Sample records for ranging ldar system

  1. A preliminary test of the application of the Lightning Detection and Ranging System (LDAR) as a thunderstorm warning and location device for the FHA including a correlation with updrafts, turbulence, and radar precipitation echoes

    NASA Technical Reports Server (NTRS)

    Poehler, H. A.

    1978-01-01

    Results of a test of the use of a Lightning Detection and Ranging (LDAR) remote display in the Patrick AFB RAPCON facility are presented. Agreement between LDAR and radar precipitation echoes of the RAPCON radar was observed, as well as agreement between LDAR and pilot's visual observations of lightning flashes. A more precise comparison between LDAR and KSC based radars is achieved by the superposition of LDAR precipitation echoes. Airborne measurements of updrafts and turbulence by an armored T-28 aircraft flying through the thunderclouds are correlated with LDAR along the flight path. Calibration and measurements of the accuracy of the LDAR System are discussed, and the extended range of the system is illustrated.

  2. Measured electric field intensities near electric cloud discharges detected by the Kennedy Space Center's Lightning Detection and Ranging System, LDAR

    NASA Technical Reports Server (NTRS)

    Poehler, H. A.

    1977-01-01

    For a summer thunderstorm, for which simultaneous, airborne electric field measurements and Lightning Detection and Ranging (LDAR) System data was available, measurements were coordinated to present a picture of the electric field intensity near cloud electrical discharges detected by the LDAR System. Radar precipitation echos from NOAA's 10 cm weather radar and measured airborne electric field intensities were superimposed on LDAR PPI plots to present a coordinated data picture of thunderstorm activity.

  3. Lightning studies using LDAR and LLP data

    NASA Technical Reports Server (NTRS)

    Forbes, Gregory S.

    1993-01-01

    This study intercompared lightning data from LDAR and LLP systems in order to learn more about the spatial relationships between thunderstorm electrical discharges aloft and lightning strikes to the surface. The ultimate goal of the study is to provide information that can be used to improve the process of real-time detection and warning of lightning by weather forecasters who issue lightning advisories. The Lightning Detection and Ranging (LDAR) System provides data on electrical discharges from thunderstorms that includes cloud-ground flashes as well as lightning aloft (within cloud, cloud-to-cloud, and sometimes emanating from cloud to clear air outside or above cloud). The Lightning Location and Protection (LLP) system detects primarily ground strikes from lightning. Thunderstorms typically produce LDAR signals aloft prior to the first ground strike, so that knowledge of preferred positions of ground strikes relative to the LDAR data pattern from a thunderstorm could allow advance estimates of enhanced ground strike threat. Studies described in the report examine the position of LLP-detected ground strikes relative to the LDAR data pattern from the thunderstorms. The report also describes other potential approaches to the use of LDAR data in the detection and forecasting of lightning ground strikes.

  4. Lightning studies using LDAR and companion data sets

    NASA Technical Reports Server (NTRS)

    Forbes, Gregory S.

    1994-01-01

    Research was conducted to use the KSC Lightning Detection and Ranging (LDAR) system, together with companion data, in four subprojects: weather forecasting and advisory applications of LDAR, LDAR in relation to field mill readings, lightning flash and stroke detection using LDAR, and LDAR in relation to radar reflectivity patterns and KSC wind profiler vertical velocities. The research is aimed at developing rules, algorithms, and training materials that can be used by the operational weather forecasters who issue weather advisories for daily ground operations and launches by NASA and the United States Air Force. During the summer of 1993, LDAR data was examined on an hourly basis from 14 thunderstorm days and compared to ground strike data measured by the Lightning Location and Protection (LLP) system. These data were re-examined during 1994 to identify, number, and track LDAR-detected storms continually throughout the day and avoid certain interpretation problems arising from the use of hourly files. An areal storm growth factor was incorporated into a scheme to use current mappings of LDAR-defined thunderstorms to predict future ground strikes. During the summer of 1994, extensive sets of LDAR and companion data have been collected for 16 thunderstorm days, including a variety of meteorological situations. Detailed case studies are being conducted to relate the occurence of LDAR to the radar structure and evolution of thunderstorms. Field mill (LPWS) data are being examined to evaluate the complementary nature of LDAR and LPLWS data in determining the time of beginning and ending of the ground strike threat at critical sites. A computerized lightning flash and stroke discrimination algorithm has been written that can be used to help locate the points of origin of the electrical discharges, help distinguish in-cloud, cloud-ground, and upward flashes, and perhaps determine when the threat of ground strikes has ceased. Surface wind tower (mesonet), radar, sounding, and KSC wind profiler data will be used to develop schemes to help anticipate the timing and location of new thunderstorm development. Analysis of this data will continue in graduate student research projects.

  5. LDAR, A Three-Dimensional Lightning Warning System: Its Development and Use by the Government, and Transition to Public Availability

    NASA Technical Reports Server (NTRS)

    Starr, Stan; Sharp, David; Merceret, Francis; Madura, John; Murphy, Martin

    1998-01-01

    NASA, at the John F. Kennedy Space Center (KSC), developed and operates a unique high precision lightning location system to provide lightning related weather warnings. These warnings are used to stop lightning-sensitive operations such as space vehicle launches and ground operations where equipment and personnel are at risk. The data is provided to the Range Weather Operations [45th Weather Squadron, U. S. Air Force (USAF)] where it is used with other meteorological data to issue weather advisories and warnings for Cape Canaveral Air Station (CCAS) and KSC operations. This system, called Lightning Detection and Ranging (LDAR), provides users with a graphical display in three dimensions of 66 MHz radio frequency events generated by lightning processes. The locations of these events provide a sound basis for the prediction of lightning hazards. NASA and Global Atmospherics, Inc. are developing a new system that will replace the unique LDAR components with commercially available and maintainable components having improved capabilities. These components will be phased in to ensure full continuity and access to this important warning technology. These LDAR systems are expected to eventually be available for installation and use by the public at specialized facilities, such as airports, and for general weather warnings via the National Weather Service (NWS) or television broadcast. The NWS in Melbourne has had access to real-time LDAR data since 1993 on an experimental basis. This use of LDAR has shown promise for the improvement of aviation forecasts and severe weather warnings. More so, it has opened the door to investigate the feasibility of issuing lightning-related public advisories. The success of its early use suggests that this technology may improve safety and potentially save lives, therefore constituting a significant benefit to the public. This paper describes the LDR system, the plans and progress of these upgrades, and the potential benefits of its use.

  6. Development of Algorithms and Error Analyses for the Short Baseline Lightning Detection and Ranging System

    NASA Technical Reports Server (NTRS)

    Starr, Stanley O.

    1998-01-01

    NASA, at the John F. Kennedy Space Center (KSC), developed and operates a unique high-precision lightning location system to provide lightning-related weather warnings. These warnings are used to stop lightning- sensitive operations such as space vehicle launches and ground operations where equipment and personnel are at risk. The data is provided to the Range Weather Operations (45th Weather Squadron, U.S. Air Force) where it is used with other meteorological data to issue weather advisories and warnings for Cape Canaveral Air Station and KSC operations. This system, called Lightning Detection and Ranging (LDAR), provides users with a graphical display in three dimensions of 66 megahertz radio frequency events generated by lightning processes. The locations of these events provide a sound basis for the prediction of lightning hazards. This document provides the basis for the design approach and data analysis for a system of radio frequency receivers to provide azimuth and elevation data for lightning pulses detected simultaneously by the LDAR system. The intent is for this direction-finding system to correct and augment the data provided by LDAR and, thereby, increase the rate of valid data and to correct or discard any invalid data. This document develops the necessary equations and algorithms, identifies sources of systematic errors and means to correct them, and analyzes the algorithms for random error. This data analysis approach is not found in the existing literature and was developed to facilitate the operation of this Short Baseline LDAR (SBLDAR). These algorithms may also be useful for other direction-finding systems using radio pulses or ultrasonic pulse data.

  7. A LIS Validation Study at the KSC-ER using LDAR and Field Mill Data

    NASA Technical Reports Server (NTRS)

    Koshak, William J.; Christian, Hugh J.; Krider, E. Philip

    1999-01-01

    The chance of having the TRMM satellite pass over east central Florida when there is lightning over the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER) is small; however, such a condition did occur on September 21, 1998 (Day 264). Starting at about 20:40 GMT, the Lightning Imaging Sensor (LIS) reported 5 flashes during a 90 second interval that the KSC-ER was within the sensor field of view. Ground-based instrumentation, the Lightning Detection and Ranging (LDAR) system and a network of electric field mills (FM), detected 6 flashes in the same interval. In this paper, we will compare the times and locations of the optical pulses that were detected by LIS with the times and locations of RF sources (LDAR) and the charges that were deposited by the flash (FM network). We will show that LIS responded to all flashes that the LDAR and FM network detected; however, two discharges that were separated by less than 1 second in time and by about 10 km in space were grouped as one flash by the LIS data processing algorithm. In spite of the fact that all flashes occurred near the edge of the LIS field of view, the locations of the LIS events were consistent with both the LDAR and FM locations (the latter are usually within 1-2 kilometers of each other and often are co-located). Two of the 5 flashes reported by LIS were shifted north by about 8 km from the corresponding LDAR and FM locations. The LIS flash times tended to be after the first LDAR pulse was detected and before the last, and the integrated light signal (per LIS event) was surprisingly constant over the 5 flashes that were detected by LIS. In the future, we plan to study more correlated events and will try to determine whether and how the LIS light signal is related to the charge transfer in the flash and/or the number and spatial extent of RF sources.

  8. Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison w/ LIS Satellite Data

    NASA Technical Reports Server (NTRS)

    Koshak, William; Krider, E. Philip; Murray, Natalie; Boccippio, Dennis

    2007-01-01

    A "dimensional reduction" (DR) method is introduced for analyzing lightning field changes whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight to just four. The four unknowns are found by performing a numerical minimization of a chi-squared goodness-of-fit function. At each step of the minimization, an Overdetermined Fixed Matrix (OFM) method is used to immediately retrieve the best "residual source". In this way, all 8 parameters are found, yet a numerical search of only 4 parameters is required. The inversion method is applied to the understanding of lightning charge retrievals. The accuracy of the DR method has been assessed by comparing retrievals with data provided by the Lightning Detection And Ranging (LDAR) instrument. Because lightning effectively deposits charge within thundercloud charge centers and because LDAR traces the geometrical development of the lightning channel with high precision, the LDAR data provides an ideal constraint for finding the best model charge solutions. In particular, LDAR data can be used to help determine both the horizontal and vertical positions of the model charges, thereby eliminating dipole ambiguities. The results of the LDAR-constrained charge retrieval method have been compared to the locations of optical pulses/flash locations detected by the Lightning Imaging Sensor (LIS).

  9. Impact of Methane Leak Detection and Repair Programs: Determining Pre- and Post-Survey Emissions Profiles

    NASA Astrophysics Data System (ADS)

    Roda-Stuart, D. J.; Ravikumar, A. P.; Brandt, A. R.

    2017-12-01

    Upstream production sites contribute 66 percent of methane emissions from natural gas systems [1]. Being a major greenhouse gas, many states and national governments are developing policies to reduce methane emissions. Recent policies to address this issue have focused on periodic leak detection and repair (LDAR) surveys at oil and gas facilities [2]. Development of effective LDAR surveys is complicated by two things. First, available empirical data makes it difficult to say anything definitive about which facilities or equipment are most prone to leakage. Second, there has been little research done on post-LDAR emissions profiles and the time evolution of leaks, two measures that would influence survey effectiveness and cost. In this work, we present data from LDAR operations conducted at upstream facilities of a Canadian natural gas producer. Surveys were done by an outside contractor using a FLIR optical gas imaging camera. Twenty-two well pads, five processing plants, and three compressor stations were surveyed, of which four, two, and one, respectively, were revisited. We examine the persistence of leaks over time periods ranging from 6 months to 15 months following the initial LDAR survey. Developing pre- and post-survey emission factors and distributions can help inform survey schedules and help update and monitor mitigation targets. Furthermore, we analyze the effect of weather conditions, survey frequency, and operational characteristics of equipment on the effectiveness of the LDAR program. For instance, we find that a survey done at the commissioning of a gas processing plant yields both safety and emissions reduction benefits. Using leak frequency distributions, we identify components and equipment that require more frequent and targeted surveying. Insights from this study can assist businesses and policy makers develop methane mitigation policies aimed at maximizing the marginal benefits of LDAR programs. [1] Inventory of U.S. Greenhouse Gas Emissions and Sinks: 1990-2015. US Environmental Protection Agency, 2017. [2] New Source Performance Standards; Oil and Natural Gas Sector: Emission Standards for New, Reconstructed, and Modified Sources. Federal Register, 81(107):35824-35942, 2016.

  10. The winter gap effect in methane leak detection and repair with optical gas imaging cameras

    NASA Astrophysics Data System (ADS)

    Fox, T. A.; Barchyn, T.; Hugenholtz, C.

    2017-12-01

    Implementing effective leak detection and repair (LDAR) programs is essential for mitigating fugitive methane emissions from oil and gas operations. In Canada, newly proposed regulations will require that high-risk facilities be surveyed 3 times/yr for fugitive leaks. Like the United States, Canada promotes the use of Optical Gas Imaging cameras (OGIs) for detecting natural gas leaks during LDAR surveys. However, recent research suggests OGIs may perform poorly under adverse environmental conditions, especially in low temperatures. For regions like Canada that experience cold winters, OGIs may not be reliably used for months at a time, meaning that leaks may accumulate and emit for longer periods before being repaired. While considerable oil and gas activity occurs in high-latitude regions with cold winters, no research has explored how extended cold periods impact OGI-focused LDAR programs. To improve this understanding, we present a simple model exploring relationships among winter gap length, fugitive methane emissions, and investment input for LDAR programs employing OGI instruments in gas producing regions of different latitudes. Preliminary results suggest that longer gaps between LDAR surveys caused by cold temperatures result in either 1) higher total emissions for the year, or 2) greater time and equipment investment in LDAR programs to achieve emissions mitigation equivalent to LDAR programs operating under ideal conditions. When weather constraints are removed and LDAR surveys are evenly spaced throughout the year, emissions mitigation is optimized. However, as the winter gap duration and the size of the implicated area increases, fugitive leaks last longer. Furthermore, a spillover effect is observed as LDAR crews become overwhelmed with the high volume of work required as temperatures increase in the spring. Our model adds weight to the argument that LDAR programs should be tailored to regional needs, and that regulators should be more cognisant of sensor-specific limitations as they develop LDAR protocols.

  11. Lightning forecasting studies using LDAR, LLP, field mill, surface mesonet, and Doppler radar data

    NASA Technical Reports Server (NTRS)

    Forbes, Gregory S.; Hoffert, Steven G.

    1995-01-01

    The ultimate goal of this research is to develop rules, algorithms, display software, and training materials that can be used by the operational forecasters who issue weather advisories for daily ground operations and launches by NASA and the United States Air Force to improve real-time forecasts of lightning. Doppler radar, Lightning Detection and Ranging (LDAR), Lightning Location and Protection (LLP), field mill (Launch Pad Lightning Warning System -- LPLWS), wind tower (surface mesonet) and additional data sets have been utilized in 10 case studies of thunderstorms in the vicinity of KSC during the summers of 1994 and 1995. These case studies reveal many intriguing aspects of cloud-to-ground, cloud-to-cloud, in-cloud, and cloud-to-air lightning discharges in relation to radar thunderstorm structure and evolution. They also enable the formulation of some preliminary working rules of potential use in the forecasting of initial and final ground strike threat. In addition, LDAR and LLP data sets from 1993 have been used to quantify the lightning threat relative to the center and edges of LDAR discharge patterns. Software has been written to overlay and display the various data sets as color imagery. However, human intervention is required to configure the data sets for proper intercomparison. Future efforts will involve additional software development to automate the data set intercomparisons, to display multiple overlay combinations in a windows format, and to allow for animation of the imagery. The software package will then be used as a tool to examine more fully the current cases and to explore additional cases in a timely manner. This will enable the formulation of more general and reliable forecasting guidelines and rules.

  12. Lightning Detection and Ranging system LDAR system description and performance objectives

    NASA Technical Reports Server (NTRS)

    Poehler, H. A.; Lennon, C. L.

    1979-01-01

    The instruments used at the six remote stations to measure both the time-of-arrival of the envelope of the pulsed 60 MHz to 80 MHz portion of the RF signal emitted by lightning, and the electric field waveforms are described as well as the two methods of transmitting the signal to the central station. Other topics discussed include data processing, recording, and reduction techniques and the software used for the 2100S, 2114, and 2116 computers.

  13. Efficient Processing of Data for Locating Lightning Strikes

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J.; Starr, Stan

    2003-01-01

    Two algorithms have been devised to increase the efficiency of processing of data in lightning detection and ranging (LDAR) systems so as to enable the accurate location of lightning strikes in real time. In LDAR, the location of a lightning strike is calculated by solving equations for the differences among the times of arrival (DTOAs) of the lightning signals at multiple antennas as functions of the locations of the antennas and the speed of light. The most difficult part of the problem is computing the DTOAs from digitized versions of the signals received by the various antennas. One way (a time-domain approach) to determine the DTOAs is to compute cross-correlations among variously differentially delayed replicas of the digitized signals and to select, as the DTOAs, those differential delays that yield the maximum correlations. Another way (a frequency-domain approach) to determine the DTOAs involves the computation of cross-correlations among Fourier transforms of variously differentially phased replicas of the digitized signals, along with utilization of the relationship among phase difference, time delay, and frequency.

  14. Escape from Lethal Bacterial Competition through Coupled Activation of Antibiotic Resistance and a Mobilized Subpopulation

    PubMed Central

    Stubbendieck, Reed M.; Straight, Paul D.

    2015-01-01

    Bacteria have diverse mechanisms for competition that include biosynthesis of extracellular enzymes and antibiotic metabolites, as well as changes in community physiology, such as biofilm formation or motility. Considered collectively, networks of competitive functions for any organism determine success or failure in competition. How bacteria integrate different mechanisms to optimize competitive fitness is not well studied. Here we study a model competitive interaction between two soil bacteria: Bacillus subtilis and Streptomyces sp. Mg1 (S. Mg1). On an agar surface, colonies of B. subtilis suffer cellular lysis and progressive degradation caused by S. Mg1 cultured at a distance. We identify the lytic and degradative activity (LDA) as linearmycins, which are produced by S. Mg1 and are sufficient to cause lysis of B. subtilis. We obtained B. subtilis mutants spontaneously resistant to LDA (LDAR) that have visibly distinctive morphology and spread across the agar surface. Every LDAR mutant identified had a missense mutation in yfiJK, which encodes a previously uncharacterized two-component signaling system. We confirmed that gain-of-function alleles in yfiJK cause a combination of LDAR, changes in colony morphology, and motility. Downstream of yfiJK are the yfiLMN genes, which encode an ATP-binding cassette transporter. We show that yfiLMN genes are necessary for LDA resistance. The developmental phenotypes of LDAR mutants are genetically separable from LDA resistance, suggesting that the two competitive functions are distinct, but regulated by a single two-component system. Our findings suggest that a subpopulation of B. subtilis activate an array of defensive responses to counter lytic stress imposed by competition. Coordinated regulation of development and antibiotic resistance is a streamlined mechanism to promote competitive fitness of bacteria. PMID:26647299

  15. Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison with LIS Satellite Data

    NASA Technical Reports Server (NTRS)

    Koshak, W. J.; Krider, E. P.; Murray, N.; Boccippio, D. J.

    2007-01-01

    A "dimensional reduction" (DR) method is introduced for analyzing lightning field changes (DELTAEs) whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight (x, y, z, Q, x', y', z', Q') to just four (x, y, z, Q). The four unknowns (x, y, z, Q) are found by performing a numerical minimization of a chi-square function. At each step of the minimization, an Overdetermined Fixed Matrix (OFM) method is used to immediately retrieve the best "residual source" (x', y', z', Q'), given the values of (x, y, z, Q). In this way, all 8 parameters (x, y, z, Q, x', y', z', Q') are found, yet a numerical search of only 4 parameters (x, y, z, Q) is required. The DR method has been used to analyze lightning-caused DeltaEs derived from multiple ground-based electric field measurements at the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER). The accuracy of the DR method has been assessed by comparing retrievals with data provided by the Lightning Detection And Ranging (LDAR) system at the KSC-ER, and from least squares error estimation theory, and the method is shown to be a useful "stand-alone" charge retrieval tool. Since more than one charge distribution describes a finite set of DELTAEs (i.e., solutions are non-unique), and since there can exist appreciable differences in the physical characteristics of these solutions, not all DR solutions are physically acceptable. Hence, an alternative and more accurate method of analysis is introduced that uses LDAR data to constrain the geometry of the charge solutions, thereby removing physically unacceptable retrievals. The charge solutions derived from this method are shown to compare well with independent satellite- and ground-based observations of lightning in several Florida storms.

  16. Lightning electromagnetics

    NASA Technical Reports Server (NTRS)

    Wahid, Parveen

    1995-01-01

    This project involved the determination of the effective radiated power of lightning sources and the polarization of the radiating source. This requires the computation of the antenna patterns at all the LDAR site receiving antennas. The known radiation patterns and RF signal levels measured at the antennas will be used to determine the effective radiated power of the lightning source. The azimuth and elevation patterns of the antennas in the LDAR system were computed using flight test data that was gathered specifically for this purpose. The results presented in this report deal with the azimuth patterns for all the antennas and the elevation patterns for three of the seven sites.

  17. Test/QA Plan for Verification of Leak Detection and Repair Technologies

    EPA Science Inventory

    The purpose of the leak detection and repair (LDAR) test and quality assurance plan is to specify procedures for a verification test applicable to commercial LDAR technologies. The purpose of the verification test is to evaluate the performance of participating technologies in b...

  18. Development of a novel optical remote sensing monitor for fenceline monitoring and enhancement of existing leak detection and repair programs

    EPA Science Inventory

    Manual leak detection and repair (LDAR) programs are currently implemented on a regular basis at refinery sites to limit fugitive emissions of volatile organic compounds (VOC). However, LDAR surveys can be time-consuming and are not always cost-effective. Fence line monitoring of...

  19. 76 FR 46842 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-03

    ..., Section 301(a) of the Clean Water Act, 42 U.S.C. 1311(a), and Section 3005(a) of the Resource Conservation..., Michigan. Under the Consent Decree, Dow will implement an Enhanced Leak Detection and Repair (``LDAR'') Program which imposes leak monitoring and repair requirements more stringent than existing LDAR...

  20. Future Expansion of the Lightning Surveillance System at the Kennedy Space Center and the Cape Canaveral Air Force Station, Florida, USA

    NASA Technical Reports Server (NTRS)

    Mata, C. T.; Wilson, J. G.

    2012-01-01

    The NASA Kennedy Space Center (KSC) and the Air Force Eastern Range (ER) use data from two cloud-to-ground (CG) lightning detection networks, the Cloud-to-Ground Lightning Surveillance System (CGLSS) and the U.S. National Lightning Detection Network (NLDN), and a volumetric mapping array, the lightning detection and ranging II (LDAR II) system: These systems are used to monitor and characterize lightning that is potentially hazardous to launch or ground operations and hardware. These systems are not perfect and both have documented missed lightning events when compared to the existing lightning surveillance system at Launch Complex 39B (LC39B). Because of this finding it is NASA's plan to install a lightning surveillance system around each of the active launch pads sharing site locations and triggering capabilities when possible. This paper shows how the existing lightning surveillance system at LC39B has performed in 2011 as well as the plan for the expansion around all active pads.

  1. Development of cost effective fenceline monitoring approaches to support advanced leak detection and repair strategies

    EPA Science Inventory

    Cost-effective fence line and process monitoring systems to support advanced leak detection and repair (LDAR) strategies can enhance protection of public health, facilitate worker safety, and help companies realize cost savings by reducing lost product. The U.S. EPA Office of Re...

  2. Refinery evaluation of optical imaging to locate fugitive emissions.

    PubMed

    Robinson, Donald R; Luke-Boone, Ronke; Aggarwal, Vineet; Harris, Buzz; Anderson, Eric; Ranum, David; Kulp, Thomas J; Armstrong, Karla; Sommers, Ricky; McRae, Thomas G; Ritter, Karin; Siegell, Jeffrey H; Van Pelt, Doug; Smylie, Mike

    2007-07-01

    Fugitive emissions account for approximately 50% of total hydrocarbon emissions from process plants. Federal and state regulations aiming at controlling these emissions require refineries and petrochemical plants in the United States to implement a Leak Detection and Repair Program (LDAR). The current regulatory work practice, U.S. Environment Protection Agency Method 21, requires designated components to be monitored individually at regular intervals. The annual costs of these LDAR programs in a typical refinery can exceed US$1,000,000. Previous studies have shown that a majority of controllable fugitive emissions come from a very small fraction of components. The Smart LDAR program aims to find cost-effective methods to monitor and reduce emissions from these large leakers. Optical gas imaging has been identified as one such technology that can help achieve this objective. This paper discusses a refinery evaluation of an instrument based on backscatter absorption gas imaging technology. This portable camera allows an operator to scan components more quickly and image gas leaks in real time. During the evaluation, the instrument was able to identify leaking components that were the source of 97% of the total mass emissions from leaks detected. More than 27,000 components were monitored. This was achieved in far less time than it would have taken using Method 21. In addition, the instrument was able to find leaks from components that are not required to be monitored by the current LDAR regulations. The technology principles and the parameters that affect instrument performance are also discussed in the paper.

  3. Characterizing the Relationships Among Lightning and Storm Parameters: Lightning as a Proxy Variable

    NASA Technical Reports Server (NTRS)

    Goodman, S. J.; Raghavan, R.; William, E.; Weber, M.; Boldi, B.; Matlin, A.; Wolfson, M.; Hodanish, S.; Sharp. D.

    1997-01-01

    We have gained important insights from prior studies that have suggested relationships between lightning and storm growth, decay, convective rain flux, vertical distribution of storm mass and echo volume in the region, and storm energetics. A study was initiated in the Summer of 1996 to determine how total (in-cloud plus ground) lightning observations might provide added knowledge to the forecaster in the determination and identification of severe thunderstorms and weather hazards in real-time. The Melbourne Weather Office was selected as a primary site to conduct this study because Melbourne is the only site in the world with continuous and open access to total lightning (LDAR) data and a Doppler (WSR-88D) radar. A Lightning Imaging Sensor Data Applications Demonstration (LISDAD) system was integrated into the forecaster's workstation during the Summer 1996 to allow the forecaster to interact in real-time with the multi-sensor data being displayed. LISDAD currently ingests LDAR data, the cloud-to-ground National Lightning Detection Network (NLDN) data, and the Melbourne radar data in f real-time. The interactive features provide the duty forecaster the ability to perform quick diagnostics on storm cells of interest. Upon selection of a storm cell, a pop-up box appears displaying the time-history of various storm parameters (e.g., maximum radar reflectivity, height of maximum reflectivity, echo-top height, NLDN and LDAR lightning flash rates, storm-based vertically integrated liquid water content). This product is archived to aid on detailed post-analysis.

  4. Developing Empirical Lightning Cessation Forecast Guidance for the Cape Canaveral Air Force Station and Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Stano, Geoffrey T.; Fuelberg, Henry E.; Roeder, William P.

    2010-01-01

    This research addresses the 45th Weather Squadron's (45WS) need for improved guidance regarding lightning cessation at Cape Canaveral Air Force Station and Kennedy Space Center (KSC). KSC's Lightning Detection and Ranging (LDAR) network was the primary observational tool to investigate both cloud-to-ground and intracloud lightning. Five statistical and empirical schemes were created from LDAR, sounding, and radar parameters derived from 116 storms. Four of the five schemes were unsuitable for operational use since lightning advisories would be canceled prematurely, leading to safety risks to personnel. These include a correlation and regression tree analysis, three variants of multiple linear regression, event time trending, and the time delay between the greatest height of the maximum dBZ value to the last flash. These schemes failed to adequately forecast the maximum interval, the greatest time between any two flashes in the storm. The majority of storms had a maximum interval less than 10 min, which biased the schemes toward small values. Success was achieved with the percentile method (PM) by separating the maximum interval into percentiles for the 100 dependent storms.

  5. A Lightning Channel Retrieval Algorithm for the North Alabama Lightning Mapping Array (LMA)

    NASA Technical Reports Server (NTRS)

    Koshak, William; Arnold, James E. (Technical Monitor)

    2002-01-01

    A new multi-station VHF time-of-arrival (TOA) antenna network is, at the time of this writing, coming on-line in Northern Alabama. The network, called the Lightning Mapping Array (LMA), employs GPS timing and detects VHF radiation from discrete segments (effectively point emitters) that comprise the channel of lightning strokes within cloud and ground flashes. The network will support on-going ground validation activities of the low Earth orbiting Lightning Imaging Sensor (LIS) satellite developed at NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama. It will also provide for many interesting and detailed studies of the distribution and evolution of thunderstorms and lightning in the Tennessee Valley, and will offer many interesting comparisons with other meteorological/geophysical wets associated with lightning and thunderstorms. In order to take full advantage of these benefits, it is essential that the LMA channel mapping accuracy (in both space and time) be fully characterized and optimized. In this study, a new revised channel mapping retrieval algorithm is introduced. The algorithm is an extension of earlier work provided in Koshak and Solakiewicz (1996) in the analysis of the NASA Kennedy Space Center (KSC) Lightning Detection and Ranging (LDAR) system. As in the 1996 study, direct algebraic solutions are obtained by inverting a simple linear system of equations, thereby making computer searches through a multi-dimensional parameter domain of a Chi-Squared function unnecessary. However, the new algorithm is developed completely in spherical Earth-centered coordinates (longitude, latitude, altitude), rather than in the (x, y, z) cartesian coordinates employed in the 1996 study. Hence, no mathematical transformations from (x, y, z) into spherical coordinates are required (such transformations involve more numerical error propagation, more computer program coding, and slightly more CPU computing time). The new algorithm also has a more realistic definition of source altitude that accounts for Earth oblateness (this can become important for sources that are hundreds of kilometers away from the network). In addition, the new algorithm is being applied to analyze computer simulated LMA datasets in order to obtain detailed location/time retrieval error maps for sources in and around the LMA network. These maps will provide a more comprehensive analysis of retrieval errors for LMA than the 1996 study did of LDAR retrieval errors. Finally, we note that the new algorithm can be applied to LDAR, and essentially any other multi-station TWA network that depends on direct line-of-site antenna excitation.

  6. Of Detection Limits and Effective Mitigation: The Use of Infrared Cameras for Methane Leak Detection

    NASA Astrophysics Data System (ADS)

    Ravikumar, A. P.; Wang, J.; McGuire, M.; Bell, C.; Brandt, A. R.

    2017-12-01

    Mitigating methane emissions, a short-lived and potent greenhouse gas, is critical to limiting global temperature rise to two degree Celsius as outlined in the Paris Agreement. A major source of anthropogenic methane emissions in the United States is the oil and gas sector. To this effect, state and federal governments have recommended the use of optical gas imaging systems in periodic leak detection and repair (LDAR) surveys to detect for fugitive emissions or leaks. The most commonly used optical gas imaging systems (OGI) are infrared cameras. In this work, we systematically evaluate the limits of infrared (IR) camera based OGI system for use in methane leak detection programs. We analyze the effect of various parameters that influence the minimum detectable leak rates of infrared cameras. Blind leak detection tests were carried out at the Department of Energy's MONITOR natural gas test-facility in Fort Collins, CO. Leak sources included natural gas wellheads, separators, and tanks. With an EPA mandated 60 g/hr leak detection threshold for IR cameras, we test leak rates ranging from 4 g/hr to over 350 g/hr at imaging distances between 5 ft and 70 ft from the leak source. We perform these experiments over the course of a week, encompassing a wide range of wind and weather conditions. Using repeated measurements at a given leak rate and imaging distance, we generate detection probability curves as a function of leak-size for various imaging distances, and measurement conditions. In addition, we estimate the median detection threshold - leak-size at which the probability of detection is 50% - under various scenarios to reduce uncertainty in mitigation effectiveness. Preliminary analysis shows that the median detection threshold varies from 3 g/hr at an imaging distance of 5 ft to over 150 g/hr at 50 ft (ambient temperature: 80 F, winds < 4 m/s). Results from this study can be directly used to improve OGI based LDAR protocols and reduce uncertainty in estimated mitigation effectiveness. Furthermore, detection limits determined in this study can be used as standards to compare new detection technologies.

  7. Is Optical Gas Imaging Effective for Detecting Fugitive Methane Emissions? - A Technological and Policy Perspective

    NASA Astrophysics Data System (ADS)

    Ravikumar, A. P.; Wang, J.; Brandt, A. R.

    2016-12-01

    Mitigating fugitive methane emissions from the oil and gas industry has become an important concern for both businesses and regulators. While recent studies have improved our understanding of emissions from all sectors of the natural gas supply chain, cost-effectively identifying leaks over expansive natural gas infrastructure remains a significant challenge. Recently, the Environmental Protection Agency (EPA) has recommended the use of optical gas imaging (OGI) technologies to be used in industry-wide leak detection and repair (LDAR) programs. However, there has been little to no systematic study of the effectiveness of infrared-camera-based OGI technology for leak detection applications. Here, we develop a physics-based model that simulates a passive infrared camera imaging a methane leak against varying background and ambient conditions. We verify the simulation tool through a series of large-volume controlled release field experiments wherein known quantities of methane were released and imaged from a range of distances. After simulator verification, we analyze the effects of environmental conditions like temperature, wind, and imaging background on the amount of methane detected from a statistically representative survey program. We also examine the effects of LDAR design parameters like imaging distance, leak size distribution, and gas composition. We show that imaging distance strongly affects leak detection - EPA's expectation of a 60% reduction in fugitive emissions based on a semi-annual LDAR survey will be realized only if leaks are imaged at a distance less than 10 m from the source under ideal environmental conditions. Local wind speed is also shown to be important. We show that minimum detection limits are 3 to 4 times higher for wet-gas compositions that contain a significant fraction of ethane and propane, resulting a significantly large leakage rate. We also explore the importance of `super-emitters' on the performance of an OGI-based leak detection program, and show that OGI technology can be used as an approximate leak-quantification method to selectively target the biggest leaks. Finally, we also provide recommendations and best-practices guidelines for achieving expected methane mitigation.

  8. Classification of Small Negative Lightning Reports at the KSC-ER

    NASA Technical Reports Server (NTRS)

    Ward, Jennifer G.; Cummins, Kenneth L.; Krider, Philip

    2008-01-01

    The NASA Kennedy Space Center (KSC) and Air Force Eastern Range (ER) operate an extensive suite of lightning sensors because Florida experiences the highest area density of ground strikes in the United States, with area densities approaching 16 fl/sq km/yr when accumulated in 10x10 km (100 sq km) grids. The KSC-ER use data derived from two cloud-to-ground (CG) lightning detection networks, the "Cloud-to-Ground Lightning Surveillance System" (CGLSS) and the U.S. National Lightning Detection Network (TradeMark) (NLDN) plus a 3-dimensional lightning mapping system, the Lightning Detection and Ranging (LDAR) system, to provide warnings for ground operations and to insure mission safety during space launches. For operational applications at the KSC-ER it is important to understand the performance of each lightning detection system in considerable detail. In this work we examine a specific subset of the CGLSS stroke reports that have low values of the negative inferred peak current, Ip, i.e. values between 0 and -7 kA, and were thought to produce a new ground contact (NGC). When possible, the NLDN and LDAR systems were used to validate the CGLSS classification and to determine how many of these reported strokes were first strokes, subsequent strokes in a pre-existing channel (PEC), or cloud pulses that the CGLSS misclassified as CG strokes. It is scientifically important to determine the smallest current that can reach the ground either in the form of a first stroke or by way of a subsequent stroke that creates a new ground contact. In Biagi et al (2007), 52 low amplitude, negative return strokes ([Ip] < or = 10 kA) were evaluated in southern Arizona, northern Texas, and southern Oklahoma. The authors found that 50-87% of the small NLDN reports could be classified as CG (either first or subsequent strokes) on the basis of video and waveform recordings. Low amplitude return strokes are interesting because they are usually difficult to detect, and they are thought to bypass conventional lightning protection that relies on a sufficient attractive radius to prevent "shielding failure" (Golde, 1977). They also have larger location errors compared to the larger current events. In this study, we use the estimated peak current provided by the CGLSS and the results of our classification to determine the minimum Ip for each category of CG stroke and its probability of occurrence. Where possible, these results are compared to the findings in the literature.

  9. 76 FR 39899 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-07

    ... emissions of nitrogen oxides, sulfur dioxide, volatile organic compounds, and benzene. Among other things... refinery's benzene monitoring program is enhanced, and the refinery's leak-detection-and-repair (LDAR...

  10. Small negative cloud-to-ground lightning reports at the NASA Kennedy Space Center and Air Force Eastern Range

    NASA Astrophysics Data System (ADS)

    Wilson, Jennifer G.; Cummins, Kenneth L.; Krider, E. Philip

    2009-12-01

    The NASA Kennedy Space Center (KSC) and Air Force Eastern Range (ER) use data from two cloud-to-ground (CG) lightning detection networks, the Cloud-to-Ground Lightning Surveillance System (CGLSS) and the U.S. National Lightning Detection Network™ (NLDN), and a volumetric lightning mapping array, the Lightning Detection and Ranging (LDAR) system, to monitor and characterize lightning that is potentially hazardous to launch or ground operations. Data obtained from these systems during June-August 2006 have been examined to check the classification of small, negative CGLSS reports that have an estimated peak current, ∣Ip∣ less than 7 kA, and to determine the smallest values of Ip that are produced by first strokes, by subsequent strokes that create a new ground contact (NGC), and by subsequent strokes that remain in a preexisting channel (PEC). The results show that within 20 km of the KSC-ER, 21% of the low-amplitude negative CGLSS reports were produced by first strokes, with a minimum Ip of -2.9 kA; 31% were by NGCs, with a minimum Ip of -2.0 kA; and 14% were by PECs, with a minimum Ip of -2.2 kA. The remaining 34% were produced by cloud pulses or lightning events that we were not able to classify.

  11. 77 FR 43614 - Notice of Lodging of Consent Decree Pursuant to the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-25

    ... (``LDAR'') for hazardous air pollutants, 40 CFR Part 63, Subparts A, H and CC, at an asphalt petroleum... penalty. In addition, although the plant has not refined asphalt since 2008, Chevron agrees to implement...

  12. The 29 July 1994 Merritt Island, Fl Microburst: A Case Study Intercomparing Kennedy Space Center Three-Dimensional Lightning Data (LDAR) and WSR-88D Radar Data

    NASA Technical Reports Server (NTRS)

    Hoffert, Steven G.; Pearce, Matt L.

    1996-01-01

    Many researchers have shown that the development and evolution of electrical discharges within convective clouds is fundamentally related to the growth and dynamics of precipitation particles aloft. In the presence of strong updrafts above the freezing level collisions among mixed-phase particles (i.e., hail. ice, supercooled water) promote the necessary charge separation needed to initiate intra-cloud lightning. A precipitation core that descends below the freezing level is often accompanied by a change in the electrical structure of the cloud. Consequently, more Cloud-to-Ground (CG) than Intra-Cloud (IC) lightning flashes appear. Descending precipitation cores can also play a significant role in the evolution of mesoscale features at the surface (e.g., microbursts, downbursts) because of latent heat and mass loading effects of water and ice. For this reason, some believe that lightning and microbursts are fundamentally linked by the presence of ice particles in thunderstorms. Several radar and lightning studies of microburst thunderstorms from COHMEX in 1986 showed that the peak IC lightning systematically occurred ten minutes before the onset of a microburst. In contrast, most CG lightning occurred at the time of the microburst. Many of the preceding studies have been done using high-resolution research radars and experimental lightning detection systems in focused field projects. In addition, these studies could only determine the vertical origin or occurrence of IC lightning, and not a true three-dimensional representation. Currently, the WSR-88D radar system and a real-time, state-of-the-art lightning system (LDAR) at the Kennedy Space Center (KSC) in Florida provide an opportunity to extend these kinds of studies in a more meaningful operational setting.

  13. Development of cost effective fenceline monitoring methods to support advanced leak detection and repair strategies

    EPA Science Inventory

    Improved mitigation of fugitive emissions of hazardous air pollutants (HAPs), volatile organic compounds (VOCs), and greenhouse gas (GHG) emissions is an important emerging topic in many industrial sectors. Efficacious leak detection and repair (LDAR) programs of the future yiel...

  14. PORTABLE IMAGING DEVICES FOR INDUSTRIAL LEAK DETECTION AT PETROLEUM REFINERIES AND CHEMICAL PLANTS

    EPA Science Inventory

    Undiscovered gas leaks, or fugitive emissions, in chemical plants and refinery operations can impact regional air quality as well as being a public health problem. Surveying a facility for potential gas leaks can be a daunting task. Industrial Leak Detection and Repair (LDAR) pro...

  15. 75 FR 78733 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-16

    ... alleges that U.S. Oil violated the National Emission Standards for Hazardous Air Pollutants for Benzene Waste Operations (the ``Benzene NESHAP''), 40 CFR part 61, Subpart FF, the National Emission Standards... Benzene NESHAP compliance program; and (4) implement measures, in addition to compliance with the LDAR...

  16. Observations of Total Lightning Associated with Severe Convection During the Wet Season in Central Florida

    NASA Technical Reports Server (NTRS)

    Sharp, D.; Williams, E.; Weber, M.; Goodman, Steven J.; Raghavan, R.; Matlin, A.; Boldi, B.

    1998-01-01

    This paper will discuss findings of a collaborative lightning research project between National Aeronautics and Space Administration, the Massachusetts Institute of Technology and the National Weather Service office In Melbourne Florida. In August 1996, NWS/MLB received a workstation which incorporates data from the KMLB WSR-88D, Cloud to Ground (CG) stroke data from the National Lightning Detection Network (NLDN), and 3D volumetric lightning data collected from the Kennedy Space Centers' Lightning Detection And Ranging (LDAR) lightning system. The two primary objectives of this lightning workstation, called Lightning Imaging Sensor Data Applications Display (USDAD), are to: observe how total lightning relates to severe convective storm morphology over central Florida, and compare ground based total lightning data (LDAR) to a satellite based lightning detection system. This presentation will focus on objective #1. The LISDAD system continuously displays CG and total lighting activity overlaid on top of the KMLB composite reflectivity product. This allows forecasters to monitor total lightning activity associated with convective cells occurring over the central Florida peninsula and adjacent coastal waters. The LISDAD system also keeps track of the amount of total lightning data, and associated KMLB radar products with individual convective cells occurring over the region. By clicking on an individual cell, a history table displays flash rate information (CG and total lightning) in one minute increments, along with radar parameter trends (echo tops, maximum dBz and height of maximum dBz) every 5 minutes. This history table Is updated continuously, without user intervention, as long as the cell is identified. Reviewing data collected during the 1997 wet season (21 cases) revealed that storms which produced severe weather (hall greater or = 0.75 in. or wind damage) typically showed a rapid rise In total lightning prior to the onset of severe weather. On average, flash rate increases of 25 FPM per minute over a time scale of approximately 5 minutes were common. These pulse severe storms typically reached values of 150 to 200 FPM with some cells exceeding 400 FPM. One finding which could have a direct application to the warning process is that the rapid increase in lightning typically occurred in advance of the warning issuance time. Comparisons between the ending time of the rapid rate increase and the time of when the warning was issued by NWS/MLB meteorologist exhibited a lead time of 8 minutes. It is conceivable that if close monitoring of the LISDAD system by operational meteorologist is routinely performed, warnings for pulse severe storms could be issued up to 4 to 6 minutes earlier than what is issued currently.

  17. Modeling Stepped Leaders Using a Time Dependent Multi-dipole Model and High-speed Video Data

    NASA Astrophysics Data System (ADS)

    Karunarathne, S.; Marshall, T.; Stolzenburg, M.; Warner, T. A.; Orville, R. E.

    2012-12-01

    In summer of 2011, we collected lightning data with 10 stations of electric field change meters (bandwidth of 0.16 Hz - 2.6 MHz) on and around NASA/Kennedy Space Center (KSC) covering nearly 70 km × 100 km area. We also had a high-speed video (HSV) camera recording 50,000 images per second collocated with one of the electric field change meters. In this presentation we describe our use of these data to model the electric field change caused by stepped leaders. Stepped leaders of a cloud to ground lightning flash typically create the initial path for the first return stroke (RS). Most of the time, stepped leaders have multiple complex branches, and one of these branches will create the ground connection for the RS to start. HSV data acquired with a short focal length lens at ranges of 5-25 km from the flash are useful for obtaining the 2-D location of these multiple branches developing at the same time. Using HSV data along with data from the KSC Lightning Detection and Ranging (LDAR2) system and the Cloud to Ground Lightning Surveillance System (CGLSS), the 3D path of a leader may be estimated. Once the path of a stepped leader is obtained, the time dependent multi-dipole model [ Lu, Winn,and Sonnenfeld, JGR 2011] can be used to match the electric field change at various sensor locations. Based on this model, we will present the time-dependent charge distribution along a leader channel and the total charge transfer during the stepped leader phase.

  18. The Design and Evaluation of the Lighting Imaging Sensor Data Applications Display (LISDAD)

    NASA Technical Reports Server (NTRS)

    Boldi, B.; Hodanish, S.; Sharp, D.; Williams, E.; Goodman, Steven; Raghavan, R.; Matlin, A.; Weber, M.

    1998-01-01

    The design and evaluation of the Lightning Imaging Sensor Data Applications Display (LISDAD). The ultimate goal of the LISDAD system is to quantify the utility of total lightning information in short-term, severe-weather forecasting operations. To this end, scientists from NASA, NWS, and MIT organized an effort to study the relationship of lightning and severe-weather on a storm-by-storm, and even cell-by-cell basis for as many storms as possible near Melbourne, Florida. Melbourne was chosen as it offers a unique combination of high probability of severe weather and proximity to major relevant sensors - specifically: NASA's total lightning mapping system at Kennedy Space Center (the LDAR system at KSC); a NWS/NEXRAD radar (at Melbourne); and a prototype Integrated Terminal Weather System (ITWS, at Orlando), which obtains cloud-to-ground lightning Information from the National Lightning Detection Network (NLDN), and also uses NSSL's Severe Storm Algorithm (NSSL/SSAP) to obtain information about various storm-cell parameters. To assist in realizing this project's goal, an interactive, real-time data processing system (the LISDAD system) has been developed that supports both operational short-term weather forecasting and post facto severe-storm research. Suggestions have been drawn from the operational users (NWS/Melbourne) in the design of the data display and its salient behavior. The initial concept for the users Graphical Situation Display (GSD) was simply to overlay radar data with lightning data, but as the association between rapid upward trends in the total lightning rate and severe weather became evident, the display was significantly redesigned. The focus changed to support the display of time series of storm-parameter data and the automatic recognition of cells that display rapid changes in the total-lightning flash rate. The latter is calculated by grouping discrete LDAR radiation sources into lightning flashes using a time-space association algorithm. Specifically, the GSD presents the user with the Composite Maximum Reflectivity obtained from the NWS/NEXRAD. Superimposed upon this background image are placed small black circles indicating the locations of storm cells identified by the NSSL/SSA. The circles become cyan if lightning is detected within the storm-cell; if the cell has lightning rates indicative of a severe-storm, the circle turns red. This paper will: (1) review the design of LISDAD system; (2) present some examples of its data display; and shown results of the lightning based severe-weather prediction algorithm.

  19. Small Negative Cloud-to-Ground Lightning Reports at the KSC-ER

    NASA Technical Reports Server (NTRS)

    Wilson, Jennifer G.; Cummins, Kenneth L.; Krider, E. Philip

    2009-01-01

    '1he NASA Kennedy Space Center (KSC) and Air Force Eastern Range (ER) use data from two cloud-to-ground (CG) lightning detection networks, the CGLSS and the NLDN, and a volumetric lightning mapping array, LDAR, to monitor and characterize lightning that is potentially hazardous to ground or launch operations. Data obtained from these systems during June-August 2006 have been examined to check the classification of small, negative CGLSS reports that have an estimated peak current, [I(sup p)] less than 7 kA, and to determine the smallest values of I(sup p), that are produced by first strokes, by subsequent strokes that create a new ground contact (NGC), and by subsequent strokes that remain in a pre-existing channel (PEC). The results show that within 20 km of the KSC-ER, 21% of the low-amplitude negative CGLSS reports were produced by first strokes, with a minimum I(sup p) of-2.9 kA; 31% were by NGCs, with a minimum I(sup p) of-2.0 kA; and 14% were by PECs, with a minimum I(sup p) of -2.2 kA. The remaining 34% were produced by cloud pulses or lightning events that we were not able to classify.

  20. Scanning, standoff TDLAS leak imaging and quantification

    NASA Astrophysics Data System (ADS)

    Wainner, Richard T.; Aubut, Nicholas F.; Laderer, Matthew C.; Frish, Michael B.

    2017-05-01

    This paper reports a novel quantitative gas plume imaging tool, based on active near-infrared Backscatter Tunable Diode Laser Absorption Spectroscopy (b-TDLAS) technology, designed for upstream natural gas leak applications. The new tool integrates low-cost laser sensors with video cameras to create a highly sensitive gas plume imager that also quantifies emission rate, all in a lightweight handheld ergonomic package. It is intended to serve as a lower-cost, higherperformance, enhanced functionality replacement for traditional passive non-quantitative mid-infrared Optical Gas Imagers (OGI) which are utilized by industry to comply with natural gas infrastructure Leak Detection and Repair (LDAR) requirements. It addresses the need for reliable, robust, low-cost sensors to detect and image methane leaks, and to quantify leak emission rates, focusing on inspections of upstream oil and gas operations, such as well pads, compressors, and gas plants. It provides: 1) Colorized quantified images of path-integrated methane concentration. The images depict methane plumes (otherwise invisible to the eye) actively interrogated by the laser beam overlaid on a visible camera image of the background. The detection sensitivity exceeds passive OGI, thus simplifying the manual task of leak detection and location; and 2) Data and algorithms for using the quantitative information gathered by the active detection technique to deduce plume flux (i.e. methane emission rate). This key capability will enable operators to prioritize leak repairs and thereby minimize the value of lost product, as well as to quantify and minimize greenhouse gas emissions, using a tool that meets EPA LDAR imaging equipment requirements.

  1. Three-Dimensional Radar and Total Lightning Characteristics of Mesoscale Convective Systems

    NASA Astrophysics Data System (ADS)

    McCormick, T. L.; Carey, L. D.; Murphy, M. J.; Demetriades, N. W.

    2002-12-01

    Preliminary analysis of three-dimensional radar and total lightning characteristics for two mesoscale convective systems (MCSs) occurring in the Dallas-Fort Worth, Texas area during 12-13 October 2001 and 7-8 April 2002 are presented. This study utilizes WSR-88D Level II radar (KFWS), Vaisala GAI Inc. Lightning Detection and Ranging II (LDAR II), and National Lightning Detection Network (NLDN) data to gain a better understanding of the structure and evolution of MCSs, with special emphasis on total lightning. More specifically, this research examines the following topics: 1) the characteristics and evolution of total lightning in MCS's, 2) the correlation between radar reflectivity and lightning flash origins in MCSs, 3) the evolution of the dominant cloud-to-ground (CG) lightning polarity and peak current in both the stratiform and convective regions of MCSs, and 4) the similarities and differences in mesoscale structure and lightning behavior between the two MCSs being studied. Results thus far are in good agreement with previous studies. For example, CG lightning polarity in both MCSs is predominately negative (~90%). Also, the storm cells within the MCSs that exhibit very strong updrafts, identified by high (> 50 dBZ) radar reflectivities, weak echo regions, hook echoes, and/or confirmed severe reports, have higher mean lightning flash origin heights than storm cells with weaker updrafts. Finally, a significant increase in total lightning production (from ~10 to ~18 flashes/min) followed by a significant decrease (from ~18 to ~12 to ~5 flashes/min) is evident approximately one-half hour and ten minutes, respectively, prior to tornado touchdown from a severe storm cell located behind the main convective squall line of the 12-13 October 2001 MCS. These preliminary results, as well as other total lightning and radar characteristics of two MCSs, will be presented.

  2. The Characteristics of Total Lightning Activity in Severe Florida Thunderstorms

    NASA Technical Reports Server (NTRS)

    Williams, E.; Goodman, S. J.; Raghavan, R.; Boldi, R.; Matlin, A.; Weber, M.; Hodanish, S.; Sharp, D.

    1997-01-01

    Severe thunderstorms are defined by specific exceedance criteria regarding either wind speed (greater than or equal to 50 kts), hailstone diameter (greater than or equal to 3/4 inch), the occurrence of a tornado, or any combination thereof. Although traditional radar signatures of severe thunderstorms have been well documented, the characteristics of associated total lightning activity (both intracloud and cloud-to-ground) of severe thunderstorms remain poorly established. The reason for this are (1) less than 1% of all storms are actually severe, (2) intracloud lightning, which is typically the dominant form of electrical discharge within thunderstorms, is not routinely measured or recorded, (3) direct visual observations of intracloud lightning are obscured during the daytime, and (4) the migratory nature of many severe thunderstorms can make the accurate detection and mapping of intracloud lightning difficult when using fixed-location sensors. The recent establishment of LISDAD (Lightning Imaging Sensor Data Acquisition and Display - discussed in Goodman et al, this Meeting) has substantially addressed these limitations in east central Florida (ECFL). Analysis of total lightning flash Count histories using the LDAR (Lightning Detection And Ranging) system for known severe thunderstorms (currently irrespective of seasonal aspects and severe storm-type) has revealed flash rates exceeding 1 per second. This appears to be a necessary, but not sufficient,condition for most ECFL severe storm cases. The differences in radar-observed storm structure for high flash rate storms (to include both severe and non-severe categories) will be described together with the timing of peak flash rate vs. the timing of the severe weather manifestation. Comparisons with the satellite-bases OTD (Optical Transient Detector) overhead passes will also be presented when possible.

  3. Drones in Automation - Secured Unmanned Aerial Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morales Rodriguez, Marissa E.; Rooke, Sterling; Fuhr, Peter L.

    Factories, refineries, utilities (water/wastewater, electric) and related industrial sites are complex systems and structures with inspection and maintenance procedures required for optimal operation and regulatory compliance. As a specific example, consider just the bulk electric power system which is comprised of more than 200,000 miles of highvoltage transmission lines, thousands of generation plants and millions of digital controls. More than 1,800 entities own and operate portions of the grid system, with thousands more involved in the operation of distribution networks across North America. The interconnected and interdependent nature of the bulk power system requires a consistent and systematic application ofmore » risk mitigation across the entire grid system to be truly effective. Similar situations are found throughout automation where frequently an aging infrastructure is in place too. Consider, for example, the situation present in a refinery or chemical processing setting with the requirement for leak detection inspection of pipes, interconnects and systems stretching across the plant. The current practices and challenges relating just to this task - leak detection and repair (LDAR) – of detecting any fugitive emissions present and documenting all measurements thereby meeting air compliance regulations are typically “handled” by a small army of individuals with handheld or backpack-sized detectors who crawl through piping racks conducting measurements at each flange. Such work is performed in difficult conditions (temperature, humidity, physically challenging) with frequently a high level of employee turnover. Finaly, enter low cost sensors and mobile platforms – in other words unmanned aerial systems (UASs, or drones) with enhanced sensing capabilities.« less

  4. Drones in Automation - Secured Unmanned Aerial Systems

    DOE PAGES

    Morales Rodriguez, Marissa E.; Rooke, Sterling; Fuhr, Peter L.; ...

    2017-05-01

    Factories, refineries, utilities (water/wastewater, electric) and related industrial sites are complex systems and structures with inspection and maintenance procedures required for optimal operation and regulatory compliance. As a specific example, consider just the bulk electric power system which is comprised of more than 200,000 miles of highvoltage transmission lines, thousands of generation plants and millions of digital controls. More than 1,800 entities own and operate portions of the grid system, with thousands more involved in the operation of distribution networks across North America. The interconnected and interdependent nature of the bulk power system requires a consistent and systematic application ofmore » risk mitigation across the entire grid system to be truly effective. Similar situations are found throughout automation where frequently an aging infrastructure is in place too. Consider, for example, the situation present in a refinery or chemical processing setting with the requirement for leak detection inspection of pipes, interconnects and systems stretching across the plant. The current practices and challenges relating just to this task - leak detection and repair (LDAR) – of detecting any fugitive emissions present and documenting all measurements thereby meeting air compliance regulations are typically “handled” by a small army of individuals with handheld or backpack-sized detectors who crawl through piping racks conducting measurements at each flange. Such work is performed in difficult conditions (temperature, humidity, physically challenging) with frequently a high level of employee turnover. Finaly, enter low cost sensors and mobile platforms – in other words unmanned aerial systems (UASs, or drones) with enhanced sensing capabilities.« less

  5. Lightning activity related to satellite and radar observations of a mesoscale convective system over Texas on 7 8 April 2002

    NASA Astrophysics Data System (ADS)

    Dotzek, Nikolai; Rabin, Robert M.; Carey, Lawrence D.; MacGorman, Donald R.; McCormick, Tracy L.; Demetriades, Nicholas W.; Murphy, Martin J.; Holle, Ronald L.

    2005-07-01

    A multi-sensor study of the leading-line, trailing-stratiform (LLTS) mesoscale convective system (MCS) that developed over Texas in the afternoon of 7 April 2002 is presented. The analysis relies mainly on operationally available data sources such as GOES East satellite imagery, WSR-88D radar data and NLDN cloud-to-ground flash data. In addition, total lightning information in three dimensions from the LDAR II network in the Dallas-Ft. Worth region is used. GOES East satellite imagery revealed several ring-like cloud top structures with a diameter of about 100 km during MCS formation. The Throckmorton tornadic supercell, which had formed just ahead of the developing linear MCS, was characterized by a high CG+ percentage below a V-shaped cloud top overshoot north of the tornado swath. There were indications of the presence of a tilted electrical dipole in this storm. Also this supercell had low average CG- first stroke currents and flash multiplicities. Interestingly, especially the average CG+ flash multiplicity in the Throckmorton storm showed oscillations with an estimated period of about 15 min. Later on, in the mature LLTS MCS, the radar versus lightning activity comparison revealed two dominant discharge regions at the back of the convective leading edge and a gentle descent of the upper intracloud lightning region into the trailing stratiform region, apparently coupled to hydrometeor sedimentation. There was evidence for an inverted dipole in the stratiform region of the LLTS MCS, and CG+ flashes from the stratiform region had high first return stroke peak currents.

  6. Survey of Large Methane Emitters in North America

    NASA Astrophysics Data System (ADS)

    Deiker, S.

    2017-12-01

    It has been theorized that methane emissions in the oil and gas industry follow log normal or "fat tail" distributions, with large numbers of small sources for every very large source. Such distributions would have significant policy and operational implications. Unfortunately, by their very nature such distributions would require large sample sizes to verify. Until recently, such large-scale studies would be prohibitively expensive. The largest public study to date sampled 450 wells, an order of magnitude too low to effectively constrain these models. During 2016 and 2017, Kairos Aerospace conducted a series of surveys the LeakSurveyor imaging spectrometer, mounted on light aircraft. This small, lightweight instrument was designed to rapidly locate large emission sources. The resulting survey covers over three million acres of oil and gas production. This includes over 100,000 wells, thousands of storage tanks and over 7,500 miles of gathering lines. This data set allows us to now probe the distribution of large methane emitters. Results of this survey, and implications for methane emission distribution, methane policy and LDAR will be discussed.

  7. Effects of a Longer Detection Window in VHF Time-of-Arrival Lightning Detection Systems

    NASA Astrophysics Data System (ADS)

    Murphy, M.; Holle, R.; Demetriades, N.

    2003-12-01

    Lightning detection systems that operate by measuring the times of arrival (TOA) of short bursts of radiation at VHF can produce huge volumes of data. The first automated system of this kind, the NASA Kennedy Space Center LDAR network, is capable of producing one detection every 100 usec from each of seven sensors (Lennon and Maier, 1991), where each detection consists of the time and amplitude of the highest-amplitude peak observed within the 100 usec window. More modern systems have been shown to produce very detailed information with one detection every 10 usec (Rison et al., 2001). Operating such systems in real time, however, can become expensive because of the large data communications rates required. One solution to this problem is to use a longer detection window, say 500 usec. In principle, this has little or no effect on the flash detection efficiency because each flash typically produces a very large number of these VHF bursts (known as sources). By simply taking the largest-amplitude peak from every 500-usec interval instead of every 100-usec interval, we should detect the largest 20{%} of the sources that would have been detected using the 100-usec window. However, questions remain about the exact effect of a longer detection window on the source detection efficiency with distance from the network, its effects on how well flashes are represented in space, and how well the reduced information represents the parent thunderstorm. The latter issue is relevant for automated location and tracking of thunderstorm cells using data from VHF TOA lightning detection networks, as well as for understanding relationships between lightning and severe weather. References Lennon, C.L. and L.M. Maier, Lightning mapping system. Proceedings, Intl. Aerospace and Ground Conf. on Lightning and Static Elec., Cocoa Beach, Fla., NASA Conf. Pub. 3106, vol. II, pp. 89-1 - 89-10, 1991. Rison, W., P. Krehbiel, R. Thomas, T. Hamlin, J. Harlin, High time resolution lightning mapping observations of a small thunderstorm during STEPS. Eos Trans. AGU, 82 (47), Fall Meet. Suppl., Abstract AE12A-83, 2001.

