Sample records for rapid assay method

  1. Evaluation of phage assay for rapid phenotypic detection of rifampicin resistance in Mycobacterium tuberculosis

    PubMed Central

    Yzquierdo, Sergio Luis; Lemus, Dihadenys; Echemendia, Miguel; Montoro, Ernesto; McNerney, Ruth; Martin, Anandi; Palomino, Juan Carlos

    2006-01-01

    Background Conventional methods for susceptibility testing require several months before results can be reported. However, rapid methods to determine drug susceptibility have been developed recently. Phage assay have been reported as a rapid useful tools for antimicrobial susceptibility testing. The aim of this study was to apply the Phage assay for rapid detection of resistance on Mycobacterium tuberculosis strains in Cuba. Methods Phage D29 assay was performed on 102 M. tuberculosis strains to detect rifampicin resistance. The results were compared with the proportion method (gold standard) to evaluate the sensitivity and specificity of Phage assay. Results Phage assay results were available in 2 days whereas Proportion Methods results were obtain in 42 days. A total of 44 strains were detected as rifampicin resistant by both methods. However, one strains deemed resistant by Proportion Methods was susceptible by Phage assay. The sensitivity and specificity of Phage assay were 97.8 % and 100% respectively. Conclusion Phage assay provides rapid and reliable results for susceptibility testing; it's easy to perform, requires no specialized equipment and is applicable to drug susceptibility testing in low income countries where tuberculosis is a major public health problem. PMID:16630356

  2. Validation of a Rapid Bacteria Endospore Enumeration System for Planetary Protection Application

    NASA Astrophysics Data System (ADS)

    Chen, Fei; Kern, Roger; Kazarians, Gayane; Venkateswaran, Kasthuri

    NASA monitors spacecraft surfaces to assure that the presence of bacterial endospores meets strict criteria at launch, to minimize the risk of inadvertent contamination of the surface of Mars. Currently, the only approved method for enumerating the spores is a culture based assay that requires three days to produce results. In order to meet the demanding schedules of spacecraft assembly, a more rapid spore detection assay is being considered as an alternate method to the NASA standard culture-based assay. The Millipore Rapid Microbiology Detection System (RMDS) has been used successfully for rapid bioburden enumeration in the pharmaceutical and food industries. The RMDS is rapid and simple, shows high sensitivity (to 1 colony forming unit [CFU]/sample), and correlates well with traditional culture-based methods. It combines membrane filtration, adenosine triphosphate (ATP) bioluminescence chemistry, and image analysis based on photon detection with a Charge Coupled Device (CCD) camera. In this study, we have optimized the assay conditions and evaluated the use of the RMDS as a rapid spore detection tool for NASA applications. In order to select for spores, the samples were subjected to a heat shock step before proceeding with the RMDS incubation protocol. Seven species of Bacillus (nine strains) that have been repeatedly isolated from clean room environments were assayed. All strains were detected by the RMDS in 5 hours and these assay times were repeatedly demonstrated along with low image background noise. Validation experiments to compare the Rapid Sore Assay (RSA) and NASA standard assay (NSA) were also performed. The evaluation criteria were modeled after the FDA Guideline of Process Validation, and Analytical Test Methods. This body of research demonstrates that the Rapid Spore Assay (RSA) is quick, and of equivalent sensitivity to the NASA standard assay, potentially reducing the assay time for bacterial endospores from over 72 hours to less than 8 hours. Accordingly, JPL has produced a report recommending that NASA adopt the RSA method as a suitable alternative to the NASA standard assay.

  3. Lead discovery for mammalian elongation of long chain fatty acids family 6 using a combination of high-throughput fluorescent-based assay and RapidFire mass spectrometry assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takamiya, Mari; Discovery Technology Laboratories, Sohyaku, Innovative Research Division, Mitsubishi Tanabe Pharma Corporation, Kawagishi, Toda-shi, Saitama; Sakurai, Masaaki

    A high-throughput RapidFire mass spectrometry assay is described for elongation of very long-chain fatty acids family 6 (Elovl6). Elovl6 is a microsomal enzyme that regulates the elongation of C12-16 saturated and monounsaturated fatty acids. Elovl6 may be a new therapeutic target for fat metabolism disorders such as obesity, type 2 diabetes, and nonalcoholic steatohepatitis. To identify new Elovl6 inhibitors, we developed a high-throughput fluorescence screening assay in 1536-well format. However, a number of false positives caused by fluorescent interference have been identified. To pick up the real active compounds among the primary hits from the fluorescence assay, we developed amore » RapidFire mass spectrometry assay and a conventional radioisotope assay. These assays have the advantage of detecting the main products directly without using fluorescent-labeled substrates. As a result, 276 compounds (30%) of the primary hits (921 compounds) in a fluorescence ultra-high-throughput screening method were identified as common active compounds in these two assays. It is concluded that both methods are very effective to eliminate false positives. Compared with the radioisotope method using an expensive {sup 14}C-labeled substrate, the RapidFire mass spectrometry method using unlabeled substrates is a high-accuracy, high-throughput method. In addition, some of the hit compounds selected from the screening inhibited cellular fatty acid elongation in HEK293 cells expressing Elovl6 transiently. This result suggests that these compounds may be promising lead candidates for therapeutic drugs. Ultra-high-throughput fluorescence screening followed by a RapidFire mass spectrometry assay was a suitable strategy for lead discovery against Elovl6. - Highlights: • A novel assay for elongation of very-long-chain fatty acids 6 (Elovl6) is proposed. • RapidFire mass spectrometry (RF-MS) assay is useful to select real screening hits. • RF-MS assay is proved to be beneficial because of its high-throughput and accuracy. • A combination of fluorescent and RF-MS assays is effective for Elovl6 inhibitors.« less

  4. Fundamentals of rapid injection molding for microfluidic cell-based assays.

    PubMed

    Lee, Ulri N; Su, Xiaojing; Guckenberger, David J; Dostie, Ashley M; Zhang, Tianzi; Berthier, Erwin; Theberge, Ashleigh B

    2018-01-30

    Microscale cell-based assays have demonstrated unique capabilities in reproducing important cellular behaviors for diagnostics and basic biological research. As these assays move beyond the prototyping stage and into biological and clinical research environments, there is a need to produce microscale culture platforms more rapidly, cost-effectively, and reproducibly. 'Rapid' injection molding is poised to meet this need as it enables some of the benefits of traditional high volume injection molding at a fraction of the cost. However, rapid injection molding has limitations due to the material and methods used for mold fabrication. Here, we characterize advantages and limitations of rapid injection molding for microfluidic device fabrication through measurement of key features for cell culture applications including channel geometry, feature consistency, floor thickness, and surface polishing. We demonstrate phase contrast and fluorescence imaging of cells grown in rapid injection molded devices and provide design recommendations to successfully utilize rapid injection molding methods for microscale cell-based assay development in academic laboratory settings.

  5. Optimisation and validation of a rapid and efficient microemulsion liquid chromatographic (MELC) method for the determination of paracetamol (acetaminophen) content in a suppository formulation.

    PubMed

    McEvoy, Eamon; Donegan, Sheila; Power, Joe; Altria, Kevin

    2007-05-09

    A rapid and efficient oil-in-water microemulsion liquid chromatographic method has been optimised and validated for the analysis of paracetamol in a suppository formulation. Excellent linearity, accuracy, precision and assay results were obtained. Lengthy sample pre-treatment/extraction procedures were eliminated due to the solubilising power of the microemulsion and rapid analysis times were achieved. The method was optimised to achieve rapid analysis time and relatively high peak efficiencies. A standard microemulsion composition of 33 g SDS, 66 g butan-1-ol, 8 g n-octane in 1l of 0.05% TFA modified with acetonitrile has been shown to be suitable for the rapid analysis of paracetamol in highly hydrophobic preparations under isocratic conditions. Validated assay results and overall analysis time of the optimised method was compared to British Pharmacopoeia reference methods. Sample preparation and analysis times for the MELC analysis of paracetamol in a suppository were extremely rapid compared to the reference method and similar assay results were achieved. A gradient MELC method using the same microemulsion has been optimised for the resolution of paracetamol and five of its related substances in approximately 7 min.

  6. Rationalizing and advancing the 3-MPBA SERS sandwich assay for rapid detection of bacteria in environmental and food matrices.

    PubMed

    Pearson, Brooke; Mills, Alexander; Tucker, Madeline; Gao, Siyue; McLandsborough, Lynne; He, Lili

    2018-06-01

    Bacterial foodborne illness continues to be a pressing issue in our food supply. Rapid detection methods are needed for perishable foods due to their short shelf lives and significant contribution to foodborne illness. Previously, a sensitive and reliable surface-enhanced Raman spectroscopy (SERS) sandwich assay based on 3-mercaptophenylboronic acid (3-MBPA) as a capturer and indicator molecule was developed for rapid bacteria detection. In this study, we explored the advantages and constraints of this assay over the conventional aerobic plate count (APC) method and further developed methods for detection in real environmental and food matrices. The SERS sandwich assay was able to detect environmental bacteria in pond water and on spinach leaves at higher levels than the APC method. In addition, the SERS assay appeared to have higher sensitivity to quantify bacteria in the stationary phase. On the other hand, the APC method was more sensitive to cell viability. Finally, a method to detect bacteria in a challenging high-sugar juice matrix was developed to enhance bacteria capture. This study advanced the SERS technique for real applications in environment and food matrices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid and Sensitive Identification of Ostrich Meat

    PubMed Central

    Abdulmawjood, Amir; Grabowski, Nils; Fohler, Svenja; Kittler, Sophie; Nagengast, Helga; Klein, Guenter

    2014-01-01

    Animal species identification is one of the primary duties of official food control. Since ostrich meat is difficult to be differentiated macroscopically from beef, therefore new analytical methods are needed. To enforce labeling regulations for the authentication of ostrich meat, it might be of importance to develop and evaluate a rapid and reliable assay. In the present study, a loop-mediated isothermal amplification (LAMP) assay based on the cytochrome b gene of the mitochondrial DNA of the species Struthio camelus was developed. The LAMP assay was used in combination with a real-time fluorometer. The developed system allowed the detection of 0.01% ostrich meat products. In parallel, a direct swab method without nucleic acid extraction using the HYPLEX LPTV buffer was also evaluated. This rapid processing method allowed detection of ostrich meat without major incubation steps. In summary, the LAMP assay had excellent sensitivity and specificity for detecting ostrich meat and could provide a sampling-to-result identification-time of 15 to 20 minutes. PMID:24963709

  8. Rapid Authentication of Ginkgo biloba Herbal Products Using the Recombinase Polymerase Amplification Assay.

    PubMed

    Liu, Yang; Wang, Xiao-Yue; Wei, Xue-Min; Gao, Zi-Tong; Han, Jian-Ping

    2018-05-22

    Species adulteration in herbal products (HPs) exposes consumers to health risks. Chemical and morphological methods have their own deficiencies when dealing with the detection of species containing the same active compounds in HPs. In this study, we developed a rapid identification method using the recombinase polymerase amplification (RPA) assay to detect two species, Ginkgo biloba and Sophora japonica (as adulteration), in Ginkgo biloba HPs. Among 36 Ginkgo biloba HP samples, 34 were found to have Ginkgo biloba sequences, and 9 were found to have Sophora japonica sequences. During the authentication process, the RPA-LFS assay showed a higher specificity, sensitivity and efficiency than PCR-based methods. We initially applied the RPA-LSF technique to detect plant species in HPs, demonstrating that this assay can be developed into an efficient tool for the rapid on-site authentication of plant species in Ginkgo biloba HPs.

  9. Rapid method for protein quantitation by Bradford assay after elimination of the interference of polysorbate 80.

    PubMed

    Cheng, Yongfeng; Wei, Haiming; Sun, Rui; Tian, Zhigang; Zheng, Xiaodong

    2016-02-01

    Bradford assay is one of the most common methods for measuring protein concentrations. However, some pharmaceutical excipients, such as detergents, interfere with Bradford assay even at low concentrations. Protein precipitation can be used to overcome sample incompatibility with protein quantitation. But the rate of protein recovery caused by acetone precipitation is only about 70%. In this study, we found that sucrose not only could increase the rate of protein recovery after 1 h acetone precipitation, but also did not interfere with Bradford assay. So we developed a method for rapid protein quantitation in protein drugs even if they contained interfering substances. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Validation of the Applied Biosystems RapidFinder Shiga Toxin-Producing E. coli (STEC) Detection Workflow.

    PubMed

    Cloke, Jonathan; Matheny, Sharon; Swimley, Michelle; Tebbs, Robert; Burrell, Angelia; Flannery, Jonathan; Bastin, Benjamin; Bird, Patrick; Benzinger, M Joseph; Crowley, Erin; Agin, James; Goins, David; Salfinger, Yvonne; Brodsky, Michael; Fernandez, Maria Cristina

    2016-11-01

    The Applied Biosystems™ RapidFinder™ STEC Detection Workflow (Thermo Fisher Scientific) is a complete protocol for the rapid qualitative detection of Escherichia coli (E. coli) O157:H7 and the "Big 6" non-O157 Shiga-like toxin-producing E. coli (STEC) serotypes (defined as serogroups: O26, O45, O103, O111, O121, and O145). The RapidFinder STEC Detection Workflow makes use of either the automated preparation of PCR-ready DNA using the Applied Biosystems PrepSEQ™ Nucleic Acid Extraction Kit in conjunction with the Applied Biosystems MagMAX™ Express 96-well magnetic particle processor or the Applied Biosystems PrepSEQ Rapid Spin kit for manual preparation of PCR-ready DNA. Two separate assays comprise the RapidFinder STEC Detection Workflow, the Applied Biosystems RapidFinder STEC Screening Assay and the Applied Biosystems RapidFinder STEC Confirmation Assay. The RapidFinder STEC Screening Assay includes primers and probes to detect the presence of stx1 (Shiga toxin 1), stx2 (Shiga toxin 2), eae (intimin), and E. coli O157 gene targets. The RapidFinder STEC Confirmation Assay includes primers and probes for the "Big 6" non-O157 STEC and E. coli O157:H7. The use of these two assays in tandem allows a user to detect accurately the presence of the "Big 6" STECs and E. coli O157:H7. The performance of the RapidFinder STEC Detection Workflow was evaluated in a method comparison study, in inclusivity and exclusivity studies, and in a robustness evaluation. The assays were compared to the U.S. Department of Agriculture (USDA), Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook (MLG) 5.09: Detection, Isolation and Identification of Escherichia coli O157:H7 from Meat Products and Carcass and Environmental Sponges for raw ground beef (73% lean) and USDA/FSIS-MLG 5B.05: Detection, Isolation and Identification of Escherichia coli non-O157:H7 from Meat Products and Carcass and Environmental Sponges for raw beef trim. No statistically significant differences were observed between the reference method and the individual or combined kits forming the candidate assay using either of the DNA preparation kits (manual or automated extraction). For the inclusivity and exclusivity evaluation, the RapidFinder STEC Detection Workflow, comprising both RapidFinder STEC screening and confirmation kits, correctly identified all 50 target organism isolates and correctly excluded all 30 nontarget strains for both of the assays evaluated. The results of these studies demonstrate the sensitivity and selectivity of the RapidFinder STEC Detection Workflow for the detection of E. coli O157:H7 and the "Big 6" STEC serotypes in both raw ground beef and beef trim. The robustness testing demonstrated that minor variations in the method parameters did not impact the accuracy of the assay and highlighted the importance of following the correct incubation temperatures.

  11. A colorimetric assay of 1-aminocyclopropane-1-carboxylate (ACC) based on ninhydrin reaction for rapid screening of bacteria containing ACC deaminase.

    PubMed

    Li, Z; Chang, S; Lin, L; Li, Y; An, Q

    2011-08-01

    1-Aminocyclopropane-1-carboxylate (ACC) deaminase activity is an efficient marker for bacteria to promote plant growth by lowering ethylene levels in plants. We aim to develop a method for rapidly screening bacteria containing ACC deaminase, based on a colorimetric ninhydrin assay of ACC. A reliable colorimetric ninhydrin assay was developed to quantify ACC using heat-resistant polypropylene chimney-top 96-well PCR plates, having the wells evenly heated in boiling water, preventing accidental contamination from boiling water and limiting evaporation. With this method to measure bacterial consumption of ACC, 44 ACC-utilizing bacterial isolates were rapidly screened out from 311 bacterial isolates that were able to grow on minimal media containing ACC as the sole nitrogen source. The 44 ACC-utilizing bacterial isolates showed ACC deaminase activities and belonged to the genus Burkholderia, Pseudomonas or Herbaspirillum. Determination of bacterial ACC consumption by the PCR-plate ninhydrin-ACC assay is a rapid and efficient method for screening bacteria containing ACC deaminase from a large number of bacterial isolates. The PCR-plate ninhydrin-ACC assay extends the utility of the ninhydrin reaction and enables a rapid screening of bacteria containing ACC deaminase from large numbers of bacterial isolates. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  12. Rapid mycobacteria drug susceptibility testing using Gel Microdrop (GMD) Growth Assay and flow cytometry.

    PubMed

    Akselband, Y; Cabral, C; Shapiro, D S; McGrath, P

    2005-08-01

    Control of multi-drug-resistant tuberculosis has been hampered by the lack of simple, rapid and sensitive methods for assessing bacterial growth and antimicrobial susceptibility. Due to the increasing incidence and high frequency of mutations, it is unlikely that culture methods will disappear in the foreseeable future. Therefore, the need to modernize methods for rapid detection of viable clinical isolates, at a minimum as a gold standard, will persist. Previously, we confirmed the feasibility of using the Gel Microdrop (GMD) Growth Assay for identifying sub-populations of resistant Mycobacteria by testing different laboratory strains. Briefly, this assay format relies on encapsulating single bacterium in agarose microspheres and identifying clonogenic growth using flow cytometry and fluorescent staining. In this study, we modified the GMD Growth Assay to make it suitable for clinical applications. We demonstrated the effectiveness and safety of this novel approach for detecting drug susceptibility in clinically relevant laboratory strains as well as clinical isolates of Mycobacterium tuberculosis. Correlation between results using the GMD Growth Assay format and results using two well characterized methods (Broth Microdilution MIC and BACTEC 460TB) was 87.5% and 90%, respectively. However, due to the inherent sensitivity of flow cytometry and the ability to detect small (<1%) sub-populations of resistant mycobacteria, the GMD Growth Assay identified more cases of drug resistance. Using 4 clinically relevant mycobacterial strains, we assessed susceptibility to primary anti-tuberculosis drugs using both the Broth Microdilution MIC method and the GMD Growth Assay. We performed 24 tests on isoniazid-resistant BCG, Mycobacterium tuberculosis H37Ra and Mycobacterium avium strains. The Broth Microdilution MIC method identified 7 cases (29.1%) of resistance to INH and EMB compared to the GMD Growth Assay which identified resistance in 10 cases (41.6%); in 3 cases (12.5%), resistance to INH and EMB was detected only with the GMD Growth Assay. In addition, using 20 Mycobacterium tuberculosis clinical isolates, we compared results using BACTEC 460TB method performed by collaborators and the GMD Growth Assay. Eight of 20 (40%) clinical isolates, which were not identified as drug-resistant using the conventional BACTEC 460TB method, were resistant to 1, 2, or 3 different concentrations of drugs using the GMD Growth Assay (13 cases of 140 experiments). In one case (isolate 1879), resistance to 10.0 microg/ml of STR detected using BACTEC 460TB method was not confirmed by the GMD Growth Assay. Thus, the overall agreement between these methods was 90% (14 discrepant results of 140 experiments). These data demonstrate that the GMD Growth Assay is an accurate and sensitive method for rapid susceptibility testing of Mycobacterium tuberculosis for use in clinical reference laboratory settings.

  13. [Comparison of two methods for rapid determination of C-reactive protein with the Tina-quant].

    PubMed

    Oremek, G M; Luksaite, R; Bretschneider, I

    2008-03-01

    C-reactive protein (CRP) as an acute phase protein is an important diagnostic marker for the presence and course of human processes. Out of the acute phase proteins it is one of those the concentrations increase most rapidly with its sensitivity being superior to other markers of inflammation, such as leukocytosis, erythrocytic sedimentation rate, and fever. This study compared two-point-of-care assays with the standard laboratory method Tina-quant CRP processed on a Hitachi 917: the immunofiltration assay NycoCard CRP Whole Blood and the turbidimetric immunoassay Micros CRP. Both methods are carried in the presence of a patient, by using capillary or venous blood. Seventy-eight blood samples were analyzed first in the standard laboratory routine and then by both rapid test assays. The precision of both assays was determined from the confidence interval. The results were statistically analyzed by arithmetic standard deviation mean method, variation coefficient, Spearman correlation index, Wilcoxon and Bland-Altman tests, and Passing-Bablock regression. NycoCard CRP Whole Blood showed a correlation coefficient of R = 0.9838; the precision had a coefficient of variation of CV = 1.8759% while As compared with Tina-quant CRP had R = 0.9934 and CV = 0.9160%. Both assays indicated the same results as Tina-quant CRP. Both Tina-quant CRP and NycoCard CRP Whole Blood give the best fit for the rapid determination of CRP.

  14. Application of loop-mediated isothermal amplification (LAMP) assay for the rapid diagnosis of pathogenic bacteria in clinical sputum specimens of acute exacerbation of COPD (AECOPD).

    PubMed

    Zhang, Wei; Chen, Chuanhui; Cui, Jian; Bai, Wei; Zhou, Jing

    2015-01-01

    The present study explores the application of LAMP for rapid diagnosis of pathogenic bacteria in clinical sputum specimens of AECOPD as compared with conventional sputum culturing method. 120 sputum specimens of AECOPD patients, 46 sputum specimens of healthy controls, as well as 166 serum specimens as negative controls, were evaluated by LAMP assay using primers of eight typical respiratory pathogens. No cross-reactivity was observed in these negative control species using LAMP assay. The lower detection limit of LAMP assay was approximately 10(3) copies. 25 cases (20.8%) were detected at least one positive bacteria species by conventional sputum culturing method, while 73 cases (60.8%) were tested positive in LAMP assay. Moreover, compared with sputum culture, bacterial titers results of LAMP assay were more consistent with FEV1/FVC value of AECOPD patients. These results indicated that the sensitivity of LAMP assay was significantly higher than that of sputum culturing method.

  15. Rapid Detection of Urinary Tract Infections via Bacterial Nuclease Activity.

    PubMed

    Flenker, Katie S; Burghardt, Elliot L; Dutta, Nirmal; Burns, William J; Grover, Julia M; Kenkel, Elizabeth J; Weaver, Tyler M; Mills, James; Kim, Hyeon; Huang, Lingyan; Owczarzy, Richard; Musselman, Catherine A; Behlke, Mark A; Ford, Bradley; McNamara, James O

    2017-06-07

    Rapid and accurate bacterial detection methods are needed for clinical diagnostic, water, and food testing applications. The wide diversity of bacterial nucleases provides a rich source of enzymes that could be exploited as signal amplifying biomarkers to enable rapid, selective detection of bacterial species. With the exception of the use of micrococcal nuclease activity to detect Staphylococcus aureus, rapid methods that detect bacterial pathogens via their nuclease activities have not been developed. Here, we identify endonuclease I as a robust biomarker for E. coli and develop a rapid ultrasensitive assay that detects its activity. Comparison of nuclease activities of wild-type and nuclease-knockout E. coli clones revealed that endonuclease I is the predominant DNase in E. coli lysates. Endonuclease I is detectable by immunoblot and activity assays in uropathogenic E. coli strains. A rapid assay that detects endonuclease I activity in patient urine with an oligonucleotide probe exhibited substantially higher sensitivity for urinary tract infections than that reported for rapid urinalysis methods. The 3 hr turnaround time is much shorter than that of culture-based methods, thereby providing a means for expedited administration of appropriate antimicrobial therapy. We suggest this approach could address various unmet needs for rapid detection of E. coli. Copyright © 2017 The American Society of Gene and Cell Therapy. Published by Elsevier Inc. All rights reserved.

  16. A rapid and efficient assay for extracting DNA from fungi

    USGS Publications Warehouse

    Griffin, Dale W.; Kellogg, C.A.; Peak, K.K.; Shinn, E.A.

    2002-01-01

    Aims: A method for the rapid extraction of fungal DNA from small quantities of tissue in a batch-processing format was investigated. Methods and Results: Tissue (< 3.0 mg) was scraped from freshly-grown fungal isolates. The tissue was suspended in buffer AP1 and subjected to seven rounds of freeze/thaw using a crushed dry ice/ethanol bath and a boiling water bath. After a 30 min boiling step, the tissue was quickly ground against the wall of the microfuge tube using a sterile pipette tip. The Qiagen DNeasy Plant Tissue Kit protocol was then used to purify the DNA for PCR/ sequencing applications. Conclusions: The method allowed batch DNA extraction from multiple fungal isolates using a simple yet rapid and reliable assay. Significance and Impact of the Study: Use of this assay will allow researchers to obtain DNA from fungi quickly for use in molecular assays that previously required specialized instrumentation, was time-consuming or was not conducive to batch processing.

  17. Rapid detection of mecA and spa by the loop-mediated isothermal amplification (LAMP) method.

    PubMed

    Koide, Y; Maeda, H; Yamabe, K; Naruishi, K; Yamamoto, T; Kokeguchi, S; Takashiba, S

    2010-04-01

    To develop a detection assay for staphylococcal mecA and spa by using loop-mediated isothermal amplification (LAMP) method. Staphylococcus aureus and other related species were subjected to the detection of mecA and spa by both PCR and LAMP methods. The LAMP successfully amplified the genes under isothermal conditions at 64 degrees C within 60 min, and demonstrated identical results with the conventional PCR methods. The detection limits of the LAMP for mecA and spa, by gel electrophoresis, were 10(2) and 10 cells per tube, respectively. The naked-eye inspections were possible with 10(3) and 10 cells for detection of mecA and spa, respectively. The LAMP method was then applied to sputum and dental plaque samples. The LAMP and PCR demonstrated identical results for the plaque samples, although frequency in detection of mecA and spa by the LAMP was relatively lower for the sputum samples when compared to the PCR methods. Application of the LAMP enabled a rapid detection assay for mecA and spa. The assay may be applicable to clinical plaque samples. The LAMP offers an alternative detection assay for mecA and spa with a great advantage of the rapidity.

  18. Multicenter Evaluation of the Cepheid Xpert Methicillin-Resistant Staphylococcus aureus (MRSA) Test as a Rapid Screening Method for Detection of MRSA in Nares▿

    PubMed Central

    Wolk, D. M.; Picton, E.; Johnson, D.; Davis, T.; Pancholi, P.; Ginocchio, C. C.; Finegold, S.; Welch, D. F.; de Boer, M.; Fuller, D.; Solomon, M. C.; Rogers, B.; Mehta, M. S.; Peterson, L. R.

    2009-01-01

    The first U.S. multicenter clinical trial to assess the performance of the Cepheid Xpert MRSA assay (Xpert MRSA) was conducted. The assay is a qualitative test designed for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) directly from nares swabs. This novel test combines integrated nucleic acid extraction and automated real-time PCR for the detection of a MRSA-specific signature sequence. A total of 1,077 nares specimens were collected from seven geographically distinct health care sites across the United States with prevalence rates ranging from 5.2% to 44%. Nares specimens were tested by (i) the Xpert MRSA assay, (ii) direct culture on CHROMagar MRSA medium (direct CM culture), and (iii) broth-enriched culture (Trypticase soy broth with 6.5% sodium chloride) followed by plating onto CHROMagar MRSA medium (broth-enriched CM culture). When direct CM culture was designated the reference method, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the Xpert MRSA assay were 94.3%, 93.2%, 73.0%, and 98.8%, respectively. When broth-enriched CM culture was used as the reference method, the clinical sensitivity, specificity, PPV, and NPV of the Xpert MRSA assay were 86.3%, 94.9%, 80.5%, and 96.6%, respectively. The BD GeneOhm MRSA (BDGO) assay was performed as a comparative molecular method. No statistical performance differences were observed between the Xpert MRSA and BDGO assays when they were compared to culture methods. From this large-scale, multicenter clinical comparison, we conclude that the Xpert MRSA assay is a simple, rapid, and accurate method for performing active surveillance for MRSA in a variety of health care populations. PMID:19129414

  19. A complementation assay for in vivo protein structure/function analysis in Physcomitrella patens (Funariaceae)

    DOE PAGES

    Scavuzzo-Duggan, Tess R.; Chaves, Arielle M.; Roberts, Alison W.

    2015-07-14

    Here, a method for rapid in vivo functional analysis of engineered proteins was developed using Physcomitrella patens. A complementation assay was designed for testing structure/function relationships in cellulose synthase (CESA) proteins. The components of the assay include (1) construction of test vectors that drive expression of epitope-tagged PpCESA5 carrying engineered mutations, (2) transformation of a ppcesa5 knockout line that fails to produce gametophores with test and control vectors, (3) scoring the stable transformants for gametophore production, (4) statistical analysis comparing complementation rates for test vectors to positive and negative control vectors, and (5) analysis of transgenic protein expression by Westernmore » blotting. The assay distinguished mutations that generate fully functional, nonfunctional, and partially functional proteins. In conclusion, compared with existing methods for in vivo testing of protein function, this complementation assay provides a rapid method for investigating protein structure/function relationships in plants.« less

  20. A RAPID AND SIMPLE PHOSPHOLIPASE A ASSAY,

    DTIC Science & Technology

    A simple and rapid method for the assay of phospholipase A was developed. As a substrate fresh egg yolk is used which is hydrolyzed by snake venom...phospholipase A at a 10-20 x faster rate than pure lecithin . The released fatty acids, after extraction with appropriate solvents are titrated

  1. Real-time PCR-based method for the rapid detection of extended RAS mutations using bridged nucleic acids in colorectal cancer.

    PubMed

    Iida, Takao; Mizuno, Yukie; Kaizaki, Yasuharu

    2017-10-27

    Mutations in RAS and BRAF are predictors of the efficacy of anti-epidermal growth factor receptor (EGFR) therapy in patients with metastatic colorectal cancer (mCRC). Therefore, simple, rapid, cost-effective methods to detect these mutations in the clinical setting are greatly needed. In the present study, we evaluated BNA Real-time PCR Mutation Detection Kit Extended RAS (BNA Real-time PCR), a real-time PCR method that uses bridged nucleic acid clamping technology to rapidly detect mutations in RAS exons 2-4 and BRAF exon 15. Genomic DNA was extracted from 54 formalin-fixed paraffin-embedded (FFPE) tissue samples obtained from mCRC patients. Among the 54 FFPE samples, BNA Real-time PCR detected 21 RAS mutations (38.9%) and 5 BRAF mutations (9.3%), and the reference assay (KRAS Mutation Detection Kit and MEBGEN™ RASKET KIT) detected 22 RAS mutations (40.7%). The concordance rate of detected RAS mutations between the BNA Real-time PCR assay and the reference assays was 98.2% (53/54). The BNA Real-time PCR assay proved to be a more simple, rapid, and cost-effective method for detecting KRAS and RAS mutations compared with existing assays. These findings suggest that BNA Real-time PCR is a valuable tool for predicting the efficacy of early anti-EGFR therapy in mCRC patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A Rapid and Simple Real-Time PCR Assay for Detecting Foodborne Pathogenic Bacteria in Human Feces.

    PubMed

    Hanabara, Yutaro; Ueda, Yutaka

    2016-11-22

    A rapid, simple method for detecting foodborne pathogenic bacteria in human feces is greatly needed. Here, we examined the efficacy of a method that employs a combination of a commercial PCR master mix, which is insensitive to PCR inhibitors, and a DNA extraction method which used sodium dodecyl benzene sulfonate (SDBS), and Tween 20 to counteract the inhibitory effects of SDBS on the PCR assay. This method could detect the target genes (stx1 and stx2 of enterohemorrhagic Escherichia coli, invA of Salmonella Enteritidis, tdh of Vibrio parahaemolyticus, gyrA of Campylobacter jejuni, ceuE of Campylobacter coli, SEA of Staphylococcus aureus, ces of Bacillus cereus, and cpe of Clostridium perfringens) in a fecal suspension containing 1.0 × 10 1 to 1.0 × 10 3 CFU/ml. Furthermore, the assay was neither inhibited nor influenced by individual differences among the fecal samples of 10 subjects or fecal concentration (40-160 mg/ml in the fecal suspension). When we attempted to detect the genes of pathogenic bacteria in 4 actual clinical cases, we found that this method was more sensitive than standard culture method. These results showed that this assay is a rapid, simple detection method for foodborne pathogenic bacteria in human feces.

  3. Rapid and sensitive detection of mink circovirus by recombinase polymerase amplification.

    PubMed

    Ge, Junwei; Shi, Yunjia; Cui, Xingyang; Gu, Shanshan; Zhao, Lili; Chen, Hongyan

    2018-06-01

    To date, the pathogenic role of mink circovirus (MiCV) remains unclear, and its prevalence and economic importance are unknown. Therefore, a rapid and sensitive molecular diagnosis is necessary for disease management and epidemiological surveillance. However, only PCR methods can identify MiCV infection at present. In this study, we developed a nested PCR and established a novel recombinase polymerase amplification (RPA) assay for MiCV detection. Sensitivity analysis showed that the detection limit of nested PCR and RPA assay was 10 1 copies/reaction, and these methods were more sensitive than conventional PCR, which has a detection limit of 10 5 copies/reaction. The RPA assay had no cross-reactivity with other related viral pathogens, and amplification was completed in less than 20 min with a simple device. Further assessment of clinical samples showed that the two assays were accurate in identifying positive and negative conventional PCR samples. The detection rate of MiCV by the RPA assay in clinical samples was 38.09%, which was 97% consistent with that by the nested PCR. The developed nested PCR is a highly sensitive tool for practical use, and the RPA assay is a simple, sensitive, and potential alternative method for rapid and accurate MiCV diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Colorimetric micro-assay for accelerated screening of mould inhibitors

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2013-01-01

    Since current standard laboratory methods are time-consuming macro-assays that rely on subjective visual ratings of mould growth, rapid and quantitative laboratory methods are needed to screen potential mould inhibitors for use in and on cellulose-based products. A colorimetric micro-assay has been developed that uses XTT tetrazolium salt to enzymatically assess...

  5. Establishment and Application of a Loop-Mediated Isothermal Amplification Method for Simple, Specific, Sensitive and Rapid Detection of Toxoplasma gondii

    PubMed Central

    CAO, Lili; CHENG, Ronghua; YAO, Lin; YUAN, Shuxian; YAO, Xinhua

    2013-01-01

    ABSTRACT The Loop-mediated isothermal amplification (LAMP) method amplifies DNA with high simply, specificity, sensitivity and rapidity. In this study, A LAMP assay with 6 primers targeting a highly conserved region of the GRA1 gene was developed to diagnose Toxoplasma gondii. The reaction time of the LAMP assay was shortened to 30 min after optimizing the reaction system. The LAMP assay was found to be highly specific and stable. The detection limit of the LAMP assay was 10 copies, the same as that of the conventional PCR. We used the LAMP assay to develop a real-time fluorogenic protocol to quantitate T. gondii DNA and generated a log-linear regression plot by plotting the time-to-threshold values against genomic equivalent copies. Furthermore, the LAMP assay was applied to detect T. gondii DNA in 423 blood samples and 380 lymph node samples from 10 pig farms, and positive results were obtained for 7.8% and 8.2% of samples, respectively. The results showed that the LAMP method is slightly more sensitive than conventional PCR (6.1% and 7.6%). Positive samples obtained from 6 pig farms. The LAMP assay established in this study resulted in simple, specific, sensitive and rapid detection of T. gondii DNA and is expected to play an important role in clinical detection of T. gondii. PMID:23965849

  6. Rapid molecular assays for the detection of yellow fever virus in low-resource settings.

    PubMed

    Escadafal, Camille; Faye, Oumar; Sall, Amadou Alpha; Faye, Ousmane; Weidmann, Manfred; Strohmeier, Oliver; von Stetten, Felix; Drexler, Josef; Eberhard, Michael; Niedrig, Matthias; Patel, Pranav

    2014-03-01

    Yellow fever (YF) is an acute viral hemorrhagic disease transmitted by Aedes mosquitoes. The causative agent, the yellow fever virus (YFV), is found in tropical and subtropical areas of South America and Africa. Although a vaccine is available since the 1930s, YF still causes thousands of deaths and several outbreaks have recently occurred in Africa. Therefore, rapid and reliable diagnostic methods easy to perform in low-resources settings could have a major impact on early detection of outbreaks and implementation of appropriate response strategies such as vaccination and/or vector control. The aim of this study was to develop a YFV nucleic acid detection method applicable in outbreak investigations and surveillance studies in low-resource and field settings. The method should be simple, robust, rapid and reliable. Therefore, we adopted an isothermal approach and developed a recombinase polymerase amplification (RPA) assay which can be performed with a small portable instrument and easy-to-use lyophilized reagents. The assay was developed in three different formats (real-time with or without microfluidic semi-automated system and lateral-flow assay) to evaluate their application for different purposes. Analytical specificity and sensitivity were evaluated with a wide panel of viruses and serial dilutions of YFV RNA. Mosquito pools and spiked human plasma samples were also tested for assay validation. Finally, real-time RPA in portable format was tested under field conditions in Senegal. The assay was able to detect 20 different YFV strains and demonstrated no cross-reactions with closely related viruses. The RPA assay proved to be a robust, portable method with a low detection limit (<21 genome equivalent copies per reaction) and rapid processing time (<20 min). Results from real-time RPA field testing were comparable to results obtained in the laboratory, thus confirming our method is suitable for YFV detection in low-resource settings.

  7. Rapid Molecular Assays for the Detection of Yellow Fever Virus in Low-Resource Settings

    PubMed Central

    Escadafal, Camille; Faye, Oumar; Sall, Amadou Alpha; Faye, Ousmane; Weidmann, Manfred; Strohmeier, Oliver; von Stetten, Felix; Drexler, Josef; Eberhard, Michael; Niedrig, Matthias; Patel, Pranav

    2014-01-01

    Background Yellow fever (YF) is an acute viral hemorrhagic disease transmitted by Aedes mosquitoes. The causative agent, the yellow fever virus (YFV), is found in tropical and subtropical areas of South America and Africa. Although a vaccine is available since the 1930s, YF still causes thousands of deaths and several outbreaks have recently occurred in Africa. Therefore, rapid and reliable diagnostic methods easy to perform in low-resources settings could have a major impact on early detection of outbreaks and implementation of appropriate response strategies such as vaccination and/or vector control. Methodology The aim of this study was to develop a YFV nucleic acid detection method applicable in outbreak investigations and surveillance studies in low-resource and field settings. The method should be simple, robust, rapid and reliable. Therefore, we adopted an isothermal approach and developed a recombinase polymerase amplification (RPA) assay which can be performed with a small portable instrument and easy-to-use lyophilized reagents. The assay was developed in three different formats (real-time with or without microfluidic semi-automated system and lateral-flow assay) to evaluate their application for different purposes. Analytical specificity and sensitivity were evaluated with a wide panel of viruses and serial dilutions of YFV RNA. Mosquito pools and spiked human plasma samples were also tested for assay validation. Finally, real-time RPA in portable format was tested under field conditions in Senegal. Conclusion/Significance The assay was able to detect 20 different YFV strains and demonstrated no cross-reactions with closely related viruses. The RPA assay proved to be a robust, portable method with a low detection limit (<21 genome equivalent copies per reaction) and rapid processing time (<20 min). Results from real-time RPA field testing were comparable to results obtained in the laboratory, thus confirming our method is suitable for YFV detection in low-resource settings. PMID:24603874

  8. Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25.

    PubMed

    Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan

    2013-11-01

    The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg(-1) GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25.

  9. Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25

    PubMed Central

    Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan

    2013-01-01

    The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg−1 GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25. PMID:24804053

  10. A rapid colorimetric assay for mold spore germination using XTT tetrazolium salt

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2011-01-01

    Current laboratory test methods to measure efficacy of new mold inhibitors are time consuming, some require specialized test equipment and ratings are subjective. Rapid, simple quantitative assays to measure the efficacy of mold inhibitors are needed. A quantitative, colorimetric microassay was developed using XTT tetrazolium salt to metabolically assess mold spore...

  11. A rapid method for the determination of microbial susceptibility using the firefly luciferase assay for adenosine triphosphate (ATP)

    NASA Technical Reports Server (NTRS)

    Vellend, H.; Tuttle, S. A.; Barza, M.; Weinstein, L.; Picciolo, G. L.; Chappelle, E. W.

    1975-01-01

    Luciferase assay for adenosine triphosphate (ATP) was optimized for pure bacteria in broth in order to evaluate if changes in bacterial ATP content could be used as a rapid measure of antibiotic effect on microorganisms. Broth cultures of log phase bacteria were incubated at 310 K (37 C) for 2.5 hours at antimicrobial concentrations which resulted in the best discrimination between sensitive and resistant strains. Eighty-seven strains of 11 bacterial species were studied for their susceptibility to 12 commonly used antimicrobial agents: ampicillin, Penicillin G, nafcillin, carbenicillin, cephalothin, tetracycline, erythromycin, clindamycin, gentamicin, nitrofurantoin, colistin, and chloramplenicol. The major advantage of the ATP system over existing methods of rapid microbial susceptibility testing is that the assay can be made specific for bacterial ATP.

  12. A simple microplate-based method for the determination of α-amylase activity using the glucose assay kit (GOD method).

    PubMed

    Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini

    2016-11-15

    For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. A multiplex PCR assay for the rapid and sensitive detection of methicillin-resistant Staphylococcus aureus and simultaneous discrimination of Staphylococcus aureus from coagulase-negative staphylococci.

    PubMed

    Xu, Benjin; Liu, Ling; Liu, Li; Li, Xinping; Li, Xiaofang; Wang, Xin

    2012-11-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a global health concern, which had been detected in food and food production animals. Conventional testing for detection of MRSA takes 3 to 5 d to yield complete information of the organism and its antibiotic sensitivity pattern. So, a rapid method is needed to diagnose and treat the MRSA infections. The present study focused on the development of a multiplex PCR assay for the rapid and sensitive detection of MRSA. The assay simultaneously detected 4 genes, namely, 16S rRNA of the Staphylococcus genus, femA of S. aureus, mecA that encodes methicillin resistance, and one internal control. It was rapid and yielded results within 4 h. The analytical sensitivity and specificity of the multiplex PCR assay was evaluated by comparing it with the conventional method. The analytical sensitivity of the multiplex PCR assay at the DNA level was 10 ng DNA. The analytical specificity was evaluated with 10 reference staphylococci strains and was 100%. The diagnostic evaluation of MRSA was carried out using 360 foodborne staphylococci isolates, and showed 99.1% of specificity, 96.4% of sensitivity, 97.5% of positive predictive value, and 97.3% of negative predictive value compared to the conventional method. The inclusion of an internal control in the multiplex PCR assay is important to exclude false-negative cases. This test can be used as an effective diagnostic and surveillance tool to investigate the spread and emergence of MRSA. © 2012 Institute of Food Technologists®

  14. Rapid specific and visible detection of porcine circovirus type 3 using loop-mediated isothermal amplification (LAMP).

    PubMed

    Zheng, S; Wu, X; Shi, J; Peng, Z; Gao, M; Xin, C; Liu, Y; Wang, S; Xu, S; Han, H; Yu, J; Sun, W; Cong, X; Li, J; Wang, J

    2018-06-01

    In this study, a rapid and specific assay for the detection of porcine circovirus type 3 (PCV3) was established using loop-mediated isothermal amplification (LAMP). Four primers were specifically designed to amplify PCV3. The LAMP assay was effectively optimized to amplify PCV3 by water bath at 60°C for 60 min. The detection limit was approximately 1 × 10 1 copy in this LAMP assay. Compared to porcine circovirus type 2 (PCV2), both gE and gD genes of pseudorabies virus (PRV) and porcine parvovirus (PPV), the LAMP assay showed a high specific detection of PCV3. A visible detection method was developed using SYBR Green I to recognize the results rapidly. Based on the detection of 20 clinical tissue samples, the LAMP assay was more practical and convenient than classical PCR due to its simplicity, high sensitivity, rapidity, specificity, visibility and cost efficiency. © 2018 Blackwell Verlag GmbH.

  15. [Development of sample pretreatment techniques-rapid detection coupling methods for food security analysis].

    PubMed

    Huang, Yichun; Ding, Weiwei; Zhang, Zhuomin; Li, Gongke

    2013-07-01

    This paper summarizes the recent developments of the rapid detection methods for food security, such as sensors, optical techniques, portable spectral analysis, enzyme-linked immunosorbent assay, portable gas chromatograph, etc. Additionally, the applications of these rapid detection methods coupled with sample pretreatment techniques in real food security analysis are reviewed. The coupling technique has the potential to provide references to establish the selective, precise and quantitative rapid detection methods in food security analysis.

  16. [Prediction of the side-cut product yield of atmospheric/vacuum distillation unit by NIR crude oil rapid assay].

    PubMed

    Wang, Yan-Bin; Hu, Yu-Zhong; Li, Wen-Le; Zhang, Wei-Song; Zhou, Feng; Luo, Zhi

    2014-10-01

    In the present paper, based on the fast evaluation technique of near infrared, a method to predict the yield of atmos- pheric and vacuum line was developed, combined with H/CAMS software. Firstly, the near-infrared (NIR) spectroscopy method for rapidly determining the true boiling point of crude oil was developed. With commercially available crude oil spectroscopy da- tabase and experiments test from Guangxi Petrochemical Company, calibration model was established and a topological method was used as the calibration. The model can be employed to predict the true boiling point of crude oil. Secondly, the true boiling point based on NIR rapid assay was converted to the side-cut product yield of atmospheric/vacuum distillation unit by H/CAMS software. The predicted yield and the actual yield of distillation product for naphtha, diesel, wax and residual oil were compared in a 7-month period. The result showed that the NIR rapid crude assay can predict the side-cut product yield accurately. The near infrared analytic method for predicting yield has the advantages of fast analysis, reliable results, and being easy to online operate, and it can provide elementary data for refinery planning optimization and crude oil blending.

  17. One-Step Immunochromatography Assay Kit for Detecting Antibodies to Canine Parvovirus

    PubMed Central

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-01-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the “gold standard.” These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited. PMID:16603622

  18. One-step immunochromatography assay kit for detecting antibodies to canine parvovirus.

    PubMed

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-04-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the "gold standard." These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited.

  19. Comparative analysis and validation of the malachite green assay for the high throughput biochemical characterization of terpene synthases

    PubMed Central

    Vardakou, Maria; Salmon, Melissa; Faraldos, Juan A.; O’Maille, Paul E.

    2014-01-01

    Terpenes are the largest group of natural products with important and diverse biological roles, while of tremendous economic value as fragrances, flavours and pharmaceutical agents. Class-I terpene synthases (TPSs), the dominant type of TPS enzymes, catalyze the conversion of prenyl diphosphates to often structurally diverse bioactive terpene hydrocarbons, and inorganic pyrophosphate (PPi). To measure their kinetic properties, current bio-analytical methods typically rely on the direct detection of hydrocarbon products by radioactivity measurements or gas chromatography–mass spectrometry (GC–MS). In this study we employed an established, rapid colorimetric assay, the pyrophosphate/malachite green assay (MG), as an alternative means for the biochemical characterization of class I TPSs activity.•We describe the adaptation of the MG assay for turnover and catalytic efficiency measurements of TPSs.•We validate the method by direct comparison with established assays. The agreement of kcat/KM among methods makes this adaptation optimal for rapid evaluation of TPSs.•We demonstrate the application of the MG assay for the high-throughput screening of TPS gene libraries. PMID:26150952

  20. Comparative analysis and validation of the malachite green assay for the high throughput biochemical characterization of terpene synthases.

    PubMed

    Vardakou, Maria; Salmon, Melissa; Faraldos, Juan A; O'Maille, Paul E

    2014-01-01

    Terpenes are the largest group of natural products with important and diverse biological roles, while of tremendous economic value as fragrances, flavours and pharmaceutical agents. Class-I terpene synthases (TPSs), the dominant type of TPS enzymes, catalyze the conversion of prenyl diphosphates to often structurally diverse bioactive terpene hydrocarbons, and inorganic pyrophosphate (PPi). To measure their kinetic properties, current bio-analytical methods typically rely on the direct detection of hydrocarbon products by radioactivity measurements or gas chromatography-mass spectrometry (GC-MS). In this study we employed an established, rapid colorimetric assay, the pyrophosphate/malachite green assay (MG), as an alternative means for the biochemical characterization of class I TPSs activity.•We describe the adaptation of the MG assay for turnover and catalytic efficiency measurements of TPSs.•We validate the method by direct comparison with established assays. The agreement of k cat/K M among methods makes this adaptation optimal for rapid evaluation of TPSs.•We demonstrate the application of the MG assay for the high-throughput screening of TPS gene libraries.

  1. Rapid visual detection of Mycobacterium avium subsp. paratuberculosis by recombinase polymerase amplification combined with a lateral flow dipstick

    PubMed Central

    Zhao, Guimin; Wang, Hongmei; Hou, Peili; He, Chengqiang

    2018-01-01

    Paratuberculosis (Johne's disease) is a chronic debilitating disease of domestic and wild ruminants. However, widespread point-of-care testing is infrequent due to the lack of a robust method. The isothermal recombinase polymerase amplification (RPA) technique has applied for rapid diagnosis. Herein, RPA combined with a lateral flow dipstick (LFD) assay was developed to estimate DNA from Mycobacterium avium subsp. paratuberculosis. First, analytical specificity and sensitivity of the RPA-nfo primer and probe sets were assessed. The assay successfully detected M. paratuberculosis DNA in 30 min at 39℃ with a detection limit of up to eight copies per reaction, which was equivalent to that of the real-time quantitative polymerase chain reaction (qPCR) assay. The assay was specific, as it did not amplify genomes from five other Mycobacterium spp. or five pathogenic enteric bacteria. Six hundred-twelve clinical samples (320 fecal and 292 serum) were assessed by RPA-LFD, qPCR, and enzyme-linked immunosorbent assay, respectively. The RPA-LFD assay yielded 100% sensitivity, 97.63% specificity, and 98.44% concordance rate with the qPCR results. This is the first report utilizing an RPA-LFD assay to visualize and rapidly detect M. paratuberculosis. Our results show this assay should be a useful method for the diagnosis of paratuberculosis in resource-constrained settings. PMID:29284204

  2. Rapid visual detection of Mycobacterium avium subsp. paratuberculosis by recombinase polymerase amplification combined with a lateral flow dipstick.

    PubMed

    Zhao, Guimin; Wang, Hongmei; Hou, Peili; He, Chengqiang; He, Hongbin

    2018-03-31

    Paratuberculosis (Johne's disease) is a chronic debilitating disease of domestic and wild ruminants. However, widespread point-of-care testing is infrequent due to the lack of a robust method. The isothermal recombinase polymerase amplification (RPA) technique has applied for rapid diagnosis. Herein, RPA combined with a lateral flow dipstick (LFD) assay was developed to estimate DNA from Mycobacterium avium subsp. paratuberculosis . First, analytical specificity and sensitivity of the RPA-nfo primer and probe sets were assessed. The assay successfully detected M. paratuberculosis DNA in 30 min at 39°C with a detection limit of up to eight copies per reaction, which was equivalent to that of the real-time quantitative polymerase chain reaction (qPCR) assay. The assay was specific, as it did not amplify genomes from five other Mycobacterium spp. or five pathogenic enteric bacteria. Six hundred-twelve clinical samples (320 fecal and 292 serum) were assessed by RPA-LFD, qPCR, and enzyme-linked immunosorbent assay, respectively. The RPA-LFD assay yielded 100% sensitivity, 97.63% specificity, and 98.44% concordance rate with the qPCR results. This is the first report utilizing an RPA-LFD assay to visualize and rapidly detect M. paratuberculosis . Our results show this assay should be a useful method for the diagnosis of paratuberculosis in resource-constrained settings.

  3. The use of newly developed real-time PCR for the rapid identification of bacteria in culture-negative osteomyelitis.

    PubMed

    Kobayashi, Naomi; Bauer, Thomas W; Sakai, Hiroshige; Togawa, Daisuke; Lieberman, Isador H; Fujishiro, Takaaki; Procop, Gary W

    2006-12-01

    We report a case of a culture-negative osteomyelitis in which our newly developed real-time polymerase chain reaction (PCR) could differentiate Staphylococcus aureus from Staphylococcus epidermidis. This is the first report that described the application of this novel assay to an orthopedics clinical sample. This assay may be useful for other clinical culture-negative cases in a combination with a broad-spectrum assay as a rapid microorganism identification method.

  4. Development of a pan-rickettsial molecular diagnostic test based on recombinase polymerase amplification assay.

    PubMed

    Kissenkötter, Jonas; Hansen, Sören; Böhlken-Fascher, Susanne; Ademowo, Olusegun George; Oyinloye, Oladapo Elijah; Bakarey, Adeleye Solomon; Dobler, Gerhard; Tappe, Dennis; Patel, Pranav; Czerny, Claus-Peter; Abd El Wahed, Ahmed

    2018-03-01

    Rickettsioses are zoonotic vector-transmitted bacterial infections leading to flu-like symptoms and can progress to severe illness in humans. The gold standard for diagnosis of rickettsial infections is the indirect immunofluorescence assay, a serological method which is not suitable for pathogen identification during the acute phase of the disease. Therefore, several real-time PCR assays were developed. These assays are very sensitive, but require high-equipped laboratories and well-trained personnel. Hence, in this study, a rapid point-of-need detection method was developed to detect all Rickettsia species. The 23S and 16S rRNA genes were targeted to develop a recombinase polymerase amplification (RPA) assay. Both 23S and 16S_RPA assays required between seven to ten minutes to amplify and detect one or ten DNA molecules/reaction, respectively. The 16S_RPA assay detected all tested species, whereas the 23S_RPA assay identified only species of the spotted fever and transitional rickettsial groups. All results were compared with real-time PCR assays directed against the same rickettsial genes. The RPA assays are easy to handle and produced quicker results in comparison to real-time PCRs. Both RPA assays were implemented in a mobile suitcase laboratory to ease the use in rural areas. This method can help to provide rapid management of rickettsial infections. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. A Rapid Method for Quantifying Viable Mycobacterium avium subsp. paratuberculosis in Cellular Infection Assays

    PubMed Central

    Pooley, Hannah B.; de Silva, Kumudika; Purdie, Auriol C.; Begg, Douglas J.; Whittington, Richard J.

    2016-01-01

    ABSTRACT Determining the viability of bacteria is a key outcome of in vitro cellular infection assays. Currently, this is done by culture, which is problematic for fastidious slow-growing bacteria such as Mycobacterium avium subsp. paratuberculosis, where it can take up to 4 months to confirm growth. This study aimed to identify an assay that can rapidly quantify the number of viable M. avium subsp. paratuberculosis cells in a cellular sample. Three commercially available bacterial viability assays along with a modified liquid culture method coupled with high-throughput quantitative PCR growth detection were assessed. Criteria for assessment included the ability of each assay to differentiate live and dead M. avium subsp. paratuberculosis organisms and their accuracy at low bacterial concentrations. Using the culture-based method, M. avium subsp. paratuberculosis growth was reliably detected and quantified within 2 weeks. There was a strong linear association between the 2-week growth rate and the initial inoculum concentration. The number of viable M. avium subsp. paratuberculosis cells in an unknown sample was quantified based on the growth rate, by using growth standards. In contrast, none of the commercially available viability assays were suitable for use with samples from in vitro cellular infection assays. IMPORTANCE Rapid quantification of the viability of Mycobacterium avium subsp. paratuberculosis in samples from in vitro cellular infection assays is important, as it allows these assays to be carried out on a large scale. In vitro cellular infection assays can function as a preliminary screening tool, for vaccine development or antimicrobial screening, and also to extend findings derived from experimental animal trials. Currently, by using culture, it takes up to 4 months to obtain quantifiable results regarding M. avium subsp. paratuberculosis viability after an in vitro infection assay; however, with the quantitative PCR and liquid culture method developed, reliable results can be obtained at 2 weeks. This method will be important for vaccine and antimicrobial screening work, as it will allow a greater number of candidates to be screened in the same amount of time, which will increase the likelihood that a favorable candidate will be found to be subjected to further testing. PMID:27371585

  6. A rapid, efficient, and economic device and method for the isolation and purification of mouse islet cells

    PubMed Central

    Zongyi, Yin; Funian, Zou; Hao, Li; Ying, Cheng; Jialin, Zhang

    2017-01-01

    Rapid, efficient, and economic method for the isolation and purification of islets has been pursued by numerous islet-related researchers. In this study, we compared the advantages and disadvantages of our developed patented method with those of commonly used conventional methods (Ficoll-400, 1077, and handpicking methods). Cell viability was assayed using Trypan blue, cell purity and yield were assayed using diphenylthiocarbazone, and islet function was assayed using acridine orange/ethidium bromide staining and enzyme-linked immunosorbent assay-glucose stimulation testing 4 days after cultivation. The results showed that our islet isolation and purification method required 12 ± 3 min, which was significantly shorter than the time required in Ficoll-400, 1077, and HPU groups (34 ± 3, 41 ± 4, and 30 ± 4 min, respectively; P < 0.05). There was no significant difference in islet viability among the four groups. The islet purity, function, yield, and cost of our method were superior to those of the Ficoll-400 and 1077 methods, but inferior to the handpicking method. However, the handpicking method may cause wrist injury and visual impairment in researchers during large-scale islet isolation (>1000 islets). In summary, the MCT method is a rapid, efficient, and economic method for isolating and purifying murine islet cell clumps. This method overcomes some of the shortcomings of conventional methods, showing a relatively higher quality and yield of islets within a shorter duration at a lower cost. Therefore, the current method provides researchers with an alternative option for islet isolation and should be widely generalized. PMID:28207765

  7. A rapid, efficient, and economic device and method for the isolation and purification of mouse islet cells.

    PubMed

    Zongyi, Yin; Funian, Zou; Hao, Li; Ying, Cheng; Jialin, Zhang; Baifeng, Li

    2017-01-01

    Rapid, efficient, and economic method for the isolation and purification of islets has been pursued by numerous islet-related researchers. In this study, we compared the advantages and disadvantages of our developed patented method with those of commonly used conventional methods (Ficoll-400, 1077, and handpicking methods). Cell viability was assayed using Trypan blue, cell purity and yield were assayed using diphenylthiocarbazone, and islet function was assayed using acridine orange/ethidium bromide staining and enzyme-linked immunosorbent assay-glucose stimulation testing 4 days after cultivation. The results showed that our islet isolation and purification method required 12 ± 3 min, which was significantly shorter than the time required in Ficoll-400, 1077, and HPU groups (34 ± 3, 41 ± 4, and 30 ± 4 min, respectively; P < 0.05). There was no significant difference in islet viability among the four groups. The islet purity, function, yield, and cost of our method were superior to those of the Ficoll-400 and 1077 methods, but inferior to the handpicking method. However, the handpicking method may cause wrist injury and visual impairment in researchers during large-scale islet isolation (>1000 islets). In summary, the MCT method is a rapid, efficient, and economic method for isolating and purifying murine islet cell clumps. This method overcomes some of the shortcomings of conventional methods, showing a relatively higher quality and yield of islets within a shorter duration at a lower cost. Therefore, the current method provides researchers with an alternative option for islet isolation and should be widely generalized.

  8. A rapid and efficient branched DNA hybridization assay to titer lentiviral vectors.

    PubMed

    Nair, Ayyappan; Xie, Jinger; Joshi, Sarasijam; Harden, Paul; Davies, Joan; Hermiston, Terry

    2008-11-01

    A robust assay to titer lentiviral vectors is imperative to qualifying their use in drug discovery, target validation and clinical applications. In this study, a novel branched DNA based hybridization assay was developed to titer lentiviral vectors by quantifying viral RNA genome copy numbers from viral lysates without having to purify viral RNA, and this approach was compared with other non-functional (p24 protein ELISA and viral RT-qPCR) and a functional method (reporter gene expression) used commonly. The RT-qPCR method requires purification of viral RNA and the accuracy of titration therefore depends on the efficiency of purification; this requirement is ameliorated in the hybridization assay as RNA is measured directly in viral lysates. The present study indicates that the hybridization based titration assay performed on viral lysates was more accurate and has additional advantages of being rapid, robust and not dependent on transduction efficiency in different cell types.

  9. A rapid enzymatic assay for high-throughput screening of adenosine-producing strains

    PubMed Central

    Dong, Huina; Zu, Xin; Zheng, Ping; Zhang, Dawei

    2015-01-01

    Adenosine is a major local regulator of tissue function and industrially useful as precursor for the production of medicinal nucleoside substances. High-throughput screening of adenosine overproducers is important for industrial microorganism breeding. An enzymatic assay of adenosine was developed by combined adenosine deaminase (ADA) with indophenol method. The ADA catalyzes the cleavage of adenosine to inosine and NH3, the latter can be accurately determined by indophenol method. The assay system was optimized to deliver a good performance and could tolerate the addition of inorganic salts and many nutrition components to the assay mixtures. Adenosine could be accurately determined by this assay using 96-well microplates. Spike and recovery tests showed that this assay can accurately and reproducibly determine increases in adenosine in fermentation broth without any pretreatment to remove proteins and potentially interfering low-molecular-weight molecules. This assay was also applied to high-throughput screening for high adenosine-producing strains. The high selectivity and accuracy of the ADA assay provides rapid and high-throughput analysis of adenosine in large numbers of samples. PMID:25580842

  10. Validation of a rapid bacteria endospore enumeration system for use with spacecraft assembly

    NASA Astrophysics Data System (ADS)

    Chen, F.; Kuhlman, G.; Kirschner, L.; Kazarians, G.; Matsuyama, A.; Pickett, M.; Venkateswaran, K.; Kastner, J.; Kern, R.

    NASA planetary protection policy sets forth strict limits on the number of bacterial endospores that can be present on a spacecraft at launch Currently the only approved method for counting the spores is a culture based assay that requires three days to produce results a timeframe that can be at odds with the rapid pace and rigorous deadlines of spacecraft assembly A possible alternative to the traditional culture based approach is the Millipore Rapid Microbiology Detection System RMDS which has previously been used for process and contamination control in the pharmaceutical and food industries The RMDS is rapid and simple shows high sensitivity 1 colony forming unit CFU sample and correlates well with traditional culture-based methods It combines membrane filtration adenosine triphosphate ATP bioluminescence chemistry and image analysis based on photon detection with a Charge Coupled Device CCD camera In this study we have optimized the assay condition and evaluated the use of the RMDS as a rapid spore detection tool for NASA applications Seven species of Bacillus nine strains that have been repeatedly isolated from clean room environments were assayed In order to select for spores the samples were subjected to a heat shock step before proceeding with the RMDS incubation protocol All strains were detected by the RMDS in sim 5 hours and these assay times were repeatedly demonstrated along with low image background noise The RMDS-based spore detection method is undergoing the final stages of validation and is

  11. Rapid detection and classification of Salmonella enterica shedding in feedlot cattle utilizing Roka Bioscience Atlas Salmonella detection assay for the analysis of rectoanal mucosal swabs

    USDA-ARS?s Scientific Manuscript database

    With an increasing focus on preharvest food safety, rapid methods are required for the detection and quantification of foodborne pathogens such as Salmonella enterica in beef cattle. We validated the Atlas Salmonella Detection Assay (SEN), a nucleic acid amplification technology that targets Salmone...

  12. A novel strategy for rapid detection of NT-proBNP

    NASA Astrophysics Data System (ADS)

    Cui, Qiyao; Sun, Honghao; Zhu, Hui

    2017-09-01

    In order to establish a simple, rapid, sensitive, and specific quantitative assay to detect the biomarkers of heart failure, in this study, biotin-streptavidin technology was employed with fluorescence immunochromatographic assay to detect the concentration of the biomarkers in serum, and this method was applied to detect NT-proBNP, which is valuable for diagnostic evaluation of heart failure.

  13. Development of loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Penicillium nordicum in dry-cured meat products.

    PubMed

    Ferrara, M; Perrone, G; Gallo, A; Epifani, F; Visconti, A; Susca, A

    2015-06-02

    The need of powerful diagnostic tools for rapid, simple, and cost-effective detection of food-borne fungi has become very important in the area of food safety. Currently, several isothermal nucleic acid amplification methods have been developed as an alternative to PCR-based analyses. Loop-mediated isothermal amplification (LAMP) is one of these innovative methods; it requires neither gel electrophoresis to separate and visualize the products nor expensive laboratory equipment and it has been applied already for detection of pathogenic organisms. In the current study, we developed a LAMP assay for the specific detection of Penicillium nordicum, the major causative agent of ochratoxin A contamination in protein-rich food, especially dry-cured meat products. The assay was based on targeting otapksPN gene, a key gene in the biosynthesis of ochratoxin A (OTA) in P. nordicum. Amplification of DNA during the reaction was detected directly in-tube by color transition of hydroxynaphthol blue from violet to sky blue, visible to the naked eye, avoiding further post amplification analyses. Only DNAs isolated from several P. nordicum strains led to positive results and no amplification was observed from non-target OTA and non OTA-producing strains. The assay was able to detect down to 100 fg of purified targeted genomic DNA or 10(2) conidia/reaction within 60 min. The LAMP assay for detection and identification of P. nordicum was combined with a rapid DNA extraction method set up on serially diluted conidia, providing an alternative rapid, specific and sensitive DNA-based method suitable for application directly "on-site", notably in key steps of dry-cured meat production. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Rapid colorimetric assay for detection of Listeria monocytogenes in food samples using LAMP formation of DNA concatemers and gold nanoparticle-DNA probe complex

    NASA Astrophysics Data System (ADS)

    Wachiralurpan, Sirirat; Sriyapai, Thayat; Areekit, Supatra; Sriyapai, Pichapak; Augkarawaritsawong, Suphitcha; Santiwatanakul, Somchai; Chansiri, Kosum

    2018-04-01

    ABSTRACT Listeria monocytogenes is a major foodborne pathogen of global health concern. Herein, the rapid diagnosis of L. monocytogenes has been achieved using loop-mediated isothermal amplification (LAMP) based on the phosphatidylcholine-phospholipase C gene (plcB). Colorimetric detection was then performed through the formation of DNA concatemers and a gold nanoparticle/DNA probe complex (GNP/DNA probe). The overall detection process was accomplished within approximately 1 h with no need for complicated equipment. The limits of detection for L. monocytogenes in the forms of purified genomic DNA and pure culture were 800 fg and 2.82 CFU mL-1, respectively. No cross reactions were observed from closely related bacteria species. The LAMP-GNP/DNA probe assay was applied to the detection of 200 raw chicken meat samples and compared to routine standard methods. The data revealed that the specificity, sensitivity and accuracy were 100%, 90.20% and 97.50%, respectively. The present assay was 100% in conformity with LAMP-agarose gel electrophoresis assay. Five samples that were negative by both assays appeared to have the pathogen at below the level of detection. The assay can be applied as a rapid direct screening method for L. monocytogenes.

  15. Rapid in situ assessment for predicting soil quality using an algae-soaked disc seeding assay.

    PubMed

    Nam, Sun-Hwa; Moon, Jongmin; Kim, Shin Woong; Kim, Hakyeong; Jeong, Seung-Woo; An, Youn-Joo

    2017-11-16

    The soil quality of remediated land is altered and this land consequently exerts unexpected biological effects on terrestrial organisms. Therefore, field evaluation of such land should be conducted using biological indicators. Algae are a promising new biological indicator since they are a food source for organisms in higher soil trophic levels and easily sampled from the soil. Field evaluation of soil characteristics is preferred to be testing in laboratory conditions because many biological effects cannot be duplicated during laboratory evaluations. Herein, we describe a convenient and rapid algae-soaked disc seeding assay for assessing soil quality in the field based on soil algae. The collection of algae is easy and rapid and the method predicts the short-term quality of contaminated, remediated, and amended farm and paddy soils. The algae-soaked disc seeding assay is yet to be extensively evaluated, and the method cannot be applied to loamy sand soil in in situ evaluations. The algae-soaked disc seeding assay is recommended for prediction of soil quality in in situ evaluations because it reflects all variations in the environment. The algae-soaked disc seeding assay will help to develop management strategies for in situ evaluation.

  16. An isothermal based recombinase polymerase amplification assay for rapid, sensitive and robust indexing of citrus yellow mosaic virus.

    PubMed

    Kumar, P V; Sharma, S K; Rishi, N; Ghosh, D K; Baranwal, V K

    Management of viral diseases relies on definite and sensitive detection methods. Citrus yellow mosaic virus (CYMV), a double stranded DNA virus of the genus Badnavirus, causes yellow mosaic disease in citrus plants. CYMV is transmitted through budwood and requires a robust and simplified indexing protocol for budwood certification programme. The present study reports development and standardization of an isothermal based recombinase polymerase amplification (RPA) assay for a sensitive, rapid, easy, and cost-effective method for detection and diagnosis of CYMV. Two different oligonucleotide primer sets were designed from ORF III (coding for polyprotein) and ORF II (coding for virion associated protein) regions of CYMV to perform amplification assays. Comparative evaluation of RPA, PCR and immuno-capture recombinase polymerase amplification (IC-RPA) based assays were done using purified DNA and plant crude sap. CYMV infection was efficiently detected from the crude sap in RPA and IC-RPA assays. The primer set used in RPA was specific and did not show any cross-amplification with banana streak MY virus (BSMYV), another Badnavirus species. The results from the present study indicated that RPA assay can be used easily in routine indexing of citrus planting material. To the best of our knowledge, this is the first report on development of a rapid and simplified isothermal detection assay for CYMV and can be utilized as an effective technique in quarantine and budwood certification process.

  17. Rapid visual detection of cyprinid herpesvirus 2 by recombinase polymerase amplification combined with a lateral flow dipstick.

    PubMed

    Wang, H; Sun, M; Xu, D; Podok, P; Xie, J; Jiang, Ys; Lu, Lq

    2018-05-28

    Herpesviral haematopoietic necrosis (HVHN), caused by cyprinid herpesvirus 2 (CyHV-2), causes significant losses in crucian carp (Carassius carassius) aquaculture. Rapid and convenient DNA assay detection of CyHV-2 is useful for field diagnosis. Recombinase polymerase amplification (RPA) is a novel isothermal DNA amplification and detection technology that can amplify DNA within 30 min at ~37°C by simulating in vivo DNA recombination. Herein, a rapid and convenient detection assay based on RPA with a lateral flow dipstick (LFD) was developed for detecting CyHV-2. The highly conserved ORF72 of CyHV-2 was targeted by specific and sensitive primers and probes. The optimized assay takes only 15 min at 38°C using a water bath, with analysis of products by 2% agarose gel electrophoresis within 30 min. A simple lateral flow strip based on the unique probe in reaction buffer was developed for visualization. The entire RPA-LFD assay takes 50 min less than the routine PCR method, is 100 times more sensitive and displays no cross-reaction with other aquatic viruses. The combined isothermal RPA and lateral flow assay (RPA-LFD) provides a simple, rapid, reliable method that could improve field diagnosis of CyHV-2 when resources are limited. © 2018 John Wiley & Sons Ltd.

  18. Rapid diagnostic methods for influenza virus in clinical specimens - A comparative study

    NASA Technical Reports Server (NTRS)

    Evans, A. S.; Olson, B.

    1982-01-01

    A comparison of five rapid viral diagnostic techniques for identifying influenza virus in nasopharyngeal aspirates has been made on patients with influenza-like illnesses. Initial results with immune electron microscopy were positive in only one of 11 specimens from which virus was isolated and further work abandoned. Four other rapid tests were carried out on 39 specimens from which influenza virus had been isolated in tissue culture in 28. Of these 28 specimens yielding virus, 24 (85.7 percent) were positive by an indirect fluorescent antibody test (IFAT) on nasopharyngeal cells, 18 (64.3 percent) by enzyme-linked immunosorbent assay (ELISA), 19 (67.8 percent) by enzyme-linked fluorescent assay (ELFA), and 26 (92.8 percent) by a rapid tissue culture amplification method (TCA) in a continuous Rhesus monkey kidney line (LLC-MK2) with identification of virus by fluorescent antibody. In terms of sensitivity, simplicity, and rapidity, a combination of the IFAT and TCA methods seems to be very useful.

