnosing the disease, but definitive diagnosis is accomplished by parasitological examination of stool samples for morphological identification of parasite. Until now, no molecular method has been tested in urine samples as an alternative to stool samples for diagnosing strongyloidiasis. This study aimed to evaluate the use of a new molecular LAMP assay in a well-established Wistar rat experimental infection model using both stool and, for the first time, urine samples. The LAMP assay was also clinically evaluated in patients´ stool samples. Stool and urine samples were obtained daily during a 28-day period from rats infected subcutaneously with different infective third-stage larvae doses of S. venezuelensis. The dynamics of parasite infection was determined by daily counting the number of eggs per gram of feces from day 1 to 28 post-infection. A set of primers for LAMP assay based on a DNA partial sequence in the 18S rRNA gene from S. venezuelensis was designed. The set up LAMP assay (namely, Strong-LAMP) allowed the sensitive detection of S. venezuelensis DNA in both stool and urine samples obtained from each infection group of rats and was also effective in S. stercoralis DNA amplification in patients´ stool samples with previously confirmed strongyloidiasis by parasitological and real-time PCR tests. Our Strong-LAMP assay is an useful molecular tool in research of a strongyloidiasis experimental infection model in both stool and urine samples. After further validation, the Strong-LAMP could also be potentially applied for effective diagnosis of strongyloidiasis in a clinical setting.
A new method for quasi-reagent-free biomonitoring of mercury in human urine.
Schlathauer, Maria; Reitsam, Verena; Schierl, Rudolf; Leopold, Kerstin
2017-05-01
A novel analytical method for sampling and extraction of mercury (Hg) from human urine is presented in this work. The method is based on selective accumulation and separation of Hg from fresh urine sample onto active nanogold-coated silica material by highly efficient solid-phase extraction. After thermal desorption of Hg from the extractant, detection is performed by atomic fluorescence spectrometry (AFS). The feasibility and validity of the optimized, quasi-reagent-free approach was confirmed by recovery experiments in spiked real urine (recovery rate 96.13 ± 5.34%) and by comparison of found Hg concentrations in real urine samples - originating from occupationally exposed persons - with values obtained from reference methods cold vapor - atomic absorption spectrometry (CVAAS) and cold vapor - atomic fluorescence spectrometry (CV-AFS). A very good agreement of the found values reveals the validity of the proposed approach. The limit of detection (LOD) was found to be as low as 0.004 μg Hg L -1 and a high reproducibility with a relative standard deviations ≤4.2% (n = 6) is given. Moreover, storage of the samples for up to one week at an ambient temperature of 30 °C reveals no analyte losses or contamination. In conclusion, the proposed method enables easy-to-handle on-site extraction of total Hg from human urine ensuring at the same time reagent-free sample stabilization, providing quick and safe sampling, which can be performed by untrained persons. Copyright © 2017 Elsevier B.V. All rights reserved.
Jain, Raka; Quraishi, Rizwana; Verma, Arpita
2017-01-01
Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.
Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman
2016-01-01
Introduction The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Results Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. PMID:27346967
O'Brien, Kathryn; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C
2013-02-01
Urinary tract infection (UTI) in children may be associated with long-term complications that could be prevented by prompt treatment. To determine the prevalence of UTI in acutely ill children ≤ 5 years presenting in general practice and to explore patterns of presenting symptoms and urine sampling strategies. Prospective observational study with systematic urine sampling, in general practices in Wales, UK. In total, 1003 children were recruited from 13 general practices between March 2008 and July 2010. The prevalence of UTI was determined and multivariable analysis performed to determine the probability of UTI. Out of 597 (60.0%) children who provided urine samples within 2 days, the prevalence of UTI was 5.9% (95% confidence interval [CI] = 4.3% to 8.0%) overall, 7.3% in those < 3 years and 3.2% in 3-5 year olds. Neither a history of fever nor the absence of an alternative source of infection was associated with UTI (P = 0.64; P = 0.69, respectively). The probability of UTI in children aged ≥3 years without increased urinary frequency or dysuria was 2%. The probability of UTI was ≥5% in all other groups. Urine sampling based purely on GP suspicion would have missed 80% of UTIs, while a sampling strategy based on current guidelines would have missed 50%. Approximately 6% of acutely unwell children presenting to UK general practice met the criteria for a laboratory diagnosis of UTI. This higher than previously recognised prior probability of UTI warrants raised awareness of the condition and suggests clinicians should lower their threshold for urine sampling in young children. The absence of fever or presence of an alternative source of infection, as emphasised in current guidelines, may not rule out UTI in young children with adequate certainty.