  8. Developing empirical lightning cessation forecast guidance for the Kennedy Space Center

    NASA Astrophysics Data System (ADS)

    Stano, Geoffrey T.

    The Kennedy Space Center in east Central Florida is one of the few locations in the country that issues lightning advisories. These forecasts are vital to the daily operations of the Space Center and take on even greater significance during launch operations. The U.S. Air Force's 45th Weather Squadron (45WS), who provides forecasts for the Space Center, has a good record of forecasting the initiation of lightning near their locations of special concern. However, the remaining problem is knowing when to cancel a lightning advisory. Without specific scientific guidelines detailing cessation activity, the Weather Squadron must keep advisories in place longer than necessary to ensure the safety of personnel and equipment. This unnecessary advisory time costs the Space Center millions of dollars in lost manpower each year. This research presents storm and environmental characteristics associated with lightning cessation that then are utilized to create lightning cessation guidelines for isolated thunderstorms for use by the 45WS during the warm season months of May through September. The research uses data from the Lightning Detection and Ranging (LDAR) network at the Kennedy Space Center, which can observe intra-cloud and portions of cloud-to-ground lightning strikes. Supporting data from the Cloud-to-Ground Lightning Surveillance System (CGLSS), radar observations from the Melbourne WSR-88D, and Cape Canaveral morning radiosonde launches also are included. Characteristics of 116 thunderstorms comprising our dataset are presented. Most of these characteristics are based on LDAR-derived spark and flash data and have not been described previously. In particular, the first lightning activity is quantified as either cloud-to-ground (CG) or intra-cloud (IC). Only 10% of the storms in this research are found to initiate with a CG strike. Conversely, only 16% of the storms end with a CG strike. Another characteristic is the average horizontal extent of all the flashes comprising a storm. Our average is 12-14 km, while the greatest flash extends 26 km. Comparisons between the starting altitude of the median and last flashes of a storm are analyzed, with only 37% of the storms having a higher last flash initiating altitude. Additional observations are made of the total lightning flash rate, percentage of CG to IC lightning, trends of individual flash initiation altitudes versus the average initiation altitude, the average inter-flash time distribution, and time series of inter-flash times. Five schemes to forecast lightning cessation are developed and evaluated. 100 of the 116 storms were randomly selected as the dependent sample, while the remaining 16 storms were used for verification. The schemes included a correlation and regression tree analysis, multiple linear regression, trends of storm duration, trend of the altitude of the greatest reflectivity to the time of the final flash, and a percentile scheme. Surprisingly, the percentile method was found to be the most effective technique and the simplest. The inclusion of real time storm parameters is found to have little effect on the results, suggesting that different forecast predictors, such as microphysical data from polarimetric radar, will be necessary to produce improved skill. When the percentile method used a confidence level of 99.5%, it successfully maintained lightning advisories for all 16 independent storms on which the schemes were tested. Since the computed wait time was 25 min, compared to the 45WS' most conservative and accurate wait time of 30 min, the percentile method saves 5 min for each advisory. This 5 min of savings safely shortens the Weather Squadron's advisories and saves money. Additionally, these results are the first to evaluate the 30/30 rule that is used commonly. The success of the percentile method is surprising since it out performs more complex procedures involving correlation and regression tree analysis and regression schemes. These more sophisticated statistical analyses were expected to perform better since they include more predictors in the forecasts. However, with the predictors available to us, this was not the case. While not the expected result, the percentile method succeeds in creating a safe and expedited forecast.

  9. The Anthropogenic/Lightning Effects Around Houston: The Houston Environmental Aerosol Thunderstorm (HEAT) Project - 2005

    NASA Astrophysics Data System (ADS)

    Orville, R. E.

    2004-12-01

    A major field program will occur in summer 2005 to determine the sources and causes for the enhanced cloud-to-ground lightning over Houston, Texas. This program will be in association with simultaneous experiments supported by the Environmental Protection Agency (EPA) and the Texas Commission on Environmental Quality (TCEQ), formally the Texas Natural Resource Conservation Commission (TNRCC). Recent studies covering the period 1989-2002 document a 60 percent increase of cloud-to-ground lightning in the Houston area as compared to surrounding background values, which is second in flash density only to the Tampa Bay, Florida area. We suggest that the elevated flash densities could result from several factors, including 1) the convergence due to the urban heat island effect and complex sea breeze (thermal hypothesis), and 2) the increasing levels of air pollution from anthropogenic sources producing numerous small cloud droplets and thereby suppressing mean droplet size (aerosol hypothesis). The latter effect would enable more cloud water to reach the mixed phase region where it is involved in the formation of precipitation and the separation of electric charge, leading to an enhancement of lightning. The primary goals of HEAT are to examine the effects of (1) pollution, (2) the urban heat island, and (3) the complex coastline on storms and lightning characteristics in the Houston area. The transport of air pollutants by Houston thunderstorms will be investigated. In particular, the relative amounts of lightning-produced and convectively transported NOx into the upper troposphere will be determined, and a comparison of the different NOx sources in the urban area of Houston will be developed. The HEAT project is based on the observation that there is an enhancement in cloud-to-ground (CG) lightning. Total lightning (intracloud (IC) and CG) will be measured using a lightning mapping system (LDAR II) to observe if there is an enhancement in intracloud lightning as well.

  10. Designing and implementing science-based methane policies

    NASA Astrophysics Data System (ADS)

    George, F.

    2017-12-01

    The phenomenal growth in shale gas production across the U.S. has significantly improved the energy security and economic prospects of the country. Natural gas is a "versatile" fuel that has application in every major end-use sector of the economy, both as a fuel and a feedstock. Natural gas has also played a significant role in reducing CO2 emissions from the power sector by displacing more carbon intensive fossil fuels. However, emissions of natural gas (predominantly methane) from the wellhead to the burner tip can erode this environmental benefit. Preserving the many benefits of America's natural gas resources requires smart, science-based policies to optimize the energy delivery efficiency of the natural gas supply chain and ensure that natural gas remains a key pillar in our transition to a low-carbon economy. Southwestern Energy (SWN) is the third largest natural gas producer in the United States. Over the last several years, SWN has participated in a number of scientific studies with regulatory agencies, academia and non-governmental entities that have led to over a dozen peer-reviewed papers on methane emissions from oil and gas operations. This presentation will review how our participation in these studies has informed our internal policies and procedures, as well as our external programs, including the ONE Future coalition (ONE Future). In particular, the presentation will highlight the impact of such studies on our Leak Detection and Repair (LDAR) program, designing new methane research and on the ONE Future initiatives - all with the focus of improving the delivery efficiency of oil and gas operations. Our experience supports continued research in the detection and mitigation of methane emissions, with emphasis on longer duration characterization of methane emissions from oil and gas facilities and further development of cost-effective methane detection and mitigation techniques. We conclude from our scientific and operational experiences that a performance-based methane mitigation policy like the ONE Future will lead to more operationally efficient and cost-effective reductions in methane emissions from the natural gas supply chain.

  11. Satellite laser ranging work at the Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Mcgunigal, T. E.; Carrion, W. J.; Caudill, L. O.; Grant, C. R.; Johnson, T. S.; Premo, D. A.; Spadin, P. L.; Winston, G. C.

    1975-01-01

    Laser ranging systems, their range and accuracy capabilities, and planned improvements for future systems are discussed, the systems include one fixed and two mobile lasers ranging systems. They have demonstrated better than 10 cm accuracy both on a carefully surveyed ground range and in regular satellite ranging operations. They are capable of ranging to all currently launched retroreflector equipped satellites with the exception of Timation III. A third mobile system is discussed which will be accurate to better than 5 cm and will be capable of ranging to distant satellites such as Timation III and LAGEOS.

  12. Trilateration range and range rate system. Volume 1: CDA system manual

    NASA Technical Reports Server (NTRS)

    1976-01-01

    This document is one of a series of manuals designed to provide the information required to operate and maintain the Command and Data Acquisition (CDA) equipment of the Trilateration Range and Range Rate (TRRR) System. Information pertaining to the equipment in the Trilateration Range and Range Rate System which is designed to interface with existing NASA equipment located at Wallops Island, Virginia is presented.

  13. Evaluation of detector dynamic range in the x-ray exposure domain in mammography: a comparison between film-screen and flat panel detector systems.

    PubMed

    Cooper, Virgil N; Oshiro, Thomas; Cagnon, Christopher H; Bassett, Lawrence W; McLeod-Stockmann, Tyler M; Bezrukiy, Nikita V

    2003-10-01

    Digital detectors in mammography have wide dynamic range in addition to the benefit of decoupled acquisition and display. How wide the dynamic range is and how it compares to film-screen systems in the clinical x-ray exposure domain are unclear. In this work, we compare the effective dynamic ranges of film-screen and flat panel mammography systems, along with the dynamic ranges of their component image receptors in the clinical x-ray exposure domain. An ACR mammography phantom was imaged using variable mAs (exposure) values for both systems. The dynamic range of the contrast-limited film-screen system was defined as that ratio of mAs (exposure) values for a 26 kVp Mo/Mo (HVL=0.34 mm Al) beam that yielded passing phantom scores. The same approach was done for the noise-limited digital system. Data from three independent observers delineated a useful phantom background optical density range of 1.27 to 2.63, which corresponded to a dynamic range of 2.3 +/- 0.53. The digital system had a dynamic range of 9.9 +/- 1.8, which was wider than the film-screen system (p<0.02). The dynamic range of the film-screen system was limited by the dynamic range of the film. The digital detector, on the other hand, had an estimated dynamic range of 42, which was wider than the dynamic range of the digital system in its entirety by a factor of 4. The generator/tube combination was the limiting factor in determining the digital system's dynamic range.

  14. Space-Based Range Safety and Future Space Range Applications

    NASA Technical Reports Server (NTRS)

    Whiteman, Donald E.; Valencia, Lisa M.; Simpson, James C.

    2005-01-01

    The National Aeronautics and Space Administration (NASA) Space-Based Telemetry and Range Safety (STARS) study is a multiphase project to demonstrate the performance, flexibility and cost savings that can be realized by using space-based assets for the Range Safety [global positioning system (GPS) metric tracking data, flight termination command and range safety data relay] and Range User (telemetry) functions during vehicle launches and landings. Phase 1 included flight testing S-band Range Safety and Range User hardware in 2003 onboard a high-dynamic aircraft platform at Dryden Flight Research Center (Edwards, California, USA) using the NASA Tracking and Data Relay Satellite System (TDRSS) as the communications link. The current effort, Phase 2, includes hardware and packaging upgrades to the S-band Range Safety system and development of a high data rate Ku-band Range User system. The enhanced Phase 2 Range Safety Unit (RSU) provided real-time video for three days during the historic Global Flyer (Scaled Composites, Mojave, California, USA) flight in March, 2005. Additional Phase 2 testing will include a sounding rocket test of the Range Safety system and aircraft flight testing of both systems. Future testing will include a flight test on a launch vehicle platform. This paper discusses both Range Safety and Range User developments and testing with emphasis on the Range Safety system. The operational concept of a future space-based range is also discussed.

  15. Space-Based Range Safety and Future Space Range Applications

    NASA Technical Reports Server (NTRS)

    Whiteman, Donald E.; Valencia, Lisa M.; Simpson, James C.

    2005-01-01

    The National Aeronautics and Space Administration Space-Based Telemetry and Range Safety study is a multiphase project to demonstrate the performance, flexibility and cost savings that can be realized by using space-based assets for the Range Safety (global positioning system metric tracking data, flight termination command and range safety data relay) and Range User (telemetry) functions during vehicle launches and landings. Phase 1 included flight testing S-band Range Safety and Range User hardware in 2003 onboard a high-dynamic aircraft platform at Dryden Flight Research Center (Edwards, California) using the NASA Tracking and Data Relay Satellite System as the communications link. The current effort, Phase 2, includes hardware and packaging upgrades to the S-band Range Safety system and development of a high data rate Ku-band Range User system. The enhanced Phase 2 Range Safety Unit provided real-time video for three days during the historic GlobalFlyer (Scaled Composites, Mojave, California) flight in March, 2005. Additional Phase 2 testing will include a sounding rocket test of the Range Safety system and aircraft flight testing of both systems. Future testing will include a flight test on a launch vehicle platform. This report discusses both Range Safety and Range User developments and testing with emphasis on the Range Safety system. The operational concept of a future space-based range is also discussed.

  16. Test techniques for determining laser ranging system performance

    NASA Technical Reports Server (NTRS)

    Zagwodzki, T. W.

    1981-01-01

    Procedures and results of an on going test program intended to evaluate laser ranging system performance levels in the field as well as in the laboratory are summarized. Tests show that laser ranging system design requires consideration of time biases and RMS jitters of individual system components. All simple Q switched lasers tested were found to be inadequate for 10 centimeter ranging systems. Timing discriminators operating over a typical 100:1 dynamic signal range may introduce as much as 7 to 9 centimeters of range bias. Time interval units commercially available today are capable of half centimeter performance and are adequate for all field systems currently deployed. Photomultipliers tested show typical tube time biases of one centimeter with single photoelectron transit time jitter of approximately 10 centimeters. Test results demonstrate that NASA's Mobile Laser Ranging System (MOBLAS) receiver configuration is limiting system performance below the 100 photoelectron level.

  17. CO2 laser ranging systems study

    NASA Technical Reports Server (NTRS)

    Filippi, C. A.

    1975-01-01

    The conceptual design and error performance of a CO2 laser ranging system are analyzed. Ranging signal and subsystem processing alternatives are identified, and their comprehensive evaluation yields preferred candidate solutions which are analyzed to derive range and range rate error contributions. The performance results are presented in the form of extensive tables and figures which identify the ranging accuracy compromises as a function of the key system design parameters and subsystem performance indexes. The ranging errors obtained are noted to be within the high accuracy requirements of existing NASA/GSFC missions with a proper system design.

  18. Work probability distribution for a ferromagnet with long-ranged and short-ranged correlations

    NASA Astrophysics Data System (ADS)

    Bhattacharjee, J. K.; Kirkpatrick, T. R.; Sengers, J. V.

    2018-04-01

    Work fluctuations and work probability distributions are fundamentally different in systems with short-ranged versus long-ranged correlations. Specifically, in systems with long-ranged correlations the work distribution is extraordinarily broad compared to systems with short-ranged correlations. This difference profoundly affects the possible applicability of fluctuation theorems like the Jarzynski fluctuation theorem. The Heisenberg ferromagnet, well below its Curie temperature, is a system with long-ranged correlations in very low magnetic fields due to the presence of Goldstone modes. As the magnetic field is increased the correlations gradually become short ranged. Hence, such a ferromagnet is an ideal system for elucidating the changes of the work probability distribution as one goes from a domain with long-ranged correlations to a domain with short-ranged correlations by tuning the magnetic field. A quantitative analysis of this crossover behavior of the work probability distribution and the associated fluctuations is presented.

  19. Accuracy limitations of range-range (spherical) multilateration systems.

    DOT National Transportation Integrated Search

    1973-10-11

    This report presents a novel procedure for determining the accuracy of range-range (or spherical) multilateration systems. The procedure is a generalization of one previously described for hyperbolic multilateration systems. A central result is a dem...

  20. Study of and proposals for the correction of errors in a radar ranging device designed to facilitate docking of a teleoperator maneuvering system

    NASA Technical Reports Server (NTRS)

    Mcdonald, M. W.

    1982-01-01

    A frequency modulated continuous wave radar system was developed. The system operates in the 35 gigahertz frequency range and provides millimeter accuracy range and range rate measurements. This level of range resolution allows soft docking for the proposed teleoperator maneuvering system (TMS) or other autonomous or robotic space vehicles. Sources of error in the operation of the system which tend to limit its range resolution capabilities are identified. Alternative signal processing techniques are explored with emphasis on determination of the effects of inserting various signal filtering circuits in the system. The identification and elimination of an extraneous low frequency signal component created as a result of zero range immediate reflection of radar energy from the surface of the antenna dish back into the mixer of the system is described.

  1. A trunk ranging system based on binocular stereo vision

    NASA Astrophysics Data System (ADS)

    Zhao, Xixuan; Kan, Jiangming

    2017-07-01

    Trunk ranging is an essential function for autonomous forestry robots. Traditional trunk ranging systems based on personal computers are not convenient in practical application. This paper examines the implementation of a trunk ranging system based on the binocular vision theory via TI's DaVinc DM37x system. The system is smaller and more reliable than that implemented using a personal computer. It calculates the three-dimensional information from the images acquired by binocular cameras, producing the targeting and ranging results. The experimental results show that the measurement error is small and the system design is feasible for autonomous forestry robots.

  2. Method of high precision interval measurement in pulse laser ranging system

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong

    2013-09-01

    Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.

  3. High Precision Ranging and Range-Rate Measurements over Free-Space-Laser Communication Link

    NASA Technical Reports Server (NTRS)

    Yang, Guangning; Lu, Wei; Krainak, Michael; Sun, Xiaoli

    2016-01-01

    We present a high-precision ranging and range-rate measurement system via an optical-ranging or combined ranging-communication link. A complete bench-top optical communication system was built. It included a ground terminal and a space terminal. Ranging and range rate tests were conducted in two configurations. In the communication configuration with 622 data rate, we achieved a two-way range-rate error of 2 microns/s, or a modified Allan deviation of 9 x 10 (exp -15) with 10 second averaging time. Ranging and range-rate as a function of Bit Error Rate of the communication link is reported. They are not sensitive to the link error rate. In the single-frequency amplitude modulation mode, we report a two-way range rate error of 0.8 microns/s, or a modified Allan deviation of 2.6 x 10 (exp -15) with 10 second averaging time. We identified the major noise sources in the current system as the transmitter modulation injected noise and receiver electronics generated noise. A new improved system will be constructed to further improve the system performance for both operating modes.

  4. 26 CFR 1.167(l)-4 - Public utility property; election to use asset depreciation range system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... depreciation range system. 1.167(l)-4 Section 1.167(l)-4 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT... Individuals and Corporations § 1.167(l)-4 Public utility property; election to use asset depreciation range system. (a) Application of section 167(l) to certain property subject to asset depreciation range system...

  5. Which Factors Can Protect Against Range Stress in Everyday Usage of Battery Electric Vehicles? Toward Enhancing Sustainability of Electric Mobility Systems.

    PubMed

    Franke, Thomas; Rauh, Nadine; Günther, Madlen; Trantow, Maria; Krems, Josef F

    2016-02-01

    The objective of the present research was to advance understanding of factors that can protect against range anxiety, specifically range stress in everyday usage of battery electric vehicles (BEVs). Range anxiety is a major barrier to the broad adoption of sustainable electric mobility systems. To develop strategies aimed at overcoming range anxiety, a clear understanding of this phenomenon and influencing factors is needed. We examined range anxiety in the form of everyday range stress (ERS) in a field study setting. Seventy-two customers leased a BEV for 3 months. The field study was specifically designed to enable examination of factors that can contribute to lower ERS. In particular, study design and sample recruitment were targeted at generating vehicle usage profiles that would lead to relatively frequent experience of situations requiring active management of range resources and thereby potentially leading to experienced range stress. Less frequent encounter with critical range situations, higher practical experience, subjective range competence, tolerance of low range, and experienced trustworthiness of the range estimation system were related to lower ERS. Moreover, range stress was found to be related to range satisfaction and BEV acceptance. The results underline the importance of the human factors perspective to overcome range anxiety and enhance sustainability of electric mobility systems. Trustworthiness should be employed as a key benchmark variable in the design of range estimation systems, and assistance systems should target increasing drivers' adaptive capacity (i.e., resilience) to cope with critical range situations. © 2015, Human Factors and Ergonomics Society.

  6. NASA Range Safety Annual Report 2007

    NASA Technical Reports Server (NTRS)

    Dumont, Alan G.

    2007-01-01

    As always, Range Safety has been involved in a number of exciting and challenging activities and events. Throughout the year, we have strived to meet our goal of protecting the public, the workforce, and property during range operations. During the past year, Range Safety was involved in the development, implementation, and support of range safety policy. Range Safety training curriculum development was completed this year and several courses were presented. Tailoring exercises concerning the Constellation Program were undertaken with representatives from the Constellation Program, the 45th Space Wing, and the Launch Constellation Range Safety Panel. Range Safety actively supported the Range Commanders Council and it subgroups and remained involved in updating policy related to flight safety systems and flight safety analysis. In addition, Range Safety supported the Space Shuttle Range Safety Panel and addressed policy concerning unmanned aircraft systems. Launch operations at Kennedy Space Center, the Eastern and Western ranges, Dryden Flight Research Center, and Wallops Flight Facility were addressed. Range Safety was also involved in the evaluation of a number of research and development efforts, including the space-based range (formerly STARS), the autonomous flight safety system, the enhanced flight termination system, and the joint advanced range safety system. Flight safety system challenges were evaluated. Range Safety's role in the Space Florida Customer Assistance Service Program for the Eastern Range was covered along with our support for the Space Florida Educational Balloon Release Program. We hope you have found the web-based format both accessible and easy to use. Anyone having questions or wishing to have an article included in the 2008 Range Safety Annual Report should contact Alan Dumont, the NASA Range Safety Program Manager located at the Kennedy Space Center, or Michael Dook at NASA Headquarters.

  7. A high-resolution full-field range imaging system

    NASA Astrophysics Data System (ADS)

    Carnegie, D. A.; Cree, M. J.; Dorrington, A. A.

    2005-08-01

    There exist a number of applications where the range to all objects in a field of view needs to be obtained. Specific examples include obstacle avoidance for autonomous mobile robots, process automation in assembly factories, surface profiling for shape analysis, and surveying. Ranging systems can be typically characterized as being either laser scanning systems where a laser point is sequentially scanned over a scene or a full-field acquisition where the range to every point in the image is simultaneously obtained. The former offers advantages in terms of range resolution, while the latter tend to be faster and involve no moving parts. We present a system for determining the range to any object within a camera's field of view, at the speed of a full-field system and the range resolution of some point laser scans. Initial results obtained have a centimeter range resolution for a 10 second acquisition time. Modifications to the existing system are discussed that should provide faster results with submillimeter resolution.

  8. Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system.

    PubMed

    Saotome, Naoya; Furukawa, Takuji; Hara, Yousuke; Mizushima, Kota; Tansho, Ryohei; Saraya, Yuichi; Shirai, Toshiyuki; Noda, Koji

    2016-04-01

    Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors' facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. The results of this study demonstrate that the authors' range check system is capable of quick and easy range verification with sufficient accuracy.

  9. Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saotome, Naoya, E-mail: naosao@nirs.go.jp; Furukawa, Takuji; Hara, Yousuke

    Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator blockmore » and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.« less

  10. Challenges in miniaturized automotive long-range lidar system design

    NASA Astrophysics Data System (ADS)

    Fersch, Thomas; Weigel, Robert; Koelpin, Alexander

    2017-05-01

    This paper discusses the current technical limitations posed on endeavors to miniaturize lidar systems for use in automotive applications and how to possibly extend those limits. The focus is set on long-range scanning direct time of flight LiDAR systems using APD photodetectors. Miniaturization evokes severe problems in ensuring absolute laser safety while maintaining the systems' performance in terms of maximum range, signal-to-noise ratio, detection probability, pixel density, or frame rate. Based on hypothetical but realistic specifications for an exemplary system the complete lidar signal path is calculated. The maximum range of the system is used as a general performance indicator. It is determined with the minimum signal-to-noise ratio required to detect an object. Various system parameters are varied to find their impact on the system's range. The reduction of the laser's pulse width and the right choice for the transimpedance amplifier's amplification have shown to be practicable measures to double the system's range.

  11. Design and Development of High-Repetition-Rate Satellite Laser Ranging System

    NASA Astrophysics Data System (ADS)

    Choi, Eun-Jung; Bang, Seong-Cheol; Sung, Ki-Pyoung; Lim, Hyung-Chul; Jung, Chan-Gyu; Kim, In-Yeung; Choi, Jae-Seung

    2015-09-01

    The Accurate Ranging System for Geodetic Observation ? Mobile (ARGO-M) was successfully developed as the first Korean mobile Satellite Laser Ranging (SLR) system in 2012, and has joined in the International Laser Ranging Service (ILRS) tracking network, DAEdeoK (DAEK) station. The DAEK SLR station was approved as a validated station in April 2014, through the ILRS station ¡°data validation¡± process. The ARGO-M system is designed to enable 2 kHz laser ranging with millimeter-level precision for geodetic, remote sensing, navigation, and experimental satellites equipped with Laser Retroreflector Arrays (LRAs). In this paper, we present the design and development of a next generation high-repetition-rate SLR system for ARGO-M. The laser ranging rate up to 10 kHz is becoming an important issue in the SLR community to improve ranging precision. To implement high-repetition-rate SLR system, the High-repetition-rate SLR operation system (HSLR-10) was designed and developed using ARGO-M Range Gate Generator (A-RGG), so as to enable laser ranging from 50 Hz to 10 kHz. HSLR-10 includes both hardware controlling software and data post-processing software. This paper shows the design and development of key technologies of high-repetition-rate SLR system. The developed system was tested successfully at DAEK station and then moved to Sejong station, a new Korean SLR station, on July 1, 2015. HSLR-10 will begin normal operations at Sejong station in the near future.

  12. Achieving sub-millimetre precision with a solid-state full-field heterodyning range imaging camera

    NASA Astrophysics Data System (ADS)

    Dorrington, A. A.; Cree, M. J.; Payne, A. D.; Conroy, R. M.; Carnegie, D. A.

    2007-09-01

    We have developed a full-field solid-state range imaging system capable of capturing range and intensity data simultaneously for every pixel in a scene with sub-millimetre range precision. The system is based on indirect time-of-flight measurements by heterodyning intensity-modulated illumination with a gain modulation intensified digital video camera. Sub-millimetre precision to beyond 5 m and 2 mm precision out to 12 m has been achieved. In this paper, we describe the new sub-millimetre class range imaging system in detail, and review the important aspects that have been instrumental in achieving high precision ranging. We also present the results of performance characterization experiments and a method of resolving the range ambiguity problem associated with homodyne and heterodyne ranging systems.

  13. Analysis of ionospheric refraction error corrections for GRARR systems

    NASA Technical Reports Server (NTRS)

    Mallinckrodt, A. J.; Parker, H. C.; Berbert, J. H.

    1971-01-01

    A determination is presented of the ionospheric refraction correction requirements for the Goddard range and range rate (GRARR) S-band, modified S-band, very high frequency (VHF), and modified VHF systems. The relation ships within these four systems are analyzed to show that the refraction corrections are the same for all four systems and to clarify the group and phase nature of these corrections. The analysis is simplified by recognizing that the range rate is equivalent to a carrier phase range change measurement. The equation for the range errors are given.

  14. Navigation for space shuttle approach and landing using an inertial navigation system augmented by data from a precision ranging system or a microwave scan beam landing guidance system

    NASA Technical Reports Server (NTRS)

    Mcgee, L. A.; Smith, G. L.; Hegarty, D. M.; Merrick, R. B.; Carson, T. M.; Schmidt, S. F.

    1970-01-01

    A preliminary study has been made of the navigation performance which might be achieved for the high cross-range space shuttle orbiter during final approach and landing by using an optimally augmented inertial navigation system. Computed navigation accuracies are presented for an on-board inertial navigation system augmented (by means of an optimal filter algorithm) with data from two different ground navigation aids; a precision ranging system and a microwave scanning beam landing guidance system. These results show that augmentation with either type of ground navigation aid is capable of providing a navigation performance at touchdown which should be adequate for the space shuttle. In addition, adequate navigation performance for space shuttle landing is obtainable from the precision ranging system even with a complete dropout of precision range measurements as much as 100 seconds before touchdown.

  15. Fast exposure time decision in multi-exposure HDR imaging

    NASA Astrophysics Data System (ADS)

    Piao, Yongjie; Jin, Guang

    2012-10-01

    Currently available imaging and display system exists the problem of insufficient dynamic range, and the system cannot restore all the information for an high dynamic range (HDR) scene. The number of low dynamic range(LDR) image samples and fastness of exposure time decision impacts the real-time performance of the system dramatically. In order to realize a real-time HDR video acquisition system, this paper proposed a fast and robust method for exposure time selection in under and over exposure area which is based on system response function. The method utilized the monotony of the imaging system. According to this characteristic the exposure time is adjusted to an initial value to make the median value of the image equals to the middle value of the system output range; then adjust the exposure time to make the pixel value on two sides of histogram be the middle value of the system output range. Thus three low dynamic range images are acquired. Experiments show that the proposed method for adjusting the initial exposure time can converge in two iterations which is more fast and stable than average gray control method. As to the exposure time adjusting in under and over exposed area, the proposed method can use the dynamic range of the system more efficiently than fixed exposure time method.

  16. Ranging and tracking system for proximity operations, phase 1

    NASA Technical Reports Server (NTRS)

    Udalov, S.; Nilsen, P. W.

    1979-01-01

    A study task is reported which is directed towards developing a conceptual design of a small, lightweight range and range rate radar sensor system to meet NASA's requirements for accurate short-range and velocity measurements in an orbital environment. Within the context of the requirements, the short range implies system operation at 0 m to 1850 m (6000 ft) and accurate implies a range measurement to within 1 sigma accuracy of 0.20 m (0.67 ft) and a range rate (velocity) measurement to within 1 sigma accuracy of 0.01 m/sec (0.033 ft/sec).

  17. 26 CFR 12.4 - Election of Class Life Asset Depreciation Range System (ADR).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 14 2011-04-01 2010-04-01 true Election of Class Life Asset Depreciation Range... Election of Class Life Asset Depreciation Range System (ADR). (a) Elections filed before February 1, 1972... election will be treated as an election under the Class Life Asset Depreciation Range System (ADR) as...

  18. 26 CFR 12.4 - Election of Class Life Asset Depreciation Range System (ADR).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Election of Class Life Asset Depreciation Range... Election of Class Life Asset Depreciation Range System (ADR). (a) Elections filed before February 1, 1972... election will be treated as an election under the Class Life Asset Depreciation Range System (ADR) as...

  19. 2006 NASA Range Safety Annual Report

    NASA Technical Reports Server (NTRS)

    TenHaken, Ron; Daniels, B.; Becker, M.; Barnes, Zack; Donovan, Shawn; Manley, Brenda

    2007-01-01

    Throughout 2006, Range Safety was involved in a number of exciting and challenging activities and events, from developing, implementing, and supporting Range Safety policies and procedures-such as the Space Shuttle Launch and Landing Plans, the Range Safety Variance Process, and the Expendable Launch Vehicle Safety Program procedures-to evaluating new technologies. Range Safety training development is almost complete with the last course scheduled to go on line in mid-2007. Range Safety representatives took part in a number of panels and councils, including the newly formed Launch Constellation Range Safety Panel, the Range Commanders Council and its subgroups, the Space Shuttle Range Safety Panel, and the unmanned aircraft systems working group. Space based range safety demonstration and certification (formerly STARS) and the autonomous flight safety system were successfully tested. The enhanced flight termination system will be tested in early 2007 and the joint advanced range safety system mission analysis software tool is nearing operational status. New technologies being evaluated included a processor for real-time compensation in long range imaging, automated range surveillance using radio interferometry, and a space based range command and telemetry processor. Next year holds great promise as we continue ensuring safety while pursuing our quest beyond the Moon to Mars.

  20. Dichotomous versus semi-quantitative scoring of ultrasound joint inflammation in rheumatoid arthritis using novel individualized joint selection methods.

    PubMed

    Tan, York Kiat; Allen, John C; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Thumboo, Julian

    2017-05-01

    The aim of the study is to compare the responsiveness of two joint inflammation scoring systems (dichotomous scoring (DS) versus semi-quantitative scoring (SQS)) using novel individualized ultrasound joint selection methods and existing ultrasound joint selection methods. Responsiveness measured by the standardized response means (SRMs) using the DS and the SQS system (for both the novel and existing ultrasound joint selection methods) was derived using the baseline and the 3-month total inflammatory scores from 20 rheumatoid arthritis patients. The relative SRM gain ratios (SRM-Gains) for both scoring system (DS and SQS) comparing the novel to the existing methods were computed. Both scoring systems (DS and SQS) demonstrated substantial SRM-Gains (ranged from 3.31 to 5.67 for the DS system and ranged from 1.82 to 3.26 for the SQS system). The SRMs using the novel methods ranged from 0.94 to 1.36 for the DS system and ranged from 0.89 to 1.11 for the SQS system. The SRMs using the existing methods ranged from 0.24 to 0.32 for the DS system and ranged from 0.34 to 0.49 for the SQS system. The DS system appears to achieve high responsiveness comparable to SQS for the novel individualized ultrasound joint selection methods.

  1. Department of Defense Chemical and Biological Defense Program. FY2004-2006 Performance Plan

    DTIC Science & Technology

    2005-03-01

    Agents (NTAs) Compare the direct effects of PAF on smooth muscle, hematic constituents, and lung to determine role in toxicity. Continue to identify...Range Biometric Target ID System Explore technologies for a long range biometric target identification system. Air Containment Monitoring System...Continue development of systems for contained air monitoring for chemical agents.Long Range Biometric Air Containment Monitoring System Continued

  2. Ultrafast optical ranging using microresonator soliton frequency combs

    NASA Astrophysics Data System (ADS)

    Trocha, P.; Karpov, M.; Ganin, D.; Pfeiffer, M. H. P.; Kordts, A.; Wolf, S.; Krockenberger, J.; Marin-Palomo, P.; Weimann, C.; Randel, S.; Freude, W.; Kippenberg, T. J.; Koos, C.

    2018-02-01

    Light detection and ranging is widely used in science and industry. Over the past decade, optical frequency combs were shown to offer advantages in optical ranging, enabling fast distance acquisition with high accuracy. Driven by emerging high-volume applications such as industrial sensing, drone navigation, or autonomous driving, there is now a growing demand for compact ranging systems. Here, we show that soliton Kerr comb generation in integrated silicon nitride microresonators provides a route to high-performance chip-scale ranging systems. We demonstrate dual-comb distance measurements with Allan deviations down to 12 nanometers at averaging times of 13 microseconds along with ultrafast ranging at acquisition rates of 100 megahertz, allowing for in-flight sampling of gun projectiles moving at 150 meters per second. Combining integrated soliton-comb ranging systems with chip-scale nanophotonic phased arrays could enable compact ultrafast ranging systems for emerging mass applications.

  3. Benefits Derived From Laser Ranging Measurements for Orbit Determination of the GPS Satellite Orbit

    NASA Technical Reports Server (NTRS)

    Welch, Bryan W.

    2007-01-01

    While navigation systems for the determination of the orbit of the Global Position System (GPS) have proven to be very effective, the current research is examining methods to lower the error in the GPS satellite ephemerides below their current level. Two GPS satellites that are currently in orbit carry retro-reflectors onboard. One notion to reduce the error in the satellite ephemerides is to utilize the retro-reflectors via laser ranging measurements taken from multiple Earth ground stations. Analysis has been performed to determine the level of reduction in the semi-major axis covariance of the GPS satellites, when laser ranging measurements are supplemented to the radiometric station keeping, which the satellites undergo. Six ground tracking systems are studied to estimate the performance of the satellite. The first system is the baseline current system approach which provides pseudo-range and integrated Doppler measurements from six ground stations. The remaining five ground tracking systems utilize all measurements from the current system and laser ranging measurements from the additional ground stations utilized within those systems. Station locations for the additional ground sites were taken from a listing of laser ranging ground stations from the International Laser Ranging Service. Results show reductions in state covariance estimates when utilizing laser ranging measurements to solve for the satellite s position component of the state vector. Results also show dependency on the number of ground stations providing laser ranging measurements, orientation of the satellite to the ground stations, and the initial covariance of the satellite's state vector.

  4. A Brief Overview of NASA Glenn Research Center Sensor and Electronics Activities

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.

    2012-01-01

    Aerospace applications require a range of sensing technologies. There is a range of sensor and sensor system technologies being developed using microfabrication and micromachining technology to form smart sensor systems and intelligent microsystems. Drive system intelligence to the local (sensor) level -- distributed smart sensor systems. Sensor and sensor system development examples: (1) Thin-film physical sensors (2) High temperature electronics and wireless (3) "lick and stick" technology. NASA GRC is a world leader in aerospace sensor technology with a broad range of development and application experience. Core microsystems technology applicable to a range of application environmentS.

  5. Damage assessment of long-range rocket system by electromagnetic pulse weapon

    NASA Astrophysics Data System (ADS)

    Cao, Lingyu; Liu, Guoqing; Li, Jinming

    2017-08-01

    This paper analyzes the damage mechanism and characteristics of electromagnetic pulse weapon, establishes the index system of survivability of long-range rocket launcher system, and uses AHP method to establish the combat effectiveness model of long-range rocket missile system. According to the damage mechanism and characteristics of electromagnetic pulse weapon, the damage effect of the remote rocket system is established by using the exponential method to realize the damage efficiency of the remote rocket system.

  6. Electrically optofluidic zoom system with a large zoom range and high-resolution image.

    PubMed

    Li, Lei; Yuan, Rong-Ying; Wang, Jin-Hui; Wang, Qiong-Hua

    2017-09-18

    We report an electrically controlled optofluidic zoom system which can achieve a large continuous zoom change and high-resolution image. The zoom system consists of an optofluidic zoom objective and a switchable light path which are controlled by two liquid optical shutters. The proposed zoom system can achieve a large tunable focal length range from 36mm to 92mm. And in this tuning range, the zoom system can correct aberrations dynamically, thus the image resolution is high. Due to large zoom range, the proposed imaging system incorporates both camera configuration and telescope configuration into one system. In addition, the whole system is electrically controlled by three electrowetting liquid lenses and two liquid optical shutters, therefore, the proposed system is very compact and free of mechanical moving parts. The proposed zoom system has potential to take place of conventional zoom systems.

  7. Resolution verification targets for airborne and spaceborne imaging systems at the Stennis Space Center

    NASA Astrophysics Data System (ADS)

    McKellip, Rodney; Yuan, Ding; Graham, William; Holland, Donald E.; Stone, David; Walser, William E.; Mao, Chengye

    1997-06-01

    The number of available spaceborne and airborne systems will dramatically increase over the next few years. A common systematic approach toward verification of these systems will become important for comparing the systems' operational performance. The Commercial Remote Sensing Program at the John C. Stennis Space Center (SSC) in Mississippi has developed design requirements for a remote sensing verification target range to provide a means to evaluate spatial, spectral, and radiometric performance of optical digital remote sensing systems. The verification target range consists of spatial, spectral, and radiometric targets painted on a 150- by 150-meter concrete pad located at SSC. The design criteria for this target range are based upon work over a smaller, prototypical target range at SSC during 1996. This paper outlines the purpose and design of the verification target range based upon an understanding of the systems to be evaluated as well as data analysis results from the prototypical target range.

  8. Evaluation of the hydrologic system and potential effects of mining in the Dickinson lignite area, eastern slope and western Stark and Hettinger counties, North Dakota

    USGS Publications Warehouse

    Armstrong, C.A.

    1984-01-01

    The investigation of the water resources of the Dickinson lignite area, an area of about 500 square miles, was undertaken to define the hydrologic system of the area and to project probable effects of coal mining on the system.Aquifers occur in sandstone beds in: the Fox Hills Sandstone and the lower Hell Creek Formation of Cretaceous age, the upper Hell Creek Formation of Cretaceous age and the lower Ludlow Member of the Fort Union Formation of Tertiary age, and the upper Ludlow and lower Tongue River Members of the Fort Union Formation of Tertiary age. Aquifers also occur in the sandstone and lignite lenses in the upper Tongue River Member and the Sentinel Butte Member of the Fort Union Formation. Depths to the Fox Hills-lower Hell Creek aquifer system range from about 1,300 to 1,710 feet. Well yields range from 18 to 100 gallons per minute. The water is soft and is a sodium bicarbonate type. Dissolvedsolids concentrations in samples collected from the aquifer system ranged from 1,230 to 1,690 milligrams per liter.Depths to the upper Hell Creek-lower Ludlow aquifer system range from about 720 to 1,040 feet. Well yields generally are less than 30 gallons per minute but may be as much as 150 gallons per minute. The water is soft and a sodium bicarbonate type. Dissolved-solids concentrations in samples collected from the aquifer system ranged from 1,010 to 1,450 milligrams per liter.Depths to the upper Ludlow-lower Tongue River aquifer system range from about 440 to 713 feet. Well yields may range from about 1 to 100 gallons per minute. The water generally is soft and a sodium bicarbonate type but may be moderately hard and a sulfate type in the southwestern part of the area. Dissolved-solids concentrations in samples collected from the aquifer system ranged from 995 to 1,990 milligrams per liter. Depths to the upper Tongue River-Sentinel Butte aquifer system range from near land surface to about 530 feet below land surface. Well yields generally range from about 1 to 185 gallons per minute. Yields from the lignite parts of the system range from about 2 to 60 gallons per minute. The water generally is a sodium bicarbonate type, but locally sulfate is the dominant anion. Dissolved-solids concentrations in samples collected from the aquifer system generally ranged from 574 to 2,720 milligrams per liter.

  9. Modeling methodology for MLS range navigation system errors using flight test data

    NASA Technical Reports Server (NTRS)

    Karmali, M. S.; Phatak, A. V.

    1982-01-01

    Flight test data was used to develop a methodology for modeling MLS range navigation system errors. The data used corresponded to the constant velocity and glideslope approach segment of a helicopter landing trajectory. The MLS range measurement was assumed to consist of low frequency and random high frequency components. The random high frequency component was extracted from the MLS range measurements. This was done by appropriate filtering of the range residual generated from a linearization of the range profile for the final approach segment. This range navigation system error was then modeled as an autoregressive moving average (ARMA) process. Maximum likelihood techniques were used to identify the parameters of the ARMA process.

  10. Advanced Tactical Booster Technologies: Applications for Long-Range Rocket Systems

    DTIC Science & Technology

    2016-09-07

    Applications for Long-Range Rocket Systems 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Matthew McKinna, Jason Mossman 5d...technology advantages currently under development for tactical rocket motors which have direct application to land-based long-range rocket systems...increased rocket payload capacity, improved rocket range or increased rocket loadout from the volumetrically constrained environment of a land-based

  11. Isotope Brayton electric power system for the 500 to 2500 watt range

    NASA Technical Reports Server (NTRS)

    Macosko, R. P.; Barna, G. J.; Block, H. B.; Ingle, B. D.

    1972-01-01

    An extensive study was conducted at the Lewis Research Center to evaluate an isotope Brayton electric power system for use in the 500 to 2500 W power range. Overall system simplicity was emphasized in order to reduce parasitic power losses and improve system reliability. Detailed parametric cycle analysis, conceptual component designs, and evaluation of system packaging were included. A single-loop system (gas) with six major components including one rotating unit was selected. Calculated net system efficiency varies from 23 to 28 percent over the power range.

  12. A comparison of two prompt gamma imaging techniques with collimator-based cameras for range verification in proton therapy

    NASA Astrophysics Data System (ADS)

    Lin, Hsin-Hon; Chang, Hao-Ting; Chao, Tsi-Chian; Chuang, Keh-Shih

    2017-08-01

    In vivo range verification plays an important role in proton therapy to fully utilize the benefits of the Bragg peak (BP) for delivering high radiation dose to tumor, while sparing the normal tissue. For accurately locating the position of BP, camera equipped with collimators (multi-slit and knife-edge collimator) to image prompt gamma (PG) emitted along the proton tracks in the patient have been proposed for range verification. The aim of the work is to compare the performance of multi-slit collimator and knife-edge collimator for non-invasive proton beam range verification. PG imaging was simulated by a validated GATE/GEANT4 Monte Carlo code to model the spot-scanning proton therapy and cylindrical PMMA phantom in detail. For each spot, 108 protons were simulated. To investigate the correlation between the acquired PG profile and the proton range, the falloff regions of PG profiles were fitted with a 3-line-segment curve function as the range estimate. Factors including the energy window setting, proton energy, phantom size, and phantom shift that may influence the accuracy of detecting range were studied. Results indicated that both collimator systems achieve reasonable accuracy and good response to the phantom shift. The accuracy of range predicted by multi-slit collimator system is less affected by the proton energy, while knife-edge collimator system can achieve higher detection efficiency that lead to a smaller deviation in predicting range. We conclude that both collimator systems have potentials for accurately range monitoring in proton therapy. It is noted that neutron contamination has a marked impact on range prediction of the two systems, especially in multi-slit system. Therefore, a neutron reduction technique for improving the accuracy of range verification of proton therapy is needed.

  13. The value of forage measurement information in rangeland management. [implementation of satellite data in range management

    NASA Technical Reports Server (NTRS)

    Lietzke, K. R.

    1975-01-01

    An economic model and simulation are developed to estimate the potential social benefit arising from the use of alternative measurement systems in rangeland management. In order to estimate these benefits, it was necessary to model three separate systems: the range environment, the rangeland manager, and the information system which links the two. The rancher's decision-making behavior is modeled according to sound economic principles. Results indicate substantial potential benefits, particularly when used in assisting management of government-operated ranges; possible annual benefits in this area range from $20 to $46 million, depending upon the system capabilities assumed. Possible annual benefit in privately-managed stocker operations range from $2.8 to $49.5 million, depending upon where actual rancher capabilities lie and what system capabilities are assumed.

  14. SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samuel, D; Testa, M; Park, Y

    Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separablemore » into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.« less

  15. Motion Estimation Utilizing Range Detection-Enhanced Visual Odometry

    NASA Technical Reports Server (NTRS)

    Morris, Daniel Dale (Inventor); Chang, Hong (Inventor); Friend, Paul Russell (Inventor); Chen, Qi (Inventor); Graf, Jodi Seaborn (Inventor)

    2016-01-01

    A motion determination system is disclosed. The system may receive a first and a second camera image from a camera, the first camera image received earlier than the second camera image. The system may identify corresponding features in the first and second camera images. The system may receive range data comprising at least one of a first and a second range data from a range detection unit, corresponding to the first and second camera images, respectively. The system may determine first positions and the second positions of the corresponding features using the first camera image and the second camera image. The first positions or the second positions may be determined by also using the range data. The system may determine a change in position of the machine based on differences between the first and second positions, and a VO-based velocity of the machine based on the determined change in position.

  16. Laser-ranging scanning system to observe topographical deformations of volcanoes.

    PubMed

    Aoki, T; Takabe, M; Mizutani, K; Itabe, T

    1997-02-20

    We have developed a laser-ranging system to observe the topographical structure of volcanoes. This system can be used to measure the distance to a target by a laser and shows the three-dimensional topographical structure of a volcano with an accuracy of 30 cm. This accuracy is greater than that of a typical laser-ranging system that uses a corner-cube reflector as a target because the reflected light jitters as a result of inclination and unevenness of the target ground surface. However, this laser-ranging system is useful for detecting deformations of topographical features in which placement of a reflector is difficult, such as in volcanic regions.

  17. Influence of range-gated intensifiers on underwater imaging system SNR

    NASA Astrophysics Data System (ADS)

    Wang, Xia; Hu, Ling; Zhi, Qiang; Chen, Zhen-yue; Jin, Wei-qi

    2013-08-01

    Range-gated technology has been a hot research field in recent years due to its high effective back scattering eliminating. As a result, it can enhance the contrast between a target and its background and extent the working distance of the imaging system. The underwater imaging system is required to have the ability to image in low light level conditions, as well as the ability to eliminate the back scattering effect, which means that the receiver has to be high-speed external trigger function, high resolution, high sensitivity, low noise, higher gain dynamic range. When it comes to an intensifier, the noise characteristics directly restrict the observation effect and range of the imaging system. The background noise may decrease the image contrast and sharpness, even covering the signal making it impossible to recognize the target. So it is quite important to investigate the noise characteristics of intensifiers. SNR is an important parameter reflecting the noise features of a system. Through the use of underwater laser range-gated imaging prediction model, and according to the linear SNR system theory, the gated imaging noise performance of the present market adopted super second generation and generation Ⅲ intensifiers were theoretically analyzed. Based on the active laser underwater range-gated imaging model, the effect to the system by gated intensifiers and the relationship between the system SNR and MTF were studied. Through theoretical and simulation analysis to the image intensifier background noise and SNR, the different influence on system SNR by super second generation and generation Ⅲ ICCD was obtained. Range-gated system SNR formula was put forward, and compared the different effect influence on the system by using two kind of ICCDs was compared. According to the matlab simulation, a detailed analysis was carried out theoretically. All the work in this paper lays a theoretical foundation to further eliminating back scattering effect, improving image SNR, designing and manufacturing higher performance underwater range-gated imaging systems.

  18. Improved pulse laser ranging algorithm based on high speed sampling

    NASA Astrophysics Data System (ADS)

    Gao, Xuan-yi; Qian, Rui-hai; Zhang, Yan-mei; Li, Huan; Guo, Hai-chao; He, Shi-jie; Guo, Xiao-kang

    2016-10-01

    Narrow pulse laser ranging achieves long-range target detection using laser pulse with low divergent beams. Pulse laser ranging is widely used in military, industrial, civil, engineering and transportation field. In this paper, an improved narrow pulse laser ranging algorithm is studied based on the high speed sampling. Firstly, theoretical simulation models have been built and analyzed including the laser emission and pulse laser ranging algorithm. An improved pulse ranging algorithm is developed. This new algorithm combines the matched filter algorithm and the constant fraction discrimination (CFD) algorithm. After the algorithm simulation, a laser ranging hardware system is set up to implement the improved algorithm. The laser ranging hardware system includes a laser diode, a laser detector and a high sample rate data logging circuit. Subsequently, using Verilog HDL language, the improved algorithm is implemented in the FPGA chip based on fusion of the matched filter algorithm and the CFD algorithm. Finally, the laser ranging experiment is carried out to test the improved algorithm ranging performance comparing to the matched filter algorithm and the CFD algorithm using the laser ranging hardware system. The test analysis result demonstrates that the laser ranging hardware system realized the high speed processing and high speed sampling data transmission. The algorithm analysis result presents that the improved algorithm achieves 0.3m distance ranging precision. The improved algorithm analysis result meets the expected effect, which is consistent with the theoretical simulation.

  19. Performance Analysis of Ranging Techniques for the KPLO Mission

    NASA Astrophysics Data System (ADS)

    Park, Sungjoon; Moon, Sangman

    2018-03-01

    In this study, the performance of ranging techniques for the Korea Pathfinder Lunar Orbiter (KPLO) space communication system is investigated. KPLO is the first lunar mission of Korea, and pseudo-noise (PN) ranging will be used to support the mission along with sequential ranging. We compared the performance of both ranging techniques using the criteria of accuracy, acquisition probability, and measurement time. First, we investigated the end-to-end accuracy error of a ranging technique incorporating all sources of errors such as from ground stations and the spacecraft communication system. This study demonstrates that increasing the clock frequency of the ranging system is not required when the dominant factor of accuracy error is independent of the thermal noise of the ranging technique being used in the system. Based on the understanding of ranging accuracy, the measurement time of PN and sequential ranging are further investigated and compared, while both techniques satisfied the accuracy and acquisition requirements. We demonstrated that PN ranging performed better than sequential ranging in the signal-to-noise ratio (SNR) regime where KPLO will be operating, and we found that the T2B (weighted-voting balanced Tausworthe, voting v = 2) code is the best choice among the PN codes available for the KPLO mission.

  20. Estimate of the influence of muzzle smoke on function range of infrared system

    NASA Astrophysics Data System (ADS)

    Luo, Yan-ling; Wang, Jun; Wu, Jiang-hui; Wu, Jun; Gao, Meng; Gao, Fei; Zhao, Yu-jie; Zhang, Lei

    2013-09-01

    Muzzle smoke produced by weapons shooting has important influence on infrared (IR) system while detecting targets. Based on the theoretical model of detecting spot targets and surface targets of IR system while there is muzzle smoke, the function range for detecting spot targets and surface targets are deduced separately according to the definition of noise equivalent temperature difference(NETD) and minimum resolution temperature difference(MRTD). Also parameters of muzzle smoke affecting function range of IR system are analyzed. Base on measured data of muzzle smoke for single shot, the function range of an IR system for detecting typical targets are calculated separately while there is muzzle smoke and there is no muzzle smoke at 8-12 micron waveband. For our IR system function range has reduced by over 10% for detecting tank if muzzle smoke exists. The results will provide evidence for evaluating the influence of muzzle smoke on IR system and will help researchers to improve ammo craftwork.

  1. A high dynamic range pulse counting detection system for mass spectrometry.

    PubMed

    Collings, Bruce A; Dima, Martian D; Ivosev, Gordana; Zhong, Feng

    2014-01-30

    A high dynamic range pulse counting system has been developed that demonstrates an ability to operate at up to 2e8 counts per second (cps) on a triple quadrupole mass spectrometer. Previous pulse counting detection systems have typically been limited to about 1e7 cps at the upper end of the systems dynamic range. Modifications to the detection electronics and dead time correction algorithm are described in this paper. A high gain transimpedance amplifier is employed that allows a multi-channel electron multiplier to be operated at a significantly lower bias potential than in previous pulse counting systems. The system utilises a high-energy conversion dynode, a multi-channel electron multiplier, a high gain transimpedance amplifier, non-paralysing detection electronics and a modified dead time correction algorithm. Modification of the dead time correction algorithm is necessary due to a characteristic of the pulse counting electronics. A pulse counting detection system with the capability to count at ion arrival rates of up to 2e8 cps is described. This is shown to provide a linear dynamic range of nearly five orders of magnitude for a sample of aprazolam with concentrations ranging from 0.0006970 ng/mL to 3333 ng/mL while monitoring the m/z 309.1 → m/z 205.2 transition. This represents an upward extension of the detector's linear dynamic range of about two orders of magnitude. A new high dynamic range pulse counting system has been developed demonstrating the ability to operate at up to 2e8 cps on a triple quadrupole mass spectrometer. This provides an upward extension of the detector's linear dynamic range by about two orders of magnitude over previous pulse counting systems. Copyright © 2013 John Wiley & Sons, Ltd.

  2. TU-FG-BRB-05: A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draeger, E; Chen, H; Polf, J

    2016-06-15

    Purpose: To report on the initial developments of a clinical 3-dimensional (3D) prompt gamma (PG) imaging system for proton radiotherapy range verification. Methods: The new imaging system under development consists of a prototype Compton camera to measure PG emission during proton beam irradiation and software to reconstruct, display, and analyze 3D images of the PG emission. For initial test of the system, PGs were measured with a prototype CC during a 200 cGy dose delivery with clinical proton pencil beams (ranging from 100 MeV – 200 MeV) to a water phantom. Measurements were also carried out with the CC placedmore » 15 cm from the phantom for a full range 150 MeV pencil beam and with its range shifted by 2 mm. Reconstructed images of the PG emission were displayed by the clinical PG imaging software and compared to the dose distributions of the proton beams calculated by a commercial treatment planning system. Results: Measurements made with the new PG imaging system showed that a 3D image could be reconstructed from PGs measured during the delivery of 200 cGy of dose, and that shifts in the Bragg peak range of as little as 2 mm could be detected. Conclusion: Initial tests of a new PG imaging system show its potential to provide 3D imaging and range verification for proton radiotherapy. Based on these results, we have begun work to improve the system with the goal that images can be produced from delivery of as little as 20 cGy so that the system could be used for in-vivo proton beam range verification on a daily basis.« less

  3. SCD's uncooled detectors and video engines for a wide-range of applications

    NASA Astrophysics Data System (ADS)

    Fraenkel, A.; Mizrahi, U.; Bikov, L.; Giladi, A.; Shiloah, N.; Elkind, S.; Kogan, I.; Maayani, S.; Amsterdam, A.; Vaserman, I.; Duman, O.; Hirsh, Y.; Schapiro, F.; Tuito, A.; Ben-Ezra, M.

    2011-06-01

    Over the last decade SCD has established a state of the art VOx μ-Bolometer product line. Due to its overall advantages this technology is penetrating a large range of systems. In addition to a large variety of detectors, SCD has also recently introduced modular video engines with an open architecture. In this paper we will describe the versatile applications supported by the products based on 17μm pitch: Low SWaP short range systems, mid range systems based on VGA arrays and high-end systems that will utilize the XGA format. These latter systems have the potential to compete with cooled 2nd Gen scanning LWIR arrays, as will be demonstrated by TRM3 system level calculations.

  4. Long Range Plan for Information Systems from the State Board of Education.

    ERIC Educational Resources Information Center

    Texas Education Agency, Austin.

    The Information Systems Long Range Plan specifically addresses Goal four of the Texas State Board of Education's (SBOE's) "Long-Range Plan for Public School Education" dealing with efficient management and organization of the educational system. To facilitate this goal, the SBOE in 1986 approved and directed the Texas Education Agency to…

  5. Effect of production system (barn and free range) and slaughter age on some production traits of guinea fowl.

    PubMed

    Yamak, U S; Sarica, M; Boz, M A; Ucar, A

    2018-01-01

    A total of 200 guinea fowl was reared in either barn or free-range systems and slaughtered at 14, 16, or 18 wk of age in order to determine the effects of production system on live weight, feed consumption, and some carcass and slaughter traits. Production system had a significant effect on live weight until 14 wk of age. Live weights were similar between free-range and indoor production systems at 16 (1,150 g vs. 1,152 g) and 18 (1,196 g vs. 1,203 g) wk of age. Guinea fowl reared in a free-range system consumed more feed (7,693 g vs. 6,983 g), and guinea fowl reared in a barn had better feed conversion ratio (5.80 vs. 6.43) (P < 0.05). Production system, gender, and slaughter age did not affect the dressing percentage. Guinea fowl reared in a free-range system had significantly less abdominal fat (P < 0.05). © 2017 Poultry Science Association Inc.

  6. 33 CFR 62.41 - Ranges.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Ranges. 62.41 Section 62.41 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.41 Ranges. Ranges are aids to...

  7. 33 CFR 62.41 - Ranges.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Ranges. 62.41 Section 62.41 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.41 Ranges. Ranges are aids to...

  8. 33 CFR 62.41 - Ranges.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Ranges. 62.41 Section 62.41 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.41 Ranges. Ranges are aids to...

  9. 33 CFR 62.41 - Ranges.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Ranges. 62.41 Section 62.41 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.41 Ranges. Ranges are aids to...

  10. 33 CFR 62.41 - Ranges.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Ranges. 62.41 Section 62.41 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.41 Ranges. Ranges are aids to...

  11. Upgrading and performance of the SAO laser ranging system in Matera

    NASA Technical Reports Server (NTRS)

    Maddox, J.; Pearlman, M.; Throp, J.; Wohn, J.

    1983-01-01

    The performance of the SAO lasers was improved considerably in terms of accuracy, range noise, data yield, and reliability. With the narrower laser pulse (2.5-3.0 nsec) and a new analog pulse processing system, the systematic range errors were reduced to 3-5 cm and range noise has been reduced to 5-15 cm on low satellites and 10-18 cm on Lageos. Pulse repetition rate was increased to 30 ppm and considerable improvement has been made in signal-to-noise ratio by using a 3 Angstrom interference filter and by reducing the range gate window down to 200-400 nsec. The first upgraded system was installed in Arequipa, Peru in the spring of 1982. The second upgraded system is now in operation in Matera, Italy. The third system is expected to be installed in Israel during 1984.

  12. Structural and lithologic study of northern coast ranges and Sacramento Valley, California

    NASA Technical Reports Server (NTRS)

    Rich, E. I. (Principal Investigator)

    1973-01-01

    The author has identified the following significant results. Analysis of ERTS-1 imagery of the Northern California Coast Ranges has disclosed a potential relation between a heretofore unrecognized fracture system and known deposits of mercury and geothermally active areas in the Coast Range and between oil and gas fields in the Sacramento Valley. Three potentially important systems of linear elements within the Coast Ranges, detected on ERTS-1 imagery, may represent fault systems or zones of shearing because topographic offset and stratigraph disruption can be seen along one or two of the lineations. One of the systems in subparallel to the San Andreas fault and is confined to the Pacific Coastal Belt. Another set is confined to the central core of the Coast Ranges. The third set of linear features (Valley System) has not heretofore been recognized. Some of the known mercury deposits and geothermally active areas near Clear Lake, in the Coast Ranges, are along the Valley System or at the intersection of the Central and Valley Systems. The plotted locations of some of the oil and gas fields in the Sacramento Valley are associated with the Valley and/or Central Systems. If these relations prove reliable, the ERTS-1 imagery may prove to be an extremely useful exploration tool.

