Sample records for rapid analysis method

  1. [Development of sample pretreatment techniques-rapid detection coupling methods for food security analysis].

    PubMed

    Huang, Yichun; Ding, Weiwei; Zhang, Zhuomin; Li, Gongke

    2013-07-01

    This paper summarizes the recent developments of the rapid detection methods for food security, such as sensors, optical techniques, portable spectral analysis, enzyme-linked immunosorbent assay, portable gas chromatograph, etc. Additionally, the applications of these rapid detection methods coupled with sample pretreatment techniques in real food security analysis are reviewed. The coupling technique has the potential to provide references to establish the selective, precise and quantitative rapid detection methods in food security analysis.

  2. Optimisation and validation of a rapid and efficient microemulsion liquid chromatographic (MELC) method for the determination of paracetamol (acetaminophen) content in a suppository formulation.

    PubMed

    McEvoy, Eamon; Donegan, Sheila; Power, Joe; Altria, Kevin

    2007-05-09

    A rapid and efficient oil-in-water microemulsion liquid chromatographic method has been optimised and validated for the analysis of paracetamol in a suppository formulation. Excellent linearity, accuracy, precision and assay results were obtained. Lengthy sample pre-treatment/extraction procedures were eliminated due to the solubilising power of the microemulsion and rapid analysis times were achieved. The method was optimised to achieve rapid analysis time and relatively high peak efficiencies. A standard microemulsion composition of 33 g SDS, 66 g butan-1-ol, 8 g n-octane in 1l of 0.05% TFA modified with acetonitrile has been shown to be suitable for the rapid analysis of paracetamol in highly hydrophobic preparations under isocratic conditions. Validated assay results and overall analysis time of the optimised method was compared to British Pharmacopoeia reference methods. Sample preparation and analysis times for the MELC analysis of paracetamol in a suppository were extremely rapid compared to the reference method and similar assay results were achieved. A gradient MELC method using the same microemulsion has been optimised for the resolution of paracetamol and five of its related substances in approximately 7 min.

  3. Rapid Method for Sodium Hydroxide/Sodium Peroxide Fusion ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Plutonium-238 and plutonium-239 in water and air filters Method Selected for: SAM lists this method as a pre-treatment technique supporting analysis of refractory radioisotopic forms of plutonium in drinking water and air filters using the following qualitative techniques: • Rapid methods for acid or fusion digestion • Rapid Radiochemical Method for Plutonium-238 and Plutonium 239/240 in Building Materials for Environmental Remediation Following Radiological Incidents. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  4. Application of Solid Phase Microextraction Coupled with Gas Chromatography/Mass Spectrometry as a Rapid Method for Field Sampling and Analysis of Chemical Warfare Agents and Toxic Industrial Chemicals

    DTIC Science & Technology

    2003-01-01

    PHASE MICROEXTRACTION COUPLED WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY AS A RAPID METHOD FOR FIELD SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS...SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...GAS CHROMATOGRAPHY/MASS SPECTROMETRY AS A RAPID METHOD FOR FIELD SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS

  5. Rapid screening and determination of 11 new psychoactive substances by direct analysis in real time mass spectrometry and liquid chromatography/quadrupole time-of-flight mass spectrometry.

    PubMed

    Nie, Honggang; Li, Xianjiang; Hua, Zhendong; Pan, Wei; Bai, Yanping; Fu, Xiaofang

    2016-08-01

    With the amounts and types of new psychoactive substances (NPSs) increasing rapidly in recent years, an excellent high-throughput method for the analysis of these compounds is urgently needed. In this article, a rapid screening method and a quantitative analysis method for 11 NPSs are described and compared, respectively. A simple direct analysis in real time mass spectrometry (DART-MS) method was developed for the analysis of 11 NPSs including three categories of these substances present on the global market such as four cathinones, one phenylethylamine, and six synthetic cannabinoids. In order to analyze these compounds quantitatively with better accuracy and sensitivity, another rapid analytical method with a low limit of detection (LOD) was also developed using liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry (LC/QTOFMS). The 11 NPSs could be determined within 0.5 min by DART-MS. Furthermore, they could also be separated and determined within 5 min by the LC/QTOFMS method. The two methods both showed good linearity with correlation coefficients (r(2) ) higher than 0.99. The LODs for all these target NPSs by DART-MS and LC/QTOFMS ranged from 5 to 40 ng mL(-1) and 0.1 to 1 ng mL(-1) , respectively. Confiscated samples, named as "music vanilla" and "bath salt", and 11 spiked samples were firstly screened by DART-MS and then determined by LC/QTOFMS. The identification of NPSs in confiscated materials was successfully achieved, and the proposed analytical methodology could offer rapid screening and accurate analysis results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. A Rapid Method for Measuring Strontium-90 Activity in Crops in China

    NASA Astrophysics Data System (ADS)

    Pan, Lingjing Pan; Yu, Guobing; Wen, Deyun; Chen, Zhi; Sheng, Liusi; Liu, Chung-King; Xu, X. George

    2017-09-01

    A rapid method for measuring Sr-90 activity in crop ashes is presented. Liquid scintillation counting, combined with ion exchange columns 4`, 4"(5")-di-t-butylcyclohexane-18-crown-6, is used to determine the activity of Sr-90 in crops. The yields of chemical procedure are quantified using gravimetric analysis. The conventional method that uses ion-exchange resin with HDEHP could not completely remove all the bismuth when comparatively large lead and bismuth exist in the samples. This is overcome by the rapid method. The chemical yield of this method is about 60% and the MDA for Sr-90 is found to be 2:32 Bq/kg. The whole procedure together with using spectrum analysis to determine the activity only takes about one day, which is really a large improvement compared with the conventional method. A modified conventional method is also described here to verify the value of the rapid one. These two methods can meet di_erent needs of daily monitoring and emergency situation.

  7. Rapid self-assembly of DNA on a microfluidic chip

    PubMed Central

    Zheng, Yao; Footz, Tim; Manage, Dammika P; Backhouse, Christopher James

    2005-01-01

    Background DNA self-assembly methods have played a major role in enabling methods for acquiring genetic information without having to resort to sequencing, a relatively slow and costly procedure. However, even self-assembly processes tend to be very slow when they rely upon diffusion on a large scale. Miniaturisation and integration therefore hold the promise of greatly increasing this speed of operation. Results We have developed a rapid method for implementing the self-assembly of DNA within a microfluidic system by electrically extracting the DNA from an environment containing an uncharged denaturant. By controlling the parameters of the electrophoretic extraction and subsequent analysis of the DNA we are able to control when the hybridisation occurs as well as the degree of hybridisation. By avoiding off-chip processing or long thermal treatments we are able to perform this hybridisation rapidly and can perform hybridisation, sizing, heteroduplex analysis and single-stranded conformation analysis within a matter of minutes. The rapidity of this analysis allows the sampling of transient effects that may improve the sensitivity of mutation detection. Conclusions We believe that this method will aid the integration of self-assembly methods upon microfluidic chips. The speed of this analysis also appears to provide information upon the dynamics of the self-assembly process. PMID:15717935

  8. Real-time subsecond voltammetric analysis of Pb in aqueous environmental samples.

    PubMed

    Yang, Yuanyuan; Pathirathna, Pavithra; Siriwardhane, Thushani; McElmurry, Shawn P; Hashemi, Parastoo

    2013-08-06

    Lead (Pb) pollution is an important environmental and public health concern. Rapid Pb transport during stormwater runoff significantly impairs surface water quality. The ability to characterize and model Pb transport during these events is critical to mitigating its impact on the environment. However, Pb analysis is limited by the lack of analytical methods that can afford rapid, sensitive measurements in situ. While electrochemical methods have previously shown promise for rapid Pb analysis, they are currently limited in two ways. First, because of Pb's limited solubility, test solutions that are representative of environmental systems are not typically employed in laboratory characterizations. Second, concerns about traditional Hg electrode toxicity, stability, and low temporal resolution have dampened opportunities for in situ analyses with traditional electrochemical methods. In this paper, we describe two novel methodological advances that bypass these limitations. Using geochemical models, we first create an environmentally relevant test solution that can be used for electrochemical method development and characterization. Second, we develop a fast-scan cyclic voltammetry (FSCV) method for Pb detection on Hg-free carbon fiber microelectrodes. We assess the method's sensitivity and stability, taking into account Pb speciation, and utilize it to characterize rapid Pb fluctuations in real environmental samples. We thus present a novel real-time electrochemical tool for Pb analysis in both model and authentic environmental solutions.

  9. Rapid qualitative and quantitative analysis of proanthocyanidin oligomers and polymers by ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS)

    USDA-ARS?s Scientific Manuscript database

    We developed a rapid method with ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS) for the qualitative and quantitative analysis of plant proanthocyanidins (PAs) directly from crude plant extracts. The method utilizes a range of cone voltages to achieve the depolymeriza...

  10. Application of Solid Phase Microextraction with Gas Chromatography-Mass Spectrometry as a Rapid, Reliable, and Safe Method for Field Sampling and Analysis of Chemical Warfare Agent Precursors

    DTIC Science & Technology

    2005-03-01

    in hair samples with analysis by GC-MS [41,42]. The research discussed here examined a polydimethylsiloxane polymer with 10% activated charcoal (PDMS...Field Sampling and Analysis of Chemical Warfare Agent Precursors” Name of Candidate: LT Douglas Parrish Doctor of Philosophy, Environmental...Microextraction with Gas Chromatography-Mass Spectrometry as a Rapid, Reliable, and Safe Method for Field Sampling and Analysis of Chemical Warfare

  11. Rapid Analysis of Corni fructus Using Paper Spray-Mass Spectrometry.

    PubMed

    Guo, Yuan; Gu, Zhixin; Liu, Xuemei; Liu, Jingjing; Ma, Ming; Chen, Bo; Wang, Liping

    2017-07-01

    Paper spray-mass spectrometry (PS-MS) is a kind of ambient MS technique for the rapid analysis of samples. Corni fructus has been widely used in traditional Chinese compound preparations and healthy food. However, a number of counterfeits of Corni fructus, such as Crataegi fructus, Lycii fructus, and grape skin are illegally sold in crude herb markets. Therefore, the development of a rapid and high-throughput quality evaluation method is important for ensuring the effectiveness and safety of the crude materials of Corni fructus. To develop PS-MS chemical profiles and a semi-quantitative method of Corni fructus for quality assessment and control, and species distinction of Corni fructus. Both positive and negative ion PS-MS chemical profiles were constructed for species distinction. The statistical analysis of the chemical profiles was accomplished by principal component analysis (PCA). Rapid semi-quantitative analysis of loganin and morroniside in the extracts of Corni fructus were accomplished by PS-MS. The profiles of the Corni fructus and Crataegi fructus samples were clearly clustered into two categories. The limit of quantification (LOQ) in the semi-quantitative analysis was 6 μg/mL and 5.6 μg/mL for loganin and morroniside, respectively. PS-MS is a simple, rapid, and high-throughput method for the quality control and species distinction of Corni fructus. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. An optimized rapid bisulfite conversion method with high recovery of cell-free DNA.

    PubMed

    Yi, Shaohua; Long, Fei; Cheng, Juanbo; Huang, Daixin

    2017-12-19

    Methylation analysis of cell-free DNA is a encouraging tool for tumor diagnosis, monitoring and prognosis. Sensitivity of methylation analysis is a very important matter due to the tiny amounts of cell-free DNA available in plasma. Most current methods of DNA methylation analysis are based on the difference of bisulfite-mediated deamination of cytosine between cytosine and 5-methylcytosine. However, the recovery of bisulfite-converted DNA based on current methods is very poor for the methylation analysis of cell-free DNA. We optimized a rapid method for the crucial steps of bisulfite conversion with high recovery of cell-free DNA. A rapid deamination step and alkaline desulfonation was combined with the purification of DNA on a silica column. The conversion efficiency and recovery of bisulfite-treated DNA was investigated by the droplet digital PCR. The optimization of the reaction results in complete cytosine conversion in 30 min at 70 °C and about 65% of recovery of bisulfite-treated cell-free DNA, which is higher than current methods. The method allows high recovery from low levels of bisulfite-treated cell-free DNA, enhancing the analysis sensitivity of methylation detection from cell-free DNA.

  13. Rapid 3-D analysis of rockfalls

    USGS Publications Warehouse

    Stock, Greg M.; Guerin, A.; Avdievitch, Nikita N.; Collins, Brian D.; Jaboyedoff, Michel

    2018-01-01

    Recent fatal and damaging rockfalls in Yosemite National Park indicate the need for rapid response data collection methods to inform public safety and assist with management response. Here we show the use of multiple-platform remote sensing methods to rapidly capture pertinent data needed to inform management and the public following a several large rockfalls from El Capitan cliff in Yosemite Valley, California.

  14. Rapid method for the quantification of hydroquinone concentration: chemiluminescent analysis.

    PubMed

    Chen, Tung-Sheng; Liou, Show-Yih; Kuo, Wei-Wen; Wu, Hsi-Chin; Jong, Gwo-Ping; Wang, Hsueh-Fang; Shen, Chia-Yao; Padma, V Vijaya; Huang, Chih-Yang; Chang, Yen-Lin

    2015-11-01

    Topical hydroquinone serves as a skin whitener and is usually available in cosmetics or on prescription based on the hydroquinone concentration. Quantification of hydroquinone content therefore becomes an important issue in topical agents. High-performance liquid chromatography (HPLC) is the commonest method for determining hydroquinone content in topical agents, but this method is time-consuming and uses many solvents that can become an environmental issue. We report a rapid method for quantifying hydroquinone content by chemiluminescent analysis. Hydroquinone induces the production of hydrogen peroxide in the presence of basic compounds. Hydrogen peroxide induced by hydroquinone oxidized light-emitting materials such as lucigenin, resulted in the production of ultra-weak chemiluminescence that was detected by a chemiluminescence analyzer. The intensity of the chemiluminescence was found to be proportional to the hydroquinone concentration. We suggest that the rapid (measurement time, 60 s) and virtually solvent-free (solvent volume, <2 mL) chemiluminescent method described here for quantifying hydroquinone content may be an alternative to HPLC analysis. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Rapid scanning system for fuel drawers

    DOEpatents

    Caldwell, J.T.; Fehlau, P.E.; France, S.W.

    A nondestructive method for uniquely distinguishing among and quantifying the mass of individual fuel plates in situ in fuel drawers utilized in nuclear reactors is described. The method is both rapid and passive, eliminating the personnel hazard of the commonly used irradiation techniques which require that the analysis be performed in proximity to an intense neutron source such as a reactor. In the present technique, only normally decaying nuclei are observed. This allows the analysis to be performed anywhere. This feature, combined with rapid scanning of a given fuel drawer (in approximately 30 s), and the computer data analysis allows the processing of large numbers of fuel drawers efficiently in the event of a loss alert.

  16. Rapid scanning system for fuel drawers

    DOEpatents

    Caldwell, John T.; Fehlau, Paul E.; France, Stephen W.

    1981-01-01

    A nondestructive method for uniqely distinguishing among and quantifying the mass of individual fuel plates in situ in fuel drawers utilized in nuclear reactors is described. The method is both rapid and passive, eliminating the personnel hazard of the commonly used irradiation techniques which require that the analysis be performed in proximity to an intense neutron source such as a reactor. In the present technique, only normally decaying nuclei are observed. This allows the analysis to be performed anywhere. This feature, combined with rapid scanning of a given fuel drawer (in approximately 30 s), and the computer data analysis allows the processing of large numbers of fuel drawers efficiently in the event of a loss alert.

  17. Romer Labs RapidChek®Listeria monocytogenes Test System for the Detection of L. monocytogenes on Selected Foods and Environmental Surfaces.

    PubMed

    Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T

    2018-04-27

    The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.

  18. Analysis of psilocybin and psilocin in Psilocybe subcubensis Guzmán by ion mobility spectrometry and gas chromatography-mass spectrometry.

    PubMed

    Keller, T; Schneider, A; Regenscheit, P; Dirnhofer, R; Rücker, T; Jaspers, J; Kisser, W

    1999-01-11

    A new method has been developed for the rapid analysis of psilocybin and/or psilocin in fungus material using ion mobility spectrometry. Quantitative analysis was performed by gas chromatography-mass spectrometry after a simple one-step extraction involving homogenization of the dried fruit bodies of fungi in chloroform and derivatization with MSTFA. The proposed methods resulted in rapid procedures useful in analyzing psychotropic fungi for psilocybin and psilocin.

  19. Rapid Method for Sodium Hydroxide Fusion of Asphalt ...

    EPA Pesticide Factsheets

    Technical Brief--Addendum to Selected Analytical Methods (SAM) 2012 Rapid method developed for analysis of Americium-241 (241Am), plutonium-238 (238Pu), plutonium-239 (239Pu), radium-226 (226Ra), strontium-90 (90Sr), uranium-234 (234U), uranium-235 (235U) and uranium-238 (238U) in asphalt roofing material samples

  20. Multiplex titration RT-PCR: rapid determination of gene expression patterns for a large number of genes

    NASA Technical Reports Server (NTRS)

    Nebenfuhr, A.; Lomax, T. L.

    1998-01-01

    We have developed an improved method for determination of gene expression levels with RT-PCR. The procedure is rapid and does not require extensive optimization or densitometric analysis. Since the detection of individual transcripts is PCR-based, small amounts of tissue samples are sufficient for the analysis of expression patterns in large gene families. Using this method, we were able to rapidly screen nine members of the Aux/IAA family of auxin-responsive genes and identify those genes which vary in message abundance in a tissue- and light-specific manner. While not offering the accuracy of conventional semi-quantitative or competitive RT-PCR, our method allows quick screening of large numbers of genes in a wide range of RNA samples with just a thermal cycler and standard gel analysis equipment.

  1. Evaluation of High-Resolution Melting Curve Analysis of Ligation-Mediated Real-Time PCR, a Rapid Method for Epidemiological Typing of ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter Species) Pathogens

    PubMed Central

    Ryberg, Anna; Billström, Hanna; Hällgren, Anita; Nilsson, Lennart E.; Marklund, Britt-Inger; Olsson-Liljequist, Barbro; Schön, Thomas

    2014-01-01

    A single-tube method, ligation-mediated real-time PCR high-resolution melt analysis (LMqPCR HRMA), was modified for the rapid typing of Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp. (ESKAPE) pathogens. A 97% agreement (60/62 isolates) was achieved in comparison to pulsed-field gel electrophoresis (PFGE) results, which indicates that LMqPCR HRMA is a rapid and accurate screening tool for monitoring nosocomial outbreaks. PMID:25232168

  2. Rapid Radiochemical Method for Radium-226 in Building ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Radium-226 in building materials Method Selected for: SAM lists this method for qualitative analysis of radium-226 in concrete or brick building materials Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  3. Rapid Radiochemical Method for Americium-241 in Building ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Americium-241 in building materials Method Selected for: SAM lists this method for qualitative analysis of americium-241 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  4. [Rapid determination of volatile organic compounds in workplace air by protable gas chromatography-mass spectrometer].

    PubMed

    Zhu, H B; Su, C J; Tang, H F; Ruan, Z; Liu, D H; Wang, H; Qian, Y L

    2017-10-20

    Objective: To establish a method for rapid determination of 47 volatile organic compounds in the air of workplace using portable gas chromatography - mass spectrometer(GC - MS). Methods: The mixed standard gas with different concentration levels was made by using the static gas distribution method with the high purity nitrogen as dilution gas. The samples were injected into the GC - MS by a hand - held probe. Retention time and characteristic ion were used for qualitative analysis,and the internal standard method was usd for quantitation. Results: The 47 poisonous substances were separated and determined well. The linear range of this method was 0.2 - 16.0 mg/m(3),and the relative standard deviation of 45 volatile ovganic compounds was 3.8% - 15.8%. The average recovery was 79.3% - 119.0%. Conclusion: The method is simple,accurate,sensitive,has good separation effect,short analysis period, can be used for qualitative and quantitative analysis of volatile organic compounds in the workplace, and also supports the rapid identification and detection of occupational hazards.

  5. Rapid analysis of scattering from periodic dielectric structures using accelerated Cartesian expansions.

    PubMed

    Baczewski, Andrew D; Miller, Nicholas C; Shanker, Balasubramaniam

    2012-04-01

    The analysis of fields in periodic dielectric structures arise in numerous applications of recent interest, ranging from photonic bandgap structures and plasmonically active nanostructures to metamaterials. To achieve an accurate representation of the fields in these structures using numerical methods, dense spatial discretization is required. This, in turn, affects the cost of analysis, particularly for integral-equation-based methods, for which traditional iterative methods require O(N2) operations, N being the number of spatial degrees of freedom. In this paper, we introduce a method for the rapid solution of volumetric electric field integral equations used in the analysis of doubly periodic dielectric structures. The crux of our method is the accelerated Cartesian expansion algorithm, which is used to evaluate the requisite potentials in O(N) cost. Results are provided that corroborate our claims of acceleration without compromising accuracy, as well as the application of our method to a number of compelling photonics applications.

  6. [Techniques for rapid production of monoclonal antibodies for use with antibody technology].

    PubMed

    Kamada, Haruhiko

    2012-01-01

    A monoclonal antibody (Mab), due to its specific binding ability to a target protein, can potentially be one of the most useful tools for the functional analysis of proteins in recent proteomics-based research. However, the production of Mab is a very time-consuming and laborious process (i.e., preparation of recombinant antigens, immunization of animals, preparation of hybridomas), making it the rate-limiting step in using Mabs in high-throughput proteomics research, which heavily relies on comprehensive and rapid methods. Therefore, there is a great demand for new methods to efficiently generate Mabs against a group of proteins identified by proteome analysis. Here, we describe a useful method called "Antibody proteomic technique" for the rapid generations of Mabs to pharmaceutical target, which were identified by proteomic analyses of disease samples (ex. tumor tissue, etc.). We also introduce another method to find profitable targets on vasculature, which is called "Vascular proteomic technique". Our results suggest that this method for the rapid generation of Mabs to proteins may be very useful in proteomics-based research as well as in clinical applications.

  7. Behaviour of levee on softsoil caused by rapid drawdown

    NASA Astrophysics Data System (ADS)

    Upomo, Togani Cahyadi; Effendi, Mahmud Kori; Kusumawardani, Rini

    2018-03-01

    Rapid Drawdown is a condition where the water elevation that has reached the peak suddenly drops. As the water level reaches the peak, hydrostatic pressure helps in the stability of the slope. When water elevation decreases there will be two effects. First, reduced hydrostatic pressure and second, modification of pore water pressure. Rapid draw down usually comon in hydraulic structure such as dam and levee. This study will discuss behaviour of levee on softsoil caused by rapid drawdown. The analysis based on method which developed by US Army Corps Engineer and modified method which developed by Duncan, Wright, dan Wong. Results of analysis show that in drawdown condition, at 1 m drop of water, safety factor obtained based on US Army Corps Engineer method was 1.16 and 0.976 while based on Duncan, Wright, and Wong methods were 1.244 and 1.117. At 0.5 m water level, safety factor based on US Army Corps Engineer method was 1.287 and 1.09 while Duncan, Wright, and Wong were 1.357 and 1.194.

  8. Rapid Radiochemical Method for Total Radiostrontium (Sr-90) ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Beta counting Method Developed for: Strontium-89 and strontium-90 in building materials Method Selected for: SAM lists this method for qualitative analysis of strontium-89 and strontium-90 in concrete or brick building materials Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  9. Comparison of orbital volume obtained by tomography and rapid prototyping.

    PubMed

    Roça, Guilherme Berto; Foggiatto, José Aguiomar; Ono, Maria Cecilia Closs; Ono, Sergio Eiji; da Silva Freitas, Renato

    2013-11-01

    This study aims to compare orbital volume obtained by helical tomography and rapid prototyping. The study sample was composed of 6 helical tomography scans. Eleven healthy orbits were identified to have their volumes measured. The volumetric analysis with the helical tomography utilized the same protocol developed by the Plastic Surgery Unit of the Federal University of Paraná. From the CT images, 11 prototypes were created, and their respective volumes were analyzed in 2 ways: using software by SolidWorks and by direct analysis, when the prototype was filled with saline solution. For statistical analysis, the results of the volumes of the 11 orbits were considered independent. The average orbital volume measurements obtained by the method of Ono et al was 20.51 cm, the average obtained by the SolidWorks program was 20.64 cm, and the average measured using the prototype method was 21.81 cm. The 3 methods demonstrated a strong correlation between the measurements. The right and left orbits of each patient had similar volumes. The tomographic method for the analysis of orbital volume using the Ono protocol yielded consistent values, and by combining this method with rapid prototyping, both reliability validations of results were enhanced.

  10. Rapid structural analysis of nanomaterials in aqueous solutions

    NASA Astrophysics Data System (ADS)

    Ryuzaki, Sou; Tsutsui, Makusu; He, Yuhui; Yokota, Kazumichi; Arima, Akihide; Morikawa, Takanori; Taniguchi, Masateru; Kawai, Tomoji

    2017-04-01

    Rapid structural analysis of nanoscale matter in a liquid environment represents innovative technologies that reveal the identities and functions of biologically important molecules. However, there is currently no method with high spatio-temporal resolution that can scan individual particles in solutions to gain structural information. Here we report the development of a nanopore platform realizing quantitative structural analysis for suspended nanomaterials in solutions with a high z-axis and xy-plane spatial resolution of 35.8 ± 1.1 and 12 nm, respectively. We used a low thickness-to-diameter aspect ratio pore architecture for achieving cross sectional areas of analyte (i.e. tomograms). Combining this with multiphysics simulation methods to translate ionic current data into tomograms, we demonstrated rapid structural analysis of single polystyrene (Pst) beads and single dumbbell-like Pst beads in aqueous solutions.

  11. Comparison of mid-infrared transmission spectroscopy with biochemical methods for the determination of macronutrients in human milk.

    PubMed

    Silvestre, Dolores; Fraga, Miriam; Gormaz, María; Torres, Ester; Vento, Máximo

    2014-07-01

    The variability of human milk (HM) composition renders analysis of its components essential for optimal nutrition of preterm fed either with donor's or own mother's milk. To fulfil this requirement, various analytical instruments have been subjected to scientific and clinical evaluation. The objective of this study was to evaluate the suitability of a rapid method for the analysis of macronutrients in HM as compared with the analytical methods applied by cow's milk industry. Mature milk from 39 donors was analysed using an infrared human milk analyser (HMA) and compared with biochemical reference laboratory methods. The statistical analysis was based on the use of paired data tests. The use of an infrared HMA for the analysis of lipids, proteins and lactose in HM proved satisfactory as regards the rapidity, simplicity and the required sample volume. The instrument afforded good linearity and precision in application to all three nutrients. However, accuracy was not acceptable when compared with the reference methods, with overestimation of the lipid content and underestimation of the amount of proteins and lactose contents. The use of mid-infrared HMA might become the standard for rapid analysis of HM once standardisation and rigorous and systematic calibration is provided. © 2012 John Wiley & Sons Ltd.

  12. Evaluation of high-resolution melting curve analysis of ligation-mediated real-time PCR, a rapid method for epidemiological typing of ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter Species) pathogens.

    PubMed

    Woksepp, Hanna; Ryberg, Anna; Billström, Hanna; Hällgren, Anita; Nilsson, Lennart E; Marklund, Britt-Inger; Olsson-Liljequist, Barbro; Schön, Thomas

    2014-12-01

    A single-tube method, ligation-mediated real-time PCR high-resolution melt analysis (LMqPCR HRMA), was modified for the rapid typing of Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp. (ESKAPE) pathogens. A 97% agreement (60/62 isolates) was achieved in comparison to pulsed-field gel electrophoresis (PFGE) results, which indicates that LMqPCR HRMA is a rapid and accurate screening tool for monitoring nosocomial outbreaks. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  13. METHOD OF CHEMICAL ANALYSIS FOR OIL SHALE WASTES

    EPA Science Inventory

    Several methods of chemical analysis are described for oil shale wastewaters and retort gases. These methods are designed to support the field testing of various pollution control systems. As such, emphasis has been placed on methods which are rapid and sufficiently rugged to per...

  14. Conventional laboratory methods for cyanotoxins.

    PubMed

    Lawton, Linda A; Edwards, C

    2008-01-01

    It is clear from the literature that numerous methods are available for most cyanotoxins, although many publications on monitoring data indicate that the favored approach is the use proven, robust methods for individual toxins. The most effective approach is the utilization of a robust rapid screen, where positive samples are followed up by qualitative and quantitative analysis to provide the essential decision making data needed for successful management strategies (Fig. 2). Currently, rapid screens are available for microcystins, saxitoxins and anatoxin-a(s), whilst optimisation and validation is needed, many publications report good correlation with the mouse bioassay and HPLC. There is an urgent need for rapid, simple, and inexpensive assays for cylindrospermopsins, anatoxin-a and BMAA. Although methods exist for analysis of BMAA, the fact that a recent study showed 95% of cyanobacteria producing this, some at levels > 6,000 microg g(-1) dry wt, is of concern and rapid screening followed by robust analysis needed. An ideal approach would be a single method capable of extracting and detecting all cyanotoxins. Several publications describe such approaches using LC-MS, but as expected from a group of compounds with diverse chemistry, there are obvious limitations in recoveries during sample processing, chromatographic performance and sensitivity (Dahlmann et al. 2003, Dell'Aversano et al. 2004, Pietsch et al. 2001). Selection of methods must be based on the application requirements, equipment available and cost. For many organisations it may be more cost effective to out-source the occasional analysis. However, as the incidence of blooms appears to be increasing, the need for more rigorous monitoring is needed, sensible investment is needed to meet recommended guidelines. Most of the methods discussed in this paper are suitable for achieving this goal, although clean-up and concentration is usually necessary for physicochemical methods.

  15. Rapid identification of Bacillus anthracis spores in suspicious powder samples by using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS).

    PubMed

    Dybwad, Marius; van der Laaken, Anton L; Blatny, Janet Martha; Paauw, Armand

    2013-09-01

    Rapid and reliable identification of Bacillus anthracis spores in suspicious powders is important to mitigate the safety risks and economic burdens associated with such incidents. The aim of this study was to develop and validate a rapid and reliable laboratory-based matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis method for identifying B. anthracis spores in suspicious powder samples. A reference library containing 22 different Bacillus sp. strains or hoax materials was constructed and coupled with a novel classification algorithm and standardized processing protocol for various powder samples. The method's limit of B. anthracis detection was determined to be 2.5 × 10(6) spores, equivalent to a 55-μg sample size of the crudest B. anthracis-containing powder discovered during the 2001 Amerithrax incidents. The end-to-end analysis method was able to successfully discriminate among samples containing B. anthracis spores, closely related Bacillus sp. spores, and commonly encountered hoax materials. No false-positive or -negative classifications of B. anthracis spores were observed, even when the analysis method was challenged with a wide range of other bacterial agents. The robustness of the method was demonstrated by analyzing samples (i) at an external facility using a different MALDI-TOF MS instrument, (ii) using an untrained operator, and (iii) using mixtures of Bacillus sp. spores and hoax materials. Taken together, the observed performance of the analysis method developed demonstrates its potential applicability as a rapid, specific, sensitive, robust, and cost-effective laboratory-based analysis tool for resolving incidents involving suspicious powders in less than 30 min.

  16. Rapid Identification of Bacillus anthracis Spores in Suspicious Powder Samples by Using Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry (MALDI-TOF MS)

    PubMed Central

    van der Laaken, Anton L.; Blatny, Janet Martha; Paauw, Armand

    2013-01-01

    Rapid and reliable identification of Bacillus anthracis spores in suspicious powders is important to mitigate the safety risks and economic burdens associated with such incidents. The aim of this study was to develop and validate a rapid and reliable laboratory-based matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) analysis method for identifying B. anthracis spores in suspicious powder samples. A reference library containing 22 different Bacillus sp. strains or hoax materials was constructed and coupled with a novel classification algorithm and standardized processing protocol for various powder samples. The method's limit of B. anthracis detection was determined to be 2.5 × 106 spores, equivalent to a 55-μg sample size of the crudest B. anthracis-containing powder discovered during the 2001 Amerithrax incidents. The end-to-end analysis method was able to successfully discriminate among samples containing B. anthracis spores, closely related Bacillus sp. spores, and commonly encountered hoax materials. No false-positive or -negative classifications of B. anthracis spores were observed, even when the analysis method was challenged with a wide range of other bacterial agents. The robustness of the method was demonstrated by analyzing samples (i) at an external facility using a different MALDI-TOF MS instrument, (ii) using an untrained operator, and (iii) using mixtures of Bacillus sp. spores and hoax materials. Taken together, the observed performance of the analysis method developed demonstrates its potential applicability as a rapid, specific, sensitive, robust, and cost-effective laboratory-based analysis tool for resolving incidents involving suspicious powders in less than 30 min. PMID:23811517

  17. The Use of Rapid Review Methods for the U.S. Preventive Services Task Force.

    PubMed

    Patnode, Carrie D; Eder, Michelle L; Walsh, Emily S; Viswanathan, Meera; Lin, Jennifer S

    2018-01-01

    Rapid review products are intended to synthesize available evidence in a timely fashion while still meeting the needs of healthcare decision makers. Various methods and products have been applied for rapid evidence syntheses, but no single approach has been uniformly adopted. Methods to gain efficiency and compress the review time period include focusing on a narrow clinical topic and key questions; limiting the literature search; performing single (versus dual) screening of abstracts and full-text articles for relevance; and limiting the analysis and synthesis. In order to maintain the scientific integrity, including transparency, of rapid evidence syntheses, it is imperative that procedures used to streamline standard systematic review methods are prespecified, based on sound review principles and empiric evidence when possible, and provide the end user with an accurate and comprehensive synthesis. The collection of clinical preventive service recommendations maintained by the U.S. Preventive Services Task Force, along with its commitment to rigorous methods development, provide a unique opportunity to refine, implement, and evaluate rapid evidence synthesis methods and add to an emerging evidence base on rapid review methods. This paper summarizes the U.S. Preventive Services Task Force's use of rapid review methodology, its criteria for selecting topics for rapid evidence syntheses, and proposed methods to streamline the review process. Copyright © 2018 American Journal of Preventive Medicine. All rights reserved.

  18. [Rapid screening the alkaloids of poppy shell in hot pot condiment, beef noodle soup and seasoning by direct analysis in real time-tandem mass spectrometry].

    PubMed

    Zhang, Baile; Gao, Lihong; Xie, Yingshuang; Zhou, Wei; Chen, Xiaofeng; Lei, Chunni; Zhang, Huan

    2017-07-08

    A direct analysis in real time tandem mass spectrometry (DART-MS/MS) method was established for quickly screening five illegally added alkaloids of poppy shell from the hot pot condiment, beef noodle soup and seasoning. The samples were extracted and purified by acetonitrile, and then injected under the conditions of ionization temperature of 300℃, grid electrode voltage of 150 V and sampling rate of 0.8 mm/s using DART in the positive ion mode. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. The method is simple and rapid, and can meet the requirement of rapid screening and analysis of large quantities of samples.

  19. The spa typing of methicillin-resistant Staphylococcus aureus isolates by High Resolution Melting (HRM) analysis.

    PubMed

    Fasihi, Yasser; Fooladi, Saba; Mohammadi, Mohammad Ali; Emaneini, Mohammad; Kalantar-Neyestanaki, Davood

    2017-09-06

    Molecular typing is an important tool for control and prevention of infection. A suitable molecular typing method for epidemiological investigation must be easy to perform, highly reproducible, inexpensive, rapid and easy to interpret. In this study, two molecular typing methods including the conventional PCR-sequencing method and high resolution melting (HRM) analysis were used for staphylococcal protein A (spa) typing of 30 Methicillin-resistant Staphylococcus aureus (MRSA) isolates recovered from clinical samples. Based on PCR-sequencing method results, 16 different spa types were identified among the 30 MRSA isolates. Among the 16 different spa types, 14 spa types separated by HRM method. Two spa types including t4718 and t2894 were not separated from each other. According to our results, spa typing based on HRM analysis method is very rapid, easy to perform and cost-effective, but this method must be standardized for different regions, spa types, and real-time machinery.

  20. Rapid detection and differentiation of avian infectious bronchitis virus: an application of Mass genotype by melting temperature analysis in RT-qPCR using SYBR Green I

    PubMed Central

    OKINO, Cintia Hiromi; MONTASSIER, Maria de Fátima Silva; de OLIVEIRA, Andressa Peres; MONTASSIER, Helio José

    2018-01-01

    A method based on Melting Temperature analysis of Hypervariable regions (HVR) of S1 gene within a RT-qPCR was developed to detect different genotypes of avian infectious bronchitis virus (IBV) and identify the Mass genotype. The method was able to rapidly identify the Mass genotype among IBV field isolates, vaccine attenuated strains and reference M41 strain in allantoic liquid and also directly in tissues. The RT-qPCR developed detected the virus in both tracheal and pulmonary samples from M41-infected or H120-infected birds, in a larger post-infection period compared to detection by standard method of virus isolation. RT-qPCR method tested provided a sensitivity and rapid approach for screening on IBV detection and Mass genotyping from IBV isolates. PMID:29491226

  1. Microgravimetric Analysis Method for Activation-Energy Extraction from Trace-Amount Molecule Adsorption.

    PubMed

    Xu, Pengcheng; Yu, Haitao; Li, Xinxin

    2016-05-03

    Activation-energy (Ea) value for trace-amount adsorption of gas molecules on material is rapidly and inexpensively obtained, for the first time, from a microgravimetric analysis experiment. With the material loaded, a resonant microcantilever is used to record in real time the adsorption process at two temperatures. The kinetic parameter Ea is thereby extracted by solving the Arrhenius equation. As an example, two CO2 capture nanomaterials are examined by the Ea extracting method for evaluation/optimization and, thereby, demonstrating the applicability of the microgravimetric analysis method. The achievement helps to solve the absence in rapid quantitative characterization of sorption kinetics and opens a new route to investigate molecule adsorption processes and materials.

  2. Rapid analysis method for the determination of 14C specific activity in irradiated graphite

    PubMed Central

    Remeikis, Vidmantas; Lagzdina, Elena; Garbaras, Andrius; Gudelis, Arūnas; Garankin, Jevgenij; Juodis, Laurynas; Duškesas, Grigorijus; Lingis, Danielius; Abdulajev, Vladimir; Plukis, Artūras

    2018-01-01

    14C is one of the limiting radionuclides used in the categorization of radioactive graphite waste; this categorization is crucial in selecting the appropriate graphite treatment/disposal method. We propose a rapid analysis method for 14C specific activity determination in small graphite samples in the 1–100 μg range. The method applies an oxidation procedure to the sample, which extracts 14C from the different carbonaceous matrices in a controlled manner. Because this method enables fast online measurement and 14C specific activity evaluation, it can be especially useful for characterizing 14C in irradiated graphite when dismantling graphite moderator and reflector parts, or when sorting radioactive graphite waste from decommissioned nuclear power plants. The proposed rapid method is based on graphite combustion and the subsequent measurement of both CO2 and 14C, using a commercial elemental analyser and the semiconductor detector, respectively. The method was verified using the liquid scintillation counting (LSC) technique. The uncertainty of this rapid method is within the acceptable range for radioactive waste characterization purposes. The 14C specific activity determination procedure proposed in this study takes approximately ten minutes, comparing favorably to the more complicated and time consuming LSC method. This method can be potentially used to radiologically characterize radioactive waste or used in biomedical applications when dealing with the specific activity determination of 14C in the sample. PMID:29370233

  3. Rapid analysis method for the determination of 14C specific activity in irradiated graphite.

    PubMed

    Remeikis, Vidmantas; Lagzdina, Elena; Garbaras, Andrius; Gudelis, Arūnas; Garankin, Jevgenij; Plukienė, Rita; Juodis, Laurynas; Duškesas, Grigorijus; Lingis, Danielius; Abdulajev, Vladimir; Plukis, Artūras

    2018-01-01

    14C is one of the limiting radionuclides used in the categorization of radioactive graphite waste; this categorization is crucial in selecting the appropriate graphite treatment/disposal method. We propose a rapid analysis method for 14C specific activity determination in small graphite samples in the 1-100 μg range. The method applies an oxidation procedure to the sample, which extracts 14C from the different carbonaceous matrices in a controlled manner. Because this method enables fast online measurement and 14C specific activity evaluation, it can be especially useful for characterizing 14C in irradiated graphite when dismantling graphite moderator and reflector parts, or when sorting radioactive graphite waste from decommissioned nuclear power plants. The proposed rapid method is based on graphite combustion and the subsequent measurement of both CO2 and 14C, using a commercial elemental analyser and the semiconductor detector, respectively. The method was verified using the liquid scintillation counting (LSC) technique. The uncertainty of this rapid method is within the acceptable range for radioactive waste characterization purposes. The 14C specific activity determination procedure proposed in this study takes approximately ten minutes, comparing favorably to the more complicated and time consuming LSC method. This method can be potentially used to radiologically characterize radioactive waste or used in biomedical applications when dealing with the specific activity determination of 14C in the sample.

  4. A RAPID DNA EXTRACTION METHOD IS SUCCESSFULLY APPLIED TO ITS-RFLP ANALYSIS OF MYCORRHIZAL ROOT TIPS

    EPA Science Inventory

    A rapid method for extracting DNA from intact, single root tips using a Xanthine solution was developed to handle very large numbers of analyses of ectomycorrhizas. By using an extraction without grinding we have attempted to bias the extraction towards the fungal DNA in the man...

  5. EVALUATION OF QUANTITATIVE REAL TIME PCR FOR THE MEASUREMENT OF HELICOBATER PYLORI AT LOW CONCENTRATIONS IN DRINKING WATER

    EPA Science Inventory

    Aims: To determine the performance of a rapid, real time polymerase chain reaction (PCR) method for the detection and quantitative analysis Helicobacter pylori at low concentrations in drinking water.

    Methods and Results: A rapid DNA extraction and quantitative PCR (QPCR)...

  6. RAPID AND PRECISE METHOD FOR MEASURING STABLE CARBON ISOTOPE RATIOS OF DISSOLVED INORGANIC CARBON

    EPA Science Inventory

    We describe a method for rapid preparation, concentration and stable isotopic analysis of dissolved inorganic carbon (d13C-DIC). Liberation of CO2 was accomplished by placing 100 ?l phosphoric acid and 0.9 ml water in an evacuated 1.7-ml gas chromatography (GC) injection vial. Fo...

  7. A critical analysis of methods for rapid and nondestructive determination of wood density in standing trees

    Treesearch

    Shan Gao; Xiping Wang; Michael C. Wiemann; Brian K. Brashaw; Robert J. Ross; Lihai Wang

    2017-01-01

    Key message Field methods for rapid determination of wood density in trees have evolved from increment borer, torsiometer, Pilodyn, and nail withdrawal into sophisticated electronic tools of resistance drilling measurement. A partial resistance drilling approach coupled with knowledge of internal tree density distribution may...

  8. Analysis of Rare Earth Elements in Uranium Using Handheld Laser-Induced Breakdown Spectroscopy (HH LIBS)

    DOE PAGES

    Manard, Benjamin T.; Wylie, E. Miller; Willson, Stephen P.

    2018-05-22

    In this paper, a portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb)more » were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). Finally, it was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.« less

  9. Analysis of Rare Earth Elements in Uranium Using Handheld Laser-Induced Breakdown Spectroscopy (HH LIBS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manard, Benjamin T.; Wylie, E. Miller; Willson, Stephen P.

    In this paper, a portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb)more » were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). Finally, it was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.« less

  10. Analysis of Rare Earth Elements in Uranium Using Handheld Laser-Induced Breakdown Spectroscopy (HH LIBS).

    PubMed

    Manard, Benjamin T; Wylie, E Miller; Willson, Stephen P

    2018-01-01

    A portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb) were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). It was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.

  11. Rapid analysis of Aurantii Fructus Immaturus (Zhishi) using paper spray ionization mass spectrometry.

    PubMed

    Liu, Xuemei; Gu, Zhixin; Guo, Yuan; Liu, Jingjing; Ma, Ming; Chen, Bo; Wang, Liping

    2017-04-15

    Paper spray-mass spectrometry (PS-MS) is a rapid, solvent-efficient, and high-throughput analytical method for analyzing complex samples. In this study, a PS-MS method was developed to obtain MS profiles of Aurantii Fructus Immaturus (aka Zhishi in Chinese) in positive and negative ion modes. In combination with multivariate analyses, including principal component analysis and cluster analysis, the PS-MS profiles of 25 batches of Zhishi were discriminated in 25 batches of Citri Reticulatae Pericarpium Viride (aka Qingpi in Chinese; an adulterant of Zhishi). Moreover, a rapid quantitative analysis of synephrine, a prescriptive quality control component of Zhishi listed in the Chinese Pharmacopoeia, was conducted with PS-MS using synephrine-d2 as an internal standard (IS). The linearity range was 1.68-16.8μg/mL (R 2 =0.9985), the limit of quantitation was 0.5μg/mL. Relative standard deviations in the intra- and inter-day precision of the MS were 4.87 and 4.90%, respectively. Compared with HPLC results, there was no significant difference in the quantitation of synephrine. This study demonstrated that the PS-MS method is useful for the rapid discrimination and quality control of Zhishi samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Rapid Radiochemical Method for Isotopic Uranium in Building ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Uranium-234, uranium-235, and uranium-238 in concrete and brick samples Method Selected for: SAM lists this method for qualitative analysis of uranium-234, uranium-235, and uranium-238 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  13. High resolution melting analysis: rapid and precise characterisation of recombinant influenza A genomes

    PubMed Central

    2013-01-01

    Background High resolution melting analysis (HRM) is a rapid and cost-effective technique for the characterisation of PCR amplicons. Because the reverse genetics of segmented influenza A viruses allows the generation of numerous influenza A virus reassortants within a short time, methods for the rapid selection of the correct recombinants are very useful. Methods PCR primer pairs covering the single nucleotide polymorphism (SNP) positions of two different influenza A H5N1 strains were designed. Reassortants of the two different H5N1 isolates were used as a model to prove the suitability of HRM for the selection of the correct recombinants. Furthermore, two different cycler instruments were compared. Results Both cycler instruments generated comparable average melting peaks, which allowed the easy identification and selection of the correct cloned segments or reassorted viruses. Conclusions HRM is a highly suitable method for the rapid and precise characterisation of cloned influenza A genomes. PMID:24028349

  14. Rapid detection of Escherichia coli and enterococci in recreational water using an immunomagnetic separation/adenosine triphosphate technique

    USGS Publications Warehouse

    Bushon, R.N.; Brady, A.M.; Likirdopulos, C.A.; Cireddu, J.V.

    2009-01-01

    Aims: The aim of this study was to examine a rapid method for detecting Escherichia coli and enterococci in recreational water. Methods and Results: Water samples were assayed for E. coli and enterococci by traditional and immunomagnetic separation/adenosine triphosphate (IMS/ATP) methods. Three sample treatments were evaluated for the IMS/ATP method: double filtration, single filtration, and direct analysis. Pearson's correlation analysis showed strong, significant, linear relations between IMS/ATP and traditional methods for all sample treatments; strongest linear correlations were with the direct analysis (r = 0.62 and 0.77 for E. coli and enterococci, respectively). Additionally, simple linear regression was used to estimate bacteria concentrations as a function of IMS/ATP results. The correct classification of water-quality criteria was 67% for E. coli and 80% for enterococci. Conclusions: The IMS/ATP method is a viable alternative to traditional methods for faecal-indicator bacteria. Significance and Impact of the Study: The IMS/ATP method addresses critical public health needs for the rapid detection of faecal-indicator contamination and has potential for satisfying US legislative mandates requiring methods to detect bathing water contamination in 2 h or less. Moreover, IMS/ATP equipment is considerably less costly and more portable than that for molecular methods, making the method suitable for field applications. ?? 2009 The Authors.

  15. [Applications of near-infrared spectroscopy to analysis of traditional Chinese herbal medicine].

    PubMed

    Li, Yan-Zhou; Min, Shun-Geng; Liu, Xia

    2008-07-01

    Analysis of traditional Chinese herbal medicine is of great importance to its quality control Conventional analysis methods can not meet the requirement of rapid and on-line analysis because of complex process more experiences or needed. In recent years, near-infrared spectroscopy technique has been used for rapid determination of active components, on-line quality control, identification of counterfeit and discrimination of geographical origins of herbal medicines and so on, due to its advantages of simple pretreatment, high efficiency, convenience to use solid diffuse reflection spectroscopy and fiber. In the present paper, the principles and methods of near-infrared spectroscopy technique are introduced concisely. Especially, the applications of this technique in quantitative analysis and qualitative analysis of traditional Chinese herbal medicine are reviewed.

  16. Rapid analysis of scattering from periodic dielectric structures using accelerated Cartesian expansions

    DOE PAGES

    Baczewski, Andrew David; Miller, Nicholas C.; Shanker, Balasubramaniam

    2012-03-22

    Here, the analysis of fields in periodic dielectric structures arise in numerous applications of recent interest, ranging from photonic bandgap structures and plasmonically active nanostructures to metamaterials. To achieve an accurate representation of the fields in these structures using numerical methods, dense spatial discretization is required. This, in turn, affects the cost of analysis, particularly for integral-equation-based methods, for which traditional iterative methods require Ο(Ν 2) operations, Ν being the number of spatial degrees of freedom. In this paper, we introduce a method for the rapid solution of volumetric electric field integral equations used in the analysis of doubly periodicmore » dielectric structures. The crux of our method is the accelerated Cartesian expansion algorithm, which is used to evaluate the requisite potentials in Ο(Ν) cost. Results are provided that corroborate our claims of acceleration without compromising accuracy, as well as the application of our method to a number of compelling photonics applications.« less

  17. Pre-Steady-State Kinetic Analysis of Single-Nucleotide Incorporation by DNA Polymerases

    PubMed Central

    Su, Yan; Guengerich, F. Peter

    2016-01-01

    Pre-steady-state kinetic analysis is a powerful and widely used method to obtain multiple kinetic parameters. This protocol provides a step-by-step procedure for pre-steady-state kinetic analysis of single-nucleotide incorporation by a DNA polymerase. It describes the experimental details of DNA substrate annealing, reaction mixture preparation, handling of the RQF-3 rapid quench-flow instrument, denaturing polyacrylamide DNA gel preparation, electrophoresis, quantitation, and data analysis. The core and unique part of this protocol is the rationale for preparation of the reaction mixture (the ratio of the polymerase to the DNA substrate) and methods for conducting pre-steady-state assays on an RQF-3 rapid quench-flow instrument, as well as data interpretation after analysis. In addition, the methods for the DNA substrate annealing and DNA polyacrylamide gel preparation, electrophoresis, quantitation and analysis are suitable for use in other studies. PMID:27248785

  18. Rapid Analysis of Bisphenol A and Its Analogues in Food Packaging Products by Paper Spray Ionization Mass Spectrometry.

    PubMed

    Chen, Shuo; Chang, Quanying; Yin, Kai; He, Qunying; Deng, Yongxiu; Chen, Bo; Liu, Chengbin; Wang, Ying; Wang, Liping

    2017-06-14

    In this study, a paper spray ionization mass spectrometric (PS-MS) method was developed for the rapid in situ screening and simultaneous quantitative analysis of bisphenol A and its analogues, i.e., bisphenol S, bisphenol F, and bisphenol AF, in food packaging products. At the optimal PS-MS conditions, the calibration curves of bisphenols in the range of 1-100 μg/mL were linear. The correlation coefficients were higher than 0.998, and the LODs of the target compounds were 0.1-0.3 μg/mL. After a simple treatment by dichloromethane on the surface, the samples were analyzed by PS-MS in situ for rapid screening without a traditional sample pretreatment procedure, such as powdering, extraction, and enrichment steps. The analytical time of the PS-MS method was less than 1 min. In comparison with conventional HPLC-MS/MS, it was demonstrated that PS-MS was a more effective high-throughput screening and quantitative analysis method.

  19. Validation of Rapid Radiochemical Method for Californium ...

    EPA Pesticide Factsheets

    Technical Brief In the event of a radiological/nuclear contamination event, the response community would need tools and methodologies to rapidly assess the nature and the extent of contamination. To characterize a radiologically contaminated outdoor area and to inform risk assessment, large numbers of environmental samples would be collected and analyzed over a short period of time. To address the challenge of quickly providing analytical results to the field, the U.S. EPA developed a robust analytical method. This method allows response officials to characterize contaminated areas and to assess the effectiveness of remediation efforts, both rapidly and accurately, in the intermediate and late phases of environmental cleanup. Improvement in sample processing and analysis leads to increased laboratory capacity to handle the analysis of a large number of samples following the intentional or unintentional release of a radiological/nuclear contaminant.

  20. [Rapid detection of caffeine in blood by freeze-out extraction].

    PubMed

    Bekhterev, V N; Gavrilova, S N; Kozina, E P; Maslakov, I V

    2010-01-01

    A new method for the detection of caffeine in blood has been proposed based on the combination of extraction and freezing-out to eliminate the influence of sample matrix. Metrological characteristics of the method are presented. Selectivity of detection is achieved by optimal conditions of analysis by high performance liquid chromatography. The method is technically simple and cost-efficient, it ensures rapid performance of the studies.

  1. A method for the quantitative determination of crystalline phases by X-ray

    NASA Technical Reports Server (NTRS)

    Petzenhauser, I.; Jaeger, P.

    1988-01-01

    A mineral analysis method is described for rapid quantitative determination of crystalline substances in those cases in which the sample is present in pure form or in a mixture of known composition. With this method there is no need for prior chemical analysis.

  2. An Improved Manual Method for NOx Emission Measurement.

    ERIC Educational Resources Information Center

    Dee, L. A.; And Others

    The current manual NO (x) sampling and analysis method was evaluated. Improved time-integrated sampling and rapid analysis methods were developed. In the new method, the sample gas is drawn through a heated bed of uniquely active, crystalline, Pb02 where NO (x) is quantitatively absorbed. Nitrate ion is later extracted with water and the…

  3. Rapid analysis of lignans from leaves of Podophyllum peltatum l. samples using UPLC-UV-MS

    USDA-ARS?s Scientific Manuscript database

    A new rapid UPLC-UV-MS method has been developed that permits the analysis of four lignans in P. peltatum L. Podophyllotoxin is a natural lignan that is being used as a precursor for the semi-synthetic anti-cancer drugs etoposide, teniposide and etopophos. The chromatographic separation was achieved...

  4. Rapid analysis of lignans from leaves of Podophyllum peltatum L samples using UPLC-UV-MS

    USDA-ARS?s Scientific Manuscript database

    A new rapid UPLC-UV-MS method has been developed that permits the analysis of four lignans in P. peltatum L. Podophyllotoxin is a natural lignan that is being used as a precursor for the semi-synthetic anti-cancer drugs etoposide, teniposide and etopophos. The chromatographic separation was achieved...

  5. Expediting the Analysis of Qualitative Data in Evaluation: A Procedure for the Rapid Identification of Themes from Audio Recordings (RITA)

    ERIC Educational Resources Information Center

    Neal, Jennifer Watling; Neal, Zachary P.; VanDyke, Erika; Kornbluh, Mariah

    2015-01-01

    Qualitative data offer advantages to evaluators, including rich information about stakeholders' perspectives and experiences. However, qualitative data analysis is labor-intensive and slow, conflicting with evaluators' needs to provide punctual feedback to their clients. In this method note, we contribute to the literature on rapid evaluation and…

  6. Comparative Validation of the Determination of Sofosbuvir in Pharmaceuticals by Several Inexpensive Ecofriendly Chromatographic, Electrophoretic, and Spectrophotometric Methods.

    PubMed

    El-Yazbi, Amira F

    2017-07-01

    Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virus infection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with P-value > 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.

  7. Rapid detection of bacteria with miniaturized pyrolysis-gas chromatographic analysis

    NASA Astrophysics Data System (ADS)

    Mowry, Curtis; Morgan, Catherine H.; Baca, Quentin; Manginell, Ronald P.; Kottenstette, Richard J.; Lewis, Patrick; Frye-Mason, Gregory C.

    2002-02-01

    Rapid detection and identification of bacteria and other pathogens is important for many civilian and military applications. The profiles of biological markers such as fatty acids can be used to characterize biological samples or to distinguish bacteria at the gram-type, genera, and even species level. Common methods for whole cell bacterial analysis are neither portable nor rapid, requiring lengthy, labor intensive sample preparation and bench-scale instrumentation. These methods chemically derivatize fatty acids to produce more volatile fatty acid methyl esters (FAMEs) that can be separated and analyzed by a gas chromatograph (GC)/mass spectrometer. More recent publications demonstrate decreased sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis/derivatization. Ongoing development of miniaturized pyrolysis/GC instrumentation by this department capitalizes on Sandia advances in the field of microfabricated chemical analysis systems ((mu) ChemLab). Microdevices include rapidly heated stages capable of pyrolysis or sample concentration, gas chromatography columns, and surface acoustic wave (SAW) sensor arrays. We will present results demonstrating the capabilities of these devices toward fulfilling the goal of portable, rapid detection and early warning of the presence of pathogens in air or water.

  8. Rapid detection of undesired cosmetic ingredients by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Ouyang, Jie; An, Dongli; Chen, Tengteng; Lin, Zhiwei

    2017-10-01

    In recent years, cosmetic industry profits soared due to the widespread use of cosmetics, which resulted in illicit manufacturers and products of poor quality. Therefore, the rapid and accurate detection of the composition of cosmetics has become crucial. At present, numerous methods, such as gas chromatography and liquid chromatography-mass spectrometry, were available for the analysis of cosmetic ingredients. However, these methods present several limitations, such as failure to perform comprehensive and rapid analysis of the samples. Compared with other techniques, matrix-assisted laser desorption ionization time-of-flight mass spectrometry offered the advantages of wide detection range, fast speed and high accuracy. In this article, we briefly summarized how to select a suitable matrix and adjust the appropriate laser energy. We also discussed the rapid identification of undesired ingredients, focusing on antibiotics and hormones in cosmetics.

  9. Rapid quantitative analysis of 8-iso-prostaglandin-F(2alpha) using liquid chromatography-tandem mass spectrometry and comparison with an enzyme immunoassay method.

    PubMed

    Dahl, Jeffrey H; van Breemen, Richard B

    2010-09-15

    A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed for the measurement of urinary 8-iso-prostaglandin F(2alpha) (8-iso-PGF(2alpha)), a biomarker of lipid peroxidation. Because urine contains numerous F(2) prostaglandin isomers, each with identical mass and similar mass spectrometric fragmentation patterns, chromatographic separation of 8-iso-PGF(2alpha) from its isomers is necessary for its quantitative analysis using MS/MS. We were able to achieve this separation using an isocratic LC method with a run time of less than 9min, which is at least threefold faster than previous methods, while maintaining sensitivity, accuracy, precision, and reliability. The limits of detection and quantitation were 53 and 178pg/ml urine, respectively. We compared our method with a commercially available affinity purification and enzyme immunoassay kit and found both assays to be in agreement. Despite the high sensitivity of the enzyme immunoassay method, it is more expensive and has a narrower dynamic range than LC-MS/MS. Our method was optimized for rapid measurement of 8-iso-PGF(2alpha) in urine, and it is ideally suited for clinical sample analysis. 2010 Elsevier Inc. All rights reserved.

  10. Rapid Harmonic Analysis of Piezoelectric MEMS Resonators.

    PubMed

    Puder, Jonathan M; Pulskamp, Jeffrey S; Rudy, Ryan Q; Cassella, Cristian; Rinaldi, Matteo; Chen, Guofeng; Bhave, Sunil A; Polcawich, Ronald G

    2018-06-01

    This paper reports on a novel simulation method combining the speed of analytical evaluation with the accuracy of finite-element analysis (FEA). This method is known as the rapid analytical-FEA technique (RAFT). The ability of the RAFT to accurately predict frequency response orders of magnitude faster than conventional simulation methods while providing deeper insights into device design not possible with other types of analysis is detailed. Simulation results from the RAFT across wide bandwidths are compared to measured results of resonators fabricated with various materials, frequencies, and topologies with good agreement. These include resonators targeting beam extension, disk flexure, and Lamé beam modes. An example scaling analysis is presented and other applications enabled are discussed as well. The supplemental material includes example code for implementation in ANSYS, although any commonly employed FEA package may be used.

  11. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues

    NASA Astrophysics Data System (ADS)

    Ji, Wei; Yao, Weirong

    2015-06-01

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm-1, 1344 cm-1, 1596 cm-1, which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm-1 was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R2 = 0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples.

  12. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues.

    PubMed

    Ji, Wei; Yao, Weirong

    2015-06-05

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm(-1), 1344 cm(-1), 1596 cm(-1), which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm(-1) was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R(2)=0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Microfluidic systems and methods of transport and lysis of cells and analysis of cell lysate

    DOEpatents

    Culbertson, Christopher T.; Jacobson, Stephen C.; McClain, Maxine A.; Ramsey, J. Michael

    2004-08-31

    Microfluidic systems and methods are disclosed which are adapted to transport and lyse cellular components of a test sample for analysis. The disclosed microfluidic systems and methods, which employ an electric field to rupture the cell membrane, cause unusually rapid lysis, thereby minimizing continued cellular activity and resulting in greater accuracy of analysis of cell processes.

  14. Microfluidic systems and methods for transport and lysis of cells and analysis of cell lysate

    DOEpatents

    Culbertson, Christopher T [Oak Ridge, TN; Jacobson, Stephen C [Knoxville, TN; McClain, Maxine A [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-02

    Microfluidic systems and methods are disclosed which are adapted to transport and lyse cellular components of a test sample for analysis. The disclosed microfluidic systems and methods, which employ an electric field to rupture the cell membrane, cause unusually rapid lysis, thereby minimizing continued cellular activity and resulting in greater accuracy of analysis of cell processes.

  15. Rapid analysis of sugars in honey by processing Raman spectrum using chemometric methods and artificial neural networks.

    PubMed

    Özbalci, Beril; Boyaci, İsmail Hakkı; Topcu, Ali; Kadılar, Cem; Tamer, Uğur

    2013-02-15

    The aim of this study was to quantify glucose, fructose, sucrose and maltose contents of honey samples using Raman spectroscopy as a rapid method. By performing a single measurement, quantifications of sugar contents have been said to be unaffordable according to the molecular similarities between sugar molecules in honey matrix. This bottleneck was overcome by coupling Raman spectroscopy with chemometric methods (principal component analysis (PCA) and partial least squares (PLS)) and an artificial neural network (ANN). Model solutions of four sugars were processed with PCA and significant separation was observed. This operation, done with the spectral features by using PLS and ANN methods, led to the discriminant analysis of sugar contents. Models/trained networks were created using a calibration data set and evaluated using a validation data set. The correlation coefficient values between actual and predicted values of glucose, fructose, sucrose and maltose were determined as 0.964, 0.965, 0.968 and 0.949 for PLS and 0.965, 0.965, 0.978 and 0.956 for ANN, respectively. The requirement of rapid analysis of sugar contents of commercial honeys has been met by the data processed within this article. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Suspect Screening of Chemicals in Consumer Products

    EPA Science Inventory

    This presentation details a pilot suspect screening analysis (SSA) of common consumer products done under the Rapid Exposure and Dosimetry project of CSS. This work presents methods which can rapidly characterize chemicals identified in consumer products including formulations (s...

  17. Rapid Analysis of Trace Drugs and Metabolites Using a Thermal Desorption DART-MS Configuration.

    PubMed

    Sisco, Edward; Forbes, Thomas P; Staymates, Matthew E; Gillen, Greg

    2016-01-01

    The need to analyze trace narcotic samples rapidly for screening or confirmatory purposes is of increasing interest to the forensic, homeland security, and criminal justice sectors. This work presents a novel method for the detection and quantification of trace drugs and metabolites off of a swipe material using a thermal desorption direct analysis in real time mass spectrometry (TD-DART-MS) configuration. A variation on traditional DART, this configuration allows for desorption of the sample into a confined tube, completely independent of the DART source, allowing for more efficient and thermally precise analysis of material present on a swipe. Over thirty trace samples of narcotics, metabolites, and cutting agents deposited onto swipes were rapidly differentiated using this methodology. The non-optimized method led to sensitivities ranging from single nanograms to hundreds of picograms. Direct comparison to traditional DART with a subset of the samples highlighted an improvement in sensitivity by a factor of twenty to thirty and an increase in reproducibility sample to sample from approximately 45 % RSD to less than 15 % RSD. Rapid extraction-less quantification was also possible.

  18. Rapid characterization of microorganisms by mass spectrometry--what can be learned and how?

    PubMed

    Fenselau, Catherine C

    2013-08-01

    Strategies for the rapid and reliable analysis of microorganisms have been sought to meet national needs in defense, homeland security, space exploration, food and water safety, and clinical diagnosis. Mass spectrometry has long been a candidate technique because it is extremely rapid and can provide highly specific information. It has excellent sensitivity. Molecular and fragment ion masses provide detailed fingerprints, which can also be interpreted. Mass spectrometry is also a broad band method--everything has a mass--and it is automatable. Mass spectrometry is a physiochemical method that is orthogonal and complementary to biochemical and morphological methods used to characterize microorganisms.