Larsson, S; Struglics, A; Lohmander, L S; Frobell, R
2017-09-01
Prospectively monitor how treatment of acutely ruptured anterior cruciate ligament (ACL) affects biomarkers of inflammation and proteolytic degradation over 5 years. We studied 119 subjects with acute ACL injury from the randomized controlled knee anterior cruciate ligament, non-surgical versus surgical treatment (KANON)-trial (Clinical trial ISRCTN 84752559) who had synovial fluid, serum and urine samples available from at least two out of six visits over 5 years after acute ACL rupture. All subjects followed a similar rehabilitation protocol where, according to randomization, 60 also had early ACL reconstruction and 59 had the option to undergo a delayed ACL reconstruction if needed. Interleukin (IL)-6, IL-8, IL-10, interferon-gamma (IFNγ), tumor necrosis factor (TNF), amino acids alanine, arginine, glycine, serine (ARGS)-aggrecan, C-terminal crosslinking telopeptide type II collagen (CTX-II) and N-terminal crosslinking telopeptide type I collagen (NTX-I) were quantified by enzyme-linked immunosorbent assays (ELISA). Subjects randomized to early ACL reconstruction had higher cytokine concentrations in index knee synovial fluid at 4 months (IL-6, IL-8, IL-10, TNF), 8 months (IL-6 and TNF) and at 5 years (IFNγ) compared to those randomized to optional delayed reconstruction. Those that underwent delayed ACL reconstruction within 5 years (30 subjects), had higher synovial fluid concentrations of IL-6 at 5 years compared to those treated with rehabilitation alone. No differences between groups were noted for ARGS-aggrecan in synovial fluid and serum or CTX-II and NTX-I in urine over 5 years, neither as randomized nor as treated. Surgical ACL reconstruction constitutes a second trauma to the acutely injured joint resulting in a prolonged elevation of already high synovial fluid levels of inflammatory cytokines. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Measurement of Phenolic Environmental Estrogens in Women with Uterine Leiomyoma
Shen, Yang; Xu, Qian; Ren, Mulan; Feng, Xu; Cai, Yunlang; Gao, Yongxing
2013-01-01
Objectives To investigate the effect of phenolic environmental estrogens on uterine leiomyoma from the perspective of clinical epidemiology. Methods Urine and blood samples were collected from Han women with uterine leiomyoma and women without uterine leiomyoma, living in Nanjing, China, between September 2011 and February 2013. A total of 156 urine samples and 214 blood samples were collected from the uterine leiomyoma group and 106 urine samples and 126 blood plasma samples from the control group. Bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP) concentrations were determined by solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Results Phenolic environmental estrogens in the uterine leiomyoma and control groups were compared based on: gravida>3 and gravida ≤ 3. In participants with gravida>3, urine OP concentration was significantly (P<0.05) higher in the uterine leiomyoma group than in the control group. In participants with gravida ≤ 3, urine NP concentration was significantly (P<0.05) higher in the uterine leiomyoma group compared to controls. Despite obstetric history, urine BPA mean exposure concentration was significantly (P<0.05) different between uterine leiomyoma group and control group. The urine BPA concentration was not significantly (P>0.05) different between gravida>3 and gravida ≤ 3 patients. There was no significant (P>0.05) difference in plasma concentrations of BPA, OP and NP between the leiomyoma group and control group. Mean exposure concentration and range of distribution of BPA, OP and NP plasma concentration differed between the uterine leiomyoma and control group. Conclusion Exposure level of phenolic environmental estrogens in human was related with leiomyoma tumorigenesis. PMID:24255718
Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C
2017-08-01
Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Chatasingh, S; Tapaneya-Olarn, W
1989-01-01
The comparison of specific gravity values of 561 urine samples from TS meter and reagent strip was made. The data were divided into two groups: group 1-less than 2+ protein contained urine samples and group 2--equal or more than 2+ protein contained urine samples. The results revealed that the specific gravity values from both methods in both groups were statistically different (p less than 0.01) but they were correlated at r = 0.84 (p less than 0.001) and r = 0.73 (p less than 0.001) in group 1 and group 2, respectively. It was concluded that the reagent strip is suitable for use as a screening test but it should not be considered when precise measurement is necessary.
Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas
2007-01-01
Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.
Potential semiochemicals in urine from free ranging wolverines (Gulo gulo Pallas, 1780)
William F. Wood; Jeffrey P. Copeland; Richard E. Yates; Iman K. Horsey; Lynne R. McGreevy
2009-01-01
Urine deposition has been observed as an important scent-marking behaviour among wolverines (Gulo gulo, Mustelinae, Mustelidae). Solid phase microextraction (SPME) of headspace volatiles of the urine from free ranging wolverines were examined by gas chromatography-mass spectrometry (GC-MS). Urine samples were collected directly from the bladder of live-trapped animals...