  19. Simple and rapid silver nanoparticles based antioxidant capacity assays: Reactivity study for phenolic compounds.

    PubMed

    Della Pelle, Flavio; Scroccarello, Annalisa; Sergi, Manuel; Mascini, Marcello; Del Carlo, Michele; Compagnone, Dario

    2018-08-01

    A single-step, rapid (10 min), sensitive silver nanoparticles (AgNPs) based spectrophotometric method for antioxidant capacity (AOC) assay has been developed. The assay is based on the ability of natural polyphenols to reduce Ag(I) and stabilize the produced AgNPs(0) at room temperature. Localized surface plasmon resonance (LSPR) of AgNPs at ≈420 nm is then measured. Using different conditions of pH (8.4) and temperature (45 °C) a further assay based on the production of AgNPs with selectivity for flavonols was also developed. The reactivity of the two AgNPs based assays vs. 15 polyphenols belonging to different chemical classes and 9 different samples has been studied and compared with ABTS, Folin and AuNPs based methods for AOC. The proposed assays had good reproducibility (RSD ≤ 13) and are simple, sensitive and cost effective. Moreover, used in conjunction with the classical AOC assays, can improve the information on the polyphenolic pool of food samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. A Universally Applicable and Rapid Method for Measuring the Growth of Streptomyces and Other Filamentous Microorganisms by Methylene Blue Adsorption-Desorption

    PubMed Central

    Fischer, Marco

    2013-01-01

    Quantitative assessment of growth of filamentous microorganisms, such as streptomycetes, is generally restricted to determination of dry weight. Here, we describe a straightforward methylene blue-based sorption assay to monitor microbial growth quantitatively, simply, and rapidly. The assay is equally applicable to unicellular and filamentous bacterial and eukaryotic microorganisms. PMID:23666340

  1. A review of Cry protein detection with enzyme-linked immunosorbent assays

    USDA-ARS?s Scientific Manuscript database

    Several detection methods are available to monitor the fate of Cry proteins in the environment, enzyme-linked immunosorbent assays (ELISAs) have emerged as the preferred detection method, due to their cost-effectiveness, ease of use, and rapid results. Validation of ELISAs is necessary to ensure acc...

  2. Accelerated Colorimetric Micro-assay for Screening Mold Inhibitors

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2014-01-01

    Rapid quantitative laboratory test methods are needed to screen potential antifungal agents. Existing laboratory test methods are relatively time consuming, may require specialized test equipment and rely on subjective visual ratings. A quantitative, colorimetric micro-assay has been developed that uses XTT tetrazolium salt to metabolically assess mold spore...

  3. Quantitative detection of crystalline lysine supplementation in poultry feeds using a rapid bacterial bioluminescence assay.

    PubMed

    Zabala Díaz, I B; Ricke, S C

    2003-08-01

    Lysine is an essential amino acid for both humans and animals; and it is usually the first or second limiting amino acid in most formulated diets. In order to estimate the lysine content in feeds and feed sources, rapid amino acid bioassays have been developed. The objective of this work is to assess a rapid assay for lysine supplementation in chicken feeds, using a luminescent Escherichia coli lysine-auxotrophic strain, to avoid prior thermal sterilization. An E. coli lysine auxotroph carrying a plasmid with lux genes was used as the test organism. The lysine assay was conducted using depleted auxotrophic cells in lysine samples. Luminescence was measured with a Dynex MLX luminometer after addition of the aldehyde substrate. Growth response (monitored as optical density at 600 nm) and light emission response of the assay E. coli strain were monitored to generate standard curves. Bioluminescent analysis of feed samples indicated that the method works well in the presence of a complex feed matrix. Comparison of both optical density and luminescent-based methods indicated that, when the assay takes place under optimal conditions, both methodologies correlated well ( r(2)=0.99). Except for the 0.64% lysine-supplemented feed, estimates for lysine based on the bacterial assay were over 80% (82-97%) of the theoretical values. Animal data showed that the bacterial bioluminescent method correlated well with the chick bioassay when diets with different levels of lysine supplementation were assayed for lysine bioavailability ( r(2)=0.97). Luminescent methodology coupled with a bacterial growth assay is a promising technique to assess lysine availability in supplemented animal feeds.

  4. Rapid and accurate detection of KRAS mutations in colorectal cancers using the isothermal-based optical sensor for companion diagnostics

    PubMed Central

    Koo, Bonhan; Lee, Tae Yoon; Lee, Jeong Hoon; Shin, Yong; Lim, Seok-Byung

    2017-01-01

    Although KRAS mutational status testing is becoming a companion diagnostic tool for managing patients with colorectal cancer (CRC), there are still several difficulties when analyzing KRAS mutations using the existing assays, particularly with regard to low sensitivity, its time-consuming, and the need for large instruments. We developed a rapid, sensitive, and specific mutation detection assay based on the bio-photonic sensor termed ISAD (isothermal solid-phase amplification/detection), and used it to analyze KRAS gene mutations in human clinical samples. To validate the ISAD-KRAS assay for use in clinical diagnostics, we examined for hotspot KRAS mutations (codon 12 and codon 13) in 70 CRC specimens using PCR and direct sequencing methods. In a serial dilution study, ISAD-KRAS could detect mutations in a sample containing only 1% of the mutant allele in a mixture of wild-type DNA, whereas both PCR and direct sequencing methods could detect mutations in a sample containing approximately 30% of mutant cells. The results of the ISAD-KRAS assay from 70 clinical samples matched those from PCR and direct sequencing, except in 5 cases, wherein ISAD-KRAS could detect mutations that were not detected by PCR and direct sequencing. We also found that the sensitivity and specificity of ISAD-KRAS were 100% within 30 min. The ISAD-KRAS assay provides a rapid, highly sensitive, and label-free method for KRAS mutation testing, and can serve as a robust and near patient testing approach for the rapid detection of patients most likely to respond to anti-EGFR drugs. PMID:29137388

  5. The impact of commercial rapid respiratory virus diagnostic tests on patient outcomes and health system utilization.

    PubMed

    Ko, Fiona; Drews, Steven J

    2017-10-01

    Acute respiratory tract infections due to influenza A/B and respiratory syncytial virus (RSV) are major causes of morbidity and mortality globally. Rapid tests for detection of these pathogens include antigen detection point of care tests (POC) and newer easy to use molecular tests. From experience, these assays improve both laboratory workflow and assay interpretation issues. However, the question of the benefits of using rapid test technology compared to routine laboratory testing for respiratory viral pathogens is still often asked. Areas covered: Specifically, this review aims to; 1) identify clinical/patient indicators that can be measured prior to and following the implementation of rapid diagnostic test for influenza and RSV, 2) provide multiple perspectives on the extent of impact of a rapid diagnostic test, including direct and indirect outcomes, and 3) identify the technological advancements in the development of rapid testing, demonstrating a timeline that transitions from antigen-based assays to molecular assays. Expert commentary: Key benefits to the use of either antigen-based or molecular rapid tests for patient care, patient flow within institutions, as well as laboratory utilization are identified. Due to improved test characteristics, the authors feel that rapid molecular tests have greater benefits than antigen-based detection methods.

  6. Development of a nematode offspring counting assay for rapid and simple soil toxicity assessment.

    PubMed

    Kim, Shin Woong; Moon, Jongmin; Jeong, Seung-Woo; An, Youn-Joo

    2018-05-01

    Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. PCR-Based Method for Detecting Viral Penetration of Medical Exam Gloves

    PubMed Central

    Broyles, John M.; O'Connell, Kevin P.; Korniewicz, Denise M.

    2002-01-01

    The test approved by the U.S. Food and Drug Administration for assessment of the barrier quality of medical exam gloves includes visual inspection and a water leak test. Neither method tests directly the ability of gloves to prevent penetration by microorganisms. Methods that use microorganisms (viruses and bacteria) to test gloves have been developed but require classical culturing of the organism to detect it. We have developed a PCR assay for bacteriophage φX174 that allows the rapid detection of penetration of gloves by this virus. The method is suitable for use with both latex and synthetic gloves. The presence of glove powder on either latex or synthetic gloves had no effect on the ability of the PCR assay to detect bacteriophage DNA. The assay is rapid, sensitive, and inexpensive; requires only small sample volumes; and can be automated. PMID:12149320

  8. A homogeneous biochemiluminescent assay for detection of influenza

    NASA Astrophysics Data System (ADS)

    Hui, Kwok Min; Li, Xiao Jing; Pan, Lu; Li, X. J.

    2015-05-01

    Current methods of rapid detection of influenza are based on detection of the nucleic acids or antigens of influenza viruses. Since influenza viruses constantly mutate leading to appearance of new strains or variants of viruses, these detection methods are susceptible to genetic changes in influenza viruses. Type A and B influenza viruses contain neuraminidase, an essential enzyme for virus replication which enables progeny influenza viruses leave the host cells to infect new cells. Here we describe an assay method, the homogeneous biochemiluminescent assay (HBA), for rapid detection of influenza by detecting viral neuraminidase activity. The assay mimics the light production process of a firefly: a viral neuraminidase specific substrate containing a luciferin moiety is cleaved in the presence of influenza virus to release luciferin, which becomes a substrate to firefly luciferase in a light production system. All reagents can be formulated in a single reaction mix so that the assay involves only one manual step, i.e., sample addition. Presence of Type A or B influenza virus in the sample leads to production of strong, stable and easily detectable light signal, which lasts for hours. Thus, this influenza virus assay is suitable for use in point-of-care settings.

  9. Candida albicans Germ-Tube Antibody: Evaluation of a New Automatic Assay for Diagnosing Invasive Candidiasis in ICU Patients.

    PubMed

    Parra-Sánchez, Manuel; Zakariya-Yousef Breval, Ismail; Castro Méndez, Carmen; García-Rey, Silvia; Loza Vazquez, Ana; Úbeda Iglesias, Alejandro; Macías Guerrero, Desiree; Romero Mejías, Ana; León Gil, Cristobal; Martín-Mazuelos, Estrella

    2017-08-01

    Testing for Candida albicans germ-tube antibody IFA IgG assay (CAGTA) is used to detect invasive candidiasis infection. However, most suitable assays lack automation and rapid single-sample testing. The CAGTA assay was adapted in an automatic monotest system (invasive candidiasis [CAGTA] VirClia ® IgG monotest (VirClia ® ), a chemiluminescence assay with ready-to-use reagents that provides a rapid objective result. CAGTA assay was compared with the monotest automatic VirClia ® assay in order to establish the diagnostic reliability, accuracy, and usefulness of this method. A prospective study with 361 samples from 179 non-neutropenic critically ill adults patients was conducted, including 21 patients with candidemia, 18 with intra-abdominal candidiasis, 84 with Candida spp. colonization, and 56 with culture-negative samples, as well as samples from ten healthy subjects. Overall agreement between the two assays (CAGTA and VirCLIA) was 85.3%. These assays were compared with the gold-standard method to determine the sensitivity, specificity as well as positive and negative predictive values. In patients with candidemia, values for CAGTA and VirCLIA assays were 76.2 versus 85.7%, 80.3 versus 75.8%, 55.2 versus 52.9%, and 91.4 versus 94.3%, respectively. The corresponding values in patients with intra-abdominal candidiasis were 61.1 versus 66.7%, 80.3 versus 75.8%, 45.8 versus 42.9%, and 88.3 versus 89.3%, respectively. No differences were found according to the species of Candida isolated in culture, except for Candida albicans and C. parapsilosis, for which VirClia ® was better than CAGTA. According to these results, the automated VirClia ® assay was a reliable, rapid, and very easy to perform technique as tool for the diagnosis invasive candidiasis.

  10. Quantitative methylene blue decolourisation assays as rapid screening tools for assessing the efficiency of catalytic reactions.

    PubMed

    Kruid, Jan; Fogel, Ronen; Limson, Janice Leigh

    2017-05-01

    Identifying the most efficient oxidation process to achieve maximum removal of a target pollutant compound forms the subject of much research. There exists a need to develop rapid screening tools to support research in this area. In this work we report on the development of a quantitative assay as a means for identifying catalysts capable of decolourising methylene blue through the generation of oxidising species from hydrogen peroxide. Here, a previously described methylene blue test strip method was repurposed as a quantitative, aqueous-based spectrophotometric assay. From amongst a selection of metal salts and metallophthalocyanine complexes, monitoring of the decolourisation of the cationic dye methylene blue (via Fenton-like and non-Fenton oxidation reactions) by the assay identified the following to be suitable oxidation catalysts: CuSO 4 (a Fenton-like catalyst), iron(II)phthalocyanine (a non-Fenton oxidation catalyst), as well as manganese(II) phthalocyanine. The applicability of the method was examined for the removal of bisphenol A (BPA), as measured by HPLC, during parallel oxidation experiments. The order of catalytic activity was identified as FePc > MnPc > CuSO 4 for both BPA and MB. The quantitative MB decolourisation assay may offer a rapid method for screening a wide range of potential catalysts for oxidation processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Nanocolloidal gold-based immuno-dip strip assay for rapid detection of Sudan red I in food samples.

    PubMed

    Wang, Jia; Wang, Zhanhui; Liu, Jing; Li, Hao; Li, Qing X; Li, Ji; Xu, Ting

    2013-02-15

    A semiquantitative dip strip assay was developed using nanocolloidal gold-labelled monoclonal antibody (Mab) 8A10 for the rapid detection of Sudan red I in food samples. A protein-Sudan red I conjugate was coated on a nitro cellulose membrane strip in a defined test line. In flow of the complex of nanocolloidal gold labelled-Mab and Sudan red I along the strip, intensive red colour that was formed in the test line reflected the Sudan red I concentration. The test required 10 min and had a visual limit of detection of 10 ng/g Sudan red I in tomato sauce and chilli powder samples. The results of the strip assay agreed well with those of a high performance liquid chromatography method for both spiked and real commercial samples. The strip was stable for at least 2 months at 4°C. The strip assay offers the potential as a useful rapid and simple method for screening of Sudan red I in food samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. [Rapid bioluminescent antibiotic susceptibility assay].

    PubMed

    Frundzhian, V G; Ugarova, N N; Blatun, L A; Terekhova, R P; Rusanova, E V

    2009-01-01

    Rapid testing of pathogen susceptibility to antibiotics is of great practical value for rational chemotherapy of pyoinflammatory deseases and postoperative complications of microbial etiology. The standard microbiological methods, i.e., the disk diffusion method and the method of serial dilutions are labour- and time-consuming (not less than 18-36 hours). The method of the authors is based on measuring bioluminescence resulting from interaction of adenosine-5'-triphosphate (ATP) and ATP reagent, a standard reaction mixture of firefly luciferase (an enzyme) and luciferin. The bioluminescence intensity is proportional to the ATP concentration in the reaction mixture and the ATP concentration is proportional to the number of the pathogen viable cells in the sample. The bioluminescence intensity value in the pathogen suspension aliquots with and without (control) the antibiotic were compared after the incubation for 5 hours and the coefficient of the microbial cell growth inhibition was calculated. Satisfactory correlation (R2 > 88%) of the results of the bioluminescent assay and the assay with the disk diffusion method and the method of serial dilutions was observed.

  13. Recombinase polymerase amplification combined with a lateral flow dipstick for rapid and visual detection of Schistosoma japonicum.

    PubMed

    Sun, Kui; Xing, Weiwei; Yu, Xinling; Fu, Wenliang; Wang, Yuanyuan; Zou, Minji; Luo, Zhihong; Xu, Donggang

    2016-08-31

    With the continuous decline in prevalence and intensity of Schistosoma japonicum infection in China, more accurate and sensitive methods suitable for field detection become much needed for schistosomiasis control. Here, a novel rapid and visual detection method based on the combination of recombinase polymerase amplification (RPA) and lateral flow dipstick (LFD) was developed to detect S. japonicum DNA in fecal samples. The LFD-RPA assay targeting SjR2 could detect 5 fg S. japonicum DNA, which was identical to qPCR and real-time RPA assay, and showed no cross-reaction with other parasites. The detection could be finished within 15-20 min at a wide temperature range (25-45 °C), and the results could be visualized by naked eye. The diagnostic validity of LFD-RPA assay was further assessed with 14 fecal samples of infected patients diagnosed by Kato-Katz method and 31 fecal samples of healthy persons, and compared with that of Enzyme-linked immunosorbent assay (ELSIA) and Indirect Hemagglutination Assay (IHA). The LFD-RPA assay showed 92.68 % sensitivity, 100 % specificity and excellent diagnostic agreement with the gold standard Kato-Katz test (k = 0.947, Z = 6.36, P < 0.001), whereas ELISA showed 85.71 % sensitivity, 93.55 % specificity, and substantial diagnostic agreement (k = 0.793, Z = 5.31, P < 0.001), and IHA showed 78.57 % sensitivity, 83.87 % specificity, and moderate diagnostic agreement (k = 0.600, Z = 4.05, P < 0.001), indicating that the LFD-RPA was much better than the traditional methods. The LFD-RPA assay established by us is a sensitive, specific, rapid and convenient method for the diagnosis of schistosomiasis, and shows a great potency in field application.

  14. Low-Cost HIV-1 Diagnosis and Quantification in Dried Blood Spots by Real Time PCR

    PubMed Central

    Mehta, Nishaki; Trzmielina, Sonia; Nonyane, Bareng A. S.; Eliot, Melissa N.; Lin, Rongheng; Foulkes, Andrea S.; McNeal, Kristina; Ammann, Arthur; Eulalievyolo, Vindu; Sullivan, John L.; Luzuriaga, Katherine; Somasundaran, Mohan

    2009-01-01

    Background Rapid and cost-effective methods for HIV-1 diagnosis and viral load monitoring would greatly enhance the clinical management of HIV-1 infected adults and children in limited-resource settings. Recent recommendations to treat perinatally infected infants within the first year of life are feasible only if early diagnosis is routinely available. Dried blood spots (DBS) on filter paper are an easy and convenient way to collect and transport blood samples. A rapid and cost effective method to diagnose and quantify HIV-1 from DBS is urgently needed to facilitate early diagnosis of HIV-1 infection and monitoring of antiretroviral therapy. Methods and Findings We have developed a real-time LightCycler (rtLC) PCR assay to detect and quantify HIV-1 from DBS. HIV-1 RNA extracted from DBS was amplified in a one-step, single-tube system using primers specific for long-terminal repeat sequences that are conserved across all HIV-1 clades. SYBR Green dye was used to quantify PCR amplicons and HIV-1 RNA copy numbers were determined from a standard curve generated using serially diluted known copies of HIV-1 RNA. This assay detected samples across clades, has a dynamic range of 5 log10, and %CV <8% up to 4 log10 dilution. Plasma HIV-1 RNA copy numbers obtained using this method correlated well with the Roche Ultrasensitive (r = 0.91) and branched DNA (r = 0.89) assays. The lower limit of detection (95%) was estimated to be 136 copies. The rtLC DBS assay was 2.5 fold rapid as well as 40-fold cheaper when compared to commercial assays. Adaptation of the assay into other real-time systems demonstrated similar performance. Conclusions The accuracy, reliability, genotype inclusivity and affordability, along with the small volumes of blood required for the assay suggest that the rtLC DBS assay will be useful for early diagnosis and monitoring of pediatric HIV-1 infection in resource-limited settings. PMID:19503790

  15. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe

    PubMed Central

    Xue, Yong; Wilkes, Jon G.; Moskal, Ted J.; Williams, Anna J.; Cooper, Willie M.; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A.

    2016-01-01

    Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts. PMID:26913737

  16. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe.

    PubMed

    Xue, Yong; Wilkes, Jon G; Moskal, Ted J; Williams, Anna J; Cooper, Willie M; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A

    2016-01-01

    Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts.

  17. Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay

    PubMed Central

    Zhao, Yong; Wang, Haoran; Zhang, Pingping; Sun, Chongyun; Wang, Xiaochen; Wang, Xinrui; Yang, Ruifu; Wang, Chengbin; Zhou, Lei

    2016-01-01

    The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 104 CFU mL−1 or 105 CFU mL−1 for each pathogen, and after sample enrichment it was 10 CFU/0.6 mg. The assay also showed good linearity, allowing quantitative detection, with a linear fitting coefficient of determination (R2) of 0.916–0.998. The 10 detection channels did not cross-react, so multiple targets could be specifically detected. When 279 real food samples were tested, the assay was highly consistent (100%) with culture-based methods. The results for 110 food samples artificially contaminated with single or multiple targets showed a high detection rate (≥80%) for most target bacteria. Overall, the TC-UPT-LF assay allows the rapid, quantitative, and simultaneous detection of 10 kinds of foodborne pathogens within 20 min, and is especially suitable for the rapid detection and surveillance of foodborne pathogens in food and water. PMID:26884128

  18. Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay.

    PubMed

    Zhao, Yong; Wang, Haoran; Zhang, Pingping; Sun, Chongyun; Wang, Xiaochen; Wang, Xinrui; Yang, Ruifu; Wang, Chengbin; Zhou, Lei

    2016-02-17

    The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 10(4) CFU mL(-1) or 10(5) CFU mL(-1) for each pathogen, and after sample enrichment it was 10 CFU/0.6 mg. The assay also showed good linearity, allowing quantitative detection, with a linear fitting coefficient of determination (R(2)) of 0.916-0.998. The 10 detection channels did not cross-react, so multiple targets could be specifically detected. When 279 real food samples were tested, the assay was highly consistent (100%) with culture-based methods. The results for 110 food samples artificially contaminated with single or multiple targets showed a high detection rate (≥ 80%) for most target bacteria. Overall, the TC-UPT-LF assay allows the rapid, quantitative, and simultaneous detection of 10 kinds of foodborne pathogens within 20 min, and is especially suitable for the rapid detection and surveillance of foodborne pathogens in food and water.

  19. Evaluation of antimicrobial activity of selected plant extracts by rapid XTT colorimetry and bacterial enumeration.

    PubMed

    Al-Bakri, Amal G; Afifi, Fatma U

    2007-01-01

    The aim of this study was to screen and evaluate the antimicrobial activity of indigenous Jordanian plant extracts, dissolved in dimethylsulfoxide, using the rapid XTT assay and viable count methods. XTT rapid assay was used for the initial screening of antimicrobial activity for the plant extracts. Antimicrobial activity of potentially active plant extracts was further assessed using the "viable plate count" method. Four degrees of antimicrobial activity (high, moderate, weak and inactive) against Bacillus subtilis, Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa, respectively, were recorded. The plant extracts of Hypericum triquetrifolium, Ballota undulata, Ruta chalepensis, Ononis natrix, Paronychia argentea and Marrubium vulgare had shown promising antimicrobial activity. This study showed that while both XTT and viable count methods are comparable when estimating the overall antimicrobial activity of experimental substances, there is no strong linear correlation between the two methods.

  20. Development of a Reverse Transcription Loop-Mediated Isothermal Amplification Method for the Rapid Detection of Subtype H7N9 Avian Influenza Virus

    PubMed Central

    Bao, Hongmei; Zhao, Yuhui; Wang, Yunhe; Xu, Xiaolong; Shi, Jianzhong; Zeng, Xianying; Wang, Xiurong; Chen, Hualan

    2014-01-01

    A novel influenza A (H7N9) virus has emerged in China. To rapidly detect this virus from clinical samples, we developed a reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of the H7N9 virus. The minimum detection limit of the RT-LAMP assay was 0.01 PFU H7N9 virus, making this method 100-fold more sensitive to the detection of the H7N9 virus than conventional RT-PCR. The H7N9 virus RT-LAMP assays can efficiently detect different sources of H7N9 influenza virus RNA (from chickens, pigeons, the environment, and humans). No cross-reactive amplification with the RNA of other subtype influenza viruses or of other avian respiratory viruses was observed. The assays can effectively detect H7N9 influenza virus RNA in drinking water, soil, cloacal swab, and tracheal swab samples that were collected from live poultry markets, as well as human H7N9 virus, in less than 30 min. These results suggest that the H7N9 virus RT-LAMP assays were efficient, practical, and rapid diagnostic methods for the epidemiological surveillance and diagnosis of influenza A (H7N9) virus from different resource samples. PMID:24689044

  1. Multiplex PCR for rapid diagnosis and differentiation of pox and pox-like diseases in dromedary Camels.

    PubMed

    Khalafalla, Abdelmalik I; Al-Busada, Khalid A; El-Sabagh, Ibrahim M

    2015-07-07

    Pox and pox-like diseases of camels are a group of exanthematous skin conditions that have become increasingly important economically. Three distinct viruses may cause them: camelpox virus (CMLV), camel parapox virus (CPPV) and camelus dromedary papilloma virus (CdPV). These diseases are often difficult to differentiate based on clinical presentation in disease outbreaks. Molecular methods such as PCR targeting species-specific genes have been developed and used to identify these diseases, but not simultaneously in a single tube. Recently, multiplex PCR has gained reputation as a convenient diagnostic method with cost-and timesaving benefits. In the present communication, we describe the development, optimization and validation of a multiplex PCR assay able to detect simultaneously the genome of the three viruses in one single test allowing for rapid and efficient molecular diagnosis. The assay was developed based on the evaluation and combination of published and new primer sets and was validated with viral genomic DNA extracted from known virus strains (n = 14) and DNA extracted from homogenized clinical skin specimens (n = 86). The assay detects correctly the target pathogens by amplification of targeted genes, even in case of co-infection. The method showed high sensitivity, and the specificity was confirmed by PCR-product sequencing. This assay provide rapid, sensitive and specific method for identifying three important viruses in specimens collected from dromedary camels with varying clinical presentations.

  2. A Rapid and Specific Assay for the Detection of MERS-CoV

    PubMed Central

    Huang, Pei; Wang, Hualei; Cao, Zengguo; Jin, Hongli; Chi, Hang; Zhao, Jincun; Yu, Beibei; Yan, Feihu; Hu, Xingxing; Wu, Fangfang; Jiao, Cuicui; Hou, Pengfei; Xu, Shengnan; Zhao, Yongkun; Feng, Na; Wang, Jianzhong; Sun, Weiyang; Wang, Tiecheng; Gao, Yuwei; Yang, Songtao; Xia, Xianzhu

    2018-01-01

    Middle East respiratory syndrome coronavirus (MERS-CoV) is a novel human coronavirus that can cause human respiratory disease. The development of a detection method for this virus that can lead to rapid and accurate diagnosis would be significant. In this study, we established a nucleic acid visualization technique that combines the reverse transcription loop-mediated isothermal amplification technique and a vertical flow visualization strip (RT-LAMP-VF) to detect the N gene of MERS-CoV. The RT-LAMP-VF assay was performed in a constant temperature water bath for 30 min, and the result was visible by the naked eye within 5 min. The RT-LAMP-VF assay was capable of detecting 2 × 101 copies/μl of synthesized RNA transcript and 1 × 101 copies/μl of MERS-CoV RNA. The method exhibits no cross-reactivities with multiple CoVs including SARS-related (SARSr)-CoV, HKU4, HKU1, OC43 and 229E, and thus exhibits high specificity. Compared to the real-time RT-PCR (rRT-PCR) method recommended by the World Health Organization (WHO), the RT-LAMP-VF assay is easy to handle, does not require expensive equipment and can rapidly complete detection within 35 min. PMID:29896174

  3. Use of immunochromatographic assay for rapid identification of Mycobacterium tuberculosis complex from liquid culture

    PubMed Central

    Považan, Anika; Vukelić, Anka; Savković, Tijana; Kurucin, Tatjana

    2012-01-01

    A new, simple immunochromatographic assay for rapid identification of Mycobacterium tuberculosis complex in liquid cultures has been developed. The principle of the assay is binding of the Mycobacterium tuberculosis complex specific antigen to the monoclonal antibody conjugated on the test strip. The aim of this study is evaluation of the performance of immunochromatographic assay in identification of Mycobacterium tuberculosis complex in primary positive liquid cultures of BacT/Alert automated system. A total of 159 primary positive liquid cultures were tested using the immunochromatographic assay (BD MGIT TBc ID) and the conventional subculture, followed by identification using biochemical tests. Of 159 positive liquid cultures, using the conventional method, Mycobacterium tuberculos is was identified in 119 (74.8%), nontuberculous mycobacteria were found in 4 (2.5%), 14 (8.8%) cultures were contaminated and 22 (13.8%) cultures were found to be negative. Using the immunochromatographic assay, Mycobacterium tuberculosis complex was detected in 118 (74.2%) liquid cultures, and 41 (25.8%) tests were negative. Sensitivity, specificity, positive and negative predictive values of the test were 98.3%; 97.5%; 99.15%; 95.12%, respectively. The value of kappa test was 0.950, and McNemar test was 1.00. The immunochromatographic assay is a simple and rapid test which represents a suitable alternative to the conventional subculture method for the primary identification of Mycobacterium tuberculosis complex in liquid cultures of BacT/Alert automated system. PMID:22364301

  4. A real-time loop-mediated isothermal amplification assay for rapid detection of Shigella species.

    PubMed

    Liew, P S; Teh, C S J; Lau, Y L; Thong, K L

    2014-12-01

    Shigellosis is a foodborne illness caused by the genus Shigella and is an important global health issue. The development of effective techniques for rapid detection of this pathogen is essential for breaking the chain of transmission. Therefore, we have developed a novel loop-mediated isothermal amplification (LAMP) assay targeting the invasion plasmid antigen H (ipaH) gene to rapidly detect Shigella species. This assay could be performed in 90 min at an optimal temperature of 64ºC, with endpoint results visualized directly. Notably, the method was found to be more sensitive than conventional PCR. Indeed, the detection limit for the LAMP assay on pure bacterial cultures was 5.9 x 10(5) CFU/ml, while PCR displayed a limit of 5.9 x 10(7) CFU/ml. In spiked lettuce samples, the sensitivity of the LAMP assay was 3.6 x 10(4) CFU/g, whereas PCR was 3.6 x 10(5) CFU/g. Overall, the assay accurately identified 32 Shigella spp. with one enteroinvasive Escherichia coli displaying positive reaction while the remaining 32 non-Shigella strains tested were negative.

  5. Establishment of a multiplex real-time RT-PCR assay for rapid identification of H6 subtype avian influenza viruses.

    PubMed

    Yang, Fan; Wu, Haibo; Liu, Fumin; Lu, Xiangyun; Peng, Xiuming; Wu, Nanping

    2018-06-01

    The H6 subtype avian influenza viruses (AIVs) possess the capacity for zoonotic transmission from avian species to humans. Establishment of a specific, rapid and sensitive method to screen H6 AIVs is necessary. Based on the conserved domain of the matrix and H6 AIV hemagglutinin genes, two TaqMan minor-groove-binder probes and multiplex real-time RT-PCR primers were designed in this study. The multiplex real-time RT-PCR assay developed in this study had high specificity and repeatability and a detection limit of 30 copies per reaction. This rapid diagnostic method will be useful for clinical detection and surveillance of H6 AIVs in China.

  6. Rapid detection of infectious hypodermal and hematopoietic necrosis virus (IHHNV) by real-time, isothermal recombinase polymerase amplification assay.

    PubMed

    Xia, Xiaoming; Yu, Yongxin; Hu, Linghao; Weidmann, Manfred; Pan, Yingjie; Yan, Shuling; Wang, Yongjie

    2015-04-01

    Infectious hypodermal and hematopoietic necrosis virus (IHHNV) causes mortality or runt deformity syndrome in penaeid shrimps and is responsible for significant economic losses in the shrimp aquaculture industry. Here, we describe a novel real-time isothermal recombinase polymerase amplification (RPA) assay developed for IHHNV detection. Using IHHNV plasmid standards and DNA samples from a variety of organisms, we evaluated the ability of the IHHNV-RPA assay to detect IHHNV based on analysis of its sensitivity, specificity, rapidity, and reproducibility. Probit analysis of eight independent experimental replicates indicated satisfactory performance of the RPA assay, which is sufficiently sensitive to detect as few as 4 copies of the IHHNV genome within 7 min at 39 °C with 95 % reliability. Therefore, this rapid RPA method has great potential for applications, either in field use or as a point of care diagnostic technique.

  7. Rapid detection and differentiation of Clonorchis sinensis and Opisthorchis viverrini using real-time PCR and high resolution melting analysis.

    PubMed

    Cai, Xian-Quan; Yu, Hai-Qiong; Li, Rong; Yue, Qiao-Yun; Liu, Guo-Hua; Bai, Jian-Shan; Deng, Yan; Qiu, De-Yi; Zhu, Xing-Quan

    2014-01-01

    Clonorchis sinensis and Opisthorchis viverrini are both important fish-borne pathogens, causing serious public health problem in Asia. The present study developed an assay integrating real-time PCR and high resolution melting (HRM) analysis for the specific detection and rapid identification of C. sinensis and O. viverrini. Primers targeting COX1 gene were highly specific for these liver flukes, as evidenced by the negative amplification of closely related trematodes. Assays using genomic DNA extracted from the two flukes yielded specific amplification and their identity was confirmed by sequencing, having the accuracy of 100% in reference to conventional methods. The assay was proved to be highly sensitive with a detection limit below 1 pg of purified genomic DNA, 5 EPG, or 1 metacercaria of C. sinensis. Moreover, C. sinensis and O. viverrini were able to be differentiated by their HRM profiles. The method can reduce labor of microscopic examination and the contamination of agarose electrophoresis. Moreover, it can differentiate these two flukes which are difficult to be distinguished using other methods. The established method provides an alternative tool for rapid, simple, and duplex detection of C. sinensis and O. viverrini.

  8. Development of single-step multiplex real-time RT-PCR assays for rapid diagnosis of enterovirus 71, coxsackievirus A6, and A16 in patients with hand, foot, and mouth disease.

    PubMed

    Puenpa, Jiratchaya; Suwannakarn, Kamol; Chansaenroj, Jira; Vongpunsawad, Sompong; Poovorawan, Yong

    2017-10-01

    Real-time reverse-transcription polymerase chain reaction (rRT-PCR) to detect enterovirus 71 (EV-A71) and coxsackievirus A16 (CV-A16) has facilitated the rapid and accurate identification of the two most common etiological agents underlying hand, foot, and mouth disease (HFMD). However, the worldwide emergence of CV-A6 infection in HFMD necessitates development of an improved multiplex rRT-PCR method. To rapidly determine the etiology of HFMD, two rRT-PCR assays using TaqMan probes were developed to differentiate among three selected common enteroviruses (EV-A71, CV-A16 and CV-A6) and to enable broad detection of enteroviruses (pan-enterovirus assay). No cross-reactions were observed with other RNA viruses examined. The detection limits of both assays were 10 copies per microliter for EV-A71, CV-A6 and CV-A16, and pan-enterovirus. The methods showed high accuracy (EV-A71, 90.6%; CV-A6, 92.0%; CV-A16, 100%), sensitivity (EV-A71, 96.5%; CV-A6, 95.8%; CV-A16, 99.0%), and specificity (EV-A71, 100%; CV-A6, 99.9%; CV-A16, 99.9%) in testing clinical specimens (n=1049) during 2014-2016, superior to those of conventional RT-PCR. Overall, the multiplex rRT-PCR assays enabled highly sensitive detection and rapid simultaneous typing of EV-A71, CV-A6 and CV-A16, and enteroviruses, rendering them feasible and attractive methods for large-scale surveillance of enteroviruses associated with HFMD outbreaks. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Clover-Tagged Porcine Reproductive and Respiratory Syndrome Virus Infectious Clones for Rapid Detection of Virus Neutralizing Antibodies.

    PubMed

    Huang, Baicheng; Xiao, Xia; Xue, Biyun; Zhou, En-Min

    2018-06-24

    Porcine reproductive and respiratory syndrome (PRRS), caused by the PRRS virus (PRRSV), is a widespread disease that affects domestic pigs of all ages. Accurate and rapid detection of PRRSV specific neutralizing antibodies levels in a pig herd is beneficial for the evaluation of the herd's immunity to combat the specific viral infection. However, the current methods for viral detection, including fluorescent focus neutralization (FFN) and cytopathic effect (CPE) reduction neutralizing assays, are subjective and time-consuming. Therefore, a Clover-tagged PRRSV virus neutralization assay were developed that instrumentally measures the fluorescence signal of Clover stably expressing by a PRRSV infectious clone for at least 10 passages. Herein, the results showed that the proposed Clover-tagged PRRSV neutralization assay is reliable using instrumental measurements of the fluorescence signal of Clover and allows for rapid detection of neutralizing antibodies against PRRSV. The assay was evaluated by testing swine sera from experimental and field samples, and comparisons were made with the traditional FFN and CPE reduction assays. These results suggest that the Clover-tagged PRRSV infectious clone offers a fast and reliable testing method for neutralizing antibodies and could permit high-throughput screening of new antiviral agents. Copyright © 2018. Published by Elsevier B.V.

  10. A rapid method for infectivity titration of Andes hantavirus using flow cytometry.

    PubMed

    Barriga, Gonzalo P; Martínez-Valdebenito, Constanza; Galeno, Héctor; Ferrés, Marcela; Lozach, Pierre-Yves; Tischler, Nicole D

    2013-11-01

    The focus assay is currently the most commonly used technique for hantavirus titer determination. This method requires an incubation time of between 5 and 11 days to allow the appearance of foci after several rounds of viral infection. The following work presents a rapid Andes virus (ANDV) titration assay, based on viral nucleocapsid protein (N) detection in infected cells by flow cytometry. To this end, an anti-N monoclonal antibody was used that was developed and characterized previously. ANDV N could be detected as early as 6 h post-infection, while viral release was not observed until 24-48 h post-infection. Given that ANDV detection was performed during its first round of infection, a time reduction for titer determination was possible and provided results in only two days. The viral titer was calculated from the percentage of N positive cells and agreed with focus assay titers. Furthermore, the assay was applied to quantify the inhibition of ANDV cell entry by patient sera and by preventing endosome acidification. This novel hantavirus titration assay is a highly quantitative and sensitive tool that facilitates infectivity titration of virus stocks, rapid screening for antiviral drugs, and may be further used to detect and quantify infectious virus in human samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Detection of Streptococcus pyogenes using rapid visual molecular assay.

    PubMed

    Zhao, Xiangna; He, Xiaoming; Li, Huan; Zhao, Jiangtao; Huang, Simo; Liu, Wei; Wei, Xiao; Ding, Yiwei; Wang, Zhaoyan; Zou, Dayang; Wang, Xuesong; Dong, Derong; Yang, Zhan; Yan, Xiabei; Huang, Liuyu; Du, Shuangkui; Yuan, Jing

    2015-09-01

    Streptococcus pyogenes is an increasingly important pathogen in many parts of the world. Rapid and accurate detection of S. pyogenes aids in the control of the infection. In this study, a loop-mediated isothermal amplification (LAMP) assay was developed and validated for the specific detection of S. pyogenes. The assay incorporates two methods: a chromogenic analysis using a calcein/Mn(2+) complex and real-time turbidity monitoring to assess the reaction. Both methods detected the target DNA within 60 min under 64°C isothermal conditions. The assay used specifically designed primers to target spy1258, and correctly identified 111 strains of S. pyogenes and 32 non-S. pyogenes strains, including other species of the genus Streptococcus. Tests using reference strains showed that the LAMP assay was highly specific. The sensitivity of the assay, with a detection limit of 1.49 pg DNA, was 10-fold greater than that of PCR. The LAMP assay established in this study is simple, fast and sensitive, and does not rely upon any special equipment; thus, it could be employed in clinical diagnosis. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Establishing a safe, rapid, convenient and low-cost antiviral assay of interferon bioactivity based on recombinant VSV expressing GFP.

    PubMed

    Chen, Weiye; Wen, Zhiyuan; Zhang, Jialin; Li, Cuicui; Huang, Kehe; Bu, Zhigao

    2018-02-01

    The methods of the quantitative assay of the antiviral activity of interferons (IFNs) (type I, II or III) are very important during carrying out of the research of them, since they were found. Here a recombinant vesicular stomatitis virus expressing green fluorescent protein (GFP) (VSV/GFP) and MDBK cells were used to develop an antiviral assay (AVA) for IFNs. This method was carried out on a 96-well cell culture plate, and the half reduction of virus replication was quantified by assaying GFP. To quantify GFP, cell lysis buffer was directly added to the wells infected with VSV/GFP to lyse cells, the VSV/GFP was then inactivated, and relative fluorescence unit (RFU) of GFP was measured and used to calculate the antiviral activity. This method needed only one step instead of three steps in the staining method with naphthol blue black, medium with phenol red can be used, and it had good reproducibility. The GFP-containing samples could be stored at 4°C in a wet box for at least 1 week without affecting the assay results. In addition, the results obtained with this method were similar to those obtained with the staining method. In conclusion, a safe, rapid, convenient and low-cost AVA of IFN based on recombinant VSV/GFP was established. Copyright © 2017. Published by Elsevier B.V.

  13. Evaluation of Colorimetric Methods Using Nicotinamide for Rapid Detection of Pyrazinamide Resistance in Mycobacterium tuberculosis▿

    PubMed Central

    Mirabal, Niuris C.; Yzquierdo, Sergio L.; Lemus, Dihadenys; Madruga, Mariela; Milián, Yoslaine; Echemendía, Miguel; Takiff, Howard; Martin, Anandi; Van der Stuyf, Patrick; Palomino, Juan Carlos; Montoro, Ernesto

    2010-01-01

    The direct detection of pyrazinamide resistance in Mycobacterium tuberculosis is sufficiently difficult that many laboratories do not attempt it. Most pyrazinamide resistance is caused by mutations that inactivate the pyrazinamidase enzyme needed to convert the prodrug pyrazinamide to its active form. We evaluated two newer and simpler methods to assess pyrazinamidase activity, the nitrate reductase and malachite green microtube assays, using nicotinamide in place of pyrazinamide. A total of 102 strains were tested by these methods and the results compared with those obtained by the classic Wayne assay. Mutations in the pncA gene were identified by sequencing the pncA genes from all isolates in which pyrazinamide resistance was detected by any of the three methods. Both the nitrate reductase and malachite green microtube assays showed sensitivities of 93.75% and specificities of 97.67%. Mutations in the pncA gene were found in 14 of 16 strains that were pyrazinamide resistant and in 1 of 4 strains that were sensitive by the Wayne assay. Both of these simple methods, used with nicotinamide, are promising and inexpensive alternatives for the rapid detection of pyrazinamide resistance in limited-resource countries. PMID:20554826

  14. Conventional Rapid Latex Agglutination in Estimation of von Willebrand Factor: Method Revisited and Potential Clinical Applications

    PubMed Central

    Che Hussin, Che Maraina

    2014-01-01

    Measurement of von Willebrand factor antigen (VWF : Ag) levels is usually performed in a specialised laboratory which limits its application in routine clinical practice. So far, no commercial rapid test kit is available for VWF : Ag estimation. This paper discusses the technical aspect of latex agglutination method which was established to suit the purpose of estimating von Willebrand factor (VWF) levels in the plasma sample. The latex agglutination test can be performed qualitatively and semiquantitatively. Reproducibility, stability, linearity, limit of detection, interference, and method comparison studies were conducted to evaluate the performance of this test. Semiquantitative latex agglutination test was strongly correlated with the reference immunoturbidimetric assay (Spearman's rho = 0.946, P < 0.001, n = 132). A substantial agreement (κ = 0.77) was found between qualitative latex agglutination test and the reference assay. Using the scoring system for the rapid latex test, no agglutination is with 0% VWF : Ag (control negative), 1+ reaction is equivalent to <20% VWF : Ag, and 4+ reaction indicates >150% VWF : Ag (when comparing with immunoturbidimetric assay). The findings from evaluation studies suggest that latex agglutination method is suitable to be used as a rapid test kit for the estimation of VWF : Ag levels in various clinical conditions associated with high levels and low levels of VWF : Ag. PMID:25759835

  15. Application of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Cow Components Adulterated in Buffalo Milk/Meat.

    PubMed

    Deb, Rajib; Sengar, Gyanendra Singh; Singh, Umesh; Kumar, Sushil; Alyethodi, R R; Alex, Rani; Raja, T V; Das, A K; Prakash, B

    2016-12-01

    Loop-mediated isothermal amplification (LAMP) is a diagnostic method for amplification of DNA with rapid and minimal equipment requirement. In the present study, we applied the LAMP assay for rapid detection of cow components adulteration in buffalo milk/meat samples. The test can be completed within around 1 h 40 min starting from DNA extraction and can be performed in water bath without requirement of thermocycler. The cow DNA in buffalo samples were identified in the developed LAMP assay by either visualizing with SYBR Green I/HNB dyes or observing the typical ladder pattern on gel electrophoresis. The test can detect up to 5 % level of cow milk/meat mixed in buffalo counterparts. Due to the simplicity and specificity, the developed LAMP test can be easily adapted in any laboratory for rapid detection of cow species identification in livestock by products.

  16. Loop-mediated isothermal amplification assay for rapid detection of Streptococcus agalactiae (group B streptococcus) in vaginal swabs - a proof of concept study.

    PubMed

    McKenna, James Patrick; Cox, Ciara; Fairley, Derek John; Burke, Rachael; Shields, Michael D; Watt, Alison; Coyle, Peter Valentine

    2017-03-01

    Neonatal sepsis caused by Streptococcus agalactiae [group B streptococcus (GBS)] is a life-threatening condition, which is preventable if colonized mothers are identified and given antibiotic prophylaxis during labour. Conventional culture is time consuming and unreliable, and many available non-culture diagnostics are too complex to implement routinely at point of care. Loop-mediated isothermal amplification (LAMP) is a method that, enables the rapid and specific detection of target nucleic acid sequences in clinical materials without the requirement for extensive sample preparation. A prototype LAMP assay targeting GBS sip gene is described. The assay was 100 % specific for GBS, with a limit of detection of 14 genome copies per reaction. The clinical utility of the LAMP assay for rapid direct molecular detection of GBS was determined by testing a total of 157 vaginal swabs with minimal sample processing using a rapid lysis solution. Compared to a reference quantitative real-time PCR assay, the direct LAMP protocol had a sensitivity and specificity of 95.4 and 100 %, respectively, with positive and negative predictive values of 100 and 98.3 %, respectively. Positive and negative likelihood ratios were infinity and 0.05, respectively. The direct LAMP method required a mean time of 45 min from the receipt of a swab to generation of a confirmed result, compared to 2 h 30 min for the reference quantitative real-time PCR test. The direct LAMP protocol described is easy to perform, facilitating rapid and accurate detection of GBS in vaginal swabs. This test has a potential for use at point of care.

  17. Development of a real-time PCR assay with an internal amplification control for detection of Gram-negative histamine-producing bacteria in fish.

    PubMed

    Bjornsdottir-Butler, Kristin; Jones, Jessica L; Benner, Ronald; Burkhardt, William

    2011-05-01

    Prompt detection of bacteria that contribute to scombrotoxin (histamine) fish poisoning can aid in the detection of potentially toxic fish products and prevent the occurrence of illness. We report development of the first real-time PCR method for rapid detection of Gram-negative histamine-producing bacteria (HPB) in fish. The real-time PCR assay was 100% inclusive for detecting high-histamine producing isolates and did not detect any of the low- or non-histamine producing isolates. The efficiency of the assay with/without internal amplification control ranged from 96-104% and in the presence of background flora and inhibitory matrices was 92/100% and 73-96%, respectively. This assay was used to detect HPB from naturally contaminated yellowfin tuna, bluefish, and false albacore samples. Photobacterium damselae (8), Plesiomonas shigelloides (2), Shewanella sp. (1), and Morganella morganii (1) were subsequently isolated from the real-time PCR positive fish samples. These results indicate that the real-time PCR assay developed in this study is a rapid and sensitive method for detecting high-HPB. The assay may be adapted for quantification of HPB, either directly or with an MPN-PCR method. Copyright © 2010. Published by Elsevier Ltd.

  18. A reporter system for replication-competent gammaretroviruses: the inGluc-MLV-DERSE assay

    PubMed Central

    Aloia, Amanda L.; Duffy, Lisa; Pak, Vladimir; Lee, KyeongEun; Sanchez-Martinez, Silvia; Derse, David; Heidecker, Gisela; Cornetta, Kenneth; Rein, Alan

    2012-01-01

    While novel retroviral vectors for use in gene-therapy products are reducing the potential for formation of replication-competent retrovirus (RCR), it remains crucial to screen products for RCR for both research and clinical purposes. For clinical grade gammaretrovirus-based vectors, RCR screening is achieved by an extended S+L− or marker rescue assay, while standard methods for replication-competent lentivirus detection are still in development. In this report, we describe a rapid and sensitive method for replication-competent gammaretrovirus detection. We used this assay to detect three members of the gammaretrovirus family and compared the sensitivity of our assay with well-established methods for retrovirus detection, including the extended S+L− assay. Results presented here demonstrate that this assay should be useful for gene-therapy product testing. PMID:22402321

  19. Development of an immunochromatographic assay for the ß-adrenergic agonist feed additive zilpaterol

    USDA-ARS?s Scientific Manuscript database

    A zilpaterol immunochromatographic assay was developed as an economical and user friendly rapid detection method for zilpaterol. The assay sensitivity was 1.7 – 23.2 ng/g or mL with a variety of feed and animal matrices and did not cross react with clenbuterol or ractopamine. No sample pre-treatme...

  20. Rapid, Efficient Detection and Drug Susceptibility Testing of Mycobacterium tuberculosis in Sputum by Microscopic Observation of Broth Cultures

    PubMed Central

    Caviedes, Luz; Lee, Tien-Shun; Gilman, Robert H.; Sheen, Patricia; Spellman, Emily; Lee, Ellen H.; Berg, Douglas E.; Montenegro-James, Sonia

    2000-01-01

    Inexpensive, rapid, and reliable methods of detecting infection by and drug susceptibility of Mycobacterium tuberculosis (MTB) are crucial to the control of tuberculosis. The novel microscopic observation broth-drug susceptibility assay (MODS) detects early growth of MTB in liquid medium, allowing more timely diagnosis and drug susceptibility testing. Sputum samples from hospitalized patients in Peru were analyzed by using stains, culture, and PCR. Sensitivity of MODS (92%) compared favorably with the most sensitive of the other culture methods (93%). Sputum samples positive for tuberculosis were tested for susceptibility to isoniazid and rifampin with the microwell alamar blue assay (MABA) and MODS. In 89% of cases, there was concordance between MODS and MABA. Of the diagnostic and susceptibility testing methods used, MODS yielded results most rapidly (median, 9.0 and 9.5 days, respectively). MODS is a rapid, inexpensive, sensitive, and specific method for MTB detection and susceptibility testing; it is particularly appropriate for use in developing countries burdened by significant infection rates and increasing numbers of multiple-drug-resistant cases. PMID:10699023

  1. Rapid, efficient detection and drug susceptibility testing of Mycobacterium tuberculosis in sputum by microscopic observation of broth cultures. The Tuberculosis Working Group in Peru.

    PubMed

    Caviedes, L; Lee, T S; Gilman, R H; Sheen, P; Spellman, E; Lee, E H; Berg, D E; Montenegro-James, S

    2000-03-01

    Inexpensive, rapid, and reliable methods of detecting infection by and drug susceptibility of Mycobacterium tuberculosis (MTB) are crucial to the control of tuberculosis. The novel microscopic observation broth-drug susceptibility assay (MODS) detects early growth of MTB in liquid medium, allowing more timely diagnosis and drug susceptibility testing. Sputum samples from hospitalized patients in Peru were analyzed by using stains, culture, and PCR. Sensitivity of MODS (92%) compared favorably with the most sensitive of the other culture methods (93%). Sputum samples positive for tuberculosis were tested for susceptibility to isoniazid and rifampin with the microwell alamar blue assay (MABA) and MODS. In 89% of cases, there was concordance between MODS and MABA. Of the diagnostic and susceptibility testing methods used, MODS yielded results most rapidly (median, 9.0 and 9.5 days, respectively). MODS is a rapid, inexpensive, sensitive, and specific method for MTB detection and susceptibility testing; it is particularly appropriate for use in developing countries burdened by significant infection rates and increasing numbers of multiple-drug-resistant cases.

  2. Rapid detection and quantification of Ebola Zaire virus by one-step real-time quantitative reverse transcription-polymerase chain reaction.

    PubMed

    Ro, Young-Tae; Ticer, Anysha; Carrion, Ricardo; Patterson, Jean L

    2017-04-01

    Given that Ebola virus causes severe hemorrhagic fever in humans with mortality rates as high as 90%, rapid and accurate detection of this virus is essential both for controlling infection and preventing further transmission. Here, a one-step qRT-PCR assay for rapid and quantitative detection of an Ebola Zaire strain using GP, VP24 or VP40 genes as a target is introduced. Routine assay conditions for hydrolysis probe detection were established from the manufacturer's protocol used in the assays. The analytical specificity and sensitivity of each assay was evaluated using in vitro synthesized viral RNA transcripts. The assays were highly specific for the RNA transcripts, no cross-reactivity being observed among them. The limits of detection of the assays ranged from 10 2 to 10 3 copies per reaction. The assays were also evaluated using viral RNAs extracted from cell culture-propagated viruses (Ebola Zaire, Sudan and Reston strains), confirming that they are gene- and strain-specific. The RT-PCR assays detected viral RNAs in blood samples from virus-infected animal, suggesting that they can be also a useful method for identifying Ebola virus in clinical samples. © 2017 The Societies and John Wiley & Sons Australia, Ltd.

  3. Performance assessment of the Capilia TB assay and the BD ProbeTec ET system for rapid culture confirmation of Mycobacterium tuberculosis.

    PubMed

    Wang, Jann-Yuan; Lee, Li-Na; Lai, Hsin-Chih; Hsu, Hsiao-Leng; Jan, I-Shiow; Yu, Chong-Jen; Hsueh, Po-Ren; Yang, Pan-Chyr

    2007-12-01

    Because of the increasing numbers of nontuberculous mycobacterial isolates from clinical specimens, rapid and accurate methods for culture confirmation of Mycobacterium tuberculosis are urgently needed. The study evaluated the performance of the Capilia TB immunochromatographic assay (TAUNS, Numazu, Japan) for culture confirmation of M. tuberculosis using 242 culture-positive liquid media in 2 mycobacterial laboratories from November 2005 to February 2006. Among the 242 samples, 183 were also tested with the BD ProbeTec ET (CTB) assay (Becton Dickinson, Sparks, MD). The results of both assays were compared to the culture results and to each other. The overall sensitivity and specificity of the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 97.3% and 97.1%, respectively. The positive and negative predictive values for the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 98.2% and 95.8%, respectively. Among the 183 samples tested with both assays, 8 had discrepant results, including Capilia-TB-false-positive in 2, CTB-false-positive in another 2, CTB-false-negative in 2, Capilia TB-false-negative in 1, and both assays with false-negative results in the remaining one. This study demonstrated that the Capilia TB assay has a similar diagnostic value with the CTB assay. In addition, with the immunochromatographic method, it is less time-consuming and does not require other laboratory equipment.

  4. Low-cost HIV-1 diagnosis and quantification in dried blood spots by real time PCR.

    PubMed

    Mehta, Nishaki; Trzmielina, Sonia; Nonyane, Bareng A S; Eliot, Melissa N; Lin, Rongheng; Foulkes, Andrea S; McNeal, Kristina; Ammann, Arthur; Eulalievyolo, Vindu; Sullivan, John L; Luzuriaga, Katherine; Somasundaran, Mohan

    2009-06-05

    Rapid and cost-effective methods for HIV-1 diagnosis and viral load monitoring would greatly enhance the clinical management of HIV-1 infected adults and children in limited-resource settings. Recent recommendations to treat perinatally infected infants within the first year of life are feasible only if early diagnosis is routinely available. Dried blood spots (DBS) on filter paper are an easy and convenient way to collect and transport blood samples. A rapid and cost effective method to diagnose and quantify HIV-1 from DBS is urgently needed to facilitate early diagnosis of HIV-1 infection and monitoring of antiretroviral therapy. We have developed a real-time LightCycler (rtLC) PCR assay to detect and quantify HIV-1 from DBS. HIV-1 RNA extracted from DBS was amplified in a one-step, single-tube system using primers specific for long-terminal repeat sequences that are conserved across all HIV-1 clades. SYBR Green dye was used to quantify PCR amplicons and HIV-1 RNA copy numbers were determined from a standard curve generated using serially diluted known copies of HIV-1 RNA. This assay detected samples across clades, has a dynamic range of 5 log(10), and %CV <8% up to 4 log(10) dilution. Plasma HIV-1 RNA copy numbers obtained using this method correlated well with the Roche Ultrasensitive (r = 0.91) and branched DNA (r = 0.89) assays. The lower limit of detection (95%) was estimated to be 136 copies. The rtLC DBS assay was 2.5 fold rapid as well as 40-fold cheaper when compared to commercial assays. Adaptation of the assay into other real-time systems demonstrated similar performance. The accuracy, reliability, genotype inclusivity and affordability, along with the small volumes of blood required for the assay suggest that the rtLC DBS assay will be useful for early diagnosis and monitoring of pediatric HIV-1 infection in resource-limited settings.

  5. Multiplex Immunoassay Profiling.

    PubMed

    Stephen, Laurie

    2017-01-01

    Multiplex immunoassays allow for the rapid profiling of biomarker proteins in biological fluids, using less sample and labor than single immunoassays. This chapter details the methods to develop and manufacture multiplex assays for the Luminex ® platform. Although assay development is not included here, the same methods can be used to covalently couple antibodies to the Luminex beads and to label antibodies for the screening of sandwich pairs, if needed. The assay optimization, detection of cross-reactivity, and minimizing antibody interactions and matrix interferences will be addressed.

  6. ORGANOPHOSPHORUS HYDROLASE-BASED ASSAY FOR ORGANOPHOSPHATE PESTICIDES

    EPA Science Inventory

    We report a rapid and versatile Organophosphorus hydrolase (OPH)-based method for measurement of organophosphates. This assay is based on a substrate-dependent change in pH at the local vicinity of the enzyme. The pH change is monitored using fluorescein isothiocyanate (FITC), ...

  7. The Use of a Simple Enzyme Assay in 'Seed-Hardening' Studies

    ERIC Educational Resources Information Center

    Ead, J.; Devonald, V. G.

    1975-01-01

    Describes a single technique for an enzyme assay of catalase. The method shows that vegetable seeds submitted to pre-sowing 'hardening' cycles of imbition and drying have greater catalase activity and more rapid germination than do the controls. (LS)

  8. Development of one-step quantitative reverse transcription PCR for the rapid detection of flaviviruses.

    PubMed

    Patel, Pranav; Landt, Olfert; Kaiser, Marco; Faye, Oumar; Koppe, Tanja; Lass, Ulrich; Sall, Amadou A; Niedrig, Matthias

    2013-02-14

    The genus Flavivirus includes several pathogenic agents that cause severe illness in humans. Re-emergence of West Nile virus in Europe and continuous spread of certain flaviviruses such as dengue, yellow fever and Japanese encephalitis viruses represent a global danger to public health. Therefore, a rapid and accurate molecular method is required for diagnostics and epidemiological surveillance of flaviviruses. A Pan-Flavi quantitative RT-PCR assay using a Locked-Nucleic Acid probe targeting the flavivirus NS5 gene was developed and optimized to detect a wide range of flaviviruses simultaneously. The specificity and sensitivity of the Pan-Flavi assay were tested using RNA of different flaviviruses and non-flaviviruses. Furthermore, the assay was compared directly to flavivirus species-specific assays for the ability to detect flaviviruses sensitively. Two degenerate primers and one Locked-Nucleic Acids probe were designed to amplify most of the flaviviruses. To increase the specificity and fluorescence signal of the Pan-Flavi assay for detection of yellow fever virus and dengue virus 4, additional primers and probes were included. Viral RNA of thirty different flaviviruses was detected, verifying the broad range specificity. The testing of this assay was successful, using standard plasmid and RNA dilutions of yellow fever virus vaccine strain, dengue virus 1 and tick-borne encephalitis virus, with a sensitivity limit of 10-100 genome copies/reaction. Also comparatively good results were achieved for detecting different flaviviruses by the Pan-Flavi assay when compared to the flavivirus species-specific assays. The assay is rapid, broad-range flavivirus-specific and highly sensitive making it a valuable tool for rapid detection of flaviviruses in livestock samples, epidemiological studies or as useful complement to single flavivirus-specific assays for clinical diagnosis.

  9. Loop-Mediated Isothermal Amplification of the sefA Gene for Rapid Detection of Salmonella Enteritidis and Salmonella Gallinarum in Chickens.

    PubMed

    Gong, Jiansen; Zhuang, Linlin; Zhu, Chunhong; Shi, Shourong; Zhang, Di; Zhang, Linji; Yu, Yan; Dou, Xinhong; Xu, Bu; Wang, Chengming

    2016-04-01

    Salmonella spp. pose a threat to both human and animal health, with more than 2600 serovars having been reported to date. Salmonella serovars are usually identified by slide agglutination tests, which are labor intensive and time consuming. In an attempt to develop a more rapid screening method for the major poultry Salmonella serovars, we developed a loop-mediated isothermal amplification (LAMP) assay, which directly detected the sefA gene, a fimbrial operon gene existing in several specific serovars of Salmonella enterica including the major poultry serovars, namely Salmonella enterica serovar Enteritidis (Salmonella Enteritidis) and Salmonella enterica serovar Gallinarum (Salmonella Gallinarum). With the 177 bacterial strains we tested, positive reactions were only observed with 85 strains of serovar Salmonella Enteritidis and Salmonella Gallinarum. The detection limit of the LAMP assay was 4 CFU/reaction with genomic DNAs of Salmonella Enteritidis (ATCC 13076) from pure culture and 400 CFU/ reaction with DNA extracted from spiked chicken feces. The LAMP assay was more sensitive than conventional culture, especially without enrichment, in detecting Salmonella Enteritidis (CMCC 50041) in the spiked fecal samples. The results show the sefA LAMP method is a rapid, sensitive, specific, and practical method for directly detection of Salmonella Enteritidis and Salmonella Gallinarum in chickens. The sefA LAMP assay can potentially serve as new on-site diagnostics in the poultry industry.

  10. A High-Throughput Enzyme Assay for Organophosphate Residues in Milk

    PubMed Central

    Mishra, Rupesh K.; Deshpande, Kanchanmala; Bhand, Sunil

    2010-01-01

    A rapid, high-sensitivity, chemiluminescence (CL) enzyme assay for the determination of organophosphate (OP) residues in milk is presented. The assay for quantification of OP residues in milk is based on the inhibition of enzyme butyrylcholinesterase (BuChE). BuChE was stabilized and preloaded in 384 well plates at 30 °C. The assay permits rapid determination of OPs in milk within 12 min including an incubation step. The enzyme assay was tested for individual and mixtures of OPs such as methyl paraoxon (MPOx), methyl parathion (MP) and malathion (MT) in milk to evaluate their synergistic effect on BuChE inhibition. Good linearity was obtained in the range 0.005–50 μg·L−1 for MPOx and 0.5–1,000 μg·L−1 for MP as well as MT in milk. Mean recovery of 93.2%–98.6% was obtained for MPOx spiked milk samples with 0.99%–1.67% reproducibility (RSD). The proposed method facilitated rapid screening of milk samples in 384 well plate formats with further miniaturization presented in 1,536 well plates. PMID:22163525

  11. Simple method for production of internal control DNA for Mycobacterium tuberculosis polymerase chain reaction assays.

    PubMed Central

    deWit, D; Wootton, M; Allan, B; Steyn, L

    1993-01-01

    A simple method for the production of internal control DNA for two well-established Mycobacterium tuberculosis polymerase chain reaction assays is described. The internal controls were produced from Mycobacterium kansasii DNA with the same primers but at a lower annealing temperature than that used in the standard assays. In both assays, therefore, the internal control DNA has the same primer-binding sequences at the target DNA. One-microgram quantities of internal control DNA which was not contaminated with target DNA could easily be produced by this method. The inclusion of the internal control in the reaction mixture did not affect the efficiency of amplification of the target DNA. The method is simple and rapid and should be adaptable to most M. tuberculosis polymerase chain reaction assays. Images PMID:8370752

  12. Rapid extraction and assay of uranium from environmental surface samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonatemore » and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.« less

  13. Surface plasmon resonance (SPR) detection of Staphylococcal Enterotoxin A in food samples

    USDA-ARS?s Scientific Manuscript database

    An automated and rapid method for detection of staphylococcal enterotoxins (SE) is needed. A sandwich assay was developed using a surface plasmon resonance (SPR) biosensor for detection of staphylococcal enterotoxin A (SEA) at subpicomolar concentration. Assay conditions were optimized for capturing...

  14. Determination of cortisol in human plasma by thin-layer chromatography and fluorescence derivatization with isonicotinic acid hydrazide.

    PubMed

    Fenske, Martin

    2008-01-01

    The present work describes a specific and rapid determination of cortisol in human plasma. The method includes liquid-liquid extraction of plasma samples, thin-layer chromatography (TLC) of ethanolic extracts on aluminium foil-backed silica gel 60 TLC plates, derivatization of cortisol with isonicotinic acid hydrazide, and densitometric measurement of the fluorescence intensity of cortisol hydrazone. The fluorescence was linearly related to cortisol amounts; the correlation coefficients of standard curve plots were r>0.99. The coefficient of variation ranged between 2.8-7.9% (20 ng, within-assay/between assay variation) and 1.6-6.8% (80 ng, within-assay/between assay variation). The recovery of cortisol from plasma spiked with 21-deoxycortisol was 85%+/-4%. Cortisol concentration in the plasma was 66+/-32 ng/mL (mean+/-standard deviation, n=24). The advantage of this method is its simplicity to separate cortisol from other steroids by TLC, its specificity (formation of cortisol hydrazone), and the rapid quantitation of cortisol by densitometry.

  15. Development of a reverse transcription loop-mediated isothermal amplification method for the rapid detection of avian influenza virus subtype H7.

    PubMed

    Bao, Hongmei; Wang, Xiurong; Zhao, Yuhui; Sun, Xiaodong; Li, Yanbing; Xiong, Yongzhong; Chen, Hualan

    2012-01-01

    A rapid and sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of the H7 avian influenza virus (H7 AIV) isotype was developed. The minimum detection limit of the RT-LAMP assay was 0.1-0.01 PFU per reaction for H7 AIV RNA, making this assay 100-fold more sensitive than the conventional RT-PCR method. This RT-LAMP assay also has the capacity to detect both high- and low-pathogenic H7 AIV strains. Using a pool of RNAs extracted from influenza viruses corresponding to all 15 HA subtypes (in addition to other avian pathogenic viruses), the RT-LAMP system was confirmed to amplify only H7 AIV RNA. Furthermore, specific pathogen free (SPF) chickens were infected artificially with H7 AIV, throat and cloacal swabs were collected, and viral shedding was examined using viral isolation, RT-PCR and RT-LAMP. Shedding was detected following viral isolation and RT-LAMP one day after infection, whereas viral detection using RT-PCR was effective only on day 3 post-infection. These results indicate that the RT-LAMP method could facilitate epidemiological surveillance and the rapid diagnosis of the avian influenza subtype H7. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Current use and acceptability of novel diagnostic tests for active tuberculosis: a worldwide survey

    PubMed Central

    Amicosante, Massimo; D’Ambrosio, Lia; Munoz, Marcela; Mello, Fernanda Carvalho de Queiroz; Tebruegge, Marc; Chegou, Novel Njweipi; Seghrouchni, Fouad; Centis, Rosella; Goletti, Delia; Bothamley, Graham; Migliori, Giovanni Battista

    2017-01-01

    ABSTRACT Objective: To determine the current use and potential acceptance (by tuberculosis experts worldwide) of novel rapid tests for the diagnosis of tuberculosis that are in line with World Health Organization target product profiles. Methods: A multilingual survey was disseminated online between July and November of 2016. Results: A total of 723 individuals from 114 countries responded to the survey. Smear microscopy was the most commonly used rapid tuberculosis test (available to 90.9% of the respondents), followed by molecular assays (available to 70.7%). Only a small proportion of the respondents in middle- and low-income countries had access to interferon-gamma-release assays. Serological and lateral flow immunoassays were used by more than a quarter (25.4%) of the respondents. Among the respondents who had access to molecular tests, 46.7% were using the Xpert assay overall, that proportion being higher in lower middle-income countries (55.6%) and low-income countries (76.6%). The data also suggest that there was some alignment of pricing for molecular assays. Respondents stated they would accept novel rapid tuberculosis tests if available, including molecular assays (acceptable to 86.0%) or biomarker-based serological assays (acceptable to 81.7%). Simple biomarker-based assays were more commonly deemed acceptable in middle- and low-income countries. Conclusions: Second-generation molecular assays have become more widely available in high- and low-resource settings. However, the development of novel rapid tuberculosis tests continues to be considered important by tuberculosis experts. Our data also underscore the need for additional training and education of end users. PMID:29160384

  17. Comparison of real-time SYBR green dengue assay with real-time taqman RT-PCR dengue assay and the conventional nested PCR for diagnosis of primary and secondary dengue infection

    PubMed Central

    Paudel, Damodar; Jarman, Richard; Limkittikul, Kriengsak; Klungthong, Chonticha; Chamnanchanunt, Supat; Nisalak, Ananda; Gibbons, Robert; Chokejindachai, Watcharee

    2011-01-01

    Background: Dengue fever and dengue hemorrhagic fever are caused by dengue virus. Dengue infection remains a burning problem of many countries. To diagnose acute dengue in the early phase we improve the low cost, rapid SYBR green real time assay and compared the sensitivity and specificity with real time Taqman® assay and conventional nested PCR assay. Aims: To develop low cost, rapid and reliable real time SYBR green diagnostic dengue assay and compare with Taqman real-time assay and conventional nested PCR (modified Lanciotti). Materials and Methods: Eight cultured virus strains were diluted in tenth dilution down to undetectable level by the PCR to optimize the primer, temperature (annealing, and extension and to detect the limit of detection of the assay. Hundred and ninety three ELISA and PCR proved dengue clinical samples were tested with real time SYBR® Green assay, real time Taqman® assay to compare the sensitivity and specificity. Results: Sensitivity and specificity of real time SYBR® green dengue assay (84% and 66%, respectively) was almost comparable to those (81% and 74%) of Taqman real time PCR dengue assay. Real time SYBR® green RT-PCR was equally sensitive in primary and secondary infection while real time Taqman was less sensitive in the secondary infection. Sensitivity of real time Taqman on DENV3 (87%) was equal to SYBR green real time PCR dengue assay. Conclusion: We developed low cost rapid diagnostic SYBR green dengue assay. Further study is needed to make duplex primer assay for the serotyping of dengue virus. PMID:22363089

  18. STANDARDIZATION OF A FLUORESCENT-BASED QUANTITATIVE ADHESION ASSAY TO STUDY ATTACHMENT OF Taenia solium ONCOSPHERE TO EPITHELIAL CELLS In Vitro

    PubMed Central

    Chile, Nancy; Evangelista, Julio; Gilman, Robert H.; Arana, Yanina; Palma, Sandra; Sterling, Charles R; Garcia, Hector H.; Gonzalez, Armando; Verastegui, Manuela

    2012-01-01

    To fully understand the preliminary stages of Taenia solium oncosphere attachment in the gut, adequate tools and assays are necessary to observe and quantify this event that leads to infection. A fluorescent-based quantitative adhesion assay, using biotinylated activated-oncospheres and monolayers of Chinese hamster ovary cells (CHO-K1) or human intestinal monolayer cells (INT-407, HCT-8 or HT-29), was developed to study initial events during the infection of target cells and to rapidly quantify the in vitro adhesion of T. solium oncospheres. Fluorescein streptavidin was used to identify biotinylated activated-oncospheres adhered to cells. This adherence was quantified using an automated fluorescence plate reader, and the results were expressed as fluorescence intensity values. A series of three assays were performed. The first was to identify the optimum number of biotinylated activated-oncospheres to be used in the adhesion assay. The goal of the second assay was to validate this novel method with the established oncosphere-binding system using the immunofluorescent-antibody assay (IFA) method to quantify oncosphere adhesion. A total of 10,000 biotinylated activated-oncospheres were utilized to assess the role of sera and laminin (LM) in oncosphere adherence to a CHO-K1 cell monolayer. The findings that sera and LM increase the adhesion of oncospheres to monolayer cells were similar to results that were previously obtained using the IFA method. The third assay compared the adherence of biotinylated activated-oncospheres to different types of human intestinal monolayer cells. In this case, the fluorescence intensity was greatest when using the INT-407 cell monolayer. We believe this new method of quantification offers the potential for rapid, large-scale screening to study and elucidate specific molecules and mechanisms involved in oncosphere-host cell attachment. PMID:22178422

  19. Multicenter Evaluation of the Solana Group A Streptococcus Assay: Comparison with Culture.

    PubMed

    Uphoff, Timothy S; Buchan, Blake W; Ledeboer, Nathan A; Granato, Paul A; Daly, Judy A; Marti, Tara N

    2016-09-01

    We compared group A Streptococcus (GAS) culture with a rapid helicase-dependent amplification (HDA) method using 1,082 throat swab specimens. The HDA method demonstrated 98.2% sensitivity and 97.2% specificity. GAS prevalence by culture was 20.7%, and it was 22.6% using the HDA method. In 35 min, the HDA method provided rapid, sensitive GAS detection, making culture confirmation unnecessary. Copyright © 2016 Uphoff et al.