  19. Multifunctional Collaborative Modeling and Analysis Methods in Engineering Science

    NASA Technical Reports Server (NTRS)

    Ransom, Jonathan B.; Broduer, Steve (Technical Monitor)

    2001-01-01

    Engineers are challenged to produce better designs in less time and for less cost. Hence, to investigate novel and revolutionary design concepts, accurate, high-fidelity results must be assimilated rapidly into the design, analysis, and simulation process. This assimilation should consider diverse mathematical modeling and multi-discipline interactions necessitated by concepts exploiting advanced materials and structures. Integrated high-fidelity methods with diverse engineering applications provide the enabling technologies to assimilate these high-fidelity, multi-disciplinary results rapidly at an early stage in the design. These integrated methods must be multifunctional, collaborative, and applicable to the general field of engineering science and mechanics. Multifunctional methodologies and analysis procedures are formulated for interfacing diverse subdomain idealizations including multi-fidelity modeling methods and multi-discipline analysis methods. These methods, based on the method of weighted residuals, ensure accurate compatibility of primary and secondary variables across the subdomain interfaces. Methods are developed using diverse mathematical modeling (i.e., finite difference and finite element methods) and multi-fidelity modeling among the subdomains. Several benchmark scalar-field and vector-field problems in engineering science are presented with extensions to multidisciplinary problems. Results for all problems presented are in overall good agreement with the exact analytical solution or the reference numerical solution. Based on the results, the integrated modeling approach using the finite element method for multi-fidelity discretization among the subdomains is identified as most robust. The multiple-method approach is advantageous when interfacing diverse disciplines in which each of the method's strengths are utilized. The multifunctional methodology presented provides an effective mechanism by which domains with diverse idealizations are interfaced. This capability rapidly provides the high-fidelity results needed in the early design phase. Moreover, the capability is applicable to the general field of engineering science and mechanics. Hence, it provides a collaborative capability that accounts for interactions among engineering analysis methods.

  20. Rapid detection of bacterial pathogens using flourescence spectroscopy and chemometrics

    USDA-ARS?s Scientific Manuscript database

    This work presents the development of a method for rapid bacterial identification based on the fluorescence spectroscopy combined with multivariate analysis. Fluorescence spectra of pure three different genera of bacteria (Escherichia coli, Salmonella, and Campylobacter) were collected from 200...

  1. Detection of dopamine in dopaminergic cell using nanoparticles-based barcode DNA analysis.

    PubMed

    An, Jeung Hee; Kim, Tae-Hyung; Oh, Byung-Keun; Choi, Jeong Woo

    2012-01-01

    Nanotechnology-based bio-barcode-amplification analysis may be an innovative approach to dopamine detection. In this study, we evaluated the efficacy of this bio-barcode DNA method in detecting dopamine from dopaminergic cells. Herein, a combination DNA barcode and bead-based immunoassay for neurotransmitter detection with PCR-like sensitivity is described. This method relies on magnetic nanoparticles with antibodies and nanoparticles that are encoded with DNA, and antibodies that can sandwich the target protein captured by the nanoparticle-bound antibodies. The aggregate sandwich structures are magnetically separated from solution, and treated in order to remove the conjugated barcode DNA. The DNA barcodes were then identified via PCR analysis. The dopamine concentration in dopaminergic cells can be readily and rapidly detected via the bio-barcode assay method. The bio-barcode assay method is, therefore, a rapid and high-throughput screening tool for the detection of neurotransmitters such as dopamine.

  2. A novel method for qualitative analysis of edible oil oxidation using an electronic nose.

    PubMed

    Xu, Lirong; Yu, Xiuzhu; Liu, Lei; Zhang, Rui

    2016-07-01

    An electronic nose (E-nose) was used for rapid assessment of the degree of oxidation in edible oils. Peroxide and acid values of edible oil samples were analyzed using data obtained by the American Oil Chemists' Society (AOCS) Official Method for reference. Qualitative discrimination between non-oxidized and oxidized oils was conducted using the E-nose technique developed in combination with cluster analysis (CA), principal component analysis (PCA), and linear discriminant analysis (LDA). The results from CA, PCA and LDA indicated that the E-nose technique could be used for differentiation of non-oxidized and oxidized oils. LDA produced slightly better results than CA and PCA. The proposed approach can be used as an alternative to AOCS Official Method as an innovative tool for rapid detection of edible oil oxidation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. A complementation assay for in vivo protein structure/function analysis in Physcomitrella patens (Funariaceae)

    DOE PAGES

    Scavuzzo-Duggan, Tess R.; Chaves, Arielle M.; Roberts, Alison W.

    2015-07-14

    Here, a method for rapid in vivo functional analysis of engineered proteins was developed using Physcomitrella patens. A complementation assay was designed for testing structure/function relationships in cellulose synthase (CESA) proteins. The components of the assay include (1) construction of test vectors that drive expression of epitope-tagged PpCESA5 carrying engineered mutations, (2) transformation of a ppcesa5 knockout line that fails to produce gametophores with test and control vectors, (3) scoring the stable transformants for gametophore production, (4) statistical analysis comparing complementation rates for test vectors to positive and negative control vectors, and (5) analysis of transgenic protein expression by Westernmore » blotting. The assay distinguished mutations that generate fully functional, nonfunctional, and partially functional proteins. In conclusion, compared with existing methods for in vivo testing of protein function, this complementation assay provides a rapid method for investigating protein structure/function relationships in plants.« less

  4. Quad-Tree Visual-Calculus Analysis of Satellite Coverage

    NASA Technical Reports Server (NTRS)

    Lo, Martin W.; Hockney, George; Kwan, Bruce

    2003-01-01

    An improved method of analysis of coverage of areas of the Earth by a constellation of radio-communication or scientific-observation satellites has been developed. This method is intended to supplant an older method in which the global-coverage-analysis problem is solved from a ground-to-satellite perspective. The present method provides for rapid and efficient analysis. This method is derived from a satellite-to-ground perspective and involves a unique combination of two techniques for multiresolution representation of map features on the surface of a sphere.

  5. [Rapid analysis on phenolic compounds in Rheum palmatum based on UPLC-Q-TOF/MSE combined with diagnostic ions filter].

    PubMed

    Wang, Qing; Lu, Zhi-Wei; Liu, Yue-Hong; Wang, Ming-Ling; Fu, Shuang; Zhang, Qing-Qing; Zhao, Hui-Zhen; Zhang, Zhi-Xin; Xie, Zi-Ye; Huang, Zheng-Hai; Yu, Hong-Hong; Zhou, Wen-Juan; Gao, Xiao-Yan

    2017-05-01

    Diagnostic ions filter method was used to rapidly detect and identify the phenolic compounds in Rheum palmatum based on ultra performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF/MSE). The representative authentic standards of phenolic compounds, including gallic acid, (+)-catechin, (-)-epicatechin, (-)-epicatechin-3-O-gallate and procyanidin B2, were subjected to analysis by UPLC-Q-TOF/MSE system with negative ion mode. Fragmentation patterns of each standard were summarized based on assigned fragment ions. The prominent product ions were selected as diagnostic ions. Subsequently, diagnostic ions filter was employed to rapidly recognize analogous skeletons. Combined with retention time, accurate mass, characteristic fragments and previous literature data, the structures of the filtered compounds were identified or tentatively characterized. A total 63 phenolic compounds (36 phenolic acid derivatives, 8 flavonoid derivatives and 19 tennis derivatives) in R. palmatum were identified, including 6 potential new compounds. The method of diagnostic ions filter could rapidly detect and identify phenolic compounds in R. palmatum This study provides a method for rapid detection of phenolic compounds in R. palmatum and is expected to complete the material basis of rhubarb. Copyright© by the Chinese Pharmaceutical Association.

  6. Newspaper reporting and the emergence of charcoal burning suicide in Taiwan: A mixed methods approach.

    PubMed

    Chen, Ying-Yeh; Tsai, Chi-Wei; Biddle, Lucy; Niederkrotenthaler, Thomas; Wu, Kevin Chien-Chang; Gunnell, David

    2016-03-15

    It has been suggested that extensive media reporting of charcoal burning suicide was a key factor in the rapid spread of this novel method in many East Asian countries. But very few empirical studies have explored the relationship between media reporting and the emergence of this new method of suicide. We investigated the changing pattern of media reporting of charcoal burning suicides in Taiwan during 1998-2002 when this method of suicide increased most rapidly, assessing whether the characteristics of media reporting were associated with the changing incidence of suicide using this method. A mixed method approach, combining quantitative and qualitative analysis of newspaper content during 1998-2002 was used. We compared differences in reporting characteristics before and after the rapid increase in charcoal burning suicide. Point-biserial and Pearson correlation coefficients were calculated to quantify the associations between the media item content and changes in suicide rates. During the period when charcoal burning suicide increased rapidly, the number of reports per suicide was considerably higher than during the early stage (0.31 vs. 0.10). Detailed reporting of this new method was associated with a post-reporting increase in suicides using the method. Qualitative analysis of news items revealed that the content of reports of suicide by charcoal burning changed gradually; in the early stages of the epidemic (1999-2000) there was convergence in the terminology used to report charcoal burning deaths, later reports gave detailed descriptions of the setting in which the death occurred (2001) and finally the method was glamourized and widely publicized (2001-2002). Our analysis was restricted to newspaper reports and did not include TV or the Internet. Newspaper reporting was associated with the evolution and establishment of charcoal burning suicide. Working with media and close monitoring of changes in the incidence of suicide using a new method might help prevent a suicide epidemic such as charcoal burning suicide seen in Taiwan. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Comparative Validation of the Determination of Sofosbuvir in Pharmaceuticals by Several Inexpensive Ecofriendly Chromatographic, Electrophoretic, and Spectrophotometric Methods.

    PubMed

    El-Yazbi, Amira F

    2017-01-20

    Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virusinfection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with <em>P</em>-value &#x003E; 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.

  8. Direct rapid analysis of trace bioavailable soil macronutrients by chemometrics-assisted energy dispersive X-ray fluorescence and scattering spectrometry.

    PubMed

    Kaniu, M I; Angeyo, K H; Mwala, A K; Mangala, M J

    2012-06-04

    Precision agriculture depends on the knowledge and management of soil quality (SQ), which calls for affordable, simple and rapid but accurate analysis of bioavailable soil nutrients. Conventional SQ analysis methods are tedious and expensive. We demonstrate the utility of a new chemometrics-assisted energy dispersive X-ray fluorescence and scattering (EDXRFS) spectroscopy method we have developed for direct rapid analysis of trace 'bioavailable' macronutrients (i.e. C, N, Na, Mg, P) in soils. The method exploits, in addition to X-ray fluorescence, the scatter peaks detected from soil pellets to develop a model for SQ analysis. Spectra were acquired from soil samples held in a Teflon holder analyzed using (109)Cd isotope source EDXRF spectrometer for 200 s. Chemometric techniques namely principal component analysis (PCA), partial least squares (PLS) and artificial neural networks (ANNs) were utilized for pattern recognition based on fluorescence and Compton scatter peaks regions, and to develop multivariate quantitative calibration models based on Compton scatter peak respectively. SQ analyses were realized with high CMD (R(2)>0.9) and low SEP (0.01% for N and Na, 0.05% for C, 0.08% for Mg and 1.98 μg g(-1) for P). Comparison of predicted macronutrients with reference standards using a one-way ANOVA test showed no statistical difference at 95% confidence level. To the best of the authors' knowledge, this is the first time that an XRF method has demonstrated utility in trace analysis of macronutrients in soil or related matrices. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Comparison of Cryopreserved Human Sperm between Ultra Rapid Freezing and Slow Programmable Freezing: Effect on Motility, Morphology and DNA Integrity.

    PubMed

    Tongdee, Pattama; Sukprasert, Matchuporn; Satirapod, Chonticha; Wongkularb, Anna; Choktanasiri, Wicham

    2015-05-01

    Cryopreservation of sperm is common methods to preserve male fertility. Sperm freezing, suggest slow programmable freezing caused lower change of sperm morphology than sperm freezing in vapor of liquid nitrogen. Ultra rapid freezing is easy to be worked on, less time, low cost and does not need high experience. To compare the effect on sperm motility, morphology and DNA integrity of post-thawed sperm after ultra rapid freezing and slow programmable freezing methods. Experimental study at laboratory of infertility unit, Department of Obstetrics and Gynecology, Faculty of Medicine Ramathibodi Hospital. Thirty-seven semen samples with normal semen analysis according to World Health Organization (WHO) 1999 [normal sperm volume ( 2 ml) and normal sperm concentration (≥ 20 x10(6)/ml) and sperm motility (≥ 50%)]. Semen samples were washed. Then each semen sample was divided into six cryovials. Two cryovials, 0.5 ml each, were cryopreserved by slow programmable freezing. Four 0.25 ml containing cryovials, were cryopreserved by ultra rapidfreezing method. After cryopreservationfor 1 month, thawedprocess was carried out at room temperature. Main outcomes are sperm motility was determined by Computer-Assisted Semen Analysis (CASA), sperm morphology was determined by eosin-methylene blue staining and sperm DNA integrity was assessed by TUNEL assay. Sperm motility was reduced significantly by both methods, from 70.4 (9.0)% to 29.1 (12.3)% in slowprogrammable freezing and to 19.7 (9.8)% in ultra rapid freezing (p < 0.05). Sperm motility decreased significantly more by ultra rapid freezing (p < 0.001). The percentage of normal sperm morphology and DNA integrity were also reduced significantly by both methods. However, no significant difference between the two methods was found (p > 0.05). Cryopreservation of human sperm for 1 month significantly decreased sperm motility, morphology and DNA integrity in both methods. However sperm motility was decreased more by ultra rapid freezing.

  10. Appraisal and standardization of curvilinear velocity (VCL) cut-off values for CASA analysis of Japanese quail (Coturnix japonica) sperm.

    PubMed

    Farooq, U; Malecki, I A; Mahmood, M; Martin, G B

    2017-06-01

    One of the basic steps in objective analysis of sperm motility is the subdivision of a motile sperm population into slow, medium and rapid categories based on their velocity. However, for CASA analysis of quail sperm, the velocity values for categorization of slow, medium and rapid sperm have not yet been standardized. To identify the cut-off values of "velocity curvilinear" (VCL) for quail sperm categorization, we captured and analysed 22,300 tracks of quail sperm using SCA ® -CASA. The median and mean VCL values were 85 and 97 μm/s. To define the VCL cut-off values, we used two methods. In the first, we identified the upper (rapid sperm) and lower (slow sperm) cut-off values using: (i) median VCL ± 25% or ± 50% or ± 75% of median VCL value; (ii) first and third quartile values of VCL data (i.e. 25% cut-off setting); and (iii) 33% and 66% of VCL data. Among these settings, sperm categories and their corresponding motility characteristics recorded using the "25%" setting (i.e. slow ≤36 ≤ medium ≤154 ≤ rapid) were found the most realistic and coherent with male ranking by fertility. In the second method, we calculated heteroscedasticity in the total VCL data using PCA and the two-step clustering method. With this approach, the mean of the high and low clusters was 165 and 51 μm/s, respectively. Together, the mean from two methods suggested that, for SCA ® -CASA categorization of quail sperm, sperm should be classed as "rapid" at VCL ≥160 μm/s and "slow" at VCL ≤45 μm/s. © 2017 Blackwell Verlag GmbH.

  11. Operation Guiding Light-Scientific Program and Field Plan. The Pilot Field Experiment for NORDA Project Chemical Dynamics in Ocean Frontal Areas

    DTIC Science & Technology

    1985-03-01

    distribution. Samples of suspended partici’lates will also be collected for later image and elemental analysis . 25 Method of analysis for particle...will be flow injection analysis . This method will allow rapid, continuous analysis of seawater nutrients. Measurements will be made at one minute...5 m intervals) as well as from the underway pumping system. Method of pigment analysis for porphyrin and carotenoid pigments will be separation by

  12. SIMS: A Hybrid Method for Rapid Conformational Analysis

    PubMed Central

    Gipson, Bryant; Moll, Mark; Kavraki, Lydia E.

    2013-01-01

    Proteins are at the root of many biological functions, often performing complex tasks as the result of large changes in their structure. Describing the exact details of these conformational changes, however, remains a central challenge for computational biology due the enormous computational requirements of the problem. This has engendered the development of a rich variety of useful methods designed to answer specific questions at different levels of spatial, temporal, and energetic resolution. These methods fall largely into two classes: physically accurate, but computationally demanding methods and fast, approximate methods. We introduce here a new hybrid modeling tool, the Structured Intuitive Move Selector (sims), designed to bridge the divide between these two classes, while allowing the benefits of both to be seamlessly integrated into a single framework. This is achieved by applying a modern motion planning algorithm, borrowed from the field of robotics, in tandem with a well-established protein modeling library. sims can combine precise energy calculations with approximate or specialized conformational sampling routines to produce rapid, yet accurate, analysis of the large-scale conformational variability of protein systems. Several key advancements are shown, including the abstract use of generically defined moves (conformational sampling methods) and an expansive probabilistic conformational exploration. We present three example problems that sims is applied to and demonstrate a rapid solution for each. These include the automatic determination of “active” residues for the hinge-based system Cyanovirin-N, exploring conformational changes involving long-range coordinated motion between non-sequential residues in Ribose-Binding Protein, and the rapid discovery of a transient conformational state of Maltose-Binding Protein, previously only determined by Molecular Dynamics. For all cases we provide energetic validations using well-established energy fields, demonstrating this framework as a fast and accurate tool for the analysis of a wide range of protein flexibility problems. PMID:23935893

  13. Rapid optimization of tension distribution for cable-driven parallel manipulators with redundant cables

    NASA Astrophysics Data System (ADS)

    Ouyang, Bo; Shang, Weiwei

    2016-03-01

    The solution of tension distributions is infinite for cable-driven parallel manipulators(CDPMs) with redundant cables. A rapid optimization method for determining the optimal tension distribution is presented. The new optimization method is primarily based on the geometry properties of a polyhedron and convex analysis. The computational efficiency of the optimization method is improved by the designed projection algorithm, and a fast algorithm is proposed to determine which two of the lines are intersected at the optimal point. Moreover, a method for avoiding the operating point on the lower tension limit is developed. Simulation experiments are implemented on a six degree-of-freedom(6-DOF) CDPM with eight cables, and the results indicate that the new method is one order of magnitude faster than the standard simplex method. The optimal distribution of tension distribution is thus rapidly established on real-time by the proposed method.

  14. Rapid qualitative and quantitative analysis of proanthocyanidin oligomers and polymers by UPLC-MS/MS

    USDA-ARS?s Scientific Manuscript database

    Proanthocyanidins (PAs) are a structurally complex and bioactive group of tannins. Detailed analysis of PA concentration, composition, and structure typically requires the use of one or more time-consuming analytical methods. For example, the commonly employed thiolysis and phloroglucinolysis method...

  15. A method for rapid quantitative assessment of biofilms with biomolecular staining and image analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larimer, Curtis J.; Winder, Eric M.; Jeters, Robert T.

    Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results weremore » compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.« less

  16. A method for rapid quantitative assessment of biofilms with biomolecular staining and image analysis

    DOE PAGES

    Larimer, Curtis J.; Winder, Eric M.; Jeters, Robert T.; ...

    2015-12-07

    Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results weremore » compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.« less

  17. Rapid is relative until clearly defined: A response to Kleindl et al.

    EPA Science Inventory

    The response to Kleindl et al. replies to their claims that an analysis of rapid assessments published in an Environmental Protection Agency report and then in the peer-reviewed journal, Wetlands, wrongly eliminated the Hydrogeomorphic Assessment Method (HGM) from consideration. ...

  18. [Study on rapid determination and analysis of rocket kerosene by near infrared spectrum and chemometrics].

    PubMed

    Xia, Ben-Li; Cong, Ji-Xin; Li, Xia; Wang, Xuan-Jun

    2011-06-01

    The rocket kerosene quality properties such as density, distillation range, viscosity and iodine value were successfully measured based on their near-infrared spectrum (NIRS) and chemometrics. In the present paper, more than 70 rocket kerosene samples were determined by near infrared spectrum, the models were built using the partial least squares method within the appropriate wavelength range. The correlation coefficients (R2) of every rocket kerosene's quality properties ranged from 0.862 to 0.999. Ten unknown samples were determined with the model, and the result showed that the prediction accuracy of near infrared spectrum method accords with standard analysis requirements. The new method is well suitable for replacing the traditional standard method to rapidly determine the properties of the rocket kerosene.

  19. Validated flow-injection method for rapid aluminium determination in anti-perspirants.

    PubMed

    López-Gonzálvez, A; Ruiz, M A; Barbas, C

    2008-09-29

    A flow-injection (FI) method for the rapid determination of aluminium in anti-perspirants has been developed. The method is based on the spectrophotometric detection at 535nm of the complex formed between Al ions and the chromogenic reagent eriochrome cyanine R. Both the batch and FI methods were validated by checking the parameters included in the ISO-3543-1 regulation. Variables involved in the FI method were optimized by using appropriate statistical tools. The method does not exhibit interference from other substances present in anti-perspirants and it shows a high precision with a R.S.D. value (n=6) of 0.9%. Moreover, the accuracy of the method was evaluated by comparison with a back complexometric titration method, which is currently used for routine analysis in pharmaceutical laboratories. The Student's t-test showed that the results obtained by both methods were not significantly different for a significance level of 95%. A response time of 12s and a sample analysis time, by performing triplicate injections, of 60s were achieved. The analytical figures of merit make the method highly appropriate to substitute the time-consuming complexometric method for this kind of analysis.

  20. Microlensing observations rapid search for exoplanets: MORSE code for GPUs

    NASA Astrophysics Data System (ADS)

    McDougall, Alistair; Albrow, Michael D.

    2016-02-01

    The rapid analysis of ongoing gravitational microlensing events has been integral to the successful detection and characterization of cool planets orbiting low-mass stars in the Galaxy. In this paper, we present an implementation of search and fit techniques on graphical processing unit (GPU) hardware. The method allows for the rapid identification of candidate planetary microlensing events and their subsequent follow-up for detailed characterization.

  1. Expediting evidence synthesis for healthcare decision-making: exploring attitudes and perceptions towards rapid reviews using Q methodology

    PubMed Central

    Moher, David; Clifford, Tammy J.

    2016-01-01

    Background Rapid reviews expedite the knowledge synthesis process with the goal of providing timely information to healthcare decision-makers who want to use evidence-informed policy and practice approaches. A range of opinions and viewpoints on rapid reviews is thought to exist; however, no research to date has formally captured these views. This paper aims to explore evidence producer and knowledge user attitudes and perceptions towards rapid reviews. Methods A Q methodology study was conducted to identify central viewpoints about rapid reviews based on a broad topic discourse. Participants rank-ordered 50 text statements and explained their Q-sort in free-text comments. Individual Q-sorts were analysed using Q-Assessor (statistical method: factor analysis with varimax rotation). Factors, or salient viewpoints on rapid reviews, were identified, interpreted and described. Results Analysis of the 11 individual Q sorts identified three prominent viewpoints: Factor A cautions against the use of study design labels to make judgements. Factor B maintains that rapid reviews should be the exception and not the rule. Factor C focuses on the practical needs of the end-user over the review process. Conclusion Results show that there are opposing viewpoints on rapid reviews, yet some unity exists. The three factors described offer insight into how and why various stakeholders act as they do and what issues may need to be resolved before increase uptake of the evidence from rapid reviews can be realized in healthcare decision-making environments. PMID:27761324

  2. Rapid Method for Sodium Hydroxide Fusion of Concrete and ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Americium-241, plutonium-238, plutonium-239, radium-226, strontium-90, uranium-234, uranium-235 and uranium-238 in concrete and brick samples Method Selected for: SAM lists this method for qualitative analysis of americium-241, plutonium-238, plutonium-239, radium-226, strontium-90, uranium-234, uranium-235 and uranium-238 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  3. Analysis and quantitation of volatile organic compounds emitted from plastics used in museum construction by evolved gas analysis-gas chromatography-mass spectrometry.

    PubMed

    Samide, Michael J; Smith, Gregory D

    2015-12-24

    Construction materials used in museums for the display, storage, and transportation of artwork must be assessed for their tendency to emit harmful pollution that could potentially damage cultural treasures. Traditionally, a subjective metals corrosion test known as the Oddy test has been widely utilized in museums for this purpose. To augment the Oddy test, an instrumental sampling approach based on evolved gas analysis (EGA) coupled to gas chromatography (GC) with mass spectral (MS) detection has been implemented for the first time to qualitatively identify off-gassed pollutants under specific conditions. This approach is compared to other instrumental methods reported in the literature. This novel application of the EGA sampling technique yields several benefits over traditional testing, including rapidity, high sensitivity, and broad detectability of volatile organic compounds (VOCs). Furthermore, unlike other reported instrumental approaches, the EGA method was used to determine quantitatively the amount of VOCs emitted by acetate resins and polyurethane foams under specific conditions using both an external calibration method as well as surrogate response factors. EGA was successfully employed to rapidly characterize emissions from 12 types of common plastics. This analysis is advocated as a rapid pre-screening method to rule out poorly performing materials prior to investing time and energy in Oddy testing. The approach is also useful for rapid, routine testing of construction materials previously vetted by traditional testing, but which may experience detrimental formulation changes over time. As an example, a case study on batch re-orders of rigid expanded poly(vinyl chloride) board stock is presented. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Protoplast isolation, transient transformation of leaf mesophyll protoplasts and improved Agrobacterium-mediated leaf disc infiltration of Phaseolus vulgaris: tools for rapid gene expression analysis.

    PubMed

    Nanjareddy, Kalpana; Arthikala, Manoj-Kumar; Blanco, Lourdes; Arellano, Elizabeth S; Lara, Miguel

    2016-06-24

    Phaseolus vulgaris is one of the most extensively studied model legumes in the world. The P. vulgaris genome sequence is available; therefore, the need for an efficient and rapid transformation system is more imperative than ever. The functional characterization of P. vulgaris genes is impeded chiefly due to the non-amenable nature of Phaseolus sp. to stable genetic transformation. Transient transformation systems are convenient and versatile alternatives for rapid gene functional characterization studies. Hence, the present work focuses on standardizing methodologies for protoplast isolation from multiple tissues and transient transformation protocols for rapid gene expression analysis in the recalcitrant grain legume P. vulgaris. Herein, we provide methodologies for the high-throughput isolation of leaf mesophyll-, flower petal-, hypocotyl-, root- and nodule-derived protoplasts from P. vulgaris. The highly efficient polyethylene glycol-mannitol magnesium (PEG-MMG)-mediated transformation of leaf mesophyll protoplasts was optimized using a GUS reporter gene. We used the P. vulgaris SNF1-related protein kinase 1 (PvSnRK1) gene as proof of concept to demonstrate rapid gene functional analysis. An RT-qPCR analysis of protoplasts that had been transformed with PvSnRK1-RNAi and PvSnRK1-OE vectors showed the significant downregulation and ectopic constitutive expression (overexpression), respectively, of the PvSnRK1 transcript. We also demonstrated an improved transient transformation approach, sonication-assisted Agrobacterium-mediated transformation (SAAT), for the leaf disc infiltration of P. vulgaris. Interestingly, this method resulted in a 90 % transformation efficiency and transformed 60-85 % of the cells in a given area of the leaf surface. The constitutive expression of YFP further confirmed the amenability of the system to gene functional characterization studies. We present simple and efficient methodologies for protoplast isolation from multiple P. vulgaris tissues. We also provide a high-efficiency and amenable method for leaf mesophyll transformation for rapid gene functional characterization studies. Furthermore, a modified SAAT leaf disc infiltration approach aids in validating genes and their functions. Together, these methods help to rapidly unravel novel gene functions and are promising tools for P. vulgaris research.

  5. Evaluation of methods for rapid determination of freezing point of aviation fuels

    NASA Technical Reports Server (NTRS)

    Mathiprakasam, B.

    1982-01-01

    Methods for identification of the more promising concepts for the development of a portable instrument to rapidly determine the freezing point of aviation fuels are described. The evaluation process consisted of: (1) collection of information on techniques previously used for the determination of the freezing point, (2) screening and selection of these techniques for further evaluation of their suitability in a portable unit for rapid measurement, and (3) an extensive experimental evaluation of the selected techniques and a final selection of the most promising technique. Test apparatuses employing differential thermal analysis and the change in optical transparency during phase change were evaluated and tested. A technique similar to differential thermal analysis using no reference fuel was investigated. In this method, the freezing point was obtained by digitizing the data and locating the point of inflection. Results obtained using this technique compare well with those obtained elsewhere using different techniques. A conceptual design of a portable instrument incorporating this technique is presented.

  6. Rapid Identification of Sequences for Orphan Enzymes to Power Accurate Protein Annotation

    PubMed Central

    Ojha, Sunil; Watson, Douglas S.; Bomar, Martha G.; Galande, Amit K.; Shearer, Alexander G.

    2013-01-01

    The power of genome sequencing depends on the ability to understand what those genes and their proteins products actually do. The automated methods used to assign functions to putative proteins in newly sequenced organisms are limited by the size of our library of proteins with both known function and sequence. Unfortunately this library grows slowly, lagging well behind the rapid increase in novel protein sequences produced by modern genome sequencing methods. One potential source for rapidly expanding this functional library is the “back catalog” of enzymology – “orphan enzymes,” those enzymes that have been characterized and yet lack any associated sequence. There are hundreds of orphan enzymes in the Enzyme Commission (EC) database alone. In this study, we demonstrate how this orphan enzyme “back catalog” is a fertile source for rapidly advancing the state of protein annotation. Starting from three orphan enzyme samples, we applied mass-spectrometry based analysis and computational methods (including sequence similarity networks, sequence and structural alignments, and operon context analysis) to rapidly identify the specific sequence for each orphan while avoiding the most time- and labor-intensive aspects of typical sequence identifications. We then used these three new sequences to more accurately predict the catalytic function of 385 previously uncharacterized or misannotated proteins. We expect that this kind of rapid sequence identification could be efficiently applied on a larger scale to make enzymology’s “back catalog” another powerful tool to drive accurate genome annotation. PMID:24386392

  7. Rapid identification of sequences for orphan enzymes to power accurate protein annotation.

    PubMed

    Ramkissoon, Kevin R; Miller, Jennifer K; Ojha, Sunil; Watson, Douglas S; Bomar, Martha G; Galande, Amit K; Shearer, Alexander G

    2013-01-01

    The power of genome sequencing depends on the ability to understand what those genes and their proteins products actually do. The automated methods used to assign functions to putative proteins in newly sequenced organisms are limited by the size of our library of proteins with both known function and sequence. Unfortunately this library grows slowly, lagging well behind the rapid increase in novel protein sequences produced by modern genome sequencing methods. One potential source for rapidly expanding this functional library is the "back catalog" of enzymology--"orphan enzymes," those enzymes that have been characterized and yet lack any associated sequence. There are hundreds of orphan enzymes in the Enzyme Commission (EC) database alone. In this study, we demonstrate how this orphan enzyme "back catalog" is a fertile source for rapidly advancing the state of protein annotation. Starting from three orphan enzyme samples, we applied mass-spectrometry based analysis and computational methods (including sequence similarity networks, sequence and structural alignments, and operon context analysis) to rapidly identify the specific sequence for each orphan while avoiding the most time- and labor-intensive aspects of typical sequence identifications. We then used these three new sequences to more accurately predict the catalytic function of 385 previously uncharacterized or misannotated proteins. We expect that this kind of rapid sequence identification could be efficiently applied on a larger scale to make enzymology's "back catalog" another powerful tool to drive accurate genome annotation.

  8. Rapid test for the detection of hazardous microbiological material

    NASA Astrophysics Data System (ADS)

    Mordmueller, Mario; Bohling, Christian; John, Andreas; Schade, Wolfgang

    2009-09-01

    After attacks with anthrax pathogens have been committed since 2001 all over the world the fast detection and determination of biological samples has attracted interest. A very promising method for a rapid test is Laser Induced Breakdown Spectroscopy (LIBS). LIBS is an optical method which uses time-resolved or time-integrated spectral analysis of optical plasma emission after pulsed laser excitation. Even though LIBS is well established for the determination of metals and other inorganic materials the analysis of microbiological organisms is difficult due to their very similar stoichiometric composition. To analyze similar LIBS-spectra computer assisted chemometrics is a very useful approach. In this paper we report on first results of developing a compact and fully automated rapid test for the detection of hazardous microbiological material. Experiments have been carried out with two setups: A bulky one which is composed of standard laboratory components and a compact one consisting of miniaturized industrial components. Both setups work at an excitation wavelength of λ=1064nm (Nd:YAG). Data analysis is done by Principal Component Analysis (PCA) with an adjacent neural network for fully automated sample identification.

  9. Rapid Assessment of Genotoxicity by Flow Cytometric Detection of Cell Cycle Alterations.

    PubMed

    Bihari, Nevenka

    2017-01-01

    Flow cytometry is a convenient method for the determination of genotoxic effects of environmental pollution and can reveal genotoxic compounds in unknown environmental mixtures. It is especially suitable for the analyses of large numbers of samples during monitoring programs. The speed of detection is one of the advantages of this technique which permits the acquisition of 10 4 -10 5 cells per sample in 5 min. This method can rapidly detect cell cycle alterations resulting from DNA damage. The outcome of such an analysis is a diagram of DNA content across the cell cycle which indicates cell proliferation, G 2 arrests, G 1 delays, apoptosis, and ploidy.Here, we present the flow cytometric procedure for rapid assessment of genotoxicity via detection of cell cycle alterations. The described protocol simplifies the analysis of genotoxic effects in marine environments and is suitable for monitoring purposes. It uses marine mussel cells in the analysis and can be adapted to investigations on a broad range of marine invertebrates.

  10. Rapid sample preparation and fast GC-MS/MS for the analysis of pesticides and environmental contaminants in fish

    USDA-ARS?s Scientific Manuscript database

    A rapid high-throughput analytical method for the simultaneous determination of pesticides and environmental contaminants, including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and flame retardants (FRs) in fish was developed and ...

  11. A scoping review of rapid review methods.

    PubMed

    Tricco, Andrea C; Antony, Jesmin; Zarin, Wasifa; Strifler, Lisa; Ghassemi, Marco; Ivory, John; Perrier, Laure; Hutton, Brian; Moher, David; Straus, Sharon E

    2015-09-16

    Rapid reviews are a form of knowledge synthesis in which components of the systematic review process are simplified or omitted to produce information in a timely manner. Although numerous centers are conducting rapid reviews internationally, few studies have examined the methodological characteristics of rapid reviews. We aimed to examine articles, books, and reports that evaluated, compared, used or described rapid reviews or methods through a scoping review. MEDLINE, EMBASE, the Cochrane Library, internet websites of rapid review producers, and reference lists were searched to identify articles for inclusion. Two reviewers independently screened literature search results and abstracted data from included studies. Descriptive analysis was conducted. We included 100 articles plus one companion report that were published between 1997 and 2013. The studies were categorized as 84 application papers, seven development papers, six impact papers, and four comparison papers (one was included in two categories). The rapid reviews were conducted between 1 and 12 months, predominantly in Europe (58 %) and North America (20 %). The included studies failed to report 6 % to 73 % of the specific systematic review steps examined. Fifty unique rapid review methods were identified; 16 methods occurred more than once. Streamlined methods that were used in the 82 rapid reviews included limiting the literature search to published literature (24 %) or one database (2 %), limiting inclusion criteria by date (68 %) or language (49 %), having one person screen and another verify or screen excluded studies (6 %), having one person abstract data and another verify (23 %), not conducting risk of bias/quality appraisal (7 %) or having only one reviewer conduct the quality appraisal (7 %), and presenting results as a narrative summary (78 %). Four case studies were identified that compared the results of rapid reviews to systematic reviews. Three studies found that the conclusions between rapid reviews and systematic reviews were congruent. Numerous rapid review approaches were identified and few were used consistently in the literature. Poor quality of reporting was observed. A prospective study comparing the results from rapid reviews to those obtained through systematic reviews is warranted.

  12. A homotopy analysis method for the nonlinear partial differential equations arising in engineering

    NASA Astrophysics Data System (ADS)

    Hariharan, G.

    2017-05-01

    In this article, we have established the homotopy analysis method (HAM) for solving a few partial differential equations arising in engineering. This technique provides the solutions in rapid convergence series with computable terms for the problems with high degree of nonlinear terms appearing in the governing differential equations. The convergence analysis of the proposed method is also discussed. Finally, we have given some illustrative examples to demonstrate the validity and applicability of the proposed method.

  13. Rapid Method for Sodium Hydroxide Fusion of Asphalt ...

    EPA Pesticide Factsheets

    Technical Brief--Addendum to Selected Analytical Methods (SAM) 2012 The method will be used for qualitative analysis of americium-241, plutonium-238, plutonium-239, radium-226, strontium-90, uranium-234, uranium-235 and uranium-238 in asphalt matrices samples.

  14. An efficient and rapid transgenic pollen screening and detection method using flow cytometry.

    PubMed

    Moon, Hong S; Eda, Shigetoshi; Saxton, Arnold M; Ow, David W; Stewart, C Neal

    2011-01-01

    Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.

  15. Nontargeted, Rapid Screening of Extra Virgin Olive Oil Products for Authenticity Using Near-Infrared Spectroscopy in Combination with Conformity Index and Multivariate Statistical Analyses.

    PubMed

    Karunathilaka, Sanjeewa R; Kia, Ali-Reza Fardin; Srigley, Cynthia; Chung, Jin Kyu; Mossoba, Magdi M

    2016-10-01

    A rapid tool for evaluating authenticity was developed and applied to the screening of extra virgin olive oil (EVOO) retail products by using Fourier-transform near infrared (FT-NIR) spectroscopy in combination with univariate and multivariate data analysis methods. Using disposable glass tubes, spectra for 62 reference EVOO, 10 edible oil adulterants, 20 blends consisting of EVOO spiked with adulterants, 88 retail EVOO products and other test samples were rapidly measured in the transmission mode without any sample preparation. The univariate conformity index (CI) and the multivariate supervised soft independent modeling of class analogy (SIMCA) classification tool were used to analyze the various olive oil products which were tested for authenticity against a library of reference EVOO. Better discrimination between the authentic EVOO and some commercial EVOO products was observed with SIMCA than with CI analysis. Approximately 61% of all EVOO commercial products were flagged by SIMCA analysis, suggesting that further analysis be performed to identify quality issues and/or potential adulterants. Due to its simplicity and speed, FT-NIR spectroscopy in combination with multivariate data analysis can be used as a complementary tool to conventional official methods of analysis to rapidly flag EVOO products that may not belong to the class of authentic EVOO. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  16. Note: Non-invasive optical method for rapid determination of alignment degree of oriented nanofibrous layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokorny, M.; Rebicek, J.; Klemes, J.

    2015-10-15

    This paper presents a rapid non-destructive method that provides information on the anisotropic internal structure of nanofibrous layers. A laser beam of a wavelength of 632.8 nm is directed at and passes through a nanofibrous layer prepared by electrostatic spinning. Information about the structural arrangement of nanofibers in the layer is directly visible in the form of a diffraction image formed on a projection screen or obtained from measured intensities of the laser beam passing through the sample which are determined by the dependency of the angle of the main direction of polarization of the laser beam on the axismore » of alignment of nanofibers in the sample. Both optical methods were verified on Polyvinyl alcohol (PVA) nanofibrous layers (fiber diameter of 470 nm) with random, single-axis aligned and crossed structures. The obtained results match the results of commonly used methods which apply the analysis of electron microscope images. The presented simple method not only allows samples to be analysed much more rapidly and without damaging them but it also makes possible the analysis of much larger areas, up to several square millimetres, at the same time.« less

  17. Mycotoxin analysis: an update.

    PubMed

    Krska, Rudolf; Schubert-Ullrich, Patricia; Molinelli, Alexandra; Sulyok, Michael; MacDonald, Susan; Crews, Colin

    2008-02-01

    Mycotoxin contamination of cereals and related products used for feed can cause intoxication, especially in farm animals. Therefore, efficient analytical tools for the qualitative and quantitative analysis of toxic fungal metabolites in feed are required. Current methods usually include an extraction step, a clean-up step to reduce or eliminate unwanted co-extracted matrix components and a separation step with suitably specific detection ability. Quantitative methods of analysis for most mycotoxins use immunoaffinity clean-up with high-performance liquid chromatography (HPLC) separation in combination with UV and/or fluorescence detection. Screening of samples contaminated with mycotoxins is frequently performed by thin layer chromatography (TLC), which yields qualitative or semi-quantitative results. Nowadays, enzyme-linked immunosorbent assays (ELISA) are often used for rapid screening. A number of promising methods, such as fluorescence polarization immunoassays, dipsticks, and even newer methods such as biosensors and non-invasive techniques based on infrared spectroscopy, have shown great potential for mycotoxin analysis. Currently, there is a strong trend towards the use of multi-mycotoxin methods for the simultaneous analysis of several of the important Fusarium mycotoxins, which is best achieved by LC-MS/MS (liquid chromatography with tandem mass spectrometry). This review focuses on recent developments in the determination of mycotoxins with a special emphasis on LC-MS/MS and emerging rapid methods.

  18. Gene Scanning of an Internalin B Gene Fragment Using High-Resolution Melting Curve Analysis as a Tool for Rapid Typing of Listeria monocytogenes

    PubMed Central

    Pietzka, Ariane T.; Stöger, Anna; Huhulescu, Steliana; Allerberger, Franz; Ruppitsch, Werner

    2011-01-01

    The ability to accurately track Listeria monocytogenes strains involved in outbreaks is essential for control and prevention of listeriosis. Because current typing techniques are time-consuming, cost-intensive, technically demanding, and difficult to standardize, we developed a rapid and cost-effective method for typing of L. monocytogenes. In all, 172 clinical L. monocytogenes isolates and 20 isolates from culture collections were typed by high-resolution melting (HRM) curve analysis of a specific locus of the internalin B gene (inlB). All obtained HRM curve profiles were verified by sequence analysis. The 192 tested L. monocytogenes isolates yielded 15 specific HRM curve profiles. Sequence analysis revealed that these 15 HRM curve profiles correspond to 18 distinct inlB sequence types. The HRM curve profiles obtained correlated with the five phylogenetic groups I.1, I.2, II.1, II.2, and III. Thus, HRM curve analysis constitutes an inexpensive assay and represents an improvement in typing relative to classical serotyping or multiplex PCR typing protocols. This method provides a rapid and powerful screening tool for simultaneous preliminary typing of up to 384 samples in approximately 2 hours. PMID:21227395

  19. Rapid In Situ Profiling of Lipid C═C Location Isomers in Tissue Using Ambient Mass Spectrometry with Photochemical Reactions.

    PubMed

    Tang, Fei; Guo, Chengan; Ma, Xiaoxiao; Zhang, Jian; Su, Yuan; Tian, Ran; Shi, Riyi; Xia, Yu; Wang, Xiaohao; Ouyang, Zheng

    2018-05-01

    Rapid and in situ profiling of lipids using ambient mass spectrometry (AMS) techniques has great potential for clinical diagnosis, biological studies, and biomarker discovery. In this study, the online photochemical reaction involving carbon-carbon double bonds was coupled with a surface sampling technique to develop a direct tissue-analysis method with specificity to lipid C═C isomers. This method enabled the in situ analysis of lipids from the surface of various tissues or tissue sections, which allowed the structural characterization of lipid isomers within 2 min. Under optimized reaction conditions, we have established a method for the relative quantitation of lipid C═C location isomers by comparing the abundances of the diagnostic ions arising from each isomer, which has been proven effective through the established linear relationship ( R 2 = 0.999) between molar ratio and diagnostic ion ratio of the FA 18:1 C═C location isomers. This method was then used for the rapid profiling of unsaturated lipid C═C isomers in the sections of rat brain, lung, liver, spleen, and kidney, as well as in normal and diseased rat tissues. Quantitative information on FA 18:1 and PC 16:0-18:1 C═C isomers was obtained, and significant differences were observed between different samples. To the best of our knowledge, this is the first study to report the direct analysis of lipid C═C isomers in tissues using AMS. Our results demonstrated that this method can serve as a rapid analytical approach for the profiling of unsaturated lipid C═C isomers in biological tissues and should contribute to functional lipidomics and clinical diagnosis.

  20. Rapid Detection and Identification of Human Hookworm Infections through High Resolution Melting (HRM) Analysis

    PubMed Central

    Ngui, Romano; Lim, Yvonne A. L.; Chua, Kek Heng

    2012-01-01

    Background Hookworm infections are still endemic in low and middle income tropical countries with greater impact on the socioeconomic and public health of the bottom billion of the world's poorest people. In this study, a real-time polymerase chain reaction (PCR) coupled with high resolution melting-curve (HRM) analysis was evaluated for an accurate, rapid and sensitive tool for species identification focusing on the five human hookworm species. Methods Real-time PCR coupled with HRM analysis targeting the second internal transcribed spacer (ITS-2) of nuclear ribosomal DNA as the genetic marker was used to identify and distinguish hookworm species in human samples. Unique and distinct characteristics of HRM patterns were produced for each of the five hookworm species. The melting curves were characterized by peaks of 79.24±0.05°C and 83.00±0.04°C for Necator americanus, 79.12±0.10°C for Ancylostoma duodenale, 79.40±0.10°C for Ancylostoma ceylanicum, 79.63±0.05°C for Ancylostoma caninum and 79.70±0.14°C for Ancylostoma braziliense. An evaluation of the method's sensitivity and specificity revealed that this assay was able to detect as low as 0.01 ng/µl hookworm DNA and amplification was only recorded for hookworm positive samples. Conclusion The HRM assay developed in this study is a rapid and straightforward method for the diagnosis, identification and discrimination of five human hookworms. This assay is simple compared to other probe-based genotyping methods as it does not require multiplexing, DNA sequencing or post-PCR processing. Therefore, this method offers a new alternative for rapid detection of human hookworm species. PMID:22844538

  1. Analysis of flavor compounds by GC/MS after liquid-liquid extraction from fruit juices

    NASA Astrophysics Data System (ADS)

    Tuşa, F. D.; Moldovan, Z.; Schmutzer, G.; Magdaş, D. A.; Dehelean, A.; Vlassa, M.

    2012-02-01

    In this work we describe a rapid method for analysis of volatile profiles of several commercial fruit juices using GC/MS instrument after liquid-liquid extraction. Volatile flavor compounds have been identified based on mass spectrum obtained in EI mode. This method allows to analyses a wide range of flavor compounds (esters, aldehydes, alcohols, terpenoids) the procedure was rapid, simple and inexpensive. Moreover, by means of volatile compounds it could be possible to distinguish between juices of organic and conventional production and those with flavorings addition. More of 20 compounds were identified and quantified as relative chromatogram area taken on larges ion in mass spectrum.

  2. Rapid economic analysis of northern hardwood stand improvement options

    Treesearch

    William B. Leak

    1980-01-01

    Data and methodology are provided for projecting basal area, diameter, volumes, and values by product for northern hardwood stands, and for determining the rate of return on stand improvement investments. The method is rapid, requires a minimum amount of information, and should prove useful for on-the-ground economic analyses.

  3. Nondestructive NIR reflectance spectroscopic method for rapid fatty acid analysis of peanut seeds

    USDA-ARS?s Scientific Manuscript database

    NIR reflectance spectroscopy was used to analyze the fatty acid concentration present in breeder's peanut seeds samples, rapidly and nondestructively. Absorbance spectra were collected in the wavelength range from 400 nm to 2500 nm using a NIR spectrometer. Fatty acids, oleic, linoleic and palmitic ...

  4. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be < 4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  5. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    PubMed

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be <4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Analysis of cocoa flavanols and procyanidins (DP 1-10) in cocoa-containing ingredients and products by rapid resolution liquid chromatography: single-laboratory validation.

    PubMed

    Machonis, Philip R; Jones, Matthew A; Kwik-Uribe, Catherine

    2014-01-01

    Recently, a multilaboratory validation (MLV) of AOAC Official Method 2012.24 for the determination of cocoa flavanols and procyanidins (CF-CP) in cocoa-based ingredients and products determined that the method was robust, reliable, and transferrable. Due to the complexity of the CF-CP molecules, this method required a run time exceeding 1 h to achieve acceptable separations. To address this issue, a rapid resolution normal phase LC method was developed, and a single-laboratory validation (SLV) study conducted. Flavanols and procyanidins with a degree of polymerization (DP) up to 10 were eluted in 15 min using a binary gradient applied to a diol stationary phase, detected using fluorescence detection, and reported as a total sum of DP 1-10. Quantification was achieved using (-)-epicatechin-based relative response factors for DP 2-10. Spike recovery samples and seven different types of cocoa-based samples were analyzed to evaluate the accuracy, precision, LOD, LOQ, and linearity of the method. The within-day precision of the reported content for the samples was 1.15-5.08%, and overall precision was 3.97-13.61%. Spike-recovery experiments demonstrated recoveries of over 98%. The results of this SLV were compared to those previously obtained in the MLV and found to be consistent. The translation to rapid resolution LC allowed for an 80% reduction in analysis time and solvent usage, while retaining the accuracy and reliability of the original method. The savings in both cost and time of this rapid method make it well-suited for routine laboratory use.

  7. Guilty by dissociation-development of gas chromatography-mass spectrometry (GC-MS) and other rapid screening methods for the analysis of 13 diphenidine-derived new psychoactive substances (NPSs).

    PubMed

    Geyer, Pierre M; Hulme, Matthew C; Irving, Joseph P B; Thompson, Paul D; Ashton, Ryan N; Lee, Robert J; Johnson, Lucy; Marron, Jack; Banks, Craig E; Sutcliffe, Oliver B

    2016-11-01

    The prevalence of new psychoactive substances (NPSs) in forensic casework has increased prominently in recent years. This has given rise to significant legal and analytical challenges in the identification of these substances. The requirement for validated, robust and rapid testing methodologies for these compounds is obvious. This study details the analysis of 13 synthesised diphenidine derivatives encountered in casework using presumptive testing, thin layer chromatography and gas chromatography-mass spectrometry (GC-MS). Specifically, the validated GC-MS method provides, for the first time, both a general screening method and quantification of the active components for seized solid samples, both in their pure form and in the presence of common adulterants. Graphical Abstract Chemical synthesis and forensic analysis of 13 diphenidine-derived new psychoactive substance(s).

  8. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy.

    PubMed

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories.

  9. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy

    PubMed Central

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818

  10. Rapid analysis of pharmaceutical drugs using LIBS coupled with multivariate analysis.

    PubMed

    Tiwari, P K; Awasthi, S; Kumar, R; Anand, R K; Rai, P K; Rai, A K

    2018-02-01

    Type 2 diabetes drug tablets containing voglibose having dose strengths of 0.2 and 0.3 mg of various brands have been examined, using laser-induced breakdown spectroscopy (LIBS) technique. The statistical methods such as the principal component analysis (PCA) and the partial least square regression analysis (PLSR) have been employed on LIBS spectral data for classifying and developing the calibration models of drug samples. We have developed the ratio-based calibration model applying PLSR in which relative spectral intensity ratios H/C, H/N and O/N are used. Further, the developed model has been employed to predict the relative concentration of element in unknown drug samples. The experiment has been performed in air and argon atmosphere, respectively, and the obtained results have been compared. The present model provides rapid spectroscopic method for drug analysis with high statistical significance for online control and measurement process in a wide variety of pharmaceutical industrial applications.

  11. An introduction to planar chromatography and its application to natural products isolation.

    PubMed

    Gibbons, Simon

    2012-01-01

    Thin-layer chromatography (TLC) is an easy, inexpensive, rapid, and the most widely used method for the analysis and isolation of small organic natural and synthetic products. It also has use in the biological evaluation of organic compounds, particularly in the areas of antimicrobial and antioxidant metabolites and for the evaluation of acetylcholinesterase inhibitors which have utility in the treatment of Alzheimer's disease. The ease and inexpensiveness of use of this technique, coupled with the ability to rapidly develop separation and bioassay protocols will ensure that TLC will be used for some considerable time alongside conventional instrumental methods. This chapter deals with the basic principles of TLC and describes methods for the analysis and isolation of natural products. Examples of methods for isolation of several classes of natural product are detailed and protocols for TLC bioassays are given.

  12. Rapid Quantitative Analysis of Multiple Explosive Compound Classes on a Single Instrument via Flow-Injection Analysis Tandem Mass Spectrometry.

    PubMed

    Ostrinskaya, Alla; Kunz, Roderick R; Clark, Michelle; Kingsborough, Richard P; Ong, Ta-Hsuan; Deneault, Sandra

    2018-05-24

    A flow-injection analysis tandem mass spectrometry (FIA MSMS) method was developed for rapid quantitative analysis of 10 different inorganic and organic explosives. Performance is optimized by tailoring the ionization method (APCI/ESI), de-clustering potentials, and collision energies for each specific analyte. In doing so, a single instrument can be used to detect urea nitrate, potassium chlorate, 2,4,6-trinitrotoluene, 2,4,6-trinitrophenylmethylnitramine, triacetone triperoxide, hexamethylene triperoxide diamine, pentaerythritol tetranitrate, 1,3,5-trinitroperhydro-1,3,5-triazine, nitroglycerin, and octohy-dro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine with sensitivities all in the picogram per milliliter range. In conclusion, FIA APCI/ESI MSMS is a fast (<1 min/sample), sensitive (~pg/mL LOQ), and precise (intraday RSD < 10%) method for trace explosive detection that can play an important role in criminal and attributional forensics, counterterrorism, and environmental protection areas, and has the potential to augment or replace several of the existing explosive detection methods. © 2018 American Academy of Forensic Sciences.

  13. Rapid Antibiotic Susceptibility Testing of Uropathogenic E. coli by Tracking Submicron Scale Motion of Single Bacterial Cells.

    PubMed

    Syal, Karan; Shen, Simon; Yang, Yunze; Wang, Shaopeng; Haydel, Shelley E; Tao, Nongjian

    2017-08-25

    To combat antibiotic resistance, a rapid antibiotic susceptibility testing (AST) technology that can identify resistant infections at disease onset is required. Current clinical AST technologies take 1-3 days, which is often too slow for accurate treatment. Here we demonstrate a rapid AST method by tracking sub-μm scale bacterial motion with an optical imaging and tracking technique. We apply the method to clinically relevant bacterial pathogens, Escherichia coli O157: H7 and uropathogenic E. coli (UPEC) loosely tethered to a glass surface. By analyzing dose-dependent sub-μm motion changes in a population of bacterial cells, we obtain the minimum bactericidal concentration within 2 h using human urine samples spiked with UPEC. We validate the AST method using the standard culture-based AST methods. In addition to population studies, the method allows single cell analysis, which can identify subpopulations of resistance strains within a sample.

  14. Rapid determination of 210Po in water samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2013-08-02

    A new rapid method for the determination of 210Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210Po in water samples have typically involved spontaneous auto-deposition of 210Po onto silver or other metal disks followed by counting by alphamore » spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210Pb analysis. A new rapid method for 210Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210Po.« less

  15. Development of a multiplex PCR-based rapid typing method for enterohemorrhagic Escherichia coli O157 strains.

    PubMed

    Ooka, Tadasuke; Terajima, Jun; Kusumoto, Masahiro; Iguchi, Atsushi; Kurokawa, Ken; Ogura, Yoshitoshi; Asadulghani, Md; Nakayama, Keisuke; Murase, Kazunori; Ohnishi, Makoto; Iyoda, Sunao; Watanabe, Haruo; Hayashi, Tetsuya

    2009-09-01

    Enterohemorrhagic Escherichia coli O157 (EHEC O157) is a food-borne pathogen that has raised worldwide public health concern. The development of simple and rapid strain-typing methods is crucial for the rapid detection and surveillance of EHEC O157 outbreaks. In the present study, we developed a multiplex PCR-based strain-typing method for EHEC O157, which is based on the variability in genomic location of IS629 among EHEC O157 strains. This method is very simple, in that the procedures are completed within 2 h, the analysis can be performed without the need for special equipment or techniques (requiring only conventional PCR and agarose gel electrophoresis systems), the results can easily be transformed into digital data, and the genes for the major virulence markers of EHEC O157 (the stx(1), stx(2), and eae genes) can be detected simultaneously. Using this method, 201 EHEC O157 strains showing different XbaI digestion patterns in pulsed-field gel electrophoresis (PFGE) analysis were classified into 127 types, and outbreak-related strains showed identical or highly similar banding patterns. Although this method is less discriminatory than PFGE, it may be useful as a primary screening tool for EHEC O157 outbreaks.

  16. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    USGS Publications Warehouse

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  17. Quantification of Kryptofix 2.2.2 in [18F]fluorine-labelled radiopharmaceuticals by rapid-resolution liquid chromatography.

    PubMed

    Lao, Yexing; Yang, Cuiping; Zou, Wei; Gan, Manquan; Chen, Ping; Su, Weiwei

    2012-05-01

    The cryptand Kryptofix 2.2.2 is used extensively as a phase-transfer reagent in the preparation of [18F]fluoride-labelled radiopharmaceuticals. However, it has considerable acute toxicity. The aim of this study was to develop and validate a method for rapid (within 1 min), specific and sensitive quantification of Kryptofix 2.2.2 at trace levels. Chromatographic separations were carried out by rapid-resolution liquid chromatography (Agilent ZORBAX SB-C18 rapid-resolution column, 2.1 × 30 mm, 3.5 μm). Tandem mass spectra were acquired using a triple quadrupole mass spectrometer equipped with an electrospray ionization interface. Quantitative mass spectrometric analysis was conducted in positive ion mode and multiple reaction monitoring mode for the m/z 377.3 → 114.1 transition for Kryptofix 2.2.2. The external standard method was used for quantification. The method met the precision and efficiency requirements for PET radiopharmaceuticals, providing satisfactory results for specificity, matrix effect, stability, linearity (0.5-100 ng/ml, r(2)=0.9975), precision (coefficient of variation < 5%), accuracy (relative error < ± 3%), sensitivity (lower limit of quantification=0.5 ng) and detection time (<1 min). Fluorodeoxyglucose (n=6) was analysed, and the Kryptofix 2.2.2 content was found to be well below the maximum permissible levels approved by the US Food and Drug Administration. The developed method has a short analysis time (<1 min) and high sensitivity (lower limit of quantification=0.5 ng/ml) and can be successfully applied to rapid quantification of Kryptofix 2.2.2 at trace levels in fluorodeoxyglucose. This method could also be applied to other [18F]fluorine-labelled radiopharmaceuticals that use Kryptofix 2.2.2 as a phase-transfer reagent.

  18. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared tomore » NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.« less

  19. Rapid Characterization of Microorganisms by Mass Spectrometry—What Can Be Learned and How?

    NASA Astrophysics Data System (ADS)

    Fenselau, Catherine C.

    2013-08-01

    Strategies for the rapid and reliable analysis of microorganisms have been sought to meet national needs in defense, homeland security, space exploration, food and water safety, and clinical diagnosis. Mass spectrometry has long been a candidate technique because it is extremely rapid and can provide highly specific information. It has excellent sensitivity. Molecular and fragment ion masses provide detailed fingerprints, which can also be interpreted. Mass spectrometry is also a broad band method—everything has a mass—and it is automatable. Mass spectrometry is a physiochemical method that is orthogonal and complementary to biochemical and morphological methods used to characterize microorganisms.

  20. Transversely Excited Atmospheric CO2 Laser-Induced Plasma Spectroscopy for the Detection of Heavy Metals in Soil

    NASA Astrophysics Data System (ADS)

    Khumaeni, A.; Sugito, H.; Setia Budi, W.; Yoyo Wardaya, A.

    2018-01-01

    A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO2 laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO2 laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.

  1. Rapid determination of 1-deoxynojirimycin in Morus alba L. leaves by direct analysis in real time (DART) mass spectrometry.

    PubMed

    Xu, Bin; Zhang, Dong-Yang; Liu, Ze-Yu; Zhang, Ying; Liu, Li; Li, Long; Liu, Charles C; Wu, Guo-Hua

    2015-10-10

    A new method based on a Direct Analysis in Real Time (DART) ionization source coupled with triple quadrupole tandem mass spectrometry has been developed for rapid qualitative and quantitative analyses of 1-deoxynojirimycin (DNJ) in mulberry leaves. Two ions produced from DNJ, [M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162), are observed using DART-MS in the positive ion mode. The peak areas of the two selected ions monitoring (SIM) signals of ([M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162)) are integrated to determine the peak area for quantitative analyses. A reasonable linear regression equation is obtained in the range of 1.01 to 40.50 μg/mL, with a linear coefficient (R(2)) of 0.996. The limits of detection (LOD) and quantification (LOQ) of the method are 0.25 and 0.80 μg/mL, respectively. The range of recovery is shown to be 87.73-95.61%. The results derived from the developed DART-MS method are in good agreement with those from the conventional HPLC-FLD method. By contrast, DART-MS in SIM mode is a simple, rapid and high-throughput approach for the determination of the DNJ content in mulberry leaves. The present method is advantageous for the rapid screening of mulberry leaves containing high DNJ contents. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Rapid identification of apolipoprotein E genotypes by high-resolution melting analysis in Chinese Han and African Fang populations.

    PubMed

    Zhan, Xiu-Hui; Zha, Guang-Cai; Jiao, Ji-Wei; Yang, Li-Ye; Zhan, Xiao-Fen; Chen, Jiang-Tao; Xie, Dong-DE; Eyi, Urbano Monsuy; Matesa, Rocio Apicante; Obono, Maximo Miko Ondo; Ehapo, Carlos Sala; Wei, Er-Jia; Zheng, Yu-Zhong; Yang, Hui; Lin, Min

    2015-02-01

    Apolipoprotein E (APOE) gene polymorphism can affect APOE gene transcription, serum lipid levels and repair of tissue damage, which could place individuals at serious risk of cardiovascular disease or certain infectious diseases. Recently, high-resolution melting (HRM) analysis was reported to be a simple, inexpensive, accurate and sensitive method for the genotyping or/and scanning of rare mutations. For this reason, an HRM analysis was used in the present study for APOE genotyping in the Southern Chinese Han and African Fang populations. A total of 100 healthy Southern Chinese Han and 175 healthy African Fang individuals attended the study. Polymerase chain reaction-DNA sequencing was used as a reference method for the genotyping of these samples. The six APOE genotypes could all be rapidly and efficiently identified by HRM analysis, and 100% concordance was found between the HRM analysis and the reference method. The allele frequencies of APOE in the Southern Chinese Han population were 7.0, 87.5 and 5.5% for ɛ2, ɛ3 and ɛ4, respectively. In the African Fang population, the allele frequencies of APOE were 24.3, 65.7 and 10.0% for ɛ2, ɛ3 and ɛ4, respectively. A statistically significant difference was found between the allele frequencies between the populations (P<0.05). In conclusion, the present study revealed the molecular characterization of APOE gene polymorphism in the Han population from the Chaozhou region of Southern China and the Fang population from Equatorial Guinea. The findings of the study indicated that HRM analysis could be used as an accurate and sensitive method for the rapid screening and identification of APOE genotypes in prospective clinical and population genetic analyses.

  3. Toward a high-throughput method for determining vicine and convicine levels in faba bean seeds using flow injection analysis combined with tandem mass spectrometry.

    PubMed

    Purves, Randy W; Khazaei, Hamid; Vandenberg, Albert

    2018-08-01

    Although faba bean provides environmental and health benefits, vicine and convicine (v-c) limit its use as a source of vegetable protein. Crop improvement efforts to minimize v-c concentration require low-cost, rapid screening methods to distinguish between high and low v-c genotypes to accelerate development of new cultivars and to detect out-crossing events. To assist crop breeders, we developed a unique and rapid screening method that uses a 60 s instrumental analysis step to accurately distinguish between high and low v-c genotypes. The method involves flow injection analysis (FIA) coupled with tandem mass spectrometry (i.e., selective reaction monitoring, SRM). Using seeds with known v-c levels as calibrants, measured v-c levels were comparable with liquid chromatography (LC)-SRM results and the method was used to screen 370 faba bean genotypes. Widespread use of FIA-SRM will accelerate breeding of low v-c faba bean, thereby alleviating concerns about anti-nutritional effects of v-c in this crop. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Estimating phylogenetic trees from genome-scale data.

    PubMed

    Liu, Liang; Xi, Zhenxiang; Wu, Shaoyuan; Davis, Charles C; Edwards, Scott V

    2015-12-01

    The heterogeneity of signals in the genomes of diverse organisms poses challenges for traditional phylogenetic analysis. Phylogenetic methods known as "species tree" methods have been proposed to directly address one important source of gene tree heterogeneity, namely the incomplete lineage sorting that occurs when evolving lineages radiate rapidly, resulting in a diversity of gene trees from a single underlying species tree. Here we review theory and empirical examples that help clarify conflicts between species tree and concatenation methods, and misconceptions in the literature about the performance of species tree methods. Considering concatenation as a special case of the multispecies coalescent model helps explain differences in the behavior of the two methods on phylogenomic data sets. Recent work suggests that species tree methods are more robust than concatenation approaches to some of the classic challenges of phylogenetic analysis, including rapidly evolving sites in DNA sequences and long-branch attraction. We show that approaches, such as binning, designed to augment the signal in species tree analyses can distort the distribution of gene trees and are inconsistent. Computationally efficient species tree methods incorporating biological realism are a key to phylogenetic analysis of whole-genome data. © 2015 New York Academy of Sciences.

  5. Rapid analysis of charge variants of monoclonal antibodies using non-linear salt gradient in cation-exchange high performance liquid chromatography.