Krishnan, Shilpa; Karg, Patricia E; Boninger, Michael L; Vodovotz, Yoram; Constantine, Greg; Sowa, Gwendolyn A; Brienza, David M
2016-10-01
To identify changes in concentrations of inflammatory mediators in plasma and urine after traumatic spinal cord injury (SCI) and before the occurrence of a first pressure ulcer. Retrospective; secondary analysis of existing data. Acute hospitalization and inpatient rehabilitation sites at a university medical center. Individuals with a pressure ulcer and plasma samples (n=17) and individuals with a pressure ulcer and urine samples (n=15) were matched by age and plasma/urine sample days to individuals with SCI and no pressure ulcer (N=35). Not applicable. Plasma and urine samples were assayed in patients with SCI, capturing samples within 4 days after the SCI to a week before the formation of the first pressure ulcer. The Wilcoxon signed-rank test was performed to identify changes in the inflammatory mediators between the 2 time points. An increase in concentration of the chemokine interferon-γ-induced protein of 10kd/CXCL10 in plasma (P<.01) and a decrease in concentration of the cytokine interferon-α in urine (P=.01) were observed before occurrence of a first pressure ulcer (∼4d) compared with matched controls. Altered levels of inflammatory mediators in plasma and urine may be associated with pressure ulcer development after traumatic SCI. These inflammatory mediators should be explored as possible biomarkers for identifying individuals at risk for pressure ulcer formation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Athar Masood, M; Veenstra, Timothy D
2017-08-26
Urine Drug Testing (UDT) is an important analytical/bio-analytical technique that has inevitably become an integral and vital part of a testing program for diagnostic purposes. This manuscript presents a tailor-made LC-MS/MS quantitative assay method development and validation for a custom group of 33 pain panel drugs and their metabolites belonging to different classes (opiates, opioids, benzodiazepines, illicit, amphetamines, etc.) that are prescribed in pain management and depressant therapies. The LC-MS/MS method incorporates two experiments to enhance the sensitivity of the assay and has a run time of about 7 min. with no prior purification of the samples required and a flow rate of 0.7 mL/min. The method also includes the second stage metabolites for some drugs that belong to different classes but have first stage similar metabolic pathways that will enable to correctly identify the right drug or to flag the drug that might be due to specimen tampering. Some real case examples and difficulties in peak picking were provided with some of the analytes in subject samples. Finally, the method was deliberated with some randomly selected de-identified clinical subject samples, and the data evaluated from "direct dilute and shoot analysis" and after "glucuronide hydrolysis" were compared. This method is now used to run routinely more than 100 clinical subjects samples on a daily basis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Pollution gets personal! A first population-based human biomonitoring study in Austria.
Hohenblum, Philipp; Steinbichl, Philipp; Raffesberg, Wolfgang; Weiss, Stefan; Moche, Wolfgang; Vallant, Birgit; Scharf, Sigrid; Haluza, Daniela; Moshammer, Hanns; Kundi, Michael; Piegler, Brigitte; Wallner, Peter; Hutter, Hans-Peter
2012-02-01
Humans are exposed to a broad variety of man-made chemicals. Human biomonitoring (HBM) data reveal the individual body burden irrespective of sources and routes of uptake. A first population-based study was started in Austria in 2008 and was finished at the end of May 2011. This cross sectional study aims at documenting the extent, the distribution and the determinants of human exposure to industrial chemicals as well as proving the feasibility of a representative HBM study. Overall, 150 volunteers (50 families) were selected by stratified random sampling. Exposure to phthalates, trisphosphates, polybrominated diphenyl ethers (PBDE), bisphenol A (along with nonyl- and octyl phenol) and methyl mercury was assessed. Sixteen of 18 PBDE determined were detected above the limit of quantification (LOQ) in blood samples with #153 and #197 the most abundant species. Bisphenol A in urine was measured in a subsample of 25 with only 4 samples found above the LOQ. In 3 of 100 urine samples at least one of 8 trisphosphate compounds assessed was above the LOQ. These first analytical results of the human biomonitoring data show that the body burden of the Austrian population with respect to the assessed compounds is comparable to or even lower than in other European countries. Overall, the study revealed that in order to develop a feasible protocol for representative human biomonitoring studies procedures have to be optimized to allow for non-invasive sampling of body tissues in accordance with the main metabolic pathways. Procedures of participants' recruitment were, however, labor intensive and have to be improved. Copyright © 2011 Elsevier GmbH. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brima, Eid I.; Haris, Parvez I.; Jenkins, Richard O.
2006-10-01
Very little is known about arsenic (As) metabolism in healthy populations that are not exposed to high concentrations of As in their food or water. Here we present a study with healthy volunteers from three different ethnic groups, residing in Leicester, UK, which reveals statistically significant differences in the levels of total As in urine and fingernail samples. Urine (n = 63), hair (n = 36) and fingernail (n = 36) samples from Asians, Somali Black-Africans and Whites were analysed using inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectroscopy (GF-AAS). The results clearly show that themore » total concentrations of As in urine and fingernail samples of a Somali Black-African population (urine 7.2 {mu}g/g creatinine; fingernails 723.1 {mu}g/kg) are significantly (P < 0.05) different from the Asian (urine 24.5 {mu}g/g creatinine; fingernails 153.9 {mu}g/kg) and White groups (urine 20.9 {mu}g/g creatinine; fingernails 177.0 {mu}g/kg). The chemical speciation of As in the urine of the three groups was also measured using high performance liquid chromatography coupled to ICP-MS. This showed that the proportion of the total urinary As present as dimethylarsenate (DMA) was higher for the Somali Black-African group (50%) compared to the Asians (16%) and Whites (22%). However, there was no significant difference (P > 0.05) in the level of As in the hair samples from these three groups; Somali Black-Africans (116.0 {mu}g/kg), Asians (117.4 {mu}g/kg) and Whites (141.2 {mu}g/kg). Significantly different levels of total As in fingernail and urine and a higher percentage of urinary DMA in the Somali Black-Africans are suggestive of a different pattern of As metabolism in this ethnic group.« less
Schwertner, Harvey A; Kong, Suk Bin
2005-03-09
Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.