  13. The WSMR Timing System: Toward New Horizons

    NASA Technical Reports Server (NTRS)

    Gilbert, William A.; Stimets, Bob

    1996-01-01

    In 1991, White Sands Missile Range (WSMR) initiated a modernization program for its range timing system. The main focus of this modernization program was to develop a system that was highly accurate, easy to maintain, and portable. The logical decision at the time was to develop a system based solely on Global Positioning System (GPS) technology. Since that time, wsmr has changed its philosophy on how GPS would be utilized for the timing system. This paper will describe WSMR's initial modernization plans for its range timing system and how certain events have led to a modification of these plans.

  14. Bounds on Energy Absorption and Prethermalization in Quantum Systems with Long-Range Interactions

    NASA Astrophysics Data System (ADS)

    Ho, Wen Wei; Protopopov, Ivan; Abanin, Dmitry A.

    2018-05-01

    Long-range interacting systems such as nitrogen vacancy centers in diamond and trapped ions serve as experimental setups to probe a range of nonequilibrium many-body phenomena. In particular, via driving, various effective Hamiltonians with physics potentially quite distinct from short-range systems can be realized. In this Letter, we derive general rigorous bounds on the linear response energy absorption rates of periodically driven systems of spins or fermions with long-range interactions that are sign changing and fall off as 1 /rα with α >d /2 . We show that the disorder averaged energy absorption rate at high temperatures decays exponentially with the driving frequency. This strongly suggests the presence of a prethermal plateau in which dynamics is governed by an effective, static Hamiltonian for long times, and we provide numerical evidence to support such a statement. Our results are relevant for understanding timescales of heating and new dynamical regimes described by effective Hamiltonians in such long-range systems.

  15. Effects of various runway lighting parameters upon the relation between runway visual range and visual range of centerline and edge lights in fog

    NASA Technical Reports Server (NTRS)

    Haines, R. F.

    1973-01-01

    Thirty six students and 54 commercial airline pilots were tested in the fog chamber to determine the effect of runway edge and centerline light intensity and spacing, fog density, ambient luminance level, and lateral and vertical offset distance of the subject from the runway's centerline upon horizontal visual range. These data were obtained to evaluate the adequacy of a balanced lighting system to provide maximum visual range in fog viewing both centerline and runway edge lights. The daytime system was compared against two other candidate lighting systems; the nighttime system was compared against other candidate lighting systems. The second objective was to determine if visual range is affected by lights between the subject and the farthestmost light visible through the fog. The third objective was to determine if college student subjects differ from commercial airline pilots in their horizontal visual range through fog. Two studies were conducted.

  16. Precision laser range finder system design for Advanced Technology Laboratory applications

    NASA Technical Reports Server (NTRS)

    Golden, K. E.; Kohn, R. L.; Seib, D. H.

    1974-01-01

    Preliminary system design of a pulsed precision ruby laser rangefinder system is presented which has a potential range resolution of 0.4 cm when atmospheric effects are negligible. The system being proposed for flight testing on the advanced technology laboratory (ATL) consists of a modelocked ruby laser transmitter, course and vernier rangefinder receivers, optical beacon retroreflector tracking system, and a network of ATL tracking retroreflectors. Performance calculations indicate that spacecraft to ground ranging accuracies of 1 to 2 cm are possible.

  17. Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector.

    PubMed

    Hui, CheukKai; Robertson, Daniel; Alsanea, Fahed; Beddar, Sam

    2015-08-01

    Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to 1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and 2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams.

  18. Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector

    PubMed Central

    Hui, CheukKai; Robertson, Daniel; Alsanea, Fahed; Beddar, Sam

    2016-01-01

    Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to 1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and 2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams. PMID:27274863

  19. The X-33 range Operations Control Center

    NASA Technical Reports Server (NTRS)

    Shy, Karla S.; Norman, Cynthia L.

    1998-01-01

    This paper describes the capabilities and features of the X-33 Range Operations Center at NASA Dryden Flight Research Center. All the unprocessed data will be collected and transmitted over fiber optic lines to the Lockheed Operations Control Center for real-time flight monitoring of the X-33 vehicle. By using the existing capabilities of the Western Aeronautical Test Range, the Range Operations Center will provide the ability to monitor all down-range tracking sites for the Extended Test Range systems. In addition to radar tracking and aircraft telemetry data, the Telemetry and Radar Acquisition and Processing System is being enhanced to acquire vehicle command data, differential Global Positioning System corrections and telemetry receiver signal level status. The Telemetry and Radar Acquisition Processing System provides the flexibility to satisfy all X-33 data processing requirements quickly and efficiently. Additionally, the Telemetry and Radar Acquisition Processing System will run a real-time link margin analysis program. The results of this model will be compared in real-time with actual flight data. The hardware and software concepts presented in this paper describe a method of merging all types of data into a common database for real-time display in the Range Operations Center in support of the X-33 program. All types of data will be processed for real-time analysis and display of the range system status to ensure public safety.

  20. On-line range prediction system, part 2

    NASA Technical Reports Server (NTRS)

    Levan, Nhan

    1988-01-01

    The on-line range prediction system is designed for providing a prediction of the target range in the case of a laser data dropout. It consists of real time implementation of a Kalman filter on an IBM PC/AT equipped with necessary hardware. The system was set up and tested at Crows Landing in the Fall of 1987. The improvements made on the on-line range prediction system during 1988 are examined. Solutions are proposed and discussed to the several problems encountered during system tests. Then, the improvements made on the filter software are explained, namely, accounting for the time lag and providing data continously. Finally, the ideas are mentioned that can be considered in the future.

  1. Individual differences in BEV drivers' range stress during first encounter of a critical range situation.

    PubMed

    Franke, Thomas; Rauh, Nadine; Krems, Josef F

    2016-11-01

    It is commonly held that range anxiety, in the form of experienced range stress, constitutes a usage barrier, particularly during the early period of battery electric vehicle (BEV) usage. To better understand factors that play a role in range stress during this critical period of adaptation to limited-range mobility, we examined individual differences in experienced range stress in the context of a critical range situation. In a field experiment, 74 participants drove a BEV on a 94-km round trip, which was tailored to lead to a critical range situation (i.e., small available range safety buffer). Higher route familiarity, trust in the range estimation system, system knowledge, subjective range competence, and internal control beliefs in dealing with technology were clearly related to lower experienced range stress; emotional stability (i.e., low neuroticism) was partly related to lower range stress. These results can inform strategies aimed at reducing range stress during early BEV usage, as well as contribute to a better understanding of factors that drive user experience in low-resource systems, which is a key topic in the field of green ergonomics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Entanglement Generation and Area Law with Long-Range Interactions

    NASA Astrophysics Data System (ADS)

    Gorshkov, Alexey

    In short-range interacting systems, the speed at which entanglement can be established between two separated points is limited by a constant Lieb-Robinson velocity. This same limit also leads to the so-called area-law bound on entanglement in one-dimensional gapped short-range interacting systems. In this talk, we will show that long-range interactions that decay with distance as a power law allow for faster entanglement generation and state transfer. We will also present sufficient conditions for the area law in gapped systems to hold even in the presence of long-range interactions.

  3. The research of binocular vision ranging system based on LabVIEW

    NASA Astrophysics Data System (ADS)

    Li, Shikuan; Yang, Xu

    2017-10-01

    Based on the study of the principle of binocular parallax ranging, a binocular vision ranging system is designed and built. The stereo matching algorithm is realized by LabVIEW software. The camera calibration and distance measurement are completed. The error analysis shows that the system fast, effective, can be used in the corresponding industrial occasions.

  4. Influence of Waveform Characteristics on LiDAR Ranging Accuracy and Precision

    PubMed Central

    Yang, Bingwei; Xie, Xinhao; Li, Duan

    2018-01-01

    Time of flight (TOF) based light detection and ranging (LiDAR) is a technology for calculating distance between start/stop signals of time of flight. In lab-built LiDAR, two ranging systems for measuring flying time between start/stop signals include time-to-digital converter (TDC) that counts time between trigger signals and analog-to-digital converter (ADC) that processes the sampled start/stop pulses waveform for time estimation. We study the influence of waveform characteristics on range accuracy and precision of two kinds of ranging system. Comparing waveform based ranging (WR) with analog discrete return system based ranging (AR), a peak detection method (WR-PK) shows the best ranging performance because of less execution time, high ranging accuracy, and stable precision. Based on a novel statistic mathematical method maximal information coefficient (MIC), WR-PK precision has a high linear relationship with the received pulse width standard deviation. Thus keeping the received pulse width of measuring a constant distance as stable as possible can improve ranging precision. PMID:29642639

  5. Characterization of the Q-switched MOBLAS Laser Transmitter and Its Ranging Performance Relative to a PTM Q-switched System

    NASA Technical Reports Server (NTRS)

    Degnan, J. J., III; Zagwodski, T. W.

    1979-01-01

    A prototype Q-switched Nd:YAG laser transmitter intended for use in the NASA mobile laser ranging system was subjected to various tests of temporal pulse shape and stability, output energy and stability, beam divergence, and range bias errors. Peak to peak variations in the mean range were as large as 30 cm and drift rates of system bias with time as large as 6 mm per minute of operation were observed. The incorporation of a fast electro-optic cavity dump into the oscillator gave significantly improved results. Reevaluation of the ranging performance after modification showed a reduction in the peak to peak variation in the mean range to the 2 or 3 cm level and a drift rate of system time biases of less than 1 mm per minute of operation. A qualitative physical explanation for the superior performance of cavity dumped lasers is given.

  6. Laser Technology in Interplanetary Exploration: The Past and the Future

    NASA Technical Reports Server (NTRS)

    Smith, David E.

    2000-01-01

    Laser technology has been used in planetary exploration for many years but it has only been in the last decade that laser altimeters and ranging systems have been selected as flight instruments alongside cameras, spectrometers, magnetometers, etc. Today we have an active laser system operating at Mars and another destined for the asteroid Eros. A few years ago a laser ranging system on the Clementine mission changed much of our thinking about the moon and in a few years laser altimeters will be on their way to Mercury, and also to Europa. Along with the increased capabilities and reliability of laser systems has came the realization that precision ranging to the surface of planetary bodies from orbiting spacecraft enables more scientific problems to be addressed, including many associated with planetary rotation, librations, and tides. In addition, new Earth-based laser ranging systems working with similar systems on other planetary bodies in an asynchronous transponder mode will be able to make interplanetary ranging measurements at the few cm level and will advance our understanding of solar system dynamics and relativistic physics.

  7. SU-F-J-190: Time Resolved Range Measurement System Using Scintillator and CCD Camera for the Slow Beam Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saotome, N; Furukawa, T; Mizushima, K

    2016-06-15

    Purpose: To investigate the time structure of the range, we have verified the rang shift due to the betatron tune shift with several synchrotron parameters. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. Using image processing, the range was determined the 80 percent of distal dose of the depth light distribution. The root mean square error of the range measurement using the scintillator and CCD system is about 0.2 mm. Range measurement was performed at interval of 170 msec. The chromaticity of the synchrotron was changed in the range of plus ormore » minus 1% from reference chromaticity in this study. All of the particle inside the synchrotron ring were extracted with the output beam intensity 1.8×10{sup 8} and 5.0×10{sub 7} particle per sec. Results: The time strictures of the range were changed by changing of the chromaticity. The reproducibility of the measurement was sufficient to observe the time structures of the range. The range shift was depending on the number of the residual particle inside the synchrotron ring. Conclusion: In slow beam extraction for scanned carbon-ion therapy, the range shift is undesirable because it causes the dose uncertainty in the target. We introduced the time-resolved range measurement using scintillator and CCD system. The scintillator and CCD system have enabled to verify the range shift with sufficient spatial resolution and reproducibility.« less

  8. Improving the Lieb-Robinson Bound for Long-Range Interactions

    NASA Astrophysics Data System (ADS)

    Matsuta, Takuro; Koma, Tohru; Nakamura, Shu

    2017-02-01

    We improve the Lieb-Robinson bound for a wide class of quantum many-body systems with long-range interactions decaying by power law. As an application, we show that the group velocity of information propagation grows by power law in time for such systems, whereas systems with short-range interactions exhibit a finite group velocity as shown by Lieb and Robinson.

  9. AN ANALYSIS OF THE RATIONALE AND PROCEDURES FOR LONG-RANGE PLANNING --FOUND IN SELECTED CORPORATE ENTERPRISES, GOVERNMENT AGENCIES OR DEPARTMENTS, AND SCHOOL SYSTEMS--WHICH ARE APPROPRIATE FOR EDUCATIONAL AND ADMINISTRATIVE PLANNING IN LOCAL SCHOOL SYSTEMS.

    ERIC Educational Resources Information Center

    RULIFFSON, WILLARD ADAMS

    THIS STUDY REVIEWS SOME OF THE CURRENT PLANNING PRACTICES IN SCHOOL SYSTEMS WHICH ARE CONSIDERED TO BE ALREADY INVOLVED IN LONG-RANGE PLANNING, AND DESCRIBES FURTHER LONG-RANGE TECHNIQUES WHICH COULD BE ADAPTED FOR SCHOOL SYSTEMS FROM CURRENT CORPORATE AND GOVERNMENTAL PLANNING PROCEDURES. INDIVIDUAL INTERVIEWS WERE CONDUCTED WITH SELECTED…

  10. Temperature offset control system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fried, M.

    1987-07-28

    This patent describes a temperature offset control system for controlling the operation of both heating and air conditioning systems simultaneously contained within the same premises each of which is set by local thermostats to operate at an appropriate temperature, the offset control system comprising: a central control station having means for presetting an offset temperature range, means for sensing the temperature at a central location, means for comparing the sensed temperature with the offset temperature range, means responsive to the comparison for producing a control signal indicative of whether the sensed temperature is within the offset temperature range or beyondmore » the offset temperature range, and means for transmitting the control signal onto the standard energy lines servicing the premises; and a receiving station respectively associated with each heating and air conditioning system, the receiving stations each comprising means for receiving the same transmitted control signal from the energy lines, and switch means for controlling the energization of the respective system in response to the received control signal. The heating systems and associated local thermostat are disabled by the control signal when the control signal originates from a sensed temperature above the lower end of the offset temperature range. The air conditioning systems and associated thermostats are disabled by the same control signal when the control signal originates from a sensed temperature below the upper end of the offset temperature range.« less

  11. Range Information Systems Management (RISM) Phase 1 Report

    NASA Technical Reports Server (NTRS)

    Bastin, Gary L.; Harris, William G.; Nelson, Richard A.

    2002-01-01

    RISM investigated alternative approaches, technologies, and communication network architectures to facilitate building the Spaceports and Ranges of the future. RISM started by document most existing US ranges and their capabilities. In parallel, RISM obtained inputs from the following: 1) NASA and NASA-contractor engineers and managers, and; 2) Aerospace leaders from Government, Academia, and Industry, participating through the Space Based Range Distributed System Working Group (SBRDSWG), many of whom are also; 3) Members of the Advanced Range Technology Working Group (ARTWG) subgroups, and; 4) Members of the Advanced Spaceport Technology Working Group (ASTWG). These diverse inputs helped to envision advanced technologies for implementing future Ranges and Range systems that builds on today s cabled and wireless legacy infrastructures while seamlessly integrating both today s emerging and tomorrow s building-block communication techniques. The fundamental key is to envision a transition to a Space Based Range Distributed Subsystem. The enabling concept is to identify the specific needs of Range users that can be solved through applying emerging communication tech

  12. Real-Time Adaptive Control of a Magnetic Levitation System with a Large Range of Load Disturbance.

    PubMed

    Zhang, Zhizhou; Li, Xiaolong

    2018-05-11

    In an idle light-load or a full-load condition, the change of the load mass of a suspension system is very significant. If the control parameters of conventional control methods remain unchanged, the suspension performance of the control system deteriorates rapidly or even loses stability when the load mass changes in a large range. In this paper, a real-time adaptive control method for a magnetic levitation system with large range of mass changes is proposed. First, the suspension control system model of the maglev train is built up, and the stability of the closed-loop system is analyzed. Then, a fast inner current-loop is used to simplify the design of the suspension control system, and an adaptive control method is put forward to ensure that the system is still in a stable state when the load mass varies in a wide range. Simulations and experiments show that when the load mass of the maglev system varies greatly, the adaptive control method is effective to suspend the system stably with a given displacement.

  13. Real-Time Adaptive Control of a Magnetic Levitation System with a Large Range of Load Disturbance

    PubMed Central

    Zhang, Zhizhou; Li, Xiaolong

    2018-01-01

    In an idle light-load or a full-load condition, the change of the load mass of a suspension system is very significant. If the control parameters of conventional control methods remain unchanged, the suspension performance of the control system deteriorates rapidly or even loses stability when the load mass changes in a large range. In this paper, a real-time adaptive control method for a magnetic levitation system with large range of mass changes is proposed. First, the suspension control system model of the maglev train is built up, and the stability of the closed-loop system is analyzed. Then, a fast inner current-loop is used to simplify the design of the suspension control system, and an adaptive control method is put forward to ensure that the system is still in a stable state when the load mass varies in a wide range. Simulations and experiments show that when the load mass of the maglev system varies greatly, the adaptive control method is effective to suspend the system stably with a given displacement. PMID:29751610

  14. JPL self pulsed laser surface measurement system development. [large space deployed antenna structures

    NASA Technical Reports Server (NTRS)

    Berdahl, M.

    1980-01-01

    The use of a self pulsed laser system for accurately describing the surface shape of large space deployed antenna structures was evaluated. Tests with a breadboard system verified functional operation with short time resolution on the order of .2 mm, nonambiguous ranging, and a maximum range capability on the order of 150 m. The projected capability of the system is resolution of less than .1 mm over a reasonable time period and a range extension to over 300 m.

  15. Doppler and range determination for deep space vehicles using active optical transponders.

    PubMed

    Kinman, P W; Gagliardi, R M

    1988-11-01

    This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.

  16. Doppler and range determination for deep space vehicles using active optical transponders

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Gagliardi, Robert M.

    1988-01-01

    This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.

  17. Fort Knox, KY Containment Berm Unit Installation

    DTIC Science & Technology

    2013-02-01

    There is interest from the range community in establishing a sustainable, closed loop small arms firing range (SAFR) bullet impact system or Containment... system . The metals from the bullets will be retained, stabilized, in the berm material with the addition of proper amendments. Following sufficient...replaced or placed back in the connex. This provides a closed loop containment system for sustainable range training purposes. The Containment Berm

  18. Precision Strike 2008 Summer Forum

    DTIC Science & Technology

    2008-01-11

    extended ranges, 360--mounted and dismounted Technical fire direction and limited tactical fire direction on all delivery systems Delivery systems that...can rapidly emplace/displace with high rates of fire Accurate on demand, meteorological data to delivery system ranges All munitions with less than 50M...CEP at all ranges Munitions that provide a variety of effects in any environment To achieve this, Field Artillery needs these “enablers” Target

  19. Task path planning, scheduling and learning for free-ranging robot systems

    NASA Technical Reports Server (NTRS)

    Wakefield, G. Steve

    1987-01-01

    The development of robotics applications for space operations is often restricted by the limited movement available to guided robots. Free ranging robots can offer greater flexibility than physically guided robots in these applications. Presented here is an object oriented approach to path planning and task scheduling for free-ranging robots that allows the dynamic determination of paths based on the current environment. The system also provides task learning for repetitive jobs. This approach provides a basis for the design of free-ranging robot systems which are adaptable to various environments and tasks.

  20. Development of vacuum ultraviolet absorption spectroscopy system for wide measurement range of number density using a dual-tube inductively coupled plasma light source

    NASA Astrophysics Data System (ADS)

    Kuwahara, Akira; Matsui, Makoto; Yamagiwa, Yoshiki

    2012-12-01

    A vacuum ultraviolet absorption spectroscopy system for a wide measurement range of atomic number densities is developed. Dual-tube inductively coupled plasma was used as a light source. The probe beam profile was optimized for the target number density range by changing the mass flow rate of the inner and outer tubes. This system was verified using cold xenon gas. As a result, the measurement number density range was extended from the conventional two orders to five orders of magnitude.

  1. Synthesis and analysis of precise spaceborne laser ranging systems, volume 2. [Spacelab payload

    NASA Technical Reports Server (NTRS)

    Paddon, E. A.

    1978-01-01

    The performance capabilities of specific shuttle-based laser ranging systems were evaluated, and interface and support requirements were determined. The preliminary design of a shuttle-borne laser ranging experiment developed as part of the Spacelab program is discussed.

  2. Isotope Brayton electric power system for the 500 to 2500 watt range.

    NASA Technical Reports Server (NTRS)

    Macosko, R. P.; Barna, G. J.; Block, H. B.; Ingle, B. D.

    1972-01-01

    An extensive study was conducted at the Lewis Research Center to evaluate an isotope Brayton electric power system for use in the 500 to 2500 W power range. The study emphasized overall system simplicity in order to reduce parasitic power losses and improve system reliability. The study included detailed parametric cycle analysis, conceptual component designs, and evaluation of system packaging. The study has resulted in the selection of a single-loop system (gas) with six major components including one rotating unit. Calculated net system efficiency varies from 23 to 28% over the power range. The use of the Pu-238 heat source being developed for the Multi-Hundred-Watt Radioisotope Thermoelectric Generator program was assumed.

  3. Remote sensing of atmospheric pressure and sea state using laser altimeters

    NASA Technical Reports Server (NTRS)

    Gardner, C. S.

    1985-01-01

    Short-pulse multicolor laser ranging systems are currently being developed for satellite ranging applications. These systems use Q-switched pulsed lasers and streak-tube cameras to provide timing accuracies approaching a few picoseconds. Satellite laser ranging systems have been used to evaluate many important geophysical phenomena such as fault motion, polar motion and solid earth tides, by measuring the orbital perturbations of retroreflector equipped satellites. Some existing operational systems provide range resolution approaching a few millimeters. There is currently considerable interest in adapting these highly accurate systems for use as airborne and satellite based altimeters. Potential applications include the measurement of sea state, ground topography and atmospheric pressure. This paper reviews recent progress in the development of multicolor laser altimeters for use in monitoring sea state and atmospheric pressure.

  4. Multi-beam range imager for autonomous operations

    NASA Technical Reports Server (NTRS)

    Marzwell, Neville I.; Lee, H. Sang; Ramaswami, R.

    1993-01-01

    For space operations from the Space Station Freedom the real time range imager will be very valuable in terms of refuelling, docking as well as space exploration operations. For these applications as well as many other robotics and remote ranging applications, a small potable, power efficient, robust range imager capable of a few tens of km ranging with 10 cm accuracy is needed. The system developed is based on a well known pseudo-random modulation technique applied to a laser transmitter combined with a novel range resolution enhancement technique. In this technique, the transmitter is modulated by a relatively low frequency of an order of a few MHz to enhance the signal to noise ratio and to ease the stringent systems engineering requirements while accomplishing a very high resolution. The desired resolution cannot easily be attained by other conventional approaches. The engineering model of the system is being designed to obtain better than 10 cm range accuracy simply by implementing a high precision clock circuit. In this paper we present the principle of the pseudo-random noise (PN) lidar system and the results of the proof of experiment.

  5. Laser-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

    NASA Technical Reports Server (NTRS)

    Wells, Dennis L. (Inventor); Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1995-01-01

    The invention relates generally to systems for determining the range of an object from a reference point and, in one embodiment, to laser-directed ranging systems useful in telerobotics applications. Digital processing techniques are employed which minimize the complexity and cost of the hardware and software for processing range calculations, thereby enhancing the commercial attractiveness of the system for use in relatively low-cost robotic systems. The system includes a video camera for generating images of the target, image digitizing circuitry, and an associated frame grabber circuit. The circuit first captures one of the pairs of stereo video images of the target, and then captures a second video image of the target as it is partly illuminated by the light beam, suitably generated by a laser. The two video images, taken sufficiently close together in time to minimize camera and scene motion, are converted to digital images and then compared. Common pixels are eliminated, leaving only a digital image of the laser-illuminated spot on the target. Mw centroid of the laser illuminated spot is dm obtained and compared with a predetermined reference point, predetermined by design or calibration, which represents the coordinate at the focal plane of the laser illumination at infinite range. Preferably, the laser and camera are mounted on a servo-driven platform which can be oriented to direct the camera and the laser toward the target. In one embodiment the platform is positioned in response to movement of the operator's head. Position and orientation sensors are used to monitor head movement. The disparity between the digital image of the laser spot and the reference point is calculated for determining range to the target. Commercial applications for the system relate to active range-determination systems, such as those used with robotic systems in which it is necessary to determine the, range to a workpiece or object to be grasped or acted upon by a robot arm end-effector in response to commands generated by an operator. In one embodiment, the system provides a real-time image of the target for the operator as the robot approaches the object. The system is also adapted for use in virtual reality systems in which a remote object or workpiece is to be acted upon by a remote robot arm or other mechanism controlled by an operator.

  6. Collector Size or Range Independence of SNR in Fixed-Focus Remote Raman Spectrometry.

    PubMed

    Hirschfeld, T

    1974-07-01

    When sensitivity allows, remote Raman spectrometers can be operated at a fixed focus with purely electronic (easily multiplexable) range gating. To keep the background small, the system etendue must be minimized. For a maximum range larger than the hyperfocal one, this is done by focusing the system at roughly twice the minimum range at which etendue matching is still required. Under these conditions the etendue varies as the fourth power of the collector diameter, causing the background shot noise to vary as its square. As the signal also varies with the same power, and background noise is usually limiting in this type instrument, the SNR becomes independent of the collector size. Below this minimum etendue-matched range, the transmission at the limiting aperture grows with the square of the range, canceling the inverse square loss of signal with range. The SNR is thus range independent below the minimum etendue matched range and collector size independent above it, with the location of transition being determined by the system etendue and collector diameter. The range of validity of these outrageousstatements is discussed.

  7. Middle Range Sea Ice Prediction System of Voyage Environmental Information System in Arctic Sea Route

    NASA Astrophysics Data System (ADS)

    Lim, H. S.

    2017-12-01

    Due to global warming, the sea ice in the Arctic Ocean is melting dramatically in summer, which is providing a new opportunity to exploit the Northern Sea Route (NSR) connecting Asia and Europe ship route. Recent increases in logistics transportation through NSR and resource development reveal the possible threats of marine pollution and marine transportation accidents without real-time navigation system. To develop a safe Voyage Environmental Information System (VEIS) for vessels operating, the Korea Institute of Ocean Science and Technology (KIOST) which is supported by the Ministry of Oceans and Fisheries, Korea has initiated the development of short-term and middle range prediction system for the sea ice concentration (SIC) and sea ice thickness (SIT) in NSR since 2014. The sea ice prediction system of VEIS consists of AMSR2 satellite composite images (a day), short-term (a week) prediction system, and middle range (a month) prediction system using a statistical method with re-analysis data (TOPAZ) and short-term predicted model data. In this study, the middle range prediction system for the SIC and SIT in NSR is calibrated with another middle range predicted atmospheric and oceanic data (NOAA CFSv2). The system predicts one month SIC and SIT on a daily basis, as validated with dynamic composite SIC data extracted from AMSR2 L2 satellite images.

  8. Surprises from quenches in long-range-interacting systems: temperature inversion and cooling

    NASA Astrophysics Data System (ADS)

    Gupta, Shamik; Casetti, Lapo

    2016-10-01

    What happens when one of the parameters governing the dynamics of a long-range interacting system of particles in thermal equilibrium is abruptly changed (quenched) to a different value? While a short-range system, under the same conditions, will relax in time to a new thermal equilibrium with a uniform temperature across the system, a long-range system shows a fast relaxation to a non-equilibrium quasistationary state (QSS). The lifetime of such an off-equilibrium state diverges with the system size, and the temperature is non-uniform across the system. Quite surprisingly, the density profile in the QSS obtained after the quench is anticorrelated with the temperature profile in space, thus exhibiting the phenomenon of temperature inversion: denser regions are colder than sparser ones. We illustrate with extensive molecular dynamics simulations the ubiquity of this scenario in a prototypical long-range interacting system subject to a variety of quenching protocols, and in a model that mimics an experimental setup of atoms interacting with light in an optical cavity. We further demonstrate how a procedure of iterative quenching combined with filtering out the high-energy particles in the system may be employed to cool the system. Temperature inversion is observed in nature in some astrophysical settings; our results imply that such a phenomenon should be observable, and could even be exploitable to advantage, also in controlled laboratory experiments.

  9. Single photon ranging system using two wavelengths laser and analysis of precision

    NASA Astrophysics Data System (ADS)

    Chen, Yunfei; He, Weiji; Miao, Zhuang; Gu, Guohua; Chen, Qian

    2013-09-01

    The laser ranging system based on time correlation single photon counting technology and single photon detector has the feature of high precision and low emergent energy etc. In this paper, we established a single photon laser ranging system that use the supercontinuum laser as light source, and two wavelengths (532nm and 830nm) of echo signal as the stop signal. We propose a new method that is capable to improve the single photon ranging system performance. The method is implemented by using two single-photon detectors to receive respectively the two different wavelength signals at the same time. We extracted the firings of the two detectors triggered by the same laser pulse at the same time and then took mean time of the two firings as the combined detection time-of-flight. The detection by two channels using two wavelengths will effectively improve the detection precision and decrease the false alarm probability. Finally, an experimental single photon ranging system was established. Through a lot of experiments, we got the system precision using both single and two wavelengths and verified the effectiveness of the method.

  10. Soliton microcomb range measurement

    NASA Astrophysics Data System (ADS)

    Suh, Myoung-Gyun; Vahala, Kerry J.

    2018-02-01

    Laser-based range measurement systems are important in many application areas, including autonomous vehicles, robotics, manufacturing, formation flying of satellites, and basic science. Coherent laser ranging systems using dual-frequency combs provide an unprecedented combination of long range, high precision, and fast update rate. We report dual-comb distance measurement using chip-based soliton microcombs. A single pump laser was used to generate dual-frequency combs within a single microresonator as counterpropagating solitons. We demonstrated time-of-flight measurement with 200-nanometer precision at an averaging time of 500 milliseconds within a range ambiguity of 16 millimeters. Measurements at distances up to 25 meters with much lower precision were also performed. Our chip-based source is an important step toward miniature dual-comb laser ranging systems that are suitable for photonic integration.

  11. The Kalman Filter Applied to Process Range Data of the Cubic Model 40 Autotape System

    DTIC Science & Technology

    1976-12-01

    the unit to be tracked, two responders operated at two different shore sites and the associated antenna/RF assemblies. Required support systems include...where the range arcs are orthogonal. Figure 9 diagrams error contours which are actually the locii of constant MPE for two particular responder sites ...ranges simultaneously, once per second, the ranges being those between the Interrogator and each of the responders . The ranges are computed from the

  12. Ultra-wide Range Gamma Detector System for Search and Locate Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Odell, D. Mackenzie Odell; Harpring, Larry J.; Moore, Frank S. Jr.

    2005-10-26

    Collecting debris samples following a nuclear event requires that operations be conducted from a considerable stand-off distance. An ultra-wide range gamma detector system has been constructed to accomplish both long range radiation search and close range hot sample collection functions. Constructed and tested on a REMOTEC Andros platform, the system has demonstrated reliable operation over six orders of magnitude of gamma dose from 100's of uR/hr to over 100 R/hr. Functional elements include a remotely controlled variable collimator assembly, a NaI(Tl)/photomultiplier tube detector, a proprietary digital radiation instrument, a coaxially mounted video camera, a digital compass, and both local andmore » remote control computers with a user interface designed for long range operations. Long range sensitivity and target location, as well as close range sample selection performance are presented.« less

  13. Coherent Doppler lidar for automated space vehicle rendezvous, stationkeeping and capture

    NASA Technical Reports Server (NTRS)

    Bilbro, James A.

    1991-01-01

    The inherent spatial resolution of laser radar makes ladar or lidar an attractive candidate for Automated Rendezvous and Capture application. Previous applications were based on incoherent lidar techniques, requiring retro-reflectors on the target vehicle. Technology improvements (reduced size, no cryogenic cooling requirement) have greatly enhanced the construction of coherent lidar systems. Coherent lidar permits the acquisition of non-cooperative targets at ranges that are limited by the detection capability rather than by the signal-to-noise ratio (SNR) requirements. The sensor can provide translational state information (range, velocity, and angle) by direct measurement and, when used with any array detector, also can provide attitude information by Doppler imaging techniques. Identification of the target is accomplished by scanning with a high pulse repetition frequency (dependent on the SNR). The system performance is independent of range and should not be constrained by sun angle. An initial effort to characterize a multi-element detection system has resulted in a system that is expected to work to a minimum range of 1 meter. The system size, weight and power requirements are dependent on the operating range; 10 km range requires a diameter of 3 centimeters with overall size at 3 x 3 x 15 to 30 cm, while 100 km range requires a 30 cm diameter.

  14. An investigation of errors and data processing techniques for an RF multilateration system. [position and velocity measurements of vertical takeoff aircraft during landing

    NASA Technical Reports Server (NTRS)

    Britt, C. L., Jr.

    1975-01-01

    The development of an RF Multilateration system to provide accurate position and velocity measurements during the approach and landing phase of Vertical Takeoff Aircraft operation is discussed. The system uses an angle-modulated ranging signal to provide both range and range rate measurements between an aircraft transponder and multiple ground stations. Range and range rate measurements are converted to coordinate measurements and the coordinate and coordinate rate information is transmitted by an integral data link to the aircraft. Data processing techniques are analyzed to show advantages and disadvantages. Error analyses are provided to permit a comparison of the various techniques.

  15. Atmospheric simulator and calibration system for remote sensing radiometers

    NASA Technical Reports Server (NTRS)

    Holland, J. A.

    1983-01-01

    A system for calibrating the MAPS (measurement of air pollution from satellites) instruments was developed. The design of the system provides a capability for simulating a broad range of radiant energy source temperatures and a broad range of atmospheric pressures, temperatures, and pollutant concentrations for a single slab atmosphere. The system design and the system operation are described.

  16. Guide to Synchronization of Video Systems to IRIG Timing

    DTIC Science & Technology

    1992-07-01

    and industry. 1-2 CHAPTER 2 SYNCHRONISATION Before delving into the details of synchronization , a review is needed of the reasons for synchronizing ... Synchronization of Video Systems to IRIG Timing Optical Systems Group Range Commanders Council White Sands Missile Range, NM 88002-5110 RCC Document 456-92 Range...This document addresses a broad field of video synchronization to IRIG timing with emphasis on color synchronization . This document deals with

  17. Miniaturized GPS/MEMS IMU integrated board

    NASA Technical Reports Server (NTRS)

    Lin, Ching-Fang (Inventor)

    2012-01-01

    This invention documents the efforts on the research and development of a miniaturized GPS/MEMS IMU integrated navigation system. A miniaturized GPS/MEMS IMU integrated navigation system is presented; Laser Dynamic Range Imager (LDRI) based alignment algorithm for space applications is discussed. Two navigation cameras are also included to measure the range and range rate which can be integrated into the GPS/MEMS IMU system to enhance the navigation solution.

  18. Dynamic Calibration and Verification Device of Measurement System for Dynamic Characteristic Coefficients of Sliding Bearing

    PubMed Central

    Chen, Runlin; Wei, Yangyang; Shi, Zhaoyang; Yuan, Xiaoyang

    2016-01-01

    The identification accuracy of dynamic characteristics coefficients is difficult to guarantee because of the errors of the measurement system itself. A novel dynamic calibration method of measurement system for dynamic characteristics coefficients is proposed in this paper to eliminate the errors of the measurement system itself. Compared with the calibration method of suspension quality, this novel calibration method is different because the verification device is a spring-mass system, which can simulate the dynamic characteristics of sliding bearing. The verification device is built, and the calibration experiment is implemented in a wide frequency range, in which the bearing stiffness is simulated by the disc springs. The experimental results show that the amplitude errors of this measurement system are small in the frequency range of 10 Hz–100 Hz, and the phase errors increase along with the increasing of frequency. It is preliminarily verified by the simulated experiment of dynamic characteristics coefficients identification in the frequency range of 10 Hz–30 Hz that the calibration data in this frequency range can support the dynamic characteristics test of sliding bearing in this frequency range well. The bearing experiments in greater frequency ranges need higher manufacturing and installation precision of calibration device. Besides, the processes of calibration experiments should be improved. PMID:27483283

  19. Experiments and error analysis of laser ranging based on frequency-sweep polarization modulation

    NASA Astrophysics Data System (ADS)

    Gao, Shuyuan; Ji, Rongyi; Li, Yao; Cheng, Zhi; Zhou, Weihu

    2016-11-01

    Frequency-sweep polarization modulation ranging uses a polarization-modulated laser beam to determine the distance to the target, the modulation frequency is swept and frequency values are measured when transmitted and received signals are in phase, thus the distance can be calculated through these values. This method gets much higher theoretical measuring accuracy than phase difference method because of the prevention of phase measurement. However, actual accuracy of the system is limited since additional phase retardation occurs in the measuring optical path when optical elements are imperfectly processed and installed. In this paper, working principle of frequency sweep polarization modulation ranging method is analyzed, transmission model of polarization state in light path is built based on the theory of Jones Matrix, additional phase retardation of λ/4 wave plate and PBS, their impact on measuring performance is analyzed. Theoretical results show that wave plate's azimuth error dominates the limitation of ranging accuracy. According to the system design index, element tolerance and error correcting method of system is proposed, ranging system is built and ranging experiment is performed. Experiential results show that with proposed tolerance, the system can satisfy the accuracy requirement. The present work has a guide value for further research about system design and error distribution.

  20. Radiation dose and magnification in pelvic X-ray: EOS™ imaging system versus plain radiographs.

    PubMed

    Chiron, P; Demoulin, L; Wytrykowski, K; Cavaignac, E; Reina, N; Murgier, J

    2017-12-01

    In plain pelvic X-ray, magnification makes measurement unreliable. The EOS™ (EOS Imaging, Paris France) imaging system is reputed to reproduce patient anatomy exactly, with a lower radiation dose. This, however, has not been assessed according to patient weight, although both magnification and irradiation are known to vary with weight. We therefore conducted a prospective comparative study, to compare: (1) image magnification and (2) radiation dose between the EOS imaging system and plain X-ray. The EOS imaging system reproduces patient anatomy exactly, regardless of weight, unlike plain X-ray. A single-center comparative study of plain pelvic X-ray and 2D EOS radiography was performed in 183 patients: 186 arthroplasties; 104 male, 81 female; mean age 61.3±13.7years (range, 24-87years). Magnification and radiation dose (dose-area product [DAP]) were compared between the two systems in 186 hips in patients with a mean body-mass index (BMI) of 27.1±5.3kg/m 2 (range, 17.6-42.3kg/m 2 ), including 7 with morbid obesity. Mean magnification was zero using the EOS system, regardless of patient weight, compared to 1.15±0.05 (range, 1-1.32) on plain X-ray (P<10 -5 ). In patients with BMI<25, mean magnification on plain X-ray was 1.15±0.05 (range, 1-1.25) and, in patients with morbid obesity, 1.22±0.06 (range, 1.18-1.32). The mean radiation dose was 8.19±2.63dGy/cm 2 (range, 1.77-14.24) with the EOS system, versus 19.38±12.37dGy/cm 2 (range, 4.77-81.75) with plain X-ray (P<10 -4 ). For BMI >40, mean radiation dose was 9.36±2.57dGy/cm 2 (range, 7.4-14.2) with the EOS system, versus 44.76±22.21 (range, 25.2-81.7) with plain X-ray. Radiation dose increased by 0.20dGy with each extra BMI point for the EOS system, versus 0.74dGy for plain X-ray. Magnification did not vary with patient weight using the EOS system, unlike plain X-ray, and radiation dose was 2.5-fold lower. 3, prospective case-control study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Panama Canal Fog Navigation Study : Candidate System Definition

    DOT National Transportation Integrated Search

    1984-01-01

    A candidate system for solving fog navigation problems in the Panama Canal is defined. The vessel monitoring subsystem is a shore-based, all-weather, precision ranging system with ranging accuracies of 9 feet (2 standard deviations, 95 percent).

  2. The airborne laser ranging system, its capabilities and applications

    NASA Technical Reports Server (NTRS)

    Kahn, W. D.; Degnan, J. J.; Englar, T. S., Jr.

    1982-01-01

    The airborne laser ranging system is a multibeam short pulse laser ranging system on board an aircraft. It simultaneously measures the distances between the aircraft and six laser retroreflectors (targets) deployed on the Earth's surface. The system can interrogate over 100 targets distributed over an area of 25,000 sq, kilometers in a matter of hours. Potentially, a total of 1.3 million individual range measurements can be made in a six hour flight. The precision of these range measurements is approximately + or - 1 cm. These measurements are used in procedure which is basically an extension of trilateration techniques to derive the intersite vector between the laser ground targets. By repeating the estimation of the intersite vector, strain and strain rate errors can be estimated. These quantities are essential for crustal dynamic studies which include determination and monitoring of regional strain in the vicinity of active fault zones, land subsidence, and edifice building preceding volcanic eruptions.

  3. A Flight Control System for Small Unmanned Aerial Vehicle

    NASA Astrophysics Data System (ADS)

    Tunik, A. A.; Nadsadnaya, O. I.

    2018-03-01

    The program adaptation of the controller for the flight control system (FCS) of an unmanned aerial vehicle (UAV) is considered. Linearized flight dynamic models depend mainly on the true airspeed of the UAV, which is measured by the onboard air data system. This enables its use for program adaptation of the FCS over the full range of altitudes and velocities, which define the flight operating range. FCS with program adaptation, based on static feedback (SF), is selected. The SF parameters for every sub-range of the true airspeed are determined using the linear matrix inequality approach in the case of discrete systems for synthesis of a suboptimal robust H ∞-controller. The use of the Lagrange interpolation between true airspeed sub-ranges provides continuous adaptation. The efficiency of the proposed approach is shown against an example of the heading stabilization system.

  4. Structural and lithographic study of northern coast ranges and Sacramento Valley, California

    NASA Technical Reports Server (NTRS)

    Rich, E. I. (Principal Investigator)

    1973-01-01

    The author has identified the following significant results. The analysis of the ERTS data has disclosed three potentially important linear systems within the northern coast ranges and Sacramento Valley, California. A preliminary geomorphic analysis of the northern coast ranges discloses that the geomorphic characteristics of the area underlain by the Coastal system are much different from those associated with the Central system in the core of the Coast Ranges. Within the Coastal system, or Coastal belt, the drainage networks are moderately fine-textured and have moderately high density. The area associated with the Central system seems to be underlain by an heterogeneous assemblage of rock types which vary in their resistance to erosion. The boundary between the Coastal and Central geomorphic regions is poorly defined and, in a few places, the two regions can be separated only approximately.

  5. Comparison of the clinical outcomes after total knee arthroplasty with the LCS rotating platform mobile bearing knee system and the PFC Sigma RP-F mobile bearing knee system.

    PubMed

    Kwak, Ju-Yeong; Jeong, Jae-Heon; Lee, Sang-Hak; Jung, Ho-Joong; Jung, Young-Bok

    2012-12-01

    We compared clinical outcomes after total knee arthroplasty with the Low Contact Stress (LCS) rotating platform mobile bearing knee system and the Press Fit Condylar Sigma rotating platform high flexion (PFC Sigma RP-F) mobile bearing knee system. Fifty cases of total knee arthroplasty were performed with the PFC Sigma RP-F mobile bearing knee system and sixty-one cases were performed with the LCS mobile bearing total knee arthroplasty. The average duration of follow-up was 2.9 years. The mean Hospital for Special Surgery (HSS) knee score was 62.1 (range, 52 to 75) in the LCS group and 61.9 (range, 50 to 74) in the Sigma RP-F group preoperatively, and 90.1 (range, 84 to 100) in the LCS group and 89.8 (range, 83 to 100) in the Sigma RP-F group at the final follow-up. The mean preoperative flexion contracture was 6.7° (range, 0° to 10°) in the LCS group and 9.3° (range, 0° to 15°) in the Sigma RP-F group preoperatively. The mean range of motion was 124.6° (range, 105° to 150°) in the LCS group and 126.1° (range, 104° to 145°) in the Sigma RP-F group at the final follow-up. After a minimum duration of follow-up of two years, we found no significant differences between the two groups with regard to the range of knee motion or the clinical or radiographic results.

  6. Loosely Coupled GPS-Aided Inertial Navigation System for Range Safety

    NASA Technical Reports Server (NTRS)

    Heatwole, Scott; Lanzi, Raymond J.

    2010-01-01

    The Autonomous Flight Safety System (AFSS) aims to replace the human element of range safety operations, as well as reduce reliance on expensive, downrange assets for launches of expendable launch vehicles (ELVs). The system consists of multiple navigation sensors and flight computers that provide a highly reliable platform. It is designed to ensure that single-event failures in a flight computer or sensor will not bring down the whole system. The flight computer uses a rules-based structure derived from range safety requirements to make decisions whether or not to destroy the rocket.

  7. University of Hawaii Lure Observatory. [lunar laser ranging system construction

    NASA Technical Reports Server (NTRS)

    Carter, W. E.; Williams, J. D.

    1973-01-01

    The University of Hawaii's Institute for Astronomy is currently constructing a lunar laser ranging observatory at the 3050-meter summit of Mt. Haleakala, Hawaii. The Nd YAG laser system to be employed provides three pulses per second, each pulse being approximately 200 picoseconds in duration. The energy contained in one pulse at 5320 A lies in the range from 250 to 350 millijoules. Details of observatory construction are provided together with transmitter design data and information concerning the lunastat, the feed telescope, the relative pointing system, the receiver, and the event timer system.

  8. A web-based communication system for integrated care in cerebral palsy: design features, technical feasibility and usability.

    PubMed

    Gulmans, Jitske; Vollenbroek-Hutten, Miriam M R; Visser, Jacqueline J W; Nijeweme-d'Hollosy, Wendy Oude; van Gemert-Pijnen, J E W C Lisette; van Harten, Wim H

    2010-01-01

    We developed a secure, web-based system for parent-professional and inter-professional communication. The aim was to improve communication in the care of children with cerebral palsy. We conducted a six-month trial of the system in three Dutch health-care regions. The participants were the parents of 30 cerebral palsy patients and 120 professional staff involved in their care. Information about system usage was extracted from the system's database. The experience of the parents and professionals was evaluated by a questionnaire after six months. The system proved to be technically robust and reliable. A total of 21 parents (70%) and 66 professionals (55%) used the system. The parents submitted 111 questions and 59 responses, with a mean of 5 questions (range 1-17) and 3 responses (range 1-9) per parent. The professionals submitted 79 questions and 237 responses, with a mean of 2 questions (range 1-8) and 4 responses (range 1-23) per professional. Most parents (95%) and some professionals (30%) reported value in using the system, which ranged from efficiency and accessibility to flexibility and transparency. The web-based communication system was technically feasible and produced improved parent-professional and inter-professional communication. It may be especially valuable if frequent interventions or consultations about a child's care are required, involving complex care networks of different professionals and organisations.

  9. The spatial ecology of free-ranging domestic pigs (Sus scrofa) in western Kenya.

    PubMed

    Thomas, Lian F; de Glanville, William A; Cook, Elizabeth A; Fèvre, Eric M

    2013-03-07

    In many parts of the developing world, pigs are kept under low-input systems where they roam freely to scavenge food. These systems allow poor farmers the opportunity to enter into livestock keeping without large capital investments. This, combined with a growing demand for pork, especially in urban areas, has led to an increase in the number of small-holder farmers keeping free range pigs as a commercial enterprise. Despite the benefits which pig production can bring to a household, keeping pigs under a free range system increases the risk of the pig acquiring diseases, either production-limiting or zoonotic in nature. This study used Global Positioning System (GPS) technology to track free range domestic pigs in rural western Kenya, in order to understand their movement patterns and interactions with elements of the peri-domestic environment. We found that these pigs travel an average of 4,340 m in a 12 hr period and had a mean home range of 10,343 m(2) (range 2,937-32,759 m(2)) within which the core utilisation distribution was found to be 964 m(2) (range 246-3,289 m(2)) with pigs spending on average 47% of their time outside their homestead of origin. These are the first data available on the home range of domestic pigs kept under a free range system: the data show that pigs in these systems spend much of their time scavenging outside their homesteads, suggesting that these pigs may be exposed to infectious agents over a wide area. Control policies for diseases such as Taenia solium, Trypanosomiasis, Trichinellosis, Toxoplasmosis or African Swine Fever therefore require a community-wide focus and pig farmers require education on the inherent risks of keeping pigs under a free range system. The work presented here will enable future research to incorporate movement data into studies of disease transmission, for example for the understanding of transmission of African Swine Fever between individuals, or in relation to the life-cycle of parasites including Taenia solium.

  10. The spatial ecology of free-ranging domestic pigs (Sus scrofa) in western Kenya

    PubMed Central

    2013-01-01

    Background In many parts of the developing world, pigs are kept under low-input systems where they roam freely to scavenge food. These systems allow poor farmers the opportunity to enter into livestock keeping without large capital investments. This, combined with a growing demand for pork, especially in urban areas, has led to an increase in the number of small-holder farmers keeping free range pigs as a commercial enterprise. Despite the benefits which pig production can bring to a household, keeping pigs under a free range system increases the risk of the pig acquiring diseases, either production-limiting or zoonotic in nature. This study used Global Positioning System (GPS) technology to track free range domestic pigs in rural western Kenya, in order to understand their movement patterns and interactions with elements of the peri-domestic environment. Results We found that these pigs travel an average of 4,340 m in a 12 hr period and had a mean home range of 10,343 m2 (range 2,937–32,759 m2) within which the core utilisation distribution was found to be 964 m2 (range 246–3,289 m2) with pigs spending on average 47% of their time outside their homestead of origin. Conclusion These are the first data available on the home range of domestic pigs kept under a free range system: the data show that pigs in these systems spend much of their time scavenging outside their homesteads, suggesting that these pigs may be exposed to infectious agents over a wide area. Control policies for diseases such as Taenia solium, Trypanosomiasis, Trichinellosis, Toxoplasmosis or African Swine Fever therefore require a community-wide focus and pig farmers require education on the inherent risks of keeping pigs under a free range system. The work presented here will enable future research to incorporate movement data into studies of disease transmission, for example for the understanding of transmission of African Swine Fever between individuals, or in relation to the life-cycle of parasites including Taenia solium. PMID:23497587

  11. Laser range profiling for small target recognition

    NASA Astrophysics Data System (ADS)

    Steinvall, Ove; Tulldahl, Michael

    2016-05-01

    The detection and classification of small surface and airborne targets at long ranges is a growing need for naval security. Long range ID or ID at closer range of small targets has its limitations in imaging due to the demand on very high transverse sensor resolution. It is therefore motivated to look for 1D laser techniques for target ID. These include vibrometry, and laser range profiling. Vibrometry can give good results but is also sensitive to certain vibrating parts on the target being in the field of view. Laser range profiling is attractive because the maximum range can be substantial, especially for a small laser beam width. A range profiler can also be used in a scanning mode to detect targets within a certain sector. The same laser can also be used for active imaging when the target comes closer and is angular resolved. The present paper will show both experimental and simulated results for laser range profiling of small boats out to 6-7 km range and a UAV mockup at close range (1.3 km). We obtained good results with the profiling system both for target detection and recognition. Comparison of experimental and simulated range waveforms based on CAD models of the target support the idea of having a profiling system as a first recognition sensor and thus narrowing the search space for the automatic target recognition based on imaging at close ranges. The naval experiments took place in the Baltic Sea with many other active and passive EO sensors beside the profiling system. Discussion of data fusion between laser profiling and imaging systems will be given. The UAV experiments were made from the rooftop laboratory at FOI.

  12. Largo hot water system long range thermal performance test report, addendum

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency, temperature distribution, and system performance degradation.

  13. ASTP ranging system mathematical model

    NASA Technical Reports Server (NTRS)

    Ellis, M. R.; Robinson, L. H.

    1973-01-01

    A mathematical model is presented of the VHF ranging system to analyze the performance of the Apollo-Soyuz test project (ASTP). The system was adapted for use in the ASTP. The ranging system mathematical model is presented in block diagram form, and a brief description of the overall model is also included. A procedure for implementing the math model is presented along with a discussion of the validation of the math model and the overall summary and conclusions of the study effort. Detailed appendices of the five study tasks are presented: early late gate model development, unlock probability development, system error model development, probability of acquisition and model development, and math model validation testing.

  14. Scaling functions for systems with finite range of interaction

    NASA Astrophysics Data System (ADS)

    Sampaio-Filho, C. I. N.; Moreira, F. G. B.

    2013-09-01

    We present a numerical determination of the scaling functions of the magnetization, the susceptibility, and the Binder's cumulant for two nonequilibrium model systems with varying range of interactions. We consider Monte Carlo simulations of the block voter model (BVM) on square lattices and of the majority-vote model (MVM) on random graphs. In both cases, the satisfactory data collapse obtained for several system sizes and interaction ranges supports the hypothesis that these functions are universal. Our analysis yields an accurate estimation of the long-range exponents, which govern the decay of the critical amplitudes with the range of interaction, and is consistent with the assumption that the static exponents are Ising-like for the BVM and classical for the MVM.

  15. Research on range-gated laser active imaging seeker

    NASA Astrophysics Data System (ADS)

    You, Mu; Wang, PengHui; Tan, DongJie

    2013-09-01

    Compared with other imaging methods such as millimeter wave imaging, infrared imaging and visible light imaging, laser imaging provides both a 2-D array of reflected intensity data as well as 2-D array of range data, which is the most important data for use in autonomous target acquisition .In terms of application, it can be widely used in military fields such as radar, guidance and fuse. In this paper, we present a laser active imaging seeker system based on range-gated laser transmitter and sensor technology .The seeker system presented here consist of two important part, one is laser image system, which uses a negative lens to diverge the light from a pulse laser to flood illuminate a target, return light is collected by a camera lens, each laser pulse triggers the camera delay and shutter. The other is stabilization gimbals, which is designed to be a rotatable structure both in azimuth and elevation angles. The laser image system consists of transmitter and receiver. The transmitter is based on diode pumped solid-state lasers that are passively Q-switched at 532nm wavelength. A visible wavelength was chosen because the receiver uses a Gen III image intensifier tube with a spectral sensitivity limited to wavelengths less than 900nm.The receiver is image intensifier tube's micro channel plate coupled into high sensitivity charge coupled device camera. The image has been taken at range over one kilometer and can be taken at much longer range in better weather. Image frame frequency can be changed according to requirement of guidance with modifiable range gate, The instantaneous field of views of the system was found to be 2×2 deg. Since completion of system integration, the seeker system has gone through a series of tests both in the lab and in the outdoor field. Two different kinds of buildings have been chosen as target, which is located at range from 200m up to 1000m.To simulate dynamic process of range change between missile and target, the seeker system has been placed on the truck vehicle running along the road in an expected speed. The test result shows qualified image and good performance of the seeker system.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barstow, Del R; Patlolla, Dilip Reddy; Mann, Christopher J

    Abstract The data captured by existing standoff biometric systems typically has lower biometric recognition performance than their close range counterparts due to imaging challenges, pose challenges, and other factors. To assist in overcoming these limitations systems typically perform in a multi-modal capacity such as Honeywell s Combined Face and Iris (CFAIRS) [21] system. While this improves the systems performance, standoff systems have yet to be proven as accurate as their close range equivalents. We will present a standoff system capable of operating up to 7 meters in range. Unlike many systems such as the CFAIRS our system captures high qualitymore » 12 MP video allowing for a multi-sample as well as multi-modal comparison. We found that for standoff systems multi-sample improved performance more than multi-modal. For a small test group of 50 subjects we were able to achieve 100% rank one recognition performance with our system.« less

  17. Servomotor and Controller Having Large Dynamic Range

    NASA Technical Reports Server (NTRS)

    Alhorn, Dean C.; Howard, David E.; Smith, Dennis A.; Dutton, Ken; Paulson, M. Scott

    2007-01-01

    A recently developed micro-commanding rotational-position-control system offers advantages of less mechanical complexity, less susceptibility to mechanical resonances, less power demand, less bulk, less weight, and lower cost, relative to prior rotational-position-control systems based on stepping motors and gear drives. This system includes a digital-signal- processor (DSP)-based electronic controller, plus a shaft-angle resolver and a servomotor mounted on the same shaft. Heretofore, micro-stepping has usually been associated with stepping motors, but in this system, the servomotor is micro-commanded in response to rotational-position feedback from the shaft-angle resolver. The shaft-angle resolver is of a four-speed type chosen because it affords four times the resolution of a single-speed resolver. A key innovative aspect of this system is its position-feedback signal- conditioning circuits, which condition the resolver output signal for multiple ranges of rotational speed. In the preferred version of the system, two rotational- speed ranges are included, but any number of ranges could be added to expand the speed range or increase resolution in particular ranges. In the preferred version, the resolver output is conditioned with two resolver-to-digital converters (RDCs). One RDC is used for speeds from 0.00012 to 2.5 rpm; the other RDC is used for speeds of 2.5 to 6,000 rpm. For the lower speed range, the number of discrete steps of RDC output per revolution was set at 262,144 (4 quadrants at 16 bits per quadrant). For the higher speed range, the number of discrete steps per revolution was set at 4,096 (4 quadrants at 10 bits per quadrant).

  18. Detection of cat-eye effect echo based on unit APD

    NASA Astrophysics Data System (ADS)

    Wu, Dong-Sheng; Zhang, Peng; Hu, Wen-Gang; Ying, Jia-Ju; Liu, Jie

    2016-10-01

    The cat-eye effect echo of optical system can be detected based on CCD, but the detection range is limited within several kilometers. In order to achieve long-range even ultra-long-range detection, it ought to select APD as detector because of the high sensitivity of APD. The detection system of cat-eye effect echo based on unit APD is designed in paper. The implementation scheme and key technology of the detection system is presented. The detection performances of the detection system including detection range, detection probability and false alarm probability are modeled. Based on the model, the performances of the detection system are analyzed using typical parameters. The results of numerical calculation show that the echo signal-to-noise ratio is greater than six, the detection probability is greater than 99.9% and the false alarm probability is less tan 0.1% within 20 km detection range. In order to verify the detection effect, we built the experimental platform of detection system according to the design scheme and carry out the field experiments. The experimental results agree well with the results of numerical calculation, which prove that the detection system based on the unit APD is feasible to realize remote detection for cat-eye effect echo.

  19. Research and emulation of ranging in BPON system

    NASA Astrophysics Data System (ADS)

    Yang, Guangxiang; Tao, Dexin; He, Yan

    2005-12-01

    Ranging is one of the key technologies in Broadband Passive Optical Network based on the ATM (BPON) system. It is complex for software designers and difficult to test. In order to simplify the ranging procedure, enhance its efficiency, and find an appropriate method to verify it, a new ranging procedure that completely satisfies the requirements specified in ITU-T G.983.1 and one verifying method is proposed in this paper. A kind of ranging procedure without serial number (SN) searching function, called one-by-one ranging are developed under the condition of cold PON, cold Optical Network Termination (ONU). The ranging procedure includes the use of OLT and ONU flow charts respectively. By using the network emulation software OPNET, the BPON system is modeled and the ranging procedure is simulated. The emulation experimental results show that the presented ranging procedure can effectively eliminate the collision of burst mode signals between ONUs, which can be ranged one-by-one under the controlling of OLT, while also enhancing the ranging efficiency. As all of the message formats used in this research conform with the ITU-T G.983.1, the ranging procedure can meet the protocol specifications with good interoperability, and is very compatible with products of other manufacturer. According to the present study of ranging procedures, guidelines and principles are provided, Also some design difficulties are eliminated in the software design.

  20. Solar cell power for field instrumentation at White Sands Missile range. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bond, J.W. Jr..; Reckart, D.H. Jr; Milway, W.B.

    1978-01-01

    The initial phase of an Instrumentation Development Project to explore and document what solar power can do for remote field instrumentation systems is described. The work scope consisted of selection, design, construction, test, and delivery of a solar cell power system for White Sands Missile Range. A Drone Formation Control System Interrogator was selected; a power supply was built and installed in the San Andres Mountain Range at WSMR in late August 1977.

  1. Programmable near-infrared ranging system

    DOEpatents

    Everett, Jr., Hobart R.

    1989-01-01

    A high angular resolution ranging system particularly suitable for indoor plications involving mobile robot navigation and collision avoidance uses a programmable array of light emitters that can be sequentially incremented by a microprocessor. A plurality of adjustable level threshold detectors are used in an optical receiver for detecting the threshold level of the light echoes produced when light emitted from one or more of the emitters is reflected by a target or object in the scan path of the ranging system.