  20. Comparison of methods for the detection of coliphages in recreational water at two California, United States beaches.

    PubMed

    Rodríguez, Roberto A; Love, David C; Stewart, Jill R; Tajuba, Julianne; Knee, Jacqueline; Dickerson, Jerold W; Webster, Laura F; Sobsey, Mark D

    2012-04-01

    Methods for detection of two fecal indicator viruses, F+ and somatic coliphages, were evaluated for application to recreational marine water. Marine water samples were collected during the summer of 2007 in Southern California, United States from transects along Avalon Beach (n=186 samples) and Doheny Beach (n=101 samples). Coliphage detection methods included EPA method 1601 - two-step enrichment (ENR), EPA method 1602 - single agar layer (SAL), and variations of ENR. Variations included comparison of two incubation times (overnight and 5-h incubation) and two final detection steps (lysis zone assay and a rapid latex agglutination assay). A greater number of samples were positive for somatic and F+ coliphages by ENR than by SAL (p<0.01). The standard ENR with overnight incubation and detection by lysis zone assay was the most sensitive method for the detection of F+ and somatic coliphages from marine water, although the method takes up to three days to obtain results. A rapid 5-h enrichment version of ENR also performed well, with more positive samples than SAL, and could be performed in roughly 24h. Latex agglutination-based detection methods require the least amount of time to perform, although the sensitivity was less than lysis zone-based detection methods. Rapid culture-based enrichment of coliphages in marine water may be possible by further optimizing culture-based methods for saline water conditions to generate higher viral titers than currently available, as well as increasing the sensitivity of latex agglutination detection methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid Detection of Cannabis sativa.

    PubMed

    Kitamura, Masashi; Aragane, Masako; Nakamura, Kou; Watanabe, Kazuhito; Sasaki, Yohei

    2016-07-01

    In many parts of the world, the possession and cultivation of Cannabis sativa L. are restricted by law. As chemical or morphological analyses cannot identify the plant in some cases, a simple yet accurate DNA-based method for identifying C. sativa is desired. We have developed a loop-mediated isothermal amplification (LAMP) assay for the rapid identification of C. sativa. By optimizing the conditions for the LAMP reaction that targets a highly conserved region of tetrahydrocannabinolic acid (THCA) synthase gene, C. sativa was identified within 50 min at 60-66°C. The detection limit was the same as or higher than that of conventional PCR. The LAMP assay detected all 21 specimens of C. sativa, showing high specificity. Using a simple protocol, the identification of C. sativa could be accomplished within 90 min from sample treatment to detection without use of special equipment. A rapid, sensitive, highly specific, and convenient method for detecting and identifying C. sativa has been developed and is applicable to forensic investigations and industrial quality control.

  2. Direct detection of Leishmania from clinical samples.

    PubMed

    Waitumbi, John N; Bast, Joshua; Nyakoe, Nancy; Magiri, Charles; Quintana, Miguel; Takhampunya, Ratree; Schuster, Anthony L; Van de Wyngaerde, Marshall T; McAvin, James C; Coleman, Russell E

    2017-01-01

    The ability to rapidly and accurately diagnose leishmaniasis is a military priority. Testing was conducted to evaluate diagnostic sensitivity and specificity of field-expedient Leishmania genus and visceral Leishmania specific dual-fluorogenic, hydrolysis probe (TaqMan), polymerase chain reaction assays previously established for use in vector surveillance. Blood samples of patients with confirmed visceral leishmaniasis and controls without the disease from Baringo District, Kenya, were tested. Leishmania genus assay sensitivity was 100% (14/14) and specificity was 84% (16/19). Visceral Leishmania assay sensitivity was 93% (13/14) and specificity 80% (4/5). Cutaneous leishmaniasis (CL) skin scrapes of patients from Honduras were also evaluated. Leishmania genus assay sensitivity was 100% (10/10). Visceral Leishmania assay specificity was 100% (10/10) from cutaneous leishmaniasis samples; no fluorescence above background was reported. These results show promise in a rapid, sensitive, and specific method for Leishmania direct detection from clinical samples.

  3. Shape-coded silica nanotubes for multiplexed bioassay: rapid and reliable magnetic decoding protocols

    PubMed Central

    He, Bo; Kim, Sung Kyoung; Son, Sang Jun; Lee, Sang Bok

    2010-01-01

    Aims The recent development of 1D barcode arrays has proved their capabilities to be applicable to highly multiplexed bioassays. This article introduces two magnetic decoding protocols for suspension arrays of shape-coded silica nanotubes to process multiplexed assays rapidly and easily, which will benefit the minimization and automation of the arrays. Methods In the first protocol, the magnetic nanocrystals are incorporated into the inner voids of barcoded silica nanotubes in order to give the nanotubes magnetic properties. The second protocol is performed by trapping the barcoded silica nanotubes onto streptavidin-modified magnetic beads. Results The rapid and easy decoding process was demonstrated by applying the above two protocols to multiplexed assays, resulting in high selectivity. Furthermore, the magnetic bead-trapped barcode nanotubes provided a great opportunity to exclude the use of dye molecules in multiplexed assays by using barcode nanotubes as signals. Conclusion The rapid and easy manipulation of encoded carriers using magnetic properties could be used to develop promising suspension arrays for portable bioassays. PMID:20025466

  4. Study and evaluation of Wondfo rapid diagnostic kit based on nano-gold immunochromatography assay for diagnosis of Plasmodium falciparum.

    PubMed

    Peng, Yunping; Wu, Junlin; Wang, Jihua; Li, Wenmei; Yu, Shujuan

    2012-04-01

    Malaria has been recognized as a human disease for thousands of years and remains one of the most common diseases affecting humans worldwide. Therefore, a method for rapidly detecting Plasmodium falciparum is necessary and useful. We have developed Wondfo rapid diagnostic kit based on nano-gold immunochromatography assay for the detection of P. falciparum in patient specimen. In the present study, we demonstrated the sensitivity and specificity of the rapid diagnostic kit in which nano-gold labeling techniques and the monoclonal antibodies against histidine-rich protein-2 of P. falciparum were used to establish two-antibody sandwich immunochromatographic assay for detecting P. falciparum. By using microscopic examination of blood smears as control, the sensitivity, specificity, and feasibility of Wondfo rapid diagnostic kit was determined in the prompt and accurate diagnosis of malaria. In this study, 1,558 blood samples were collected from outpatient clinics in China and detected by both Wondfo kit and microscopic examination. The Wondfo kit did not show cross-reaction with microfilaria, Toxoplasma gondii, and other parasites in the blood. The patient samples positive for rheumatoid factor, HIV, tuberculosis, and syphilis did not show false positivity when testing with Wondfo kit. The detection sensitivity and specificity of Wondfo rapid diagnostic kit were 95.49% and 99.53%, respectively. These results indicate that our rapid diagnostic assay may be useful for detecting P. falciparum in patient specimen.

  5. New LightCycler PCR for Rapid and Sensitive Quantification of Parvovirus B19 DNA Guides Therapeutic Decision-Making in Relapsing Infections

    PubMed Central

    Harder, Timm C.; Hufnagel, Markus; Zahn, Katrin; Beutel, Karin; Schmitt, Heinz-Josef; Ullmann, Uwe; Rautenberg, Peter

    2001-01-01

    Detection of parvovirus B19 DNA offers diagnostic advantages over serology, particularly in persistent infections of immunocompromised patients. A rapid, novel method of B19 DNA detection and quantification is introduced. This method, a quantitative PCR assay, is based on real-time glass capillary thermocycling (LightCycler [LC]) and fluorescence resonance energy transfer (FRET). The PCR assay allowed quantification over a dynamic range of over 7 logs and could quantify as little as 250 B19 genome equivalents (geq) per ml as calculated for plasmid DNA (i.e., theoretically ≥5 geq per assay). Interrater agreement analysis demonstrated equivalence of LC-FRET PCR and conventional nested PCR in the diagnosis of an active B19 infection (kappa coefficient = 0.83). The benefit of the new method was demonstrated in an immunocompromised child with a relapsing infection, who required an attenuation of the immunosuppressive therapy in addition to repeated doses of immunoglobulin to eliminate the virus. PMID:11724854

  6. Development and Validation of a Rapid 13C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices

    PubMed Central

    Matsunami, Risë K.; Angelides, Kimon; Engler, David A.

    2015-01-01

    Background: There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. Methods: An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using 13C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and 13C6-glucose. Results: The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. Conclusions: The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. PMID:25986627

  7. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    PubMed Central

    2009-01-01

    Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9) and 97.7% (95% CI; 95.7–98.9), respectively, which increased to 100% (95% CI; 99.1–100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100) while specificities were 99.6% (95% CI; 99–99.9), 99.4% (95% CI; 98.8–99.7), 99.6% (95% CI; 99–99.9) and 99.8% (95% CI; 99.3–99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. Conclusion An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1–100) and 100% specificity (95% CI; 96–99.1) with Uni-Gold™ as tiebreaker for discordant results. PMID:19226452

  8. Development of a rapid, robust, and universal picogreen-based method to titer adeno-associated vectors.

    PubMed

    Piedra, Jose; Ontiveros, Maria; Miravet, Susana; Penalva, Cristina; Monfar, Mercè; Chillon, Miguel

    2015-02-01

    Recombinant adeno-associated viruses (rAAVs) are promising vectors in preclinical and clinical assays for the treatment of diseases with gene therapy strategies. Recent technological advances in amplification and purification have allowed the production of highly purified rAAV vector preparations. Although quantitative polymerase chain reaction (qPCR) is the current method of choice for titrating rAAV genomes, it shows high variability. In this work, we report a rapid and robust rAAV titration method based on the quantitation of encapsidated DNA with the fluorescent dye PicoGreen®. This method allows detection from 3×10(10) viral genome/ml up to 2.4×10(13) viral genome/ml in a linear range. Contrasted with dot blot or qPCR, the PicoGreen-based assay has less intra- and interassay variability. Moreover, quantitation is rapid, does not require specific primers or probes, and is independent of the rAAV pseudotype analyzed. In summary, development of this universal rAAV-titering method may have substantive implications in rAAV technology.

  9. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    PubMed

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  10. Rapid colorimetric assay for gentamicin injection.

    PubMed

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  11. Specific detection of Pectobacterium carotovorum by loop-mediated isothermal amplification.

    PubMed

    Yasuhara-Bell, Jarred; Marrero, Glorimar; De Silva, Asoka; Alvarez, Anne M

    2016-12-01

    Potatoes are an important agroeconomic crop worldwide and maceration diseases caused by pectolytic bacterial pathogens result in significant pre- and post-harvest losses. Pectobacterium carotovorum shares a common host range with other Pectobacterium spp. and other members of the Enterobacteriaceae, such as Dickeya spp. As these pathogens cannot be clearly differentiated on the basis of the symptoms they cause, improved methods of identification are critical for the determination of sources of contamination. Current standardized methods for the differentiation of pectolytic species are time consuming and require trained personnel, as they rely on traditional bacteriological practices that do not always produce conclusive results. In this growing world market, there is a need for rapid diagnostic tests that can differentiate between pectolytic pathogens, as well as separate them from non-pectolytic enteric bacteria associated with soft rots of potato. An assay has been designed previously to detect the temperate pathogen Pectobacterium atrosepticum, but there is currently no recognized rapid assay for the detection of the tropical/subtropical counterpart, Pectobacterium carotovorum. This report describes the development of a loop-mediated isothermal amplification (LAMP) assay that detects P. carotovorum with high specificity. The assay was evaluated using all known species of Pectobacterium and only showed positive reactions for P. carotovorum. This assay was also tested against 15 non-target genera of plant-associated bacteria and did not produce any false positives. The LAMP assay described here can be used as a rapid test for the differentiation of P. carotovorum from other pectolytic pathogens, and its gene target can be the basis for the development of other molecular-based detection assays. © 2016 BSPP and John Wiley & Sons Ltd.

  12. Development and Application of Loop-Mediated Isothermal Amplification Assays for Rapid Visual Detection of cry2Ab and cry3A Genes in Genetically-Modified Crops

    PubMed Central

    Li, Feiwu; Yan, Wei; Long, Likun; Qi, Xing; Li, Congcong; Zhang, Shihong

    2014-01-01

    The cry2Ab and cry3A genes are two of the most important insect-resistant exogenous genes and had been widely used in genetically-modified crops. To develop more effective alternatives for the quick identification of genetically-modified organisms (GMOs) containing these genes, a rapid and visual loop-mediated isothermal amplification (LAMP) method to detect the cry2Ab and cry3A genes is described in this study. The LAMP assay can be finished within 60 min at an isothermal condition of 63 °C. The derived LAMP products can be obtained by a real-time turbidimeter via monitoring the white turbidity or directly observed by the naked eye through adding SYBR Green I dye. The specificity of the LAMP assay was determined by analyzing thirteen insect-resistant genetically-modified (GM) crop events with different Bt genes. Furthermore, the sensitivity of the LAMP assay was evaluated by diluting the template genomic DNA. Results showed that the limit of detection of the established LAMP assays was approximately five copies of haploid genomic DNA, about five-fold greater than that of conventional PCR assays. All of the results indicated that this established rapid and visual LAMP assay was quick, accurate and cost effective, with high specificity and sensitivity. In addition, this method does not need specific expensive instruments or facilities, which can provide a simpler and quicker approach to detecting the cry2Ab and cry3A genes in GM crops, especially for on-site, large-scale test purposes in the field. PMID:25167136

  13. Development and application of loop-mediated isothermal amplification assays for rapid visual detection of cry2Ab and cry3A genes in genetically-modified crops.

    PubMed

    Li, Feiwu; Yan, Wei; Long, Likun; Qi, Xing; Li, Congcong; Zhang, Shihong

    2014-08-27

    The cry2Ab and cry3A genes are two of the most important insect-resistant exogenous genes and had been widely used in genetically-modified crops. To develop more effective alternatives for the quick identification of genetically-modified organisms (GMOs) containing these genes, a rapid and visual loop-mediated isothermal amplification (LAMP) method to detect the cry2Ab and cry3A genes is described in this study. The LAMP assay can be finished within 60 min at an isothermal condition of 63 °C. The derived LAMP products can be obtained by a real-time turbidimeter via monitoring the white turbidity or directly observed by the naked eye through adding SYBR Green I dye. The specificity of the LAMP assay was determined by analyzing thirteen insect-resistant genetically-modified (GM) crop events with different Bt genes. Furthermore, the sensitivity of the LAMP assay was evaluated by diluting the template genomic DNA. Results showed that the limit of detection of the established LAMP assays was approximately five copies of haploid genomic DNA, about five-fold greater than that of conventional PCR assays. All of the results indicated that this established rapid and visual LAMP assay was quick, accurate and cost effective, with high specificity and sensitivity. In addition, this method does not need specific expensive instruments or facilities, which can provide a simpler and quicker approach to detecting the cry2Ab and cry3A genes in GM crops, especially for on-site, large-scale test purposes in the field.

  14. A multiplex PCR for detection of Listeria monocytogenes and its lineages.

    PubMed

    Rawool, Deepak B; Doijad, Swapnil P; Poharkar, Krupali V; Negi, Mamta; Kale, Satyajit B; Malik, S V S; Kurkure, Nitin V; Chakraborty, Trinad; Barbuddhe, Sukhadeo B

    2016-11-01

    A novel multiplex PCR assay was developed to identify genus Listeria, and discriminate Listeria monocytogenes and its major lineages (LI, LII, LIII). This assay is a rapid and inexpensive subtyping method for screening and characterization of L. monocytogenes. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Evaluating the Impact of Uncertainties in Clearance and Exposure When Prioritizing Chemicals Screened in High-Throughput Assays

    EPA Science Inventory

    The toxicity-testing paradigm has evolved to include high-throughput (HT) methods for addressing the increasing need to screen hundreds to thousands of chemicals rapidly. Approaches that involve in vitro screening assays, in silico predictions of exposure concentrations, and phar...

  16. Sensitivity of neuroprogenitor cells to chemical-induced apoptosis using a multiplexed assay suitable for high-throughput screening*

    EPA Science Inventory

    AbstractHigh-throughput methods are useful for rapidly screening large numbers of chemicals for biological activity, including the perturbation of pathways that may lead to adverse cellular effects. In vitro assays for the key events of neurodevelopment, including apoptosis, may ...

  17. Development and evaluation of probe based real time loop mediated isothermal amplification for Salmonella: A new tool for DNA quantification.

    PubMed

    Mashooq, Mohmad; Kumar, Deepak; Niranjan, Ankush Kiran; Agarwal, Rajesh Kumar; Rathore, Rajesh

    2016-07-01

    A one step, single tube, accelerated probe based real time loop mediated isothermal amplification (RT LAMP) assay was developed for detecting the invasion gene (InvA) of Salmonella. The probe based RT LAMP is a novel method of gene amplification that amplifies nucleic acid with high specificity and rapidity under isothermal conditions with a set of six primers. The whole procedure is very simple and rapid, and amplification can be obtained in 20min. Detection of gene amplification was accomplished by amplification curve, turbidity and addition of DNA binding dye at the end of the reaction results in colour difference and can be visualized under normal day light and in UV. The sensitivity of developed assay was found 10 fold higher than taqman based qPCR. The specificity of the RT LAMP assay was validated by the absence of any cross reaction with other members of enterobacteriaceae family and other gram negative bacteria. These results indicate that the probe based RT LAMP assay is extremely rapid, cost effective, highly specific and sensitivity and has potential usefulness for rapid Salmonella surveillance. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  18. Rapid and Sensitive Detection of Lymphocystis Disease Virus Genotype VII by Loop-Mediated Isothermal Amplification.

    PubMed

    Valverde, Estefanía J; Cano, Irene; Castro, Dolores; Paley, Richard K; Borrego, Juan J

    2017-03-01

    Lymphocystis disease virus (LCDV) infections have been described in gilthead seabream (Sparus aurata L.) and Senegalese sole (Solea senegalensis, Kaup), two of the most important marine fish species in the Mediterranean aquaculture. In this study, a rapid, specific, and sensitive detection method for LCDV genotype VII based on loop-mediated isothermal amplification (LAMP) was developed. The LAMP assay, performed using an apparatus with real-time amplification monitoring, was able to specifically detect LCDV genotype VII from clinically positive samples in less than 12 min. In addition, the assay allowed the detection of LCDV in all asymptomatic carrier fish analysed, identified by qPCR, showing an analytical sensitivity of ten copies of viral DNA per reaction. The LCDV LAMP assay has proven to be a promising diagnostic method that can be used easily in fish farms to detect the presence and spread of this iridovirus.

  19. A rapid microtiter plate serum bactericidal assay method for determining serum complement-mediated killing of Mannheimia haemolytica.

    PubMed

    Ayalew, Sahlu; Confer, Anthony W; Shrestha, Binu; Payton, Mark E

    2012-05-01

    In this study, we describe a rapid microtiter serum bactericidal assay (RMSBA) that can be used to measure the functionality of immune sera. It quantifies bactericidal activity of immune sera in the presence of complement against a homologous bacterium, M. haemolytica in this case. There is high correlation between data from RMSBA and standard complement-mediated bacterial killing assay (r=0.756; p<0.0001). The RMSBA activity of sera can be generated in less than 5 h instead of overnight incubation. RMSBA costs substantially less in terms of time, labor, and resources and is highly reproducible. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Rapid isothermal detection of Phytophthora species on plant samples using recombinase polymerase amplification

    USDA-ARS?s Scientific Manuscript database

    Recently several isothermal amplification techniques have been developed that are extremely tolerant towards inhibitors present in many plant extracts. Recombinase polymerase amplification (RPA) assays for the genus Phytophthora have been developed which provide a simple and rapid method to macerate...

  1. A simple and rapid radiochemical choline acetyltransferase (ChAT) assay screening test.

    PubMed

    Shiba, Kazuhiro; Ogawa, Kazuma; Kinuya, Seigo; Yajima, Kazuyoshi; Mori, Hirofumi

    2006-10-15

    A simple radiochemical choline acetyltransferase (ChAT) assay screening test was developed by measuring for [(3)H]acetylcholine ([(3)H]ACh) formed from 0.2 mM [(3)H]acetyl-coenzyme A ([(3)H]acetyl-CoA) and 1 mM choline by 0.2 mg of rat brain homogenates containing ChAT into 96-well microplates. A simple and rapid procedure for isolating [(3)H]ACh from the incubation mixture into 96-well microplates was achieved by using a sodium tetraphenylboron (Kalibor) solution (in ethyl acetate, 0.75%, w/v) and a hydrophobic liquid scintillator mixture (1:5, v/v, 0.2 mL) as an extraction solvent. The benefits of this radiochemical method using 96-well microplates are as follows: (1) this method is reliable and reproducible; (2) many samples can be examined at the same time by this method; (3) this method is economical and effective in reducing radioactive waste. The development of a new simple radiochemical ChAT assay screening test is the first stage of development of radiolabeled ChAT mapping agent.

  2. Laboratory diagnosis of Chlamydia pneumoniae infections

    PubMed Central

    Peeling, Rosanna W

    1995-01-01

    Chlamydia pneumoniae is an important cause of respiratory illness. There is a need for accurate and rapid laboratory diagnostic methods that will lead to improved patient care, appropriate use of antimicrobial therapy and a better understanding of the epidemiology of this emerging pathogen. Culture is highly specific but is technically demanding, expensive, has a long turnaround time and its sensitivity is highly dependent on transport conditions. Antigen detection tests such as enzyme immunoassay and direct fluorescent antibody assay, and molecular detection methods such as the polymerase chain reaction assay, may provide a rapid diagnosis without the requirement for stringent transport conditions. The results of these tests should be interpreted with caution until more thorough evaluation is available. Serology remains the method of choice. The limitations of different serological methods for the laboratory diagnosis of C pneumoniae are discussed. PMID:22514397

  3. [Methods of testing inactivated antirabies vaccines].

    PubMed

    Nedosekov, V V; Vishniakov, I F; Gruzdev, K N

    2001-01-01

    Methods for evaluating the potency of inactivated rabies vaccines are reviewed. Shortcomings of the traditional NIH method and advantages of modern rapid immunological in vitro methods (antibody binding test, radial immunodiffusion test, enzyme linked immunoadsorbent assay) for estimation of antigenic activity of vaccines are discussed.

  4. Interdigitated microelectrode based impedance biosensor for detection of salmonella enteritidis in food samples

    NASA Astrophysics Data System (ADS)

    Kim, G.; Morgan, M.; Hahm, B. K.; Bhunia, A.; Mun, J. H.; Om, A. S.

    2008-03-01

    Salmonella enteritidis outbreaks continue to occur, and S. enteritidis-related outbreaks from various food sources have increased public awareness of this pathogen. Conventional methods for pathogens detection and identification are labor-intensive and take days to complete. Some immunological rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown great potential for the rapid detection of foodborne pathogens. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on avidin-biotin binding on the surface of the IME to form an active sensing layer. To increase the sensitivity of the sensor, three types of sensors that have different electrode gap sizes (2 μm, 5 μm, 10 μm) were fabricated and tested. The impedimetric biosensor could detect 103 CFU/mL of Salmonella in pork meat extract with an incubation time of 5 minutes. This method may provide a simple, rapid and sensitive method to detect foodborne pathogens.

  5. Emerging metrology for high-throughput nanomaterial genotoxicology.

    PubMed

    Nelson, Bryant C; Wright, Christa W; Ibuki, Yuko; Moreno-Villanueva, Maria; Karlsson, Hanna L; Hendriks, Giel; Sims, Christopher M; Singh, Neenu; Doak, Shareen H

    2017-01-01

    The rapid development of the engineered nanomaterial (ENM) manufacturing industry has accelerated the incorporation of ENMs into a wide variety of consumer products across the globe. Unintentionally or not, some of these ENMs may be introduced into the environment or come into contact with humans or other organisms resulting in unexpected biological effects. It is thus prudent to have rapid and robust analytical metrology in place that can be used to critically assess and/or predict the cytotoxicity, as well as the potential genotoxicity of these ENMs. Many of the traditional genotoxicity test methods [e.g. unscheduled DNA synthesis assay, bacterial reverse mutation (Ames) test, etc.,] for determining the DNA damaging potential of chemical and biological compounds are not suitable for the evaluation of ENMs, due to a variety of methodological issues ranging from potential assay interferences to problems centered on low sample throughput. Recently, a number of sensitive, high-throughput genotoxicity assays/platforms (CometChip assay, flow cytometry/micronucleus assay, flow cytometry/γ-H2AX assay, automated 'Fluorimetric Detection of Alkaline DNA Unwinding' (FADU) assay, ToxTracker reporter assay) have been developed, based on substantial modifications and enhancements of traditional genotoxicity assays. These new assays have been used for the rapid measurement of DNA damage (strand breaks), chromosomal damage (micronuclei) and for detecting upregulated DNA damage signalling pathways resulting from ENM exposures. In this critical review, we describe and discuss the fundamental measurement principles and measurement endpoints of these new assays, as well as the modes of operation, analytical metrics and potential interferences, as applicable to ENM exposures. An unbiased discussion of the major technical advantages and limitations of each assay for evaluating and predicting the genotoxic potential of ENMs is also provided. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society 2016.

  6. Development and application of loop-mediated isothermal amplification (LAMP) for detection of Plasmopara viticola

    PubMed Central

    Kong, Xiangjiu; Qin, Wentao; Huang, Xiaoqing; Kong, Fanfang; Schoen, Cor D.; Feng, Jie; Wang, Zhongyue; Zhang, Hao

    2016-01-01

    A rapid LAMP (loop-mediated isothermal amplification) detection method was developed on the basis of the ITS sequence of P. viticola, the major causal agent of grape downy mildew. Among the 38 fungal and oomycete species tested, DNA isolated exclusively from P. viticola resulted in a specific product after LAMP amplification. This assay had high sensitivity and was able to detect the presence of less than 33 fg of genomic DNA per 25-μL reaction within 30 min. The infected leaves may produce sporangia that serve as a secondary inoculum. The developed LAMP assay is efficient for estimating the latent infection of grape leaves by P. viticola. When combined with the rapid and simple DNA extraction method, this assay’s total detection time is shortened to approximately one hour; therefore it is suitable for on-site detection of latent infection in the field. The sporangia levels in the air are strongly associated with disease severity. The LAMP method was also demonstrated to be able to estimate the level of sporangia released in the air in a certain period. This assay should make disease forecasting more accurate and rapid and should be helpful in decision-making regarding the control of grape downy mildew. PMID:27363943

  7. One-tube loop-mediated isothermal amplification combined with restriction endonuclease digestion and ELISA for colorimetric detection of resistance to isoniazid, ethambutol and streptomycin in Mycobacterium tuberculosis isolates.

    PubMed

    Lee, Mei-Feng; Chen, Yen-Hsu; Hsu, Hui-Jine; Peng, Chien-Fang

    2010-10-01

    In this study, we designed a simple and rapid colorimetric detection method, a one-tube loop-mediated isothermal amplification (LAMP)-PCR-hybridization-restriction endonuclease-ELISA [one-tube LAMP-PCR-HY-RE-ELISA] system, to detect resistance to isoniazid, ethambutol and streptomycin in strains of Mycobacterium tuberculosis isolated from clinical specimens. The clinical performance of this method for detecting isoniazid-resistant, ethambutol-resistant and streptomycin-resistant isolates of M. tuberculosis showed 98.9%, 94.3% and 93.8%, respectively. This assay is rapid and convenient that can be performed within one working day. One-tube LAMP-PCR-HY-RE-ELISA system was designed based on hot spot point mutations in target drug-resistant genes, using LAMP-PCR, hybridization, digestion with restriction endonuclease and colorimetric method of ELISA. In this study, LAMP assay was used to amplify DNA from drug-resistant M. tuberculosis, and ELISA was used for colorimetrical determination. This assay will be a useful tool for rapid diagnosis of mutant codons in strains of M. tuberculosis for isoniazid at katG 315 and katG 463, ethambutol at embB 306 and embB 497, and streptomycin at rpsL 43. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  8. Immunoliposome-based immunomagnetic concentration and separation assay for rapid detection of Cronobacter sakazakii.

    PubMed

    Shukla, Shruti; Lee, Gibaek; Song, Xinjie; Park, Sunhyun; Kim, Myunghee

    2016-03-15

    This study aimed to develop an immunoliposome-based immunomagnetic concentration and separation assay for the rapid detection of Cronobacter sakazakii (C. sakazakii), an acute opportunistic foodborne pathogenic bacterium, in both pure culture and infant formula. To develop the assay, magnetic nanoparticles (diameter 30 nm) were coated with immunoglobulin G (IgG), specifically anti-C. sakazakii IgG, and applied for the sensitive and efficient detection of C. sakazakii using immunoliposomes. The binding efficiency of anti-C. sakazakii IgG to the magnetic nanoparticles was 86.23 ± 0.59%. The assay developed in this study detected as few as 3.3 × 10(3) CFUmL(-1) of C. sakazakii in pure culture within 2h 30 min; in comparison, an indirect non-competitive enzyme-linked immunosorbent assay was able to detect 6.2 × 10(5) CFUmL(-1) of C. sakazakii in pure culture after 17 h. The developed assay did not show any cross-reactivity with other Cronobacter spp. or pathogens belonging to other genera. In addition, the method was able to detect 10(3) CFUmL(-1) of C. sakazakii in infant formula without any pre-incubation. These results confirm that the immunoliposome-based immunomagnetic concentration and separation assay may facilitate highly sensitive, efficient, and rapid detection of C. sakazakii. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Utility of a stressed-SNP real-time PCR assay for the rapid identification of measles vaccine strain in patient samples.

    PubMed

    Tran, Thomas; Kostecki, Renata; Catton, Michael; Druce, Julian

    2018-05-09

    Rapid differentiation of wild-type measles virus from measles vaccine strains is crucial during a measles outbreak and in a measles elimination setting. A real-time RT-PCR for the rapid detection of measles vaccine strains was developed with high specificity and greater sensitivity than when compared to traditional measles genotyping methods. The "stressed" minor grove binder TaqMan probe design approach achieves specificity to vaccine strains only, without compromising sensitivity. This assay has proven to be extremely useful in outbreak settings, without requiring sequence genotyping, for over 4 years at the Regional Measles Reference Laboratory for the Western Pacific Region. Copyright © 2018 Tran et al.

  10. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    PubMed

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  11. Development and Evaluation of an Enzyme-Linked Immunosorbent Assay To Detect Histoplasma capsulatum Antigenuria in Immunocompromised Patients▿

    PubMed Central

    Scheel, Christina M.; Samayoa, Blanca; Herrera, Alejandro; Lindsley, Mark D.; Benjamin, Lynette; Reed, Yvonne; Hart, John; Lima, Sandra; Rivera, Blanca E.; Raxcaco, Gabriella; Chiller, Tom; Arathoon, Eduardo; Gómez, Beatriz L.

    2009-01-01

    Histoplasma capsulatum infection causes significant morbidity and mortality in human immunodeficiency virus-infected individuals, particularly those in countries with limited access to rapid diagnostics or antiretroviral therapies. The fungus easily disseminates in persons with AIDS, resulting in progressive disseminated histoplasmosis (PDH), which can progress rapidly to death if undiagnosed. The availability of a simple, rapid method to detect H. capsulatum infection in less developed countries where the infection is endemic would dramatically decrease the time to diagnosis and treatment of PDH. We have developed an antigen-capture enzyme-linked immunosorbent assay (ELISA) to detect PDH antigenuria in infected patients. The assay uses polyclonal antibodies against H. capsulatum as both capture and detection reagents, and a standard reference curve is included to quantify antigenuria and ensure reproducibility. We evaluated this assay using specimens collected from patients with AIDS and culture-proven histoplasmosis in a Guatemalan clinic (n = 48), from healthy persons (n = 83), and from patients with other, nonhistoplasmosis diseases (n = 114). The ELISA demonstrated a sensitivity of 81% and a specificity of 95% in detecting H. capsulatum antigen in urine. This assay relies on simple technology that can be performed in institutions with limited resources. Use of this test will facilitate rapid diagnosis of PDH in countries where mortality is high, expediting treatment and likely reducing PDH-related mortality. PMID:19357311

  12. Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices.

    PubMed

    Matsunami, Risë K; Angelides, Kimon; Engler, David A

    2015-05-18

    There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using (13)C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and (13)C6-glucose. The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. © 2015 Diabetes Technology Society.

  13. Development of Rapid Isothermal Amplification Assays for Detection of Phytophthora spp. in Plant Tissue.

    PubMed

    Miles, Timothy D; Martin, Frank N; Coffey, Michael D

    2015-02-01

    Several isothermal amplification techniques recently have been developed that are tolerant of inhibitors present in many plant extracts, which can reduce the need for obtaining purified DNA for running diagnostic assays. One such commercially available technique that has similarities with real-time polymerase chain reaction (PCR) for designing primers and a labeled probe is recombinase polymerase amplification (RPA). This technology was used to develop two simple and rapid approaches for detection of Phytophthora spp.: one genus-specific assay multiplexed with a plant internal control and the other species-specific assays for Phytophthora ramorum and P. kernoviae. All assays were tested for sensitivity (ranging from 3 ng to 1 fg of DNA) and specificity using DNA extracted from more than 136 Phytophthora taxa, 21 Pythium spp., 1 Phytopythium sp., and a wide range of plant species. The lower limit of linear detection using purified DNA was 200 to 300 fg of DNA in all pathogen RPA assays. Six different extraction buffers were tested for use during plant tissue maceration and the assays were validated in the field by collecting 222 symptomatic plant samples from over 50 different hosts. Only 56 samples were culture positive for Phytophthora spp. whereas 91 were positive using the Phytophthora genus-specific RPA test and a TaqMan real-time PCR assay. A technique for the generation of sequencing templates from positive RPA amplifications to confirm species identification was also developed. These RPA assays have added benefits over traditional technologies because they are rapid (results can be obtained in as little as 15 min), do not require DNA extraction or extensive training to complete, use less expensive portable equipment than PCR-based assays, and are significantly more specific than current immunologically based methods. This should provide a rapid, field-deployable capability for pathogen detection that will facilitate point-of-sample collection processing, thereby reducing the time necessary for accurate diagnostics and making management decisions.

  14. Rapid Detection and Identification of Human Hookworm Infections through High Resolution Melting (HRM) Analysis

    PubMed Central

    Ngui, Romano; Lim, Yvonne A. L.; Chua, Kek Heng

    2012-01-01

    Background Hookworm infections are still endemic in low and middle income tropical countries with greater impact on the socioeconomic and public health of the bottom billion of the world's poorest people. In this study, a real-time polymerase chain reaction (PCR) coupled with high resolution melting-curve (HRM) analysis was evaluated for an accurate, rapid and sensitive tool for species identification focusing on the five human hookworm species. Methods Real-time PCR coupled with HRM analysis targeting the second internal transcribed spacer (ITS-2) of nuclear ribosomal DNA as the genetic marker was used to identify and distinguish hookworm species in human samples. Unique and distinct characteristics of HRM patterns were produced for each of the five hookworm species. The melting curves were characterized by peaks of 79.24±0.05°C and 83.00±0.04°C for Necator americanus, 79.12±0.10°C for Ancylostoma duodenale, 79.40±0.10°C for Ancylostoma ceylanicum, 79.63±0.05°C for Ancylostoma caninum and 79.70±0.14°C for Ancylostoma braziliense. An evaluation of the method's sensitivity and specificity revealed that this assay was able to detect as low as 0.01 ng/µl hookworm DNA and amplification was only recorded for hookworm positive samples. Conclusion The HRM assay developed in this study is a rapid and straightforward method for the diagnosis, identification and discrimination of five human hookworms. This assay is simple compared to other probe-based genotyping methods as it does not require multiplexing, DNA sequencing or post-PCR processing. Therefore, this method offers a new alternative for rapid detection of human hookworm species. PMID:22844538

  15. A bioluminescent caspase-1 activity assay rapidly monitors inflammasome activation in cells.

    PubMed

    O'Brien, Martha; Moehring, Danielle; Muñoz-Planillo, Raúl; Núñez, Gabriel; Callaway, Justin; Ting, Jenny; Scurria, Mike; Ugo, Tim; Bernad, Laurent; Cali, James; Lazar, Dan

    2017-08-01

    Inflammasomes are protein complexes induced by diverse inflammatory stimuli that activate caspase-1, resulting in the processing and release of cytokines, IL-1β and IL-18, and pyroptosis, an immunogenic form of cell death. To provide a homogeneous method for detecting caspase-1 activity, we developed a bioluminescent, plate-based assay that combines a substrate, Z-WEHD-aminoluciferin, with a thermostable luciferase in an optimized lytic reagent added directly to cultured cells. Assay specificity for caspase-1 is conferred by inclusion of a proteasome inhibitor in the lytic reagent and by use of a caspase-1 inhibitor to confirm activity. This approach enables a specific and rapid determination of caspase-1 activation. Caspase-1 activity is stable in the reagent thereby providing assay convenience and flexibility. Using this assay system, caspase-1 activation has been determined in THP-1 cells following treatment with α-hemolysin, LPS, nigericin, gramicidin, MSU, R848, Pam3CSK4, and flagellin. Caspase-1 activation has also been demonstrated in treated J774A.1 mouse macrophages, bone marrow-derived macrophages (BMDMs) from mice, as well as in human primary monocytes. Caspase-1 activity was not detected in treated BMDMs derived from Casp1 -/- mice, further confirming the specificity of the assay. Caspase-1 activity can be measured directly in cultured cells using the lytic reagent, or caspase-1 activity released into medium can be monitored by assay of transferred supernatant. The caspase-1 assay can be multiplexed with other assays to monitor additional parameters from the same cells, such as IL-1β release or cell death. The caspase-1 assay in combination with a sensitive real-time monitor of cell death allows one to accurately establish pyroptosis. This assay system provides a rapid, convenient, and flexible method to specifically and quantitatively monitor caspase-1 activation in cells in a plate-based format. This will allow a more efficient and effective assessment of inflammasome activation as well as enable high-throughput screening for inflammasome modulators. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. HPLC-MS/MS method for dexmedetomidine quantification with Design of Experiments approach: application to pediatric pharmacokinetic study.

    PubMed

    Szerkus, Oliwia; Struck-Lewicka, Wiktoria; Kordalewska, Marta; Bartosińska, Ewa; Bujak, Renata; Borsuk, Agnieszka; Bienert, Agnieszka; Bartkowska-Śniatkowska, Alicja; Warzybok, Justyna; Wiczling, Paweł; Nasal, Antoni; Kaliszan, Roman; Markuszewski, Michał Jan; Siluk, Danuta

    2017-02-01

    The purpose of this work was to develop and validate a rapid and robust LC-MS/MS method for the determination of dexmedetomidine (DEX) in plasma, suitable for analysis of a large number of samples. Systematic approach, Design of Experiments, was applied to optimize ESI source parameters and to evaluate method robustness, therefore, a rapid, stable and cost-effective assay was developed. The method was validated according to US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (5-2500 pg/ml), Results: Experimental design approach was applied for optimization of ESI source parameters and evaluation of method robustness. The method was validated according to the US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (R 2 > 0.98). The accuracies, intra- and interday precisions were less than 15%. The stability data confirmed reliable behavior of DEX under tested conditions. Application of Design of Experiments approach allowed for fast and efficient analytical method development and validation as well as for reduced usage of chemicals necessary for regular method optimization. The proposed technique was applied to determination of DEX pharmacokinetics in pediatric patients undergoing long-term sedation in the intensive care unit.

  17. Evaluation of four novel isothermal amplification assays towards simple and rapid genotyping of chloroquine resistant Plasmodium falciparum.

    PubMed

    Chahar, Madhvi; Anvikar, Anup; Dixit, Rajnikant; Valecha, Neena

    2018-07-01

    Loop mediated isothermal amplification (LAMP) assay is sensitive, prompt, high throughput and field deployable technique for nucleic acid amplification under isothermal conditions. In this study, we have developed and optimized four different visualization methods of loop-mediated isothermal amplification (LAMP) assay to detect Pfcrt K76T mutants of P. falciparum and compared their important features for one-pot in-field applications. Even though all the four tested LAMP methods could successfully detect K76T mutants of P. falciparum, however considering the time, safety, sensitivity, cost and simplicity, the malachite green and HNB based methods were found more efficient. Among four different visual dyes uses to detect LAMP products accurately, hydroxynaphthol blue and malachite green could produce long stable color change and brightness in a close tube-based approach to prevent cross-contamination risk. Our results indicated that the LAMP offers an interesting novel and convenient best method for the rapid, sensitive, cost-effective, and fairly user friendly tool for detection of K76T mutants of P. falciparum and therefore presents an alternative to PCR-based assays. Based on our comparative analysis, better field based LAMP visualization method can be chosen easily for the monitoring of other important drug targets (Kelch13 propeller region). Copyright © 2018 Elsevier Inc. All rights reserved.

  18. A novel double recognition enzyme-linked immunosorbent assay based on the nucleocapsid protein for early detection of European porcine reproductive and respiratory syndrome virus infection.

    PubMed

    Venteo, A; Rebollo, B; Sarraseca, J; Rodriguez, M J; Sanz, A

    2012-04-01

    Precise and rapid detection of porcine reproductive respiratory syndrome virus (PRRSV) infection in swine farms is critical. Improvement of control procedures, such as testing incoming gilt and surveillance of seronegative herds requires more rapid and sensitive methods. However, standard serological techniques detect mainly IgG antibodies. A double recognition enzyme-linked immunosorbent assay (DR-ELISA) was developed for detection of antibodies specific to European PRRSV. This new assay can recognize both IgM and IgG antibodies to PRSSV which might be useful for detecting in routine surveillance assays pigs that are in the very early stages of infection and missed by conventional assays detecting only IgG antibodies. DR-ELISA is based on the double recognition of antigen by antibody. In this study, the recombinant nucleocapsid protein (N) of PRRSV was used both as the coating and the enzyme-conjugated antigen. To evaluate the sensitivity of the assay at early stages of the infection, sera from 69 pigs infected with PRRSV were collected during successive days post infection (pi) and tested. While standard methods showed low sensitivity rates before day 14 pi, DR-ELISA detected 88.4% seropositive samples at day 7 showing greater sensitivity at early stages of the infection. Further studies were carried out to assess the efficiency of the new assay, and the results showed DR-ELISA to be a sensitive and accurate method for early diagnosis of EU-PRRSV infection. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Detection of Legume Protease Inhibitors by the Gel-X-ray Film Contact Print Technique

    ERIC Educational Resources Information Center

    Mulimani, Veerappa H.; Sudheendra, Kulkarni; Giri, Ashok P.

    2002-01-01

    Redgram (Cajanus cajan L.) extracts have been analyzed for the protease inhibitors using a new, sensitive, simple, and rapid method for detection of electrophoretically separated protease inhibitors. The detection involves equilibrating the gel successively in the protease assay buffer and protease solution, rinsing the gel in assay buffer, and…

  20. Epitope-blocking enzyme-linked immunosorbent assay for detection of antibodies to Ross River virus in vertebrate sera.

    PubMed

    Oliveira, Nidia M M; Broom, Annette K; Mackenzie, John S; Smith, David W; Lindsay, Michael D A; Kay, Brian H; Hall, Roy A

    2006-07-01

    We describe the development of an epitope-blocking enzyme-linked immunosorbent assay (ELISA) for the sensitive and rapid detection of antibodies to Ross River virus (RRV) in human sera and known vertebrate host species. This ELISA provides an alternative method for the serodiagnosis of RRV infections.

  1. Factors Affecting Accuracy and Time Requirements of a Glucose Oxidase-Peroxidase Assay for Determination of Glucose

    USDA-ARS?s Scientific Manuscript database

    Accurate and rapid assays for glucose are desirable for analysis of glucose and starch in food and feedstuffs. An established colorimetric glucose oxidase-peroxidase method for glucose was modified to reduce analysis time, and evaluated for factors that affected accuracy. Time required to perform t...

  2. Quantitation & Case-Study-Driven Inquiry to Enhance Yeast Fermentation Studies

    ERIC Educational Resources Information Center

    Grammer, Robert T.

    2012-01-01

    We propose a procedure for the assay of fermentation in yeast in microcentrifuge tubes that is simple and rapid, permitting assay replicates, descriptive statistics, and the preparation of line graphs that indicate reproducibility. Using regression and simple derivatives to determine initial velocities, we suggest methods to compare the effects of…

  3. Simple and rapid method for the detection of Filobasidiella neoformans in a probiotic dairy product by using loop-mediated isothermal amplification.

    PubMed

    Ishikawa, Hiroshi; Kasahara, Kohei; Sato, Sumie; Shimakawa, Yasuhisa; Watanabe, Koichi

    2014-05-16

    Yeast contamination is a serious problem in the food industry and a major cause of food spoilage. Several yeasts, such as Filobasidiella neoformans, which cause cryptococcosis in humans, are also opportunistic pathogens, so a simple and rapid method for monitoring yeast contamination in food is essential. Here, we developed a simple and rapid method that utilizes loop-mediated isothermal amplification (LAMP) for the detection of F. neoformans. A set of five specific LAMP primers was designed that targeted the 5.8S-26S rDNA internal transcribed spacer 2 region of F. neoformans, and the primer set's specificity was confirmed. In a pure culture of F. neoformans, the LAMP assay had a lower sensitivity threshold of 10(2)cells/mL at a runtime of 60min. In a probiotic dairy product artificially contaminated with F. neoformans, the LAMP assay also had a lower sensitivity threshold of 10(2)cells/mL, which was comparable to the sensitivity of a quantitative PCR (qPCR) assay. We also developed a simple two-step method for the extraction of DNA from a probiotic dairy product that can be performed within 15min. This method involves initial protease treatment of the test sample at 45°C for 3min followed by boiling at 100°C for 5min under alkaline conditions. In a probiotic dairy product artificially contaminated with F. neoformans, analysis by means of our novel DNA extraction method followed by LAMP with our specific primer set had a lower sensitivity threshold of 10(3)cells/mL at a runtime of 60min. In contrast, use of our novel method of DNA extraction followed by qPCR assay had a lower sensitivity threshold of only 10(5)cells/mL at a runtime of 3 to 4h. Therefore, unlike the PCR assay, our LAMP assay can be used to quickly evaluate yeast contamination and is sensitive even for crude samples containing bacteria or background impurities. Our study provides a powerful tool for the primary screening of large numbers of food samples for yeast contamination. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Simultaneous detection and serotyping of dengue infection using single tube multiplex CDC Dengue Real-Time RT-PCR from India.

    PubMed

    Sharma, Shashi; Tandel, Kundan; Danwe, Surabhi; Bhatt, Puneet; Dash, P K; Ranjan, Praveer; Rathi, K R; Gupta, Rajiv Mohan; Parida, M M

    2018-03-01

    Four antigenically different dengue virus serotypes (DENV-1, DENV-2, DENV-3 and DENV-4) are known to cause infections in humans. Some of these are known to cause more severe disease than the others. Chances for developing Dengue hemorrhagic fever-dengue shock syndrome (DHF-DSS) increases significantly with history of previous infection with one of the four serotypes. Therefore, early diagnosis, serotyping and providing early warning of dengue fever epidemics to concerned authorities becomes very important for better patient outcome and to curb the rapid spread in the community. During the 2014 outbreak, a total of 100 samples from suspected cases of dengue were collected. NS1 antigen based rapid test was used for serological diagnosis. Dengue complex one step reverse transcription-polymerase chain reaction was performed to look for presence of viral RNA. Single tube multiplex RT-PCR was also performed to look for infecting serotype. CDC Dengue Multiplex Real Time PCR assay was performed for rapid diagnosis and simultaneous serotyping of the dengue virus. Out of the 100 samples screened, 69 were found to be positive by NS1Ag Rapid test. 34 samples were found positive by dengue consensus RT-PCR assay. 22 samples were found to be positive by single tube Dengue multiplex RT-PCR assay. Serotype DEN-2 was present in maximum numbers followed by DEN-3. 44 samples were found positive by DENV CDC Multiplex Real time PCR assay. DEN-2 was found in maximum numbers followed by DEN-1. Dengue remains to be an important health problem in India and across the globe. Few serotypes of dengue are more dangerous than the others. Rapid diagnosis and serotyping remains the key for better patient management and prevention of disease spreading in the community. Highly sensitive, specific and rapid CDC real time RT-PCR assay was found to be most promising tool among all available molecular diagnostic methods. This will serve a rapid and reliable simultaneous dengue virus detection as well serotyping assay in near future for rapid identification of dengue suspected sample screening.

  5. Validation of the Applied Biosystems 7500 Fast Instrument for Detection of Listeria Species with the SureTect Listeria Species PCR Assay.

    PubMed

    Cloke, Jonathan; Arizanova, Julia; Crabtree, David; Simpson, Helen; Evans, Katharine; Vaahtoranta, Laura; Palomäki, Jukka-Pekka; Artimo, Paulus; Huang, Feng; Liikanen, Maria; Koskela, Suvi; Chen, Yi

    2016-01-01

    The Thermo Scientific™ SureTect™ Listeria species Real-Time PCR Assay was certified during 2013 by the AOAC Research Institute (RI) Performance Tested Methods(SM) program as a rapid method for the detection of Listeria species from a wide range of food matrixes and surface samples. A method modification study was conducted in 2015 to extend the matrix claims of the product to a wider range of food matrixes. This report details the method modification study undertaken to extend the use of this PCR kit to the Applied Biosystems™ 7500 Fast PCR Instrument and Applied Biosystems RapidFinder™ Express 2.0 software allowing use of the assay on a 96-well format PCR cycler in addition to the current workflow, using the 24-well Thermo Scientific PikoReal™ PCR Instrument and Thermo Scientific SureTect software. The method modification study presented in this report was assessed by the AOAC-RI as being a level 2 method modification study, necessitating a method developer study on a representative range of food matrixes covering raw ground turkey, 2% fat pasteurized milk, and bagged lettuce as well as stainless steel surface samples. All testing was conducted in comparison to the reference method detailed in International Organization for Standardization (ISO) 6579:2002. No significant difference by probability of detection statistical analysis was found between the SureTect Listeria species PCR Assay or the ISO reference method methods for any of the three food matrixes and the surface samples analyzed during the study.

  6. Rapid detection of Shigella and enteroinvasive Escherichia coli in produce enrichments by a conventional multiplex PCR assay.

    PubMed

    Binet, Rachel; Deer, Deanne M; Uhlfelder, Samantha J

    2014-06-01

    Faster detection of contaminated foods can prevent adulterated foods from being consumed and minimize the risk of an outbreak of foodborne illness. A sensitive molecular detection method is especially important for Shigella because ingestion of as few as 10 of these bacterial pathogens can cause disease. The objectives of this study were to compare the ability of four DNA extraction methods to detect Shigella in six types of produce, post-enrichment, and to evaluate a new and rapid conventional multiplex assay that targets the Shigella ipaH, virB and mxiC virulence genes. This assay can detect less than two Shigella cells in pure culture, even when the pathogen is mixed with background microflora, and it can also differentiate natural Shigella strains from a control strain and eliminate false positive results due to accidental laboratory contamination. The four DNA extraction methods (boiling, PrepMan Ultra [Applied Biosystems], InstaGene Matrix [Bio-Rad], DNeasy Tissue kit [Qiagen]) detected 1.6 × 10(3)Shigella CFU/ml post-enrichment, requiring ∼18 doublings to one cell in 25 g of produce pre-enrichment. Lower sensitivity was obtained, depending on produce type and extraction method. The InstaGene Matrix was the most consistent and sensitive and the multiplex assay accurately detected Shigella in less than 90 min, outperforming, to the best of our knowledge, molecular assays currently in place for this pathogen. Published by Elsevier Ltd.

  7. Rapid and Specific Method for Evaluating Streptomyces Competitive Dynamics in Complex Soil Communities

    USDA-ARS?s Scientific Manuscript database

    Quantifying target microbial populations in complex communities remains a barrier to studying species interactions in soil environments. Quantitative real-time PCR (qPCR) offers a rapid and specific means to assess populations of target microorganisms. SYBR Green and TaqMan-based qPCR assays were de...

  8. Surface plasmon resonance imaging for label-free detection of foodborne pathogens and toxins

    USDA-ARS?s Scientific Manuscript database

    More rapid and efficient detection methods for foodborne pathogenic bacteria and toxins are needed to address the long assay time and limitations in multiplex capacity. Surface plasmon resonance imaging (SPRi) is an emerging optical technique, which allows for rapid and label-free screening of multi...

  9. RAPID PCR-BASED MONITORING OF INFECTIOUS ENTEROVIRUSES IN DRINKING WATER. (R824756)

    EPA Science Inventory

    Abstract

    Currently, the standard method for the detection of enteroviruses and hepatitis A virus in water involves cell culture assay which is expensive and time consuming. Direct RT-PCR offers a rapid and sensitive alternative to virus detection but sensitivity is oft...

  10. Review of Angiotensin-converting Enzyme Inhibitory Assay: Rapid Method in Drug Discovery of Herbal Plants

    PubMed Central

    Ahmad, Islamudin; Yanuar, Arry; Mulia, Kamarza; Mun’im, Abdul

    2017-01-01

    The renin-angiotensin-aldosterone system is a signaling pathway which responsible in the blood pressure regulation. Angiotensin-converting enzyme (ACE) is one of the key elements responsible for the hypertensive mechanism. It converts angiotensin-I to angiotensin-II. The discovery history of the ACE inhibitory activity assay method has been through a long stage for decades and development continues until today. The ACE inhibitory activity has become an effective screening method in the search for new antihypertensive agents from herbal plants. Some of in vitro assay methods were used to examine the activity of ACE inhibitors based on the substrate usage, such as; Cushman and Cheung Method using a substrate hippuryl-histidyl-leucine (HHL), Holmquist method using a substrate furanacryloyl-tripeptide, Elbl and Wagner method using a substrate benzoil-[l-14C] glicyl-L-histidine-L-leucine, Carmel and Yaron method using a substrate o-aminobenzoylglycyl-p-nitrophenylalanilproline, and Lam method using 3-hydroxybutyrylglycyl-glycyl-glycine as substrate. Several different methods to measure the results of enzymatic reactions or separating substrate with products, including spectrophotometric, fluorometric, high-performance liquid chromatography, electrophoresis, and radiochemistry. Application of the test method for screening the ACE inhibitors activity and investigation of active compounds from natural products can be done easily with this method, it is very helpful in research because the results obtained are simple, accurate, and rapid. PMID:28503045

  11. Flow Cytometry Techniques in Radiation Biology

    DTIC Science & Technology

    1988-06-01

    Henidtopoietic stem cells SUMMARY Hematopoietic stem cells ( HSC ) are present in the marrow at a concentration of approximately 2-3 HSC per 1000 nucleated marrow...cells. In the past, only clonogenic assays requiring 8-13 days and ten irradiated recipient rodents were available for assaying HSC . Because of the...importance of HSC in the postirradiation syndrome, we have developed a new rapid method based on flow cytometry not only to assay but also to purify and

  12. Evaluating an alternative method for rapid urinary creatinine determination

    EPA Science Inventory

    Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...

  13. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990

  14. Justification of rapid prototyping in the development cycle of thermoplastic-based lab-on-a-chip.

    PubMed

    Preywisch, Regina; Ritzi-Lehnert, Marion; Drese, Klaus S; Röser, Tina

    2011-11-01

    During the developmental cycle of lab-on-a-chip devices, various microstructuring techniques are required. While in the designing and assay implementation phase direct structuring or so-called rapid-prototyping methods such as milling or laser ablation are applied, replication methods like hot embossing or injection moulding are favourable for large quantity manufacturing. This work investigated the applicability of rapid-prototyping techniques for thermoplastic chip development in general, and the reproducibility of performances in dependency of the structuring technique. A previously published chip for prenatal diagnosis that preconcentrates DNA via electrokinetic trapping and field-amplified-sample-stacking and afterwards separates it in CGE was chosen as a model. The impact of structuring, sealing, and the integration of membranes on the mobility of the EOF, DNA preconcentration, and DNA separation was studied. Structuring methods were found to significantly change the location where preconcentration of DNA occurs. However, effects on the mobility of the EOF and the separation quality of DNA were not observed. Exchange of the membrane has no effect on the chip performance, whereas the sealing method impairs the separation of DNA within the chip. The overall assay performance is not significantly influenced by different structuring methods; thus, the application of rapid-prototyping methods during a chip development cycle is well justified. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. [Multiplex real-time PCR method for rapid detection of Marburg virus and Ebola virus].

    PubMed

    Yang, Yu; Bai, Lin; Hu, Kong-Xin; Yang, Zhi-Hong; Hu, Jian-Ping; Wang, Jing

    2012-08-01

    Marburg virus and Ebola virus are acute infections with high case fatality rates. A rapid, sensitive detection method was established to detect Marburg virus and Ebola virus by multiplex real-time fluorescence quantitative PCR. Designing primers and Taqman probes from highly conserved sequences of Marburg virus and Ebola virus through whole genome sequences alignment, Taqman probes labeled by FAM and Texas Red, the sensitivity of the multiplex real-time quantitative PCR assay was optimized by evaluating the different concentrations of primers and Probes. We have developed a real-time PCR method with the sensitivity of 30.5 copies/microl for Marburg virus positive plasmid and 28.6 copies/microl for Ebola virus positive plasmids, Japanese encephalitis virus, Yellow fever virus, Dengue virus were using to examine the specificity. The Multiplex real-time PCR assays provide a sensitive, reliable and efficient method to detect Marburg virus and Ebola virus simultaneously.

  16. Detection of dopamine in dopaminergic cell using nanoparticles-based barcode DNA analysis.

    PubMed

    An, Jeung Hee; Kim, Tae-Hyung; Oh, Byung-Keun; Choi, Jeong Woo

    2012-01-01

    Nanotechnology-based bio-barcode-amplification analysis may be an innovative approach to dopamine detection. In this study, we evaluated the efficacy of this bio-barcode DNA method in detecting dopamine from dopaminergic cells. Herein, a combination DNA barcode and bead-based immunoassay for neurotransmitter detection with PCR-like sensitivity is described. This method relies on magnetic nanoparticles with antibodies and nanoparticles that are encoded with DNA, and antibodies that can sandwich the target protein captured by the nanoparticle-bound antibodies. The aggregate sandwich structures are magnetically separated from solution, and treated in order to remove the conjugated barcode DNA. The DNA barcodes were then identified via PCR analysis. The dopamine concentration in dopaminergic cells can be readily and rapidly detected via the bio-barcode assay method. The bio-barcode assay method is, therefore, a rapid and high-throughput screening tool for the detection of neurotransmitters such as dopamine.

  17. Cardiotoxicity screening: a review of rapid-throughput in vitro approaches.

    PubMed

    Li, Xichun; Zhang, Rui; Zhao, Bin; Lossin, Christoph; Cao, Zhengyu

    2016-08-01

    Cardiac toxicity represents one of the leading causes of drug failure along different stages of drug development. Multiple very successful pharmaceuticals had to be pulled from the market or labeled with strict usage warnings due to adverse cardiac effects. In order to protect clinical trial participants and patients, the International Conference on Harmonization published guidelines to recommend that all new drugs to be tested preclinically for hERG (Kv11.1) channel sensitivity before submitting for regulatory reviews. However, extensive studies have demonstrated that measurement of hERG activity has limitations due to the multiple molecular targets of drug compound through which it may mitigate or abolish a potential arrhythmia, and therefore, a model measuring multiple ion channel effects is likely to be more predictive. Several phenotypic rapid-throughput methods have been developed to predict the potential cardiac toxic compounds in the early stages of drug development using embryonic stem cells- or human induced pluripotent stem cell-derived cardiomyocytes. These rapid-throughput methods include microelectrode array-based field potential assay, impedance-based or Ca(2+) dynamics-based cardiomyocytes contractility assays. This review aims to discuss advantages and limitations of these phenotypic assays for cardiac toxicity assessment.

  18. Irradiation influence on the detection of genetic-modified soybeans

    NASA Astrophysics Data System (ADS)

    Villavicencio, A. L. C. H.; Araújo, M. M.; Baldasso, J. G.; Aquino, S.; Konietzny, U.; Greiner, R.

    2004-09-01

    Three soybean varieties were analyzed to evaluate the irradiation influence on the detection of genetic modification. Samples were treated in a 60Co facility at dose levels of 0, 500, 800, and 1000Gy. The seeds were at first analyzed by Comet Assay as a rapid screening irradiation detection method. Secondly, germination test was performed to detect the viability of irradiated soybeans. Finally, because of its high sensitivity, its specificity and rapidity the polimerase chain reaction was the method applied for genetic modified organism detection. The analysis of DNA by the single technique of microgel electrophoresis of single cells (DNA Comet Assay) showed that DNA damage increased with increasing radiation doses. No negative influence of irradiation on the genetic modification detection was found.

  19. Multi-wavelength dye concentration determination for enzymatic assays: evaluation of chromogenic para-nitrophenol over a wide pH range.

    PubMed

    Max, Jean-Joseph; Meddeb-Mouelhi, Fatma; Beauregard, Marc; Chapados, Camille

    2012-12-01

    Enzymatic assays need robust, rapid colorimetric methods that can follow ongoing reactions. For this, we developed a highly accurate, multi-wavelength detection method that could be used for several systems. Here, it was applied to the detection of para-nitrophenol (pNP) in basic and acidic solutions. First, we confirmed by factor analysis that pNP has two forms, with unique spectral characteristics in the 240 to 600 nm range: Phenol in acidic conditions absorbs in the lower range, whereas phenolate in basic conditions absorbs in the higher range. Thereafter, the method was used for the determination of species concentration. For this, the intensity measurements were made at only two wavelengths with a microtiter plate reader. This yielded total dye concentration, species relative abundance, and solution pH value. The method was applied to an enzymatic assay. For this, a chromogenic substrate that generates pNP after hydrolysis catalyzed by a lipase from the fungus Yarrowia lipolytica was used. Over the pH range of 3-11, accurate amounts of acidic and basic pNP were determined at 340 and 405 nm, respectively. This method surpasses the commonly used single-wavelength assay at 405 nm, which does not detect pNP acidic species, leading to activity underestimations. Moreover, alleviation of this pH-related problem by neutralization is not necessary. On the whole, the method developed is readily applicable to rapid high-throughput of enzymatic activity measurements over a wide pH range.

  20. Performance and Specificity of the Covalently Linked Immunomagnetic Separation-ATP Method for Rapid Detection and Enumeration of Enterococci in Coastal Environments

    PubMed Central

    Zimmer-Faust, Amity G.; Thulsiraj, Vanessa; Ferguson, Donna

    2014-01-01

    The performance and specificity of the covalently linked immunomagnetic separation-ATP (Cov-IMS/ATP) method for the detection and enumeration of enterococci was evaluated in recreational waters. Cov-IMS/ATP performance was compared with standard methods: defined substrate technology (Enterolert; IDEXX Laboratories), membrane filtration (EPA Method 1600), and an Enterococcus-specific quantitative PCR (qPCR) assay (EPA Method A). We extend previous studies by (i) analyzing the stability of the relationship between the Cov-IMS/ATP method and culture-based methods at different field sites, (ii) evaluating specificity of the assay for seven ATCC Enterococcus species, (iii) identifying cross-reacting organisms binding the antibody-bead complexes with 16S rRNA gene sequencing and evaluating specificity of the assay to five nonenterococcus species, and (iv) conducting preliminary tests of preabsorption as a means of improving the assay. Cov-IMS/ATP was found to perform consistently and with strong agreement rates (based on exceedance/compliance with regulatory limits) of between 83% and 100% compared to the culture-based Enterolert method at a variety of sites with complex inputs. The Cov-IMS/ATP method is specific to five of seven different Enterococcus spp. tested. However, there is potential for nontarget bacteria to bind the antibody, which may be reduced by purification of the IgG serum with preabsorption at problematic sites. The findings of this study help to validate the Cov-IMS/ATP method, suggesting a predictable relationship between the Cov-IMS/ATP method and traditional culture-based methods, which will allow for more widespread application of this rapid and field-portable method for coastal water quality assessment. PMID:24561583

  1. A Rapid Growth-Independent Antibiotic Resistance Detection Test by SYBR Green/Propidium Iodide Viability Assay.

    PubMed

    Feng, Jie; Yee, Rebecca; Zhang, Shuo; Tian, Lili; Shi, Wanliang; Zhang, Wen-Hong; Zhang, Ying

    2018-01-01

    Antibiotic-resistant bacteria have caused huge concerns and demand innovative approaches for their prompt detection. Current antimicrobial susceptibility tests (AST) rely on the growth of the organisms which takes 1-2 days for fast-growing organisms and several weeks for slow growing organisms. Here, we show for the first time the utility of the SYBR Green I/propidium iodide (PI) viability assay for rapidly identifying antibiotic resistance in less than 30 min for major, antibiotic-resistant, fast-growing bacteria, such as Staphylococcus aureus, Escherichia coli, Klebsiella pneumoniae , and Acinetobacter baumannii for bactericidal and bacteriostatic agents and in 16 h for extremely rapid detection of drug resistance for isoniazid and pyrazinamide in slow-growing Mycobacterium tuberculosis . The SYBR Green I/PI assay generated rapid and robust results in concordance with traditional AST methods. This novel growth-independent methodology changes the concept of the current growth-based AST and may revolutionize current drug susceptibility testing for all cells of prokaryotic and eukaryotic origin and, subject to further clinical validation, may play a major role in saving lives and improving patient outcomes.

  2. Development of a double-antibody sandwich ELISA for rapid detection of Bacillus Cereus in food

    PubMed Central

    Zhu, Longjiao; He, Jing; Cao, Xiaohan; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-01-01

    Bacillus cereus is increasingly recognized as one of the major causes of food poisoning in the industrialized world. In this paper, we describe a sensitive double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) that was developed for rapid detection of B. cereus in food to minimize the risk of contamination. The polyclonal antibody (pAb) and monoclonal antibodies (mAbs) specific to B. cereus were generated from rabbit antiserum and mouse ascites, respectively, using the octanoic acid/saturated ammonium sulfate precipitation method and protein A-sepharose columns. IgG-isotype mAbs were specially developed to undergo a novel peripheral multiple sites immunization for rapid gain of hybridomas and a subtractive screen was used to eliminate cross reactivity with closely related species such as Bacillus thuringiensis, B. subtilis, B. licheniformis and B. perfringens. The linear detection range of the method was approximately 1 × 104–2.8 × 106 cells/mL with a detection limit (LOD) of 0.9 × 103 cells/mL. The assay was able to detect B. cereus when the samples were prepared in meat with various pathogens. The newly developed analytical method provides a rapid method to sensitively detect B. cereus in food specimens. PMID:26976753

  3. Rapid screening test for detection of oxytetracycline residues in milk using lateral flow assay.

    PubMed

    Naik, Laxmana; Sharma, Rajan; Mann, Bimlesh; Lata, Kiran; Rajput, Y S; Surendra Nath, B

    2017-03-15

    A rapid, semi-quantitative lateral flow assay (LFA) was developed to screen the oxytetracycline (OTC) antibiotics residues in milk samples. In this study a competitive immuno-assay format was established. Colloidal gold nano-particles (GNP) were prepared and used as labelling material in LFA. Polyclonal antibodies were generated against OTC molecule (anti-OTC), purified and the quality was assessed by enzyme linked immuno sorbet assay. For the first time membrane components required for LFA in milk system was optimized. GNP and anti-OTC stable conjugate preparation method was standardized, and then these components were placed over the conjugate pad. OTC coupled with carrier protein was placed on test line; species specific secondary antibodies were placed on the control line of the membrane matrix. Assay was validated by spiking OTC to antibiotic free milk samples and results could be accomplished within 5min. without need of any equipment. The visual detection limit was 30ppb. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Method for Rapid Detection of Severe Acute Respiratory Syndrome Coronavirus

    PubMed Central

    Thai, Hong Thi Cam; Le, Mai Quynh; Vuong, Cuong Duc; Parida, Manmohan; Minekawa, Harumi; Notomi, Tsugunori; Hasebe, Futoshi; Morita, Kouichi

    2004-01-01

    The development and evaluation of a one-step single-tube accelerated real-time quantitative reverse transcription (RT) loop-mediated isothermal amplification (LAMP) assay is reported for rapid detection of the severe acute respiratory syndrome coronavirus (SARS-CoV) replicase gene. A total of 49 samples (15 throat washes, 13 throat swabs, and 21 combined throat and nasal swabs) collected from patients admitted to the Hanoi-French and Ninhbinh hospitals in Vietnam during the SARS epidemic were evaluated and compared to conventional RT-PCR. The RT-LAMP assay demonstrated 100-fold-greater sensitivity, with a detection limit of 0.01 PFU. The sensitivity and specificity of RT-LAMP assay for detecting viral RNA in clinical specimens with regard to RT-PCR were 100 and 87%, respectively. The specificity of the RT-LAMP assay was further validated by restriction analysis as well as nucleotide sequencing of the amplified product. The concentration of virus in most of the clinical samples was 0.1 PFU (0.1 to 102 PFU), as determined from the standard curve of SARS RT-LAMP and based on the time of positivity. The assay procedure is quite simple, wherein the amplification is carried out in a single tube under isothermal conditions at 63°C, and the result can be obtained in less than 1 h (as early as 11 min). Thus, the RT-LAMP assay reported here has the advantages of rapid amplification, simple operation, and easy detection and will be useful for rapid and reliable clinical diagnosis of SARS-CoV in developing countries. PMID:15131154

  5. Detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification (LAMP) assay and serology in pediatric community-acquired pneumonia.

    PubMed

    Gotoh, Kensei; Nishimura, Naoko; Ohshima, Yasunori; Arakawa, Yasuko; Hosono, Haruki; Yamamoto, Yasuto; Iwata, Yasushi; Nakane, Kazumasa; Funahashi, Keiji; Ozaki, Takao

    2012-10-01

    Rapid diagnosis of Mycoplasma pneumoniae pneumonia is required for treatment with effective antimicrobial agents without delay; however, this capacity has not yet been established in clinical practice. Recently, a novel nucleic acid amplification method termed loop-mediated isothermal amplification (LAMP) has been used to rapidly diagnose various infectious diseases. In this study, we prospectively evaluated the efficacy of the LAMP assay to rapidly diagnose M. pneumoniae pneumonia in clinical practice. Three hundred sixty-eight children (median age, 3.8 years; range, 0.1-14.3 years) admitted to our hospital between April 2009 and March 2010 for community-acquired pneumonia were enrolled in this study. We obtained throat swabs on admission to detect M. pneumoniae DNA and paired serum samples on admission and at discharge to assay M. pneumoniae antibody titers. M. pneumoniae pneumonia was diagnosed by either a positive LAMP assay or a fourfold or greater increase in antibody titer. Overall, 46 children (12.5% of the patients with pneumonia) were diagnosed with M. pneumoniae pneumonia; of these, 27 (58.7%) were aged less than 6 years. Of the aforementioned 46 children, 38 (82.6%) and 37 (80.4%) were identified by LAMP and serology, respectively. When the results of serology were taken as the standard, the sensitivity and specificity and positive and negative predictive values of the LAMP assay were 78.4%, 97.3%, 76.3%, and 97.6%, respectively. We concluded the LAMP assay may be useful for rapid diagnosis of M. pneumoniae pneumonia.