NASA Astrophysics Data System (ADS)
Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero
2014-11-01
The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption-elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L- 1, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64-22.9 μg Pb L- 1).
Hughes, D L; Ritter, D J; Wilson, R D
2001-11-01
Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.
The International Space Station Urine Monitoring System (UMS)
NASA Technical Reports Server (NTRS)
Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.
2009-01-01
A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.
Harris, Susan S; Dawson-Hughes, Bess
2015-01-01
The aim of this study was to determine whether calcium supplementation, compared with placebo, increases urine calcium concentrations to levels indicative of increased renal stone risk, and the role that fluid intake, as indicated by urine volume, may play in mitigating this risk. This is a secondary analysis of data from a randomized placebo-controlled trial of 500 mg/d calcium supplementation to prevent bone loss. Subjects were 240 white postmenopausal women age 40 to 70 years in good general health. Effects of supplementation on 1-year changes in 24h urine calcium concentration and urine volume were examined. Both treatment group and urine volume were strong independent predictors of urine calcium concentration (p < 0.001). Among subjects with urine volume under 2 L/24 h, more than half of placebo subjects were at lowest risk for renal stones compared with less than 35% of calcium-supplemented subjects. Among those with higher urine volumes, all placebo subjects and more than 80% of calcium supplemented subjects were at lowest risk. The increased risk of renal stones with calcium supplement use may be largely eliminated with adequate fluid intake, but older adults may not spontaneously consume adequate fluids to minimize this risk and should be counseled to do so.
Zakrzewski, Robert; Ciesielski, Witold
2005-09-25
The reaction between iodine and azide ions induced by thiopental was utilized as a postcolumn reaction for chromatographic determination of thiopental. The method is based on the separation of thiopental on an Nova-Pak CN HP column with an acetonitrile-aqueous solution of sodium azide as a mobile phase, followed by spectrophotometric measurement of the residual iodine (lambda=350 nm) from the postcolumn iodine-azide reaction induced by thiopental after mixing an iodine solution containing iodide ions with the column effluent containing azide ions and thiopental. Chromatograms obtained for thiopental showed negative peaks as a result of the decrease in background absorbance. The detection limit (defined as S/N=3) was 20 nM (0.4 pmol injected amount) for thiopental. Calibration graphs, plotted as peak area versus concentrations, were linear from 40 nM. The elaborated method was applied to determine thiopental in urine samples. The detection limit (defined as S/N=3) was 0.025 nmol/ml urine. Calibration graphs, plotted as peak area versus concentrations, were linear from 0.05 nmol/ml urine. Authentic urine samples were analyzed, thiopental was determined at nmol/ml urine level.
Kazubek-Zemke, Maja; Rybka, Jacek; Marchewka, Zofia; Rybka, Wojciech; Pawlik, Krzysztof; Długosz, Anna
2014-11-14
The early diagnosis of the nephrotoxic effect of xenobiotics and drugs is still an unsolved problem. Recent studies suggest a correlation between the nephrotoxic activity of xenobiotics and increased concentration of amino acids in urine. The presented study was focused on the application of GLC-MS method for amino acids profiling in human urine as a noninvasive method for monitoring of kidney condition and tubular injury level. The analytic method is based on the conversion of the amino acids present in the sample to tert-butyldimethylsilyl (TBDMS) derivatives and their analysis by gas-liquid chromatography-mass spectrometry (GLC-MS). The procedure of urine sample preparation for chromatographic analysis was optimized. The presence of 12 amino acids in most of the tested healthy human urine samples was detected. The significant differences in the levels of particular amino acids between patients with tubular injury and healthy controls were found, especially for lysine, valine, serine, alanine and leucine (on average 30.0, 7.5, 3.6, 2.9 and 0.5 fold respectively). We found that this approach based on GLC-MS detection can be used in nephrotoxicity studies for urine amino acids monitoring in exposure to xenobiotics and drugs.
Detection and quantification of rituximab in the human urine.
Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario
2017-12-01
B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Mercadante, Rosa; Polledri, Elisa; Bertazzi, Pier Alberto; Fustinoni, Silvia
2013-10-01
The aim of this work was to evaluate short-term and long-term exposure to terbuthylazine (TBA) in agriculture workers (AW), rural residents (RR), and urban residents (UR) using urine and hair specimens. Twelve AW, 13 RR, and 17 UR were included in the study. Urine spot samples were collected with two different protocols. AW urine samples were collected before the application season (February, U0), at bedtime on the day of TBA application (March-May, U1), and prior to the next shift on the day after TBA application (U2). RR and UR urine samples were collected on any day during the application season (Ue). Hair samples were collected for all subjects before the application season (February, H0) and at the end of the season (June, H1). TBA and its metabolite desethylterbuthylazine (DET) were measured by liquid chromatography coupled with triple quadrupole mass spectrometry detection. DET was exclusively found in urine, while TBA was mostly found in the hair. In the AW, the urinary levels of DET were not detected in the U0 samples, and they increased to median levels of 1.81 and 2.94μg/L in the U1 and U2 samples, respectively (p<0.001). In the RR and UR, DET was not detected in the Ue samples. In the UR, TBA was not detected in the H0 samples, and the median levels of TBA were 0.01ng/mg hair in both the AW and RR. In the H1 samples, the median TBA levels were not detected, 0.01, and 0.08ng/mg hair in the UR, RR, and AW, respectively (p<0.001). Urinary DET and hair TBA are promising candidates for biomonitoring short- and long-term exposure to TBA. The use of this herbicide in agriculture leads to exposure in rural residents. © 2013.
Rossi, Gabriele; Giori, Luca; Campagnola, Simona; Zatelli, Andrea; Zini, Eric; Paltrinieri, Saverio
2012-06-01
To determine whether preanalytic and analytic factors affect evaluation of the urinary protein-to-creatinine (UPC) ratio in dogs. 50 canine urine samples. The UPC ratio was measured to assess the intra-assay imprecision (20 measurements within a single session), the influence of predilution (1:10, 1:20, and 1:100) for urine creatinine concentration measurement, and the effect of storage at room temperature (approx 20°C), 4°C, and -20°C. The coefficient of variation at room temperature determined with the 1:20 predilution was < 10.0%, with the highest coefficients of variation found in samples with a low protein concentration or low urine specific gravity. This variability could result in misclassification of samples with UPC ratios close to the thresholds defined by the International Renal Interest Society to classify dogs as nonproteinuric (0.2), borderline proteinuric (0.21 to 0.50), or proteinuric (> 0.51). A proportional bias was found in samples prediluted 1:10, compared with samples prediluted 1:20 or 1:100. At room temperature, the UPC ratio did not significantly increase after 2 and 4 hours. After 12 hours at room temperature and at 4°C, the UPC ratio significantly increased. The UPC ratio did not significantly change during 3 months of storage at -20°C. The intra-assay precision of the UPC ratio was sufficiently low to avoid misclassification of samples, except for values close to 0.2 or 0.5. The optimal predilution ratio for urine creatinine concentration measurement was 1:20. A 1:100 predilution is recommended in samples with a urine specific gravity > 1.030. The UPC ratio must be measured as soon as samples are collected. Alternatively, samples should be immediately frozen to increase their stability and minimize the risk of misclassification of proteinuria.
Uralets, Victor; App, Mike; Rana, Sumandeep; Morgan, Stewart; Ross, Wayne
2014-03-01
2-Ethylamino-1-phenylbutane (EAPB) and 2-amino-1-phenylbutane (APB) were identified by gas chromatography-mass spectrometry in multiple urine samples submitted for stimulant drug testing and screened positive for amphetamines by enzyme immunoassay. Forty-two samples from all over the USA were found, containing both analytes during a 3-month period May-July 2013. A sports dietary supplement 'CRAZE' has been determined to be one of the sources of EAPB supply. EAPB along with its suggested metabolite APB were detected in a urine sample, obtained from a person known to use 'CRAZE'.
Zhang, Su-jing; Luo, Ru-xin; Ma, Dong; Zhuo, Xian-yi
2016-04-01
To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.
Huang, Rongfu; Han, Sungyub; Li, Xiao Sheryl
2013-08-01
The nicotine metabolites, cotinine and trans-3'-hydroxycotinine (3HC) are considered as superior biomarkers for identifying tobacco exposure. More importantly, the ratio of 3HC to cotinine is a good indicator to phenotype individuals for cytochrome P450 2A6 activity and to individualize pharmacotherapy for tobacco addiction. In this paper, a simple, robust and novel method based on surface-enhanced Raman spectroscopy coupled with thin-layer chromatography (TLC) was developed to directly quantify the biomarkers in human urine samples. This is the first time surface-enhanced Raman spectroscopy (SERS) was used to detect cotinine and 3HC in urine samples. The linear dynamic range for the detection of cotinine is from 40 nM to 8 μM while that of 3HC is from 1 μM to 15 μM. The detection limits are 10 nM and 0.2 μM for cotinine and 3HC, respectively. The proposed method was further validated by quantifying the concentration of both cotinine and 3HC in smokers' urine samples. This TLC-SERS method allows the direct detection of cotinine in the urine samples of both active and passive smokers and the detection of 3HC in smokers.