  2. New progress of ranging technology at Wuhan Satellite Laser Ranging Station

    NASA Technical Reports Server (NTRS)

    Xia, Zhiz-Hong; Ye, Wen-Wei; Cai, Qing-Fu

    1993-01-01

    A satellite laser ranging system with an accuracy of the level of centimeter has been successfully developed at the Institute of Seismology, State Seismological Bureau with the cooperation of the Institute of Geodesy and Geophysics, Chinese Academy of Science. With significant improvements on the base of the second generation SLR system developed in 1985, ranging accuracy of the new system has been upgraded from 15 cm to 3-4 cm. Measuring range has also been expanded, so that the ETALON satellite with an orbit height of 20,000 km launched by the former U.S.S.R. can now be tracked. Compared with the 2nd generation SLR system, the newly developed system has the following improvements. A Q modulated laser is replaced by a mode-locked YAG laser. The new device has a pulse width of 150 ps and a repetition rate of 1-4 pps. A quick response photomultiplier has been adopted as the receiver for echo; for example, the adoption of the MCP tube has obviously reduced the jitter error of the transit time and has improved the ranging accuracy. The whole system is controlled by an IBM PC/XT Computer to guide automatic tracking and measurement. It can carry out these functions for satellite orbit calculation, real-time tracking and adjusting, data acquisition and the preprocessed of observing data, etc. The automatization level and reliability of the observation have obviously improved.

  3. Setting up a mobile Lidar (DIAL) system for detecting chemical warfare agents

    NASA Astrophysics Data System (ADS)

    Kavosh Tehrani, M.; Mohammad, M. Malek; Jaafari, E.; Mobashery, A.

    2015-03-01

    The mobile light detection and ranging DIAL system of Malek Ashtar University of Technology has been developed for the detection of chemical warfare agents whose absorption wavelengths are in the range of 9.2-10.8 μm tunable CO2 lasers of the system. In this paper, this system is first described and then ammonia detection is analyzed experimentally. Also, experimental results of detecting a sarin agent simulant, dimethyl-methyl phosphonate (DMMP), are presented. The power levels received from different ranges to detect specific concentrations of NH3 and DMMP have been measured and debated. The primary test results with a 150 ns clipped pulse width by passive pinhole plasma shutter indicate that the system is capable of monitoring several species of pollutants in the range of about 1 km, with a 20 m spatial and 2 min temporal resolution.

  4. Mission Information and Test Systems Summary of Accomplishments, 2012-2013

    NASA Technical Reports Server (NTRS)

    McMorrow, Sean; Sherrard, Roberta; Gibbs, Yvonne

    2015-01-01

    This annual report covers the activities of the NASA Dryden Flight Research Center's Mission Information and Test Systems directorate, which include the Western Aeronautical Test Range (Range Engineering and Range Operations), the Simulation Engineering Branch, and Information Services. This report contains highlights, current projects, and various awards achieved throughout 2012 and 2013.

  5. Passive range estimation using dual baseline triangulation

    NASA Astrophysics Data System (ADS)

    Pieper, Ronald J.; Cooper, Alfred W.; Pelegris, G.

    1996-03-01

    Modern combat systems based on active radar sensing suffer disadvantages against low-flying targets in cluttered backgrounds. Use of passive infrared sensors with these systems, either in cooperation or as an alternative, shows potential for improving target detection and declaration range for targets crossing the horizon. Realization of this potential requires fusion of target position data from dissimilar sensors, or passive sensor measurement of target range. The availability of passive sensors that can supply both range and bearing data on such targets would significantly extend the robustness of an integrated ship self-defense system. This paper considers a new method of range determination with passive sensors based on the principle of triangulation, extending the principle to two orthogonal baselines. The performance of single or double baseline triangulation depends on sensor bearing precision and direction to target. An expression for maximum triangulation range at a required accuracy is derived as a function of polar angle relative to the center of the dual-baseline system. Limitations in the dual- baseline model due to the geometrically assessed horizon are also considered.

  6. Geometrical calibration of an AOTF hyper-spectral imaging system

    NASA Astrophysics Data System (ADS)

    Špiclin, Žiga; Katrašnik, Jaka; Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2010-02-01

    Optical aberrations present an important problem in optical measurements. Geometrical calibration of an imaging system is therefore of the utmost importance for achieving accurate optical measurements. In hyper-spectral imaging systems, the problem of optical aberrations is even more pronounced because optical aberrations are wavelength dependent. Geometrical calibration must therefore be performed over the entire spectral range of the hyper-spectral imaging system, which is usually far greater than that of the visible light spectrum. This problem is especially adverse in AOTF (Acousto- Optic Tunable Filter) hyper-spectral imaging systems, as the diffraction of light in AOTF filters is dependent on both wavelength and angle of incidence. Geometrical calibration of hyper-spectral imaging system was performed by stable caliber of known dimensions, which was imaged at different wavelengths over the entire spectral range. The acquired images were then automatically registered to the caliber model by both parametric and nonparametric transformation based on B-splines and by minimizing normalized correlation coefficient. The calibration method was tested on an AOTF hyper-spectral imaging system in the near infrared spectral range. The results indicated substantial wavelength dependent optical aberration that is especially pronounced in the spectral range closer to the infrared part of the spectrum. The calibration method was able to accurately characterize the aberrations and produce transformations for efficient sub-pixel geometrical calibration over the entire spectral range, finally yielding better spatial resolution of hyperspectral imaging system.

  7. Real-Time Quantum Dynamics of Long-Range Electronic Excitation Transfer in Plasmonic Nanoantennas.

    PubMed

    Ilawe, Niranjan V; Oviedo, M Belén; Wong, Bryan M

    2017-08-08

    Using large-scale, real-time, quantum dynamics calculations, we present a detailed analysis of electronic excitation transfer (EET) mechanisms in a multiparticle plasmonic nanoantenna system. Specifically, we utilize real-time, time-dependent, density functional tight binding (RT-TDDFTB) to provide a quantum-mechanical description (at an electronic/atomistic level of detail) for characterizing and analyzing these systems, without recourse to classical approximations. We also demonstrate highly long-range electronic couplings in these complex systems and find that the range of these couplings is more than twice the conventional cutoff limit considered by Förster resonance energy transfer (FRET)-based approaches. Furthermore, we attribute these unusually long-ranged electronic couplings to the coherent oscillations of conduction electrons in plasmonic nanoparticles. This long-range nature of plasmonic interactions has important ramifications for EET; in particular, we show that the commonly used "nearest-neighbor" FRET model is inadequate for accurately characterizing EET even in simple plasmonic antenna systems. These findings provide a real-time, quantum-mechanical perspective for understanding EET mechanisms and provide guidance in enhancing plasmonic properties in artificial light-harvesting systems.

  8. Future Interagency Range and Spaceport Technologies (FIRST) Formulation Products: 1. Transformational Spaceport and Range Concept of Operations. 2. F.I.R.S.T. Business Case Analysis

    NASA Technical Reports Server (NTRS)

    2005-01-01

    The Baseline Report captures range and spaceport capabilities at five sites: KSC, CCAFS, VAFB, Wallops, and Kodiak. The Baseline depicts a future state that relies on existing technology, planned upgrades, and straight-line recapitalization at these sites projected through 2030. The report presents an inventory of current spaceport and range capabilities at these five sites. The baseline is the first part of analyzing a business case for a set of capabilities designed to transform U.S. ground and space launch operations toward a single, integrated national "system" of space transportation systems. The second part of the business case compares current capabilities with technologies needed to support the integrated national "system". The final part, a return on investment analysis, identifies the technologies that best lead to the integrated national system and reduce recurring costs..Numerous data sources were used to define and describe the baseline spaceport and range by identifying major systems and elements and describing capabilities, limitations, and capabilities

  9. Robustness Analysis and Optimally Robust Control Design via Sum-of-Squares

    NASA Technical Reports Server (NTRS)

    Dorobantu, Andrei; Crespo, Luis G.; Seiler, Peter J.

    2012-01-01

    A control analysis and design framework is proposed for systems subject to parametric uncertainty. The underlying strategies are based on sum-of-squares (SOS) polynomial analysis and nonlinear optimization to design an optimally robust controller. The approach determines a maximum uncertainty range for which the closed-loop system satisfies a set of stability and performance requirements. These requirements, de ned as inequality constraints on several metrics, are restricted to polynomial functions of the uncertainty. To quantify robustness, SOS analysis is used to prove that the closed-loop system complies with the requirements for a given uncertainty range. The maximum uncertainty range, calculated by assessing a sequence of increasingly larger ranges, serves as a robustness metric for the closed-loop system. To optimize the control design, nonlinear optimization is used to enlarge the maximum uncertainty range by tuning the controller gains. Hence, the resulting controller is optimally robust to parametric uncertainty. This approach balances the robustness margins corresponding to each requirement in order to maximize the aggregate system robustness. The proposed framework is applied to a simple linear short-period aircraft model with uncertain aerodynamic coefficients.

  10. Overview of the NASA Wallops Flight Facility Mobile Range Control System

    NASA Technical Reports Server (NTRS)

    Davis, Rodney A.; Semancik, Susan K.; Smith, Donna C.; Stancil, Robert K.

    1999-01-01

    The NASA GSFC's Wallops Flight Facility (WFF) Mobile Range Control System (MRCS) is based on the functionality of the WFF Range Control Center at Wallops Island, Virginia. The MRCS provides real time instantaneous impact predictions, real time flight performance data, and other critical information needed by mission and range safety personnel in support of range operations at remote launch sites. The MRCS integrates a PC telemetry processing system (TELPro), a PC radar processing system (PCDQS), multiple Silicon Graphics display workstations (IRIS), and communication links within a mobile van for worldwide support of orbital, suborbital, and aircraft missions. This paper describes the MRCS configuration; the TELPro's capability to provide single/dual telemetry tracking and vehicle state data processing; the PCDQS' capability to provide real time positional data and instantaneous impact prediction for up to 8 data sources; and the IRIS' user interface for setup/display options. With portability, PC-based data processing, high resolution graphics, and flexible multiple source support, the MRCS system is proving to be responsive to the ever-changing needs of a variety of increasingly complex missions.

  11. Materials for Concentrator Photovoltaic Systems: Optical Properties and Solar Radiation Durability

    NASA Astrophysics Data System (ADS)

    French, R. H.; Rodríguez-Parada, J. M.; Yang, M. K.; Lemon, M. F.; Romano, E. C.; Boydell, P.

    2010-10-01

    Concentrator photovoltaic (CPV) systems are designed to operate over a wide range of solar concentrations, from low concentrations of ˜1 to 12 Suns to medium concentrations in the range from 12 to 200 Suns, to high concentration CPV systems going up to 2000 Suns. Many transparent optical materials are used for a wide variety of functions ranging from refractive and reflective optics to homogenizers, encapsulants and even thermal management. The classes of materials used also span a wide spectrum from hydrocarbon polymers (HCP) and fluoropolymers (FP) to silicon containing polymers and polyimides (PI). The optical properties of these materials are essential to the optical behavior of the system. At the same time radiation durability of these materials under the extremely wide range of solar concentrations is a critical performance requirement for the required lifetime of a CPV system. As part of our research on materials for CPV we are evaluating the optical properties and solar radiation durability of various polymeric materials to define the optimum material combinations for various CPV systems.

  12. Characterization Methods for Small Estuarine Systems in the Mid-Atlantic Region of the United States

    EPA Science Inventory

    Various statistical methods were applied to spatially discrete data from 14 intensively sampled small estuarine systems in the mid-Atlantic U.S. The number of sites per system ranged from 6 to 37. The surface area of the systems ranged from 1.9 to 193.4 km2. Parameters examined ...

  13. Underwater single beam circumferentially scanning detection system using range-gated receiver and adaptive filter

    NASA Astrophysics Data System (ADS)

    Tan, Yayun; Zhang, He; Zha, Bingting

    2017-09-01

    Underwater target detection and ranging in seawater are of interest in unmanned underwater vehicles. This study presents an underwater detection system that synchronously scans a collimated laser beam and a narrow field of view to circumferentially detect an underwater target. Hybrid methods of range-gated and variable step-size least mean squares (VSS-LMS) adaptive filter are proposed to suppress water backscattering. The range-gated receiver eliminates the backscattering of near-field water. The VSS-LMS filter extracts the target echo in the remaining backscattering and the constant fraction discriminator timing method is used to improve ranging accuracy. The optimal constant fraction is selected by analysing the jitter noise and slope of the target echo. The prototype of the underwater detection system is constructed and tested in coastal seawater, then the effectiveness of backscattering suppression and high-ranging accuracy is verified through experimental results and analysis discussed in this paper.

  14. Soliton microcomb range measurement.

    PubMed

    Suh, Myoung-Gyun; Vahala, Kerry J

    2018-02-23

    Laser-based range measurement systems are important in many application areas, including autonomous vehicles, robotics, manufacturing, formation flying of satellites, and basic science. Coherent laser ranging systems using dual-frequency combs provide an unprecedented combination of long range, high precision, and fast update rate. We report dual-comb distance measurement using chip-based soliton microcombs. A single pump laser was used to generate dual-frequency combs within a single microresonator as counterpropagating solitons. We demonstrated time-of-flight measurement with 200-nanometer precision at an averaging time of 500 milliseconds within a range ambiguity of 16 millimeters. Measurements at distances up to 25 meters with much lower precision were also performed. Our chip-based source is an important step toward miniature dual-comb laser ranging systems that are suitable for photonic integration. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  15. Report from Orroral

    NASA Technical Reports Server (NTRS)

    Luck, J. MCK.; Greene, B. A.

    1986-01-01

    The National Mapping (Natmap) laser ranging system (NLRS) at Orroral, Australia, designed for satellite and lunar ranging is described. The system is well connected to Doppler, VLBI, and astrometric sites located nearby (the 65-m antenna at Tidbinbilla DSCC 42/43, the Mount Stromlo Photographic Zenith Tube, and the old SAO laser cite) and is now producing results from Lageos and the moon. The operational features of the system's telescope are described together with the principal operating characteristics of the satellite and the lunar ranging. Special consideration is given to the system's errors. The Orroral site is being considered as a base site for GPS programs.

  16. Free range and deep litter poultry production systems: effect on performance, carcass yield and meat composition of cockerel chickens.

    PubMed

    Sogunle, Olajide Mark; Olaniyi, Olagoke Ayobami; Egbeyale, Lawrence Tokunbo; Akinola, Olufemi Sunday; Shittu, Taofeek A; Abiola, Samuel Soladoye; Ladokun, Abimbola O; Sobayo, Richard Abayomi

    2013-01-01

    This study was carried out on 150 cockerel chickens each of Harco Black and Novogen strains to determine their performance, carcass yield and meat composition on free range and deep litter production systems. The birds were brooded for 4 weeks and thereafter allotted to the different production systems for a period of 12 weeks. Each production system was allotted 150 chicks (75 chicks per strain) with three replicates of 25 chicks. The birds on deep litter production system were fed ad libitum while each bird on free range was fed 50 % of its daily feed requirement. On the 84 th day, a total of 36 birds were randomly selected for analysis of the carcass yield and meat composition. The data generated were subjected to a two-way analysis of variance in a 2 × 2 factorial experimental arrangement. Novogen strain consumed less feed (P < 0.05) on free range and had the best feed/gain (2.72). A higher (P < 0.05) shear force value (3.74 N) was obtained in the thigh muscle for birds on free range. The tibia proximal length and breadth, and tibia distal length and breadth were significantly (P < 0.05) affected by the production systems and strains. On free range, Harco black had more meat (85.69 g) than bone (18.07 g) in the breast while Novogen had the lowest meat/bone (2.38). Conclusively, Novogen strain should be raised on free range for a better performance in terms of feed/gain, but for higher meat composition, Harco black is a better strain.

  17. Neotectonics and geomorphic evolution of the northwestern arm of the Yellowstone Tectonic Parabola: Controls on intra-cratonic extensional regimes, southwest Montana

    USGS Publications Warehouse

    Ruleman, Chester A.; Larsen, Mort; Stickney, Michael C.

    2014-01-01

    The catastrophic Hebgen Lake earthquake of 18 August 1959 (MW 7.3) led many geoscientists to develop new methods to better understand active tectonics in extensional tectonic regimes that address seismic hazards. The Madison Range fault system and adjacent Hebgen Lake–Red Canyon fault system provide an intermountain active tectonic analog for regional analyses of extensional crustal deformation. The Madison Range fault system comprises fault zones (~100 km in length) that have multiple salients and embayments marked by preexisting structures exposed in the footwall. Quaternary tectonic activity rates differ along the length of the fault system, with less displacement to the north. Within the Hebgen Lake basin, the 1959 earthquake is the latest slip event in the Hebgen Lake–Red Canyon fault system and southern Madison Range fault system. Geomorphic and paleoseismic investigations indicate previous faulting events on both fault systems. Surficial geologic mapping and historic seismicity support a coseismic structural linkage between the Madison Range and Hebgen Lake–Red Canyon fault systems. On this trip, we will look at Quaternary surface ruptures that characterize prehistoric earthquake magnitudes. The one-day field trip begins and ends in Bozeman, and includes an overview of the active tectonics within the Madison Valley and Hebgen Lake basin, southwestern Montana. We will also review geologic evidence, which includes new geologic maps and geomorphic analyses that demonstrate preexisting structural controls on surface rupture patterns along the Madison Range and Hebgen Lake–Red Canyon fault systems.

  18. Low-cost compact MEMS scanning ladar system for robotic applications

    NASA Astrophysics Data System (ADS)

    Moss, Robert; Yuan, Ping; Bai, Xiaogang; Quesada, Emilio; Sudharsanan, Rengarajan; Stann, Barry L.; Dammann, John F.; Giza, Mark M.; Lawler, William B.

    2012-06-01

    Future robots and autonomous vehicles require compact low-cost Laser Detection and Ranging (LADAR) systems for autonomous navigation. Army Research Laboratory (ARL) had recently demonstrated a brass-board short-range eye-safe MEMS scanning LADAR system for robotic applications. Boeing Spectrolab is doing a tech-transfer (CRADA) of this system and has built a compact MEMS scanning LADAR system with additional improvements in receiver sensitivity, laser system, and data processing system. Improved system sensitivity, low-cost, miniaturization, and low power consumption are the main goals for the commercialization of this LADAR system. The receiver sensitivity has been improved by 2x using large-area InGaAs PIN detectors with low-noise amplifiers. The FPGA code has been updated to extend the range to 50 meters and detect up to 3 targets per pixel. Range accuracy has been improved through the implementation of an optical T-Zero input line. A compact commercially available erbium fiber laser operating at 1550 nm wavelength is used as a transmitter, thus reducing the size of the LADAR system considerably from the ARL brassboard system. The computer interface has been consolidated to allow image data and configuration data (configuration settings and system status) to pass through a single Ethernet port. In this presentation we will discuss the system architecture and future improvements to receiver sensitivity using avalanche photodiodes.

  19. Wide field and highly sensitive angiography based on optical coherence tomography with akinetic swept source.

    PubMed

    Xu, Jingjiang; Song, Shaozhen; Wei, Wei; Wang, Ruikang K

    2017-01-01

    Wide-field vascular visualization in bulk tissue that is of uneven surface is challenging due to the relatively short ranging distance and significant sensitivity fall-off for most current optical coherence tomography angiography (OCTA) systems. We report a long ranging and ultra-wide-field OCTA (UW-OCTA) system based on an akinetic swept laser. The narrow instantaneous linewidth of the swept source with its high phase stability, combined with high-speed detection in the system enable us to achieve long ranging (up to 46 mm) and almost negligible system sensitivity fall-off. To illustrate these advantages, we compare the basic system performances between conventional spectral domain OCTA and UW-OCTA systems and their functional imaging of microvascular networks in living tissues. In addition, we show that the UW-OCTA is capable of different depth-ranging of cerebral blood flow within entire brain in mice, and providing unprecedented blood perfusion map of human finger in vivo . We believe that the UW-OCTA system has promises to augment the existing clinical practice and explore new biomedical applications for OCT imaging.

  20. Wide field and highly sensitive angiography based on optical coherence tomography with akinetic swept source

    PubMed Central

    Xu, Jingjiang; Song, Shaozhen; Wei, Wei; Wang, Ruikang K.

    2016-01-01

    Wide-field vascular visualization in bulk tissue that is of uneven surface is challenging due to the relatively short ranging distance and significant sensitivity fall-off for most current optical coherence tomography angiography (OCTA) systems. We report a long ranging and ultra-wide-field OCTA (UW-OCTA) system based on an akinetic swept laser. The narrow instantaneous linewidth of the swept source with its high phase stability, combined with high-speed detection in the system enable us to achieve long ranging (up to 46 mm) and almost negligible system sensitivity fall-off. To illustrate these advantages, we compare the basic system performances between conventional spectral domain OCTA and UW-OCTA systems and their functional imaging of microvascular networks in living tissues. In addition, we show that the UW-OCTA is capable of different depth-ranging of cerebral blood flow within entire brain in mice, and providing unprecedented blood perfusion map of human finger in vivo. We believe that the UW-OCTA system has promises to augment the existing clinical practice and explore new biomedical applications for OCT imaging. PMID:28101428

  1. A new airborne laser rangefinder dynamic target simulator for non-stationary environment

    NASA Astrophysics Data System (ADS)

    Ma, Pengge; Pang, Dongdong; Yi, Yang

    2017-11-01

    For the non-stationary environment simulation in laser range finder product testing, a new dynamic target simulation system is studied. First of all, the three-pulsed laser ranging principle, laser target signal composition and mathematical representation are introduced. Then, the actual nonstationary working environment of laser range finder is analyzed, and points out that the real sunshine background light clutter and target shielding effect in laser echo become the main influencing factors. After that, the dynamic laser target signal simulation method is given. Eventlly, the implementation of automatic test system based on arbitrary waveform generator is described. Practical application shows that the new echo signal automatic test system can simulate the real laser ranging environment of laser range finder, and is suitable for performance test of products.

  2. In vivo size and shape measurement of the human upper airway using endoscopic longrange optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Armstrong, Julian J.; Leigh, Matthew S.; Walton, Ian D.; Zvyagin, Andrei V.; Alexandrov, Sergey A.; Schwer, Stefan; Sampson, David D.; Hillman, David R.; Eastwood, Peter R.

    2003-07-01

    We describe a long-range optical coherence tomography system for size and shape measurement of large hollow organs in the human body. The system employs a frequency-domain optical delay line of a configuration that enables the combination of high-speed operation with long scan range. We compare the achievable maximum delay of several delay line configurations, and identify the configurations with the greatest delay range. We demonstrate the use of one such long-range delay line in a catheter-based optical coherence tomography system and present profiles of the human upper airway and esophagus in vivo with a radial scan range of 26 millimeters. Such quantitative upper airway profiling should prove valuable in investigating the pathophysiology of airway collapse during sleep (obstructive sleep apnea).

  3. Theoretical analysis of HVAC duct hanger systems

    NASA Technical Reports Server (NTRS)

    Miller, R. D.

    1987-01-01

    Several methods are presented which, together, may be used in the analysis of duct hanger systems over a wide range of frequencies. The finite element method (FEM) and component mode synthesis (CMS) method are used for low- to mid-frequency range computations and have been shown to yield reasonably close results. The statistical energy analysis (SEA) method yields predictions which agree with the CMS results for the 800 to 1000 Hz range provided that a sufficient number of modes participate. The CMS approach has been shown to yield valuable insight into the mid-frequency range of the analysis. It has been demonstrated that it is possible to conduct an analysis of a duct/hanger system in a cost-effective way for a wide frequency range, using several methods which overlap for several frequency bands.

  4. Electromagnetic Compatibility Testing of a Dedicated Short-Range Communication (DSRC) System That Conforms to the Japanese Standard.

    DOT National Transportation Integrated Search

    1998-11-01

    Dedicated short-range communication (DSRC) systems, designed to enhance the efficiency of highway travel, have been proposed for operation in the 5850- to 5925-MHz band. The successful operation of these communication systems depends upon their compa...

  5. Laser Ranging in Solar System: Technology Developments and New Science Measurement Capabilities

    NASA Astrophysics Data System (ADS)

    Sun, X.; Smith, D. E.; Zuber, M. T.; Mcgarry, J.; Neumann, G. A.; Mazarico, E.

    2015-12-01

    Laser Ranging has played a major role in geodetic studies of the Earth over the past 40 years. The technique can potentially be used in between planets and spacecrafts within the solar system to advance planetary science. For example, a direct measurement of distances between planets, such as Mars and Venus would make significant improvements in understanding the dynamics of the whole solar system, including the masses of the planets and moons, asteroids and their perturbing interactions, and the gravity field of the Sun. Compared to the conventional radio frequency (RF) tracking systems, laser ranging is potentially more accurate because it is much less sensitive to the transmission media. It is also more efficient because the laser beams are much better focused onto the targets than RF beams. However, existing laser ranging systems are all Earth centric, that is, from ground stations on Earth to orbiting satellites in near Earth orbits or lunar orbit, and to the lunar retro-reflector arrays deployed by the astronauts in the early days of lunar explorations. Several long distance laser ranging experiments have been conducted with the lidar in space, including a two-way laser ranging demonstration between Earth and the Mercury Laser Altimeter (MLA) on the MESSENGER spacecraft over 24 million km, and a one way laser transmission and detection experiment over 80 million km between Earth and the Mars Orbiting Laser Altimeter (MOLA) on the MGS spacecraft in Mars orbit. A one-way laser ranging operation has been carried out continuously from 2009 to 2014 between multiple ground stations to LRO spacecraft in lunar orbit. The Lunar Laser Communication Demonstration (LLCD) on the LADEE mission has demonstrated that a two way laser ranging measurements, including both the Doppler frequency and the phase shift, can be obtained from the subcarrier or the data clocks of a high speed duplex laser communication system. Plans and concepts presently being studied suggest we may be on the cusp of demonstrating interplanetary laser ranging to bring the future of solar system geodesy and geodyamics into reality.

  6. Automating Range Surveillance Through Radio Interferometry and Field Strength Mapping Techniques

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Space vehicle launches are often delayed because of the challenge of verifying that the range is clear, and such delays are likely to become more prevalent as more and more new spaceports are built. Range surveillance is one of the primary focuses of Range Safety for launches and often drives costs and schedules. As NASA's primary launch operation center, Kennedy Space Center is very interested in new technologies that increase the responsiveness of radio frequency (RF) surveillance systems. These systems help Range Safety personnel clear the range by identifying, pinpointing, and resolving any unknown sources of RF emissions prior to each launch.

  7. NASA-JSC antenna near-field measurement system

    NASA Technical Reports Server (NTRS)

    Cooke, W. P.; Friederich, P. G.; Jenkins, B. M.; Jameson, C. R.; Estrada, J. P.

    1988-01-01

    Work was completed on the near-field range control software. The capabilities of the data processing software were expanded with the addition of probe compensation. In addition, the user can process the measured data from the same computer terminal used for range control. The design of the laser metrology system was completed. It provides precise measruement of probe location during near-field measurements as well as position data for control of the translation beam and probe cart. A near-field range measurement system was designed, fabricated, and tested.

  8. N-scaling of timescales in long-range N-body quantum systems

    NASA Astrophysics Data System (ADS)

    Kastner, Michael

    2017-01-01

    Long-range interacting many-body systems exhibit a number of peculiar and intriguing properties. One of those is the scaling of relaxation times with the number N of particles in a system. In this paper I give a survey of results on long-range quantum spin models that illustrate this scaling behaviour, and provide indications for its common occurrence by making use of Lieb-Robinson bounds. I argue that these findings may help in understanding the extraordinarily short equilibration timescales predicted by typicality techniques.

  9. Effects of range-wide variation in climate and isolation on floral traits and reproductive output of Clarkia pulchella.

    PubMed

    Bontrager, Megan; Angert, Amy L

    2016-01-01

    Plant mating systems and geographic range limits are conceptually linked by shared underlying drivers, including landscape-level heterogeneity in climate and in species' abundance. Studies of how geography and climate interact to affect plant traits that influence mating system and population dynamics can lend insight to ecological and evolutionary processes shaping ranges. Here, we examined how spatiotemporal variation in climate affects reproductive output of a mixed-mating annual, Clarkia pulchella. We also tested the effects of population isolation and climate on mating-system-related floral traits across the range. We measured reproductive output and floral traits on herbarium specimens collected across the range of C. pulchella. We extracted climate data associated with specimens and derived a population isolation metric from a species distribution model. We then examined how predictors of reproductive output and floral traits vary among populations of increasing distance from the range center. Finally, we tested whether reproductive output and floral traits vary with increasing distance from the center of the range. Reproductive output decreased as summer precipitation decreased, and low precipitation may contribute to limiting the southern and western range edges of C. pulchella. High spring and summer temperatures are correlated with low herkogamy, but these climatic factors show contrasting spatial patterns in different quadrants of the range. Limiting factors differ among different parts of the range. Due to the partial decoupling of geography and environment, examining relationships between climate, reproductive output, and mating-system-related floral traits reveals spatial patterns that might be missed when focusing solely on geographic position. © 2016 Botanical Society of America.

  10. Anatomically correct visualization of the human upper airway using a high-speed long range optical coherence tomography system with an integrated positioning sensor

    NASA Astrophysics Data System (ADS)

    Jing, Joseph C.; Chou, Lidek; Su, Erica; Wong, Brian J. F.; Chen, Zhongping

    2016-12-01

    The upper airway is a complex tissue structure that is prone to collapse. Current methods for studying airway obstruction are inadequate in safety, cost, or availability, such as CT or MRI, or only provide localized qualitative information such as flexible endoscopy. Long range optical coherence tomography (OCT) has been used to visualize the human airway in vivo, however the limited imaging range has prevented full delineation of the various shapes and sizes of the lumen. We present a new long range OCT system that integrates high speed imaging with a real-time position tracker to allow for the acquisition of an accurate 3D anatomical structure in vivo. The new system can achieve an imaging range of 30 mm at a frame rate of 200 Hz. The system is capable of generating a rapid and complete visualization and quantification of the airway, which can then be used in computational simulations to determine obstruction sites.

  11. Noise analysis of the seismic system employed in the northern and southern California seismic nets

    USGS Publications Warehouse

    Eaton, J.P.

    1984-01-01

    The seismic networks have been designed and operated to support recording on Develocorders (less than 40db dynamic range) and analog magnetic tape (about 50 db dynamic range). The principal analysis of the records has been based on Develocorder films; and background earth noise levels have been adjusted to be about 1 to 2 mm p-p on the film readers. Since the traces are separated by only 10 to 12 mm on the reader screen, they become hopelessly tangled when signal amplitudes on several adjacent traces exceed 10 to 20 mm p-p. Thus, the background noise level is hardly more than 20 db below the level of largest readable signals. The situation is somewhat better on tape playbacks, but the high level of background noise set to accomodate processing from film records effectively limits the range of maximum-signal to background-earth-noise on high gain channels to a little more than 30 db. Introduction of the PDP 11/44 seismic data acquisition system has increased the potential dynamic range of recorded network signals to more than 60 db. To make use of this increased dynamic range we must evaluate the characteristics and performance of the seismic system. In particular, we must determine whether the electronic noise in the system is or can be made sufficiently low so that background earth noise levels can be lowered significantly to take advantage of the increased dynamic range of the digital recording system. To come to grips with the complex problem of system noise, we have carried out a number of measurements and experiments to evaluate critical components of the system as well as to determine the noise characteristics of the system as a whole.

  12. Assessment of the Relationship Between Flexibility and Adaptive Capacity in Flood Management Systems

    NASA Astrophysics Data System (ADS)

    DiFrancesco, K.; Tullos, D. D.

    2013-12-01

    Discussions around adapting water management systems to future changes often state the need to increase system flexibility. Intuitively, a flexible, easily modifiable system seems desirable when faced with a wide range of uncertain, but plausible future conditions. Yet, despite the frequent use of the terms flexibility, very little work has examined what exactly it means to have a flexible water management system, what makes one system more flexible than another, or the extent to which flexibility increases adaptive capacity. This study applies a methodology for assessing the inherent flexibility of the structural and non-structural components of flood management systems using original flexibility metrics in the categories of: slack, intensity, connectivity, adjustability, and coordination. We use these metrics to assess the flexibility of three sub-systems within the Sacramento Valley flood management system in California, USA under current system conditions as well as with proposed management actions in place. We then assess the range of hydrologic conditions under which each sub-system can meet flood risk targets in order to determine whether more flexible systems are also more robust and able to perform over a wider range of hydrologic conditions. In doing so, we identify flexible characteristics of flood management systems that enhance the ability of the system to preform over a wide range of conditions making them better suited to adapt to an uncertain hydrologic future. We find that the flexibility characteristics that increase the range of conditions under which the system can meet performance goals varies depending on whether the region is considered urban, rural, or a small community. In some cases, a decrease in certain flexibility characteristics is associated with an increase in robustness, indicating that more flexibility is not always desirable. Future work will assess the transferability of these results to other regions and systems.

  13. Switchable Shape Memory Alloys (SMA) Thermal Materials Project

    NASA Technical Reports Server (NTRS)

    Falker, John; Zeitlin, Nancy; Williams, Martha; Fesmire, James

    2014-01-01

    Develop 2-way switchable thermal systems for use in systems that function in cold to hot temperature ranges using different alloy designs for SMA system concepts. In this project, KSC will specifically address designs of two proof of concept SMA systems with transition temperatures in the 65-95 C range and investigate cycle fatigue and "memory loss" due to thermal cycling.

  14. Pulsed multiwavelength laser ranging system. Ph.D. Thesis - Maryland Univ.

    NASA Technical Reports Server (NTRS)

    Abshire, J. B.

    1982-01-01

    A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

  15. 77 FR 49601 - Endangered and Threatened Wildlife and Plants; Endangered Status for Six West Texas Aquatic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-16

    ... very system (four restricted range. springs). Phantom Lake springsnail.... San Solomon Spring very rare in a very system (four restricted range. springs). diminutive amphipod......... San Solomon Spring... Solomon Spring system to include four different existing spring outflows: San Solomon Spring, Giffin...

  16. Flow of water and sediments through Southwestern riparian systems

    Treesearch

    Leonard F. DeBano; Peter F. Ffolliott; Kenneth N. Brooks

    1996-01-01

    The paper describes streamflow, sediment movement and vegetation interactions within riparian systems of the southwestern United States. Riparian systems are found in a wide range of vegetation types, ranging from lower elevation desert environments to high elevation conifer forests. The climatic, vegetative and hydrologic processes operating in the southwestern...

  17. 75 FR 52039 - Biweekly Notice Applications and Amendments to Facility Operating Licenses Involving No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-24

    ... modifications which would replace the existing source range and intermediate range excore detector systems with... excore detector systems with equivalent neutron monitoring systems. The new instrumentation will perform... the design earthquake, the double design earthquake, the Hosgri earthquake, and the loss-of-coolant...

  18. 14 CFR 27.675 - Stops.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.675 Stops. (a) Each control system must have stops that positively limit the range of motion of the pilot's controls. (b) Each stop must be located in the system so that the range of travel of its control is not appreciably...

  19. 14 CFR 29.675 - Stops.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.675 Stops. (a) Each control system must have stops that positively limit the range of motionof the pilot's controls. (b) Each stop must be located in the system so that the range of travel of its control is not appreciably...

  20. Application of infrared uncooled cameras in surveillance systems

    NASA Astrophysics Data System (ADS)

    Dulski, R.; Bareła, J.; Trzaskawka, P.; PiÄ tkowski, T.

    2013-10-01

    The recent necessity to protect military bases, convoys and patrols gave serious impact to the development of multisensor security systems for perimeter protection. One of the most important devices used in such systems are IR cameras. The paper discusses technical possibilities and limitations to use uncooled IR camera in a multi-sensor surveillance system for perimeter protection. Effective ranges of detection depend on the class of the sensor used and the observed scene itself. Application of IR camera increases the probability of intruder detection regardless of the time of day or weather conditions. It also simultaneously decreased the false alarm rate produced by the surveillance system. The role of IR cameras in the system was discussed as well as technical possibilities to detect human being. Comparison of commercially available IR cameras, capable to achieve desired ranges was done. The required spatial resolution for detection, recognition and identification was calculated. The simulation of detection ranges was done using a new model for predicting target acquisition performance which uses the Targeting Task Performance (TTP) metric. Like its predecessor, the Johnson criteria, the new model bounds the range performance with image quality. The scope of presented analysis is limited to the estimation of detection, recognition and identification ranges for typical thermal cameras with uncooled microbolometer focal plane arrays. This type of cameras is most widely used in security systems because of competitive price to performance ratio. Detection, recognition and identification range calculations were made, and the appropriate results for the devices with selected technical specifications were compared and discussed.

  1. Systemic levels of local anaesthetic after intra-peritoneal application--a systematic review.

    PubMed

    Kahokehr, A; Sammour, T; Vather, R; Taylor, M; Stapelberg, F; Hill, A G

    2010-07-01

    There is a lack of cohesive reports on the systemic levels of local anaesthetic after intraperitoneal application. A comprehensive systematic review with no language restriction was conducted. Eighteen suitable articles were identified. Data were compiled and presented according to local anaesthetic agent. Intraperitoneal local anaesthetic has been studied in many different procedures, including open and laparoscopic surgery. A total of 415 patients were included for analysis. There were no cases of clinical toxicity. There were 11 (2.7%) cases with a systemic level above or close to a safe threshold (as determined by the report authors) in three trials utilising intraperitoneal local anaesthetic after laparoscopic cholecystectomy. Intraperitoneal lignocaine doses varied from 100 to 1000 mg, mean Cmax ranged from 1.01 to 4.32 microg/ml and mean Tmax ranged from 15 to 40 minutes. Intraperitoneal bupivacaine doses varied from 50 to 150 mg (weight based doses also reported), mean Cmax ranged from 0.29 to 1.14 microg/ml and mean Tmax ranged from 15 to 60 minutes. Intraperitoneal ropivacaine doses varied from 100 to 300 mg, mean Cmax ranged from 0.66 to 3.76 microg/ml and mean Tmax ranged from 15 to 35 minutes. The addition of adrenaline to intraperitoneal local anaesthetic almost halves systemic levels and prolongs Tmax. Intraperitoneal local anaesthetic results in detectable systemic levels in the perioperative setting. Despite a lack of clinical toxicity, careful attention to dose is still required to prevent potential systemic toxic levels. Clinicians should also consider the addition of adrenaline to intraperitoneal local anaesthetic solutions to further add to the systemic safety profile.

  2. Improved Range Estimation Model for Three-Dimensional (3D) Range Gated Reconstruction

    PubMed Central

    Chua, Sing Yee; Guo, Ningqun; Tan, Ching Seong; Wang, Xin

    2017-01-01

    Accuracy is an important measure of system performance and remains a challenge in 3D range gated reconstruction despite the advancement in laser and sensor technology. The weighted average model that is commonly used for range estimation is heavily influenced by the intensity variation due to various factors. Accuracy improvement in term of range estimation is therefore important to fully optimise the system performance. In this paper, a 3D range gated reconstruction model is derived based on the operating principles of range gated imaging and time slicing reconstruction, fundamental of radiant energy, Laser Detection And Ranging (LADAR), and Bidirectional Reflection Distribution Function (BRDF). Accordingly, a new range estimation model is proposed to alleviate the effects induced by distance, target reflection, and range distortion. From the experimental results, the proposed model outperforms the conventional weighted average model to improve the range estimation for better 3D reconstruction. The outcome demonstrated is of interest to various laser ranging applications and can be a reference for future works. PMID:28872589

  3. A technology review of time-of-flight photon counting for advanced remote sensing

    NASA Astrophysics Data System (ADS)

    Lamb, Robert A.

    2010-04-01

    Time correlated single photon counting (TCSPC) has made tremendous progress during the past ten years enabling improved performance in precision time-of-flight (TOF) rangefinding and lidar. In this review the development and performance of several ranging systems is presented that use TCSPC for accurate ranging and range profiling over distances up to 17km. A range resolution of a few millimetres is routinely achieved over distances of several kilometres. These systems include single wavelength devices operating in the visible; multi-wavelength systems covering the visible and near infra-red; the use of electronic gating to reduce in-band solar background and, most recently, operation at high repetition rates without range aliasing- typically 10MHz over several kilometres. These systems operate at very low optical power (<100μW). The technique therefore has potential for eye-safe lidar monitoring of the environment and obvious military, security and surveillance sensing applications. The review will highlight the theoretical principles of photon counting and progress made in developing absolute ranging techniques that enable high repetition rate data acquisition that avoids range aliasing. Technology trends in TCSPC rangefinding are merging with those of quantum cryptography and its future application to revolutionary quantum imaging provides diverse and exciting research into secure covert sensing, ultra-low power active imaging and quantum rangefinding.

  4. Laser Range and Bearing Finder for Autonomous Missions

    NASA Technical Reports Server (NTRS)

    Granade, Stephen R.

    2004-01-01

    NASA has recently re-confirmed their interest in autonomous systems as an enabling technology for future missions. In order for autonomous missions to be possible, highly-capable relative sensor systems are needed to determine an object's distance, direction, and orientation. This is true whether the mission is autonomous in-space assembly, rendezvous and docking, or rover surface navigation. Advanced Optical Systems, Inc. has developed a wide-angle laser range and bearing finder (RBF) for autonomous space missions. The laser RBF has a number of features that make it well-suited for autonomous missions. It has an operating range of 10 m to 5 km, with a 5 deg field of view. Its wide field of view removes the need for scanning systems such as gimbals, eliminating moving parts and making the sensor simpler and space qualification easier. Its range accuracy is 1% or better. It is designed to operate either as a stand-alone sensor or in tandem with a sensor that returns range, bearing, and orientation at close ranges, such as NASA's Advanced Video Guidance Sensor. We have assembled the initial prototype and are currently testing it. We will discuss the laser RBF's design and specifications. Keywords: laser range and bearing finder, autonomous rendezvous and docking, space sensors, on-orbit sensors, advanced video guidance sensor

  5. Review of stand-alone photovoltaic application projects sponsored by US DOE and US AID

    NASA Technical Reports Server (NTRS)

    Bifano, W. J.

    1981-01-01

    Experience with dc photovoltaic systems (without backup power) and ranging in output from 23 to 3,500 peak watts, in a wide range of environmental conditions and with a wide range of insolation, is described. Cooperation of NASA with other government agencies resulted in the installation of an air pollution monitor in New Jersey, a seismic sensor in Hawaii, power for lookout towers in national forests in California, an electric power system for a Papago Indian village in Arizona, and a power system for a grain mill and water pump in Tangaye, Upper Volta. Significant operational results are discussed and system reliability is assessed for the 20 experimental systems installed since 1976. Additional systems to be installed overseas are highlighted, and economic factors are considered.

  6. Exploring Propulsion System Requirements for More and All-Electric Helicopters

    NASA Technical Reports Server (NTRS)

    Snyder, Christopher A.

    2015-01-01

    Helicopters offer unique capabilities that are important for certain missions. More and all-electric propulsion systems for helicopters offer the potential for improved efficiency, reliability, vehicle and mission capabilities as well as reduced harmful emissions. To achieve these propulsion system-based benefits, the relevant requirements must be understood and developed for the various component, sub-component and ancillary systems of the overall propulsion system. Three representative helicopters were used to explore propulsion and overall vehicle and mission requirements. These vehicles varied from light utility (one to three occupants) to highly capable (three crew members plus ten passengers and cargo). Assuming 15 and 30 year technology availability, analytical models for electric system components were developed to understand component and ancillary requirements. Overall propulsion system characteristics were developed and used for vehicle sizing and mission analyses to understand the tradeoffs of component performance and weight, with increase in vehicle size and mission capability. Study results indicate that only the light utility vehicle retained significant payload for an arbitrary 100 nautical mile range assuming 15 year technology. Thirty year technology assumptions for battery energy storage are sufficient to enable some range and payload capabilities, but further improvements in energy density are required to maintain or exceed payload and range capabilities versus present systems. Hydrocarbon-fueled range extenders can be prudently used to recover range and payload deficiencies resulting from battery energy density limitations. Thermal loads for electric systems are low heat quality, but seem manageable. To realize the benefits from more and all-electric systems, technology goals must be achieved, as well as vehicles, missions and systems identified that are best suited to take advantage of their unique characteristics.

  7. Exploring Propulsion System Requirements for More and All-Electric Helicopters

    NASA Technical Reports Server (NTRS)

    Snyder, Christopher A.

    2015-01-01

    Helicopters offer unique capabilities that are important for certain missions. More and all-electric propulsion systems for helicopters offer the potential for improved efficiency, reliability, vehicle and mission capabilities as well as reduced harmful emissions. To achieve these propulsion system-based benefits, the relevant requirements must be understood and developed for the various component, sub-component and ancillary systems of the overall propulsion system. Three representative helicopters were used to explore propulsion and overall vehicle and mission requirements. These vehicles varied from light utility (one to three occupants) to highly capable (three crew members plus ten passengers and cargo). Assuming 15 and 30 year technology availability, analytical models for electric system components were developed to understand component and ancillary requirements. Overall propulsion system characteristics were developed and used for vehicle sizing and mission analyses to understand the tradeoffs of component performance and weight, with increase in vehicle size and mission capability. Study results indicate that only the light utility vehicle retained significant payload for an arbitrary 100 nautical mile range assuming 15 year technology. Thirty year technology assumptions for battery energy storage are sufficient to enable some range and payload capabilities, but further improvements in energy density are required to maintain or exceed payload and range capabilities versus present systems. Hydrocarbon-fueled range extenders can be prudently used to recover range and payload deficiencies resulting from battery energy density limitations. Thermal loads for electric systems are low heat quality, but seem manageable. To realize the benefits from more and all-electric systems, technology goals must be achieved, as well as identify vehicles, missions and systems that are best suited to take advantage of their unique characteristics.

  8. An optical approach to proximity-operations communications for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Marshalek, Robert G.

    1991-01-01

    An optical communications system is described that supports bi-directional interconnections between Space Station Freedom (SSF) and a host of attached and co-orbiting platforms. These proximity-operations (Prox-Ops) platforms are categorized by their maximum distance from SSF, with several remaining inside 1-km range and several extending out to 37-km and 2000-km ranges in the initial and growth phases, respectively. Two distinct Prox-Ops optical terminals are described. A 1-cm-aperture system is used on the short-range platforms to reduce payload mass, and a 10-cm-aperture system is used on the long-range platforms and on SSF to support the optical link budgets. The system supports up to four simultaneous user links, by assigning wavelengths to the various platforms and by using separate SSF terminals for each link.

  9. An approach to instrument qualified visual range

    NASA Astrophysics Data System (ADS)

    Courtade, Benoît; Bonnet, Jordan; Woodruff, Chris; Larson, Josiah; Giles, Andrew; Sonde, Nikhil; Moore, C. J.; Schimon, David; Harris, David Money; Pond, Duane; Way, Scott

    2008-04-01

    This paper describes a system that calculates aircraft visual range with instrumentation alone. A unique message is encoded using modified binary phase shift keying and continuously flashed at high speed by ALSF-II runway approach lights. The message is sampled at 400 frames per second by an aircraft borne high-speed camera. The encoding is designed to avoid visible flicker and minimize frame rate. Instrument qualified visual range is identified as the largest distance at which the aircraft system can acquire and verify the correct, runway-specific signal. Scaled testing indicates that if the system were implemented on one full ALSF-II fixture, instrument qualified range could be established at 5 miles in clear weather conditions.

  10. Experimental evaluation of the performance of pulsed two-color laser-ranging systems

    NASA Technical Reports Server (NTRS)

    Im, Kwaifong E.; Gardner, Chester S.; Abshire, James B.; Mcgarry, Jan F.

    1987-01-01

    Two-color laser-ranging systems can be used to estimate the atmospheric delay by measuring the difference in propagation times between two optical pulses transmitted at different wavelengths. This paper describes horizontal-path ranging experiments that were conducted using flat diffuse targets and cube-corner reflector arrays. Measurements of the timing accuracy of the cross-correlation estimator, atmospheric delay, received pulse shapes, and signal power spectra are presented. The results are in general agreement with theory and indicate that target speckle can be the dominant noise source when the target is small and is located far from the ranging system or when the target consists of a small number of cube-corner reflectors.

  11. Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.

    1995-01-01

    This Interim report consists of a manuscript, 'Receiver Design for Satellite to Satellite Laser Ranging Instrument,' and copies of two papers we co-authored, 'Demonstration of High Sensitivity Laser Ranging System' and 'Semiconductor Laser-Based Ranging Instrument for Earth Gravity Measurements. ' These two papers were presented at the conference Semiconductor Lasers, Advanced Devices and Applications, August 21 -23, 1995, Keystone Colorado. The manuscript is a draft in the preparation for publication, which summarizes the theory we developed on space-borne laser ranging instrument for gravity measurements.

  12. Laser scanning methods and a phase comparison, modulated laser range finder for terrain sensing on a Mars roving vehicle. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Herb, G. T.

    1973-01-01

    Two areas of a laser range finder for a Mars roving vehicle are investigated: (1) laser scanning systems, and (2) range finder methods and implementation. Several ways of rapidly scanning a laser are studied. Two digital deflectors and a matrix of laser diodes, are found to be acceptable. A complete range finder scanning system of high accuracy is proposed. The problem of incident laser spot distortion on the terrain is discussed. The instrumentation for a phase comparison, modulated laser range finder is developed and sections of it are tested.

  13. Transformation Systems at NASA Ames

    NASA Technical Reports Server (NTRS)

    Buntine, Wray; Fischer, Bernd; Havelund, Klaus; Lowry, Michael; Pressburger, TOm; Roach, Steve; Robinson, Peter; VanBaalen, Jeffrey

    1999-01-01

    In this paper, we describe the experiences of the Automated Software Engineering Group at the NASA Ames Research Center in the development and application of three different transformation systems. The systems span the entire technology range, from deductive synthesis, to logic-based transformation, to almost compiler-like source-to-source transformation. These systems also span a range of NASA applications, including solving solar system geometry problems, generating data analysis software, and analyzing multi-threaded Java code.

  14. Note: A wide temperature range MOKE system with annealing capability.

    PubMed

    Chahil, Narpinder Singh; Mankey, G J

    2017-07-01

    A novel sample stage integrated with a longitudinal MOKE system has been developed for wide temperature range measurements and annealing capabilities in the temperature range 65 K < T < 760 K. The sample stage incorporates a removable platen and copper block with inserted cartridge heater and two thermocouple sensors. It is supported and thermally coupled to a cold finger with two sapphire bars. The sapphire based thermal coupling enables the system to perform at higher temperatures without adversely affecting the cryostat and minimizes thermal drift in position. In this system the hysteresis loops of magnetic samples can be measured simultaneously while annealing the sample in a magnetic field.

  15. 110 °C range athermalization of wavefront coding infrared imaging systems

    NASA Astrophysics Data System (ADS)

    Feng, Bin; Shi, Zelin; Chang, Zheng; Liu, Haizheng; Zhao, Yaohong

    2017-09-01

    110 °C range athermalization is significant but difficult for designing infrared imaging systems. Our wavefront coding athermalized infrared imaging system adopts an optical phase mask with less manufacturing errors and a decoding method based on shrinkage function. The qualitative experiments prove that our wavefront coding athermalized infrared imaging system has three prominent merits: (1) working well over a temperature range of 110 °C; (2) extending the focal depth up to 15.2 times; (3) achieving a decoded image being approximate to its corresponding in-focus infrared image, with a mean structural similarity index (MSSIM) value greater than 0.85.

  16. Optimal Detection Range of RFID Tag for RFID-based Positioning System Using the k-NN Algorithm.

    PubMed

    Han, Soohee; Kim, Junghwan; Park, Choung-Hwan; Yoon, Hee-Cheon; Heo, Joon

    2009-01-01

    Positioning technology to track a moving object is an important and essential component of ubiquitous computing environments and applications. An RFID-based positioning system using the k-nearest neighbor (k-NN) algorithm can determine the position of a moving reader from observed reference data. In this study, the optimal detection range of an RFID-based positioning system was determined on the principle that tag spacing can be derived from the detection range. It was assumed that reference tags without signal strength information are regularly distributed in 1-, 2- and 3-dimensional spaces. The optimal detection range was determined, through analytical and numerical approaches, to be 125% of the tag-spacing distance in 1-dimensional space. Through numerical approaches, the range was 134% in 2-dimensional space, 143% in 3-dimensional space.

  17. Microbiological and chemical properties of litter from different chicken types and production systems.

    PubMed

    Omeira, N; Barbour, E K; Nehme, P A; Hamadeh, S K; Zurayk, R; Bashour, I

    2006-08-15

    Chicken litter is produced in large quantities from all types of poultry raising activities. It is primarily used for land application, thus it is essential to analyze its properties before it is released to the environment. The objective of this study is to compare the microbiological and chemical properties of litter generated from layer and broiler chickens reared under intensive and free-range production systems. The microbiological analysis consisted of the enumeration of total bacteria, total coliforms, Staphylococcus species, Salmonella species and Clostridium perfringens. Chicken litter from layers reared under intensive and free range systems showed lower mean total bacterial count than the litter collected from chicken broilers reared under either of the two systems (P=0.0291). The litter from intensive layers had the lowest mean total coliform counts (P=0.0222) while the lowest Staphylococcus species count was observed in the litter from free-range layers (P=0.0077). The C. perfringens count was the lowest in chicken litter from intensively raised broilers and layers (P=0.0001). The chemical properties of litter from the different chicken types and production systems were compared based on determination of pH, electrical conductivity, carbon, nitrogen, phosphorus, potassium, cadmium and zinc. Litter from free-range broilers showed the highest pH value (P=0.0005); however, the electrical conductivity was higher in the litter from both intensive and free-range layers compared to the litter from both broiler production systems (P=0.0117). Chicken litter from intensive systems had higher nitrogen content than litter from free-range systems (P=0.0000). The total phosphorus was the lowest in free-range broiler litter (P=0.0001), while the total potassium was the lowest in litter from intensively managed broilers (P=0.0000). Zinc appeared higher in litter from layers compared to that from broilers (P=0.0101). The cadmium content was higher in the litter from free-range broilers and layers compared to that in the litter from intensively managed systems (P=0.0439). Staphylococcus species in the litter as well as cadmium concentrations seem to be the most critical parameters presenting risks on the environment and on human health. Based on the lowest coliform counts (an indication of water pollution), the high nutrient levels and the low cadmium values, litter from intensively managed layers appears as the most suitable for application on agricultural soils.

  18. Investigations of soft and hard tissues in oral cavity by spectral domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Madjarova, Violeta Dimitrova; Yasuno, Yoshiaki; Makita, Shuichi; Hori, Yasuaki; Voeffray, Jean-Baptiste; Itoh, Masahide; Yatagai, Toyohiko; Tamura, Masami; Nanbu, Toshiyuki

    2006-02-01

    Fourier Domain Optical Coherence Tomography (SD-OCT) systems for dental measurements are demonstrated. Two systems have been developed. The first system is fiber based Michelson interferometer with super luminescent diodes at 1310 nm and 100 nm FWHM as a light source. The sensitivity of the system was 106 dB with depth measurement range in air of 2.5 mm. The second systems is a fiber based Mach-Zehnder interferometer with wavelength scanning laser as light source at center wavelength of 1310 nm, wavelength range of 110 nm and scanning rate of 20 KHz. The sensitivity of the system is 112 dB and depth measurement range in air is 6 mm. Both systems can acquire real-time three dimensional (3-D) images in the range of several second. The systems were applied for early caries detection in tooth, for diagnostics of tooth condition after operational tooth treatment, and for diagnostics of the alveolar bone structure. In-vivo measurements were performed on two volunteers. The systems were able to detect discontinuities in tooth and resin filling after tooth treatment. In addition early carries lesion was detected in one of the volunteers. The 3-D profile of the alveolar bone was acquired for first time with non-contact method.

  19. Local dynamic range compensation for scanning electron microscope imaging system.

    PubMed

    Sim, K S; Huang, Y H

    2015-01-01

    This is the extended project by introducing the modified dynamic range histogram modification (MDRHM) and is presented in this paper. This technique is used to enhance the scanning electron microscope (SEM) imaging system. By comparing with the conventional histogram modification compensators, this technique utilizes histogram profiling by extending the dynamic range of each tile of an image to the limit of 0-255 range while retains its histogram shape. The proposed technique yields better image compensation compared to conventional methods. © Wiley Periodicals, Inc.

  20. Spectrum Management Guidelines for National and Service Test and Training Ranges

    DTIC Science & Technology

    2017-07-12

    GPS Global Positioning System ISM Installation Spectrum Manager JTIDS Joint Tactical Information Distribution System KMR Kwajalein Missile Range... information UAV unmanned aerial vehicle US&P United States and Possessions Spectrum Management Guidelines for National and Service Test and Training...frequency deconfliction processes. The AFC will inform the range or center commander and the Installation Spectrum Manager (ISM) at the

  1. Image dissector camera system study

    NASA Technical Reports Server (NTRS)

    Howell, L.

    1984-01-01

    Various aspects of a rendezvous and docking system using an image dissector detector as compared to a GaAs detector were discussed. Investigation into a gimbled scanning system is also covered and the measured video response curves from the image dissector camera are presented. Rendezvous will occur at ranges greater than 100 meters. The maximum range considered was 1000 meters. During docking, the range, range-rate, angle, and angle-rate to each reflector on the satellite must be measured. Docking range will be from 3 to 100 meters. The system consists of a CW laser diode transmitter and an image dissector receiver. The transmitter beam is amplitude modulated with three sine wave tones for ranging. The beam is coaxially combined with the receiver beam. Mechanical deflection of the transmitter beam, + or - 10 degrees in both X and Y, can be accomplished before or after it is combined with the receiver beam. The receiver will have a field-of-view (FOV) of 20 degrees and an instantaneous field-of-view (IFOV) of two milliradians (mrad) and will be electronically scanned in the image dissector. The increase in performance obtained from the GaAs photocathode is not needed to meet the present performance requirements.

  2. A versatile electrophoresis system for the analysis of high- and low-molecular-weight proteins

    PubMed Central

    Tastet, Christophe; Lescuyer, Pierre; Diemer, Hélène; Luche, Sylvie; van Dorsselaer, Alain; Rabilloud, Thierry

    2003-01-01

    A new, versatile, multiphasic buffer system for high resolution sodium dodecyl sulfatepolyacrylamide gel electrophoresis of proteins in the relative molecular weight Mw range of 300,000-3000 Da is described. The system, based on the theory of multiphasic zone electrophoresis, allows complete stacking and destacking of proteins in the above Mw range. The buffer system uses taurine and chloride as trailing and leading ion, respectively, and Tris, at a pH close to its pKa, as the buffering counter ion. Coupled with limited variation in the acrylamide concentration, this electrophoresis system allows to tailor the resolution in the 6–200 kDa Mw range, with minimal difficulties in the post electrophoretic identification processes. PMID:12783456

  3. Collaborative Point Paper on Border Surveillance Technology

    DTIC Science & Technology

    2007-06-01

    Systems PLC LORHIS (Long Range Hyperspectral Imaging System ) can be configured for either manned or unmanned aircraft to automatically detect and...Airships, and/or Aerostats, (RF, Electro-Optical, Infrared, Video) • Land- based Sensor Systems (Attended/Mobile and Unattended: e.g., CCD, Motion, Acoustic...electronic surveillance technologies for intrusion detection and warning. These ground- based systems are primarily short-range, up to around 500 meters

  4. Determining position, velocity and acceleration of free-ranging animals with a low-cost unmanned aerial system.

    PubMed

    Harvey, Richard J; Roskilly, Kyle; Buse, Chris; Evans, Hannah K; Hubel, Tatjana Y; Wilson, Alan M

    2016-09-01

    Unmanned aerial systems (UASs), frequently referred to as 'drones', have become more common and affordable and are a promising tool for collecting data on free-ranging wild animals. We used a Phantom-2 UAS equipped with a gimbal-mounted camera to estimate position, velocity and acceleration of a subject on the ground moving through a grid of GPS surveyed ground control points (area ∼1200 m(2)). We validated the accuracy of the system against a dual frequency survey grade GPS system attached to the subject. When compared with GPS survey data, the estimations of position, velocity and acceleration had a root mean square error of 0.13 m, 0.11 m s(-1) and 2.31 m s(-2), respectively. The system can be used to collect locomotion and localisation data on multiple free-ranging animals simultaneously. It does not require specialist skills to operate, is easily transported to field locations, and is rapidly and easily deployed. It is therefore a useful addition to the range of methods available for field data collection on free-ranging animal locomotion. © 2016. Published by The Company of Biologists Ltd.

  5. Fractal landscapes in biological systems: long-range correlations in DNA and interbeat heart intervals

    NASA Technical Reports Server (NTRS)

    Stanley, H. E.; Buldyrev, S. V.; Goldberger, A. L.; Hausdorff, J. M.; Havlin, S.; Mietus, J.; Sciortino, F.; Simons, M.