  6. Development of a Rapid Insulin Assay by Homogenous Time-Resolved Fluorescence

    PubMed Central

    Vallaghe, Julie; Gregor, Nathalie; Donthamsetti, Prashant; Harris, Paul E.; Pierre, Nicolas; Freyberg, Robin; Charrier-Savournin, Fabienne; Javitch, Jonathan A.; Freyberg, Zachary

    2016-01-01

    Direct measurement of insulin is critical for basic and clinical studies of insulin secretion. However, current methods are expensive and time-consuming. We developed an insulin assay based on homogenous time-resolved fluorescence that is significantly more rapid and cost-effective than current commonly used approaches. This assay was applied effectively to an insulin secreting cell line, INS-1E cells, as well as pancreatic islets, allowing us to validate the assay by elucidating mechanisms by which dopamine regulates insulin release. We found that dopamine functioned as a significant negative modulator of glucose-stimulated insulin secretion. Further, we showed that bromocriptine, a known dopamine D2/D3 receptor agonist and newly approved drug used for treatment of type II diabetes mellitus, also decreased glucose-stimulated insulin secretion in islets to levels comparable to those caused by dopamine treatment. PMID:26849707

  7. Comparative Evaluation of Serological and Molecular Methods for the Diagnosis of Scrub Typhus in Indian Settings.

    PubMed

    Gupta, Nitin; Chaudhry, Rama; Kabra, Sushil K; Lodha, Rakesh; Mirdha, Bijay Ranjan; Das, Bimal Kumar; Dey, Aparajit Ballay; Sreenivas, Vishnubhatla

    2017-03-24

    The major brunt of scrub typhus is borne by developing countries like India but the disease remains neglected. The rapid progression of this infection to serious complications and associated mortality calls for improved diagnostics. The immunoglobulin (Ig)M immunofluorescence assay (IFA), with all of its limitations remains the gold standard. Of 218 suspected cases from patients enrolled in a 2-year study, 30 cases of scrub typhus were detected by IgM IFA, using a 1:64 dilution. The sensitivities of the IgM enzyme-linked immunosorbent assay, IgM rapid flow assay (RFA), and IgG RFA were found to be 97%, 87%, and 77%, respectively. Their respective specificities were 100%, 100%, and 92%, respectively. The sensitivity and specificity of a nested PCR assay targeting a gene encoding a 56-kDa protein were found to be 50% and 100%, respectively.

  8. Visual detection of organophosphorus pesticides represented by mathamidophos using Au nanoparticles as colorimetric probe.

    PubMed

    Li, Hongkun; Guo, Jiajia; Ping, Hong; Liu, Lurui; Zhang, Minwei; Guan, Fengrui; Sun, Chunyan; Zhang, Qian

    2011-12-15

    With citrate-coated Au nanoparticles as colorimetric probe, a novel visual method for rapid assay of organophosphorus pesticides has been developed. The assay principle is based on catalytic hydrolysis of acetylthiocholine into thiocholine by acetylcholinesterase, which induces the aggregation of Au nanoparticles and the color change from claret-red to purple or even grey. The original plasmon absorption of Au nanoparticles at 522 nm decreases, and simultaneously, a new absorption band appears at 675 nm. The irreversible inhibition of organophosphorus pesticides on acetylcholinesterase prevents aggregation of Au nanoparticles. Under optimum conditions, the absorbance at 522 nm of Au nanoparticles is related linearly to the concentration of mathamidophos in the range of 0.02-1.42 μg/mL with a detection limit of 1.40 ng/mL. This colorimetric method has been successfully utilized to detect mathamidophos in vegetables with satisfactory results. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for the analysis of organophosphorus pesticides. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Sensitivity and Specificity of Human Immunodeficiency Virus Rapid Serologic Assays and Testing Algorithms in an Antenatal Clinic in Abidjan, Ivory Coast

    PubMed Central

    Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.

    2001-01-01

    To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995

  10. Quantification of measles, mumps and rubella viruses using real-time quantitative TaqMan-based RT-PCR assay.

    PubMed

    Ammour, Y; Faizuloev, E; Borisova, T; Nikonova, A; Dmitriev, G; Lobodanov, S; Zverev, V

    2013-01-01

    In this study, a rapid quantitative method using TaqMan-based real-time reverse transcription-polymerase chain reaction (qPCR-RT) has been developed for estimating the titers of measles, mumps and rubella (MMR) viruses in infected cell culture supernatants. The qPCR-RT assay was demonstrated to be a specific, sensitive, efficient and reproducible method. For MMR viral samples obtained during MMR viral propagations in Vero cells at a different multiplicity of infection, titers determined by the qPCR-RT assay have been compared with estimates of infectious virus obtained by a traditional commonly used method for MMR viruses - 50% cell culture infective dose (CCID(50)) assay, in paired samples. Pearson analysis evidenced a significant correlation between both methods for a certain period after viral inoculation. Furthermore, the established qPCR-RT assay was faster and less-laborious. The developed method could be used as an alternative method or a supplementary tool for the routine titer estimation during MMR vaccine production. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Visual endpoint detection of Escherichia coli O157:H7 using isothermal Genome Exponential Amplification Reaction (GEAR) assay and malachite green.

    PubMed

    Jothikumar, Prithiviraj; Narayanan, Jothikumar; Hill, Vincent R

    2014-03-01

    Rapid and specific detection methods for bacterial agents in drinking water are important for disease prevention and responding to suspected contamination events. In this study, an isothermal Genome Exponential Amplification Reaction (GEAR) assay for Escherichia coli O157:H7 was designed specifically to recognize a 199-bp fragment of the lipopolysaccharide gene (rfbE) for rapid testing of water samples. The GEAR assay was found to be specific for E. coli O157:H7 using 10 isolates of E. coli O157:H7 and a panel of 86 bacterial controls. The GEAR assay was performed at a constant temperature of 65°C using SYTO 9 intercalating dye. Detection limits were determined to be 20 CFU for the GEAR assay. When SYTO 9 fluorescence was measured using a real-time PCR instrument, the assay had the same detection limit as when malachite green was added to the reaction mix and a characteristic blue color was visually observed in positive reactions. The study also found that 50 and 20 CFU of E. coli O157:H7 seeded into 100-liter of tap water could be detected by the GEAR assays after the sample was concentrated by hollow-fiber ultrafiltration (HFUF) and approximately 10% of HFUF concentrate was cultured using trypticase soy broth-novobiocin. When applied to 19 surface water samples collected from Tennessee and Kentucky, the GEAR assay and a published real-time PCR assay both detected E. coli O157:H7 in two of the samples. The results of this study indicate that the GEAR assay can be sensitive for rapid detection of E. coli O157:H7 in water samples using fluorometric instruments and visual endpoint determination. Published by Elsevier B.V.

  12. Detection of Salmonella enterica serovar Enteritidis (SE) Antibodies in Serum Using A Polystyrene Bead/SE Flagella Agglutination Assay

    USDA-ARS?s Scientific Manuscript database

    Serologic screening of flocks can be an important method to detect Salmonella enteritidis (SE) infections but can be labor intensive or lack specificity. Our goal was to develop a rapid agglutination assay using SE flagella adsorbed to polystyrene beads as a simple, relatively specific test to dete...

  13. Evaluation of the Alexon-Trend ProSpecT Campylobacter Microplate Assay

    PubMed Central

    Tolcin, Rita; LaSalvia, Margaret M.; Kirkley, Barbara A.; Vetter, Emily A.; Cockerill, Franklin R.; Procop, Gary W.

    2000-01-01

    We evaluated stool specimens known to contain or be free of Campylobacter by traditional culture, using the ProSpecT Campylobacter microplate assay (Alexon-Trend, Ramsey, Minn.). This rapid enzyme immunoassay for the detection of Campylobacter-specific antigens demonstrated 96% sensitivity and 99% specificity and is an acceptable alternative method of Campylobacter detection. PMID:11015419

  14. EDTA analysis on the Roche MODULAR analyser.

    PubMed

    Davidson, D F

    2007-05-01

    Patient specimens can be subject to subtle interference from cross contamination by liquid-based, potassium-containing EDTA anticoagulant, leading to misinterpretation of results. A rapid method for EDTA analysis to detect such contamination is described. An in-house EDTA assay on the Roche MODULAR analyser was assessed for accuracy and precision by comparison with an adjusted calcium difference measurement (atomic absorption and o-cresolphthalein complexone colorimetry). EDTA method versus adjusted calcium difference showed: slope = 1.038 (95% confidence interval [CI] 0.949-1.131); intercept = 0.073 (95% CI 0.018-0.132) mmol/L; r = 0.914; n = 94. However, inter-assay precision of the calcium difference method was estimated to be poorer (coefficient of variation 24.8% versus 3.4% for the automated colorimetric method at an EDTA concentration of 0.25 mmol/L). Unequivocal contamination was observed at an EDTA concentration of > or =0.2 mmol/L. The automated method showed positive interference from haemolysis and negative interference from oxalate. The method was unaffected by lipaemia (triglycerides <20 mmol/L), icterus (bilirubin <500 micromol/L), glucose (<100 mmol/L), iron (<100 micromol/L), and citrate, phosphate or fluoride (all <2.5 mmol/L). The automated colorimetric assay described is an accurate, precise and rapid (3 min) means of detecting EDTA contamination of unhaemolysed biochemistry specimens.

  15. A Rapid Survival Assay to Measure Drug-Induced Cytotoxicity and Cell Cycle Effects

    PubMed Central

    Valiathan, Chandni; McFaline, Jose L.

    2012-01-01

    We describe a rapid method to accurately measure the cytotoxicity of mammalian cells upon exposure to various drugs. Using this assay, we obtain survival data in a fraction of the time required to perform the traditional clonogenic survival assay, considered the gold standard. The dynamic range of the assay allows sensitivity measurements on a multi-log scale allowing better resolution of comparative sensitivities. Moreover, the results obtained contain additional information on cell cycle effects of the drug treatment. Cell survival is obtained from a quantitative comparison of proliferation between drug-treated and untreated cells. During the assay, cells are treated with a drug and, following a recovery period, allowed to proliferate in the presence of BrdU. Cells that synthesize DNA in the presence of bromodeoxyuridine (BrdU) exhibit quenched Hoechst fluorescence easily detected by flow cytometry; quenching is used to determine relative proliferation in treated versus untreated cells. Finally, the multi-well setup of this assay allows the simultaneous screening of multiple cell lines, multiple doses, or multiple drugs to accurately measure cell survival and cell cycle changes after drug treatment. PMID:22133811

  16. Development of flow-through and dip-stick immunoassays for screening of sulfonamide residues.

    PubMed

    Zhang, Hongyan; Zhang, Yan; Wang, Shuo

    2008-08-20

    Two formats of membrane-based competitive enzyme immunoassays (flow-through and dip-stick) have been developed for the screening of sulfonamide residues in pig muscle and milk. Membrane was coated with anti-sulfonamide antibody and a sulfonamide hapten D2-horseradish peroxidase (HRP) conjugant was used as the labeled antigen for competitive assay of sulfonamides. Visual detection limits of the flow-through or dip-stick assay were 1-5 microg L(-1) or 1-10 microg L(-1) in buffer for seven sulfonamides, respectively. Assay validation was performed using samples spiked with single sulfonamide, spiked samples were tested using the developed strip assays and results were compared with those obtained by a validated high-performance liquid chromatograph (HPLC) method. Results showed that the two strip assays were correlated well with HPLC, respectively. With assay times of 5 min (flow-through) and 15 min (dip-stick), these rapid tests could offer simple, rapid and cost-effective on-site screening tools to detect sulfonamides in pig muscle (flow-through or dip-stick) or milk (only dip-stick).

  17. Rapid detection of newly isolated Tembusu-related Flavivirus by reverse-transcription loop-mediated isothermal amplification assay

    PubMed Central

    2011-01-01

    Background From April 2010 to January 2011, a severe new viral disease had devastated most duck-farming regions in China. This disease affected not only laying ducks but also meat ducks, causing huge economic losses for the poultry industry. The objective of this study is to develop a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the detection of the new virus related to Tembusu-related Flavivirus. Results The RT-LAMP assay is very simple and rapid, and the amplification can be completed within 50 min under isothermal conditions at 63°C by a set of 6 primers targeting the E gene based on the sequences analysis of the newly isolated viruses and other closely related Flavivirus.The monitoring of gene amplification can also be visualized by using SYBR green I fluorescent dye. In addition, the RT-LAMP assay for newly isolated Tembusu-related Flavivirus showed higher sensitivity with an RNA detection-limit of 2 copies/μL compared with 190 copies/μL of the conventional RT-PCR method. The specificity was identified without cross reaction to other common avian pathogens. By screening a panel of clinical samples this method was more feasible in clinical settings and there was higher positive coincidence rate than conventional RT-PCR and virus isolation. Conclusion The RT-LAMP assay for newly isolated Tembusu-related Flavivirus is a valuable tool for the rapid and real-time detection not only in well-equipped laboratories but also in general conditions. PMID:22185513

  18. Development of a recombinase polymerase amplification assay for Vibrio parahaemolyticus detection with an internal amplification control.

    PubMed

    Yang, Huan-Lan; Wei, Shuang; Gooneratne, Ravi; Mutukumira, Anthony N; Ma, Xue-Jun; Tang, Shu-Ze; Wu, Xi-Yang

    2018-04-01

    A novel RPA-IAC assay using recombinase polymerase and an internal amplification control (IAC) for Vibrio parahaemolyticus detection was developed. Specific primers were designed based on the coding sequence for the toxR gene in V. parahaemolyticus. The recombinase polymerase amplification (RPA) reaction was conducted at a constant low temperature of 37 °C for 20 min. Assay specificity was validated by using 63 Vibrio strains and 10 non-Vibrio bacterial species. In addition, a competitive IAC was employed to avoid false-negative results, which co-amplified simultaneously with the target sequence. The sensitivity of the assay was determined as 3 × 10 3 CFU/mL, which is decidedly more sensitive than the established PCR method. This method was then used to test seafood samples that were collected from local markets. Seven out of 53 different raw seafoods were detected as V. parahaemolyticus-positive, which were consistent with those obtained using traditional culturing method and biochemical assay. This novel RPA-IAC assay provides a rapid, specific, sensitive, and more convenient detection method for V. parahaemolyticus.

  19. Rapid detection of multidrug-resistant Mycobacterium tuberculosis using the malachite green decolourisation assay

    PubMed Central

    Coban, Ahmet Yilmaz; Uzun, Meltem

    2013-01-01

    Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA) in detecting isoniazid (INH) and rifampicin (RIF) resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results. PMID:24402143

  20. Pyrosequencing-based validation of a simple cell-suspension polymerase chain reaction assay for Campylobacter with application of high-processivity polymerase and novel internal amplification controls for rapid and specific detection.

    PubMed

    Oakley, Brian B; Line, J Eric; Berrang, Mark E; Johnson, Jessica M; Buhr, R Jeff; Cox, Nelson A; Hiett, Kelli L; Seal, Bruce S

    2012-02-01

    Although Campylobacter is an important food-borne human pathogen, there remains a lack of molecular diagnostic assays that are simple to use, cost-effective, and provide rapid results in research, clinical, or regulatory laboratories. Of the numerous Campylobacter assays that do exist, to our knowledge none has been empirically tested for specificity using high-throughput sequencing. Here we demonstrate the power of next-generation sequencing to determine the specificity of a widely cited Campylobacter-specific polymerase chain reaction (PCR) assay and describe a rapid method for direct cell suspension PCR to quickly and easily screen samples for Campylobacter. We present a specific protocol which eliminates the need for time-consuming and expensive genomic DNA extractions and, using a high-processivity polymerase, demonstrate conclusive screening of samples in <1 h. Pyrosequencing results show the assay to be extremely (>99%) sensitive, and spike-back experiments demonstrated a detection threshold of <10(2) CFU mL(-1). Additionally, we present 2 newly designed broad-range bacterial primer sets targeting the 23S rRNA gene that have wide applicability as internal amplification controls. Empirical testing of putative taxon-specific assays using high-throughput sequencing is an important validation step that is now financially feasible for research, regulatory, or clinical applications. Published by Elsevier Inc.

  1. Evaluation of a newly developed quantitative heart-type fatty acid binding protein assay based on fluorescence immunochromatography using specific monoclonal antibodies.

    PubMed

    Kang, Keren; Wu, Peidian; Li, Wenmei; Tang, Shixing; Wang, Jihua; Luo, Xiaochun; Xie, Mingquan

    2015-01-01

    To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R(2) = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.

  2. A Fluorescence Quenching Assay Based on Molecular Beacon Formation through a Ligase Detection Reaction for Facile and Rapid Detection of Point Mutations.

    PubMed

    Sawamura, Kensuke; Hashimoto, Masahiko

    2017-01-01

    A fluorescence quenching assay based on a ligase detection reaction was developed for facile and rapid detection of point mutations present in a mixed population of non-variant DNA. If the test DNA carried a targeted mutation, then the two allele-specific primers were ligated to form a molecular beacon resulting in the expected fluorescence quenching signatures. Using this method, we successfully detected as low as 5% mutant DNA in a mixture of wild-type DNA (t test at 99% confidence level).

  3. Comparison of Xpert Flu rapid nucleic acid testing with rapid antigen testing for the diagnosis of influenza A and B.

    PubMed

    DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A

    2012-12-01

    Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Development of real-time recombinase polymerase amplification assay for rapid and sensitive detection of canine parvovirus 2.

    PubMed

    Geng, Yunyun; Wang, Jianchang; Liu, Libing; Lu, Yan; Tan, Ke; Chang, Yan-Zhong

    2017-11-06

    Canine parvovirus 2, a linear single-stranded DNA virus belonging to the genus Parvovirus within the family Parvoviridae, is a highly contagious pathogen of domestic dogs and several wild canidae species. Early detection of canine parvovirus (CPV-2) is crucial to initiating appropriate outbreak control strategies. Recombinase polymerase amplification (RPA), a novel isothermal gene amplification technique, has been developed for the molecular detection of diverse pathogens. In this study, a real-time RPA assay was developed for the detection of CPV-2 using primers and an exo probe targeting the CPV-2 nucleocapsid protein gene. The real-time RPA assay was performed successfully at 38 °C, and the results were obtained within 4-12 min for 10 5 -10 1 molecules of template DNA. The assay only detected CPV-2, and did not show cross-detection of other viral pathogens, demonstrating a high level of specificity. The analytical sensitivity of the real-time RPA was 10 1 copies/reaction of a standard DNA template, which was 10 times more sensitive than the common RPA method. The clinical sensitivity of the real-time RPA assay matched 100% (n = 91) to the real-time PCR results. The real-time RPA assay is a simple, rapid, reliable and affordable method that can potentially be applied for the detection of CPV-2 in the research laboratory and point-of-care diagnosis.

  5. Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute Scrub Typhus infection.

    PubMed

    Paris, Daniel H; Blacksell, Stuart D; Nawtaisong, Pruksa; Jenjaroen, Kemajittra; Teeraratkul, Achara; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Kantipong, Pacharee; Day, Nicholas P J

    2011-09-01

    There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.

  6. Rapid Screening Assay for the Detection of Nivalenol and Deoxynivalenol using Monoclonal Antibody and Surface Plasmon Resonance

    USDA-ARS?s Scientific Manuscript database

    Nivalenol (NIV) and Deoxynivalenol (DON) are trichothecene mycotoxins produced by Fusarium spp that contaminate mainly cereal crops, such as wheat, barley, and maize. These mycotoxins are serious health hazards to human and domestic animals. The study reports a rapid screening method of NIV and DO...

  7. Rapid Estimation of Tocopherol Content in Linseed and Sunflower Oils-Reactivity and Assay.

    PubMed

    Prevc, Tjaša; Levart, Alenka; Cigić, Irena Kralj; Salobir, Janez; Ulrih, Nataša Poklar; Cigić, Blaž

    2015-08-13

    The reactivity of tocopherols with 2,2-diphenyl-1-picrylhydrazyl (DPPH) was studied in model systems in order to establish a method for quantifying vitamin E in plant oils. The method was optimized with respect to solvent composition of the assay medium, which has a large influence on the course of reaction of tocopherols with DPPH. The rate of reaction of α-tocopherol with DPPH is higher than that of γ-tocopherol in both protic and aprotic solvents. In ethyl acetate, routinely applied for the analysis of antioxidant potential (AOP) of plant oils, reactions of tocopherols with DPPH are slower and concentration of tocopherols in the assay has a large influence on their molar reactivity. In 2-propanol, however, two electrons are exchanged for both α- and γ-tocopherols, independent of their concentration. 2-propanol is not toxic and is fully compatible with polypropylene labware. The chromatographically determined content of tocopherols and their molar reactivity in the DPPH assay reveal that only tocopherols contribute to the AOP of sunflower oil, whereas the contribution of tocopherols to the AOP of linseed oil is 75%. The DPPH assay in 2-propanol can be applied for rapid and cheap estimation of vitamin E content in plant oils where tocopherols are major antioxidants.

  8. Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea

    PubMed Central

    Kurosaki, Yohei; Magassouba, N’Faly; Oloniniyi, Olamide K.; Cherif, Mahamoud S.; Sakabe, Saori; Takada, Ayato; Hirayama, Kenji; Yasuda, Jiro

    2016-01-01

    Given the current absence of specific drugs or vaccines for Ebola virus disease (EVD), rapid, sensitive, and reliable diagnostic methods are required to stem the transmission chain of the disease. We have developed a rapid detection assay for Zaire ebolavirus based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and coupled with a novel portable isothermal amplification and detection platform. The RT-LAMP assay is based on primer sets that target the untranscribed trailer region or nucleoprotein coding region of the viral RNA. The test could specifically detect viral RNAs of Central and West African Ebola virus strains within 15 minutes with no cross-reactivity to other hemorrhagic fever viruses and arboviruses, which cause febrile disease. The assay was evaluated using a total of 100 clinical specimens (serum, n = 44; oral swab, n = 56) collected from suspected EVD cases in Guinea. The specificity of this diagnostic test was 100% for both primer sets, while the sensitivity was 100% and 97.9% for the trailer and nucleoprotein primer sets, respectively, compared with a reference standard RT-PCR test. These observations suggest that our diagnostic assay is useful for identifying EVD cases, especially in the field or in settings with insufficient infrastructure. PMID:26900929

  9. Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea.

    PubMed

    Kurosaki, Yohei; Magassouba, N'Faly; Oloniniyi, Olamide K; Cherif, Mahamoud S; Sakabe, Saori; Takada, Ayato; Hirayama, Kenji; Yasuda, Jiro

    2016-02-01

    Given the current absence of specific drugs or vaccines for Ebola virus disease (EVD), rapid, sensitive, and reliable diagnostic methods are required to stem the transmission chain of the disease. We have developed a rapid detection assay for Zaire ebolavirus based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and coupled with a novel portable isothermal amplification and detection platform. The RT-LAMP assay is based on primer sets that target the untranscribed trailer region or nucleoprotein coding region of the viral RNA. The test could specifically detect viral RNAs of Central and West African Ebola virus strains within 15 minutes with no cross-reactivity to other hemorrhagic fever viruses and arboviruses, which cause febrile disease. The assay was evaluated using a total of 100 clinical specimens (serum, n = 44; oral swab, n = 56) collected from suspected EVD cases in Guinea. The specificity of this diagnostic test was 100% for both primer sets, while the sensitivity was 100% and 97.9% for the trailer and nucleoprotein primer sets, respectively, compared with a reference standard RT-PCR test. These observations suggest that our diagnostic assay is useful for identifying EVD cases, especially in the field or in settings with insufficient infrastructure.

  10. Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.

    PubMed

    Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei

    2012-06-01

    The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.

  11. Direct Application of the INNO-LiPA Rif.TB Line-Probe Assay for Rapid Identification of Mycobacterium tuberculosis Complex Strains and Detection of Rifampin Resistance in 360 Smear-Positive Respiratory Specimens from an Area of High Incidence of Multidrug-Resistant Tuberculosis

    PubMed Central

    Viveiros, Miguel; Leandro, Clara; Rodrigues, Liliana; Almeida, Josefina; Bettencourt, Rosário; Couto, Isabel; Carrilho, Lurdes; Diogo, José; Fonseca, Ana; Lito, Luís; Lopes, João; Pacheco, Teresa; Pessanha, Mariana; Quirim, Judite; Sancho, Luísa; Salfinger, Max; Amaral, Leonard

    2005-01-01

    The INNO-LiPA Rif.TB assay for the identification of Mycobacterium tuberculosis complex strains and the detection of rifampin (RIF) resistance has been evaluated with 360 smear-positive respiratory specimens from an area of high incidence of multidrug-resistant tuberculosis (MDR-TB). The sensitivity when compared to conventional identification/culture methods was 82.2%, and the specificity was 66.7%; the sensitivity and specificity were 100.0% and 96.9%, respectively, for the detection of RIF resistance. This assay has the potential to provide rapid information that is essential for the effective management of MDR-TB. PMID:16145166

  12. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    PubMed

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  13. Isothermal Method of a Recombinase Polymerase Amplification Assay for the Detection of Most Common High-Risk Human Papillomavirus Type 16 and Type 18 DNA.

    PubMed

    Ma, Biao; Fang, Jiehong; Wang, Ye; He, Haizhen; Dai, Mingyan; Lin, Wei; Su, Wei; Zhang, Mingzhou

    2017-01-01

    Cervical cancer is a common gynecologic malignant tumor and has a great impact on women's health. Human papillomavirus (HPV) is implicated in cervical cancer and precancerous lesions and the two are possibly two stages of disease progression. With the technological development of molecular biology and epidemiology, detection and treatment of HPV has become an important means to prevent cervical cancer. Here we present a novel, rapid, sensitive and specific isothermal method of recombinase polymerase amplification (RPA), which is established to detect the two most common high-risk human papillomavirus type 16 and type 18 DNA. In this study, we evaluate the efficacy of the RPA assay, incubating clinical specimens of HPV16 and HPV18 using plasmids standard. It operates at constant low temperature without the thermal instrumentation for incubation. The products can be detected via agarose gel electrophoresis assay, reverse dot blot assay, and quantitative real-time assay with SYBR Green I. We assess the diagnostic performance of the RPA assay for detecting of HPV16 and HPV18 in 335 clinical samples from patients suspected of cervical cancer. The results revealed no cross-reaction with other HPV genotypes and the RPA assay achieve a sensitivity of 100 copies. Compared with TaqMan qPCR, the RPA technique achieves exponential amplification with no need for pretreatment of sample DNA at 37°C for 20 minutes, which reveals more satisfactory performance. The agreement between the RPA and qPCR assays was 97.6% (κ = 0.89) for HPV16 positivity and 98.5% (κ = 0.81) for HPV18 positivity, indicating very good correlation between both tests. Importantly, the RPA assay was demonstrated to be a useful and powerful method for detection of HPV virus, which therefore may serve as a valuable tool for rapid diagnosis of HPV infection in both commercial and clinical applications.

  14. High throughput screening technologies for ion channels

    PubMed Central

    Yu, Hai-bo; Li, Min; Wang, Wei-ping; Wang, Xiao-liang

    2016-01-01

    Ion channels are involved in a variety of fundamental physiological processes, and their malfunction causes numerous human diseases. Therefore, ion channels represent a class of attractive drug targets and a class of important off-targets for in vitro pharmacological profiling. In the past decades, the rapid progress in developing functional assays and instrumentation has enabled high throughput screening (HTS) campaigns on an expanding list of channel types. Chronologically, HTS methods for ion channels include the ligand binding assay, flux-based assay, fluorescence-based assay, and automated electrophysiological assay. In this review we summarize the current HTS technologies for different ion channel classes and their applications. PMID:26657056

  15. Rapid quantitative analysis of 8-iso-prostaglandin-F(2alpha) using liquid chromatography-tandem mass spectrometry and comparison with an enzyme immunoassay method.

    PubMed

    Dahl, Jeffrey H; van Breemen, Richard B

    2010-09-15

    A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed for the measurement of urinary 8-iso-prostaglandin F(2alpha) (8-iso-PGF(2alpha)), a biomarker of lipid peroxidation. Because urine contains numerous F(2) prostaglandin isomers, each with identical mass and similar mass spectrometric fragmentation patterns, chromatographic separation of 8-iso-PGF(2alpha) from its isomers is necessary for its quantitative analysis using MS/MS. We were able to achieve this separation using an isocratic LC method with a run time of less than 9min, which is at least threefold faster than previous methods, while maintaining sensitivity, accuracy, precision, and reliability. The limits of detection and quantitation were 53 and 178pg/ml urine, respectively. We compared our method with a commercially available affinity purification and enzyme immunoassay kit and found both assays to be in agreement. Despite the high sensitivity of the enzyme immunoassay method, it is more expensive and has a narrower dynamic range than LC-MS/MS. Our method was optimized for rapid measurement of 8-iso-PGF(2alpha) in urine, and it is ideally suited for clinical sample analysis. 2010 Elsevier Inc. All rights reserved.

  16. A new application of a sodium deoxycholate-propidium monoazide-quantitative PCR assay for rapid and sensitive detection of viable Cronobacter sakazakii in powdered infant formula.

    PubMed

    Zhou, Baoqing; Chen, Bolu; Wu, Xin; Li, Fan; Yu, Pei; Aguilar, Zoraida P; Wei, Hua; Xu, Hengyi

    2016-12-01

    A rapid, reliable, and sensitive method for the detection of Cronobacter sakazakii, a common foodborne pathogen that may cause serious neonatal disease, has been developed. In this study, a rapid real-time quantitative PCR (qPCR) assay combined with sodium deoxycholate (SD) and propidium monoazide (PMA) was developed to detect C. sakazakii contamination in powdered infant formula (PIF). This method could eliminate the interference from dead or injured bacteria. Optimization studies indicated that SD and PMA at 0.08% (wt/vol) and 5µg/mL, respectively, were the most appropriate. In addition, qPCR, PMA-qPCR, SD-PMA-qPCR, and plate count assays were used to account for the number of viable bacteria in cell suspensions that were exposed to a 55°C water bath at different length of time. As a result, the viable number by PMA-qPCR showed significantly higher than of the number from SD-PMA-qPCR or plate counts. The number of viable bacteria was consistent between SD-PMA-qPCR and traditional plate counts, which indicated that SD treatment could eliminate the interference from dead or injured cells. Using the optimized parameters, the limit of detection with the SD-PMA-qPCR assay was 3.3×10 2 cfu/mL and 4.4×10 2 cfu/g in pure culture and in spiked PIF, respectively. A similar detection limit of 5.6×10 2 cfu/g was obtained in the presence of the Staphylococcus aureus (10 7 cfu/mL). The combined SD-PMA-qPCR assay holds promise for the rapid detection of viable C. sakazakii in PIF. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Rapid diagnosis of tuberculosis in dromedary camel (Camelus dromedarius) using lateral flow assay-based kit.

    PubMed

    Ranjan, Rakesh; Narnaware, Shirish D; Nath, Kashi; Sawal, R K; Patil, N V

    2018-04-01

    Accurate early antemortem diagnosis of tuberculosis in dromedary camels is difficult due to the lack of reliable diagnostic test. The present study aimed to evaluate a lateral flow assay-based kit (rapid assay kit) in tuberculosis diagnosis that employs immuno-chromatographic detection of antibodies in serum, plasma, or whole blood. In a dromedary camel herd comprising 337 animals located at Bikaner, Rajasthan, India, 50 adult weak camels (11 males and 39 females) were tested by applying a single intradermal tuberculin test (SIDT) and rapid assay kit. A total of 14 animals (2 males, 12 females) were found positive in rapid assay. In SIDT, four animals revealed a positive reaction in the neck region and seven animals in the tail base. Another male animal was found SIDT positive but negative in rapid assay; it died after 12 months. Nine rapid assay positive animals died asymptomatically in 1- to 11-month period revealing postmortem tuberculosis lesions that were confirmed by Ziehl-Neelsen staining and histopathology. No tuberculous lesion was evident in the animal found positive in SIDT alone. Results of the present study indicated that serological tests like rapid assay kit can serve as a reliable test for antemortem diagnosis of tuberculosis in dromedary camel.

  18. Rapid screening method for male DNA by using the loop-mediated isothermal amplification assay.

    PubMed

    Kitamura, Masashi; Kubo, Seiji; Tanaka, Jin; Adachi, Tatsushi

    2017-08-12

    Screening for male-derived biological material from collected samples plays an important role in criminal investigations, especially those involving sexual assaults. We have developed a loop-mediated isothermal amplification (LAMP) assay targeting multi-repeat sequences of the Y chromosome for detecting male DNA. Successful amplification occurred with 0.5 ng of male DNA under isothermal conditions of 61 to 67 °C, but no amplification occurred with up to 10 ng of female DNA. Under the optimized conditions, the LAMP reaction initiated amplification within 10 min and amplified for 20 min. The LAMP reaction was sensitive at levels as low as 1-pg male DNA, and a quantitative LAMP assay could be developed because of the strong correlation between the reaction time and the amount of template DNA in the range of 10 pg to 10 ng. Furthermore, to apply the LAMP assay to on-site screening for male-derived samples, we evaluated a protocol using a simple DNA extraction method and a colorimetric intercalating dye that allows detection of the LAMP reaction by evaluating the change in color of the solution. Using this protocol, samples of male-derived blood and saliva stains were processed in approximately 30 min from DNA extraction to detection. Because our protocol does not require much hands-on time or special equipment, this LAMP assay promises to become a rapid and simple screening method for male-derived samples in forensic investigations.

  19. Evaluation of a QuECHERS-like extraction approach for the determination of PBDEs in mussels by immuno-assay-based screening methods

    USDA-ARS?s Scientific Manuscript database

    A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. A simple sample preparation in conjunction with a rapid screening method possesses the desired c...

  20. Protocol for the use of a rapid real-time PCR method for the detection of HIV-1 proviral DNA using double-stranded primer.

    PubMed

    Pau, Chou-Pong; Wells, Susan K; Granade, Timothy C

    2012-01-01

    This chapter describes a real-time PCR method for the detection of HIV-1 proviral DNA in whole blood samples using a novel double-stranded primer system. The assay utilizes a simple commercially available DNA extraction method and a rapid and easy-to-perform real-time PCR protocol to consistently detect a minimum of four copies of HIV-1 group M proviral DNA in as little as 90 min after sample (whole blood) collection. Co-amplification of the human RNase P gene serves as an internal control to monitor the efficiency of both the DNA extraction and amplification. Once the assay is validated properly, it may be suitable as an alternative confirmation test for HIV-1 infections in a variety of HIV testing venues including the mother-to-child transmission testing sites, clinics, and diagnostic testing centers.

  1. NEW TARGET AND CONTROL ASSAYS FOR QUANTITATIVE POLYMERASE CHAIN REACTION (QPCR) ANALYSIS OF ENTEROCOCCI IN WATER

    EPA Science Inventory

    Enterococci are frequently monitored in water samples as indicators of fecal pollution. Attention is now shifting from culture based methods for enumerating these organisms to more rapid molecular methods such as QPCR. Accurate quantitative analyses by this method requires highly...

  2. Rapid Determination of Lymphogranuloma Venereum Serovars of Chlamydia trachomatis by Quantitative High-Resolution Melt Analysis (HRMA)

    PubMed Central

    Stevens, Matthew P.; Garland, Suzanne M.; Zaia, Angelo M.; Tabrizi, Sepehr N.

    2012-01-01

    A quantitative high-resolution melt analysis assay was developed to differentiate lymphogranuloma venereum-causing serovars of Chlamydia trachomatis (L1 to L3) from other C. trachomatis serovars (D to K). The detection limit of this assay is approximately 10 copies per reaction, comparable to the limits of other quantitative-PCR-based methods. PMID:22933594

  3. Rapid screening of toxigenic vibrio cholerae O1 strains from south Iran by PCR-ELISA.

    PubMed

    Mousavi, Seyed Latif; Nazarian, Shahram; Amani, Jafar; Rahgerdi, Ahmad Karimi

    2008-01-01

    The ability to sensitively detect Vibrio cholera with PCR-ELISA method represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen. The aim of this research is to evaluate the suitability of a PCR-enzyme-linked immunosorbent assay for sensitive and rapid detection of V. cholera O1. The 398-bp sequence of a gene that codes for the cholera toxin B subunit was amplified by PCR. The digoxigenin-labeled amplified products were coated on microplates and detected by ELISA. The PCR product was also hybridized with biotin labelled probe and detected by ELISA using streptavidin. The specificity of the PCR was determined using 10 bacterial strains and 50 samples from south Iran. The detection limit was 0.5 pg of the genomic DNA and five bacterial cells. Adaptation of PCR into PCR-ELISA assay format facilitates specific and sensitive detection and diagnosis of human cholera disease. We conclude that this PCR-ELISA is a diagnostic method that specifically detects toxin genes in V. cholera O1 strains. It is more rapid and less cumbersome than other diagnostic methods for detection of toxicity in these strains.

  4. Screening tests for the rapid detection of diarrhetic shellfish toxins in Washington State.

    PubMed

    Eberhart, Bich-Thuy L; Moore, Leslie K; Harrington, Neil; Adams, Nicolaus G; Borchert, Jerry; Trainer, Vera L

    2013-09-30

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test "pre-harvest" shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer's recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters.

  5. Screening Tests for the Rapid Detection of Diarrhetic Shellfish Toxins in Washington State

    PubMed Central

    Eberhart, Bich-Thuy L.; Moore, Leslie K.; Harrington, Neil; Adams, Nicolaus G.; Borchert, Jerry; Trainer, Vera L.

    2013-01-01

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test “pre-harvest” shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer’s recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters. PMID:24084788

  6. Diagnostic value of animal-side antibody assays for rapid detection of Mycobacterium bovis or Mycobacterium microti infection in South American camelids.

    PubMed

    Lyashchenko, Konstantin P; Greenwald, Rena; Esfandiari, Javan; Rhodes, Shelley; Dean, Gillian; de la Rua-Domenech, Ricardo; Meylan, Mireille; Vordermeier, H Martin; Zanolari, Patrik

    2011-12-01

    Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB.

  7. Diagnostic Value of Animal-Side Antibody Assays for Rapid Detection of Mycobacterium bovis or Mycobacterium microti Infection in South American Camelids▿

    PubMed Central

    Lyashchenko, Konstantin P.; Greenwald, Rena; Esfandiari, Javan; Rhodes, Shelley; Dean, Gillian; de la Rua-Domenech, Ricardo; Meylan, Mireille; Vordermeier, HMartin; Zanolari, Patrik

    2011-01-01

    Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB. PMID:22012976

  8. Development of simple and rapid assay to detect viral RNA of tick-borne encephalitis virus by reverse transcription-loop-mediated isothermal amplification.

    PubMed

    Hayasaka, Daisuke; Aoki, Kotaro; Morita, Kouichi

    2013-03-04

    Tick-borne encephalitis virus (TBEV) is a causative agent of acute central nervous system disease in humans. It has three subtypes, far eastern (FE), Siberian (Sib) and European (Eu) subtypes, which are distributed over a wide area of Europe and Asia. The objective of this study was to develop a simple and rapid assay for the detection of TBEV RNA by using reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) method that can differentiate the three subtypes of TBEV and can be used for clinical diagnosis and epidemiological study. Primers for TBEV-specific and subtype-specific RT-LAMP assay were designed to target the consensus sequence in NS1 of all subtypes and the consensus sequence in the E gene of each subtype, respectiveluy. In vitro transcribed RNA of Oshima strain that belongs to FE subtype was serially diluted and used to examine the sensitivity of the assay. Cross-reactivity of subtype-specific RT-LAMP assay was tested by using the RNA of Oshima and Sofjin (FE), IR-99 (Sib) and Hochosterwitz (Eu) strains. RNA extracted from the mixtures of TBEV and ticks, and of TBEV and human blood, and the mouse tissues infected with TBEV, were evaluated in the assay. Positive amplification was observed by real-time monitoring of turbidity and by visual detection of color change. The sensitivity of TBEV-specific RT-LAMP assay was 102 copies of target RNA per reaction volume. FE-specific RT-LAMP assay amplified viral genes of Oshima and Sofjin strains but not of IR-99 and Hochosterwitz strains, and of Japanese encephalitis virus. RT-LAMP assay for Sib and for Eu specifically amplified viral genes of IR-99 and Hochosterwitz strains, respectively. We also showed that tick or human blood extract did not inhibit the amplification of viral gene during the assay. Furthermore, we confirmed that the TBEV RT-LAMP could detect virus RNA from peripheral and central nervous system tissues of laboratory mice infected with TBEV. TBEV RT-LAMP assay offers a sensitive, specific, rapid and easy-to-handle method for the detection of TBEV RNA in tick samples and this may be applied in the clinical samples collected from TBE-suspected patients.

  9. A rapid and ultrasensitive SERRS assay for histidine and tyrosine based on azo coupling.

    PubMed

    Sui, Huimin; Wang, Yue; Yu, Zhi; Cong, Qian; Han, Xiao Xia; Zhao, Bing

    2016-10-01

    A simple and highly sensitive surface-enhanced resonance Raman scattering (SERRS)-based approach coupled with azo coupling reaction has been put forward for quantitative analysis of histidine and tyrosine. The SERRS-based assay is simple and rapid by mixing the azo reaction products with silver nanoparticles (AgNPs) for measurements within 2min. The limits of detection (LODs) of the method are as low as 4.33×10(-11) and 8.80×10(-11)M for histidine and tyrosine, respectively. Moreover, the SERRS fingerprint information specific to corresponding amino acids guarantees the selective detection for the target histidine and tyrosine. The results from serum indicated the potential application of the proposed approach into biological samples. Compared with the methods ever reported, the main advantages of this methodology are simpleness, rapidity without time-consuming separation or pretreatment steps, high sensitivity, selectivity and the potential for determination of other molecules containing imidazole or phenol groups. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. High resolution melting analytical platform for rapid prenatal and postnatal diagnosis of β-thalassemia common among Southeast Asian population.

    PubMed

    Prajantasen, Thanet; Fucharoen, Supan; Fucharoen, Goonnapa

    2015-02-20

    High resolution melting (HRM) analysis is a powerful technology for scanning sequence alteration. We have applied this HRM assay to screen common β-thalassemia mutations found among Southeast Asian population. Known DNA samples with 8 common mutations were used in initial development of the methods including -28 A-G, codon 17 A-T, IVSI-1G-T, IVSI-5G-C, codon 26G-A (Hb E), codons 41/42 -TTCT, codons 71/72+A and IVSII-654 C-T. Further validation was done on 60 postnatal and 6 prenatal diagnoses of β-thalassemia. Each mutation has specific HRM profile which could be used in rapid screening. Apart from those with DNA deletions, the results of HRM assay matched 100% with those of routine diagnosis made by routine allele specific PCR. In addition, the HRM assay could initially recognize three unknown mutations including a hitherto un-described one in Thai population. The established HRM assay should prove useful for rapid and high throughput platform for screening and prenatal diagnosis of β-thalassemia common in the region. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Development of in vitro and in vivo rabies virus neutralization assays based on a high-titer pseudovirus system

    PubMed Central

    Nie, Jianhui; Wu, Xiaohong; Ma, Jian; Cao, Shouchun; Huang, Weijin; Liu, Qiang; Li, Xuguang; Li, Yuhua; Wang, Youchun

    2017-01-01

    Pseudoviruses are useful virological tools because of their safety and versatility; however the low titer of these viruses substantially limits their wider applications. We developed a highly efficient pseudovirus production system capable of yielding 100 times more rabies pseudovirus than the traditional method. Employing the high-titer pseudoviruses, we have developed robust in vitro and in vivo neutralization assays for the evaluation of rabies vaccine, which traditionally relies on live-virus based assays. Compared with current rapid fluorescent focus inhibition test (RFFIT), our in vitro pseudovirus-based neutralization assay (PBNA) is much less labor-intensive while demonstrating better reproducibility. Moreover, the in vivo PBNA assay was also found to be superior to the live virus based assay. Following intravenous administration, the pseudovirus effectively infected the mice, with dynamic viral distributions being sequentially observed in spleen, liver and brain. Furthermore, data from in vivo PBNA showed great agreement with those generated from the live virus model but with the experimental time significantly reduced from 2 weeks to 3 days. Taken together, the effective pseudovirus production system facilitated the development of novel PBNA assays which could replace live virus-based traditional assays due to its safety, rapidity, reproducibility and high throughput capacity. PMID:28218278

  12. Rapid and specific detection of Salmonella in water samples using real-time PCR and High Resolution Melt (HRM) curve analysis.

    PubMed

    van Blerk, G N; Leibach, L; Mabunda, A; Chapman, A; Louw, D

    2011-01-01

    A real-time PCR assay combined with a pre-enrichment step for the specific and rapid detection of Salmonella in water samples is described. Following amplification of the invA gene target, High Resolution Melt (HRM) curve analysis was used to discriminate between products formed and to positively identify invA amplification. The real-time PCR assay was evaluated for specificity and sensitivity. The assay displayed 100% specificity for Salmonella and combined with a 16-18 h non-selective pre-enrichment step, the assay proved to be highly sensitive with a detection limit of 1.0 CFU/ml for surface water samples. The detection assay also demonstrated a high intra-run and inter-run repeatability with very little variation in invA amplicon melting temperature. When applied to water samples received routinely by the laboratory, the assay showed the presence of Salmonella in particularly surface water and treated effluent samples. Using the HRM based assay, the time required for Salmonella detection was drastically shortened to less than 24 h compared to several days when using standard culturing methods. This assay provides a useful tool for routine water quality monitoring as well as for quick screening during disease outbreaks.

  13. Application of Pyrosequencing® in Food Biodefense.

    PubMed

    Amoako, Kingsley Kwaku

    2015-01-01

    The perpetration of a bioterrorism attack poses a significant risk for public health with potential socioeconomic consequences. It is imperative that we possess reliable assays for the rapid and accurate identification of biothreat agents to make rapid risk-informed decisions on emergency response. The development of advanced methodologies for the detection of biothreat agents has been evolving rapidly since the release of the anthrax spores in the mail in 2001, and recent advances in detection and identification techniques could prove to be an essential component in the defense against biological attacks. Sequence-based approaches such as Pyrosequencing(®), which has the capability to determine short DNA stretches in real time using biotinylated PCR amplicons, have potential biodefense applications. Using markers from the virulence plasmids and chromosomal regions, my laboratory has demonstrated the power of this technology in the rapid, specific, and sensitive detection of B. anthracis spores and Yersinia pestis in food. These are the first applications for the detection of the two organisms in food. Furthermore, my lab has developed a rapid assay to characterize the antimicrobial resistance (AMR) gene profiles for Y. pestis using Pyrosequencing. Pyrosequencing is completed in about 60 min (following PCR amplification) and yields accurate and reliable results with an added layer of confidence, thus enabling rapid risk-informed decisions to be made. A typical run yields 40-84 bp reads with 94-100 % identity to the expected sequence. It also provides a rapid method for determining the AMR profile as compared to the conventional plate method which takes several days. The method described is proposed as a novel detection system for potential application in food biodefense.

  14. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    PubMed

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  15. Advances in Assays and Analytical Approaches for Botulinum Toxin Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grate, Jay W.; Ozanich, Richard M.; Warner, Marvin G.

    2010-08-04

    Methods to detect botulinum toxin, the most poisonous substance known, are reviewed. Current assays are being developed with two main objectives in mind: 1) to obtain sufficiently low detection limits to replace the mouse bioassay with an in vitro assay, and 2) to develop rapid assays for screening purposes that are as sensitive as possible while requiring an hour or less to process the sample an obtain the result. This review emphasizes the diverse analytical approaches and devices that have been developed over the last decade, while also briefly reviewing representative older immunoassays to provide background and context.

  16. Rapid and amplification-free detection of fish pathogens by utilizing a molecular beacon-based microfluidic system.

    PubMed

    Su, Yi-Chih; Wang, Chih-Hung; Chang, Wen-Hsin; Chen, Tzong-Yueh; Lee, Gwo-Bin

    2015-01-15

    Nervous necrosis virus (NNV) and iridovirus are highly infectious pathogens that can cause lethal diseases in various species of fish. These infectious diseases have no effective treatments and the mortality rate is over 80%, which could cause dramatic economic losses in the aquaculture industry. Conventional diagnostic methods of NNV or iridovirus infected fishes, such as virus culture, enzyme-linked immunosorbent assays and nucleic acid assays usually require time-consuming and complex procedures performed by specialized technicians with delicate laboratory facilities. Rapid, simple, accurate and on-site detection of NNV and iridovirus infections would enable timely preventive measures such as immediate sacrifice of infected fishes, and is therefore critically needed for the aquaculture industry. In this study, a microfluidic-based assay that employ magnetic beads conjugated with viral deoxyribonucleic acid (DNA) capturing probes and fluorescent DNA molecular beacons were developed to rapidly detect NNV and iridovirus. Importantly, this new assay was realized in an integrated microfluidic system with a custom-made control system. With this approach, direct and automated NNV and iridovirus detection from infected fishes can be achieved in less than 30 min. Therefore, this molecular-beacon based microfluidic system presents a potentially promising tool for rapid diagnosis of fish pathogens in the field in the future. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Rapid detection of carbapenemase-producing Klebsiella pneumoniae strains derived from blood cultures by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS).

    PubMed

    Sakarikou, Christina; Ciotti, Marco; Dolfa, Camilla; Angeletti, Silvia; Favalli, Cartesio

    2017-03-08

    Carbapenemase-producing Enterobacteriaceae (CPE), particularly carbapenemase-producing Klebsiella pneumoniae isolates, are important causative agents of nosocomial infections associated with significant mortality rates mostly in critical wards. The rapid detection and typing of these strains is critical either for surveillance purposes and to prevent outbreaks and optimize antibiotic therapy. In this study, the MALDI-TOF MS method was used to detect rapidly these isolates from blood cultures (BCs) and to obtain proteomic profiles enable to discriminate between carbapenemase-producing and non-carbapenemase-producing strains. Fifty-five K. pneumoniae strains were tested. Identification and carbapenemase-production detection assay using Ertapenem were performed both from bacterial pellets extracted directly from BCs flasks and from subcultures of these strains. For all isolates, a complete antimicrobial susceptibility testing and a genotypic characterization were performed. We found 100% agreement between the carbapenemase-producing profile generated by MALDI TOF MS and that obtained using conventional methods. The assay detected and discriminated different carbapenemase-producing K. pneumoniae isolates within 30 min to 3 h after incubation with Ertapenem. MALDI-TOF MS is a promising, rapid and economical method for the detection of carbapenemase-producing K. pneumoniae strains that could be successfully introduced into the routine diagnostic workflow of clinical microbiology laboratories.

  18. Comparison of Real-Time PCR and Conventional Biochemical Methods for Identification of Staphylococcus lugdunensis▿

    PubMed Central

    Pinsky, Benjamin A.; Samson, Divinia; Ghafghaichi, Laleh; Baron, Ellen J.; Banaei, Niaz

    2009-01-01

    Staphylococcus lugdunensis is an aggressive, virulent member of the coagulase-negative staphylococci (CoNS) that is responsible for severe, rapidly progressive skin and soft tissue infections and native valve endocarditis. To facilitate prompt identification and appropriate therapy, we describe here a rapid and robust multiplex real-time PCR assay that is able to definitively distinguish S. lugdunensis from other staphylococci. Using melting curve analysis, the assay also identifies Staphylococcus aureus and CoNS other than S. lugdunensis and determines MecA-dependent resistance to methicillin (meticillin). When applied to a panel of well-characterized staphylococcal reference strains, as well as 165 clinical isolates previously identified by conventional methods, the assay was both sensitive and specific for S. lugdunensis, correctly identifying the reference strain and all 47 S. lugdunensis isolates without inappropriate amplification of other staphylococci. Furthermore, rapid biochemical identification using the WEE-TAB system to detect ornithine decarboxylase activity was found to be unsuitable as an alternative to PCR identification, displaying just 31% sensitivity and 77% specificity when tested on a subset (90 isolates) of the clinical strains. We therefore propose that this simple, accurate PCR approach will allow for the routine and timely identification of S. lugdunensis in the clinical microbiology laboratory. PMID:19741081

  19. Development of a polymerase chain reaction-based assay for the detection of Alternaria fungal contamination in food products.

    PubMed

    Zur, G; Hallerman, E M; Sharf, R; Kashi, Y

    1999-10-01

    Alternaria sp. are important fungal contaminants of vegetable, fruit, and grain products, including Alternaria alternata, a contaminant of tomato products. To date, the Howard method, based on microscopic observation of fungal filaments, has been the standard examination for inspection of tomato products. We report development of a polymerase chain reaction (PCR)-based method for detection of Alternaria DNA. PCR primers were designed to anneal to the internal transcribed regions ITS1 and ITS2 of the 5.8S rRNA gene of Alternaria but not to other microbial or tomato DNA. We demonstrate use of the PCR assay to detect Alternaria DNA in experimentally infested and commercially obtained tomato sauce and tomato powder. Use of the PCR method offers a rapid and sensitive assay for the presence of Alternaria DNA in tomato products. The apparent breakdown of DNA in tomato sauce may limit the utility of the assay to freshly prepared products. The assay for tomato powder is not affected by storage time.

  20. Rapid and Sensitive Detection of Pseudomonas aeruginosa in Chlorinated Water and Aerosols targeting gyrB gene using Real-time PCR

    PubMed Central

    Lee, Chang Soo; Wetzel, Kaedra; Buckley, Timothy; Wozniak, Daniel; Lee, Jiyoung

    2011-01-01

    Aims For the rapid detection of P. aeruginosa from chlorinated water and aerosols, gyrB gene-based real-time PCR assay was developed and investigated. Methods and Results Two novel primer sets (pa722F/746MGB/899R and pa722F/746MGB/788R) were designed using the most updated 611 Pseudomonas and 748 other bacterial gyrB genes for achieving high specificity. Their specificity showed 100% accuracy when tested with various strains including clinical isolates from cystic fibrosis patients. The assay was tested with P. aeruginosa-containing chlorinated water and aerosols to simulate the waterborne and airborne transmission routes (detection limit 3.3 × 102 CFU·PCR−1 − 2.3 × 103 CFU·PCR−1). No chlorine interference in real-time PCR was observed at drinking water level (~ 1 mg·L−1), but high level of chorine (12 mg·L−1) interfered the assay, thus neutralization was needed. P. aeruginosa in aerosol was successfully detected after capturing with gelatin filters with minimum 2 min of sampling time when the initial concentration of 104 CFU·mL−1 bacteria existed in the nebulizer. Conclusions A highly specific and rapid assay (2–3 hrs) was developed by targeting gyrB gene for the detection of P. aeruginosa in chlorinated water and aerosols, combined with optimized sample collection methods and sample processing, so the direct DNA extraction from either water or aerosol was possible while achieving the desired sensitivity of the method. Significance and Impact The new assay can provide timely and accurate risk assessment to prevent P. aeruginosa exposure from water and aerosol, resulting in reduced disease burden, especially among immune-compromised and susceptible individuals. This approach can be easily utilized as a platform technology for the detection of other types of microorganisms, especially for those that are transmitted via water and aerosol routes, such as Legionella pneumophila. PMID:21794031

  1. Methicillin-Resistant Staphylococcus aureus (MRSA) Detection: Comparison of Two Molecular Methods (IDI-MRSA PCR Assay and GenoType MRSA Direct PCR Assay) with Three Selective MRSA Agars (MRSA ID, MRSASelect, and CHROMagar MRSA) for Use with Infection-Control Swabs▿

    PubMed Central

    van Hal, S. J.; Stark, D.; Lockwood, B.; Marriott, D.; Harkness, J.

    2007-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an increasing problem. Rapid detection of MRSA-colonized patients has the potential to limit spread of the organism. We evaluated the sensitivities and specificities of MRSA detection by two molecular methods (IDI-MRSA PCR assay and GenoType MRSA Direct PCR assay) and three selective MRSA agars (MRSA ID, MRSASelect, and CHROMagar MRSA), using 205 (101 nasal, 52 groin, and 52 axillary samples) samples from consecutive known MRSA-infected and/or -colonized patients. All detection methods had higher MRSA detection rates for nasal swabs than for axillary and groin swabs. Detection of MRSA by IDI-MRSA was the most sensitive method, independent of the site (94% for nasal samples, 80% for nonnasal samples, and 90% overall). The sensitivities of the GenoType MRSA Direct assay and the MRSA ID, MRSASelect, and CHROMagar MRSA agars with nasal swabs were 70%, 72%, 68%, and 75%, respectively. All detection methods had high specificities (95 to 99%), independent of the swab site. Extended incubation for a further 24 h with selective MRSA agars increased the detection of MRSA, with a corresponding decline in specificity secondary to a significant increase in false-positive results. There was a noticeable difference in test performance of the GenoType MRSA Direct assay in detection of MRSA (28/38 samples [74%]) compared with detection of nonmultiresistant MRSA (17/31 samples [55%]) (susceptible to two or more non-β-lactam antibiotics). This was not observed with selective MRSA agar plates or IDI-MRSA. Although it is more expensive, in addition to rapid turnaround times of 2 to 4 h, IDI-MRSA offers greater detection of MRSA colonization, independent of the swab site, than do conventional selective agars and GenoType MRSA Direct. PMID:17537949

  2. Comparison of Phenotypic and Genotypic Methods for Detection of Diphtheria Toxin among Isolates of Pathogenic Corynebacteria

    PubMed Central

    Efstratiou, Androulla; Engler, Kathryn H.; Dawes, Charlotte S.; Sesardic, Dorothea

    1998-01-01

    We have compared molecular, immunochemical, and cytotoxic assays for the detection of diphtheria toxin from 55 isolates of Corynebacterium diphtheriae and Corynebacterium ulcerans originally isolated in five different countries. The suitabilities and accuracies of these assays for the laboratory diagnosis of diphtheria were compared and evaluated against the “gold standard” in vivo methods. The in vivo and Vero cell cytotoxicity assays were accurate in their abilities to detect diphtheria toxin but were time-consuming; however, the cytotoxicity assay is a suitable in vitro alternative to the in vivo virulence test. There was complete concordance between all the phenotypic methods. Genotypic tests based upon PCR were rapid; however, PCR must be used with caution because some isolates of C. diphtheriae possessed toxin genes but failed to express a biologically active toxin. Therefore, phenotypic confirmation of toxigenicity for the microbiological diagnosis of diphtheria is recommended. PMID:9774560

  3. Comparison of phenotypic and genotypic methods for detection of diphtheria toxin among isolates of pathogenic corynebacteria.

    PubMed

    Efstratiou, A; Engler, K H; Dawes, C S; Sesardic, D

    1998-11-01

    We have compared molecular, immunochemical, and cytotoxic assays for the detection of diphtheria toxin from 55 isolates of Corynebacterium diphtheriae and Corynebacterium ulcerans originally isolated in five different countries. The suitabilities and accuracies of these assays for the laboratory diagnosis of diphtheria were compared and evaluated against the "gold standard" in vivo methods. The in vivo and Vero cell cytotoxicity assays were accurate in their abilities to detect diphtheria toxin but were time-consuming; however, the cytotoxicity assay is a suitable in vitro alternative to the in vivo virulence test. There was complete concordance between all the phenotypic methods. Genotypic tests based upon PCR were rapid; however, PCR must be used with caution because some isolates of C. diphtheriae possessed toxin genes but failed to express a biologically active toxin. Therefore, phenotypic confirmation of toxigenicity for the microbiological diagnosis of diphtheria is recommended.

  4. Development and evaluation of an in-house single step loop-mediated isothermal amplification (SS-LAMP) assay for the detection of Mycobacterium tuberculosis complex in sputum samples from Moroccan patients.

    PubMed

    Bentaleb, El Mehdi; Abid, Mohammed; El Messaoudi, My Driss; Lakssir, Brahim; Ressami, El Mostafa; Amzazi, Saaïd; Sefrioui, Hassan; Ait Benhassou, Hassan

    2016-09-27

    Tuberculosis (TB) is a major global health problem and remains the leading cause of morbidity and mortality in developing countries. Routinely used TB diagnostic methods, in most endemic areas, are time-consuming, often less-sensitive, expensive and inaccessible to most patients. Therefore, there is an urgent need for the development of early, easy to use and effective diagnosis tools of TB, which can be effectively integrated into resource limited settings, to anticipate the early treatment and limit further spread of the disease. Over the last decade, Loop-mediated isothermal amplification (LAMP) assays have become a powerful tool for rapid diagnosis of infectious diseases because of the simplicity of device requirements. Indeed, LAMP is a simple, quick and cost effective Isothermal Nucleic Acid Amplification diagnostic test (INAAT) that has the potential to be used in TB endemic settings of resource-poor countries. In the present study, we have developed a simple and rapid TB molecular diagnostic test using a Single-Step Loop-mediated isothermal DNA amplification (SS-LAMP) method for the detection of Mycobacterium tuberculosis complex (MTBC) strains, with a simplified sample preparation procedure, eliminating DNA extraction prior to LAMP amplification, DNA initial denaturation and enzymatic inactivation steps during the amplification process. To perform our in-house SS-LAMP assay, a set of six specific primers was specifically designed to recognize eight distinct regions on the MTBC species-specific repetitive insertion sequence 6110 (IS6110). The amplification of the targeted DNA was carried out under isothermal conditions at 65 °C within 1 h. Our protocol was firstly optimized using 60 of confirmed MTBC isolates and a recombinant pGEMeasy-IS6110 vector for sensitivity testing. Thereafter, the assay was evaluated on liquefied sputum specimens collected from 157 Moroccan patients suspected of having TB. Our SS-LAMP developed assay was able to detect MTBC DNA directly from liquefied sputum samples without any prior DNA extraction, denaturation nor the final enzymatic inactivation step. When compared to routinely used Löwenstein Jensen (LJ) Culture method, our SS-LAMP assay is rapid and showed specificity and sensitivity of 99.14 % and 82.93 % respectively which are within the international standards. In addition, the limit of detection of our assay was found to be as little as 10 copies of bacterial DNA. To our knowledge, this is the first study using a single step LAMP (SS-LAMP) procedure as a rapid, easy to perform and cost effective testing for TB early detection. This innovative assay could be suitable for low-income countries with restricted health equipment facilities.

  5. Benefits and challenges of molecular diagnostics for childhood tuberculosis.

    PubMed

    Gutierrez, Cristina

    2016-12-01

    Expanding tuberculosis (TB)-diagnostic services, including access to rapid tests, is a World Health Organization (WHO) strategy to accelerate progress toward ending TB. Faster and more sensitive molecular tests capable of diagnosing TB and drug-resistant TB have the technical capacity to address limitations associated with smears and cultures by increasing accuracy and shortening turnaround times as compared with those of these conventional laboratory methods. Nucleic acid amplification assays used to detect and analyze Mycobacterium tuberculosis (MTB)-complex nucleic acids can be used directly on specimens from patients suspected of having TB. Recently, several commercial molecular tests were developed to detect MTB and determine the drug resistance (DR) based on detection of specific genetic mutations conferring resistance. The first to be endorsed by the WHO was molecular line-probe assay technology. This test uses polymerase chain reaction (PCR) and reverse-hybridization methods to rapidly identify MTB and DR-related mutations simultaneously. More recently, the WHO endorsed Xpert MTB/RIF, Cepheid Inc, CA, USA, a fully automated assay used for TB diagnosis that relies upon PCR techniques for detection of TB and rifampicin resistance-related mutations. Other promising molecular TB assays for simplifying PCR-based testing protocols and increasing their accuracy are under development and evaluation. Although we lack a practical gold standard for the diagnosis of childhood TB, its bacteriological confirmation is always recommended to be sought whenever possible prior to a diagnostic decision being made. Conventional diagnostic laboratory TB tests are less efficient for children as compared with adults, because sufficient sputum samples are more difficult to collect from infants and young children, and their disease is often paucibacillary, resulting in smear-negative disease. These inherent challenges associated with childhood TB are due to immunological- and pathophysiological-response differences relative to those observed in adults. Several recent meta-analyses showed low sensitivity estimates of PCR-based TB assays for paucibacillary forms of TB (extrapulmonary TB and smear-negative pulmonary disease), which represent the vast majority of childhood TB cases. Despite the lack of evidence regarding use of the rapid molecular assays to identify TB and detect DR in children, and due to the clinical nature of childhood TB, TB-expert groups recommend including rapid methods for TB identification and DR detection in diagnostic algorithms for children suspected of both smear-positive and -negative pulmonary or extrapulmonary TB, both with or without human immunodeficiency virus (HIV)-coinfection, when combined with standard methods (including clinical, microbiological, and radiological assessment) for diagnosing active TB and conventional DR. Since 2011, the WHO has specifically recommended use of the Xpert MTB/RIF test as an initial diagnostic tool for children with suspected HIV-associated TB or multidrug-resistant TB based on successful treatment data related to adults. Implementation of the rapid molecular assays for rapid detection of TB and DR should occur in laboratories with proven capability to run molecular tests and where quality control systems are implemented. Molecular approaches should be more largely tested in children, given their status as the group in whom the diagnostic dilemma is most pronounced. These tests should also be included in specific childhood TB diagnostic algorithms adapted to the local/national context in combination with other strategies for improving diagnostics, including more effective specimen collection. Copyright © 2016.

  6. Rapid PCR detection of group A Streptococcus from flocked throat swabs: a retrospective clinical study.

    PubMed

    Slinger, Robert; Goldfarb, David; Rajakumar, Derek; Moldovan, Ioana; Barrowman, Nicholas; Tam, Ronald; Chan, Francis

    2011-09-02

    Rapid diagnosis of GAS pharyngitis may improve patient care by ensuring that patients with GAS pharyngitis are treated quickly and also avoiding unnecessary use of antibiotics in those without GAS infection. Very few molecular methods for detection of GAS in clinical throat swab specimens have been described. We performed a study of a laboratory-developed internally-controlled rapid Group A streptococcus (GAS) PCR assay using flocked swab throat specimens. We compared the GAS PCR assay to GAS culture results using a collection of archived throat swab samples obtained during a study comparing the performance of conventional and flocked throat swabs. The sensitivity of the GAS PCR assay as compared to the reference standard was 96.0% (95% CI 90.1% to 98.4%), specificity 98.6% (95% CI 95.8% to 99.5%), positive predictive value (PPV) 96.9% (95% CI 91.4% to 99.0%) and negative predictive value (NPV) of 98.1% (95% CI 95.2% to 99.2%). For conventional swab cultures, sensitivity was 96.0% (95% CI 90.1% to 98.4%), specificity 100% (95% CI 98.2% to 100%), PPV 100%, (95% CI 96.1% to 100%) and NPV 98.1% (95% CI 95.2% to 99.3%) In this retrospective study, the GAS PCR assay appeared to perform as well as conventional throat swab culture, the current standard of practice. Since the GAS PCR assay, including DNA extraction, can be performed in approximately 1 hour, prospective studies of this assay are warranted to evaluate the clinical impact of the assay on management of patients with pharyngitis.

  7. Mini-column assay for rapid detection of malachite green in fish.

    PubMed

    Shalaby, Ali R; Emam, Wafaa H; Anwar, Mervat M

    2017-07-01

    A simple, rapid and economical mini-column method for detecting malachite green (MG) residue in fish was developed. The method used a column with 2mm ID that was tightly packed with silica gel followed by alumina. Detection of MG was performed by viewing the developed mini-column at visible light by naked eye; where MG was seen as compact green band at the confluence of the silica gel layer with alumina layer. The limit of detection of the assay was 2ng which conform the minimum required performance limit (MRPL). Evaluation utility of the method indicated that all blank and spiked samples at levels below MRPL were assessed as accepted. The intensity of the green band increased whenever MG level in the extract increased; indicated that suggested mini-column technique could be used for semi-quantitative determination of MG in fish samples. The method can be used to select the questionable samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Validation Study of Rapid Assays of Bioburden, Endotoxins and Other Contamination.

    PubMed

    Shintani, Hideharu

    2016-01-01

    Microbial testing performed in support of pharmaceutical and biopharmaceutical production falls into three main categories: detection (qualitative), enumeration (quantitative), and characterization/identification. Traditional microbiological methods are listed in the compendia and discussed by using the conventional growth-based techniques, which are labor intensive and time consuming. In general, such tests require several days of incubation for microbial contamination (bioburden) to be detected, and therefore management seldom is able to take proactive corrective measures. In addition, microbial growth is limited by the growth medium used and incubation conditions, thus impacting testing sensitivity, accuracy, and reproducibility.  For more than 20 years various technology platforms for rapid microbiological methods (RMM) have been developed, and many have been readily adopted by the food industry and clinical microbiology laboratories. Their use would certainly offer drug companies faster test turnaround times to accommodate the aggressive deadlines for manufacturing processes and product release. Some rapid methods also offer the possibility for real-time microbial analyses, enabling management to respond to microbial contamination events in a more timely fashion, and can provide cost savings and higher efficiencies in quality control testing laboratories. Despite the many proven business and quality benefits and the fact that the FDA's initiative to promote the use of process analytical technology (PAT) includes rapid microbial methods, pharmaceutical and biopharmaceutical industries have been somewhat slow to embrace alternative microbial methodologies for several reasons. The major reason is that the bioburden counts detected by the incubation method and rapid assay are greatly divergent.  The use of rapid methods is a dynamic field in applied microbiology and one that has gained increased attention nationally and internationally over time. This topic has been extensively addressed at conferences and in published documents around the world. More recently, the use of alternative methods for control of the microbiological quality of pharmaceutical products and materials used in pharmaceutical production has been addressed by the compendia in an attempt to facilitate implementation of these technologies by pharmaceutical companies. The author presents some of the rapid method technologies under evaluation or in use by pharmaceutical microbiologists and the current status of the implementation of alternative microbial methods.

  9. Rapid and accurate identification by real-time PCR of biotoxin-producing dinoflagellates from the family gymnodiniaceae.

    PubMed

    Smith, Kirsty F; de Salas, Miguel; Adamson, Janet; Rhodes, Lesley L

    2014-03-07

    The identification of toxin-producing dinoflagellates for monitoring programmes and bio-compound discovery requires considerable taxonomic expertise. It can also be difficult to morphologically differentiate toxic and non-toxic species or strains. Various molecular methods have been used for dinoflagellate identification and detection, and this study describes the development of eight real-time polymerase chain reaction (PCR) assays targeting the large subunit ribosomal RNA (LSU rRNA) gene of species from the genera Gymnodinium, Karenia, Karlodinium, and Takayama. Assays proved to be highly specific and sensitive, and the assay for G. catenatum was further developed for quantification in response to a bloom in Manukau Harbour, New Zealand. The assay estimated cell densities from environmental samples as low as 0.07 cells per PCR reaction, which equated to three cells per litre. This assay not only enabled conclusive species identification but also detected the presence of cells below the limit of detection for light microscopy. This study demonstrates the usefulness of real-time PCR as a sensitive and rapid molecular technique for the detection and quantification of micro-algae from environmental samples.

  10. Biompha-LAMP: A New Rapid Loop-Mediated Isothermal Amplification Assay for Detecting Schistosoma mansoni in Biomphalaria glabrata Snail Host.

    PubMed

    Gandasegui, Javier; Fernández-Soto, Pedro; Hernández-Goenaga, Juan; López-Abán, Julio; Vicente, Belén; Muro, Antonio

    2016-12-01

    Schistosomiasis remains one of the most common endemic parasitic diseases affecting over 230 million people worlwide. Schistosoma mansoni is the main species causing intestinal and hepatic schistosomiasis and the fresh water pulmonate snails of the genus Biomphalaria are best known for their role as intermediate hosts of the parasite. The development of new molecular monitoring assays for large-scale screening of snails from transmission sites to detect the presence of schistosomes is an important point to consider for snail control interventions related to schistosomiasis elimination. Our work was focussed on developing and evaluating a new LAMP assay combined with a simple DNA extraction method to detect S. mansoni in experimentally infected snails as a diagnostic tool for field conditions. A LAMP assay using a set of six primers targeting a sequence of S. mansoni ribosomal intergenic spacer 28S-18S rRNA was designed. The detection limit of the LAMP assay was 0.1 fg of S. mansoni DNA at 63°C for 50 minutes. LAMP was evaluated by examining S. mansoni DNA in B. glabrata snails experimentally exposed to miracidia at different times post-exposure: early prepatent period (before cercarial shedding), light infections (snails exposed to a low number of miracidia) and detection of infected snails in pooled samples (within a group of uninfected snails). DNA for LAMP assays was obtained by using a commercial DNA extraction kit or a simple heat NaOH extraction method. We detected S. mansoni DNA in all groups of snails by using no complicated requirement procedure for DNA obtaining. Our LAMP assay, named Biompha-LAMP, is specific, sensitive, rapid and potentially adaptable as a cost-effective method for screening of intermediate hosts infected with S. mansoni in both individual snails and pooled samples. The assay could be suitable for large-scale field surveys for schistosomes control campaigns in endemic areas.