Smartphone-based, sensitive µPAD detection of urinary tract infection and gonorrhea.
Cho, Soohee; Park, Tu San; Nahapetian, Tigran G; Yoon, Jeong-Yeol
2015-12-15
The presence of bacteria in urine can be used to monitor the onset or prognosis of urinary tract infection (UTI) and some sexually-transmitted diseases (STDs), such as gonorrhea. Typically, bacteria's presence in urine is confirmed by culturing samples overnight on agar plates, followed by a microscopic examination. Additionally, the presence of Escherichia coli in a urine sample can be indirectly confirmed through assaying for nitrite (generated by reducing nitrate in urine), however this is not sufficiently specific and sensitive. Species/strains identification of bacteria in a urine sample provides insight to appropriate antibiotic treatment options. In this work, a microfluidic paper analytical device (µPAD) was designed and fabricated for evaluating UTI (E. coli) and STD (Neisseria gonorrhoeae) from human urine samples. Anti-E. coli or anti-N. gonorrhoeae antibodies were conjugated to submicron particles then pre-loaded and dried in the center of each paper microfluidic channel. Human urine samples (undiluted) spiked with E. coli or N. gonorrhoeae were incubated for 5 min with 1% Tween 80. The bacteria-spiked urine samples were then introduced to the inlet of paper microfluidic channel, which flowed through the channel by capillary force. Data confirms that proteins were not filtered by μPAD, which is essential for this assay. Urobilin, the component responsible for the yellow appearance of urine and green fluorescence emission, was filtered by μPAD, resulting in significantly minimized false-positive signals. This filtration was simultaneously made during the μPAD assay and no pretreatment/purification step was necessary. Antibody-conjugated particles were immunoagglutinated at the center of the paper channel. The extent of immunoagglutination was quantified by angle-specific Mie scatter under ambient lighting conditions, utilizing a smartphone camera as a detector. The total μPAD assay time was less than 30s. The detection limit was 10 CFU/mL for both E. coli and N. gonorrhoeae, while commercially available gonorrhea rapid kit showed a detection limit of 10(6) CFU/mL. A commercially available nitrite assay test strip also had a detection limit of 10(6) CFU/mL, but this method is not antibody-based and thus not sufficiently specific. By optimizing the particle concentration, we were also able to extend the linear range of the assay up to 10(7) CFU/mL. The proposed prototype will serve as a low-cost, point-of-care, sensitive urinalysis biosensor to monitor UTI and gonorrhea from human urine. Copyright © 2015 Elsevier B.V. All rights reserved.
Estimating the Rate of Occurrence of Renal Stones in Astronauts
NASA Technical Reports Server (NTRS)
Myers, J.; Goodenow, D.; Gokoglu, S.; Kassemi, M.
2016-01-01
Changes in urine chemistry, during and post flight, potentially increases the risk of renal stones in astronauts. Although much is known about the effects of space flight on urine chemistry, no inflight incidence of renal stones in US astronauts exists and the question "How much does this risk change with space flight?" remains difficult to accurately quantify. In this discussion, we tackle this question utilizing a combination of deterministic and probabilistic modeling that implements the physics behind free stone growth and agglomeration, speciation of urine chemistry and published observations of population renal stone incidences to estimate changes in the rate of renal stone presentation. The modeling process utilizes a Population Balance Equation based model developed in the companion IWS abstract by Kassemi et al. (2016) to evaluate the maximum growth and agglomeration potential from a specified set of urine chemistry values. Changes in renal stone occurrence rates are obtained from this model in a probabilistic simulation that interrogates the range of possible urine chemistries using Monte Carlo techniques. Subsequently, each randomly sampled urine chemistry undergoes speciation analysis using the well-established Joint Expert Speciation System (JESS) code to calculate critical values, such as ionic strength and relative supersaturation. The Kassemi model utilizes this information to predict the mean and maximum stone size. We close the assessment loop by using a transfer function that estimates the rate of stone formation from combining the relative supersaturation and both the mean and maximum free stone growth sizes. The transfer function is established by a simulation analysis which combines population stone formation rates and Poisson regression. Training this transfer function requires using the output of the aforementioned assessment steps with inputs from known non-stone-former and known stone-former urine chemistries. Established in a Monte Carlo system, the entire renal stone analysis model produces a probability distribution of the stone formation rate and an expected uncertainty in the estimate. The utility of this analysis will be demonstrated by showing the change in renal stone occurrence predicted by this method using urine chemistry distributions published in Whitson et al. 2009. A comparison to the model predictions to previous assessments of renal stone risk will be used to illustrate initial validation of the model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yi-Xin; Zeng, Qiang; Wang, Le