    1992-01-01

    Here we discuss recent advances in applying ideas of fractals and disordered systems to two topics of biological interest, both topics having common the appearance of scale-free phenomena, i.e., correlations that have no characteristic length scale, typically exhibited by physical systems near a critical point and dynamical systems far from equilibrium. (i) DNA nucleotide sequences have traditionally been analyzed using models which incorporate the possibility of short-range nucleotide correlations. We found, instead, a remarkably long-range power law correlation. We found such long-range correlations in intron-containing genes and in non-transcribed regulatory DNA sequences as well as intragenomic DNA, but not in cDNA sequences or intron-less genes. We also found that the myosin heavy chain family gene evolution increases the fractal complexity of the DNA landscapes, consistent with the intron-late hypothesis of gene evolution. (ii) The healthy heartbeat is traditionally thought to be regulated according to the classical principle of homeostasis, whereby physiologic systems operate to reduce variability and achieve an equilibrium-like state. We found, however, that under normal conditions, beat-to-beat fluctuations in heart rate display long-range power law correlations.

  6. 78 FR 41227 - Endangered and Threatened Wildlife and Plants; Determination of Endangered Species Status for Six...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-09

    ... common in a very restricted range. system (four springs). Phantom Lake springsnail....... San Solomon Spring very rare in a very restricted range. system (four springs). diminutive amphipod San Solomon... Solomon Spring System. However, we use this term as a common reference for the four springs, which are...

  7. Alternative Pathways in Family Child Care Quality Rating and Improvement Systems

    ERIC Educational Resources Information Center

    Kelton, Robyn E.; Talan, Teri N.; Bloom, Paula J.

    2013-01-01

    As research continues to underscore the positive impact high-quality early childhood programs have on young children, numerous states have implemented quality rating and improvement systems (QRIS) to measure and improve the services young children receive across a wide range of early learning settings. These state systems range from two to five…

  8. Historical MOBLAS system characterization

    NASA Technical Reports Server (NTRS)

    Husson, Van S.

    1993-01-01

    This paper is written as a direct response to the published NASA Laser Geodynamic Satellite (LAGEOS) orbital solution SL7.1, in order to close the data information loop with an emphasis on the NASA Mobile Laser Ranging System's (MOBLAS) LAGEOS full rate data since November 1, 1983. A preliminary analysis of the supporting information (i.e. satellite laser ranging system eccentricities and system dependent range and time bias corrections) contained in SL7.1 indicated centimeter (cm) level discrepancies. In addition, a preliminary analysis of the computed monthly MOBLAS range biases from SL7.1 appear to show cm level systematic trends, some of which appear to be 'real', particularly in the 1984 to 1987 time period. This paper is intended to be a reference document for known MOBLAS systematic errors (magnitude and direction) and for supporting MOBLAS information (eccentricities, hardware configurations, and potential data problem periods). Therefore, this report is different than your typical system characterization report, but will be more valuable to the user. The MOBLAS error models and supporting information contained in this paper will be easily accessible from the Crustal Dynamics Data Information System (CDDIS).

  9. Model-based restoration using light vein for range-gated imaging systems.

    PubMed

    Wang, Canjin; Sun, Tao; Wang, Tingfeng; Wang, Rui; Guo, Jin; Tian, Yuzhen

    2016-09-10

    The images captured by an airborne range-gated imaging system are degraded by many factors, such as light scattering, noise, defocus of the optical system, atmospheric disturbances, platform vibrations, and so on. The characteristics of low illumination, few details, and high noise make the state-of-the-art restoration method fail. In this paper, we present a restoration method especially for range-gated imaging systems. The degradation process is divided into two parts: the static part and the dynamic part. For the static part, we establish the physical model of the imaging system according to the laser transmission theory, and estimate the static point spread function (PSF). For the dynamic part, a so-called light vein feature extraction method is presented to estimate the fuzzy parameter of the atmospheric disturbance and platform movement, which make contributions to the dynamic PSF. Finally, combined with the static and dynamic PSF, an iterative updating framework is used to restore the image. Compared with the state-of-the-art methods, the proposed method can effectively suppress ringing artifacts and achieve better performance in a range-gated imaging system.

  10. Upgrading NASA/DOSE laser ranging system control computers

    NASA Technical Reports Server (NTRS)

    Ricklefs, Randall L.; Cheek, Jack; Seery, Paul J.; Emenheiser, Kenneth S.; Hanrahan, William P., III; Mcgarry, Jan F.

    1993-01-01

    Laser ranging systems now managed by the NASA Dynamics of the Solid Earth (DOSE) and operated by the Bendix Field Engineering Corporation, the University of Hawaii, and the University of Texas have produced a wealth on interdisciplinary scientific data over the last three decades. Despite upgrades to the most of the ranging station subsystems, the control computers remain a mix of 1970's vintage minicomputers. These encompass a wide range of vendors, operating systems, and languages, making hardware and software support increasingly difficult. Current technology allows replacement of controller computers at a relatively low cost while maintaining excellent processing power and a friendly operating environment. The new controller systems are now being designed using IBM-PC-compatible 80486-based microcomputers, a real-time Unix operating system (LynxOS), and X-windows/Motif IB, and serial interfaces have been chosen. This design supports minimizing short and long term costs by relying on proven standards for both hardware and software components. Currently, the project is in the design and prototyping stage with the first systems targeted for production in mid-1993.

  11. Integrated communications and optical navigation system

    NASA Astrophysics Data System (ADS)

    Mueller, J.; Pajer, G.; Paluszek, M.

    2013-12-01

    The Integrated Communications and Optical Navigation System (ICONS) is a flexible navigation system for spacecraft that does not require global positioning system (GPS) measurements. The navigation solution is computed using an Unscented Kalman Filter (UKF) that can accept any combination of range, range-rate, planet chord width, landmark, and angle measurements using any celestial object. Both absolute and relative orbit determination is supported. The UKF employs a full nonlinear dynamical model of the orbit including gravity models and disturbance models. The ICONS package also includes attitude determination algorithms using the UKF algorithm with the Inertial Measurement Unit (IMU). The IMU is used as the dynamical base for the attitude determination algorithms. This makes the sensor a more capable plug-in replacement for a star tracker, thus reducing the integration and test cost of adding this sensor to a spacecraft. Recent additions include an integrated optical communications system which adds communications, and integrated range and range rate measurement and timing. The paper includes test results from trajectories based on the NASA New Horizons spacecraft.

  12. Heart rate, multiple body temperature, long-range and long-life telemetry system for free-ranging animals

    NASA Technical Reports Server (NTRS)

    Lund, G. F.; Westbrook, R. M.; Fryer, T. B.

    1980-01-01

    The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.

  13. 50 CFR 30.1 - Surplus range animals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Surplus range animals. 30.1 Section 30.1... NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.1 Surplus range animals. Range animals on fenced wildlife refuge areas, including buffalo and longhorn cattle, determined...

  14. 50 CFR 30.1 - Surplus range animals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Surplus range animals. 30.1 Section 30.1... NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.1 Surplus range animals. Range animals on fenced wildlife refuge areas, including buffalo and longhorn cattle, determined...

  15. 50 CFR 30.1 - Surplus range animals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Surplus range animals. 30.1 Section 30.1... NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.1 Surplus range animals. Range animals on fenced wildlife refuge areas, including buffalo and longhorn cattle, determined...

  16. 50 CFR 30.1 - Surplus range animals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Surplus range animals. 30.1 Section 30.1... NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.1 Surplus range animals. Range animals on fenced wildlife refuge areas, including buffalo and longhorn cattle, determined...

  17. 50 CFR 30.1 - Surplus range animals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Surplus range animals. 30.1 Section 30.1... NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.1 Surplus range animals. Range animals on fenced wildlife refuge areas, including buffalo and longhorn cattle, determined...

  18. Digital Tone Ranging Modem.

    DOT National Transportation Integrated Search

    1976-05-01

    This report describes a digital ranging modem implementation based on side-tone ranging concepts. The ranging technique implemented and tested in the DOT/TSC avionics laboratory has direct application to the AEROSAT surveillance system. The performan...

  19. Estimability and simple dynamical analyses of range (range-rate range-difference) observations to artificial satellites. [laser range observations to LAGEOS using non-Bayesian statistics

    NASA Technical Reports Server (NTRS)

    Vangelder, B. H. W.

    1978-01-01

    Non-Bayesian statistics were used in simulation studies centered around laser range observations to LAGEOS. The capabilities of satellite laser ranging especially in connection with relative station positioning are evaluated. The satellite measurement system under investigation may fall short in precise determinations of the earth's orientation (precession and nutation) and earth's rotation as opposed to systems as very long baseline interferometry (VLBI) and lunar laser ranging (LLR). Relative station positioning, determination of (differential) polar motion, positioning of stations with respect to the earth's center of mass and determination of the earth's gravity field should be easily realized by satellite laser ranging (SLR). The last two features should be considered as best (or solely) determinable by SLR in contrast to VLBI and LLR.

  20. Fundamental Constraints on the Coherence of Probing Signals in the Problem of Maximizing the Resolution and Range in the Stroboscopic Range of Asteroids

    NASA Astrophysics Data System (ADS)

    Zakharchenko, V. D.; Kovalenko, I. G.; Pak, O. V.; Ryzhkov, V. Yu.

    2018-05-01

    The problem of coherence violation in stroboscopic ranging with a high resolution in the range due to mutual phase instability of probing and reference radio signals has been considered. It has been shown that the violation of coherence in stroboscopic ranging systems is equivalent to the action of modulating interface and leads to a decrease in the system sensitivity. Requirements have been formulated for the coherence of reference generators in the stroboscopic processing system. The results of statistical modeling have been presented. It was shown that, in the current state of technology with stability of the frequencies of the reference generators, the achieved coherence is sufficient to probe asteroids with super-resolving signals in the range of up to 70 million kilometers. In this case, the dispersion of the signal in cosmic plasma limits the value of the linear resolution of the asteroid details at this range by the value of 2.7 m. Comparison with the current radar resolution of asteroids has been considered, which, at the end of 2015, were 7.5 m in the range of 7 million kilometers.

  1. The application and research of the multi-receiving telescopes technology in laser ranging to space targets

    NASA Astrophysics Data System (ADS)

    Wu, Zhibo; Zhang, Haifeng; Zhang, Zhongping; Deng, Huarong; Li, Pu; Meng, Wendong; Cheng, Zhien; Shen, Lurun; Tang, Zhenhong

    2014-11-01

    Laser ranging technology can directly measure the distance between space targets and ground stations with the highest measurement precision and will play an irreplaceable role in orbit check and calibrating microwave measurement system. The precise orbit determination and accurate catalogue of space targets can also be realized by laser ranging with multi-stations. Among space targets, most of ones are inactive targets and space debris, which should be paid the great attentions for the safety of active spacecrafts. Because of laser diffuse reflection from the surface of targets, laser ranging to space debris has the characteristics of wide coverage and weak strength of laser echoes, even though the powerful laser system is applied. In order to increase the receiving ability of laser echoes, the large aperture telescope should be adopted. As well known, some disadvantages for one set of large aperture telescope, technical development difficulty and system running and maintenance complexity, will limit its flexible applications. The multi-receiving telescopes technology in laser ranging to space targets is put forward to realize the equivalent receiving ability produced by one larger aperture telescope by way of using multi-receiving telescopes, with the advantages of flexibility and maintenance. The theoretical analysis of the feasibility and key technologies of multi-receiving telescopes technology in laser ranging to space targets are presented in this paper. The experimental measurement system based on the 60cm SLR system and 1.56m astronomical telescopes with a distance of about 50m is established to provide the platform for researching on the multi-receiving telescopes technology. The laser ranging experiments to satellites equipped with retro-reflectors are successfully performed by using the above experimental system and verify the technical feasibility to increase the ability of echo detection. And the multi-receiving telescopes technology will become a novel effective way to improve the detection ability of laser ranging to space debris.

  2. Data acquisition and analysis of range-finding systems for spacing construction

    NASA Technical Reports Server (NTRS)

    Shen, C. N.

    1981-01-01

    For space missions of future, completely autonomous robotic machines will be required to free astronauts from routine chores of equipment maintenance, servicing of faulty systems, etc. and to extend human capabilities in hazardous environments full of cosmic and other harmful radiations. In places of high radiation and uncontrollable ambient illuminations, T.V. camera based vision systems cannot work effectively. However, a vision system utilizing directly measured range information with a time of flight laser rangefinder, can successfully operate under these environments. Such a system will be independent of proper illumination conditions and the interfering effects of intense radiation of all kinds will be eliminated by the tuned input of the laser instrument. Processing the range data according to certain decision, stochastic estimation and heuristic schemes, the laser based vision system will recognize known objects and thus provide sufficient information to the robot's control system which can develop strategies for various objectives.

  3. Adipose Stromal Vascular Fraction Isolation: A Head-to-Head Comparison of 4 Cell Separation Systems #2.

    PubMed

    Aronowitz, Joel A; Lockhart, Ryan A; Hakakian, Cloe S; Birnbaum, Zoe E

    2016-09-01

    With stromal vascular fraction (SVF) cell and adipose-derived stem cell-based technologies translating into the clinical setting, numerous isolation systems have been developed for the point of care isolation of SVF cells from adipose tissue. A relative lack of performance data on these systems can make objective assessment difficult for prospective clinicians. This study compared the performance of 4 SVF cell isolation systems. Four isolation systems were compared: the MultiStation by PNC International, the LipoKit by MediKhan, the GID SVF-2 platform by GID Europe Ltd, and the StemSource 900/MB system by Cytori Therapeutics, Inc. Identical lipoaspirate samples for 5 separate donors were used. Stromal vascular fraction output was compared in terms of nucleated cell yield, viability, residual collagenase activity, sterility of the output, colony-forming unit-fibroblast frequency, frequency of CD31-/CD34+/CD45- cells, and operating statistics. Mean process time ranged from 65.4 to 120.8 minutes. Mean nucleated cell yield per milliliter of tissue processed ranged from 1.01 × 10 cells/mL to 6.24 × 10 cells/mL. Mean cellular viability ranged from 50.3% to 84.02%. Residual collagenase activity was negligible across all systems. Observed colony-forming unit-fibroblast frequency ranged from 0.495% to 1.704%. No significant difference was observed in frequency of CD31-/CD34+/CD45- cells. Results of the anaerobic/aerobic cultures were mixed. There was considerable variability between the outputs of each system. The system used by a clinician should be tailored to the individual needs of the practice. There is a range of cost options available. This study may help clinicians make more educated decisions when choosing an isolation system to meet their clinical needs.

  4. Tonopah Test Range - Index

    Science.gov Websites

    Capabilities Test Operations Center Test Director Range Control Track Control Communications Tracking Radars Us Range Videos/Photos Range Capabilities Test Operations Center Test Director Range Control Track Control Communications Tracking Radars Optical Systems Cinetheodolites Telescopes R&D Telescopes

  5. Multi-range force sensors utilizing shape memory alloys

    DOEpatents

    Varma, Venugopal K.

    2003-04-15

    The present invention provides a multi-range force sensor comprising a load cell made of a shape memory alloy, a strain sensing system, a temperature modulating system, and a temperature monitoring system. The ability of the force sensor to measure contact forces in multiple ranges is effected by the change in temperature of the shape memory alloy. The heating and cooling system functions to place the shape memory alloy of the load cell in either a low temperature, low strength phase for measuring small contact forces, or a high temperature, high strength phase for measuring large contact forces. Once the load cell is in the desired phase, the strain sensing system is utilized to obtain the applied contact force. The temperature monitoring system is utilized to ensure that the shape memory alloy is in one phase or the other.

  6. Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System.

    PubMed

    Song, Young Seop; Yang, Kyung Yong; Youn, Kibum; Yoon, Chiyul; Yeom, Jiwoon; Hwang, Hyeoncheol; Lee, Jehee; Kim, Keewon

    2016-08-01

    To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland-Altman plot with 95% limits of agreement (LoA). MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in -40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in -40° to 40° range were fair for all motions. Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.

  7. Diurnal variation of oxygen and carbonate system parameters in Tampa Bay and Florida Bay

    USGS Publications Warehouse

    Yates, K.K.; Dufore, C.; Smiley, N.; Jackson, C.; Halley, R.B.

    2007-01-01

    Oxygen and carbonate system parameters were measured, in situ, over diurnal cycles in Tampa Bay and Florida Bay, Florida. All system parameters showed distinct diurnal trends in Tampa Bay with an average range of diurnal variation of 39.1 μmol kg− 1 for total alkalinity, 165.1 μmol kg− 1 for total CO2, 0.22 for pH, 0.093 mmol L− 1 for dissolved oxygen, and 218.1 μatm for pCO2. Average range of diurnal variation for system parameters in Tampa Bay was 73% to 93% of the seasonal range of variability for dissolved oxygen and pH. All system parameters measured in Florida Bay showed distinct variation over diurnal time-scales. However, clear diurnal trends were less evident. The average range of diurnal variability in Florida Bay was 62.8 μmol kg− 1 for total alkalinity, 130.4 μmol kg− 1 for total CO2, 0.13 for pH, 0.053 mmol L− 1 for dissolved oxygen, and 139.8 μatm for pCO2. The average range of diurnal variation was 14% to 102% of the seasonal ranges for these parameters. Diurnal variability in system parameters was most influenced by primary productivity and respiration of benthic communities in Tampa Bay, and by precipitation and dissolution of calcium carbonate in Florida Bay. Our data indicate that use of seasonal data sets without careful consideration of diurnal variability may impart significant error in calculations of annual carbon and oxygen budgets. These observations reinforce the need for higher temporal resolution measurements of oxygen and carbon system parameters in coastal ecosystems.

  8. Self-Calibrating Respiratory-Flowmeter Combination

    NASA Technical Reports Server (NTRS)

    Westenskow, Dwayne R.; Orr, Joseph A.

    1990-01-01

    Dual flowmeters ensure accuracy over full range of human respiratory flow rates. System for measurement of respiratory flow employs two flowmeters; one compensates for deficiencies of other. Combination yields easily calibrated system accurate over wide range of gas flow.

  9. Plenoptic Imager for Automated Surface Navigation

    NASA Technical Reports Server (NTRS)

    Zollar, Byron; Milder, Andrew; Milder, Andrew; Mayo, Michael

    2010-01-01

    An electro-optical imaging device is capable of autonomously determining the range to objects in a scene without the use of active emitters or multiple apertures. The novel, automated, low-power imaging system is based on a plenoptic camera design that was constructed as a breadboard system. Nanohmics proved feasibility of the concept by designing an optical system for a prototype plenoptic camera, developing simulated plenoptic images and range-calculation algorithms, constructing a breadboard prototype plenoptic camera, and processing images (including range calculations) from the prototype system. The breadboard demonstration included an optical subsystem comprised of a main aperture lens, a mechanical structure that holds an array of micro lenses at the focal distance from the main lens, and a structure that mates a CMOS imaging sensor the correct distance from the micro lenses. The demonstrator also featured embedded electronics for camera readout, and a post-processor executing image-processing algorithms to provide ranging information.

  10. Long-range eye tracking: A feasibility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jayaweera, S.K.; Lu, Shin-yee

    1994-08-24

    The design considerations for a long-range Purkinje effects based video tracking system using current technology is presented. Past work, current experiments, and future directions are thoroughly discussed, with an emphasis on digital signal processing techniques and obstacles. It has been determined that while a robust, efficient, long-range, and non-invasive eye tracking system will be difficult to develop, such as a project is indeed feasible.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rebolini, Elisa, E-mail: rebolini@lct.jussieu.fr; Toulouse, Julien, E-mail: julien.toulouse@upmc.fr; Savin, Andreas, E-mail: savin@lct.jussieu.fr

    We present a study of the variation of total energies and excitation energies along a range-separated adiabatic connection. This connection links the non-interacting Kohn–Sham electronic system to the physical interacting system by progressively switching on the electron–electron interactions whilst simultaneously adjusting a one-electron effective potential so as to keep the ground-state density constant. The interactions are introduced in a range-dependent manner, first introducing predominantly long-range, and then all-range, interactions as the physical system is approached, as opposed to the conventional adiabatic connection where the interactions are introduced by globally scaling the standard Coulomb interaction. Reference data are reported for themore » He and Be atoms and the H{sub 2} molecule, obtained by calculating the short-range effective potential at the full configuration-interaction level using Lieb's Legendre-transform approach. As the strength of the electron–electron interactions increases, the excitation energies, calculated for the partially interacting systems along the adiabatic connection, offer increasingly accurate approximations to the exact excitation energies. Importantly, the excitation energies calculated at an intermediate point of the adiabatic connection are much better approximations to the exact excitation energies than are the corresponding Kohn–Sham excitation energies. This is particularly evident in situations involving strong static correlation effects and states with multiple excitation character, such as the dissociating H{sub 2} molecule. These results highlight the utility of long-range interacting reference systems as a starting point for the calculation of excitation energies and are of interest for developing and analyzing practical approximate range-separated density-functional methodologies.« less

  12. Electric propulsion options for 10 kW class earth space missions

    NASA Technical Reports Server (NTRS)

    Patterson, M. J.; Curran, Francis M.

    1989-01-01

    Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment have been evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA II 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10(7) to 2.1x10(7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA II 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10(6) to 3.6x10(6) N-s, and approximately 662 to 1072 m/s, respectively.

  13. Design considerations for eye-safe single-aperture laser radars

    NASA Astrophysics Data System (ADS)

    Starodubov, D.; McCormick, K.; Volfson, L.

    2015-05-01

    The design considerations for low cost, shock resistant, compact and efficient laser radars and ranging systems are discussed. The reviewed approach with single optical aperture allows reducing the size, weight and power of the system. Additional design benefits include improved stability, reliability and rigidity of the overall system. The proposed modular architecture provides simplified way of varying the performance parameters of the range finder product family by selecting the sets of specific illumination and detection modules. The performance operation challenges are presented. The implementation of non-reciprocal optical elements is considered. The cross talk between illumination and detection channels for single aperture design is reviewed. 3D imaging capability for the ranging applications is considered. The simplified assembly and testing process for single aperture range finders that allows to mass produce the design are discussed. The eye safety of the range finder operation is summarized.

  14. Approach range and velocity determination using laser sensors and retroreflector targets

    NASA Technical Reports Server (NTRS)

    Donovan, William J.

    1991-01-01

    A laser docking sensor study is currently in the third year of development. The design concept is considered to be validated. The concept is based on using standard radar techniques to provide range, velocity, and bearing information. Multiple targets are utilized to provide relative attitude data. The design requirements were to utilize existing space-qualifiable technology and require low system power, weight, and size yet, operate from 0.3 to 150 meters with a range accuracy greater than 3 millimeters and a range rate accuracy greater than 3 mm per second. The field of regard for the system is +/- 20 deg. The transmitter and receiver design features a diode laser, microlens beam steering, and power control as a function of range. The target design consists of five target sets, each having seven 3-inch retroreflectors, arranged around the docking port. The target map is stored in the sensor memory. Phase detection is used for ranging, with the frequency range-optimized. Coarse bearing measurement is provided by the scanning system (one set of binary optics) angle. Fine bearing measurement is provided by a quad detector. A MIL-STD-1750 A/B computer is used for processing. Initial test results indicate a probability of detection greater than 99 percent and a probability of false alarm less than 0.0001. The functional system is currently at the MIT/Lincoln Lab for demonstration.

  15. The origin of and conditions for clustering in fluids with competing interactions

    NASA Astrophysics Data System (ADS)

    Jadrich, Ryan; Bollinger, Jonathan; Truskett, Thomas

    2015-03-01

    Fluids with competing short-range attractions and long-range repulsions exhibit a rich phase behavior characterized by intermediate range order (IRO), as quantified via the static structure factor. This phase behavior includes cluster formation depending upon density-controlled packing effects and the magnitude and range of the attractive and repulsive interactions. Such model systems mimic (to zeroth order) screened, charge-stabilized, aqueous colloidal dispersions of, e.g., proteins. We employ molecular dynamics simulations and integral equation theory to elucidate a more fundamental microscopic explanation for IRO-driven clustering. A simple criterion is identified that indicates when dynamic, amorphous clustering emerges in a polydisperse system, namely when the Ornstein-Zernike thermal correlation length in the system exceeds the repulsive potential tail range. Remarkably, this criterion also appears tightly correlated to crystalline cluster formation in a monodisperse system. Our new gauge is compared to another phenomenological condition for clustering which is when the IRO peak magnitude exceeds ~ 2.7. Ramifications of crystalline versus amorphous clustering are discussed and potential ways of using our new measure in experiment are put forward.

  16. Effect of a free-range raising system on growth performance, carcass yield, and meat quality of slow-growing chicken.

    PubMed

    Wang, K H; Shi, S R; Dou, T C; Sun, H J

    2009-10-01

    Experiments were conducted to evaluate the effect of free-range raising systems on growth performance, carcass yield, and meat quality of slow-growing chickens. Slow-growing female chickens, Gushi chickens, were selected as the experimental birds. Two hundred 1-d-old female chicks were raised in a pen for 35 d. On d 36, ninety healthy birds, with similar BW (353.7+/-32.1g), were selected and randomly assigned to 2 treatments (indoor treatment and free-range treatment, P>0.05). Each treatment was represented by 3 groups containing 15 birds (45 birds per treatment). During the indoor treatment, the chickens were raised in floor pens in a conventional poultry research house (7 birds/m2). In the free-range treatment, the chickens were housed in a similar indoor house (7 birds/m2); in addition, they also had a free-range grass paddock (1 bird/m2). All birds were provided with the same starter and finisher diets and were raised for 112 d. Results showed that the BW and weight gain of the chickens in the free-range treatment were much lower than that of the chickens in the indoor floor treatments (P<0.05). There was no effect of the free-range raising system on eviscerated carcass, breast, thigh, and wing yield (P>0.05). However, the abdominal fat yield and tibia strength (P<0.05) significantly declined. The nutrient composition (water, protein, and fat), water-holding capacity, shear force, and pH of the muscle were largely unaffected (P>0.05) by the free-range raising system. The data indicated that the free-range raising system could significantly reduce growth performance, abdominal fat, and tibia strength, but with no effect on carcass traits and meat quality in slow-growing chickens.

  17. Test technology on divergence angle of laser range finder based on CCD imaging fusion

    NASA Astrophysics Data System (ADS)

    Shi, Sheng-bing; Chen, Zhen-xing; Lv, Yao

    2016-09-01

    Laser range finder has been equipped with all kinds of weapons, such as tank, ship, plane and so on, is important component of fire control system. Divergence angle is important performance and incarnation of horizontal resolving power for laser range finder, is necessary appraised test item in appraisal test. In this paper, based on high accuracy test on divergence angle of laser range finder, divergence angle test system is designed based on CCD imaging, divergence angle of laser range finder is acquired through fusion technology for different attenuation imaging, problem that CCD characteristic influences divergence angle test is solved.

  18. Autonomous system for launch vehicle range safety

    NASA Astrophysics Data System (ADS)

    Ferrell, Bob; Haley, Sam

    2001-02-01

    The Autonomous Flight Safety System (AFSS) is a launch vehicle subsystem whose ultimate goal is an autonomous capability to assure range safety (people and valuable resources), flight personnel safety, flight assets safety (recovery of valuable vehicles and cargo), and global coverage with a dramatic simplification of range infrastructure. The AFSS is capable of determining current vehicle position and predicting the impact point with respect to flight restriction zones. Additionally, it is able to discern whether or not the launch vehicle is an immediate threat to public safety, and initiate the appropriate range safety response. These features provide for a dramatic cost reduction in range operations and improved reliability of mission success. .

  19. Receiver Design, Performance Analysis, and Evaluation for Space-Borne Laser Altimeters and Space-to-Space Laser Ranging Systems

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.

    1996-01-01

    This progress report consists of two separate reports. The first one describes our work on the use of variable gain amplifiers to increase the receiver dynamic range of space borne laser altimeters such as NASA's Geoscience Laser Altimeter Systems (GLAS). The requirement of the receiver dynamic range was first calculated. A breadboard variable gain amplifier circuit was made and the performance was fully characterized. The circuit will also be tested in flight on board the Shuttle Laser Altimeter (SLA-02) next year. The second report describes our research on the master clock oscillator frequency calibration for space borne laser altimeter systems using global positioning system (GPS) receivers.

  20. Modeling Control Strategies and Range Impacts for Electric Vehicle Integrated Thermal Management Systems with MATLAB/Simulink

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Titov, Gene; Lustbader, Jason Aaron

    The National Renewable Energy Laboratory's (NREL's) CoolSim MATLAB/Simulink modeling framework was used to explore control strategies for an electric vehicle combined loop system. Three system variants of increased complexity and efficiency were explored: a glycol-based positive temperature coefficient heater (PTC), PTC with power electronics and electric motor (PEEM) waste heat recovery, and PTC with PEEM waste heat recovery plus heat pump versions. Additionally, the benefit of electric motor preheating was considered. A two-level control strategy was developed where the mode selection and component control were treated separately. Only the parameters typically available by vehicle sensors were used to control themore » system. The control approach included a mode selection algorithm and controllers for the compressor speed, cabin blower flow rate, coolant flow rate, and the front-end heat exchanger coolant bypass rate. The electric motor was bypassed by the cooling circuit until its temperature exceeded the coolant inlet temperature. The impact of these thermal systems on electric vehicle range during warmup was simulated for the Urban Dynamometer Driving Schedule (UDDS) and Highway Fuel Economy Test (HWFET2X) drive cycles weighted 45%/55% respectively. A range of ambient temperatures from -20 degrees C to +20 degrees C was considered. NREL's Future Automotive Systems Technology Simulator (FASTSim) vehicle modeling tool showed up to a 10.9% improvement in range for the full system over the baseline during warmup from cold soak. The full system with preheat showed up to 17% improvement in range.« less

  1. Beacon Collision Avoidance System (BCAS) Alternative Concepts for Determining Target Positions

    DOT National Transportation Integrated Search

    1978-09-01

    The (Litchford) Beacon-based Collision Avoidance System concept requires the computation of target range and bearing relative to the BCAS aircraft. Techniques for determining target range and bearing under four different assumptions about the ground ...

  2. Comparison of the design criteria of 141 onsite wastewater treatment systems available on the French market.

    PubMed

    Dubois, V; Boutin, C

    2018-06-15

    New EC standards published in 2009 led to a surge in onsite wastewater treatment systems reaching the European market. Here we summarize their technical aspects and compare them to known values used in centralized wastewater treatment. The paper deals with two types of processes: attached-growth systems (AGS) on fine media and suspended-growth systems (SGS). Covering 141 technical approvals and 36 manufacturers, we compare onsite design criteria against the centralized wastewater design criteria for each process. The systems use a wide range of materials for bacterial growth, from soil, sand or gravel to zeolite, coconut shavings or rockwool cubes, with a huge range of variation in useful surface, from 0.26 m 2 /PE for one rockwool cube filter to 5 m 2 /PE for a (traditional system) vertical sand filter. Some rockwool can handle applied daily surface load of 160 g BOD 5 /m 2 . SGS design parameters range from 0.025 to 0.34 kg BOD 5 per kg MLVSS/d with hydraulic retention times of 0.28-3.7 d. For clarifier design, water velocity ranges from 0.15 to 1.47 m/h. In the sludge line, sludge storage volume ranges from 0.125 down to just 0.56 m 3 /PE. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Automated tracking for advanced satellite laser ranging systems

    NASA Astrophysics Data System (ADS)

    McGarry, Jan F.; Degnan, John J.; Titterton, Paul J., Sr.; Sweeney, Harold E.; Conklin, Brion P.; Dunn, Peter J.

    1996-06-01

    NASA's Satellite Laser Ranging Network was originally developed during the 1970's to track satellites carrying corner cube reflectors. Today eight NASA systems, achieving millimeter ranging precision, are part of a global network of more than 40 stations that track 17 international satellites. To meet the tracking demands of a steadily growing satellite constellation within existing resources, NASA is embarking on a major automation program. While manpower on the current systems will be reduced to a single operator, the fully automated SLR2000 system is being designed to operate for months without human intervention. Because SLR2000 must be eyesafe and operate in daylight, tracking is often performed in a low probability of detection and high noise environment. The goal is to automatically select the satellite, setup the tracking and ranging hardware, verify acquisition, and close the tracking loop to optimize data yield. TO accomplish the autotracking tasks, we are investigating (1) improved satellite force models, (2) more frequent updates of orbital ephemerides, (3) lunar laser ranging data processing techniques to distinguish satellite returns from noise, and (4) angular detection and search techniques to acquire the satellite. A Monte Carlo simulator has been developed to allow optimization of the autotracking algorithms by modeling the relevant system errors and then checking performance against system truth. A combination of simulator and preliminary field results will be presented.

  4. Design of a high-numerical-aperture digital micromirror device camera with high dynamic range.

    PubMed

    Qiao, Yang; Xu, Xiping; Liu, Tao; Pan, Yue

    2015-01-01

    A high-NA imaging system with high dynamic range is presented based on a digital micromirror device (DMD). The DMD camera consists of an objective imaging system and a relay imaging system, connected by a DMD chip. With the introduction of a total internal reflection prism system, the objective imaging system is designed with a working F/# of 1.97, breaking through the F/2.45 limitation of conventional DMD projection lenses. As for the relay imaging system, an off-axis design that could correct off-axis aberrations of the tilt relay imaging system is developed. This structure has the advantage of increasing the NA of the imaging system while maintaining a compact size. Investigation revealed that the dynamic range of a DMD camera could be greatly increased, by 2.41 times. We built one prototype DMD camera with a working F/# of 1.23, and the field experiments proved the validity and reliability our work.

  5. Three-Dimensional Planetary Surface Tracking Based on a Simple Ultra-Wideband Impulse-Radio Infrastructure

    NASA Technical Reports Server (NTRS)

    Barton, Richard J.; Ni, David; Ngo, Phong

    2010-01-01

    Several prototype ultra-wideband (UWB) impulse-radio (IR) tracking systems are currently under development at NASA Johnson Space Center (JSC). These systems are being studied for use in tracking of Lunar/Mars rovers and astronauts during early exploration missions when satellite navigation systems (such as GPS) are not available. To date, the systems that have been designed and tested are intended only for two-dimensional location and tracking, but these designs can all be extended to three-dimensional tracking with only minor modifications and increases in complexity. In this presentation, we will briefly review the design and performance of two of the current 2-D systems: one designed specifically for short-range, extremely high-precision tracking (approximately 1-2 cm resolution) and the other designed specifically for much longer range tracking with less stringent precision requirements (1-2 m resolution). We will then discuss a new multi-purpose system design based on a simple UWB-IR architecture that can be deployed easily on a planetary surface to support arbitrary three-dimensional localization and tracking applications. We will discuss utilization of this system as an infrastructure to provide both short-range and long-range tracking and analyze the localization performance of the system in several different configurations. We will give theoretical performance bounds for some canonical system configurations and compare these performance bounds with both numerical simulations of the system as well as actual experimental system performance evaluations.

  6. Wafer-scale pixelated detector system

    DOEpatents

    Fahim, Farah; Deptuch, Grzegorz; Zimmerman, Tom

    2017-10-17

    A large area, gapless, detection system comprises at least one sensor; an interposer operably connected to the at least one sensor; and at least one application specific integrated circuit operably connected to the sensor via the interposer wherein the detection system provides high dynamic range while maintaining small pixel area and low power dissipation. Thereby the invention provides methods and systems for a wafer-scale gapless and seamless detector systems with small pixels, which have both high dynamic range and low power dissipation.

  7. Development of a Maintenance Advisor Expert System for the MK 92 MOD 2 Fire Control System: FC-1 Designation - Time, Range, Bearing FC-1 Acquisition, FC-1 Track - Range, Bearing, and FC-2 Designation - Time, Range, Bearing, FC-2 Acquisition, FC-2 Track - Range, Bearing, and FC-4 and FC-5

    DTIC Science & Technology

    1993-09-01

    is not present at output of the power amplifier- THEN replace train drive motor ELSE continue troubleshooting procedures. 30 Rules offer several...Type Body Type Tires Tires Engine Type Engine Type Battery Type Battery Type Figure 5-2 KOWLEDGE ACCESS BY FRAME AND SLOT 33 B. SEMANTIC NETWORKS A

  8. NGSLR Safety Handbook

    NASA Technical Reports Server (NTRS)

    McGarry, Jan

    2015-01-01

    NASA's Next Generation Satellite Laser Ranging (NGSLR) station is the prototype for NASA's Satellite Laser Ranging (SLR) systems which will be deployed around the world in the coming decade. The NGSLR system will be an autonomous, photon-counting SLR station with an expected absolute range accuracy of better than one centimeter and a normal point (time-averaged) range precision better than one millimeter. The system provides continuous (weather permitting), 24 hour tracking coverage to an existing constellation of approximately two dozen artificial satellites equipped with passive retroreflector arrays, using pulsed, 532 nm, class IV laser systems. Current details on the approved laser systems can be found in the Appendix 1 of this document. This safety plan addresses the potential hazards to emitted laser radiation, which can occur both inside and outside the shelter. Hazards within the shelter are mitigated through posted warning signs, activated warning lights, procedural controls, personal protective equipment (PPE), laser curtains, beam blocking systems, interlock controls, pre-configured laser control settings, and other controls discussed in this document. Since the NGSLR is a satellite tracking system, laser hazards exist outside the shelter to personnel on the shelter roof and to passing aircraft. Potential exposure to personnel outside the system is mitigated through the use of posted warning signs, access control, procedural controls, a stairwell interlock, beam attenuation/blocking devices, and a radar based aircraft detection system.

  9. Review of studies of polymorphic blood systems in the Aymara indigenous population from Bolivia, Peru, and Chile.

    PubMed

    Dittmar, M

    1995-12-01

    A review was made of all studies available from the literature referring to polymorphic blood systems of South American Aymara Indians. 33 original papers published up to 1990 covering a period of 45 years were summarized. Aymara samples were considered from a total of 55 localities in Bolivia, Peru, and Chile. Gene frequencies were tabulated for 21 polymorphic genetic systems comprising blood groups (AB0, MNSs, P, Rh, Lu, K, Le, Fy, Jk, Di), erythrocyte enzyme groups (AcP, 6PGD, PGM1, AK, ADA, EsD), and plasma protein groups (Hp, Tf, Gc, Gm, Km). Weighted average and range over all Aymara samples were computed for each blood system and compared with corresponding mean value and range in South Amerindians in general. Gene frequency distribution in the Aymara population shows ranges of different orders of magnitude in the 21 blood systems, some of them varying widely. Nevertheless the average gene frequencies for the Aymara are well within the range of values reported for South American Indian populations. The assessment of blood systems in the Aymara revealed that information concerning the Lutheran and HLA systems is scarce or nil up to now. Further studies are needed, especially from Peru on erythrocyte enzyme systems, in order to obtain a more complete picture on the variation of blood system polymorphisms in the Aymara population.

  10. 10-decade wide-range neutron-monitoring system. Final test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, W.K.

    The objective of Project Agreement 49 was to design, fabricate, test, and evaluate under actual nuclear reactor operating conditions, one prototype counting-Campbelling wide-range type thermal neutron flux measurement channel. This report describes the basic system designed for PA 49, and describes and presents the results of tests conducted on the system. Individual module descriptions and schematics are contained in the instruction manual which was issued with the system.

  11. Anti-ship missile tracking with a chirped amplitude modulation ladar

    NASA Astrophysics Data System (ADS)

    Redman, Brian C.; Stann, Barry L.; Ruff, William C.; Giza, Mark M.; Aliberti, Keith; Lawler, William B.

    2004-09-01

    Shipboard infrared search and track (IRST) systems can detect sea-skimming anti-ship missiles at long ranges. Since IRST systems cannot measure range and velocity, they have difficulty distinguishing missiles from slowly moving false targets and clutter. ARL is developing a ladar based on its patented chirped amplitude modulation (AM) technique to provide unambiguous range and velocity measurements of targets handed over to it by the IRST. Using the ladar's range and velocity data, false alarms and clutter objects will be distinguished from valid targets. If the target is valid, it's angular location, range, and velocity, will be used to update the target track until remediation has been effected. By using an array receiver, ARL's ladar can also provide 3D imagery of potential threats in support of force protection. The ladar development program will be accomplished in two phases. In Phase I, currently in progress, ARL is designing and building a breadboard ladar test system for proof-of-principle static platform field tests. In Phase II, ARL will build a brassboard ladar test system that will meet operational goals in shipboard testing against realistic targets. The principles of operation for the chirped AM ladar for range and velocity measurements, the ladar performance model, and the top-level design for the Phase I breadboard are presented in this paper.

  12. 50 CFR 218.173 - Mitigation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Complex shall be promulgated, and sightings shall be entered into the Range Operating System and forwarded... Naval Sea System Command (NAVSEA) Naval Undersea Warfare Center (NUWC) Keyport Range Complex and the... active sonar transmissions when passive acoustic monitoring capabilities are being operated during the...

  13. Calibration validation for the new generation runway visual range system

    DOT National Transportation Integrated Search

    2000-07-01

    A forward scattermeter, consisting of transmitter and receiver heads mounted on a fork, is used in the New Genreration Runway Visual Range (NGRVR) System to assess the clarity of the atmosphere. The scattermeter is calibrated by comparison with refer...

  14. Planar near-field scanning for compact range bistatic radar cross-section measurement. Thesis Final Report

    NASA Technical Reports Server (NTRS)

    Tuhela-Reuning, S. R.; Walton, E. K.

    1991-01-01

    The design, construction, and testing of a low cost, planar scanning system to be used in a compact range environment for bistatic radar cross-section (bistatic RCS) measurement data are discussed. This scanning system is similar to structures used for measuring near-field antenna patterns. A synthetic aperture technique is used for plane wave reception. System testing entailed comparison of measured and theoretical bistatic RCS of a sphere and a right circular cylinder. Bistatic scattering analysis of the ogival target support, target and pedestal interactions, and compact range room was necessary to determine measurement validity.

  15. High dynamic range coding imaging system

    NASA Astrophysics Data System (ADS)

    Wu, Renfan; Huang, Yifan; Hou, Guangqi

    2014-10-01

    We present a high dynamic range (HDR) imaging system design scheme based on coded aperture technique. This scheme can help us obtain HDR images which have extended depth of field. We adopt Sparse coding algorithm to design coded patterns. Then we utilize the sensor unit to acquire coded images under different exposure settings. With the guide of the multiple exposure parameters, a series of low dynamic range (LDR) coded images are reconstructed. We use some existing algorithms to fuse and display a HDR image by those LDR images. We build an optical simulation model and get some simulation images to verify the novel system.

  16. Continuously tunable optical notch filter and band-pass filter systems that cover the visible to near-infrared spectral ranges.

    PubMed

    Jeong, Mi-Yun; Mang, Jin Yeob

    2018-03-10

    Spatially continuous tunable optical notch and band-pass filter systems that cover the visible (VIS) and near-infrared (NIR) spectral ranges from ∼460  nm to ∼1,000  nm are realized by combining left- and right-handed circular cholesteric liquid crystal (CLC) wedge cells with continuous pitch gradient. The notch filter system is polarization independent in all of the spectral ranges. The band-pass filter system, when the left- and right-handed CLCs are arranged in a row, is polarization independent, while when they are arranged at right angles, they are polarization dependent; furthermore, the full-width at half-maximum of the band-pass filter can be changed reversibly from the original bandwidth of 36 nm to 16 nm. Depending on the CLC materials, this strategy could be applied to the UV, VIS, and IR spectral ranges. Due to the high performance in the broad spectral range, cost-effective facile fabrication process, simple mechanical control, and small size, it is expected that our optical tunable filter strategies could become one of the key parts of laser-based Raman spectroscopy, fluorescence, life science devices, optical communication systems, astronomical telescopes, and so forth.

  17. Testing gravity with Lunar Laser Ranging: An update on the APOLLO experiment

    NASA Astrophysics Data System (ADS)

    Battat, James; Colmenares, Nick; Davis, Rodney; Ruixue, Louisa Huang; Murphy, Thomas W., Jr.; Apollo Collaboration

    2017-01-01

    The mystery of dark energy and the incompatibility of quantum mechanics and General Relativity indicate the need for precision experimental probes of gravitational physics. The Earth-Moon-Sun system is a fertile laboratory for such tests. The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) makes optical range measurements to retro-reflectors on the Moon with one millimeter precision. These measurements of the lunar orbit enable incisive constraints on gravitational phenomena such as the Strong Equivalence Principle and dG / dt (among others). Until now, the APOLLO team had not been able to assess the accuracy of our data, in large part because known limitations to lunar range models ensure data-model residuals at the centimeter scale. To directly measure the APOLLO system timing accuracy, we have built an Absolute timing Calibration System (ACS) that delivers photons to our detector at known, stable time intervals using a pulsed fiber laser locked to a cesium frequency standard. This scheme provides real-time calibration of the APOLLO system timing, synchronous with the range measurements. We installed the calibration system in August, 2016. In this talk, we will describe the ACS design, and present present preliminary results from the ACS calibration campaign. We acknowledge the support of both NSF and NASA

  18. Toward 1-mm depth precision with a solid state full-field range imaging system

    NASA Astrophysics Data System (ADS)

    Dorrington, Adrian A.; Carnegie, Dale A.; Cree, Michael J.

    2006-02-01

    Previously, we demonstrated a novel heterodyne based solid-state full-field range-finding imaging system. This system is comprised of modulated LED illumination, a modulated image intensifier, and a digital video camera. A 10 MHz drive is provided with 1 Hz difference between the LEDs and image intensifier. A sequence of images of the resulting beating intensifier output are captured and processed to determine phase and hence distance to the object for each pixel. In a previous publication, we detailed results showing a one-sigma precision of 15 mm to 30 mm (depending on signal strength). Furthermore, we identified the limitations of the system and potential improvements that were expected to result in a range precision in the order of 1 mm. These primarily include increasing the operating frequency and improving optical coupling and sensitivity. In this paper, we report on the implementation of these improvements and the new system characteristics. We also comment on the factors that are important for high precision image ranging and present configuration strategies for best performance. Ranging with sub-millimeter precision is demonstrated by imaging a planar surface and calculating the deviations from a planar fit. The results are also illustrated graphically by imaging a garden gnome.

  19. Evaluation of Hematocrit Influence on Self-Monitoring of Blood Glucose Based on ISO 15197:2013: Comparison of a Novel System With Five Systems With Different Hematocrit Ranges.

    PubMed

    Hattemer, Andrew; Wardat, Sami

    2018-03-01

    ISO 15197:2013 recommends testing procedures and acceptance criteria for the evaluation of influence quantities such as hematocrit on measurement results with systems for self-monitoring of blood glucose (SMBG). In this study, hematocrit influence was evaluated for a novel SMBG system (system A) and five other systems with different hematocrit ranges based on ISO 15197:2013. Test procedures were performed with one test strip lot for each system. Each system was tested within the hematocrit range indicated in the manufacturer's labeling (system A: 10-65%, B: 15-65%, C: 20-60%, D: 35-60%, E: 30-60%, F: 30-55%). According to ISO 15197:2013, clause 6.4.2, venous blood samples were used for the evaluation of hematocrit influence. The evaluation was performed for three glucose concentration categories (30-50 mg/dL, 96-144 mg/dL, and 280-420 mg/dL). For each glucose concentration category, at least five different hematocrit levels were investigated. The novel system A and systems B, E, and F complied with the tested lot with the defined criteria and showed ≤10 mg/dL and ≤10% difference between the test sample and the respective control sample with a hematocrit value of 42% ± 2% for BG concentrations <100 mg/dL and ≥100 mg/dL, respectively. Two systems showed >10% difference at glucose concentrations ≥100 mg/dL. Remarkable hematocrit influence within the labeled hematocrit range was obtained in two systems with the tested reagent system lot. Adequate SMBG systems should be carefully chosen by patients and their health care professionals, particularly for patients with increased and decreased hematocrit values.

  20. 50 CFR 30.2 - Disposition of surplus range animals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Disposition of surplus range animals. 30.2... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.2 Disposition of surplus range animals. Disposition shall be made only during regularly scheduled disposal...

  1. 50 CFR 30.2 - Disposition of surplus range animals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Disposition of surplus range animals. 30.2... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.2 Disposition of surplus range animals. Disposition shall be made only during regularly scheduled disposal...

  2. 50 CFR 30.2 - Disposition of surplus range animals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Disposition of surplus range animals. 30.2... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.2 Disposition of surplus range animals. Disposition shall be made only during regularly scheduled disposal...

  3. 50 CFR 30.2 - Disposition of surplus range animals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Disposition of surplus range animals. 30.2... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.2 Disposition of surplus range animals. Disposition shall be made only during regularly scheduled disposal...

  4. 50 CFR 30.2 - Disposition of surplus range animals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Disposition of surplus range animals. 30.2... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM RANGE AND FERAL ANIMAL MANAGEMENT Range Animals § 30.2 Disposition of surplus range animals. Disposition shall be made only during regularly scheduled disposal...

  5. Results of the long range position-determining system tests. [Field Army system

    NASA Technical Reports Server (NTRS)

    Rhode, F. W.

    1973-01-01

    The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

  6. Video-rate or high-precision: a flexible range imaging camera

    NASA Astrophysics Data System (ADS)

    Dorrington, Adrian A.; Cree, Michael J.; Carnegie, Dale A.; Payne, Andrew D.; Conroy, Richard M.; Godbaz, John P.; Jongenelen, Adrian P. P.

    2008-02-01

    A range imaging camera produces an output similar to a digital photograph, but every pixel in the image contains distance information as well as intensity. This is useful for measuring the shape, size and location of objects in a scene, hence is well suited to certain machine vision applications. Previously we demonstrated a heterodyne range imaging system operating in a relatively high resolution (512-by-512) pixels and high precision (0.4 mm best case) configuration, but with a slow measurement rate (one every 10 s). Although this high precision range imaging is useful for some applications, the low acquisition speed is limiting in many situations. The system's frame rate and length of acquisition is fully configurable in software, which means the measurement rate can be increased by compromising precision and image resolution. In this paper we demonstrate the flexibility of our range imaging system by showing examples of high precision ranging at slow acquisition speeds and video-rate ranging with reduced ranging precision and image resolution. We also show that the heterodyne approach and the use of more than four samples per beat cycle provides better linearity than the traditional homodyne quadrature detection approach. Finally, we comment on practical issues of frame rate and beat signal frequency selection.

  7. A study of 35-ghz radar-assisted orbital maneuvering vehicle/space telescope docking

    NASA Technical Reports Server (NTRS)

    Mcdonald, M. W.

    1986-01-01

    An experiment was conducted to study the effects of measuring range and range rate information from a complex radar target (a one-third scale model of the Edwin P. Hubble Space Telescope). The radar ranging system was a 35-GHz frequency-modulated continuous wave unit developed in the Communication Systems Branch of the Information and Electronic Systems Laboratory at Marshall Space Flight Cneter. Measurements were made over radar-to-target distances of 5 meters to 15 meters to simulate the close distance realized in the final stages of space vehicle docking. The Space Telescope model target was driven by an antenna positioner through a range of azimuth and elevation (pitch) angles to present a variety of visual aspects of the aft end to the radar. Measurements were obtained with and without a cube corner reflector mounted in the center of the aft end of the model. The results indicate that range and range rate measurements are performed significantly more accurately with the cooperative radar reflector affixed. The results further reveal that range rate (velocity) can be measured accurately enough to support the required soft docking with the Space Telescope.

  8. 33 CFR 164.37 - Equipment: Vessels of 10,000 gross tons or more.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to the radar system under § 164.35(a), a second marine radar system that operates independently of... subject to 46 U.S.C. 3708, the dual radar system required by this part must have a short range capability and a long range capability; and each radar must have true north features consisting of a display that...

  9. 33 CFR 164.37 - Equipment: Vessels of 10,000 gross tons or more.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to the radar system under § 164.35(a), a second marine radar system that operates independently of... subject to 46 U.S.C. 3708, the dual radar system required by this part must have a short range capability and a long range capability; and each radar must have true north features consisting of a display that...

  10. High speed high dynamic range high accuracy measurement system

    DOEpatents

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng

    2016-11-29

    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  11. 33 CFR 164.37 - Equipment: Vessels of 10,000 gross tons or more.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to the radar system under § 164.35(a), a second marine radar system that operates independently of... subject to 46 U.S.C. 3708, the dual radar system required by this part must have a short range capability and a long range capability; and each radar must have true north features consisting of a display that...

  12. 33 CFR 164.37 - Equipment: Vessels of 10,000 gross tons or more.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to the radar system under § 164.35(a), a second marine radar system that operates independently of... subject to 46 U.S.C. 3708, the dual radar system required by this part must have a short range capability and a long range capability; and each radar must have true north features consisting of a display that...

  13. 33 CFR 164.37 - Equipment: Vessels of 10,000 gross tons or more.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to the radar system under § 164.35(a), a second marine radar system that operates independently of... subject to 46 U.S.C. 3708, the dual radar system required by this part must have a short range capability and a long range capability; and each radar must have true north features consisting of a display that...

  14. Atmospheric turbulence and sensor system effects on biometric algorithm performance

    NASA Astrophysics Data System (ADS)

    Espinola, Richard L.; Leonard, Kevin R.; Byrd, Kenneth A.; Potvin, Guy

    2015-05-01

    Biometric technologies composed of electro-optical/infrared (EO/IR) sensor systems and advanced matching algorithms are being used in various force protection/security and tactical surveillance applications. To date, most of these sensor systems have been widely used in controlled conditions with varying success (e.g., short range, uniform illumination, cooperative subjects). However the limiting conditions of such systems have yet to be fully studied for long range applications and degraded imaging environments. Biometric technologies used for long range applications will invariably suffer from the effects of atmospheric turbulence degradation. Atmospheric turbulence causes blur, distortion and intensity fluctuations that can severely degrade image quality of electro-optic and thermal imaging systems and, for the case of biometrics technology, translate to poor matching algorithm performance. In this paper, we evaluate the effects of atmospheric turbulence and sensor resolution on biometric matching algorithm performance. We use a subset of the Facial Recognition Technology (FERET) database and a commercial algorithm to analyze facial recognition performance on turbulence degraded facial images. The goal of this work is to understand the feasibility of long-range facial recognition in degraded imaging conditions, and the utility of camera parameter trade studies to enable the design of the next generation biometrics sensor systems.

  15. Maximally random discrete-spin systems with symmetric and asymmetric interactions and maximally degenerate ordering

    NASA Astrophysics Data System (ADS)

    Atalay, Bora; Berker, A. Nihat

    2018-05-01

    Discrete-spin systems with maximally random nearest-neighbor interactions that can be symmetric or asymmetric, ferromagnetic or antiferromagnetic, including off-diagonal disorder, are studied, for the number of states q =3 ,4 in d dimensions. We use renormalization-group theory that is exact for hierarchical lattices and approximate (Migdal-Kadanoff) for hypercubic lattices. For all d >1 and all noninfinite temperatures, the system eventually renormalizes to a random single state, thus signaling q ×q degenerate ordering. Note that this is the maximally degenerate ordering. For high-temperature initial conditions, the system crosses over to this highly degenerate ordering only after spending many renormalization-group iterations near the disordered (infinite-temperature) fixed point. Thus, a temperature range of short-range disorder in the presence of long-range order is identified, as previously seen in underfrustrated Ising spin-glass systems. The entropy is calculated for all temperatures, behaves similarly for ferromagnetic and antiferromagnetic interactions, and shows a derivative maximum at the short-range disordering temperature. With a sharp immediate contrast of infinitesimally higher dimension 1 +ɛ , the system is as expected disordered at all temperatures for d =1 .

  16. Studies on Arabidopsis athak5, atakt1 double mutants disclose the range of concentrations at which AtHAK5, AtAKT1 and unknown systems mediate K uptake.

    PubMed

    Rubio, Francisco; Alemán, Fernando; Nieves-Cordones, Manuel; Martínez, Vicente

    2010-06-01

    The high-affinity K(+) transporter AtHAK5 and the inward-rectifier K(+) channel AtAKT1 have been described to contribute to K(+) uptake in Arabidopsis thaliana. Studies with T-DNA insertion lines showed that both systems participate in the high-affinity range of concentrations and only AtAKT1 in the low-affinity range. However the contribution of other systems could not be excluded with the information and plant material available. The results presented here with a double knock-out athak5, atakt1 mutant show that AtHAK5 is the only system mediating K(+) uptake at concentrations below 0.01 mM. In the range between 0.01 and 0.05 mM K(+) AtHAK5 and AtAKT1 are the only contributors to K(+) acquisition. At higher K(+) concentrations, unknown systems come into operation and participate together with AtAKT1 in low-affinity K(+) uptake. These systems can supply sufficient K(+) to promote plant growth even in the absence of AtAKT1 or in the presence of 10 mM K(+) where AtAKT1 is not essential.

  17. Precision improvement of frequency-modulated continuous-wave laser ranging system with two auxiliary interferometers

    NASA Astrophysics Data System (ADS)

    Shi, Guang; Wang, Wen; Zhang, Fumin

    2018-03-01

    The measurement precision of frequency-modulated continuous-wave (FMCW) laser distance measurement should be proportional to the scanning range of the tunable laser. However, the commercial external cavity diode laser (ECDL) is not an ideal tunable laser source in practical applications. Due to the unavoidable mode hopping and scanning nonlinearity of the ECDL, the measurement precision of FMCW laser distance measurements can be substantially affected. Therefore, an FMCW laser ranging system with two auxiliary interferometers is proposed in this paper. Moreover, to eliminate the effects of ECDL, the frequency-sampling method and mode hopping influence suppression method are employed. Compared with a fringe counting interferometer, this FMCW laser ranging system has a measuring error of ± 20 μm at the distance of 5.8 m.

  18. Long-ranged Fermi-Pasta-Ulam systems in thermal contact: Crossover from q-statistics to Boltzmann-Gibbs statistics

    NASA Astrophysics Data System (ADS)

    Bagchi, Debarshee; Tsallis, Constantino

    2017-04-01

    The relaxation to equilibrium of two long-range-interacting Fermi-Pasta-Ulam-like models (β type) in thermal contact is numerically studied. These systems, with different sizes and energy densities, are coupled to each other by a few thermal contacts which are short-range harmonic springs. By using the kinetic definition of temperature, we compute the time evolution of temperature and energy density of the two systems. Eventually, for some time t >teq, the temperature and energy density of the coupled system equilibrate to values consistent with standard Boltzmann-Gibbs thermostatistics. The equilibration time teq depends on the system size N as teq ∼Nγ where γ ≃ 1.8. We compute the velocity distribution P (v) of the oscillators of the two systems during the relaxation process. We find that P (v) is non-Gaussian and is remarkably close to a q-Gaussian distribution for all times before thermal equilibrium is reached. During the relaxation process we observe q > 1 while close to t =teq the value of q converges to unity and P (v) approaches a Gaussian. Thus the relaxation phenomenon in long-ranged systems connected by a thermal contact can be generically described as a crossover from q-statistics to Boltzmann-Gibbs statistics.

  19. The Quaternary thrust system of the northern Alaska Range

    USGS Publications Warehouse

    Bemis, Sean P.; Carver, Gary A.; Koehler, Richard D.

    2012-01-01

    The framework of Quaternary faults in Alaska remains poorly constrained. Recent studies in the Alaska Range north of the Denali fault add significantly to the recognition of Quaternary deformation in this active orogen. Faults and folds active during the Quaternary occur over a length of ∼500 km along the northern flank of the Alaska Range, extending from Mount McKinley (Denali) eastward to the Tok River valley. These faults exist as a continuous system of active structures, but we divide the system into four regions based on east-west changes in structural style. At the western end, the Kantishna Hills have only two known faults but the highest rate of shallow crustal seismicity. The western northern foothills fold-thrust belt consists of a 50-km-wide zone of subparallel thrust and reverse faults. This broad zone of deformation narrows to the east in a transition zone where the range-bounding fault of the western northern foothills fold-thrust belt terminates and displacement occurs on thrust and/or reverse faults closer to the Denali fault. The eastern northern foothills fold-thrust belt is characterized by ∼40-km-long thrust fault segments separated across left-steps by NNE-trending left-lateral faults. Altogether, these faults accommodate much of the topographic growth of the northern flank of the Alaska Range.Recognition of this thrust fault system represents a significant concern in addition to the Denali fault for infrastructure adjacent to and transecting the Alaska Range. Although additional work is required to characterize these faults sufficiently for seismic hazard analysis, the regional extent and structural character should require the consideration of the northern Alaska Range thrust system in regional tectonic models.

  20. NASA ground-based and space-based laser ranging systems

    NASA Technical Reports Server (NTRS)

    Fitzmaurice, M. W.

    1978-01-01

    Laser ranging is expected to help unlock the mysteries of the earthquake phenomenon by producing unique results of crustal motions of the Earth. The current state of the art and future projections are presented, including principal applications and characteristics of typical systems.