    PubMed

    Joshi, Varsha; Kumar, Vijesh; Rathore, Anurag S

    2015-08-07

    A method is proposed for rapid development of a short, analytical cation exchange high performance liquid chromatography method for analysis of charge heterogeneity in monoclonal antibody products. The parameters investigated and optimized include pH, shape of elution gradient and length of the column. It is found that the most important parameter for development of a shorter method is the choice of the shape of elution gradient. In this paper, we propose a step by step approach to develop a non-linear sigmoidal shape gradient for analysis of charge heterogeneity for two different monoclonal antibody products. The use of this gradient not only decreases the run time of the method to 4min against the conventional method that takes more than 40min but also the resolution is retained. Superiority of the phosphate gradient over sodium chloride gradient for elution of mAbs is also observed. The method has been successfully evaluated for specificity, sensitivity, linearity, limit of detection, and limit of quantification. Application of this method as a potential at-line process analytical technology tool has been suggested. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. A Laboratory Experiment for Rapid Determination of the Stability of Vitamin C

    ERIC Educational Resources Information Center

    Adem, Seid M.; Lueng, Sam H.; Elles, Lisa M. Sharpe; Shaver, Lee Alan

    2016-01-01

    Experiments in laboratory manuals intended for general, organic, and biological (GOB) chemistry laboratories include few opportunities for students to engage in instrumental methods of analysis. Many of these students seek careers in modern health-related fields where experience in spectroscopic techniques would be beneficial. A simple, rapid,…

  7. Development and validation of a rapid method for microcystins in fish and comparing LC-MS/MS results with ELISA

    USDA-ARS?s Scientific Manuscript database

    Microcystins (MCs) are the most common cyanotoxins found world-wide in freshwater, brackish and marine environments. The rapid and accurate analysis of microcystins and nodularin in fish tissue is important for determining occurrence, monitoring trends, and exposure monitoring for risk assessment a...

  8. Rapid screening and quantification of residual pesticides and illegal adulterants in red wine by direct analysis in real time mass spectrometry.

    PubMed

    Guo, Tianyang; Fang, Pingping; Jiang, Juanjuan; Zhang, Feng; Yong, Wei; Liu, Jiahui; Dong, Yiyang

    2016-11-04

    A rapid method to screen and quantify multi-class analytic targets in red wine has been developed by direct analysis in real time (DART) coupled with triple quadruple tandem mass spectrometry (QqQ-MS). A modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) procedure was used for increasing analytical speed and reducing matrix effect, and the multiple reaction monitoring (MRM) in DART-MS/MS ensured accurate analysis. One bottle of wine containing 50 pesticides and 12 adulterants, i.e., preservatives, antioxidant, sweeteners, and azo dyes, could be totally determined less than 12min. This method exhibited proper linearity (R 2 ≥0.99) in the range of 1-1000ng/mL for pesticides and 10-5000ng/mL for adulterants. The limits of detection (LODs) were obtained in a 0.5-50ng/mL range for pesticides and 5-50ng/mL range for adulterants, and the limits of quantification (LOQs) were in a 1-100ng/mL range for pesticides and 10-250ng/mL range for adulterants. Three spiked levels for each analyte in wine were evaluated, and the recoveries were in a scope of 75-120%. The results demonstrated DART-MS/MS was a rapid and simple method, and could be applied to rapid analyze residual pesticides and illegal adulterants in a large quantities of red wine. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Optical Coherence Tomography in the UK Biobank Study – Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies

    PubMed Central

    Grossi, Carlota M.; Foster, Paul J.; Yang, Qi; Reisman, Charles A.; Chan, Kinpui; Peto, Tunde; Thomas, Dhanes; Patel, Praveen J.

    2016-01-01

    Purpose To describe an approach to the use of optical coherence tomography (OCT) imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness. Methods In UK Biobank, OCT images were acquired between 2009 and 2010 using a commercially available “spectral domain” OCT device (3D OCT-1000, Topcon). Images were obtained using a raster scan protocol, 6 mm x 6 mm in area, and consisting of 128 B-scans. OCT image sets were stored on UK Biobank servers in a central repository, adjacent to high performance computers. Rapid, automated analysis of retinal thickness was performed using custom image segmentation software developed by the Topcon Advanced Biomedical Imaging Laboratory (TABIL). This software employs dual-scale gradient information to allow for automated segmentation of nine intraretinal boundaries in a rapid fashion. Results 67,321 participants (134,642 eyes) in UK Biobank underwent OCT imaging of both eyes as part of the ocular module. 134,611 images were successfully processed with 31 images failing segmentation analysis due to corrupted OCT files or withdrawal of subject consent for UKBB study participation. Average time taken to call up an image from the database and complete segmentation analysis was approximately 120 seconds per data set per login, and analysis of the entire dataset was completed in approximately 28 days. Conclusions We report an approach to the rapid, automated measurement of retinal thickness from nearly 140,000 OCT image sets from the UK Biobank. In the near future, these measurements will be publically available for utilization by researchers around the world, and thus for correlation with the wealth of other data collected in UK Biobank. The automated analysis approaches we describe may be of utility for future large population-based epidemiological studies, clinical trials, and screening programs that employ OCT imaging. PMID:27716837

  10. Potential of cross-priming amplification and DNA-based lateral-flow strip biosensor for rapid on-site GMO screening.

    PubMed

    Huang, Xin; Zhai, Congcong; You, Qimin; Chen, Hongjun

    2014-07-01

    The requirement to monitor the presence of genetically modified organisms (GMO) in a variety of marked products has generated an increasing demand for reliable, rapid, and time and cost-effective analytical methods. Here we report an on-site method for rapid detection of cauliflower mosaic virus promoter (CaMV 35S), a common element present in most GMO, using cross-priming amplification (CPA) technology. Detection was achieved using a DNA-based contamination-proof strip biosensor. The limit of detection was 30 copies for the pBI121 plasmid containing the CaMV 35S gene. The certified reference sample of GM maize line MON810 was detectable even at the low relative mass concentration of 0.05%. The developed CPA method had high specificity for the CaMV 35S gene, as compared with other GM lines not containing this gene and non-GM products. The method was further validated using nine real-world samples, and the results were confirmed by real-time PCR analysis. Because of its simplicity, rapidity, and high sensitivity, this method of detecting the CaMV 35S gene has great commercial prospects for rapid GMO screening of high-consumption food and agriculture products.

  11. Differentiation of the two major species of Echinacea (E. augustifolia and E. purpurea) using a flow injection mass spectrometric (FIMS) fingerprinting method and chemometric analysis

    USDA-ARS?s Scientific Manuscript database

    A rapid, simple, and reliable flow-injection mass spectrometric (FIMS) method was developed to discriminate two major Echinacea species (E. purpurea and E. angustifolia) samples. Fifty-eight Echinacea samples collected from United States were analyzed using FIMS. Principle component analysis (PCA) a...

  12. Analytical Fuselage and Wing Weight Estimation of Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Chambers, Mark C.; Ardema, Mark D.; Patron, Anthony P.; Hahn, Andrew S.; Miura, Hirokazu; Moore, Mark D.

    1996-01-01

    A method of estimating the load-bearing fuselage weight and wing weight of transport aircraft based on fundamental structural principles has been developed. This method of weight estimation represents a compromise between the rapid assessment of component weight using empirical methods based on actual weights of existing aircraft, and detailed, but time-consuming, analysis using the finite element method. The method was applied to eight existing subsonic transports for validation and correlation. Integration of the resulting computer program, PDCYL, has been made into the weights-calculating module of the AirCraft SYNThesis (ACSYNT) computer program. ACSYNT has traditionally used only empirical weight estimation methods; PDCYL adds to ACSYNT a rapid, accurate means of assessing the fuselage and wing weights of unconventional aircraft. PDCYL also allows flexibility in the choice of structural concept, as well as a direct means of determining the impact of advanced materials on structural weight. Using statistical analysis techniques, relations between the load-bearing fuselage and wing weights calculated by PDCYL and corresponding actual weights were determined.

  13. Rapid Radiochemical Methods for Asphalt Paving Material ...

    EPA Pesticide Factsheets

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  14. Rapid detection and differentiation of Clonorchis sinensis and Opisthorchis viverrini using real-time PCR and high resolution melting analysis.

    PubMed

    Cai, Xian-Quan; Yu, Hai-Qiong; Li, Rong; Yue, Qiao-Yun; Liu, Guo-Hua; Bai, Jian-Shan; Deng, Yan; Qiu, De-Yi; Zhu, Xing-Quan

    2014-01-01

    Clonorchis sinensis and Opisthorchis viverrini are both important fish-borne pathogens, causing serious public health problem in Asia. The present study developed an assay integrating real-time PCR and high resolution melting (HRM) analysis for the specific detection and rapid identification of C. sinensis and O. viverrini. Primers targeting COX1 gene were highly specific for these liver flukes, as evidenced by the negative amplification of closely related trematodes. Assays using genomic DNA extracted from the two flukes yielded specific amplification and their identity was confirmed by sequencing, having the accuracy of 100% in reference to conventional methods. The assay was proved to be highly sensitive with a detection limit below 1 pg of purified genomic DNA, 5 EPG, or 1 metacercaria of C. sinensis. Moreover, C. sinensis and O. viverrini were able to be differentiated by their HRM profiles. The method can reduce labor of microscopic examination and the contamination of agarose electrophoresis. Moreover, it can differentiate these two flukes which are difficult to be distinguished using other methods. The established method provides an alternative tool for rapid, simple, and duplex detection of C. sinensis and O. viverrini.

  15. Rapid microfluidic analysis of a Y-STR multiplex for screening of forensic samples.

    PubMed

    Gibson-Daw, Georgiana; Albani, Patricia; Gassmann, Marcus; McCord, Bruce

    2017-02-01

    In this paper, we demonstrate a rapid analysis procedure for use with a small set of rapidly mutating Y chromosomal short tandem repeat (Y-STR) loci that combines both rapid polymerase chain reaction (PCR) and microfluidic separation elements. The procedure involves a high-speed polymerase and a rapid cycling protocol to permit PCR amplification in 16 min. The resultant amplified sample is next analysed using a short 1.8-cm microfluidic electrophoresis system that permits a four-locus Y-STR genotype to be produced in 80 s. The entire procedure takes less than 25 min from sample collection to result. This paper describes the rapid amplification protocol as well as studies of the reproducibility and sensitivity of the procedure and its optimisation. The amplification process utilises a small high-speed thermocycler, microfluidic device and compact laptop, making it portable and potentially useful for rapid, inexpensive on-site genotyping. The four loci used for the multiplex were selected due to their rapid mutation rates and should proved useful in preliminary screening of samples and suspects. Overall, this technique provides a method for rapid sample screening of suspect and crime scene samples in forensic casework. Graphical abstract ᅟ.

  16. Method for rapid estimation of scour at highway bridges based on limited site data

    USGS Publications Warehouse

    Holnbeck, S.R.; Parrett, Charles

    1997-01-01

    Limited site data were used to develop a method for rapid estimation of scour at highway bridges. The estimates can be obtained in a matter of hours rather than several days as required by more-detailed methods. Such a method is important because scour assessments are needed to identify scour-critical bridges throughout the United States. Using detailed scour-analysis methods and scour-prediction equations recommended by the Federal Highway Administration, the U.S. Geological Survey, in cooperation with the Montana Department of Transportation, obtained contraction, pier, and abutment scour-depth data for sites from 10 States.The data were used to develop relations between scour depth and hydraulic variables that can be rapidly measured in the field. Relations between scour depth and hydraulic variables, in the form of envelope curves, were based on simpler forms of detailed scour-prediction equations. To apply the rapid-estimation method, a 100-year recurrence interval peak discharge is determined, and bridge- length data are used in the field with graphs relating unit discharge to velocity and velocity to bridge backwater as a basis for estimating flow depths and other hydraulic variables that can then be applied using the envelope curves. The method was tested in the field. Results showed good agreement among individuals involved and with results from more-detailed methods. Although useful for identifying potentially scour-critical bridges, themethod does not replace more-detailed methods used for design purposes. Use of the rapid- estimation method should be limited to individuals having experience in bridge scour, hydraulics, and flood hydrology, and some training in use of the method.

  17. Rapid determination of isoamyl nitrite in pharmaceutical preparations by flow injection analysis with on-line UV irradiation and luminol chemiluminescence detection.

    PubMed

    Kishikawa, Naoya; Kondo, Naoko; Amponsaa-Karikari, Abena; Kodamatani, Hitoshi; Ohyama, Kaname; Nakashima, Kenichiro; Yamazaki, Shigeo; Kuroda, Naotaka

    2014-02-01

    Isoamyl nitrite is used as a therapeutic reagent for cardiac angina and as an antidote for cyanide poisoning, but it is abused because of its euphoric properties. Therefore, a method to determine isoamyl nitrite is required in many fields, including pharmaceutical and forensic studies. In this study, a simple, rapid and sensitive method for the determination of isoamyl nitrite was developed using a flow injection analysis system equipped with a chemiluminescence detector and on-line photoreactor. This method is based on on-line ultraviolet irradiation of isoamyl nitrite and subsequent luminol chemiluminescence detection without the addition of an oxidant. A linear standard curve was obtained up to 1.0 μM of isoamyl nitrite with a detection limit (blank + 3SD) of 0.03 μM. The method was successfully applied to determine isoamyl nitrite content in pharmaceutical preparations. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Rapid Method for the Radioisotopic Analysis of Gaseous End Products of Anaerobic Metabolism

    PubMed Central

    Nelson, David R.; Zeikus, J. G.

    1974-01-01

    A gas chromatographic procedure for the simultaneous analysis of 14C-labeled and unlabeled metabolic gases from microbial methanogenic systems is described. H2, CH4, and CO2 were separated within 2.5 min on a Carbosieve B column and were detected by thermal conductivity. Detector effluents were channeled into a gas proportional counter for measurement of radioactivity. This method was more rapid, sensitive, and convenient than gas chromatography-liquid scintillation techniques. The gas chromatography-gas proportional counting procedure was used to characterize the microbial decomposition of organic matter in anaerobic lake sediments and to monitor 14CH4 formation from H2 and 14CO2 by Methanosarcina barkeri. PMID:4854029

  19. Rapid analysis of malachite green and leucomalachite green in fish muscles with surface-enhanced resonance Raman scattering.

    PubMed

    Zhang, Yuanyuan; Yu, Wansong; Pei, Lu; Lai, Keqiang; Rasco, Barbara A; Huang, Yiqun

    2015-02-15

    Surface-enhanced resonance Raman scattering (SERRS) coupled with gold nanospheres was applied for rapid analysis of the hazardous substances malachite green (MG) and leucomalachite green (LMG) in fish muscle tissues. The lowest concentration of MG that could be detected was 0.5ngmL(-1) with high linear correlation (R(2)=0.970-0.998) between MG concentration and intensities of characteristic Raman peaks. A simplified sample preparation method taking less than 1h for recovering MG and LMG in fish fillets was developed for SERRS analysis, and 4-8 samples could be handled in parallel. MG and LMG could be detected in extracts of tilapia fish fillets at as low as 2ngg(-1) with SERRS and a simple principle component analysis method. For six other fish species, the lowest detectable concentration of MG ranged from 1ngg(-1) to 10ngg(-1). This study provides a new sensitive approach for the detection of trace amounts of the prohibited drugs MG and LMG in muscle food, which has the potential for rapidly screening a large number of samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Development of Advanced Methods of Structural and Trajectory Analysis for Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Ardema, Mark D.

    1996-01-01

    In this report the author describes: (1) development of advanced methods of structural weight estimation, and (2) development of advanced methods of flight path optimization. A method of estimating the load-bearing fuselage weight and wing weight of transport aircraft based on fundamental structural principles has been developed. This method of weight estimation represents a compromise between the rapid assessment of component weight using empirical methods based on actual weights of existing aircraft and detailed, but time-consuming, analysis using the finite element method. The method was applied to eight existing subsonic transports for validation and correlation. Integration of the resulting computer program, PDCYL, has been made into the weights-calculating module of the AirCraft SYNThesis (ACSYNT) computer program. ACSYNT bas traditionally used only empirical weight estimation methods; PDCYL adds to ACSYNT a rapid, accurate means of assessing the fuselage and wing weights of unconventional aircraft. PDCYL also allows flexibility in the choice of structural concept, as well as a direct means of determining the impact of advanced materials on structural weight.

  1. High temperature flow-through device for rapid solubilization and analysis

    DOEpatents

    West, Jason A. A. [Castro Valley, CA; Hukari, Kyle W [San Ramon, CA; Patel, Kamlesh D [Dublin, CA; Peterson, Kenneth A [Albuquerque, NM; Renzi, Ronald F [Tracy, CA

    2009-09-22

    Devices and methods for thermally lysing of biological material, for example vegetative bacterial cells and bacterial spores, are provided. Hot solution methods for solubilizing bacterial spores are described. Systems for direct analysis are disclosed including thermal lysers coupled to sample preparation stations. Integrated systems capable of performing sample lysis, labeling and protein fingerprint analysis of biological material, for example, vegetative bacterial cells, bacterial spores and viruses are provided.

  2. High temperature flow-through device for rapid solubilization and analysis

    DOEpatents

    West, Jason A. A.; Hukari, Kyle W.; Patel, Kamlesh D.; Peterson, Kenneth A.; Renzi, Ronald F.

    2013-04-23

    Devices and methods for thermally lysing of biological material, for example vegetative bacterial cells and bacterial spores, are provided. Hot solution methods for solubilizing bacterial spores are described. Systems for direct analysis are disclosed including thermal lysers coupled to sample preparation stations. Integrated systems capable of performing sample lysis, labeling and protein fingerprint analysis of biological material, for example, vegetative bacterial cells, bacterial spores and viruses are provided.

  3. Dimensional Precision Research of Wax Molding Rapid Prototyping based on Droplet Injection

    NASA Astrophysics Data System (ADS)

    Mingji, Huang; Geng, Wu; yan, Shan

    2017-11-01

    The traditional casting process is complex, the mold is essential products, mold quality directly affect the quality of the product. With the method of rapid prototyping 3D printing to produce mold prototype. The utility wax model has the advantages of high speed, low cost and complex structure. Using the orthogonal experiment as the main method, analysis each factors of size precision. The purpose is to obtain the optimal process parameters, to improve the dimensional accuracy of production based on droplet injection molding.

  4. Selective cultivation and rapid detection of Staphylococcus aureus by computer vision.

    PubMed

    Wang, Yong; Yin, Yongguang; Zhang, Chaonan

    2014-03-01

    In this paper, we developed a selective growth medium and a more rapid detection method based on computer vision for selective isolation and identification of Staphylococcus aureus from foods. The selective medium consisted of tryptic soy broth basal medium, 3 inhibitors (NaCl, K2 TeO3 , and phenethyl alcohol), and 2 accelerators (sodium pyruvate and glycine). After 4 h of selective cultivation, bacterial detection was accomplished using computer vision. The total analysis time was 5 h. Compared to the Baird-Parker plate count method, which requires 4 to 5 d, this new detection method offers great time savings. Moreover, our novel method had a correlation coefficient of greater than 0.998 when compared with the Baird-Parker plate count method. The detection range for S. aureus was 10 to 10(7) CFU/mL. Our new, rapid detection method for microorganisms in foods has great potential for routine food safety control and microbiological detection applications. © 2014 Institute of Food Technologists®

  5. Histogram analysis for smartphone-based rapid hematocrit determination

    PubMed Central

    Jalal, Uddin M.; Kim, Sang C.; Shim, Joon S.

    2017-01-01

    A novel and rapid analysis technique using histogram has been proposed for the colorimetric quantification of blood hematocrits. A smartphone-based “Histogram” app for the detection of hematocrits has been developed integrating the smartphone embedded camera with a microfluidic chip via a custom-made optical platform. The developed histogram analysis shows its effectiveness in the automatic detection of sample channel including auto-calibration and can analyze the single-channel as well as multi-channel images. Furthermore, the analyzing method is advantageous to the quantification of blood-hematocrit both in the equal and varying optical conditions. The rapid determination of blood hematocrits carries enormous information regarding physiological disorders, and the use of such reproducible, cost-effective, and standard techniques may effectively help with the diagnosis and prevention of a number of human diseases. PMID:28717569

  6. Rapid analysis of the main components of the total glycosides of Ranunculus japonicus by UPLC/Q-TOF-MS.

    PubMed

    Rui, Wen; Chen, Hongyuan; Tan, Yuzhi; Zhong, Yanmei; Feng, Yifan

    2010-05-01

    A rapid method for the analysis of the main components of the total glycosides of Ranunculus japonicus (TGOR) was developed using ultra-performance liquid chromatography with quadrupole-time-of-flight mass spectrometry (UPLC/Q-TOF-MS). The separation analysis was performed on a Waters Acquity UPLC system and the accurate mass of molecules and their fragment ions were determined by Q-TOF MS. Twenty compounds, including lactone glycosides, flavonoid glycosides and flavonoid aglycones, were identified and tentatively deduced on the basis of their elemental compositions, MS/MS data and relevant literature. The results demonstrated that lactone glycosides and flavonoids were the main constituents of TGOR. Furthermore, an effective and rapid pattern was established allowing for the comprehensive and systematic characterization of the complex samples.

  7. Rapid determination of tannins in tanning baths by adaptation of BSA method.

    PubMed

    Molinari, R; Buonomenna, M G; Cassano, A; Drioli, E

    2001-01-01

    A rapid and reproducible method for the determination of tannins in vegetable tanning baths is proposed as a modification of the BSA method for grain tannins existing in literature. The protein BSA was used instead of leather powder employed in the Filter Method, which is adopted in Italy and various others countries of Central Europe. In this rapid method the tannin contents is determined by means a spectrophotometric reading and not by means a gravimetric analysis of the Filter Method. The BSA method, which belongs to mixed methods (which use both precipitation and complexation of tannins), consists of selective precipitation of tannin from a solution containing also non tannins by BSA, the dissolution of precipitate and the quantification of free tannin amount by its complexation with Fe(III) in hydrochloric solutions. The absorbance values, read at 522 nm, have been expressed in terms of tannic acid concentration by using a calibration curve made with standard solutions of tannic acid; these have been correlated with the results obtained by using the Filter Method.

  8. Detection of Salmonella enterica in Meat in Less than 5 Hours by a Low-Cost and Noncomplex Sample Preparation Method

    PubMed Central

    Hoorfar, J.; Hansen, F.; Christensen, J.; Mansdal, S.; Josefsen, M. H.

    2016-01-01

    ABSTRACT Salmonella is recognized as one of the most important foodborne bacteria and has wide health and socioeconomic impacts worldwide. Fresh pork meat is one of the main sources of Salmonella, and efficient and fast methods for detection are therefore necessary. Current methods for Salmonella detection in fresh meat usually include >16 h of culture enrichment, in a few cases <12 h, thus requiring at least two working shifts. Here, we report a rapid (<5 h) and high-throughput method for screening of Salmonella in samples from fresh pork meat, consisting of a 3-h enrichment in standard buffered peptone water and a real-time PCR-compatible sample preparation method based on filtration, centrifugation, and enzymatic digestion, followed by fast-cycling real-time PCR detection. The method was validated in an unpaired comparative study against the Nordic Committee on Food Analysis (NMKL) reference culture method 187. Pork meat samples (n = 140) were either artificially contaminated with Salmonella at 0, 1 to 10, or 10 to 100 CFU/25 g of meat or naturally contaminated. Cohen's kappa for the degree of agreement between the rapid method and the reference was 0.64, and the relative accuracy, sensitivity, and specificity for the rapid method were 81.4, 95.1, and 97.9%, respectively. The 50% limit of detections (LOD50s) were 8.8 CFU/25 g for the rapid method and 7.7 CFU/25 g for the reference method. Implementation of this method will enable faster release of Salmonella low-risk meat, providing savings for meat producers, and it will help contribute to improved food safety. IMPORTANCE While the cost of analysis and hands-on time of the presented rapid method were comparable to those of reference culture methods, the fast product release by this method can provide the meat industry with a competitive advantage. Not only will the abattoirs save costs for work hours and cold storage, but consumers and retailers will also benefit from fresher meat with a longer shelf life. Furthermore, the presented sample preparation might be adjusted for application in the detection of other pathogenic bacteria in different sample types. PMID:27986726

  9. Detection of Salmonella enterica in Meat in Less than 5 Hours by a Low-Cost and Noncomplex Sample Preparation Method.

    PubMed

    Fachmann, M S R; Löfström, C; Hoorfar, J; Hansen, F; Christensen, J; Mansdal, S; Josefsen, M H

    2017-03-01

    Salmonella is recognized as one of the most important foodborne bacteria and has wide health and socioeconomic impacts worldwide. Fresh pork meat is one of the main sources of Salmonella , and efficient and fast methods for detection are therefore necessary. Current methods for Salmonella detection in fresh meat usually include >16 h of culture enrichment, in a few cases <12 h, thus requiring at least two working shifts. Here, we report a rapid (<5 h) and high-throughput method for screening of Salmonella in samples from fresh pork meat, consisting of a 3-h enrichment in standard buffered peptone water and a real-time PCR-compatible sample preparation method based on filtration, centrifugation, and enzymatic digestion, followed by fast-cycling real-time PCR detection. The method was validated in an unpaired comparative study against the Nordic Committee on Food Analysis (NMKL) reference culture method 187. Pork meat samples ( n = 140) were either artificially contaminated with Salmonella at 0, 1 to 10, or 10 to 100 CFU/25 g of meat or naturally contaminated. Cohen's kappa for the degree of agreement between the rapid method and the reference was 0.64, and the relative accuracy, sensitivity, and specificity for the rapid method were 81.4, 95.1, and 97.9%, respectively. The 50% limit of detections (LOD 50 s) were 8.8 CFU/25 g for the rapid method and 7.7 CFU/25 g for the reference method. Implementation of this method will enable faster release of Salmonella low-risk meat, providing savings for meat producers, and it will help contribute to improved food safety. IMPORTANCE While the cost of analysis and hands-on time of the presented rapid method were comparable to those of reference culture methods, the fast product release by this method can provide the meat industry with a competitive advantage. Not only will the abattoirs save costs for work hours and cold storage, but consumers and retailers will also benefit from fresher meat with a longer shelf life. Furthermore, the presented sample preparation might be adjusted for application in the detection of other pathogenic bacteria in different sample types. Copyright © 2017 American Society for Microbiology.

  10. Detection of Biomarkers of Pathogenic Naegleria fowleri Through Mass Spectrometry and Proteomics

    PubMed Central

    Moura, Hercules; Izquierdo, Fernando; Woolfitt, Adrian R.; Wagner, Glauber; Pinto, Tatiana; del Aguila, Carmen; Barr, John R.

    2017-01-01

    Emerging methods based on mass spectrometry (MS) can be used in the rapid identification of microorganisms. Thus far, these practical and rapidly evolving methods have mainly been applied to characterize prokaryotes. We applied matrix-assisted laser-desorption-ionization-time-of-flight mass spectrometry MALDI-TOF MS in the analysis of whole cells of 18 N. fowleri isolates belonging to three genotypes. Fourteen originated from the cerebrospinal fluid or brain tissue of primary amoebic meningoencephalitis patients and four originated from water samples of hot springs, rivers, lakes or municipal water supplies. Whole Naegleria trophozoites grown in axenic cultures were washed and mixed with MALDI matrix. Mass spectra were acquired with a 4700 TOF-TOF instrument. MALDI-TOF MS yielded consistent patterns for all isolates examined. Using a combination of novel data processing methods for visual peak comparison, statistical analysis and proteomics database searching we were able to detect several biomarkers that can differentiate all species and isolates studied, along with common biomarkers for all N. fowleri isolates. Naegleria fowleri could be easily separated from other species within the genus Naegleria. A number of peaks detected were tentatively identified. MALDI-TOF MS fingerprinting is a rapid, reproducible, high-throughput alternative method for identifying Naegleria isolates. This method has potential for studying eukaryotic agents. PMID:25231600

  11. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    PubMed

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Rapid Microcystin Determination Using a Paper Spray Ionization Method with a Time-of-Flight Mass Spectrometry System.

    PubMed

    Zhu, Xiaoqiang; Huang, Zhengxu; Gao, Wei; Li, Xue; Li, Lei; Zhu, Hui; Mo, Ting; Huang, Bao; Zhou, Zhen

    2016-07-13

    The eutrophication of surface water sources and climate changes have resulted in an annual explosion of cyanobacterial blooms in many irrigating and drinking water resources. To decrease health risks to the public, a rapid real time method for the synchronous determination of two usually harmful microcystins (MC-RR and MC-LR) in environmental water samples was built by employing a paper spray ionization method coupled with a time-of-flight mass spectrometer system. With this approach, direct analysis of microcystin mixtures without sample preparation has been achieved. Rapid detection was performed, simulating the release process of microcystins in reservoir water samples, and the routine detection frequency was every three minutes. The identification time of microcystins was reduced from several hours to a few minutes. The limit of detection is 1 μg/L, and the limit of quantitation is 3 μg/L. This method displays the ability for carrying out rapid, direct, and high-throughput experiments for determination of microcystins, and it would be of significant interest for environmental and food safety applications.

  13. RAPID ON-SITE METHODS OF CHEMICAL ANALYSIS

    EPA Science Inventory

    The analysis of potentially hazardous air, water and soil samples collected and shipped to service laboratories off-site is time consuming and expensive. This Chapter addresses the practical alternative of performing the requisite analytical services on-site. The most significant...

  14. Improved sample preparation and rapid UHPLC analysis of SO2 binding carbonyls in wine by derivatisation to 2,4-dinitrophenylhydrazine.

    PubMed

    Jackowetz, J N; Mira de Orduña, R

    2013-08-15

    Sulphur dioxide (SO2) is essential for the preservation of wines. The presence of SO2 binding compounds in musts and wines may limit sulphite efficacy leading to higher total SO2 additions, which may exceed SO2 limits permitted by law and pose health risks for sensitive individuals. An improved method for the quantification of significant wine SO2 binding compounds is presented that applies a novel sample treatment approach and rapid UHPLC separation. Glucose, galacturonic acid, alpha-ketoglutarate, pyruvate, acetoin and acetaldehyde were derivatised with 2,4-dinitrophenylhydrazine and separated using a solid core C18 phase by ultra high performance liquid chromatography. Addition of EDTA to samples prevented de novo acetaldehyde formation from ethanol oxidation. Optimised derivatisation duration enhanced reproducibility and allowed for glucose and galacturonic acid quantification. High glucose residues were found to interfere with the recovery of other SO2 binders, but practical SO2 concentrations and red wine pigments did not affect derivatisation efficiency. The calibration range, method accuracy, precision and limits of detection were found to be satisfactory for routine analysis of SO2 binders in wines. The current method represents a significant improvement in the comprehensive analysis of SO2 binding wine carbonyls. It allows for the quantification of major SO2 binders at practical analyte concentrations, and uses a simple sample treatment method that prevents treatment artifacts. Equipment utilisation could be reduced by rapid LC separation while maintaining analytical performance parameters. The improved method will be a valuable addition for the analysis of total SO2 binder pools in oenological samples. Published by Elsevier Ltd.

  15. A rapid analysis of plasma/serum ethylene and propylene glycol by headspace gas chromatography.

    PubMed

    Ehlers, Alexandra; Morris, Cory; Krasowski, Matthew D

    2013-12-01

    A rapid headspace-gas chromatography (HS-GC) method was developed for the analysis of ethylene glycol and propylene glycol in plasma and serum specimens using 1,3-propanediol as the internal standard. The method employed a single-step derivitization using phenylboronic acid, was linear to 200 mg/dL and had a lower limit of quantitation of 1 mg/dL suitable for clinical analyses. The analytical method described allows for laboratories with HS-GC instrumentation to analyze ethanol, methanol, isopropanol, ethylene glycol, and propylene glycol on a single instrument with rapid switch-over from alcohols to glycols analysis. In addition to the novel HS-GC method, a retrospective analysis of patient specimens containing ethylene glycol and propylene glycol was also described. A total of 36 patients ingested ethylene glycol, including 3 patients who presented with two separate admissions for ethylene glycol toxicity. Laboratory studies on presentation to hospital for these patients showed both osmolal and anion gap in 13 patients, osmolal but not anion gap in 13 patients, anion but not osmolal gap in 8 patients, and 1 patient with neither an osmolal nor anion gap. Acidosis on arterial blood gas was present in 13 cases. Only one fatality was seen; this was a patient with initial serum ethylene glycol concentration of 1282 mg/dL who died on third day of hospitalization. Propylene glycol was common in patients being managed for toxic ingestions, and was often attributed to iatrogenic administration of propylene glycol-containing medications such as activated charcoal and intravenous lorazepam. In six patients, propylene glycol contributed to an abnormally high osmolal gap. The common presence of propylene glycol in hospitalized patients emphasizes the importance of being able to identify both ethylene glycol and propylene glycol by chromatographic methods.

  16. A rapid, one step preparation for measuring selected free plus SO2-bound wine carbonyls by HPLC-DAD/MS.

    PubMed

    Han, Guomin; Wang, Hua; Webb, Michael R; Waterhouse, Andrew L

    2015-03-01

    Carbonyl compounds are produced during fermentation and chemical oxidation during wine making and aging, and they are important to wine flavor and color stability. Since wine also contains these compounds as α-hydroxysulfonates as a result of their reaction with sulfur dioxide, an alkaline pre-treatment requiring oxygen exclusion has been used to release these bound carbonyls for analysis. By modifying the method to hydrolyze the hydroxysulfonates with heating and acid in the presence of 2,4-dinitrophenylhydrazine (DNPH), the carbonyl compounds are simultaneously and quickly released and derivatized, resulting in a simpler and more rapid method. In addition, the method avoids air exclusion complications during hydrolysis by the addition of sulfur dioxide. The method was optimized for temperature, reaction time, and the concentrations of DNPH, sulfur dioxide and acid. The hydrazones were shown to be stable for 10 h, adequate time for chromatographic analysis by HPLC-DAD/MS. This method is demonstrated for 2-ketoglutaric acid, pyruvic acid, acetoin and acetaldehyde, wine carbonyls of very different reactivities, and it offers good specificity, high recovery and low limits of detection. This new rapid, simple method is demonstrated for the measurement of carbonyl compounds in a range of wines of different ages and grape varieties. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. [Preparation of Gold Nano-Particles as Surface-Enhanced Raman Scattering Sensors for Analysis of Banned Food Dye Chrysoidin in Yuba].

    PubMed

    Xu, Xue-qin; Liu, Qiong-hua; Yang, Fang; Qian, Jiang; Chen, Jian; Lin, Zhen-yu; Qiu, Bin

    2015-11-01

    Chrysoidin is a kind of banned food dye, and it has been illegally used for coloring food. A rapid detection and quantification method is developed and applied in analysis chrysoidin in yuba. Gold nanoparticles are synthesized by using hexadecyl trimethyl ammonium bromide (CTAB) as the bifunctional ligand to link the solid substrate and the AuNPs. The laser wavelength used for quantitative is 1594 cm⁻¹. Significant differences between different concentrations of chrysoidin are verified by multiple variable analysis. A relationship between the logarithm of the concentrations and the intensity of laser is proved using univariate analysis method. The calibration curves showed good linearity in the range of 0.001-0.5 mmol · L⁻¹ with correlation coefficients r = 0.995. The method is successfully applied to the determination of chrysoidin in yuba. The average recoveries of the drugs spiked at 50 and 500 µg · g⁻¹ levels are 82.4% and 116.9%, and the relative standard deviations (RSD) are 3.8% and 4.0%. The method is simple, rapid, sensitive and accurate in the determination of chrysoidin.

  18. Determination of copper by isotopic dilution.

    PubMed

    Faquim, E S; Munita, C S

    1994-01-01

    A rapid and selective method was used for the determination of copper by isotopic dilution employing substoichiometric extraction with dithizone in carbon tetrachloride. The appropriate pH range for the substoichiometric extraction was 2-7. In the analysis, even a large excess of elements forming extractable complexes with dithizone does not interfere. The accuracy and precision of the method were evaluated. The method has been applied to analysis of reference materials, wheat flour, wine, and beer.

  19. Alternative microbial methods: An overview and selection criteria.

    PubMed

    Jasson, Vicky; Jacxsens, Liesbeth; Luning, Pieternel; Rajkovic, Andreja; Uyttendaele, Mieke

    2010-09-01

    This study provides an overview and criteria for the selection of a method, other than the reference method, for microbial analysis of foods. In a first part an overview of the general characteristics of rapid methods available, both for enumeration and detection, is given with reference to relevant bibliography. Perspectives on future development and the potential of the rapid method for routine application in food diagnostics are discussed. As various alternative "rapid" methods in different formats are available on the market, it can be very difficult for a food business operator or for a control authority to select the most appropriate method which fits its purpose. Validation of a method by a third party, according to international accepted protocol based upon ISO 16140, may increase the confidence in the performance of a method. A list of at the moment validated methods for enumeration of both utility indicators (aerobic plate count) and hygiene indicators (Enterobacteriaceae, Escherichia coli, coagulase positive Staphylococcus) as well as for detection of the four major pathogens (Salmonella spp., Listeria monocytogenes, E. coli O157 and Campylobacter spp.) is included with reference to relevant websites to check for updates. In a second part of this study, selection criteria are introduced to underpin the choice of the appropriate method(s) for a defined application. The selection criteria link the definition of the context in which the user of the method functions - and thus the prospective use of the microbial test results - with the technical information on the method and its operational requirements and sustainability. The selection criteria can help the end user of the method to obtain a systematic insight into all relevant factors to be taken into account for selection of a method for microbial analysis. Copyright 2010 Elsevier Ltd. All rights reserved.

  20. NEW TARGET AND CONTROL ASSAYS FOR QUANTITATIVE POLYMERASE CHAIN REACTION (QPCR) ANALYSIS OF ENTEROCOCCI IN WATER

    EPA Science Inventory

    Enterococci are frequently monitored in water samples as indicators of fecal pollution. Attention is now shifting from culture based methods for enumerating these organisms to more rapid molecular methods such as QPCR. Accurate quantitative analyses by this method requires highly...

  1. TOWARDS A STANDARD METHOD FOR THE MEASUREMENT OF ORGANIC CARBON IN SEDIMENTS

    EPA Science Inventory

    The precisions achieved by two different methods for analysis of organic carbon in soils and sediments were determined and compared. The first method is a rapid dichromate oxidation technique (Walkley-Black) that has long been a standard in soil chemistry. The second is an automa...

  2. Sequential injection analysis with chemiluminescence detection for rapid monitoring of commercial Calendula officinalis extractions.

    PubMed

    Hughes, Rachel R; Scown, David; Lenehan, Claire E

    2015-01-01

    Plant extracts containing high levels of antioxidants are desirable due to their reported health benefits. Most techniques capable of determining the antioxidant activity of plant extracts are unsuitable for rapid at-line analysis as they require extensive sample preparation and/or long analysis times. Therefore, analytical techniques capable of real-time or pseudo real-time at-line monitoring of plant extractions, and determination of extraction endpoints, would be useful to manufacturers of antioxidant-rich plant extracts. To develop a reliable method for the rapid at-line extraction monitoring of antioxidants in plant extracts. Calendula officinalis extracts were prepared from dried flowers and analysed for antioxidant activity using sequential injection analysis (SIA) with chemiluminescence (CL) detection. The intensity of CL emission from the reaction of acidic potassium permanganate with antioxidants within the extract was used as the analytical signal. The SIA-CL method was applied to monitor the extraction of C. officinalis over the course of a batch extraction to determine the extraction endpoint. Results were compared with those from ultra high performance liquid chromatography (UHPLC). Pseudo real-time, at-line monitoring showed the level of antioxidants in a batch extract of Calendula officinalis plateaued after 100 min of extraction. These results correlated well with those of an offline UHPLC study. SIA-CL was found to be a suitable method for pseudo real-time monitoring of plant extractions and determination of extraction endpoints with respect to antioxidant concentrations. The method was applied at-line in the manufacturing industry. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Coupling carbon nanotube film microextraction with desorption corona beam ionization for rapid analysis of Sudan dyes (I-IV) and Rhodamine B in chilli oil.

    PubMed

    Chen, Di; Huang, Yun-Qing; He, Xiao-Mei; Shi, Zhi-Guo; Feng, Yu-Qi

    2015-03-07

    A rapid analysis method by coupling carbon nanotube film (CNTF) microextraction with desorption corona beam ionization (DCBI) was developed for the determination of Sudan dyes (I-IV) and Rhodamine B in chilli oil samples. Typically, CNTF was immersed into the diluted solution of chilli oil for extraction, which was then placed directly under the visible plasma beam tip of the DCBI source for desorption and ionization. Under optimized conditions, five dyes were simultaneously determined using this method. Results showed that the analytes were enriched by the CNTF through the π-π interactions, and the proposed method could significantly improve the sensitivities of these compounds, compared to the direct analysis by DCBI-MS/MS. The method with a linear range of 0.08-12.8 μg g(-1) and good linear relationships (R(2) > 0.93) in a multiple reaction monitoring (MRM) mode was developed. Satisfactory reproducibility was achieved. Relative standard deviations (RSDs) were less than 20.0%. The recoveries ranged from 80.0 to 110.0%, and the limits of detection (LODs) were in the range of 1.4-21 ng g(-1). Finally, the feasibility of the method was further exhibited by the determination of five illegal dyes in chilli powder. These results demonstrate that the proposed method consumes less time and solvent than conventional HPLC-based methods and avoids the contamination of chromatographic column and ion source from non-volatile oil. With the help of a 72-well shaker, multiple samples could be treated simultaneously, which ensures high throughput for the entire pretreatment process. In conclusion, it provides a rapid and high-throughput approach for the determination of such illicit additions in chilli products.

  4. Simple and rapid analytical method for detection of amino acids in blood using blood spot on filter paper, fast-GC/MS and isotope dilution technique.

    PubMed

    Kawana, Shuichi; Nakagawa, Katsuhiro; Hasegawa, Yuki; Yamaguchi, Seiji

    2010-11-15

    A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H₈-Val, ²H₃-Leu, ²H₃-Met and ²H₅-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 μmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 μmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 μmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Analysis of 3D printing parameters of gears for hybrid manufacturing

    NASA Astrophysics Data System (ADS)

    Budzik, Grzegorz; Przeszlowski, Łukasz; Wieczorowski, Michal; Rzucidlo, Arkadiusz; Gapinski, Bartosz; Krolczyk, Grzegorz

    2018-05-01

    The paper deals with analysis and selection of parameters of rapid prototyping of gears by selective sintering of metal powders. Presented results show wide spectrum of application of RP systems in manufacturing processes of machine elements, basing on analysis of market in term of application of additive manufacturing technology in different sectors of industry. Considerable growth of these methods over the past years can be observed. The characteristic errors of printed model with respect to ideal one for each technique were pointed out. Special attention was paid to the method of preparation of numerical data CAD/STL/RP. Moreover the analysis of manufacturing processes of gear type elements was presented. The tested gears were modeled with different allowances for final machining and made by DMLS. Metallographic analysis and strength tests on prepared specimens were performed. The above mentioned analysis and tests were used to compare the real properties of material with the nominal ones. To improve the quality of surface after sintering the gears were subjected to final machining. The analysis of geometry of gears after hybrid manufacturing method was performed (fig.1). The manufacturing process was defined in a traditional way as well as with the aid of modern manufacturing techniques. Methodology and obtained results can be used for other machine elements than gears and constitutes the general theory of production processes in rapid prototyping methods as well as in designing and implementation of production.

  6. Mass spectrometry imaging for visualizing organic analytes in food.

    PubMed

    Handberg, Eric; Chingin, Konstantin; Wang, Nannan; Dai, Ximo; Chen, Huanwen

    2015-01-01

    The demand for rapid chemical imaging of food products steadily increases. Mass spectrometry (MS) is featured by excellent molecular specificity of analysis and is, therefore, a very attractive method for chemical profiling. MS for food imaging has increased significantly over the past decade, aided by the emergence of various ambient ionization techniques that allow direct and rapid analysis in ambient environment. In this article, the current status of food imaging with MSI is reviewed. The described approaches include matrix-assisted laser desorption/ionization (MALDI), but emphasize desorption atmospheric pressure photoionization (DAPPI), electrospray-assisted laser desorption/ionization (ELDI), probe electrospray ionization (PESI), surface desorption atmospheric pressure chemical ionization (SDAPCI), and laser ablation flowing atmospheric pressure afterglow (LA-FAPA). The methods are compared with regard to spatial resolution; analysis speed and time; limit of detection; and technical aspects. The performance of each method is illustrated with the description of a related application. Specific requirements in food imaging are discussed. © 2014 Wiley Periodicals, Inc.

  7. Selective One-Dimensional Total Correlation Spectroscopy Nuclear Magnetic Resonance Experiments for a Rapid Identification of Minor Components in the Lipid Fraction of Milk and Dairy Products: Toward Spin Chromatography?

    PubMed

    Papaemmanouil, Christina; Tsiafoulis, Constantinos G; Alivertis, Dimitrios; Tzamaloukas, Ouranios; Miltiadou, Despoina; Tzakos, Andreas G; Gerothanassis, Ioannis P

    2015-06-10

    We report a rapid, direct, and unequivocal spin-chromatographic separation and identification of minor components in the lipid fraction of milk and common dairy products with the use of selective one-dimensional (1D) total correlation spectroscopy (TOCSY) nuclear magnetic resonance (NMR) experiments. The method allows for the complete backbone spin-coupling network to be elucidated even in strongly overlapped regions and in the presence of major components from 4 × 10(2) to 3 × 10(3) stronger NMR signal intensities. The proposed spin-chromatography method does not require any derivatization steps for the lipid fraction, is selective with excellent resolution, is sensitive with quantitation capability, and compares favorably to two-dimensional (2D) TOCSY and gas chromatography-mass spectrometry (GC-MS) methods of analysis. The results of the present study demonstrated that the 1D TOCSY NMR spin-chromatography method can become a procedure of primary interest in food analysis and generally in complex mixture analysis.

  8. Direct analysis of six antibiotics in wastewater samples using rapid high-performance liquid chromatography coupled with diode array detector: a chemometric study towards green analytical chemistry.

    PubMed

    Vosough, Maryam; Rashvand, Masoumeh; Esfahani, Hadi M; Kargosha, Kazem; Salemi, Amir

    2015-04-01

    In this work, a rapid HPLC-DAD method has been developed for the analysis of six antibiotics (amoxicillin, metronidazole, sulfamethoxazole, ofloxacine, sulfadiazine and sulfamerazine) in the sewage treatment plant influent and effluent samples. Decreasing the chromatographic run time to less than 4 min as well as lowering the cost per analysis, were achieved through direct injection of the samples into the HPLC system followed by chemometric analysis. The problem of the complete separation of the analytes from each other and/or from the matrix ingredients was resolved as a posteriori. The performance of MCR/ALS and U-PLS/RBL, as second-order algorithms, was studied and comparable results were obtained from implication of these modeling methods. It was demonstrated that the proposed methods could be used promisingly as green analytical strategies for detection and quantification of the targeted pollutants in wastewater samples while avoiding the more complicated high cost instrumentations. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Analysis of volatile compounds by open-air ionization mass spectrometry.

    PubMed

    Meher, Anil Kumar; Chen, Yu-Chie

    2017-05-08

    This study demonstrates a simple method for rapid and in situ identification of volatile and endogenous compounds in culinary spice samples through mass spectrometry (MS). This method only requires a holder for solid spice sample (2-3 mm) that is placed close to a mass spectrometer inlet, which is applied with a high voltage. Volatile species responsible for the aroma of the spice samples can be readily detected by the mass spectrometer. Sample pretreatment is not required prior to MS analysis, and no solvent was used during MS analysis. The high voltage applied to the inlet of the mass spectrometer induces the ionization of volatile compounds released from the solid spice samples. Furthermore, moisture in the air also contributes to the ionization of volatile compounds. Dried spices including cinnamon and cloves are used as the model sample to demonstrate this straightforward MS analysis, which can be completed within few seconds. Furthermore, we also demonstrate the suitability of the current method for rapid screening of cinnamon quality through detection of the presence of a hepatotoxic agent, i.e. coumarin. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Alternatives to current flow cytometry data analysis for clinical and research studies.

    PubMed

    Gondhalekar, Carmen; Rajwa, Bartek; Patsekin, Valery; Ragheb, Kathy; Sturgis, Jennifer; Robinson, J Paul

    2018-02-01

    Flow cytometry has well-established methods for data analysis based on traditional data collection techniques. These techniques typically involved manual insertion of tube samples into an instrument that, historically, could only measure 1-3 colors. The field has since evolved to incorporate new technologies for faster and highly automated sample preparation and data collection. For example, the use of microwell plates on benchtop instruments is now a standard on virtually every new instrument, and so users can easily accumulate multiple data sets quickly. Further, because the user must carefully define the layout of the plate, this information is already defined when considering the analytical process, expanding the opportunities for automated analysis. Advances in multi-parametric data collection, as demonstrated by the development of hyperspectral flow-cytometry, 20-40 color polychromatic flow cytometry, and mass cytometry (CyTOF), are game-changing. As data and assay complexity increase, so too does the complexity of data analysis. Complex data analysis is already a challenge to traditional flow cytometry software. New methods for reviewing large and complex data sets can provide rapid insight into processes difficult to define without more advanced analytical tools. In settings such as clinical labs where rapid and accurate data analysis is a priority, rapid, efficient and intuitive software is needed. This paper outlines opportunities for analysis of complex data sets using examples of multiplexed bead-based assays, drug screens and cell cycle analysis - any of which could become integrated into the clinical environment. Copyright © 2017. Published by Elsevier Inc.

  11. Verification and Validation in a Rapid Software Development Process

    NASA Technical Reports Server (NTRS)

    Callahan, John R.; Easterbrook, Steve M.

    1997-01-01

    The high cost of software production is driving development organizations to adopt more automated design and analysis methods such as rapid prototyping, computer-aided software engineering (CASE) tools, and high-level code generators. Even developers of safety-critical software system have adopted many of these new methods while striving to achieve high levels Of quality and reliability. While these new methods may enhance productivity and quality in many cases, we examine some of the risks involved in the use of new methods in safety-critical contexts. We examine a case study involving the use of a CASE tool that automatically generates code from high-level system designs. We show that while high-level testing on the system structure is highly desirable, significant risks exist in the automatically generated code and in re-validating releases of the generated code after subsequent design changes. We identify these risks and suggest process improvements that retain the advantages of rapid, automated development methods within the quality and reliability contexts of safety-critical projects.

  12. Rapid curing of solution-processed zinc oxide films by pulse-light annealing for thin-film transistor applications

    NASA Astrophysics Data System (ADS)

    Kim, Dong Wook; Park, Jaehoon; Hwang, Jaeeun; Kim, Hong Doo; Ryu, Jin Hwa; Lee, Kang Bok; Baek, Kyu Ha; Do, Lee-Mi; Choi, Jong Sun

    2015-01-01

    In this study, a pulse-light annealing method is proposed for the rapid fabrication of solution-processed zinc oxide (ZnO) thinfilm transistors (TFTs). Transistors that were fabricated by the pulse-light annealing method, with the annealing being carried out at 90℃ for 15 s, exhibited a mobility of 0.05 cm2/Vs and an on/off current ratio of 106. Such electrical properties are quite close to those of devices that are thermally annealed at 165℃ for 40 min. X-ray photoelectron spectroscopy analysis of ZnO films showed that the activation energy required to form a Zn-O bond is entirely supplied within 15 s of pulse-light exposure. We conclude that the pulse-light annealing method is viable for rapidly curing solution-processable oxide semiconductors for TFT applications.

  13. Rapid, portable and cost-effective yeast cell viability and concentration analysis using lensfree on-chip microscopy and machine learning.

    PubMed

    Feizi, Alborz; Zhang, Yibo; Greenbaum, Alon; Guziak, Alex; Luong, Michelle; Chan, Raymond Yan Lok; Berg, Brandon; Ozkan, Haydar; Luo, Wei; Wu, Michael; Wu, Yichen; Ozcan, Aydogan

    2016-11-01

    Monitoring yeast cell viability and concentration is important in brewing, baking and biofuel production. However, existing methods of measuring viability and concentration are relatively bulky, tedious and expensive. Here we demonstrate a compact and cost-effective automatic yeast analysis platform (AYAP), which can rapidly measure cell concentration and viability. AYAP is based on digital in-line holography and on-chip microscopy and rapidly images a large field-of-view of 22.5 mm 2 . This lens-free microscope weighs 70 g and utilizes a partially-coherent illumination source and an opto-electronic image sensor chip. A touch-screen user interface based on a tablet-PC is developed to reconstruct the holographic shadows captured by the image sensor chip and use a support vector machine (SVM) model to automatically classify live and dead cells in a yeast sample stained with methylene blue. In order to quantify its accuracy, we varied the viability and concentration of the cells and compared AYAP's performance with a fluorescence exclusion staining based gold-standard using regression analysis. The results agree very well with this gold-standard method and no significant difference was observed between the two methods within a concentration range of 1.4 × 10 5 to 1.4 × 10 6 cells per mL, providing a dynamic range suitable for various applications. This lensfree computational imaging technology that is coupled with machine learning algorithms would be useful for cost-effective and rapid quantification of cell viability and density even in field and resource-poor settings.

  14. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants.

    PubMed

    Salazar, Carolina; Armenta, Jenny M; Shulaev, Vladimir

    2012-07-06

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10-11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary.

  15. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants

    PubMed Central

    Salazar, Carolina; Armenta, Jenny M.; Shulaev, Vladimir

    2012-01-01

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10−11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary. PMID:24957640

  16. Analysis of polonium-210 in food products and bioassay samples by isotope-dilution alpha spectrometry.

    PubMed

    Lin, Zhichao; Wu, Zhongyu

    2009-05-01

    A rapid and reliable radiochemical method coupled with a simple and compact plating apparatus was developed, validated, and applied for the analysis of (210)Po in variety of food products and bioassay samples. The method performance characteristics, including accuracy, precision, robustness, and specificity, were evaluated along with a detailed measurement uncertainty analysis. With high Po recovery, improved energy resolution, and effective removal of interfering elements by chromatographic extraction, the overall method accuracy was determined to be better than 5% with measurement precision of 10%, at 95% confidence level.

  17. Electrochemical Biosensors for Rapid Detection of Foodborne Salmonella: A Critical Overview

    PubMed Central

    Cinti, Stefano; Volpe, Giulia; Piermarini, Silvia; Delibato, Elisabetta; Palleschi, Giuseppe

    2017-01-01

    Salmonella has represented the most common and primary cause of food poisoning in many countries for at least over 100 years. Its detection is still primarily based on traditional microbiological culture methods which are labor-intensive, extremely time consuming, and not suitable for testing a large number of samples. Accordingly, great efforts to develop rapid, sensitive and specific methods, easy to use, and suitable for multi-sample analysis, have been made and continue. Biosensor-based technology has all the potentialities to meet these requirements. In this paper, we review the features of the electrochemical immunosensors, genosensors, aptasensors and phagosensors developed in the last five years for Salmonella detection, focusing on the critical aspects of their application in food analysis. PMID:28820458

  18. Rapid methods for the isolation of actinides Sr, Tc and Po from raw urine.

    PubMed

    McAlister, Daniel R; Horwitz, E Philip; Harvey, James T

    2011-08-01

    Rapid methods for the isolation and analysis of individual actinides (Th, U, Pu, Am/Cm) and Sr, Tc and Po from small volumes of raw urine have been developed. The methods involve acidification of the sample and the addition of aluminum nitrate or aluminum chloride salting-out agent prior to isolation of the desired analyte using a tandem combination of prefilter material and extraction chromatographic resin. The method has been applied to the separation of individual analytes from spiked urine samples. Analytes were recovered in high yield and radionuclide purity with separation times as low as 30 min. The chemistry employed is compatible with automation on the ARSIIe instrument.

  19. Flow Injection Analysis with Electrochemical Detection for Rapid Identification of Platinum-Based Cytostatics and Platinum Chlorides in Water

    PubMed Central

    Kominkova, Marketa; Heger, Zbynek; Zitka, Ondrej; Kynicky, Jindrich; Pohanka, Miroslav; Beklova, Miroslava; Adam, Vojtech; Kizek, Rene

    2014-01-01

    Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts of platinum ions in the water environment. The impacts of these pollutants on the water ecosystem are not sufficiently investigated as well as their content in water sources. In order to facilitate the detection of various types of platinum, we have developed a new, rapid, screening flow injection analysis method with electrochemical detection (FIA-ED). Our method, based on monitoring of the changes in electrochemical behavior of analytes, maintained by various pH buffers (Britton-Robinson and phosphate buffer) and potential changes (1,000, 1,100 and 1,200 mV) offers rapid and cheap selective determination of platinum-based cytostatics and platinum chlorides, which can also be present as contaminants in water environments. PMID:24499878

  20. "Batch" kinetics in flow: online IR analysis and continuous control.

    PubMed

    Moore, Jason S; Jensen, Klavs F

    2014-01-07

    Currently, kinetic data is either collected under steady-state conditions in flow or by generating time-series data in batch. Batch experiments are generally considered to be more suitable for the generation of kinetic data because of the ability to collect data from many time points in a single experiment. Now, a method that rapidly generates time-series reaction data from flow reactors by continuously manipulating the flow rate and reaction temperature has been developed. This approach makes use of inline IR analysis and an automated microreactor system, which allowed for rapid and tight control of the operating conditions. The conversion/residence time profiles at several temperatures were used to fit parameters to a kinetic model. This method requires significantly less time and a smaller amount of starting material compared to one-at-a-time flow experiments, and thus allows for the rapid generation of kinetic data. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Improving the sensitivity and accuracy of gamma activation analysis for the rapid determination of gold in mineral ores.

    PubMed

    Tickner, James; Ganly, Brianna; Lovric, Bojan; O'Dwyer, Joel

    2017-04-01

    Mining companies rely on chemical analysis methods to determine concentrations of gold in mineral ore samples. As gold is often mined commercially at concentrations around 1 part-per-million, it is necessary for any analysis method to provide good sensitivity as well as high absolute accuracy. We describe work to improve both the sensitivity and accuracy of the gamma activation analysis (GAA) method for gold. We present analysis results for several suites of ore samples and discuss the design of a GAA facility designed to replace conventional chemical assay in industrial applications. Copyright © 2017. Published by Elsevier Ltd.

  2. Cellufine sulfate column chromatography as a simple, rapid, and effective method to purify dengue virus.

    PubMed

    Kanlaya, Rattiyaporn; Thongboonkerd, Visith

    2016-08-01

    Conventional method to purify/concentrate dengue virus (DENV) is time-consuming with low virus recovery yield. Herein, we applied cellufine sulfate column chromatography to purify/concentrate DENV based on the mimicry between heparan sulfate and DENV envelope protein. Comparative analysis demonstrated that this new method offered higher purity (as determined by less contamination of bovine serum albumin) and recovery yield (as determined by greater infectivity). Moreover, overall duration used for cellufine sulfate column chromatography to purify/concentrate DENV was approximately 1/20 of that of conventional method. Therefore, cellufine sulfate column chromatography serves as a simple, rapid, and effective alternative method for DENV purification/concentration. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Rapid Determination of Clenbuterol in Pork by Direct Immersion Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry.

    PubMed

    Ye, Diru; Wu, Susu; Xu, Jianqiao; Jiang, Ruifen; Zhu, Fang; Ouyang, Gangfeng

    2016-02-01

    Direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid analysis of clenbuterol in pork for the first time. In this work, a low-cost homemade 44 µm polydimethylsiloxane (PDMS) SPME fiber was employed to extract clenbuterol in pork. After extraction, derivatization was performed by suspending the fiber in the headspace of the 2 mL sample vial saturated with a vapor of 100 µL hexamethyldisilazane. Lastly, the fiber was directly introduced to GC-MS for analysis. All parameters that influenced absorption (extraction time), derivatization (derivatization reagent, time and temperature) and desorption (desorption time) were optimized. Under optimized conditions, the method offered a wide linear range (10-1000 ng g(-1)) and a low detection limit (3.6 ng g(-1)). Finally, the method was successfully applied in the analysis of pork from the market, and recoveries of the method for spiked pork were 97.4-105.7%. Compared with the traditional solvent extraction method, the proposed method was much cheaper and fast. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Rapid detection and classification of Salmonella enterica shedding in feedlot cattle utilizing Roka Bioscience Atlas Salmonella detection assay for the analysis of rectoanal mucosal swabs

    USDA-ARS?s Scientific Manuscript database

    With an increasing focus on preharvest food safety, rapid methods are required for the detection and quantification of foodborne pathogens such as Salmonella enterica in beef cattle. We validated the Atlas Salmonella Detection Assay (SEN), a nucleic acid amplification technology that targets Salmone...

  5. Ultra-performance liquid chromatography tandem mass-spectrometry (uplc-ms/ms) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

    USDA-ARS?s Scientific Manuscript database

    A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...

  6. Rapid Characterization of Microalgae and Microalgae Mixtures Using Matrix-Assisted Laser Desorption Ionization Time-Of-Flight Mass Spectrometry (MALDI-TOF MS)

    PubMed Central

    Barbano, Duane; Diaz, Regina; Zhang, Lin; Sandrin, Todd; Gerken, Henri; Dempster, Thomas

    2015-01-01

    Current molecular methods to characterize microalgae are time-intensive and expensive. Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) may represent a rapid and economical alternative approach. The objectives of this study were to determine whether MALDI-TOF MS can be used to: 1) differentiate microalgae at the species and strain levels and 2) characterize simple microalgal mixtures. A common protein extraction sample preparation method was used to facilitate rapid mass spectrometry-based analysis of 31 microalgae. Each yielded spectra containing between 6 and 56 peaks in the m/z 2,000 to 20,000 range. The taxonomic resolution of this approach appeared higher than that of 18S rDNA sequence analysis. For example, two strains of Scenedesmus acutus differed only by two 18S rDNA nucleotides, but yielded distinct MALDI-TOF mass spectra. Mixtures of two and three microalgae yielded relatively complex spectra that contained peaks associated with members of each mixture. Interestingly, though, mixture-specific peaks were observed at m/z 11,048 and 11,230. Our results suggest that MALDI-TOF MS affords rapid characterization of individual microalgae and simple microalgal mixtures. PMID:26271045

  7. Rapid and simple immunochemical screening combined with hand-shaking extraction for thiamethoxam residue in agricultural products.

    PubMed

    Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro

    2013-06-01

    With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.

  8. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    ERIC Educational Resources Information Center

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  9. Rapid LC-MS/MS quantification of the major benzodiazepines and their metabolites on dried blood spots using a simple and cost-effective sample pretreatment.

    PubMed

    Déglon, Julien; Versace, François; Lauer, Estelle; Widmer, Christèle; Mangin, Patrice; Thomas, Aurélien; Staub, Christian

    2012-06-01

    Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.

  10. Development and single-laboratory validation of a UHPLC-MS/MS method for quantitation of microcystins and nodularin in natural water, cyanobacteria, shellfish and algal supplement tablet powders.

    PubMed

    Turner, Andrew D; Waack, Julia; Lewis, Adam; Edwards, Christine; Lawton, Linda

    2018-02-01

    A simple, rapid UHPLC-MS/MS method has been developed and optimised for the quantitation of microcystins and nodularin in wide variety of sample matrices. Microcystin analogues targeted were MC-LR, MC-RR, MC-LA, MC-LY, MC-LF, LC-LW, MC-YR, MC-WR, [Asp3] MC-LR, [Dha7] MC-LR, MC-HilR and MC-HtyR. Optimisation studies were conducted to develop a simple, quick and efficient extraction protocol without the need for complex pre-analysis concentration procedures, together with a rapid sub 5min chromatographic separation of toxins in shellfish and algal supplement tablet powders, as well as water and cyanobacterial bloom samples. Validation studies were undertaken on each matrix-analyte combination to the full method performance characteristics following international guidelines. The method was found to be specific and linear over the full calibration range. Method sensitivity in terms of limits of detection, quantitation and reporting were found to be significantly improved in comparison to LC-UV methods and applicable to the analysis of each of the four matrices. Overall, acceptable recoveries were determined for each of the matrices studied, with associated precision and within-laboratory reproducibility well within expected guidance limits. Results from the formalised ruggedness analysis of all available cyanotoxins, showed that the method was robust for all parameters investigated. The results presented here show that the optimised LC-MS/MS method for cyanotoxins is fit for the purpose of detection and quantitation of a range of microcystins and nodularin in shellfish, algal supplement tablet powder, water and cyanobacteria. The method provides a valuable early warning tool for the rapid, routine extraction and analysis of natural waters, cyanobacterial blooms, algal powders, food supplements and shellfish tissues, enabling monitoring labs to supplement traditional microscopy techniques and report toxicity results within a short timeframe of sample receipt. The new method, now accredited to ISO17025 standard, is simple, quick, applicable to multiple matrices and is highly suitable for use as a routine, high-throughout, fast turnaround regulatory monitoring tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Analysis of characteristics of Si in blast furnace pig iron and calibration methods in the detection by laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Mei, Yaguang; Cheng, Yuxin; Cheng, Shusen; Hao, Zhongqi; Guo, Lianbo; Li, Xiangyou; Zeng, Xiaoyan

    2017-10-01

    During the iron-making process in blast furnace, the Si content in liquid pig iron was usually used to evaluate the quality of liquid iron and thermal state of blast furnace. None effective method was found for rapid detecting the Si concentration of liquid iron. Laser-induced breakdown spectroscopy (LIBS) is a kind of atomic emission spectrometry technology based on laser ablation. Its obvious advantage is realizing rapid, in-situ, online analysis of element concentration in open air without sample pretreatment. The characteristics of Si in liquid iron were analyzed from the aspect of thermodynamic theory and metallurgical technology. The relationship between Si and C, Mn, S, P or other alloy elements were revealed based on thermodynamic calculation. Subsequently, LIBS was applied on rapid detection of Si of pig iron in this work. During LIBS detection process, several groups of standard pig iron samples were employed in this work to calibrate the Si content in pig iron. The calibration methods including linear, quadratic and cubic internal standard calibration, multivariate linear calibration and partial least squares (PLS) were compared with each other. It revealed that the PLS improved by normalization was the best calibration method for Si detection by LIBS.