Urinary haloacetic acids (HAAs), such as dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA), have been suggested as potential biomarkers of exposure to drinking water disinfection byproducts (DBPs). However, variable exposure to and the short elimination half-lives of these biomarkers can result in considerable variability in urinary measurements, leading to exposure misclassification. Here we examined the variability of DCAA and TCAA levels in the urine among eleven men who provided urine samples on 8 days over 3 months. The urinary concentrations of DCAA and TCAA were measured by gas chromatography coupled with electron capture detection. We calculated the intraclass correlation coefficientsmore » (ICCs) to characterize the within-person and between-person variances and computed the sensitivity and specificity to assess how well single or multiple urine collections accurately determined personal 3-month average DCAA and TCAA levels. The within-person variance was much higher than the between-person variance for all three sample types (spot, first morning, and 24-h urine samples) for DCAA (ICC=0.08–0.37) and TCAA (ICC=0.09–0.23), regardless of the sampling interval. A single-spot urinary sample predicted high (top 33%) 3-month average DCAA and TCAA levels with high specificity (0.79 and 0.78, respectively) but relatively low sensitivity (0.47 and 0.50, respectively). Collecting two or three urine samples from each participant improved the classification. The poor reproducibility of the measured urinary DCAA and TCAA concentrations indicate that a single measurement may not accurately reflect individual long-term exposure. Collection of multiple urine samples from one person is an option for reducing exposure classification errors in studies exploring the effects of DBP exposure on reproductive health. - Highlights: • We evaluated the variability of DCAA and TCAA levels in the urine among men. • Urinary DCAA and TCAA levels varied greatly over a 3-month period. • Single measurement may not accurately reflect personal long-term exposure levels. • Collecting multiple samples from one person improved the exposure classification.« less
Bader, Michael; Messerer, Peter; Will, Wolfgang
2013-08-01
Urinary creatinine is an important parameter for the adjustment of metabolite concentrations in differently diluted urine specimens, as a reference dimension for biological limit or guidance values and as a selection criterion for spot urine samples in human biomonitoring. While the creatinine output of the general population has been well described in environmental surveys, this study focused specifically on creatinine concentrations in a large industrial workforce in order to compare these data with the general population and to provide a database for the calculation of a reasonable conversion factor between volume-related and creatinine-adjusted data and vice versa. Urinary creatinine was analysed in 6,438 spot urine samples by a photometric assay in the time period between 1989 and 2009. Basic demographic data (age, sex, body weight, body height) and job category (apprentices, skilled craftsmen, skilled chemical workers, foremen, laboratory staff and executives) were considered in a statistical analysis. The median concentration of urinary creatinine in all urine samples was 1.36 g/L with male employees showing significantly higher values (1.37 g/L, n = 6,148 samples) than female employees (1.00 g/L, n = 290) and concentrations ranging from 0.01 up to 9.76 g/L. Age, body mass index and job category were significant influence factors on urinary creatinine. About 92 % of all samples showed creatinine concentrations between 0.3 and 3.0 g/L, a range recommended by the World Health Organization as a criterion for valid spot urine samples. The results of this study correspond well with data from environmental surveys and with recent data from an active workforce in industry with similar sampling strategies. Therefore, a median of 1.4 g creatinine per litre urine seems to be a reasonable value for general calculations and adjustments. The study data also support the validity of the current recommendations by the WHO and several scientific committees and institutions with respect to creatinine limits in spot urine samples for occupational-medical biomonitoring.
Peng, Jun; Guo, Kevin; Xia, Jianguo; Zhou, Jianjun; Yang, Jing; Westaway, David; Wishart, David S; Li, Liang
2014-10-03
Because of a limited volume of urine that can be collected from a mouse, it is very difficult to apply the common strategy of using multiple analytical techniques to analyze the metabolites to increase the metabolome coverage for mouse urine metabolomics. We report an enabling method based on differential isotope labeling liquid chromatography mass spectrometry (LC-MS) for relative quantification of over 950 putative metabolites using 20 μL of urine as the starting material. The workflow involves aliquoting 10 μL of an individual urine sample for ¹²C-dansylation labeling that target amines and phenols. Another 10 μL of aliquot was taken from each sample to generate a pooled sample that was subjected to ¹³C-dansylation labeling. The ¹²C-labeled individual sample was mixed with an equal volume of the ¹³C-labeled pooled sample. The mixture was then analyzed by LC-MS to generate information on metabolite concentration differences among different individual samples. The interday repeatability for the LC-MS runs was assessed, and the median relative standard deviation over 4 days was 5.0%. This workflow was then applied to a metabolomic biomarker discovery study using urine samples obtained from the TgCRND8 mouse model of early onset familial Alzheimer's disease (FAD) throughout the course of their pathological deposition of beta amyloid (Aβ). It was showed that there was a distinct metabolomic