  1. Evaluation of Epidemic Intelligence Systems Integrated in the Early Alerting and Reporting Project for the Detection of A/H5N1 Influenza Events

    PubMed Central

    Barboza, Philippe; Vaillant, Laetitia; Mawudeku, Abla; Nelson, Noele P.; Hartley, David M.; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Yangarber, Roman; Astagneau, Pascal; on behalf of the Early Alerting, Reporting Project of the Global Health Security Initiative

    2013-01-01

    The objective of Web-based expert epidemic intelligence systems is to detect health threats. The Global Health Security Initiative (GHSI) Early Alerting and Reporting (EAR) project was launched to assess the feasibility and opportunity for pooling epidemic intelligence data from seven expert systems. EAR participants completed a qualitative survey to document epidemic intelligence strategies and to assess perceptions regarding the systems performance. Timeliness and sensitivity were rated highly illustrating the value of the systems for epidemic intelligence. Weaknesses identified included representativeness, completeness and flexibility. These findings were corroborated by the quantitative analysis performed on signals potentially related to influenza A/H5N1 events occurring in March 2010. For the six systems for which this information was available, the detection rate ranged from 31% to 38%, and increased to 72% when considering the virtual combined system. The effective positive predictive values ranged from 3% to 24% and F1-scores ranged from 6% to 27%. System sensitivity ranged from 38% to 72%. An average difference of 23% was observed between the sensitivities calculated for human cases and epizootics, underlining the difficulties in developing an efficient algorithm for a single pathology. However, the sensitivity increased to 93% when the virtual combined system was considered, clearly illustrating complementarities between individual systems. The average delay between the detection of A/H5N1 events by the systems and their official reporting by WHO or OIE was 10.2 days (95% CI: 6.7–13.8). This work illustrates the diversity in implemented epidemic intelligence activities, differences in system's designs, and the potential added values and opportunities for synergy between systems, between users and between systems and users. PMID:23472077

  2. Evaluation of epidemic intelligence systems integrated in the early alerting and reporting project for the detection of A/H5N1 influenza events.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Mawudeku, Abla; Nelson, Noele P; Hartley, David M; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Yangarber, Roman; Astagneau, Pascal

    2013-01-01

    The objective of Web-based expert epidemic intelligence systems is to detect health threats. The Global Health Security Initiative (GHSI) Early Alerting and Reporting (EAR) project was launched to assess the feasibility and opportunity for pooling epidemic intelligence data from seven expert systems. EAR participants completed a qualitative survey to document epidemic intelligence strategies and to assess perceptions regarding the systems performance. Timeliness and sensitivity were rated highly illustrating the value of the systems for epidemic intelligence. Weaknesses identified included representativeness, completeness and flexibility. These findings were corroborated by the quantitative analysis performed on signals potentially related to influenza A/H5N1 events occurring in March 2010. For the six systems for which this information was available, the detection rate ranged from 31% to 38%, and increased to 72% when considering the virtual combined system. The effective positive predictive values ranged from 3% to 24% and F1-scores ranged from 6% to 27%. System sensitivity ranged from 38% to 72%. An average difference of 23% was observed between the sensitivities calculated for human cases and epizootics, underlining the difficulties in developing an efficient algorithm for a single pathology. However, the sensitivity increased to 93% when the virtual combined system was considered, clearly illustrating complementarities between individual systems. The average delay between the detection of A/H5N1 events by the systems and their official reporting by WHO or OIE was 10.2 days (95% CI: 6.7-13.8). This work illustrates the diversity in implemented epidemic intelligence activities, differences in system's designs, and the potential added values and opportunities for synergy between systems, between users and between systems and users.

  3. Ultrasonic ranging for the oculometer

    NASA Technical Reports Server (NTRS)

    Guy, W. J.

    1981-01-01

    Ultrasonic tracking techniques are investigated for an oculometer. Two methods are reported in detail. The first is based on measurements of time from the start of a transmit burst to a received echo. Knowing the sound velocity, distance can be calculated. In the second method, a continuous signal is transmitted. Target movement causes phase shifting of the echo. By accumulating these phase shifts, tracking from a set point can be achieved. Both systems have problems with contoured targets, but work well on flat plates and the back of a human head. Also briefly reported is an evaluation of an ultrasonic ranging system. Interface circuits make this system compatible with the echo time design. While the system is consistently accurate, it has a beam too narrow for oculometer use. Finally, comments are provided on a tracking system using the Doppler frequency shift to give range data.

  4. Flowmeter for pressure-driven chromatography systems

    DOEpatents

    Paul, Phillip H.; Arnold, Don W.

    2003-01-01

    A flowmeter for accurately measuring the flowrate of fluids in high pressure chromatography systems. The flowmeter is a porous bed of a material, the porous bed having a porosity in the range of about 0.1 to 0.6 and a pore size in the range of about 50 nm to 1 .mu.m, disposed between a high pressure pumping means and a chromatography column. The flowmeter is provided with pressure measuring means at both the inlet and outlet of the porous bed for measuring the pressure drop through the porous bed. This flowmeter system provides not only the ability to measure accurately flowrates in the range of .mu.L/min to nL/min but also to provide a signal that can be used for a servo loop or feedback control system for high pressure pumping systems.

  5. Flowmeter for pressure-driven chromatography systems

    DOEpatents

    Paul, Phillip H.; Arnold, Don W.

    2002-01-01

    A flowmeter for accurately measuring the flowrate of fluids in high pressure chromatography systems. The flowmeter is a porous bed of a material, the porous bed having a porosity in the range of about 0.1 to 0.6 and a pore size in the range of about 50 nm to 1 .mu.m, disposed between a high pressure pumping means and a chromatography column. The flowmeter is provided with pressure measuring means at both the inlet and outlet of the porous bed for measuring the pressure drop through the porous bed. This flowmeter system provides not only the ability to measure accurately flowrates in the range of .mu.L/min to nL/min but also to provide a signal that can be used for a servo loop or feedback control system for high pressure pumping systems.

  6. Selective encapsulation by Janus particles

    NASA Astrophysics Data System (ADS)

    Li, Wei; Ruth, Donovan; Gunton, James D.; Rickman, Jeffrey M.

    2015-06-01

    We employ Monte Carlo simulation to examine encapsulation in a system comprising Janus oblate spheroids and isotropic spheres. More specifically, the impact of variations in temperature, particle size, inter-particle interaction range, and strength is examined for a system in which the spheroids act as the encapsulating agents and the spheres as the encapsulated guests. In this picture, particle interactions are described by a quasi-square-well patch model. This study highlights the environmental adaptation and selectivity of the encapsulation system to changes in temperature and guest particle size, respectively. Moreover, we identify an important range in parameter space where encapsulation is favored, as summarized by an encapsulation map. Finally, we discuss the generalization of our results to systems having a wide range of particle geometries.

  7. Personal Rotorcraft Design and Performance with Electric Hybridization

    NASA Technical Reports Server (NTRS)

    Snyder, Christopher A.

    2017-01-01

    Recent and projected improvements for more or all-electric aviation propulsion systems can enable greater personal mobility, while also reducing environmental impact (noise and emissions). However, all-electric energy storage capability is significantly less than present, hydrocarbon-fueled systems. A system study was performed exploring design and performance assuming hybrid propulsion ranging from traditional hydrocarbon-fueled cycles (gasoline Otto and diesel) to all-electric systems using electric motors generators, with batteries for energy storage and load leveling. Study vehicles were a conventional, single-main rotor (SMR) helicopter and an advanced vertical takeoff and landing (VTOL) aircraft. Vehicle capability was limited to two or three people (including pilot or crew); the design range for the VTOL aircraft was set to 150 miles (about one hour total flight). Search and rescue (SAR), loiter, and cruise-dominated missions were chosen to illustrate each vehicle and degree of hybrid propulsion strengths and weaknesses. The traditional, SMR helicopter is a hover-optimized design; electric hybridization was performed assuming a parallel hybrid approach by varying degree of hybridization. Many of the helicopter hybrid propulsion combinations have some mission capabilities that might be effective for short range or on-demand mobility missions. However, even for 30 year technology electrical components, all hybrid propulsion systems studied result in less available fuel, lower maximum range, and reduced hover and loiter duration than the baseline vehicle. Results for the VTOL aircraft were more encouraging. Series hybrid combinations reflective of near-term systems could improve range and loiter duration by 30. Advanced, higher performing series hybrid combinations could double or almost triple the VTOL aircrafts range and loiter duration. Additional details on the study assumptions and work performed are given, as well as suggestions for future study effort.

  8. Study of the liquid vapor equilibrium in the bromine-hydrobromic acid-water system

    NASA Technical Reports Server (NTRS)

    Benizri, R.; Lessart, P.; Courvoisier, P.

    1984-01-01

    A glass ebullioscope was built and at atmospheric pressure, liquid-vapor equilibria relative to the Br2-HBr-H2O system, in the concentration range of interest for evaluation of the Mark 13 cycle was studied. Measurements were performed for the brome-azeotrope (HBr-H2O) pseudo-binary system and for the ternary system at temperatures lower than 125 C and in the bromine concentration range up to 13% wt.

  9. Prompt Global Strike: China and the Spear

    DTIC Science & Technology

    2014-04-01

    longer range systems that are embedded in a larger system of advanced C4ISR is also evidenced by studies that detail China’s long-range hypersonic...to view U.S. PGS as a threat to Beijing’s conventional and nuclear weapons systems , as well as its command and control centers. With the breadth of...U.S. platforms defined as PGS-related systems in China, its analysts have not ruled out their delivery of nuclear weapons. Despite its criticism of

  10. Electric Propulsion Options for 10 kW Class Earth-Space Missions

    NASA Technical Reports Server (NTRS)

    Patterson, M. J.; Curran, Francis M.

    1989-01-01

    Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment were evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA 2 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10 (exp 7) to 2.1x10 (exp 7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA 2 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10 (exp 6) to 3.6x10 (exp 6) N-s, and approximately 662 to 1072 m/s, respectively.

  11. Telemetric signal-driven servocontrol of renal perfusion pressure in acute and chronic rat experiments

    PubMed Central

    Xia, Min; Li, Pin-Lan; Li, Ningjun

    2008-01-01

    The present study was designed to take advantage of telemetry data acquisition and develop an easy and reliable system to servocontrol renal perfusion pressure (RPP). Digitized pressure signals from lower abdominal aorta in rats, reflecting RPP, was obtained by a telemetry device and dynamically exported into an Excel worksheet. A computer program (LabVIEW) compared the RPP data with a preselected pressure range and drove a bidirectional syringe pump to control the inflation of a vascular occluder around the aorta above renal arteries. When RPP was higher than the preselected range, the syringe pump inflated the occluder and decreased RPP, and vice versa. If RPP was within range, there was no action. In this way, RPP was servocontrolled within the desired range. In experiments with norepinephrine- or ANG II-induced acute increases in systemic arterial pressure (120–145 mmHg), the system controlled RPP at a constant range of 100–105 mmHg within 30–50 s and differentiated the pressure-dependent and -independent effects on renal functions. In Dahl S rats with high-salt-induced hypertension, this system maintained RPP at 100–120 mmHg over 10 days, while systemic arterial pressures were 150 ± 5.9 mmHg in uncontrolled animals. This system also has the ability of simultaneity and multiplexing to control multiple animals. Our results suggest that this is an effective and reliable system to servocontrol RPP, which can be easily established with general computer knowledge. This system provides a powerful tool and may greatly facilitate the studies in pressure-dependent/-independent effects of a variety of cardiovascular factors. PMID:18815205

  12. MO-F-CAMPUS-T-04: Utilization of Optical Dosimeter for Modulated Spot-Scanning Particle Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsi, W; Li, Y; Huang, Z

    Purpose: To present the utilization of an optical dosimeter for modulated spot-scanning carbon-ion and proton beams during the acceptance test of Siemens IONTRIS system. Method and Materials: An optical dosimeter using phosphor scintillation was developed to map and interactively analyze the shapes and sizes of spots over 190 energies for ProTom modulated-scanning system. The dose response to proton had been characterized with proper pixel calibration at ProTom system. The dose response was further studied at 0.7 cm depths by uniform 8cm in-diameter fields of 424.89 MeV/u (E290) carbon-ions and 215.18MeV (E282) protons at IONTRIS system. The virtual source axial distancesmore » (vSAD) of carbonions and protons of IONTRIS system was investigated by measuring either variations of spot position or field size at five different locations to Isocenter. By measuring lateral profiles of uniform doses with varied thin-thicknesses of chest-board pattern and placing the scintillation plate at near to the distal edge, range variations at different off-axis-distances (rOAD) were examined. Relative accuracy and reproducibility of beam range were measured for three beam ranges with a ramping block at front of scintillation plate. Results: Similar dose response was observed for high energies of carbon ions and protons. Mean vSAD at X and Y axes were 744.1 cm and 807.4cm with deviation of 7.4cm and 7.7cm, respectively. Variation of rOAD was within 0.35 mm over 10cm for both protons and carbon ions. Accuracy of measuring relative distal range using the ramping block was 0.2mm. Measured range over repeated three times for each range were within 0.25mm at same room, and within 1.0mm between four rooms. Conclusions: The optical dosimeter could efficiently measure the virtual source distance. And, to measure small range variation at different off-axial locations, and for the relative beam range between rooms during acceptance test of a modulated spot-scanning particle system.« less

  13. Satellite tracking and Earth dynamics research programs

    NASA Technical Reports Server (NTRS)

    Pearlman, M. R.

    1984-01-01

    Following an upgrading program, ranging performance capabilities of a satellite-tracking pulsed laser system were assessed in terms of range accuracy, range noise, data yield, and reliability. With a shorter laser pulse duration (2.5 to 3.0 NSEC) and a new analog pulse processing system, the systematic range errors were reduced to 3 to 5 cm and range noise was reduced to 5 to 16 cm and range noise was reduced to 5 to 15 cm on Starlette and BE-C, and 10 to 18 cm on LAGEOS. Maximum pulse repetition rate was increased to 30 pulses per minute and significant improvement was made in signal to noise ratio by installing a 3 A interference filter and by reducing the range gate window to 200 to 400 nsec. The solution to a problem involving leakage of a fraction of the laser oscillator pulse through the pulse chopper was outlined.

  14. System and Method for Scan Range Gating

    NASA Technical Reports Server (NTRS)

    Lindemann, Scott (Inventor); Zuk, David M. (Inventor)

    2017-01-01

    A system for scanning light to define a range gated signal includes a pulsed coherent light source that directs light into the atmosphere, a light gathering instrument that receives the light modified by atmospheric backscatter and transfers the light onto an image plane, a scanner that scans collimated light from the image plane to form a range gated signal from the light modified by atmospheric backscatter, a control circuit that coordinates timing of a scan rate of the scanner and a pulse rate of the pulsed coherent light source so that the range gated signal is formed according to a desired range gate, an optical device onto which an image of the range gated signal is scanned, and an interferometer to which the image of the range gated signal is directed by the optical device. The interferometer is configured to modify the image according to a desired analysis.

  15. Structural properties of medium-range order in CuNiZr alloy

    NASA Astrophysics Data System (ADS)

    Gao, Tinghong; Hu, Xuechen; Xie, Quan; Li, Yidan; Ren, Lei

    2017-10-01

    The evolution characteristics of icosahedral clusters during the rapid solidification of Cu50Ni10Zr40 alloy at cooling rate of 1011 K s-1 are investigated based on molecular dynamics simulations. The structural properties of the short-range order and medium-range order of Cu50Ni10Zr40 alloy are analyzed by several structural characterization methods. The results reveal that the icosahedral clusters are the dominant short-range order structure, and that they assemble themselves into medium-range order by interpenetrating connections. The different morphologies of medium-range order are found in the system and include chain, triangle, tetrahedral, and their combination structures. The tetrahedral morphologies of medium-range order have excellent structural stability with decreasing temperature. The Zr atoms are favorable to form longer chains, while the Cu atoms are favorable to form shorter chains in the system. Those chains interlocked with each other to improve the structural stability.

  16. The Use of a Satellite Communications System for Command and Control of the National Aeronautics and Space Administration Surrogate Unmanned Aerial System Research Aircraft

    NASA Technical Reports Server (NTRS)

    Howell, Charles T.; Jones, Frank; Hutchinson, Brian; Joyce, Claude; Nelson, Skip; Melum, Mike

    2017-01-01

    The NASA Langley Research Center has transformed a Cirrus Design SR22 general aviation (GA) aircraft into an Unmanned Aerial Systems (UAS) Surrogate research aircraft which has served for several years as a platform for unmanned systems research and development. The aircraft is manned with a Safety Pilot and a Research Systems Operator (RSO) that allows for flight operations almost any-where in the national airspace system (NAS) without the need for a Federal Aviation Administration (FAA) Certificate of Authorization (COA). The UAS Surrogate can be remotely controlled from a modular, transportable ground control station (GCS) like a true UAS. Ground control of the aircraft is accomplished by the use of data links that allow the two-way passage of the required data to control the aircraft and provide the GCS with situational awareness. The original UAS Surrogate data-link system was composed of redundant very high frequency (VHF) data radio modems with a maximum range of approximately 40 nautical miles. A new requirement was developed to extend this range beyond visual range (BVR). This new requirement led to the development of a satellite communications system that provided the means to command and control the UAS Surrogate at ranges beyond the limits of the VHF data links. The system makes use of the Globalstar low earth orbit (LEO) satellite communications system. This paper will provide details of the development, implementation, and flight testing of the satellite data communications system on the UAS Surrogate research aircraft.

  17. Design of large zoom for visible and infrared optical system in hemisphere space

    NASA Astrophysics Data System (ADS)

    Xing, Yang-guang; Li, Lin; Zhang, Juan

    2018-01-01

    In the field of space optical, the application of advanced optical instruments for related target detection and identification has become an advanced technology in modern optics. In order to complete the task of search in wide field of view and detailed investigation in small field of view, it is inevitable to use the structure of the zoom system to achieve a better observation for important targets. The innovation of this paper lies in using the zoom optical system in space detection, which achieve firstly military needs of searched target in the large field of view and recognized target in the small field of view. At the same time, this paper also completes firstly the design of variable focus optical detection system in the range of hemisphere space, the zoom optical system is working in the range of visible and infrared wavelengths, the perspective angle reaches 360 ° and the zoom ratio of the visible system is up to 15. The visible system has a zoom range of 60-900 mm, a detection band of 0.48-0.70μm, and a F-number of 2.0 to 5.0. The infrared system has a zoom range of 150 900mm, a detection band of 8-12μm, and a F-number of 1.2 to 3.0. The MTF of the visible zoom system is above 0.4 at spatial frequency of 45 lp / mm, and the infrared zoom system is above 0.4 at spatial frequency of 11 lp / mm. The design results show that the system has a good image quality.

  18. Dense range map reconstruction from a versatile robotic sensor system with an active trinocular vision and a passive binocular vision.

    PubMed

    Kim, Min Young; Lee, Hyunkee; Cho, Hyungsuck

    2008-04-10

    One major research issue associated with 3D perception by robotic systems is the creation of efficient sensor systems that can generate dense range maps reliably. A visual sensor system for robotic applications is developed that is inherently equipped with two types of sensor, an active trinocular vision and a passive stereo vision. Unlike in conventional active vision systems that use a large number of images with variations of projected patterns for dense range map acquisition or from conventional passive vision systems that work well on specific environments with sufficient feature information, a cooperative bidirectional sensor fusion method for this visual sensor system enables us to acquire a reliable dense range map using active and passive information simultaneously. The fusion algorithms are composed of two parts, one in which the passive stereo vision helps active vision and the other in which the active trinocular vision helps the passive one. The first part matches the laser patterns in stereo laser images with the help of intensity images; the second part utilizes an information fusion technique using the dynamic programming method in which image regions between laser patterns are matched pixel-by-pixel with help of the fusion results obtained in the first part. To determine how the proposed sensor system and fusion algorithms can work in real applications, the sensor system is implemented on a robotic system, and the proposed algorithms are applied. A series of experimental tests is performed for a variety of configurations of robot and environments. The performance of the sensor system is discussed in detail.

  19. Photovoltaics and solar thermal conversion to electricity - Status and prospects

    NASA Technical Reports Server (NTRS)

    Alper, M. E.

    1979-01-01

    Photovoltaic power system technology development includes flat-plate silicon solar arrays and concentrating solar cell systems, which use silicon and other cell materials such as gallium arsenide. System designs and applications include small remote power systems ranging in size from tens of watts to tens of kilowatts, intermediate load-center applications ranging in size from tens to hundreds of kilowatts, and large central plant installations, as well as grid-connected rooftop applications. The thermal conversion program is concerned with large central power systems and small power applications.

  20. Video Guidance Sensor System With Integrated Rangefinding

    NASA Technical Reports Server (NTRS)

    Book, Michael L. (Inventor); Bryan, Thomas C. (Inventor); Howard, Richard T. (Inventor); Roe, Fred Davis, Jr. (Inventor); Bell, Joseph L. (Inventor)

    2006-01-01

    A video guidance sensor system for use, p.g., in automated docking of a chase vehicle with a target vehicle. The system includes an integrated rangefinder sub-system that uses time of flight measurements to measure range. The rangefinder sub-system includes a pair of matched photodetectors for respectively detecting an output laser beam and return laser beam, a buffer memory for storing the photodetector outputs, and a digitizer connected to the buffer memory and including dual amplifiers and analog-to-digital converters. A digital signal processor processes the digitized output to produce a range measurement.

  1. Computing physical properties with quantum Monte Carlo methods with statistical fluctuations independent of system size.

    PubMed

    Assaraf, Roland

    2014-12-01

    We show that the recently proposed correlated sampling without reweighting procedure extends the locality (asymptotic independence of the system size) of a physical property to the statistical fluctuations of its estimator. This makes the approach potentially vastly more efficient for computing space-localized properties in large systems compared with standard correlated methods. A proof is given for a large collection of noninteracting fragments. Calculations on hydrogen chains suggest that this behavior holds not only for systems displaying short-range correlations, but also for systems with long-range correlations.

  2. 5 CFR 9701.322 - Setting and adjusting rate ranges.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... MANAGEMENT SYSTEM (DEPARTMENT OF HOMELAND SECURITY-OFFICE OF PERSONNEL MANAGEMENT) DEPARTMENT OF HOMELAND SECURITY HUMAN RESOURCES MANAGEMENT SYSTEM Pay and Pay Administration Setting and Adjusting Rate Ranges... operational reasons, these adjustments will become effective on or about the date of the annual General...

  3. Design of voice coil motor dynamic focusing unit for a laser scanner

    NASA Astrophysics Data System (ADS)

    Lee, Moon G.; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho

    2014-04-01

    Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden-Fletcher-Goldfarb-Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.

  4. The Geoscience Laser Altimetry/Ranging System (GLARS)

    NASA Technical Reports Server (NTRS)

    Cohen, S. C.; Degnan, J. J.; Bufton, J. L.; Garvin, J. B.; Abshire, J. B.

    1986-01-01

    The Geoscience Laser Altimetry Ranging System (GLARS) is a highly precise distance measurement system to be used for making extremely accurate geodetic observations from a space platform. It combines the attributes of a pointable laser ranging system making observations to cube corner retroreflectors placed on the ground with those of a nadir looking laser altimeter making height observations to ground, ice sheet, and oceanic surfaces. In the ranging mode, centimeter-level precise baseline and station coordinate determinations will be made on grids consisting of 100 to 200 targets separated by distances from a few tens of kilometers to about 1000 km. These measurements will be used for studies of seismic zone crustal deformations and tectonic plate motions. Ranging measurements will also be made to a coarser, but globally distributed array of retroreflectors for both precise geodetic and orbit determination applications. In the altimetric mode, relative height determinations will be obtained with approximately decimeter vertical precision and 70 to 100 meter horizontal resolution. The height data will be used to study surface topography and roughness, ice sheet and lava flow thickness, and ocean dynamics. Waveform digitization will provide a measure of the vertical extent of topography within each footprint. The planned Earth Observing System is an attractive candidate platform for GLARS since the GLAR data can be used both for direct analyses and for highly precise orbit determination needed in the reduction of data from other sensors on the multi-instrument platform. (1064, 532, and 355 nm)Nd:YAG laser meets the performance specifications for the system.

  5. Design of voice coil motor dynamic focusing unit for a laser scanner.

    PubMed

    Lee, Moon G; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho

    2014-04-01

    Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden-Fletcher-Goldfarb-Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.

  6. Interferometric system based on swept source-optical coherence tomography scheme applied to the measurement of distances of industrial interest

    NASA Astrophysics Data System (ADS)

    Morel, Eneas N.; Russo, Nélida A.; Torga, Jorge R.; Duchowicz, Ricardo

    2016-01-01

    We used an interferometric technique based on typical optical coherence tomography (OCT) schemes for measuring distances of industrial interest. The system employed as a light source a tunable erbium-doped fiber laser of ˜20-pm bandwidth with a tuning range between 1520 and 1570 nm. It has a sufficiently long coherence length to enable long depth range imaging. A set of fiber Bragg gratings was used as a self-calibration method, which has the advantage of being a passive system that requires no additional electronic devices. The proposed configuration and the coherence length of the laser enlarge the range of maximum distances that can be measured with the common OCT configuration, maintaining a good axial resolution. A measuring range slightly >17 cm was determined. The system performance was evaluated by studying the repeatability and axial resolution of the results when the same optical path difference was measured. Additionally, the thickness of a semitransparent medium was also measured.

  7. A UHF RFID system with on-chip-antenna tag for short range communication

    NASA Astrophysics Data System (ADS)

    Qi, Peng; Chun, Zhang; Xijin, Zhao; Zhihua, Wang

    2015-05-01

    A UHF RF identification system based on the 0.18 μm CMOS process has been developed for short range and harsh size requirement applications, which is composed of a fully integrated tag and a special reader. The whole tag chip with the antenna takes up an area of 0.36 mm2, which is smaller than other reported tags with an on-chip antenna (OCA) using the standard CMOS process. A self-defined protocol is proposed to reduce the power consumption, and minimize the size of the tag. The specialized SOC reader system consists of the RF transceiver, digital baseband, MCU and host interface. Its power consumption is about 500 mW. Measurement results show that the system's reading range is 2 mm with 20 dBm reader output power. With an inductive antenna printed on a paper substrate around the OCA tag, the reading range can be extended from several centimeters to meters, depending on the shape and size of the inductive antenna.

  8. Blade tip clearance measurement of the turbine engines based on a multi-mode fiber coupled laser ranging system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Haotian; Duan, Fajie; Wu, Guoxiu

    2014-11-15

    The blade tip clearance is a parameter of great importance to guarantee the efficiency and safety of the turbine engines. In this article, a laser ranging system designed for blade tip clearance measurement is presented. Multi-mode fiber is utilized for optical transmission to guarantee that enough optical power is received by the sensor probe. The model of the tiny sensor probe is presented. The error brought by the optical path difference of different modes of the fiber is estimated and the length of the fiber is limited to reduce this error. The measurement range in which the optical power receivedmore » by the probe remains essentially unchanged is analyzed. Calibration experiments and dynamic experiments are conducted. The results of the calibration experiments indicate that the resolution of the system is about 0.02 mm and the range of the system is about 9 mm.« less

  9. The impact of anisotropy and interaction range on the self-assembly of Janus ellipsoids

    NASA Astrophysics Data System (ADS)

    Ruth, D. P.; Gunton, J. D.; Rickman, J. M.; Li, Wei

    2014-12-01

    We assess the roles of anisotropy and interaction range on the self-assembly of Janus colloidal particles. In particular, Monte Carlo simulation is employed to investigate the propensity for the formation of aggregates in a spheroidal model of a colloid having a relatively short-ranged interaction that is consistent with experimentally realizable systems. By monitoring the equilibrium distribution of aggregates as a function of temperature and density, we identify a "micelle" transition temperature and discuss its dependence on particle shape. We find that, unlike systems with longer ranged interactions, this system does not form micelles below a transition temperature at low density. Rather, larger clusters comprising 20-40 particles characterize the transition. We then examine the dependence of the second virial coefficient on particle shape and well width to determine how these important system parameters affect aggregation. Finally, we discuss possible strategies suggested by this work to promote self-assembly for the encapsulation of particles.

  10. Tracking and data relay satellite system configuration and tradeoff study. Volume 1: TDRS system summary, part 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A Tracking and Data Relay Satellite System (TDRSS) concept for service of low and medium data rate user spacecraft has been defined. The TDRS system uses two geosynchronous dual spin satellites compatible with Delta 2914 to provide command, tracking, and telemetry service between multiple low earth orbiting users and a centrally located ground station. The low data rate user service capability via each TDRS is as follows: (1) forward link at UHF: voice to one user, commands to 20 users (sequential), range and range rate service, and (2) return link at VHF: voice from one user, data from 20 users (simultaneous), range and range rate return signals. The medium data rate user service via each TDRS is as follows: (1) forward link at S band: voice or command and tracking signals to one user, and (2) return link at S band: voice, data and tracking signals from one user "order wire" for high priority service requests (implemented with an earth coverage antenna).

  11. Homeostatic enhancement of sensory transduction

    PubMed Central

    Milewski, Andrew R.; Ó Maoiléidigh, Dáibhid; Salvi, Joshua D.; Hudspeth, A. J.

    2017-01-01

    Our sense of hearing boasts exquisite sensitivity, precise frequency discrimination, and a broad dynamic range. Experiments and modeling imply, however, that the auditory system achieves this performance for only a narrow range of parameter values. Small changes in these values could compromise hair cells’ ability to detect stimuli. We propose that, rather than exerting tight control over parameters, the auditory system uses a homeostatic mechanism that increases the robustness of its operation to variation in parameter values. To slowly adjust the response to sinusoidal stimulation, the homeostatic mechanism feeds back a rectified version of the hair bundle’s displacement to its adaptation process. When homeostasis is enforced, the range of parameter values for which the sensitivity, tuning sharpness, and dynamic range exceed specified thresholds can increase by more than an order of magnitude. Signatures in the hair cell’s behavior provide a means to determine through experiment whether such a mechanism operates in the auditory system. Robustness of function through homeostasis may be ensured in any system through mechanisms similar to those that we describe here. PMID:28760949

  12. Three-dimensional tracking and imaging laser scanner for space operations

    NASA Astrophysics Data System (ADS)

    Laurin, Denis G.; Beraldin, J. A.; Blais, Francois; Rioux, Marc; Cournoyer, Luc

    1999-05-01

    This paper presents the development of a laser range scanner (LARS) as a three-dimensional sensor for space applications. The scanner is a versatile system capable of doing surface imaging, target ranging and tracking. It is capable of short range (0.5 m to 20 m) and long range (20 m to 10 km) sensing using triangulation and time-of-flight (TOF) methods respectively. At short range (1 m), the resolution is sub-millimeter and drops gradually with distance (2 cm at 10 m). For long range, the TOF provides a constant resolution of plus or minus 3 cm, independent of range. The LARS could complement the existing Canadian Space Vision System (CSVS) for robotic manipulation. As an active vision system, the LARS is immune to sunlight and adverse lighting; this is a major advantage over the CSVS, as outlined in this paper. The LARS could also replace existing radar systems used for rendezvous and docking. There are clear advantages of an optical system over a microwave radar in terms of size, mass, power and precision. Equipped with two high-speed galvanometers, the laser can be steered to address any point in a 30 degree X 30 degree field of view. The scanning can be continuous (raster scan, Lissajous) or direct (random). This gives the scanner the ability to register high-resolution 3D images of range and intensity (up to 4000 X 4000 pixels) and to perform point target tracking as well as object recognition and geometrical tracking. The imaging capability of the scanner using an eye-safe laser is demonstrated. An efficient fiber laser delivers 60 mW of CW or 3 (mu) J pulses at 20 kHz for TOF operation. Implementation of search and track of multiple targets is also demonstrated. For a single target, refresh rates up to 137 Hz is possible. Considerations for space qualification of the scanner are discussed. Typical space operations, such as docking, object attitude tracking, and inspections are described.

  13. OR automation systems.

    PubMed

    2002-12-01

    An operating room (OR) automation system is a combination of hardware and software designed to address efficiency issues in the OR by controling multiple devices via a common interface. Systems range from the relatively basic--allowing control of a few devices within a single OR--to advanced designs that are capable of not only controlling a wide range of devices within the OR but also exchanging information with remote locations.

  14. TOPEX orbit determination using GPS signals plus a sidetone ranging system

    NASA Technical Reports Server (NTRS)

    Bender, P. L.; Larden, D. R.

    1982-01-01

    The GPS orbit determination was studied to see how well the radial coordinate for altimeter satellites such as TOPEX could be found by on board measurements of GPS signals, including the reconstructed carrier phase. The inclusion on altimeter satellites of an additional high accuracy tracking system is recommended. It is suggested that a sidetone ranging system is used in conjunction with TRANET 2 beacons.

  15. The Western Aeronautical Test Range of NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Moore, A. L.

    1984-01-01

    An overview of the Western Aeronautical Test Range (WATR) of NASA Ames Research Center (ARC) is presented in this paper. The three WATR facilities are discussed, and three WATR elements - mission control centerns, communications systems, real-time processing and display systems, and tracking systems -are reviewed. The relationships within the NASA WATR, with respect to the NASA aeronautics program, are also discussed.

  16. Three-dimensional microscope tracking system using the astigmatic lens method and a profile sensor

    NASA Astrophysics Data System (ADS)

    Kibata, Hiroki; Ishii, Katsuhiro

    2018-03-01

    We developed a three-dimensional microscope tracking system using the astigmatic lens method and a profile sensor, which provides three-dimensional position detection over a wide range at the rate of 3.2 kHz. First, we confirmed the range of target detection of the developed system, where the range of target detection was shown to be ± 90 µm in the horizontal plane and ± 9 µm in the vertical plane for a 10× objective lens. Next, we attempted to track a motion-controlled target. The developed system kept the target at the center of the field of view and in focus up to a target speed of 50 µm/s for a 20× objective lens. Finally, we tracked a freely moving target. We successfully demonstrated the tracking of a 10-µm-diameter polystyrene bead suspended in water for 40 min. The target was kept in the range of approximately 4.9 µm around the center of the field of view. In addition, the vertical direction was maintained in the range of ± 0.84 µm, which was sufficiently within the depth of focus.

  17. Demographics and practices of semi-intensive free-range farming systems in Australia with an outdoor stocking density of ≤1500 hens/hectare

    PubMed Central

    Ruhnke, Isabelle; de Koning, Carolyn; Drake, Kelly; Skerman, Alan G.; Hinch, Geoff N.; Glatz, Philip C.

    2017-01-01

    Baseline information on demographics and practices on semi-intensive free-range egg farms with an outdoor stocking density of ≤1500 hens/hectare in Australia is presented. Free-range egg production is changing the structure of the egg industry in Australia and a broad variety and tiers of free-range systems have emerged due to lack of concrete legislative standards on outdoor stocking densities in the past. Information was extracted from a pre-existing online free-range poultry survey dataset, consisting of a total of 79 questions related to nutrition, pasture management, welfare and health, animal housing, environmental impact and economics. Forty-one free-range egg farms, with an outdoor stocking density of ≤1500 hens/hectare, were identified in the dataset from all major Australian states. Two types of semi-intensive free-range housing systems were documented: mobile (modified caravan/trailer) housing (56%), and fixed sheds (44%). Seventy-two percent of respondents reported >75% of the hens in the flock used the outdoor range. All respondents reported ingestion of range components by hens in the form of vegetation, insects, stones and grit. Up to 10% mortality was reported by 40% respondents with predation (34%), cannibalism (29%), heat stress (24%) and grass impaction (19.5%) as major causes. Biosecurity on farms was sub-optimal with 8 of the 10 actions implemented by <50% respondents. Customer demand, consumer sentiment and welfare were the major factors for farmers moving into free-range egg production. This study resulted in identification of current practices and key challenges on semi-intensive free-range egg farms. Applied research and communication of results to farmers is highly recommended to ensure optimum health and welfare of free-range laying hens and sustained egg production. PMID:29065169

  18. Demographics and practices of semi-intensive free-range farming systems in Australia with an outdoor stocking density of ≤1500 hens/hectare.

    PubMed

    Singh, Mini; Ruhnke, Isabelle; de Koning, Carolyn; Drake, Kelly; Skerman, Alan G; Hinch, Geoff N; Glatz, Philip C

    2017-01-01

    Baseline information on demographics and practices on semi-intensive free-range egg farms with an outdoor stocking density of ≤1500 hens/hectare in Australia is presented. Free-range egg production is changing the structure of the egg industry in Australia and a broad variety and tiers of free-range systems have emerged due to lack of concrete legislative standards on outdoor stocking densities in the past. Information was extracted from a pre-existing online free-range poultry survey dataset, consisting of a total of 79 questions related to nutrition, pasture management, welfare and health, animal housing, environmental impact and economics. Forty-one free-range egg farms, with an outdoor stocking density of ≤1500 hens/hectare, were identified in the dataset from all major Australian states. Two types of semi-intensive free-range housing systems were documented: mobile (modified caravan/trailer) housing (56%), and fixed sheds (44%). Seventy-two percent of respondents reported >75% of the hens in the flock used the outdoor range. All respondents reported ingestion of range components by hens in the form of vegetation, insects, stones and grit. Up to 10% mortality was reported by 40% respondents with predation (34%), cannibalism (29%), heat stress (24%) and grass impaction (19.5%) as major causes. Biosecurity on farms was sub-optimal with 8 of the 10 actions implemented by <50% respondents. Customer demand, consumer sentiment and welfare were the major factors for farmers moving into free-range egg production. This study resulted in identification of current practices and key challenges on semi-intensive free-range egg farms. Applied research and communication of results to farmers is highly recommended to ensure optimum health and welfare of free-range laying hens and sustained egg production.

  19. Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators

    NASA Technical Reports Server (NTRS)

    Trolinger, James; Lal, Amit; Jo, Joshua; Kupiec, Stephen

    2012-01-01

    For many aspheric and freeform optical components, existing interferometric solutions require a custom computer-generated hologram (CGH) to characterize the part. The overall objective of this research is to develop hardware and a procedure to produce a combined, dynamic, Hartmann/ Digital Holographic interferometry inspection system for a wide range of advanced optical components, including aspheric and freeform optics. This new instrument would have greater versatility and dynamic range than currently available measurement systems. The method uses a spatial light modulator to pre-condition wavefronts for imaging, interferometry, and data processing to improve the resolution and versatility of an optical inspection instrument. Existing interferometers and Hartmann inspection systems have either too small a dynamic range or insufficient resolution to characterize conveniently unusual optical surfaces like aspherical and freeform optics. For interferometers, a specially produced, computer-generated holographic optical element is needed to transform the wavefront to within the range of the interferometer. A new hybrid wavefront sensor employs newly available spatial light modulators (SLMs) as programmable holographic optical elements (HOEs). The HOE is programmed to enable the same instrument to inspect an optical element in stages, first by a Hartmann measurement, which has a very large dynamic range but less resolution. The first measurement provides the information required to precondition a reference wave that avails the measurement process to the more precise phase shifting interferometry. The SLM preconditions a wavefront before it is used to inspect an optical component. This adds important features to an optical inspection system, enabling not just wavefront conditioning for null testing and dynamic range extension, but also the creation of hybrid measurement procedures. This, for example, allows the combination of dynamic digital holography and Hartmann sensing procedures to cover a virtually unlimited dynamic range with high resolution. Digital holography technology brings all of the power and benefits of digital holographic interferometry to the requirement, while Hartmann-type wavefront sensors bring deflectometry technologies to the solution. The SLM can be used to generate arbitrary wavefronts in one leg of the interferometer, thereby greatly simplifying its use and extending its range. The SLM can also be used to modify the system into a dynamic Shack-Hartmann system, which is useful for optical components with large amounts of slope. By integrating these capabilities into a single instrument, the system will have tremendous flexibility to measure a variety of optical shapes accurately.

  20. SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hui, C; Robertson, D; Alsanea, F

    2015-06-15

    Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. Amore » CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator system provides a reliable and convenient tool for proton range measurement. This project was supported in part by award number CA182450 from the National Cancer Institute.« less

  1. A novel high-resolution chaotic lidar with optical injection to chaotic laser diode

    NASA Astrophysics Data System (ADS)

    Wang, Yun-cai; Wang, An-bang

    2008-03-01

    A novel chaotic lidar with high resolution is proposed and studied theoretically. In chaotic lidar system, the chaotic laser emitted from chaotic laser diode is split into two beams: the probe and the reference light. The ranging is achieved by correlating the reference waveform with the delayed probe waveform backscattered from the target. In chaotic lidar systems presented previously, the chaotic signal source is laser diode with optical feedback or with optical injection by another one. The ranging resolution is limited by the bandwidth of chaotic laser which determined by the configuration of chaotic signal source. We proposed a novel chaotic lidar which ranging resolution is enhanced significantly by external optical injected chaotic laser diode. With the bandwidth-enhanced chaotic laser, the range resolution of the chaotic lidar system with optical injection is roughly two times compared with that of without optical injection. The resolution increases with injection strength increasing in a certain frequency detuning range.

  2. Fourier transform spectrometer for spectral emissivity measurement in the temperature range between 60 and 1500°C

    NASA Astrophysics Data System (ADS)

    Dai, Jingmin; Wang, Xinbei; Yuan, Guibin

    2005-01-01

    A new spectral emissivity measurement system has been developed at Harbin Institute of Technology (HIT) by using a Fourier transform infrared (FTIR) spectrometer. The spectral range between 0.6 and 25 µm was covered by a photovoltaic HgCdTe and a silicon photodiode detector. A SiC heater with a black hole was employed for heating the sample. The temperature of the sample can be controlled in a range between 60 and 1500°C with an error of less than 1°C. The system was calibrated against two high quality reference blackbodies: a low temperature heat-pipe blackbody operated in the temperature range between 60°C and 300°C and a high temperature blackbody with SiC heater operated in the temperature range between 300°C and 1500°C. Several tests were done for this new system. The estimated uncertainty of emissivity measurement is better than 3%.

  3. Ranging Apparatus and Method Implementing Stereo Vision System

    NASA Technical Reports Server (NTRS)

    Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1997-01-01

    A laser-directed ranging system for use in telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a left and right video camera mounted on a camera platform, and a remotely positioned operator. The position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. A laser is provided between the left and right video camera and is directed by the user to point to a target device. The images produced by the left and right video cameras are processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. The horizontal disparity between the two processed images is calculated for use in a stereometric ranging analysis from which range is determined.

  4. CFO compensation method using optical feedback path for coherent optical OFDM system

    NASA Astrophysics Data System (ADS)

    Moon, Sang-Rok; Hwang, In-Ki; Kang, Hun-Sik; Chang, Sun Hyok; Lee, Seung-Woo; Lee, Joon Ki

    2017-07-01

    We investigate feasibility of carrier frequency offset (CFO) compensation method using optical feedback path for coherent optical orthogonal frequency division multiplexing (CO-OFDM) system. Recently proposed CFO compensation algorithms provide wide CFO estimation range in electrical domain. However, their practical compensation range is limited by sampling rate of an analog-to-digital converter (ADC). This limitation has not drawn attention, since the ADC sampling rate was high enough comparing to the data bandwidth and CFO in the wireless OFDM system. For CO-OFDM, the limitation is becoming visible because of increased data bandwidth, laser instability (i.e. large CFO) and insufficient ADC sampling rate owing to high cost. To solve the problem and extend practical CFO compensation range, we propose a CFO compensation method having optical feedback path. By adding simple wavelength control for local oscillator, the practical CFO compensation range can be extended to the sampling frequency range. The feasibility of the proposed method is experimentally investigated.

  5. Single site laparoscopic right hemicolectomy: an oncological feasible option

    PubMed Central

    2010-01-01

    Introduction We present the first 7 cases of single site right hemicolectomy in Asia using the new Single Site Laparoscopy (SSL) access system from Ethicon Endo-surgery. Methods Right hemicolectomy was performed using the new Single Site Laparoscopy (SSL) access system. Patient demographics, operative time, histology and post operative recovery and complications were collected and analysed. Results The median operative time was 90 mins (range 60 - 150 mins) and a median wound size of 2.5 cm (range 2 to 4.5 cm). The median number of lymph nodes harvested was 24 (range 20 to 34 lymph nodes). The median length of proximal margin was 70 mm (range 30 to 145 mm) and that of distal margin was 50 mm (35 to 120 mm). All patients had a median hospital stay of 7 days (range 5 to 11) and there were no significant perioperative complications except for 1 patient who had a minor myocardial event. Conclusion Right hemicolectomy using SSL access system is feasible and safe for oncologic surgery. PMID:20825658

  6. Spread of Correlations in Long-Range Interacting Quantum Systems

    NASA Astrophysics Data System (ADS)

    Hauke, P.; Tagliacozzo, L.

    2013-11-01

    The nonequilibrium response of a quantum many-body system defines its fundamental transport properties and how initially localized quantum information spreads. However, for long-range-interacting quantum systems little is known. We address this issue by analyzing a local quantum quench in the long-range Ising model in a transverse field, where interactions decay as a variable power law with distance ∝r-α, α>0. Using complementary numerical and analytical techniques, we identify three dynamical regimes: short-range-like with an emerging light cone for α>2, weakly long range for 1<α<2 without a clear light cone but with a finite propagation speed of almost all excitations, and fully nonlocal for α<1 with instantaneous transmission of correlations. This last regime breaks generalized Lieb-Robinson bounds and thus locality. Numerical calculation of the entanglement spectrum demonstrates that the usual picture of propagating quasiparticles remains valid, allowing an intuitive interpretation of our findings via divergences of quasiparticle velocities. Our results may be tested in state-of-the-art trapped-ion experiments.

  7. Discrete-time model reduction in limited frequency ranges

    NASA Technical Reports Server (NTRS)

    Horta, Lucas G.; Juang, Jer-Nan; Longman, Richard W.

    1991-01-01

    A mathematical formulation for model reduction of discrete time systems such that the reduced order model represents the system in a particular frequency range is discussed. The algorithm transforms the full order system into balanced coordinates using frequency weighted discrete controllability and observability grammians. In this form a criterion is derived to guide truncation of states based on their contribution to the frequency range of interest. Minimization of the criterion is accomplished without need for numerical optimization. Balancing requires the computation of discrete frequency weighted grammians. Close form solutions for the computation of frequency weighted grammians are developed. Numerical examples are discussed to demonstrate the algorithm.

  8. Microwave time delays for the dual L-C-band feed system

    NASA Technical Reports Server (NTRS)

    Chen, J.

    1989-01-01

    A new dual-frequency feed system at Goldstone is designed to receive the Phobos spacecraft signal at L-band (1668 + or - 40 MHz) and transmit to the spacecraft at C-band (5008.75 + or - 5.00 MHz) simultaneously. Hence, calculations of the time delay from the C-band range calibration coupler to the phase center of the L-C dual feed and back to the L-band range calibration coupler are required to correct the range measurements. Time delays of the elements in the dual-frequency feed system are obtained mostly from computer calculations and partly from experimental measurements. The method used and results obtained are described.

  9. Microbial diversity on commercial eggs as affected by the production system. A first approach using PGM.

    PubMed

    Neira, Carmen; Laca, Amanda; Laca, Adriana; Díaz, Mario

    2017-12-04

    A novel DNA-based technique (PGM) has been employed for first time to analyse commercial eggs with the advantage of allowing an exhaustive identification of the microbiota present. Eggs from two different production systems, i.e. a free range system and a cage system, were analysed. Twenty-one and twenty-two phyla were identified on the surface of cage system and free range system eggs, respectively. In both cases, Firmicutes was the dominant phylum (representing around 50% of total phyla), being found families frequently reported to be present in the intestinal microbiota of chickens or hens, such as Clostridiaceae, Ruminococcaceae and Lachnospiraceae. Additionally, other phyla and families not previously described in association with eggshells could also be identified in this work. Most of the potential pathogenic genera associated with eggs (Salmonella, Clostridium, Helicobacter, Pseudomonas and Staphylococcus) showed higher incidence in eggs coming from cage systems than in eggs coming from free range systems, although the abundance of these genera were very low in both cases (<5% of total bacteria). Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Evaluation of the performance of the OneTouch Select Plus blood glucose test system against ISO 15197:2013.

    PubMed

    Setford, Steven; Smith, Antony; McColl, David; Grady, Mike; Koria, Krisna; Cameron, Hilary

    2015-01-01

    Assess laboratory and in-clinic performance of the OneTouch Select(®) Plus test system against ISO 15197:2013 standard for measurement of blood glucose. System performance assessed in laboratory against key patient, environmental and pharmacologic factors. User performance was assessed in clinic by system-naïve lay-users. Healthcare professionals assessed system accuracy on diabetes subjects in clinic. The system demonstrated high levels of performance, meeting ISO 15197:2013 requirements in laboratory testing (precision, linearity, hematocrit, temperature, humidity and altitude). System performance was tested against 28 interferents, with an adverse interfering effect only being recorded for pralidoxime iodide. Clinic user performance results fulfilled ISO 15197:2013 accuracy criteria. Subjects agreed that the color range indicator clearly showed if they were low, in-range or high and helped them better understand glucose results. The system evaluated is accurate and meets all ISO 15197:2013 requirements as per the tests described. The color range indicator helped subjects understand glucose results and supports patients in following healthcare professional recommendations on glucose targets.

  11. An airborne low SWaP-C UAS sense and avoid system

    NASA Astrophysics Data System (ADS)

    Wang, Zhonghai; Lin, Xingping; Xiang, Xingyu; Blasch, Erik; Pham, Khanh; Chen, Genshe; Shen, Dan; Jia, Bin; Wang, Gang

    2016-05-01

    This paper presents a low size, weight and power - cost (SWaP-C) airborne sense and avoid (ABSAA) system, which is based on a linear frequency modulated continuous wave (LFMCW) radar and can be mounted on small unmanned aircraft system (UAS). The system satisfies the constraint of the available sources on group 2/3 UAS. To obtain the desired sense and avoid range, a narrow band frequency (or range) scanning technique is applied for reducing the receiver's noise floor to improve its sensitivity, and a digital signal integration with fast Fourier transform (FFT) is applied to enhance the signal to noise ratio (SNR). The gate length and chirp rate are intelligently adapted to not only accommodate different object distances, speeds and approaching angle conditions, but also optimize the detection speed, resolution and coverage range. To minimize the radar blind zone, a higher chirp rate and a narrowband intermediate frequency (IF) filter are applied at the near region with a single antenna signal for target detection. The offset IF frequency between transmitter (TX) and receiver (RX) is designed to mitigate the TX leakage to the receiver, especially at close distances. Adaptive antenna gain and beam-width are utilized for searching at far distance and fast 360 degree middle range. For speeding up the system update rate, lower chirp rates and wider IF and baseband filters are applied for obtaining larger range scanning step length out of the near region. To make the system working with a low power transmitter (TX), multiple-antenna beamforming, digital signal integration with FFT, and a much narrower receiver (RX) bandwidth are applied at the far region. The ABSAA system working range is 2 miles with a 1W transmitter and single antenna signal detection, and it is 5 miles when a 5W transmitter and 4-antenna beamforming (BF) are applied.

  12. Development of a precision, wide-dynamic-range actuator for use in active optical systems

    NASA Technical Reports Server (NTRS)

    Lorell, K. R.; Aubrun, J-N.; Zacharie, D. F.; Perez, E. O.

    1989-01-01

    The design, operation, and performance of a wide-dynamic-range optical-quality actuator are discussed. The actuator uses a closed-loop control system to maintain accurate positioning and has an rms noise performance of 20 nm. A unique force offloading mechanism allows the actuator coil to dissipate less than 3 mW under quiescent conditions. The operation of an experimental segmented optical system that uses 18 of the actuators is examined to show how they are integrated into an actual system.

  13. System and method for online inspection of turbines using an optical tube with broadspectrum mirrors

    DOEpatents

    Baleine, Erwan

    2015-12-22

    An optical inspection system for nondestructive internal visual inspection and non-contact infra-red (IR) temperature monitoring of an online, operating power generation turbine. The optical inspection system includes an optical tube having a viewing port, at least one reflective mirror or a mirror array having a reflectivity spectral range from 550 nm to 20 .mu.m, and capable of continuous operation at temperatures greater than 932 degrees Fahrenheit (500 degrees Celsius), and a transparent window with high transmission within the same spectral range mounted distal the viewing port. The same optical mirror array may be used to measure selectively surface temperature of metal turbine blades in the near IR range (approximately 1 .mu.m wavelength) and of thermal barrier coated turbine blades in the long IR range (approximately 10 .mu.m wavelength).

  14. MT's algorithm: A new algorithm to search for the optimum set of modulation indices for simultaneous range, command, and telemetry

    NASA Technical Reports Server (NTRS)

    Nguyen, Tien Manh

    1989-01-01

    MT's algorithm was developed as an aid in the design of space telecommunications systems when utilized with simultaneous range/command/telemetry operations. This algorithm provides selection of modulation indices for: (1) suppression of undesired signals to achieve desired link performance margins and/or to allow for a specified performance degradation in the data channel (command/telemetry) due to the presence of undesired signals (interferers); and (2) optimum power division between the carrier, the range, and the data channel. A software program using this algorithm was developed for use with MathCAD software. This software program, called the MT program, provides the computation of optimum modulation indices for all possible cases that are recommended by the Consultative Committee on Space Data System (CCSDS) (with emphasis on the squarewave, NASA/JPL ranging system).

  15. A Wireless Local Area Network Command and Control System for Explosive Ordnance Disposal Incident Response

    DTIC Science & Technology

    2001-09-01

    43 4. GPS ......................................................................................................44 E. POWER SUPPLY HARDWARE...44 Figure 5.6 Earthmate GPS Receiver ........................................................................................45...and 5Watts at 25 Ft Effective Range Minimum range of wireless link is 5 miles. Positional awareness System requires GPS input to determine

  16. An ultrasonic pseudorandom signal-correlation system

    NASA Astrophysics Data System (ADS)

    Elias, C. M.

    1980-01-01

    A working ultrasonic pseudorandom signal-correlation system is described which, unlike ultrasonic random signal-correlation systems, does not require an acoustic delay line. Elimination of the delay line allows faster data acquisition and better range resolution. The system uses two identical shift-register type generators to produce pseudonoise bursts which are subsequences of a 65 535-bit complementary m-sequence. One generator produces the transmitted bursts while the other generates identical reference bursts which start at a variable correlation delay time after the transmitted bursts. The reference bursts are cross-correlated with the received echoes to obtain the approximate impulse response of the transducer/specimen system under test. Range sidelobes are reduced by transmitting and correlating many bursts at a given correlation delay before incrementing the delay. Signal-to-sidelobe ratios of greater than 47 dB have been obtained using this method. Limitations of the system due to sampling constraints and the pseudonoise power spectrum are discussed, and the system design and implementation are outlined. Results of experimental characterization of the system show that the pseudorandom signal-correlation system has approximately the same range resolution as a conventional pulse-echo system but can yield a significant increase in signal-to-noise ratio (SNR).

  17. Radar Performance Improvement. Angle Tracking Modification to Fire Control Radar System for Space Shuttle Rendezvous

    NASA Technical Reports Server (NTRS)

    Little, G. R.

    1976-01-01

    The AN/APQ-153 fire control radar modified to provide angle tracking was evaluated for improved performance. The frequency agile modifications are discussed along with the range-rate improvement modifications, and the radar to computer interface. A parametric design and comparison of noncoherent and coherent radar systems are presented. It is shown that the shuttle rendezvous range and range-rate requirements can be made by a Ku-Band noncoherent pulse radar.

  18. An investigation of pre-launch and in-flight STS range safety radio signal degradation and dropout

    NASA Technical Reports Server (NTRS)

    Mcdonald, Malcolm W.

    1991-01-01

    The range safety system (RSS) transmitters operate at a frequency of 416.500 MHz. The transmitting antennas transmit left circularly polarized waves, and the shuttle range safety system (SRSS) receiving antennas onboard the shuttle vehicle receive left circular polarization. Preliminary explanations are proposed for many of the observed fluctuations in signal levels. It is recommended that experiments and further investigation be performed to test the validity of certain of these explanations.

  19. The reliability of nonlinear least-squares algorithm for data analysis of neural response activity during sinusoidal rotational stimulation in semicircular canal neurons.

    PubMed

    Ren, Pengyu; Li, Bowen; Dong, Shiyao; Chen, Lin; Zhang, Yuelin

    2018-01-01

    Although many mathematical methods were used to analyze the neural activity under sinusoidal stimulation within linear response range in vestibular system, the reliabilities of these methods are still not reported, especially in nonlinear response range. Here we chose nonlinear least-squares algorithm (NLSA) with sinusoidal model to analyze the neural response of semicircular canal neurons (SCNs) during sinusoidal rotational stimulation (SRS) over a nonlinear response range. Our aim was to acquire a reliable mathematical method for data analysis under SRS in vestibular system. Our data indicated that the reliability of this method in an entire SCNs population was quite satisfactory. However, the reliability was strongly negatively depended on the neural discharge regularity. In addition, stimulation parameters were the vital impact factors influencing the reliability. The frequency had a significant negative effect but the amplitude had a conspicuous positive effect on the reliability. Thus, NLSA with sinusoidal model resulted a reliable mathematical tool for data analysis of neural response activity under SRS in vestibular system and more suitable for those under the stimulation with low frequency but high amplitude, suggesting that this method can be used in nonlinear response range. This method broke out of the restriction of neural activity analysis under nonlinear response range and provided a solid foundation for future study in nonlinear response range in vestibular system.

  20. The reliability of nonlinear least-squares algorithm for data analysis of neural response activity during sinusoidal rotational stimulation in semicircular canal neurons

    PubMed Central

    Li, Bowen; Dong, Shiyao; Chen, Lin; Zhang, Yuelin

    2018-01-01

    Although many mathematical methods were used to analyze the neural activity under sinusoidal stimulation within linear response range in vestibular system, the reliabilities of these methods are still not reported, especially in nonlinear response range. Here we chose nonlinear least-squares algorithm (NLSA) with sinusoidal model to analyze the neural response of semicircular canal neurons (SCNs) during sinusoidal rotational stimulation (SRS) over a nonlinear response range. Our aim was to acquire a reliable mathematical method for data analysis under SRS in vestibular system. Our data indicated that the reliability of this method in an entire SCNs population was quite satisfactory. However, the reliability was strongly negatively depended on the neural discharge regularity. In addition, stimulation parameters were the vital impact factors influencing the reliability. The frequency had a significant negative effect but the amplitude had a conspicuous positive effect on the reliability. Thus, NLSA with sinusoidal model resulted a reliable mathematical tool for data analysis of neural response activity under SRS in vestibular system and more suitable for those under the stimulation with low frequency but high amplitude, suggesting that this method can be used in nonlinear response range. This method broke out of the restriction of neural activity analysis under nonlinear response range and provided a solid foundation for future study in nonlinear response range in vestibular system. PMID:29304173

  1. Effect of short range hydrodynamic on bimodal colloidal gel systems

    NASA Astrophysics Data System (ADS)

    Boromand, Arman; Jamali, Safa; Maia, Joao

    2015-03-01

    Colloidal Gels and disordered arrested systems has been studied extensively during the past decades. Although, they have found their place in multiple industries such as cosmetic, food and so on, their physical principals are still far beyond being understood. The interplay between different types of interactions from quantum scale, Van der Waals interaction, to short range interactions, depletion interaction, and long range interactions such as electrostatic double layer makes this systems challenging from simulation point of view. Many authors have implemented different simulation techniques such as molecular dynamics (MD) and Brownian dynamics (BD) to capture better picture during phase separation of colloidal system with short range attractive force. However, BD is not capable to include multi-body hydrodynamic interaction and MD is limited by the computational resources and is limited to short time and length scales. In this presentation we used Core-modified dissipative particle dynamics (CM-DPD) with modified depletion potential, as a coarse-grain model, to address the gel formation process in short ranged-attractive colloidal suspensions. Due to the possibility to include and separate short and long ranged-hydrodynamic forces in this method we studied the effect of each of those forces on the final morphology and report one of the controversial question in this field on the effect of hydrodynamics on the cluster formation process on bimodal, soft-hard colloidal mixtures.

  2. Ultra High Mass Range Mass Spectrometer System

    DOEpatents

    Reilly, Peter T. A. [Knoxville, TN

    2005-12-06

    Applicant's present invention comprises mass spectrometer systems that operate in a mass range from 1 to 10.sup.16 DA. The mass spectrometer system comprising an inlet system comprising an aerodynamic lens system, a reverse jet being a gas flux generated in an annulus moving in a reverse direction and a multipole ion guide; a digital ion trap; and a thermal vaporization/ionization detector system. Applicant's present invention further comprises a quadrupole mass spectrometer system comprising an inlet system having a quadrupole mass filter and a thermal vaporization/ionization detector system. Applicant's present invention further comprises an inlet system for use with a mass spectrometer system, a method for slowing energetic particles using an inlet system. Applicant's present invention also comprises a detector device and a method for detecting high mass charged particles.