  12. Rapid-viability PCR method for detection of live, virulent Bacillus anthracis in environmental samples.

    PubMed

    Létant, Sonia E; Murphy, Gloria A; Alfaro, Teneile M; Avila, Julie R; Kane, Staci R; Raber, Ellen; Bunt, Thomas M; Shah, Sanjiv R

    2011-09-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples.

  13. A semi-automated method for rapid detection of ripple events on interictal voltage discharges in the scalp electroencephalogram

    PubMed Central

    Chu, Catherine. J.; Chan, Arthur; Song, Dan; Staley, Kevin J.; Stufflebeam, Steven M.; Kramer, Mark A.

    2017-01-01

    Summary Background High frequency oscillations are emerging as a clinically important indicator of epileptic networks. However, manual detection of these high frequency oscillations is difficult, time consuming, and subjective, especially in the scalp EEG, thus hindering further clinical exploration and application. Semi-automated detection methods augment manual detection by reducing inspection to a subset of time intervals. We propose a new method to detect high frequency oscillations that co-occur with interictal epileptiform discharges. New Method The new method proceeds in two steps. The first step identifies candidate time intervals during which high frequency activity is increased. The second step computes a set of seven features for each candidate interval. These features require that the candidate event contain a high frequency oscillation approximately sinusoidal in shape, with at least three cycles, that co-occurs with a large amplitude discharge. Candidate events that satisfy these features are stored for validation through visual analysis. Results We evaluate the detector performance in simulation and on ten examples of scalp EEG data, and show that the proposed method successfully detects spike-ripple events, with high positive predictive value, low false positive rate, and high intra-rater reliability. Comparison with Existing Method The proposed method is less sensitive than the existing method of visual inspection, but much faster and much more reliable. Conclusions Accurate and rapid detection of high frequency activity increases the clinical viability of this rhythmic biomarker of epilepsy. The proposed spike-ripple detector rapidly identifies candidate spike-ripple events, thus making clinical analysis of prolonged, multielectrode scalp EEG recordings tractable. PMID:27988323

  14. Fabricated nanogap-rich plasmonic nanostructures through an optothermal surface bubble in a droplet.

    PubMed

    Karim, Farzia; Vasquez, Erick S; Zhao, Chenglong

    2018-01-15

    A rapid and cost-effective method for the fabrication of nanogap-rich structures is demonstrated in this Letter. The method utilizes the Marangoni convection around an optothermal surface bubble inside a liquid droplet with a nanoliter volume. The liquid droplet containing metallic nanoparticles reduces the sample consumption and confines the liquid flow. The optothermal surface bubble creates a strong convective flow that allows for the rapid deposition of the metallic nanoparticles to form nanogap-rich structures on any substrate under ambient conditions. This method will enable a broad range of applications such as biosensing, environmental analysis, and nonlinear optics.

  15. Methods for comparative evaluation of propulsion system designs for supersonic aircraft

    NASA Technical Reports Server (NTRS)

    Tyson, R. M.; Mairs, R. Y.; Halferty, F. D., Jr.; Moore, B. E.; Chaloff, D.; Knudsen, A. W.

    1976-01-01

    The propulsion system comparative evaluation study was conducted to define a rapid, approximate method for evaluating the effects of propulsion system changes for an advanced supersonic cruise airplane, and to verify the approximate method by comparing its mission performance results with those from a more detailed analysis. A table look up computer program was developed to determine nacelle drag increments for a range of parametric nacelle shapes and sizes. Aircraft sensitivities to propulsion parameters were defined. Nacelle shapes, installed weights, and installed performance was determined for four study engines selected from the NASA supersonic cruise aircraft research (SCAR) engine studies program. Both rapid evaluation method (using sensitivities) and traditional preliminary design methods were then used to assess the four engines. The method was found to compare well with the more detailed analyses.

  16. Rapid identification of oral Actinomyces species cultivated from subgingival biofilm by MALDI-TOF-MS

    PubMed Central

    Stingu, Catalina S.; Borgmann, Toralf; Rodloff, Arne C.; Vielkind, Paul; Jentsch, Holger; Schellenberger, Wolfgang; Eschrich, Klaus

    2015-01-01

    Background Actinomyces are a common part of the residential flora of the human intestinal tract, genitourinary system and skin. Isolation and identification of Actinomyces by conventional methods is often difficult and time consuming. In recent years, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has become a rapid and simple method to identify bacteria. Objective The present study evaluated a new in-house algorithm using MALDI-TOF-MS for rapid identification of different species of oral Actinomyces cultivated from subgingival biofilm. Design Eleven reference strains and 674 clinical strains were used in this study. All the strains were preliminarily identified using biochemical methods and then subjected to MALDI-TOF-MS analysis using both similarity-based analysis and classification methods (support vector machine [SVM]). The genotype of the reference strains and of 232 clinical strains was identified by sequence analysis of the 16S ribosomal RNA (rRNA). Results The sequence analysis of the 16S rRNA gene of all references strains confirmed their previous identification. The MALDI-TOF-MS spectra obtained from the reference strains and the other clinical strains undoubtedly identified as Actinomyces by 16S rRNA sequencing were used to create the mass spectra reference database. Already a visual inspection of the mass spectra of different species reveals both similarities and differences. However, the differences between them are not large enough to allow a reliable differentiation by similarity analysis. Therefore, classification methods were applied as an alternative approach for differentiation and identification of Actinomyces at the species level. A cross-validation of the reference database representing 14 Actinomyces species yielded correct results for all species which were represented by more than two strains in the database. Conclusions Our results suggest that a combination of MALDI-TOF-MS with powerful classification algorithms, such as SVMs, provide a useful tool for the differentiation and identification of oral Actinomyces. PMID:25597306

  17. Comparison of rapid methods for chemical analysis of milligram samples of ultrafine clays

    USGS Publications Warehouse

    Rettig, S.L.; Marinenko, J.W.; Khoury, Hani N.; Jones, B.F.

    1983-01-01

    Two rapid methods for the decomposition and chemical analysis of clays were adapted for use with 20–40-mg size samples, typical amounts of ultrafine products (≤0.5-µm diameter) obtained by modern separation methods for clay minerals. The results of these methods were compared with those of “classical” rock analyses. The two methods consisted of mixed lithium metaborate fusion and heated decomposition with HF in a closed vessel. The latter technique was modified to include subsequent evaporation with concentrated H2SO4 and re-solution in HCl, which reduced the interference of the fluoride ion in the determination of Al, Fe, Ca, Mg, Na, and K. Results from the two methods agree sufficiently well with those of the “classical” techniques to minimize error in the calculation of clay mineral structural formulae. Representative maximum variations, in atoms per unit formula of the smectite type based on 22 negative charges, are 0.09 for Si, 0.03 for Al, 0.015 for Fe, 0.07 for Mg, 0.03 for Na, and 0.01 for K.

  18. Feasibility for direct rapid energy dispersive X-ray fluorescence (EDXRF) and scattering analysis of complex matrix liquids by partial least squares.

    PubMed

    Angeyo, K H; Gari, S; Mustapha, A O; Mangala, J M

    2012-11-01

    The greatest challenge to material characterization by XRF technique is encountered in direct trace analysis of complex matrices. We exploited partial least squares (PLS) in conjunction with energy dispersive X-ray fluorescence and scattering (EDXRFS) spectrometry to rapidly (200 s) analyze lubricating oils. The PLS-EDXRFS method affords non-invasive quality assurance (QA) analysis of complex matrix liquids as it gave optimistic results for both heavy- and low-Z metal additives. Scatter peaks may further be used for QA characterization via the light elements. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Development of a rapid and sensitive HPLC method for the identification and quantification of cavoxin and cavoxone in Phoma cava culture filtrates.

    PubMed

    Masi, Marco; Moeini, Seyed Arash; Boari, Angela; Cimmino, Alessio; Vurro, Maurizio; Evidente, Antonio

    2018-07-01

    Cavoxin is a tetrasubstituted phytotoxic chalcone and cavoxone is the corresponding chroman-4-one, both produced in vitro by Phoma cava, a fungus isolated from chestnut. Cavoxin showed biofungicide potential against fungal species responsible for food moulding. Therefore, cavoxin has potential to be incorporated into biopolymer to generate 'intelligent food packaging'. To reach this objective, large-scale production of cavoxin by P. cava fermentation needs to be optimized. A rapid and efficient method for cavoxin analysis, as well as of cavoxone, in the fungal culture filtrates and the corresponding organic extracts is the first experimental step. Thus, a HPLC method was developed and applied to quantify cavoxin and cavoxone production in two different fungal culture conditions. The analysis proved that cavoxin production in stirred culture filtrates is significantly higher than in static ones.

  20. Rapid analysis of fertilizers by the direct-reading thermometric method.

    PubMed

    Sajó, I; Sipos, B

    1972-05-01

    The authors have developed rapid methods for the determination of the main components of fertilizers, namely phosphate, potassium and nitrogen fixed in various forms. In the absence of magnesium ions phosphate is precipitated with magnesia mixture; in the presence of magnesium ions ammonium phosphomolybdate is precipitated and the excess of molybdate is reacted with hydrogen peroxide. Potassium is determined by precipitation with silico-fluoride. For nitrogen fixed as ammonium salts the ammonium ions are condensed in a basic solution with formalin to hexamethylenetetramine; for nitrogen fixed as carbamide the latter is decomposed with sodium nitrite; for nitrogen fixed as nitrate the latter is reduced with titanium(III). In each case the temperature change of the test solution is measured. Practically all essential components of fertilizers may be determined by direct-reading thermometry; with this method and special apparatus the time of analysis is reduced to at most about 15 min for any determination.

  1. Detection of biomarkers of pathogenic Naegleria fowleri through mass spectrometry and proteomics.

    PubMed

    Moura, Hercules; Izquierdo, Fernando; Woolfitt, Adrian R; Wagner, Glauber; Pinto, Tatiana; del Aguila, Carmen; Barr, John R

    2015-01-01

    Emerging methods based on mass spectrometry (MS) can be used in the rapid identification of microorganisms. Thus far, these practical and rapidly evolving methods have mainly been applied to characterize prokaryotes. We applied matrix-assisted laser-desorption-ionization-time-of-flight mass spectrometry MALDI-TOF MS in the analysis of whole cells of 18 N. fowleri isolates belonging to three genotypes. Fourteen originated from the cerebrospinal fluid or brain tissue of primary amoebic meningoencephalitis patients and four originated from water samples of hot springs, rivers, lakes or municipal water supplies. Whole Naegleria trophozoites grown in axenic cultures were washed and mixed with MALDI matrix. Mass spectra were acquired with a 4700 TOF-TOF instrument. MALDI-TOF MS yielded consistent patterns for all isolates examined. Using a combination of novel data processing methods for visual peak comparison, statistical analysis and proteomics database searching we were able to detect several biomarkers that can differentiate all species and isolates studied, along with common biomarkers for all N. fowleri isolates. Naegleria fowleri could be easily separated from other species within the genus Naegleria. A number of peaks detected were tentatively identified. MALDI-TOF MS fingerprinting is a rapid, reproducible, high-throughput alternative method for identifying Naegleria isolates. This method has potential for studying eukaryotic agents. © 2014 The Author(s) Journal of Eukaryotic Microbiology © 2014 International Society of Protistologists.

  2. Genetic Comparison of B. Anthracis and its Close Relatives Using AFLP and PCR Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, P.J.; Hill, K.K.; Laker, M.T.

    1999-02-01

    Amplified Fragment length Polymorphism (AFLP) analysis allows a rapid, relatively simple analysis of a large portion of a microbial genome, providing information about the species and its phylogenetic relationship to other microbes (Vos, et al., 1995). The method simply surveys the genome for length and sequence polymorphisms. The pattern identified can be used for comparison to the genomes of other species. Unlike other methods, it does not rely on analysis of a single genetic locus that may bias the interpretation of results and it does not require any prior knowledge of the targeted organism. Moreover, a standard set of reagentsmore » can be applied to any species without using species-specific information or molecular probes. The authors are using AFLP's to rapidly identify different bacterial species. A comparison of AFLP profiles generated from a large battery of B. anthracis strains shows very little variability among different isolates (Keim, et al., 1997). By contrast, there is a significant difference between AFLP profiles generated for any B. anthracis strain and even the most closely related Bacillus species. Sufficient variability is apparent among all known microbial species to allow phylogenetic analysis based on large numbers of genetically unlinked loci. These striking differences among AFLP profiles allow unambiguous identification of previously identified species and phylogenetic placement of newly characterized isolates relative to known species based on a large number of independent genetic loci. Data generated thus far show that the method provides phylogenetic analyses that are consistent with other widely accepted phylogenetic methods. However, AFLP analysis provides a more detailed analysis of the targets and samples a much larger portion of the genome. Consequently, it provides an inexpensive, rapid means of characterizing microbial isolates to further differentiate among strains and closely related microbial species. Such information cannot be rapidly generated by other means. AFLP sample analysis quickly generates a very large amount of molecular information about microbial genomes. However, this information cannot be analyzed rapidly using manual methods. The authors are developing a large archive of electronic AFLP signatures that is being used to identify isolates collected from medical, veterinary, forensic and environmental samples. They are also developing the computational packages necessary to rapidly and unambiguously analyze the AFLP profiles and conduct a phylogenetic comparison of these data relative to information already in the database. They will use this archive and the associated algorithms to determine the species identity of previously uncharacterized isolates and place them phylogenetically relative to other microbes based on their AFLP signatures. This study provides significant new information about microbes with environmental, veterinary and medical significance. This information can be used in further studies to understand the relationships among these species and the factors that distinguish them from one another. It should also allow identification of unique factors that contribute to important microbial traits including pathogenicity and virulence. They are also using AFLP data to identify, isolate and sequence DNA fragments that are unique to particular microbial species and strains. The fragment patterns and sequence information provide insights into the complexity and organization of bacterial genomes relative to one another. They also provide the information necessary for development of species-specific PCR primers that can be used to interrogate complex samples for the presence of B. anthracis, other microbial pathogens or their remnants.« less

  3. Real-time PCR and NASBA for rapid and sensitive detection of Vibrio cholerae in ballast water.

    PubMed

    Fykse, Else M; Nilsen, Trine; Nielsen, Agnete Dessen; Tryland, Ingun; Delacroix, Stephanie; Blatny, Janet M

    2012-02-01

    Transport of ballast water is one major factor in the transmission of aquatic organisms, including pathogenic bacteria. The IMO-guidelines of the Convention for the Control and Management of Ships' Ballast Water and Sediments, states that ships are to discharge <1 CFU per 100 ml ballast water of toxigenic Vibrio cholerae, emphasizing the need to establish test methods. To our knowledge, there are no methods sensitive and rapid enough available for cholera surveillance of ballast water. In this study real-time PCR and NASBA methods have been evaluated to specifically detect 1 CFU/100ml of V. cholerae in ballast water. Ballast water samples spiked with V. cholerae cells were filtered and enriched in alkaline peptone water before PCR or NASBA detection. The entire method, including sample preparation and analysis was performed within 7 h, and has the potential to be used for analysis of ballast water for inspection and enforcement control. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Development of a micropulverized extraction method for rapid toxicological analysis of methamphetamine in hair.

    PubMed

    Miyaguchi, Hajime; Kakuta, Masaya; Iwata, Yuko T; Matsuda, Hideaki; Tazawa, Hidekatsu; Kimura, Hiroko; Inoue, Hiroyuki

    2007-09-07

    We developed a rapid sample preparation method for the toxicological analysis of methamphetamine and amphetamine (the major metabolite of methamphetamine) in human hair by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), to facilitate fast screening and quantitation. Two milligrams of hair were mechanically micropulverized for 5 min in a 2-ml plastic tube together with 100 microl of an aqueous solvent containing 10% acetonitrile, 100 mM trifluoroacetic acid and the corresponding deuterium analogues as internal standards. The pulverizing highly disintegrated the hair components, simultaneously allowing the extraction of any drugs present in the hair. After filtering the suspension with a membrane-filter unit, the clear filtrate was directly analyzed by HPLC-MS/MS. No evaporation processes were required for sample preparation. Method optimization and validation study were carried out using real-case specimens and fortified samples in which the drugs had been artificially absorbed, respectively. Concentration ranges for quantitation were 0.040-125 and 0.040-25 ng/mg for methamphetamine and amphetamine, respectively. Real-case specimens were analyzed by the method presented here and by conventional ones to verify the applicability of our method to real-world analysis. Our method took less than 30 min for a set of chromatograms to be obtained from a washed hair sample.

  5. Rapid enantiomeric separation and simultaneous determination of phenethylamines by ultra high performance liquid chromatography with fluorescence and mass spectrometric detection: application to the analysis of illicit drugs distributed in the Japanese market and biological samples.

    PubMed

    Inagaki, Shinsuke; Hirashima, Haruo; Taniguchi, Sayuri; Higashi, Tatsuya; Min, Jun Zhe; Kikura-Hanajiri, Ruri; Goda, Yukihiro; Toyo'oka, Toshimasa

    2012-12-01

    A rapid enantiomeric separation and simultaneous determination method based on ultra high performance liquid chromatography (UHPLC) was developed for phenethylamine-type abused drugs using (R)-(-)-4-(N,N-dimethylaminosulfonyl)-7-(3-isothiocyanatopyrrolidin-1-yl)-2,1,3-benzoxadiazole ((R)-(-)-DBD-Py-NCS) as the chiral fluorescent derivatization reagent. The derivatives were rapidly enantiomerically separated by reversed-phase UHPLC using a column of 2.3-µm octadecylsilica (ODS) particles by isocratic elution with water-methanol or water-acetonitrile systems as the mobile phase. The proposed method was applied to the analysis of products containing illicit drugs distributed in the Japanese market. Among the products, 1-(3,4-methylenedioxyphenyl)butan-2-amine (BDB) and 1-(2-methoxy4,5-methylenedioxyphenyl)propan-2-amine (MMDA-2) were detected in racemic form. Furthermore, the method was successfully applied to the analysis of hair specimens from rats that were continuously dosed with diphenyl(pyrrolidin-2-yl)methanol (D2PM). Using UHPLC-fluorescence (FL) detection, (R)- and (S)-D2PM from hair specimens were enantiomerically separated and detected with high sensitivity. The detection limits of (R)- and (S)-D2PM were 0.12 and 0.21 ng/mg hair, respectively (signal-to-noise ratio (S/N) = 3). Copyright © 2012 John Wiley & Sons, Ltd.

  6. GC/IR computer-aided identification of anaerobic bacteria

    NASA Astrophysics Data System (ADS)

    Ye, Hunian; Zhang, Feng S.; Yang, Hua; Li, Zhu; Ye, Song

    1993-09-01

    A new method was developed to identify anaerobic bacteria by using pattern recognition. The method is depended on GC / JR data. The system is intended for use as a precise rapid and reproduceable aid in the identification of unknown isolates. Key Words: Anaerobic bacteria Pattern recognition Computeraided identification GC / JR 1 . TNTRODUCTTON A major problem in the field of anaerobic bacteriology is the difficulty in accurately precisely and rapidly identifying unknown isolates. Tn the proceedings of the Third International Symposium on Rapid Methods and Automation in Microbiology C. M. Moss said: " Chromatographic analysis is a new future for clinical microbiology" . 12 years past and so far it seems that this is an idea whose time has not get come but it close. Now two major advances that have brought the technology forword in terms ofmaking it appropriate for use in the clinical laboratory can aldo be cited. One is the development and implementation of fused silica capillary columns. In contrast to packed columns and those of'' greater width these columns allow reproducible recovery of hydroxey fatty acids with the same carbon chain length. The second advance is the efficient data processing afforded by modern microcomputer systems. On the other hand the practical steps for sample preparation also are an advance in the clinical laboratory. Chromatographic Analysis means mainly of analysis of fatty acids. The most common

  7. Green Curriculum Analysis in Technological Education

    ERIC Educational Resources Information Center

    Chakraborty, Arpita; Singh, Manvendra Pratap; Roy, Mousumi

    2018-01-01

    With rapid industrialization and technological development, India is facing adverse affects of unsustainable pattern of production and consumption. Education for sustainable development has been widely recognized to reduce the threat of environmental degradation and resource depletion. This paper used the content analysis method to explore the…

  8. Electrochemical biosensors for Salmonella: State of the art and challenges in food safety assessment.

    PubMed

    Silva, Nádia F D; Magalhães, Júlia M C S; Freire, Cristina; Delerue-Matos, Cristina

    2018-01-15

    According to the recent statistics, Salmonella is still an important public health issue in the whole world. Legislated reference methods, based on counting plate methods, are sensitive enough but are inadequate as an effective emergency response tool, and are far from a rapid device, simple to use out of lab. An overview of the commercially available rapid methods for Salmonella detection is provided along with a critical discussion of their limitations, benefits and potential use in a real context. The distinguished potentialities of electrochemical biosensors for the development of rapid devices are highlighted. The state-of-art and the newest technologic approaches in electrochemical biosensors for Salmonella detection are presented and a critical analysis of the literature is made in an attempt to identify the current challenges towards a complete solution for Salmonella detection in microbial food control based on electrochemical biosensors. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Direct Detection of Pharmaceuticals and Personal Care Products from Aqueous Samples with Thermally-Assisted Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Campbell, Ian S.; Ton, Alain T.; Mulligan, Christopher C.

    2011-07-01

    An ambient mass spectrometric method based on desorption electrospray ionization (DESI) has been developed to allow rapid, direct analysis of contaminated water samples, and the technique was evaluated through analysis of a wide array of pharmaceutical and personal care product (PPCP) contaminants. Incorporating direct infusion of aqueous sample and thermal assistance into the source design has allowed low ppt detection limits for the target analytes in drinking water matrices. With this methodology, mass spectral information can be collected in less than 1 min, consuming ~100 μL of total sample. Quantitative ability was also demonstrated without the use of an internal standard, yielding decent linearity and reproducibility. Initial results suggest that this source configuration is resistant to carryover effects and robust towards multi-component samples. The rapid, continuous analysis afforded by this method offers advantages in terms of sample analysis time and throughput over traditional hyphenated mass spectrometric techniques.

  10. Direct detection of pharmaceuticals and personal care products from aqueous samples with thermally-assisted desorption electrospray ionization mass spectrometry.

    PubMed

    Campbell, Ian S; Ton, Alain T; Mulligan, Christopher C

    2011-07-01

    An ambient mass spectrometric method based on desorption electrospray ionization (DESI) has been developed to allow rapid, direct analysis of contaminated water samples, and the technique was evaluated through analysis of a wide array of pharmaceutical and personal care product (PPCP) contaminants. Incorporating direct infusion of aqueous sample and thermal assistance into the source design has allowed low ppt detection limits for the target analytes in drinking water matrices. With this methodology, mass spectral information can be collected in less than 1 min, consuming ~100 μL of total sample. Quantitative ability was also demonstrated without the use of an internal standard, yielding decent linearity and reproducibility. Initial results suggest that this source configuration is resistant to carryover effects and robust towards multi-component samples. The rapid, continuous analysis afforded by this method offers advantages in terms of sample analysis time and throughput over traditional hyphenated mass spectrometric techniques.

  11. Classification of Fusarium-Infected Korean Hulled Barley Using Near-Infrared Reflectance Spectroscopy and Partial Least Squares Discriminant Analysis

    PubMed Central

    Lim, Jongguk; Kim, Giyoung; Mo, Changyeun; Oh, Kyoungmin; Yoo, Hyeonchae; Ham, Hyeonheui; Kim, Moon S.

    2017-01-01

    The purpose of this study is to use near-infrared reflectance (NIR) spectroscopy equipment to nondestructively and rapidly discriminate Fusarium-infected hulled barley. Both normal hulled barley and Fusarium-infected hulled barley were scanned by using a NIR spectrometer with a wavelength range of 1175 to 2170 nm. Multiple mathematical pretreatments were applied to the reflectance spectra obtained for Fusarium discrimination and the multivariate analysis method of partial least squares discriminant analysis (PLS-DA) was used for discriminant prediction. The PLS-DA prediction model developed by applying the second-order derivative pretreatment to the reflectance spectra obtained from the side of hulled barley without crease achieved 100% accuracy in discriminating the normal hulled barley and the Fusarium-infected hulled barley. These results demonstrated the feasibility of rapid discrimination of the Fusarium-infected hulled barley by combining multivariate analysis with the NIR spectroscopic technique, which is utilized as a nondestructive detection method. PMID:28974012

  12. A rapid method for simultaneous quantification of 13 sugars and sugar alcohols in food products by UPLC-ELSD.

    PubMed

    Koh, Dong-Wan; Park, Jae-Woong; Lim, Jung-Hoon; Yea, Myeong-Jai; Bang, Dae-Young

    2018-02-01

    A novel, rapid, simultaneous analysis method for five sugars (fructose, glucose, sucrose, maltose, and lactose) and eight sugar alcohols (erythritol, xylitol, sorbitol, mannitol, inositol, maltitol, lactitol, and isomalt) was developed using UPLC-ELSD, without derivatization. The analysis conditions, including the gradient conditions, modifier concentration and column length, were optimized. Thirteen sugars and sugar alcohols were separated well and the resolution of their peaks was above 1.0. Their optimum analysis condition can be analyzed within 15min. Standard curves for sugars and sugar alcohols with concentrations of 5.0-0.1% and 2.0-0.05% are presented herein, and their correlation coefficients are found to be above 0.999 and the limit of detection (LOD) was around 0.006-0.018%. This novel analysis system can be used for foodstuffs such as candy, chewing gum, jelly, chocolate, processed chocolate products, and snacks containing 0.21-46.41% of sugars and sugar alcohols. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Characterization and Differentiation of Petroleum-Derived Products by E-Nose Fingerprints

    PubMed Central

    Ferreiro-González, Marta; Palma, Miguel; Ayuso, Jesús; Álvarez, José A.; Barroso, Carmelo G.

    2017-01-01

    Characterization of petroleum-derived products is an area of continuing importance in environmental science, mainly related to fuel spills. In this study, a non-separative analytical method based on E-Nose (Electronic Nose) is presented as a rapid alternative for the characterization of several different petroleum-derived products including gasoline, diesel, aromatic solvents, and ethanol samples, which were poured onto different surfaces (wood, cork, and cotton). The working conditions about the headspace generation were 145 °C and 10 min. Mass spectroscopic data (45–200 m/z) combined with chemometric tools such as hierarchical cluster analysis (HCA), later principal component analysis (PCA), and finally linear discriminant analysis (LDA) allowed for a full discrimination of the samples. A characteristic fingerprint for each product can be used for discrimination or identification. The E-Nose can be considered as a green technique, and it is rapid and easy to use in routine analysis, thus providing a good alternative to currently used methods. PMID:29113069

  14. A rapid screen for four corticosteroids in equine synovial fluid.

    PubMed

    Agrawal, Karan; Ebel, Joseph G; Bischoff, Karyn

    2014-06-01

    Most antidoping method development in the equine industry has been for plasma and urine, though there has been recent interest in the analysis of synovial fluid for evidence of doping by intra-articular corticosteroid injection. Published methods for corticosteroid analysis in synovial fluid are primarily singleplex methods, do not screen for all corticosteroids of interest and are not adequately sensitive. The purpose of this study is to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) screening method for the detection of four of the most common intra-articularly administered corticosteroids--betamethasone, methylprednisolone, methylprednisolone acetate and triamcinolone acetonide. Sample preparation consisted of protein precipitation followed by a basified liquid-liquid extraction. LC-MS-MS experiments consisted of a six-min isocratic separation using a Phenomenex Polar-RP stationary phase and a mobile phase consisting of 35% acetonitrile, 5 mM ammonium acetate and 0.1% formic acid in nanopure water. The detection system used was a triple quadrupole mass analyzer with thermospray ionization, and compounds were identified using selective reaction monitoring. The method was validated to the ISO/IEC 17025 standard, and real synovial fluid samples were analyzed to demonstrate the application of the method in an antidoping context. The method was highly selective for the four corticosteroids with limits of detection of 1-3 ng/mL. The extraction efficiency was 50-101%, and the matrix effects were 14-31%. These results indicate that the method is a rapid and sensitive screen for the four corticosteroids in equine synovial fluid, fit for purpose for equine antidoping assays.

  15. Differentiation of five enterohepatic Helicobacter species by nested PCR with high-resolution melting curve analysis.

    PubMed

    Wu, Miaoli; Rao, Dan; Zhu, Yujun; Wang, Jing; Yuan, Wen; Zhang, Yu; Huang, Ren; Guo, Pengju

    2017-04-01

    Enterohepatic Helicobacter species (EHS) are widespread in rodent species around the world. Several studies have demonstrated that infection with EHS can interfere with the outcomes of animal experiments in cancer research and significantly influence the study results. Therefore, it is essential to establish a rapid detection and identification of EHS for biomedical research using laboratory rodents. Our study aimed to develop a rapid and sensitive method to detect and distinguish five enterohepatic Helicobacter species. Nested PCR followed by high-resolution melting curve analysis (HRM) was developed for identification of H. bilis, H. rodentium, H. muridarum, H. typhlonius, as well as H. hepaticus. To validate the accuracy of nested PCR-HRM analysis, quantitative real-time PCR methods for five different enterohepatic Helicobacter species were developed. A total of 50 cecal samples were tested using both nested PCR-HRM analysis and qPCR method. The nested PCR-HRM method could distinguish five enterohepatic Helicobacter species by different melting temperatures. The melting curve were characterized by peaks of 78.7 ± 0.12°C for H. rodentium, 80.51 ± 0.09°C for H. bilis, 81.6 ± 0.1°C for H. typhlonius, 82.11 ± 0.18°C for H. muridarum, and 82.95 ± 0.09°C for H. hepaticus. The nested PCR-HRM assay is a simple, rapid, and cost-effective assay. This assay could be a useful tool for molecular epidemiology study of enterohepatic Helicobacter infection and an attractive alternative for genotyping of enterohepatic Helicobacter species. © 2016 John Wiley & Sons Ltd.

  16. [Prediction of the side-cut product yield of atmospheric/vacuum distillation unit by NIR crude oil rapid assay].

    PubMed

    Wang, Yan-Bin; Hu, Yu-Zhong; Li, Wen-Le; Zhang, Wei-Song; Zhou, Feng; Luo, Zhi

    2014-10-01

    In the present paper, based on the fast evaluation technique of near infrared, a method to predict the yield of atmos- pheric and vacuum line was developed, combined with H/CAMS software. Firstly, the near-infrared (NIR) spectroscopy method for rapidly determining the true boiling point of crude oil was developed. With commercially available crude oil spectroscopy da- tabase and experiments test from Guangxi Petrochemical Company, calibration model was established and a topological method was used as the calibration. The model can be employed to predict the true boiling point of crude oil. Secondly, the true boiling point based on NIR rapid assay was converted to the side-cut product yield of atmospheric/vacuum distillation unit by H/CAMS software. The predicted yield and the actual yield of distillation product for naphtha, diesel, wax and residual oil were compared in a 7-month period. The result showed that the NIR rapid crude assay can predict the side-cut product yield accurately. The near infrared analytic method for predicting yield has the advantages of fast analysis, reliable results, and being easy to online operate, and it can provide elementary data for refinery planning optimization and crude oil blending.

  17. Nonlethal evaluation of the physiological health of unionid mussels: Method for biopsy and glycogen analysis

    USGS Publications Warehouse

    Naimo, T.J.; Damschen, E.D.; Rada, R.G.; Monroe, E.M.

    1998-01-01

    In long-lived unionid mussels, many short-term measures of growth are of limited value. Changes in physiological condition may be an early indication of stress, because the increased energy demand associated with stress often results in a depletion of glycogen reserves, the principal storage form of carbohydrates in unionid mussels. Our goal was to nonlethally extract tissue from freshwater mussels and then to develop a rapid and dependable method for the analysis of glycogen in the tissue extracts. A biopsy technique was developed to remove between 5 and 10 mg of food tissue in Amblema plicata plicata. The survival rate did not differ between biopsied and non-biopsied mussels during a 581-d observation period, demonstrating that the biopsy technique will allow nonlethal evaluation of the physiological condition of individual mussels through measurement of changes in contaminant, genetic, and biochemical indicators in tissue. We also modified the standard alkaline digestion and phenol-sulfuric acid analysis of glycogen for use on the small samples of biopsied tissue and to reduce analysis time and cost. We present quality control data, including method detection limits and estimates of precision and bias. The modified analytical method is rapid and accurate and has a method detection limit of 0.014 mg glycogen. Glycogen content in the biopsied samples was well above the method detection limit; it ranged from 0.09 to 0.36 mg, indicating that the method should be applicable to native mussels.

  18. Rapid quantification of underivatized amino acids in plasma by hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass-spectrometry.

    PubMed

    Prinsen, Hubertus C M T; Schiebergen-Bronkhorst, B G M; Roeleveld, M W; Jans, J J M; de Sain-van der Velden, M G M; Visser, G; van Hasselt, P M; Verhoeven-Duif, N M

    2016-09-01

    Amino acidopathies are a class of inborn errors of metabolism (IEM) that can be diagnosed by analysis of amino acids (AA) in plasma. Current strategies for AA analysis include cation exchange HPLC with post-column ninhydrin derivatization, GC-MS, and LC-MS/MS-related methods. Major drawbacks of the current methods are time-consuming procedures, derivative problems, problems with retention, and MS-sensitivity. The use of hydrophilic interaction liquid chromatography (HILIC) columns is an ideal separation mode for hydrophilic compounds like AA. Here we report a HILIC-method for analysis of 36 underivatized AA in plasma to detect defects in AA metabolism that overcomes the major drawbacks of other methods. A rapid, sensitive, and specific method was developed for the analysis of AA in plasma without derivatization using HILIC coupled with tandem mass-spectrometry (Xevo TQ, Waters). Excellent separation of 36 AA (24 quantitative/12 qualitative) in plasma was achieved on an Acquity BEH Amide column (2.1×100 mm, 1.7 μm) in a single MS run of 18 min. Plasma of patients with a known IEM in AA metabolism was analyzed and all patients were correctly identified. The reported method analyzes 36 AA in plasma within 18 min and provides baseline separation of isomeric AA such as leucine and isoleucine. No separation was obtained for isoleucine and allo-isoleucine. The method is applicable to study defects in AA metabolism in plasma.

  19. A novel method for rapid determination of total solid content in viscous liquids by multiple headspace extraction gas chromatography.

    PubMed

    Xin, Li-Ping; Chai, Xin-Sheng; Hu, Hui-Chao; Barnes, Donald G

    2014-09-05

    This work demonstrates a novel method for rapid determination of total solid content in viscous liquid (polymer-enriched) samples. The method is based multiple headspace extraction gas chromatography (MHE-GC) on a headspace vial at a temperature above boiling point of water. Thus, the trend of water loss from the tested liquid due to evaporation can be followed. With the limited MHE-GC testing (e.g., 5 extractions) and a one-point calibration procedure (i.e., recording the weight difference before and after analysis), the total amount of water in the sample can be determined, from which the total solid contents in the liquid can be calculated. A number of black liquors were analyzed by the new method which yielded results that closely matched those of the reference method; i.e., the results of these two methods differed by no more than 2.3%. Compared with the reference method, the MHE-GC method is much simpler and more practical. Therefore, it is suitable for the rapid determination of the solid content in many polymer-containing liquid samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Rapid estimation of microbial populations in fish samples by using terminal restriction fragment length polymorphism analysis of 16S rDNA.

    PubMed

    Tanaka, Yuichiro; Takahashi, Hajime; Kitazawa, Nao; Kimura, Bon

    2010-01-01

    A rapid system using terminal restriction fragment length polymorphism (T-RFLP) analysis targeting 16S rDNA is described for microbial population analysis in edible fish samples. The defined terminal restriction fragment database was constructed by collecting 102 strains of bacteria representing 53 genera that are associated with fish. Digestion of these 102 strains with two restriction enzymes, HhaI and MspI, formed 54 pattern groups with discrimination to the genus level. This T-RFLP system produced results comparable to those from a culture-based method in six natural fish samples with a qualitative correspondence of 71.4 to 92.3%. Using the T-RFLP system allowed an estimation of the microbial population within 7 h. Rapid assay of the microbial population is advantageous for food manufacturers and testing laboratories; moreover, the strategy presented here allows adaptation to specific testing applications.

  1. Analysis of drugs in human tissues by supercritical fluid extraction/immunoassay

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Sabucedo, Alberta; Rein, Joseph; Hearn, W. L.

    1997-02-01

    A rapid, readily automated method has been developed for the quantitative analysis of phenobarbital from human liver tissues based on supercritical carbon dioxide extraction followed by fluorescence enzyme immunoassay. The method developed significantly reduces sample handling and utilizes the entire liver homogenate. The current method yields comparable recoveries and precision and does not require the use of an internal standard, although traditional GC/MS confirmation can still be performed on sample extracts. Additionally, the proposed method uses non-toxic, inexpensive carbon dioxide, thus eliminating the use of halogenated organic solvents.

  2. Rapid regulation of nuclear proteins by rapamycin-induced translocation in fission yeast

    PubMed Central

    Ding, Lin; Laor, Dana; Weisman, Ronit; Forsburg, Susan L

    2014-01-01

    Genetic analysis of protein function requires a rapid means of inactivating the gene under study. Typically this exploits temperature sensitive mutations, or promoter shut-off techniques. We report the adaptation to Schizosaccharomyces pombe of the Anchor Away technique, originally designed in budding yeast (Haruki et al., 2008a). This method relies on a rapamycin-mediated interaction between the FRB and FKBP12 binding domains, to relocalize nuclear proteins of interest to the cytoplasm. We demonstrate a rapid nuclear depletion of abundant proteins as proof-of-principle. PMID:24733494

  3. Validation of a Rapid Bacteria Endospore Enumeration System for Planetary Protection Application

    NASA Astrophysics Data System (ADS)

    Chen, Fei; Kern, Roger; Kazarians, Gayane; Venkateswaran, Kasthuri

    NASA monitors spacecraft surfaces to assure that the presence of bacterial endospores meets strict criteria at launch, to minimize the risk of inadvertent contamination of the surface of Mars. Currently, the only approved method for enumerating the spores is a culture based assay that requires three days to produce results. In order to meet the demanding schedules of spacecraft assembly, a more rapid spore detection assay is being considered as an alternate method to the NASA standard culture-based assay. The Millipore Rapid Microbiology Detection System (RMDS) has been used successfully for rapid bioburden enumeration in the pharmaceutical and food industries. The RMDS is rapid and simple, shows high sensitivity (to 1 colony forming unit [CFU]/sample), and correlates well with traditional culture-based methods. It combines membrane filtration, adenosine triphosphate (ATP) bioluminescence chemistry, and image analysis based on photon detection with a Charge Coupled Device (CCD) camera. In this study, we have optimized the assay conditions and evaluated the use of the RMDS as a rapid spore detection tool for NASA applications. In order to select for spores, the samples were subjected to a heat shock step before proceeding with the RMDS incubation protocol. Seven species of Bacillus (nine strains) that have been repeatedly isolated from clean room environments were assayed. All strains were detected by the RMDS in 5 hours and these assay times were repeatedly demonstrated along with low image background noise. Validation experiments to compare the Rapid Sore Assay (RSA) and NASA standard assay (NSA) were also performed. The evaluation criteria were modeled after the FDA Guideline of Process Validation, and Analytical Test Methods. This body of research demonstrates that the Rapid Spore Assay (RSA) is quick, and of equivalent sensitivity to the NASA standard assay, potentially reducing the assay time for bacterial endospores from over 72 hours to less than 8 hours. Accordingly, JPL has produced a report recommending that NASA adopt the RSA method as a suitable alternative to the NASA standard assay.

  4. Rapid-estimation method for assessing scour at highway bridges

    USGS Publications Warehouse

    Holnbeck, Stephen R.

    1998-01-01

    A method was developed by the U.S. Geological Survey for rapid estimation of scour at highway bridges using limited site data and analytical procedures to estimate pier, abutment, and contraction scour depths. The basis for the method was a procedure recommended by the Federal Highway Administration for conducting detailed scour investigations, commonly referred to as the Level 2 method. Using pier, abutment, and contraction scour results obtained from Level 2 investigations at 122 sites in 10 States, envelope curves and graphical relations were developed that enable determination of scour-depth estimates at most bridge sites in a matter of a few hours. Rather than using complex hydraulic variables, surrogate variables more easily obtained in the field were related to calculated scour-depth data from Level 2 studies. The method was tested by having several experienced individuals apply the method in the field, and results were compared among the individuals and with previous detailed analyses performed for the sites. Results indicated that the variability in predicted scour depth among individuals applying the method generally was within an acceptable range, and that conservatively greater scour depths generally were obtained by the rapid-estimation method compared to the Level 2 method. The rapid-estimation method is considered most applicable for conducting limited-detail scour assessments and as a screening tool to determine those bridge sites that may require more detailed analysis. The method is designed to be applied only by a qualified professional possessing knowledge and experience in the fields of bridge scour, hydraulics, and flood hydrology, and having specific expertise with the Level 2 method.

  5. Fluorescence excitation-emission matrix (EEM) spectroscopy for rapid identification and quality evaluation of cell culture media components.

    PubMed

    Li, Boyan; Ryan, Paul W; Shanahan, Michael; Leister, Kirk J; Ryder, Alan G

    2011-11-01

    The application of fluorescence excitation-emission matrix (EEM) spectroscopy to the quantitative analysis of complex, aqueous solutions of cell culture media components was investigated. These components, yeastolate, phytone, recombinant human insulin, eRDF basal medium, and four different chemically defined (CD) media, are used for the formulation of basal and feed media employed in the production of recombinant proteins using a Chinese Hamster Ovary (CHO) cell based process. The comprehensive analysis (either identification or quality assessment) of these materials using chromatographic methods is time consuming and expensive and is not suitable for high-throughput quality control. The use of EEM in conjunction with multiway chemometric methods provided a rapid, nondestructive analytical method suitable for the screening of large numbers of samples. Here we used multiway robust principal component analysis (MROBPCA) in conjunction with n-way partial least squares discriminant analysis (NPLS-DA) to develop a robust routine for both the identification and quality evaluation of these important cell culture materials. These methods are applicable to a wide range of complex mixtures because they do not rely on any predetermined compositional or property information, thus making them potentially very useful for sample handling, tracking, and quality assessment in biopharmaceutical industries.

  6. Rapid screening of illicit additives in weight loss dietary supplements with desorption corona beam ionisation (DCBI) mass spectrometry.

    PubMed

    Wang, H; Wu, Y; Zhao, Y; Sun, W; Ding, L; Guo, B; Chen, B

    2012-08-01

    Desorption corona beam ionisation (DCBI), the relatively novel ambient mass spectrometry (MS) technique, was utilised to screen for illicit additives in weight-loss food. The five usually abused chemicals - fenfluramine, N-di-desmethyl sibutramine, N-mono-desmethyl sibutramine, sibutramine and phenolphthalein - were detected with the proposed DCBI-MS method. Fast single-sample and high-throughput analysis was demonstrated. Semi-quantification was accomplished based on peak areas in the ion chromatograms. Four illicit additives were identified and semi-quantified in commercial samples. As there was no tedious sample pre-treatment compared with conventional HPLC methods, high-throughput analysis was achieved with DCBI. The results proved that DCBI-MS is a powerful tool for the rapid screening of illicit additives in weight-loss dietary supplements.

  7. Rapid determination of actinides in asphalt samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2014-01-12

    A new rapid method for the determination of actinides in asphalt samples has been developed that can be used in emergency response situations or for routine analysis If a radiological dispersive device (RDD), Improvised Nuclear Device (IND) or a nuclear accident such as the accident at the Fukushima Nuclear Power Plant in March, 2011 occurs, there will be an urgent need for rapid analyses of many different environmental matrices, including asphalt materials, to support dose mitigation and environmental clean up. The new method for the determination of actinides in asphalt utilizes a rapid furnace step to destroy bitumen and organicsmore » present in the asphalt and sodium hydroxide fusion to digest the remaining sample. Sample preconcentration steps are used to collect the actinides and a new stacked TRU Resin + DGA Resin column method is employed to separate the actinide isotopes in the asphalt samples. The TRU Resin plus DGA Resin separation approach, which allows sequential separation of plutonium, uranium, americium and curium isotopes in asphalt samples, can be applied to soil samples as well.« less

  8. THE MULTIELEMENTAL ANALYSIS OF DRINKING WATER USING PROTON-INDUCED X-RAY EMISSION (PIXE)

    EPA Science Inventory

    A new, rapid, and economical method for the multielemental analysis of drinking water samples is described. The concentrations of 76 elements heavier than aluminum are determined using proton-induced x-ray emission (PIXE) technology. The concentration of sodium is evaluated using...

  9. Methods for Kinetic and Thermodynamic Analysis of Aminoacyl-tRNA Synthetases

    PubMed Central

    Francklyn, Christopher S.; First, Eric A.; Perona, John J.; Hou, Ya-Ming

    2008-01-01

    The accuracy of protein synthesis relies on the ability of aminoacyl-tRNA synthetases (aaRSs) to discriminate among true and near cognate substrates. To date, analysis of aaRSs function, including identification of residues of aaRS participating in amino acid and tRNA discrimination, has largely relied on the steady state kinetic pyrophosphate exchange and aminoacylation assays. Pre-steady state kinetic studies investigating a more limited set of aaRS systems have also been undertaken to assess the energetic contributions of individual enzyme-substrate interactions, particularly in the adenylation half reaction. More recently, a renewed interest in the use of rapid kinetics approaches for aaRSs has led to their application to several new aaRS systems, resulting in the identification of mechanistic differences that distinguish the two structurally distinct aaRS classes. Here, we review the techniques for thermodynamic and kinetic analysis of aaRS function. Following a brief survey of methods for the preparation of materials and for steady state kinetic analysis, this review will describe pre-steady state kinetic methods employing rapid quench and stopped-flow fluorescence for analysis of the activation and aminoacyl transfer reactions. Application of these methods to any aaRS system allows the investigator to derive detailed kinetic mechanisms for the activation and aminoacyl transfer reactions, permitting issues of substrate specificity, stereochemical mechanism, and inhibitor interaction to be addressed in a rigorous and quantitative fashion. PMID:18241792

  10. Stability indicating simplified HPLC method for simultaneous analysis of resveratrol and quercetin in nanoparticles and human plasma.

    PubMed

    Kumar, Sandeep; Lather, Viney; Pandita, Deepti

    2016-04-15

    Resveratrol and quercetin are well-known polyphenolic compounds present in common foods, which have demonstrated enormous potential in the treatment of a wide variety of diseases. Owing to their exciting synergistic potential and combination delivery applications, we developed a simple and rapid RP-HPLC method based on isosbestic point detection. The separation was carried out on phenomenex Synergi 4μ Hydro-RP 80A column using methanol: acetonitrile (ACN): 0.1% phosphoric acid (60:10:30) as mobile phase. The method was able to quantify nanograms of analytes simultaneously on a single wavelength (269 nm), making it highly sensitive, rapid as well as economical. Additionally, forced degradation studies of resveratrol and quercetin were established and the method's applicability was evaluated on PLGA nanoparticles and human plasma. The analytes peaks were found to be well resolved in the presence of degradation products and excipients. The simplicity of the developed method potentializes its suitability for routine in vitro and in vivo analysis of resveratrol and quercetin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Vesselness propagation: a fast interactive vessel segmentation method

    NASA Astrophysics Data System (ADS)

    Cai, Wenli; Dachille, Frank; Harris, Gordon J.; Yoshida, Hiroyuki

    2006-03-01

    With the rapid development of multi-detector computed tomography (MDCT), resulting in increasing temporal and spatial resolution of data sets, clinical use of computed tomographic angiography (CTA) is rapidly increasing. Analysis of vascular structures is much needed in CTA images; however, the basis of the analysis, vessel segmentation, can still be a challenging problem. In this paper, we present a fast interactive method for CTA vessel segmentation, called vesselness propagation. This method is a two-step procedure, with a pre-processing step and an interactive step. During the pre-processing step, a vesselness volume is computed by application of a CTA transfer function followed by a multi-scale Hessian filtering. At the interactive stage, the propagation is controlled interactively in terms of the priority of the vesselness. This method was used successfully in many CTA applications such as the carotid artery, coronary artery, and peripheral arteries. It takes less than one minute for a user to segment the entire vascular structure. Thus, the proposed method provides an effective way of obtaining an overview of vascular structures.

  12. Rapid differentiation of Listeria monocytogenes epidemic clones III and IV and their intact compared with heat-killed populations using Fourier transform infrared spectroscopy and chemometrics.

    PubMed

    Nyarko, Esmond B; Puzey, Kenneth A; Donnelly, Catherine W

    2014-06-01

    The objectives of this study were to determine if Fourier transform infrared (FT-IR) spectroscopy and multivariate statistical analysis (chemometrics) could be used to rapidly differentiate epidemic clones (ECs) of Listeria monocytogenes, as well as their intact compared with heat-killed populations. FT-IR spectra were collected from dried thin smears on infrared slides prepared from aliquots of 10 μL of each L. monocytogenes ECs (ECIII: J1-101 and R2-499; ECIV: J1-129 and J1-220), and also from intact and heat-killed cell populations of each EC strain using 250 scans at a resolution of 4 cm(-1) in the mid-infrared region in a reflectance mode. Chemometric analysis of spectra involved the application of the multivariate discriminant method for canonical variate analysis (CVA) and linear discriminant analysis (LDA). CVA of the spectra in the wavelength region 4000 to 600 cm(-1) separated the EC strains while LDA resulted in a 100% accurate classification of all spectra in the data set. Further, CVA separated intact and heat-killed cells of each EC strain and there was 100% accuracy in the classification of all spectra when LDA was applied. FT-IR spectral wavenumbers 1650 to 1390 cm(-1) were used to separate heat-killed and intact populations of L. monocytogenes. The FT-IR spectroscopy method allowed discrimination between strains that belong to the same EC. FT-IR is a highly discriminatory and reproducible method that can be used for the rapid subtyping of L. monocytogenes, as well as for the detection of live compared with dead populations of the organism. Fourier transform infrared (FT-IR) spectroscopy and multivariate statistical analysis can be used for L. monocytogenes source tracking and for clinical case isolate comparison during epidemiological investigations since the method is capable of differentiating epidemic clones and it uses a library of well-characterized strains. The FT-IR method is potentially less expensive and more rapid compared to genetic subtyping methods, and can be used for L. monocytogenes strain typing by food industries and public health agencies to enable faster response and intervention to listeriosis outbreaks. FT-IR can also be applied for routine monitoring of the pathogen in food processing plants and for investigating postprocessing contamination because it is capable of differentiating heat-killed and viable L. monocytogenes populations. © 2014 Institute of Food Technologists®

  13. Flight Test Results of a GPS-Based Pitot-Static Calibration Method Using Output-Error Optimization for a Light Twin-Engine Airplane

    NASA Technical Reports Server (NTRS)

    Martos, Borja; Kiszely, Paul; Foster, John V.

    2011-01-01

    As part of the NASA Aviation Safety Program (AvSP), a novel pitot-static calibration method was developed to allow rapid in-flight calibration for subscale aircraft while flying within confined test areas. This approach uses Global Positioning System (GPS) technology coupled with modern system identification methods that rapidly computes optimal pressure error models over a range of airspeed with defined confidence bounds. This method has been demonstrated in subscale flight tests and has shown small 2- error bounds with significant reduction in test time compared to other methods. The current research was motivated by the desire to further evaluate and develop this method for full-scale aircraft. A goal of this research was to develop an accurate calibration method that enables reductions in test equipment and flight time, thus reducing costs. The approach involved analysis of data acquisition requirements, development of efficient flight patterns, and analysis of pressure error models based on system identification methods. Flight tests were conducted at The University of Tennessee Space Institute (UTSI) utilizing an instrumented Piper Navajo research aircraft. In addition, the UTSI engineering flight simulator was used to investigate test maneuver requirements and handling qualities issues associated with this technique. This paper provides a summary of piloted simulation and flight test results that illustrates the performance and capabilities of the NASA calibration method. Discussion of maneuver requirements and data analysis methods is included as well as recommendations for piloting technique.

  14. Bioanalytical methods for food contaminant analysis.

    PubMed

    Van Emon, Jeanette M

    2010-01-01

    Foods are complex mixtures of lipids, carbohydrates, proteins, vitamins, organic compounds, and other naturally occurring substances. Sometimes added to this mixture are residues of pesticides, veterinary and human drugs, microbial toxins, preservatives, contaminants from food processing and packaging, and other residues. This milieu of compounds can pose difficulties in the analysis of food contaminants. There is an expanding need for rapid and cost-effective residue methods for difficult food matrixes to safeguard our food supply. Bioanalytical methods are established for many food contaminants such as mycotoxins and are the method of choice for many food allergens. Bioanalytical methods are often more cost-effective and sensitive than instrumental procedures. Recent developments in bioanalytical methods may provide more applications for their use in food analysis.

  15. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    PubMed

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  16. A Rapid Method of Genomic Array Analysis of Scaffold/Matrix Attachment Regions (S/MARs) Identifies a 2.5-Mb Region of Enhanced Scaffold/Matrix Attachment at a Human Neocentromere

    PubMed Central

    Sumer, Huseyin; Craig, Jeffrey M.; Sibson, Mandy; Choo, K.H. Andy

    2003-01-01

    Human neocentromeres are fully functional centromeres that arise at previously noncentromeric regions of the genome. We have tested a rapid procedure of genomic array analysis of chromosome scaffold/matrix attachment regions (S/MARs), involving the isolation of S/MAR DNA and hybridization of this DNA to a genomic BAC/PAC array. Using this procedure, we have defined a 2.5-Mb domain of S/MAR-enriched chromatin that fully encompasses a previously mapped centromere protein-A (CENP-A)-associated domain at a human neocentromere. We have independently verified this procedure using a previously established fluorescence in situ hybridization method on salt-treated metaphase chromosomes. In silico sequence analysis of the S/MAR-enriched and surrounding regions has revealed no outstanding sequence-related predisposition. This study defines the S/MAR-enriched domain of a higher eukaryotic centromere and provides a method that has broad application for the mapping of S/MAR attachment sites over large genomic regions or throughout a genome. PMID:12840048

  17. [Principle of LAMP method--a simple and rapid gene amplification method].

    PubMed

    Ushikubo, Hiroshi

    2004-06-01

    So far nucleic acid test (NAT) has been employed in various fields, including infectious disease diagnoses. However, due to its complicated procedures and relatively high cost, it has not been widely utilized in many actual diagnostic applications. We have therefore developed a simple and rapid gene amplification technology, Loop-mediated Isothermal Amplification (LAMP) method, which has shown prominent results of surpassing the performance of the conventional gene amplification methods. LAMP method acquires three main features: (1) all reaction can be carried out under isothermal conditions; (2) the amplification efficiency is extremely high and tremendous amount of amplification products can be obtained; and (3) the reaction is highly specific. Furthermore, developed from the standard LAMP method, a rapid LAMP method, by adding in the loop primers, can reduce the amplification time from the previous 1 hour to less than 30 minutes. Enormous amount of white precipitate of magnesium pyrophosphate is produced as a by-product of the amplification, therefore, direct visual detection is possible without using any reaction indicators and detection equipments. We believe LAMP technology, with the integration of these features, can rightly apply to clinical genetic testing, food and environmental analysis, as well as NAT in different fields.

  18. A semi-automated method for rapid detection of ripple events on interictal voltage discharges in the scalp electroencephalogram.

    PubMed

    Chu, Catherine J; Chan, Arthur; Song, Dan; Staley, Kevin J; Stufflebeam, Steven M; Kramer, Mark A

    2017-02-01

    High frequency oscillations are emerging as a clinically important indicator of epileptic networks. However, manual detection of these high frequency oscillations is difficult, time consuming, and subjective, especially in the scalp EEG, thus hindering further clinical exploration and application. Semi-automated detection methods augment manual detection by reducing inspection to a subset of time intervals. We propose a new method to detect high frequency oscillations that co-occur with interictal epileptiform discharges. The new method proceeds in two steps. The first step identifies candidate time intervals during which high frequency activity is increased. The second step computes a set of seven features for each candidate interval. These features require that the candidate event contain a high frequency oscillation approximately sinusoidal in shape, with at least three cycles, that co-occurs with a large amplitude discharge. Candidate events that satisfy these features are stored for validation through visual analysis. We evaluate the detector performance in simulation and on ten examples of scalp EEG data, and show that the proposed method successfully detects spike-ripple events, with high positive predictive value, low false positive rate, and high intra-rater reliability. The proposed method is less sensitive than the existing method of visual inspection, but much faster and much more reliable. Accurate and rapid detection of high frequency activity increases the clinical viability of this rhythmic biomarker of epilepsy. The proposed spike-ripple detector rapidly identifies candidate spike-ripple events, thus making clinical analysis of prolonged, multielectrode scalp EEG recordings tractable. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Rapid phenotypic antimicrobial susceptibility testing using nanoliter arrays.

    PubMed

    Avesar, Jonathan; Rosenfeld, Dekel; Truman-Rosentsvit, Marianna; Ben-Arye, Tom; Geffen, Yuval; Bercovici, Moran; Levenberg, Shulamit

    2017-07-18

    Antibiotic resistance is a major global health concern that requires action across all sectors of society. In particular, to allow conservative and effective use of antibiotics clinical settings require better diagnostic tools that provide rapid determination of antimicrobial susceptibility. We present a method for rapid and scalable antimicrobial susceptibility testing using stationary nanoliter droplet arrays that is capable of delivering results in approximately half the time of conventional methods, allowing its results to be used the same working day. In addition, we present an algorithm for automated data analysis and a multiplexing system promoting practicality and translatability for clinical settings. We test the efficacy of our approach on numerous clinical isolates and demonstrate a 2-d reduction in diagnostic time when testing bacteria isolated directly from urine samples.

  20. Rapid determination of actinides in seawater samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2014-03-09

    A new rapid method for the determination of actinides in seawater samples has been developed at the Savannah River National Laboratory. The actinides can be measured by alpha spectrometry or inductively-coupled plasma mass spectrometry. The new method employs novel pre-concentration steps to collect the actinide isotopes quickly from 80 L or more of seawater. Actinides are co-precipitated using an iron hydroxide co-precipitation step enhanced with Ti +3 reductant, followed by lanthanum fluoride co-precipitation. Stacked TEVA Resin and TRU Resin cartridges are used to rapidly separate Pu, U, and Np isotopes from seawater samples. TEVA Resin and DGA Resin were usedmore » to separate and measure Pu, Am and Cm isotopes in seawater volumes up to 80 L. This robust method is ideal for emergency seawater samples following a radiological incident. It can also be used, however, for the routine analysis of seawater samples for oceanographic studies to enhance efficiency and productivity. In contrast, many current methods to determine actinides in seawater can take 1–2 weeks and provide chemical yields of ~30–60 %. This new sample preparation method can be performed in 4–8 h with tracer yields of ~85–95 %. By employing a rapid, robust sample preparation method with high chemical yields, less seawater is needed to achieve lower or comparable detection limits for actinide isotopes with less time and effort.« less

  1. Flow cytomeric measurement of DNA and incorporated nucleoside analogs

    DOEpatents

    Dolbeare, Frank A.; Gray, Joe W.

    1989-01-01

    A method is provided for simultaneously measuring total cellular DNA and incorporated nucleoside analog. The method entails altering the cellular DNA of cells grown in the presence of a nucleoside analog so that single stranded and double stranded portions are present. Separate stains are used against the two portions. An immunochemical stain is used against the single stranded portion to provide a measure of incorporated nucleoside analog, and a double strand DNA-specific stain is used against the double stranded portion to simultaneously provide a measure of total cellular DNA. The method permits rapid flow cytometric analysis of cell populations, rapid identification of cycling and noncycling subpopulations, and determination of the efficacy of S phase cytotoxic anticancer agents.

  2. Energy dispersive X-ray fluorescence and scattering assessment of soil quality via partial least squares and artificial neural networks analytical modeling approaches.

    PubMed

    Kaniu, M I; Angeyo, K H; Mwala, A K; Mwangi, F K

    2012-08-30

    Soil quality assessment (SQA) calls for rapid, simple and affordable but accurate analysis of soil quality indicators (SQIs). Routine methods of soil analysis are tedious and expensive. Energy dispersive X-ray fluorescence and scattering (EDXRFS) spectrometry in conjunction with chemometrics is a potentially powerful method for rapid SQA. In this study, a 25 m Ci (109)Cd isotope source XRF spectrometer was used to realize EDXRFS spectrometry of soils. Glycerol (a simulate of "organic" soil solution) and kaolin (a model clay soil) doped with soil micro (Fe, Cu, Zn) and macro (NO(3)(-), SO(4)(2-), H(2)PO(4)(-)) nutrients were used to train multivariate chemometric calibration models for direct (non-invasive) analysis of SQIs based on partial least squares (PLS) and artificial neural networks (ANN). The techniques were compared for each SQI with respect to speed, robustness, correction ability for matrix effects, and resolution of spectral overlap. The method was then applied to perform direct rapid analysis of SQIs in field soils. A one-way ANOVA test showed no statistical difference at 95% confidence interval between PLS and ANN results compared to reference soil nutrients. PLS was more accurate analyzing C, N, Na, P and Zn (R(2)>0.9) and low SEP of (0.05%, 0.01%, 0.01%, and 1.98 μg g(-1)respectively), while ANN was better suited for analysis of Mg, Cu and Fe (R(2)>0.9 and SEP of 0.08%, 4.02 μg g(-1), and 0.88 μg g(-1) respectively). Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Rapid analysis of the skin irritant p-phenylenediamine (PPD) in henna products using atmospheric solids analysis probe mass spectrometry.

    PubMed

    Chen, Weiyang; Nkosi, Thobile A N; Combrinck, Sandra; Viljoen, Alvaro M; Cartwright-Jones, Catherine

    2016-09-05

    Henna (Lawsonia inermis) is applied to stain keratin, present in hair, skin and fingernails, a red-orange or rust colour. Producers of temporary tattoos mix the aromatic amine compound, para-phenylenediamine (PPD) into natural henna to create 'black henna' that rapidly stains the skin black. However, PPD may cause severe delayed hypersensitivity reactions following skin contact. This study proposes a rapid direct-analysis method to detect and identify PPD using an atmospheric solids analysis probe (ASAP) coupled to a Q-ToF mass spectrometer (MS). Since laborious, multistep methods of analysis to determine PPD are undesirable, due to the instability of the compound in solution, a screening method involving no sample preparation steps was developed. Experiments were carried out to optimise the corona current, sample cone voltage, source temperature, and desolvation gas temperature to determine ideal ASAP-Q-ToF-MS analysing conditions. Eleven of the 109 henna samples, originating from various countries, tested positive for PPD when henna products were screened using ASAP-MS, without any form of sample preparation other than grinding. Ultra-performance liquid chromatography electrospray ionisation-mass spectrometry (UPLC-Q-ToF-MS) was subsequently used to confirm the results from ASAP and to determine the concentrations of PPD in henna products. The allergen was detected in the same eleven samples, with concentrations ranging from 0.05-4.21% (w/w). It can be concluded that the sensitivity of the ASAP-MS technique is sufficient (limit of detection=0.025% w/w) to allow screening of henna samples for the presence of PPD. This relatively new technique can be applied to commercial products without extraction, sample treatment or chromatographic separation. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A method for rapid sampling and characterization of smokeless powder using sorbent-coated wire mesh and direct analysis in real time - mass spectrometry (DART-MS).

    PubMed

    Li, Frederick; Tice, Joseph; Musselman, Brian D; Hall, Adam B

    2016-09-01

    Improvised explosive devices (IEDs) are often used by terrorists and criminals to create public panic and destruction, necessitating rapid investigative information. However, backlogs in many forensic laboratories resulting in part from time-consuming GC-MS and LC-MS techniques prevent prompt analytical information. Direct analysis in real time - mass spectrometry (DART-MS) is a promising analytical technique that can address this challenge in the forensic science community by permitting rapid trace analysis of energetic materials. Therefore, we have designed a qualitative analytical approach that utilizes novel sorbent-coated wire mesh and dynamic headspace concentration to permit the generation of information rich chemical attribute signatures (CAS) for trace energetic materials in smokeless powder with DART-MS. Sorbent-coated wire mesh improves the overall efficiency of capturing trace energetic materials in comparison to swabbing or vacuuming. Hodgdon Lil' Gun smokeless powder was used to optimize the dynamic headspace parameters. This method was compared to traditional GC-MS methods and validated using the NIST RM 8107 smokeless powder reference standard. Additives and energetic materials, notably nitroglycerin, were rapidly and efficiently captured by the Carbopack X wire mesh, followed by detection and identification using DART-MS. This approach has demonstrated the capability of generating comparable results with significantly reduced analysis time in comparison to GC-MS. All targeted components that can be detected by GC-MS were detected by DART-MS in less than a minute. Furthermore, DART-MS offers the advantage of detecting targeted analytes that are not amenable to GC-MS. The speed and efficiency associated with both the sample collection technique and DART-MS demonstrate an attractive and viable potential alternative to conventional techniques. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Rapid-Viability PCR Method for Detection of Live, Virulent Bacillus anthracis in Environmental Samples ▿

    PubMed Central

    Létant, Sonia E.; Murphy, Gloria A.; Alfaro, Teneile M.; Avila, Julie R.; Kane, Staci R.; Raber, Ellen; Bunt, Thomas M.; Shah, Sanjiv R.