separation between the AD prone mice and the wild type (control) group. As early as 15-17 weeks of age (presymptomatic), metabolomic differences were observed between the two groups, and after the age of 25 weeks the metabolomic alterations became more pronounced. The metabolomic changes at different ages corroborated well with the phenotype changes in this transgenic mice model. Several useful candidate biomarkers including methionine, desaminotyrosine, taurine, N1-acetylspermidine, and 5-hydroxyindoleacetic acid were identified. Some of them were found in previous metabolomics studies in human cerebrospinal fluid or blood samples. This work illustrates the utility of this isotope labeling LC-MS method for biomarker discovery using mouse urine metabolomics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raml, Reingard; Rumpler, Alice; Goessler, Walter
2007-08-01
Over the last 6 years, much work on arsenic species in urine samples has been directed toward the determination of the reduced dimethylated arsenic species, DMA(III), because of its high toxicity and perceived key role in the metabolism of inorganic arsenic. Recent work, however, has suggested that DMA(III) may at times have been misidentified because its chromatographic properties can be similar to those of thio-dimethylarsinate (thio-DMA). We analyzed by HPLC-ICPMS (inductively coupled plasma mass spectrometry) urine samples from 75 arsenic-exposed women from Bangladesh with total arsenic concentrations ranging from 8 to 1034 {mu}g As/L and found that thio-DMA was presentmore » in 44% of the samples at concentrations ranging mostly from trace amounts to 24 {mu}g As/L (one sample contained 123 {mu}g As/L). Cytotoxicity testing with HepG2 cells derived from human hepatocarcinoma indicated that thio-DMA was about 10-fold more cytotoxic than dimethylarsinate (DMA). The widespread occurrence of thio-DMA in urine from these arsenic-exposed women suggests that this arsenical may also be present in other urine samples and has so far escaped detection. The work highlights the need for analytical methods providing specific determinations of arsenic compounds in future studies on arsenic metabolism and toxicology.« less
Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro
2014-06-10
Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Jiapeng; Huang, Xiaojun; Wang, Qian; Jing, Shan; Jiang, Hao; Wei, Zhongna; Zang, Yannan; Liu, Yang; Zhao, Libo; Fang, Yi; Feng, Wanyu
2015-10-01
Histamine dihydrochloride (HDC) injection has been approved in Europe for the treatment of adults with acute myeloid leukemia, used in combination therapy with the T-cell-derived cytokine interleukin-2. Despite years of clinical applications of HDC in Europe, no data are available on its tolerability and pharmacokinetic properties in Chinese patients. The objective of this study was to determine the safety profile and pharmacokinetic properties of HDC in Chinese healthy volunteers (HVs). In this Phase I, single-center, open-label, randomized study, 20 Chinese HVs were randomized to receive a single dose of 0.5 or 1.0 mg HDC via a 10-minute subcutaneous injection. Whole-blood and urine samples were collected at designated time points after dosing. Plasma and urine concentrations of histamine and metabolite N-methyl histamine were measured using a validated HPLC-MS/MS method. Pharmacokinetic parameters were estimated through noncompartmental procedures based on concentration-time data. Adverse events and evaluation of clinical laboratory tests were used to assess the safety profile. The pharmacokinetic profile for a single-dose of 1.0 mg HDC in Chinese HVs was compared with that in Western HVs. No severe adverse events occurred in this study, and the severity of all adverse events was grade I according to the Common Terminology Criteria for Adverse Events, version 4.0. For the pharmacokinetic parameters of histamine at the 0.5-mg and 1.0-mg dose levels, t½ was 0.50 and 1.02 hours; Tmax was 0.15 and 0.14 hours; mean Cmax was 26.59 and 71.01 nmol/L; AUC0-t was 8.35 and 20.43 nmol/h/L; AUC0-∞ was 9.61 and 22.69 nmol/h/L; accumulated amount excreted in urine within 24 hours was 125.93 and 145.52 nmol; and maximum urine excretion rates were 21.85 and 38.94 nmol/h, respectively. For N-methyl histamine at the 0.5-mg and 1.0-mg dose levels, t½ was 0.58 and 0.66 hours; Tmax was 0.28 and 0.26 hours; mean Cmax was 17.01 and 23.54 nmol/L; AUC0-t was 7.72 and 17.08 nmol/h/L; AUC0-∞ was 9.01 and 19.62 nmol/h/L; accumulated amount excreted in urine within 24 hours was 331.7 and 583.21 nmol; and maximum urine excretion rates were 53.29 and 133.53 nmol/h, respectively. Both single-dose 0.5 mg and 1.0 mg HDC were well tolerated in Chinese HVs, and the pharmacokinetic profile of HDC in Chinese HVs was characterized in this study. A single dose of 1.0 mg HDC had a more rapid but similar extent of absorption, a wider distribution, and a little more rapid elimination in Chinese HVs compared with Western HVs. Findings from this study support additional clinical trials for HDC using in Chinese patients. Chinese Clinical Trial Registry identifier: ChiCTR-ONC-13003954. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.
Saukkoriipi, Annika; Pascal, Thierry; Palmu, Arto A
2016-02-01
We evaluated the BinaxNOW® urine antigen test in elderly. For fresh un-concentrated urine samples, the sensitivity for pneumococcal pneumonia was 63% and specificity 97%. After freezing and concentration, the results comparable to positive control line in intensity at 60 min gave high sensitivity (81%) with no loss in specificity (96%). Copyright © 2015 Elsevier B.V. All rights reserved.