  3. Short-Time Glassy Dynamics in Viscous Protein Solutions with Competing Interactions

    DOE PAGES

    Godfrin, P. Douglas; Hudson, Steven; Hong, Kunlun; ...

    2015-11-24

    Although there have been numerous investigations of the glass transition for colloidal dispersions with only a short-ranged attraction, less is understood for systems interacting with a long-ranged repulsion in addition to this attraction, which is ubiquitous in aqueous protein solutions at low ionic strength. Highly puri ed concentrated lysozyme solutions are used as a model system and investigated over a large range of protein concentrations at very low ionic strength. Newtonian liquid behavior is observed at all concentrations, even up to 480 mg/mL, where the zero shear viscosity increases by more than three orders of magnitude with increasing concentration. Remarkably,more » despite this macroscopic liquid-like behavior, the measurements of the dynamics in the short-time limit shows features typical of glassy colloidal systems. Investigation of the inter-protein structure indicates that the reduced short-time mobility of the protein is caused by localized regions of high density within a heterogeneous density distribution. This structural heterogeneity occurs on intermediate range length scale, driven by the competing potential features, and is distinct from commonly studied colloidal gel systems in which a heterogeneous density distribution tends to extend to the whole system. The presence of long-ranged repulsion also allows for more mobility over large length and long time scales resulting in the macroscopic relaxation of the structure. The experimental results provide evidence for the need to explicitly include intermediate range order in theories for the macroscopic properties of protein solutions interacting via competing potential features.« less

  4. A nonrecursive 'Order N' preconditioned conjugate gradient/range space formulation of MDOF dynamics

    NASA Technical Reports Server (NTRS)

    Kurdila, A. J.; Menon, R.; Sunkel, John

    1991-01-01

    This paper addresses the requirements of present-day mechanical system simulations of algorithms that induce parallelism on a fine scale and of transient simulation methods which must be automatically load balancing for a wide collection of system topologies and hardware configurations. To this end, a combination range space/preconditioned conjugage gradient formulation of multidegree-of-freedon dynamics is developed, which, by employing regular ordering of the system connectivity graph, makes it possible to derive an extremely efficient preconditioner from the range space metric (as opposed to the system coefficient matrix). Because of the effectiveness of the preconditioner, the method can achieve performance rates that depend linearly on the number of substructures. The method, termed 'Order N' does not require the assembly of system mass or stiffness matrices, and is therefore amenable to implementation on work stations. Using this method, a 13-substructure model of the Space Station was constructed.

  5. International Ultraviolet Explorer observations of the peculiar variable spectrum of the eclipsing binary R Arae

    NASA Technical Reports Server (NTRS)

    Mccluskey, G. E.; Kondo, Y.

    1983-01-01

    The eclipsing binary system R Arae = HD 149730 is a relatively bright southern system with an orbital period of about 4.4 days. It is a single-lined spectroscopic binary. The spectral class of the primary component is B9 Vp. The system was included in a study of mass flow and evolution in close binary systems using the International Ultraviolet Explorer satellite (IUE). Four spectra in the wavelength range from 1150 to 1900 A were obtained with the far-ultraviolet SWP camera, and six spectra in the range from 1900 to 3200 range were obtained with the mid-ultraviolet LWR camera. The close binary R Arae exhibits very unusual ultraviolet spectra. It appears that no other close binary system, observed with any of the orbiting satellites, shows outside-eclipse ultraviolet continuum flux variations of this nature.

  6. Cryocooled terahertz photoconductive detector system with background-limited performance in 1.5–4 THz frequency range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aoki, Makoto; Hiromoto, Norihisa, E-mail: dnhirom@ipc.shizuoka.ac

    2015-10-15

    We describe a 4-K-cryocooled dual-band terahertz (THz) photoconductive detector system with background-limited performance. The detector system comprises two THz photoconductive detectors covering a response in a wide frequency range from 1.5 to 4 THz, low noise amplifiers, optical low-pass filters to eliminate input radiation of higher frequencies, and a mechanical 4 K Gifford-McMahon refrigerator that provides practical and convenient operation without a liquid He container. The electrical and optical performances of the THz detector system were evaluated at a detector temperature of 4 K under 300 K background radiation. We proved that the detector system can achieve background-limited noise-equivalent-power onmore » the order of 10{sup −14} W/Hz{sup 1/2} in the frequency range from 1.5 to 4 THz even if the vibration noise of the mechanical refrigerator is present.« less

  7. Megawatt level electric propulsion perspectives

    NASA Technical Reports Server (NTRS)

    Jahn, Robert G.; Kelly, Arnold J.

    1987-01-01

    For long range space missions, deliverable payload fraction is an inverse exponential function of the propellant exhaust velocity or specific impulse of the propulsion system. The exhaust velocity of chemical systems are limited by their combustion chemistry and heat transfer to a few km/s. Nuclear rockets may achieve double this range, but are still heat transfer limited and ponderous to develop. Various electric propulsion systems can achieve exhaust velocities in the 10 km/s range, at considerably lower thrust densities, but require an external electrical power source. A general overview is provided of the currently available electric propulsion systems from the perspective of their characteristics as a terminal load for space nuclear systems. A summary of the available electric propulsion options is shown and generally characterized in the power vs. exhaust velocity plot. There are 3 general classes of electric thruster devices: neutral gas heaters, plasma devices, and space charge limited electrostatic or ion thrusters.

  8. Tradeoff between magnet volume and tuning capacitor in a free piston Stirling engine power generation system

    NASA Astrophysics Data System (ADS)

    Fu, Z. X.; Nasar, S. A.; Rosswurm, Mark

    This paper presents the criteria in selecting the size of the tuning capacitor, and the cost tradeoff between magnet volume and tuning capacitor in a free piston Stirling engine power generation system. The permissible range of capacitor size corresponding to different magnet volume, in order to prevent magnet demagnetization and stabilize the operation of the system, is determined. Within the permissible range suitable capacitor size may be selected to compensate the inductive load of the system to improve the overall power factor. If the capacitor size is not in the permissible range, there would exist a danger of losing magnet strength, or unstable operation of the engine that would destroy the engine due to unbounded amplitude of piston oscillations. The theory developed is then applied to a practical system, and the cost tradeoff between magnet volume and capacitor is studied.

  9. Cryocooled terahertz photoconductive detector system with background-limited performance in 1.5-4 THz frequency range.

    PubMed

    Aoki, Makoto; Hiromoto, Norihisa

    2015-10-01

    We describe a 4-K-cryocooled dual-band terahertz (THz) photoconductive detector system with background-limited performance. The detector system comprises two THz photoconductive detectors covering a response in a wide frequency range from 1.5 to 4 THz, low noise amplifiers, optical low-pass filters to eliminate input radiation of higher frequencies, and a mechanical 4 K Gifford-McMahon refrigerator that provides practical and convenient operation without a liquid He container. The electrical and optical performances of the THz detector system were evaluated at a detector temperature of 4 K under 300 K background radiation. We proved that the detector system can achieve background-limited noise-equivalent-power on the order of 10(-14) W/Hz(1/2) in the frequency range from 1.5 to 4 THz even if the vibration noise of the mechanical refrigerator is present.

  10. Transparent, immiscible, surrogate liquids with matchable refractive indexes: Increased range of density and viscosity ratios

    NASA Astrophysics Data System (ADS)

    Cadillon, Jérémy; Saksena, Rajat; Pearlstein, Arne J.

    2016-12-01

    By replacing the "heavy" silicone oil used in the oil phase of Saksena, Christensen, and Pearlstein ["Surrogate immiscible liquid pairs with refractive indexes matchable over a wide range of density and viscosity ratios," Phys. Fluids 27, 087103 (2015)] by one with a twentyfold higher viscosity, and replacing the "light" silicone oil in that work by one with a viscosity fivefold lower and a density about 10% lower, we have greatly extended the range of viscosity ratio accessible by index-matching the adjustable-composition oil phase to an adjustable-composition 1,2-propanediol + CsBr + H2O aqueous phase and have also extended the range of accessible density ratios. The new system of index-matchable surrogate immiscible liquids is capable of achieving the density and viscosity ratios for liquid/liquid systems consisting of water with the entire range of light or medium crude oils over the temperature range from 40 °F (4.44 °C) to 200 °F (93.3 °C) and can access the density and viscosity ratios for water with some heavy crude oils over part of the same temperature range. It also provides a room-temperature, atmospheric-pressure surrogate for the liquid CO2 + H2O system at 0 °C over almost all of the pressure range of interest in sub-seabed CO2 sequestration.

  11. Influence of Time-Pickoff Circuit Parameters on LiDAR Range Precision

    PubMed Central

    Wang, Hongming; Yang, Bingwei; Huyan, Jiayue; Xu, Lijun

    2017-01-01

    A pulsed time-of-flight (TOF) measurement-based Light Detection and Ranging (LiDAR) system is more effective for medium-long range distances. As a key ranging unit, a time-pickoff circuit based on automatic gain control (AGC) and constant fraction discriminator (CFD) is designed to reduce the walk error and the timing jitter for obtaining the accurate time interval. Compared with Cramer–Rao lower bound (CRLB) and the estimation of the timing jitter, four parameters-based Monte Carlo simulations are established to show how the range precision is influenced by the parameters, including pulse amplitude, pulse width, attenuation fraction and delay time of the CFD. Experiments were carried out to verify the relationship between the range precision and three of the parameters, exclusing pulse width. It can be concluded that two parameters of the ranging circuit (attenuation fraction and delay time) were selected according to the ranging performance of the minimum pulse amplitude. The attenuation fraction should be selected in the range from 0.2 to 0.6 to achieve high range precision. The selection criterion of the time-pickoff circuit parameters is helpful for the ranging circuit design of TOF LiDAR system. PMID:29039772

  12. Advanced digital SAR processing study

    NASA Technical Reports Server (NTRS)

    Martinson, L. W.; Gaffney, B. P.; Liu, B.; Perry, R. P.; Ruvin, A.

    1982-01-01

    A highly programmable, land based, real time synthetic aperture radar (SAR) processor requiring a processed pixel rate of 2.75 MHz or more in a four look system was designed. Variations in range and azimuth compression, number of looks, range swath, range migration and SR mode were specified. Alternative range and azimuth processing algorithms were examined in conjunction with projected integrated circuit, digital architecture, and software technologies. The advaced digital SAR processor (ADSP) employs an FFT convolver algorithm for both range and azimuth processing in a parallel architecture configuration. Algorithm performace comparisons, design system design, implementation tradeoffs and the results of a supporting survey of integrated circuit and digital architecture technologies are reported. Cost tradeoffs and projections with alternate implementation plans are presented.

  13. Unifying latitudinal gradients in range size and richness across marine and terrestrial systems

    PubMed Central

    Tomašových, Adam; Kennedy, Jonathan D.; Betzner, Tristan J.; Kuehnle, Nicole Bitler; Edie, Stewart; Kim, Sora; Supriya, K.; White, Alexander E.; Rahbek, Carsten; Huang, Shan; Price, Trevor D.; Jablonski, David

    2016-01-01

    Many marine and terrestrial clades show similar latitudinal gradients in species richness, but opposite gradients in range size—on land, ranges are the smallest in the tropics, whereas in the sea, ranges are the largest in the tropics. Therefore, richness gradients in marine and terrestrial systems do not arise from a shared latitudinal arrangement of species range sizes. Comparing terrestrial birds and marine bivalves, we find that gradients in range size are concordant at the level of genera. Here, both groups show a nested pattern in which narrow-ranging genera are confined to the tropics and broad-ranging genera extend across much of the gradient. We find that (i) genus range size and its variation with latitude is closely associated with per-genus species richness and (ii) broad-ranging genera contain more species both within and outside of the tropics when compared with tropical- or temperate-only genera. Within-genus species diversification thus promotes genus expansion to novel latitudes. Despite underlying differences in the species range-size gradients, species-rich genera are more likely to produce a descendant that extends its range relative to the ancestor's range. These results unify species richness gradients with those of genera, implying that birds and bivalves share similar latitudinal dynamics in net species diversification. PMID:27147094

  14. Power allocation and range performance considerations for a dual-frequency EBPSK/MPPSK system

    NASA Astrophysics Data System (ADS)

    Yao, Yu; Wu, Lenan; Zhao, Junhui

    2017-12-01

    Extended binary phase shift keying/M-ary position phase shift keying (EBPSK/MPPSK)-MODEM provides radar and communication functions on a single hardware platform with a single waveform. However, its range estimation accuracy is worse than continuous-wave (CW) radar because of the imbalance of power in two carrier frequencies. In this article, the power allocation method for dual-frequency EBPSK/MPPSK modulated systems is presented. The power of two signal transmitters is adequately allocated to ensure that the power in two carrier frequencies is equal. The power allocation ratios for two types of modulation systems are obtained. Moreover, considerations regarding the range of operation of the dual-frequency system are analysed. In addition to theoretical considerations, computer simulations are provided to illustrate the performance.

  15. Selective encapsulation by Janus particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Wei, E-mail: wel208@mrl.ucsb.edu; Ruth, Donovan; Gunton, James D.

    2015-06-28

    We employ Monte Carlo simulation to examine encapsulation in a system comprising Janus oblate spheroids and isotropic spheres. More specifically, the impact of variations in temperature, particle size, inter-particle interaction range, and strength is examined for a system in which the spheroids act as the encapsulating agents and the spheres as the encapsulated guests. In this picture, particle interactions are described by a quasi-square-well patch model. This study highlights the environmental adaptation and selectivity of the encapsulation system to changes in temperature and guest particle size, respectively. Moreover, we identify an important range in parameter space where encapsulation is favored,more » as summarized by an encapsulation map. Finally, we discuss the generalization of our results to systems having a wide range of particle geometries.« less

  16. Development of Acceleration Sensor and Acceleration Evaluation System for Super-Low-Range Frequencies

    NASA Astrophysics Data System (ADS)

    Asano, Shogo; Matsumoto, Hideki

    2001-05-01

    This paper describes the development process for acceleration sensors used on automobiles and an acceleration evaluation system designed specifically for acceleration at super-low-range frequencies. The features of the newly developed sensor are as follows. 1) Original piezo-bimorph design based on a disc-center-fixed structure achieves pyroeffect cancelling and stabilization of sensor characteristics and enables the detection of the acceleration of 0.0009 G at the super-low-range-frequency of 0.03 Hz. 2) The addition of a self-diagnostic function utilizing the characteristics of piezoceramics enables constant monitoring of sensor failure. The frequency range of acceleration for accurate vehicle motion control is considered to be from DC to about 50 Hz. However, the measurement of acceleration in the super-low-range frequency near DC has been difficult because of mechanical and electrical noise interruption. This has delayed the development of the acceleration sensor for automotive use. We have succeeded in the development of an acceleration evaluation system for super-low-range frequencies from 0.015 Hz to 2 Hz with detection of the acceleration range from 0.0002 G (0.2 gal) to 1 G, as well as the development of a piezoelectric-type acceleration sensor for automotive use.

  17. The 30/20 GHz mixed user architecture development study

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A mixed-user system is described which provides cost-effective communications services to a wide range of user terminal classes, ranging from one or two voice channel support in a direct-to-user mode, to multiple 500 mbps trunking channel support. Advanced satellite capabilities are utilized to minimize the cost of small terminals. In a system with thousands of small terminals, this approach results in minimum system cost.

  18. Manufacturing Work Measurement System Evaluation. Reference Guide

    DTIC Science & Technology

    1987-04-01

    discussions with users of the MTM-MEK predetermined time system. The coranents listed below are based on these discussions and, while a broad range...discussions with users of the MTM-V predeterroined time system. The coranents listed below are based on these discussions and, while a broad range of...industries were sampled, coranents should not be considered universal and therefore may not be applicable to all manufacturing environments: 0 Easy to

  19. A broad-host range dual-fluorescence reporter system for gene expression analysis in Gram-negative bacteria.

    PubMed

    Hennessy, Rosanna C; Christiansen, Line; Olsson, Stefan; Stougaard, Peter

    2018-01-01

    Fluorescence-based reporter systems are valuable tools for studying gene expression dynamics in living cells. Here we describe a dual-fluorescence reporter system carrying the red fluorescent marker mCherry and the blue fluorescent protein EBFP2 enabling the simultaneous analysis of two promoters in broad-host range autofluorescent Gram-negative bacteria. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Systems Engineering Approach for Conceptual Design of Frigate

    DTIC Science & Technology

    2015-09-01

    ejection area. Topside designers should also take note of the gun maintenance required area (e.g., barrel swabbing area), which requires significant...Figure 9. Range-to-Target Plot (BlueIntercept Missile vs. RedFire) ........................34 Figure 10. Range-to-Target Plot (Main Gun System vs...and the secondary anti-air weapon will be the main gun system. The frigates shall also be equipped with an area terminal type defense (ATTD

  1. Development of biostereometric experiments. [stereometric camera system

    NASA Technical Reports Server (NTRS)

    Herron, R. E.

    1978-01-01

    The stereometric camera was designed for close-range techniques in biostereometrics. The camera focusing distance of 360 mm to infinity covers a broad field of close-range photogrammetry. The design provides for a separate unit for the lens system and interchangeable backs on the camera for the use of single frame film exposure, roll-type film cassettes, or glass plates. The system incorporates the use of a surface contrast optical projector.

  2. Dynamic alignment, tolerances, and metrology fundamentals at the nano and micro scales

    NASA Astrophysics Data System (ADS)

    Silberman, Donn M.

    2015-09-01

    Although the terms "micropositioning" and "nanopositioning" refer to different classes of positioning systems, "nanopositioning" is often used mistakenly to describe micropositioning systems. Micropositioning systems are typically motor-driven stages with travel ranges of a few millimeters up to a few hundred millimeters. Because the guiding systems in such stages — usually bearings of some kind — generate frictional forces, their resolution and repeatability are typically limited to 0.1 μm. The guiding system working principle also adds errors that are typically in the micrometer range. Nanopositioning systems are typically based on frictionless drives and guiding systems such as piezo actuators and flexures. These systems can achieve resolutions and guiding accuracies down to the sub-nanometer level. Both of these classes of precision positioning and motion systems are used extensively in precision optical and photonic systems to achieve desired performance specifications of instruments and experimental research projects. Currently, many precision positioning and motion systems have been design and implemented to cross over from the micro to the nano ranges with excellent results. This paper will describe some of the fundamental performance parameters and tolerances typical of these systems, some of the metrology used to confirm specifications and a few high end applications of general interest.

  3. Single-frequency 3D synthetic aperture imaging with dynamic metasurface antennas.

    PubMed

    Boyarsky, Michael; Sleasman, Timothy; Pulido-Mancera, Laura; Diebold, Aaron V; Imani, Mohammadreza F; Smith, David R

    2018-05-20

    Through aperture synthesis, an electrically small antenna can be used to form a high-resolution imaging system capable of reconstructing three-dimensional (3D) scenes. However, the large spectral bandwidth typically required in synthetic aperture radar systems to resolve objects in range often requires costly and complex RF components. We present here an alternative approach based on a hybrid imaging system that combines a dynamically reconfigurable aperture with synthetic aperture techniques, demonstrating the capability to resolve objects in three dimensions (3D), with measurements taken at a single frequency. At the core of our imaging system are two metasurface apertures, both of which consist of a linear array of metamaterial irises that couple to a common waveguide feed. Each metamaterial iris has integrated within it a diode that can be biased so as to switch the element on (radiating) or off (non-radiating), such that the metasurface antenna can produce distinct radiation profiles corresponding to different on/off patterns of the metamaterial element array. The electrically large size of the metasurface apertures enables resolution in range and one cross-range dimension, while aperture synthesis provides resolution in the other cross-range dimension. The demonstrated imaging capabilities of this system represent a step forward in the development of low-cost, high-performance 3D microwave imaging systems.

  4. Non-local propagation of correlations in long-range interacting quantum systems

    NASA Astrophysics Data System (ADS)

    Lee, A. C.; Richerme, P.; Gong, Z.-X.; Senko, C.; Smith, J.; Foss-Feig, M.; Michalakis, S.; Gorshkov, A. V.; Monroe, C.

    2014-05-01

    The maximum speed with which information can propagate in a many body quantum system can dictate how demanding the system is to describe numerically and also how quickly disparate sites can become correlated. While these kinds of phenomena may be difficult or even impossible for classical computers to describe, trapped ions provide an excellent platform for investigating this rich quantum many-body physics. Using single-site resolved state-dependent imaging, we experimentally determine the spatial and time-dependent correlations of a far-from-equilibrium quantum many-body system evolving under a long-range Ising- or XY-model Hamiltonian. For varying interaction ranges, we extract the shape of the ``light'' cone and measure the velocity with which correlations propagate through the system. In many cases, we find increasing propagation velocities, which violate the prediction for short-range interactions and, in one instance, cannot be explained by any existing theory. Our results show that even for modest system sizes, trapped ion quantum simulators are well poised to study complex many-body physics which are intractable to classical methods. This work is supported by grants from the U.S. Army Research Office with funding from the DARPA OLE program, IARPA, and the MURI program; and the NSF Physics Frontier Center at JQI.

  5. Many-Body Physics in Long-Range Interacting Quantum Systems

    NASA Astrophysics Data System (ADS)

    Zhu, Bihui

    Ultracold atomic and molecular systems provide a useful platform for understanding quantum many-body physics. Recent progresses in AMO experiments enable access to systems exhibiting long-range interactions, opening a window for exploring the interplay between long-range interactions and dissipation. In this thesis, I develop theoretical approaches to study non-equilibrium dynamics in systems where such interplay is crucial. I first focus on a system of KRb molecules, where dipolar interactions and fast chemical reactions coexist. Using a classical kinetic theory and Monte Carlo methods, I study the evaporative cooling in a quasi-two-dimensional trap, and develop a protocol to reach quantum degeneracy. I also study the case where molecules are loaded into an optical lattice, and show that the strong dissipation induces a quantum Zeno effect, which suppresses the molecule loss. The analysis requires including multiple bands to explain recent experimental measurements, and can be used to determine the molecular filling fraction. I also investigate a system of radiating atoms, which experience long-range elastic and dissipative interactions. I explore the collective behavior of atoms and the role of atomic motion. The model is validated by comparison with a recent light scattering experiment using Sr atoms. I also show that incoherently pumped dipoles can undergo a dynamical phase transition to synchronization, and study its signature in the quantum regime.

  6. The Arctic in the Twenty-First Century: Changing Biogeochemical Linkages across a Paraglacial Landscape of Greenland.

    PubMed

    Anderson, N John; Saros, Jasmine E; Bullard, Joanna E; Cahoon, Sean M P; McGowan, Suzanne; Bagshaw, Elizabeth A; Barry, Christopher D; Bindler, Richard; Burpee, Benjamin T; Carrivick, Jonathan L; Fowler, Rachel A; Fox, Anthony D; Fritz, Sherilyn C; Giles, Madeleine E; Hamerlik, Ladislav; Ingeman-Nielsen, Thomas; Law, Antonia C; Mernild, Sebastian H; Northington, Robert M; Osburn, Christopher L; Pla-Rabès, Sergi; Post, Eric; Telling, Jon; Stroud, David A; Whiteford, Erika J; Yallop, Marian L; Yde, Jacob C

    2017-02-01

    The Kangerlussuaq area of southwest Greenland encompasses diverse ecological, geomorphic, and climate gradients that function over a range of spatial and temporal scales. Ecosystems range from the microbial communities on the ice sheet and moisture-stressed terrestrial vegetation (and their associated herbivores) to freshwater and oligosaline lakes. These ecosystems are linked by a dynamic glacio-fluvial-aeolian geomorphic system that transports water, geological material, organic carbon and nutrients from the glacier surface to adjacent terrestrial and aquatic systems. This paraglacial system is now subject to substantial change because of rapid regional warming since 2000. Here, we describe changes in the eco- and geomorphic systems at a range of timescales and explore rapid future change in the links that integrate these systems. We highlight the importance of cross-system subsidies at the landscape scale and, importantly, how these might change in the near future as the Arctic is expected to continue to warm.

  7. The Arctic in the Twenty-First Century: Changing Biogeochemical Linkages across a Paraglacial Landscape of Greenland

    PubMed Central

    Anderson, N. John; Saros, Jasmine E.; Bullard, Joanna E.; Cahoon, Sean M. P.; McGowan, Suzanne; Bagshaw, Elizabeth A.; Barry, Christopher D.; Bindler, Richard; Burpee, Benjamin T.; Carrivick, Jonathan L.; Fowler, Rachel A.; Fox, Anthony D.; Fritz, Sherilyn C.; Giles, Madeleine E.; Hamerlik, Ladislav; Ingeman-Nielsen, Thomas; Law, Antonia C.; Mernild, Sebastian H.; Northington, Robert M.; Osburn, Christopher L.; Pla-Rabès, Sergi; Post, Eric; Telling, Jon; Stroud, David A.; Whiteford, Erika J.; Yallop, Marian L.; Yde, Jacob C.

    2017-01-01

    Abstract The Kangerlussuaq area of southwest Greenland encompasses diverse ecological, geomorphic, and climate gradients that function over a range of spatial and temporal scales. Ecosystems range from the microbial communities on the ice sheet and moisture-stressed terrestrial vegetation (and their associated herbivores) to freshwater and oligosaline lakes. These ecosystems are linked by a dynamic glacio-fluvial-aeolian geomorphic system that transports water, geological material, organic carbon and nutrients from the glacier surface to adjacent terrestrial and aquatic systems. This paraglacial system is now subject to substantial change because of rapid regional warming since 2000. Here, we describe changes in the eco- and geomorphic systems at a range of timescales and explore rapid future change in the links that integrate these systems. We highlight the importance of cross-system subsidies at the landscape scale and, importantly, how these might change in the near future as the Arctic is expected to continue to warm. PMID:28596614

  8. Quasiparticle engineering and entanglement propagation in a quantum many-body system.

    PubMed

    Jurcevic, P; Lanyon, B P; Hauke, P; Hempel, C; Zoller, P; Blatt, R; Roos, C F

    2014-07-10

    The key to explaining and controlling a range of quantum phenomena is to study how information propagates around many-body systems. Quantum dynamics can be described by particle-like carriers of information that emerge in the collective behaviour of the underlying system, the so-called quasiparticles. These elementary excitations are predicted to distribute quantum information in a fashion determined by the system's interactions. Here we report quasiparticle dynamics observed in a quantum many-body system of trapped atomic ions. First, we observe the entanglement distributed by quasiparticles as they trace out light-cone-like wavefronts. Second, using the ability to tune the interaction range in our system, we observe information propagation in an experimental regime where the effective-light-cone picture does not apply. Our results will enable experimental studies of a range of quantum phenomena, including transport, thermalization, localization and entanglement growth, and represent a first step towards a new quantum-optic regime of engineered quasiparticles with tunable nonlinear interactions.

  9. Multiple-frequency continuous wave ultrasonic system for accurate distance measurement

    NASA Astrophysics Data System (ADS)

    Huang, C. F.; Young, M. S.; Li, Y. C.

    1999-02-01

    A highly accurate multiple-frequency continuous wave ultrasonic range-measuring system for use in air is described. The proposed system uses a method heretofore applied to radio frequency distance measurement but not to air-based ultrasonic systems. The method presented here is based upon the comparative phase shifts generated by three continuous ultrasonic waves of different but closely spaced frequencies. In the test embodiment to confirm concept feasibility, two low cost 40 kHz ultrasonic transducers are set face to face and used to transmit and receive ultrasound. Individual frequencies are transmitted serially, each generating its own phase shift. For any given frequency, the transmitter/receiver distance modulates the phase shift between the transmitted and received signals. Comparison of the phase shifts allows a highly accurate evaluation of target distance. A single-chip microcomputer-based multiple-frequency continuous wave generator and phase detector was designed to record and compute the phase shift information and the resulting distance, which is then sent to either a LCD or a PC. The PC is necessary only for calibration of the system, which can be run independently after calibration. Experiments were conducted to test the performance of the whole system. Experimentally, ranging accuracy was found to be within ±0.05 mm, with a range of over 1.5 m. The main advantages of this ultrasonic range measurement system are high resolution, low cost, narrow bandwidth requirements, and ease of implementation.

  10. Comparison of the Infiniti vision and the series 20,000 Legacy systems.

    PubMed

    Fernández de Castro, Luis E; Solomon, Kerry D; Hu, Daniel J; Vroman, David T; Sandoval, Helga P

    2008-01-01

    To compare the efficiency of the Infiniti vision system and the Series 20,000 Legacy system phacoemulsification units during routine cataract extraction. Thirty-nine eyes of 39 patients were randomized to have their cataract removed using either the Infiniti or the Legacy system, both using the Neosonix handpiece. System settings were standardized. Ultrasound time, amount of balanced salt solution (BSS) used intraoperatively, and postoperative visual acuity at postoperative days 1, 7 and 30 were evaluated. Preoperatively, best corrected visual acuity was significantly worse in the Infiniti group compared to the Legacy group (0.38 +/- 0.23 and 0.21 +/- 0.16, respectively; p = 0.012). The mean phacoemulsification time was 39.6 +/- 22.9 s (range 6.0-102.0) for the Legacy group and 18.3 +/-19.1 s (range 1.0-80.0) for the Infiniti group (p = 0.001). The mean amounts of intraoperative BSS used were 117 +/- 37.7 ml (range 70-195) in the Legacy group and 85.3 +/- 38.9 ml (range 40-200) in the Infiniti group (p = 0.005). No differences in postoperative visual acuity were found. The ability to use higher flow rates and vacuum settings with the Infiniti vision system allowed for cataract removal with less phacoemulsification time than when using the Legacy system. Copyright 2008 S. Karger AG, Basel.

  11. Integration and Validation of a Thermal Energy Storage System for Electric Vehicle Cabin Heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Mingyu; Craig, Timothy; Wolfe, Edward

    It is widely recognized in the automotive industry that, in very cold climatic conditions, the driving range of an Electric Vehicle (EV) can be reduced by 50% or more. In an effort to minimize the EV range penalty, a novel thermal energy storage system has been designed to provide cabin heating in EVs and Plug-in Hybrid Electric Vehicles (PHEVs) by using an advanced phase change material (PCM). This system is known as the Electrical PCM-based Thermal Heating System (ePATHS) [1, 2]. When the EV is connected to the electric grid to charge its traction battery, the ePATHS system is alsomore » “charged” with thermal energy. The stored heat is subsequently deployed for cabin comfort heating during driving, for example during commuting to and from work.The ePATHS system, especially the PCM heat exchanger component, has gone through substantial redesign in order to meet functionality and commercialization requirements. The final system development for EV implementation has occurred on a mid-range EV and has been evaluated for its capability to extend the driving range. Both simulated driving in a climatic tunnel and actual road testing have been carried out. The ePATHS has demonstrated its ability to supply the entire cabin heating needs for a round trip commute totaling 46 minutes, including 8 hours of parking, at an ambient temperature of -10°C.« less

  12. Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.

    1994-01-01

    Accomplishments in the following areas of research are presented: receiver performance study of spaceborne laser altimeters and cloud and aerosol lidars; receiver performance analysis for space-to-space laser ranging systems; and receiver performance study for the Mars Environmental Survey (MESUR).

  13. Laser-photodetector timing station instruction and maintenance manual

    NASA Technical Reports Server (NTRS)

    Strader, E. A.

    1986-01-01

    A laser photodetector station is used for detecting the arrival of a projectile at a specific point along a ballistic range. The system can be employed on either an open or evacuated range, with small projectiles, and at hypervelocities. The setup procedures, maintenance, and system components are described.

  14. An Interdisciplinary Field Robotics Program for Undergraduate Computer Science and Engineering Education

    ERIC Educational Resources Information Center

    Kitts, Christopher; Quinn, Neil

    2004-01-01

    Santa Clara University's Robotic Systems Laboratory conducts an aggressive robotic development and operations program in which interdisciplinary teams of undergraduate students build and deploy a wide range of robotic systems, ranging from underwater vehicles to spacecraft. These year-long projects expose students to the breadth of and…

  15. Department of Defense Chemical, Biological, Radiological, and Nuclear Defense Program. FY2003-2005 Performance Plan

    DTIC Science & Technology

    2004-05-01

    Agents (NTAs) Compare the direct effects of PAF on smooth muscle, hematic constituents, and lung to determine role in toxicity. Continue to...baselined. Long Range Biometric Target ID System Explore technologies for a long range biometric target identification system. 3.5.1.6

  16. Design and performance evaluation of an interferometric controlled planar nanopositioning system

    NASA Astrophysics Data System (ADS)

    Hesse, S.; Schäffel, C.; Mohr, H.-U.; Katzschmann, M.; Büchner, H.-J.

    2012-07-01

    High technology applications for example in the semiconductor or the optical industry require positioning systems providing repeatability and uncertainty in the range of nanometers together with x-, y-travel ranges of several hundreds of millimeters. We contribute in this research by investigating the applicability of integrated planar direct drives for the realization of nanopositioning- and nanomeasuring machines (NPM/NMM). The paper introduces the concept of planar integrated direct drives and explains the engineering design of the realized system for a 100 mm circular travel range in x and y. It presents the drive system parameters and the arrangement and interaction of the main components. The results of the initial operation are presented with a special focus on the question how the closed loop system can be taken into operation with a free floating slider. The evaluation of the positioning performance leads to the result that a 2D servo error of less than exy = 1.3 nm is achieved at arbitrary positions within the travel range. As a result of repeated step response tests, the positioning resolution is 0.5 nm. The measurement of the coincidental z-movement of the aerostatically supported slider yields a z-vibration with a standard deviation of σz = 0.45 nm. Regarding the drive system these results represent the limit of what can be reached with this setup as the measured error motions are in the range of the noise of the fixed environment setup. By measuring the characteristics of the aerostatic slider support at the fully assembled system the present air bearing stiffness is determined and based on a FEM-simulation of the slider eigenfrequencies the influence on the force transfer behavior is expected to be only marginal.

  17. A Real Time Differential GPS Tracking System for NASA Sounding Rockets

    NASA Technical Reports Server (NTRS)

    Bull, Barton; Bauer, Frank (Technical Monitor)

    2000-01-01

    Sounding rockets are suborbital launch vehicles capable of carrying scientific payloads to several hundred miles in altitude. These missions return a variety of scientific data including: chemical makeup and physical processes taking place in the atmosphere, natural radiation surrounding the Earth, data on the Sun, stars, galaxies and many other phenomena. In addition, sounding rockets provide a reasonably economical means of conducting engineering tests for instruments and devices to be used on satellites and other spacecraft prior to their use in these more expensive missions. Typically around thirty of these rockets are launched each year, from established ranges at Wallops Island, Virginia; Poker Flat Research Range, Alaska; White Sands Missile Range, New Mexico and from a number of ranges outside the United States. Many times launches are conducted from temporary launch ranges in remote parts of the world requiring considerable expense to transport and operate tracking radars. In order to support these missions, an inverse differential GPS system has been developed. The flight system consists of a small, inexpensive receiver, a preamplifier and a wrap-around antenna. A rugged, compact, portable ground station extracts GPS data from the raw payload telemetry stream, performs a real time differential solution and graphically displays the rocket's path relative to a predicted trajectory plot. In addition to generating a real time navigation solution, the system has been used for payload recovery, timing, data timetagging, precise tracking of multiple payloads and slaving of optical tracking systems for over the horizon acquisition. This paper discusses, in detail, the flight and ground hardware, as well as data processing and operational aspects of the system, and provides evidence of the system accuracy.

  18. Evaluation of the performance of a novel system for continuous glucose monitoring.

    PubMed

    Zschornack, Eva; Schmid, Christina; Pleus, Stefan; Link, Manuela; Klötzer, Hans-Martin; Obermaier, Karin; Schoemaker, Michael; Strasser, Monika; Frisch, Gerhard; Schmelzeisen-Redeker, Günther; Haug, Cornelia; Freckmann, Guido

    2013-07-01

    The performance of a continuous glucose monitoring (CGM) system in the early stage of development was assessed in an inpatient setting that simulates daily life conditions of people with diabetes. Performance was evaluated at low glycemic, euglycemic, and high glycemic ranges as well as during phases with rapid glucose excursions. Each of the 30 participants with type 1 diabetes (15 female, age 47 ± 12 years, hemoglobin A1c 7.7% ± 1.3%) wore two sensors of the prototype system in parallel for 7 days. Capillary blood samples were measured at least 16 times per day (at least 15 times per daytime and at least once per night). On two subsequent study days, glucose excursions were induced. For performance evaluation, the mean absolute relative difference (MARD) between CGM readings and paired capillary blood glucose readings and precision absolute relative difference (PARD), i.e., differences between paired CGM readings were calculated. Overall aggregated MARD was 9.2% and overall aggregated PARD was 7.5%. During induced glucose excursions, MARD was 10.9% and PARD was 7.8%. Lowest MARD (8.5%) and lowest PARD (6.4%) were observed in the high glycemic range (euglycemic range, MARD 9.1% and PARD 7.4%; low glycemic range, MARD 12.3% and PARD 12.4%). The performance of this prototype CGM system was, particularly in the hypoglycemic range and during phases with rapid glucose fluctuations, better than performance data reported for other commercially available systems. In addition, performance of this prototype sensor was noticeably constant over the whole study period. This prototype system is not yet approved, and performance of this CGM system needs to be further assessed in clinical studies. © 2013 Diabetes Technology Society.

  19. Design and performance simulation of 532 nm Rayleigh-Mie Doppler lidar system for 5-50 km wind measurement

    NASA Astrophysics Data System (ADS)

    Shen, Fahua; Wang, Bangxin; Shi, Wenjuan; Zhuang, Peng; Zhu, Chengyun; Xie, Chenbo

    2018-04-01

    A novel design of the 532 nm Rayleigh-Mie Doppler lidar receiving system is carried out. The use of polarization isolation technology to effectively improve the receiving system optical reception efficiency, suppress the background noise, not only improves the system wind field detection accuracy, while achieving a high-accuracy temperature measurement. The wind speed and temperature measurement principle of the system are discussed in detail, and the triple Fabry-Perot etalon parameters are optimized. Utilizing the overall design parameters of the system, the system detection performance is simulated. The simulation results show that from 5 to 50 km altitude with vertical resolution of 0.1 km@5 ∼20 km, 0.5 km@20 ∼40 km, 1 km@40 ∼50 km, by using the laser with single pulse energy of 600 mJ, repetition frequency of 50 Hz and the receiving telescope with aperture of 0.8 m, with 2min integration time and in ±50 m/s radial wind speed range, the radial wind speed measurement accuracies of our designed lidar in the day and night are better than 2.6 m/s and 0.9 m/s respectively, and its performance is obviously superior to that of traditional system 5.6 m/s and 1.4 m/s wind speed accuracies; with 10min integration time and in 210 ∼280 K temperature range, the temperature measurement accuracies of the system in the day and night are better than 3.4 K and 1.2 K respectively; since the wind speed sensitivities of the Mie and Rayleigh scattering signals are not exactly the same, in ±50 m/s radial wind speed range, the wind speed bias induced by Mie signal is less than 1 m/s in the temperature range of 210-290 K and in the backscatter ratio range of 1-1.5 for pair measurement.

  20. Parameterizing Coefficients of a POD-Based Dynamical System

    NASA Technical Reports Server (NTRS)

    Kalb, Virginia L.

    2010-01-01

    A method of parameterizing the coefficients of a dynamical system based of a proper orthogonal decomposition (POD) representing the flow dynamics of a viscous fluid has been introduced. (A brief description of POD is presented in the immediately preceding article.) The present parameterization method is intended to enable construction of the dynamical system to accurately represent the temporal evolution of the flow dynamics over a range of Reynolds numbers. The need for this or a similar method arises as follows: A procedure that includes direct numerical simulation followed by POD, followed by Galerkin projection to a dynamical system has been proven to enable representation of flow dynamics by a low-dimensional model at the Reynolds number of the simulation. However, a more difficult task is to obtain models that are valid over a range of Reynolds numbers. Extrapolation of low-dimensional models by use of straightforward Reynolds-number-based parameter continuation has proven to be inadequate for successful prediction of flows. A key part of the problem of constructing a dynamical system to accurately represent the temporal evolution of the flow dynamics over a range of Reynolds numbers is the problem of understanding and providing for the variation of the coefficients of the dynamical system with the Reynolds number. Prior methods do not enable capture of temporal dynamics over ranges of Reynolds numbers in low-dimensional models, and are not even satisfactory when large numbers of modes are used. The basic idea of the present method is to solve the problem through a suitable parameterization of the coefficients of the dynamical system. The parameterization computations involve utilization of the transfer of kinetic energy between modes as a function of Reynolds number. The thus-parameterized dynamical system accurately predicts the flow dynamics and is applicable to a range of flow problems in the dynamical regime around the Hopf bifurcation. Parameter-continuation software can be used on the parameterized dynamical system to derive a bifurcation diagram that accurately predicts the temporal flow behavior.

  1. Nutrient balances as indicators for sustainability of broiler production systems.

    PubMed

    Kratz, S; Halle, I; Rogasik, J; Schnug, E

    2004-04-01

    1. Flock balances of nitrogen, phosphorus, zinc and copper (N, P, Zn, Cu) were calculated in order to evaluate environmental effects of three different broiler production systems (intensive indoor, free range and organic). 2. Nutrient gain in birds per unit nutrient intake (retention) in intensive indoor production was higher than in free range and organic production. 3. Nutrient surplus relative to nutrient retention was higher in organic production than in free range and intensive indoor production. 4. The main reasons for differences in nutrient efficiency between intensive indoor, free range and organic production were duration of growth period, strain of broilers and feeding strategy. 5. The calculation of whole farm indicators (livestock density, N and P excretions per hectare of farmland) demonstrates how defining system boundaries affects the outcome of an evaluation: organic farms had the smallest livestock densities and the lowest N and P excretions per hectare of farmland. 6. In the efforts to reach a more holistic evaluation of agricultural production systems, the definition of adequate system boundaries must be discussed. In addition to nutrient balances, further indicators of sustainability, such as human and ecological toxicity, should be considered.

  2. Three-dimensional anterior segment imaging in patients with type 1 Boston Keratoprosthesis with switchable full depth range swept source optical coherence tomography

    PubMed Central

    Poddar, Raju; Cortés, Dennis E.; Werner, John S.; Mannis, Mark J.

    2013-01-01

    Abstract. A high-speed (100 kHz A-scans/s) complex conjugate resolved 1 μm swept source optical coherence tomography (SS-OCT) system using coherence revival of the light source is suitable for dense three-dimensional (3-D) imaging of the anterior segment. The short acquisition time helps to minimize the influence of motion artifacts. The extended depth range of the SS-OCT system allows topographic analysis of clinically relevant images of the entire depth of the anterior segment of the eye. Patients with the type 1 Boston Keratoprosthesis (KPro) require evaluation of the full anterior segment depth. Current commercially available OCT systems are not suitable for this application due to limited acquisition speed, resolution, and axial imaging range. Moreover, most commonly used research grade and some clinical OCT systems implement a commercially available SS (Axsun) that offers only 3.7 mm imaging range (in air) in its standard configuration. We describe implementation of a common swept laser with built-in k-clock to allow phase stable imaging in both low range and high range, 3.7 and 11.5 mm in air, respectively, without the need to build an external MZI k-clock. As a result, 3-D morphology of the KPro position with respect to the surrounding tissue could be investigated in vivo both at high resolution and with large depth range to achieve noninvasive and precise evaluation of success of the surgical procedure. PMID:23912759

  3. Advanced technologies in the ASI MLRO towards a new generation laser ranging system

    NASA Technical Reports Server (NTRS)

    Varghese, Thomas; Bianco, Giuseppe

    1994-01-01

    Matera Laser Ranging Observatory (MLRO) is a high performance, highly automated optical and astronomical observatory currently under design and development by AlliedSignal for the Italian Space Agency (ASI). It is projected to become operational at the Centro Geodesia Spaziale in Matera, Italy, in 1997. MLRO, based on a 1.5-meter astronomical quality telescope, will perform ranging to spacecraft in earthbound orbits, lunar reflectors, and specially equipped deep space missions. The primary emphasis during design is to incorporate state-of-the-art technologies to produce an intelligent, automated, high accuracy ranging system that will mimic the characteristic features of a fifth generation laser ranging system. The telescope has multiple ports and foci to support future experiments in the areas of laser communications, lidar, astrometry, etc. The key features providing state-of-the-art ranging performance include: a diode-pumped picosecond (50 ps) laser, high speed (3-5 GHz) optoelectronic detection and signal processing, and a high accuracy (6 ps) high resolution (less than 2 ps) time measurement capability. The above combination of technologies is expected to yield millimeter laser ranging precision and accuracy on targets up to 300,000 km, surpassing the best operational instrument performance to date by a factor of five or more. Distributed processing and control using a state-of-the-art computing environment provides the framework for efficient operation, system optimization, and diagnostics. A computationally intelligent environment permits optimal planning, scheduling, tracking, and data processing. It also supports remote access, monitor, and control for joint experiments with other observatories.

  4. New Primary Dew-Point Generators at HMI/FSB-LPM in the Range from -70 °C to +60 °C

    NASA Astrophysics Data System (ADS)

    Zvizdic, Davor; Heinonen, Martti; Sestan, Danijel

    2012-09-01

    To extend the dew-point range and to improve the uncertainties of the humidity scale realization at HMI/FSB-LPM, new primary low- and high-range dew-point generators were developed and implemented in cooperation with MIKES, in 2009 through EUROMET Project No. 912. The low-range saturator is designed for primary realization of the dew-point temperature scale from -70 °C to + 5 °C, while the high-range saturator covers the range from 1 °C to 60 °C. The system is designed as a single-pressure, single-pass dew-point generator. MIKES designed and constructed both the saturators to be implemented in dew-point calibration systems at LPM. The LPM took care of purchasing and adapting liquid baths, of implementing the temperature and pressure measurement equipment appropriate for use in the systems, and development of gas preparation and flow control systems as well as of the computer-based automated data acquisition. The principle and the design of the generator are described in detail and schematically depicted. The tests were performed at MIKES to investigate how close both the saturators are to an ideal saturator. Results of the tests show that both the saturators are efficient enough for a primary realization of the dew-point temperature scale from -70 °C to + 60 °C, in the specified flow-rate ranges. The estimated standard uncertainties due to the non-ideal saturation efficiency are between 0.02 °C and 0.05 °C.

  5. Design and implementation of a low-cost multiple-range digital phase detector

    NASA Astrophysics Data System (ADS)

    Omran, Hesham; Albasha, Lutfi; Al-Ali, A. R.

    2012-06-01

    This article describes the design, simulation, implementation and testing of a novel low-cost multiple-range programmable digital phase detector. The detector receives two periodic signals and calculates the ratio of the time difference to the time period to measure and display the phase difference. The resulting output values are in integer form ranging from -180° to 180°. Users can select the detector pre-set operation frequency ranges using a three-bit pre-scalar. This enables to use the detector for various applications. The proposed detector can be programmed over a frequency range of 10 Hz to 25 kHz by configuring its clock divider circuit. Detector simulations were conducted and verified using ModelSim and the design was implemented and tested using an Altera Cyclone II field-programmable gate array board. Both the simulation and actual circuit testing results showed that the phase detector has a magnitude of error of only 1°. The detector is ideal for applications such as power factor measurement and correction, self-tuning resonant circuits and in metal detection systems. Unlike other stand-alone phase detection systems, the reported system has the ability to be programmed to several frequency ranges, hence expanding its bandwidth.

  6. Bacterial contamination of eggs and behaviour of poultry flocks in the free range environment.

    PubMed

    Moyle, Talia; Drake, Kelly; Gole, Vaibhav; Chousalkar, Kapil; Hazel, Susan

    2016-12-01

    The free range production system is becoming more common in Australia and is expected to increase. Free range hens are exposed to more stressors in comparison to hens from barn and cage systems and it is suggested that stress can increase bacterial shedding on eggs. The aims of this study were to examine the level of total bacteria and Enterobacteriaceae populations, as well as the presence of Salmonella and Campylobacter, in eggs collected from two free range flocks on two different farms and to conduct longitudinal observations of the behaviour and welfare of hens in the free range production system. Hen age (weeks) was shown to have a significant effect (increase) on the level of total bacteria on the egg shell surface and in shell pores, as well as having an effect on feather condition score. As the hens aged, the frequency of external visual egg characteristics increased, as did feather condition score (where feather condition was poorer). These observations indicate areas which should be investigated further to improve the food safety of eggs and optimise the welfare of free range hens. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  7. Effective-range parameters and vertex constants for Λ-nuclear systems

    NASA Astrophysics Data System (ADS)

    Rakityansky, S. A.; Gopane, I. M.

    For a wide range of the core-nuclei (6 ≤ A ≤ 207), the scattering lengths, effective radii, and the other effective-range parameters (up to the order ˜ k8) for the angular momentum ℓ = 0, 1, 2 are calculated within a two-body ΛA-model. For the same hypernuclear systems, the S-matrix residues as well as the corresponding Nuclear-Vertex and Asymptotic-Normalization constants (NVC’s and ANC’s) for the bound states are also found.

  8. Laboratory test results of the high speed optical tracking system for the Spaceborne Geodynamic Ranging System

    NASA Technical Reports Server (NTRS)

    Zagwodzki, Thomas W.; White, David L.

    1987-01-01

    The high speed, high resolution optical tracking system for the Spaceborne Geodynamic Ranging System employs a two-axis gimbaled pointing device that can operate from a Space Shuttle platform and can track multiple retroreflector ground targets with arcsec accuracy. Laboratory tests of the stepping characteristics of the pointing system for various step sizes and directions has shown arcsec repeatability with little wasted motion, overshoot, or ringing. The worst rms tracking jitter was 1 and 2 arcsec in the roll and pitch axes, respectively, at the maximum tracking rate of 2 deg/sec.

  9. Assessment and preliminary design of an energy buffer for regenerative braking in electric vehicles

    NASA Technical Reports Server (NTRS)

    Buchholz, R.; Mathur, A. K.

    1979-01-01

    Energy buffer systems, capable of storing the vehicle energy during braking and reusing this stored energy during acceleration, were examined. Some of these buffer systems when incorporated in an electric vehicle would result in an improvement in the performance and range under stop and go driving conditions. Buffer systems considered included flywheels, hydropneumatic, pneumatic, spring, and regenerative braking. Buffer ranking and rating criteria were established. Buffer systems were rated based on predicted range improvements, consumer acceptance, driveability, safety, reliability and durability, and initial and life cycle costs. A hydropneumatic buffer system was selected.

  10. Many-body delocalization in a strongly disordered system with long-range interactions: Finite-size scaling

    NASA Astrophysics Data System (ADS)

    Burin, Alexander L.

    2015-03-01

    Many-body localization in a disordered system of interacting spins coupled by the long-range interaction 1 /Rα is investigated combining analytical theory considering resonant interactions and a finite-size scaling of exact numerical solutions with number of spins N . The numerical results for a one-dimensional system are consistent with the general expectations of analytical theory for a d -dimensional system including the absence of localization in the infinite system at α <2 d and a universal scaling of a critical energy disordering Wc∝N2/d -α d .

  11. A Kinect based intelligent e-rehabilitation system in physical therapy.

    PubMed

    Gal, Norbert; Andrei, Diana; Nemeş, Dan Ion; Nădăşan, Emanuela; Stoicu-Tivadar, Vasile

    2015-01-01

    This paper presents an intelligent Kinect and fuzzy inference system based e-rehabilitation system. The Kinect can detect the posture and motion of the patients while the fuzzy inference system can interpret the acquired data on the cognitive level. The system is capable to assess the initial posture and motion ranges of 20 joints. Using angles to describe the motion of the joints, exercise patterns can be developed for each patient. Using the exercise descriptors the fuzzy inference system can track the patient and deliver real-time feedback to maximize the efficiency of the rehabilitation. The first laboratory tests confirm the utility of this system for the initial posture detection, motion range and exercise tracking.

  12. Influence of target reflection on three-dimensional range gated reconstruction.

    PubMed

    Chua, Sing Yee; Wang, Xin; Guo, Ningqun; Tan, Ching Seong

    2016-08-20

    The range gated technique is a promising laser ranging method that is widely used in different fields such as surveillance, industry, and military. In a range gated system, a reflected laser pulse returned from the target scene contains key information for range reconstruction, which directly affects the system performance. Therefore, it is necessary to study the characteristics and effects of the target reflection factor. In this paper, theoretical and experimental analyses are performed to investigate the influence of target reflection on three-dimensional (3D) range gated reconstruction. Based on laser detection and ranging (LADAR) and bidirectional reflection distribution function (BRDF) theory, a 3D range gated reconstruction model is derived and the effect on range accuracy is analyzed from the perspectives of target surface reflectivity and angle of laser incidence. Our theoretical and experimental study shows that the range accuracy is proportional to the target surface reflectivity, but it decreases when the angle of incidence increases to adhere to the BRDF model. The presented findings establish a comprehensive understanding of target reflection in 3D range gated reconstruction, which is of interest to various applications such as target recognition and object modeling. This paper provides a reference for future improvement to perform accurate range compensation or correction.

  13. Design of voice coil motor dynamic focusing unit for a laser scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Moon G.; Kim, Gaeun; Lee, Chan-Woo

    2014-04-15

    Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motorsmore » and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden–Fletcher–Goldfarb–Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.« less

  14. Online support system for students in higher education: Proof-of-concept study

    PubMed Central

    Touloumakos, Anna K; Goozée, Rhianna; Papadatou-Pastou, Marietta; Barley, Elizabeth; Haddad, Mark; Tzotzoli, Patapia

    2016-01-01

    Background Providing support to the increasing numbers of students facing mental health difficulties in higher education (HE) can be difficult due to stigma or lack of resources. Alternative and/or complementary sources of support are needed, such as online interventions that are recognised for their therapeutic value and cost-effectiveness. Objectives We aim to provide evidence supporting the conceptual and practical value of a newly developed online multimedia intervention system for HE students who face mild to moderate symptoms of anxiety and depression and study-skills difficulties. Methods Students from five universities were invited to participate in a cross-sectional proof-of-concept study. Students were invited through the universities’ internal communication channels. Following demonstration of each part of the system, students completed a survey with quantitative and qualitative questions. Results Response was largely positive. Positive responses on the features of the questionnaire ranged between 65% and 86%; on the features of the workshops ranged between 57% and 91%; on ‘My place’ ranged between 65% and 79%; on the animated videos ranged between 79% and 92%; and on the overall system ranged between 78% and 89%. Participants indicated areas for improvement and ways in which such improvement could be accomplished; these then guided the development of the system. Conclusions The results confirm the need for such a system. It can complement student support services (SSS) by dealing with cases with mild to moderate difficulties, hence allowing SSS to prioritise and effectively address more severe cases. Potentially this method can provide a meaningful alternative to SSS; this is worth investigating further.

  15. DARPA super resolution vision system (SRVS) robust turbulence data collection and analysis

    NASA Astrophysics Data System (ADS)

    Espinola, Richard L.; Leonard, Kevin R.; Thompson, Roger; Tofsted, David; D'Arcy, Sean

    2014-05-01

    Atmospheric turbulence degrades the range performance of military imaging systems, specifically those intended for long range, ground-to-ground target identification. The recent Defense Advanced Research Projects Agency (DARPA) Super Resolution Vision System (SRVS) program developed novel post-processing system components to mitigate turbulence effects on visible and infrared sensor systems. As part of the program, the US Army RDECOM CERDEC NVESD and the US Army Research Laboratory Computational & Information Sciences Directorate (CISD) collaborated on a field collection and atmospheric characterization of a two-handed weapon identification dataset through a diurnal cycle for a variety of ranges and sensor systems. The robust dataset is useful in developing new models and simulations of turbulence, as well for providing as a standard baseline for comparison of sensor systems in the presence of turbulence degradation and mitigation. In this paper, we describe the field collection and atmospheric characterization and present the robust dataset to the defense, sensing, and security community. In addition, we present an expanded model validation of turbulence degradation using the field collected video sequences.

  16. Robust range estimation with a monocular camera for vision-based forward collision warning system.

    PubMed

    Park, Ki-Yeong; Hwang, Sun-Young

    2014-01-01

    We propose a range estimation method for vision-based forward collision warning systems with a monocular camera. To solve the problem of variation of camera pitch angle due to vehicle motion and road inclination, the proposed method estimates virtual horizon from size and position of vehicles in captured image at run-time. The proposed method provides robust results even when road inclination varies continuously on hilly roads or lane markings are not seen on crowded roads. For experiments, a vision-based forward collision warning system has been implemented and the proposed method is evaluated with video clips recorded in highway and urban traffic environments. Virtual horizons estimated by the proposed method are compared with horizons manually identified, and estimated ranges are compared with measured ranges. Experimental results confirm that the proposed method provides robust results both in highway and in urban traffic environments.

  17. Robust Range Estimation with a Monocular Camera for Vision-Based Forward Collision Warning System

    PubMed Central

    2014-01-01

    We propose a range estimation method for vision-based forward collision warning systems with a monocular camera. To solve the problem of variation of camera pitch angle due to vehicle motion and road inclination, the proposed method estimates virtual horizon from size and position of vehicles in captured image at run-time. The proposed method provides robust results even when road inclination varies continuously on hilly roads or lane markings are not seen on crowded roads. For experiments, a vision-based forward collision warning system has been implemented and the proposed method is evaluated with video clips recorded in highway and urban traffic environments. Virtual horizons estimated by the proposed method are compared with horizons manually identified, and estimated ranges are compared with measured ranges. Experimental results confirm that the proposed method provides robust results both in highway and in urban traffic environments. PMID:24558344

  18. Late Cretaceous stratigraphy, deformation and intrusion in the Madison Range of southwestern Montana ( USA).

    USGS Publications Warehouse

    Tysdal, R.G.; Marvin, R.F.; Dewitt, E.

    1986-01-01

    Dating of orogenic rock units in the central part of the Madison Range shows that Laramide deformation was virtually completed by the end of the Cretaceous. Early Campanian K-Ar dates of about 79 m.y. were obtained from welded tuffs in the basal part of the Livingston Formation, a volcanic and volcaniclastic assemblage that is conformable with underlying Cretaceous clastic rocks and with the overlying Sphinx Conglomerate. The Sphinx and the Livingston were deformed by the Hilgard fault system which extends along the western side of the southern two-thirds of the range. This north-trending fault system represents the culmination of Laramide shortening within the range. Dating of hornblende indicates an approximate date of 68-69 m.y. B.P. for emplacement of the igneous suite. The dacite postdates movement along faults of the Hilgard fault system, and postdates the synorogenic Sphinx Conglomerate. -from Authors

  19. Correlation range in a supercooled liquid via Green-Kubo expression for viscosity, local atomic stresses, and MD simulations

    NASA Astrophysics Data System (ADS)

    Levashov, Valentin A.; Egami, Takeshi; Morris, James R.

    2009-03-01

    We present a new approach to the issue of correlation range in supercooled liquids based on Green-Kubo expression for viscosity. The integrand of this expression is the average stress-stress autocorrelation function. This correlation function could be rewritten in terms of correlations among local atomic stresses at different times and distances. The features of the autocorrelation function decay with time depend on temperature and correlation range. Through this approach we can study the development of spatial correlation with time, thus directly addressing the question of dynamic heterogeneity. We performed MD simulations on a single component system of particles interacting through short range pair potential. Our results indicate that even above the crossover temperature correlations extend well beyond the nearest neighbors. Surprisingly we found that the system size effects exist even on relatively large systems. We also address the role of diffusion in decay of stress-stress correlation function.

  20. Importance of non-flow in mixed-harmonic multi-particle correlations in small collision systems

    NASA Astrophysics Data System (ADS)

    Huo, Peng; Gajdošová, Katarína; Jia, Jiangyong; Zhou, You

    2018-02-01

    Recently CMS Collaboration measured mixed-harmonic four-particle azimuthal correlations, known as symmetric cumulants SC (n , m), in pp and p+Pb collisions, and interpreted the non-zero SC (n , m) as evidence for long-range collectivity in these small collision systems. Using the PYTHIA and HIJING models which do not have genuine long-range collectivity, we show that the CMS results, obtained with standard cumulant method, could be dominated by non-flow effects associated with jet and dijets, especially in pp collisions. We show that the non-flow effects are largely suppressed using the recently proposed subevent cumulant methods by requiring azimuthal correlation between two or more pseudorapidity ranges. We argue that the reanalysis of SC (n , m) using the subevent method in experiments is necessary before they can used to provide further evidences for a long-range multi-particle collectivity and constraints on theoretical models in small collision systems.

  1. Long-range Prethermal Time Crystals

    NASA Astrophysics Data System (ADS)

    Machado, Francisco; Meyer, Gregory D.; Else, Dominic; Olund, Christopher; Nayak, Chetan; Yao, Norman Y.