    2011-01-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples. PMID:21764960

  6. Rapid Analysis of Inorganic Species in Herbaceous Materials Using Laser-Induced Breakdown Spectroscopy

    PubMed Central

    Emerson, Rachel M.

    2015-01-01

    Abstract Inorganic compounds in biomass, often referred to as ash, are known to be problematic in the thermochemical conversion of biomass to bio-oil or syngas and, ultimately, hydrocarbon fuels because they negatively influence reaction pathways, contribute to fouling and corrosion, poison catalysts, and impact waste streams. The most common ash-analysis methods, such as inductively coupled plasma-optical emission spectrometry/mass spectrometry (ICP-OES/MS), require considerable time and expensive reagents. Laser-induced breakdown spectroscopy (LIBS) is emerging as a technique for rapid analysis of the inorganic constituents in a wide range of biomass materials. This study compares analytical results using LIBS data to results obtained from three separate ICP-OES/MS methods for 12 samples, including six standard reference materials. Analyzed elements include aluminum, calcium, iron, magnesium, manganese, phosphorus, potassium, sodium, and silicon, and results show that concentrations can be measured with an uncertainty of approximately 100 parts per million using univariate calibration models and relatively few calibration samples. These results indicate that the accuracy of LIBS is comparable to that of ICP-OES methods and indicate that some acid-digestion methods for ICP-OES may not be reliable for Na and Al. These results also demonstrate that germanium can be used as an internal standard to improve the reliability and accuracy of measuring many elements of interest, and that LIBS can be used for rapid determination of total ash in biomass samples. Key benefits of LIBS include little sample preparation, no reagent consumption, and the generation of meaningful analytical data instantaneously. PMID:26733765

  7. Rapid detection of methanol in artisanal alcoholic beverages

    NASA Astrophysics Data System (ADS)

    de Goes, R. E.; Muller, M.; Fabris, J. L.

    2015-09-01

    In the industry of artisanal beverages, uncontrolled production processes may result in contaminated products with methanol, leading to risks for consumers. Owing to the similar odor of methanol and ethanol, as well as their common transparency, the distinction between them is a difficult task. Contamination may also occur deliberately due to the lower price of methanol when compared to ethanol. This paper describes a spectroscopic method for methanol detection in beverages based on Raman scattering and Principal Component Analysis. Associated with a refractometric assessment of the alcohol content, the method may be applied in field for a rapid detection of methanol presence.

  8. Rapid Quantitative Determination of Squalene in Shark Liver Oils by Raman and IR Spectroscopy.

    PubMed

    Hall, David W; Marshall, Susan N; Gordon, Keith C; Killeen, Daniel P

    2016-01-01

    Squalene is sourced predominantly from shark liver oils and to a lesser extent from plants such as olives. It is used for the production of surfactants, dyes, sunscreen, and cosmetics. The economic value of shark liver oil is directly related to the squalene content, which in turn is highly variable and species-dependent. Presented here is a validated gas chromatography-mass spectrometry analysis method for the quantitation of squalene in shark liver oils, with an accuracy of 99.0 %, precision of 0.23 % (standard deviation), and linearity of >0.999. The method has been used to measure the squalene concentration of 16 commercial shark liver oils. These reference squalene concentrations were related to infrared (IR) and Raman spectra of the same oils using partial least squares regression. The resultant models were suitable for the rapid quantitation of squalene in shark liver oils, with cross-validation r (2) values of >0.98 and root mean square errors of validation of ≤4.3 % w/w. Independent test set validation of these models found mean absolute deviations of the 4.9 and 1.0 % w/w for the IR and Raman models, respectively. Both techniques were more accurate than results obtained by an industrial refractive index analysis method, which is used for rapid, cheap quantitation of squalene in shark liver oils. In particular, the Raman partial least squares regression was suited to quantitative squalene analysis. The intense and highly characteristic Raman bands of squalene made quantitative analysis possible irrespective of the lipid matrix.

  9. Triacylglycerol "hand-shape profile" of Argan oil. Rapid and simple UHPLC-PDA-ESI-TOF/MS and HPTLC methods to detect counterfeit Argan oil and Argan-oil-based products.

    PubMed

    Pagliuca, Giordana; Bozzi, Carlotta; Gallo, Francesca Romana; Multari, Giuseppina; Palazzino, Giovanna; Porrà, Rita; Panusa, Alessia

    2018-02-20

    The marketing of new argan-based products is greatly increased in the last few years and consequently, it has enhanced the number of control analysis aimed at detecting counterfeit products claiming argan oil as a major ingredient. Argan oil is produced in Morocco and it is quite expensive. Two simple methods for the rapid screening of pure oil and argan-oil based products, focused on the analysis of the triacylglycerol profile, have been developed. A three-minute-run by UHPLC-PDA allows the identification of a pure argan oil, while the same run with the MS detector allows also the analysis of products containing the oil down to 0.03%. On the other hand, by HPTLC the simultaneous analysis of twenty samples, containing argan oil down to 0.5%, can be carried out in a forty-five-minute run. The triglyceride profile of the most common vegetable fats such as almond, coconut, linseed, wheat germ, sunflower, peanut, olive, soybean, rapeseed, hemp oils as well as shea butter used either in cosmetics or commonly added for the counterfeiting of argan oil, has been also investigated. Over sixty products with different formulations and use have been successfully analyzed and argan oil in the 2.4-0.06% concentration range has been quantified. The methods are suitable either for a rapid screening or for quantifying argan oil in different formulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Rapid analysis of aminoglycoside antibiotics in bovine tissues using disposable pipette extraction and ultrahigh performance liquid chromatography - tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    A high-throughput qualitative screening and identification method for 9 aminoglycosides of regulatory interest has been developed, validated, and implemented for bovine kidney, liver, and muscle tissues. The method involves extraction at previously validated conditions, cleanup using disposable pip...

  11. New Method for Analysis of Multiple Anthelmintic Residues in Animal Tissue

    USDA-ARS?s Scientific Manuscript database

    For the first time, 39 of the major anthelmintics can be detected in one rapid and sensitive LC-MS/MS method, including the flukicides, which have been generally overlooked in surveillance programs. Utilizing the QuEChERS approach, residues were extracted from liver and milk using acetonitrile, sod...

  12. Acid Rain Analysis by Standard Addition Titration.

    ERIC Educational Resources Information Center

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  13. Rapid deletion plasmid construction methods for protoplast and Agrobacterium based fungal transformation systems

    USDA-ARS?s Scientific Manuscript database

    Increasing availability of genomic data and sophistication of analytical methodology in fungi has elevated the need for functional genomics tools in these organisms. Gene deletion is a critical tool for functional analysis. The targeted deletion of genes requires both a suitable method for the trans...

  14. Rapid Detection Method for the Four Most Common CHEK2 Mutations Based on Melting Profile Analysis.

    PubMed

    Borun, Pawel; Salanowski, Kacper; Godlewski, Dariusz; Walkowiak, Jaroslaw; Plawski, Andrzej

    2015-12-01

    CHEK2 is a tumor suppressor gene, and the mutations affecting the functionality of the protein product increase cancer risk in various organs. The elevated risk, in a significant percentage of cases, is determined by the occurrence of one of the four most common mutations in the CHEK2 gene, including c.470T>C (p.I157T), c.444+1G>A (IVS2+1G>A), c.1100delC, and c.1037+1538_1224+328del5395 (del5395). We have developed and validated a rapid and effective method for their detection based on high-resolution melting analysis and comparative-high-resolution melting, a novel approach enabling simultaneous detection of copy number variations. The analysis is performed in two polymerase chain reactions followed by melting analysis, without any additional reagents or handling other than that used in standard high-resolution melting. Validation of the method was conducted in a group of 103 patients with diagnosed breast cancer, a group of 240 unrelated patients with familial history of cancer associated with the CHEK2 gene mutations, and a 100-person control group. The results of the analyses for all three groups were fully consistent with the results from other methods. The method we have developed improves the identification of the CHEK2 mutation carriers, reduces the cost of such analyses, as well as facilitates their implementation. Along with the increased efficiency, the method maintains accuracy and reliability comparable to other more labor-consuming techniques.

  15. Development of high through-put Sr isotope analysis for monitoring reservoir integrity for CO{sub 2} storage.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wall, Andy; Jain, Jinesh; Stewart, Brian

    2012-01-01

    Recent innovations in multi-collector ICP-mass spectrometry (MC-ICP-MS) have allowed for rapid and precise measurements of isotope ratios in geological samples. Naturally occurring Sr isotopes has the potential for use in Monitoring, Verification, and Accounting (MVA) associated with geologic CO2 storage. Sr isotopes can be useful for: Sensitive tracking of brine migration; Determining seal rock leakage; Studying fluid/rock reactions. We have optimized separation chemistry procedures that will allow operators to prepare samples for Sr isotope analysis off site using rapid, low cost methods.

  16. Headspace analysis of polar organic compounds in biological matrixes using solid phase microextraction (SPME)

    USDA-ARS?s Scientific Manuscript database

    Analysis of biological fluids and waste material is difficult and tedious given the sample matrix. A rapid automated method for the determination of volatile fatty acids and phenolic and indole compounds was developed using a multipurpose sampler (MPS) with solid phase microextraction (SPME) and GC-...

  17. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  18. Analysis of ecologically relevant pharmaceuticals in wastewater and surface water using selective solid phase extraction and UPLC/MS/MS

    EPA Science Inventory

    A rapid and sensitive method has been developed for the analysis of 48 human prescription active pharmaceutical ingredients (APIs) and 6 metabolites of interest, utilizing selective solid-phase extraction (SPE) and ultra performance liquid chromatography in combination with tripl...

  19. Rapid quality assessment of Radix Aconiti Preparata using direct analysis in real time mass spectrometry.

    PubMed

    Zhu, Hongbin; Wang, Chunyan; Qi, Yao; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2012-11-08

    This study presents a novel and rapid method to identify chemical markers for the quality control of Radix Aconiti Preparata, a world widely used traditional herbal medicine. In the method, the samples with a fast extraction procedure were analyzed using direct analysis in real time mass spectrometry (DART MS) combined with multivariate data analysis. At present, the quality assessment approach of Radix Aconiti Preparata was based on the two processing methods recorded in Chinese Pharmacopoeia for the purpose of reducing the toxicity of Radix Aconiti and ensuring its clinical therapeutic efficacy. In order to ensure the safety and effectivity in clinical use, the processing degree of Radix Aconiti should be well controlled and assessed. In the paper, hierarchical cluster analysis and principal component analysis were performed to evaluate the DART MS data of Radix Aconiti Preparata samples in different processing times. The results showed that the well processed Radix Aconiti Preparata, unqualified processed and the raw Radix Aconiti could be clustered reasonably corresponding to their constituents. The loading plot shows that the main chemical markers having the most influence on the discrimination amongst the qualified and unqualified samples were mainly some monoester diterpenoid aconitines and diester diterpenoid aconitines, i.e. benzoylmesaconine, hypaconitine, mesaconitine, neoline, benzoylhypaconine, benzoylaconine, fuziline, aconitine and 10-OH-mesaconitine. The established DART MS approach in combination with multivariate data analysis provides a very flexible and reliable method for quality assessment of toxic herbal medicine. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Malaria surveillance in the Democratic Republic of the Congo: comparison of microscopy, PCR, and rapid diagnostic test.

    PubMed

    Doctor, Stephanie M; Liu, Yunhao; Whitesell, Amy; Thwai, Kyaw L; Taylor, Steve M; Janko, Mark; Emch, Michael; Kashamuka, Melchior; Muwonga, Jérémie; Tshefu, Antoinette; Meshnick, Steven R

    2016-05-01

    Malaria surveillance is critical for control efforts, but diagnostic methods frequently disagree. Here, we compare microscopy, PCR, and a rapid diagnostic test in 7137 samples from children in the Democratic Republic of the Congo using latent class analysis. PCR had the highest sensitivity (94.6%) and microscopy had the lowest (76.7%). Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Analysis of Preconditioning and Relaxation Operators for the Discontinuous Galerkin Method Applied to Diffusion

    NASA Technical Reports Server (NTRS)

    Atkins, H. L.; Shu, Chi-Wang

    2001-01-01

    The explicit stability constraint of the discontinuous Galerkin method applied to the diffusion operator decreases dramatically as the order of the method is increased. Block Jacobi and block Gauss-Seidel preconditioner operators are examined for their effectiveness at accelerating convergence. A Fourier analysis for methods of order 2 through 6 reveals that both preconditioner operators bound the eigenvalues of the discrete spatial operator. Additionally, in one dimension, the eigenvalues are grouped into two or three regions that are invariant with order of the method. Local relaxation methods are constructed that rapidly damp high frequencies for arbitrarily large time step.

  2. A rapid and sensitive method for the simultaneous analysis of aliphatic and polar molecules containing free carboxyl groups in plant extracts by LC-MS/MS

    PubMed Central

    2009-01-01

    Background Aliphatic molecules containing free carboxyl groups are important intermediates in many metabolic and signalling reactions, however, they accumulate to low levels in tissues and are not efficiently ionized by electrospray ionization (ESI) compared to more polar substances. Quantification of aliphatic molecules becomes therefore difficult when small amounts of tissue are available for analysis. Traditional methods for analysis of these molecules require purification or enrichment steps, which are onerous when multiple samples need to be analyzed. In contrast to aliphatic molecules, more polar substances containing free carboxyl groups such as some phytohormones are efficiently ionized by ESI and suitable for analysis by LC-MS/MS. Thus, the development of a method with which aliphatic and polar molecules -which their unmodified forms differ dramatically in their efficiencies of ionization by ESI- can be simultaneously detected with similar sensitivities would substantially simplify the analysis of complex biological matrices. Results A simple, rapid, specific and sensitive method for the simultaneous detection and quantification of free aliphatic molecules (e.g., free fatty acids (FFA)) and small polar molecules (e.g., jasmonic acid (JA), salicylic acid (SA)) containing free carboxyl groups by direct derivatization of leaf extracts with Picolinyl reagent followed by LC-MS/MS analysis is presented. The presence of the N atom in the esterified pyridine moiety allowed the efficient ionization of 25 compounds tested irrespective of their chemical structure. The method was validated by comparing the results obtained after analysis of Nicotiana attenuata leaf material with previously described analytical methods. Conclusion The method presented was used to detect 16 compounds in leaf extracts of N. attenuata plants. Importantly, the method can be adapted based on the specific analytes of interest with the only consideration that the molecules must contain at least one free carboxyl group. PMID:19939243

  3. Rapid Detection & Identification of Bacillus Species using MALDI-TOF/TOF and Biomarker Database

    DTIC Science & Technology

    2006-06-01

    rRNA sequence analysis. Multilocus enzyme electrophoresis ( MEE ) and comparative DNA sequence analysis suggest that they may represent a single species...adaptation of the MEE method [63] but with greater discrimination [64]. All of these new PCR-based subtyping methods are certainly superior and more...Demirev, P.A., Lin, J.S., Pineda , F.J., and Fenselau, C. (2001). Bioinformatics and mass spectrometry for microorganism identification: proteome-wide

  4. Improving Student Understanding of Qualitative and Quantitative Analysis via GC/MS Using a Rapid SPME-Based Method for Determination of Trihalomethanes in Drinking Water

    ERIC Educational Resources Information Center

    Huang, Shu Rong; Palmer, Peter T.

    2017-01-01

    This paper describes a method for determination of trihalomethanes (THMs) in drinking water via solid-phase microextraction (SPME) GC/MS as a means to develop and improve student understanding of the use of GC/MS for qualitative and quantitative analysis. In the classroom, students are introduced to SPME, GC/MS instrumentation, and the use of MS…

  5. A Rapid and Efficient Method for Evaluation of Suspect Testimony: Palynological Scanning.

    PubMed

    Wiltshire, Patricia E J; Hawksworth, David L; Edwards, Kevin J

    2015-11-01

    A rapid method for evaluating suspect testimony is valuable at any stage in an inquiry and can result in a change of direction in an investigation. Rape cases, in particular, can present problems where a defendant renders DNA analysis redundant by claiming that the claimant consented to have sexual relations. Forensic palynology is valuable in confirming or eliminating locations as being crime scenes, thus checking the testimony of both parties. In contrast to some forensic disciplines, forensic palynology can provide critical information without time-consuming full analysis. Two cases are described where the palynological assemblages from comparator samples of pertinent places were compared with those obtained from clothing of claimants and defendants. The results of rapid microscopical scanning of relevant preparations led to early confessions, thus obviating the need for costly analyses and protracted court proceedings. A third case demonstrates the unbiased nature of this technique where a man, although innocent of any offense, lied about having visited the crime scene for fear of prosecution. This highlights the need for sensitive policing in claims of rape. © 2015 American Academy of Forensic Sciences.

  6. Rapid protein concentration, efficient fluorescence labeling and purification on a micro/nanofluidics chip.

    PubMed

    Wang, Chen; Ouyang, Jun; Ye, De-Kai; Xu, Jing-Juan; Chen, Hong-Yuan; Xia, Xing-Hua

    2012-08-07

    Fluorescence analysis has proved to be a powerful detection technique for achieving single molecule analysis. However, it usually requires the labeling of targets with bright fluorescent tags since most chemicals and biomolecules lack fluorescence. Conventional fluorescence labeling methods require a considerable quantity of biomolecule samples, long reaction times and extensive chromatographic purification procedures. Herein, a micro/nanofluidics device integrating a nanochannel in a microfluidics chip has been designed and fabricated, which achieves rapid protein concentration, fluorescence labeling, and efficient purification of product in a miniaturized and continuous manner. As a demonstration, labeling of the proteins bovine serum albumin (BSA) and IgG with fluorescein isothiocyanate (FITC) is presented. Compared to conventional methods, the present micro/nanofluidics device performs about 10(4)-10(6) times faster BSA labeling with 1.6 times higher yields due to the efficient nanoconfinement effect, improved mass, and heat transfer in the chip device. The results demonstrate that the present micro/nanofluidics device promises rapid and facile fluorescence labeling of small amount of reagents such as proteins, nucleic acids and other biomolecules with high efficiency.

  7. A method for the rapid detection of urinary tract infections.

    PubMed

    Olsson, Carl; Kapoor, Deepak; Howard, Glenn

    2012-04-01

    To determine the reliability of a rapid detection method compared with the reference standard streaked agar plate in diagnosing the presence of urinary tract infection (UTI). De-identified clean catch urine specimens from 980 office visit patients were processed during a 30-day period. Classic 1-μL and 10-μL streaked agar plates were used in parallel with the new CultureStat Rapid UTI Detection System (CSRUDS). Urine results were evaluated using the CSRUDS at 30 and 90 minutes after collection. A comparative analysis of the subsequent plate results versus the CSRUDS results was achieved for 973 of these samples. Positive UTI conditions were accurately identified by both CSRUDS and agar streak plate methods. CSRUDS accurately identified UTI negative conditions with 99.3% reliability at 90 minutes. The negative predictive value of CSRUDS was 99.2% at 30 minutes. Current agar plating for first-round UTI screening has substantial documented problems that can negatively affect an accurate and timely UTI diagnosis. A novel rapid detection system, the CSRUDS provides UTI negative/positive same-day results in ≤ 90 minutes from the start of test. Such rapidly available results will enable more accurate and timely clinical decisions to be made in the urology office, particularly regarding infection status before urologic instrumentation. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Rapid and interference-free analysis of nine B-group vitamins in energy drinks using trilinear component modeling of liquid chromatography-mass spectrometry data.

    PubMed

    Hu, Yong; Wu, Hai-Long; Yin, Xiao-Li; Gu, Hui-Wen; Xiao, Rong; Xie, Li-Xia; Liu, Zhi; Fang, Huan; Wang, Li; Yu, Ru-Qin

    2018-04-01

    The aim of the present work was to develop a rapid and interference-free method based on liquid chromatography-mass spectrometry (LC-MS) for the simultaneous determination of nine B-group vitamins in various energy drinks. A smart and green strategy that modeled the three-way data array of LC-MS with second-order calibration methods based on alternating trilinear decomposition (ATLD) and alternating penalty trilinear decomposition (APTLD) algorithms was developed. By virtue of "mathematical separation" and "second-order advantage", the proposed strategy successfully solved the co-eluted peaks and unknown interferents in LC-MS analysis with the elution time less than 4.5min and simple sample preparation. Satisfactory quantitative results were obtained by the ATLD-LC-MS and APTLD-LC-MS methods for the spiked recovery assays, with the average spiked recoveries ranging from 87.2-113.9% to 92.0-111.7%, respectively. These results acquired from the proposed methods were confirmed by the LC-MS/MS method, which shows a quite good consistency with each other. All these results demonstrated that the developed chemometrics-assisted LC-MS strategy had advantages of being rapid, green, accurate and low-cost, and it could be an attractive alternative for the determination of multiple vitamins in complex food matrices, which required no laborious sample preparation, tedious condition optimization or more sophisticated instrumentations. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Role of Clinical Presentations and Routine CSF Analysis in the Rapid Diagnosis of Acute Bacterial Meningitis in Cases of Negative Gram Stained Smears

    PubMed Central

    Fouad, Rabab; El-Kholy, Badawy; Yosry, Ayman

    2014-01-01

    Background and Aim. Bacterial meningitis is a lethal, disabling endemic disease needing prompt antibiotic management. Gram stained smears is rapid accurate method for diagnosis of bacterial meningitis. In cases of negative gram stained smears diagnosis is delayed till culture results. We aim to assess the role of clinical presentations and routine CSF analysis in the cost-effective rapid diagnosis of negative gram stained smears bacterial meningitis. Methods. Cross sectional study including 623 acute meningitis patients divided into two groups: bacterial meningitis and nonbacterial meningitis groups. The clinical presentations, systemic inflammatory parameters, and CSF analysis were evaluated and compared in both groups. Results. Altered conscious level, localizing neurological signs, Kernig's and Brudzinski's signs together with peripheral leucocytosis (>10.000/mm3), high CRP (>6) together with high CSF protein (>50 gl/dL), CSF neutrophilic count (≥50% of total CSF leucocytic count), and low CSF glucose level (<45 gm/dL) and CSF/serum glucose ≤0.6 were significantly diagnostic in bacterial meningitis patients. From the significant CSF analysis variables CSF protein carried the higher accuracy of diagnosis 78% with sensitivity 88% and specificity 72%. Conclusions. High CSF protein (>50 mg/dL) together with plasma inflammatory markers and CSF cytochemical parameters can diagnose bacterial meningitis in gram stain negative smear till culture results. PMID:24803939

  10. Improved ultra-performance liquid chromatography with electrospray ionization quadrupole-time-of-flight high-definition mass spectrometry method for the rapid analysis of the chemical constituents of a typical medical formula: Liuwei Dihuang Wan.

    PubMed

    Wang, Ping; Lv, Hai tao; Zhang, Ai hua; Sun, Hui; Yan, Guang li; Han, Ying; Wu, Xiu hong; Wang, Xi jun

    2013-11-01

    Liuwei Dihuang Wan (LDW), a classic Chinese medicinal formula, has been used to improve or restore declined functions related to aging and geriatric diseases, such as impaired mobility, vision, hearing, cognition, and memory. It has attracted increasing attention as one of the most popular and valuable herbal medicines. However, the systematic analysis of the chemical constituents of LDW is difficult and thus has not been well established. In this paper, a rapid, sensitive, and reliable ultra-performance LC with ESI quadrupole TOF high-definition MS method with automated MetaboLynx analysis in positive and negative ion mode was established to characterize the chemical constituents of LDW. The analysis was performed on a Waters UPLC™ HSS T3 using a gradient elution system. MS/MS fragmentation behavior was proposed for aiding the structural identification of the components. Under the optimized conditions, a total of 50 peaks were tentatively characterized by comparing the retention time and MS data. It is concluded that a rapid and robust platform based on ultra-performance LC with ESI quadrupole TOF high-definition MS has been successfully developed for globally identifying multiple constituents of traditional Chinese medicine prescriptions. This is the first report on the systematic analysis of the chemical constituents of LDW. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Lessons learned from implementing a wet laboratory molecular training workshop for beach water quality monitoring.

    PubMed

    Verhougstraete, Marc Paul; Brothers, Sydney; Litaker, Wayne; Blackwood, A Denene; Noble, Rachel

    2015-01-01

    Rapid molecular testing methods are poised to replace many of the conventional, culture-based tests currently used in fields such as water quality and food science. Rapid qPCR methods have the benefit of being faster than conventional methods and provide a means to more accurately protect public health. However, many scientists and technicians in water and food quality microbiology laboratories have limited experience using these molecular tests. To ensure that practitioners can use and implement qPCR techniques successfully, we developed a week long workshop to provide hands-on training and exposure to rapid molecular methods for water quality management. This workshop trained academic professors, government employees, private industry representatives, and graduate students in rapid qPCR methods for monitoring recreational water quality. Attendees were immersed in these new methods with hands-on laboratory sessions, lectures, and one-on-one training. Upon completion, the attendees gained sufficient knowledge and practice to teach and share these new molecular techniques with colleagues at their respective laboratories. Key findings from this workshop demonstrated: 1) participants with no prior experience could be effectively trained to conduct highly repeatable qPCR analysis in one week; 2) participants with different desirable outcomes required exposure to a range of different platforms and sample processing approaches; and 3) the collaborative interaction amongst newly trained practitioners, workshop leaders, and members of the water quality community helped foster a cohesive cohort of individuals which can advocate powerful cohort for proper implementation of molecular methods.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    A new rapid fusion method for the determination of plutonium in large rice samples has been developed at the Savannah River National Laboratory (Aiken, SC, USA) that can be used to determine very low levels of plutonium isotopes in rice. The recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid, reliable radiochemical analyses for radionuclides in environmental and food samples. Public concern regarding foods, particularly foods such as rice in Japan, highlights the need for analytical techniques that will allow very large sample aliquots of rice to be used for analysis so thatmore » very low levels of plutonium isotopes may be detected. The new method to determine plutonium isotopes in large rice samples utilizes a furnace ashing step, a rapid sodium hydroxide fusion method, a lanthanum fluoride matrix removal step, and a column separation process with TEVA Resin cartridges. The method can be applied to rice sample aliquots as large as 5 kg. Plutonium isotopes can be determined using alpha spectrometry or inductively-coupled plasma mass spectrometry (ICP-MS). The method showed high chemical recoveries and effective removal of interferences. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory plutonium particles are effectively digested. The MDA for a 5 kg rice sample using alpha spectrometry is 7E-5 mBq g{sup -1}. The method can easily be adapted for use by ICP-MS to allow detection of plutonium isotopic ratios.« less

  13. Lessons Learned from Implementing a Wet Laboratory Molecular Training Workshop for Beach Water Quality Monitoring

    PubMed Central

    Verhougstraete, Marc Paul; Brothers, Sydney; Litaker, Wayne; Blackwood, A. Denene; Noble, Rachel

    2015-01-01

    Rapid molecular testing methods are poised to replace many of the conventional, culture-based tests currently used in fields such as water quality and food science. Rapid qPCR methods have the benefit of being faster than conventional methods and provide a means to more accurately protect public health. However, many scientists and technicians in water and food quality microbiology laboratories have limited experience using these molecular tests. To ensure that practitioners can use and implement qPCR techniques successfully, we developed a week long workshop to provide hands-on training and exposure to rapid molecular methods for water quality management. This workshop trained academic professors, government employees, private industry representatives, and graduate students in rapid qPCR methods for monitoring recreational water quality. Attendees were immersed in these new methods with hands-on laboratory sessions, lectures, and one-on-one training. Upon completion, the attendees gained sufficient knowledge and practice to teach and share these new molecular techniques with colleagues at their respective laboratories. Key findings from this workshop demonstrated: 1) participants with no prior experience could be effectively trained to conduct highly repeatable qPCR analysis in one week; 2) participants with different desirable outcomes required exposure to a range of different platforms and sample processing approaches; and 3) the collaborative interaction amongst newly trained practitioners, workshop leaders, and members of the water quality community helped foster a cohesive cohort of individuals which can advocate powerful cohort for proper implementation of molecular methods. PMID:25822486

  14. Rapid analysis of pharmaceuticals and personal care products in fish plasma micro-aliquots using liquid chromatography tandem mass spectrometry.

    PubMed

    Chen, Fangfang; Gong, Zhiyuan; Kelly, Barry C

    2015-02-27

    A sensitive analytical method based on liquid-liquid extraction (LLE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed for rapid analysis of 11 pharmaceuticals and personal care products (PPCPs) in fish plasma micro-aliquots (∼20μL). Target PPCPs included, bisphenol A, carbamazepine, diclofenac, fluoxetine, gemfibrozil, ibuprofen, naproxen, risperidone, sertraline, simvastatin and triclosan. A relatively quicker and cheaper LLE procedure exhibited comparable analyte recoveries with solid-phase extraction. Rapid separation and analysis of target compounds in fish plasma extracts was achieved by employing a high efficiency C-18 HPLC column (Agilent Poroshell 120 SB-C18, 2.1mm×50mm, 2.7μm) and fast polarity switching, enabling effective monitoring of positive and negative ions in a single 9min run. With the exception of bisphenol A, which exhibited relatively high background contamination, method detection limits of individual PPCPs ranged between 0.15 and 0.69pg/μL, while method quantification limits were between 0.05 and 2.3pg/μL. Mean matrix effect (ME) values ranged between 65 and 156% for the various target analytes. Isotope dilution quantification using isotopically labelled internal surrogates was utilized to correct for signal suppression or enhancement and analyte losses during sample preparation. The method was evaluated by analysis of 20μL plasma micro-aliquots collected from zebrafish (Danio rerio) from a laboratory bioaccumulation study, which included control group fish (no exposure), as well as fish exposed to environmentally relevant concentrations of PPCPs. Using the developed LC-MS/MS based method, concentrations of the studied PPCPs were consistently detected in the low pg/μL (ppb) range. The method may be useful for investigations requiring fast, reliable concentration measurements of PPCPs in fish plasma. In particular, the method may be applicable for in situ contaminant biomonitoring, as well as bioaccumulation and toxicology studies employing small fishes with low blood compartment volumes. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Analysis of select Dalbergia and trade timber using direct analysis in real time and time-of-flight mass spectrometry for CITES enforcement.

    PubMed

    Lancaster, Cady; Espinoza, Edgard

    2012-05-15

    International trade of several Dalbergia wood species is regulated by The Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES). In order to supplement morphological identification of these species, a rapid chemical method of analysis was developed. Using Direct Analysis in Real Time (DART) ionization coupled with Time-of-Flight (TOF) Mass Spectrometry (MS), selected Dalbergia and common trade species were analyzed. Each of the 13 wood species was classified using principal component analysis and linear discriminant analysis (LDA). These statistical data clusters served as reliable anchors for species identification of unknowns. Analysis of 20 or more samples from the 13 species studied in this research indicates that the DART-TOFMS results are reproducible. Statistical analysis of the most abundant ions gave good classifications that were useful for identifying unknown wood samples. DART-TOFMS and LDA analysis of 13 species of selected timber samples and the statistical classification allowed for the correct assignment of unknown wood samples. This method is rapid and can be useful when anatomical identification is difficult but needed in order to support CITES enforcement. Published 2012. This article is a US Government work and is in the public domain in the USA.

  16. Analysis of beta-lactam antibiotics in incurred raw milk by rapid test methods and liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Riediker, S; Diserens, J M; Stadler, R H

    2001-09-01

    A recently developed confirmatory LC-MS method has been applied to the quantification of five major beta-lactam antibiotics in suspect raw bovine milk samples that gave a positive response with receptor-based (BetaStar) and rapid microbial inhibitory screen tests (Delvotest SP). In total, 18 presumptive positive raw milk samples were reanalyzed; 16 samples showed traces of antibiotic residues that could be identified and quantified by the LC-MS method, ranging from the limits of confirmation up to 38 microg/kg. Of the positive samples, only five (approximately 30%) were found to be violative of EU maximum residue limits. The most frequently detected antibiotic residues were cloxacillin and penicillin G, the former often in combination with amoxicillin or ampicillin. This study compares the results obtained by the three methods on identical samples and addresses how these relate to certain criteria such as sensitivity and selectivity. Furthermore, the limitations of the LC-MS method and the potential impact of the presence of frequently more than one residue in the same milk sample on the response of the rapid test methods are discussed.

  17. Check-All-That-Apply (CATA), Sorting, and Polarized Sensory Positioning (PSP) with Astringent Stimuli

    PubMed Central

    Fleming, Erin E.; Ziegler, Gregory R.; Hayes, John E.

    2015-01-01

    Multiple rapid sensory profiling techniques have been developed as more efficient alternatives to traditional sensory descriptive analysis. Here, we compare the results of three rapid sensory profiling techniques – check-all-that-apply (CATA), sorting, and polarized sensory positioning (PSP) – using a diverse range of astringent stimuli. These rapid methods differ in their theoretical basis, implementation, and data analyses, and the relative advantages and limitations are largely unexplored. Additionally, we were interested in using these methods to compare varied astringent stimuli, as these compounds are difficult to characterize using traditional descriptive analysis due to high fatigue and potential carry-over. In the CATA experiment, subjects (n=41) were asked to rate the overall intensity of each stimulus as well as to endorse any relevant terms (from a list of 13) which characterized the sample. In the sorting experiment, subjects (n=30) assigned intensity-matched stimuli into groups 1-on-1 with the experimenter. In the PSP experiment, (n=41) subjects first sampled and took notes on three blind references (‘poles’) before rating each stimulus for its similarity to each of the 3 poles. Two-dimensional perceptual maps from correspondence analysis (CATA), multidimensional scaling (sorting), and multiple factor analysis (PSP) were remarkably similar, with normalized RV coefficients indicating significantly similar plots, regardless of method. Agglomerative hierarchical clustering of all data sets using Ward’s minimum variance as the linkage criteria showed the clusters of astringent stimuli were approximately based on the respective class of astringent agent. Based on the descriptive CATA data, it appears these differences may be due to the presence of side tastes such as bitterness and sourness, rather than astringent sub-qualities per se. Although all three methods are considered ‘rapid,’ our prior experience with sorting suggests it is best performed 1:1 with the experimenter, which makes sorting relatively less efficient than CATA or PSP. Based on the evaluation criteria used here, the choice of method depends on the time constraints of the experimenter and the need for descriptive terms to understand the sensory space of the samples. Accordingly, we recommend a mixed approach that combines CATA with a subsequent PSP task so that the product space can be well characterized before choosing poles for PSP. PMID:26113771

  18. Gold nanoparticle-sensitized quartz crystal microbalance sensor for rapid and highly selective determination of Cu(II) ions.

    PubMed

    Jin, Yulong; Huang, Yanyan; Liu, Guoquan; Zhao, Rui

    2013-09-21

    A novel quartz crystal microbalance (QCM) sensor for rapid, highly selective and sensitive detection of copper ions was developed. As a signal amplifier, gold nanoparticles (Au NPs) were self-assembled onto the surface of the sensor. A simple dip-and-dry method enabled the whole detection procedure to be accomplished within 20 min. High selectivity of the sensor towards copper ions is demonstrated by both individual and coexisting assays with interference ions. This gold nanoparticle mediated amplification allowed a detection limit down to 3.1 μM. Together with good repeatability and regeneration, the QCM sensor was also applied to the analysis of copper contamination in drinking water. This work provides a flexible method for fabricating QCM sensors for the analysis of important small molecules in environmental and biological samples.

  19. Mass Spectrometry Analysis of Spatial Protein Networks by Colocalization Analysis (COLA).

    PubMed

    Mardakheh, Faraz K

    2017-01-01

    A major challenge in systems biology is comprehensive mapping of protein interaction networks. Crucially, such interactions are often dynamic in nature, necessitating methods that can rapidly mine the interactome across varied conditions and treatments to reveal change in the interaction networks. Recently, we described a fast mass spectrometry-based method to reveal functional interactions in mammalian cells on a global scale, by revealing spatial colocalizations between proteins (COLA) (Mardakheh et al., Mol Biosyst 13:92-105, 2017). As protein localization and function are inherently linked, significant colocalization between two proteins is a strong indication for their functional interaction. COLA uses rapid complete subcellular fractionation, coupled with quantitative proteomics to generate a subcellular localization profile for each protein quantified by the mass spectrometer. Robust clustering is then applied to reveal significant similarities in protein localization profiles, indicative of colocalization.

  20. Portable X-ray fluorescence spectroscopy as a rapid screening technique for analysis of TiO2 and ZnO in sunscreens.

    PubMed

    Bairi, Venu Gopal; Lim, Jin-Hee; Quevedo, Ivan R; Mudalige, Thilak K; Linder, Sean W

    2016-02-01

    This investigation reports a rapid and simple screening technique for the quantification of titanium and zinc in commercial sunscreens using portable X-ray fluorescence spectroscopy (pXRF). A highly evolved technique, inductively coupled plasma-mass spectroscopy (ICP-MS) was chosen as a comparative technique to pXRF, and a good correlation (r 2 > 0.995) with acceptable variations (≤25%) in results between both techniques was observed. Analytical figures of merit such as detection limit, quantitation limit, and linear range of the method are reported for the pXRF technique. This method has a good linearity (r 2 > 0.995) for the analysis of titanium (Ti) in the range of 0.4-14.23 wt%, and zinc (Zn) in the range of 1.0-23.90 wt%. However, most commercial sunscreens contain organic ingredients, and these ingredients are known to cause matrix effects. The development of appropriate matrix matched working standards to obtain the calibration curve was found to be a major challenge for the pXRF measurements. In this study, we have overcome the matrix effect by using metal-free commercial sunscreens as a dispersing media for the preparation of working standards. An easy extension of this unique methodology for preparing working standards in different matrices was also reported. This method is simple, rapid, and cost-effective and, in comparison to conventional techniques (e.g., ICP-MS), did not generate toxic wastes during sample analysis.

  1. Portable X-ray fluorescence spectroscopy as a rapid screening technique for analysis of TiO2 and ZnO in sunscreens

    NASA Astrophysics Data System (ADS)

    Bairi, Venu Gopal; Lim, Jin-Hee; Quevedo, Ivan R.; Mudalige, Thilak K.; Linder, Sean W.

    2016-02-01

    This investigation reports a rapid and simple screening technique for the quantification of titanium and zinc in commercial sunscreens using portable X-ray fluorescence spectroscopy (pXRF). A highly evolved technique, inductively coupled plasma-mass spectroscopy (ICP-MS) was chosen as a comparative technique to pXRF, and a good correlation (r2 > 0.995) with acceptable variations (≤ 25%) in results between both techniques was observed. Analytical figures of merit such as detection limit, quantitation limit, and linear range of the method are reported for the pXRF technique. This method has a good linearity (r2 > 0.995) for the analysis of titanium (Ti) in the range of 0.4-14.23 wt%, and zinc (Zn) in the range of 1.0-23.90 wt%. However, most commercial sunscreens contain organic ingredients, and these ingredients are known to cause matrix effects. The development of appropriate matrix matched working standards to obtain the calibration curve was found to be a major challenge for the pXRF measurements. In this study, we have overcome the matrix effect by using metal-free commercial sunscreens as a dispersing media for the preparation of working standards. An easy extension of this unique methodology for preparing working standards in different matrices was also reported. This method is simple, rapid, and cost-effective and, in comparison to conventional techniques (e.g., ICP-MS), did not generate toxic wastes during sample analysis.

  2. Methods for processing high-throughput RNA sequencing data.

    PubMed

    Ares, Manuel

    2014-11-03

    High-throughput sequencing (HTS) methods for analyzing RNA populations (RNA-Seq) are gaining rapid application to many experimental situations. The steps in an RNA-Seq experiment require thought and planning, especially because the expense in time and materials is currently higher and the protocols are far less routine than those used for other high-throughput methods, such as microarrays. As always, good experimental design will make analysis and interpretation easier. Having a clear biological question, an idea about the best way to do the experiment, and an understanding of the number of replicates needed will make the entire process more satisfying. Whether the goal is capturing transcriptome complexity from a tissue or identifying small fragments of RNA cross-linked to a protein of interest, conversion of the RNA to cDNA followed by direct sequencing using the latest methods is a developing practice, with new technical modifications and applications appearing every day. Even more rapid are the development and improvement of methods for analysis of the very large amounts of data that arrive at the end of an RNA-Seq experiment, making considerations regarding reproducibility, validation, visualization, and interpretation increasingly important. This introduction is designed to review and emphasize a pathway of analysis from experimental design through data presentation that is likely to be successful, with the recognition that better methods are right around the corner. © 2014 Cold Spring Harbor Laboratory Press.

  3. Computer-assisted qualitative data analysis software.

    PubMed

    Cope, Diane G

    2014-05-01

    Advances in technology have provided new approaches for data collection methods and analysis for researchers. Data collection is no longer limited to paper-and-pencil format, and numerous methods are now available through Internet and electronic resources. With these techniques, researchers are not burdened with entering data manually and data analysis is facilitated by software programs. Quantitative research is supported by the use of computer software and provides ease in the management of large data sets and rapid analysis of numeric statistical methods. New technologies are emerging to support qualitative research with the availability of computer-assisted qualitative data analysis software (CAQDAS).CAQDAS will be presented with a discussion of advantages, limitations, controversial issues, and recommendations for this type of software use.

  4. Monosodium glutamate for simple photometric iron analysis

    NASA Astrophysics Data System (ADS)

    Prasetyo, E.

    2018-01-01

    Simple photometric method for iron analysis using monosodium glutamate (MSG) was proposed. The method could be used as an alternative method, which was technically simple, economic, quantitative, readily available, scientifically sound and environmental friendly. Rapid reaction of iron (III) with glutamate in sodium chloride-hydrochloric acid buffer (pH 2) to form red-brown complex was served as a basis in the photometric determination, which obeyed the range of iron (III) concentration 1.6 - 80 µg/ml. This method could be applied to determine iron concentration in soil with satisfactory results (accuracy and precision) compared to other photometric and atomic absorption spectrometry results.

  5. The development of silk fibroin scaffolds using an indirect rapid prototyping approach: morphological analysis and cell growth monitoring by spectral-domain optical coherence tomography.

    PubMed

    Liu, M J J; Chou, S M; Chua, C K; Tay, B C M; Ng, B K

    2013-02-01

    To date, naturally derived biomaterials are rarely used in advanced tissue engineering (TE) methods despite their superior biocompatibility. This is because these native materials, which consist mainly of proteins and polysaccharides, do not possess the ability to withstand harsh processing conditions. Unlike synthetic polymers, natural materials degrade and decompose rapidly in the presence of chemical solvents and high temperature, respectively. Thus, the fabrication of tissue scaffolds using natural biomaterials is often carried out using conventional techniques, where the efficiency in mass transport of nutrients and removal of waste products within the construct is compromised. The present study identified silk fibroin (SF) protein as a suitable material for the application of rapid prototyping (RP) or additive manufacturing (AM) technology. Using the indirect RP method, via the use of a mould, SF tissue scaffolds with both macro- and micro-morphological features can be produced and qualitatively examined by spectral-domain optical coherence tomography (SD-OCT). The advanced imaging technique showed the ability to differentiate the cells and SF material by producing high contrasting images, therefore suggesting the method as a feasible alternative to the histological analysis of cell growth within tissue scaffolds. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Addleman, Raymond S.; Naes, Benjamin E.; McNamara, Bruce K.

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmentalmore » sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2F 2 and UO 2(NO 3) 2, U 3O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.« less

  7. Most Probable Number Rapid Viability PCR Method to Detect Viable Spores of Bacillus anthracis in Swab Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Letant, S E; Kane, S R; Murphy, G A

    2008-05-30

    This note presents a comparison of Most-Probable-Number Rapid Viability (MPN-RV) PCR and traditional culture methods for the quantification of Bacillus anthracis Sterne spores in macrofoam swabs generated by the Centers for Disease Control and Prevention (CDC) for a multi-center validation study aimed at testing environmental swab processing methods for recovery, detection, and quantification of viable B. anthracis spores from surfaces. Results show that spore numbers provided by the MPN RV-PCR method were in statistical agreement with the CDC conventional culture method for all three levels of spores tested (10{sup 4}, 10{sup 2}, and 10 spores) even in the presence ofmore » dirt. In addition to detecting low levels of spores in environmental conditions, the MPN RV-PCR method is specific, and compatible with automated high-throughput sample processing and analysis protocols.« less

  8. Proximate Composition Analysis.

    PubMed

    2016-01-01

    The proximate composition of foods includes moisture, ash, lipid, protein and carbohydrate contents. These food components may be of interest in the food industry for product development, quality control (QC) or regulatory purposes. Analyses used may be rapid methods for QC or more accurate but time-consuming official methods. Sample collection and preparation must be considered carefully to ensure analysis of a homogeneous and representative sample, and to obtain accurate results. Estimation methods of moisture content, ash value, crude lipid, total carbohydrates, starch, total free amino acids and total proteins are put together in a lucid manner.

  9. Direct analysis in real time mass spectrometry and multivariate data analysis: a novel approach to rapid identification of analytical markers for quality control of traditional Chinese medicine preparation.

    PubMed

    Zeng, Shanshan; Wang, Lu; Chen, Teng; Wang, Yuefei; Mo, Huanbiao; Qu, Haibin

    2012-07-06

    The paper presents a novel strategy to identify analytical markers of traditional Chinese medicine preparation (TCMP) rapidly via direct analysis in real time mass spectrometry (DART-MS). A commonly used TCMP, Danshen injection, was employed as a model. The optimal analysis conditions were achieved by measuring the contribution of various experimental parameters to the mass spectra. Salvianolic acids and saccharides were simultaneously determined within a single 1-min DART-MS run. Furthermore, spectra of Danshen injections supplied by five manufacturers were processed with principal component analysis (PCA). Obvious clustering was observed in the PCA score plot, and candidate markers were recognized from the contribution plots of PCA. The suitability of potential markers was then confirmed by contrasting with the results of traditional analysis methods. Using this strategy, fructose, glucose, sucrose, protocatechuic aldehyde and salvianolic acid A were rapidly identified as the markers of Danshen injections. The combination of DART-MS with PCA provides a reliable approach to the identification of analytical markers for quality control of TCMP. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. High-Throughput Method for Strontium Isotope Analysis by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wall, Andrew J.; Capo, Rosemary C.; Stewart, Brian W.

    2016-09-22

    This technical report presents the details of the Sr column configuration and the high-throughput Sr separation protocol. Data showing the performance of the method as well as the best practices for optimizing Sr isotope analysis by MC-ICP-MS is presented. Lastly, this report offers tools for data handling and data reduction of Sr isotope results from the Thermo Scientific Neptune software to assist in data quality assurance, which help avoid issues of data glut associated with high sample throughput rapid analysis.

  11. High-Throughput Method for Strontium Isotope Analysis by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hakala, Jacqueline Alexandra

    2016-11-22

    This technical report presents the details of the Sr column configuration and the high-throughput Sr separation protocol. Data showing the performance of the method as well as the best practices for optimizing Sr isotope analysis by MC-ICP-MS is presented. Lastly, this report offers tools for data handling and data reduction of Sr isotope results from the Thermo Scientific Neptune software to assist in data quality assurance, which help avoid issues of data glut associated with high sample throughput rapid analysis.

  12. Periodate oxidation of nanoscaled magnetic dextran composites

    NASA Astrophysics Data System (ADS)

    Hong, Xia; Guo, Wei; Yuan, Hang; Li, Jun; Liu, Yanmei; Ma, Lan; Bai, Yubai; Li, Tiejin

    2004-02-01

    Highly hydrophilic, uniform and nontoxic magnetic fluids consisting of magnetite (Fe 3O 4) and dextran were prepared. A periodate oxidation method was used to further activate the magnetic dextran, forming magnetic polyaldehyde-dextran, which could be conjugated to biomolecules such as proteins or antibodies. Oxidated Magnetic dextran composites were characterized by TEM, XRD and SQUID magnetometry. Moreover, a flexible, rapid and simple method to detect aldehydes was introduced to the magnetic composite system by utilizing 2,4-dinitrophenylhydrazine reagent. The result of the quantitative analysis of aldehyde was given by thermogravimetric analysis and elemental analysis.

  13. Cellular phone-based image acquisition and quantitative ratiometric method for detecting cocaine and benzoylecgonine for biological and forensic applications.

    PubMed

    Cadle, Brian A; Rasmus, Kristin C; Varela, Juan A; Leverich, Leah S; O'Neill, Casey E; Bachtell, Ryan K; Cooper, Donald C

    2010-01-01

    Here we describe the first report of using low-cost cellular or web-based digital cameras to image and quantify standardized rapid immunoassay strips as a new point-of-care diagnostic and forensics tool with health applications. Quantitative ratiometric pixel density analysis (QRPDA) is an automated method requiring end-users to utilize inexpensive (∼ $1 USD/each) immunotest strips, a commonly available web or mobile phone camera or scanner, and internet or cellular service. A model is described whereby a central computer server and freely available IMAGEJ image analysis software records and analyzes the incoming image data with time-stamp and geo-tag information and performs the QRPDA using custom JAVA based macros (http://www.neurocloud.org). To demonstrate QRPDA we developed a standardized method using rapid immunotest strips directed against cocaine and its major metabolite, benzoylecgonine. Images from standardized samples were acquired using several devices, including a mobile phone camera, web cam, and scanner. We performed image analysis of three brands of commercially available dye-conjugated anti-cocaine/benzoylecgonine (COC/BE) antibody test strips in response to three different series of cocaine concentrations ranging from 0.1 to 300 ng/ml and BE concentrations ranging from 0.003 to 0.1 ng/ml. This data was then used to create standard curves to allow quantification of COC/BE in biological samples. Across all devices, QRPDA quantification of COC and BE proved to be a sensitive, economical, and faster alternative to more costly methods, such as gas chromatography-mass spectrometry, tandem mass spectrometry, or high pressure liquid chromatography. The limit of detection was determined to be between 0.1 and 5 ng/ml. To simulate conditions in the field, QRPDA was found to be robust under a variety of image acquisition and testing conditions that varied temperature, lighting, resolution, magnification and concentrations of biological fluid in a sample. To determine the effectiveness of the QRPDA method for quantifying cocaine in biological samples, mice were injected with a sub-locomotor activating dose of cocaine (5 mg/kg; i.p.) and were found to have detectable levels of COC/BE in their urine (160.6 ng/ml) and blood plasma (8.1 ng/ml) after 15-30 minutes. By comparison rats self-administering cocaine in a 4 hour session obtained a final BE blood plasma level of 910 ng/ml with an average of 62.5 infusions. It is concluded that automated QRPDA is a low-cost, rapid and highly sensitive method for the detection of COC/BE with health, forensics, and bioinformatics application and the potential to be used with other rapid immunotest strips directed at several other targets. Thus, this report serves as a general reference and method describing the use of image analysis of lateral flow rapid test strips.

  14. Impacts of Earth rotation parameters on GNSS ultra-rapid orbit prediction: Derivation and real-time correction

    NASA Astrophysics Data System (ADS)

    Wang, Qianxin; Hu, Chao; Xu, Tianhe; Chang, Guobin; Hernández Moraleda, Alberto

    2017-12-01

    Analysis centers (ACs) for global navigation satellite systems (GNSSs) cannot accurately obtain real-time Earth rotation parameters (ERPs). Thus, the prediction of ultra-rapid orbits in the international terrestrial reference system (ITRS) has to utilize the predicted ERPs issued by the International Earth Rotation and Reference Systems Service (IERS) or the International GNSS Service (IGS). In this study, the accuracy of ERPs predicted by IERS and IGS is analyzed. The error of the ERPs predicted for one day can reach 0.15 mas and 0.053 ms in polar motion and UT1-UTC direction, respectively. Then, the impact of ERP errors on ultra-rapid orbit prediction by GNSS is studied. The methods for orbit integration and frame transformation in orbit prediction with introduced ERP errors dominate the accuracy of the predicted orbit. Experimental results show that the transformation from the geocentric celestial references system (GCRS) to ITRS exerts the strongest effect on the accuracy of the predicted ultra-rapid orbit. To obtain the most accurate predicted ultra-rapid orbit, a corresponding real-time orbit correction method is developed. First, orbits without ERP-related errors are predicted on the basis of ITRS observed part of ultra-rapid orbit for use as reference. Then, the corresponding predicted orbit is transformed from GCRS to ITRS to adjust for the predicted ERPs. Finally, the corrected ERPs with error slopes are re-introduced to correct the predicted orbit in ITRS. To validate the proposed method, three experimental schemes are designed: function extrapolation, simulation experiments, and experiments with predicted ultra-rapid orbits and international GNSS Monitoring and Assessment System (iGMAS) products. Experimental results show that using the proposed correction method with IERS products considerably improved the accuracy of ultra-rapid orbit prediction (except the geosynchronous BeiDou orbits). The accuracy of orbit prediction is enhanced by at least 50% (error related to ERP) when a highly accurate observed orbit is used with the correction method. For iGMAS-predicted orbits, the accuracy improvement ranges from 8.5% for the inclined BeiDou orbits to 17.99% for the GPS orbits. This demonstrates that the correction method proposed by this study can optimize the ultra-rapid orbit prediction.

  15. A rapid, automated approach to optimisation of multiple reaction monitoring conditions for quantitative bioanalytical mass spectrometry.

    PubMed

    Higton, D M

    2001-01-01

    An improvement to the procedure for the rapid optimisation of mass spectrometry (PROMS), for the development of multiple reaction methods (MRM) for quantitative bioanalytical liquid chromatography/tandem mass spectrometry (LC/MS/MS), is presented. PROMS is an automated protocol that uses flow-injection analysis (FIA) and AppleScripts to create methods and acquire the data for optimisation. The protocol determines the optimum orifice potential, the MRM conditions for each compound, and finally creates the MRM methods needed for sample analysis. The sensitivities of the MRM methods created by PROMS approach those created manually. MRM method development using PROMS currently takes less than three minutes per compound compared to at least fifteen minutes manually. To further enhance throughput, approaches to MRM optimisation using one injection per compound, two injections per pool of five compounds and one injection per pool of five compounds have been investigated. No significant difference in the optimised instrumental parameters for MRM methods were found between the original PROMS approach and these new methods, which are up to ten times faster. The time taken for an AppleScript to determine the optimum conditions and build the MRM methods is the same with all approaches. Copyright 2001 John Wiley & Sons, Ltd.

  16. [Isolation and identification methods of enterobacteria group and its technological advancement].

    PubMed

    Furuta, Itaru

    2007-08-01

    In the last half-century, isolation and identification methods of enterobacteria groups have markedly improved by technological advancement. Clinical microbiology tests have changed overtime from tube methods to commercial identification kits and automated identification. Tube methods are the original method for the identification of enterobacteria groups, that is, a basically essential method to recognize bacterial fermentation and biochemical principles. In this paper, traditional tube tests are discussed, such as the utilization of carbohydrates, indole, methyl red, and citrate and urease tests. Commercial identification kits and automated instruments by computer based analysis as current methods are also discussed, and those methods provide rapidity and accuracy. Nonculture techniques of nucleic acid typing methods using PCR analysis, and immunochemical methods using monoclonal antibodies can be further developed.

  17. Blade loss transient dynamic analysis of turbomachinery

    NASA Technical Reports Server (NTRS)

    Stallone, M. J.; Gallardo, V.; Storace, A. F.; Bach, L. J.; Black, G.; Gaffney, E. F.

    1982-01-01

    This paper reports on work completed to develop an analytical method for predicting the transient non-linear response of a complete aircraft engine system due to the loss of a fan blade, and to validate the analysis by comparing the results against actual blade loss test data. The solution, which is based on the component element method, accounts for rotor-to-casing rubs, high damping and rapid deceleration rates associated with the blade loss event. A comparison of test results and predicted response show good agreement except for an initial overshoot spike not observed in test. The method is effective for analysis of large systems.

  18. Development of a rapid, simple and sensitive HPLC-FLD method for determination of rhodamine B in chili-containing products.

    PubMed

    Qi, Ping; Lin, Zhihao; Li, Jiaxu; Wang, ChengLong; Meng, WeiWei; Hong, Hong; Zhang, Xuewu

    2014-12-01

    In this work, a simple, rapid and sensitive analytical method for the determination of rhodamine B in chili-containing foodstuffs is described. The dye is extracted from samples with methanol and analysed without further cleanup procedure by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD). The influence of matrix fluorescent compounds (capsaicin and dihydrocapsaicin) on the analysis was overcome by the optimisation of mobile-phase composition. The limit of determination (LOD) and limit of quantification (LOQ) were 3.7 and 10 μg/kg, respectively. Validation data show a good repeatability and within-lab reproducibility with relative standard deviations <10%. The overall recoveries are in the range of 98-103% in chili powder and in the range of 87-100% in chili oil depending on the concentration of rhodamine B in foodstuffs. This method is suitable for the routine analysis of rhodamine B due to its sensitivity, simplicity, reasonable time and cost. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Rapid analysis of 3,4-methylenedioxymethamphetamine: a comparison of nonaqueous capillary electrophoresis/fluorescence detection with GC/MS.

    PubMed

    Fang, Ching; Chung, Yu-Lin; Liu, Ju-Tsung; Lin, Cheng-Huang

    2002-02-18

    Because of the increasing use of 3,4-methylenedioxymethamphetamine (3,4-MDMA), a rapid and sensitive analytical technique is required for its detection and determination. Using nonaqueous capillary electrophoresis/fluorescence spectroscopy (NACE/FS) detection, it is possible to determine this drug at the level 0.5 ppm without any pre-treatment in less than 5 min. After liquid-liquid extraction, the sample can be condensed and a detection limit of 3,4-MDMA in urine of 50 ppb (S/N = 3) can be achieved. The precision of the method was evaluated by measuring the repeatability and intermediate precision of migration time and the corrected peak height by comparison with a 3,4-MDMA-D5 internal standard. With the conventional GC/MS method, it is necessary to derivatize the 3,4-MDMA before injection and the GC migration time also is in excess of 20 min. Therefore, NACE/FS represents a good complementary method to GC/MS for use in forensic analysis.

  20. Evaluation of an inhouse rapid ELISA test for detection of giardia in domestic sheep (Ovis aries).

    PubMed

    Wilson, Jolaine M; Hankenson, F Claire

    2010-11-01

    Sheep (Ovis aries) are increasingly used at our institution as models of human disease. Within the research environment, routine husbandry and handling of sheep has potential for transmission of zoonotic agents, including Giardia. The prevalence of Giardia in sheep may approach 68%. Classic diagnostic testing involves microscopic examination for fecal cysts or trophozoites; however, limitations of microscopy include time, labor, and potential false-negative results due to intermittent shedding. We wished to determine whether a commercial rapid ELISA used for Giardia detection in dogs and cats could be used in sheep. Fecal samples collected from sheep (n = 93) were tested with a combination of 6 methods: reference laboratory fecal flotation, reference laboratory ELISA, inhouse fecal flotation, and commercially available tests (enzyme immunoassay, direct fluorescence antibody assay, and rapid ELISA). Prevalence of Giardia infection in facility sheep was 11.8% (11 of 93 animals). Of the 11 samples considered positive, 3 were confirmed by multiple testing methods, and 5 were positive by microscopy alone. Inhouse fecal flotation for 8 samples was positive on only 1 of 2 consecutive testing days. The rapid ELISA test exhibited 0% sensitivity for sheep giardiasis. Overall, the examined methods had low sensitivities and low positive predictive values. Despite limitations, microscopic analysis of repeat fecal samples remained the most accurate diagnostic method for ovine giardiasis among the methods tested.

  1. Characterizing natural colloidal/particulate-protein interactions using fluorescence-based techniques and principal component analysis.

    PubMed

    Peiris, Ramila H; Ignagni, Nicholas; Budman, Hector; Moresoli, Christine; Legge, Raymond L

    2012-09-15

    Characterization of the interactions between natural colloidal/particulate- and protein-like matter is important for understanding their contribution to different physiochemical phenomena like membrane fouling, adsorption of bacteria onto surfaces and various applications of nanoparticles in nanomedicine and nanotoxicology. Precise interpretation of the extent of such interactions is however hindered due to the limitations of most characterization methods to allow rapid, sensitive and accurate measurements. Here we report on a fluorescence-based excitation-emission matrix (EEM) approach in combination with principal component analysis (PCA) to extract information related to the interaction between natural colloidal/particulate- and protein-like matter. Surface plasmon resonance (SPR) analysis and fiber-optic probe based surface fluorescence measurements were used to confirm that the proposed approach can be used to characterize colloidal/particulate-protein interactions at the physical level. This method has potential to be a fundamental measurement of these interactions with the advantage that it can be performed rapidly and with high sensitivity. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Rapid characterization of transgenic and non-transgenic soybean oils by chemometric methods using NIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Luna, Aderval S.; da Silva, Arnaldo P.; Pinho, Jéssica S. A.; Ferré, Joan; Boqué, Ricard

    Near infrared (NIR) spectroscopy and multivariate classification were applied to discriminate soybean oil samples into non-transgenic and transgenic. Principal Component Analysis (PCA) was applied to extract relevant features from the spectral data and to remove the anomalous samples. The best results were obtained when with Support Vectors Machine-Discriminant Analysis (SVM-DA) and Partial Least Squares-Discriminant Analysis (PLS-DA) after mean centering plus multiplicative scatter correction. For SVM-DA the percentage of successful classification was 100% for the training group and 100% and 90% in validation group for non transgenic and transgenic soybean oil samples respectively. For PLS-DA the percentage of successful classification was 95% and 100% in training group for non transgenic and transgenic soybean oil samples respectively and 100% and 80% in validation group for non transgenic and transgenic respectively. The results demonstrate that NIR spectroscopy can provide a rapid, nondestructive and reliable method to distinguish non-transgenic and transgenic soybean oils.

  3. Designing a Micromixer for Rolling Circle Amplification in Cancer Biomarker Detection

    NASA Astrophysics Data System (ADS)

    Altural, Hayriye

    2015-03-01

    Rolling circle amplification (RCA) is an alternative method to the Polymerase Chain Reaction based amplification for point-of-care (POC) diagnosis. In future personalized cancer diagnostic for POC applications, smaller, faster and cheaper methods are needed instead of costly and time-consuming laboratory tests. Microfluidic chips can perform the detection of cancer biomarkers within less analysis time, and provide for improvement in the sensitivity and specificity required for biochemical analysis as well. Rapid mixing is essential in the chips used in cancer diagnostic. The goal of this study is to design a micromixer for rapid RCA-based analysis and develop the assay time in cancer biomarker detection. By combining assays with micromixers, multi-step bioreactions in microfluidic chips may be achieved with minimal external control. Here, simulation results related to the micromixer are obtained by COMSOL software. The Scientific and Technological Research Council of Turkey (TUBITAK) is acknowledged for granting of H. Altural postdoctoral study in the framework of TUBITAK-BIDEB 2219-International Postdoctoral Research Scholarship Program.

  4. Incorporation of flow injection analysis with dual-wavelength overlapping resonance Rayleigh scattering for rapid determination of malachite green and its metabolite in fish.

    PubMed

    Zhu, Jinghui; Qin, Mingyou; Liu, Shaopu; Liu, Zhongfang; Yang, Jidong; Hu, Xiaoli

    2014-09-15

    A flow injection analysis (FIA) system combined with dual-wavelength overlapping resonance Rayleigh scattering (DWO-RRS) has been established and validated for rapid determination of malachite green (MG) and its metabolite in fish samples. Under experimental condition, MG would react with Erythrosin (Ery) to form ion-association complexes, resulting in the occurrence of two RRS peaks and a dramatic enhancement of RRS intensity. The maximum RRS peaks were located at 286 nm and 337 nm. It is noted that the increments of both of these two peaks were proportional to the concentration of MG. The detection limit of DWO-RRS was 1.5 ng/mL, which was comparable to several reported methods. Moreover, the results of real sample analysis exhibited an acceptable recovery between 97.5% and 103.6%, indicating that the method had good reproducibility. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Macro-fingerprint analysis-through-separation of licorice based on FT-IR and 2DCOS-IR

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Ping; Xu, Changhua; Yang, Yan; Li, Jin; Chen, Tao; Li, Zheng; Cui, Weili; Zhou, Qun; Sun, Suqin; Li, Huifen

    2014-07-01

    In this paper, a step-by-step analysis-through-separation method under the navigation of multi-step IR macro-fingerprint (FT-IR integrated with second derivative IR (SD-IR) and 2DCOS-IR) was developed for comprehensively characterizing the hierarchical chemical fingerprints of licorice from entirety to single active components. Subsequently, the chemical profile variation rules of three parts (flavonoids, saponins and saccharides) in the separation process were holistically revealed and the number of matching peaks and correlation coefficients with standards of pure compounds was increasing along the extracting directions. The findings were supported by UPLC results and a verification experiment of aqueous separation process. It has been demonstrated that the developed multi-step IR macro-fingerprint analysis-through-separation approach could be a rapid, effective and integrated method not only for objectively providing comprehensive chemical characterization of licorice and all its separated parts, but also for rapidly revealing the global enrichment trend of the active components in licorice separation process.