  11. Biompha-LAMP: A New Rapid Loop-Mediated Isothermal Amplification Assay for Detecting Schistosoma mansoni in Biomphalaria glabrata Snail Host

    PubMed Central

    Hernández-Goenaga, Juan; López-Abán, Julio; Vicente, Belén; Muro, Antonio

    2016-01-01

    Background Schistosomiasis remains one of the most common endemic parasitic diseases affecting over 230 million people worlwide. Schistosoma mansoni is the main species causing intestinal and hepatic schistosomiasis and the fresh water pulmonate snails of the genus Biomphalaria are best known for their role as intermediate hosts of the parasite. The development of new molecular monitoring assays for large-scale screening of snails from transmission sites to detect the presence of schistosomes is an important point to consider for snail control interventions related to schistosomiasis elimination. Our work was focussed on developing and evaluating a new LAMP assay combined with a simple DNA extraction method to detect S. mansoni in experimentally infected snails as a diagnostic tool for field conditions. Methodology/Principal findings A LAMP assay using a set of six primers targeting a sequence of S. mansoni ribosomal intergenic spacer 28S-18S rRNA was designed. The detection limit of the LAMP assay was 0.1 fg of S. mansoni DNA at 63°C for 50 minutes. LAMP was evaluated by examining S. mansoni DNA in B. glabrata snails experimentally exposed to miracidia at different times post-exposure: early prepatent period (before cercarial shedding), light infections (snails exposed to a low number of miracidia) and detection of infected snails in pooled samples (within a group of uninfected snails). DNA for LAMP assays was obtained by using a commercial DNA extraction kit or a simple heat NaOH extraction method. We detected S. mansoni DNA in all groups of snails by using no complicated requirement procedure for DNA obtaining. Conclusions/Significance Our LAMP assay, named Biompha-LAMP, is specific, sensitive, rapid and potentially adaptable as a cost-effective method for screening of intermediate hosts infected with S. mansoni in both individual snails and pooled samples. The assay could be suitable for large-scale field surveys for schistosomes control campaigns in endemic areas. PMID:27941967

  12. Development of a rapid assay to detect the jellyfish Cyanea nozakii using a loop-mediated isothermal amplification method.

    PubMed

    Liu, Zhongyuan; Dong, Zhijun; Liu, Dongyan

    2016-07-01

    Blooms of the harmful jellyfish Cyanea nozakii, which are a severe nuisance to fisheries and tourisms, frequently occur in the northern East China Sea, Yellow Sea, and Bohai Sea. To provide early warning of this species, a simple and effective molecular method for identifying C. nozakii was developed using the loop-mediated isothermal amplification method (LAMP). The LAMP assay is highly specific and uses a set of four primers that target six different regions on the mitochondrial cytochrome c oxidase subunit I (COI) gene of C. nozakii. The amplification conditions, including the dNTP and betaine concentrations, the inner primer to outer primer concentration ratio, reaction time and temperature, were optimized. The LAMP assay amplified DNA extracted from tissue samples of C. nozakii but did not amplify DNA from other common scyphozoans and hydrozoans collected in the same region. In addition, the LAMP assay was more sensitive than conventional PCR. Therefore, the established LAMP assay is a sensitive, specific, fast, and easily performed method for detection of C. nozakii at different stages in their life cycle.

  13. Expanding the Use of a Fluorogenic Method to Determine Activity and Mode of Action of Bacillus thuringiensis Bacteriocins Against Gram-Positive and Gram-Negative Bacteria

    PubMed Central

    de la Fuente-Salcido, Norma M.; Barboza-Corona, J. Eleazar; Espino Monzón, A. N.; Pacheco Cano, R. D.; Balagurusamy, N.; Bideshi, Dennis K.; Salcedo-Hernández, Rubén

    2012-01-01

    Previously we described a rapid fluorogenic method to measure the activity of five bacteriocins produced by Mexican strains of Bacillus thuringiensis against B. cereus 183. Here we standardize this method to efficiently determine the activity of bacteriocins against both Gram-positive and Gram-negative bacteria. It was determined that the crucial parameter required to obtain reproducible results was the number of cells used in the assay, that is, ~4 × 108 cell/mL and ~7 × 108 cell/mL, respectively, for target Gram-positive and Gram-negative bacteria. Comparative analyses of the fluorogenic and traditional well-diffusion assays showed correlation coefficients of 0.88 to 0.99 and 0.83 to 0.99, respectively, for Gram-positive and Gram-negative bacteria. The fluorogenic method demonstrated that the five bacteriocins of B. thuringiensis have bacteriolytic and bacteriostatic activities against all microorganisms tested, including clinically significant bacteria such as Listeria monocytogenes, Proteus vulgaris, and Shigella flexneri reported previously to be resistant to the antimicrobials as determined using the well-diffusion protocol. These results demonstrate that the fluorogenic assay is a more sensitive, reliable, and rapid method when compared with the well-diffusion method and can easily be adapted in screening protocols for bacteriocin production by other microorganisms. PMID:22919330

  14. Validation of paper-based assay for rapid blood typing.

    PubMed

    Al-Tamimi, Mohammad; Shen, Wei; Zeineddine, Rania; Tran, Huy; Garnier, Gil

    2012-02-07

    We developed and validated a new paper-based assay for the detection of human blood type. Our method involves spotting a 3 μL blood sample on a paper surface where grouping antibodies have already been introduced. A thin film chromatograph tank was used to chromatographically elute the blood spot with 0.9% NaCl buffer for 10 min by capillary absorption. Agglutinated red blood cells (RBCs) were fixed on the paper substrate, resulting in a high optical density of the spot, with no visual trace in the buffer wicking path. Conversely, nonagglutinated RBCs could easily be eluted by the buffer and had low optical density of the spot and clearly visible trace of RBCs in the buffer wicking path. Different paper substrates had comparable ability to fix agglutinated blood, while a more porous substrate like Kleenex paper had enhanced ability to elute nonagglutinated blood. Using optimized conditions, a rapid assay for detection of blood groups was developed by spotting blood to antibodies absorbed to paper and eluted with 200 μL of 0.9% NaCl buffer directly by pipetting. RBCs fixation on paper accurately detected blood groups (ABO and RhD) using ascending buffer for 10 min or using a rapid elution step in 100/100 blood samples including 4 weak AB and 4 weak RhD samples. The assay has excellent reproducibility where the same blood group was obtained in 26 samples assessed in 2 different days. Agglutinated blood fixation on porous paper substrate provides a new, simple, and sensitive assay for rapid detection of blood group for point-of-care applications. © 2011 American Chemical Society

  15. Rapid detection of the Klebsiella pneumoniae carbapenemase (KPC) gene by loop-mediated isothermal amplification (LAMP).

    PubMed

    Nakano, Ryuichi; Nakano, Akiyo; Ishii, Yoshikazu; Ubagai, Tsuneyuki; Kikuchi-Ueda, Takane; Kikuchi, Hirotoshi; Tansho-Nagakawa, Shigeru; Kamoshida, Go; Mu, Xiaoqin; Ono, Yasuo

    2015-03-01

    Klebsiella pneumoniae carbapenemases (KPC), which are associated with resistance to carbapenem, have recently spread worldwide and have become a global concern. It is necessary to detect KPC-producing organisms in clinical settings to be able to control the spread of this resistance. We have developed a loop-mediated isothermal amplification (LAMP) method for rapid detection of KPC producers. LAMP primer sets were designed to recognize the homologous regions of blaKPC-2 to blaKPC-17 and could amplify blaKPC rapidly. The specificity and sensitivity of the primers in the LAMP reactions for blaKPC detection were determined. This LAMP assay was able to specifically detect KPC producers at 68 °C, and no cross-reactivity was observed for other types of β-lactamase (class A, B, C, or D) producers. The detection limit for this assay was found to be 10(0) CFU per tube, in 25 min, which was 10-fold more sensitive than a PCR assay for blaKPC detection. Then, the sensitivity of the LAMP reactions for blaKPC detection in human specimens (sputum samples, urine samples, fecal samples and blood samples) was analyzed; it was observed that the LAMP assay had almost the same sensitivity in these samples as when using purified DNA. The LAMP assay is easy to perform and rapid. It may therefore be routinely applied for detection of KPC producers in the clinical laboratory. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  16. Two novel assays for the detection of haemin-binding properties of antimalarials evaluated with compounds isolated from medicinal plants.

    PubMed

    Steele, J C P; Phelps, R J; Simmonds, M S J; Warhurst, D C; Meyer, D J

    2002-07-01

    Forty-two compounds isolated from nine plants used within South America for the treatment of malaria were tested for haemin binding using two novel, rapid screening methods. The data obtained were analysed with respect to IC(50) values for in vitro toxicity to Plasmodium falciparum trophozoites. One method, a multiwell assay based on the inhibition of the interaction of haemin with glutathione (GSH), is sensitive in the 10 microM range, takes c. 1 h and is suitable for either a high throughput screen or rapid assay during natural product isolation. Of 19 compounds showing antiplasmodial activity (IC(50) < 40 microM), 16 (84%) showed >40% inhibition of GSH-haemin reaction. The sensitivity and specificity of the assay were 0.85 and 0.82, respectively. The positive predictive value was 0.81 and the negative predictive value 0.86. A more sensitive assay (0.1 microM range) is based on the reversal by haemin-binding compounds of the haemin inhibition of the L-dopachrome-methyl ester tautomerase activity of human macrophage migration inhibitory factor. This assay gives a better idea of the affinity of interaction and uses very small amounts of test compound. The log[RI(50)] of eight of the compounds that tested positive in the above assays together with those of quinine and chloroquine showed a positive correlation with log[antiplasmodial IC(50)] for strain T9-96 (r = 0.824) and strain K1 (r = 0.904). Several of the antimalarial compounds that bind haemin are isoquinolines, a class not shown previously to interact with haemin.

  17. Development and validation of a real-time PCR assay for the detection of Toxoplasma gondii DNA in animal and meat samples.

    PubMed

    Marino, Anna Maria Fausta; Percipalle, Maurizio; Giunta, Renato Paolo; Salvaggio, Antonio; Caracappa, Giulia; Alfonzetti, Tiziana; Aparo, Alessandra; Reale, Stefano

    2017-03-01

    We report a rapid and reliable method for the detection of Toxoplasma gondii in meat and animal tissues based on real-time polymerase chain reaction (PCR). Samples were collected from cattle, small ruminants, horses, and pigs raised or imported into Sicily, Italy. All DNA preparations were assayed by real-time PCR tests targeted to a 98-bp long fragment in the AF 529-bp repeat element and to the B1 gene using specific primers. Diagnostic sensitivity (100%), diagnostic specificity (100%), limit of detection (0.01 pg), efficiency (92-109%), and precision (mean coefficient of variation = 0.60%), repeatability (100%), reproducibility (100%), and robustness were evaluated using 240 DNA extracted samples (120 positives and 120 negative as per the OIE nested PCR method) from different matrices. Positive results were confirmed by the repetition of both real-time and nested PCR assays. Our study demonstrates the viability of a reliable, rapid, and specific real-time PCR on a large scale to monitor contamination with Toxoplasma cysts in meat and animal specimens. This validated method can be used for postmortem detection in domestic and wild animals and for food safety purposes.

  18. Rapid and high resolution genotyping of all Escherichia coli serotypes using 10 genomic repeat-containing loci.

    PubMed

    Løbersli, Inger; Haugum, Kjersti; Lindstedt, Bjørn-Arne

    2012-01-01

    Our laboratory has previously published two multiple-locus variable-number tandem-repeats analysis (MLVA) methods for rapid genotyping of Escherichia coli (E. coli), which are now in routine use for surveillance and outbreak detection. The first assay developed was specific for E. coli O157:H7; however this assay was not suitable for genotyping other E. coli serotypes. A new generic MLVA-assay was then developed with the capability of genotyping all E. coli serotypes. This generic E. coli MLVA (GECM7) was based on polymorphism in seven variable number of tandem repeats (VNTR) loci. GECM7 worked well with the majority of E. coli serotypes; however we wanted to increase the resolution for this method based in part of comparison with PFGE typing of E. coli O26:H11, where PFGE appeared to display higher resolution. The GECM7 method was improved by adding three new repeat-loci to a total of ten (GECM10), and a considerable increase in resolution was observed (from 296 to 507 genotypes on the same set of strains). Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Development of a real-time PCR assay for rapid detection and quantification of Photobacterium damselae subsp. piscicida in fish tissues.

    PubMed

    Carraro, R; Dalla Rovere, G; Ferraresso, S; Carraro, L; Franch, R; Toffan, A; Pascoli, F; Patarnello, T; Bargelloni, L

    2018-02-01

    The availability of a rapid and accurate method for the diagnosis of Photobacterium damselae subsp. piscicida (Phdp), able to discriminate its strictly correlated subsp. damselae (Phdd), formally known as Vibrio damsela, is essential for managing fish pasteurellosis outbreaks in farmed fish. A single-step, high-sensitivity real-time PCR assay for simultaneous detection and quantification of P. damselae was designed targeting partial of the sequence of the bamB gene and tested for specificity and sensitivity on laboratory-generated samples as well as on experimentally infected seabream tissue samples. With a limit of detection (LOD) of one copy in pure bacterial DNA, the sensitivity was higher than all methods previously reported. Validation in target and non-target bacterial species proved the assay was able to discriminate Phdd-Phdp subspecies from diverse hosts/geographical origins and between non-target species. In addition, two SNPs in the target amplicon region determine two distinctive qPCR dissociation curves distinguishing between Phdp-Phdd. This is the first time that a molecular method for P. damselae diagnosis combines detection, quantification and subspecies identification in one step. The assay holds the potential to improve the knowledge of infection dynamics and the development of better strategies to control an important fish disease. © 2017 John Wiley & Sons Ltd.

  20. A simple and rapid method for optical visualization and quantification of bacteria on textiles

    PubMed Central

    Stiefel, Philipp; Schneider, Jana; Amberg, Caroline; Maniura-Weber, Katharina; Ren, Qun

    2016-01-01

    To prevent bacterial contamination on textiles and the associated undesired effects different biocidal coatings have been investigated and applied. However, due to health and environmental concerns anti-adhesive coatings preventing the binding of bacteria would be favored. To develop such anti-adhesive coatings simple assays for reliable and fast screening are beneficial. Here an easy-to-handle, robust and rapid assay to assess bacteria on textiles utilizing a tetrazolium salt was reported. The assay allowed direct eye visualization of the color change of the textiles containing bacteria, facilitating fast screening. Quantification of the adhered bacteria could be done by generating standard curves which correlate the staining intensity to cell numbers. An additional advantage of the described assay is that with the same detection method anti-adhesive and biocidal effects can be investigated. The method was applied to different coatings, using Pseudomonas aeruginosa and Staphylococcus aureus as model organisms. The detection limit was found to be between 2.5 * 106 and 9.4 * 108 for P. aeruginosa and between 1 * 106 and 3.3 * 108 for S. aureus. The anti-adhesive coating PLUMA was demonstrated to reduce bacterial adhesion without killing them, whereas the biocidal coating TH22-27 caused a clear reduction in the number of viable cells. PMID:28004762

  1. A Four-Hour Yeast Bioassay for the Direct Measure of Estrogenic Activity in Wastewater without Sample Extraction, Concentration, or Sterilization

    PubMed Central

    Balsiger, Heather A.; de la Torre, Roberto; Lee, Wen-Yee; Cox, Marc B.

    2010-01-01

    The assay described here represents an improved yeast bioassay that provides a rapid yet sensitive screening method for EDCs with very little hands-on time and without the need for sample preparation. Traditional receptor-mediated reporter assays in yeast were performed twelve to twenty four hours after ligand addition, used colorimetric substrates, and, in many cases, required high, non-physiological concentrations of ligand. With the advent of new chemiluminescent substrates a ligand-induced signal can be detected within thirty minutes using high picomolar to low nanomolar concentrations of estrogen. As a result of the sensitivity (EC50 for estradiol is ~ 0.7 nM) and the very short assay time (2-4 hours) environmental water samples can typically be assayed directly without sterilization, extraction, and concentration. Thus, these assays represent rapid and sensitive approaches for determining the presence of contaminants in environmental samples. As proof of principle, we directly assayed wastewater influent and effluent taken from a wastewater treatment plant in the El Paso, TX area for the presence of estrogenic activity. The data obtained in the four-hour yeast bioassay directly correlated with GC-mass spectrometry analysis of these same water samples. PMID:20074779

  2. A microplate assay for measuring cell death in C2C12 cells.

    PubMed

    Lima, Tanes; Silveira, Leonardo

    2018-03-22

    The main goal of this study was to develop a straightforward and rapid microplate assay for measuring propidium iodide (PI) in C2C12 cells. The PI method proves to be an efficient quantitative assay for analyzing cell viability through PI fluorescence analysis. Importantly, the protocol takes less than 30 minutes, and the results are reproducible. C2C12 cells were exposed to an increasing concentration of palmitate for a period of 24 hours to induce cell death, and the PI fluorescence increased in a concentration-dependent manner. Evaluation of mitochondrial function and reactive oxygen species production validated the deleterious effects of palmitate treatment. Also, the microplate PI assay demonstrated high sensitivity as indicated by the detection of modest fluctuations in cell viability in response to catalase overexpression in palmitate-treated cells. The microplate PI assay, therefore, offers an accurate method to be used for in vitro studies.

  3. Analytical performances of the Diazyme ADA assay on the Cobas® 6000 system.

    PubMed

    Delacour, Hervé; Sauvanet, Christophe; Ceppa, Franck; Burnat, Pascal

    2010-12-01

    To evaluate the analytical performance of the Diazyme ADA assay on the Cobas® 6000 system for pleural fluid samples analysis. Imprecision, linearity, calibration curve stability, interference, and correlation studies were completed. The Diazyme ADA assay demonstrated excellent precision (CV<4%) over the analytical measurement range (0.5-117 U/L). Bilirubin above 50 μmol/L and haemoglobin above 177 μmol/L interfered with the test, inducing a negative and a positive interference respectively. The Diazyme ADA assay correlated well with the Giusti method (r(2)=0.93) but exhibited a negative bias (~ -30%). The Diazyme ADA assay on the Cobas® 6000 system represents a rapid, accurate, precise and reliable method for determination of ADA activity in pleural fluid samples. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of efficiency of nested multiplex allele-specific PCR assay for detection of multidrug resistant tuberculosis directly from sputum samples.

    PubMed

    Mistri, S K; Sultana, M; Kamal, S M M; Alam, M M; Irin, F; Nessa, J; Ahsan, C R; Yasmin, M

    2016-05-01

    For an effective control of tuberculosis, rapid detection of multidrug resistant tuberculosis (MDR-TB) is necessary. Therefore, we developed a modified nested multiplex allele-specific polymerase chain reaction (MAS-PCR) method that enables rapid MDR-TB detection directly from sputum samples. The efficacy of this method was evaluated using 79 sputum samples collected from suspected tuberculosis patients. The performance of nested MAS-PCR method was compared with other MDR-TB detection methods like drug susceptibility testing (DST) and DNA sequencing. As rifampicin (RIF) resistance conforms to MDR-TB in greater than 90% cases, only the presence of RIF-associated mutations in rpoB gene was determined by DNA sequencing and nested MAS-PCR to detect MDR-TB. The concordance between nested MAS-PCR and DNA sequencing results was found to be 96·3%. When compared with DST, the sensitivity and specificity of nested MAS-PCR for RIF-resistance detection were determined to be 92·9 and 100% respectively. For developing- and high-TB burden countries, molecular-based tests have been recommended by the World Health Organization for rapid detection of MDR-TB. The results of this study indicate that, nested MAS-PCR assay might be a practical and relatively cost effective molecular method for rapid detection of MDR-TB from suspected sputum samples in developing countries with resource poor settings. © 2016 The Society for Applied Microbiology.

  5. The narrow therapeutic window of glycated hemoglobin and assay variability.

    PubMed

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  6. Assays for Determination of Protein Concentration.

    PubMed

    Olson, Bradley J S C

    2016-06-01

    Biochemical analysis of proteins relies on accurate quantification of protein concentration. Detailed in this appendix are some commonly used methods for protein analysis, e.g., Lowry, Bradford, bicinchoninic acid (BCA), UV spectroscopic, and 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde (CBQCA) assays. The primary focus of this report is assay selection, emphasizing sample and buffer compatibility. The fundamentals of generating protein assay standard curves and of data processing are considered, as are high-throughput adaptations of the more commonly used protein assays. Also included is a rapid, inexpensive, and reliable BCA assay of total protein in SDS-PAGE sample buffer that is used for equal loading of SDS-PAGE gels. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  7. Development, standardization and validation of molecular techniques for malaria vector species identification, trophic preferences, and detection of Plasmodium falciparum.

    PubMed

    Rath, Animesha; Prusty, Manas R; Barik, Sushanta K; Das, Mumani; Tripathy, Hare K; Mahapatra, Namita; Hazra, Rupenangshu K

    2017-01-01

    Knowledge on prevalence of malaria vector species of a certain area provides important information for implementation of appropriate control strategies. The present study describes a rapid method for screening of major Anopheline vector species and at the same time detection of Plasmodium falciparum sporozoite infection and blood meal preferences/trophic preferences. The study was carried from February 2012 to March 2013 in three seasons, i.e. rainy, winter and summer in Jhumpura PHC of Keonjhar district, Odisha, India. Processing of mosquitoes was carried out in two different methods, viz. mosquito pool (P1) and mosquito DNA pool (P2). Pool size for both the methods was standardized for DNA isolation and multiplex PCR assay. This PCR based assay was employed to screen the major vector com- position in three different seasons of four different ecotypes of Keonjhar district. Pearson's correlation coefficient was determined for a comparative analysis of the morphological identification with the pool prevalence assay for each ecotype. A pool size of 10 was standardized for DNA isolation as well as PCR. PCR assay revealed that the average pool prevalence for all ecotypes was highest for An. annularis in winter and summer whereas for An. culicifacies it was rainy season. Foothill and plain ecotypes contributed to highest and lowest vectorial abundance respectively. The results of the prevalence of vector species in pool from PCR based assay were found to be highly correlated with that of the results of morphological identification. Screening by pool based PCR assay is relatively rapid as compared to conventional identification and can be employed as an important tool in malaria control programmes.

  8. The development of a loop-mediated isothermal amplification assay for rapid and sensitive detection of abalone herpesvirus DNA.

    PubMed

    Chen, M H; Kuo, S T; Renault, T; Chang, P H

    2014-02-01

    A loop-mediated isothermal amplification (LAMP) assay was developed for the detection of abalone herpesvirus DNA. Two pairs of primers were designed, based on the sequence of the DNA polymerase gene of abalone herpesvirus. The reaction temperature and time were optimized to 63°C and 60min, respectively. LAMP amplicons were analyzed by 2% agarose gel electrophoresis or by visual inspection of a colour change emitted by fluorescent dye. The method developed was specific for the detection of abalone herpesvirus, without cross-reactions with other tested herpesviruses including ostreid herpesvirus 1 (OsHV-1), European eel herpesvirus, koi herpesvirus (KHV) and an avian herpesvirus. The LAMP assay was 100 folds more sensitive than a conventional PCR and 10 folds less sensitive than a SYBR Green PCR. These results indicate that the developed LAMP assay is a simple, rapid, sensitive, specific and reliable technique for the detection of abalone herpesvirus. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Multi-Dimensional Measurement of Antibody-Mediated Heterosubtypic Immunity to Influenza.

    PubMed

    Wang, Jiong; Hilchey, Shannon P; Hyrien, Ollivier; Huertas, Nelson; Perry, Sheldon; Ramanunninair, Manojkumar; Bucher, Doris; Zand, Martin S

    2015-01-01

    The human immune response to influenza vaccination depends in part on preexisting cross-reactive (heterosubtypic) immunity from previous infection by, and/or vaccination with, influenza strains that share antigenic determinants with the vaccine strains. However, current methods for assessing heterosubtypic antibody responses against influenza, including the hemagglutination-inhibition (HAI) assay and ELISA, are time and labor intensive, and require moderate amounts of serum and reagents. To address these issues we have developed a fluorescent multiplex assay, mPlex-Flu, that rapidly and simultaneously measures strain specific IgG, IgA, and IgM antibodies against influenza hemagglutinin (HA) from multiple viral strains. We cloned, expressed and purified HA proteins from 12 influenza strains, and coupled them to multiplex beads. Assay validation showed that minimal sample volumes (<5 μl of serum) were needed, and the assay had a linear response over a four Log10 range. The assay detected nanogram levels of anti-influenza specific antibodies, had high accuracy and reproducibility, with an average percentage coefficient of variation (%CV) of 9.06 for intra-assay and 12.94 for inter-assay variability. Pre- and post-intramuscular trivalent influenza vaccination levels of virus specific Ig were consistent with HAI titer and ELISA measurements. A significant advantage of the mPLEX-Flu assay over the HAI assay is the ability to perform antigenic cartography, determining the antigenic distances between influenza HA's, without mathematical correction for HAI data issues. For validation we performed antigenic cartography on 14 different post-influenza infection ferret sera assayed against 12 different influenza HA's. Results were in good agreement with a phylogenetic tree generated from hierarchical clustering of the genomic HA sequences. This is the first report of the use of a multiplex method for antigenic cartography using ferret sera. Overall, the mPlex-Flu assay provides a powerful tool to rapidly assess the influenza antibody repertoire in large populations and to study heterosubtypic immunity induced by influenza vaccination.

  10. Multi-Dimensional Measurement of Antibody-Mediated Heterosubtypic Immunity to Influenza

    PubMed Central

    Wang, Jiong; Hilchey, Shannon P.; Hyrien, Ollivier; Huertas, Nelson; Perry, Sheldon; Ramanunninair, Manojkumar; Bucher, Doris; Zand, Martin S.

    2015-01-01

    The human immune response to influenza vaccination depends in part on preexisting cross-reactive (heterosubtypic) immunity from previous infection by, and/or vaccination with, influenza strains that share antigenic determinants with the vaccine strains. However, current methods for assessing heterosubtypic antibody responses against influenza, including the hemagglutination-inhibition (HAI) assay and ELISA, are time and labor intensive, and require moderate amounts of serum and reagents. To address these issues we have developed a fluorescent multiplex assay, mPlex-Flu, that rapidly and simultaneously measures strain specific IgG, IgA, and IgM antibodies against influenza hemagglutinin (HA) from multiple viral strains. We cloned, expressed and purified HA proteins from 12 influenza strains, and coupled them to multiplex beads. Assay validation showed that minimal sample volumes (<5 μl of serum) were needed, and the assay had a linear response over a four Log10 range. The assay detected nanogram levels of anti-influenza specific antibodies, had high accuracy and reproducibility, with an average percentage coefficient of variation (%CV) of 9.06 for intra-assay and 12.94 for inter-assay variability. Pre- and post-intramuscular trivalent influenza vaccination levels of virus specific Ig were consistent with HAI titer and ELISA measurements. A significant advantage of the mPLEX-Flu assay over the HAI assay is the ability to perform antigenic cartography, determining the antigenic distances between influenza HA’s, without mathematical correction for HAI data issues. For validation we performed antigenic cartography on 14 different post-influenza infection ferret sera assayed against 12 different influenza HA’s. Results were in good agreement with a phylogenetic tree generated from hierarchical clustering of the genomic HA sequences. This is the first report of the use of a multiplex method for antigenic cartography using ferret sera. Overall, the mPlex-Flu assay provides a powerful tool to rapidly assess the influenza antibody repertoire in large populations and to study heterosubtypic immunity induced by influenza vaccination. PMID:26103163

  11. A rapid inoculation technique for assessing pathogenicity of Fusarium oxysporum f. sp. niveum and F. o. melonis on Cucurbits

    USGS Publications Warehouse

    Freeman, S.; Rodriguez, R.J.

    1993-01-01

    A continuous-dip inoculation technique for rapid assessment of pathogenicity of Fusarium oxysporum f. sp. niveum and F. o. melonis was developed. The method, adapted from a similar procedure for determining pathogenicity of Colletotrichum magna (causal agent of anthracnose of cucurbits), involves constant exposure of seedlings and cuttings (seedlings with root systems excised) of watermelon and muskmelon to conidial suspensions contained in small scintillation vials. Disease development in intact seedlings corresponded well to disease responses observed with the standard root-dip inoculation/pot assay. The continuous-dip inoculation technique resulted in rapid disease development, with 50% of watermelon cuttings dying after 4–6 days of exposure to F. o. niveum. A mortality of 30% also was observed in watermelon cuttings exposed to conidia of F. o. melonis, as opposed to only a 0–2.5% mortality in seedlings with intact roots. Disease response was similar with muskmelon seedlings and cuttings continuously dip-inoculated with F. o. melonis isolates. However, no disease symptoms were observed in muskmelon seedlings or cuttings inoculated with F. o. niveum. Four nonpathogenic isolates of F. oxysporum did not cause disease symptoms in either watermelon or muskmelon cuttings and seedlings when assayed by this technique. The proposed method enables a rapid screening of pathogenicity and requires less time, labor, and greenhouse space than the standard root-dip inoculation/pot assay. The reliability of the continuous-dip inoculation technique is limited, however, to exposure of intact seedlings at a concentration of 1 × 106conidia per milliliter; the method is not accurate at this range for excised seedlings.

  12. High-resolution melting (HRM) assay for the detection of recurrent BRCA1/BRCA2 germline mutations in Tunisian breast/ovarian cancer families.

    PubMed

    Riahi, Aouatef; Kharrat, Maher; Lariani, Imen; Chaabouni-Bouhamed, Habiba

    2014-12-01

    Germline deleterious mutations in the BRCA1/BRCA2 genes are associated with an increased risk for the development of breast and ovarian cancer. Given the large size of these genes the detection of such mutations represents a considerable technical challenge. Therefore, the development of cost-effective and rapid methods to identify these mutations became a necessity. High resolution melting analysis (HRM) is a rapid and efficient technique extensively employed as high-throughput mutation scanning method. The purpose of our study was to assess the specificity and sensitivity of HRM for BRCA1 and BRCA2 genes scanning. As a first step we estimate the ability of HRM for detection mutations in a set of 21 heterozygous samples harboring 8 different known BRCA1/BRCA2 variations, all samples had been preliminarily investigated by direct sequencing, and then we performed a blinded analysis by HRM in a set of 68 further sporadic samples of unknown genotype. All tested heterozygous BRCA1/BRCA2 variants were easily identified. However the HRM assay revealed further alteration that we initially had not searched (one unclassified variant). Furthermore, sequencing confirmed all the HRM detected mutations in the set of unknown samples, including homozygous changes, indicating that in this cohort, with the optimized assays, the mutations detections sensitivity and specificity were 100 %. HRM is a simple, rapid and efficient scanning method for known and unknown BRCA1/BRCA2 germline mutations. Consequently the method will allow for the economical screening of recurrent mutations in Tunisian population.

  13. A biolayer interferometry-based assay for rapid and highly sensitive detection of biowarfare agents.

    PubMed

    Mechaly, Adva; Cohen, Hila; Cohen, Ofer; Mazor, Ohad

    2016-08-01

    Biolayer interferometry (BLI) is an optical technique that uses fiber-optic biosensors for label-free real-time monitoring of protein-protein interactions. In this study, we coupled the advantages of the Octet Red BLI system (automation, fluidics-free, and on-line monitoring) with a signal enhancement step and developed a rapid and sensitive immunological-based method for detection of biowarfare agents. As a proof of concept, we chose to demonstrate the efficacy of this novel assay for the detection of agents representing two classes of biothreats, proteinaceous toxins, and bacterial pathogens: ricin, a lethal plant toxin, and the gram-negative bacterium Francisella tularensis, the causative agent of tularemia. The assay setup consisted of biotinylated antibodies immobilized to the biosensor coupled with alkaline phosphatase-labeled antibodies as the detection moiety to create nonsoluble substrate crystals that precipitate on the sensor surface, thereby inducing a significant wavelength interference. It was found that this BLI-based assay enables sensitive detection of these pathogens (detection limits of 10 pg/ml and 1 × 10(4) pfu/ml ricin and F. tularensis, respectively) within a very short time frame (17 min). Owing to its simplicity, this assay can be easily adapted to detect other analytes in general, and biowarfare agents in particular, in a rapid and sensitive manner. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Rapid identification of 11 human intestinal Lactobacillus species by multiplex PCR assays using group- and species-specific primers derived from the 16S-23S rRNA intergenic spacer region and its flanking 23S rRNA.

    PubMed

    Song, Y; Kato, N; Liu, C; Matsumiya, Y; Kato, H; Watanabe, K

    2000-06-15

    Rapid and reliable two-step multiplex polymerase chain reaction (PCR) assays were established to identify human intestinal lactobacilli; a multiplex PCR was used for grouping of lactobacilli with a mixture of group-specific primers followed by four multiplex PCR assays with four sorts of species-specific primer mixtures for identification at the species level. Primers used were designed from nucleotide sequences of the 16S-23S rRNA intergenic spacer region and its flanking 23S rRNA gene of members of the genus Lactobacillus which are commonly isolated from human stool specimens: Lactobacillus acidophilus, Lactobacillus crispatus, Lactobacillus delbrueckii (ssp. bulgaricus and ssp. lactis), Lactobacillus fermentum, Lactobacillus gasseri, Lactobacillus jensenii, Lactobacillus paracasei (ssp. paracasei and ssp. tolerans), Lactobacillus plantarum, Lactobacillus reuteri, Lactobacillus rhamnosus and Lactobacillus salivarius (ssp. salicinius and ssp. salivarius). The established two-step multiplex PCR assays were applied to the identification of 84 Lactobacillus strains isolated from human stool specimens and the PCR results were consistent with the results from the DNA-DNA hybridization assay. These results suggest that the multiplex PCR system established in this study is a simple, rapid and reliable method for the identification of common Lactobacillus isolates from human stool samples.

  15. Rapid detection of rifampin-resistant clinical isolates of Mycobacterium tuberculosis by reverse dot blot hybridization.

    PubMed

    Guo, Qian; Yu, Yan; Zhu, Yan Ling; Zhao, Xiu Qin; Liu, Zhi Guang; Zhang, Yuan Yuan; Li, Gui Lian; Wei, Jian Hao; Wu, Yi Mou; Wan, Kang Lin

    2015-01-01

    A PCR-reverse dot blot hybridization (RDBH) assay was developed for rapid detection of rpoB gene mutations in 'hot mutation region' of Mycobacterium tuberculosis (M. tuberculosis). 12 oligonucleotide probes based on the wild-type and mutant genotype rpoB sequences of M. tuberculosis were designed to screen the most frequent wild-type and mutant genotypes for diagnosing RIF resistance. 300 M. tuberculosis clinical isolates were detected by RDBH, conventional drug-susceptibility testing (DST) and DNA sequencing to evaluate the RDBH assay. The sensitivity and specificity of the RDBH assay were 91.2% (165/181) and 98.3% (117/119), respectively, as compared to DST. When compared with DNA sequencing, the accuracy, positive predictive value (PPV) and negative predictive value (NPV) of the RDBH assay were 97.7% (293/300), 98.2% (164/167), and 97.0% (129/133), respectively. Furthermore, the results indicated that the most common mutations were in codons 531 (48.6%), 526 (25.4%), 516 (8.8%), and 511 (6.6%), and the combinative mutation rate was 15 (8.3%). One and two strains of insertion and deletion were found among all strains, respectively. Our findings demonstrate that the RDBH assay is a rapid, simple and sensitive method for diagnosing RIF-resistant tuberculosis. Copyright © 2015 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  16. Rapid one-step whole blood C-reactive protein magnetic permeability immunoassay with monoclonal antibody conjugated nanoparticles as superparamagnetic labels and enhanced sedimentation.

    PubMed

    Ibraimi, Filiz; Kriz, Dario; Lu, Min; Hansson, Lars-Olof; Kriz, Kirstin

    2006-02-01

    A rapid (5.5 min) one-step whole blood C-reactive protein (CRP) magnetic permeability immunoassay utilizing monoclonal antibody conjugated dextran iron oxide nanoparticles (70 nm) as superparamagnetic labels and mixed fractions (1:1 ratio of 15-40 and 60 microm) of polyclonal anti-CRP conjugated silica microparticles for enhanced sedimentation is described. In this one-step assay procedure, a whole blood sample (4 microl) is applied to an assay glass vial, containing both antibody conjugates, and mixed for 30 s. The target analyte, CRP, forms a sandwich complex between the conjugated nanoparticles and microparticles, and, subsequently, the complex sediments under normal gravitation within 5 min to the bottom of the vial. The magnetic permeability increase of the sediment due to the presence of the complexed superparamagnetic nanoparticles is determined using an inductance-based transducer. Assayed patient whole blood samples were compared with the Abbott Diagnostics Architect reference method. A strong linear correlation was observed for the CRP concentration range 0-260 mg/l in whole blood (y=1.001x+0.42, R2=0.982, n=50). The CRP assay presented showed a limit of detection of 3 mg/l and a total imprecision (coefficient of variation) of 10.5%. On the basis of our observations, we propose a rapid, one-step, CRP assay for near-patient testing.

  17. Establishment of reverse transcription loop-mediated isothermal amplification for rapid detection and differentiation of canine distemper virus infected and vaccinated animals.

    PubMed

    Liu, Da-Fei; Liu, Chun-Guo; Tian, Jin; Jiang, Yi-Tong; Zhang, Xiao-Zhan; Chai, Hong-Liang; Yang, Tian-Kuo; Yin, Xiu-Chen; Zhang, Hong-Ying; Liu, Ming; Hua, Yu-Ping; Qu, Lian-Dong

    2015-06-01

    Although widespread vaccination against canine distemper virus (CDV) has been conducted for many decades, several canine distemper outbreaks in vaccinated animals have been reported frequently. In order to detect and differentiate the wild-type and vaccine strains of the CDV from the vaccinated animals, a novel reverse transcription loop-mediated isothermal amplification (RT-LAMP) method was developed. A set of four primers-two internal and two external-were designed to target the H gene for the specific detection of wild-type CDV variants. The CDV-H RT-LAMP assay rapidly amplified the target gene, within 60 min, using a water bath held at a constant temperature of 65°C. The assay was 100-fold more sensitive than conventional RT-PCR, with a detection limit of 10(-1)TCID50ml(-1). The system showed a preference for wild-type CDV, and exhibited less sensitivity to canine parvovirus, canine adenovirus type 1 and type 2, canine coronavirus, and canine parainfluenza virus. The assay was validated using 102 clinical samples obtained from vaccinated dog farms, and the results were comparable to a multiplex nested RT-PCR assay. The specific CDV-H RT-LAMP assay provides a simple, rapid, and sensitive tool for the detection of canines infected with wild-type CDV from canines vaccinated with attenuated vaccine. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. A new diatom growth inhibition assay using the XTT colorimetric method.

    PubMed

    Jiang, Weina; Akagi, Takuya; Suzuki, Hidekazu; Takimoto, Ayaka; Nagai, Hiroshi

    2016-01-01

    Marine biofouling, which leads to significant operational stress and economic damage on marine infrastructures, is a major problem in marine related industries. Currently, the most common way to avoid marine biofouling involves the use of biocidal products in surface coatings. However, the need for environmentally friendly antibiofouling compounds has increased rapidly with the recent global prohibition of harmful antifoulants, such as tributyltin (TBT). In particular, periphytic diatoms have been shown to contribute significantly to biofilms, which play an important role in biofouling. Therefore, inhibiting the proliferation of fouling diatoms is a very important step in the prevention of marine biofouling. In this study, we developed a new, rapid, accurate, and convenient growth inhibition assay using the XTT colorimetric method to prevent the growth of the fouling periphytic diatom, Nitzschia amabilis Hidek. Suzuki (replaced synonym, Nitzschia laevis Hustedt). The feasibility of this method was verified by determining the growth inhibition activities of two standard photosynthetic inhibitors, DCMU and CuSO4. However, neither inhibitor had any cytotoxic activities at the range of concentrations tested. Moreover, this method was applied by screening and purification of herbicidic but non-cytotoxic compounds from cyanobacteria extracts. Our results demonstrate the utility of this newly established growth inhibition assay for the identification of marine anti-biofouling compounds. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Rapid Quantitative Detection of Lactobacillus sakei in Meat and Fermented Sausages by Real-Time PCR

    PubMed Central

    Martín, Belén; Jofré, Anna; Garriga, Margarita; Pla, Maria; Aymerich, Teresa

    2006-01-01

    A quick and simple method for quantitative detection of Lactobacillus sakei in fermented sausages was successfully developed. It is based on Chelex-100-based DNA purification and real-time PCR enumeration using a TaqMan fluorescence probe. Primers and probes were designed in the L. sakei 16S-23S rRNA intergenic transcribed spacer region, and the assay was evaluated using L. sakei genomic DNA and an artificially inoculated sausage model. The detection limit of this technique was approximately 3 cells per reaction mixture using both purified DNA and the inoculated sausage model. The quantification limit was established at 30 cells per reaction mixture in both models. The assay was then applied to enumerate L. sakei in real samples, and the results were compared to the MRS agar count method followed by confirmation of the percentage of L. sakei colonies. The results obtained by real-time PCR were not statistically significantly different than those obtained by plate count on MRS agar (P > 0.05), showing a satisfactory agreement between both methods. Therefore, the real-time PCR assay developed can be considered a promising rapid alternative method for the quantification of L. sakei and evaluation of the implantation of starter strains of L. sakei in fermented sausages. PMID:16957227

  20. Rapid quantitative detection of Lactobacillus sakei in meat and fermented sausages by real-time PCR.

    PubMed

    Martín, Belén; Jofré, Anna; Garriga, Margarita; Pla, Maria; Aymerich, Teresa

    2006-09-01

    A quick and simple method for quantitative detection of Lactobacillus sakei in fermented sausages was successfully developed. It is based on Chelex-100-based DNA purification and real-time PCR enumeration using a TaqMan fluorescence probe. Primers and probes were designed in the L. sakei 16S-23S rRNA intergenic transcribed spacer region, and the assay was evaluated using L. sakei genomic DNA and an artificially inoculated sausage model. The detection limit of this technique was approximately 3 cells per reaction mixture using both purified DNA and the inoculated sausage model. The quantification limit was established at 30 cells per reaction mixture in both models. The assay was then applied to enumerate L. sakei in real samples, and the results were compared to the MRS agar count method followed by confirmation of the percentage of L. sakei colonies. The results obtained by real-time PCR were not statistically significantly different than those obtained by plate count on MRS agar (P > 0.05), showing a satisfactory agreement between both methods. Therefore, the real-time PCR assay developed can be considered a promising rapid alternative method for the quantification of L. sakei and evaluation of the implantation of starter strains of L. sakei in fermented sausages.

  1. Evaluation of a new T2 Magnetic Resonance assay for rapid detection of emergent fungal pathogen Candida auris on clinical skin swab samples.

    PubMed

    Sexton, D Joseph; Bentz, Meghan L; Welsh, Rory M; Litvintseva, Anastasia P

    2018-06-25

    Candida auris is a multidrug-resistant pathogenic yeast whose recent emergence is of increasing public-health concern. C. auris can colonize multiple body sites, including patients' skin, and survive for weeks in the healthcare environment, facilitating patient-to-patient transmission and fueling healthcare-associated outbreaks. Rapid and accurate detection of C. auris colonization is essential for timely implementation of infection control measures and prevent transmission. Currently, axilla/groin composite swabs, used to assess colonization status, are processed using a culture-based method that is sensitive and specific but requires 14 days. This delay limits the opportunity to respond and highlights the need for a faster alternative. The culture-independent T2 Magnetic Resonance (T2MR) system is a rapid diagnostic platform shown to detect target pathogens of interest from unprocessed blood samples in <5 hours. In this study, a new C. auris-specific T2 assay was evaluated for screening of the skin surveillance samples. Inclusivity and limit of detection of the T2 C. auris assay were assessed with spiked samples in a representative skin flora background. The T2 C. auris assay recognized isolates from each of the 4 known clades of C. auris and consistently detected cells at 5 CFU/mL. Finally, 89 clinical axilla/groin swab samples were processed with the T2 C. auris assay. The culture-based diagnostic assay was used as a gold standard to determine performance statistics including sensitivity (0.89) and specificity (0.98). Overall, the T2 C. auris assay performed well as a rapid diagnostic and could help expedite the detection of C. auris in patient skin swabs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  2. Application of firefly luciferase assay for adenosine triphosphate (ATP) to antimicrobial drug sensitivity testing

    NASA Technical Reports Server (NTRS)

    Picciolo, G. L.; Tuttle, S. A.; Schrock, C. G.; Deming, J. W.; Barza, M. J.; Wienstein, L.; Chappelle, E. W.

    1977-01-01

    The development of a rapid method for determining microbial susceptibilities to antibiotics using the firefly luciferase assay for adenosine triphosphate (ATP) is documented. The reduction of bacterial ATP by an antimicrobial agent was determined to be a valid measure of drug effect in most cases. The effect of 12 antibiotics on 8 different bacterial species gave a 94 percent correlation with the standard Kirby-Buer-Agar disc diffusion method. A 93 percent correlation was obtained when the ATP assay method was applied directly to 50 urine specimens from patients with urinary tract infections. Urine samples were centrifuged first to that bacterial pellets could be suspended in broth. No primary isolation or subculturing was required. Mixed cultures in which one species was predominant gave accurate results for the most abundant organism. Since the method is based on an increase in bacterial ATP with time, the presence of leukocytes did not interfere with the interpretation of results. Both the incubation procedure and the ATP assays are compatible with automation.

  3. Development of a human-specific B. thetaiotaomicron IMS ...

    EPA Pesticide Factsheets

    Immunomagnetic separation/adenosine triphosphate (IMS/ATP) assays utilize paramagnetic beads and target-specific antibodies to isolate target organisms. Following isolation, adenosine tri-phosphate (ATP) is extracted from the target population and quantified. An inversely-coupled (Inv-IMS/ATP)assay for detection of Bacteroides thetaiotaomicron was developed and applied for rapid detection of human-associated fecal contamination in surface waters in Baja California. Specificity of the assay was tested against challenge solutions of varying concentrations of dog, gull, horse and chicken feces, and a field validation survey of coastal and WWTP effluent water quality in Rosarito and Enseneda, Baja California was conducted. Inv IMS/ATP measurements made shown to be specific and sensitive to human fecal contamination. At test concentrations of less than 1000 MPN ENT/100 mL, sensitivity and specificity of the assay both exceeded 80%. Moreover, the Inv-IMS/ATP assay yielded measurements of viable B. thetaiotaomicron that were comparable to the HF183 human marker in complex surface waters impacted with both wastewater and runoff, and the Inv-IMS/ATP assay was able to effectively differentiate between surface waters impacted with adequately and inadequately treated wastewater. The Inv-IMS/ATP assays shows promise for rapid evaluation of recreational water quality in areas where access to more expensive methods is limited and in areas where water quality in unpredicta

  4. Evaluation and comparison of rapid methods for the detection of Salmonella in naturally contaminated pine nuts using different pre enrichment media.

    PubMed

    Wang, Hua; Gill, Vikas S; Cheng, Chorng-Ming; Gonzalez-Escalona, Narjol; Irvin, Kari A; Zheng, Jie; Bell, Rebecca L; Jacobson, Andrew P; Hammack, Thomas S

    2015-04-01

    Foodborne outbreaks, involving pine nuts and peanut butter, illustrate the need to rapidly detect Salmonella in low moisture foods. However, the current Bacteriological Analytical Manual (BAM) culture method for Salmonella, using lactose broth (LB) as a pre enrichment medium, has not reliably supported real-time quantitative PCR (qPCR) assays for certain foods. We evaluated two qPCR assays in LB and four other pre enrichment media: buffered peptone water (BPW), modified BPW (mBPW), Universal Pre enrichment broth (UPB), and BAX(®) MP media to detect Salmonella in naturally-contaminated pine nuts (2011 outbreak). A four-way comparison among culture method, Pathatrix(®) Auto, VIDAS(®) Easy SLM, and qPCR was conducted. Automated DNA extraction techniques were compared with manual extraction methods (boiling or InstaGene™). There were no significant differences (P > 0.05) among the five pre enrichment media for pine nuts using the culture method. While both qPCR assays produced significantly (P ≤ 0.05) higher false negatives in 24 h pre enriched LB than in the other four media, they were as sensitive as the culture method in BPW, mBPW, UPB, and BAX media. The VIDAS Easy and qPCR were equivalent; Pathatrix was the least effective method. The Automatic PrepSEQ™ DNA extraction, using 1000 μL of pre enrichment, was as effective as manual extraction methods. Published by Elsevier Ltd.

  5. Rapid detection of infectious bovine Rhinotracheitis virus using recombinase polymerase amplification assays.

    PubMed

    Hou, Peili; Wang, Hongmei; Zhao, Guimin; He, Chengqiang; He, Hongbin

    2017-12-13

    Infectious bovine rhinotracheitis virus (IBRV) is a major pathogen in cattle and has led to significant economic losses to the dairy industry worldwide, and therefore a more optimal method for the rapid diagnosis of IBRV infection is highly needed. In this study, we described the development of a lateral flow dipstrip (LFD) of isothermal recombinase polymerase amplification (RPA) method for rapid detection of IBRV. Distinct regions were selected as a candidate target for designing the LFD-RPA primers and probes. The analytical sensitivity of the RPA assay was determined using ten-fold serially diluted IBRV DNA. The specificity of the assay was assessed with other viral pathogens of cattle with similar clinic and other herpesviruses. The clinical performance was evaluated by testing 106 acute-phase high fever clinical specimens. RPA primers and probe were designed to target the specific conserved UL52 region fragment of IBRV. The detection could be completed at a constant temperature of 38 °C for 25 min, and the amplification products were easily visualized on a simple LFD. The detection limit of this assay was 5 copies per reaction of IBRV DNA and there was no cross-reactivity with other viruses causing bovine gastrointestinal and respiratory infections or other herpesviruses. The assay performance on acute-phase high fever clinical samples collected from cattle with no vaccine against IBRV, which were suspected to be infected with IBRV, was validated by detecting 24 fecal, 36 blood, 38 nasal swab and 8 tissue specimens, and compared with SYBR Green I based real-time PCR. The coincidence between IBRV LFD-RPA and real-time PCR was 100%. IBRV LFD-RPA was fast and much easier to serve as an alternative to the common measures used for IBRV diagnosis, as there is reduction in the use of instruments for identification of the infected animals. In addition, this assay may be the potential candidate to be used as point-of-care diagnostics in the field.

  6. Rapid identification of ascomycetous yeasts from clinical specimens by a molecular method based on flow cytometry and comparison with identifications from phenotypic assays.

    PubMed

    Page, Brent T; Shields, Christine E; Merz, William G; Kurtzman, Cletus P

    2006-09-01

    This study was designed to compare the identification of ascomycetous yeasts recovered from clinical specimens by using phenotypic assays (PA) and a molecular flow cytometric (FC) method. Large-subunit rRNA domains 1 and 2 (D1/D2) gene sequence analysis was also performed and served as the reference for correct strain identification. A panel of 88 clinical isolates was tested that included representatives of nine commonly encountered species and six infrequently encountered species. The PA included germ tube production, fermentation of seven carbohydrates, morphology on corn meal agar, urease and phenoloxidase activities, and carbohydrate assimilation tests when needed. The FC method (Luminex) employed species-specific oligonucleotides attached to polystyrene beads, which were hybridized with D1/D2 amplicons from the unidentified isolates. The PA identified 81 of 88 strains correctly but misidentified 4 of Candida dubliniensis, 1 of C. bovina, 1 of C. palmioleophila, and 1 of C. bracarensis. The FC method correctly identified 79 of 88 strains and did not misidentify any isolate but did not identify nine isolates because oligonucleotide probes were not available in the current library. The FC assay takes approximately 5 h, whereas the PA takes from 2 h to 5 days for identification. In conclusion, PA did well with the commonly encountered species, was not accurate for uncommon species, and takes significantly longer than the FC method. These data strongly support the potential of FC technology for rapid and accurate identification of medically important yeasts. With the introduction of new antifungals, rapid, accurate identification of pathogenic yeasts is more important than ever for guiding antifungal chemotherapy.

  7. Use of a Rapid Ethylene Glycol Assay: a 4-Year Retrospective Study at an Academic Medical Center.

    PubMed

    Rooney, Sydney L; Ehlers, Alexandra; Morris, Cory; Drees, Denny; Davis, Scott R; Kulhavy, Jeff; Krasowski, Matthew D

    2016-06-01

    Ethylene glycol (EG) is a common cause of toxic ingestions. Gas chromatography (GC)-based laboratory assays are the gold standard for diagnosing EG intoxication. However, GC requires specialized instrumentation and technical expertise that limits feasibility for many clinical laboratories. The objective of this retrospective study was to determine the utility of incorporating a rapid EG assay for management of cases with suspected EG poisoning. The University of Iowa Hospitals and Clinics core clinical laboratory adapted a veterinary EG assay (Catachem, Inc.) for the Roche Diagnostics cobas 8000 c502 analyzer and incorporated this assay in an osmolal gap-based algorithm for potential toxic alcohol/glycol ingestions. The main limitation is that high concentrations of propylene glycol (PG), while readily identifiable by reaction rate kinetics, can interfere with EG measurement. The clinical laboratory had the ability to perform GC for EG and PG, if needed. A total of 222 rapid EG and 24 EG/PG GC analyses were documented in 106 patient encounters. Of ten confirmed EG ingestions, eight cases were managed entirely with the rapid EG assay. PG interference was evident in 25 samples, leading to 8 GC analyses to rule out the presence of EG. Chart review of cases with negative rapid EG assay results showed no evidence of false negatives. The results of this study highlight the use of incorporating a rapid EG assay for the diagnosis and management of suspected EG toxicity by decreasing the reliance on GC. Future improvements would involve rapid EG assays that completely avoid interference by PG.

  8. Use of Molecular Methods for the Rapid Mass Detection of Schistosoma mansoni (Platyhelminthes: Trematoda) in Biomphalaria spp. (Gastropoda: Planorbidae)

    PubMed Central

    Jannotti-Passos, Liana Konovaloffi; Dos Santos Carvalho, Omar

    2017-01-01

    The low stringency-polymerase chain reaction (LS-PCR) and loop-mediated isothermal amplification (LAMP) assays were used to detect the presence of S. mansoni DNA in (1) Brazilian intermediate hosts (Biomphalaria glabrata, B. straminea, and B. tenagophila) with patent S. mansoni infections, (2) B. glabrata snails with prepatent S. mansoni infections, (3) various mixtures of infected and noninfected snails; and (4) snails infected with other trematode species. The assays showed high sensitivity and specificity and could detect S. mansoni DNA when one positive snail was included in a pool of 1,000 negative specimens of Biomphalaria. These molecular approaches can provide a low-cost, effective, and rapid method for detecting the presence of S. mansoni in pooled samples of field-collected Biomphalaria. These assays should aid mapping of transmission sites in endemic areas, especially in low prevalence regions and improve schistosomiasis surveillance. It will be a useful tool to monitor low infection rates of snails in areas where control interventions are leading towards the elimination of schistosomiasis. PMID:28246533

  9. New Method for Simultaneous Species-Specific Identification of Equine Strongyles (Nematoda, Strongylida) by Reverse Line Blot Hybridization▿

    PubMed Central

    Traversa, Donato; Iorio, Raffaella; Klei, Thomas R.; Kharchenko, Vitaliy A.; Gawor, Jakub; Otranto, Domenico; Sparagano, Olivier A. E.

    2007-01-01

    The ability of a reverse line blot (RLB) assay to identify 13 common species of equine small strongyles (cyathostomins) and to discriminate them from three Strongylus spp. (large strongyles) was demonstrated. The assay relied on the specific hybridization of PCR-amplified intergenic spacer DNA fragments of the nuclear ribosomal DNA to membrane-bound species-specific probes. All cyathostomins examined were unequivocally identified and simultaneously discriminated from each other and from three large strongyles (Strongylus edentatus, Strongylus equinus, and Strongylus vulgaris). This assay will enable the accurate and rapid identification of equine cyathostomins irrespective of their life cycle stage, opening important avenues for a better understanding of their biology and epidemiology and of the pathogenesis of cyathostomin-associated disease. In particular, this RLB method promises to be a powerful diagnostic tool to determine the roles of individual species in the pathogenesis of mixed infections and to elucidate some aspects of cyathostominosis. Also, it could represent a basic step toward the development of a rapid and simple molecular test for the early detection of drug-resistant genotypes of horse strongyle species. PMID:17626168

  10. A double-label time-resolved fluorescent strip for rapidly quantitative detection of carbofuran residues in agro-products.

    PubMed

    Zhang, Qi; Qu, Qiaoyu; Chen, Shanshan; Liu, Xiaowei; Li, Peiwu

    2017-09-15

    A rapid and quantitative time-resolved fluorescent immunochromatographic assay (TRFICA) for detecting carbofuran residues in agro-products was reported in this paper. This assay was developed based on double-label immunoprobes, one of which was a carbofuran-specific antibody coupled with europium microbeads for the test (T) line signal while the other was mouse IgG coupled with europium microbeads for the control (C) line signal. Quantitative relationships between carbofuran concentrations and T/C ratios were established to determine the analyte concentration. To increase assay accuracy, four standard curves were established for the agro-products (green bean, cabbage, apple, and pear). The limits of detection (LODs) ranged from 0.04 to 0.76mgL -1 . The spiked recoveries of carbofuran in the agro-products were in the range of 81-103%, which was in good agreement with a standard HPLC method. Therefore, we provided a new and reliable method for determination of N-methylcarbamate pesticide carbofuran residues in agro-products including vegetables and fruits. Copyright © 2017. Published by Elsevier Ltd.

  11. Rapid detection of the CYP2A6*12 hybrid allele by Pyrosequencing technology.

    PubMed

    Koontz, Deborah A; Huckins, Jacqueline J; Spencer, Antonina; Gallagher, Margaret L

    2009-08-24

    Identification of CYP2A6 alleles associated with reduced enzyme activity is important in the study of inter-individual differences in drug metabolism. CYP2A6*12 is a hybrid allele that results from unequal crossover between CYP2A6 and CYP2A7 genes. The 5' regulatory region and exons 1-2 are derived from CYP2A7, and exons 3-9 are derived from CYP2A6. Conventional methods for detection of CYP2A6*12 consist of two-step PCR protocols that are laborious and unsuitable for high-throughput genotyping. We developed a rapid and accurate method to detect the CYP2A6*12 allele by Pyrosequencing technology. A single set of PCR primers was designed to specifically amplify both the CYP2A6*1 wild-type allele and the CYP2A6*12 hybrid allele. An internal Pyrosequencing primer was used to generate allele-specific sequence information, which detected homozygous wild-type, heterozygous hybrid, and homozygous hybrid alleles. We first validated the assay on 104 DNA samples that were also genotyped by conventional two-step PCR and by cycle sequencing. CYP2A6*12 allele frequencies were then determined using the Pyrosequencing assay on 181 multi-ethnic DNA samples from subjects of African American, European Caucasian, Pacific Rim, and Hispanic descent. Finally, we streamlined the Pyrosequencing assay by integrating liquid handling robotics into the workflow. Pyrosequencing results demonstrated 100% concordance with conventional two-step PCR and cycle sequencing methods. Allele frequency data showed slightly higher prevalence of the CYP2A6*12 allele in European Caucasians and Hispanics. This Pyrosequencing assay proved to be a simple, rapid, and accurate alternative to conventional methods, which can be easily adapted to the needs of higher-throughput studies.

  12. Development of molecular methods for the rapid detection of antibiotic susceptibility of Mycoplasma bovis.

    PubMed

    Sulyok, Kinga M; Bekő, Katinka; Kreizinger, Zsuzsa; Wehmann, Enikő; Jerzsele, Ákos; Rónai, Zsuzsanna; Turcsányi, Ibolya; Makrai, László; Szeredi, Levente; Jánosi, Szilárd; Nagy, Sára Ágnes; Gyuranecz, Miklós

    2018-01-01

    Determining the antibiotic susceptibility profile of Mycoplasma bovis isolates in vitro provides the basis for the appropriate choice of antibiotics in the therapy. Traditionally, the antibiotic susceptibility examination of mycoplasmas is technically demanding, time-consuming and rarely performed in diagnostic laboratories. The aim of the present study was to develop rapid molecular assays to determine mutations responsible for elevated minimal inhibitory concentrations (MICs) to fluoroquinolones, tetracyclines, aminocyclitols, macrolides, lincosamides, phenicols and pleuromutilins in M. bovis. The nine mismatch amplification mutation assays (MAMA) and seven high resolution melt (HRM) tests designed in the present study enable the simultaneous detection of these genetic markers. The sensitivity of the assays varied between 10 2 -10 5 copy numbers/reaction. Cross-reactions with other mycoplasmas occurring in cattle were detected in assays targeting universal regions (e.g. 16S rRNA). Nevertheless, results of the novel method were in accordance with sequence and MICs data of the M. bovis pure cultures. Also, the tests of clinical samples containing high amount of M. bovis DNA were congruent even in the presence of other Mycoplasma spp. The presented method is highly cost-effective and can provide an antibiogram to 12 antibiotics in approximately 3-4 days when previous isolation of M. bovis is applied. In order to assure the proper identification of the genetic markers at issue, the regions examined by the MAMA and HRM tests are overlapping. In conclusion, the developed assays have potential to be used in routine diagnostics for the detection of antibiotic susceptibility in M. bovis. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Rapid optical determination of β-lactamase and antibiotic activity

    PubMed Central

    2014-01-01

    Background The absence of rapid tests evaluating antibiotic susceptibility results in the empirical prescription of antibiotics. This can lead to treatment failures due to escalating antibiotic resistance, and also furthers the emergence of drug-resistant bacteria. This study reports a rapid optical method to detect β-lactamase and thereby assess activity of β-lactam antibiotics, which could provide an approach for targeted prescription of antibiotics. The methodology is centred on a fluorescence quenching based probe (β-LEAF – β-Lactamase Enzyme Activated Fluorophore) that mimics the structure of β-lactam antibiotics. Results The β-LEAF assay was performed for rapid determination of β-lactamase production and activity of β-lactam antibiotic (cefazolin) on a panel of Staphylococcus aureus ATCC strains and clinical isolates. Four of the clinical isolates were determined to be lactamase producers, with the capacity to inactivate cefazolin, out of the twenty-five isolates tested. These results were compared against gold standard methods, nitrocefin disk test for β-lactamase detection and disk diffusion for antibiotic susceptibility, showing results to be largely consistent. Furthermore, in the sub-set of β-lactamase producers, it was demonstrated and validated that multiple antibiotics (cefazolin, cefoxitin, cefepime) could be assessed simultaneously to predict the antibiotic that would be most active for a given bacterial isolate. Conclusions The study establishes the rapid β-LEAF assay for β-lactamase detection and prediction of antibiotic activity using S. aureus clinical isolates. Although the focus in the current study is β-lactamase-based resistance, the overall approach represents a broad diagnostic platform. In the long-term, these studies form the basis for the development of assays utilizing a broader variety of targets, pathogens and drugs. PMID:24708478

  14. Clinical Application of Picodroplet Digital PCR Technology for Rapid Detection of EGFR T790M in Next-Generation Sequencing Libraries and DNA from Limited Tumor Samples.

    PubMed

    Borsu, Laetitia; Intrieri, Julie; Thampi, Linta; Yu, Helena; Riely, Gregory; Nafa, Khedoudja; Chandramohan, Raghu; Ladanyi, Marc; Arcila, Maria E

    2016-11-01

    Although next-generation sequencing (NGS) is a robust technology for comprehensive assessment of EGFR-mutant lung adenocarcinomas with acquired resistance to tyrosine kinase inhibitors, it may not provide sufficiently rapid and sensitive detection of the EGFR T790M mutation, the most clinically relevant resistance biomarker. Here, we describe a digital PCR (dPCR) assay for rapid T790M detection on aliquots of NGS libraries prepared for comprehensive profiling, fully maximizing broad genomic analysis on limited samples. Tumor DNAs from patients with EGFR-mutant lung adenocarcinomas and acquired resistance to epidermal growth factor receptor inhibitors were prepared for Memorial Sloan-Kettering-Integrated Mutation Profiling of Actionable Cancer Targets sequencing, a hybrid capture-based assay interrogating 410 cancer-related genes. Precapture library aliquots were used for rapid EGFR T790M testing by dPCR, and results were compared with NGS and locked nucleic acid-PCR Sanger sequencing (reference high sensitivity method). Seventy resistance samples showed 99% concordance with the reference high sensitivity method in accuracy studies. Input as low as 2.5 ng provided a sensitivity of 1% and improved further with increasing DNA input. dPCR on libraries required less DNA and showed better performance than direct genomic DNA. dPCR on NGS libraries is a robust and rapid approach to EGFR T790M testing, allowing most economical utilization of limited material for comprehensive assessment. The same assay can also be performed directly on any limited DNA source and cell-free DNA. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  15. Rapid methods for the detection of foodborne bacterial pathogens: principles, applications, advantages and limitations

    PubMed Central

    Law, Jodi Woan-Fei; Ab Mutalib, Nurul-Syakima; Chan, Kok-Gan; Lee, Learn-Han

    2015-01-01

    The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR), multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP) and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases. PMID:25628612

  16. A novel fluorescence-based assay for the rapid detection and quantification of cellular deoxyribonucleoside triphosphates

    PubMed Central

    Wilson, Peter M.; LaBonte, Melissa J.; Russell, Jared; Louie, Stan; Ghobrial, Andrew A.; Ladner, Robert D.

    2011-01-01

    Current methods for measuring deoxyribonucleoside triphosphates (dNTPs) employ reagent and labor-intensive assays utilizing radioisotopes in DNA polymerase-based assays and/or chromatography-based approaches. We have developed a rapid and sensitive 96-well fluorescence-based assay to quantify cellular dNTPs utilizing a standard real-time PCR thermocycler. This assay relies on the principle that incorporation of a limiting dNTP is required for primer-extension and Taq polymerase-mediated 5–3′ exonuclease hydrolysis of a dual-quenched fluorophore-labeled probe resulting in fluorescence. The concentration of limiting dNTP is directly proportional to the fluorescence generated. The assay demonstrated excellent linearity (R2 > 0.99) and can be modified to detect between ∼0.5 and 100 pmol of dNTP. The limits of detection (LOD) and quantification (LOQ) for all dNTPs were defined as <0.77 and <1.3 pmol, respectively. The intra-assay and inter-assay variation coefficients were determined to be <4.6% and <10%, respectively with an accuracy of 100 ± 15% for all dNTPs. The assay quantified intracellular dNTPs with similar results obtained from a validated LC–MS/MS approach and successfully measured quantitative differences in dNTP pools in human cancer cells treated with inhibitors of thymidylate metabolism. This assay has important application in research that investigates the influence of pathological conditions or pharmacological agents on dNTP biosynthesis and regulation. PMID:21576234

  17. Rapid and simple method by combining FTA™ card DNA extraction with two set multiplex PCR for simultaneous detection of non-O157 Shiga toxin-producing Escherichia coli strains and virulence genes in food samples.

    PubMed

    Kim, S A; Park, S H; Lee, S I; Ricke, S C

    2017-12-01

    The aim of this research was to optimize two multiplex polymerase chain reaction (PCR) assays that could simultaneously detect six non-O157 Shiga toxin-producing Escherichia coli (STEC) as well as the three virulence genes. We also investigated the potential of combining the FTA™ card-based DNA extraction with the multiplex PCR assays. Two multiplex PCR assays were optimized using six primer pairs for each non-O157 STEC serogroup and three primer pairs for virulence genes respectively. Each STEC strain specific primer pair only amplified 155, 238, 321, 438, 587 and 750 bp product for O26, O45, O103, O111, O121 and O145 respectively. Three virulence genes were successfully multiplexed: 375 bp for eae, 655 bp for stx1 and 477 bp for stx2. When two multiplex PCR assays were validated with ground beef samples, distinctive bands were also successfully produced. Since the two multiplex PCR examined here can be conducted under the same PCR conditions, the six non-O157 STEC and their virulence genes could be concurrently detected with one run on the thermocycler. In addition, all bands clearly appeared to be amplified by FTA card DNA extraction in the multiplex PCR assay from the ground beef sample, suggesting that an FTA card could be a viable sampling approach for rapid and simple DNA extraction to reduce time and labour and therefore may have practical use for the food industry. Two multiplex polymerase chain reaction (PCR) assays were optimized for discrimination of six non-O157 Shiga toxin-producing Escherichia coli (STEC) and identification of their major virulence genes within a single reaction, simultaneously. This study also determined the successful ability of the FTA™ card as an alternative to commercial DNA extraction method for conducting multiplex STEC PCR assays. The FTA™ card combined with multiplex PCR holds promise for the food industry by offering a simple and rapid DNA sample method for reducing time, cost and labour for detection of STEC in food and environmental samples. © 2017 The Society for Applied Microbiology.

  18. Practical direct plaque assay for coliphages in 100-ml samples of drinking water.

    PubMed Central

    Grabow, W O; Coubrough, P

    1986-01-01

    A practical single-agar-layer plaque assay for the direct detection of coliphages in 100-ml samples of water was designed and evaluated. With this assay a 100-ml sample of water, an agar medium containing divalent cations, and the host Escherichia coli C (ATCC 13706) were mixed in a single container, and the mixture was plated on 10 14-cm-diameter petri dishes. It was more sensitive, reliable, and accurate than various other methods and proved rapid, simple, and economic. PMID:3532952

  19. Comparison of five assays for detection of Clostridium difficile toxin.

    PubMed

    Chapin, Kimberle C; Dickenson, Roberta A; Wu, Fongman; Andrea, Sarah B

    2011-07-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  20. Comparison of Five Assays for Detection of Clostridium difficile Toxin

    PubMed Central

    Chapin, Kimberle C.; Dickenson, Roberta A.; Wu, Fongman; Andrea, Sarah B.

    2011-01-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. PMID:21704273

  1. Rapid Differentiation and In Situ Detection of 16 Sourdough Lactobacillus Species by Multiplex PCR

    PubMed Central

    Settanni, Luca; van Sinderen, Douwe; Rossi, Jone; Corsetti, Aldo

    2005-01-01

    A two-step multiplex PCR-based method was designed for the rapid detection of 16 species of lactobacilli known to be commonly present in sourdough. The first step of multiplex PCR was developed with a mixture of group-specific primers, while the second step included three multiplex PCR assays with a mixture of species-specific primers. Primers were derived from sequences that specify the 16S rRNA, the 16S-23S rRNA intergenic spacer region, and part of the 23S rRNA gene. The primer pairs designed were shown to exclusively amplify the targeted rrn operon fragment of the corresponding species. Due to the reliability of simultaneously identifying Lactobacillus plantarum, Lactobacillus pentosus, and Lactobacillus paraplantarum, a previously described multiplex PCR method employing recA gene-derived primers was included in the multiplex PCR system. The combination of a newly developed, quick bacterial DNA extraction method from sourdough and this multiplex PCR assay allows the rapid in situ detection of several sourdough-associated lactobacilli, including the recently described species Lactobacillus rossii, and thus represents a very useful alternative to culture-based methodologies. PMID:15933001

  2. Assaying Auxin Receptor Activity Using SPR Assays with F-Box Proteins and Aux/IAA Degrons.

    PubMed

    Quareshy, Mussa; Uzunova, Veselina; Prusinska, Justyna M; Napier, Richard M

    2017-01-01

    The identification of TIR1 as an auxin receptor combined with advanced biophysical instrumentation has led to the development of real-time activity assays for auxins. Traditionally, molecules have been assessed for auxinic activity using bioassays, and agrochemical compound discovery continues to be based on "spray and pray" technologies. Here, we describe the methodology behind an SPR-based assay that uses TIR1 and related F-box proteins with surface plasmon resonance spectrometry for rapid compound screening. In addition, methods for collecting kinetic binding data and data processing are given so that they may support programs for rational design of novel auxin ligands.