    2017-04-01

    Driven quantum systems have recently enabled the realization of a discrete time crystal - an intrinsically out-of-equilibrium phase of matter. One strategy to prevent the drive-induced, runaway heating of the time crystal is the presence of strong disorder leading to many-body localization (MBL). A more elegant, disorder-less approach is simply to work in the prethermal regime where time crystalline order can persist to exponentially long times. One key difference between prethermal and MBL time crystals is that the former is prohibited from existing in one dimensional systems with short-range interactions. In this work, we demonstrate that long-range interactions can stabilize a one dimensional prethermal time crystal. By numerically studying the pre-thermal regime, we find evidence for a phase transition out of the time crystal as a function of increasing energy density. Finally, generalizations of previous analytical bounds for the heating time-scale of driven quantum systems to long-range interactions will also be discussed.

  2. An underwater ranging system based on photoacoustic effect occurring on target surface

    NASA Astrophysics Data System (ADS)

    Ni, Kai; Hu, Kai; Li, Xinghui; Wang, Lidai; Zhou, Qian; Wang, Xiaohao

    2016-11-01

    In this paper, an underwater ranging system based on photoacoustic effect occurring on target surface is proposed. In this proposal, laser pulse generated by blue-green laser is directly incident on target surface, where the photoacoustic effect occurs and a sound source is formed. And then the sound wave which is also called photoacoustic signal is received by the ultrasonic receiver after passing through water. According to the time delay between transmitting laser and receiving photoacoustic signal, and sound velocity in water, the distance between the target and the ultrasonic receiver can be calculated. Differing from underwater range finding by only laser, this approach can avoid backscattering of laser beam, so easier to implement. Experimental system according to this principle has been constructed to verify the feasibility of this technology. The experimental results showed that a ranging accuracy of 1 mm can be effectively achieved when the target is close to the ultrasonic receiver.

  3. Digital micromirror device camera with per-pixel coded exposure for high dynamic range imaging.

    PubMed

    Feng, Wei; Zhang, Fumin; Wang, Weijing; Xing, Wei; Qu, Xinghua

    2017-05-01

    In this paper, we overcome the limited dynamic range of the conventional digital camera, and propose a method of realizing high dynamic range imaging (HDRI) from a novel programmable imaging system called a digital micromirror device (DMD) camera. The unique feature of the proposed new method is that the spatial and temporal information of incident light in our DMD camera can be flexibly modulated, and it enables the camera pixels always to have reasonable exposure intensity by DMD pixel-level modulation. More importantly, it allows different light intensity control algorithms used in our programmable imaging system to achieve HDRI. We implement the optical system prototype, analyze the theory of per-pixel coded exposure for HDRI, and put forward an adaptive light intensity control algorithm to effectively modulate the different light intensity to recover high dynamic range images. Via experiments, we demonstrate the effectiveness of our method and implement the HDRI on different objects.

  4. Local birefringence of the anterior segment of the human eye in a single capture with a full range polarisation-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Li, Qingyun; Karnowski, Karol; Villiger, Martin; Sampson, David D.

    2017-04-01

    A fibre-based full-range polarisation-sensitive optical coherence tomography system is developed to enable complete capture of the structural and birefringence properties of the anterior segment of the human eye in a single acquisition. The system uses a wavelength swept source centered at 1.3 μm, passively depth-encoded, orthogonal polarisation states in the illumination path and polarisation-diversity detection. Off-pivot galvanometer scanning is used to extend the imaging range and compensate for sensitivity drop-off. A Mueller matrix-based method is used to analyse data. We demonstrate the performance of the system and discuss issues relating to its optimisation.

  5. An automated system to measure the quantum efficiency of CCDs for astronomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coles, R.; Chiang, J.; Cinabro, D.

    We describe a system to measure the Quantum Efficiency in the wavelength range of 300 nm to 1100 nm of 40 × 40 mm n-channel CCD sensors for the construction of the 3.2 gigapixel LSST focal plane. The technique uses a series of instrument to create a very uniform flux of photons of controllable intensity in the wavelength range of interest across the face the sensor. This allows the absolute Quantum Efficiency to be measured with an accuracy in the 1% range. Finally, this system will be part of a production facility at Brookhaven National Lab for the basic componentmore » of the LSST camera.« less

  6. An automated system to measure the quantum efficiency of CCDs for astronomy

    DOE PAGES

    Coles, R.; Chiang, J.; Cinabro, D.; ...

    2017-04-18

    We describe a system to measure the Quantum Efficiency in the wavelength range of 300 nm to 1100 nm of 40 × 40 mm n-channel CCD sensors for the construction of the 3.2 gigapixel LSST focal plane. The technique uses a series of instrument to create a very uniform flux of photons of controllable intensity in the wavelength range of interest across the face the sensor. This allows the absolute Quantum Efficiency to be measured with an accuracy in the 1% range. Finally, this system will be part of a production facility at Brookhaven National Lab for the basic componentmore » of the LSST camera.« less

  7. An Overview of the Antenna Measurement Facilities at the NASA Glenn Research Center

    NASA Astrophysics Data System (ADS)

    Lambert, Kevin M.; Anzic, Godfrey; Zakrajsek, Robert J.; Zaman, Afroz J.

    2002-10-01

    For the past twenty years, the NASA Glenn Research Center (formerly Lewis Research Center) in Cleveland, Ohio, has developed and maintained facilities for the evaluation of antennas. This effort has been in support of the work being done at the center in the research and development of space communication systems. The wide variety of antennas that have been considered for these systems resulted in a need for several types of antenna ranges at the Glenn Research Center. Four ranges, which are part of the Microwave Systems Laboratory, are the responsibility of the staff of the Applied RF Technology Branch. A general description of these ranges is provided in this paper.

  8. An Overview of the Antenna Measurement Facilities at the NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Lambert, Kevin M.; Anzic, Godfrey; Zakrajsek, Robert J.; Zaman, Afroz J.

    2002-01-01

    For the past twenty years, the NASA Glenn Research Center (formerly Lewis Research Center) in Cleveland, Ohio, has developed and maintained facilities for the evaluation of antennas. This effort has been in support of the work being done at the center in the research and development of space communication systems. The wide variety of antennas that have been considered for these systems resulted in a need for several types of antenna ranges at the Glenn Research Center. Four ranges, which are part of the Microwave Systems Laboratory, are the responsibility of the staff of the Applied RF Technology Branch. A general description of these ranges is provided in this paper.

  9. A human factors approach to range scheduling for satellite control

    NASA Technical Reports Server (NTRS)

    Wright, Cameron H. G.; Aitken, Donald J.

    1991-01-01

    Range scheduling for satellite control presents a classical problem: supervisory control of a large-scale dynamic system, with unwieldy amounts of interrelated data used as inputs to the decision process. Increased automation of the task, with the appropriate human-computer interface, is highly desirable. The development and user evaluation of a semi-automated network range scheduling system is described. The system incorporates a synergistic human-computer interface consisting of a large screen color display, voice input/output, a 'sonic pen' pointing device, a touchscreen color CRT, and a standard keyboard. From a human factors standpoint, this development represents the first major improvement in almost 30 years to the satellite control network scheduling task.

  10. Long-range analysis of density fitting in extended systems

    NASA Astrophysics Data System (ADS)

    Varga, Scarontefan

    Density fitting scheme is analyzed for the Coulomb problem in extended systems from the correctness of long-range behavior point of view. We show that for the correct cancellation of divergent long-range Coulomb terms it is crucial for the density fitting scheme to reproduce the overlap matrix exactly. It is demonstrated that from all possible fitting metric choices the Coulomb metric is the only one which inherently preserves the overlap matrix for infinite systems with translational periodicity. Moreover, we show that by a small additional effort any non-Coulomb metric fit can be made overlap-preserving as well. The problem is analyzed for both ordinary and Poisson basis set choices.

  11. Detection, Identification, Location, and Remote Sensing Using SAW RFID Sensor Tags

    NASA Technical Reports Server (NTRS)

    Barton, Richard J.; Kennedy, Timothy F.; Williams, Robert M.; Fink, Patrick W.; Ngo, Phong H.

    2009-01-01

    The Electromagnetic Systems Branch (EV4) of the Avionic Systems Division at NASA Johnson Space Center in Houston, TX is studying the utility of surface acoustic wave (SAW) radiofrequency identification (RFID) tags for multiple wireless applications including detection, identification, tracking, and remote sensing of objects on the lunar surface, monitoring of environmental test facilities, structural shape and health monitoring, and nondestructive test and evaluation of assets. For all of these applications, it is anticipated that the system utilized to interrogate the SAW RFID tags may need to operate at fairly long range and in the presence of considerable multipath and multiple-access interference. Towards that end, EV4 is developing a prototype SAW RFID wireless interrogation system for use in such environments called the Passive Adaptive RFID Sensor Equipment (PARSED) system. The system utilizes a digitally beam-formed planar receiving antenna array to extend range and provide direction-of-arrival information coupled with an approximate maximum-likelihood signal processing algorithm to provide near-optimal estimation of both range and temperature. The system is capable of forming a large number of beams within the field of view and resolving the information from several tags within each beam. The combination of both spatial and waveform discrimination provides the capability to track and monitor telemetry from a large number of objects appearing simultaneously within the field of view of the receiving array. In this paper, we will consider the application of the PARSEQ system to the problem of simultaneous detection, identification, localization, and temperature estimation for multiple objects. We will summarize the overall design of the PARSEQ system and present a detailed description of the design and performance of the signal detection and estimation algorithms incorporated in the system. The system is currently configured only to measure temperature (jointly with range and tag ID), but future versions will be revised to measure parameters other than temperature as SAW tags capable of interfacing with external sensors become available. It is anticipated that the estimation of arbitrary parameters measured using SAW-based sensors will be based on techniques very similar to the joint range and temperature estimation techniques described in this paper.

  12. Preliminary design of a mini-Brayton Compressor-Alternator-Turbine (CAT)

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The preliminary design of a mini-Brayton compressor-alternator-turbine system is discussed. The program design goals are listed. The optimum system characteristics over the entire range of power output were determined by performing a wide-range parametric study. The ability to develop the required components to the degree necessary within the limitations of present technology is evaluated. The sensitivity of the system to various individual design parameters was analyzed.

  13. Radio Ranging System for Guidance of Approaching Spacecraft

    NASA Technical Reports Server (NTRS)

    Manikonda, Vikram; vanDoom, Eric

    2008-01-01

    A radio communication and ranging system has been proposed for determining the relative position and orientations of two approaching spacecraft to provide guidance for docking maneuvers. On Earth, the system could be used similarly for guiding approaching aircraft and for automated positioning of large, heavy objects. In principle, the basic idea is to (1) measure distances between radio transceivers on the two spacecraft and (2) compute the relative position and orientations from the measured distances.

  14. Range and mission scheduling automation using combined AI and operations research techniques

    NASA Technical Reports Server (NTRS)

    Arbabi, Mansur; Pfeifer, Michael

    1987-01-01

    Ground-based systems for Satellite Command, Control, and Communications (C3) operations require a method for planning, scheduling and assigning the range resources such as: antenna systems scattered around the world, communications systems, and personnel. The method must accommodate user priorities, last minute changes, maintenance requirements, and exceptions from nominal requirements. Described are computer programs which solve 24 hour scheduling problems, using heuristic algorithms and a real time interactive scheduling process.

  15. A Novel Range-Extended Strategy for Fuel Cell/Battery Electric Vehicles.

    PubMed

    Hwang, Jenn-Jiang; Hu, Jia-Sheng; Lin, Chih-Hong

    2015-01-01

    The range-extended electric vehicle is proposed to improve the range anxiety drivers have of electric vehicles. Conventionally, a gasoline/diesel generator increases the range of an electric vehicle. Due to the zero-CO2 emission stipulations, utilizing fuel cells as generators raises concerns in society. This paper presents a novel charging strategy for fuel cell/battery electric vehicles. In comparison to the conventional switch control, a fuzzy control approach is employed to enhance the battery's state of charge (SOC). This approach improves the quick loss problem of the system's SOC and thus can achieve an extended driving range. Smooth steering experience and range extension are the main indexes for development of fuzzy rules, which are mainly based on the energy management in the urban driving model. Evaluation of the entire control system is performed by simulation, which demonstrates its effectiveness and feasibility.

  16. A Novel Range-Extended Strategy for Fuel Cell/Battery Electric Vehicles

    PubMed Central

    Hwang, Jenn-Jiang; Lin, Chih-Hong

    2015-01-01

    The range-extended electric vehicle is proposed to improve the range anxiety drivers have of electric vehicles. Conventionally, a gasoline/diesel generator increases the range of an electric vehicle. Due to the zero-CO2 emission stipulations, utilizing fuel cells as generators raises concerns in society. This paper presents a novel charging strategy for fuel cell/battery electric vehicles. In comparison to the conventional switch control, a fuzzy control approach is employed to enhance the battery's state of charge (SOC). This approach improves the quick loss problem of the system's SOC and thus can achieve an extended driving range. Smooth steering experience and range extension are the main indexes for development of fuzzy rules, which are mainly based on the energy management in the urban driving model. Evaluation of the entire control system is performed by simulation, which demonstrates its effectiveness and feasibility. PMID:26236771

  17. Long-range repulsion of colloids driven by ion exchange and diffusiophoresis

    PubMed Central

    Florea, Daniel; Musa, Sami; Huyghe, Jacques M. R.; Wyss, Hans M.

    2014-01-01

    Interactions between surfaces and particles in aqueous suspension are usually limited to distances smaller than 1 μm. However, in a range of studies from different disciplines, repulsion of particles has been observed over distances of up to hundreds of micrometers, in the absence of any additional external fields. Although a range of hypotheses have been suggested to account for such behavior, the physical mechanisms responsible for the phenomenon still remain unclear. To identify and isolate these mechanisms, we perform detailed experiments on a well-defined experimental system, using a setup that minimizes the effects of gravity and convection. Our experiments clearly indicate that the observed long-range repulsion is driven by a combination of ion exchange, ion diffusion, and diffusiophoresis. We develop a simple model that accounts for our data; this description is expected to be directly applicable to a wide range of systems exhibiting similar long-range forces. PMID:24748113

  18. A digital wide range neutron flux measuring system for HL-2A

    NASA Astrophysics Data System (ADS)

    Yuan, Chen; Wu, Jun; Yin, Zejie

    2017-08-01

    To achieve wide-range, high-integration, and real-time performance on the neutron flux measurement on the HL-2A tokamak, a digital neutron flux measuring (DNFM) system based on the peripheral component interconnection (PCI) eXtension for Instrumentation express (PXIe) bus was designed. This system comprises a charge-sensitive preamplifier and a field programmable gate array (FPGA)-based main electronics plug-in. The DNFM totally covers source-range and intermediate-range neutron flux measurements, and increases system integration by a large margin through joining the pulse-counting mode and Campbell mode. Meanwhile, the neutron flux estimation method based on pulse piling proportions is able to choose and switch measuring modes in accordance with current flux, and this ensures the accuracy of measurements when the neutron flux changes suddenly. It has been demonstrated by simulated signals that the DNFM enhances the full-scale measuring range up to 1.9 × 108 cm-2 s-1, with relative error below 6.1%. The DNFM has been verified to provide a high temporal sensitivity at 10 ms time intervals on a single fission chamber on HL-2A. Contributed paper, published as part of the Proceedings of the 3rd Domestic Electromagnetic Plasma Diagnostics Workshop, September 2016, Hefei, China.

  19. Spaceborne Hybrid Quad-Pol SAR Range Ambiguity Analysis and Simulations

    NASA Astrophysics Data System (ADS)

    Yang, Shilin; Li, Yang; Zhang, Jingjing; Hong, Wen

    2014-11-01

    The higher levels of range ambiguities in the cross-polarized measurement channels are the primary limitations for the matched quad-pol (e.g., HH, VV, VH, and HV) spaceborne synthetic aperture radar (SAR) systems. These ambiguities severely constrain the useful range of incident angles and the swath widths particularly at larger incidence. Adopting hybridpolarimetric architecture can remarkably reduce these ambiguities. In this paper, we analyse and develop the expression of range ambiguity to signal ratio (RASR) in the hybrid-polarimetric architecture. Simulations are made to testify this novel architecture’s advantage in the improvement of range ambiguities. The system operating parameters are derived from NASA’s DESDynl mission. In addition, we used the second order moments of polarimetric covariance matrices to depict target or the environment which are more precisely.

  20. Spaceborne Hybrid Quad-Pol SAR Range Ambiguity Analysis and Simulations

    NASA Astrophysics Data System (ADS)

    Yang, Shilin; Li, Yang; Zhang, Jingjing; Hong, Wen

    2014-11-01

    The higher levels of range ambiguities in the cross- polarized measurement channels are the primary limitations for the matched quad-pol (e.g., HH, VV, VH, and HV) spaceborne synthetic aperture radar (SAR) systems. These ambiguities severely constrain the useful range of incident angles and the swath widths particularly at larger incidence. Adopting hybrid- polarimetric architecture can remarkably reduce these ambiguities. In this paper, we analyse and develop the expression of range ambiguity to signal ratio (RASR) in the hybrid-polarimetric architecture. Simulations are made to testify this novel architecture's advantage in the improvement of range ambiguities. The system operating parameters are derived from NASA's DESDynl mission. In addition, we used the second order moments of polarimetric covariance matrices to depict target or the environment which are more precisely.

  1. The construction of a highly transportable laser ranging station

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The technology of the transportable Laser Ranging Station (TLRS) used in crustal dynamics studies was examined. The TLRS used a single photoelectron beam of limited energy density returned from the Laser Geodynamic Satellite (LAGEOS). Calibration was accomplished by the diversion of a small portion of the outgoing beam attenuated to the same level as the satellite return. Timing for the system was based on a self calibrating Ortec TD811, 100 picosec time interval device. The system was contained in a modified, single chassis recreational vehicle that allowed rapid deployment. The TLRS system was only airmobile on the largest transport aircraft. A 30 cm simple plano/concave transfer lens telescope aided in beam direction. The TLRS system fulfills the need for an accurate method of obtaining range measurements to the LAGEOS satellite incorporated in a mobile, air transportable, and economical configuration.

  2. Sensor Control And Film Annotation For Long Range, Standoff Reconnaissance

    NASA Astrophysics Data System (ADS)

    Schmidt, Thomas G.; Peters, Owen L.; Post, Lawrence H.

    1984-12-01

    This paper describes a Reconnaissance Data Annotation System that incorporates off-the-shelf technology and system designs providing a high degree of adaptability and interoperability to satisfy future reconnaissance data requirements. The history of data annotation for reconnaissance is reviewed in order to provide the base from which future developments can be assessed and technical risks minimized. The system described will accommodate new developments in recording head assemblies and the incorporation of advanced cameras of both the film and electro-optical type. Use of microprocessor control and digital bus inter-face form the central design philosophy. For long range, high altitude, standoff missions, the Data Annotation System computes the projected latitude and longitude of central target position from aircraft position and attitude. This complements the use of longer ranges and high altitudes for reconnaissance missions.

  3. How accurately can the microcanonical ensemble describe small isolated quantum systems?

    NASA Astrophysics Data System (ADS)

    Ikeda, Tatsuhiko N.; Ueda, Masahito

    2015-08-01

    We numerically investigate quantum quenches of a nonintegrable hard-core Bose-Hubbard model to test the accuracy of the microcanonical ensemble in small isolated quantum systems. We show that, in a certain range of system size, the accuracy increases with the dimension of the Hilbert space D as 1 /D . We ascribe this rapid improvement to the absence of correlations between many-body energy eigenstates. Outside of that range, the accuracy is found to scale either as 1 /√{D } or algebraically with the system size.

  4. Ultrasonic Ranging System With Increased Resolution

    NASA Technical Reports Server (NTRS)

    Meyer, William E.; Johnson, William G.

    1987-01-01

    Master-oscillator frequency increased. Ultrasonic range-measuring system with 0.1-in. resolution provides continuous digital display of four distance readings, each updated four times per second. Four rangefinder modules in system are modified versions of rangefinder used for automatic focusing in commercial series of cameras. Ultrasonic pulses emitted by system innocuous to both people and equipment. Provides economical solutions to such distance-measurement problems as posed by boats approaching docks, truck backing toward loading platform, runway-clearance readout for tail of airplane with high angle attack, or burglar alarm.

  5. General Guide for Community College System Physical Planning. 2nd Printing.

    ERIC Educational Resources Information Center

    Mogi, Hitoshi

    Part I describes a general outline for producing long range development plans for the Hawaii Community College System. Long-range planning is defined and discussed in terms of basic elements of academic requirements, quality of campus, space requirements, environmental factors, administrative factors, and adjustment factors of the general plans.…

  6. Visibility Variability at Seattle, WA and Portland, OR : Insights into the Impacts of Runway Visual Range (RVR) Measurements on Aviation Operations.

    DOT National Transportation Integrated Search

    2001-01-14

    The FAA's new generation Runway Visual Range (RVR) : system was first placed into service in 1994 at several : key airports in the United States. During the last three : years, the Volpe National Transportation Systems Center : has monitored RVR data...

  7. 76 FR 72097 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-22

    ... broad range of adverse health effects. These may include damage to the central nervous system...) Meteorology (weather/transport patterns); (6) Geography/topography (mountain ranges or other air basin... to the EPA's Air Quality System (AQS), or otherwise available to the EPA, and meeting the...

  8. FY2009-2034 Unmanned Systems Integrated Roadmap

    DTIC Science & Technology

    2009-04-20

    FY2009–2034 Unmanned Systems Integrated Roadmap Page i Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the...56 A.1.7 XM-156 Class I ...60 A.1.11 Improved Gnat Extended Range ( I -Gnat-ER) “Warrior Alpha” / Extended Range/Multi- purpose (ER/MP) Block

  9. Using the Global Positioning System for Earth Orbiter and Deep Space Tracking

    NASA Technical Reports Server (NTRS)

    Lichten, Stephen M.

    1994-01-01

    The Global Positioning System (GPS) can play a major role in supporting orbit and trajectory determination for spacecraft in a wide range of applications, including low-Earth, high-Earth, and even deep space (interplanetary) tracking. This paper summarizes recent results demonstrating these unique and far-ranging applications of GPS.

  10. Development of a Ranging System for the Forward Scattering Meteor Radio Echo Observation Using a GPS-Synchronized Multiple Receiving Stations

    NASA Astrophysics Data System (ADS)

    Usui, T.; Yoshida, H.; Miyamoto, H.; Yaguchi, N.; Terasawa, T.; Yoshikawa, I.

    2012-05-01

    We are developing an instrument for teaching purpose to determine the trajectory of a meteor with the Ham-band Radio Observations(HRO) . In this work, we describe newly developed ranging system with using Frequency Modulated signals and show some results.

  11. 14 CFR 25.677 - Trim systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... clearly visible means to indicate the position of the trim device with respect to the range of adjustment. The indicator must be clearly marked with the range within which it has been demonstrated that takeoff... appropriately balanced and shown to be free from flutter. (d) If an irreversible tab control system is used, the...

  12. Systems and processes for conversion of ethylene feedstocks to hydrocarbon fuels

    DOEpatents

    Lilga, Michael A.; Hallen, Richard T.; Albrecht, Karl O.; Cooper, Alan R.; Frye, John G.; Ramasamy, Karthikeyan Kallupalayam

    2018-04-03

    Systems, processes, and catalysts are disclosed for obtaining fuel and fuel blends containing selected ratios of open-chain and closed-chain fuel-range hydrocarbons suitable for production of alternate fuels including gasolines, jet fuels, and diesel fuels. Fuel-range hydrocarbons may be derived from ethylene-containing feedstocks and ethanol-containing feedstocks.

  13. Systems and processes for conversion of ethylene feedstocks to hydrocarbon fuels

    DOEpatents

    Lilga, Michael A.; Hallen, Richard T.; Albrecht, Karl O.; Cooper, Alan R.; Frye, John G.; Ramasamy, Karthikeyan Kallupalayam

    2017-05-30

    Systems, processes, and catalysts are disclosed for obtaining fuel and fuel blends containing selected ratios of open-chain and closed-chain fuel-range hydrocarbons suitable for production of alternate fuels including gasolines, jet fuels, and diesel fuels. Fuel-range hydrocarbons may be derived from ethylene-containing feedstocks and ethanol-containing feedstocks.

  14. Systems and processes for conversion of ethylene feedstocks to hydrocarbon fuels

    DOEpatents

    Lilga, Michael A.; Hallen, Richard T.; Albrecht, Karl O.; Cooper, Alan R.; Frye, John G.; Ramasamy, Karthikeyan Kallupalayam

    2017-09-26

    Systems, processes, and catalysts are disclosed for obtaining fuels and fuel blends containing selected ratios of open-chain and closed-chain fuel-range hydrocarbons suitable for production of alternate fuels including gasolines, jet fuels, and diesel fuels. Fuel-range hydrocarbons may be derived from ethylene-containing feedstocks and ethanol-containing feedstocks.

  15. Ceric and ferrous dosimeters show precision for 50-5000 rad range

    NASA Technical Reports Server (NTRS)

    Frigerio, N. A.; Henry, V. D.

    1968-01-01

    Ammonium thiocyanate, added to the usual ferrous sulfate dosimeter solution, yielded a very stable, precise and temperature-independent system eight times as sensitive as the classical Fricke system in the 50 to 5000 rad range. The ceric dosimeters, promising for use in mixed radiation fields, respond nearly independently of LET.

  16. Global Test Range: Toward Airborne Sensor Webs

    NASA Technical Reports Server (NTRS)

    Mace, Thomas H.; Freudinger, Larry; DelFrate John H.

    2008-01-01

    This viewgraph presentation reviews the planned global sensor network that will monitor the Earth's climate, and resources using airborne sensor systems. The vision is an intelligent, affordable Earth Observation System. Global Test Range is a lab developing trustworthy services for airborne instruments - a specialized Internet Service Provider. There is discussion of several current and planned missions.

  17. Modifications to JLab 12 GeV Refrigerator and Wide Range Mix Mode Performance Testing Results

    NASA Astrophysics Data System (ADS)

    Knudsen, P.; Ganni, V.; Hasan, N.; Dixon, K.; Norton, R.; Creel, J.

    2017-02-01

    Analysis of data obtained during the spring 2013 commissioning of the new 4.5 K refrigeration system at Jefferson Lab (JLab) for the 12 GeV upgrade indicated a wide capacity range with good efficiency and minimal operator interaction. Testing also showed that the refrigerator required higher liquid nitrogen (LN) consumption for its pre-cooler than anticipated by the design. This does not affect the capacity of the refrigerator, but it does result in an increased LN utility cost. During the summer of 2015 the modifications were implemented by the cold box manufacturer, according to a design similar to the JLab 12 GeV cold box specification. Subsequently, JLab recommissioned the cold box and performed extensive performance testing, ranging from 20% to 100% of the design maximum capacity, and in various modes of operation, ranging from pure refrigeration, pure liquefaction, half-and-half mix mode and at selected design modes using the Floating Pressure - Ganni Cycle. The testing demonstrated that the refrigerator system has a good and fairly constant performance over a wide capacity range and different modes of operation. It also demonstrated the modifications resulted in a LN consumption that met the design for the pure refrigeration mode (which is the most demanding) and was lower than the design for the nominal and maximum capacity modes. In addition, a pulsed-load test, similar to what is expected for cryogenic systems supporting fusion experiments, was conducted to observe the response using the Floating Pressure - Ganni Cycle, which was stable and robust. This paper will discuss the results and analysis of this testing pertaining to the LN consumption, the system efficiency over a wide range of capacity and different modes and the behaviour of the system to a pulsed load.

  18. Imaging laser radar for high-speed monitoring of the environment

    NASA Astrophysics Data System (ADS)

    Froehlich, Christoph; Mettenleiter, M.; Haertl, F.

    1998-01-01

    In order to establish mobile robot operations and to realize survey and inspection tasks, robust and precise measurements of the geometry of the 3D environment is the basis sensor technology. For visual inspection, surface classification, and documentation purposes, however, additional information concerning reflectance of measured objects is necessary. High-speed acquisition of both geometric and visual information is achieved by means of an active laser radar, supporting consistent range and reflectance images. The laser radar developed at Zoller + Froehlich (ZF) is an optical-wavelength system measuring the range between sensor and target surface as well as the reflectance of the target surface, which corresponds to the magnitude of the back scattered laser energy. In contrast to other range sensing devices, the ZF system is designed for high-speed and high- performance operation in real indoor and outdoor environments, emitting a minimum of near-IR laser energy. It integrates a single-point laser measurement system and a mechanical deflection system for 3D environmental measurements. This paper reports details of the laser radar which is designed to cover requirements with medium range applications. It outlines the performance requirements and introduces the two-frequency phase-shift measurement principle. The hardware design of the single-point laser measurement system, including the main modulates, such as the laser head, the high frequency unit and the signal processing unit are discussed in detail. The paper focuses on performance data of the laser radar, including noise, drift over time, precision, and accuracy with measurements. It discusses the influences of ambient light, surface material of the target, and ambient temperature for range accuracy and range precision. Furthermore, experimental results from inspection of tunnels, buildings, monuments and industrial environments are presented. The paper concludes by summarizing results and gives a short outlook to future work.

  19. ManPortable and UGV LIVAR: advances in sensor suite integration bring improvements to target observation and identification for the electronic battlefield

    NASA Astrophysics Data System (ADS)

    Lynam, Jeff R.

    2001-09-01

    A more highly integrated, electro-optical sensor suite using Laser Illuminated Viewing and Ranging (LIVAR) techniques is being developed under the Army Advanced Concept Technology- II (ACT-II) program for enhanced manportable target surveillance and identification. The ManPortable LIVAR system currently in development employs a wide-array of sensor technologies that provides the foot-bound soldier and UGV significant advantages and capabilities in lightweight, fieldable, target location, ranging and imaging systems. The unit incorporates a wide field-of-view, 5DEG x 3DEG, uncooled LWIR passive sensor for primary target location. Laser range finding and active illumination is done with a triggered, flash-lamp pumped, eyesafe micro-laser operating in the 1.5 micron region, and is used in conjunction with a range-gated, electron-bombarded CCD digital camera to then image the target objective in a more- narrow, 0.3$DEG, field-of-view. Target range determination is acquired using the integrated LRF and a target position is calculated using data from other onboard devices providing GPS coordinates, tilt, bank and corrected magnetic azimuth. Range gate timing and coordinated receiver optics focus control allow for target imaging operations to be optimized. The onboard control electronics provide power efficient, system operations for extended field use periods from the internal, rechargeable battery packs. Image data storage, transmission, and processing performance capabilities are also being incorporated to provide the best all-around support, for the electronic battlefield, in this type of system. The paper will describe flash laser illumination technology, EBCCD camera technology with flash laser detection system, and image resolution improvement through frame averaging.

  20. Automating Mid- and Long-Range Scheduling for the NASA Deep Space Network

    NASA Technical Reports Server (NTRS)

    Johnston, Mark D.; Tran, Daniel

    2012-01-01

    NASA has recently deployed a new mid-range scheduling system for the antennas of the Deep Space Network (DSN), called Service Scheduling Software, or S(sup 3). This system was designed and deployed as a modern web application containing a central scheduling database integrated with a collaborative environment, exploiting the same technologies as social web applications but applied to a space operations context. This is highly relevant to the DSN domain since the network schedule of operations is developed in a peer-to-peer negotiation process among all users of the DSN. These users represent not only NASA's deep space missions, but also international partners and ground-based science and calibration users. The initial implementation of S(sup 3) is complete and the system has been operational since July 2011. This paper describes some key aspects of the S(sup 3) system and on the challenges of modeling complex scheduling requirements and the ongoing extension of S(sup 3) to encompass long-range planning, downtime analysis, and forecasting, as the next step in developing a single integrated DSN scheduling tool suite to cover all time ranges.

  1. Observation of prethermalization in long-range interacting spin chains

    PubMed Central

    Neyenhuis, Brian; Zhang, Jiehang; Hess, Paul W.; Smith, Jacob; Lee, Aaron C.; Richerme, Phil; Gong, Zhe-Xuan; Gorshkov, Alexey V.; Monroe, Christopher

    2017-01-01

    Although statistical mechanics describes thermal equilibrium states, these states may or may not emerge dynamically for a subsystem of an isolated quantum many-body system. For instance, quantum systems that are near-integrable usually fail to thermalize in an experimentally realistic time scale, and instead relax to quasi-stationary prethermal states that can be described by statistical mechanics, when approximately conserved quantities are included in a generalized Gibbs ensemble (GGE). We experimentally study the relaxation dynamics of a chain of up to 22 spins evolving under a long-range transverse-field Ising Hamiltonian following a sudden quench. For sufficiently long-range interactions, the system relaxes to a new type of prethermal state that retains a strong memory of the initial conditions. However, the prethermal state in this case cannot be described by a standard GGE; it rather arises from an emergent double-well potential felt by the spin excitations. This result shows that prethermalization occurs in a broader context than previously thought, and reveals new challenges for a generic understanding of the thermalization of quantum systems, particularly in the presence of long-range interactions. PMID:28875166

  2. Vortex-Induced Vibrations of a Flexibly-Mounted Cyber-Physical Rectangular Plate

    NASA Astrophysics Data System (ADS)

    Onoue, Kyohei; Strom, Benjamin; Song, Arnold; Breuer, Kenneth

    2013-11-01

    We have developed a cyber-physical system to explore the vortex-induced vibration (VIV) behavior of a flat plate mounted on a virtual spring damper support. The plate is allowed to oscillate about its mid-chord and the measured angular position, velocity, and torque are used as inputs to a feedback control system that provides a restoring torque and can simulate a wide range of structural dynamic behavior. A series of experiments were carried out using different sized plates, and over a range of freestream velocities, equilibrium angles of attack, and simulated stiffness and damping. We observe a synchronization phenomenon over a wide range of parameter space, wherein the plate oscillates at moderate to large amplitude with a frequency dictated by the natural structural frequency of the system. Additionally, the existence of bistable states is reflected in the hysteretic response of the system. The cyber-physical damping extracts energy from the flow and the efficiency of this harvesting mechanism is characterized over a range of dimensionless stiffness and damping parameters. This research is funded by the Air Force Office of Scientific Research (AFOSR).

  3. Satellite Emission Range Inferred Earth Survey (SERIES) project

    NASA Technical Reports Server (NTRS)

    Buennagel, L. A.; Macdoran, P. F.; Neilan, R. E.; Spitzmesser, D. J.; Young, L. E.

    1984-01-01

    The Global Positioning System (GPS) was developed by the Department of Defense primarily for navigation use by the United States Armed Forces. The system will consist of a constellation of 18 operational Navigation Satellite Timing and Ranging (NAVSTAR) satellites by the late 1980's. During the last four years, the Satellite Emission Range Inferred Earth Surveying (SERIES) team at the Jet Propulsion Laboratory (JPL) has developed a novel receiver which is the heart of the SERIES geodetic system designed to use signals broadcast from the GPS. This receiver does not require knowledge of the exact code sequence being transmitted. In addition, when two SERIES receivers are used differentially to determine a baseline, few cm accuracies can be obtained. The initial engineering test phase has been completed for the SERIES Project. Baseline lengths, ranging from 150 meters to 171 kilometers, have been measured with 0.3 cm to 7 cm accuracies. This technology, which is sponsored by the NASA Geodynamics Program, has been developed at JPL to meet the challenge for high precision, cost-effective geodesy, and to complement the mobile Very Long Baseline Interferometry (VLBI) system for Earth surveying.

  4. Estimating the HVAC energy consumption of plug-in electric vehicles

    NASA Astrophysics Data System (ADS)

    Kambly, Kiran R.; Bradley, Thomas H.

    2014-08-01

    Plug in electric vehicles are vehicles that use energy from the electric grid to provide tractive and accessory power to the vehicle. Due to the limited specific energy of energy storage systems, the energy requirements of heating, ventilation, and air conditioning (HVAC) systems for cabin conditioning can significantly reduce their range between charges. Factors such as local ambient temperature, local solar radiation, local humidity, length of the trip and thermal soak have been identified as primary drivers of cabin conditioning loads and therefore of vehicle range. The objective of this paper is to develop a detailed systems-level approach to connect HVAC technologies and usage conditions to consumer-centric metrics of vehicle performance including energy consumption and range. This includes consideration of stochastic and transient inputs to the HVAC energy consumption model including local weather, solar loads, driving behavior, charging behavior, and regional passenger fleet population. The resulting engineering toolset is used to determine the summation of and geographical distribution of energy consumption by HVAC systems in electric vehicles, and to identify regions of US where the distributions of electric vehicle range are particularly sensitive to climate.

  5. Long range guided wave defect monitoring in rail track

    NASA Astrophysics Data System (ADS)

    Loveday, Philip W.; Long, Craig S.

    2014-02-01

    A guided wave ultrasound system was previously developed for monitoring rail track used on heavy duty freight lines. This system operates by transmitting guided waves between permanently installed transmit and receive transducers spaced approximately 1km apart. The system has been proven to reliably detect rail breaks without false alarms. While cracks are sometimes detected there is a trade - off between detecting cracks and the possibility of false alarms. Adding a pulse-echo mode of operation to the system could provide increased functionality by detecting, locating and possibly monitoring cracks. This would require an array of transducers to control the direction and mode of propagation and it would be necessary to detect cracks up to a range of approximately 500 m in either direction along the rail. A four transducer array was designed and full matrix capture was used for field measurements. Post processing of the signals showed that a thermite weld could be detected at a range of 790m from the transducer array. It was concluded that the required range can be achieved in new rail while it would be extremely difficult in very old rail.

  6. Which functionalities are available in the electronic health record systems used by French general practitioners? An assessment study of 15 systems.

    PubMed

    Darmon, David; Sauvant, Rémy; Staccini, Pascal; Letrilliart, Laurent

    2014-01-01

    Whereas an unprecedented effort is currently under way worldwide for the implementation of electronic health record (EHR) systems, their capabilities are poorly understood, especially in primary care. The objective of this study was to assess the main functionalities of the EHR systems used in French general practices. Among the 20 EHR systems marketed in France, we assessed the 15 systems used by more than 1500 general practitioners in the Provence-Alpes-Côte d'Azur region in the southeast part of France. Each EHR system was assessed in a general practice office, using two clinical vignettes describing virtual patient consultations. The evaluation criteria were derived from the EuroRec requirements for EHR system quality. The assessment scale included 37 criteria grouped into three sets: background data, consultation data, and exchange functionalities. The scoring system used, totalling 64 points, was based on the validation of the criteria and was adjusted based on the possibility of standardising the data. A high score indicated a good EHR system quality. The median global score was 32 points out of a possible 64 (range: 20-39). The median score was 12 points out of 22 (range: 6-15) for the background data set, 16 points out of 32 (range: 9-22) for the consultation data set, and four points out of 10 (range: 0-6) for the exchange functionalities. No association was found between the number of users and the assessment score of the EHR systems (p=0.79). One third of the EHR systems lacked a problem list and only one of them supported the episode of care. Functionalities noticeably vary among the EHR systems currently used in French primary care. Whereas these systems are globally very focused on drug prescriptions, several core functionalities are frequently lacking. They are also poorly interoperable for healthcare professionals and patients. Further research is necessary to assess their actual use. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Survival and growth of newly transformed Lampsilis cardium and Lampsilis siliquoidea in a flow-through, continuous feeding test system

    USGS Publications Warehouse

    Meinertz, Jeffery R.; Schreier, Theresa M.; Hess, Karina R.; Bartsch, Michelle

    2011-01-01

    A test system was evaluated for assessing chronic toxicity of waterborne chemicals with early life stage mussels. To determine if the test system could result in ≥80% survival in a control (unexposed) group, fat mucket mussels (Lampsilis siliquoidea Barnes, 1823) and plain pocketbook mussels (L. cardium Rafinesque, 1820) 1 day post transformation were stocked into test chambers (250 mL beakers, water volume, 200 mL, 21 °C, 40 mussels of 1 species per chamber) within a test system constructed for conducting chronic, continuous exposure, flow-through toxicity tests. The test system contained 60 chambers containing silica sand, 30 chambers with L. siliquoidea, and 30 with L. cardium. Each chamber in the continuous feeding system received 1 of 6 food types prepared with concentrated algal products. After 28 days, mussels were harvested from chambers to assess survival and growth. For L. siliquoidea, mean survival ranged from 34 to 80% and mean shell length ranged from 464 to 643 µm. For L. cardium, mean survival ranged from 12 to 66% and mean shell length ranged from 437 to 612 µm. The maximum mean growth rate for L. siliquoidea was 12.7 µm/d and for L. cardium was 11.8 µm/d. When offered a continuous diet of Nannochloropsis, Tetraselmis, and Chlorella for 28 days in the test system, the survival of 1 day post transformation L. siliquoidea was 80%. The test system can be easily enhanced with a pumping system continuously delivering test chemical to the test system's flow stream allowing for chronic toxicity tests with 1 day post transformation mussels.

  8. Toward the Application of the Maximum Entropy Production Principle to a Broader Range of Far From Equilibrium Dissipative Systems

    NASA Astrophysics Data System (ADS)

    Lineweaver, C. H.

    2005-12-01

    The principle of Maximum Entropy Production (MEP) is being usefully applied to a wide range of non-equilibrium processes including flows in planetary atmospheres and the bioenergetics of photosynthesis. Our goal of applying the principle of maximum entropy production to an even wider range of Far From Equilibrium Dissipative Systems (FFEDS) depends on the reproducibility of the evolution of the system from macro-state A to macro-state B. In an attempt to apply the principle of MEP to astronomical and cosmological structures, we investigate the problematic relationship between gravity and entropy. In the context of open and non-equilibrium systems, we use a generalization of the Gibbs free energy to include the sources of free energy extracted by non-living FFEDS such as hurricanes and convection cells. Redox potential gradients and thermal and pressure gradients provide the free energy for a broad range of FFEDS, both living and non-living. However, these gradients have to be within certain ranges. If the gradients are too weak, FFEDS do not appear. If the gradients are too strong FFEDS disappear. Living and non-living FFEDS often have different source gradients (redox potential gradients vs thermal and pressure gradients) and when they share the same gradient, they exploit different ranges of the gradient. In a preliminary attempt to distinguish living from non-living FFEDS, we investigate the parameter space of: type of gradient and steepness of gradient.

  9. How different is cancer control across Canada? Comparing performance indicators for prevention, screening, diagnosis, and treatment.

    PubMed

    Rahal, R; Chadder, J; DeCaria, K; Lockwood, G; Bryant, H

    2017-04-01

    Meaningful performance measures are an important part of the toolkit for health system improvement. The Canadian Partnership Against Cancer has been reporting on pan-Canadian cancer system performance indicators since 2009-work that has led to the availability of standardized measures that can help to shed light on the extent of variation and opportunities for quality improvement across the country. Those measures include a core set of system indicators ranging from prevention and screening, through diagnosis and treatment, to survivorship and end-of-life care. Key indicators were calculated and graphed, showing the range from worst to best result for the provinces and territories included in the data. There were often significant differences in cancer system performance between provinces and territories. For example, smoking prevalence rates ranged from 14% to 62%. The 90th percentile wait times from an abnormal breast screen to resolution (without biopsy) ranged from 4 weeks to 8 weeks. The percentage of breast cancer resections that used breast-conserving surgery rather than mastectomy ranged from 38% to 75%. Clinical trial participation rates for adults ranged from 0.2% to 6.6%. Variations in performance indicators between Canadian jurisdictions suggest potential differences in the planning and delivery of cancer control services and in clinical practice patterns and patient outcomes. Understanding sources of variation can help to identify opportunities for improvements in the quality and outcomes of cancer control service delivery in each province and territory.

  10. "Calibration" system for spectral measurements and its experimental results

    NASA Astrophysics Data System (ADS)

    Bruchkouskaya, Sviatlana I.; Katkovsky, Leonid V.; Belyaev, Boris I.; Malyshev, Vladislav B.

    2017-04-01

    "Calibration" system has been developed at A. N. Sevchenko Research Institute of Applied Physical Problems of the Belarusian State University. It was designed for measuring the characteristics of spectral reflectance of all types of natural surfaces (test sites) in ground conditions or on board of aircraft carriers and has the following components: - Photospectroradiometr (PhSR) of high resolution with a range of 400-900 nm, equipped with a digital time-lapse video system; - Two-channel modular spectroradiometer (TMS) with a range of 400-900 nm, designed for simultaneous measurements of reflected light brightness of the underlying surface and the incident radiation from the upper hemisphere; - Two portable spectroradiometers (PSR-700 and PSR-1300) with a spectral range 800-1500 nm; 1200-2500 nm; - Scanning solar spectropolarimeter (SSP-600) with a range of 350-950 nm for measurements of direct sunlight and scattered by the atmosphere at different angles; "Calibration" system provides spectral resolution of 5.2 nm in a range of 400-900 nm, 10 nm in a range of 800-1500 nm and 15 nm in a range of 1200-2500 nm. Measurements of the optical characteristics of solar radiation (for determining parameters of the atmosphere) and that of underlying surface are synchronous. There is also a set of special nozzles for measurements of spectral brightness coefficients, polarization characteristics and spectral albedo. Spectra and images are geotagged to the navigation data (time, GPS). For the measurements of spectral reflection dependencies within "Monitoring-SG" framework expeditions to the Kuril Islands, Kursk aerospace test site and Kamchatka Peninsula were conducted in 2015 and 2016. The spectra of different underlying surfaces have been obtained: soils, plants and water objects, sedimentary and volcanic rocks. These surveys are a valuable material for further researches and selection of test facilities for flight calibration of space imaging systems. Information obtained will be also included in a database of spectral samples created in the Institute of Geography of Russian Academy of Sciences.

  11. Thiol-vinyl systems as shape memory polymers and novel two-stage reactive polymer systems

    NASA Astrophysics Data System (ADS)

    Nair, Devatha P.

    2011-12-01

    The focus of this research was to formulate, characterize and tailor the reaction methodologies and material properties of thiol-vinyl systems to develop novel polymer platforms for a range of engineering applications. Thiol-ene photopolymers were demonstrated to exhibit several advantageous characteristics for shape memory polymer systems for a range of biomedical applications. The thiol-ene shape memory polymer systems were tough and flexible as compared to the acrylic control systems with glass transition temperatures between 30 and 40 °C; ideal for actuation at body temperature. The thiol-ene polymers also exhibited excellent shape fixity and a rapid and distinct shape memory actuation response along with free strain recoveries of greater than 96% and constrained stress recoveries of 100%. Additionally, two-stage reactive thiol-acrylate systems were engineered as a polymer platform technology enabling two independent sets of polymer processing and material properties. There are distinct advantages to designing polymer systems that afford two distinct sets of material properties -- an intermediate polymer that would enable optimum handling and processing of the material (stage 1), while maintaining the ability to tune in different, final properties that enable the optimal functioning of the polymeric material (stage 2). To demonstrate the range of applicability of the two-stage reactive systems, three specific applications were demonstrated; shape memory polymers, lithographic impression materials, and optical materials. The thiol-acrylate reactions exhibit a wide range of application versatility due to the range of available thiol and acrylate monomers as well as reaction mechanisms such as Michael Addition reactions and free radical polymerizations. By designing a series of non-stoichiometeric thiol-acrylate systems, a polymer network is initially formed via a base catalyzed 'click' Michael addition reaction. This self-limiting reaction results in a Stage 1 polymer with excess acrylic functional groups within the network. At a later point in time, the photoinitiated, free radical polymerization of the excess acrylic functional groups results in a highly crosslinked, robust material system. By varying the monomers within the system as well as the stoichiometery of thiol to acrylate functional groups, the ability of the two-stage reactive systems to encompass a wide range of properties at the end of both the stage 1 and stage 2 polymerizations was demonstrated. The thiol-acrylate networks exhibited intermediate Stage 1 rubbery moduli and glass transition temperatures that range from 0.5 MPa and -10 ºC to 22 MPa and 22 ºC respectively. The same polymer networks can then attain glass transition temperatures that range from 5 ºC to 195 ºC and rubbery moduli of up to 200 MPa after the subsequent photocure stage. Two-stage reactive polymer composite systems were also formulated and characterized for thermomechanical and mechanical properties. Thermomechanical analysis showed that the fillers resulted in a significant increase in the modulus at both stage 1 and stage 2 polymerizations without a significant change in the glass transition temperatures (Tg). The two-stage reactive matrix composite formed with a hexafunctional acrylate matrix and 20 volume % silica particles showed a 125% increase in stage 1 modulus and 101% increase in stage 2 modulus, when compared with the modulus of the neat matrix. Finally, the two-stage reactive polymeric devices were formulated and designed as orthopedic suture anchors for arthroscopic surgeries and mechanically characterized. The Stage 1 device was designed to exhibit properties ideal for arthroscopic delivery and device placement with glass transition temperatures 25 -- 30 °C and rubbery moduli ˜ 95 MPa. The subsequent photopolymerization generated Stage 2 polymers designed to match the local bone environment with moduli ranging up to 2 GPa. Additionally, pull-out strengths of 140 N were demonstrated and are equivalent to the pull-strengths achieved by other commercially available suture anchors.

  12. Direct-path acoustic ranging across the Japan Trench axis, Adjacent to the Large Shallow Thrusting in the 2011 Tohoku-Oki earthquake

    NASA Astrophysics Data System (ADS)

    Osada, Y.; Kido, M.; Ito, Y.; Iinuma, T.; Fujimoto, H.; Hino, R.

    2014-12-01

    Seafloor geodetic data, i.e. GPS/acoustic measurement and continuous seafloor pressure monitoring, brought important evidences showing that the 2011 Tohoku-oki earthquake (Mw 9.0) caused huge (> 50 m) coseismic slip near the Japan Trench. The postseismic behavior of the large slipped area is required to clarify to understand why large amount seismic slip could occur there. We started making direct-path acoustic ranging across the trench axis to reveal the convergence rate between the subducting Pacific and overriding continental plates. We expect the change of the baseline length across the trench axis, the plate boundary, reflects the slip rate at the shallow megathrust, which is difficult to estimate only from other geodetic observations largely affected by intraplate deformation caused by the postseismic viscoelastic relaxation process.  To this end, we developed an ultra-deep seafloor acoustic ranging system. Our previous ranging systems have been designed to measure baseline length ~ 1 km and to be deployed up to 7,000 m water-depth (Osada et al., 2008, 2012). In order to realize the measurement across the Japan Trench, we improved this system to enhance range of acoustic ranging as well as operational depth of instruments. The improved system was designed to allow acoustic ranging up to 3 km and to be durable under the high-pressure equivalent to water depth of 9,000 m. In May 2013, we carried out a test deployment of the new ranging system. The system is composed of three seafloor instruments equipped with precision transponder (PXPs). Two of the PXPs were set on the landward slope of the Japan Trench, where large coseismic slip happened in 2011. Another PXP was deployed on the seaward side of the trench so that the baseline change associated with the slip on the plate boundary fault, if any, can be detected. Continuous records of baseline lengths were successfully obtained for four months. The repeatability of the distance measurements was about 20 mm for each of the two baselines. Although the duration of the observation was not long enough to estimate precise rate of baseline length changes, it is unlikely that the shortening rates of the baseline lengths exceed the rate of plate convergence (~ 8 cm/a). The results do not support occurrence of evident afterslip along the shallow plate boundary fault in 2013.

  13. Design considerations and validation of the MSTAR absolute metrology system

    NASA Astrophysics Data System (ADS)

    Peters, Robert D.; Lay, Oliver P.; Dubovitsky, Serge; Burger, Johan; Jeganathan, Muthu

    2004-08-01

    Absolute metrology measures the actual distance between two optical fiducials. A number of methods have been employed, including pulsed time-of-flight, intensity-modulated optical beam, and two-color interferometry. The rms accuracy is currently limited to ~5 microns. Resolving the integer number of wavelengths requires a 1-sigma range accuracy of ~0.1 microns. Closing this gap has a large pay-off: the range (length measurement) accuracy can be increased substantially using the unambiguous optical phase. The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. In this paper, we present recent experiments that use dispersed white light interferometry to independently validate the zero-point of the system. We also describe progress towards reducing the size of optics, and stabilizing the laser wavelength for operation over larger target ranges. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications.

  14. Development of the European Small Geostationary Satellite SGEO

    NASA Astrophysics Data System (ADS)

    Lübberstedt, H.; Schneider, A.; Schuff, H.; Miesner, Th.; Winkler, A.

    2008-08-01

    The SGEO product portfolio, ranging from Satellite platform delivery up to in-orbit delivery of a turnkey system including satellite and ground control station, is designed for applications ranging from TV Broadcast to multimedia applications, Internet access, mobile or fixed services in a wide range of frequency bands. Furthermore, Data Relay missions such as the European Data Relay Satellite (EDRS) as well as other institutional missions are targeted. Key design features of the SGEO platform are high flexibility and modularity in order to accommodate a very wide range of future missions, a short development time below two years and the objective to build the system based on ITAR free subsystems and components. The system will provide a long lifetime of up to 15 years in orbit operations with high reliability. SGEO is the first European satellite to perform all orbit control tasks solely by electrical propulsion (EP). This design provides high mass efficiency and the capability for direct injection into geostationary orbit without chemical propulsion (CP). Optionally, an Apogee Engine Module based on CP will provide the perigee raising manoeuvres in case of a launch into geostationary transfer orbit (GTO). This approach allows an ideal choice out of a wide range of launcher candidates in dependence of the required payload capacity. SGEO will offer to the market a versatile and high performance satellite system with low investment risk for the customer and a short development time. This paper provides an overview of the SGEO system key features and the current status of the SGEO programme.

  15. Self-contained eye-safe laser radar using an erbium-doped fiber laser

    NASA Astrophysics Data System (ADS)

    Driscoll, Thomas A.; Radecki, Dan J.; Tindal, Nan E.; Corriveau, John P.; Denman, Richard

    2003-07-01

    An Eye-safe Laser Radar has been developed under White Sands Missile Range sponsorship. The SEAL system, the Self-contained Eyesafe Autonomous Laser system, is designed to measure target position within a 0.5 meter box. Targets are augmented with Scotchlite for ranging out to 6 km and augmented with a retroreflector for targets out to 20 km. The data latency is less than 1.5 ms, and the position update rate is 1 kHz. The system is air-cooled, contained in a single 200-lb, 6-cubic-foot box, and uses less than 600 watts of prime power. The angle-angle-range data will be used to measure target dynamics and to control a tracking mount. The optical system is built around a diode-pumped, erbium-doped fiber laser rated at 1.5 watts average power at 10 kHz repetition rate with 25 nsec pulse duration. An 8 inch-diameter, F/2.84 telescope is relayed to a quadrant detector at F/0.85 giving a 5 mrad field of view. Two detectors have been evaluated, a Germanium PIN diode and an Intevac TE-IPD. The receiver electronics uses a DSP network of 6 SHARC processors to implement ranging and angle error algorithms along with an Optical AGC, including beam divergence/FOV control loops.Laboratory measurements of the laser characteristics, and system range and angle accuracies will be compared to simulations. Field measurements against actual targets will be presented.

  16. Microprocessor realizations of range rate filters

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The performance of five digital range rate filters is evaluated. A range rate filter receives an input of range data from a radar unit and produces an output of smoothed range data and its estimated derivative range rate. The filters are compared through simulation on an IBM 370. Two of the filter designs are implemented on a 6800 microprocessor-based system. Comparisons are made on the bases of noise variance reduction ratios and convergence times of the filters in response to simulated range signals.

  17. Stochastic performance modeling and evaluation of obstacle detectability with imaging range sensors

    NASA Technical Reports Server (NTRS)

    Matthies, Larry; Grandjean, Pierrick

    1993-01-01

    Statistical modeling and evaluation of the performance of obstacle detection systems for Unmanned Ground Vehicles (UGVs) is essential for the design, evaluation, and comparison of sensor systems. In this report, we address this issue for imaging range sensors by dividing the evaluation problem into two levels: quality of the range data itself and quality of the obstacle detection algorithms applied to the range data. We review existing models of the quality of range data from stereo vision and AM-CW LADAR, then use these to derive a new model for the quality of a simple obstacle detection algorithm. This model predicts the probability of detecting obstacles and the probability of false alarms, as a function of the size and distance of the obstacle, the resolution of the sensor, and the level of noise in the range data. We evaluate these models experimentally using range data from stereo image pairs of a gravel road with known obstacles at several distances. The results show that the approach is a promising tool for predicting and evaluating the performance of obstacle detection with imaging range sensors.

  18. Evolution of density-dependent movement during experimental range expansions.

    PubMed

    Fronhofer, E A; Gut, S; Altermatt, F

    2017-12-01

    Range expansions and biological invasions are prime examples of transient processes that are likely impacted by rapid evolutionary changes. As a spatial process, range expansions are driven by dispersal and movement behaviour. Although it is widely accepted that dispersal and movement may be context-dependent, for instance density-dependent, and best represented by reaction norms, the evolution of density-dependent movement during range expansions has received little experimental attention. We therefore tested current theory predicting the evolution of increased movement at low densities at range margins using highly replicated and controlled range expansion experiments across multiple genotypes of the protist model system Tetrahymena thermophila. Although rare, we found evolutionary changes during range expansions even in the absence of initial standing genetic variation. Range expansions led to the evolution of negatively density-dependent movement at range margins. In addition, we report the evolution of increased intrastrain competitive ability and concurrently decreased population growth rates in range cores. Our findings highlight the importance of understanding movement and dispersal as evolving reaction norms and plastic life-history traits of central relevance for range expansions, biological invasions and the dynamics of spatially structured systems in general. © 2017 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2017 European Society For Evolutionary Biology.

  19. Improved proton CT imaging using a bismuth germanium oxide scintillator.

    PubMed

    Tanaka, Sodai; Nishio, Teiji; Tsuneda, Masato; Matsushita, Keiichiro; Kabuki, Shigeto; Uesaka, Mitsuru

    2018-02-02

    Range uncertainty is among the most formidable challenges associated with the treatment planning of proton therapy. Proton imaging, which includes proton radiography and proton computed tomography (pCT), is a useful verification tool. We have developed a pCT detection system that uses a thick bismuth germanium oxide (BGO) scintillator and a CCD camera. The current method is based on a previous detection system that used a plastic scintillator, and implements improved image processing techniques. In the new system, the scintillation light intensity is integrated along the proton beam path by the BGO scintillator, and acquired as a two-dimensional distribution with the CCD camera. The range of a penetrating proton is derived from the integrated light intensity using a light-to-range conversion table, and a pCT image can be reconstructed. The proton range in the BGO scintillator is shorter than in the plastic scintillator, so errors due to extended proton ranges can be reduced. To demonstrate the feasibility of the pCT system, an experiment was performed using a 70 MeV proton beam created by the AVF930 cyclotron at the National Institute of Radiological Sciences. The accuracy of the light-to-range conversion table, which is susceptible to errors due to its spatial dependence, was investigated, and the errors in the acquired pixel values were less than 0.5 mm. Images of various materials were acquired, and the pixel-value errors were within 3.1%, which represents an improvement over previous results. We also obtained a pCT image of an edible chicken piece, the first of its kind for a biological material, and internal structures approximately one millimeter in size were clearly observed. This pCT imaging system is fast and simple, and based on these findings, we anticipate that we can acquire 200 MeV pCT images using the BGO scintillator system.

  20. Improved proton CT imaging using a bismuth germanium oxide scintillator

    NASA Astrophysics Data System (ADS)

    Tanaka, Sodai; Nishio, Teiji; Tsuneda, Masato; Matsushita, Keiichiro; Kabuki, Shigeto; Uesaka, Mitsuru

    2018-02-01

    Range uncertainty is among the most formidable challenges associated with the treatment planning of proton therapy. Proton imaging, which includes proton radiography and proton computed tomography (pCT), is a useful verification tool. We have developed a pCT detection system that uses a thick bismuth germanium oxide (BGO) scintillator and a CCD camera. The current method is based on a previous detection system that used a plastic scintillator, and implements improved image processing techniques. In the new system, the scintillation light intensity is integrated along the proton beam path by the BGO scintillator, and acquired as a two-dimensional distribution with the CCD camera. The range of a penetrating proton is derived from the integrated light intensity using a light-to-range conversion table, and a pCT image can be reconstructed. The proton range in the BGO scintillator is shorter than in the plastic scintillator, so errors due to extended proton ranges can be reduced. To demonstrate the feasibility of the pCT system, an experiment was performed using a 70 MeV proton beam created by the AVF930 cyclotron at the National Institute of Radiological Sciences. The accuracy of the light-to-range conversion table, which is susceptible to errors due to its spatial dependence, was investigated, and the errors in the acquired pixel values were less than 0.5 mm. Images of various materials were acquired, and the pixel-value errors were within 3.1%, which represents an improvement over previous results. We also obtained a pCT image of an edible chicken piece, the first of its kind for a biological material, and internal structures approximately one millimeter in size were clearly observed. This pCT imaging system is fast and simple, and based on these findings, we anticipate that we can acquire 200 MeV pCT images using the BGO scintillator system.

Top