  6. The use of wavelength dispersive X-ray fluorescence in the identification of the elemental composition of vanilla samples and the determination of the geographic origin by discriminant function analysis.

    PubMed

    Hondrogiannis, Ellen; Rotta, Kathryn; Zapf, Charles M

    2013-03-01

    Sixteen elements found in 37 vanilla samples from Madagascar, Uganda, India, Indonesia (all Vanilla planifolia species), and Papa New Guinea (Vanilla tahitensis species) were measured by wavelength dispersive X-ray fluorescence (WDXRF) spectroscopy for the purpose of determining the elemental concentrations to discriminate among the origins. Pellets were prepared of the samples and elemental concentrations were calculated based on calibration curves created using 4 Natl. Inst. of Standards and Technology (NIST) standards. Discriminant analysis was used to successfully classify the vanilla samples by their species and their geographical region. Our method allows for higher throughput in the rapid screening of vanilla samples in less time than analytical methods currently available. Wavelength dispersive X-ray fluorescence spectroscopy and discriminant function analysis were used to classify vanilla from different origins resulting in a model that could potentially serve to rapidly validate these samples before purchasing from a producer. © 2013 Institute of Food Technologists®

  7. The microdopant effects of surfactant elements on structure-phase transitions during the rapid quenched crystallization of Fe-C-based melts

    NASA Astrophysics Data System (ADS)

    Polukhin, V. A.; Belyakova, R. M.; Rigmant, L. K.

    2008-02-01

    The nature of microdopant effects of surfactant Te and H2 reagents on structure-phase transitions in rapidly quenched and crystallized eutectic Fe-C-based melts were studied by experimental and computer methods. On the base of results of statistic-geometrical analysis the new information about the structure changes in multi-scaling systems -from meso- to nano-ones were obtained.

  8. [Special application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in clinical microbiological diagnostics].

    PubMed

    Nagy, Erzsébet; Abrók, Marianna; Bartha, Noémi; Bereczki, László; Juhász, Emese; Kardos, Gábor; Kristóf, Katalin; Miszti, Cecilia; Urbán, Edit

    2014-09-21

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry as a new possibility for rapid identification of bacteria and fungi revolutionized the clinical microbiological diagnostics. It has an extreme importance in the routine microbiological laboratories, as identification of the pathogenic species rapidly will influence antibiotic selection before the final determination of antibiotic resistance of the isolate. The classical methods for identification of bacteria or fungi, based on biochemical tests, are influenced by many environmental factors. The matrix-assisted laser desorption ionization time-of-flight mass spectrometry is a rapid method which is able to identify a great variety of the isolated bacteria and fungi based on the composition of conserved ribosomal proteins. Recently several other applications of the method have also been investigated such as direct identification of pathogens from the positive blood cultures. There are possibilities to identify bacteria from the urine samples in urinary tract infection or from other sterile body fluids. Using selective enrichment broth Salmonella sp from the stool samples can be identified more rapidly, too. The extended spectrum beta-lactamase or carbapenemase production of the isolated bacteria can be also detected by this method helping the antibiotic selection in some cases. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry based methods are suitable to investigate changes in deoxyribonucleic acid or ribonucleic acid, to carry out rapid antibiotic resistance determination or other proteomic analysis. The aim of this paper is to give an overview about present possibilities of using this technique in the clinical microbiological routine procedures.

  9. Differentiation of live and dead salmonella cells using fourier transform infrared (FTIR) spectroscopy and principle component analysis (PCA) technique

    USDA-ARS?s Scientific Manuscript database

    Various technologies have been developed for pathogen detection using optical, electrochemical, biochemical and physical properties. Conventional microbiological methods need time from days to week to get the result. Though this method is very sensitive and accurate, a rapid detection of pathogens i...

  10. Calculation of the bending stresses in helicopter rotor blades

    NASA Technical Reports Server (NTRS)

    De Guillenchmidt, P

    1951-01-01

    A comparatively rapid method is presented for determining theoretically the bending stresses of helicopter rotor blades in forward flight. The method is based on the analysis of the properties of a vibrating beam, and its uniqueness lies in the simple solution of the differential equation which governs the motion of the bent blades.

  11. An Educational Model for Disruption of Bacteria for Protein Studies.

    ERIC Educational Resources Information Center

    Bhaduri, Saumya; Demchick, Paul H.

    1984-01-01

    A simple, rapid, and safe method has been developed for disrupting bacterial cells for protein studies. The method involved stepwise treatment of cells with acetone and with sodium dodecyl sulfate solution to allow extraction of cellular proteins for analysis by polyacrylamide gel electrophoresis. Applications for instructional purposes are noted.…

  12. Einstein Slew Survey: Data analysis innovations

    NASA Technical Reports Server (NTRS)

    Elvis, Martin S.; Plummer, David; Schachter, Jonathan F.; Fabbiano, G.

    1992-01-01

    Several new methods were needed in order to make the Einstein Slew X-ray Sky Survey. The innovations which enabled the Slew Survey to be done are summarized. These methods included experimental approach to large projects, parallel processing on a LAN, percolation source detection, minimum action identifications, and rapid dissemination of the whole data base.

  13. A Simple and Inexpensive Capillary Holder for Thin-Layer Chromatography

    ERIC Educational Resources Information Center

    Pintea, Beniamin-Nicolae V.

    2011-01-01

    Thin-layer chromatography (TLC) is a widely used method of qualitative analysis in organic synthesis, as it uniquely combines low cost, rapidity, simplicity, versatility, small quantities of sample and low detection limits. The simplest and most economical method for the application of samples onto TLC plates is by hand, using glass capillaries.…

  14. The flame photometric determination of calcium in phosphate, carbonate, and silicate rocks

    USGS Publications Warehouse

    Kramer, H.

    1957-01-01

    A flame photometric method of determining calcium in phosphate, carbonate, and silicate locks has been developed Aluminum and phosphate interference was overcome by the addition of a large excess of magnesium. The method is rapid and suitable for routine analysis Results obtained are within ?? 2% of the calcium oxide content. ?? 1957.

  15. Rapid analysis of ultraviolet filters using dispersive liquid-liquid microextraction coupled to headspace gas chromatography and mass spectrometry.

    PubMed

    Pierson, Stephen A; Trujillo-Rodríguez, María J; Anderson, Jared L

    2018-05-29

    An ionic-liquid-based in situ dispersive liquid-liquid microextraction method coupled to headspace gas chromatography and mass spectrometry was developed for the rapid analysis of ultraviolet filters. The chemical structures of five ionic liquids were specifically designed to incorporate various functional groups for the favorable extraction of the target analytes. Extraction parameters including ionic liquid mass, molar ratio of ionic liquid to metathesis reagent, vortex time, ionic strength, pH, and total sample volume were studied and optimized. The effect of the headspace temperature and volume during the headspace sampling step was also evaluated to increase the sensitivity of the method. The optimized procedure is fast as it only required ∼7-10 min per extraction and allowed for multiple extractions to be performed simultaneously. In addition, the method exhibited high precision, good linearity, and low limits of detection for six ultraviolet filters in aqueous samples. The developed method was applied to both pool and lake water samples attaining acceptable relative recovery values. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. An iterative method for analysis of hadron ratios and Spectra in relativistic heavy-ion collisions

    NASA Astrophysics Data System (ADS)

    Choi, Suk; Lee, Kang Seog

    2016-04-01

    A new iteration method is proposed for analyzing both the multiplicities and the transverse momentum spectra measured within a small rapidity interval with low momentum cut-off without assuming the invariance of the rapidity distribution under the Lorentz-boost and is applied to the hadron data measured by the ALICE collaboration for Pb+Pb collisions at √ {^sNN} = 2.76 TeV. In order to correctly consider the resonance contribution only to the small rapidity interval measured, we only consider ratios involving only those hadrons whose transverse momentum spectrum is available. In spite of the small number of ratios considered, the quality of fitting both of the ratios and the transverse momentum spectra is excellent. Also, the calculated ratios involving strange baryons with the fitted parameters agree with the data surprisingly well.

  17. Rapid flow cytometry analysis of antimicrobial properties of nettle powder and cranberry powder

    NASA Astrophysics Data System (ADS)

    Hattuniemi, Maarit; Korhonen, Johanna; Jaakkola, Mari; Räty, Jarkko; Virtanen, Vesa

    2010-11-01

    Both nettle (Urtica dioica) and cranberry (Vaccinium oxycoccus) are widely known to have good influence on health. The aim of this study was to investigate antimicrobial properties of nettle powder and cranberry powder against Escherichia coli (E. coli) and monitor the growth of the bacteria by a rapid flow cytometry (FCM) method. For FCM measurements samples were stained with fluorescent dyes. The inhibitory effects of plant material on growth of E. coli were estimated by comparing the results of control sample (E. coli) to E. coli samples with plant material. FCM offers both a brilliant tool to investigate the kinetics of the growth of bacterium, since subsamples can be taken from the same liquid medium during the growing period and with fluorescent dyes a rapid method to investigate viability of the bacterium.

  18. Computer-Aided Design Of Turbine Blades And Vanes

    NASA Technical Reports Server (NTRS)

    Hsu, Wayne Q.

    1988-01-01

    Quasi-three-dimensional method for determining aerothermodynamic configuration of turbine uses computer-interactive analysis and design and computer-interactive graphics. Design procedure executed rapidly so designer easily repeats it to arrive at best performance, size, structural integrity, and engine life. Sequence of events in aerothermodynamic analysis and design starts with engine-balance equations and ends with boundary-layer analysis and viscous-flow calculations. Analysis-and-design procedure interactive and iterative throughout.

  19. Introducing AAA-MS, a rapid and sensitive method for amino acid analysis using isotope dilution and high-resolution mass spectrometry.

    PubMed

    Louwagie, Mathilde; Kieffer-Jaquinod, Sylvie; Dupierris, Véronique; Couté, Yohann; Bruley, Christophe; Garin, Jérôme; Dupuis, Alain; Jaquinod, Michel; Brun, Virginie

    2012-07-06

    Accurate quantification of pure peptides and proteins is essential for biotechnology, clinical chemistry, proteomics, and systems biology. The reference method to quantify peptides and proteins is amino acid analysis (AAA). This consists of an acidic hydrolysis followed by chromatographic separation and spectrophotometric detection of amino acids. Although widely used, this method displays some limitations, in particular the need for large amounts of starting material. Driven by the need to quantify isotope-dilution standards used for absolute quantitative proteomics, particularly stable isotope-labeled (SIL) peptides and PSAQ proteins, we developed a new AAA assay (AAA-MS). This method requires neither derivatization nor chromatographic separation of amino acids. It is based on rapid microwave-assisted acidic hydrolysis followed by high-resolution mass spectrometry analysis of amino acids. Quantification is performed by comparing MS signals from labeled amino acids (SIL peptide- and PSAQ-derived) with those of unlabeled amino acids originating from co-hydrolyzed NIST standard reference materials. For both SIL peptides and PSAQ standards, AAA-MS quantification results were consistent with classical AAA measurements. Compared to AAA assay, AAA-MS was much faster and was 100-fold more sensitive for peptide and protein quantification. Finally, thanks to the development of a labeled protein standard, we also extended AAA-MS analysis to the quantification of unlabeled proteins.

  20. 1H-NMR METABONOMICS ANALYSIS OF SERA DIFFERENTIATES BETWEEN MAMMARY TUMOR-BEARING MICE AND HEALTHY CONTROLS

    EPA Science Inventory

    Global analysis of 1H-NMR spectra of serum is an appealing approach for the rapid detection of cancer. To evaluate the usefulness of this method in distinguishing between mammary tumor-bearing mice and healthy controls, we conducted 1H-NMR metabonomic analyses on serum samples ob...

  1. Factors Affecting Accuracy and Time Requirements of a Glucose Oxidase-Peroxidase Assay for Determination of Glucose

    USDA-ARS?s Scientific Manuscript database

    Accurate and rapid assays for glucose are desirable for analysis of glucose and starch in food and feedstuffs. An established colorimetric glucose oxidase-peroxidase method for glucose was modified to reduce analysis time, and evaluated for factors that affected accuracy. Time required to perform t...

  2. Simple Approach for the Rapid Detection of Alternariol in Pear Fruit by Surface-Enhanced Raman Scattering with Pyridine-Modified Silver Nanoparticles.

    PubMed

    Pan, Ting-Tiao; Sun, Da-Wen; Pu, Hongbin; Wei, Qingyi

    2018-03-07

    A simple method based on surface-enhanced Raman scattering (SERS) was developed for the rapid determination of alternariol (AOH) in pear fruits using an easily prepared silver-nanoparticle (AgNP) substrate. The AgNP substrate was modified by pyridine to circumvent the weak affinity of the AOH molecules to the silver surface and to improve the sensitivity of detection. Quantitative analysis was performed in AOH solutions at concentrations ranging from 3.16 to 316.0 μg/L, and the limit of detection was 1.30 μg/L. The novel method was also applied to the detection of AOH residues in pear fruits purchased from the market and in pear fruits that were artificially inoculated with Alternaria alternata. AOH was not found in any of the fresh fruit, whereas it resided in the rotten and inoculated fruits. Finally, the SERS method was cross validated against HPLC. It was revealed that the SERS method has great potential utility in the rapid detection of AOH in pear fruits and other agricultural products.

  3. Ultrasonic-assisted deacetylation of cellulose acetate nanofibers: A rapid method to produce cellulose nanofibers.

    PubMed

    Ahmed, Farooq; Ayoub Arbab, Alvira; Jatoi, Abdul Wahab; Khatri, Muzamil; Memon, Najma; Khatri, Zeeshan; Kim, Ick Soo

    2017-05-01

    Herein we report a rapid method for deacetylation of cellulose acetate (CA) nanofibers in order to produce cellulose nanofibers using ultrasonic energy. The CA nanofibers were fabricated via electrospinning thereby treated with NaOH and NaOH/EtOH solutions at various pH levels for 30, 60 and 90min assisted by ultrasonic energy. The nanofiber webs were optimized by degree of deacetylation (DD%) and wicking behavior. The resultant nanofibers were further characterized by FTIR, SEM, WAXD, DSC analysis. The DD% and FTIR results confirmed a complete conversion of CA nanofibers to cellulose nanofibers within 1h with substantial increase of wicking height. Nanofibers morphology under SEM showed slightly swelling and no damage of nanofibers observed by use of ultrasonic energy. The results of ultrasonic-assisted deacetylation are comparable with the conventional deacetylation. Our rapid method offers substantially reduced deacetylation time from 30h to just 1h, thanks to the ultrasonic energy. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Combination of SDS-PAGE and intact mass analysis for rapid determination of heterogeneities in monoclonal antibody therapeutics.

    PubMed

    Yamada, Hideaki; Matsumura, Chiemi; Yamada, Keita; Teshima, Koichiro; Hiroshima, Takashi; Kinoshita, Mitsuhiro; Suzuki, Shigeo; Kakehi, Kazuaki

    2017-05-01

    mAbs are currently mainstream in biopharmaceuticals, and their market has been growing due to their high target specificity. Characterization of heterogeneities in mAbs is performed to secure their quality and safety by physicochemical analyses. However, they require time-consuming task, which often strain the resources of drug development in pharmaceuticals. Rapid and direct method to determine the heterogeneities should be a powerful tool for pharmaceutical analysis. Considering the advantages of electrophoresis and MS, this study addresses the combination of SDS-PAGE and intact mass analysis, which provides direct, rapid, and orthogonal determination of heterogeneities in mAb therapeutics. mAb therapeutics that migrated in SDS-PAGE were recovered from gel by treatment with SDC-containing buffer. Usage of SDC-containing buffer as extraction solvent and ethanol-based staining solution enhanced the recovery of intact IgG from SDS-PAGE gels. Recovery of mAbs reached more than 86% with 0.2% SD. The heterogeneities, especially N-glycan variants in the recovered mAb therapeutics, were clearly determined by intact mass analysis. We believe that the study is important in pharmaceuticals‧ perspective since orthogonal combination of gel electrophoresis and intact mass analysis should be pivotal role for rapid and precise characterization of mAbs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. [Analysis on willingness to pay for HIV antibody saliva rapid test and related factors].

    PubMed

    Li, Junjie; Huo, Junli; Cui, Wenqing; Zhang, Xiujie; Hu, Yi; Su, Xingfang; Zhang, Wanyue; Li, Youfang; Shi, Yuhua; Jia, Manhong

    2015-02-01

    To understand the willingness to pay for HIV antibody saliva rapid test and its influential factors among people seeking counsel and HIV test, STD clinic patients, university students, migrant people, female sex workers (FSWs), men who have sex with men (MSM) and injecting drug users (IDUs). An anonymous questionnaire survey was conducted among 511 subjects in the 7 groups selected by different sampling methods, and 509 valid questionnaires were collected. The majority of subjects were males (54.8%) and aged 20-29 years (41.5%). Among the subjects, 60.3% had education level of high school or above, 55.4% were unmarried, 37.3% were unemployed, 73.3% had monthly expenditure <2 000 Yuan RMB, 44.2% had received HIV test, 28.3% knew HIV saliva test, 21.0% were willing to receive HIV saliva test, 2.0% had received HIV saliva test, only 1.0% had bought HIV test kit for self-test, and 84.1% were willing to pay for HIV antibody saliva rapid test. Univariate logistic regression analysis indicated that subject group, age, education level, employment status, monthly expenditure level, HIV test experience and willingness to receive HIV saliva test were correlated statistically with willingness to pay for HIV antibody saliva rapid test. Multivariate logistic regression analysis showed that subject group and monthly expenditure level were statistically correlated with willingness to pay for HIV antibody saliva rapid test. The willingness to pay for HIV antibody saliva rapid test and acceptable price of HIV antibody saliva rapid test varied in different areas and populations. Different populations may have different willingness to pay for HIV antibody saliva rapid test;the affordability of the test could influence the willingness to pay for the test.

  6. Applications of Response Surface-Based Methods to Noise Analysis in the Conceptual Design of Revolutionary Aircraft

    NASA Technical Reports Server (NTRS)

    Hill, Geoffrey A.; Olson, Erik D.

    2004-01-01

    Due to the growing problem of noise in today's air transportation system, there have arisen needs to incorporate noise considerations in the conceptual design of revolutionary aircraft. Through the use of response surfaces, complex noise models may be converted into polynomial equations for rapid and simplified evaluation. This conversion allows many of the commonly used response surface-based trade space exploration methods to be applied to noise analysis. This methodology is demonstrated using a noise model of a notional 300 passenger Blended-Wing-Body (BWB) transport. Response surfaces are created relating source noise levels of the BWB vehicle to its corresponding FAR-36 certification noise levels and the resulting trade space is explored. Methods demonstrated include: single point analysis, parametric study, an optimization technique for inverse analysis, sensitivity studies, and probabilistic analysis. Extended applications of response surface-based methods in noise analysis are also discussed.

  7. Identification of Brucella spp. isolated from human brucellosis in Malaysia using high-resolution melt (HRM) analysis.

    PubMed

    Mohamed Zahidi, Jama'ayah; Bee Yong, Tay; Hashim, Rohaidah; Mohd Noor, Azura; Hamzah, Siti Hawa; Ahmad, Norazah

    2015-04-01

    Molecular approaches have been investigated to overcome difficulties in identification and differentiation of Brucella spp. using conventional phenotypic methods. In this study, high-resolution melt (HRM) analysis was used for rapid identification and differentiation of members of Brucella genus. A total of 41 Brucella spp. isolates from human brucellosis were subjected to HRM analysis using 4 sets of primers, which identified 40 isolates as Brucella melitensis and 1 as Brucella canis. The technique utilized low DNA concentration and was highly reproducible. The assay is shown to be a useful diagnostic tool, which can rapidly differentiate Brucella up to species level. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Terahertz time-domain attenuated total reflection spectroscopy applied to the rapid discrimination of the botanical origin of honeys

    NASA Astrophysics Data System (ADS)

    Liu, Wen; Zhang, Yuying; Yang, Si; Han, Donghai

    2018-05-01

    A new technique to identify the floral resources of honeys is demanded. Terahertz time-domain attenuated total reflection spectroscopy combined with chemometrics methods was applied to discriminate different categorizes (Medlar honey, Vitex honey, and Acacia honey). Principal component analysis (PCA), cluster analysis (CA) and partial least squares-discriminant analysis (PLS-DA) have been used to find information of the botanical origins of honeys. Spectral range also was discussed to increase the precision of PLS-DA model. The accuracy of 88.46% for validation set was obtained, using PLS-DA model in 0.5-1.5 THz. This work indicated terahertz time-domain attenuated total reflection spectroscopy was an available approach to evaluate the quality of honey rapidly.

  9. A simple and rapid technique for the authentication of the ginseng cultivar, Yunpoong, using an SNP marker in a large sample of ginseng leaves.

    PubMed

    Sun, Hua; Wang, Hong-Tao; Kwon, Woo-Saeng; Kim, Yeon-Ju; In, Jun-Gyo; Yang, Deok-Chun

    2011-11-01

    Yunpoong is an important Korean ginseng (Panax ginseng C. A. Meyer) cultivar, but no molecular marker has been available to identify Yunpoong from other cultivars. In this study, we developed a single nucleotide polymorphism (SNP) marker for Yunpoong based on analysis of expressed sequence tags (ESTs) in an exon region of the glyceraldehyde 3-phosphate dehydrogenase (GAPDH) gene. This SNP marker had high specificity to authenticate Yunpoong in twelve different main ginseng cultivars. For application of the molecular marker, a rapid identification method was established based on the NaOH-Tris method and real-time polymerase chain reaction (PCR) in order to ensure more efficiency in the cultivar selection. The biggest feature of the NaOH-Tris method was that it made the extraction of DNA very simple and rapid in young leaf tissues. We only spent 1 min to extract DNA and directly used it to do PCR. In this report, the conventional DNA extraction method was used to develop molecular marker process, and the NaOH-Tris method was applied in screening large numbers of cultivars. Moreover, the greatest advantage of the real-time PCR compared with traditional PCR, is time saving and high efficiency. Thus, this strategy provides a rapid and reliable method for the specific identification of Yunpoong in a large number of samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Rapid screening of mixed edible oils and gutter oils by matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Ng, Tsz-Tsun; So, Pui-Kin; Zheng, Bo; Yao, Zhong-Ping

    2015-07-16

    Authentication of edible oils is a long-term issue in food safety, and becomes particularly important with the emergence and wide spread of gutter oils in recent years. Due to the very high analytical demand and diversity of gutter oils, a high throughput analytical method and a versatile strategy for authentication of mixed edible oils and gutter oils are highly desirable. In this study, an improved matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) method has been developed for direct analysis of edible oils. This method involved on-target sample loading, automatic data acquisition and simple data processing. MALDI-MS spectra with high quality and high reproducibility have been obtained using this method, and a preliminary spectral database of edible oils has been set up. The authenticity of an edible oil sample can be determined by comparing its MALDI-MS spectrum and principal component analysis (PCA) results with those of its labeled oil in the database. This method is simple and the whole process only takes several minutes for analysis of one oil sample. We demonstrated that the method was sensitive to change in oil compositions and can be used for measuring compositions of mixed oils. The capability of the method for determining mislabeling enables it for rapid screening of gutter oils since fraudulent mislabeling is a common feature of gutter oils. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Aerodynamic and structural studies of joined-wing aircraft

    NASA Technical Reports Server (NTRS)

    Kroo, Ilan; Smith, Stephen; Gallman, John

    1991-01-01

    A method for rapidly evaluating the structural and aerodynamic characteristics of joined-wing aircraft was developed and used to study the fundamental advantages attributed to this concept. The technique involves a rapid turnaround aerodynamic analysis method for computing minimum trimmed drag combined with a simple structural optimization. A variety of joined-wing designs are compared on the basis of trimmed drag, structural weight, and, finally, trimmed drag with fixed structural weight. The range of joined-wing design parameters resulting in best cruise performance is identified. Structural weight savings and net drag reductions are predicted for certain joined-wing configurations compared with conventional cantilever-wing configurations.

  12. Rapid determination of sugar level in snack products using infrared spectroscopy.

    PubMed

    Wang, Ting; Rodriguez-Saona, Luis E

    2012-08-01

    Real-time spectroscopic methods can provide a valuable window into food manufacturing to permit optimization of production rate, quality and safety. There is a need for cutting edge sensor technology directed at improving efficiency, throughput and reliability of critical processes. The aim of the research was to evaluate the feasibility of infrared systems combined with chemometric analysis to develop rapid methods for determination of sugars in cereal products. Samples were ground and spectra were collected using a mid-infrared (MIR) spectrometer equipped with a triple-bounce ZnSe MIRacle attenuated total reflectance accessory or Fourier transform near infrared (NIR) system equipped with a diffuse reflection-integrating sphere. Sugar contents were determined using a reference HPLC method. Partial least squares regression (PLSR) was used to create cross-validated calibration models. The predictability of the models was evaluated on an independent set of samples and compared with reference techniques. MIR and NIR spectra showed characteristic absorption bands for sugars, and generated excellent PLSR models (sucrose: SEP < 1.7% and r > 0.96). Multivariate models accurately and precisely predicted sugar level in snacks allowing for rapid analysis. This simple technique allows for reliable prediction of quality parameters, and automation enabling food manufacturers for early corrective actions that will ultimately save time and money while establishing a uniform quality. The U.S. snack food industry generates billions of dollars in revenue each year and vibrational spectroscopic methods combined with pattern recognition analysis could permit optimization of production rate, quality, and safety of many food products. This research showed that infrared spectroscopy is a powerful technique for near real-time (approximately 1 min) assessment of sugar content in various cereal products. © 2012 Institute of Food Technologists®

  13. Urbanization and Land Use Changes in Peri-Urban Area using Spatial Analysis Methods (Case Study: Ciawi Urban Areas, Bogor Regency)

    NASA Astrophysics Data System (ADS)

    Cahya, D. L.; Martini, E.; Kasikoen, K. M.

    2018-02-01

    Urbanization is shown by the increasing percentage of the population in urban areas. In Indonesia, the percentage of urban population increased dramatically form 17.42% (1971) to 42.15% (2010). This resulted in increased demand for housing. Limited land in the city area push residents looking for an alternative location of his residence to the peri-urban areas. It is accompanied by a process of land conversion from green area into built-up area. Continuous land conversion in peri-urban area is becoming increasingly widespread. Bogor Regency as part of the Jakarta Metropolitan Area is experiencing rapid development. This regency has been experienced land-use change very rapidly from agricultural areas into urban built up areas. Aim of this research is to analyze the effect of urbanization on land use changes in peri-urban areas using spatial analysis methods. This research used case study of Ciawi Urban Area that experiencing rapid development. Method of this research is using descriptive quantitative approach. Data used in this research is primary data (field survey) and secondary data (maps). To analyze land use change is using Geographic Information System (GIS) as spatial analysis methods. The effect of urbanization on land use changes in Ciawi Urban Area from year 2013 to 2015 is significant. The reduction of farm land is around -4.00% and wetland is around - 2.51%. The increasing area for hotel/villa/resort is around 3.10%. Based on this research, local government (Bogor Regency) should be alert to the land use changes that does not comply with the land use plan and also consistently apply the spatial planning.

  14. Evaluation of Fourier transform infrared (FT-IR) spectroscopy and chemometrics as a rapid approach for sub-typing Escherichia coli O157:H7 isolates.

    PubMed

    Davis, R; Paoli, G; Mauer, L J

    2012-09-01

    The importance of tracking outbreaks of foodborne illness and the emergence of new virulent subtypes of foodborne pathogens have created the need for rapid and reliable sub-typing methods for Escherichia coli O157:H7. Fourier transform infrared (FT-IR) spectroscopy coupled with multivariate statistical analyses was used for sub-typing 30 strains of E. coli O157:H7 that had previously been typed by multilocus variable number tandem repeat analysis (MLVA) and pulsed field gel electrophoresis (PFGE). Hierarchical cluster analysis (HCA) and canonical variate analysis (CVA) of the FT-IR spectra resulted in the clustering of the same or similar MLVA types and separation of different MLVA types of E. coli O157:H7. The developed FT-IR method showed better discriminatory power than PFGE in sub-typing E. coli O157:H7. Results also indicated the spectral relatedness between different outbreak strains. However, the grouping of some strains was not in complete agreement with the clustering based on PFGE and MLVA. Additionally, HCA of the spectra differentiated the strains into 30 sub-clusters, indicating the high specificity and suitability of the method for strain level identification. Strains were also classified (97% correct) based on the type of Shiga toxin present using CVA of the spectra. This study demonstrated that FT-IR spectroscopy is suitable for rapid (≤16 h) and economical sub-typing of E. coli O157:H7 with comparable accuracy to MLVA typing. This is the first report of using an FT-IR-based method for sub-typing E. coli O157:H7. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. An analysis code for the Rapid Engineering Estimation of Momentum and Energy Losses (REMEL)

    NASA Technical Reports Server (NTRS)

    Dechant, Lawrence J.

    1994-01-01

    Nonideal behavior has traditionally been modeled by defining efficiency (a comparison between actual and isentropic processes), and subsequent specification by empirical or heuristic methods. With the increasing complexity of aeropropulsion system designs, the reliability of these more traditional methods is uncertain. Computational fluid dynamics (CFD) and experimental methods can provide this information but are expensive in terms of human resources, cost, and time. This report discusses an alternative to empirical and CFD methods by applying classical analytical techniques and a simplified flow model to provide rapid engineering estimates of these losses based on steady, quasi-one-dimensional governing equations including viscous and heat transfer terms (estimated by Reynold's analogy). A preliminary verification of REMEL has been compared with full Navier-Stokes (FNS) and CFD boundary layer computations for several high-speed inlet and forebody designs. Current methods compare quite well with more complex method results and solutions compare very well with simple degenerate and asymptotic results such as Fanno flow, isentropic variable area flow, and a newly developed, combined variable area duct with friction flow solution. These solution comparisons may offer an alternative to transitional and CFD-intense methods for the rapid estimation of viscous and heat transfer losses in aeropropulsion systems.

  16. Rapid discrimination of bergamot essential oil by paper spray mass spectrometry and chemometric analysis.

    PubMed

    Taverna, Domenico; Di Donna, Leonardo; Mazzotti, Fabio; Tagarelli, Antonio; Napoli, Anna; Furia, Emilia; Sindona, Giovanni

    2016-09-01

    A novel approach for the rapid discrimination of bergamot essential oil from other citrus fruits oils is presented. The method was developed using paper spray mass spectrometry (PS-MS) allowing for a rapid molecular profiling coupled with a statistic tool for a precise and reliable discrimination between the bergamot complex matrix and other similar matrices, commonly used for its reconstitution. Ambient mass spectrometry possesses the ability to record mass spectra of ordinary samples, in their native environment, without sample preparation or pre-separation by creating ions outside the instrument. The present study reports a PS-MS method for the determination of oxygen heterocyclic compounds such as furocoumarins, psoralens and flavonoids present in the non-volatile fraction of citrus fruits essential oils followed by chemometric analysis. The volatile fraction of Bergamot is one of the most known and fashionable natural products, which found applications in flavoring industry as ingredient in beverages and flavored foodstuff. The development of the presented method employed bergamot, sweet orange, orange, cedar, grapefruit and mandarin essential oils. PS-MS measurements were carried out in full scan mode for a total run time of 2 min. The capability of PS-MS profiling to act as marker for the classification of bergamot essential oils was evaluated by using multivariate statistical analysis. Two pattern recognition techniques, linear discriminant analysis and soft independent modeling of class analogy, were applied to MS data. The cross-validation procedure has shown excellent results in terms of the prediction ability because both models have correctly classified all samples for each category. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. A sensitive and innovative detection method for rapid C-reactive proteins analysis based on a micro-fluxgate sensor system

    PubMed Central

    Yang, Zhen; Zhi, Shaotao; Feng, Zhu; Lei, Chong; Zhou, Yong

    2018-01-01

    A sensitive and innovative assay system based on a micro-MEMS-fluxgate sensor and immunomagnetic beads-labels was developed for the rapid analysis of C-reactive proteins (CRP). The fluxgate sensor presented in this study was fabricated through standard micro-electro-mechanical system technology. A multi-loop magnetic core made of Fe-based amorphous ribbon was employed as the sensing element, and 3-D solenoid copper coils were used to control the sensing core. Antibody-conjugated immunomagnetic microbeads were strategically utilized as signal tags to label the CRP via the specific conjugation of CRP to polyclonal CRP antibodies. Separate Au film substrates were applied as immunoplatforms to immobilize CRP-beads labels through classical sandwich assays. Detection and quantification of the CRP at different concentrations were implemented by detecting the stray field of CRP labeled magnetic beads using the newly-developed micro-fluxgate sensor. The resulting system exhibited the required sensitivity, stability, reproducibility, and selectivity. A detection limit as low as 0.002 μg/mL CRP with a linearity range from 0.002 μg/mL to 10 μg/mL was achieved, and this suggested that the proposed biosystem possesses high sensitivity. In addition to the extremely low detection limit, the proposed method can be easily manipulated and possesses a quick response time. The response time of our sensor was less than 5 s, and the entire detection period for CRP analysis can be completed in less than 30 min using the current method. Given the detection performance and other advantages such as miniaturization, excellent stability and specificity, the proposed biosensor can be considered as a potential candidate for the rapid analysis of CRP, especially for point-of-care platforms. PMID:29601593

  18. hsp65 PCR-restriction analysis (PRA) with capillary electrophoresis in comparison to three other methods for identification of Mycobacterium species.

    PubMed

    Sajduda, Anna; Martin, Anandi; Portaels, Françoise; Palomino, Juan Carlos

    2010-02-01

    We developed a scheme for rapid identification of Mycobacterium species using an automated fluorescence capillary electrophoresis instrument. A 441-bp region of the hsp65 gene was examined using PCR-restriction analysis (PRA). The assay was initially evaluated on 38 reference strains. The observed sizes of restriction fragments were consistently smaller than the real sizes for each of the species as deduced from the sequence analysis (mean variance=7bp). Nevertheless, the obtained PRA patterns were highly reproducible and resulted in correct species identifications. A blind test was then successfully performed on 64 test isolates previously characterized by conventional biochemical methods, a commercial INNO-LiPA Mycobacteria assay and/or sequence determination of the 5' end of 16S rRNA gene. A total of 14 of 64 isolates were erroneously identified by conventional methods (78% accuracy). In contrast, PRA performed very well in comparison with the LiPA (89% concordance) and especially with DNA sequencing (93.3% of concordant results). Also, PRA identified seven isolates representing five previously unreported hsp65 alleles. We conclude that hsp65 PRA based on automated capillary electrophoresis is a rapid, simple and reliable method for identification of mycobacteria. Copyright 2010 Elsevier B.V. All rights reserved.

  19. A rapid method for the extraction and analysis of carotenoids and other hydrophobic substances suitable for systems biology studies with photosynthetic bacteria.

    PubMed

    Bóna-Lovász, Judit; Bóna, Aron; Ederer, Michael; Sawodny, Oliver; Ghosh, Robin

    2013-10-11

    A simple, rapid, and inexpensive extraction method for carotenoids and other non-polar compounds present in phototrophic bacteria has been developed. The method, which has been extensively tested on the phototrophic purple non-sulphur bacterium Rhodospirillum rubrum, is suitable for extracting large numbers of samples, which is common in systems biology studies, and yields material suitable for subsequent analysis using HPLC and mass spectroscopy. The procedure is particularly suitable for carotenoids and other terpenoids, including quinones, bacteriochlorophyll a and bacteriopheophytin a, and is also useful for the analysis of polar phospholipids. The extraction procedure requires only a single step extraction with a hexane/methanol/water mixture, followed by HPLC using a Spherisorb C18 column, with a mobile phase consisting of acetone-water and a non-linear gradient of 50%-100% acetone. The method was employed for examining the carotenoid composition observed during microaerophilic growth of R. rubrum strains, and was able to determine 18 carotenoids, 4 isoprenoid-quinones, bacteriochlorophyll a and bacteriopheophytin a as well as four different phosphatidylglycerol species of different acyl chain compositions. The analytical procedure was used to examine the dynamics of carotenoid biosynthesis in the major and minor pathways operating simultaneously in a carotenoid biosynthesis mutant of R. rubrum.

  20. Mapping Between Bus Rapid Transit Shelter and High School Location in Semarang

    NASA Astrophysics Data System (ADS)

    Dewi, D. I. K.; Rakhmatulloh, A. R.; Anggraini, P.

    2018-02-01

    The main users of public bus transport are those who have the goal to work and attend school. But the last few years there has been a decline in the use of public transport for high school students. Partly of the reason are the high use of motorcycle by student and lack of bus stop service range to high school location. This research has aim to increase the use of public transport for school students by mapping Bus Rapid Transit (BRT) shelter and school locations. The research method used are descriptive quantitative with GIs analysis tools and using spatial analysis approach

  1. A disruptive sequencer meets disruptive publishing.

    PubMed

    Loman, Nick; Goodwin, Sarah; Jansen, Hans; Loose, Matt

    2015-01-01

    Nanopore sequencing was recently made available to users in the form of the Oxford Nanopore MinION. Released to users through an early access programme, the MinION is made unique by its tiny form factor and ability to generate very long sequences from single DNA molecules. The platform is undergoing rapid evolution with three distinct nanopore types and five updates to library preparation chemistry in the last 18 months. To keep pace with the rapid evolution of this sequencing platform, and to provide a space where new analysis methods can be openly discussed, we present a new F1000Research channel devoted to updates to and analysis of nanopore sequence data.

  2. Rapid automatic keyword extraction for information retrieval and analysis

    DOEpatents

    Rose, Stuart J [Richland, WA; Cowley,; E, Wendy [Richland, WA; Crow, Vernon L [Richland, WA; Cramer, Nicholas O [Richland, WA

    2012-03-06

    Methods and systems for rapid automatic keyword extraction for information retrieval and analysis. Embodiments can include parsing words in an individual document by delimiters, stop words, or both in order to identify candidate keywords. Word scores for each word within the candidate keywords are then calculated based on a function of co-occurrence degree, co-occurrence frequency, or both. Based on a function of the word scores for words within the candidate keyword, a keyword score is calculated for each of the candidate keywords. A portion of the candidate keywords are then extracted as keywords based, at least in part, on the candidate keywords having the highest keyword scores.

  3. Rapid detection of milk adulteration using intact protein flow injection mass spectrometric fingerprints combined with chemometrics.

    PubMed

    Du, Lijuan; Lu, Weiying; Cai, Zhenzhen Julia; Bao, Lei; Hartmann, Christoph; Gao, Boyan; Yu, Liangli Lucy

    2018-02-01

    Flow injection mass spectrometry (FIMS) combined with chemometrics was evaluated for rapidly detecting economically motivated adulteration (EMA) of milk. Twenty-two pure milk and thirty-five counterparts adulterated with soybean, pea, and whey protein isolates at 0.5, 1, 3, 5, and 10% (w/w) levels were analyzed. The principal component analysis (PCA), partial least-squares-discriminant analysis (PLS-DA), and support vector machine (SVM) classification models indicated that the adulterated milks could successfully be classified from the pure milks. FIMS combined with chemometrics might be an effective method to detect possible EMA in milk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Rapid screening of abused drugs by direct analysis in real time (DART) coupled to time-of-flight mass spectrometry (TOF-MS) combined with ion mobility spectrometry (IMS).

    PubMed

    Lian, Ru; Wu, Zhongping; Lv, Xiaobao; Rao, Yulan; Li, Haiyang; Li, Jinghua; Wang, Rong; Ni, Chunfang; Zhang, Yurong

    2017-10-01

    Increasing in cases involving drugs of abuse leads to heavy burden for law enforcement agencies, exacerbating demand for rapid screening technique. In this study, atmospheric pressure ionization technologies including direct analysis in real time (DART) ion source coupled to a time-of-flight mass spectrometer (DART-TOF-MS)as well asdopant-assisted positive photoionization ion mobility spectrometry (DAPP-IMS) without radioactivity were utilized together as the powerful analytical tool for the rapid screening and identification of 53 abused drugs.The limits of detection (LOD) were 0.05-2μg/mL when using DART-TOF-MS and 0.02-2μg when using DAPP-IMS which could satisfy the actual requirement in forensic science laboratory. The advantages of this method included fast response, high-throughput potential, high specificity, and minimal sample preparation. A screening library of reduced mobility (K 0 ), accurate mass of informative precursor ion ([M+H] + ) and fragment ions was established respectively by employing a bench-top DAPP-IMS and TOF-MS in-source collision induced dissociation (CID) mode. Then the standardized screening procedure was developed with criteria for the confirmation of positive result. A total of 50 seized drug samples provided by local forensic laboratory we reanalyzed to testify the utility of the method. This study suggests that a method combing DART-TOF-MS and DAPP-IMS is promising for the rapid screening and identification of abused drugs with minimal sample preparation and absence of chromatography. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Rapid identification of regulated organic chemical compounds in toys using ambient ionization and a miniature mass spectrometry system.

    PubMed

    Guo, Xiangyu; Bai, Hua; Lv, Yueguang; Xi, Guangcheng; Li, Junfang; Ma, Xiaoxiao; Ren, Yue; Ouyang, Zheng; Ma, Qiang

    2018-04-01

    Rapid, on-site analysis was achieved through significantly simplified operation procedures for a wide variety of toy samples (crayon, temporary tattoo sticker, finger paint, modeling clay, and bubble solution) using a miniature mass spectrometry system with ambient ionization capability. The labor-intensive analytical protocols involving sample workup and chemical separation, traditionally required for MS-based analysis, were replaced by direct sampling analysis using ambient ionization methods. A Mini β ion trap miniature mass spectrometer was coupled with versatile ambient ionization methods, e.g. paper spray, extraction spray and slug-flow microextraction nanoESI for direct identification of prohibited colorants, carcinogenic primary aromatic amines, allergenic fragrances, preservatives and plasticizers from raw toy samples. The use of paper substrates coated with Co 3 O 4 nanoparticles allowed a great increase in sensitivity for paper spray. Limits of detection as low as 5μgkg -1 were obtained for target analytes. The methods being developed based on the integration of ambient ionization with miniature mass spectrometer represent alternatives to current in-lab MS analysis operation, and would enable fast, outside-the-lab screening of toy products to ensure children's safety and health. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A rapid miniaturized residue analytical method for the determination of zoxamide and its two acid metabolites in ginseng roots using UPLC-MS/MS.

    PubMed

    Podhorniak, Lynda V

    2014-04-30

    A miniaturized residue method was developed for the analysis of the fungicide zoxamide and its metabolites in dried ginseng root. The zoxamide metabolites, 3,5-dichloro-1,4-benzenedicarboxylic acid (DCBC) and 3,5-dichloro-4-hydroxymethylbenzoic acid (DCHB), are small acid molecules that have not been previously extracted from the ginseng matrix with common multiresidue methods. The presented extraction method effectively and rapidly recovers both the zoxamide parent compound and its acid metabolites from fortified ginseng root. The metabolites are extracted with an alkaline glycine buffer and the aqueous ginseng mixture is partitioned with ethyl acetate. In addition, this method avoids the use of derivatization of the small acid molecules by using UPLC-MS/MS instrumental analysis. In a quantitative validation of the analytical method at three levels for zoxamide (0.007 (LOD), 0.02 (LOQ), and 0.2 mg/kg) and four levels (0.07 (LOD), 0.2 (LOQ), and 0.6 and 6 mg/kg) for both metabolites, acceptable method performances were achieved with recoveries ranging from 86 to 107% (at levels of LOQ and 3×, 10×, and 30× the LOQ) with <20% RSD for the three analytes in accordance with international guidelines.1.

  7. Strain, biochemistry, and cultivation-dependent measurement variability of algal biomass composition.

    PubMed

    Laurens, Lieve M L; Van Wychen, Stefanie; McAllister, Jordan P; Arrowsmith, Sarah; Dempster, Thomas A; McGowen, John; Pienkos, Philip T

    2014-05-01

    Accurate compositional analysis in biofuel feedstocks is imperative; the yields of individual components can define the economics of an entire process. In the nascent industry of algal biofuels and bioproducts, analytical methods that have been deemed acceptable for decades are suddenly critical for commercialization. We tackled the question of how the strain and biochemical makeup of algal cells affect chemical measurements. We selected a set of six procedures (two each for lipids, protein, and carbohydrates): three rapid fingerprinting methods and three advanced chromatography-based methods. All methods were used to measure the composition of 100 samples from three strains: Scenedesmus sp., Chlorella sp., and Nannochloropsis sp. The data presented point not only to species-specific discrepancies but also to cell biochemistry-related discrepancies. There are cases where two respective methods agree but the differences are often significant with over- or underestimation of up to 90%, likely due to chemical interferences with the rapid spectrophotometric measurements. We provide background on the chemistry of interfering reactions for the fingerprinting methods and conclude that for accurate compositional analysis of algae and process and mass balance closure, emphasis should be placed on unambiguous characterization using methods where individual components are measured independently. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Rapid simultaneous determination of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, and 3,4-methylenedioxyethylamphetamine in urine by solid-phase extraction and GC-MS: a method optimized for high-volume laboratories.

    PubMed

    Stout, Peter R; Horn, Carl K; Klette, Kevin L

    2002-01-01

    To facilitate analysis of high sample volumes, an extraction, derivatization and gas chromatographic-mass spectrometric analysis method was developed to simultaneously determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxyamphetamine (MDA) 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA) in urine. This method utilized a positive-pressure manifold cation-exchange polymer-based solid-phase extraction followed by elution directly into automated liquid sampler (ALS) vials. Rapid derivatization was accomplished using heptafluorobutyric anhydride (HFBA). Recoveries averaged 90% or greater for each of the compounds. Limits of detection were 62.5 ng/mL (AMP and MDEA), 15.6 ng/mL (MAMP), and 31.3 ng/mL (MDA and MDMA) using a 2-mL sample volume. The method was linear to 5000 ng/mL for all compounds using MDMA-d5 and MAMP-d14 as internal standards. Over 200 human urine samples previously determined to contain the target analytes were analyzed using the method. Excellent agreement was seen with previous quantitations. The method was challenged with 75 potentially interfering compounds and no interferences were seen. These interfering compounds included ephedrine, pseudoephedrine, phenylpropanolamine, and phenethylamine. The method resulted in dramatic reductions in processing time and waste production.

  9. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    PubMed Central

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  10. Analysis of lignans in Magnoliae Flos by turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai

    2016-04-01

    In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Crux: Rapid Open Source Protein Tandem Mass Spectrometry Analysis

    PubMed Central

    2015-01-01

    Efficiently and accurately analyzing big protein tandem mass spectrometry data sets requires robust software that incorporates state-of-the-art computational, machine learning, and statistical methods. The Crux mass spectrometry analysis software toolkit (http://cruxtoolkit.sourceforge.net) is an open source project that aims to provide users with a cross-platform suite of analysis tools for interpreting protein mass spectrometry data. PMID:25182276

  12. Evaluation of the disintegration time of rapidly disintegrating tablets via a novel method utilizing a CCD camera.

    PubMed

    Morita, Yutaka; Tsushima, Yuki; Yasui, Masanobu; Termoz, Ryoji; Ajioka, Junko; Takayama, Kozo

    2002-09-01

    Many kinds of rapidly disintegrating or oral disintegrating tablets (RDT) have been developed to improve the ease of tablet administration, especially for elderly and pediatric patients. In these cases, knowledge regarding disintegration behavior appears important with respect to the development of such a novel tablet. Ordinary disintegration testing, such as the Japanese Pharmacopoeia (JP) method, faces limitations with respect to the evaluation of rapid disintegration due to strong agitation. Therefore, we have developed a novel apparatus and method to determine the dissolution of the RDT. The novel device consists of a disintegrating bath and CCD camera interfaced with a personal computer equipped with motion capture and image analysis software. A newly developed RDT containing various types of binder was evaluated with this protocol. In this method, disintegration occurs in a mildly agitated medium, which allows differentiation of minor distinctions among RDTs of different formulations. Simultaneously, we were also able to detect qualitative information, i.e., morphological changes in the tablet during disintegration. This method is useful for the evaluation of the disintegration of RDT during pharmaceutical development, and also for quality control during production.

  13. Simultaneous quantitation of chloroquine and primaquine by UPLC-DAD and comparison with a HPLC-DAD method.

    PubMed

    Miranda, Tiago A; Silva, Pedro H R; Pianetti, Gerson A; César, Isabela C

    2015-01-28

    Chloroquine and primaquine are the first-line treatment recommended by World Health Organization for malaria caused by Plasmodium vivax. Since the problem of counterfeit or substandard anti-malarials is well established all over the world, the development of rapid and reliable methods for quality control analysis of these drugs is essential. Thus, the aim of this study was to develop and validate a novel UPLC-DAD method for simultaneously quantifying chloroquine and primaquine in tablet formulations. The UPLC separation was carried out using a Hypersil C18 column (50 × 2.1 mm id; 1.9 μm particle size) and a mobile phase composed of acetonitrile (A) and 0.1% aqueous triethylamine, pH 3.0 adjusted with phosphoric acid (B), at a flow rate 0.6 mL/min. Gradient elution was employed. UV detection was performed at 260 nm. UPLC method was fully validated and the results were compared to a conventional HPLC-DAD method for the analysis of chloroquine and primaquine in tablet formulations. UPLC method was shown to be linear (r2 > 0.99), precise (CV < 2.0%), accurate (recovery rates from 98.11 to 99.83%), specific, and robust. No significant differences were observed between the chloroquine and primaquine contents obtained by UPLC and HPLC methods. However, UPLC method promoted faster analyses, better chromatographic performance and lower solvent consumption. The developed UPLC method was shown to be a rapid and suitable technique to quantify chloroquine and primaquine in pharmaceutical preparations and may be successfully employed for quality control analysis.

  14. Ergonomic Evaluation of Dental Professionals as Determined by Rapid Entire Body Assessment Method in 2014

    PubMed Central

    Jahanimoghadam, Fatemeh; Horri, Azadeh; Hasheminejad, Naimeh; Hashemi Nejad, Naser; Baneshi, Mohammad Reza

    2018-01-01

    Statement of the Problem: In dentistry, incorrect working posture is the most important cause of musculoskeletal disorders. Purpose: The aim of this research was to evaluate the work postures of general dentists and specialists using rapid entire body assessment (REBA) method. Materials and Method: In this cross-sectional study, work postures were assessed in 90 dentists by employing REBA method. Stratified sampling method was used. Data were analyzed by analysis of variance (ANOVA), Independent t-test and Pearson’s correlation test in SPSS 19. Results: The results showed that work postures of 90% of dentists were at moderate- to high-risk levels. Among the specialists, periodontists, pedodontists and oral and maxillofacial surgeons had the worst body postures. Conclusion: In general, dentists’ working postures need improvement and consequently, a more comprehensive ergonomic training and promotion is required in dentistry curriculum at Universities. PMID:29854890

  15. Mathematic models for a ray tracing method and its applications in wireless optical communications.

    PubMed

    Zhang, Minglun; Zhang, Yangan; Yuan, Xueguang; Zhang, Jinnan

    2010-08-16

    This paper presents a new ray tracing method, which contains a whole set of mathematic models, and its validity is verified by simulations. In addition, both theoretical analysis and simulation results show that the computational complexity of the method is much lower than that of previous ones. Therefore, the method can be used to rapidly calculate the impulse response of wireless optical channels for complicated systems.

  16. A Simple and Rapid UPLC-PDA Method for Quality Control of Nardostachys jatamansi.

    PubMed

    Zhang, Weize; Nan, Guo; Wu, Hong-Hua; Jiang, Miaomiao; Li, Tian-Xiang; Wang, Meng; Gao, Xiu-Mei; Zhu, Yan; Song, Yun Seon; Wang, Jiaming; Xu, Yan-Tong

    2018-05-01

    Nardostachys jatamansi is a well-documented herbal agent used to treat digestive and neuropsychiatric disorders in oriental medicinal systems. However, few simple, rapid, and comprehensive methods were reported for quality assessment and control of N. jatamansi . Herein, a UPLC with photodiode array detection method was developed for both fingerprint investigation of N. jatamansi and simultaneous quantitative analysis of the six serotonin transporter modulatory constituents in N. jatamansi . For chromatographic fingerprinting, 24 common peaks were selected as characteristic peaks to assess the consistency of N. jatamansi samples from different retail sources. Six of the common peaks (5, 7, 12: , and 16:  - 18: ) were identified as desoxo-narchinol A, buddleoside, isonardosinone, nardosinone, kanshone H, and (-)-aristolone, respectively, by phytochemical investigation. Five of the six compounds significantly either enhanced or inhibited serotonin transporter activity, while (-)-aristolone (18: ) didn't show any serotonin transporter activity. In quantitative analysis, the six compounds showed good linearity ( r  > 0.999) within test ranges. The precision, expressed as relative standard deviation, was in the range of 0.25 - 2.77%, and the recovery of the method was in the range of 92 - 105%. The UPLC-photodiode array detection-based fingerprint analysis and quantitative methods reported here could be used for routine quality control of N. jatamansi . Georg Thieme Verlag KG Stuttgart · New York.

  17. Rapid and precise measurement of serum branched-chain and aromatic amino acids by isotope dilution liquid chromatography tandem mass spectrometry.

    PubMed

    Yang, Ruiyue; Dong, Jun; Guo, Hanbang; Li, Hongxia; Wang, Shu; Zhao, Haijian; Zhou, Weiyan; Yu, Songlin; Wang, Mo; Chen, Wenxiang

    2013-01-01

    Serum branched-chain and aromatic amino acids (BCAAs and AAAs) have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standards and the amino acids were extracted with acetonitrile, followed by analysis using LC/MS/MS. The LC separation was performed on a reversed-phase C18 column, and the MS/MS detection was performed via the positive electronic spray ionization in multiple reaction monitoring mode. Specific analysis of the amino acids was achieved within 2 min. Intra-run and total CVs for the amino acids were less than 2% and 4%, respectively, and the analytical recoveries ranged from 99.6 to 103.6%. A rapid and precise method for the measurement of serum BCAAs and AAAs was developed and may serve as a quick tool for screening serum BCAAs and AAAs in studies assessing diabetes risk.

  18. Effect of genetic algorithm as a variable selection method on different chemometric models applied for the analysis of binary mixture of amoxicillin and flucloxacillin: A comparative study

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; Nassar, Mohammed W. I.; El-Zeiny, Mohamed B.; Serag, Ahmed

    2016-03-01

    Different chemometric models were applied for the quantitative analysis of amoxicillin (AMX), and flucloxacillin (FLX) in their binary mixtures, namely, partial least squares (PLS), spectral residual augmented classical least squares (SRACLS), concentration residual augmented classical least squares (CRACLS) and artificial neural networks (ANNs). All methods were applied with and without variable selection procedure (genetic algorithm GA). The methods were used for the quantitative analysis of the drugs in laboratory prepared mixtures and real market sample via handling the UV spectral data. Robust and simpler models were obtained by applying GA. The proposed methods were found to be rapid, simple and required no preliminary separation steps.

  19. Rapid and sensitive detection of synthetic cannabinoids AMB-FUBINACA and α-PVP using surface enhanced Raman scattering (SERS)

    NASA Astrophysics Data System (ADS)

    Islam, Syed K.; Cheng, Yin Pak; Birke, Ronald L.; Green, Omar; Kubic, Thomas; Lombardi, John R.

    2018-04-01

    The application of surface enhanced Raman scattering (SERS) has been reported as a fast and sensitive analytical method in the trace detection of the two most commonly known synthetic cannabinoids AMB-FUBINACA and alpha-pyrrolidinovalerophenone (α-PVP). FUBINACA and α-PVP are two of the most dangerous synthetic cannabinoids which have been reported to cause numerous deaths in the United States. While instruments such as GC-MS, LC-MS have been traditionally recognized as analytical tools for the detection of these synthetic drugs, SERS has been recently gaining ground in the analysis of these synthetic drugs due to its sensitivity in trace analysis and its effectiveness as a rapid method of detection. This present study shows the limit of detection of a concentration as low as picomolar for AMB-FUBINACA while for α-PVP, the limit of detection is in nanomolar concentration using SERS.

  20. Classification of narcotics in solid mixtures using principal component analysis and Raman spectroscopy.

    PubMed

    Ryder, Alan G

    2002-03-01

    Eighty-five solid samples consisting of illegal narcotics diluted with several different materials were analyzed by near-infrared (785 nm excitation) Raman spectroscopy. Principal Component Analysis (PCA) was employed to classify the samples according to narcotic type. The best sample discrimination was obtained by using the first derivative of the Raman spectra. Furthermore, restricting the spectral variables for PCA to 2 or 3% of the original spectral data according to the most intense peaks in the Raman spectrum of the pure narcotic resulted in a rapid discrimination method for classifying samples according to narcotic type. This method allows for the easy discrimination between cocaine, heroin, and MDMA mixtures even when the Raman spectra are complex or very similar. This approach of restricting the spectral variables also decreases the computational time by a factor of 30 (compared to the complete spectrum), making the methodology attractive for rapid automatic classification and identification of suspect materials.

  1. Rapid Quantification of Melamine in Different Brands/Types of Milk Powders Using Standard Addition Net Analyte Signal and Near-Infrared Spectroscopy

    PubMed Central

    2016-01-01

    Multivariate calibration (MVC) and near-infrared (NIR) spectroscopy have demonstrated potential for rapid analysis of melamine in various dairy products. However, the practical application of ordinary MVC can be largely restricted because the prediction of a new sample from an uncalibrated batch would be subject to a significant bias due to matrix effect. In this study, the feasibility of using NIR spectroscopy and the standard addition (SA) net analyte signal (NAS) method (SANAS) for rapid quantification of melamine in different brands/types of milk powders was investigated. In SANAS, the NAS vector of melamine in an unknown sample as well as in a series of samples added with melamine standards was calculated and then the Euclidean norms of series standards were used to build a straightforward univariate regression model. The analysis results of 10 different brands/types of milk powders with melamine levels 0~0.12% (w/w) indicate that SANAS obtained accurate results with the root mean squared error of prediction (RMSEP) values ranging from 0.0012 to 0.0029. An additional advantage of NAS is to visualize and control the possible unwanted variations during standard addition. The proposed method will provide a practically useful tool for rapid and nondestructive quantification of melamine in different brands/types of milk powders. PMID:27525154

  2. Rapid discrimination between buffalo and cow milk and detection of adulteration of buffalo milk with cow milk using synchronous fluorescence spectroscopy in combination with multivariate methods.

    PubMed

    Durakli Velioglu, Serap; Ercioglu, Elif; Boyaci, Ismail Hakki

    2017-05-01

    This research paper describes the potential of synchronous fluorescence (SF) spectroscopy for authentication of buffalo milk, a favourable raw material in the production of some premium dairy products. Buffalo milk is subjected to fraudulent activities like many other high priced foodstuffs. The current methods widely used for the detection of adulteration of buffalo milk have various disadvantages making them unattractive for routine analysis. Thus, the aim of the present study was to assess the potential of SF spectroscopy in combination with multivariate methods for rapid discrimination between buffalo and cow milk and detection of the adulteration of buffalo milk with cow milk. SF spectra of cow and buffalo milk samples were recorded between 400-550 nm excitation range with Δλ of 10-100 nm, in steps of 10 nm. The data obtained for ∆λ = 10 nm were utilised to classify the samples using principal component analysis (PCA), and detect the adulteration level of buffalo milk with cow milk using partial least square (PLS) methods. Successful discrimination of samples and detection of adulteration of buffalo milk with limit of detection value (LOD) of 6% are achieved with the models having root mean square error of calibration (RMSEC) and the root mean square error of cross-validation (RMSECV) and root mean square error of prediction (RMSEP) values of 2, 7, and 4%, respectively. The results reveal the potential of SF spectroscopy for rapid authentication of buffalo milk.

  3. Characterizing the Frequency and Elevation of Rapid Drainage Events in West Greenland

    NASA Astrophysics Data System (ADS)

    Cooley, S.; Christoffersen, P.

    2016-12-01

    Rapid drainage of supraglacial lakes on the Greenland Ice Sheet is critical for the establishment of surface-to-bed hydrologic connections and the subsequent transfer of water from surface to bed. Yet, estimates of the number and spatial distribution of rapidly draining lakes vary widely due to limitations in the temporal frequency of image collection and obscureness by cloud. So far, no study has assessed the impact of these observation biases. In this study, we examine the frequency and elevation of rapidly draining lakes in central West Greenland, from 68°N to 72.6°N, and we make a robust statistical analysis to estimate more accurately the likelihood of lakes draining rapidly. Using MODIS imagery and a fully automated lake detection method, we map more than 500 supraglacial lakes per year over a 63000 km2 study area from 2000-2015. Through testing four different definitions of rapidly draining lakes from previously published studies, we find that the number of rapidly draining lakes varies from 3% to 38%. Logistic regression between rapid drainage events and image sampling frequency demonstrates that the number of rapid drainage events is strongly dependent on cloud-free observation percentage. We then develop three new drainage criteria and apply an observation bias correction that suggests a true rapid drainage probability between 36% and 45%, considerably higher than previous studies without bias assessment have reported. We find rapid-draining lakes are on average larger and disappear earlier than slow-draining lakes, and we also observe no elevation differences for the lakes detected as rapidly draining. We conclude a) that methodological problems in rapid drainage research caused by observation bias and varying detection methods have obscured large-scale rapid drainage characteristics and b) that the lack of evidence for an elevation limit on rapid drainage suggests surface-to-bed hydrologic connections may continue to propagate inland as climate warms.

  4. Theoretical analysis of incompressible flow through a radial-inlet centrifugal impeller at various weight flows

    NASA Technical Reports Server (NTRS)

    Kramer, James J; Prian, Vasily D; Wu, Chung-Hua

    1956-01-01

    A method for the solution of the incompressible nonviscous flow through a centrifugal impeller, including the inlet region, is presented. Several numerical solutions are obtained for four weight flows through an impeller at one operating speed. These solutions are refined in the leading-edge region. The results are presented in a series of figures showing streamlines and relative velocity contours. A comparison is made with the results obtained by using a rapid approximate method of analysis.

  5. Three-dimensional reconstruction of single-cell chromosome structure using recurrence plots.

    PubMed

    Hirata, Yoshito; Oda, Arisa; Ohta, Kunihiro; Aihara, Kazuyuki

    2016-10-11

    Single-cell analysis of the three-dimensional (3D) chromosome structure can reveal cell-to-cell variability in genome activities. Here, we propose to apply recurrence plots, a mathematical method of nonlinear time series analysis, to reconstruct the 3D chromosome structure of a single cell based on information of chromosomal contacts from genome-wide chromosome conformation capture (Hi-C) data. This recurrence plot-based reconstruction (RPR) method enables rapid reconstruction of a unique structure in single cells, even from incomplete Hi-C information.

  6. Three-dimensional reconstruction of single-cell chromosome structure using recurrence plots

    NASA Astrophysics Data System (ADS)

    Hirata, Yoshito; Oda, Arisa; Ohta, Kunihiro; Aihara, Kazuyuki

    2016-10-01

    Single-cell analysis of the three-dimensional (3D) chromosome structure can reveal cell-to-cell variability in genome activities. Here, we propose to apply recurrence plots, a mathematical method of nonlinear time series analysis, to reconstruct the 3D chromosome structure of a single cell based on information of chromosomal contacts from genome-wide chromosome conformation capture (Hi-C) data. This recurrence plot-based reconstruction (RPR) method enables rapid reconstruction of a unique structure in single cells, even from incomplete Hi-C information.

  7. Computer graphics and cultural heritage, part 2: continuing inspiration for future tools.

    PubMed

    Arnold, David

    2014-01-01

    The availability of large quantities of cultural-heritage data will enable new, previously inconceivable, types of analysis and new applications. Currently, most emerging analysis methods are experimental research. It's likely to take many years before the research matures and provides cultural-heritage professionals with novel research methods that they use routinely. Indeed, we can expect further disruptive technologies to emerge in the foreseeable future and a "steady state" of continuing rapid change. Part 1 can be found at 10.1109/MCG.2014.47.

  8. Organophosphorus pesticide poisonings in humans: determination of residues and metabolites in tissues and urine.

    PubMed

    Lores, E M; Bradway, D E; Moseman, R F

    1978-01-01

    The analyses of four organophosphorus pesticide poisoning cases, three of which resulted in death, are reported. The case histories of the subjects, along with the analysis of tissues, urine, and blood for the levels of pesticides and metabolites are given. The pesticides involved include dicrotophos, chlorpyrifos, malathion, and parathion. The methods of analysis were adapted from previously published methods that provide a very rapid means of identification of organophosphorus pesticides in the tissues or in the blood of poisoned patients.

  9. Determination of rhenium in molybdenite by neutron-activation analysis.

    PubMed

    Terada, K; Yoshimura, Y; Osaki, S; Kiba, T

    1967-01-01

    A neutron-activation method is described for the determination of rhenium in molybdenite. Radiochemical separation by a carrier technique was carried out very rapidly by means of successive liquid-liquid extraction processes. The recovery of rhenium, which was determined by a spectrophotometric method, was about 93%. About 10 samples could be analysed within 6 hr in parallel runs.