  3. Comprehensive Multiplex One-Step Real-Time TaqMan qRT-PCR Assays for Detection and Quantification of Hemorrhagic Fever Viruses

    PubMed Central

    Li, Jiandong; Qu, Jing; He, Chengcheng; Zhang, Shuo; Li, Chuan; Zhang, Quanfu; Liang, Mifang; Li, Dexin

    2014-01-01

    Background Viral hemorrhagic fevers (VHFs) are a group of animal and human illnesses that are mostly caused by several distinct families of viruses including bunyaviruses, flaviviruses, filoviruses and arenaviruses. Although specific signs and symptoms vary by the type of VHF, initial signs and symptoms are very similar. Therefore rapid immunologic and molecular tools for differential diagnosis of hemorrhagic fever viruses (HFVs) are important for effective case management and control of the spread of VHFs. Real-time quantitative reverse transcriptase-polymerase chain reaction (qRT-PCR) assay is one of the reliable and desirable methods for specific detection and quantification of virus load. Multiplex PCR assay has the potential to produce considerable savings in time and resources in the laboratory detection. Results Primers/probe sets were designed based on appropriate specific genes for each of 28 HFVs which nearly covered all the HFVs, and identified with good specificity and sensitivity using monoplex assays. Seven groups of multiplex one-step real-time qRT-PCR assays in a universal experimental system were then developed by combining all primers/probe sets into 4-plex reactions and evaluated with serial dilutions of synthesized viral RNAs. For all the multiplex assays, no cross-reactivity with other HFVs was observed, and the limits of detection were mainly between 45 and 150 copies/PCR. The reproducibility was satisfactory, since the coefficient of variation of Ct values were all less than 5% in each dilution of synthesized viral RNAs for both intra-assays and inter-assays. Evaluation of the method with available clinical serum samples collected from HFRS patients, SFTS patients and Dengue fever patients showed high sensitivity and specificity of the related multiplex assays on the clinical specimens. Conclusions Overall, the comprehensive multiplex one-step real-time qRT-PCR assays were established in this study, and proved to be specific, sensitive, stable and easy to serve as a useful tool for rapid detection of HFVs. PMID:24752452

  4. Rapid QPCR-based assay for fecal Bacteroides spp. as a tool for assessing fecal contamination in recreational waters.

    PubMed

    Converse, Reagan R; Blackwood, A Denene; Kirs, Marek; Griffith, John F; Noble, Rachel T

    2009-11-01

    Concentrations of fecal indicator bacteria (FIB; e.g. Escherichia coli, and Enterococcus sp.) can only be used in limited ways for determining the source of fecal contamination in recreational waters because they cannot distinguish human from non-human fecal contamination. Several Bacteroides spp. have been suggested as potential alternative indicators. We have developed a rapid, culture-independent method for quantifying fecal Bacteroides spp. using quantitative PCR (QPCR) targeting the 16S rRNA gene. The assay specifically targets and quantifies the most common human Bacteroides spp. The details of the method are presented, including analyses of a wide range of fecal samples from different organisms. Specificity and performance of the QPCR assay were also tested via a laboratory experiment where human sewage and gull guano were inoculated into a range of environmental water samples. Concentrations of fecal Bacteroides spp., total Enterococcus sp., Enterococcus faecium, Enterococcus faecalis, and Enterococcus casseliflavus were measured using QPCR, and total Enterococcus sp. and E. coli were quantified by membrane filtration (MF). Samples spiked with gull guano were highly concentrated with total Enterococcus sp., E. coli, E. faecalis, and E. casseliflavus, demonstrating that these indicators are prominent in animal feces. On the other hand, fecal Bacteroides spp. concentrations were high in samples containing sewage and were relatively low in samples spiked with gull guano. Sensitivity and specificity results suggest that the rapid fecal Bacteroides spp. QPCR assay may be a useful tool to effectively predict the presence and concentration of human-specific fecal pollution.

  5. Lack of concordance between a rapid bedside and conventional laboratory method of cardiac troponin testing: impact on risk stratification of patients suspected of acute coronary syndrome.

    PubMed

    Cramer, G Etienne; Kievit, Peter C; Brouwer, Marc A; de Keijzer, Marinus H; Luijten, Hans E; Verheugt, Freek W A

    2007-06-01

    This study was designed to test the usefulness of a bedside assay as compared to a laboratory method of troponin testing to predict adverse cardiac outcome of chest pain patients. We studied 358 ER visits of patients suspected of a non ST-elevation acute coronary syndrome. cTnI (Immulite, DPC) on a lab analyser and cTnT (Cardiac Reader, Roche) at bedside were measured at baseline. The between-assay level of concordance, reporting turnaround times and clinical outcomes during 180 days of follow-up were assessed. Death and myocardial infarction were then evaluated according to troponin result, either concordant negative, discordant or concordant positive. Discordance occurred in 11.4% (41/358) of cases. The proportion of patients with a positive cTnI and negative cTnT result (8.9%) versus the reverse (2.5%) differed significantly (p<0.001). The median time gained using the rapid test was 72 min. The rate of death and/or MI was 25% (10/40) among patients with discordant results as compared to 7.5% (17/228) with a concordant negative result (p<0.001). All patients from the discordant group with an event had a positive cTnI result, while cTnT was negative. Patients with a discordant reading were at high risk of adverse cardiac outcome, which was only identified by the laboratory cTnI assay. Markedly, the use of the rapid assay saved time at the expense of clinical sensitivity.

  6. Molecular Identification of an Invasive Wood-Boring Insect Lyctus brunneus (Coleoptera: Bostrichidae: Lyctinae) Using Frass by Loop-Mediated Isothermal Amplification and Nested PCR Assays.

    PubMed

    Ide, Tatsuya; Kanzaki, Natsumi; Ohmura, Wakako; Okabe, Kimiko

    2016-03-27

    Lyctus brunneus(Stephens) is one of the most destructive and worldwide invasive pests of seasoned woods for wooden products. This and other pestLyctusspecies have had their distribution expanded by international and domestic human transportation of infested wood and wood products. Rapid detection and accurate identification ofLyctusspecies are effective tools for helping to eradicate them in new introduction sites. The accurate species-level identification of adults requires expert knowledge about their morphology. However, it takes much time and effort to recover suitable adult specimens because they are borers inside wood. Frass ofLyctusspecies can easily be detected and recovered in and around infested wood. Thus, frass was tested to see if it was a suitable sample to allow development of a rapid and technically easy molecular detection and identification method forL.brunneus.Species-specific primers were designed from the cytochrome c oxidase subunit I region ofL.brunneusand used in development and testing of methods for successfully identifying them from their frass using the loop-mediated isothermal amplification (LAMP) or species-specific nested polymerase chain reaction (PCR) assays. The LAMP assay was faster and more sensitive for detecting the presence of DNA derived fromL.brunneusin their frass than the nested PCR assay. These methodologies will be applicable for the rapid detection and identification of other wood-boring invasive pests in regulatory applications. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. A rapid and cost effective method for soil carbon mineralization under static incubations

    USDA-ARS?s Scientific Manuscript database

    Soil incubations with subsequent determination of carbon dioxide (CO2) are common soil assays used to estimate C mineralization rates and active organic C pools. Two common methods used to detect CO2 in laboratory incubations are gas chromatography (GC) and alkali absorption followed by titration (...

  8. The rapid quantitation of the filamentous blue-green alga plectonema boryanum by the luciferase assay for ATP

    NASA Technical Reports Server (NTRS)

    Bush, V. N.

    1974-01-01

    Plectonema boryanum is a filamentous blue green alga. Blue green algae have a procaryotic cellular organization similar to bacteria, but are usually obligate photoautotrophs, obtaining their carbon and energy from photosynthetic mechanism similar to higher plants. This research deals with a comparison of three methods of quantitating filamentous populations: microscopic cell counts, the luciferase assay for ATP and optical density measurements.

  9. Visual Detection of West Nile Virus Using Reverse Transcription Loop-Mediated Isothermal Amplification Combined with a Vertical Flow Visualization Strip.

    PubMed

    Cao, Zengguo; Wang, Hualei; Wang, Lina; Li, Ling; Jin, Hongli; Xu, Changping; Feng, Na; Wang, Jianzhong; Li, Qian; Zhao, Yongkun; Wang, Tiecheng; Gao, Yuwei; Lu, Yiyu; Yang, Songtao; Xia, Xianzhu

    2016-01-01

    West Nile virus (WNV) causes a severe zoonosis, which can lead to a large number of casualties and considerable economic losses. A rapid and accurate identification method for WNV for use in field laboratories is urgently needed. Here, a method utilizing reverse transcription loop-mediated isothermal amplification combined with a vertical flow visualization strip (RT-LAMP-VF) was developed to detect the envelope (E) gene of WNV. The RT-LAMP-VF assay could detect 10(2) copies/μl of an WNV RNA standard using a 40 min amplification reaction followed by a 2 min incubation of the amplification product on the visualization strip, and no cross-reaction with other closely related members of the Flavivirus genus was observed. The assay was further evaluated using cells and mouse brain tissues infected with a recombinant rabies virus expressing the E protein of WNV. The assay produced sensitivities of 10(1.5) TCID50/ml and 10(1.33) TCID50/ml for detection of the recombinant virus in the cells and brain tissues, respectively. Overall, the RT-LAMP-VF assay developed in this study is rapid, simple and effective, and it is therefore suitable for clinical application in the field.

  10. Detection of Puccinia kuehnii Causing Sugarcane Orange Rust with a Loop-Mediated Isothermal Amplification-Based Assay.

    PubMed

    Chandra, Amaresh; Keizerweerd, Amber T; Grisham, Michael P

    2016-03-01

    Puccinia kuehnii is a fungal pathogen that causes orange rust in sugarcane, which is now prevalent in many countries. At the early stage of disease, it is almost indistinguishable from brown rust, which is caused by Puccinia melanocephala. Although several PCR assays are available to detect these diseases, the loop-mediated isothermal amplification (LAMP)-based assay has been reported to be more economical and easier to perform. Under isothermal conditions, DNA is amplified with high specificity and rapidity. Moreover, visual judgment of color change without further post-amplification processing makes the method convenient. The present study was undertaken to detect P. kuehnii genomic DNA using four primers corresponding to a unique DNA sequence of P. kuehnii. The LAMP assay was found to be optimal when 8 mM MgSO4 was used and the reaction was incubated at 63 °C for 90 min. Positive samples showed a color change from orange to green upon SYBR Green I dye addition. Specificity of the LAMP test was checked with DNA of P. melanocephala, which showed no reaction. Sensitivity of the LAMP method was observed to be the same as real-time PCR at 0.1 ng, thus providing a rapid and more affordable option for early disease detection.

  11. Dual-Quantum-Dots-Labeled Lateral Flow Strip Rapidly Quantifies Procalcitonin and C-reactive Protein

    NASA Astrophysics Data System (ADS)

    Qi, XiaoPing; Huang, YunYe; Lin, ZhongShi; Xu, Liang; Yu, Hao

    2016-03-01

    In the article, a dual-quantum-dots-labeled (dual-QDs-labeled) lateral flow strip (LFS) method was developed for the simultaneous and rapid quantitative detection of procalcitonin (PCT) and C-reactive protein (CRP) in the blood. Two QD-antibody conjugates with different fluorescence emission spectra were produced and sprayed on the LFS to capture PCT and CRP in the blood. Furthermore, a double antibody sandwich method for PCT and, meanwhile, a competitive inhibition method for CRP were employed in the LFS. For PCT and CRP in serum assayed by the dual-QDs-labeled LFS, their detection sensitivities reached 0.1 and 1 ng/mL, respectively, and their linear quantitative detection ranges were from 0.3 to 200 ng/mL and from 50 to 250 μg/mL, respectively. There was little evidence that the PCT and CRP assays would be interfered with each other. The correlations for testing CRP and PCT in clinical samples were 99.75 and 97.02 %, respectively, between the dual-QDs-labeled LFS we developed and commercial methods. The rapid quantification of PCT and CRP on dual-QDs-labeled LFS is of great clinical value to distinguish inflammation, bacterial infection, or viral infection and to provide guidance for the use of antibiotics or other medicines.

  12. Rapid and visual detection of Mycobacterium tuberculosis complex using recombinase polymerase amplification combined with lateral flow strips.

    PubMed

    Ma, Qinglin; Liu, Houming; Ye, Feidi; Xiang, Guangxin; Shan, Wanshui; Xing, Wanli

    2017-12-01

    To definitively diagnose active pulmonary Tuberculosis (TB), Mycobacterium tuberculosis complex (MTBC) bacilli must be identified within clinical specimens from patients. In this study, we introduced a rapid and visual detection method of MTBC using recombinase polymerase amplification (RPA) combined with lateral flow (LF) strips. The LF-RPA assay, read results with naked eyes, could detect as few as 5 genome copies of M. tuberculosis H37Rv (ATCC 27294) per reaction and had no cross-reactions with other control bacteria even using excessive amount of template DNA. The system could work well at a broad range of temperature 25-45 °C and reach detectable level even within 5 min. When testing a total of 137 clinical specimens, the sensitivity and specificity of the LF-RPA assay were 100% (95% CI: 95.94%-100%) and 97.92% (95% CI: 88.93%-99.95%), respectively, compared to culture identification method. Therefore, the LF-RPA system we have demonstrated is a rapid, simple, robust method for MTBC detection which, subject to the availability of a suitable sample extraction method, has the potentiality to diagnose TB at the point-of-care testing. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation.

    PubMed

    Dittmer, W U; de Kievit, P; Prins, M W J; Vissers, J L M; Mersch, M E C; Martens, M F W C

    2008-09-30

    A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions as well as the bound/free separation are entirely controlled by magnetic forces induced by electromagnets above and below the sensor chip. During the assay, particles conjugated with tracer antibodies are actuated through the sample for target capture, and rapidly brought to the sensor surface where they bind to immobilized capture antibodies. Weakly or unbound labels are removed with a magnetic force oriented away from the GMR sensor surface. For the measurement of parathyroid hormone (PTH), a detection limit in the 10 pM range is obtained with a total assay time of 15 min when 300 nm particles are used. The same sensitivity can be achieved in 5 min when 500 nm particles are used. If 500 nm particles are employed in a 15-minute assay, then 0.8 pM of PTH is detectable. The low sample volume, high analytical performance and high speed of the test coupled with the compact GMR biosensor make the system especially suitable for sensitive testing outside of laboratory environments.

  14. Rapid identification of Enterobacter hormaechei and Enterobacter cloacae genetic cluster III.

    PubMed

    Ohad, S; Block, C; Kravitz, V; Farber, A; Pilo, S; Breuer, R; Rorman, E

    2014-05-01

    Enterobacter cloacae complex bacteria are of both clinical and environmental importance. Phenotypic methods are unable to distinguish between some of the species in this complex, which often renders their identification incomplete. The goal of this study was to develop molecular assays to identify Enterobacter hormaechei and Ent. cloacae genetic cluster III which are relatively frequently encountered in clinical material. The molecular assays developed in this study are qPCR technology based and served to identify both Ent. hormaechei and Ent. cloacae genetic cluster III. qPCR results were compared to hsp60 sequence analysis. Most clinical isolates were assigned to Ent. hormaechei subsp. steigerwaltii and Ent. cloacae genetic cluster III. The latter was proportionately more frequently isolated from bloodstream infections than from other material (P < 0·05). The qPCR assays detecting Ent. hormaechei and Ent. cloacae genetic cluster III demonstrated high sensitivity and specificity. The presented qPCR assays allow accurate and rapid identification of clinical isolates of the Ent. cloacae complex. The improved identifications obtained can specifically assist analysis of Ent. hormaechei and Ent. cloacae genetic cluster III in nosocomial outbreaks and can promote rapid environmental monitoring. An association was observed between Ent. cloacae cluster III and systemic infection that deserves further attention. © 2014 The Society for Applied Microbiology.

  15. Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water.

    PubMed

    Yu, Hye-Weon; Jang, Am; Kim, Lan Hee; Kim, Sung-Jo; Kim, In S

    2011-09-15

    Due to the increased occurrence of cyanobacterial blooms and their toxins in drinking water sources, effective management based on a sensitive and rapid analytical method is in high demand for security of safe water sources and environmental human health. Here, a competitive fluorescence immunoassay of microcystin-LR (MCYST-LR) is developed in an attempt to improve the sensitivity, analysis time, and ease-of-manipulation of analysis. To serve this aim, a bead-based suspension assay was introduced based on two major sensing elements: an antibody-conjugated quantum dot (QD) detection probe and an antigen-immobilized magnetic bead (MB) competitor. The assay was composed of three steps: the competitive immunological reaction of QD detection probes against analytes and MB competitors, magnetic separation and washing, and the optical signal generation of QDs. The fluorescence intensity was found to be inversely proportional to the MCYST-LR concentration. Under optimized conditions, the proposed assay performed well for the identification and quantitative analysis of MCYST-LR (within 30 min in the range of 0.42-25 μg/L, with a limit of detection of 0.03 μg/L). It is thus expected that this enhanced assay can contribute both to the sensitive and rapid diagnosis of cyanotoxin risk in drinking water and effective management procedures.

  16. Detection of bacterial pathogens in Mongolia meningitis surveillance with a new real-time PCR assay to detect Haemophilus influenzae.

    PubMed

    Wang, Xin; Mair, Raydel; Hatcher, Cynthia; Theodore, M Jordan; Edmond, Karen; Wu, Henry M; Harcourt, Brian H; Carvalho, Maria da Gloria S; Pimenta, Fabiana; Nymadawa, Pagbajab; Altantsetseg, Dorjpurev; Kirsch, Mariah; Satola, Sarah W; Cohn, Amanda; Messonnier, Nancy E; Mayer, Leonard W

    2011-04-01

    Since the implementation of Haemophilus influenzae (Hi) serotype b vaccine, other serotypes and non-typeable strains have taken on greater importance as a cause of Hi diseases. A rapid and accurate method is needed to detect all Hi regardless of the encapsulation status. We developed 2 real-time PCR (rt-PCR) assays to detect specific regions of the protein D gene (hpd). Both hpd assays are very specific and sensitive for detection of Hi. Of the 63 non-Hi isolates representing 21 bacterial species, none was detected by the hpd #1 assay, and only one of 2 H. aphrophilus isolates was detected by the hpd #3 assay. The hpd #1 and #3 assays detected 97% (229/237) and 99% (234/237) of Hi isolates, respectively, and were superior for detection of both typeable and non-typeable Hi isolates, as compared to previously developed rt-PCR targeting ompP2 or bexA. The diagnostic sensitivity and specificity of these rt-PCR assays were assessed on cerebrospinal fluid specimens collected as part of meningitis surveillance in Ulaanbaatar, Mongolia. The etiology (Neisseria meningitidis, Hi, and Streptococcus pneumoniae) of 111 suspected meningitis cases was determined by conventional methods (culture and latex agglutination), previously developed rt-PCR assays, and the new hpd assays. The rt-PCR assays were more sensitive for detection of meningitis pathogens than other classical methods and improved detection from 50% (56/111) to 75% (83/111). The hpd #3 assay identified a non-b Hi that was missed by the bexA assay and other methods. A sensitive rt-PCR assay to detect both typeable and non-typeable Hi is a useful tool for improving Hi disease surveillance especially after Hib vaccine introduction. Published by Elsevier GmbH.

  17. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    PubMed

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or <250 cells/mm or an AIDS-defining illness (delayed ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  18. Development of a rapid assay to detect the dinoflagellate Amyloodinium ocellatum using loop-mediated isothermal amplification (LAMP).

    PubMed

    Picón-Camacho, Sara M; Thompson, William P; Blaylock, Reginald B; Lotz, Jeffrey M

    2013-09-23

    Amyloodinium ocellatum is a highly pathogenic dinoflagellate parasite with global distribution that causes high mortalities in the culture of tropical and sub-tropical marine and estuarine fishes. Diagnosis typically occurs through gross examination following the onset of morbidity, at which point treatment is of limited benefit. In the present study, a new molecular diagnostic tool for the rapid detection of A. ocellatum (AO) was developed using the loop-mediated isothermal amplification method (LAMP). The AO-LAMP assay designed is highly specific using a set of four primers - two outer and two inner primers targeting six different regions on the 5' end of the Small Subunit rDNA region (SSU rDNA) of A. ocellatum. The AO-LAMP assay, optimized for 25-30 min at 62°C, amplified the DNA from A. ocellatum extracted from both water and gill tissue samples and did not amplify DNA from four closely related dinoflagellate sp ecies. The detection limit of the AO-LAMP assay was 10 fg, exceptionally higher than the conventional PCR (1 pg). In addition, the standardized AO-LAMP assay was capable of detecting single tomonts and trophonts; the assay was not affected by the presence of possible inhibitory substances present in environmental water samples or gill samples. The AO-LAMP assay developed in the present study provides a novel useful tool for the simple, rapid and sensitive detection of A. ocellatum in water and gill tissue samples, which could assist in the early detection and improved control of A. ocellatum infections in aquaculture systems. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Lipopolysaccharide Specific Immunochromatography Based Lateral Flow Assay for Serogroup Specific Diagnosis of Leptospirosis in India

    PubMed Central

    Vanithamani, Shanmugam; Shanmughapriya, Santhanam; Narayanan, Ramasamy; Raja, Veerapandian; Kanagavel, Murugesan; Sivasankari, Karikalacholan; Natarajaseenivasan, Kalimuthusamy

    2015-01-01

    Background Leptospirosis is a re-emerging infectious disease that is under-recognized due to low-sensitivity and cumbersome serological tests. MAT is the gold standard test and it is the only serogroup specific test used till date. Rapid reliable alternative serogroup specific tests are needed for surveillance studies to identify locally circulating serogroups in the study area. Methods/Principal Findings In the present investigation the serological specificity of leptospiral lipopolysaccharides (LPS) was evaluated by enzyme linked immunosorbent assay (ELISA), dot blot assay and rapid immunochromatography based lateral flow assay (ICG-LFA). Sera samples from 120 MAT positive cases, 174 cases with febrile illness other than leptospirosis, and 121 seronegative healthy controls were evaluated for the diagnostic sensitivity and specificity of the developed assays. LPS was extracted from five locally predominant circulating serogroups including: Australis (27.5%), Autumnalis (11.7%), Ballum (25.8%), Grippotyphosa (12.5%), Pomona (10%) and were used as antigens in the diagnostics to detect IgM antibodies in patients’ sera. The sensitivity observed by IgM ELISA and dot blot assay using various leptospiral LPS was >90% for homologous sera. Except for Ballum LPS, no other LPS showed cross-reactivity to heterologous sera. An attempt was made to develop LPS based ICG-LFA for rapid and sensitive serogroup specific diagnostics of leptospirosis. The developed ICG-LFA showed sensitivity in the range between 93 and 100% for homologous sera. The Wilcoxon analysis showed LPS based ICG-LFA did not differ significantly from the gold standard MAT (P>0.05). Conclusion The application of single array of LPS for serogroup specific diagnosis is first of its kind. The developed assay could potentially be evaluated and employed for as MAT alternative. PMID:26340095

  20. Rapid combined assay for Salmonella detection in food samples.

    PubMed

    Gadó, I; Major, P; Király, M; Pláveczky, M G

    2000-01-01

    A rapid method was developed to detect salmonellae in food samples. The method gave a possibility to obtain results after 28 h 30 min. The preenrichment in buffered peptone water lasted for 6 h, the enrichment in Rappaport-Vassiliadis medium was applied for 18 h followed by PCR with INVA1-INVA2 primer pair, adapting Chiu and Ou's method. This procedure was suitable to demonstrate salmonella contamination at min. 10 cfu/25 g sample. Out of 18 samples there was a good agreement between the results of the conventional and rapid methods in case of 17 samples. PCR with SPVC1-SPVC2 primer pair informing about the presence of virulence plasmid was performed in separate tubes, because decreased sensitivity was observed in case of multiplex PCR.

  1. Microscopic-observation drug susceptibility and thin layer agar assays for the detection of drug resistant tuberculosis: a systematic review and meta-analysis.

    PubMed

    Minion, Jessica; Leung, Erika; Menzies, Dick; Pai, Madhukar

    2010-10-01

    Simple, rapid, and affordable tests are needed to detect drug resistance in Mycobacterium tuberculosis. We did a systematic review and meta-analysis to investigate the accuracy of microscopic-observation drug susceptibility (MODS) and thin layer agar (TLA) assays for rapid screening of patients at risk of drug-resistant tuberculosis. In accordance with protocols and methods recommended by the Cochrane Diagnostic Test Accuracy Working Group, we systematically searched PubMed, Embase, and Biosis for reports published between January, 1990, and February, 2009. We included studies investigating detection of drug resistance in M tuberculosis with the MODS or TLA assay, and in which an accepted reference standard was used. Data extracted from the studies were combined by use of bivariate random-effects regression models and hierarchical summary receiver operating characteristic curves to estimate sensitivity and specificity for detection of resistance to specific drugs. We identified 12 studies, of which nine investigated the MODS assay and three investigated the TLA assay. For the MODS assay of rifampicin resistance, pooled estimates were 98·0% (95% CI 94·5-99·3) for sensitivity and 99·4% (95·7-99·9) for specificity. For the MODS assay of isoniazid resistance with a 0·1 μg/mL cutoff, pooled sensitivity was 97·7% (94·4-99·1) and pooled specificity was 95·8% (88·1-98·6), but with a 0·4 μg/mL cutoff, sensitivity decreased to 90·0% (84·5-93·7) and specificity increased to 98·6% (96·9-99·4). All assessments of rifampicin and isoniazid resistance with the TLA assay yielded 100% accuracy. Mean turnaround time was 9·9 days (95% CI 4·1-15·8) for the MODS assay and 11·1 days (10·1-12·0) for the TLA assay. MODS and TLA assays are inexpensive, rapid alternatives to conventional methods for drug susceptibility testing of M tuberculosis. Our data and expert opinion informed WHO's recommendation for use of selected non-commercial drug susceptibility tests, including MODS, as an interim solution until capacity for genotypic or automated liquid culture drug susceptibility testing is developed. Stop TB Department of WHO. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Rapid polymerase chain reaction-based screening assay for bacterial biothreat agents.

    PubMed

    Yang, Samuel; Rothman, Richard E; Hardick, Justin; Kuroki, Marcos; Hardick, Andrew; Doshi, Vishal; Ramachandran, Padmini; Gaydos, Charlotte A

    2008-04-01

    To design and evaluate a rapid polymerase chain reaction (PCR)-based assay for detecting Eubacteria and performing early screening for selected Class A biothreat bacterial pathogens. The authors designed a two-step PCR-based algorithm consisting of an initial broad-based universal detection step, followed by specific pathogen identification targeted for identification of the Class A bacterial biothreat agents. A region in the bacterial 16S rRNA gene containing a highly variable sequence flanked by clusters of conserved sequences was chosen as the target for the PCR assay design. A previously described highly conserved region located within the 16S rRNA amplicon was selected as the universal probe (UniProbe, Integrated DNA Technology, Coralville, IA). Pathogen-specific TaqMan probes were designed for Bacillus anthracis, Yersinia pestis, and Francisella tularensis. Performance of the assay was assessed using genomic DNA extracted from the aforementioned biothreat-related organisms (inactivated or surrogate) and other common bacteria. The UniProbe detected the presence of all tested Eubacteria (31/31) with high analytical sensitivity. The biothreat-specific probes accurately identified organisms down to the closely related species and genus level, but were unable to discriminate between very close surrogates, such as Yersinia philomiragia and Bacillus cereus. A simple, two-step PCR-based assay proved capable of both universal bacterial detection and identification of select Class A bacterial biothreat and biothreat-related pathogens. Although this assay requires confirmatory testing for definitive species identification, the method has great potential for use in ED-based settings for rapid diagnosis in cases of suspected Category A bacterial biothreat agents.

  3. Rapid multiplex PCR and Real-Time TaqMan PCR assays for detection of Salmonella enterica and the highly virulent serovars Choleraesuis and Paratyphi C

    USDA-ARS?s Scientific Manuscript database

    Salmonella enterica is a human pathogen with over 2,500 serovars characterized. S. enterica serovars Choleraesuis (Cs) and Paratyphi C (Pc) are two globally distributed serovars. We have developed a rapid molecular typing method to detect Cs and Pc in food samples by using a comparative genomics ap...

  4. Rapid and Quantitative Detection of Vibrio parahemolyticus by the Mixed-Dye-Based Loop-Mediated Isothermal Amplification Assay on a Self-Priming Compartmentalization Microfluidic Chip.

    PubMed

    Pang, Bo; Ding, Xiong; Wang, Guoping; Zhao, Chao; Xu, Yanan; Fu, Kaiyue; Sun, Jingjing; Song, Xiuling; Wu, Wenshuai; Liu, Yushen; Song, Qi; Hu, Jiumei; Li, Juan; Mu, Ying

    2017-12-27

    Vibrio parahemolyticus (VP) mostly isolated from aquatic products is one of the major causes of bacterial food-poisoning events worldwide, which could be reduced using a promising on-site detection method. Herein, a rapid and quantitative method for VP detection was developed by applying a mixed-dye-loaded loop-mediated isothermal amplification (LAMP) assay on a self-priming compartmentalization (SPC) microfluidic chip, termed on-chip mixed-dye-based LAMP (CMD-LAMP). In comparison to conventional approaches, CMD-LAMP was advantageous on the limit of detection, which reached down to 1 × 10 3 CFU/mL in food-contaminated samples without the pre-enrichment of bacteria. Additionally, as a result of the use of a mixed dye and SPC chip, the quantitative result could be easily acquired, avoiding the requirement of sophisticated instruments and tedious operation. Also, CMD-LAMP was rapid and cost-effective. Conclusively, CMD-LAMP has great potential in realizing the on-site quantitative analysis of VP for food safety.

  5. Development of a nested-PCR assay for the rapid detection of Pilidiella granati in pomegranate fruit

    PubMed Central

    Yang, Xue; Hameed, Uzma; Zhang, Ai-Fang; Zang, Hao-Yu; Gu, Chun-Yan; Chen, Yu; Xu, Yi-Liu

    2017-01-01

    Pilidiella granati, a causal agent of twig blight and crown rot of pomegranate, is an emerging threat that may cause severe risk to the pomegranate industry in the future. Development of a rapid assay for the timely and accurate detection of P. granati will be helpful in the active surveillance and management of the disease caused by this pathogen. In this study, a nested PCR method was established for the detection of P. granati. Comparative analysis of genetic diversity within 5.8S rDNA internal transcribed spacer (ITS) sequences of P. granati and 21 other selected fungal species was performed to design species-specific primers (S1 and S2). This primer pair successfully amplified a 450 bp product exclusively from the genomic DNA of P. granati. The developed method can detect 10 pg genomic DNA of the pathogen in about 6 h. This technique was successfully applied to detect the natural infection of P. granati in the pomegranate fruit. The designed protocol is rapid and precise with a high degree of sensitivity. PMID:28106107

  6. Resolution of common dietary sugars from probe sugars for test of intestinal permeability using capillary column gas chromatography.

    PubMed

    Farhadi, Ashkan; Keshavarzian, Ali; Fields, Jeremy Z; Sheikh, Maliha; Banan, Ali

    2006-05-19

    The most widely accepted method for the evaluation of intestinal barrier integrity is the measurement of the permeation of sugar probes following an oral test dose of sugars. The most-widely used sugar probes are sucrose, lactulose, mannitol and sucralose. Measuring these sugars using a sensitive gas chromatographic (GC) method, we noticed interference on the area of the lactulose and mannitol peaks. We tested different sugars to detect the possible makeup of these interferences and finally detected that the lactose interferes with lactulose peak and fructose interferes with mannitol peak. On further developing of our method, we were able to reasonably separate these peaks using different columns and condition for our assay. Sample preparation was rapid and simple and included adding internal standard sugars, derivitization and silylation. We used two chromatographic methods. In the first method we used Megabore column and had a run time of 34 min. This resulted in partial separation of the peaks. In the second method we used thin capillary column and was able to reasonably separate the lactose and lactulose peaks and the mannitol and fructose peaks with run time of 22 min. The sugar probes including mannitol, sucrose, lactulose, sucralose, fructose and lactose were detected precisely, without interference. The assay was linear between lactulose concentrations of 0.5 and 40 g/L (r(2)=1.000, P<0.0001) and mannitol concentrations of 0.01 and 40 g/L (r(2)=1.000). The sensitivity of this method remained high using new column and assay condition. The minimum detectable concentration calculated for both methods was 0.5 mg/L for lactulose and 1 mg/L for mannitol. This is the first report of interference of commonly used sugars with test of intestinal permeability. These sugars are found in most of fruits and dairy products and could easily interfere with the result of permeability tests. Our new GC assay of urine sugar probes permits the simultaneous quantitation of sucralose, sucrose, mannitol and lactulose, without interference with lactose and fructose. This assay is a rapid, simple, sensitive and reproducible method to accurately measure intestinal permeability.

  7. A rapid method for selecting suitable animal species for studying pathogen interactions with plasma protein ligands in vivo.

    PubMed

    Naudin, Clément; Schumski, Ariane; Salo-Ahen, Outi M H; Herwald, Heiko; Smeds, Emanuel

    2017-05-01

    Species tropism constitutes a serious problem for developing relevant animal models of infection. Human pathogens can express virulence factors that show specific selectivity to human proteins, while their affinity for orthologs from other species can vary significantly. Suitable animal species must be used to analyse whether virulence factors are potential targets for drug development. We developed an assay that rapidly predicts applicable animal species for studying virulence factors binding plasma proteins. We used two well-characterized Staphylococcus aureus proteins, SSL7 and Efb, to develop an ELISA-based inhibition assay using plasma from different animal species. The interaction between SSL7 and human C5 and the binding of Efb to human fibrinogen and human C3 was studied. Affinity experiments and Western blot analyses were used to validate the assay. Human, monkey and cat plasma interfered with binding of SSL7 to human C5. Binding of Efb to human fibrinogen was blocked in human, monkey, gerbil and pig plasma, while human, monkey, gerbil, rabbit, cat and guinea pig plasma inhibited the binding of Efb to human C3. These results emphasize the importance of choosing correct animal models, and thus, our approach is a rapid and cost-effective method that can be used to prevent unnecessary animal experiments. © 2017 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  8. Syphilis screening in the Blood Transfusion Service: a report of four years' experience with the Treponema pallidum haemagglutination assay and the subsequent development of a rapid "spin" method.

    PubMed Central

    Puckett, A; Pratt, G

    1987-01-01

    A comparison of cardiolipin and a modified Treponema pallidum haemagglutination assay (TPHA) method over a four year period confirmed the superior sensitivity and specificity of TPHA. In 86,495 new donor sera 19 (0.02%) confirmed positive results were detected by TPHA, 10 of which did not react by the cardiolipin test. In 150,789 antenatal samples 49 confirmed positive results were found by TPHA, 30 of which did not react by cardiolipin. No cardiolipin positive, TPHA negative samples were confirmed as positive by the absorbed fluorescence treponemal antibody test, and overall 78% of cardiolipin reactions gave false biological positive results. Cardiolipin tests were continued only because of their speed. A further modification ("spin") of the TPHA has now been developed which is rapid, sensitive, and inexpensive, and in testing 21,807 sera, gave results equivalent to those of the previous "settle" method. Serious consideration should be given to dispensing with cardiolipin tests. PMID:3320095

  9. The Comet assay in insects--Status, prospects and benefits for science.

    PubMed

    Augustyniak, Maria; Gladysz, Marcin; Dziewięcka, Marta

    2016-01-01

    The Comet assay has been recently adapted to investigate DNA damage in insects. The first reports of its use in Drosophila melanogaster appeared in 2002. Since then, the interest in the application of the Comet assay to studies of insects has been rapidly increasing. Many authors see substantial potential in the use of the Comet assay in D. melanogaster for medical toxicology studies. This application could allow the testing of drugs and result in an understanding of the mechanisms of action of toxins, which could significantly influence the limited research that has been performed on vertebrates. The possible perspectives and benefits for science are considered in this review. In the last decade, the use of the Comet assay has been described in insects other than D. melanogaster. Specifically, methods to prepare a cell suspension from insect tissues, which is a difficult task, were analyzed and compared in detail. Furthermore, attention was paid to any differences and modifications in the research protocols, such as the buffer composition and electrophoresis conditions. Various scientific fields in addition to toxicological and ecotoxicological research were considered. We expect the Comet assay to be used in environmental risk assessments and to improve our understanding of many important phenomena of insect life, such as metamorphosis, molting, diapause and quiescence. The use of this method to study species that are of key importance to humans, such as pests and beneficial insects, appears to be highly probable and very promising. The use of the Comet assay for DNA stability testing in insects will most likely rapidly increase in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Simultaneous Detection of 13 Key Bacterial Respiratory Pathogens by Combination of Multiplex PCR and Capillary Electrophoresis.

    PubMed

    Jiang, Lu Xi; Ren, Hong Yu; Zhou, Hai Jian; Zhao, Si Hong; Hou, Bo Yan; Yan, Jian Ping; Qin, Tian; Chen, Yu

    2017-08-01

    Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respiratory bacteria detection methods, we developed a combination of multiplex polymerase chain reaction (PCR) and capillary electrophoresis (MPCE) assay to detect thirteen bacterial pathogens responsible for lower respiratory tract infections, including Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catarrhalis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus, Mycoplasma pneumoniae, Legionella spp., Bordetella pertussis, Mycobacterium tuberculosis complex, Corynebacterium diphtheriae, and Streptococcus pyogenes. Three multiplex PCR reactions were built, and the products were analyzed by capillary electrophoresis using the high-throughput DNA analyzer. The specificity of the MPCE assay was examined and the detection limit was evaluated using DNA samples from each bacterial strain and the simulative samples of each strain. This assay was further evaluated using 152 clinical specimens and compared with real-time PCR reactions. For this assay, three nested-multiplex-PCRs were used to detect these clinical specimens. The detection limits of the MPCE assay for the 13 pathogens were very low and ranged from 10-7 to 10-2 ng/μL. Furthermore, analysis of the 152 clinical specimens yielded a specificity ranging from 96.5%-100.0%, and a sensitivity of 100.0% for the 13 pathogens. This study revealed that the MPCE assay is a rapid, reliable, and high-throughput method with high specificity and sensitivity. This assay has great potential in the molecular epidemiological survey of respiratory pathogens. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  11. Comparison of colorimetric assays with quantitative amino acid analysis for protein quantification of Generalized Modules for Membrane Antigens (GMMA).

    PubMed

    Rossi, Omar; Maggiore, Luana; Necchi, Francesca; Koeberling, Oliver; MacLennan, Calman A; Saul, Allan; Gerke, Christiane

    2015-01-01

    Genetically induced outer membrane particles from Gram-negative bacteria, called Generalized Modules for Membrane Antigens (GMMA), are being investigated as vaccines. Rapid methods are required for estimating the protein content for in-process assays during production. Since GMMA are complex biological structures containing lipid and polysaccharide as well as protein, protein determinations are not necessarily straightforward. We compared protein quantification by Bradford, Lowry, and Non-Interfering assays using bovine serum albumin (BSA) as standard with quantitative amino acid (AA) analysis, the most accurate currently available method for protein quantification. The Lowry assay has the lowest inter- and intra-assay variation and gives the best linearity between protein amount and absorbance. In all three assays, the color yield (optical density per mass of protein) of GMMA was markedly different from that of BSA with a ratio of approximately 4 for the Bradford assay, and highly variable between different GMMA; and approximately 0.7 for the Lowry and Non-Interfering assays, highlighting the need for calibrating the standard used in the colorimetric assay against GMMA quantified by AA analysis. In terms of a combination of ease, reproducibility, and proportionality of protein measurement, and comparability between samples, the Lowry assay was superior to Bradford and Non-Interfering assays for GMMA quantification.

  12. The comet assay: assessment of in vitro and in vivo DNA damage.

    PubMed

    Bajpayee, Mahima; Kumar, Ashutosh; Dhawan, Alok

    2013-01-01

    Rapid industrialization and pursuance of a better life have led to an increase in the amount of chemicals in the environment, which are deleterious to human health. Pesticides, automobile exhausts, and new chemical entities all add to air pollution and have an adverse effect on all living organisms including humans. Sensitive test systems are thus required for accurate hazard identification and risk assessment. The Comet assay has been used widely as a simple, rapid, and sensitive tool for assessment of DNA damage in single cells from both in vitro and in vivo sources as well as in humans. Already, the in vivo comet assay has gained importance as the preferred test for assessing DNA damage in animals for some international regulatory guidelines. The advantages of the in vivo comet assay are its ability to detect DNA damage in any tissue, despite having non-proliferating cells, and its sensitivity to detect genotoxicity. The recommendations from the international workshops held for the comet assay have resulted in establishment of guidelines. The in vitro comet assay conducted in cultured cells and cell lines can be used for screening large number of compounds and at very low concentrations. The in vitro assay has also been automated to provide a high-throughput screening method for new chemical entities, as well as environmental samples. This chapter details the in vitro comet assay using the 96-well plate and in vivo comet assay in multiple organs of the mouse.

  13. Digital microfluidic platform for multiplexing enzyme assays: implications for lysosomal storage disease screening in newborns.

    PubMed

    Sista, Ramakrishna S; Eckhardt, Allen E; Wang, Tong; Graham, Carrie; Rouse, Jeremy L; Norton, Scott M; Srinivasan, Vijay; Pollack, Michael G; Tolun, Adviye A; Bali, Deeksha; Millington, David S; Pamula, Vamsee K

    2011-10-01

    Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.

  14. Most Probable Number - Loop Mediated Isothermal Amplification (MPN-LAMP) for Quantifying Waterborne Pathogens in Less Than 25 Minutes

    PubMed Central

    Ahmad, Farhan; Stedtfeld, Robert D.; Waseem, Hassan; Williams, Maggie R.; Cupples, Alison M.; Tiedje, James M.; Hashsham, Syed A.

    2016-01-01

    We are reporting a most probable number approach integrated to loop mediated isothermal technique (MPN-LAMP) focusing on Gram-negative Escherichia coli and Gram-positive Enterococcus faecalis bacterial cells without nucleic acids extraction. LAMP assays for uidA from E. coli and gelE from E. faecalis were successfully performed directly on cells up to single digit concentration using a commercial real time PCR instrument. Threshold time values of LAMP assays of bacterial cells, heat treated bacterial cells (95 °C for 5 min), and their purified genomic DNA templates were similar, implying that amplification could be achieved directly from bacterial cells at 63 °C. Viability of bacterial cells was confirmed by using propidium monoazide in a LAMP assay with E. faecalis. To check its functionality on a microfluidic platform, MPN-LAMP assays targeting < 10 CFU of bacteria were also translated onto polymeric microchips and monitored by a low-cost fluorescence imaging system. The overall system provided signal-to-noise (SNR) ratios up to 800, analytical sensitivity of < 10 CFU, and time to positivity of about 20 min. MPN-LAMP assays were performed for cell concentrations in the range of 105 CFU to < 10 CFU. MPN values from LAMP assays confirmed that the amplifications were from < 10 CFU. The method described here, applicable directly on cells at 63 °C, eliminates the requirement of complex nucleic acids extraction steps, facilitating the development of sensitive, rapid, low-cost, and field-deployable systems. This rapid MPN-LAMP approach has the potential to replace conventional MPN method for waterborne pathogens. PMID:27856278

  15. A new automated turbidimetric immunoassay for the measurement of canine C-reactive protein.

    PubMed

    Piñeiro, Matilde; Pato, Raquel; Soler, Lourdes; Peña, Raquel; García, Natalia; Torrente, Carlos; Saco, Yolanda; Lampreave, Fermín; Bassols, Anna; Canalias, Francesca

    2018-03-01

    In dogs, as in humans, C-reactive protein (CRP) is a major acute phase protein that is rapidly and prominently increased after exposure to inflammatory stimuli. CRP measurements are used in the diagnosis and monitoring of infectious and inflammatory diseases. The study aim was to develop and validate a turbidimetric immunoassay for the quantification of canine CRP (cCRP), using canine-specific reagents and standards. A particle-enhanced turbidimetric immunoassay was developed. The assay was set up in a fully automated analyzer, and studies of imprecision, limits of linearity, limits of detection, prozone effects, and interferences were carried out. The new method was compared with 2 other commercially available automated immunoassays for cCRP: one turbidimetric immunoassay (Gentian CRP) and one point-of-care assay based on magnetic permeability (Life Assays CRP). The within-run and between-day imprecision were <1.7% and 4.2%, respectively. The assay quantified CRP proportionally in an analytic range up to 150 mg/L, with a prozone effect appearing at cCRP concentrations >320 mg/L. No interference from hemoglobin (20 g/L), triglycerides (10 g/L), or bilirubin (150 mg/L) was detected. Good agreement was observed between the results obtained with the new method and the Gentian cCRP turbidimetric immunoassay. The new turbidimetric immunoassay (Turbovet canine CRP, Acuvet Biotech) is a rapid, robust, precise, and accurate method for the quantification of cCRP. The method can be easily set up in automated analyzers, providing a suitable tool for routine clinical use. © 2018 American Society for Veterinary Clinical Pathology.

  16. Integration of cell-free protein coexpression with an enzyme-linked immunosorbent assay enables rapid analysis of protein–protein interactions directly from DNA

    PubMed Central

    Layton, Curtis J; Hellinga, Homme W

    2011-01-01

    Assays that integrate detection of binding with cell-free protein expression directly from DNA can dramatically increase the pace at which protein–protein interactions (PPIs) can be analyzed by mutagenesis. In this study, we present a method that combines in vitro protein production with an enzyme-linked immunosorbent assay (ELISA) to measure PPIs. This method uses readily available commodity instrumentation and generic antibody–affinity tag interactions. It is straightforward and rapid to execute, enabling many interactions to be assessed in parallel. In traditional ELISAs, reporter complexes are assembled stepwise with one layer at a time. In the method presented here, all the members of the reporter complex are present and assembled together. The signal strength is dependent on all the intercomponent interaction affinities and concentrations. Although this assay is straightforward to execute, establishing proper conditions and analysis of the results require a thorough understanding of the processes that determine the signal strength. The formation of the fully assembled reporter sandwich can be modeled as a competition between Langmuir adsorption isotherms for the immobilized components and binding equilibria of the solution components. We have shown that modeling this process provides semiquantitative understanding of the effects of affinity and concentration and can guide strategies for the development of experimental protocols. We tested the method experimentally using the interaction between a synthetic ankyrin repeat protein (Off7) and maltose-binding protein. Measurements obtained for a collection of alanine mutations in the interface between these two proteins demonstrate that a range of affinities can be analyzed. PMID:21674663

  17. Loop-mediated isothermal amplification (LAMP) assay-A rapid detection tool for identifying red fox (Vulpes vulpes) DNA in the carcasses of harbour porpoises (Phocoena phocoena).

    PubMed

    Heers, Teresa; van Neer, Abbo; Becker, André; Grilo, Miguel Luca; Siebert, Ursula; Abdulmawjood, Amir

    2017-01-01

    Carcasses of wild animals are often visited by different scavengers. However, determining which scavenger caused certain types of bite marks is particularly difficult and knowledge thereof is lacking. Therefore, a loop-mediated isothermal amplification (LAMP) assay (target sequence cytochrome b) was developed to detect red fox DNA in carcasses of harbour porpoises. The MSwab™ method for direct testing without prior DNA isolation was validated. As a detection device, the portable real-time fluorometer Genie® II was used, which yields rapid results and can be used in field studies without huge laboratory equipment. In addition to in vitro evaluation and validation, a stranded and scavenged harbour porpoise carcass was successfully examined for red fox DNA residues. The developed LAMP method is a valuable diagnostic tool for confirming presumable red fox bite wounds in harbour porpoises without further DNA isolation steps.

  18. Development of a PCR-based assay for rapid and reliable identification of pathogenic Fusaria.

    PubMed

    Mishra, Prashant K; Fox, Roland T V; Culham, Alastair

    2003-01-28

    Identification of Fusarium species has always been difficult due to confusing phenotypic classification systems. We have developed a fluorescent-based polymerase chain reaction assay that allows for rapid and reliable identification of five toxigenic and pathogenic Fusarium species. The species includes Fusarium avenaceum, F. culmorum, F. equiseti, F. oxysporum and F. sambucinum. The method is based on the PCR amplification of species-specific DNA fragments using fluorescent oligonucleotide primers, which were designed based on sequence divergence within the internal transcribed spacer region of nuclear ribosomal DNA. Besides providing an accurate, reliable, and quick diagnosis of these Fusaria, another advantage with this method is that it reduces the potential for exposure to carcinogenic chemicals as it substitutes the use of fluorescent dyes in place of ethidium bromide. Apart from its multidisciplinary importance and usefulness, it also obviates the need for gel electrophoresis.

  19. Molecular diagnostics for the detection and characterization of microbial pathogens.

    PubMed

    Procop, Gary W

    2007-09-01

    New and advanced methods of molecular diagnostics are changing the way we practice clinical microbiology, which affects the practice of medicine. Signal amplification and real-time nucleic acid amplification technologies offer a sensitive and specific result with a more rapid turnaround time than has ever before been possible. Numerous methods of postamplification analysis afford the simultaneous detection and differentiation of numerous microbial pathogens, their mechanisms of resistance, and the construction of disease-specific assays. The technical feasibility of these assays has already been demonstrated. How these new, often more expensive tests will be incorporated into routine practice and the impact they will have on patient care remain to be determined. One of the most attractive uses for such techniques is to achieve a more rapid characterization of the infectious agent so that a narrower-spectrum antimicrobial agent may be used, which should have an impact on resistance patterns.

  20. A multiplex immunochromatographic test using gold nanoparticles for the rapid and simultaneous detection of four nitrofuran metabolites in fish samples.

    PubMed

    Wang, Quan; Liu, Yingchun; Wang, Mingyan; Chen, Yongjun; Jiang, Wei

    2018-01-01

    There is an urgent need for the rapid and simultaneous detection of multiple analytes present in a sample matrix. Here, a multiplex immunochromatographic test (multi-ICT) was developed that successfully allowed for the rapid and simultaneous detection of four major nitrofuran metabolites, i.e., 3-amino-2-oxazolidinone (AOZ), semicarbazide (SEM), 3-amino-5-methylmorpholino-2-oxazolidinone (AMOZ), and 1-aminohydantoin (AHD), in fish samples. Four different antigens were separately immobilized in four test lines on a nitrocellulose membrane. Goat anti-mouse immunoglobulin (IgG) was used as a control. Sensitive and specific monoclonal antibodies (mAbs) that recognize the corresponding antigens were selected for the assay, and no cross-reactivity between the antibodies in the detection assay was observed. The free analytes in samples or standards were pre-incubated with freeze-dried mAb-gold conjugates to improve the sensitivity of the detection assay. The multi-ICT detection was accomplished in less than 15 min by the naked eye. The cutoff values for the strip test were 0.5 ng/mL for AOZ and 0.75 ng/mL for AHD, SEM, and AMOZ, which were all below the maximum residue levels set by the European Union and China. A high degree of consistency was observed between the multi-ICT method and commercially available enzyme-linked immunosorbent assay (ELISA) kits using spiked, incurred, and "blind" fish samples, indicating the accuracy, reproducibility, and reliability of the novel test strip. This newly developed multi-ICT strip assay is suitable for the rapid and high-throughput screening of four nitrofuran metabolites in fish samples on-site, with no treatment or devices required. Graphical abstract A multiplex immunochromatographic test (multi-ICT) was developed that successfully allowed for the rapid and simultaneous detection of four major nitrofuran metabolites (AOZ, SEM, AMOZ, and AHD) in fish samples.

  1. Statistical Approach To Estimate Vaccinia-Specific Neutralizing Antibody Titers Using a High-Throughput Assay▿

    PubMed Central

    Kennedy, Richard; Pankratz, V. Shane; Swanson, Eric; Watson, David; Golding, Hana; Poland, Gregory A.

    2009-01-01

    Because of the bioterrorism threat posed by agents such as variola virus, considerable time, resources, and effort have been devoted to biodefense preparation. One avenue of this research has been the development of rapid, sensitive, high-throughput assays to validate immune responses to poxviruses. Here we describe the adaptation of a β-galactosidase reporter-based vaccinia virus neutralization assay to large-scale use in a study that included over 1,000 subjects. We also describe the statistical methods involved in analyzing the large quantity of data generated. The assay and its associated methods should prove useful tools in monitoring immune responses to next-generation smallpox vaccines, studying poxvirus immunity, and evaluating therapeutic agents such as vaccinia virus immune globulin. PMID:19535540

  2. Species-specific differentiation of variola, monkeypox, and varicella-zoster viruses by multiplex real-time PCR assay.

    PubMed

    Maksyutov, Rinat A; Gavrilova, Elena V; Shchelkunov, Sergei N

    2016-10-01

    A method of one-stage rapid detection and differentiation of epidemiologically important variola virus (VARV), monkeypox virus (MPXV), and varicella-zoster virus (VZV) utilizing multiplex real-time TaqMan PCR assay was developed. Four hybridization probes with various fluorescent dyes and the corresponding fluorescence quenchers were simultaneously used for the assay. The hybridization probes specific for the VARV sequence contained FAM/BHQ1 as a dye/quencher pair; MPXV-specific, JOE/BHQ1; VZV-specific, TAMRA/BHQ2; and internal control-specific, Cy5/BHQ3. The specificity and sensitivity of the developed method were assessed by analyzing DNA of 32 strains belonging to orthopoxvirus and herpesvirus species. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Solutions to decrease a systematic error related to AAPH addition in the fluorescence-based ORAC assay.

    PubMed

    Mellado-Ortega, Elena; Zabalgogeazcoa, Iñigo; Vázquez de Aldana, Beatriz R; Arellano, Juan B

    2017-02-15

    Oxygen radical absorbance capacity (ORAC) assay in 96-well multi-detection plate readers is a rapid method to determine total antioxidant capacity (TAC) in biological samples. A disadvantage of this method is that the antioxidant inhibition reaction does not start in all of the 96 wells at the same time due to technical limitations when dispensing the free radical-generating azo initiator 2,2'-azobis (2-methyl-propanimidamide) dihydrochloride (AAPH). The time delay between wells yields a systematic error that causes statistically significant differences in TAC determination of antioxidant solutions depending on their plate position. We propose two alternative solutions to avoid this AAPH-dependent error in ORAC assays. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples

    PubMed Central

    Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie

    2012-01-01

    A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222

  5. Single-step colony assay for screening antibody libraries.

    PubMed

    Kato, Mieko; Hanyu, Yoshiro

    2017-08-10

    We describe a method, single-step colony assay, for simple and rapid screening of single-chain Fv fragment (scFv) libraries. Colonies of Escherichia coli expressing the scFv library are formed on a hydrophilic filter that is positioned in contact with a membrane coated with an antigen. scFv expression is triggered upon treatment of colonies with an induction reagent, following which scFvs are secreted from the cells and diffused to the antigen-coated membrane. scFvs that exhibit binding affinity for the antigen are captured by the membrane-immobilized antigen. Lastly, detection of scFv binding of the antigen on the membrane allows identification of the clones on the filter that express antigen-specific scFvs. We tested this methodology by using an anti-rabbit IgG scFv, scFv(A10B), and a rat immune scFv library. Experiments conducted using scFv(A10B) revealed that this method improves scFv expression during the colony assay. By using our method to screen an immune library of 3×10 3 scFv clones, we established several clones exhibiting affinity for the antigen. Moreover, we tested 7 other antigens, including peptides, and successfully identified positive clones. We believe that this simple procedure and controlled scFv expression of the single-step colony assay could make the antibody screening both rapid and reliable and lead to successful isolation of positive clones from antibody libraries. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Single-Step qPCR and dPCR Detection of Diverse CRISPR-Cas9 Gene Editing Events In Vivo.

    PubMed

    Falabella, Micol; Sun, Linqing; Barr, Justin; Pena, Andressa Z; Kershaw, Erin E; Gingras, Sebastien; Goncharova, Elena A; Kaufman, Brett A

    2017-10-05

    Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)-CRISPR-associated protein 9 (Cas9)-based technology is currently the most flexible means to create targeted mutations by recombination or indel mutations by nonhomologous end joining. During mouse transgenesis, recombinant and indel alleles are often pursued simultaneously. Multiple alleles can be formed in each animal to create significant genetic complexity that complicates the CRISPR-Cas9 approach and analysis. Currently, there are no rapid methods to measure the extent of on-site editing with broad mutation sensitivity. In this study, we demonstrate the allelic diversity arising from targeted CRISPR editing in founder mice. Using this DNA sample collection, we validated specific quantitative and digital PCR methods (qPCR and dPCR, respectively) for measuring the frequency of on-target editing in founder mice. We found that locked nucleic acid (LNA) probes combined with an internal reference probe (Drop-Off Assay) provide accurate measurements of editing rates. The Drop-Off LNA Assay also detected on-target CRISPR-Cas9 gene editing in blastocysts with a sensitivity comparable to PCR-clone sequencing. Lastly, we demonstrate that the allele-specific LNA probes used in qPCR competitor assays can accurately detect recombinant mutations in founder mice. In summary, we show that LNA-based qPCR and dPCR assays provide a rapid method for quantifying the extent of on-target genome editing in vivo , testing RNA guides, and detecting recombinant mutations. Copyright © 2017 Falabella et al.

  7. A rapid and sensitive fluorometric method for the quantitative analysis of snake venom metalloproteases and their inhibitors.

    PubMed

    Biardi, J E; Nguyen, K T; Lander, S; Whitley, M; Nambiar, K P

    2011-02-01

    Metalloproteases are responsible for the hemorrhagic effects of many snake venoms and contribute to other pathways that lead to local tissue damage. Methods that quantify snake venom metalloproteases (SVMP) are therefore valuable tools in research on the clinical, physiological, and biochemical effects of envenomation. Comparative analysis of individual, population, and species differences requires screening of large numbers of samples and treatments, and therefore require a method of quantifying SVMP activity that is simple, rapid, and sensitive. This paper demonstrates the properties of a new fluorometric assay of SVMP activity that can provide a measure of metalloprotease activity in 1 h. The assay is reliable, with variation among replicates sufficiently small to reliably detect differences in between species (F(19,60) = 2924, p < 0.001), even for those venoms with low overall activity. It is also sensitive enough to detect differences among venoms using <2 ng of whole venom protein. We provide an example use of this assay to detect the presence of natural SVMP inhibitors in minute samples of blood plasma from rock squirrels (S. variegatus), a natural prey species for North American rattlesnakes. We propose this assay is a useful addition to the set of tools used to characterize venoms, as well as high-throughput screening of natural or synthetic inhibitors, or other novel therapeutic agents against SVMP effects. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Differentiation of five enterohepatic Helicobacter species by nested PCR with high-resolution melting curve analysis.

    PubMed

    Wu, Miaoli; Rao, Dan; Zhu, Yujun; Wang, Jing; Yuan, Wen; Zhang, Yu; Huang, Ren; Guo, Pengju

    2017-04-01

    Enterohepatic Helicobacter species (EHS) are widespread in rodent species around the world. Several studies have demonstrated that infection with EHS can interfere with the outcomes of animal experiments in cancer research and significantly influence the study results. Therefore, it is essential to establish a rapid detection and identification of EHS for biomedical research using laboratory rodents. Our study aimed to develop a rapid and sensitive method to detect and distinguish five enterohepatic Helicobacter species. Nested PCR followed by high-resolution melting curve analysis (HRM) was developed for identification of H. bilis, H. rodentium, H. muridarum, H. typhlonius, as well as H. hepaticus. To validate the accuracy of nested PCR-HRM analysis, quantitative real-time PCR methods for five different enterohepatic Helicobacter species were developed. A total of 50 cecal samples were tested using both nested PCR-HRM analysis and qPCR method. The nested PCR-HRM method could distinguish five enterohepatic Helicobacter species by different melting temperatures. The melting curve were characterized by peaks of 78.7 ± 0.12°C for H. rodentium, 80.51 ± 0.09°C for H. bilis, 81.6 ± 0.1°C for H. typhlonius, 82.11 ± 0.18°C for H. muridarum, and 82.95 ± 0.09°C for H. hepaticus. The nested PCR-HRM assay is a simple, rapid, and cost-effective assay. This assay could be a useful tool for molecular epidemiology study of enterohepatic Helicobacter infection and an attractive alternative for genotyping of enterohepatic Helicobacter species. © 2016 John Wiley & Sons Ltd.

  9. Rapid and sensitive detection of Zika virus by reverse transcription loop-mediated isothermal amplification.

    PubMed

    Wang, Xuan; Yin, Fenggui; Bi, Yuhai; Cheng, Gong; Li, Jing; Hou, Lidan; Li, Yunlong; Yang, Baozhi; Liu, Wenjun; Yang, Limin

    2016-12-01

    Zika virus (ZIKV) is an arbovirus that recently emerged and has expanded worldwide, causing a global threat and raising international concerns. Current molecular diagnostics, e.g., real-time PCR and reverse transcription PCR (RT-PCR), are time consuming, expensive, and can only be deployed in a laboratory instead of for field diagnostics. This study aimed to develop a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) platform showing sensitivity, specificity, and more convenience than previous methods, being easily distributed and implemented. Specific primers were designed and screened to target the entire ZIKV genome. The analytical sensitivity and specificity of the assay were evaluated and compared with traditional PCR and quantitative real-time PCR. Three different simulated clinical sample quick preparation protocols were evaluated to establish a rapid and straightforward treatment procedure for clinical specimens in open field detection. The RT-LAMP assay for detection of ZIKV demonstrated superior specificity and sensitivity compared to traditional PCR at the optimum reaction temperature. For the ZIKV RNA standard, the limit of detection was 20 copies/test. For the simulated ZIKV clinical samples, the limit of detection was 0.02 pfu/test, which was one order of magnitude higher than RT-PCR and similar to real-time PCR. The detection limit of simulated ZIKV specimens prepared using a protease quick processing method was consistent with that of samples prepared using commercial nucleic acid extraction kits, indicating that our ZIKV detection method could be used in point-of-care testing. The RT-LAMP assay had excellent sensitivity and specificity for detecting ZIKV and can be deployed together with a rapid specimen processing method, offering the possibility for ZIKV diagnosis outside of the laboratory. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Development of a rapid HRM qPCR for the diagnosis of the four most prevalent Plasmodium lineages in New Zealand.

    PubMed

    Schoener, E R; Hunter, S; Howe, L

    2017-07-01

    Although wildlife rehabilitation and translocations are important tools in wildlife conservation in New Zealand, disease screening of birds has not been standardized. Additionally, the results of the screening programmes are often difficult to interpret due to missing disease data in resident or translocating avian populations. Molecular methods have become the most widespread method for diagnosing avian malaria (Plasmodium spp.) infections. However, these methods can be time-consuming, expensive and are less specific in diagnosing mixed infections. Thus, this study developed a new real-time PCR (qPCR) method that was able to detect and specifically identify infections of the three most common lineages of avian malaria in New Zealand (Plasmodium (Novyella) sp. SYAT05, Plasmodium elongatum GRW6 and Plasmodium spp. LINN1) as well as a less common, pathogenic Plasmodium relictum GRW4 lineage. The assay was also able to discern combinations of these parasites in the same sample and had a detection limit of five parasites per microlitre. Due to concerns relating to the presence of the potentially highly pathogenic P. relictum GRW4 lineage in avian populations, an additional confirmatory high resolution (HRM) qPCR was developed to distinguish between commonly identified P. elongatum GRW6 from P. relictum GRW4. The new qPCR assays were tested using tissue samples containing Plasmodium schizonts from three naturally infected dead birds resulting in the identified infection of P. elongatum GRW6. Thus, these rapid qPCR assays have shown to be cost-effective and rapid screening tools for the detection of Plasmodium infection in New Zealand native birds.

  11. Loop-Mediated Isothermal Amplification for Detection of Endogenous Sad1 Gene in Cotton: An Internal Control for Rapid Onsite GMO Testing.

    PubMed

    Singh, Monika; Bhoge, Rajesh K; Randhawa, Gurinderjit

    2018-04-20

    Background : Confirming the integrity of seed samples in powdered form is important priorto conducting a genetically modified organism (GMO) test. Rapid onsite methods may provide a technological solution to check for genetically modified (GM) events at ports of entry. In India, Bt cotton is the commercialized GM crop with four approved GM events; however, 59 GM events have been approved globally. GMO screening is required to test for authorized GM events. The identity and amplifiability of test samples could be ensured first by employing endogenous genes as an internal control. Objective : A rapid onsite detection method was developed for an endogenous reference gene, stearoyl acyl carrier protein desaturase ( Sad1 ) of cotton, employing visual and real-time loop-mediated isothermal amplification (LAMP). Methods : The assays were performed at a constant temperature of 63°C for 30 min for visual LAMP and 62ºC for 40 min for real-time LAMP. Positive amplification was visualized as a change in color from orange to green on addition of SYBR ® Green or detected as real-time amplification curves. Results : Specificity of LAMP assays was confirmed using a set of 10 samples. LOD for visual LAMP was up to 0.1%, detecting 40 target copies, and for real-time LAMP up to 0.05%, detecting 20 target copies. Conclusions : The developed methods could be utilized to confirm the integrity of seed powder prior to conducting a GMO test for specific GM events of cotton. Highlights : LAMP assays for the endogenous Sad1 gene of cotton have been developed to be used as an internal control for onsite GMO testing in cotton.

  12. Rapid, simple and direct detection of Meloidogyne hapla from infected root galls using loop-mediated isothermal amplification combined with FTA technology

    PubMed Central

    Peng, Huan; Long, Haibo; Huang, Wenkun; Liu, Jing; Cui, Jiangkuan; Kong, Lingan; Hu, Xianqi; Gu, Jianfeng; Peng, Deliang

    2017-01-01

    The northern root-knot nematode (Meloidogyne hapla) is a damaging nematode that has caused serious economic losses worldwide. In the present study, a sensitive, simple and rapid method was developed for detection of M. hapla in infested plant roots by combining a Flinders Technology Associates (FTA) card with loop-mediated isothermal amplification (LAMP). The specific primers of LAMP were designed based on the distinction of internal transcribed spacer (ITS) sequences between M. hapla and other Meloidogyne spp. The LAMP assay can detect nematode genomic DNA at concentrations low to 1/200 000, which is 100 times more sensitive than conventional PCR. The LAMP was able to highly specifically distinguish M. hapla from other closely related nematode species. Furthermore, the advantages of the FTA-LAMP assay to detect M. hapla were demonstrated by assaying infected root galls that were artificially inoculated. In addition, M. hapla was successfully detected from six of forty-two field samples using FTA-LAMP technology. This study was the first to provide a simple diagnostic assay for M. hapla using the LAMP assay combined with FTA technology. In conclusion, the new FTA-LAMP assay has the potential for diagnosing infestation in the field and managing the pathogen M. hapla. PMID:28368036

  13. Rapid, simple and direct detection of Meloidogyne hapla from infected root galls using loop-mediated isothermal amplification combined with FTA technology.

    PubMed

    Peng, Huan; Long, Haibo; Huang, Wenkun; Liu, Jing; Cui, Jiangkuan; Kong, Lingan; Hu, Xianqi; Gu, Jianfeng; Peng, Deliang

    2017-04-03

    The northern root-knot nematode (Meloidogyne hapla) is a damaging nematode that has caused serious economic losses worldwide. In the present study, a sensitive, simple and rapid method was developed for detection of M. hapla in infested plant roots by combining a Flinders Technology Associates (FTA) card with loop-mediated isothermal amplification (LAMP). The specific primers of LAMP were designed based on the distinction of internal transcribed spacer (ITS) sequences between M. hapla and other Meloidogyne spp. The LAMP assay can detect nematode genomic DNA at concentrations low to 1/200 000, which is 100 times more sensitive than conventional PCR. The LAMP was able to highly specifically distinguish M. hapla from other closely related nematode species. Furthermore, the advantages of the FTA-LAMP assay to detect M. hapla were demonstrated by assaying infected root galls that were artificially inoculated. In addition, M. hapla was successfully detected from six of forty-two field samples using FTA-LAMP technology. This study was the first to provide a simple diagnostic assay for M. hapla using the LAMP assay combined with FTA technology. In conclusion, the new FTA-LAMP assay has the potential for diagnosing infestation in the field and managing the pathogen M. hapla.

  14. Identification and genotyping of molluscum contagiosum virus from genital swab samples by real-time PCR and Pyrosequencing.

    PubMed

    Trama, Jason P; Adelson, Martin E; Mordechai, Eli

    2007-12-01

    Laboratory diagnosis of molluscum contagiosum virus (MCV) is important as lesions can be confused with those caused by Cryptococcus neoformans, herpes simplex virus, human papillomavirus, and varicella-zoster virus. To develop a rapid method for identifying patients infected with MCV via swab sampling. Two dual-labeled probe real-time PCR assays, one homologous to the p43K gene and one to the MC080R gene, were designed. The p43K PCR was designed to be used in conjunction with Pyrosequencing for confirmation of PCR products and discrimination between MCV1 and MCV2. Both PCR assays were optimized with respect to reaction components, thermocycling parameters, and primer and probe concentrations. The specificities of both PCR assays were confirmed by non-amplification of 38 known human pathogens. Sensitivity assays demonstrated detection of as few as 10 copies per reaction. Testing 703 swabs, concordance between the two real-time PCR assays was 99.9%. Under the developed conditions, Pyrosequencing of the p43K PCR product was capable of providing enough nucleotide sequence to definitively differentiate MCV1 and MCV2. These real-time PCR assays can be used for the rapid, sensitive, and specific detection of MCV and, when combined with Pyrosequencing, can further discriminate between MCV1 and MCV2.

  15. Immunochromatographic strip assay for the rapid and sensitive detection of Salmonella Typhimurium in artificially contaminated tomato samples.

    PubMed

    Shukla, Shruti; Leem, Hyerim; Lee, Jong-Suk; Kim, Myunghee

    2014-06-01

    This study was designed to confirm the applicability of a liposome-based immunochromatographic assay for the rapid detection of Salmonella enterica subsp. enterica serovar Typhimurium (Salmonella Typhimurium) in artificially contaminated tomato samples. To determine the detection limit and pre-enrichment incubation time (10, 12, and 18 h pre-enrichment in 1% buffered peptone water), the tests were performed with different cell numbers of Salmonella Typhimurium (3 × 10(0), 3 × 10(1), 3 × 10(2), and 3 × 10(3) CFU·mL(-1)) inoculated into 25 g of crushed tomato samples. The assay was able to detect as few as 30 Salmonella Typhimurium cells per 25 g of tomato samples (1.2 cells·g(-1)) after 12 h pre-enrichment incubation. Moreover, when the developed assay was compared with traditional morphological and biochemical culture-based methods as well as colloidal gold nanoparticle-based commercial test strips, the developed assay yielded positive results for the detection of Salmonella Typhimurium within a shorter period time. These findings confirm that the developed assay may have practical application for the sensitive detection of Salmonella Typhimurium in various food samples, including raw vegetables, with a relatively low detection limit and shorter analysis time.

  16. Development of a loop-mediated isothermal amplification assay for the detection of Streptococcus agalactiae in bovine milk.

    PubMed

    Bosward, Katrina L; House, John K; Deveridge, Amber; Mathews, Karen; Sheehy, Paul A

    2016-03-01

    Streptococcus agalactiae is a well-characterized bovine mastitis pathogen that is known to be highly contagious and capable of spreading rapidly in affected dairy herds. Loop-mediated isothermal amplification (LAMP) is a novel molecular diagnostic method that has the capability to provide rapid, cost-effective screening for pathogens to support on-farm disease control and eradication programs. In the current study, a LAMP test was developed to detect S. agalactiae in milk. The assay was validated on a bank of existing clinical mastitis milk samples that had previously been identified as S. agalactiae positive via traditional microbiological culture techniques and PCR. The LAMP assay was conducted on bacterial colonies and DNA extracted from milk in tube- and plate-based formats using multiple detection platforms. The 1-h assay conducted at 64 °C exhibited repeatability (coefficient of variation) of 2.07% (tube) and 8.3% (plate), sensitivity to ~20 pg of extracted DNA/reaction, and specificity against a panel of known bacterial mastitis pathogens. Of the 109 known S. agalactiae isolates assessed by LAMP directly from bacterial cells in culture, 108 were identified as positive, in accordance with PCR analysis. The LAMP analysis from the corresponding milk samples indicated that 104 of these milks exhibited a positive amplification curve. Although exhibiting some limitations, this assay provides an opportunity for rapid screening of milk samples to facilitate on-farm management of this pathogen. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Target-Specific Assay for Rapid and Quantitative Detection of Mycobacterium chimaera DNA

    PubMed Central

    Zozaya-Valdés, Enrique; Porter, Jessica L.; Coventry, John; Fyfe, Janet A. M.; Carter, Glen P.; Gonçalves da Silva, Anders; Schultz, Mark B.; Seemann, Torsten; Johnson, Paul D. R.; Stewardson, Andrew J.; Bastian, Ivan; Roberts, Sally A.; Howden, Benjamin P.; Williamson, Deborah A.

    2017-01-01

    ABSTRACT Mycobacterium chimaera is an opportunistic environmental mycobacterium belonging to the Mycobacterium avium-M. intracellulare complex. Although most commonly associated with pulmonary disease, there has been growing awareness of invasive M. chimaera infections following cardiac surgery. Investigations suggest worldwide spread of a specific M. chimaera clone, associated with contaminated hospital heater-cooler units used during the surgery. Given the global dissemination of this clone, its potential to cause invasive disease, and the laboriousness of current culture-based diagnostic methods, there is a pressing need to develop rapid and accurate diagnostic assays specific for M. chimaera. Here, we assessed 354 mycobacterial genome sequences and confirmed that M. chimaera is a phylogenetically coherent group. In silico comparisons indicated six DNA regions present only in M. chimaera. We targeted one of these regions and developed a TaqMan quantitative PCR (qPCR) assay for M. chimaera with a detection limit of 100 CFU/ml in whole blood spiked with bacteria. In vitro screening against DNA extracted from 40 other mycobacterial species and 22 bacterial species from 21 diverse genera confirmed the in silico-predicted specificity for M. chimaera. Screening 33 water samples from heater-cooler units with this assay highlighted the increased sensitivity of PCR compared to culture, with 15 of 23 culture-negative samples positive by M. chimaera qPCR. We have thus developed a robust molecular assay that can be readily and rapidly deployed to screen clinical and environmental specimens for M. chimaera. PMID:28381604

  18. Target-Specific Assay for Rapid and Quantitative Detection of Mycobacterium chimaera DNA.

    PubMed

    Zozaya-Valdés, Enrique; Porter, Jessica L; Coventry, John; Fyfe, Janet A M; Carter, Glen P; Gonçalves da Silva, Anders; Schultz, Mark B; Seemann, Torsten; Johnson, Paul D R; Stewardson, Andrew J; Bastian, Ivan; Roberts, Sally A; Howden, Benjamin P; Williamson, Deborah A; Stinear, Timothy P

    2017-06-01

    Mycobacterium chimaera is an opportunistic environmental mycobacterium belonging to the Mycobacterium avium - M. intracellulare complex. Although most commonly associated with pulmonary disease, there has been growing awareness of invasive M. chimaera infections following cardiac surgery. Investigations suggest worldwide spread of a specific M. chimaera clone, associated with contaminated hospital heater-cooler units used during the surgery. Given the global dissemination of this clone, its potential to cause invasive disease, and the laboriousness of current culture-based diagnostic methods, there is a pressing need to develop rapid and accurate diagnostic assays specific for M. chimaera Here, we assessed 354 mycobacterial genome sequences and confirmed that M. chimaera is a phylogenetically coherent group. In silico comparisons indicated six DNA regions present only in M. chimaera We targeted one of these regions and developed a TaqMan quantitative PCR (qPCR) assay for M. chimaera with a detection limit of 100 CFU/ml in whole blood spiked with bacteria. In vitro screening against DNA extracted from 40 other mycobacterial species and 22 bacterial species from 21 diverse genera confirmed the in silico -predicted specificity for M. chimaera Screening 33 water samples from heater-cooler units with this assay highlighted the increased sensitivity of PCR compared to culture, with 15 of 23 culture-negative samples positive by M. chimaera qPCR. We have thus developed a robust molecular assay that can be readily and rapidly deployed to screen clinical and environmental specimens for M. chimaera . Copyright © 2017 American Society for Microbiology.

  19. Evaluation of the Luminex xTAG Respiratory Viral Panel FAST v2 assay for detection of multiple respiratory viral pathogens in nasal and throat swabs in Vietnam

    PubMed Central

    Thi Ty Hang, Vu; Thi Han Ny, Nguyen; My Phuc, Tran; Thi Thanh Tam, Pham; Thao Huong, Dang; Dang Trung Nghia, Ho; Tran Anh Vu, Nguyen; Thi Hong Phuong, Pham; Van Xang, Nguyen; Dong, Nguyen; Nhu Hiep, Pham; Van Hung, Nguyen; Tinh Hien, Tran; Rabaa, Maia; Thwaites, Guy E.; Baker, Stephen; Van Tan, Le; van Doorn, H.Rogier

    2018-01-01

    Background: Acute respiratory infections (ARI) are among the leading causes of hospitalization in children ≤5 years old. Rapid diagnostics of viral pathogens is essential to avoid unnecessary antibiotic treatment, thereby slowing down antibiotic-resistance. We evaluated the diagnostic performance of the Luminex xTAG Respiratory Viral Panel FAST v2 against viral specific PCR as reference assays for ARI in Vietnam. Methods: Four hundred and forty two nose and throat swabs were collected in viral transport medium, and were tested with Luminex xTAG Respiratory Viral Panel FAST v2. Multiplex RT-PCR and single RT-PCR were used as references.    Results: Overall, sensitivity of the Luminex against reference assays was 91.8%, 95% CI 88.1-94.7 (270/294), whilst 112/6336 (1.8%, 95% CI, 1.4-2.1) of pathogens were detected by the Luminex, but not by reference assays. Frequency of pathogens detected by Luminex and reference assays was 379 and 292, respectively. The diagnostic yield was 66.7% (295/442, 95%CI 62.1-71.1%) for the Luminex assay and 54.1% (239/442, 95% CI, 49.3-58.8%) for reference assays. The Luminex kit had higher yields for all viruses except influenza B virus, respiratory syncytial virus, and human bocavirus. High agreements between both methods [mean (range): 0.91 (0.83-1.00)] were found for 10/15 viral agents. Conclusions: The Luminex assay is a high throughput multiplex platform for rapid detection of common viral pathogens causing ARI. Although the current high cost may prevent Luminex assays from being widely used, especially in limited resource settings where ARI are felt most, its introduction in clinical diagnostics may help reduce unnecessary use of antibiotic prescription. PMID:29503874

  20. Development of a fluorescent probe-based recombinase polymerase amplification assay for rapid detection of Orf virus.

    PubMed

    Yang, Yang; Qin, Xiaodong; Wang, Guangxiang; Zhang, Yuen; Shang, Youjun; Zhang, Zhidong

    2015-12-02

    Orf virus (ORFV) is the causative agent of Orf (also known as contagious ecthyma or contagious papular dermatitis), a severe infectious skin disease in goats, sheep and other ruminants. The rapid detection of ORFV is of great importance in disease control and highly needed. A isothermal molecular diagnostic approach, termed recombinase polymerase amplification (RPA), is considered as an novel and rapid alternative techonology to PCR assay. In the present study, a novel fluorescent probe based on RPA assay (ORFV exo RPA assay) was developed. The developed ORFV exo RPA assay was capable of as low as 100 copies of ORFV DNA /reaction and was highly specific, with no cross-reaction with closely related viruses (capripox virus, foot-and-mouth disease virus or peste des petits ruminants virus). Further assessment with clinical samples showed that the developed ORFV exo RPA assay has good correlation with qPCR assays for detection of ORFV. These results suggest that the developed ORFV exo RPA assay is suitable for rapid detection of ORFV.

  1. Comparison of real-time PCR methods for the detection of Naegleria fowleri in surface water and sediment.

    PubMed

    Streby, Ashleigh; Mull, Bonnie J; Levy, Karen; Hill, Vincent R

    2015-05-01

    Naegleria fowleri is a thermophilic free-living ameba found in freshwater environments worldwide. It is the cause of a rare but potentially fatal disease in humans known as primary amebic meningoencephalitis. Established N. fowleri detection methods rely on conventional culture techniques and morphological examination followed by molecular testing. Multiple alternative real-time PCR assays have been published for rapid detection of Naegleria spp. and N. fowleri. Foursuch assays were evaluated for the detection of N. fowleri from surface water and sediment. The assays were compared for thermodynamic stability, analytical sensitivity and specificity, detection limits, humic acid inhibition effects, and performance with seeded environmental matrices. Twenty-one ameba isolates were included in the DNA panel used for analytical sensitivity and specificity analyses. N. fowleri genotypes I and III were used for method performance testing. Two of the real-time PCR assays were determined to yield similar performance data for specificity and sensitivity for detecting N. fowleri in environmental matrices.

  2. Comparison of real-time PCR methods for the detection of Naegleria fowleri in surface water and sediment

    PubMed Central

    Streby, Ashleigh; Mull, Bonnie J.; Levy, Karen

    2015-01-01

    Naegleria fowleri is a thermophilic free-living ameba found in freshwater environments worldwide. It is the cause of a rare but potentially fatal disease in humans known as primary amebic meningoencephalitis. Established N. fowleri detection methods rely on conventional culture techniques and morphological examination followed by molecular testing. Multiple alternative real-time PCR assays have been published for rapid detection of Naegleria spp. and N. fowleri. Four such assays were evaluated for the detection of N. fowleri from surface water and sediment. The assays were compared for thermodynamic stability, analytical sensitivity and specificity, detection limits, humic acid inhibition effects, and performance with seeded environmental matrices. Twenty-one ameba isolates were included in the DNA panel used for analytical sensitivity and specificity analyses. N. fowleri genotypes I and III were used for method performance testing. Two of the real-time PCR assays were determined to yield similar performance data for specificity and sensitivity for detecting N. fowleri in environmental matrices. PMID:25855343

  3. Selected reaction monitoring (SRM) mass spectrometry without isotope labeling can be used for rapid protein quantification

    PubMed Central

    Zhi, Wenbo; Wang, Meiyao

    2014-01-01

    The validation of putative biomarker candidates has become the major bottle-neck in protein biomarker development. Conventional immunoaffinity methods are limited by the availability of antibodies and kits. Here we demonstrated the feasibility of using the selected reaction monitoring (SRM) without isotope labeling to achieve fast and reproducible quantification of serum proteins. The SRM/MRM assays for three standard serum proteins, including ceruloplasmin (CP), serum aymloid A (SAA) and sex hormone binding globulin (SHBG) have good linear ranges, generally 103 – 104. There are almost perfect correlations between SRM intensities and the loaded peptide amounts (R2 is usually ~0.99). Our data suggest that SRM/MRM is able to quantify proteins at 0.2 – 2 fmol level, which are comparable to the commercial ELISA/LUMINEX kits for these proteins. Excellent correlations between SRM/MRM and ELISA/LUMINEX assays were observed for SAA and SHBG (R2 = 0.928 and 0.851 respectively). The correlation between SRM/MRM and ELISA for CP is less desirable (R2 = 0.565). The reproducibility for SRM/MRM assays is generally very good but may depend on the proteins/peptides (R2 = 0.931 and 0.882 for SAA and SHBG, and 0.723 for CP). SRM/MRM assay without isotope labeling is a rapid and useful method for protein biomarker validation in a modest number of samples and is especially useful when other assays such as ELISA or Luminex beads are not available. PMID:21594933

  4. Concentration Gradient Immunoassay I. A Rapid Immunoassay Based on Interdiffusion and Surface Binding in a Microchannel

    PubMed Central

    Nelson, Kjell E.; Foley, Jennifer O.; Yager, Paul

    2008-01-01

    We describe a novel microfluidic immunoassay method based on the diffusion of a small molecule analyte into a parallel-flowing stream containing cognate antibody. This interdiffusion results in a steady-state gradient of antibody binding site occupancy transverse to convective flow. In contrast to the diffusion immunoassay (Hatch et al. Nature Biotechnology,19:461−465 (2001)), this antibody occupancy gradient is interrogated by a sensor surface coated with a functional analog of the analyte. Antibodies with at least one unoccupied binding site may specifically bind to this functionalized surface, leading to a quantifiable change in surface coverage by the antibody. SPR imaging is used to probe the spatial distribution of antibody binding to the surface and, therefore, the outcome of the assay. We show that the pattern of antibody binding to the SPR sensing surface correlates with the concentration of a model analyte (phenytoin) in the sample stream. Using an inexpensive disposable microfluidic device, we demonstrate assays for phenytoin ranging in concentration from 75 to 1000 nM in phosphate buffer. At a total volumetric flow rate of 90 nL/sec, the assays are complete within 10 minutes. Inclusion of an additional flow stream on the side of the antibody stream opposite to that of the sample enables simultaneous calibration of the assay. This assay method is suitable for rapid quantitative detection of low-molecular weight analytes for point-of-care diagnostic instrumentation. PMID:17437332

  5. Rapid colorimetric sensing of tetracycline antibiotics with in situ growth of gold nanoparticles.

    PubMed

    Shen, Li; Chen, Jing; Li, Na; He, Pingli; Li, Zhen

    2014-08-11

    A colorimetric assay utilizing the formation of gold nanoparticles was developed to detect tetracycline antibiotics in fluidic samples. Tetracycline antibiotics showed the capability of directly reducing aurate salts into atomic gold which form gold nanoparticles spontaneously under proper conditions. The resulted gold nanoparticles showed characteristic plasmon absorbance at 526 nm, which can be visualized by naked eyes or with a spectrophotometer. UV-vis absorbance of the resulted gold nanoparticles is correlated directly with the concentrations of tetracycline antibiotics in the solution, allowing for quantitative colorimetric detection of tetracycline antibiotics. Reaction conditions, such as pH, temperature, reaction time, and ionic strength were optimized. Sensitivity of the colorimetric assay can be enhanced by the addition of gold nanoparticle seeds, a LOD as low as 20 ng mL(-1) can be achieved with the help of seed particles. The colorimetric assay showed minimum interference from ethanol, methanol, urea, glucose, and other antibiotics such as sulfonamides, amino glycosides etc. Validity of the method was also evaluated on urine samples spiked with tetracycline antibiotics. The method provides a broad spectrum detection method for rapid and sensitive detection of reductive substances such as tetracycline antibiotics in liquid and biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Rapid and sensitive detection of Lily symptomless virus by reverse transcription loop-mediated isothermal amplification.

    PubMed

    He, Xiangfeng; Xue, Fei; Xu, Shufa; Wang, Wenhe

    2016-12-01

    Lily symptomless virus (LSV) is one of the most prevalent viruses that infect lily plants worldwide. A rapid and sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for detection of LSV, using two primer pairs that specifically amplified the conserved sequence of LSV coat protein. The optimum reaction conditions were as follows: 4mM MgCl 2 and 0.8M betaine with incubation at 64°C for 30min. The limit of detection of LSV from infected lily leaves was 10-fold higher for RT-LAMP than for conventional RT-PCR. Moreover, RT-LAMP detected LSV in not only symptomatic, but also in symptomless tissues of infected plants. These findings indicate that our RT-LAMP method for LSV can serve as a low-cost, simple, and rapid alternative to conventional detection assays. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Development of SCAR markers and UP-PCR cross-hybridization method for specific detection of four major subgroups of Rhizoctonia from infected turfgrasses

    USDA-ARS?s Scientific Manuscript database

    Several species and hyphal anastomosis groups (AG) of Rhizoctonia solani (sensu lato) cause brown patch diseases of turfgrasses. Conventional methods of identification of Rhizoctonia pathogens are time consuming and often inaccurate. A rapid identification assay for Waitea circinata (anamorph: Rhizo...

  8. A rapid and cost effective method for soil carbon mineralization under static incubations

    USDA-ARS?s Scientific Manuscript database

    Soil incubations with subsequent measurement of carbon dioxide (CO2) evolved are common soil assays to estimate C mineralization rates and active organic C. Two common methods used to detect CO2 in laboratory incubations are gas chromatography (GC) and alkali absorption followed by titration (NaOH)...

  9. A rapid spectrophotometric method to determine B-carotene content in Cucumis melo germplasm

    USDA-ARS?s Scientific Manuscript database

    The compound B -carotene is the predominant carotenoid in cantaloupe. Because of its antioxidant properties and health benefits, B-carotene content in fruits and vegetables is of interest to the food industry. Current methods to assay B-carotene content in fruit are time consuming, expensive and u...

  10. A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin

    NASA Astrophysics Data System (ADS)

    Sung, Tzu-Cheng; Chen, Wen-Yih; Shah, Pramod; Chen, Chien-Sheng

    2016-02-01

    Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replacement assay is a competitive assay where a sample analyte replaces the labeled competitor of analyte out of its biorecognition element on a surface. It is user friendly and time-saving because of washing free. We used aptamer as a competitor, not a biorecognition element as tradition. To label aptamers, we used cholesterol-conjugated aptamers to tag signal-amplifying-liposomes. Without the need of conjugation procedure, aptamers can be easily incorporated into the surface of dye-encapsulating liposomes. Two aptamers as competitors of biotin, ST-21 and ST-21M with different affinities to streptavidin, were studied in parallel for the detection of biotin using replacement assays. ST-21 and ST-21M aptamers reached to limits of detection of 1.32 pg/80 μl and 0.47 pg/80 μl, respectively. The dynamic ranges of our assays using ST-21 and ST-21M aptamers were seven and four orders of magnitude, respectively. This assay can be completed in 20 minutes without washing steps. These results were overall better than previous reported assays.

  11. Development of a reverse transcription quantitative polymerase chain reaction-based assay for broad coverage detection of African and Asian Zika virus lineages.

    PubMed

    Yang, Yang; Wong, Gary; Ye, Baoguo; Li, Shihua; Li, Shanqin; Zheng, Haixia; Wang, Qiang; Liang, Mifang; Gao, George F; Liu, Lei; Liu, Yingxia; Bi, Yuhai

    2017-06-01

    The Zika virus (ZIKV) is an arbovirus that has spread rapidly worldwide within recent times. There is accumulating evidence that associates ZIKV infections with Guillain-Barré Syndrome (GBS) and microcephaly in humans. The ZIKV is genetically diverse and can be separated into Asian and African lineages. A rapid, sensitive, and specific assay is needed for the detection of ZIKV across various pandemic regions. So far, the available primers and probes do not cover the genetic diversity and geographic distribution of all ZIKV strains. To this end, we have developed a one-step quantitative reverse transcription polymerase chain reaction (qRT-PCR) assay based on conserved sequences in the ZIKV envelope (E) gene. The detection limit of the assay was determined to be five RNA transcript copies and 2.94 × 10 -3 50% tissue culture infectious doses (TCID 50 ) of live ZIKV per reaction. The assay was highly specific and able to detect five different ZIKV strains covering the Asian and African lineages without nonspecific amplification, when tested against other flaviviruses. The assay was also successful in testing for ZIKV in clinical samples. Our assay represents an improvement over the current methods available for the detection ZIKV and would be valuable as a diagnostic tool in various pandemic regions.

  12. Simultaneous cytofluorometric measurement of phagocytosis, burst production and killing of human phagocytes using Candida albicans and Staphylococcus aureus as target organisms.

    PubMed

    Salih, H R; Husfeld, L; Adam, D

    2000-05-01

    Polymorphonuclear leukocytes (PMN) play a central role in the elimination of most extracellular pathogens, and an impairment of their functions predisposes an individual towards local and systemic bacterial and fungal infections. Here we describe a rapid and easy-to-perform cytofluorometric assay for investigation of PMN activity using Candida albicans and Staphylococcus aureus as target organisms. Phagocytes were stained with anti-CD13-RPE antibody, and microorganisms were stained with calcein-AM. Oxidative burst production was measured by oxidation of dihydroethidium. The percentage of killed target organisms after ingestion was determined by staining with ethidium-homodimer-1 after lysis of human cells. The dyes and procedures used in this method were chosen after comparison of different stains and cell preparation techniques described in previous assays. Concerning phagocytosis, the percentages of active phagocytes and of ingested microorganisms were determined. Furthermore, the method allowed measurement of the resulting percentage of PMNs producing respiratory burst, and of the percentage of killed microorganisms. We minimized artifactual changes, which might have been the reason for the difficulties and conflicting results of other cytofluorometric methods. The described method provides a new whole blood cytofluorometric assay, which combines rapid and simple handling with high reproducibility of results obtained by investigation of PMN activity using Candida albicans and Staphylococcus aureus as target organisms.

  13. Development of a rapid and visual nucleotide detection method for a Chinese epidemic strain of Orientia tsutsugamushi based on recombinase polymerase amplification assay and lateral flow test.

    PubMed

    Qi, Yong; Yin, Qiong; Shao, Yinxiu; Cao, Min; Li, Suqin; Chen, Hongxia; Shen, Wanpeng; Rao, Jixian; Li, Jiameng; Li, Xiaoling; Sun, Yu; Lin, Yu; Deng, Yi; Zeng, Wenwen; Zheng, Shulong; Liu, Suyun; Li, Yuexi

    2018-05-01

    Orientia tsutsugamushi is an obligate intracellular pathogen that causes scrub typhus. Diagnosing scrub typhus remains a challenge, and a sensitive, specific, simple, and rapid diagnostic test is still needed. A recombinase polymerase amplification (RPA) assay combined with a lateral flow (LF) test targeting the 56-kDa gene of a Karp-like strain of O. tsutsugamushi was developed and optimized. The detection limits, sensitivity, specificity, and simulative clinical performance were evaluated. Primers and probe were screened to establish the RPA assay, and the reaction conditions were optimized. The detection limit was 10 copies/reaction in detecting plasmid DNA and 12 copies/reaction in detecting genomic DNA. The RPA-LF method could differentiate O. tsutsugamushi from other phylogenetically related bacteria. The sensitivity was 100% and specificity was over 90%, when evaluated using infected animal samples or simulative clinical samples. Furthermore, the method was completed in 20min at 37°C followed by a 3-5min incubation at room temperature for the development of an immunochromatographic strip, and the results could be determined visually. This method is promising for wide-ranging use in basic medical units considering that it requires minimal instruments and infrastructure and is highly time-efficient, sensitive, and specific for diagnosing scrub typhus. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Development of a rapid loop-mediated isothermal amplification assay for diagnosis and assessment of cure of Leishmania infection.

    PubMed

    Verma, Sandeep; Singh, Ruchi; Sharma, Vanila; Bumb, Ram Avtar; Negi, Narendra Singh; Ramesh, V; Salotra, Poonam

    2017-03-23

    Leishmaniasis is a spectrum of diseases with great relevance to public health. Conventional diagnostic methods are time consuming, needing trained personnel. A robust, rapid and cost effective diagnostic test is warranted for on-time diagnosis and field application. We have developed a loop mediated isothermal amplification (LAMP) assay with primers (n = 6) based on Leishmania donovani kDNA for detection of Leishmania infection, using a closed tube to prevent cross-contamination. The assay was used to detect Leishmania infection in biological samples obtained from patients of visceral leishmaniasis (VL), post kala-azar dermal leishmaniasis (PKDL) and cutaneous leishmaniasis (CL). The assay was positive for L. donovani, L. tropica and L. major parasites, with the highest sensitivity towards L. donovani (1 fg DNA). The high sensitivity of the assay for detection of L. donovani was reflected in its ability to detect parasite DNA within 30 min of amplification time with a threshold detection limit of ≥25 copies per reaction. The assay detected parasite in 64 of 66 VL blood samples (sensitivity, 96.9%; 95% CI: 89.6-99.2%), 15 of 15 VL bone marrow aspirate samples (sensitivity, 100%; 95% CI:79.6-100%), 65 of 67 PKDL tissue biopsy samples (sensitivity, 97%; 95% CI:89.7-99.2%). The assay was evaluated in a few cases of CL wherein it was found positive in 8 of 10 tissue biopsies (sensitivity, 80%; 95% CI: 49-94.3%). The assay was negative in all control blood (n = 76) and tissue biopsy (n = 24) samples (specificity, 100%; 95% CI: 96.3-100%). Further, the assay was evaluated for its utility in assessment of cure in treated VL and PKDL patients. The assay detected parasite DNA in 2 of 20VL blood samples and 2 of 21 PKDL tissue samples. Out of 4 cases that were positive for parasite DNA at post treatment stage, 2 patients (1VL and 1 PKDL) returned with relapse. The study demonstrated a Leishmania genus specific closed tube LAMP assay for reliable and rapid molecular diagnosis of VL and PKDL with potential for application in assessment of cure.

  15. Development of a F actin-based live-cell fluorimetric microplate assay for diarrhetic shellfish toxins.

    PubMed

    Leira, F; Alvarez, C; Cabado, A G; Vieites, J M; Vieytes, M R; Botana, L M

    2003-06-15

    A new cytotoxicity assay for detection and quantitation of diarrhetic shellfish toxins (DSP) is presented. This assay is based upon fluorimetric determination of F-actin depolymerization induced by okadaic acid (OA)-class compounds in the BE(2)-M17 neuroblastoma cell line. No interferences were observed with other marine toxins such as saxitoxin, domoic acid, or yessotoxin, thus indicating a good specificity of the assay as expected by the direct relationship between protein phosphatase inhibition and cytoskeletal changes. The proposed method is rapid (<2h) and shows a linear response in the range of 50-300 nM OA. The detection limit of the assay for crude methanolic extracts of bivalves lies between 0.2 and 1.0 microg OA per gram of digestive glands, depending on the type of samples (fresh or canned), thus being similar to that of the mouse bioassay. The performance of this assay has been evaluated by comparative analysis of 32 toxic mussel samples by the F-actin assay, mouse bioassay, HPLC and PP2A inhibition assay. Results obtained by the F-actin method showed no differences with HPLC and significant correlation with PP2A inhibition assay (r(2)=0.71). No false negative results were obtained with this new cell assay, which also showed optimum reproducibility.

  16. A biosensor platform for rapid detection of E. coli in drinking water.

    PubMed

    Hesari, Nikou; Alum, Absar; Elzein, Mohamad; Abbaszadegan, Morteza

    2016-02-01

    There remains a need for rapid, specific and sensitive assays for the detection of bacterial indicators for water quality monitoring. In this study, a strategy for rapid detection of Escherichia coli in drinking water has been developed. This strategy is based on the use of the substrate 4-methylumbelliferyl-β-d-glucuronide (MUG), which is hydrolyzed rapidly by the action of E. coli β-d-glucuronidase (GUD) enzyme to yield a fluorogenic 4-methylumbelliferone (4-MU) product that can be quantified and related to the number of E. coli cells present in water samples. In this study, the detection time required for the biosensor response ranged between 20 and 120 min, depending on the number of bacteria in the sample. This approach does not need extensive sample processing with a rapid detection capability. The specificity of the MUG substrate was examined in both, pure cultures of non-target bacterial genera such as Klebsiella, Salmonella, Enterobacter and Bacillus. Non-target substrates that included 4-methylumbelliferyl-β-d-galactopyranoside (MUGal) and l-leucine β-naphthylamide aminopeptidase (LLβ-N) were also investigated to identify nonspecific patterns of enzymatic activities in E. coli. GUD activity was found to be specific for E. coli and no further enzymatic activity was detected by other species. In addition, fluorescence assays were performed for the detection of E. coli to generate standard curves; and the sensitivity of the GUD enzymatic response was measured and repeatedly determined to be less than 10 E. coli cells in a reaction vial. The applicability of the method was tested by performing multiple fluorescence assays under pure and mixed bacterial flora in environmental samples. The results of this study showed that the fluorescence signals generated in samples using specific substrate molecules can be utilized to develop a bio-sensing platform for the detection of E. coli in drinking water. Furthermore, this system can be applied independently or in conjunction with other methods as a part of an array of biochemical assays in order to reliably detect E. coli in water. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Detection of shigella in lettuce by the use of a rapid molecular assay with increased sensitivity

    PubMed Central

    Jiménez, Kenia Barrantes; McCoy², Clyde B.; Achí, Rosario

    2010-01-01

    A Multiplex Polymerase Chain Reaction (PCR) assay to be used as an alternative to the conventional culture method in detecting Shigella and enteroinvasive Escherichia coli (EIEC) virulence genes ipaH and ial in lettuce was developed. Efficacy and rapidity of the molecular method were determined as compared to the conventional culture. Lettuce samples were inoculated with different Shigella flexneri concentrations (from 10 CFU/ml to 107 CFU/ml). DNA was extracted directly from lettuce after inoculation (direct-PCR) and after an enrichment step (enrichment PCR). Multiplex PCR detection limit was 104CFU/ml, diagnostic sensitivity and specificity were 100% accurate. An internal amplification control (IAC) of 100 bp was used in order to avoid false negative results. This method produced results in 1 to 2 days while the conventional culture method required 5 to 6 days. Also, the culture method detection limit was 106 CFU/ml, diagnostic sensitivity was 53% and diagnostic specificity was 100%. In this study a Multiplex PCR method for detection of virulence genes in Shigella and EIEC was shown to be effective in terms of diagnostic sensitivity, detection limit and amount of time as compared to Shigella conventional culture. PMID:24031579

  18. Rapid Detection of Candida albicans by Polymerase Spiral Reaction Assay in Clinical Blood Samples

    PubMed Central

    Jiang, Xiaoqun; Dong, Derong; Bian, Lihong; Zou, Dayang; He, Xiaoming; Ao, Da; Yang, Zhan; Huang, Simo; Liu, Ningwei; Liu, Wei; Huang, Liuyu

    2016-01-01

    Candida albicans is the most common human yeast pathogen which causes mucosal infections and invasive fungal diseases. Early detection of this pathogen is needed to guide preventative and therapeutic treatment. The aim of this study was to establish a polymerase spiral reaction (PSR) assay that rapidly and accurately detects C. albicans and to assess the clinical applicability of PSR-based diagnostic testing. Internal transcribed spacer 2 (ITS2), a region between 5.8S and 28S fungal ribosomal DNA, was used as the target sequence. Four primers were designed for amplification of ITS2 with the PSR method, which was evaluated using real time turbidity monitoring and visual detection using a pH indicator. Fourteen non-C. albicans yeast strains were negative for detection, which indicated the specificity of PSR assay was 100%. A 10-fold serial dilution of C. albicans genomic DNA was subjected to PSR and conventional polimerase chain reaction (PCR) to compare their sensitivities. The detection limit of PSR was 6.9 pg/μl within 1 h, 10-fold higher than that of PCR (69.0 pg/μl). Blood samples (n = 122) were collected from intensive care unit and hematological patients with proven or suspected C. albicans infection at two hospitals in Beijing, China. Both PSR assay and the culture method were used to analyze the samples. Of the 122 clinical samples, 34 were identified as positive by PSR. The result was consistent with those obtained by the culture method. In conclusion, a novel and effective C. albicans detection assay was developed that has a great potential for clinical screening and point-of-care testing. PMID:27379048

  19. Quantitative PCR for Genetic Markers of Human Fecal Pollution

    EPA Science Inventory

    Assessment of health risk and fecal bacteria loads associated with human fecal pollution requires reliable host-specific analytical methods and a rapid quantificationapproach. We report the development of quantitative PCR assays for quantification of two recently described human-...

  20. In vitro detection and quantification of botulinum neurotoxin type E activity in avian blood

    USGS Publications Warehouse

    Piazza, T.M.; Blehert, D.S.; Dunning, F.M.; Berlowski-Zier, B. M.; Zeytin, F.N.; Samuel, M.D.; Tucker, W.C.

    2011-01-01

    Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by F??rster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity. ?? 2011, American Society for Microbiology.

  1. Development of a polymerase chain reaction assay for the detection of pseudorabies virus in clinical samples

    PubMed Central

    Pérez, Lester J.; de Arce, Heidy Díaz

    2009-01-01

    Aujeszky’s disease, also known as pseudorabies causes severe economic losses in swine industry and affects the pig husbandry all over the world. The conventional diagnostic procedure is time-consuming and false-negative results may occur in submissions from latently infected animals. The development, optimization and evaluation of a polymerase chain reaction (PCR) assay are presented for the diagnosis of pseudorabies infection. This assay was based on the amplification of a highly conserved viral gD gene fragment. PCR products of the expected size were obtained from PRV strains. Non-specific reactions were not observed when a related herpesvirus, other porcine DNA genome viruses and uninfected cells were used to assess PCR. The analytical sensitivity of the test was estimated to be 1.34 TCID50/ 50 uL. The analysis of tissue homogenate samples from naturally infected animals proved the potential usefulness of the method for a rapid disease diagnosis from field cases. A rapid, sensitive and specific PCR-based diagnostic assay to detect pseudorabies virus in clinical samples is provided. PMID:24031383

  2. In vitro detection and quantification of botulinum neurotoxin type E activity in avian blood

    USGS Publications Warehouse

    Piazza, Timothy M.; Blehert, David S.; Dunning, F. Mark; Berlowski-Zier, Brenda M.; Zeytin, Fusun N.; Samuel, Michael D.; Tucker, Ward C.

    2011-01-01

    Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by Förster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity.

  3. A rapid non-radioactive technique for measurement of repair synthesis in primary human fibroblasts by incorporation of ethynyl deoxyuridine (EdU).

    PubMed

    Limsirichaikul, Siripan; Niimi, Atsuko; Fawcett, Heather; Lehmann, Alan; Yamashita, Shunichi; Ogi, Tomoo

    2009-03-01

    Xeroderma pigmentosum (XP) is an autosomal recessive genetic disorder. Afflicted patients show extreme sun-sensitivity and skin cancer predisposition. XP is in most cases associated with deficient nucleotide excision repair (NER), which is the process responsible for removing photolesions from DNA. Measuring NER activity by nucleotide incorporation into repair patches, termed 'unscheduled DNA synthesis (UDS)', is one of the most commonly used assays for XP-diagnosis and NER research. We have established a rapid and accurate procedure for measuring UDS by replacement of thymidine with 5-ethynyl-2'-deoxyuridine (EdU). EdU incorporated into repair patches can be directly conjugated to fluorescent azide derivatives, thereby obviating the need for either radiolabeled thymidine or denaturation and antibody detection of incorporated bromodeoxyuridine (BrdU). We demonstrate that the EdU incorporation assay is compatible with conventional techniques such as immunofluorescent staining and labeling of cells with micro-latex beads. Importantly, we can complete the entire UDS assay within half a day from preparation of the assay coverslips; this technique may prove useful as a method for XP diagnosis.

  4. Multiplex qPCR for reliable detection and differentiation of Burkholderia mallei and Burkholderia pseudomallei.

    PubMed

    Janse, Ingmar; Hamidjaja, Raditijo A; Hendriks, Amber C A; van Rotterdam, Bart J

    2013-02-14

    Burkholderia mallei and B. pseudomallei are two closely related species of highly virulent bacteria that can be difficult to detect. Pathogenic Burkholderia are endemic in many regions worldwide and cases of infection, sometimes brought by travelers from unsuspected regions, also occur elsewhere. Rapid, sensitive methods for identification of B. mallei and B. pseudomallei are urgently needed in the interests of patient treatment and epidemiological surveillance. Signature sequences for sensitive, specific detection of pathogenic Burkholderia based on published genomes were identified and a qPCR assay was designed and validated. A single-reaction quadruplex qPCR assay for the detection of pathogenic Burkholderia, which includes a marker for internal control of DNA extraction and amplification, was developed. The assay permits differentiation of B. mallei and B. pseudomallei strains, and probit analysis showed a very low detection limit. Use of a multicopy signature sequence permits detection of less than 1 genome equivalent per reaction. The new assay permits rapid detection of pathogenic Burkholderia and combines enhanced sensitivity, species differentiation, and inclusion of an internal control for both DNA extraction and PCR amplification.

  5. In Vitro Detection and Quantification of Botulinum Neurotoxin Type E Activity in Avian Blood▿

    PubMed Central

    Piazza, Timothy M.; Blehert, David S.; Dunning, F. Mark; Berlowski-Zier, Brenda M.; Zeytin, Füsûn N.; Samuel, Michael D.; Tucker, Ward C.

    2011-01-01

    Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by Förster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity. PMID:21908624

  6. Detection of Campylobacter jejuni added to foods by using a combined selective enrichment and nucleic acid sequence-based amplification (NASBA).

    PubMed Central

    Uyttendaele, M; Schukkink, R; van Gemen, B; Debevere, J

    1995-01-01

    An assay to detect Campylobacter jejuni in foods that uses a short selective enrichment culture, a simple and rapid isolation procedure, NASBA amplification of RNA, and a nonradioactive in solution hybridization was studied. The presence of high numbers of indigenous flora affected the sensitivity of the assay. However, detection of C. jejuni was possible up to a ratio of indigenous flora to C. jejuni of 10,000:1. Interference by food components was eliminated by centrifugation following the enrichment step. Fourteen food samples artificially inoculated with C. jejuni (1 to 1,000 CFU/10 g) were analyzed with the NASBA assay and the conventional culture method with Campylobacter charcoal differential agar (CCDA). A few false-negative results were obtained by both NASBA (1.42%) and CCDA (2.86%) isolation. Yet the use of enrichment culture and NASBA shortened the analysis time from 6 days to 26 h. The relative simplicity and rapidity of the NASBA assay make it an attractive alternative for detection of C. jejuni in food samples. PMID:7747955

  7. Cell-based flavivirus infection (CFI) assay for the evaluation of dengue antiviral candidates using high-content imaging.

    PubMed

    Tan, Kah Hin; Ki, Kitti Chan Wing; Watanabe, Satoru; Vasudevan, Subhash G; Krishnan, Manoj

    2014-01-01

    Large-scale screening of antiviral compounds that target dengue virus life cycle requires a robust cell-based assay that is rapid, easy to conduct, and sensitive enough to be able to assess viral infectivity and cell viability so that antiviral efficacy can be measured. In this chapter we describe a method that uses high-content imaging to evaluate the in vitro antiviral efficacy in a modification to the cell-based flavivirus immunodetection (CFI) assay that was described previously in Wang et al. (Antimicrob Agents Chemother 53(5):1823-1831, 2009).

  8. Quantification of protein concentration using UV absorbance and Coomassie dyes.

    PubMed

    Noble, James E

    2014-01-01

    The measurement of a solubilized protein concentration in solution is an important assay in biochemistry research and development labs for applications ranging from enzymatic studies to providing data for biopharmaceutical lot release. Spectrophotometric protein quantification assays are methods that use UV and visible spectroscopy to rapidly determine the concentration of protein, relative to a standard, or using an assigned extinction coefficient. Where multiple samples need measurement, and/or the sample volume and concentration is limited, preparations of the Coomassie dye commonly known as the Bradford assay can be used. © 2014 Elsevier Inc. All rights reserved.

  9. A new methodology for rapid detection of Lactobacillus delbrueckii subsp. bulgaricus based on multiplex PCR.

    PubMed

    Nikolaou, Anastasios; Saxami, Georgia; Kourkoutas, Yiannis; Galanis, Alex

    2011-02-01

    In this study we present a novel multiplex PCR assay for rapid and efficient detection of Lactobacillus delbrueckii subsp. bulgaricus. The accuracy of our method was confirmed by the successful identification of L. delbrueckii subsp. bulgaricus in commercial yoghurts and food supplements and it may be readily applied to the food industry. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Application of laboratory and portable attenuated total reflectance infrared spectroscopic approaches for rapid quantification of alpaca serum immunoglobulin G

    PubMed Central

    Burns, Jennifer B.; Riley, Christopher B.; Shaw, R. Anthony; McClure, J. Trenton

    2017-01-01

    The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR) spectroscopic approaches in combination with partial least squares regression (PLSR) for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL), which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI) in neonates. Serum samples (n = 175) collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID) assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training) and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set). Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for potential application in the field. PMID:28651006

  11. Application of laboratory and portable attenuated total reflectance infrared spectroscopic approaches for rapid quantification of alpaca serum immunoglobulin G.

    PubMed

    Elsohaby, Ibrahim; Burns, Jennifer B; Riley, Christopher B; Shaw, R Anthony; McClure, J Trenton

    2017-01-01

    The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR) spectroscopic approaches in combination with partial least squares regression (PLSR) for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL), which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI) in neonates. Serum samples (n = 175) collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID) assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training) and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set). Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for potential application in the field.

  12. Low-cost fluorimetric determination of radicals based on fluorogenic dimerization of the natural phenol sesamol.

    PubMed

    Makino, Yumi; Uchiyama, Seiichi; Ohno, Ken-ichi; Arakawa, Hidetoshi

    2010-02-15

    A novel fluorimetric method for determining radicals using the natural phenol sesamol as a fluorogenic reagent is reported. In this assay, sesamol was reacted with aqueous radicals to yield one isomer of a sesamol dimer exclusively. The dimer emitted purple fluorescence near 400 nm around neutral pH, where it assumed the monoanionic form. This method was applied to the straightforward detection of radical nitric oxide (NO). The ready availability of sesamol should enable rapid implementation of applications utilizing this new assay, particularly in high-throughput analysis or screening.

  13. Rapid detection and subtyping of human influenza A viruses and reassortants by pyrosequencing.

    PubMed

    Deng, Yi-Mo; Caldwell, Natalie; Barr, Ian G

    2011-01-01

    Given the continuing co-circulation of the 2009 H1N1 pandemic influenza A viruses with seasonal H3N2 viruses, rapid and reliable detection of newly emerging influenza reassortant viruses is important to enhance our influenza surveillance. A novel pyrosequencing assay was developed for the rapid identification and subtyping of potential human influenza A virus reassortants based on all eight gene segments of the virus. Except for HA and NA genes, one universal set of primers was used to amplify and subtype each of the six internal genes. With this method, all eight gene segments of 57 laboratory isolates and 17 original specimens of seasonal H1N1, H3N2 and 2009 H1N1 pandemic viruses were correctly matched with their corresponding subtypes. In addition, this method was shown to be capable of detecting reassortant viruses by correctly identifying the source of all 8 gene segments from three vaccine production reassortant viruses and three H1N2 viruses. In summary, this pyrosequencing assay is a sensitive and specific procedure for screening large numbers of viruses for reassortment events amongst the commonly circulating human influenza A viruses, which is more rapid and cheaper than using conventional sequencing approaches.

  14. Rapid Detection and Subtyping of Human Influenza A Viruses and Reassortants by Pyrosequencing

    PubMed Central

    Deng, Yi-Mo; Caldwell, Natalie; Barr, Ian G.

    2011-01-01

    Background Given the continuing co-circulation of the 2009 H1N1 pandemic influenza A viruses with seasonal H3N2 viruses, rapid and reliable detection of newly emerging influenza reassortant viruses is important to enhance our influenza surveillance. Methodology/Principal Findings A novel pyrosequencing assay was developed for the rapid identification and subtyping of potential human influenza A virus reassortants based on all eight gene segments of the virus. Except for HA and NA genes, one universal set of primers was used to amplify and subtype each of the six internal genes. With this method, all eight gene segments of 57 laboratory isolates and 17 original specimens of seasonal H1N1, H3N2 and 2009 H1N1 pandemic viruses were correctly matched with their corresponding subtypes. In addition, this method was shown to be capable of detecting reassortant viruses by correctly identifying the source of all 8 gene segments from three vaccine production reassortant viruses and three H1N2 viruses. Conclusions/Significance In summary, this pyrosequencing assay is a sensitive and specific procedure for screening large numbers of viruses for reassortment events amongst the commonly circulating human influenza A viruses, which is more rapid and cheaper than using conventional sequencing approaches. PMID:21886790

  15. A rapid and sensitive assay method for measuring amine oxidase based on hydrogen peroxide-titanium complex formation.

    PubMed

    Nag; Saha; Choudhuri

    2000-08-22

    Hydrogenperoxide (H(2)O(2)) is an end product of diamine and polyamine oxidation by their respective oxidase enzymes. A new sensitive assay method is based on a H(2)O(2)-titanium (Ti) complex formation as an indicator of H(2)O(2) production due to polyamine oxidation. The orange-yellow coloured H(2)O(2)-Ti complex was measured at 410 nm in a Shimadzu spectrophotometer. The assay conditions for maximum diamine oxidase (DAO) and polyamine oxidase (PAO) as standardized here using the hypocotyl tissues of Vigna catjang Endl. cv Pusa Barsati consisted of pH 7.4 (40 mM potassium phosphate buffer), 3 mM substrate (putrescine or spermine), 37 degrees C incubation temperature and 30 min incubation time in the presence of catechol (10(-2) M) used as an inhibitor of both peroxidase and catalase activity. The method described here was significantly more sensitive than the starch-iodide method [T.A. Smith, Biochem. Biophys. Res. Commun. 41 (1970) 1452-1456], which could be improved further if measured under the same assay conditions as described for the H(2)O(2)-Ti method. Sensitivity of the present method was tested by assaying DAO/PAO activity in auxin treated hypocotyls of Vigna and comparing it with the starch-iodide method in two other plant samples.

  16. Development and evaluation of a blocking enzyme-linked immunosorbent assay and virus neutralization assay to detect antibodies to viral hemorrhagic septicemia virus

    USGS Publications Warehouse

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas M.; Toohey-Kurth, Kathy

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV.

  17. Therapeutic Drug Monitoring of Phenytoin by Simple, Rapid, Accurate, Highly Sensitive and Novel Method and Its Clinical Applications.

    PubMed

    Shaikh, Abdul S; Guo, Ruichen

    2017-01-01

    Phenytoin has very challenging pharmacokinetic properties. To prevent its toxicity and ensure efficacy, continuous therapeutic monitoring is required. It is hard to get a simple, accurate, rapid, easily available, economical and highly sensitive assay in one method for therapeutic monitoring of phenytoin. The present study is directed towards establishing and validating a simpler, rapid, an accurate, highly sensitive, novel and environment friendly liquid chromatography/mass spectrometry (LC/MS) method for offering rapid and reliable TDM results of phenytoin in epileptic patients to physicians and clinicians for making immediate and rational decision. 27 epileptics patients with uncontrolled seizures or suspected of non-compliance or toxicity of phenytoin were selected and advised for TDM of phenytoin by neurologists of Qilu Hospital Jinan, China. The LC/MS assay was used for performing of therapeutic monitoring of phenytoin. The Agilent 1100 LC/MS system was used for TDM. The mixture of Ammonium acetate 5mM: Methanol at (35: 65 v/v) was used for the composition of mobile phase. The Diamonsil C18 (150mm×4.6mm, 5μm) column was used for the extraction of analytes in plasma. The samples were prepared with one step simple protein precipitation method. The technique was validated with the guidelines of International Conference on Harmonisation (ICH). The calibration curve demonstrated decent linearity within (0.2-20 µg/mL) concentration range with linearity equation, y= 0.0667855 x +0.00241785 and correlation coefficient (R2) of 0.99928. The specificity, recovery, linearity, accuracy, precision and stability results were within the accepted limits. The concentration of 0.2 µg/mL was observed as lower limit of quantitation (LLOQ), which is 12.5 times lower than the currently available enzyme-multiplied immunoassay technique (EMIT) for measurement of phenytoin in epilepsy patients. A rapid, simple, economical, precise, highly sensitive and novel LC/MS assay has been established, validated and applied successfully in TDM of 27 epileptics patients. It was alarmingly found that TDM results of all these patients were out of safe range except two patients. However, it needs further evaluation. Besides TDM, the stated method can also be applied in bioequivalence, pharmacokinetics, toxicokinetics and pharmacovigilance studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Surface enhanced Raman spectroscopy based nanoparticle assays for rapid, point-of-care diagnostics

    NASA Astrophysics Data System (ADS)

    Driscoll, Ashley J.

    Nucleotide and immunoassays are important tools for disease diagnostics. Many of the current laboratory-based analytical diagnostic techniques require multiple assay steps and long incubation times before results are acquired. In the development of bioassays designed for detecting the emergence and spread of diseases in point-of-care (POC) and remote settings, more rapid and portable analytical methods are necessary. Nanoparticles provide simple and reproducible synthetic methods for the preparation of substrates that can be applied in colloidal assays, providing gains in kinetics due to miniaturization and plasmonic substrates for surface enhanced spectroscopies. Specifically, surface enhanced Raman spectroscopy (SERS) is finding broad application as a signal transduction method in immunological and nucleotide assays due to the production of narrow spectral peaks from the scattering molecules and the potential for simultaneous multiple analyte detection. The application of SERS to a no-wash, magnetic capture assay for the detection of West Nile Virus Envelope and Rift Valley Fever Virus N antigens is described. The platform utilizes colloid based capture of the target antigen in solution, magnetic collection of the immunocomplexes and acquisition of SERS spectra by a handheld Raman spectrometer. The reagents for a core-shell nanoparticle, SERS based assay designed for the capture of target microRNA implicated in acute myocardial infarction are also characterized. Several new, small molecule Raman scatterers are introduced and used to analyze the enhancing properties of the synthesized gold coated-magnetic nanoparticles. Nucleotide and immunoassay platforms have shown improvements in speed and analyte capture through the miniaturization of the capture surface and particle-based capture systems can provide a route to further surface miniaturization. A reaction-diffusion model of the colloidal assay platform is presented to understand the interplay of system parameters such as particle diameter, initial analyte concentration and dissociation constants. The projected sensitivities over a broad range of assay conditions are examined and the governing regime of particle systems reported. The results provide metrics in the design of more robust analytics that are of particular interest for POC diagnostics.

  19. Influence of 2 cryopreservation methods to induce CCL-13 from dental pulp cells.

    PubMed

    Ahn, Su-Jin; Jang, Ji-Hyun; Seo, Ji-Sung; Cho, Kyu Min; Jung, Su-Hee; Lee, Hyeon-Woo; Kim, Eun-Cheol; Park, Sang Hyuk

    2013-12-01

    Cryopreservation preserves periodontal ligament cells but has a lower success rate with dental pulp cells (DPCs) because it causes inflammation. There are 2 well-known cryopreservation methods that reduce inflammation, slow freezing and rapid freezing, but the effects of the 2 methods on inflammation are not well-established. The purpose of this study was to compare the effects of the 2 different cryopreservation methods on CCL-13 induction from DPCs by using microarrays, real-time polymerase chain reaction (PCR), Western blotting, enzyme-linked immunosorbent assay, and confocal laser scanning microscopy (CLSM). In this study, the concentration of cryoprotectant was fixed, and the methods compared differed with respect to freezing speed. Initially we screened the DPCs of cryopreserved teeth with expression microarrays, and CCL-13 was identified as a differentially expressed gene involved in generalized inflammation. We then compared the expression of CCL-13 after exposing teeth to the 2 cryopreservation methods by using real-time PCR, Western blot, enzyme-linked immunosorbent assay, and CLSM. Expression of CCL-13 was up-regulated significantly only in the rapid freezing group, except in measurements made by real-time PCR. CLSM analysis also confirmed this up-regulation visually. Rapid freezing increased the expression of CCL-13 in DPCs compared with slow freezing. Understanding the inflammatory effect of cryopreservation should help to establish an optimal cryoprofile to minimize inflammation of DPCs and reduce the need for endodontic treatment. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Inactivation of Tautomerase Activity of Macrophage Migration Inhibitory Factor by Sulforaphane: A Potential Biomarker for Anti-inflammatory Intervention

    PubMed Central

    Healy, Zachary R.; Liu, Hua; Holtzclaw, W. David; Talalay, Paul

    2011-01-01

    Background Macrophage migration inhibitory factor (MIF), a proinflammatory cytokine with keto-enol tautomerase activity, rises rapidly in response to inflammation, and is elevated in many chronic diseases. Isothiocyanates, such as sulforaphane from broccoli, are very potent inactivators of MIF tautomerase activity. A simple rapid method for determining this activity in tissues and body fluids may therefore be valuable for assessing severity of inflammation and efficacy of intervention. Methods Existing spectrophotometric assays of MIF, based on conversion of methyl L-dopachrome to methyl 5,6-dihydroxyindole-2-carboxylate and associated loss of absorption at 475 nm, lack sensitivity. Assay sensitivity and efficiency were markedly improved by reducing the nonenzymatic rate, by lowering pH to 6.2, replacing phosphate (which catalyzes the reaction) with Bis-Tris buffer, and converting to a microtiter plate format. Results A structure-potency study of MIF tautomerase inactivation by isothiocyanates showed that sulforaphane, benzyl, n-hexyl, and phenethyl isothiocyanates were especially potent. MIF tautomerase could be readily quantified in human urine concentrated by ultrafiltration. This activity comprised: (i) a heat-labile, sulforaphane-inactivated macromolecular fraction (presumably MIF) that was concentrated during ultrafiltration; (ii) a flow-through fraction, with constant activity during filtration, that was heat-stable, and insensitive to sulforaphane. Administration of the sulforaphane precursor glucoraphanin to human volunteers almost completely abolished urinary tautomerase activity, which was recovered over many hours. Conclusions A simple, rapid, quantitative MIF tautomerase assay has been developed as a potential biomarker for assessing inflammatory severity and effectiveness of intervention. Impact An improved assay for measuring MIF tautomerase activity and its applications are described. PMID:21602309

  1. Rapid MRSA PCR on respiratory specimens from ventilated patients with suspected pneumonia: a tool to facilitate antimicrobial stewardship.

    PubMed

    Trevino, S E; Pence, M A; Marschall, J; Kollef, M H; Babcock, H M; Burnham, C-A D

    2017-05-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an important cause of pneumonia in ventilated patients. Our objective was to evaluate the GeneXpert MRSA/SA SSTI Assay (Xpert MRSA/SA) (Cepheid, Sunnyvale, CA) for use in lower respiratory tract (LRT) specimens for rapid MRSA detection and to determine the potentially saved antibiotic-days if a culture-based identification method was replaced by this assay. Remnant LRT samples from ventilated patients submitted to the microbiology laboratory for routine culture were tested using conventional culture and Xpert MRSA/SA. One hundred of 310 LRT specimens met the inclusion criteria. Ten samples were positive for MRSA by Xpert MRSA/SA, while six were positive by routine culture methods. Xpert MRSA/SA correctly identified 5/6 positive and 89/94 negative MRSA specimens, for a sensitivity of 83.3%, specificity of 94.7%, positive predictive value of 45.6%, and negative predictive value of 98.9%. The assay also correctly detected 3/3 positive and 90/97 negative methicillin-susceptible S. aureus (MSSA) specimens, for a sensitivity of 100%, specificity of 92.8%, positive predictive value of 30%, and negative predictive value of 100%. A total of 748 vancomycin and 305 linezolid antibiotic-days were associated with the enrolled specimens. Vancomycin and linezolid utilization could decrease by 68.4% and 83%, respectively, if discontinued 1 day after negative polymerase chain reaction (PCR) results. The Xpert MRSA/SA SSTI rapid MRSA PCR assay performed well in respiratory samples from ventilated patients with suspected pneumonia and has the potential to facilitate stewardship efforts such as reducing empiric vancomycin and linezolid therapy.

  2. Nested PCR Assay for Eight Pathogens: A Rapid Tool for Diagnosis of Bacterial Meningitis.

    PubMed

    Bhagchandani, Sharda P; Kubade, Sushant; Nikhare, Priyanka P; Manke, Sonali; Chandak, Nitin H; Kabra, Dinesh; Baheti, Neeraj N; Agrawal, Vijay S; Sarda, Pankaj; Mahajan, Parikshit; Ganjre, Ashish; Purohit, Hemant J; Singh, Lokendra; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S

    2016-02-01

    Bacterial meningitis is a dreadful infectious disease with a high mortality and morbidity if remained undiagnosed. Traditional diagnostic methods for bacterial meningitis pose a challenge in accurate identification of pathogen, making prognosis difficult. The present study is therefore aimed to design and evaluate a specific and sensitive nested 16S rDNA genus-based polymerase chain reaction (PCR) assay using clinical cerebrospinal fluid (CSF) for rapid diagnosis of eight pathogens causing the disease. The present work was dedicated to development of an in-house genus specific 16S rDNA nested PCR covering pathogens of eight genera responsible for causing bacterial meningitis using newly designed as well as literature based primers for respective genus. A total 150 suspected meningitis CSF obtained from the patients admitted to Central India Institute of Medical Sciences (CIIMS), India during the period from August 2011 to May 2014, were used to evaluate clinical sensitivity and clinical specificity of optimized PCR assays. The analytical sensitivity and specificity of our newly designed genus-specific 16S rDNA PCR were found to be ≥92%. With such a high sensitivity and specificity, our in-house nested PCR was able to give 100% sensitivity in clinically confirmed positive cases and 100% specificity in clinically confirmed negative cases indicating its applicability in clinical diagnosis. Our in-house nested PCR system therefore can diagnose the accurate pathogen causing bacterial meningitis and therefore be useful in selecting a specific treatment line to minimize morbidity. Results are obtained within 24 h and high sensitivity makes this nested PCR assay a rapid and accurate diagnostic tool compared to traditional culture-based methods.

  3. Rapid Identification of Methicillin-Resistant Staphylococcus aureus (MRSA) by the Vitek MS Saramis system.

    PubMed

    Shan, Weiguang; Li, Jiaping; Fang, Ying; Wang, Xuan; Gu, Danxia; Zhang, Rong

    2016-01-01

    A rapid, sensitive, and accurate Vitek MS assay was developed to distinguish clinical isolates of methicillin-resistant Staphylococcus aureus (MRSA) from clinical isolates of methicillin-sensitive Staphylococcus aureus (MSSA) by developing an in-house knowledgebase of SuperSpectra. Three unique peaks, including peaks at 2305.6 and 3007.3 Da specific to MRSA, and 6816.7 Da specific to MSSA, were selected for differentiating MRSA and MSSA. This assay accurately identified 84 and 91% of clinical MRSA and MSSA strains out of the total 142 clinically acquired S. aureus strains that were tested. This method will greatly improve the efficiency of single clinical sample identification of MRSA, thereby facilitating a reduction in the transmission of MRSA in clinical settings.

  4. Methods of rapid diagnosis for the etiology of meningitis in adults

    PubMed Central

    Bahr, Nathan C; Boulware, David R

    2014-01-01

    Infectious meningitis may be due to bacterial, mycobacterial, fungal or viral agents. Diagnosis of meningitis must take into account numerous items of patient history and symptomatology along with regional epidemiology and basic cerebrospinal fluid testing (protein, etc.) to allow the clinician to stratify the likelihood of etiology possibilities and rationally select additional diagnostic tests. Culture is the mainstay for diagnosis in many cases, but technology is evolving to provide more rapid, reliable diagnosis. The cryptococcal antigen lateral flow assay (Immuno-Mycologics) has revolutionized diagnosis of cryptococcosis and automated nucleic acid amplification assays hold promise for improving diagnosis of bacterial and mycobacterial meningitis. This review will focus on a holistic approach to diagnosis of meningitis as well as recent technological advances. PMID:25402579

  5. Reverse transcription recombinase polymerase amplification assay for the rapid detection of type 2 porcine reproductive and respiratory syndrome virus.

    PubMed

    Wang, Jian-Chang; Yuan, Wan-Zhe; Han, Qing-An; Wang, Jin-Feng; Liu, Li-Bing

    2017-05-01

    Porcine reproductive and respiratory syndrome virus (PRRSV) is one of the most important pathogens in pigs, and has tremendous negative economic impact on the swine industry worldwide. PRRSV is classified into the two distinct genotypes: type 1 and type 2, and most of the described PRRSV isolates in China are type 2. Rapid and sensitive detection of PRRSV is of great importance for the disease control and regional eradication programs. Recombinase polymerase amplification (RPA) has emerged as a novel isothermal amplification technology for the molecular diagnosis of infectious diseases. In this study, a fluorescence reverse transcription RPA (RT-RPA) assay was developed to detect the type 2 PRRSV using primers and exo probe specific for the viral nucleocapsid gene. The reaction was performed at 40°C within 20min. The RT-RPA assay could detect both the classical (C-PRRSV) and highly pathogenic PRRSV (HP-PRRSV), but there was no cross-reaction to other pathogens. Using the in vitro transcribed PRRSV RNA as template, the analytical sensitivity of RT-RPA was 690 copies. The assay performance was evaluated by testing 60 field samples and compared to real-time RT-PCR. The detection rate of RT-RPA was 86.6% (52/60), while the detection rate of real-time RT-PCR was 83.3% (50/60). This simple, rapid and reliable method could be potentially applied for rapid detection of PRRSV in point-of-care and rural areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Rapid susceptibility testing of mycobacterium avium complex and mycobacterium tuberculosis isolated from AIDS patients

    NASA Technical Reports Server (NTRS)

    Dhople, Arvind M.

    1993-01-01

    In ominous projections issued by both U.S. Public Health Service and the World Health Organization, the epidemic of the Human Immunodeficiency Virus (HIV) infection will continue to rise more rapidly worldwide than predicted earlier. The Acquired Immunodeficiency Syndrome (AIDS) patients are susceptible to diseases called opportunistic infections of which tuberculosis and M. avium Complex (MAC) infection are most common. This has created an urgent need to uncover new drugs for the treatment of these infections. In the seventies, NASA scientists at Goddard Space Flight Center, Greenbelt, Maryland, had adopted a biochemical indicator, adenosine triphosphate (ATP), to detect presence of life in extraterrestrial space. Therefore, we proposed to develop ATP assay technique to determine sensitivity of antibacterial compounds against MAC and M. tuberculosis. The work was initiated in June 1992. In the last report, we described our efforts in developing ATP assay method using MAC. Studies were continued further, and during the period of this report, we established the relationship between colony forming units and ATP levels of these organisms during the growth cycle. Also, we evaluated the effects of standard antimycobacterial drugs using ATP assay technique and compared the results with those obtained with conventional tube dilution proportional method.

  7. Early Detection of Dengue Virus by Use of Reverse Transcription-Recombinase Polymerase Amplification

    PubMed Central

    Teoh, Boon-Teong; Sam, Sing-Sin; Tan, Kim-Kee; Danlami, Mohammed Bashar; Shu, Meng-Hooi; Johari, Jefree; Hooi, Poh-Sim; Brooks, David; Piepenburg, Olaf; Nentwich, Oliver; Wilder-Smith, Annelies; Franco, Leticia; Tenorio, Antonio

    2015-01-01

    A method for the rapid diagnosis of early dengue virus (DENV) infection is highly needed. Here, a prototype reverse transcription-recombinase polymerase amplification (RT-RPA) assay was developed. The assay detected DENV RNA in <20 min without the need for thermocycling amplification. The assay enabled the detection of as few as 10 copies of DENV RNA. The designed RT-RPA primers and exo probe detected the DENV genome of at least 12 genotypes of DENV circulating globally without cross-reacting with other arboviruses. We assessed the diagnostic performance of the RT-RPA assay for the detection of DENV RNA in 203 serum samples of patients with clinically suspected dengue. The sera were simultaneously tested for DENV using a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay, quantitative RT-PCR (qRT-PCR), and IgM- and IgG-capture enzyme-linked immunosorbent assays (ELISA). Acute DENV infection was confirmed in 130 samples and 61 of the samples (46.9%) were classified as viremic with qRT-PCR. The RT-RPA assay showed good concordance (κ of ≥0.723) with the RT-LAMP and qRT-PCR assays in detecting the dengue viremic samples. When used in combination with ELISA, both the RT-RPA and RT-LAMP assays increased the detection of acute DENV infection to ≥95.7% (≥45/47) in samples obtained within 5 days of illness. The results from the study suggest that the RT-RPA assay is the most rapid molecular diagnostic tool available for the detection of DENV. Hence, it is possible to use the RT-RPA assay in a laboratory to complement routine serology testing for dengue. PMID:25568438

  8. Comparison of Established and Emerging Biodosimetry Assays

    PubMed Central

    Rothkamm, K.; Beinke, C.; Romm, H.; Badie, C.; Balagurunathan, Y.; Barnard, S.; Bernard, N.; Boulay-Greene, H.; Brengues, M.; De Amicis, A.; De Sanctis, S.; Greither, R.; Herodin, F.; Jones, A.; Kabacik, S.; Knie, T.; Kulka, U.; Lista, F.; Martigne, P.; Missel, A.; Moquet, J.; Oestreicher, U.; Peinnequin, A.; Poyot, T.; Roessler, U.; Scherthan, H.; Terbrueggen, B.; Thierens, H.; Valente, M.; Vral, A.; Zenhausern, F.; Meineke, V.; Braselmann, H.; Abend, M.

    2014-01-01

    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3–0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5–4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools. PMID:23862692

  9. PCR-RFLP assays to distinguish the Western and Eastern phylogroups in wild and cultured tench Tinca tinca.

    PubMed

    Lajbner, Z; Kotlík, P

    2011-03-01

    The tench Tinca tinca is a valued table fish native to Europe and Asia, but which is now widely distributed in many temperate freshwater regions of the world as the result of human-mediated translocations. Fish are currently being transplanted between watersheds without concern for genetic similarity to wild populations or local adaptation, and efficient phylogeographic markers are therefore urgently needed to rapidly distinguish genetically distinct geographical populations and to assess their contribution to the hatchery breeds and to the stocked wild populations. Here, we present a new method to distinguish recently discovered and morphologically undistinguishable Western and Eastern phylogroups of the tench. The method relies on PCR-RFLP assays of two independent nuclear-encoded exon-primed intron-crossing (EPIC) markers and of one mitochondrial DNA (mDNA) marker and allows the rapid identification of the Western and Eastern phylogroup and also of three geographical mtDNA clades within the Eastern phylogroup. Our method will enable researchers and fishery practitioners to rapidly distinguish genetically divergent geographical populations of the tench and will be useful for monitoring the introduction and human-mediated spread of the phylogroups in wild populations, for characterization of cultured strains and in breeding experiments. © 2010 Blackwell Publishing Ltd.

  10. Endpoint visual detection of three genetically modified rice events by loop-mediated isothermal amplification.

    PubMed

    Chen, Xiaoyun; Wang, Xiaofu; Jin, Nuo; Zhou, Yu; Huang, Sainan; Miao, Qingmei; Zhu, Qing; Xu, Junfeng

    2012-11-07

    Genetically modified (GM) rice KMD1, TT51-1, and KF6 are three of the most well known transgenic Bt rice lines in China. A rapid and sensitive molecular assay for risk assessment of GM rice is needed. Polymerase chain reaction (PCR), currently the most common method for detecting genetically modified organisms, requires temperature cycling and relatively complex procedures. Here we developed a visual and rapid loop-mediated isothermal amplification (LAMP) method to amplify three GM rice event-specific junction sequences. Target DNA was amplified and visualized by two indicators (SYBR green or hydroxy naphthol blue [HNB]) within 60 min at an isothermal temperature of 63 °C. Different kinds of plants were selected to ensure the specificity of detection and the results of the non-target samples were negative, indicating that the primer sets for the three GM rice varieties had good levels of specificity. The sensitivity of LAMP, with detection limits at low concentration levels (0.01%−0.005% GM), was 10- to 100-fold greater than that of conventional PCR. Additionally, the LAMP assay coupled with an indicator (SYBR green or HNB) facilitated analysis. These findings revealed that the rapid detection method was suitable as a simple field-based test to determine the status of GM crops.

  11. Rapid detection of the neonicotinoid insecticide imidacloprid using a quenchbody assay.

    PubMed

    Zhao, Shitao; Dong, Jinhua; Jeong, Hee-Jin; Okumura, Koichi; Ueda, Hiroshi

    2018-04-28

    Contamination of the land and water by neonicotinoid insecticide residues is currently a severe environmental problem. However, the traditional methods for pesticide residue analysis are time consuming and laborious. To tackle this problem, here we describe a novel quenchbody (Q-body) immunoassay reagent that allows the rapid and sensitive detection of imidacloprid, one of the most frequently used neonicotinoid pesticides, in aqueous solution. A Q-body comprises an antibody Fab fragment that is site-specifically labeled with a fluorescent dye. The Fab fragment quenches the dye with its internal tryptophan residues via photoinduced electron transfer. The subsequent addition of imidacloprid stabilizes the antibody structure and displaces the quenched dye to the outside of the protein, resulting in increased fluorescence. The constructed Q-body assay exhibited a high dynamic range and a low limit of detection (10 ng mL -1 ), and the entire assay procedure could be completed in a few minutes. The assay showed a low cross-reactivity with possible interfering analogous compounds, indicating that it has a good selectivity. Hence, the developed Q-body assay has excellent potential as a universal technology for monitoring neonicotinoid residues in environmental and food samples. Graphical abstract A novel quenchbody (Q-body) immunoassay reagent that allows the rapid and sensitive detection of imidacloprid, one of the most frequently used neonicotinoid pesticides, in aqueous solution was developed. The addition of imidacloprid stabilizes the Q-body structure and displaces the quenched dye to the outside of the protein, resulting in increased fluorescence. The constructed Q-body assay exhibited a high dynamic range and a low limit of detection (10 ng mL -1 ), and completed in a few minutes.

  12. Recent developments in detection and enumeration of waterborne bacteria: a retrospective minireview.

    PubMed

    Deshmukh, Rehan A; Joshi, Kopal; Bhand, Sunil; Roy, Utpal

    2016-12-01

    Waterborne diseases have emerged as global health problems and their rapid and sensitive detection in environmental water samples is of great importance. Bacterial identification and enumeration in water samples is significant as it helps to maintain safe drinking water for public consumption. Culture-based methods are laborious, time-consuming, and yield false-positive results, whereas viable but nonculturable (VBNCs) microorganisms cannot be recovered. Hence, numerous methods have been developed for rapid detection and quantification of waterborne pathogenic bacteria in water. These rapid methods can be classified into nucleic acid-based, immunology-based, and biosensor-based detection methods. This review summarizes the principle and current state of rapid methods for the monitoring and detection of waterborne bacterial pathogens. Rapid methods outlined are polymerase chain reaction (PCR), digital droplet PCR, real-time PCR, multiplex PCR, DNA microarray, Next-generation sequencing (pyrosequencing, Illumina technology and genomics), and fluorescence in situ hybridization that are categorized as nucleic acid-based methods. Enzyme-linked immunosorbent assay (ELISA) and immunofluorescence are classified into immunology-based methods. Optical, electrochemical, and mass-based biosensors are grouped into biosensor-based methods. Overall, these methods are sensitive, specific, time-effective, and important in prevention and diagnosis of waterborne bacterial diseases. © 2016 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  13. Rapid detection of duck hepatitis A virus genotype C using reverse transcription loop-mediated isothermal amplification.

    PubMed

    Li, Chuanfeng; Chen, Zongyan; Meng, Chunchun; Liu, Guangqing

    2014-02-01

    A one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was used and optimized to develop a rapid and sensitive detection system for duck hepatitis A virus genotype C (DHAV-C) RNA. A set of four specific primers was designed against highly conserved sequences located within the 3D gene from DHAV (strain GX1201). Under optimal reaction conditions, the sensitivity of DHAV-C-specific RT-LAMP was 100-fold higher than that of reverse transcriptase-polymerase chain reaction (RT-PCR), with a detection limit of 0.3pg (6.59×10(4) copies) per reaction. No cross-reactivity was observed from the samples of other duck viruses, which is in good accordance with RT-PCR. Furthermore, a positive reaction can be visually inspected by observing turbidity or color change after the addition of SYBR green I dye. The DHAV-C-specific RT-LAMP assay was applied to the samples and compared with RT-PCR. The positive-sample ratios were 26.7% (12 of 45) by RT-LAMP and 20% (9 of 45) by RT-PCR. Therefore, the newly developed RT-LAMP assay is a rapid, specific, sensitive, and cost-effective method of DHAV-C detection. This assay has potential applications in both clinical diagnosis and field surveillance of DHAV-C infection. Copyright © 2013. Published by Elsevier B.V.

  14. Quantitative PCR for genetic markers of human fecal pollution

    EPA Science Inventory

    Assessment of health risk and fecal bacteria loads associated with human fecal pollution requires reliable host-specific analytical methods and a rapid quantification approach. We report the development of quantitative PCR assays for enumeration of two recently described hum...