  10. Should We Trust Web-Based Studies? A Comparative Analysis of Six Preconceptions about Internet Questionnaires

    ERIC Educational Resources Information Center

    Gosling, Samuel D.; Vazire, Simine; Srivastava, Sanjay; Oliver, John

    2004-01-01

    The rapid growth of the Internet provides a wealth of new research opportunities for psychologists. Internet data collection methods, with a focus on self-report questionnaires from self-selected samples, are evaluated and compared with traditional paper-and-pencil methods. Six preconceptions about Internet samples and data quality are evaluated…

  11. A RAPID METHOD FOR THE EXTRACTION OF FUNGAL DNA FROM ENVIRONMENTAL SAMPLES: EVALUATION IN THE QUANTITATIVE ANALYSIS OF MEMNONIELLA ECHINATA CONIDIA USING REAL TIME DETECTION OF PCR PRODUCTS

    EPA Science Inventory

    New technologies are creating the potential for using nucleic acid sequence detection to perform routine microbiological analyses of environmental samples. Our laboratory has recently reported on the development of a method for the quantitative detection of Stachybotrys chartarum...

  12. Evaluation of Commercial Cell Preparations as Sources of Calibration Standards for Real-Time qPCR Analysis of Enterococci in Recreational Waters

    EPA Science Inventory

    In response to the Beach Act, the U.S. EPA has developed a quantitative PCR (qPCR) method for enterococci that meets requirements for rapid, risk-based water quality assessments of recreational waters. Widespread implementation of this method will require that different laborator...

  13. Rapid fingerprinting of spilled petroleum products using fluorescence spectroscopy coupled with parallel factor and principal component analysis.

    PubMed

    Mirnaghi, Fatemeh S; Soucy, Nicholas; Hollebone, Bruce P; Brown, Carl E

    2018-05-19

    The characterization of spilled petroleum products in an oil spill is necessary for identifying the spill source, selection of clean-up strategies, and evaluating potential environmental and ecological impacts. Existing standard methods for the chemical characterization of spilled oils are time-consuming due to the lengthy sample preparation for analysis. The main objective of this study is the development of a rapid screening method for the fingerprinting of spilled petroleum products using excitation/emission matrix (EEM) fluorescence spectroscopy, thereby delivering a preliminary evaluation of the petroleum products within hours after a spill. In addition, the developed model can be used for monitoring the changes of aromatic compositions of known spilled oils over time. This study involves establishing a fingerprinting model based on the composition of polycyclic and heterocyclic aromatic hydrocarbons (PAH and HAHs, respectively) of 130 petroleum products at different states of evaporative weathering. The screening model was developed using parallel factor analysis (PARAFAC) of a large EEM dataset. The significant fluorescing components for each sample class were determined. After which, through principal component analysis (PCA), the variation of scores of their modeled factors was discriminated based on the different classes of petroleum products. This model was then validated using gas chromatography-mass spectrometry (GC-MS) analysis. The rapid fingerprinting and the identification of unknown and new spilled oils occurs through matching the spilled product with the products of the developed model. Finally, it was shown that HAH compounds in asphaltene and resins contribute to ≥4-ring PAHs compounds in petroleum products. Copyright © 2018. Published by Elsevier Ltd.

  14. [Scenario analysis--a method for long-term planning].

    PubMed

    Stavem, K

    2000-01-10

    Scenarios are known from the film industry, as detailed descriptions of films. This has given name to scenario analysis, a method for long term planning using descriptions of composite future pictures. This article is an introduction to the scenario method. Scenarios describe plausible, not necessarily probable, developments. They focus on problems and questions that decision makers must be aware of and prepare to deal with, and the consequences of alternative decisions. Scenarios are used in corporate and governmental planning, and they can be useful and complementary to traditional planning and extrapolation of past experience. The method is particularly useful in a rapidly changing world with shifting external conditions.

  15. Development of Conductive Polymer Analysis for the Rapid Detection and Identification of Phytopathogenic Microbes

    Treesearch

    A. Dan Wilson; D.G. Lester; C.S. Oberle

    2004-01-01

    Conductive polymer analysis, a type of electronic aroma detection technology, was evaluated for its efficacy in the detection, identification, and discrimination of plant-pathogenic microorganisms on standardized media and in diseased plant tissues. The method is based on the acquisition of a diagnostic electronic fingerprint derived from multisensor responses to...

  16. Web-Based Analysis for Student-Generated Complex Genetic Profiles

    ERIC Educational Resources Information Center

    Kass, David H.; LaRoe, Robert

    2007-01-01

    A simple, rapid method for generating complex genetic profiles using Alu-based markers was recently developed for students primarily at the undergraduate level to learn more about forensics and paternity analysis. On the basis of the Cold Spring Harbor Allele Server, which provides an excellent tool for analyzing a single Alu variant, we present a…

  17. The application of near infrared (NIR) spectroscopy to inorganic preservative-treated wood

    Treesearch

    Chi-Leung So; Stan T. Lebow; Leslie H. Groom; Timothy G. Rials

    2004-01-01

    There is a growing need to find a rapid, inexpensive, and reliable method to distinguish between treated and untreated waste wood. This paper evaluates the ability of near infrared (NIR) spectroscopy with multivariate analysis (MVA) to distinguish preservative types and retentions. It is demonstrated that principal component analysis (PCA) can differentiate lumber...

  18. Methods for improved preconcentrators

    DOEpatents

    Manginell, Ronald P [Albuquerque, NM; Lewis, Patrick R [Albuquerque, NM; Okandan, Murat [Edgewood, NM

    2010-06-01

    The present invention relates generally to chemical analysis (e.g. by gas chromatography), and in particular to a compact chemical preconcentrator formed on a substrate with a heatable sorptive membrane that can be used to accumulate and concentrate one or more chemical species of interest over time and then rapidly release the concentrated chemical species upon demand for chemical analysis.

  19. COMPARISON OF ENTEROCOCCUS MEASUREMENTS IN FRESHWATER AT TWO RECREATIONAL BEACHES BY QUANTITATIVE POLYMERASE CHAIN REACTION AND MEMBRANE FILER CULTURE ANALYSIS

    EPA Science Inventory

    Cell densities of the fecal pollution indicator genus, Enterococcus, were determined by a rapid (2-3 hr) quantitative PCR (QPCR) analysis based method in 100 ml water samples collected from recreational beaches on Lake Michigan and Lake Erie during the summer of 2003. Enumeration...

  20. Analysis Of Volatile Fingerprints: A Rapid Screening Method For Antifungal Agents For Efficacy Against Dermatophytes

    NASA Astrophysics Data System (ADS)

    Naraghi, Kamran; Sahgal, Natasha; Adriaans, Beverley; Barr, Hugh; Magan, Naresh

    2009-05-01

    The potential of using an electronic nose (E. nose) for rapid screening dermatophytes to antifungal agents was studied. In vitro, the 50 and 90% effective concentration (EC) values of five antifungal agents for T. rubrum and T. mentagrophytes were obtained by mycelial growth assays. Then, the qualitative volatile production patterns of the growth responses of these fungi to these values were incorporated into solid medium were analysed after 96-120 hrs incubation at 25° C using headspace analyses. Overall, results, using PCA and CA demonstrated that it is possible to differentiate between various treatments within 96-120 hrs. This study showed that potential exists for using qualitative volatile patterns as a rapid screening method for antifungal agents for microorganism. This approach could also facilitate the monitoring of antimicrobial drug activities and infection control programmes and perhaps drug resistance build up in microbial species.

  1. Rapid determination of ampicillin in bovine milk by liquid chromatography with fluorescence detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ang, C.Y.W.; Luo, Wenhong

    1997-01-01

    A rapid and sensitive liquid chromatographic (LC) method was developed for the determination of ampicillin residues in raw bovine milk, processed skim milk, and pasteurized, homogenized whole milk with vitamin D. Milk samples were deproteinized with trichloroacetic acid (TCA) and acetonictrile. After centrifugation, the clear supernatant was reacted with formaldehyde and TCA under heat. The major fluorescent derivative of ampicillin was then determined by reversed-phase LC with fluorescence detection. Average recoveries of ampicillin fortified at 5, 10, and 20 ppb (ng/mL) were all >85% with coefficients of variation <10%. Limits of detection ranged from 0.31 to 0.51 ppb and limitsmore » of quantitation, from 0.66 to 1.2 ppb. After appropriate validation, this method should be suitable for rapid analysis of milk for ampicillin residues at the tolerance level of 10 ppb. 16 refs., 4 figs., 3 tabs.« less

  2. Assessing direct analysis in real-time-mass spectrometry (DART-MS) for the rapid identification of additives in food packaging.

    PubMed

    Ackerman, L K; Noonan, G O; Begley, T H

    2009-12-01

    The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.

  3. High-Resolution Melt Analysis for Rapid Comparison of Bacterial Community Compositions

    PubMed Central

    Hjelmsø, Mathis Hjort; Hansen, Lars Hestbjerg; Bælum, Jacob; Feld, Louise; Holben, William E.

    2014-01-01

    In the study of bacterial community composition, 16S rRNA gene amplicon sequencing is today among the preferred methods of analysis. The cost of nucleotide sequence analysis, including requisite computational and bioinformatic steps, however, takes up a large part of many research budgets. High-resolution melt (HRM) analysis is the study of the melt behavior of specific PCR products. Here we describe a novel high-throughput approach in which we used HRM analysis targeting the 16S rRNA gene to rapidly screen multiple complex samples for differences in bacterial community composition. We hypothesized that HRM analysis of amplified 16S rRNA genes from a soil ecosystem could be used as a screening tool to identify changes in bacterial community structure. This hypothesis was tested using a soil microcosm setup exposed to a total of six treatments representing different combinations of pesticide and fertilization treatments. The HRM analysis identified a shift in the bacterial community composition in two of the treatments, both including the soil fumigant Basamid GR. These results were confirmed with both denaturing gradient gel electrophoresis (DGGE) analysis and 454-based 16S rRNA gene amplicon sequencing. HRM analysis was shown to be a fast, high-throughput technique that can serve as an effective alternative to gel-based screening methods to monitor microbial community composition. PMID:24610853

  4. Selective and rapid determination of tadalafil and finasteride using solid phase extraction by high performance liquid chromatography and tandem mass spectrometry.

    PubMed

    Pappula, Nagaraju; Kodali, Balaji; Datla, Peda Varma

    2018-04-15

    Highly selective and fast liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for simultaneous determination of tadalafil (TDL) and finasteride (FNS) in human plasma. The method was successfully applied for analysis of TDL and FNS samples in clinical study. The method was validated as per USFDA (United States Food and Drug Administration), EMA (European Medicines Agency), and ANVISA (Agência Nacional de Vigilância Sanitária-Brazil) bio analytical method validation guidelines. Glyburide (GLB) was used as common internal standard (ISTD) for both analytes. The selected multiple reaction monitoring (MRM) transitions for mass spectrometric analysis were m/z 390.2/268.2, m/z 373.3/305.4 and m/z 494.2/369.1 for TDL, FNS and ISTD respectively. The extraction of analytes and ISTD was accomplished by a simple solid phase extraction (SPE) procedure. Rapid analysis time was achieved on Zorbax Eclipse C18 column (50 × 4.6 mm, 5 μm). The calibration ranges for TDL and FNS were 5-800 ng/ml and 0.2-30 ng/ml respectively. The results of precision and accuracy, linearity, recovery and matrix effect of the method are acceptable. The accuracy was in the range of 92.9%-106.4% and method precision was also good; %CV was less than 8.1%. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Development of a rapid 21-plex autosomal STR typing system for forensic applications.

    PubMed

    Yang, Meng; Yin, Caiyong; Lv, Yuexin; Yang, Yaran; Chen, Jing; Yu, Zailiang; Liu, Xu; Xu, Meibo; Chen, Feng; Wu, Huijuan; Yan, Jiangwei

    2016-10-01

    DNA-STR genotyping technology has been widely used in forensic investigations. Even with such success, there is a great need to reduce the analysis time. In this study, we established a new rapid 21-plex STR typing system, including 13 CODIS loci, Penta D, Penta E, D12S391, D2S1338, D6S1043, D19S433, D2S441 and Amelogenin loci. This system could shorten the amplification time to a minimum of 90 min and does not require DNA extraction from the samples. Validation of the typing system complied with the Scientific Working Group on DNA Analysis Methods (SWGDAM) and the Chinese National Standard (GA/T815-2009) guidelines. The results demonstrated that this 21-plex STR typing system was a valuable tool for rapid criminal investigation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Rapid detection of infectious hypodermal and hematopoietic necrosis virus (IHHNV) by real-time, isothermal recombinase polymerase amplification assay.

    PubMed

    Xia, Xiaoming; Yu, Yongxin; Hu, Linghao; Weidmann, Manfred; Pan, Yingjie; Yan, Shuling; Wang, Yongjie

    2015-04-01

    Infectious hypodermal and hematopoietic necrosis virus (IHHNV) causes mortality or runt deformity syndrome in penaeid shrimps and is responsible for significant economic losses in the shrimp aquaculture industry. Here, we describe a novel real-time isothermal recombinase polymerase amplification (RPA) assay developed for IHHNV detection. Using IHHNV plasmid standards and DNA samples from a variety of organisms, we evaluated the ability of the IHHNV-RPA assay to detect IHHNV based on analysis of its sensitivity, specificity, rapidity, and reproducibility. Probit analysis of eight independent experimental replicates indicated satisfactory performance of the RPA assay, which is sufficiently sensitive to detect as few as 4 copies of the IHHNV genome within 7 min at 39 °C with 95 % reliability. Therefore, this rapid RPA method has great potential for applications, either in field use or as a point of care diagnostic technique.

  7. Photoacoustic spectroscopy sample array vessels and photoacoustic spectroscopy methods for using the same

    DOEpatents

    Amonette, James E.; Autrey, S. Thomas; Foster-Mills, Nancy S.

    2006-02-14

    Methods and apparatus for simultaneous or sequential, rapid analysis of multiple samples by photoacoustic spectroscopy are disclosed. Particularly, a photoacoustic spectroscopy sample array vessel including a vessel body having multiple sample cells connected thereto is disclosed. At least one acoustic detector is acoustically positioned near the sample cells. Methods for analyzing the multiple samples in the sample array vessels using photoacoustic spectroscopy are provided.

  8. A method for the specific detection of resident bacteria in brine shrimp larvae.

    PubMed

    Niu, Yufeng; Defoirdt, Tom; Rekecki, Anamaria; De Schryver, Peter; Van den Broeck, Wim; Dong, Shuanglin; Sorgeloos, Patrick; Boon, Nico; Bossier, Peter

    2012-04-01

    In this study, we describe an easy but efficient method to specifically target the intestinal resident microbiota in brine shrimp larvae during DGGE analysis, hereby excluding the interference of both transient (luminal) bacteria and body surface bacteria. This effective technique has several advantages over alternative methods, with respect of ease of use and rapidity. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. EDTA analysis on the Roche MODULAR analyser.

    PubMed

    Davidson, D F

    2007-05-01

    Patient specimens can be subject to subtle interference from cross contamination by liquid-based, potassium-containing EDTA anticoagulant, leading to misinterpretation of results. A rapid method for EDTA analysis to detect such contamination is described. An in-house EDTA assay on the Roche MODULAR analyser was assessed for accuracy and precision by comparison with an adjusted calcium difference measurement (atomic absorption and o-cresolphthalein complexone colorimetry). EDTA method versus adjusted calcium difference showed: slope = 1.038 (95% confidence interval [CI] 0.949-1.131); intercept = 0.073 (95% CI 0.018-0.132) mmol/L; r = 0.914; n = 94. However, inter-assay precision of the calcium difference method was estimated to be poorer (coefficient of variation 24.8% versus 3.4% for the automated colorimetric method at an EDTA concentration of 0.25 mmol/L). Unequivocal contamination was observed at an EDTA concentration of > or =0.2 mmol/L. The automated method showed positive interference from haemolysis and negative interference from oxalate. The method was unaffected by lipaemia (triglycerides <20 mmol/L), icterus (bilirubin <500 micromol/L), glucose (<100 mmol/L), iron (<100 micromol/L), and citrate, phosphate or fluoride (all <2.5 mmol/L). The automated colorimetric assay described is an accurate, precise and rapid (3 min) means of detecting EDTA contamination of unhaemolysed biochemistry specimens.

  10. Rapid analysis of dissolved methane, ethylene, acetylene and ethane using partition coefficients and headspace-gas chromatography.

    PubMed

    Lomond, Jasmine S; Tong, Anthony Z

    2011-01-01

    Analysis of dissolved methane, ethylene, acetylene, and ethane in water is crucial in evaluating anaerobic activity and investigating the sources of hydrocarbon contamination in aquatic environments. A rapid chromatographic method based on phase equilibrium between water and its headspace is developed for these analytes. The new method requires minimal sample preparation and no special apparatus except those associated with gas chromatography. Instead of Henry's Law used in similar previous studies, partition coefficients are used for the first time to calculate concentrations of dissolved hydrocarbon gases, which considerably simplifies the calculation involved. Partition coefficients are determined to be 128, 27.9, 1.28, and 96.3 at 30°C for methane, ethylene, acetylene, and ethane, respectively. It was discovered that the volume ratio of gas-to-liquid phase is critical to the accuracy of the measurements. The method performance can be readily improved by reducing the volume ratio of the two phases. Method validation shows less than 6% variation in accuracy and precision except at low levels of methane where interferences occur in ambient air. Method detection limits are determined to be in the low ng/L range for all analytes. The performance of the method is further tested using environmental samples collected from various sites in Nova Scotia.

  11. Evaluation of a Method for Rapid Detection of Listeria monocytogenes in Dry-Cured Ham Based on Impedanciometry Combined with Chromogenic Agar.

    PubMed

    Labrador, Mirian; Rota, María C; Pérez, Consuelo; Herrera, Antonio; Bayarri, Susana

    2018-05-01

    The food industry is in need of rapid, reliable methodologies for the detection of Listeria monocytogenes in ready-to-eat products, as an alternative to the International Organization of Standardization (ISO) 11290-1 reference method. The aim of this study was to evaluate impedanciometry combined with chromogenic agar culture for the detection of L. monocytogenes in dry-cured ham. The experimental setup consisted in assaying four strains of L. monocytogenes and two strains of Listeria innocua in pure culture. The method was evaluated according to the ISO 16140:2003 standard through a comparative study with the ISO reference method with 119 samples of dry-cured ham. Significant determination coefficients ( R 2 of up to 0.99) for all strains assayed in pure culture were obtained. The comparative study results had 100% accuracy, 100% specificity, and 100% sensitivity. Impedanciometry followed by chromogenic agar culture was capable of detecting 1 CFU/25 g of food. L. monocytogenes was not detected in the 65 commercial samples tested. The method evaluated herein represents a promising alternative for the food industry in its efforts to control L. monocytogenes. Overall analysis time is shorter and the method permits a straightforward analysis of a large number of samples with reliable results.

  12. Inductive interference in rapid transit signaling systems. volume 2. suggested test procedures.

    DOT National Transportation Integrated Search

    1987-03-31

    These suggested test procedures have been prepared in order to develop standard methods of analysis and testing to quantify and resolve issues of electromagnetic compatibility in rail transit operations. Electromagnetic interference, generated by rai...

  13. Compression-based distance (CBD): a simple, rapid, and accurate method for microbiota composition comparison

    PubMed Central

    2013-01-01

    Background Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. Results We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. Conclusion CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets. PMID:23617892

  14. A fluorescence anisotropy method for measuring protein concentration in complex cell culture media.

    PubMed

    Groza, Radu Constantin; Calvet, Amandine; Ryder, Alan G

    2014-04-22

    The rapid, quantitative analysis of the complex cell culture media used in biopharmaceutical manufacturing is of critical importance. Requirements for cell culture media composition profiling, or changes in specific analyte concentrations (e.g. amino acids in the media or product protein in the bioprocess broth) often necessitate the use of complicated analytical methods and extensive sample handling. Rapid spectroscopic methods like multi-dimensional fluorescence (MDF) spectroscopy have been successfully applied for the routine determination of compositional changes in cell culture media and bioprocess broths. Quantifying macromolecules in cell culture media is a specific challenge as there is a need to implement measurements rapidly on the prepared media. However, the use of standard fluorescence spectroscopy is complicated by the emission overlap from many media components. Here, we demonstrate how combining anisotropy measurements with standard total synchronous fluorescence spectroscopy (TSFS) provides a rapid, accurate quantitation method for cell culture media. Anisotropy provides emission resolution between large and small fluorophores while TSFS provides a robust measurement space. Model cell culture media was prepared using yeastolate (2.5 mg mL(-1)) spiked with bovine serum albumin (0 to 5 mg mL(-1)). Using this method, protein emission is clearly discriminated from background yeastolate emission, allowing for accurate bovine serum albumin (BSA) quantification over a 0.1 to 4.0 mg mL(-1) range with a limit of detection (LOD) of 13.8 μg mL(-1). Copyright © 2014. Published by Elsevier B.V.

  15. Compression-based distance (CBD): a simple, rapid, and accurate method for microbiota composition comparison.

    PubMed

    Yang, Fang; Chia, Nicholas; White, Bryan A; Schook, Lawrence B

    2013-04-23

    Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets.

  16. Rapid Presentation of Emotional Expressions Reveals New Emotional Impairments in Tourette’s Syndrome

    PubMed Central

    Mermillod, Martial; Devaux, Damien; Derost, Philippe; Rieu, Isabelle; Chambres, Patrick; Auxiette, Catherine; Legrand, Guillaume; Galland, Fabienne; Dalens, Hélène; Coulangeon, Louise Marie; Broussolle, Emmanuel; Durif, Franck; Jalenques, Isabelle

    2013-01-01

    Objective: Based on a variety of empirical evidence obtained within the theoretical framework of embodiment theory, we considered it likely that motor disorders in Tourette’s syndrome (TS) would have emotional consequences for TS patients. However, previous research using emotional facial categorization tasks suggests that these consequences are limited to TS patients with obsessive-compulsive behaviors (OCB). Method: These studies used long stimulus presentations which allowed the participants to categorize the different emotional facial expressions (EFEs) on the basis of a perceptual analysis that might potentially hide a lack of emotional feeling for certain emotions. In order to reduce this perceptual bias, we used a rapid visual presentation procedure. Results: Using this new experimental method, we revealed different and surprising impairments on several EFEs in TS patients compared to matched healthy control participants. Moreover, a spatial frequency analysis of the visual signal processed by the patients suggests that these impairments may be located at a cortical level. Conclusion: The current study indicates that the rapid visual presentation paradigm makes it possible to identify various potential emotional disorders that were not revealed by the standard visual presentation procedures previously reported in the literature. Moreover, the spatial frequency analysis performed in our study suggests that emotional deficit in TS might lie at the level of temporal cortical areas dedicated to the processing of HSF visual information. PMID:23630481

  17. The Java Image Science Toolkit (JIST) for rapid prototyping and publishing of neuroimaging software.

    PubMed

    Lucas, Blake C; Bogovic, John A; Carass, Aaron; Bazin, Pierre-Louis; Prince, Jerry L; Pham, Dzung L; Landman, Bennett A

    2010-03-01

    Non-invasive neuroimaging techniques enable extraordinarily sensitive and specific in vivo study of the structure, functional response and connectivity of biological mechanisms. With these advanced methods comes a heavy reliance on computer-based processing, analysis and interpretation. While the neuroimaging community has produced many excellent academic and commercial tool packages, new tools are often required to interpret new modalities and paradigms. Developing custom tools and ensuring interoperability with existing tools is a significant hurdle. To address these limitations, we present a new framework for algorithm development that implicitly ensures tool interoperability, generates graphical user interfaces, provides advanced batch processing tools, and, most importantly, requires minimal additional programming or computational overhead. Java-based rapid prototyping with this system is an efficient and practical approach to evaluate new algorithms since the proposed system ensures that rapidly constructed prototypes are actually fully-functional processing modules with support for multiple GUI's, a broad range of file formats, and distributed computation. Herein, we demonstrate MRI image processing with the proposed system for cortical surface extraction in large cross-sectional cohorts, provide a system for fully automated diffusion tensor image analysis, and illustrate how the system can be used as a simulation framework for the development of a new image analysis method. The system is released as open source under the Lesser GNU Public License (LGPL) through the Neuroimaging Informatics Tools and Resources Clearinghouse (NITRC).

  18. The Java Image Science Toolkit (JIST) for Rapid Prototyping and Publishing of Neuroimaging Software

    PubMed Central

    Lucas, Blake C.; Bogovic, John A.; Carass, Aaron; Bazin, Pierre-Louis; Prince, Jerry L.; Pham, Dzung

    2010-01-01

    Non-invasive neuroimaging techniques enable extraordinarily sensitive and specific in vivo study of the structure, functional response and connectivity of biological mechanisms. With these advanced methods comes a heavy reliance on computer-based processing, analysis and interpretation. While the neuroimaging community has produced many excellent academic and commercial tool packages, new tools are often required to interpret new modalities and paradigms. Developing custom tools and ensuring interoperability with existing tools is a significant hurdle. To address these limitations, we present a new framework for algorithm development that implicitly ensures tool interoperability, generates graphical user interfaces, provides advanced batch processing tools, and, most importantly, requires minimal additional programming or computational overhead. Java-based rapid prototyping with this system is an efficient and practical approach to evaluate new algorithms since the proposed system ensures that rapidly constructed prototypes are actually fully-functional processing modules with support for multiple GUI's, a broad range of file formats, and distributed computation. Herein, we demonstrate MRI image processing with the proposed system for cortical surface extraction in large cross-sectional cohorts, provide a system for fully automated diffusion tensor image analysis, and illustrate how the system can be used as a simulation framework for the development of a new image analysis method. The system is released as open source under the Lesser GNU Public License (LGPL) through the Neuroimaging Informatics Tools and Resources Clearinghouse (NITRC). PMID:20077162

  19. Rapid Isolation of Phenol Degrading Bacteria by Fourier Transform Infrared (FTIR) Spectroscopy.

    PubMed

    Li, Fei; Song, Wen-jun; Wei, Ji-ping; Wang, Su-ying; Liu, Chong-ji

    2015-05-01

    Phenol is an important chemical engineering material and ubiquitous in industry wastewater, its existence has become a thorny issue in many developed and developing country. More and more stringent standards for effluent all over the world with human realizing the toxicity of phenol have been announced. Many advanced biological methods are applied to industrial wastewater treatment with low cost, high efficiency and no secondary pollution, but the screening of function microorganisms is certain cumbersome process. In our study a rapid procedure devised for screening bacteria on solid medium can degrade phenol coupled with attenuated total reflection fourier transform infrared (ATR-FTIR) which is a detection method has the characteristics of efficient, fast, high fingerprint were used. Principal component analysis (PCA) is a method in common use to extract fingerprint peaks effectively, it couples with partial least squares (PLS) statistical method could establish a credible model. The model we created using PCA-PLS can reach 99. 5% of coefficient determination and validation data get 99. 4%, which shows the promising fitness and forecasting of the model. The high fitting model is used for predicting the concentration of phenol at solid medium where the bacteria were grown. The highly consistent result of two screening methods, solid cultural with ATR-FTIR detected and traditional liquid cultural detected by GC methods, suggests the former can rapid isolate the bacteria which can degrade substrates as well as traditional cumbersome liquid cultural method. Many hazardous substrates widely existed in industry wastewater, most of them has specialize fingerprint peaks detected by ATR-FTIR, thereby this detected method could be used as a rapid detection for isolation of functional microorganisms those can degrade many other toxic substrates.

  20. A rapid and efficient newly established method to detect COL1A1-PDGFB gene fusion in dermatofibrosarcoma protuberans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yokoyama, Yoko; Shimizu, Akira; Okada, Etsuko

    Highlights: Black-Right-Pointing-Pointer We developed new method to rapidly identify COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer New PCR method using a single primer pair detected COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer This is the first report of DFSP with a novel COL1A1 breakpoint in exon 5. -- Abstract: The detection of fusion transcripts of the collagen type 1{alpha}1 (COL1A1) and platelet-derived growth factor-BB (PDGFB) genes by genetic analysis has recognized as a reliable and valuable molecular tool for the diagnosis of dermatofibrosarcoma protuberans (DFSP). To detect the COL1A1-PDGFB fusion, almost previous reports performed reverse transcription polymerase chain reaction (RT-PCR) using multiplex forward primersmore » from COL1A1. However, it has possible technical difficulties with respect to the handling of multiple primers and reagents in the procedure. The objective of this study is to establish a rapid, easy, and efficient one-step method of PCR using only a single primer pair to detect the fusion transcripts of the COL1A1 and PDGFB in DFSP. To validate new method, we compared the results of RT-PCR in five patients of DFSP between the previous method using multiplex primers and our established one-step RT-PCR using a single primer pair. In all cases of DFSP, the COL1A1-PDGFB fusion was detected by both previous method and newly established one-step PCR. Importantly, we detected a novel COL1A1 breakpoint in exon 5. The newly developed method is valuable to rapidly identify COL1A1-PDGFB fusion transcripts in DFSP.« less

  1. Rapid detection of Ganoderma-infected oil palms by microwave ergosterol extraction with HPLC and TLC.

    PubMed

    Muniroh, M S; Sariah, M; Zainal Abidin, M A; Lima, N; Paterson, R R M

    2014-05-01

    Detection of basal stem rot (BSR) by Ganoderma of oil palms was based on foliar symptoms and production of basidiomata. Enzyme-Linked Immunosorbent Assays-Polyclonal Antibody (ELISA-PAB) and PCR have been proposed as early detection methods for the disease. These techniques are complex, time consuming and have accuracy limitations. An ergosterol method was developed which correlated well with the degree of infection in oil palms, including samples growing in plantations. However, the method was capable of being optimised. This current study was designed to develop a simpler, more rapid and efficient ergosterol method with utility in the field that involved the use of microwave extraction. The optimised procedure involved extracting a small amount of Ganoderma, or Ganoderma-infected oil palm suspended in low volumes of solvent followed by irradiation in a conventional microwave oven at 70°C and medium high power for 30s, resulting in simultaneous extraction and saponification. Ergosterol was detected by thin layer chromatography (TLC) and quantified using high performance liquid chromatography with diode array detection. The TLC method was novel and provided a simple, inexpensive method with utility in the field. The new method was particularly effective at extracting high yields of ergosterol from infected oil palm and enables rapid analysis of field samples on site, allowing infected oil palms to be treated or culled very rapidly. Some limitations of the method are discussed herein. The procedures lend themselves to controlling the disease more effectively and allowing more effective use of land currently employed to grow oil palms, thereby reducing pressure to develop new plantations. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Microfluidic direct injection method for analysis of urinary 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) using molecularly imprinted polymers coupled on-line with LC-MS/MS.

    PubMed

    Shah, Kumar A; Peoples, Michael C; Halquist, Matthew S; Rutan, Sarah C; Karnes, H Thomas

    2011-01-25

    The work described in this paper involves development of a high-throughput on-line microfluidic sample extraction method using capillary micro-columns packed with MIP beads coupled with tandem mass spectrometry for the analysis of urinary NNAL. The method was optimized and matrix effects were evaluated and resolved. The method enabled low sample volume (200 μL) and rapid analysis of urinary NNAL by direct injection onto the microfluidic column packed with molecularly imprinted beads engineered to NNAL. The method was validated according to the FDA bioanalytical method validation guidance. The dynamic range extended from 20.0 to 2500.0 pg/mL with a percent relative error of ±5.9% and a run time of 7.00 min. The lower limit of quantitation was 20.0 pg/mL. The method was used for the analysis of NNAL and NNAL-Gluc concentrations in smokers' urine. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Bacillus subtilis as a bioindicator for estimating pentachlorophenol toxicity and concentration.

    PubMed

    Ayude, M A; Okada, E; González, J F; Haure, P M; Murialdo, S E

    2009-05-01

    Pentachlorophenol (PCP) and its sodium salt (Na-PCP) are extremely toxic chemicals responsible for important soil and groundwater pollution, mainly caused by wastes from wood-treatment plants, because chlorinated phenols are widely used as wood preservatives. The methods most commonly used for routine analysis of pesticides such as PCP and Na-PCP are high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS). A variety of rapid biological screening tests using marine organisms, bioluminescent bacteria, and enzymes have also been reported. In this study, rapid biological screening analysis using Bacillus subtilis was developed, to assess the biodegradation of PCP and its by-products in liquid samples. An empirical model is proposed for spectrophotometric analysis of Na-PCP concentration after growth of Bacillus subtilis.

  4. Rapid analysis of microbial systems using vibrational spectroscopy and supervised learning methods: application to the discrimination between methicillin-resistant and methicillin-susceptible Staphy

    NASA Astrophysics Data System (ADS)

    Goodacre, Royston; Rooney, Paul J.; Kell, Douglas B.

    1998-04-01

    FTIR spectra were obtained from 15 methicillin-resistant and 22 methicillin-susceptible Staphylococcus aureus strains using our DRASTIC approach. Cluster analysis showed that the major source of variation between the IR spectra was not due to their resistance or susceptibility to methicillin; indeed early studies suing pyrolysis mass spectrometry had shown that this unsupervised analysis gave information on the phage group of the bacteria. By contrast, artificial neural networks, based on a supervised learning, could be trained to recognize those aspects of the IR spectra which differentiated methicillin-resistant from methicillin- susceptible strains. These results give the first demonstration that the combination of FTIR with neural networks can provide a very rapid and accurate antibiotic susceptibility testing technique.

  5. Analysis of multiple vitamin D metabolites by ultra-performance supercritical fluid chromatography-tandem mass spectrometry (UPSFC-MS/MS).

    PubMed

    Jenkinson, Carl; Taylor, Angela; Storbeck, Karl-Heinz; Hewison, Martin

    2018-06-15

    In recent years, increased interest in the human health benefits of vitamin D has led to demand for improved analysis of patient vitamin D 'status'. Studies to date have focused primarily on a single vitamin D metabolite, 25-hydroxyvitamin D, despite the existence of a broad range of vitamin D metabolites, referred to as the vitamin D metabolome. This study reports on the development of a rapid UPSFC-MS/MS method for the analysis of nine vitamin D metabolites in human serum. Optimum separation was obtained with a Lux-Cellulose chiral column. We observed an orthogonal elution order when compared with ultra-high performance liquid chromatography (UHPLC). The order of elution was reversed based on hydroxyl- group number, however elution order did not differ between isomeric changes in hydroxyl- group position or epimers. Although UPSFC yielded superior resolution and selectivity over previously developed UHPLC-MS/MS methods, improvements in sensitivity could not be achieved owing to the lower injection volume required for UPSFC relative to UHPLC. Method validation was performed on the developed UPSFC-MS/MS method and found to be within acceptable limits. Applying the method to the analysis of human serum samples showed a significant correlation with serum concentrations of metabolites measured by UHPLC-MS/MS (25OHD3 r = 0.997, P=<0.001, and 3-epi-25OHD3 r = 0.996, P ≤0.001). These data indicate that UPSFC provides an efficient analytical platform for rapid analysis of multiple vitamin D metabolites from serum. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  6. Demonstration and Evaluation of Solid Phase Microextraction for the Assessment of Bioavailability and Contaminant Mobility. ESTCP Cost and Performance Report

    DTIC Science & Technology

    2012-08-01

    subsequent chemical analysis (into acetonitrile for high-performance liquid chromatography [ HPLC ] analysis or hexane for gas chromatography [GC... analysis ) is rapid and complete. In this work, PAHs were analyzed by Waters 2795 HPLC with fluorescent detection (USEPA Method 8310) and PCBs were...detection limits by direct water injection versus SPME with PDMS and coefficient of variation and correlation coefficient for SPME. Analysis by HPLC

  7. Statistical Methods for Rapid Aerothermal Analysis and Design Technology: Validation

    NASA Technical Reports Server (NTRS)

    DePriest, Douglas; Morgan, Carolyn

    2003-01-01

    The cost and safety goals for NASA s next generation of reusable launch vehicle (RLV) will require that rapid high-fidelity aerothermodynamic design tools be used early in the design cycle. To meet these requirements, it is desirable to identify adequate statistical models that quantify and improve the accuracy, extend the applicability, and enable combined analyses using existing prediction tools. The initial research work focused on establishing suitable candidate models for these purposes. The second phase is focused on assessing the performance of these models to accurately predict the heat rate for a given candidate data set. This validation work compared models and methods that may be useful in predicting the heat rate.

  8. Biomagnetic separation of Salmonella Typhimurium with high affine and specific ligand peptides isolated by phage display technique

    NASA Astrophysics Data System (ADS)

    Steingroewer, Juliane; Bley, Thomas; Bergemann, Christian; Boschke, Elke

    2007-04-01

    Analyses of food-borne pathogens are of great importance in order to minimize the health risk for customers. Thus, very sensitive and rapid detection methods are required. Current conventional culture techniques are very time consuming. Modern immunoassays and biochemical analysis also require pre-enrichment steps resulting in a turnaround time of at least 24 h. Biomagnetic separation (BMS) is a promising more rapid method. In this study we describe the isolation of high affine and specific peptides from a phage-peptide library, which combined with BMS allows the detection of Salmonella spp. with a similar sensitivity as that of immunomagnetic separation using antibodies.

  9. Rapid process development of chromatographic process using direct analysis in real time mass spectrometry as a process analytical technology tool.

    PubMed

    Yan, Binjun; Chen, Teng; Xu, Zhilin; Qu, Haibin

    2014-06-01

    The concept of quality by design (QbD) is widely applied in the process development of pharmaceuticals. However, the additional cost and time have caused some resistance about QbD implementation. To show a possible solution, this work proposed a rapid process development method, which used direct analysis in real time mass spectrometry (DART-MS) as a process analytical technology (PAT) tool for studying the chromatographic process of Ginkgo biloba L., as an example. The breakthrough curves were fast determined by DART-MS at-line. A high correlation coefficient of 0.9520 was found between the concentrations of ginkgolide A determined by DART-MS and HPLC. Based on the PAT tool, the impacts of process parameters on the adsorption capacity were discovered rapidly, which showed a decreased adsorption capacity with the increase of the flow rate. This work has shown the feasibility and advantages of integrating PAT into QbD implementation for rapid process development. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Time-Resolved Fluorescent Immunochromatography of Aflatoxin B1 in Soybean Sauce: A Rapid and Sensitive Quantitative Analysis.

    PubMed

    Wang, Du; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Zhang, Wen

    2016-07-14

    Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatography. The dynamic range of a competitive and portable immunoassay was 0.3-10.0 µg·kg(-1), with a limit of detection (LOD) of 0.1 µg·kg(-1) and recoveries of 87.2%-114.3%, within 10 min. The results showed good correlation (R² > 0.99) between time-resolved fluorescent immunochromatographic strip test and high performance liquid chromatography (HPLC). Soybean sauce samples analyzed using time-resolved fluorescent immunochromatographic strip test revealed that 64.2% of samples contained aflatoxin B1 at levels ranging from 0.31 to 12.5 µg·kg(-1). The strip test is a rapid, sensitive, quantitative, and cost-effective on-site screening technique in food safety analysis.

  11. Autoclave method for rapid preparation of bacterial PCR-template DNA.

    PubMed

    Simmon, Keith E; Steadman, Dewey D; Durkin, Sarah; Baldwin, Amy; Jeffrey, Wade H; Sheridan, Peter; Horton, Rene; Shields, Malcolm S

    2004-02-01

    An autoclave method for preparing bacterial DNA for PCR template is presented, it eliminates the use of detergents, organic solvents, and mechanical cellular disruption approaches, thereby significantly reducing processing time and costs while increasing reproducibility. Bacteria are lysed by rapid heating and depressurization in an autoclave. The lysate, cleared by microcentrifugation, was either used directly in the PCR reaction, or concentrated by ultrafiltration. This approach was compared with seven established methods of DNA template preparation from four bacterial sources which included boiling Triton X-100 and SDS, bead beating, lysozyme/proteinase K, and CTAB lysis method components. Bacteria examined were Enterococcus and Escherichia coli, a natural marine bacterial community and an Antarctic cyanobacterial-mat. DNAs were tested for their suitability as PCR templates by repetitive element random amplified polymorphic DNA (RAPD) and denaturing gradient gel electrophoresis (DGGE) analysis. The autoclave method produced PCR amplifiable template comparable or superior to the other methods, with greater reproducibility, much shorter processing time, and at a significantly lower cost.

  12. A Lipid Extraction and Analysis Method for Characterizing Soil Microbes in Experiments with Many Samples

    PubMed Central

    Oates, Lawrence G.; Read, Harry W.; Gutknecht, Jessica L. M.; Duncan, David S.; Balser, Teri B.; Jackson, Randall D.

    2017-01-01

    Microbial communities are important drivers and regulators of ecosystem processes. To understand how management of ecosystems may affect microbial communities, a relatively precise but effort-intensive technique to assay microbial community composition is phospholipid fatty acid (PLFA) analysis. PLFA was developed to analyze phospholipid biomarkers, which can be used as indicators of microbial biomass and the composition of broad functional groups of fungi and bacteria. It has commonly been used to compare soils under alternative plant communities, ecology, and management regimes. The PLFA method has been shown to be sensitive to detecting shifts in microbial community composition. An alternative method, fatty acid methyl ester extraction and analysis (MIDI-FA) was developed for rapid extraction of total lipids, without separation of the phospholipid fraction, from pure cultures as a microbial identification technique. This method is rapid but is less suited for soil samples because it lacks an initial step separating soil particles and begins instead with a saponification reaction that likely produces artifacts from the background organic matter in the soil. This article describes a method that increases throughput while balancing effort and accuracy for extraction of lipids from the cell membranes of microorganisms for use in characterizing both total lipids and the relative abundance of indicator lipids to determine soil microbial community structure in studies with many samples. The method combines the accuracy achieved through PLFA profiling by extracting and concentrating soil lipids as a first step, and a reduction in effort by saponifying the organic material extracted and processing with the MIDI-FA method as a second step. PMID:28745639

  13. Tracking B-Cell Repertoires and Clonal Histories in Normal and Malignant Lymphocytes.

    PubMed

    Weston-Bell, Nicola J; Cowan, Graeme; Sahota, Surinder S

    2017-01-01

    Methods for tracking B-cell repertoires and clonal history in normal and malignant B-cells based on immunoglobulin variable region (IGV) gene analysis have developed rapidly with the advent of massive parallel next-generation sequencing (mpNGS) protocols. mpNGS permits a depth of analysis of IGV genes not hitherto feasible, and presents challenges of bioinformatics analysis, which can be readily met by current pipelines. This strategy offers a potential resolution of B-cell usage at a depth that may capture fully the natural state, in a given biological setting. Conventional methods based on RT-PCR amplification and Sanger sequencing are also available where mpNGS is not accessible. Each method offers distinct advantages. Conventional methods for IGV gene sequencing are readily adaptable to most laboratories and provide an ease of analysis to capture salient features of B-cell use. This chapter describes two methods in detail for analysis of IGV genes, mpNGS and conventional RT-PCR with Sanger sequencing.

  14. Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies.

    PubMed

    Keane, Pearse A; Grossi, Carlota M; Foster, Paul J; Yang, Qi; Reisman, Charles A; Chan, Kinpui; Peto, Tunde; Thomas, Dhanes; Patel, Praveen J

    2016-01-01

    To describe an approach to the use of optical coherence tomography (OCT) imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness. In UK Biobank, OCT images were acquired between 2009 and 2010 using a commercially available "spectral domain" OCT device (3D OCT-1000, Topcon). Images were obtained using a raster scan protocol, 6 mm x 6 mm in area, and consisting of 128 B-scans. OCT image sets were stored on UK Biobank servers in a central repository, adjacent to high performance computers. Rapid, automated analysis of retinal thickness was performed using custom image segmentation software developed by the Topcon Advanced Biomedical Imaging Laboratory (TABIL). This software employs dual-scale gradient information to allow for automated segmentation of nine intraretinal boundaries in a rapid fashion. 67,321 participants (134,642 eyes) in UK Biobank underwent OCT imaging of both eyes as part of the ocular module. 134,611 images were successfully processed with 31 images failing segmentation analysis due to corrupted OCT files or withdrawal of subject consent for UKBB study participation. Average time taken to call up an image from the database and complete segmentation analysis was approximately 120 seconds per data set per login, and analysis of the entire dataset was completed in approximately 28 days. We report an approach to the rapid, automated measurement of retinal thickness from nearly 140,000 OCT image sets from the UK Biobank. In the near future, these measurements will be publically available for utilization by researchers around the world, and thus for correlation with the wealth of other data collected in UK Biobank. The automated analysis approaches we describe may be of utility for future large population-based epidemiological studies, clinical trials, and screening programs that employ OCT imaging.

  15. Magnetic solid phase extraction coupled with desorption corona beam ionization-mass spectrometry for rapid analysis of antidepressants in human body fluids.

    PubMed

    Chen, Di; Zheng, Hao-Bo; Huang, Yun-Qing; Hu, Yu-Ning; Yu, Qiong-Wei; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-08-21

    Ambient ionization techniques show good potential in rapid analysis of target compounds. However, a direct application of these ambient ionization techniques for the determination of analytes in a complex matrix is difficult due to the matrix interference and ion suppression. To resolve this problem, here we developed a strategy by coupling magnetic solid phase extraction (MSPE) with desorption corona beam ionization (DCBI)-mass spectrometry (MS). As a proof of concept, the pyrrole-coated Fe3O4 magnetic nanoparticles (Fe3O4@Ppy) were prepared and used for the extraction of antidepressants. After extraction, the Fe3O4@Ppy with trapped antidepressants was then directly subjected to DCBI-MS analysis with the aid of a homemade magnetic glass capillary. As the MSPE process is rapid and the direct DCBI-MS analysis does not need solvent desorption or chromatographic separation processes, the overall analysis can be completed within 3 min. The proposed MSPE-DCBI-MS method was then successfully used to determine antidepressants in human urine and plasma. The calibration curves were obtained in the range of 0.005-0.5 μg mL(-1) for urine and 0.02-1 μg mL(-1) for plasma with reasonable linearity (R(2) > 0.951). The limits of detection of three antidepressants were in the range of 0.2-1 ng mL(-1) for urine and 2-5 ng mL(-1) for plasma. Acceptable reproducibility for rapid analysis was achieved with relative standard deviations less than 19.1% and the relative recoveries were 85.2-118.7%. Taken together, the developed MSPE-DCBI-MS strategy offers a powerful capacity for rapid analysis of target compounds in a complex matrix, which would greatly expand the applications of ambient ionization techniques with plentiful magnetic sorbents.

  16. Development of a novel hexa-plex PCR method for identification and serotyping of Salmonella species.

    PubMed

    Li, Ruichao; Wang, Yang; Shen, Jianzhong; Wu, Congming

    2014-01-01

    Salmonella is one of the most important foodborne pathogens, which causes a huge economic burden worldwide. To detect Salmonella rapidly is very meaningful in preventing salmonellosis and decreasing economic losses. Currently, isolation of Salmonella is confirmed by biochemical and serobased serotyping methods, which are time consuming, labor intensive, and complicated. To solve this problem, a hexa-plex polymerase chain reaction (PCR) method was developed using comparative genomics analysis and multiplex PCR technology to detect Salmonella and Salmonella Typhimurium, Salmonella Enteritidis, Salmonella Agona, Salmonella Choleraesuis, and Salmonella Pullorum simultaneously. The accuracy of this method was tested by a collection of 142 Salmonella. Furthermore, the strategy described in this article to mine serovar-specific fragments for Salmonella could be used to find specific fragments for other Salmonella serotypes and bacteria. The combination of this strategy and multiplex PCR is promising in the rapid identification of foodborne pathogens.

  17. Rapid Radiochemical Analyses in Support of Fukushima Nuclear Accident - 13196

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    There is an increasing need to develop faster analytical methods for emergency response, including emergency soil and air filter samples [1, 2]. The Savannah River National Laboratory (SRNL) performed analyses on samples received from Japan in April, 2011 as part of a U.S. Department of Energy effort to provide assistance to the government of Japan, following the nuclear event at Fukushima Daiichi, resulting from the earthquake and tsunami on March 11, 2011. Of particular concern was whether it was safe to plant rice in certain areas (prefectures) near Fukushima. The primary objectives of the sample collection, sample analysis, and datamore » assessment teams were to evaluate personnel exposure hazards, identify the nuclear power plant radiological source term and plume deposition, and assist the government of Japan in assessing any environmental and agricultural impacts associated with the nuclear event. SRNL analyzed approximately 250 samples and reported approximately 500 analytical method determinations. Samples included soil from farmland surrounding the Fukushima reactors and air monitoring samples of national interest, including those collected at the U.S. Embassy and American military bases. Samples were analyzed for a wide range of radionuclides, including strontium-89, strontium-90, gamma-emitting radionuclides, and plutonium, uranium, americium and curium isotopes. Technical aspects of the rapid soil and air filter analyses will be described. The extent of radiostrontium contamination was a significant concern. For {sup 89,90}Sr analyses on soil samples, a rapid fusion technique using 1.5 gram soil aliquots to enable a Minimum Detectable Activity (MDA) of <1 pCi {sup 89,90}Sr /g of soil was employed. This sequential technique has been published recently by this laboratory for actinides and radiostrontium in soil and vegetation [3, 4]. It consists of a rapid sodium hydroxide fusion, pre-concentration steps using iron hydroxide and calcium fluoride precipitations, followed by Sr-Resin separation and gas flow proportional counting. To achieve a lower detection limit for analysis of some of the Japanese soil samples, a 10 gram aliquot of soil was taken, acid-leached and processed with similar preconcentration chemistry. The MDA using this approach was ∼0.03 pCi/g (1.1 mBq/g)/, which is less than the 0.05-0.10 pCi/g {sup 90}Sr levels found in soil as a result of global fallout. The chemical yields observed for the Japanese soil samples was typically 75-80% and the laboratory control sample (LCS) and matrix spike (MS) results looked very good for this work Individual QC results were well within the ± 25% acceptable range and the average of these results does not show significant bias. Additional data for a radiostrontium in soil method for 50 gram samples will also be presented, which appears to be a significant step forward based on looking at the current literature, with higher chemical yields for even larger sample aliquots and lower MDA [5, 6, 7] Hou et al surveyed a wide range of separation methods for Pu in waters and environmental solid samples [8]. While there are many actinide methods in the scientific literature, few would be considered rapid due to the tedious and time-consuming steps involved. For actinide analyses in soil, a new rapid method for the determination of actinide isotopes in soil samples using both alpha spectrometry and inductively-coupled plasma mass spectrometry was employed. The new rapid soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. [9, 10] Vacuum box technology and rapid flow rates were used to reduce analytical time. Challenges associated with the mineral content in the volcanic soil will be discussed. Air filter samples were reported within twenty-four (24) hours of receipt using rapid techniques published previously. [11] The rapid reporting of high quality analytical data arranged through the U.S. Department of Energy Consequence Management Home Team was critical to allow the government of Japan to readily evaluate radiological impacts from the nuclear reactor incident to both personnel and the environment. SRNL employed unique rapid methods capability for radionuclides to support Japan that can also be applied to environmental, bioassay and waste management samples. New rapid radiochemical techniques for radionuclides in soil and other environmental matrices as well as some of the unique challenges associated with this work will be presented that can be used for application to environmental monitoring, environmental remediation, decommissioning and decontamination activities. (authors)« less

  18. RAPID RADIOCHEMICAL ANALYSES IN SUPPORT OF FUKUSHIMA NUCLEAR ACCIDENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.

    2012-11-07

    There is an increasing need to develop faster analytical methods for emergency response, including emergency soil and air filter samples. The Savannah River National Laboratory (SRNL) performed analyses on samples received from Japan in April, 2011 as part of a U.S. Department of Energy effort to provide assistance to the government of Japan, following the nuclear event at Fukushima Daiichi, resulting from the earthquake and tsunami on March 11, 2011. Of particular concern was whether it was safe to plant rice in certain areas (prefectures) near Fukushima. The primary objectives of the sample collection, sample analysis, and data assessment teamsmore » were to evaluate personnel exposure hazards, identify the nuclear power plant radiological source term and plume deposition, and assist the government of Japan in assessing any environmental and agricultural impacts associated with the nuclear event. SRNL analyzed approximately 250 samples and reported approximately 500 analytical method determinations. Samples included soil from farmland surrounding the Fukushima reactors and air monitoring samples of national interest, including those collected at the U.S. Embassy and American military bases. Samples were analyzed for a wide range of radionuclides, including strontium-89, strontium-90, gamma-emitting radionuclides, and plutonium, uranium, americium and curium isotopes. Technical aspects of the rapid soil and air filter analyses will be described. The extent of radiostrontium contamination was a significant concern. For {sup 89,90}Sr analyses on soil samples, a rapid fusion technique using 1.5 gram soil aliquots to enable a Minimum Detectable Activity (MDA) of <1 pCi {sup 89,90} Sr /g of soil was employed. This sequential technique has been published recently by this laboratory for actinides and radiostrontium in soil and vegetation. It consists of a rapid sodium hydroxide fusion, pre-concentration steps using iron hydroxide and calcium fluoride precipitations, followed by Sr-Resin separation and gas flow proportional counting. To achieve a lower detection limit for analysis of some of the Japanese soil samples, a 10 gram aliquot of soil was taken, acid-leached and processed with similar preconcentration chemistry. The MDA using this approach was ~0.03 pCi/g (1.1 mBq/g)/, which is less than the 0.05-0.10 pCi/g {sup 90}Sr levels found in soil as a result of global fallout. The chemical yields observed for the Japanese soil samples was typically 75-80% and the laboratory control sample (LCS) and matrix spike (MS) results looked very good for this work Individual QC results were well within the ± 25% acceptable range and the average of these results does not show significant bias. Additional data for a radiostrontium in soil method for 50 gram samples will also be presented, which appears to be a significant step forward based on looking at the current literature, with higher chemical yields for even larger sample aliquots and lower MDA. Hou et al surveyed a wide range of separation methods for Pu in waters and environmental solid samples. While there are many actinide methods in the scientific literature, few would be considered rapid due to the tedious and time-consuming steps involved. For actinide analyses in soil, a new rapid method for the determination of actinide isotopes in soil samples using both alpha spectrometry and inductively-coupled plasma mass spectrometry was employed. The new rapid soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates were used to reduce analytical time. Challenges associated with the mineral content in the volcanic soil will be discussed. Air filter samples were reported within twenty-four (24) hours of receipt using rapid techniques published previously. The rapid reporting of high quality analytical data arranged through the U.S. Department of Energy Consequence Management Home Team was critical to allow the government of Japan to readily evaluate radiological impacts from the nuclear reactor incident to both personnel and the environment. SRNL employed unique rapid methods capability for radionuclides to support Japan that can also be applied to environmental, bioassay and waste management samples. New rapid radiochemical techniques for radionuclides in soil and other environmental matrices as well as some of the unique challenges associated with this work will be presented that can be used for application to environmental monitoring, environmental remediation, decommissioning and decontamination activities.« less

  19. Actuarial analysis of surgical results: rationale and method.

    PubMed

    Grunkemeier, G L; Starr, A

    1977-11-01

    The use of time-related methods of statistical analysis is essential for valid evaluation of the long-term results of a surgical procedure. Accurate comparison of two procedures or two prosthetic devices is possible only when the length of follow-up is properly accounted for. The purpose of this report is to make the technical aspects of the acturial, or life table, method easily accessible to the surgeon, with emphasis on the motivation for and the rationale behind it. This topic is illustrated in terms of heart valve prostheses, a field that is rapidly developing. Both the authors and readers of articles must be aware that controversies surrounding the relative merits of various prosthetic designs or operative procedures can be settled only if proper time-related methods of analysis are utilized.

  20. Variability analysis of the bulk resistivity measured using concrete cylinders.

    DOT National Transportation Integrated Search

    2011-01-01

    "Many agencies are interested in using a rapid test method for measuring the electrical properties of concrete (i.e., the : resistivity or conductivity) since the electrical properties can be related to fluid transport (e.g., ion diffusion). The adva...

  1. Rapid acquisition of data dense solid-state CPMG NMR spectral sets using multi-dimensional statistical analysis

    DOE PAGES

    Mason, H. E.; Uribe, E. C.; Shusterman, J. A.

    2018-01-01

    Tensor-rank decomposition methods have been applied to variable contact time 29 Si{ 1 H} CP/CPMG NMR data sets to extract NMR dynamics information and dramatically decrease conventional NMR acquisition times.

  2. Rapid acquisition of data dense solid-state CPMG NMR spectral sets using multi-dimensional statistical analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mason, H. E.; Uribe, E. C.; Shusterman, J. A.

    Tensor-rank decomposition methods have been applied to variable contact time 29 Si{ 1 H} CP/CPMG NMR data sets to extract NMR dynamics information and dramatically decrease conventional NMR acquisition times.

  3. Lectin-Array Blotting.

    PubMed

    Pazos, Raquel; Echevarria, Juan; Hernandez, Alvaro; Reichardt, Niels-Christian

    2017-09-01

    Aberrant protein glycosylation is a hallmark of cancer, infectious diseases, and autoimmune or neurodegenerative disorders. Unlocking the potential of glycans as disease markers will require rapid and unbiased glycoproteomics methods for glycan biomarker discovery. The present method is a facile and rapid protocol for qualitative analysis of protein glycosylation in complex biological mixtures. While traditional lectin arrays only provide an average signal for the glycans in the mixture, which is usually dominated by the most abundant proteins, our method provides individual lectin binding profiles for all proteins separated in the gel electrophoresis step. Proteins do not have to be excised from the gel for subsequent analysis via the lectin array but are transferred by contact diffusion from the gel to a glass slide presenting multiple copies of printed lectin arrays. Fluorescently marked glycoproteins are trapped by the printed lectins via specific carbohydrate-lectin interactions and after a washing step their binding profile with up to 20 lectin probes is analyzed with a fluorescent scanner. The method produces the equivalent of 20 lectin blots in a single experiment, giving detailed insight into the binding epitopes present in the fractionated proteins. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  4. Rapid Detection and Simultaneous Genotyping of Cronobacter spp. (formerly Enterobacter sakazakii) in Powdered Infant Formula Using Real-time PCR and High Resolution Melting (HRM) Analysis

    PubMed Central

    Cai, Xian-Quan; Yu, Hai-Qiong; Ruan, Zhou-Xi; Yang, Lei-Liang; Bai, Jian-Shan; Qiu, De-Yi; Jian, Zhi-Hua; Xiao, Yi-Qian; Yang, Jie-Yang; Le, Thanh Hoa; Zhu, Xing-Quan

    2013-01-01

    Cronobacter spp. is an emerging pathogen that causes meningitis, sepsis, bacteremia, and necrotizing enterocolitis in neonates and children. The present study developed an assay integrating real-time PCR and high resolution melting (HRM) analysis targeting the OmpA gene for the specific detection and rapid identification of Cronobacter spp. (formerly Enterobacter sakazakii) in powdered infant formula. Eleven Cronobacter field isolates and 25 reference strains were examined using one pair of primers, having the accuracy of 100% in reference to conventional methods. The assay was proved to be highly sensitive with a detection limit of 102 CFU/ml without pre-enrichment, and highly concordant (100%) when compared with ISO-IDF 22964 in 89 actual samples. The method performed for Cronobacter spp. detection was less than 24 h, drastically shortened, compared to several days using standard culturing method, it is probe-free and reduces a risk of PCR carryover. Moreover, all Cronobacter strains examined in this study were genotyped into two species according to their HRM profiles. The established method should provide a molecular tool for direct detection and simultaneous genotyping of Cronobacter spp. in powdered infant formula. PMID:23825624

  5. Rapid detection and simultaneous genotyping of Cronobacter spp. (formerly Enterobacter sakazakii) in powdered infant formula using real-time PCR and high resolution melting (HRM) analysis.

    PubMed

    Cai, Xian-Quan; Yu, Hai-Qiong; Ruan, Zhou-Xi; Yang, Lei-Liang; Bai, Jian-Shan; Qiu, De-Yi; Jian, Zhi-Hua; Xiao, Yi-Qian; Yang, Jie-Yang; Le, Thanh Hoa; Zhu, Xing-Quan

    2013-01-01

    Cronobacter spp. is an emerging pathogen that causes meningitis, sepsis, bacteremia, and necrotizing enterocolitis in neonates and children. The present study developed an assay integrating real-time PCR and high resolution melting (HRM) analysis targeting the OmpA gene for the specific detection and rapid identification of Cronobacter spp. (formerly Enterobacter sakazakii) in powdered infant formula. Eleven Cronobacter field isolates and 25 reference strains were examined using one pair of primers, having the accuracy of 100% in reference to conventional methods. The assay was proved to be highly sensitive with a detection limit of 10(2) CFU/ml without pre-enrichment, and highly concordant (100%) when compared with ISO-IDF 22964 in 89 actual samples. The method performed for Cronobacter spp. detection was less than 24 h, drastically shortened, compared to several days using standard culturing method, it is probe-free and reduces a risk of PCR carryover. Moreover, all Cronobacter strains examined in this study were genotyped into two species according to their HRM profiles. The established method should provide a molecular tool for direct detection and simultaneous genotyping of Cronobacter spp. in powdered infant formula.

  6. Analysis of fluorescently labeled glycosphingolipid-derived oligosaccharides following ceramide glycanase digestion and anthranilic acid labeling.

    PubMed

    Neville, David C A; Coquard, Virginie; Priestman, David A; te Vruchte, Danielle J M; Sillence, Daniel J; Dwek, Raymond A; Platt, Frances M; Butters, Terry D

    2004-08-15

    Interest in cellular glycosphingolipid (GSL) function has necessitated the development of a rapid and sensitive method to both analyze and characterize the full complement of structures present in various cells and tissues. An optimized method to characterize oligosaccharides released from glycosphingolipids following ceramide glycanase digestion has been developed. The procedure uses the fluorescent compound anthranilic acid (2-aminobenzoic acid; 2-AA) to label oligosaccharides prior to analysis using normal-phase high-performance liquid chromatography. The labeling procedure is rapid, selective, and easy to perform and is based on the published method of Anumula and Dhume [Glycobiology 8 (1998) 685], originally used to analyze N-linked oligosaccharides. It is less time consuming than a previously published 2-aminobenzamide labeling method [Anal. Biochem. 298 (2001) 207] for analyzing GSL-derived oligosaccharides, as the fluorescent labeling is performed on the enzyme reaction mixture. The purification of 2-AA-labeled products has been improved to ensure recovery of oligosaccharides containing one to four monosaccharide units, which was not previously possible using the Anumula and Dhume post-derivatization purification procedure. This new approach may also be used to analyze both N- and O-linked oligosaccharides.

  7. Rapid and sensitive analysis of 27 underivatized free amino acids, dipeptides, and tripeptides in fruits of Siraitia grosvenorii Swingle using HILIC-UHPLC-QTRAP(®)/MS (2) combined with chemometrics methods.

    PubMed

    Zhou, Guisheng; Wang, Mengyue; Li, Yang; Peng, Ying; Li, Xiaobo

    2015-08-01

    In the present study, a new strategy based on chemical analysis and chemometrics methods was proposed for the comprehensive analysis and profiling of underivatized free amino acids (FAAs) and small peptides among various Luo-Han-Guo (LHG) samples. Firstly, the ultrasound-assisted extraction (UAE) parameters were optimized using Plackett-Burman (PB) screening and Box-Behnken designs (BBD), and the following optimal UAE conditions were obtained: ultrasound power of 280 W, extraction time of 43 min, and the solid-liquid ratio of 302 mL/g. Secondly, a rapid and sensitive analytical method was developed for simultaneous quantification of 24 FAAs and 3 active small peptides in LHG at trace levels using hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole linear ion-trap tandem mass spectrometry (HILIC-UHPLC-QTRAP(®)/MS(2)). The analytical method was validated by matrix effects, linearity, LODs, LOQs, precision, repeatability, stability, and recovery. Thirdly, the proposed optimal UAE conditions and analytical methods were applied to measurement of LHG samples. It was shown that LHG was rich in essential amino acids, which were beneficial nutrient substances for human health. Finally, based on the contents of the 27 analytes, the chemometrics methods of unsupervised principal component analysis (PCA) and supervised counter propagation artificial neural network (CP-ANN) were applied to differentiate and classify the 40 batches of LHG samples from different cultivated forms, regions, and varieties. As a result, these samples were mainly clustered into three clusters, which illustrated the cultivating disparity among the samples. In summary, the presented strategy had potential for the investigation of edible plants and agricultural products containing FAAs and small peptides.

  8. Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry.

    PubMed

    Li, Ming; Zhang, Jingjing; Jiang, Jie; Zhang, Jing; Gao, Jing; Qiao, Xiaolin

    2014-04-07

    In this paper, a novel approach based on paper spray ionization coupled with ion mobility spectrometry (PSI-IMS) was developed for rapid, in situ detection of cocaine residues in liquid samples and on various surfaces (e.g. glass, marble, skin, wood, fingernails), without tedious sample pretreatment. The obvious advantages of PSI are its low cost, easy operation and simple configuration without using nebulizing gas or discharge gas. Compared with mass spectrometry, ion mobility spectrometry (IMS) takes advantage of its low cost, easy operation, and simple configuration without requiring a vacuum system. Therefore, IMS is a more congruous detection method for PSI in the case of rapid, in situ analysis. For the analysis of cocaine residues in liquid samples, dynamic responses from 5 μg mL(-1) to 200 μg mL(-1) with a linear coefficient (R(2)) of 0.992 were obtained. In this case, the limit of detection (LOD) was calculated to be 2 μg mL(-1) as signal to noise (S/N) was 3 with a relative standard deviation (RSD) of 6.5% for 11 measurements (n = 11). Cocaine residues on various surfaces such as metal, glass, marble, wood, skin, and fingernails were also directly analyzed before wiping the surfaces with a piece of paper. The LOD was calculated to be as low as 5 ng (S/N = 3, RSD = 6.3%, n = 11). This demonstrates the capability of the PSI-IMS method for direct detection of cocaine residues at scenes of cocaine administration. Our results show that PSI-IMS is a simple, sensitive, rapid and economical method for in situ detection of this illicit drug, which could help governments to combat drug abuse.

  9. Identification of urinary tract pathogens after 3-hours urine culture by MALDI-TOF mass spectrometry.

    PubMed

    Haiko, Johanna; Savolainen, Laura E; Hilla, Risto; Pätäri-Sampo, Anu

    2016-10-01

    Complicated urinary tract infections, such as pyelonephritis, may lead to sepsis. Rapid diagnosis is needed to identify the causative urinary pathogen and to verify the appropriate empirical antimicrobial therapy. We describe here a rapid identification method for urinary pathogens: urine is incubated on chocolate agar for 3h at 35°C with 5% CO2 and subjected to MALDI-TOF MS analysis by VITEK MS. Overall 207 screened clinical urine samples were tested in parallel with conventional urine culture. The method, called U-si-MALDI-TOF (urine short incubation MALDI-TOF), showed correct identification for 86% of Gram-negative urinary tract pathogens (Escherichia coli, Klebsiella pneumoniae, and other Enterobacteriaceae), when present at >10(5)cfu/ml in culture (n=107), compared with conventional culture method. However, Gram-positive bacteria (n=28) were not successfully identified by U-si-MALDI-TOF. This method is especially suitable for rapid identification of E. coli, the most common cause of urinary tract infections and urosepsis. Turnaround time for identification using U-si-MALDI-TOF compared with conventional urine culture was improved from 24h to 4-6h. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

  11. Analysis of compositional monosaccharides in fungus polysaccharides by capillary zone electrophoresis.

    PubMed

    Hu, Yuanyuan; Wang, Tong; Yang, Xingbin; Zhao, Yan

    2014-02-15

    A rapid analytical method of capillary zone electrophoresis (CZE) was established for the simultaneous separation and determination of 10 monosaccharides (aldoses and uronic acids). The monosaccharides were labeled with 1-phenyl-3-methyl-5-pyrazolone (PMP), and subsequently separated using an uncoated capillary (50 μm i.d. × 58.5 cm) and detected by UV at 245 nm with pH 11.0, 175 mM borate buffer at voltage 20 kV and capillary temperature 25 °C by CZE. The 10 PMP-labeled monosaccharides were rapidly baseline separated within 20 min. The optimized CZE method was successfully applied to the simultaneous separation and identification of the monosaccharide composition in Termitomyces albuminosus polysaccharides (TAPs) and Panus giganteus polysaccharides (PGPs). The quantitative recovery of the component monosaccharides in the fungus polysaccharides was in the range of 92.0-101.0% and the CV value was lower than 3.5%. The results demonstrate that the proposed CZE method is precise and practical for the monosaccharide analysis of fungus polysaccharides. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Application of handheld and portable spectrometers for screening acrylamide content in commercial potato chips.

    PubMed

    Ayvaz, Huseyin; Rodriguez-Saona, Luis E

    2015-05-01

    The most common methods for acrylamide analysis in foods require the use of LC-MS/MS and GC-MS. Although these methods have great analytical performance, they need intensive sample preparation, highly specialised instrumentation, and are time consuming. In this study, portable and handheld infrared spectrometers were evaluated as rapid methods for screening acrylamide in potato chips and their performances were compared to those of benchtop infrared systems. The acrylamide content of 64 commercial potato chips (169-2453 μg/kg) was determined by LC-MS/MS. Spectral data were collected using mid-infrared (MIR) and near-infrared (NIR) spectrometers. Partial least squares regression (PLSR) calibration models were developed to predict acrylamide levels. Overall, good linear correlation was found between the predicted acrylamide levels and actual measured acrylamide concentrations by LC-MS/MS (rPred > 0.90 and SEP < 100 μg/kg). Our results indicate that portable and handheld spectrometers can be used as simple and rapid alternatives for acrylamide analysis in potato chips. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. A manual and an automatic TERS based virus discrimination

    NASA Astrophysics Data System (ADS)

    Olschewski, Konstanze; Kämmer, Evelyn; Stöckel, Stephan; Bocklitz, Thomas; Deckert-Gaudig, Tanja; Zell, Roland; Cialla-May, Dana; Weber, Karina; Deckert, Volker; Popp, Jürgen

    2015-02-01

    Rapid techniques for virus identification are more relevant today than ever. Conventional virus detection and identification strategies generally rest upon various microbiological methods and genomic approaches, which are not suited for the analysis of single virus particles. In contrast, the highly sensitive spectroscopic technique tip-enhanced Raman spectroscopy (TERS) allows the characterisation of biological nano-structures like virions on a single-particle level. In this study, the feasibility of TERS in combination with chemometrics to discriminate two pathogenic viruses, Varicella-zoster virus (VZV) and Porcine teschovirus (PTV), was investigated. In a first step, chemometric methods transformed the spectral data in such a way that a rapid visual discrimination of the two examined viruses was enabled. In a further step, these methods were utilised to perform an automatic quality rating of the measured spectra. Spectra that passed this test were eventually used to calculate a classification model, through which a successful discrimination of the two viral species based on TERS spectra of single virus particles was also realised with a classification accuracy of 91%.Rapid techniques for virus identification are more relevant today than ever. Conventional virus detection and identification strategies generally rest upon various microbiological methods and genomic approaches, which are not suited for the analysis of single virus particles. In contrast, the highly sensitive spectroscopic technique tip-enhanced Raman spectroscopy (TERS) allows the characterisation of biological nano-structures like virions on a single-particle level. In this study, the feasibility of TERS in combination with chemometrics to discriminate two pathogenic viruses, Varicella-zoster virus (VZV) and Porcine teschovirus (PTV), was investigated. In a first step, chemometric methods transformed the spectral data in such a way that a rapid visual discrimination of the two examined viruses was enabled. In a further step, these methods were utilised to perform an automatic quality rating of the measured spectra. Spectra that passed this test were eventually used to calculate a classification model, through which a successful discrimination of the two viral species based on TERS spectra of single virus particles was also realised with a classification accuracy of 91%. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr07033j

  14. A Simple Method for Rapid Depletion of Rubisco from Soybean (Glycine max) Leaf for Proteomic Analysis of Lower Abundance Proteins

    USDA-ARS?s Scientific Manuscript database

    2-DE analysis of complex plant proteomes has limited dynamic resolution because only abundant proteins can be detected. Proteomic assessment of the low abundance proteins within leaf tissue is difficult when it is comprised of 30 – 50% of the CO2 fixation enzyme Rubisco. Resolution can be improved t...

  15. Rapid Determination of Lymphogranuloma Venereum Serovars of Chlamydia trachomatis by Quantitative High-Resolution Melt Analysis (HRMA)

    PubMed Central

    Stevens, Matthew P.; Garland, Suzanne M.; Zaia, Angelo M.; Tabrizi, Sepehr N.

    2012-01-01

    A quantitative high-resolution melt analysis assay was developed to differentiate lymphogranuloma venereum-causing serovars of Chlamydia trachomatis (L1 to L3) from other C. trachomatis serovars (D to K). The detection limit of this assay is approximately 10 copies per reaction, comparable to the limits of other quantitative-PCR-based methods. PMID:22933594

  16. Rapid Analysis and Manufacturing Propulsion Technology (RAMPT)

    NASA Technical Reports Server (NTRS)

    Fikes, John C.

    2018-01-01

    NASA's strategic plan calls for the development of enabling technologies, improved production methods, and advanced design and analysis tools related to the agency's objectives to expand human presence in the solar system. NASA seeks to advance exploration, science, innovation, benefits to humanity, and international collaboration, as well as facilitate and utilize U.S. commercial capabilities to deliver cargo and crew to space.

  17. Trial-by-Trial Analysis or Averaging: Implications for Electromyographic Models of Rapid Limb Control

    ERIC Educational Resources Information Center

    Sherwood, David E.; Enebo, Brian A.

    2007-01-01

    The control of human limb movement has been the focus of research for more than a century. A major issue to emerge from this work is the manner in which the central nervous system regulates electromyographic (EMG) activity to produce movements that differ in distance, velocity, and movement time. However, the different methods of analysis often…

  18. Working postures of dental students: ergonomic analysis using the Ovako Working Analysis System and rapid upper limb assessment.

    PubMed

    Petromilli Nordi Sasso Garcia, Patrícia; Polli, Gabriela Scatimburgo; Campos, Juliana Alvares Duarte Bonini

    2013-01-01

    As dentistry is a profession that demands a manipulative precision of hand movements, musculoskeletal disorders are among the most common occupational diseases. This study estimated the risk of musculoskeletal disorders developing in dental students using the Ovako Working Analysis System (OWAS) and Rapid Upper Limb Assessment (RULA) methods, and estimated the diagnostic agreement between the 2 methods. Students (n = 75), enrolled in the final undergraduate year at the Araraquara School of Dentistry--UNESP--were studied. Photographs were taken of students while performing diverse clinical procedures (n = 283) using a digital camera, which were assessed using OWAS and RULA. A risk score was attributed following each procedure performed by the student. The prevalence of the risk of musculoskeletal disorders was estimated per point and for a 95% CI. To assess the agreement between the 2 methods, Kappa statistics with linear weighting were used. The level of significance adopted was 5%. There was a high prevalence of the mean score for risk of musculoskeletal disorders in the dental students evaluated according to the OWAS method (p = 97.88%; 95% CI: 96.20-99.56%), and a high prevalence of the high score (p = 40.6; 95% CI: 34.9-46.4%) and extremely high risk (p = 59.4%; 95% CI: 53.6-65.1%) according to RULA method Null agreement was verified (k = 0) in the risk di agnosis of the tested methods. The risk of musculoskeletal disorders in dental students estimated by the OWAS method was medium, whereas the same risk by the RULA method was extremely high. There was no diagnostic agreement between the OWAS and RULA methods.

  19. Vibration and stress analysis of soft-bonded shuttle insulation tiles. Modal analysis with compact widely space stringers

    NASA Technical Reports Server (NTRS)

    Ojalvo, I. U.; Austin, F.; Levy, A.

    1974-01-01

    An efficient iterative procedure is described for the vibration and modal stress analysis of reusable surface insulation (RSI) of multi-tiled space shuttle panels. The method, which is quite general, is rapidly convergent and highly useful for this application. A user-oriented computer program based upon this procedure and titled RESIST (REusable Surface Insulation Stresses) has been prepared for the analysis of compact, widely spaced, stringer-stiffened panels. RESIST, which uses finite element methods, obtains three dimensional tile stresses in the isolator, arrestor (if any) and RSI materials. Two dimensional stresses are obtained in the tile coating and the stringer-stiffened primary structure plate. A special feature of the program is that all the usual detailed finite element grid data is generated internally from a minimum of input data. The program can accommodate tile idealizations with up to 850 nodes (2550 degrees-of-freedom) and primary structure idealizations with a maximum of 10,000 degrees-of-freedom. The primary structure vibration capability is achieved through the development of a new rapid eigenvalue program named ALARM (Automatic LArge Reduction of Matrices to tridiagonal form).

  20. Trial application of oxygen and carbon isotope analysis in tooth enamel for identification of past-war victims for discriminating between Japanese and US soldiers.

    PubMed

    Someda, Hidetoshi; Gakuhari, Takashi; Akai, Junko; Araki, Yoshiyuki; Kodera, Tsutomu; Tsumatori, Gentaro; Kobayashi, Yasushi; Matsunaga, Satoru; Abe, Shinichi; Hashimoto, Masatsugu; Saito, Megumi; Yoneda, Minoru; Ishida, Hajime

    2016-04-01

    Stable isotope analysis has undergone rapid development in recent years and yielded significant results in the field of forensic sciences. In particular, carbon and oxygen isotopic ratios in tooth enamel obtained from human remains can provide useful information for the crosschecking of morphological and DNA analyses and facilitate rapid on-site prescreening for the identification of remains. This study analyzes carbon and oxygen isotopic ratios in the tooth enamel of Japanese people born between 1878 and 1930, in order to obtain data for methodological differentiation of Japanese and American remains from the Second World War. The carbon and oxygen isotopic ratios in the tooth enamel of the examined Japanese individuals are compared to previously reported data for American individuals (born post WWII), and statistical analysis is conducted using a discrimination method based on a logistic regression analysis. The discrimination between the Japanese and US populations, including Alaska and Hawaii, is found to be highly accurate. Thus, the present method has potential as a discrimination technique for both populations for use in the examination of mixed remains comprising Japanese and American fallen soldiers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Augmenting Conceptual Design Trajectory Tradespace Exploration with Graph Theory

    NASA Technical Reports Server (NTRS)

    Dees, Patrick D.; Zwack, Mathew R.; Steffens, Michael; Edwards, Stephen

    2016-01-01

    Within conceptual design changes occur rapidly due to a combination of uncertainty and shifting requirements. To stay relevant in this fluid time, trade studies must also be performed rapidly. In order to drive down analysis time while improving the information gained by these studies, surrogate models can be created to represent the complex output of a tool or tools within a specified tradespace. In order to create this model however, a large amount of data must be collected in a short amount of time. By this method, the historical approach of relying on subject matter experts to generate the data required is schedule infeasible. However, by implementing automation and distributed analysis the required data can be generated in a fraction of the time. Previous work focused on setting up a tool called multiPOST capable of orchestrating many simultaneous runs of an analysis tool assessing these automated analyses utilizing heuristics gleaned from the best practices of current subject matter experts. In this update to the previous work, elements of graph theory are included to further drive down analysis time by leveraging data previously gathered. It is shown to outperform the previous method in both time required, and the quantity and quality of data produced.

  2. Rapid prediction of ochratoxin A-producing strains of Penicillium on dry-cured meat by MOS-based electronic nose.

    PubMed

    Lippolis, Vincenzo; Ferrara, Massimo; Cervellieri, Salvatore; Damascelli, Anna; Epifani, Filomena; Pascale, Michelangelo; Perrone, Giancarlo

    2016-02-02

    The availability of rapid diagnostic methods for monitoring ochratoxigenic species during the seasoning processes for dry-cured meats is crucial and constitutes a key stage in order to prevent the risk of ochratoxin A (OTA) contamination. A rapid, easy-to-perform and non-invasive method using an electronic nose (e-nose) based on metal oxide semiconductors (MOS) was developed to discriminate dry-cured meat samples in two classes based on the fungal contamination: class P (samples contaminated by OTA-producing Penicillium strains) and class NP (samples contaminated by OTA non-producing Penicillium strains). Two OTA-producing strains of Penicillium nordicum and two OTA non-producing strains of Penicillium nalgiovense and Penicillium salamii, were tested. The feasibility of this approach was initially evaluated by e-nose analysis of 480 samples of both Yeast extract sucrose (YES) and meat-based agar media inoculated with the tested Penicillium strains and incubated up to 14 days. The high recognition percentages (higher than 82%) obtained by Discriminant Function Analysis (DFA), either in calibration and cross-validation (leave-more-out approach), for both YES and meat-based samples demonstrated the validity of the used approach. The e-nose method was subsequently developed and validated for the analysis of dry-cured meat samples. A total of 240 e-nose analyses were carried out using inoculated sausages, seasoned by a laboratory-scale process and sampled at 5, 7, 10 and 14 days. DFA provided calibration models that permitted discrimination of dry-cured meat samples after only 5 days of seasoning with mean recognition percentages in calibration and cross-validation of 98 and 88%, respectively. A further validation of the developed e-nose method was performed using 60 dry-cured meat samples produced by an industrial-scale seasoning process showing a total recognition percentage of 73%. The pattern of volatile compounds of dry-cured meat samples was identified and characterized by a developed HS-SPME/GC-MS method. Seven volatile compounds (2-methyl-1-butanol, octane, 1R-α-pinene, d-limonene, undecane, tetradecanal, 9-(Z)-octadecenoic acid methyl ester) allowed discrimination between dry-cured meat samples of classes P and NP. These results demonstrate that MOS-based electronic nose can be a useful tool for a rapid screening in preventing OTA contamination in the cured meat supply chain. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Rapid direct analysis to discriminate geographic origin of extra virgin olive oils by flash gas chromatography electronic nose and chemometrics.

    PubMed

    Melucci, Dora; Bendini, Alessandra; Tesini, Federica; Barbieri, Sara; Zappi, Alessandro; Vichi, Stefania; Conte, Lanfranco; Gallina Toschi, Tullia

    2016-08-01

    At present, the geographical origin of extra virgin olive oils can be ensured by documented traceability, although chemical analysis may add information that is useful for possible confirmation. This preliminary study investigated the effectiveness of flash gas chromatography electronic nose and multivariate data analysis to perform rapid screening of commercial extra virgin olive oils characterized by a different geographical origin declared in the label. A comparison with solid phase micro extraction coupled to gas chromatography mass spectrometry was also performed. The new method is suitable to verify the geographic origin of extra virgin olive oils based on principal components analysis and discriminant analysis applied to the volatile profile of the headspace as a fingerprint. The selected variables were suitable in discriminating between "100% Italian" and "non-100% Italian" oils. Partial least squares discriminant analysis also allowed prediction of the degree of membership of unknown samples to the classes examined. Copyright © 2016. Published by Elsevier Ltd.

  4. Novel Composites for Wing and Fuselage Applications: Speedy Nonlinear Analysis of Postbuckled Panels in Shear (SNAPPS)

    NASA Technical Reports Server (NTRS)

    Sharp, Dave; Sobel, Larry

    1997-01-01

    A simple and rapid analysis method, consisting of a number of modular, 'strength-of-materials-type' models, is presented for predicting the nonlinear response and stiffener separation of postbuckled, flat, composite, shear panels. The analysis determines the maximum principal tensile stress in the skin surface layer under to toe. Failure is said to occur when this stress reaches the mean transverse tensile strength of the layer. The analysis methodology consists of a number of closed-form equations that can easily be used in a 'hand analysis. For expediency, they have been programmed into a preliminary design code called SNAPPS (Speedy Nonlinear Analysis of Postbuckled Panels in Shear), which rapidly predicts postbuckling response of the panel for each value of the applied shear load. SNAPPS response and failure predictions were found to agree well with test results for three panels with widely different geometries, laminates and stiffnesses. Design guidelines are given for increasing the load-carrying capacity of stiffened, composite shear panels.

  5. Recent developments in fast spectroscopy for plant mineral analysis

    PubMed Central

    van Maarschalkerweerd, Marie; Husted, Søren

    2015-01-01

    Ideal fertilizer management to optimize plant productivity and quality is more relevant than ever, as global food demands increase along with the rapidly growing world population. At the same time, sub-optimal or excessive use of fertilizers leads to severe environmental damage in areas of intensive crop production. The approaches of soil and plant mineral analysis are briefly compared and discussed here, and the new techniques using fast spectroscopy that offer cheap, rapid, and easy-to-use analysis of plant nutritional status are reviewed. The majority of these methods use vibrational spectroscopy, such as visual-near infrared and to a lesser extent ultraviolet and mid-infrared spectroscopy. Advantages of and problems with application of these techniques are thoroughly discussed. Spectroscopic techniques considered having major potential for plant mineral analysis, such as chlorophyll a fluorescence, X-ray fluorescence, and laser-induced breakdown spectroscopy are also described. PMID:25852719

  6. The Development and Validation of a Rapid Assessment Tool of Primary Care in China

    PubMed Central

    Mei, Jie; Liang, Yuan; Shi, LeiYu; Zhao, JingGe; Wang, YuTan; Kuang, Li

    2016-01-01

    Introduction. With Chinese health care reform increasingly emphasizing the importance of primary care, the need for a tool to evaluate primary care performance and service delivery is clear. This study presents a methodology for a rapid assessment of primary care organizations and service delivery in China. Methods. The study translated and adapted the Primary Care Assessment Tool-Adult Edition (PCAT-AE) into a Chinese version to measure core dimensions of primary care, namely, first contact, continuity, comprehensiveness, and coordination. A cross-sectional survey was conducted to assess the validity and reliability of the Chinese Rapid Primary Care Assessment Tool (CR-PCAT). Eight community health centers in Guangdong province have been selected to participate in the survey. Results. A total of 1465 effective samples were included for data analysis. Eight items were eliminated following principal component analysis and reliability testing. The principal component analysis extracted five multiple-item scales (first contact utilization, first contact accessibility, ongoing care, comprehensiveness, and coordination). The tests of scaling assumptions were basically met. Conclusion. The standard psychometric evaluation indicates that the scales have achieved relatively good reliability and validity. The CR-PCAT provides a rapid and reliable measure of four core dimensions of primary care, which could be applied in various scenarios. PMID:26885509

  7. Development of a dynamic headspace gas chromatography-mass spectrometry method for on-site analysis of sulfur mustard degradation products in sediments.

    PubMed

    Magnusson, R; Nordlander, T; Östin, A

    2016-01-15

    Sampling teams performing work at sea in areas where chemical munitions may have been dumped require rapid and reliable analytical methods for verifying sulfur mustard leakage from suspected objects. Here we present such an on-site analysis method based on dynamic headspace GC-MS for analysis of five cyclic sulfur mustard degradation products that have previously been detected in sediments from chemical weapon dumping sites: 1,4-oxathiane, 1,3-dithiolane, 1,4-dithiane, 1,4,5-oxadithiephane, and 1,2,5-trithiephane. An experimental design involving authentic Baltic Sea sediments spiked with the target analytes was used to develop an optimized protocol for sample preparation, headspace extraction and analysis that afforded recoveries of up to 60-90%. The optimized method needs no organic solvents, uses only two grams of sediment on a dry weight basis and involves a unique sample presentation whereby sediment is spread uniformly as a thin layer inside the walls of a glass headspace vial. The method showed good linearity for analyte concentrations of 5-200 ng/g dw, good repeatability, and acceptable carry-over. The method's limits of detection for spiked sediment samples ranged from 2.5 to 11 μg/kg dw, with matrix interference being the main limiting factor. The instrumental detection limits were one to two orders of magnitude lower. Full-scan GC-MS analysis enabled the use of automated mass spectral deconvolution for rapid identification of target analytes. Using this approach, analytes could be identified in spiked sediment samples at concentrations down to 13-65 μg/kg dw. On-site validation experiments conducted aboard the research vessel R/V Oceania demonstrated the method's practical applicability, enabling the successful identification of four cyclic sulfur mustard degradation products at concentrations of 15-308μg/kg in sediments immediately after being collected near a wreck at the Bornholm Deep dumpsite in the Baltic Sea. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harben, P E; Harris, D; Myers, S

    Seismic imaging and tracking methods have intelligence and monitoring applications. Current systems, however, do not adequately calibrate or model the unknown geological heterogeneity. Current systems are also not designed for rapid data acquisition and analysis in the field. This project seeks to build the core technological capabilities coupled with innovative deployment, processing, and analysis methodologies to allow seismic methods to be effectively utilized in the applications of seismic imaging and vehicle tracking where rapid (minutes to hours) and real-time analysis is required. The goal of this project is to build capabilities in acquisition system design, utilization and in full 3Dmore » finite difference modeling as well as statistical characterization of geological heterogeneity. Such capabilities coupled with a rapid field analysis methodology based on matched field processing are applied to problems associated with surveillance, battlefield management, finding hard and deeply buried targets, and portal monitoring. This project benefits the U.S. military and intelligence community in support of LLNL's national-security mission. FY03 was the final year of this project. In the 2.5 years this project has been active, numerous and varied developments and milestones have been accomplished. A wireless communication module for seismic data was developed to facilitate rapid seismic data acquisition and analysis. The E3D code was enhanced to include topographic effects. Codes were developed to implement the Karhunen-Loeve (K-L) statistical methodology for generating geological heterogeneity that can be utilized in E3D modeling. The matched field processing methodology applied to vehicle tracking and based on a field calibration to characterize geological heterogeneity was tested and successfully demonstrated in a tank tracking experiment at the Nevada Test Site. A 3-seismic-array vehicle tracking testbed was installed on-site at LLNL for testing real-time seismic tracking methods. A field experiment was conducted over a tunnel at the Nevada Site that quantified the tunnel reflection signal and, coupled with modeling, identified key needs and requirements in experimental layout of sensors. A large field experiment was conducted at the Lake Lynn Laboratory, a mine safety research facility in Pennsylvania, over a tunnel complex in realistic, difficult conditions. This experiment gathered the necessary data for a full 3D attempt to apply the methodology. The experiment also collected data to analyze the capabilities to detect and locate in-tunnel explosions for mine safety and other applications.« less

  9. Loop-mediated isothermal amplification for detection of Staphylococcus aureus in dairy cow suffering from mastitis.

    PubMed

    Tie, Zhang; Chunguang, Wang; Xiaoyuan, Wei; Xinghua, Zhao; Xiuhui, Zhong

    2012-01-01

    To develop a rapid detection method of Staphylococcus aureus using loop-mediated isothermal amplification (LAMP), four specific primers were designed according to six distinct sequences of the nuc gene. In addition, the specificity and sensitivity of LAMP were verified and compared with those of PCR. Results showed that the LAMP reaction was completed within 45 min at 62.5°C, and ladder bands were appeared in LAMP products analyzed by gel electrophoresis. After adding 1x SYBR Green l, the positive reaction tube showed green color and the negative reaction tube remained orange, indicating that the LAMP has high specificity. The minimal detectable concentration of LAMP was 1 × 10² CFU/mL and that of PCR was 1 × 10⁴ CFU/mL, indicating that the LAMP was 100 times more sensitive than the PCR. The LAMP method for detection of Staphylococcus aureus has many advantages, such as simple operation, high sensitivity, high specificity, and rapid analysis. Therefore, this method is more suitable for the rapid on-site detection of Staphylococcus aureus.

  10. Rapid and nondestructive method for evaluation of embryo culture media using drop coating deposition Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Zufang; Sun, Yan; Wang, Jing; Du, Shengrong; Li, Yongzeng; Lin, Juqiang; Feng, Shangyuan; Lei, Jinping; Lin, Hongxin; Chen, Rong; Zeng, Haishan

    2013-12-01

    In this study, a rapid and simple method which combines drop coating deposition and Raman spectroscopy (DCDR) was developed to characterize the dry embryo culture media (ECM) droplet. We demonstrated that Raman spectra obtained from the droplet edge presented useful and characteristic signatures for protein and amino acids assessment. Using a different analytical method, scanning electron microscopy coupled with energy dispersive X-ray analysis, we further confirmed that Na, K, and Cl were mainly detected in the central area of the dry ECM droplet while sulphur, an indicative of the presence of macromolecules such as proteins, was mainly found at the periphery of the droplet. In addition, to reduce sample preparation time, different temperatures for drying the droplets were tested. The results showed that drying temperature at 50°C can effectively reduce the sample preparation time to 6 min (as compared to 50 min for drying at room temperature, ˜25°C) without inducing thermal damage to the proteins. This work demonstrated that DCDR has potential for rapid and reliable metabolomic profiling of ECM in clinical applications.

  11. Multiple search methods for similarity-based virtual screening: analysis of search overlap and precision

    PubMed Central

    2011-01-01

    Background Data fusion methods are widely used in virtual screening, and make the implicit assumption that the more often a molecule is retrieved in multiple similarity searches, the more likely it is to be active. This paper tests the correctness of this assumption. Results Sets of 25 searches using either the same reference structure and 25 different similarity measures (similarity fusion) or 25 different reference structures and the same similarity measure (group fusion) show that large numbers of unique molecules are retrieved by just a single search, but that the numbers of unique molecules decrease very rapidly as more searches are considered. This rapid decrease is accompanied by a rapid increase in the fraction of those retrieved molecules that are active. There is an approximately log-log relationship between the numbers of different molecules retrieved and the number of searches carried out, and a rationale for this power-law behaviour is provided. Conclusions Using multiple searches provides a simple way of increasing the precision of a similarity search, and thus provides a justification for the use of data fusion methods in virtual screening. PMID:21824430

  12. Facile and sensitive determination of N-nitrosamines in food samples by high-performance liquid chromatography via combining fluorescent labeling with dispersive liquid-liquid microextraction.

    PubMed

    Lu, Shuaimin; Wu, Di; Li, Guoliang; Lv, Zhengxian; Gong, Peiwei; Xia, Lian; Sun, Zhiwei; Chen, Guang; Chen, Xuefeng; You, Jinmao; Wu, Yongning

    2017-11-01

    The intake of N-nitrosamines (NAs) from foodstuffs is considered to be an important influence factor for several cancers. But the rapid and sensitive screening of NAs remains a challenge in the field of food safety. Inspired by that, a sensitive and rapid method was demonstrated for determination of five NAs (Nitrosopyrrolidine, Nitrosodimethylamine, Nitrosodiethylamine, Nitrosodipropylamine and Nitrosodibutylamine) using dispersive liquid-liquid microextraction (DLLME) followed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The NAs were firstly denitrosated and labeled by 2-(11H-benzo[a]carbazol-11-yl) ethyl carbonochloridate (BCEC-Cl) and finally enriched by DLLME. Furthermore, the main DLLME conditions were optimized systematically. Under the optimal conditions, satisfactory limits of detection (LODs) were obtained with a range of 0.01-0.07ngg -1 , which were significantly lower than the reported methods. The developed method showed many merits including rapidity, simplicity, high sensitivity and excellent selectivity, which shows a broad prospect in food safety analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. A novel method for rapid in vitro radiobioassay

    NASA Astrophysics Data System (ADS)

    Crawford, Evan Bogert

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are the detonation of a radiation dispersal device (RDD, "dirty bomb") or the accidental release of an isotope from an industrial source such as a radioisotopic thermal generator (RTG). In the event of the release and dispersion of radioactive materials into the environment in a large city, the entire population of the city -- including all commuting workers and tourists -- would have to be rapidly tested, both to satisfy the psychological needs of the citizens who were exposed to the mental trauma of a possible radiation dose, and to satisfy the immediate medical needs of those who received the highest doses and greatest levels of internal contamination -- those who would best benefit from rapid, intensive medical care. In this research a prototype rapid screening method to screen urine samples for the presence of up to five isotopes, both individually and in a mixture, has been developed. The isotopes used to develop this method are Co-60, Sr-90, Cs-137, Pu-238, and Am-241. This method avoids time-intensive chemical separations via the preparation and counting of a single sample on multiple detectors, and analyzing the spectra for isotope-specific markers. A rapid liquid-liquid separation using an organic extractive scintillator can be used to help quantify the activity of the alpha-emitting isotopes. The method provides quantifiable results in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their respective intervention levels in approximately 30 minutes of sample preparation and counting time. Radiation detector spectra -- e.g. those from high-purity germanium (HPGe) gamma detectors and liquid scintillation detectors -- which contain decay signals from multiple isotopes often have overlapping signals: the counts from one isotope's decay can appear in energy channels associated with another isotope's decay, complicating the calculation of each isotope's activity. The uncertainties associated with analyzing these spectra have been traced in order to determine the effects of one isotope's count rate on the sensitivity and uncertainty associated with each other isotope. The method that was developed takes advantage of activated carbon filtration to eliminate quenching effects and to make the liquid scintillation spectra from different urine samples comparable. The method uses pulse-shape analysis to reduce the interference from beta emitters in the liquid scintillation spectrum and improve the minimum detectable activity (MDA) and minimum quantifiable activity (MQA) for alpha emitters. The method uses an HPGe detector to quantify the activity of gamma emitters, and subtract their isotopes' contributions to the liquid scintillation spectra via a calibration factor, such that the pure beta and pure alpha emitters can be identified and quantified from the resulting liquid scintillation spectra. Finally, the method optionally uses extractive scintillators to rapidly separate the alpha emitters from the beta emitters when the activity from the beta emitters is too great to detect or quantify the activity from the alpha emitters without such a separation. The method is able to detect and quantify all five isotopes, with uncertainties and biases usually in the 10-40% range, depending upon the isotopic mixtures and the activity ratios between each of the isotopes.

  14. Analysis of free amino acids in Amur sturgeon by ultra-performance liquid chromatography using pre-column derivatization with 6-aminoquinolyl-carbamyl.

    PubMed

    Sun, Yanchun; Xu, Xianzhu; Mou, Zhenbo; Wang, Jing; Tan, Zhijun; Wu, Song

    2012-12-01

    A rapid, sensitive, and reliable ultra-performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6-aminoquinolyl-carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C(18) column with Acetonitrile-acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5-1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Rapid steroid hormone quantification for congenital adrenal hyperplasia (CAH) in dried blood spots using UPLC liquid chromatography-tandem mass spectrometry.

    PubMed

    Janzen, Nils; Sander, Stefanie; Terhardt, Michael; Steuerwald, Ulrike; Peter, Michael; Das, Anibh M; Sander, Johannes

    2011-12-11

    Newborn screening for congenital adrenal hyperplasia (CAH) is usually done by quantifying 17α-hydroxyprogesterone using immunoassay. However, this test produces high rates of false positive results caused by cross reacting steroids. Therefore we have developed a selective and specific method with a short run time (1.25 min) for quantification of 17α-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, 11-deoxycorticosterone and cortisol from dried blood spots. The extraction procedure is very simple and steroid separation is ensured on a BEH C18 column and an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Analysis was done in positive ionization mode (ESI+) and recorded in multiple reaction monitoring mode (MRM). The method gave linear results for all steroids over a range of 5-200 (cortisol: 12.5-500)nmol/L with coefficients of regression >0.992. Absolute recovery was >64.1%. Across the analytical range the inter-assay coefficient of variation (CV) was <3%. Newborn blood samples of patients with confirmed 21-CAH and 11-CAH could clearly be distinguished from samples of unaffected newborns falsely positive on immunoassay. The method is not influenced by cross reactions as found on immunoassay. Analysis of dried blood spots shows that this method is sensitive and fast enough to allow rapid analysis and can therefore improve the newborn screening program. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Quantitative LC-MS/MS analysis of seven ginsenosides and three aconitum alkaloids in Shen-Fu decoction

    PubMed Central

    2013-01-01

    Background Shen-Fu decoction is a traditional Chinese medicine prescription with a 3:2 ratio of Radix Ginseng and Fuzi (Radix Aconiti lateralis praeparata). Ginsenosides and alkaloids are considered to be the main active components of Shen-Fu decoction. However, no analytical methods have been used to quantitatively analyse both components in Shen-Fu decoction simultaneously. Results We successfully developed a rapid resolution liquid chromatography coupled with tandem mass spectrometry (RRLC-MS/MS) method for the simultaneous analysis of seven ginsenosides and three aconitum alkaloids in Shen-Fu decoction, the decoction of Radix ginseng and Fuzi (Radix Aconiti lateralis praeparata). Chromatogrpahic separation by RPLC was achieved using a reversed-phase column and a water/acetonitrile mobile phase, containing 0.05% formic acid and using a gradient system. The method was optimized to allow for simultaneous analysis of all analytes in 11minutes without the need for baseline resolution of the components. Furthermore, the separation demonstrated good linearity (r > 0.9882), repeatability (RSD < 7.01%), intra- and inter-day precisions (RSD < 5.06%) and high yields of recovery (91.13-111.97%) for ten major constituents, namely ginsenoside-Re, Rg1, Rb1, Rc, Rb2, Rd, Rf, aconitine, hypacoitine and mesaconitine. Conclusions The developed method could be used as a rapid and reliable approach for assessment of the quantity of the major constituents in Shen-Fu decoction. PMID:24107599

  17. A novel radio-tolerant astaxanthin-producing bacterium reveals a new astaxanthin derivative: astaxanthin dirhamnoside.

    PubMed

    Asker, Dalal; Awad, Tarek S; Beppu, Teruhiko; Ueda, Kenji

    2012-01-01

    Astaxanthin is a red ketocarotenoid that exhibits extraordinary health-promoting activities such as antioxidant, anti-inflammatory, antitumor, and immune booster. The recent discovery of the beneficial roles of astaxanthin against many degenerative diseases such as cancers, heart diseases, and exercise-induced fatigue has raised its market demand as a nutraceutical and medicinal ingredient in aquaculture, food, and pharmaceutical industries. To satisfy the growing demand for this high-value nutraceuticals ingredient and consumer interest in natural products, many research efforts are being made to discover novel microbial producers with effective biotechnological production of astaxanthin. Using a rapid screening method based on 16S rRNA gene, and effective HPLC-Diodearray-MS methods for carotenoids analysis, we succeeded to isolate a unique astaxanthin-producing bacterium (strain TDMA-17(T)) that belongs to the family Sphingomonadaceae (Asker et al., Appl Microbiol Biotechnol 77: 383-392, 2007). In this chapter, we provide a detailed description of effective HPLC-Diodearray-MS methods for rapid analysis and identification of the carotenoids produced by strain TDMA-17(T). We also describe the methods of isolation and identification for a novel bacterial carotenoid (astaxanthin derivative), a major carotenoid that is produced by strain TDMA-17(T). Finally, we describe the polyphasic taxonomic analysis of strain TDMA-17(T) and the description of a novel species belonging to genus Sphingomonas.

  18. Rapid analysis of pesticide residues in drinking water samples by dispersive solid-phase extraction based on multiwalled carbon nanotubes and pulse glow discharge ion source ion mobility spectrometry.

    PubMed

    Zou, Nan; Gu, Kejia; Liu, Shaowen; Hou, Yanbing; Zhang, Jialei; Xu, Xiang; Li, Xuesheng; Pan, Canping

    2016-03-01

    An analytical method based on dispersive solid-phase extraction with a multiwalled carbon nanotubes sorbent coupled with positive pulse glow discharge ion mobility spectrometry was developed for analysis of 30 pesticide residues in drinking water samples. Reduced ion mobilities and the mass-mobility correlation of 30 pesticides were measured. The pesticides were divided into five groups to verify the separation capability of pulse glow discharge in mobility spectrometry. The extraction conditions such as desorption solvent, ionic strength, conditions of adsorption and desorption, the amounts of multiwalled carbon nanotubes, and solution pH were optimized. The enrichment factors of pesticides were 5.4- to 48.7-fold (theoretical enrichment factor was 50-fold). The detection limits of pesticides were 0.01∼0.77 μg/kg. The linear range was 0.005-0.2 mg/L for pesticide standard solutions, with determination coefficients from 0.9616 to 0.9999. The method was applied for the analysis of practical and spiked drinking water samples. All results were confirmed by high-performance liquid chromatography with tandem mass spectrometry. The proposed method was proven to be a commendably rapid screening qualitative and semiquantitative technique for the analysis of pesticide residues in drinking water samples on site. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Monitoring cell culture media degradation using surface enhanced Raman scattering (SERS) spectroscopy.

    PubMed

    Calvet, Amandine; Ryder, Alan G

    2014-08-20

    The quality of the cell culture media used in biopharmaceutical manufacturing is a crucial factor affecting bioprocess performance and the quality of the final product. Due to their complex composition these media are inherently unstable, and significant compositional variations can occur particularly when in the prepared liquid state. For example photo-degradation of cell culture media can have adverse effects on cell viability and thus process performance. There is therefore, from quality control, quality assurance and process management view points, an urgent demand for the development of rapid and inexpensive tools for the stability monitoring of these complex mixtures. Spectroscopic methods, based on fluorescence or Raman measurements, have now become viable alternatives to more time-consuming and expensive (on a unit analysis cost) chromatographic and/or mass spectrometry based methods for routine analysis of media. Here we demonstrate the application of surface enhanced Raman scattering (SERS) spectroscopy for the simple, fast, analysis of cell culture media degradation. Once stringent reproducibility controls are implemented, chemometric data analysis methods can then be used to rapidly monitor the compositional changes in chemically defined media. SERS shows clearly that even when media are stored at low temperature (2-8°C) and in the dark, significant chemical changes occur, particularly with regard to cysteine/cystine concentration. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Microwell Array Method for Rapid Generation of Uniform Agarose Droplets and Beads for Single Molecule Analysis.

    PubMed

    Li, Xingrui; Zhang, Dongfeng; Zhang, Huimin; Guan, Zhichao; Song, Yanling; Liu, Ruochen; Zhu, Zhi; Yang, Chaoyong

    2018-02-20

    Compartmentalization of aqueous samples in uniform emulsion droplets has proven to be a useful tool for many chemical, biological, and biomedical applications. Herein, we introduce an array-based emulsification method for rapid and easy generation of monodisperse agarose-in-oil droplets in a PDMS microwell array. The microwells are filled with agarose solution, and subsequent addition of hot oil results in immediate formation of agarose droplets due to the surface-tension of the liquid solution. Because droplet size is determined solely by the array unit dimensions, uniform droplets with preselectable diameters ranging from 20 to 100 μm can be produced with relative standard deviations less than 3.5%. The array-based droplet generation method was used to perform digital PCR for absolute DNA quantitation. The array-based droplet isolation and sol-gel switching property of agarose enable formation of stable beads by chilling the droplet array at -20 °C, thus, maintaining the monoclonality of each droplet and facilitating the selective retrieval of desired droplets. The monoclonality of droplets was demonstrated by DNA sequencing and FACS analysis, suggesting the robustness and flexibility of the approach for single molecule amplification and analysis. We believe our approach will lead to new possibilities for a great variety of applications, such as single-cell gene expression studies, aptamer selection, and oligonucleotide analysis.

  1. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    PubMed

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    PubMed

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Rapid and accurate prediction of degradant formation rates in pharmaceutical formulations using high-performance liquid chromatography-mass spectrometry.

    PubMed

    Darrington, Richard T; Jiao, Jim

    2004-04-01

    Rapid and accurate stability prediction is essential to pharmaceutical formulation development. Commonly used stability prediction methods include monitoring parent drug loss at intended storage conditions or initial rate determination of degradants under accelerated conditions. Monitoring parent drug loss at the intended storage condition does not provide a rapid and accurate stability assessment because often <0.5% drug loss is all that can be observed in a realistic time frame, while the accelerated initial rate method in conjunction with extrapolation of rate constants using the Arrhenius or Eyring equations often introduces large errors in shelf-life prediction. In this study, the shelf life prediction of a model pharmaceutical preparation utilizing sensitive high-performance liquid chromatography-mass spectrometry (LC/MS) to directly quantitate degradant formation rates at the intended storage condition is proposed. This method was compared to traditional shelf life prediction approaches in terms of time required to predict shelf life and associated error in shelf life estimation. Results demonstrated that the proposed LC/MS method using initial rates analysis provided significantly improved confidence intervals for the predicted shelf life and required less overall time and effort to obtain the stability estimation compared to the other methods evaluated. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association.

  4. Investigation of prediction methods for the loads and stresses of Apollo type spacecraft parachutes. Volume 1: Loads

    NASA Technical Reports Server (NTRS)

    Mickey, F. E.; Mcewan, A. J.; Ewing, E. G.; Huyler, W. C., Jr.; Khajeh-Nouri, B.

    1970-01-01

    An analysis was conducted with the objective of upgrading and improving the loads, stress, and performance prediction methods for Apollo spacecraft parachutes. The subjects considered were: (1) methods for a new theoretical approach to the parachute opening process, (2) new experimental-analytical techniques to improve the measurement of pressures, stresses, and strains in inflight parachutes, and (3) a numerical method for analyzing the dynamical behavior of rapidly loaded pilot chute risers.

  5. Pipe leak diagnostic using high frequency piezoelectric pressure sensor and automatic selection of intrinsic mode function

    NASA Astrophysics Data System (ADS)

    Yusop, Hanafi M.; Ghazali, M. F.; Yusof, M. F. M.; Remli, M. A. Pi; Kamarulzaman, M. H.

    2017-10-01

    In a recent study, the analysis of pressure transient signals could be seen as an accurate and low-cost method for leak and feature detection in water distribution systems. Transient phenomena occurs due to sudden changes in the fluid’s propagation in pipelines system caused by rapid pressure and flow fluctuation due to events such as closing and opening valves rapidly or through pump failure. In this paper, the feasibility of the Hilbert-Huang transform (HHT) method/technique in analysing the pressure transient signals in presented and discussed. HHT is a way to decompose a signal into intrinsic mode functions (IMF). However, the advantage of HHT is its difficulty in selecting the suitable IMF for the next data postprocessing method which is Hilbert Transform (HT). This paper reveals that utilizing the application of an integrated kurtosis-based algorithm for a z-filter technique (I-Kaz) to kurtosis ratio (I-Kaz-Kurtosis) allows/contributes to/leads to automatic selection of the IMF that should be used. This technique is demonstrated on a 57.90-meter medium high-density polyethylene (MDPE) pipe installed with a single artificial leak. The analysis results using the I-Kaz-kurtosis ratio revealed/confirmed that the method can be used as an automatic selection of the IMF although the noise level ratio of the signal is low. Therefore, the I-Kaz-kurtosis ratio method is recommended as a means to implement an automatic selection technique of the IMF for HHT analysis.

  6. Multiresidue pesticide analysis of tuber and root commodities by QuEchERS extraction and ultra-performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Garrido Frenich, Antonia; Martín Fernández, María del Mar; Díaz Moreno, Laura; Martínez Vidal, Jose Lúis; López-Gutiérrez, Noelia

    2012-01-01

    A simple, rapid, and reliable multiresidue method to determine 84 pesticides in potato and carrot samples by ultra-performance liquid chromatography coupled to MS/MS has been developed and fully validated for routine analysis according to ISO/IEC 17025:2005. The method makes use of a buffered Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) sample preparation procedure based on a single extraction with acidified acetonitrile, followed by partitioning with salts. Chromatographic conditions were optimized in order to achieve a rapid separation in the multiple reaction monitoring mode. Performance characteristics of the method, including an estimation of measurement uncertainty using validation data, are reported for both matrixes. Calibration curves were linear from 0.010 to 0.150 mg/kg for most compounds. The LOD and LOQ were 0.006 and 0.010 mg/kg, respectively, except for fluorocloridone, fluquinconazol, and hexitiazox, which were 0.030 and 0.050 mg/kg, respectively. Recoveries obtained were in the range 70-116%, with intraday precision values < or = 20% RSD and interday precision values < or = 25% RSD at two different concentration levels. The overall uncertainty of the method was estimated at two concentrations as being lower than 34% in all cases. The method has been applied to the analysis of 70 vegetable samples, and imidacloprid and linuron were the pesticides most frequently found in potato and carrot commodities, respectively.

  7. High-Resolution Melting-Curve Analysis of Ligation-Mediated Real-Time PCR for Rapid Evaluation of an Epidemiological Outbreak of Extended-Spectrum-Beta-Lactamase-Producing Escherichia coli ▿

    PubMed Central

    Woksepp, Hanna; Jernberg, Cecilia; Tärnberg, Maria; Ryberg, Anna; Brolund, Alma; Nordvall, Michaela; Olsson-Liljequist, Barbro; Wisell, Karin Tegmark; Monstein, Hans-Jürg; Nilsson, Lennart E.; Schön, Thomas

    2011-01-01

    Methods for the confirmation of nosocomial outbreaks of bacterial pathogens are complex, expensive, and time-consuming. Recently, a method based on ligation-mediated PCR (LM/PCR) using a low denaturation temperature which produces specific melting-profile patterns of DNA products has been described. Our objective was to further develop this method for real-time PCR and high-resolution melting analysis (HRM) in a single-tube system optimized in order to achieve results within 1 day. Following the optimization of LM/PCR for real-time PCR and HRM (LM/HRM), the method was applied for a nosocomial outbreak of extended-spectrum-beta-lactamase (ESBL)-producing and ST131-associated Escherichia coli isolates (n = 15) and control isolates (n = 29), including four previous clusters. The results from LM/HRM were compared to results from pulsed-field gel electrophoresis (PFGE), which served as the gold standard. All isolates from the nosocomial outbreak clustered by LM/HRM, which was confirmed by gel electrophoresis of the LM/PCR products and PFGE. Control isolates that clustered by LM/PCR (n = 4) but not by PFGE were resolved by confirmatory gel electrophoresis. We conclude that LM/HRM is a rapid method for the detection of nosocomial outbreaks of bacterial infections caused by ESBL-producing E. coli strains. It allows the analysis of isolates in a single-tube system within a day, and the discriminatory power is comparable to that of PFGE. PMID:21956981

  8. High-resolution melting-curve analysis of ligation-mediated real-time PCR for rapid evaluation of an epidemiological outbreak of extended-spectrum-beta-lactamase-producing Escherichia coli.

    PubMed

    Woksepp, Hanna; Jernberg, Cecilia; Tärnberg, Maria; Ryberg, Anna; Brolund, Alma; Nordvall, Michaela; Olsson-Liljequist, Barbro; Wisell, Karin Tegmark; Monstein, Hans-Jürg; Nilsson, Lennart E; Schön, Thomas

    2011-12-01

    Methods for the confirmation of nosocomial outbreaks of bacterial pathogens are complex, expensive, and time-consuming. Recently, a method based on ligation-mediated PCR (LM/PCR) using a low denaturation temperature which produces specific melting-profile patterns of DNA products has been described. Our objective was to further develop this method for real-time PCR and high-resolution melting analysis (HRM) in a single-tube system optimized in order to achieve results within 1 day. Following the optimization of LM/PCR for real-time PCR and HRM (LM/HRM), the method was applied for a nosocomial outbreak of extended-spectrum-beta-lactamase (ESBL)-producing and ST131-associated Escherichia coli isolates (n = 15) and control isolates (n = 29), including four previous clusters. The results from LM/HRM were compared to results from pulsed-field gel electrophoresis (PFGE), which served as the gold standard. All isolates from the nosocomial outbreak clustered by LM/HRM, which was confirmed by gel electrophoresis of the LM/PCR products and PFGE. Control isolates that clustered by LM/PCR (n = 4) but not by PFGE were resolved by confirmatory gel electrophoresis. We conclude that LM/HRM is a rapid method for the detection of nosocomial outbreaks of bacterial infections caused by ESBL-producing E. coli strains. It allows the analysis of isolates in a single-tube system within a day, and the discriminatory power is comparable to that of PFGE.

  9. Validation of a rapid bacteria endospore enumeration system for use with spacecraft assembly

    NASA Astrophysics Data System (ADS)

    Chen, F.; Kuhlman, G.; Kirschner, L.; Kazarians, G.; Matsuyama, A.; Pickett, M.; Venkateswaran, K.; Kastner, J.; Kern, R.

    NASA planetary protection policy sets forth strict limits on the number of bacterial endospores that can be present on a spacecraft at launch Currently the only approved method for counting the spores is a culture based assay that requires three days to produce results a timeframe that can be at odds with the rapid pace and rigorous deadlines of spacecraft assembly A possible alternative to the traditional culture based approach is the Millipore Rapid Microbiology Detection System RMDS which has previously been used for process and contamination control in the pharmaceutical and food industries The RMDS is rapid and simple shows high sensitivity 1 colony forming unit CFU sample and correlates well with traditional culture-based methods It combines membrane filtration adenosine triphosphate ATP bioluminescence chemistry and image analysis based on photon detection with a Charge Coupled Device CCD camera In this study we have optimized the assay condition and evaluated the use of the RMDS as a rapid spore detection tool for NASA applications Seven species of Bacillus nine strains that have been repeatedly isolated from clean room environments were assayed In order to select for spores the samples were subjected to a heat shock step before proceeding with the RMDS incubation protocol All strains were detected by the RMDS in sim 5 hours and these assay times were repeatedly demonstrated along with low image background noise The RMDS-based spore detection method is undergoing the final stages of validation and is

  10. Quality evaluation of fish and other seafood by traditional and nondestructive instrumental methods: Advantages and limitations.

    PubMed

    Hassoun, Abdo; Karoui, Romdhane

    2017-06-13

    Although being one of the most vulnerable and perishable products, fish and other seafoods provide a wide range of health-promoting compounds. Recently, the growing interest of consumers in food quality and safety issues has contributed to the increasing demand for sensitive and rapid analytical technologies. Several traditional physicochemical, textural, sensory, and electrical methods have been used to evaluate freshness and authentication of fish and other seafood products. Despite the importance of these standard methods, they are expensive and time-consuming, and often susceptible to large sources of variation. Recently, spectroscopic methods and other emerging techniques have shown great potential due to speed of analysis, minimal sample preparation, high repeatability, low cost, and, most of all, the fact that these techniques are noninvasive and nondestructive and, therefore, could be applied to any online monitoring system. This review describes firstly and briefly the basic principles of multivariate data analysis, followed by the most commonly traditional methods used for the determination of the freshness and authenticity of fish and other seafood products. A special focus is put on the use of rapid and nondestructive techniques (spectroscopic techniques and instrumental sensors) to address several issues related to the quality of these products. Moreover, the advantages and limitations of each technique are reviewed and some perspectives are also given.

  11. Comparison of allele-specific PCR, created restriction-site PCR, and PCR with primer-introduced restriction analysis methods used for screening complex vertebral malformation carriers in Holstein cattle

    PubMed Central

    Altınel, Ahmet

    2017-01-01

    Complex vertebral malformation (CVM) is an inherited, autosomal recessive disorder of Holstein cattle. The aim of this study was to compare sensitivity, specificity, positive and negative predictive values, accuracy, and rapidity of allele-specific polymerase chain reaction (AS-PCR), created restriction-site PCR (CRS-PCR), and PCR with primer-introduced restriction analysis (PCR-PIRA), three methods used in identification of CVM carriers in a Holstein cattle population. In order to screen for the G>T mutation in the solute carrier family 35 member A3 (SLC35A3) gene, DNA sequencing as the gold standard method was used. The prevalence of carriers and the mutant allele frequency were 3.2% and 0.016, respectively, among Holstein cattle in the Thrace region of Turkey. Among the three methods, the fastest but least accurate was AS-PCR. Although the rapidity of CRS-PCR and PCR-PIRA were nearly equal, the accuracy of PCR-PIRA was higher than that of CRS-PCR. Therefore, among the three methods, PCR-PIRA appears to be the most efficacious for screening of mutant alleles when identifying CVM carriers in a Holstein cattle population. PMID:28927256

  12. Development and validation of a sensitive HPLC method for the quantification of HI-6 in guinea pig plasma and evaluated in domestic swine.

    PubMed

    Bohnert, Sara; Vair, Cory; Mikler, John

    2010-05-15

    A rapid and small volume assay to quantify HI-6 in plasma was developed to further the development and licensing of an intravenous formulation of HI-6. The objective of this method was to develop a sensitive and rapid assay that clearly resolved HI-6 and an internal standard in saline and plasma matrices. A fully validated method using ion-pair HPLC and 2-PAM as the internal standard fulfilled these requirements. Small plasma samples of 35 microL were extracted using acidification, filtration and neutralization. Linearity was shown for over 4 microg/mL to 1mg/mL with accuracy and precision within 6% relative error at the lower limit of detection. This method was utilized in the pharmacokinetic analysis HI-6 dichloride (2Cl) and HI-6 dimethane sulfonate (DMS) in anaesthetized guinea pigs and domestic swine following an intravenous bolus administration. From the resultant pharmacokinetic parameters a target plasma concentration of 100 microM was established and maintained in guinea pigs receiving an intravenous infusion. This validated method allows for the analysis of low volume samples, increased sample numbers and is applicable to the determination of pharmacokinetic profiles and parameters. Copyright (c) 2010. Published by Elsevier B.V.

  13. Development and Single-Laboratory Validation of a Liquid Chromatography Tandem Mass Spectrometry Method for Quantitation of Tetrodotoxin in Mussels and Oysters.

    PubMed

    Turner, Andrew D; Boundy, Michael J; Rapkova, Monika Dhanji

    2017-09-01

    In recent years, evidence has grown for the presence of tetrodotoxin (TTX) in bivalve mollusks, leading to the potential for consumers of contaminated products to be affected by Tetrodotoxin Shellfish Poisoning (TSP). A single-laboratory validation was conducted for the hydrophilic interaction LC (HILIC) tandem MS (MS/MS) analysis of TTX in common mussels and Pacific oysters-the bivalve species that have been found to contain TTXs in the United Kingdom in recent years. The method consists of a single-step dispersive extraction in 1% acetic acid, followed by a carbon SPE cleanup step before dilution and instrumental analysis. The full method was developed as a rapid tool for the quantitation of TTX, as well as for the associated analogs 4-epi-TTX; 5,6,11-trideoxy TTX; 11-nor TTX-6-ol; 5-deoxy TTX; and 4,9-anhydro TTX. The method can also be run as the acquisition of TTX together with paralytic shellfish toxins. Results demonstrated acceptable method performance characteristics for specificity, linearity, recovery, ruggedness, repeatability, matrix variability, and within-laboratory reproducibility for the analysis of TTX. The LOD and LOQ were fit-for-purpose in comparison to the current action limit for TTX enforced in The Netherlands. In addition, aspects of method performance (LOD, LOQ, and within-laboratory reproducibility) were found to be satisfactory for three other TTX analogs (11-nor TTX-6-ol, 5-deoxy TTX, and 4,9-anhydro TTX). The method was found to be practical and suitable for use in regulatory testing, providing rapid turnaround of sample analysis. Plans currently underway on a full collaborative study to validate a HILIC-MS/MS method for paralytic shellfish poisoning toxins will be extended to include TTX in order to generate international acceptance, ultimately for use as an alternative official control testing method should regulatory controls be adopted.

  14. Determination of Diethyl Phthalate and Polyhexamethylene Guanidine in Surrogate Alcohol from Russia

    PubMed Central

    Monakhova, Yulia B.; Kuballa, Thomas; Leitz, Jenny; Lachenmeier, Dirk W.

    2011-01-01

    Analytical methods based on spectroscopic techniques were developed and validated for the determination of diethyl phthalate (DEP) and polyhexamethylene guanidine (PHMG), which may occur in unrecorded alcohol. Analysis for PHMG was based on UV-VIS spectrophotometry after derivatization with Eosin Y and 1H NMR spectroscopy of the DMSO extract. Analysis of DEP was performed with direct UV-VIS and 1H NMR methods. Multivariate curve resolution and spectra computation methods were used to confirm the presence of PHMG and DEP in the investigated beverages. Of 22 analysed alcohol samples, two contained DEP or PHMG. 1H NMR analysis also revealed the presence of signals of hawthorn extract in three medicinal alcohols used as surrogate alcohol. The simple and cheap UV-VIS methods can be used for rapid screening of surrogate alcohol samples for impurities, while 1H NMR is recommended for specific confirmatory analysis if required. PMID:21647285

  15. Determination of diethyl phthalate and polyhexamethylene guanidine in surrogate alcohol from Russia.

    PubMed

    Monakhova, Yulia B; Kuballa, Thomas; Leitz, Jenny; Lachenmeier, Dirk W

    2011-01-01

    Analytical methods based on spectroscopic techniques were developed and validated for the determination of diethyl phthalate (DEP) and polyhexamethylene guanidine (PHMG), which may occur in unrecorded alcohol. Analysis for PHMG was based on UV-VIS spectrophotometry after derivatization with Eosin Y and (1)H NMR spectroscopy of the DMSO extract. Analysis of DEP was performed with direct UV-VIS and (1)H NMR methods. Multivariate curve resolution and spectra computation methods were used to confirm the presence of PHMG and DEP in the investigated beverages. Of 22 analysed alcohol samples, two contained DEP or PHMG. (1)H NMR analysis also revealed the presence of signals of hawthorn extract in three medicinal alcohols used as surrogate alcohol. The simple and cheap UV-VIS methods can be used for rapid screening of surrogate alcohol samples for impurities, while (1)H NMR is recommended for specific confirmatory analysis if required.

  16. Analysis of Glycosaminoglycans Using Mass Spectrometry

    PubMed Central

    Staples, Gregory O.; Zaia, Joseph

    2015-01-01

    The glycosaminoglycans (GAGs) are linear polysaccharides expressed on animal cell surfaces and in extracellular matrices. Their biosynthesis is under complex control and confers a domain structure that is essential to their ability to bind to protein partners. Key to understanding the functions of GAGs are methods to determine accurately and rapidly patterns of sulfation, acetylation and uronic acid epimerization that correlate with protein binding or other biological activities. Mass spectrometry (MS) is particularly suitable for the analysis of GAGs for biomedical purposes. Using modern ionization techniques it is possible to accurately determine molecular weights of GAG oligosaccharides and their distributions within a mixture. Methods for direct interfacing with liquid chromatography have been developed to permit online mass spectrometric analysis of GAGs. New tandem mass spectrometric methods for fine structure determination of GAGs are emerging. This review summarizes MS-based approaches for analysis of GAGs, including tissue extraction and chromatographic methods compatible with LC/MS and tandem MS. PMID:25705143

  17. Enterprise architecture availability analysis using fault trees and stakeholder interviews

    NASA Astrophysics Data System (ADS)

    Närman, Per; Franke, Ulrik; König, Johan; Buschle, Markus; Ekstedt, Mathias

    2014-01-01

    The availability of enterprise information systems is a key concern for many organisations. This article describes a method for availability analysis based on Fault Tree Analysis and constructs from the ArchiMate enterprise architecture (EA) language. To test the quality of the method, several case-studies within the banking and electrical utility industries were performed. Input data were collected through stakeholder interviews. The results from the case studies were compared with availability of log data to determine the accuracy of the method's predictions. In the five cases where accurate log data were available, the yearly downtime estimates were within eight hours from the actual downtimes. The cost of performing the analysis was low; no case study required more than 20 man-hours of work, making the method ideal for practitioners with an interest in obtaining rapid availability estimates of their enterprise information systems.

  18. Rapid and sensitive detection of malachite green in aquaculture water by electrochemical preconcentration and surface-enhanced Raman scattering.

    PubMed

    Xu, Kai-Xuan; Guo, Mei-Hong; Huang, Yu-Ping; Li, Xiao-Dong; Sun, Jian-Jun

    2018-04-01

    A highly sensitive and rapid method of in-situ surface-enhanced Raman spectroscopy (SERS) combining with electrochemical preconcentration (EP) in detecting malachite green (MG) in aquaculture water was established. Ag nanoparticles (AgNPs) were synthesized and spread onto the surface of gold electrodes after centrifuging to produce SERS-active substrates. After optimizing the pH values, preconcentration potentials and times, in-situ EP-SERS detection was carried out. A sensitive and rapid analysis of the low-concentration MG was accomplished within 200s and the limit of detection was 2.4 × 10 -16 M. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A method for the automated detection phishing websites through both site characteristics and image analysis

    NASA Astrophysics Data System (ADS)

    White, Joshua S.; Matthews, Jeanna N.; Stacy, John L.

    2012-06-01

    Phishing website analysis is largely still a time-consuming manual process of discovering potential phishing sites, verifying if suspicious sites truly are malicious spoofs and if so, distributing their URLs to the appropriate blacklisting services. Attackers increasingly use sophisticated systems for bringing phishing sites up and down rapidly at new locations, making automated response essential. In this paper, we present a method for rapid, automated detection and analysis of phishing websites. Our method relies on near real-time gathering and analysis of URLs posted on social media sites. We fetch the pages pointed to by each URL and characterize each page with a set of easily computed values such as number of images and links. We also capture a screen-shot of the rendered page image, compute a hash of the image and use the Hamming distance between these image hashes as a form of visual comparison. We provide initial results demonstrate the feasibility of our techniques by comparing legitimate sites to known fraudulent versions from Phishtank.com, by actively introducing a series of minor changes to a phishing toolkit captured in a local honeypot and by performing some initial analysis on a set of over 2.8 million URLs posted to Twitter over a 4 days in August 2011. We discuss the issues encountered during our testing such as resolvability and legitimacy of URL's posted on Twitter, the data sets used, the characteristics of the phishing sites we discovered, and our plans for future work.

  20. EPIBLASTER-fast exhaustive two-locus epistasis detection strategy using graphical processing units

    PubMed Central

    Kam-Thong, Tony; Czamara, Darina; Tsuda, Koji; Borgwardt, Karsten; Lewis, Cathryn M; Erhardt-Lehmann, Angelika; Hemmer, Bernhard; Rieckmann, Peter; Daake, Markus; Weber, Frank; Wolf, Christiane; Ziegler, Andreas; Pütz, Benno; Holsboer, Florian; Schölkopf, Bernhard; Müller-Myhsok, Bertram

    2011-01-01

    Detection of epistatic interaction between loci has been postulated to provide a more in-depth understanding of the complex biological and biochemical pathways underlying human diseases. Studying the interaction between two loci is the natural progression following traditional and well-established single locus analysis. However, the added costs and time duration required for the computation involved have thus far deterred researchers from pursuing a genome-wide analysis of epistasis. In this paper, we propose a method allowing such analysis to be conducted very rapidly. The method, dubbed EPIBLASTER, is applicable to case–control studies and consists of a two-step process in which the difference in Pearson's correlation coefficients is computed between controls and cases across all possible SNP pairs as an indication of significant interaction warranting further analysis. For the subset of interactions deemed potentially significant, a second-stage analysis is performed using the likelihood ratio test from the logistic regression to obtain the P-value for the estimated coefficients of the individual effects and the interaction term. The algorithm is implemented using the parallel computational capability of commercially available graphical processing units to greatly reduce the computation time involved. In the current setup and example data sets (211 cases, 222 controls, 299468 SNPs; and 601 cases, 825 controls, 291095 SNPs), this coefficient evaluation stage can be completed in roughly 1 day. Our method allows for exhaustive and rapid detection of significant SNP pair interactions without imposing significant marginal effects of the single loci involved in the pair. PMID:21150885

Top