  15. Compendium of the FY1988 and FY1989 Research Reviews for the Research Methods Branch

    DTIC Science & Technology

    1993-02-01

    14, contained a very aggressive cholangiocarcinoma . DNA from these tissues was examined by primary transfection assay. DNA isolated from the MAM-Ac...exposed animals appeared to correlate with the degree of malignancy observed in the liver. DNA isolated from the cholangiocarcinoma lesion in MD6-14 was...transfection. DNA isolated from the cholangiocarcinoma lesion of MD6-14 very rapidly transformed NIH 3T3 cells as determined by standard focus assay

  16. A Field-expedient Method for Detection of Leptospirosis Causative Agents in Rodents

    DTIC Science & Technology

    2012-01-01

    carboxytetramethylrhodamine (TAMRA)) (Roche Molecular Diagnostics, Pleasanton, California).24,25 Polymerase Chain Reaction. Wet reagent LPS PCR assay...City, Utah). Primers and probe were optimized with R.A.P.I.D. wet reagents and the optimum condition was 5 mmol/L MgCl2, 400 nmol/L primers, 100 nmol...for 20 seconds of combined annealing and primer extension. Linearity and Limit of Detection. The linearity of the LPS freeze-dried assay was

  17. A Rapid Assay to Detect Toxigenic Penicillium spp. Contamination in Wine and Musts

    PubMed Central

    Sanzani, Simona Marianna; Miazzi, Monica Marilena; di Rienzo, Valentina; Fanelli, Valentina; Gambacorta, Giuseppe; Taurino, Maria Rosaria; Montemurro, Cinzia

    2016-01-01

    Wine and fermenting musts are grape products widely consumed worldwide. Since the presence of mycotoxin-producing fungi may greatly compromise their quality characteristics and safety, there is an increasing need for relatively rapid “user friendly” quantitative assays to detect fungal contamination both in grapes delivered to wineries and in final products. Although other fungi are most frequently involved in grape deterioration, secondary infections by Penicillium spp. are quite common, especially in cool areas with high humidity and in wines obtained by partially dried grapes. In this work, a single-tube nested real-time PCR approach—successfully applied to hazelnut and peanut allergen detection—was tested for the first time to trace Penicillium spp. in musts and wines. The method consisted of two sets of primers specifically designed to target the β-tubulin gene, to be simultaneously applied with the aim of lowering the detection limit of conventional real-time PCR. The assay was able to detect up to 1 fg of Penicillium DNA. As confirmation, patulin content of representative samples was determined. Most of analyzed wines/musts returned contaminated results at >50 ppb and a 76% accordance with molecular assay was observed. Although further large-scale trials are needed, these results encourage the use of the newly developed method in the pre-screening of fresh and processed grapes for the presence of Penicillium DNA before the evaluation of related toxins. PMID:27509524

  18. A rapid UPLC-MS/MS assay for eicosanoids in human plasma: Application to evaluate niacin responsivity.

    PubMed

    Miller, Tricia M; Poloyac, Samuel M; Anderson, Kacey B; Waddell, Brooke L; Messamore, Erik; Yao, Jeffrey K

    2017-01-18

    A rapid and sensitive method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed to simultaneously quantify hydroxyeicosatetraenoic (HETE), dihydroxyeicosatrienoic (DiHETrE), epoxyeicosatrienoic acid (EET), and prostaglandin metabolites of arachidonic acid in human plasma. Sample preparation consisted of solid phase extraction with Oasis HLB (30mg) cartridges for all metabolites. Separation of HETEs, EETs, and DiHETrEs was achieved on an Acquity UPLC BEH C18, 1.7µm (100×2.1mm) reversed-phase column (Waters Corp, Millford, MA) with negative electrospray ionization mass spectrometric detection. A second injection of the same extracted sample allowed for separation and assessment of prostaglandin metabolites under optimized UPLC-MS/MS conditions. Additionally, the endogenous levels of these metabolites in five different matrices were determined in order to select the optimal matrix for assay development. Human serum albumin was shown to have the least amount of endogenous metabolites, a recovery efficiency of 79-100% and a matrix effect of 71 - 100%. Linear calibration curves ranging from 0.416 to 66.67ng/ml were validated. Inter-assay and intra-assay variance was less than 15% at most concentrations. This method was successfully applied to quantify metabolite levels in plasma samples of healthy control subjects receiving niacin administration to evaluate the association between niacin administration and eicosanoid plasma level response. Published by Elsevier Ltd.

  19. Gold nanoparticle-based enzyme-linked antibody-aptamer sandwich assay for detection of Salmonella Typhimurium.

    PubMed

    Wu, Wenhe; Li, Jun; Pan, Dun; Li, Jiang; Song, Shiping; Rong, Mingge; Li, Zixi; Gao, Jimin; Lu, Jianxin

    2014-10-08

    Enzyme-linked immunosorbent assay (ELISA) provides a convenient means for the detection of Salmonella enterica serovar Typhimurium (STM), which is important for rapid diagnosis of foodborne pathogens. However, conventional ELISA is limited by antibody-antigen immunoreactions and suffers from poor sensitivity and tedious sample pretreatment. Therefore, development of novel ELISA remains challenging. Herein, we designed a comprehensive strategy for rapid, sensitive, and quantitative detection of STM with high specificity by gold nanoparticle-based enzyme-linked antibody-aptamer sandwich (nano-ELAAS) method. STM was captured and preconcentrated from samples with aptamer-modified magnetic particles, followed by binding with detector antibodies. Then nanoprobes carrying a large amount of reporter antibodies and horseradish peroxidase molecules were used for colorimetric signal amplification. Under the optimized reaction conditions, the nano-ELAAS assay had a quantitative detection range from 1 × 10(3) to 1 × 10(8) CFU mL(-1), a limit of detection of 1 × 10(3) CFU mL(-1), and a selectivity of >10-fold for STM in samples containing other bacteria at higher concentration with an assay time less than 3 h. In addition, the developed nanoprobes were improved in terms of detection range and/or sensitivity when compared with two commercial enzyme-labeled antibody signal reporters. Finally, the nano-ELAAS method was demonstrated to work well in milk samples, a common source of STM contamination.

  20. A Rapid Assay to Detect Toxigenic Penicillium spp. Contamination in Wine and Musts.

    PubMed

    Sanzani, Simona Marianna; Miazzi, Monica Marilena; di Rienzo, Valentina; Fanelli, Valentina; Gambacorta, Giuseppe; Taurino, Maria Rosaria; Montemurro, Cinzia

    2016-08-08

    Wine and fermenting musts are grape products widely consumed worldwide. Since the presence of mycotoxin-producing fungi may greatly compromise their quality characteristics and safety, there is an increasing need for relatively rapid "user friendly" quantitative assays to detect fungal contamination both in grapes delivered to wineries and in final products. Although other fungi are most frequently involved in grape deterioration, secondary infections by Penicillium spp. are quite common, especially in cool areas with high humidity and in wines obtained by partially dried grapes. In this work, a single-tube nested real-time PCR approach-successfully applied to hazelnut and peanut allergen detection-was tested for the first time to trace Penicillium spp. in musts and wines. The method consisted of two sets of primers specifically designed to target the β-tubulin gene, to be simultaneously applied with the aim of lowering the detection limit of conventional real-time PCR. The assay was able to detect up to 1 fg of Penicillium DNA. As confirmation, patulin content of representative samples was determined. Most of analyzed wines/musts returned contaminated results at >50 ppb and a 76% accordance with molecular assay was observed. Although further large-scale trials are needed, these results encourage the use of the newly developed method in the pre-screening of fresh and processed grapes for the presence of Penicillium DNA before the evaluation of related toxins.

  1. Simultaneous assay for plasmin and DNase using radiolabeled human fibroblasts on microcarriers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boswell, G.S.; Dimitrijevich, S.D.; Gracy, R.W.

    1989-10-01

    A critical step in tissue and wound repair is the removal of eschar--accumulation of denatured cellular and extracellular macromolecules. Enzymatic debridement using a combination of plasmin (fibrinolysin) and DNase has been successfully utilized on a variety of types of wounds. Monitoring the activity of these enzymes by measuring the rate of fibrinolysis, or by viscometric changes due to DNA hydrolysis, is exceedingly cumbersome, time consuming, and, at best, only semiquantitative. Although spectrophotometric assays using synthetic substrates offer several advantages, they do not allow extrapolation of the data to the more complex natural substrates encountered in vivo. We have, therefore, developedmore » an in vitro radioisotopic assay for the simultaneous and quantitative measurement of the hydrolytic activity of both plasmin and DNase. Double labeled ((3H)thymidine, (14C)leucine) human dermal fibroblasts grown on microcarrier beads are utilized as sources of nucleic acid and protein substrates. The assay meets all the criteria of analytical validity, is sensitive and rapid, and is amenable to adaptation for analysis of other hydrolytic enzymes. The method offers a direct evaluation of the enzymatic debridement of wounds using actual human cellular substrates. Moreover, the microcarriers provide a greatly increased surface area for cell attachment and growth, are amenable to rapid separation from the cells by simple mechanical methods, and are ideally suited to analytical manipulations.« less

  2. Development, optimization and validation of a rapid colorimetric microplate bioassay for neomycin sulfate in pharmaceutical drug products.

    PubMed

    Francisco, Fabiane Lacerda; Saviano, Alessandro Morais; Pinto, Terezinha de Jesus Andreoli; Lourenço, Felipe Rebello

    2014-08-01

    Microbiological assays have been used to evaluate antimicrobial activity since the discovery of the first antibiotics. Despite their limitations, microbiological assays are widely employed to determine antibiotic potency of pharmaceutical dosage forms, since they provide a measure of biological activity. The aim of this work is to develop, optimize and validate a rapid colorimetric microplate bioassay for the potency of neomycin in pharmaceutical drug products. Factorial and response surface methodologies were used in the development and optimization of the choice of microorganism, culture medium composition, amount of inoculum, triphenyltetrazolium chloride (TTC) concentration and neomycin concentration. The optimized bioassay method was validated by the assessment of linearity (range 3.0 to 5.0μg/mL, r=0.998 and 0.994 for standard and sample curves, respectively), precision (relative standard deviation (RSD) of 2.8% and 4.0 for repeatability and intermediate precision, respectively), accuracy (mean recovery=100.2%) and robustness. Statistical analysis showed equivalency between agar diffusion microbiological assay and rapid colorimetric microplate bioassay. In addition, microplate bioassay had advantages concerning the sensitivity of response, time of incubation, and amount of culture medium and solutions required. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Ultrasensitive and rapid detection of β-conglutin combining aptamers and isothermal recombinase polymerase amplification.

    PubMed

    Jauset-Rubio, Miriam; Sabaté Del Río, Jonathan; Mairal, Teresa; Svobodová, Markéta; El-Shahawi, Mohammad S; Bashammakh, Abdulaziz S; Alyoubi, Abdulrahman O; O'Sullivan, Ciara K

    2017-01-01

    Lupin is increasingly being used in a variety of food products due to its nutritional, functional and nutraceutical properties. However, several examples of severe and even fatal food-associated anaphylaxis due to lupin inhalation or ingestion have been reported, resulting in the lupin subunit β-conglutin, being defined as the Lup an 1 allergen by the International Union of Immunological Societies (IUIS) in 2008. Here, we report an innovative method termed aptamer-recombinase polymerase amplification (Apta-RPA) exploiting the affinity and specificity of a DNA aptamer selected against the anaphylactic β-conglutin allergen termed β-conglutin binding aptamer II (β-CBA II), facilitating ultrasensitive detection via isothermal amplification. Combining magnetic beads as the solid phase with Apta-RPA detection, the total assay time was reduced from 210 min to just 25 min, with a limit of detection of 3.5 × 10 -11  M, demonstrating a rapid and ultrasensitive generic methodology that can be used with any aptamer. Future work will focus on further simplification of the assay to a lateral flow format. Graphical Abstract Schematic representation of the rapid and novel bead-based Apta-RPA assay.

  4. Development of a rapid recombinase polymerase amplification assay for the detection of Streptococcus pneumoniae in whole blood.

    PubMed

    Clancy, Eoin; Higgins, Owen; Forrest, Matthew S; Boo, Teck Wee; Cormican, Martin; Barry, Thomas; Piepenburg, Olaf; Smith, Terry J

    2015-10-29

    Streptococcus pneumoniae is an important cause of microbial disease in humans. The introduction of multivalent vaccines has coincided with a dramatic decrease in the number of pneumococcal-related deaths. In spite of this, at a global level, pneumococcal infection remains an important cause of death among children under 5 years of age and in adults 65 years of age or older. In order to properly manage patients and control the spread of infection, a rapid and highly sensitive diagnostic method is needed for routine implementation, especially in resource-limited regions where pneumococcal disease is most prevalent. Using the gene encoding leader peptidase A as a molecular diagnostics target, a real-time RPA assay was designed and optimised for the detection of S. pneumoniae in whole blood. The performance of the assay was compared to real-time PCR in terms of its analytical limit of detection and specificity. The inhibitory effect of human genomic DNA on amplification was investigated. The potential clinical utility of the assay was investigated using a small number of clinical samples. The RPA assay has a limit of detection equivalent to PCR (4.0 and 5.1 genome equivalents per reaction, respectively) and was capable of detecting the equivalent of <1 colony forming unit of S. pneumoniae when spiked into human whole blood. The RPA assay was 100 % inclusive (38/38 laboratory reference strains and 19/19 invasive clinical isolates) and 100 % exclusive; differentiating strains of S. pneumoniae species from other viridans group streptococci, including S. pseudopneumoniae. When applied to the analysis of a small number (n = 11) of clinical samples (blood culture positive for S. pneumoniae), the RPA assay was demonstrated to be both rapid and sensitive. The RPA assay developed in this work is shown to be as sensitive and as specific as PCR. In terms of reaction kinetics, the RPA assay is shown to exceed those of the PCR, with the RPA running to completion in 20 minutes and capable generating a positive signal in as little as 6 minutes. This work represents a potentially suitable assay for application in point-of-care settings.

  5. Rapid diagnosis of sensitivity to ultraviolet light in fibroblasts from dermatologic disorders, with particular reference to xeroderma pigmentosum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cleaver, J.E.; Thomas, G.H.

    1988-04-01

    A rapid and simple method for determining the sensitivity of human fibroblasts to ultraviolet light is described. As an alternative to the colony formation assay, this method can be used for the rapid diagnosis of ultraviolet light sensitivity in fibroblasts from photosensitive disorders. The method is based on growth of small numbers of cells in 1-cm wells of culture trays for 4 or more days after irradiation and determination of cell survival by the incorporation of (/sup 3/H)hypoxanthine. D37 values (the dose at which 37% of the control level of incorporation remains) obtained from this procedure showed the same relativemore » sensitivity of normal and xeroderma pigmentosum fibroblasts as was obtained by colony formation. Untransformed and SV40-transformed fibroblasts, which have different growth rates and different responses to high cell densities, gave different D37 values by this assay in culture trays as compared with colony formation. Comparison of relative sensitivities to irradiation should therefore be made only between cell types with similar growth characteristics. The similar sensitivity of normal and xeroderma pigmentosum cells to mitomycin C was also determined by this culture tray method. By increasing cell density at the beginning of the experiments, a greater capacity of group C compared with group D fibroblasts for recovery from potentially lethal damage was also detected.« less

  6. Rapid diagnosis of Theileria annulata by recombinase polymerase amplification combined with a lateral flow strip (LF-RPA) in epidemic regions.

    PubMed

    Yin, Fangyuan; Liu, Junlong; Liu, Aihong; Li, Youquan; Luo, Jianxun; Guan, Guiquan; Yin, Hong

    2017-04-15

    Rapid and accurate diagnosis of Theileria annulata infection contributes to the formulation of strategies to eradicate this parasite. A simple and efficient diagnostic tool, recombinase polymerase amplification (RPA) combined with a lateral flow (LF) strip, was used in detection of Theileria and compared to other methods that require expensive instruments and skilled personnel. Herein, we established and optimized an LF-RPA method to detect the cytochrome b gene of T. annulata mitochondrial DNA from experimentally infected and field-collected blood samples. This method has many unparalleled characteristics, including that it is rapid (clear detection in 5min at constant temperature), sensitive (the limitation of detection is at least 2pg genomic DNA), and specific (no cross-reaction with other piroplasms that infect cattle). The LF-RPA assay was evaluated via testing 17 field blood samples and comparing the results of that of a PCR, showing 100% agreement, which demonstrates the ability of the LF-RPA assay to detect T. annulata infections in small number of samples (n=17). Taken together, the results indicate that this method could be used as an ideal diagnostic tool for detecting T. annulata in endemic regions with limited to fewer and local resources and could also be a potential technique for the surveillance and control of blood protozoa. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. groEL is a suitable genetic marker for detecting Vibrio parahaemolyticus by loop-mediated isothermal amplification assay.

    PubMed

    Siddique, M P; Jang, W J; Lee, J M; Ahn, S H; Suraiya, S; Kim, C H; Kong, I S

    2017-08-01

    A groEL gene-based loop-mediated isothermal amplification (LAMP) assay was developed to detect Vibrio parahaemolyticus in contaminated seafood and water. The assay was optimized and conducted at 63°C for 40 min using Bacillus stearothermophilus (Bst) DNA polymerase, large fragment. Amplification was analysed via multiple detection methods, including opacity, formation of white precipitate, DNA intercalating dyes (ethidium bromide and SYBR Green I), metal ion-binding indicator dye, calcein, and 2% agarose gel electrophoresis. A characteristic ladder-like band pattern on agarose gel and the desired colour changes when using different dyes were observed in positive cases, and these were species-specific for V. parahaemolyticus when compared with other closely related Vibrio spp. The limit of detection (LoD) of this assay was 100 fg per reaction, 100-fold higher than that for conventional polymerase chain reaction (PCR). When tested on artificially contaminated seafood and seawater, the LoDs of the LAMP assay were 120 and 150 fg per reaction respectively, and those of conventional PCR were 120 and 150 pg per reaction respectively. Based on our results, the groEL gene-based LAMP assay is rapid, specific, sensitive, and reliable for detecting V. parahaemolyticus, and it could be used in field diagnosis. The loop-mediated isothermal amplification (LAMP) assay using groEL gene (an abundant, highly conserved gene and member of the groESL chaperone gene family) provided rapid, species-specific and highly sensitive method for detecting Vibrio parahaemolyticus, the leading causal agent of seafood-borne diseases worldwide. Moreover, groEL LAMP revealed high efficiency than conventional PCR assay for V. parahaemolyticus using template both from pure culture and artificially contaminated seafood and water, which indicated the applicability in the field and environmental screening purpose for the organism. © 2017 The Society for Applied Microbiology.

  8. Validation of a new point-of-care assay for determination of β-carotene concentration in bovine whole blood and plasma.

    PubMed

    Raila, Jens; Enjalbert, Francis; Mothes, Ralf; Hurtienne, Andrea; Schweigert, Florian J

    2012-03-01

    β-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. β-Carotene concentrations in plasma are used to optimize β-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure β-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring β-carotene in whole blood and plasma. β-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Concentrations of β-carotene in plasma measured using the POC assay ranged from 0.40 to 15.84 mg/L (n = 166). No differences were observed between methods for assay of plasma (mean ± SD; n = 166): HPLC-plasma 4.23 ± 2.35 mg/L; POC-plasma 4.49 ± 2.36 mg/L. Similar good agreement was found when plasma analyzed using HPLC was compared with whole blood analyzed using the POC system (n = 23): HPLC-plasma 3.46 ± 2.12 mg/L; POC-whole blood 3.67 ± 2.29 mg/L. Concentrations of β-carotene can be measured in blood and plasma from cattle easily and rapidly using a POC assay, and results are comparable to those obtained by the highly sophisticated HPLC method. Immediate feedback regarding β-carotene deficiency facilitates rapid and appropriate optimization of β-carotene supplementation in feed. © 2012 American Society for Veterinary Clinical Pathology.

  9. Development of a rapid recombinase polymerase amplification assay for detection of Brucella in blood samples.

    PubMed

    Ren, Hang; Yang, Mingjuan; Zhang, Guoxia; Liu, Shiwei; Wang, Xinhui; Ke, Yuehua; Du, Xinying; Wang, Zhoujia; Huang, Liuyu; Liu, Chao; Chen, Zeliang

    2016-04-01

    A rapid and sensitive recombinase polymerase amplification (RPA) assay, Bruce-RPA, was developed for detection of Brucella. The assay could detect as few as 3 copies of Brucella per reaction within 20 min. Bruce-RPA represents a candidate point-of-care diagnosis assay for human brucellosis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... microagglutination test, the enzyme-linked immunosorbent assay test (ELISA), or the rapid serum test for all poultry... react on rapid serum test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that... inhibition (HI) test, the microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA...

  11. Development and evaluation of an up-converting phosphor technology-based lateral flow assay for the rapid, simultaneous detection of Vibrio cholerae serogroups O1 and O139

    PubMed Central

    Li, Baisheng; Liu, Xiao; Zhao, Yong; Tan, Hailing; Sun, Chongyun; Wang, Xiaochen; Wang, Xinrui; Qiu, Haiyan; Wang, Duochun; Diao, Baowei; Jing, Huaiqi; Yang, Ruifu; Kan, Biao

    2017-01-01

    Vibrio cholerae serogroups O1 and O139 are etiological agents of cholera, a serious and acute diarrheal disease, and rapid detection of V. cholerae is a key method for preventing and controlling cholera epidemics. Here, a point of care testing (POCT) method called Vch-UPT-LF, which is an up-converting phosphor technology-based lateral flow (UPT-LF) assay with a dual-target detection mode, was developed to detect V. cholerae O1 and O139 simultaneously from one sample loading. Although applying an independent reaction pair made both detection results for the two Vch-UPT-LF detection channels more stable, the sensitivity slightly declined from 104 to 105 colony-forming units (CFU) mL−1 compared with that of the single-target assay, while the quantification ranges covering four orders of magnitude were maintained. The strip showed excellent specificity for seven Vibrio species that are highly related genetically, and nine food-borne species whose transmission routes are similar to those of V. cholerae. The legitimate arrangement of the two adjacent test lines lessened the mutual impact of the quantitation results between the two targets, and the quantification values did not differ by more than one order of magnitude when the samples contained high concentrations of both V. cholerae O1 and O139. Under pre-incubation conditions, 1×101 CFU mL−1 of V. cholerae O1 or O139 could be detected in fewer than 7 h, while the Vch-UPT-LF assay exhibited sensitivity as high as a real-time fluorescent polymerase chain reaction with fewer false-positive results. Therefore, successful development of Vch-UPT-LF as a dual-target assay for quantitative detection makes this assay a good candidate POCT method for the detection and surveillance of epidemic cholera. PMID:28662147

  12. A Quadruplex Real-Time PCR Assay for the Rapid Detection and Differentiation of the Most Relevant Members of the B. pseudomallei Complex: B. mallei, B. pseudomallei, and B. thailandensis

    PubMed Central

    Lowe, Chinn-Woan; Thiriot, Joseph D.; Heder, Michael J.; March, Jordon K.; Drake, David S.; Lew, Cynthia S.; Bunnell, Annette J.; Moore, Emily S.; O'Neill, Kim L.; Robison, Richard A.

    2016-01-01

    The Burkholderia pseudomallei complex classically consisted of B. mallei, B. pseudomallei, and B. thailandensis, but has now expanded to include B. oklahomensis, B. humptydooensis, and three unassigned Burkholderia clades. Methods for detecting and differentiating the B. pseudomallei complex has been the topic of recent research due to phenotypic and genotypic similarities of these species. B. mallei and B. pseudomallei are recognized as CDC Tier 1 select agents, and are the causative agents of glanders and melioidosis, respectively. Although B. thailandensis and B. oklahomensis are generally avirulent, both display similar phenotypic characteristics to that of B. pseudomallei. B. humptydooensis and the Burkholderia clades are genetically similar to the B. pseudomallei complex, and are not associated with disease. Optimal identification of these species remains problematic, and PCR-based methods can resolve issues with B. pseudomallei complex detection and differentiation. Currently, no PCR assay is available that detects the major species of the B. pseudomallei complex. A real-time PCR assay in a multiplex single-tube format was developed to simultaneously detect and differentiate B. mallei, B. pseudomallei, and B. thailandensis, and a common sequence found in B. pseudomallei, B. mallei, B. thailandensis, and B. oklahomensis. A total of 309 Burkholderia isolates and 5 other bacterial species were evaluated. The assay was 100% sensitive and specific, demonstrated sensitivity beyond culture and GC methods for the isolates tested, and is completed in about an hour with a detection limit between 2.6pg and 48.9pg of gDNA. Bioinformatic analyses also showed the assay is likely 100% specific and sensitive for all 84 fully sequenced B. pseudomallei, B. mallei, B. thailandensis, and B. oklahomensis strains currently available in GenBank. For these reasons, this assay could be a rapid and sensitive tool in the detection and differentiation for those species of the B. pseudomallei complex with recognized clinical and practical significance. PMID:27736903

  13. A Quadruplex Real-Time PCR Assay for the Rapid Detection and Differentiation of the Most Relevant Members of the B. pseudomallei Complex: B. mallei, B. pseudomallei, and B. thailandensis.

    PubMed

    Lowe, Chinn-Woan; Satterfield, Benjamin A; Nelson, Daniel B; Thiriot, Joseph D; Heder, Michael J; March, Jordon K; Drake, David S; Lew, Cynthia S; Bunnell, Annette J; Moore, Emily S; O'Neill, Kim L; Robison, Richard A

    2016-01-01

    The Burkholderia pseudomallei complex classically consisted of B. mallei, B. pseudomallei, and B. thailandensis, but has now expanded to include B. oklahomensis, B. humptydooensis, and three unassigned Burkholderia clades. Methods for detecting and differentiating the B. pseudomallei complex has been the topic of recent research due to phenotypic and genotypic similarities of these species. B. mallei and B. pseudomallei are recognized as CDC Tier 1 select agents, and are the causative agents of glanders and melioidosis, respectively. Although B. thailandensis and B. oklahomensis are generally avirulent, both display similar phenotypic characteristics to that of B. pseudomallei. B. humptydooensis and the Burkholderia clades are genetically similar to the B. pseudomallei complex, and are not associated with disease. Optimal identification of these species remains problematic, and PCR-based methods can resolve issues with B. pseudomallei complex detection and differentiation. Currently, no PCR assay is available that detects the major species of the B. pseudomallei complex. A real-time PCR assay in a multiplex single-tube format was developed to simultaneously detect and differentiate B. mallei, B. pseudomallei, and B. thailandensis, and a common sequence found in B. pseudomallei, B. mallei, B. thailandensis, and B. oklahomensis. A total of 309 Burkholderia isolates and 5 other bacterial species were evaluated. The assay was 100% sensitive and specific, demonstrated sensitivity beyond culture and GC methods for the isolates tested, and is completed in about an hour with a detection limit between 2.6pg and 48.9pg of gDNA. Bioinformatic analyses also showed the assay is likely 100% specific and sensitive for all 84 fully sequenced B. pseudomallei, B. mallei, B. thailandensis, and B. oklahomensis strains currently available in GenBank. For these reasons, this assay could be a rapid and sensitive tool in the detection and differentiation for those species of the B. pseudomallei complex with recognized clinical and practical significance.

  14. Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots

    PubMed Central

    2010-01-01

    Background Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. Methods A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Results Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. Conclusions The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration. PMID:20684792

  15. Development of a simple gel permeation clean-up procedure coupled to a rapid disequilibrium enzyme-linked immunosorbent assay (ELISA) for the detection of Sudan I dye in spices and sauces.

    PubMed

    Oplatowska, Michalina; Stevenson, Paul J; Schulz, Claudia; Hartig, Lutz; Elliott, Christopher T

    2011-09-01

    Sudan dyes have been found to be added to chilli and chilli products for illegal colour enhancement purposes. Due to the possible carcinogenic effect, they are not authorized to be used in food in the European Union or the USA. However, over the last few years, many products imported from Asian and African countries have been reported via the Rapid Alert System for Food and Feed in the European Union to be contaminated with these dyes. In order to provide fast screening method for the detection of Sudan I (SI), which is the most widely abused member of Sudan dyes family, a unique (20 min without sample preparation) direct disequilibrium enzyme-linked immunosorbent assay (ELISA) was developed. The assay was based on polyclonal antibodies highly specific to SI. A novel, simple gel permeation chromatography clean-up method was developed to purify extracts from matrices containing high amounts of fat and natural pigments, without the need for a large dilution of the sample. The assay was validated according to the Commission Decision 2002/657/EC criteria. The detection capability was determined to be 15 ng g(-1) in sauces and 50 ng g(-1) in spices. The recoveries found ranged from 81% to 116% and inter- and intra-assay coefficients of variation from 6% to 20%. The assay was used to screen a range of products (85 samples) collected from different retail sources within and outside the European Union. Three samples were found to contain high amounts (1,649, 722 and 1,461 ng g(-1)) of SI by ELISA. These results were confirmed by liquid chromatography-tandem mass spectrometry method. The innovative procedure allows for the fast, sensitive and high throughput screening of different foodstuffs for the presence of the illegal colorant SI.

  16. Targeted Quantitation of Proteins by Mass Spectrometry

    PubMed Central

    2013-01-01

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement. PMID:23517332

  17. Targeted quantitation of proteins by mass spectrometry.

    PubMed

    Liebler, Daniel C; Zimmerman, Lisa J

    2013-06-04

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement.

  18. Identification of gamma-irradiated papaya, melon and watermelon

    NASA Astrophysics Data System (ADS)

    Marín-Huachaca, Nélida S.; Mancini-Filho, Jorge; Delincée, Henry; Villavicencio, Anna Lúcia C. H.

    2004-09-01

    Ionizing radiation can be used to control spoilage microorganisms and to increase the shelf life of fresh fruits and vegetables in replacement for the treatment with chemical fumigants. In order to enforce labelling regulations, methods for detecting the irradiation treatment directly in the produce are required. Recently, a number of detection methods for irradiated food have been adopted by the Codex Comission. A rapid screening method for qualitative detection of irradiation is the DNA Comet Assay. The applicability of the DNA Comet Assay for distinguishing irradiated papaya, melon, and watermelon was evaluated. The samples were treated in a 60Co facility at dose levels of 0.0, 0.5, 0.75, and 1.0kGy. The irradiated samples showed typical DNA fragmentation whereas cells from non-irradiated ones appeared intact. In addition to the DNA Comet Assay also the half-embryo test was applied in melon and watermelon to detect the irradiation treatment.

  19. Validated HPLC Determination of 4-Dimethylaminoantipyrine in Different Suppository Bases

    PubMed Central

    Kalmár, É; Kormányos, B.; Szakonyi, G.; Dombi, G.

    2014-01-01

    Suppositories are important tools for individual therapy, especially in paediatrics, and an instrumental assay method has become necessary for the quality control of dosage units. The aim of this work was to develop a rapid, effective high-performance liquid chromatography method to assay aminophenazone in extemporaneous suppositories prepared with two different suppository bases, adeps solidus and massa macrogoli. With a novel sample preparation method developed by the authors, 4-dimethylaminoantipyrine was determined in these suppository bases with 95-105% recovery. The measurements were carried out on a Shimadzu Prominence ultra high-performance liquid chromatography system equipped with a 20 μl sample loop. The separation was achieved on a Hypersil ODS column, with methanol, sodium acetate buffer (pH 5.5±0.05, 0.05 M, 60:40, v/v) as the mobile phase at a flow rate of 1.5 ml/min. The chromatograms were acquired at 253 nm. The chromatographic method was fully validated in accordance with current guidelines. The presented data demonstrate the successful development of a rapid, efficient and robust sample preparation and high-performance liquid chromatography method for the routine quality control of the dosage units of suppositories containing 4-dimethylaminoantipyrine. PMID:24799736

  20. Locked Nucleic Acid Probe-Based Real-Time PCR Assay for the Rapid Detection of Rifampin-Resistant Mycobacterium tuberculosis

    PubMed Central

    Sun, Chongyun; Li, Chao; Wang, Xiaochen; Liu, Haican; Zhang, Pingping; Zhao, Xiuqin; Wang, Xinrui; Jiang, Yi; Yang, Ruifu; Wan, Kanglin; Zhou, Lei

    2015-01-01

    Drug-resistant Mycobacterium tuberculosis can be rapidly diagnosed through nucleic acid amplification techniques by analyzing the variations in the associated gene sequences. In the present study, a locked nucleic acid (LNA) probe-based real-time PCR assay was developed to identify the mutations in the rpoB gene associated with rifampin (RFP) resistance in M. tuberculosis. Six LNA probes with the discrimination capability of one-base mismatch were designed to monitor the 23 most frequent rpoB mutations. The target mutations were identified using the probes in a “probe dropout” manner (quantification cycle = 0); thus, the proposed technique exhibited superiority in mutation detection. The LNA probe-based real-time PCR assay was developed in a two-tube format with three LNA probes and one internal amplification control probe in each tube. The assay showed excellent specificity to M. tuberculosis with or without RFP resistance by evaluating 12 strains of common non-tuberculosis mycobacteria. The limit of detection of M. tuberculosis was 10 genomic equivalents (GE)/reaction by further introducing a nested PCR method. In a blind validation of 154 clinical mycobacterium isolates, 142/142 (100%) were correctly detected through the assay. Of these isolates, 88/88 (100%) were determined as RFP susceptible and 52/54 (96.3%) were characterized as RFP resistant. Two unrecognized RFP-resistant strains were sequenced and were found to contain mutations outside the range of the 23 mutation targets. In conclusion, this study established a sensitive, accurate, and low-cost LNA probe-based assay suitable for a four-multiplexing real-time PCR instrument. The proposed method can be used to diagnose RFP-resistant tuberculosis in clinical laboratories. PMID:26599667

  1. Most probable number - loop mediated isothermal amplification (MPN-LAMP) for quantifying waterborne pathogens in <25min.

    PubMed

    Ahmad, Farhan; Stedtfeld, Robert D; Waseem, Hassan; Williams, Maggie R; Cupples, Alison M; Tiedje, James M; Hashsham, Syed A

    2017-01-01

    We are reporting a most probable number approach integrated to loop mediated isothermal technique (MPN-LAMP) focusing on Gram-negative Escherichia coli and Gram-positive Enterococcus faecalis bacterial cells without nucleic acids extraction. LAMP assays for uidA from E. coli and gelE from E. faecalis were successfully performed directly on cells up to single digit concentration using a commercial real time PCR instrument. Threshold time values of LAMP assays of bacterial cells, heat treated bacterial cells (95°C for 5min), and their purified genomic DNA templates were similar, implying that amplification could be achieved directly from bacterial cells at 63°C. Viability of bacterial cells was confirmed by using propidium monoazide in a LAMP assay with E. faecalis. To check its functionality on a microfluidic platform, MPN-LAMP assays targeting <10CFU of bacteria were also translated onto polymeric microchips and monitored by a low-cost fluorescence imaging system. The overall system provided signal-to-noise (SNR) ratios up to 800, analytical sensitivity of <10CFU, and time to positivity of about 20min. MPN-LAMP assays were performed for cell concentrations in the range of 10 5 CFU to <10CFU. MPN values from LAMP assays confirmed that the amplifications were from <10CFU. The method described here, applicable directly on cells at 63°C, eliminates the requirement of complex nucleic acids extraction steps, facilitating the development of sensitive, rapid, low-cost, and field-deployable systems. This rapid MPN-LAMP approach has the potential to replace conventional MPN method for waterborne pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Field Demonstration of a Multiplexed Point-of-Care Diagnostic Platform for Plant Pathogens.

    PubMed

    Lau, Han Yih; Wang, Yuling; Wee, Eugene J H; Botella, Jose R; Trau, Matt

    2016-08-16

    Effective disease management strategies to prevent catastrophic crop losses require rapid, sensitive, and multiplexed detection methods for timely decision making. To address this need, a rapid, highly specific and sensitive point-of-care method for multiplex detection of plant pathogens was developed by taking advantage of surface-enhanced Raman scattering (SERS) labeled nanotags and recombinase polymerase amplification (RPA), which is a rapid isothermal amplification method with high specificity. In this study, three agriculturally important plant pathogens (Botrytis cinerea, Pseudomonas syringae, and Fusarium oxysporum) were used to demonstrate potential translation into the field. The RPA-SERS method was faster, more sensitive than polymerase chain reaction, and could detect as little as 2 copies of B. cinerea DNA. Furthermore, multiplex detection of the three pathogens was demonstrated for complex systems such as the Arabidopsis thaliana plant and commercial tomato crops. To demonstrate the potential for on-site field applications, a rapid single-tube RPA/SERS assay was further developed and successfully performed for a specific target outside of a laboratory setting.

  3. The use of real-time polymerase chain reaction for rapid diagnosis of skeletal tuberculosis.

    PubMed

    Kobayashi, Naomi; Fraser, Thomas G; Bauer, Thomas W; Joyce, Michael J; Hall, Gerri S; Tuohy, Marion J; Procop, Gary W

    2006-07-01

    We identified Mycobacterium tuberculosis DNA using real-time polymerase chain reaction on a specimen from an osteolytic lesion of a femoral condyle, in which the frozen section demonstrated granulomas. The process was much more rapid than is possible with culture. The rapid detection of M tuberculosis and the concomitant exclusion of granulomatous disease caused by nontuberculous mycobacteria or systemic fungi are necessary to appropriately treat skeletal tuberculosis. The detection and identification of M tuberculosis by culture may require several weeks using traditional methods. The real-time polymerase chain reaction method used has been shown to be rapid and reliable, and is able to detect and differentiate both tuberculous and nontuberculous mycobacteria. Real-time polymerase chain reaction may become a diagnostic standard for the evaluation of clinical specimens for the presence of mycobacteria; this case demonstrates the potential utility of this assay for the rapid diagnosis of skeletal tuberculosis.

  4. Development of a nanogold slot blot inhibition assay for the detection of antibodies against bovine herpesvirus type 1.

    PubMed

    Japolla, Greice; Cunha-Junior, Jair Pereira; Pajuaba, Ana Claudia Arantes Marquez; Taketomi, Ernesto Akio; Bührer-Sékula, Samira; Bataus, Luiz Artur Mendes; de Souza, Guilherme Rocha Lino

    2018-06-01

    Bovine herpesvirus type 1 (BoHV-1) is recognized as an important pathogen causing respiratory, reproductive, and neurological disorders in cattle and is associated with economic losses to animal industry. Accurate diagnostic methods are needed for prevention of disease transmission. While the virus neutralization test is considered the gold standard method, it requires maintenance of the virus and cell cultures, which is time consuming and expensive. Serological techniques such as enzyme-linked immunosorbent assay (ELISA) are widely applied, as these are easy to perform and provide quick results. In the present study, a nanogold slot blot inhibition assay was developed for the serological diagnosis of BoHV-1 and compared with standard ELISA and horseradish peroxidase (HRP) slot blot assays. Of 42 serum samples tested by ELISA, 32 (76.2%) were positive and 10 (23.8%), were negative. The sensitivity and specificity of the nanogold slot blot inhibition assay was similar to that observed for ELISA and HRP slot blot assays, and a strong correlation was observed between the tests. Thus, the nanogold slot blot inhibition assay may serve as an efficient and rapid alternative to ELISA in settings, where plate-reading equipment is lacking.

  5. Rapid genetic typing of diarrheagenic Escherichia coli using a two-tube modified molecular beacon based multiplex real-time PCR assay and its clinical application

    PubMed Central

    2014-01-01

    Background Diarrheagenic Escherichia coli (DEC), including Enterotoxigenic E.coli (ETEC), Enteroaggregative E.coli (EAEC), Enteropathogenic E.coli (EPEC), Enterohemolysin E.coli (EHEC) and Enteroinvasive E.coli (EIEC) causes diarrhea or hemolytic uremic syndromes among infants and travelers around the world. A rapid, reliable and repeatable method is urgent for identifying DEC so as to provide the reference for responding to diarrheal disease outbreak and the treatment of the diarrheal patients associated with DEC. Methods In this study, specific primers and modified molecular beacon probes of nine specific virulence genes, whose 5′end were added with homo tail sequence, were designed; and a two-tube modified molecular beacon based multiplex real–time PCR (rtPCR) assay for the identification of five Escherichia coli pathotypes, including ETEC, EAEC, EPEC, EHEC and EIEC was developed and optimized. Totally 102 bacterial strains, including 52 reference bacterial strains and 50 clinical strains were detected to confirm whether the target genes selected were specific. Then detection limits of the assay were tested. Lastly, the assay was applied to the detection of 11860 clinical samples to evaluate the specificity and sensitivity of the developed assay compared with the conventional PCR. Results The target genes were 100% specific as assessed on 102 bacterial strains since no cross-reactions were observed. The detection limits ranged from 88 CFU/mL (EHEC) to 880 CFU/mL (EPEC). Compared with the conventional PCR, the specificity and sensitivity of the multiplex rtPCR was 100% and over 99%, respectively. The coefficient of variation (CV) for each target gene ranged from 0.45% to 1.53%. 171 positive clinical samples were mostly identified as ETEC (n = 111, 64.9%) and EPEC (n = 38, 22.2%), which were the dominating pathotypes of DEC strains. Conclusion The developed multiplex rtPCR assay for the identification of DEC was high sensitive and specific and could be applied to the rapid identification of DEC in clinical and public health laboratories. PMID:25023669

  6. Determination of nuvenzepine in human plasma by a sensitive sup 3 Hpirenzepine radioreceptor binding assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caselli, G.; Ferrari, M.P.; Tonon, G.

    1991-02-01

    A sensitive method for the quantitation of small amounts of nuvenzepine, a new M1-selective antimuscarinic drug, in plasma is described. The analytical method involves the use of a radioreceptor binding assay based on {sup 3}Hpirenzepine displacement in rat cerebral cortex homogenates; no previous extraction is required. The method is reliable, with an interassay CV ranging from 5 to 10%, and allows the analysis of greater than 100 samples/experiment. The limit of detection is {approximately} 0.1 ng/assay. Using this method we have determined the plasma levels of nuvenzepine in eight healthy volunteers treated PO with 15 or 25 mg of nuvenzepine.HCl.more » The pharmacokinetic parameters obtained were (for 15 and 25 mg): Cmax, 64 and 131 ng/mL; AUC0-infinity, 851 and 1379 ng.h/mL; t1/2, 8.6 and 7.2 h. These values are in good agreement with those obtained using an HPLC method. Therefore, this radioreceptor binding assay proved to be simple, rapid, and specific for the determination of low levels of nuvenzepine in human plasma.« less

  7. EVALUATION OF IMMUNOASSAY METHODS FOR DETERMINATION OF 3,5,6-TRICHLORO-2-PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    EPA Science Inventory

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by the RaPID (TM) commercial immunoassay testing ...

  8. Probe molecules (PrM) approach in adverse outcome pathway (AOP) based high throughput screening (HTS): in vivo discovery for developing in vitro target methods

    EPA Science Inventory

    Efficient and accurate adverse outcome pathway (AOP) based high-throughput screening (HTS) methods use a systems biology based approach to computationally model in vitro cellular and molecular data for rapid chemical prioritization; however, not all HTS assays are grounded by rel...

  9. A rapid Salmonella detection method involving thermophilic helicase-dependent amplification and a lateral flow assay.

    PubMed

    Du, Xin-Jun; Zhou, Tian-Jiao; Li, Ping; Wang, Shuo

    2017-08-01

    Salmonella is a major foodborne pathogen that is widespread in the environment and can cause serious human and animal disease. Since conventional culture methods to detect Salmonella are time-consuming and laborious, rapid and accurate techniques to detect this pathogen are critically important for food safety and diagnosing foodborne illness. In this study, we developed a rapid, simple and portable Salmonella detection strategy that combines thermophilic helicase-dependent amplification (tHDA) with a lateral flow assay to provide a detection result based on visual signals within 90 min. Performance analyses indicated that the method had detection limits for DNA and pure cultured bacteria of 73.4-80.7 fg and 35-40 CFU, respectively. Specificity analyses showed no cross reactions with Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, Enterobacter aerogenes, Shigella and Campylobacter jejuni. The results for detection in real food samples showed that 1.3-1.9 CFU/g or 1.3-1.9 CFU/mL of Salmonella in contaminated chicken products and infant nutritional cereal could be detected after 2 h of enrichment. The same amount of Salmonella in contaminated milk could be detected after 4 h of enrichment. This tHDA-strip can be used for the rapid detection of Salmonella in food samples and is particularly suitable for use in areas with limited equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Rapid determination of 226Ra in environmental samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.

    A new rapid method for the determination of {sup 228}Ra in natural water samples has been developed at the SRNL/EBL (Savannah River National Lab/ Environmental Bioassay Laboratory) that can be used for emergency response or routine samples. While gamma spectrometry can be employed with sufficient detection limits to determine {sup 228}Ra in solid samples (via {sup 228}Ac) , radiochemical methods that employ gas flow proportional counting techniques typically provide lower MDA (Minimal Detectable Activity) levels for the determination of {sup 228}Ra in water samples. Most radiochemical methods for {sup 228}Ra collect and purify {sup 228}Ra and allow for {sup 228}Acmore » daughter ingrowth for ~36 hours. In this new SRNL/EBL approach, {sup 228}Ac is collected and purified from the water sample without waiting to eliminate this delay. The sample preparation requires only about 4 hours so that {sup 228}Ra assay results on water samples can be achieved in < 6 hours. The method uses a rapid calcium carbonate precipitation enhanced with a small amount of phosphate added to enhance chemical yields (typically >90%), followed by rapid cation exchange removal of calcium. Lead, bismuth, uranium, thorium and protactinium isotopes are also removed by the cation exchange separation. {sup 228}Ac is eluted from the cation resin directly onto a DGA Resin cartridge attached to the bottom of the cation column to purify {sup 228}Ac. DGA Resin also removes lead and bismuth isotopes, along with Sr isotopes and {sup 90}Y. La is used to determine {sup 228}Ac chemical yield via ICP-MS, but {sup 133}Ba can also be used instead if ICP-MS assay is not available. Unlike some older methods, no lead or strontium holdback carriers or continual readjustment of sample pH is required.« less

  11. Development of a rapid assay for the diagnosis of Myxobolus cerebralis in fish and oligochaetes using loop-mediated isothermal amplification.

    PubMed

    El-Matbouli, M; Soliman, H

    2005-09-01

    A loop-mediated isothermal amplification assay was developed for the rapid detection of Myxobolus cerebralis in both fish and oligochaete hosts. The assay was optimized to amplify parasitic DNA by incubation with Bst DNA polymerase and a set of six specially constructed primers at 65 degrees C for 60 min. The amplification products were detected visually using SYBR Green I dye which gave identical results to gel electrophoresis analysis. Parasite DNA was detected from infected oligochaetes, and from the anal fin, caudal fin, dorsal fin and operculum of clinically infected fish. This 'Myxo-LAMP' assay has a detection limit similar to that of a polymerase chain reaction assay (10(-6)), but is more rapid and only requires a water bath for amplification and is therefore practical for simple and rapid diagnosis of infected tissue.

  12. Rapid Detection of Herpes Viruses for Clinical Applications

    NASA Technical Reports Server (NTRS)

    Pierson, Duane; Mehta, Satish

    2013-01-01

    There are eight herpes viruses that infect humans, causing a wide range of diseases resulting in considerable morbidity and associated costs. Varicella zoster virus (VZV) is a human herpes virus that causes chickenpox in children and shingles in adults. Approximately 1,000,000 new cases of shingles occur each year; post-herpetic neuralgia (PHN) follows shingles in 100,000 to 200,000 people annually. PHN is characterized by debilitating, nearly unbearable pain for weeks, months, and even years. The onset of shingles is characterized by pain, followed by the zoster rash, leading to blisters and severe pain. The problem is that in the early stages, shingles can be difficult to diagnose; chickenpox in adults can be equally difficult to diagnose. As a result, both diseases can be misdiagnosed (false positive/negative). A molecular assay has been adapted for use in diagnosing VZV diseases. The polymerase chain reaction (PCR) assay is a non-invasive, rapid, sensitive, and highly specific method for VZV DNA detection. It provides unequivocal results and can effectively end misdiagnoses. This is an approximately two-hour assay that allows unequivocal diagnosis and rapid antiviral drug intervention. It has been demonstrated that rapid intervention can prevent full development of the disease, resulting in reduced likelihood of PHN. The technology was extended to shingles patients and demonstrated that VZV is shed in saliva and blood of all shingles patients. The amount of VZV in saliva parallels the medical outcome.

  13. Development of an Immunochromatography Assay (QuickNavi-Ebola) to Detect Multiple Species of Ebolaviruses

    PubMed Central

    Yoshida, Reiko; Muramatsu, Shino; Akita, Hiroshi; Saito, Yuji; Kuwahara, Miwa; Kato, Daisuke; Changula, Katendi; Miyamoto, Hiroko; Kajihara, Masahiro; Manzoor, Rashid; Furuyama, Wakako; Marzi, Andrea; Feldmann, Heinz; Mweene, Aaron; Masumu, Justin; Kapeteshi, Jimmy; Muyembe-Tamfum, Jean-Jacques; Takada, Ayato

    2016-01-01

    The latest outbreak of Ebola virus disease (EVD) in West Africa has highlighted the urgent need for the development of rapid and reliable diagnostic assays. We used monoclonal antibodies specific to the ebolavirus nucleoprotein to develop an immunochromatography (IC) assay (QuickNavi-Ebola) for rapid diagnosis of EVD. The IC assay was first evaluated with tissue culture supernatants of infected Vero E6 cells and found to be capable of detecting 103–104 focus-forming units/mL of ebolaviruses. Using serum samples from experimentally infected nonhuman primates, we confirmed that the assay could detect the viral antigen shortly after disease onset. It was also noted that multiple species of ebolaviruses could be detected by the IC assay. Owing to the simplicity of the assay procedure and absence of requirements for special equipment and training, QuickNavi-Ebola is expected to be a useful tool for rapid diagnosis of EVD. PMID:27462094

  14. Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study.

    PubMed

    Smart, Luke R; Ambrose, Emmanuela E; Raphael, Kevin C; Hokororo, Adolfine; Kamugisha, Erasmus; Tyburski, Erika A; Lam, Wilbur A; Ware, Russell E; McGann, Patrick T

    2018-02-01

    Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.

  15. A rapid method for determining salinomycin and monensin sensitivity in Eimeria tenella.

    PubMed

    Jenkins, M C; O'Brien, C N; Fuller, L; Mathis, G F; Fetterer, R

    2014-12-15

    Standard methods of determining the ionophore sensitivity of Eimeria rely on infecting chickens with an isolate or a mixture of Eimeria spp. oocysts in the presence of different anti-coccidial drugs. The purpose of this study was to develop a rapid in vitro method for assessing salinomycin and monensin sensitivity in Eimeria tenella. Cultures of MDBK cells were grown to 85% confluency, and then inoculated with excysted E. tenella laboratory strain (APU-1) sporozoites in the presence of different concentrations of salinomycin or monensin. At various timepoints, the monolayers were fixed for counting intraceullar sporozoites, or were subjected to DNA extraction, followed by molecular analysis using quantitative (qPCR) or semi-quantitative PCR (sqPCR). Preliminary experiments showed that 24h was the optimum time for harvesting the E. tenella-infected cell cultures. The average number of E. tenella sporozoites relative to untreated controls displayed a linear decrease between 0.3 and 33.0 μg/ml salinomycin and between 0.3 and 3.3 μg/ml monensin. A similar pattern was observed in the relative amount of E. tenella DNA as measured by sqPCR. A linear decrease in the relative amount of E. tenella DNA was observed over the entire range of salinomycin and monensin concentrations as measured by qPCR possibly reflecting the greater sensitivity of this assay. Comparison of sporozoite counting, sqPCR, and qPCR signals using a criterion of 50% inhibition in sporozoite numbers or level of PCR amplification product showed good agreement between the three assays. E. tenella field isolates (FS-1 and FS-2) displaying resistance to salinomycin and monensin were evaluated in the in vitro assay using qPCR and sqPCR. Compared to E. tenella APU-1, the E. tenella FS-1 and FS-2 isolates showed higher levels of E. tenella DNA at 24h by both qPCR and sqPCR. This in vitro assay represents a significant advance in developing rapid, cost-effective methods for assessing ionophore sensitivity in E. tenella. Published by Elsevier B.V.

  16. Validation of the ANSR Listeria method for detection of Listeria spp. in environmental samples.

    PubMed

    Wendorf, Michael; Feldpausch, Emily; Pinkava, Lisa; Luplow, Karen; Hosking, Edan; Norton, Paul; Biswas, Preetha; Mozola, Mark; Rice, Jennifer

    2013-01-01

    ANSR Listeria is a new diagnostic assay for detection of Listeria spp. in sponge or swab samples taken from a variety of environmental surfaces. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in 40 min, requiring only simple instrumentation. In inclusivity testing, 48 of 51 Listeria strains tested positive, with only the three strains of L. grayi producing negative results. Further investigation showed that L. grayi is reactive in the ANSR assay, but its ability to grow under the selective enrichment conditions used in the method is variable. In exclusivity testing, 32 species of non-Listeria, Gram-positive bacteria all produced negative ANSR assay results. Performance of the ANSR method was compared to that of the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of Listeria spp. in sponge or swab samples taken from inoculated stainless steel, plastic, ceramic tile, sealed concrete, and rubber surfaces. Data were analyzed using Chi-square and probability of detection models. Only one surface, stainless steel, showed a significant difference in performance between the methods, with the ANSR method producing more positive results. Results of internal trials were supported by findings from independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in environmental samples.

  17. A sensitive and rapid assay for 4-aminophenol in paracetamol drug and tablet formulation, by flow injection analysis with spectrophotometric detection.

    PubMed

    Bloomfield, M S

    2002-12-06

    4-Aminophenol (4AP) is the primary degradation product of paracetamol which is limited at a low level (50 ppm or 0.005% w/w) in the drug substance by the European, United States, British and German Pharmacopoeias, employing a manual colourimetric limit test. The 4AP limit is widened to 1000 ppm or 0.1% w/w for the tablet product monographs, which quote the use of a less sensitive automated HPLC method. The lower drug substance specification limit is applied to our products, (50 ppm, equivalent to 25 mug 4AP in a tablet containing 500-mg paracetamol) and the pharmacopoeial HPLC assay was not suitable at this low level due to matrix interference. For routine analysis a rapid, automated assay was required. This paper presents a highly sensitive, precise and automated method employing the technique of Flow Injection (FI) analysis to quantitatively assay low levels of this degradant. A solution of the drug substance, or an extract of the tablets, containing 4AP and paracetamol is injected into a solvent carrier stream and merged on-line with alkaline sodium nitroprusside reagent, to form a specific blue derivative which is detected spectrophotometrically at 710 nm. Standard HPLC equipment is used throughout. The procedure is fully quantitative and has been optimised for sensitivity and robustness using a multivariate experimental design (multi-level 'Central Composite' response surface) model. The method has been fully validated and is linear down to 0.01 mug ml(-1). The approach should be applicable to a range of paracetamol products.

  18. Rapid detection of D-Dimers with mLabs® whole blood method for venous thromboembolism exclusion. Comparison with Vidas® D-Dimers assay.

    PubMed

    Gerotziafas, Grigoris T; Ray, Patrick; Gkalea, Vasiliki; Benzarti, Ahlem; Khaterchi, Amir; Cast, Claire; Pernet, Julie; Lefkou, Eleftheria; Elalamy, Ismail

    2016-12-01

    Easy to use point of care assays for D-Dimers measurement in whole blood from patients with clinical suspicion of venous thromboembolism (VTE) will facilitate the diagnostic strategy in the Emergency Department (ED) setting. We prospectively evaluated the diagnostic performance of the point-of-care mLabs® Whole Blood D-Dimers test and we compared it with the Vidas® D-Dimers assay. As part of the diagnostic algorithm applied in patients with clinical suspicion of VTE, the VIDAS® D-Dimers Test was prescribed by the emergency physician in charge. The mLabs® Whole Blood D-Dimers Test was used on the same samples. All patients had undergone exploration with the recommended imaging techniques for VTE diagnosis. Both assays were performed, on 99 emergency patients (mean age was 65 years) with clinical suspicion of VTE. In 3% of patients, VTE was documented with a reference imaging technique. The Bland and Altman test showed significant agreement between the two methods. Both assays showed equal sensitivity and negative predictive value for VTE. The mLabs whole blood assay is a promising point of care method for measurement of D-Dimers and exclusion of VTE diagnosis in the emergency setting which should be validated in a larger prospective study.

  19. [Identification of hepatitis B virus YMDD point mutation using peptide nucleic acid clamping PCR].

    PubMed

    Zhang, Yingying; He, Haitang; Yang, Jie; Hou, Jinlin

    2013-06-01

    To establish a peptide nucleic acid clamping PCR assay for detecting hepatitis B virus (HBV) drug resistance mutation. RtM204I (ATT) mutant, rtM204V (GTG) mutant and rtM204 (ATG) wild-type plasmids mixed at different ratios were detected for mutations by PNA clamping PCR assay and direct sequencing, and the sensitivity and specificity of the two methods were compared. Serum samples from 85 patients with chronic HBV infection were detected for drug resistance using the two methods. The sensitivity of PNA-PCR assay was 0.001% in a 10(5)-fold excess of wild-type HBV DNA with a detection limit of 10(1) copies. The sensitivity of direct sequencing was 10% with a detection limit of 10(4) copies. Mutants were detected in 73 of the 85 serum samples (85.9%), including YIDD in 40 samples, YVDD in 23 samples, and YIDD+YVDD in 10 samples. The agreement of PNA-PCR assay with direct sequencing was only 40% (34/85, YIDD in 21 samples, YVDD in 11 samples, and YIDD+YVDD in 2 samples). Neither of the two methods yielded positive results for the negative control samples, suggesting their good specificity. PNA-PCR assay appears to be a more sensitive and rapid assay for detection of HBV genotypic resistance.

  20. A Complementary Isothermal Amplification Method to the U.S. EPA Quantitative Polymerase Chain Reaction Approach for the Detection of Enterococci in Environmental Waters

    PubMed Central

    2017-01-01

    We report a novel molecular assay, based on helicase-dependent amplification (HDA), for the detection of enterococci as markers for fecal pollution in water. This isothermal assay targets the same Enterococcus 23S rRNA gene region as the existing quantitative polymerase chain reaction (qPCR) assays of U.S. Environmental Protection Agency Methods 1611 and 1609 but can be entirely performed on a simple heating block. The developed Enterococcus HDA assay successfully discriminated 15 enterococcal from 15 non-enterococcal reference strains and reliably detected 48 environmental isolates of enterococci. The limit of detection was 25 target copies per reaction, only 3 times higher than that of qPCR. The applicability of the assay was tested on 30 environmental water sample DNA extracts, simulating a gradient of fecal pollution. Despite the isothermal nature of the reaction, the HDA results were consistent with those of the qPCR reference. Given this performance, we conclude that the developed Enterococcus HDA assay has great potential as a qualitative molecular screening method for resource-limited settings when combined with compatible up- and downstream processes. This amplification strategy can pave the way for developing a new generation of rapid, low-cost, and field-deployable molecular diagnostic tools for water quality monitoring. PMID:28541661

  1. Detection and Quantification of Human Fecal Pollution with Real-Time PCR

    EPA Science Inventory

    ABSTRACT Assessment of health risk and fecal bacteria loads associated with human fecal pollution requires a reliable host-specific genetic marker and a rapid quantification method. We report the development of quantitative PCR assays for enumeration of two recently described ...

  2. Screening for anthracnose disease resistance in strawberry using a detached leaf assay

    USDA-ARS?s Scientific Manuscript database

    Inoculation of detached strawberry leaves with Colletotrichum species may provide a rapid, non-destructive method of identifying anthracnose resistant germplasm. The reliability and validity of assessing disease severity is critical to disease management decisions. We inoculated detached strawberr...

  3. The microculture tetrazolium assay (MTA): another colorimetric method of testing Plasmodium falciparum chemosensitivity.

    PubMed

    Delhaes, L; Lazaro, J E; Gay, F; Thellier, M; Danis, M

    1999-01-01

    Malarial lactate dehydrogenase (LDH), which uses 3-acetyl pyridine adenine dinucleotide as coenzyme in a reaction leading to the formation of pyruvate from L-lactate, may be used to study the susceptibility of Plasmodium falciparum to a drug in vitro. Several methods to determine the activity of this enzyme are available. One, the colorimetric method of Makler and colleagues, was modified slightly, by using sodium-2,3-bis-[2-methoxy-4-nitro-5-sulphophenyl]-2H-tetrazolium-5 - carboxanilide (XTT) and following the reaction by measuring the optical density at 450 nm. Using two, culture-adapted strains of P. falciparum, this LDH assay was compared with the unmodified Makler's assay and with the isotopic microtest based on the incorporation of tritium-labelled hypoxanthine. Fresh, clinical P. falciparum isolates were also tested in the presence of several drugs, including chloroquine, mefloquine, quinine, halofantrine, atovaquone and qinghaosu derivatives. The results of the three assays were correlated for all the drugs tested except atovaquone. The two enzymatic assays are non-radioactive, rapid, reliable, inexpensive to perform and semi-automatic. However, they do require an initial parasitaemia of 2% with a haematocrit of 1.8%.

  4. Initial experience with GeneXpert MTB/RIF assay in the Arkansas Tuberculosis Control Program.

    PubMed

    Patil, Naveen; Saba, Hamida; Marco, Asween; Samant, Rohan; Mukasa, Leonard

    2014-01-01

    Mycobacterium tuberculosis remains one of the most significant causes of death from an infectious agent. Rapid and accurate diagnosis of pulmonary and extra-pulmonary tuberculosis (TB) is still a great challenge. The GeneXpert MTB/RIF assay is a novel integrated diagnostic system for the diagnosis of tuberculosis and rapid detection of Rifampin (RIF) resistance in clinical specimens. In 2012, the Arkansas Tuberculosis Control Program introduced GeneXpert MTB/RIF assay to replace the labour-intensive Mycobacterium Tuberculosis Direct (MTD) assay. To rapidly diagnose TB within two hours and to simultaneously detect RIF resistance. Describe the procedure used to introduce GeneXpert MTB/RIF assay in the Arkansas Tuberculosis Control Program.Characterise the current gap in rapid M. tuberculosis diagnosis in Arkansas.Assess factors that predict acid fast bacilli (AFB) smearnegative but culture-positive cases in Arkansas.Illustrate, with two case reports, the role of GeneXpert MTB/RIF assay in reduction of time to confirmation of M. tuberculosis diagnosis in the first year of implementation. Between June 2012 and June 2013, all AFB sputum smearpositive cases and any others, on request by the physician, had GeneXpert MTB/RIF assay performed as well as traditional M. tuberculosis culture and susceptibilities using Mycobacteria Growth Indicator Tube (MGIT) 960 and Löwenstein-Jensen (LJ) slants. Surveillance data for January 2009-June 2013 was analysed to characterise sputum smear-negative but culture-positive cases. Seventy-one TB cases were reported from June 2012- June 2013. GeneXpert MTB/RIF assay identified all culture-positive cases as well as three cases that were negative on culture. Also, this rapid assay identified all six smear-negative but M. tuberculosis culture-positive cases; two of these cases are described as case reports. GeneXpert MTB/RIF assay has made rapid TB diagnosis possible, with tremendous potential in determining isolation of TB suspects on one hand, and quickly ruling out TB whenever suspected.

  5. Development of Prototype Filovirus Recombinant Antigen Immunoassays

    PubMed Central

    Boisen, Matt L.; Oottamasathien, Darin; Jones, Abigail B.; Millett, Molly M.; Nelson, Diana S.; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shun-ichiro; Hartnett, Jessica N.; Rowland, Megan M.; Heinrich, Megan L.; Akdag, Marjan; Goba, Augustine; Momoh, Mambu; Fullah, Mohammed; Baimba, Francis; Gbakie, Michael; Safa, Sadiki; Fonnie, Richard; Kanneh, Lansana; Cross, Robert W.; Geisbert, Joan B.; Geisbert, Thomas W.; Kulakosky, Peter C.; Grant, Donald S.; Shaffer, Jeffery G.; Schieffelin, John S.; Wilson, Russell B.; Saphire, Erica Ollmann; Branco, Luis M.; Garry, Robert F.; Khan, S. Humarr; Pitts, Kelly R.

    2015-01-01

    Background. Throughout the 2014–2015 Ebola outbreak in West Africa, major gaps were exposed in the availability of validated rapid diagnostic platforms, protective vaccines, and effective therapeutic agents. These gaps potentiated the development of prototype rapid lateral flow immunodiagnostic (LFI) assays that are true point-of-contact platforms, for the detection of active Ebola infections in small blood samples. Methods. Recombinant Ebola and Marburg virus matrix VP40 and glycoprotein (GP) antigens were used to derive a panel of monoclonal and polyclonal antibodies. Antibodies were tested using a multivariate approach to identify antibody-antigen combinations suitable for enzyme-linked immunosorbent assay (ELISA) and LFI assay development. Results. Polyclonal antibodies generated in goats were superior reagents for capture and detection of recombinant VP40 in test sample matrices. These antibodies were optimized for use in antigen-capture ELISA and LFI assay platforms. Prototype immunoglobulin M (IgM)/immunoglobulin G (IgG) ELISAs were similarly developed that specifically detect Ebola virus–specific antibodies in the serum of experimentally infected nonhuman primates and in blood samples obtained from patients with Ebola from Sierra Leone. Conclusions. The prototype recombinant Ebola LFI assays developed in these studies have sensitivities that are useful for clinical diagnosis of acute ebolavirus infections. The antigen-capture and IgM/IgG ELISAs provide additional confirmatory assay platforms for detecting VP40 and other ebolavirus-specific immunoglobulins. PMID:26232440

  6. A gold immunochromatographic assay for the rapid and simultaneous detection of fifteen β-lactams

    NASA Astrophysics Data System (ADS)

    Chen, Yanni; Wang, Yongwei; Liu, Liqiang; Wu, Xiaoling; Xu, Liguang; Kuang, Hua; Li, Aike; Xu, Chuanlai

    2015-10-01

    A novel gold immunochromatographic assay (GICA) based on anti-β-lactam receptors was innovatively developed that successfully allowed rapid and simultaneous detection of fifteen β-lactams in milk samples in 5-10 minutes. By replacing the antibodies used in traditional GICA with anti-β-lactam receptors, the difficulty in producing broad specific antibodies against β-lactams was overcome. Conjugates of ampicillin with BSA and goat anti-mouse immunoglobulin (IgG) were immobilized onto the test and control lines on the nitrocellulose membrane, respectively. Since goat anti-mouse IgG does not combine with receptors, negative serum from mice labelled with gold nanoparticles (GNP) was mixed with GNP-labelled receptors. Results were obtained within 20 min using a paper-based sensor. The utility of the assay was confirmed by the analysis of milk samples. The limits of detection (LOD) for amoxicillin, ampicillin, penicillin G, penicillin V, cloxacillin, dicloxacillin, nafcillin, oxacillin, cefaclor, ceftezole, cefotaxime, ceftiofur, cefoperazone, cefathiamidine, and cefepime were 0.25, 0.5, 0.5, 0.5, 1, 5, 5, 10, 25, 10, 100, 10, 5, 5, and 2 ng mL-1, respectively, which satisfies the maximum residue limits (MRL) set by the European Union (EU). In conclusion, our newly developed GICA-based anti-β-lactam receptor assay provides a rapid and effective method for one-site detection of multiple β-lactams in milk samples.A novel gold immunochromatographic assay (GICA) based on anti-β-lactam receptors was innovatively developed that successfully allowed rapid and simultaneous detection of fifteen β-lactams in milk samples in 5-10 minutes. By replacing the antibodies used in traditional GICA with anti-β-lactam receptors, the difficulty in producing broad specific antibodies against β-lactams was overcome. Conjugates of ampicillin with BSA and goat anti-mouse immunoglobulin (IgG) were immobilized onto the test and control lines on the nitrocellulose membrane, respectively. Since goat anti-mouse IgG does not combine with receptors, negative serum from mice labelled with gold nanoparticles (GNP) was mixed with GNP-labelled receptors. Results were obtained within 20 min using a paper-based sensor. The utility of the assay was confirmed by the analysis of milk samples. The limits of detection (LOD) for amoxicillin, ampicillin, penicillin G, penicillin V, cloxacillin, dicloxacillin, nafcillin, oxacillin, cefaclor, ceftezole, cefotaxime, ceftiofur, cefoperazone, cefathiamidine, and cefepime were 0.25, 0.5, 0.5, 0.5, 1, 5, 5, 10, 25, 10, 100, 10, 5, 5, and 2 ng mL-1, respectively, which satisfies the maximum residue limits (MRL) set by the European Union (EU). In conclusion, our newly developed GICA-based anti-β-lactam receptor assay provides a rapid and effective method for one-site detection of multiple β-lactams in milk samples. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr04987c

  7. Development and Evaluation of a Blocking Enzyme-Linked Immunosorbent Assay and Virus Neutralization Assay To Detect Antibodies to Viral Hemorrhagic Septicemia Virus

    PubMed Central

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV. PMID:24429071

  8. Detection and quantification of serum or plasma HCV RNA: mini review of commercially available assays.

    PubMed

    Le Guillou-Guillemette, Helene; Lunel-Fabiani, Francoise

    2009-01-01

    The treatment schedule (combination of compounds, doses, and duration) and the virological follow-up for management of antiviral treatment in patients chronically infected by HCV is now well standardized, but to ensure good monitoring of the treated patients, physicians need rapid, reproducible, and sensitive molecular virological tools with a wide range of detection and quantification of HCV RNA in blood samples. Several assays for detection and/or quantification of HCV RNA are currently commercially available. Here, all these assays are detailed, and a brief description of each step of the assay is provided. They are divided into two categories by method: those based on signal amplification and those based on target amplification. These two categories are then divided into qualitative, quantitative, and quantitative detection assays. The real-time reverse-transcription polymerase chain reaction (RT-PCR)-based assays are the most promising strategy in the HCV virological area.

  9. Rapid screening and identification of dominant B cell epitopes of HBV surface antigen by quantum dot-based fluorescence polarization assay

    NASA Astrophysics Data System (ADS)

    Meng, Zhongji; Song, Ruihua; Chen, Yue; Zhu, Yang; Tian, Yanhui; Li, Ding; Cui, Daxiang

    2013-03-01

    A method for quickly screening and identifying dominant B cell epitopes was developed using hepatitis B virus (HBV) surface antigen as a target. Eleven amino acid fragments from HBV surface antigen were synthesized by 9-fluorenylmethoxy carbonyl solid-phase peptide synthesis strategy, and then CdTe quantum dots were used to label the N-terminals of all peptides. After optimizing the factors for fluorescence polarization (FP) immunoassay, the antigenicities of synthetic peptides were determined by analyzing the recognition and combination of peptides and standard antibody samples. The results of FP assays confirmed that 10 of 11 synthetic peptides have distinct antigenicities. In order to screen dominant antigenic peptides, the FP assays were carried out to investigate the antibodies against the 10 synthetic peptides of HBV surface antigen respectively in 159 samples of anti-HBV surface antigen-positive antiserum. The results showed that 3 of the 10 antigenic peptides may be immunodominant because the antibodies against them existed more widely among the samples and their antibody titers were higher than those of other peptides. Using three dominant antigenic peptides, 293 serum samples were detected for HBV infection by FP assays; the results showed that the antibody-positive ratio was 51.9% and the sensitivity and specificity were 84.3% and 98.2%, respectively. In conclusion, a quantum dot-based FP assay is a very simple, rapid, and convenient method for determining immunodominant antigenic peptides and has great potential in applications such as epitope mapping, vaccine designing, or clinical disease diagnosis in the future.

  10. Evaluating the Effect of Peptoid Lipophilicity on Antimicrobial Potency, Cytotoxicity, and Combinatorial Library Design.

    PubMed

    Turkett, Jeremy A; Bicker, Kevin L

    2017-04-10

    Growing prevalence of antibiotic resistant bacterial infections necessitates novel antimicrobials, which could be rapidly identified from combinatorial libraries. We report the use of the peptoid library agar diffusion (PLAD) assay to screen peptoid libraries against the ESKAPE pathogens, including the optimization of assay conditions for each pathogen. Work presented here focuses on the tailoring of combinatorial peptoid library design through a detailed study of how peptoid lipophilicity relates to antibacterial potency and mammalian cell toxicity. The information gleaned from this optimization was then applied using the aforementioned screening method to examine the relative potency of peptoid libraries against Staphylococcus aureus, Acinetobacter baumannii, and Enterococcus faecalis prior to and following functionalization with long alkyl tails. The data indicate that overall peptoid hydrophobicity and not simply alkyl tail length is strongly correlated with mammalian cell toxicity. Furthermore, this work demonstrates the utility of the PLAD assay in rapidly evaluating the effect of molecular property changes in similar libraries.

  11. Rapid identification of the NAT2 genotype in tuberculosis patients by multicolor melting curve analysis.

    PubMed

    Hu, Yanjie; Chen, Suting; Yu, Xia; Dai, Guangming; Dong, Lingling; Li, Yunxu; Zhao, Liping; Huang, Hairong

    2016-07-01

    NAT2 genotype is an indicator for isoniazid dosage adjusting for tuberculosis treatment. Multicolor melting curve analysis (MMCA) was evaluated as a potential method for NAT2 genotyping. 352 blood samples were analyzed by MMCA kit (Zeesan Biotech Co., Xiamen, China) targeting NAT2 SNPs at T341C, C481T, G590A and G857A, and direct sequencing was used as control. The sensitivity, specificity and accuracy of the MMCA assay for rapid NAT2 genotype detection were 97.9, 99.6 and 99.1% respectively, whereas for intermediate genotypes the values were 99.5, 98.7 and 99.1%, respectively, and for slow genotypes the values were 100% for the three aspects. The 24 saliva and blood for the control samples were also successfully analyzed using the MMCA assay, both produced uniform outcomes. The MMCA assay described in our study is very promising for the efficient determination of NAT2 genotype, and can facilitate the personalized dosing of isoniazid.

  12. A recombinase polymerase amplification-based assay for rapid detection of African swine fever virus.

    PubMed

    Wang, Jianchang; Wang, Jinfeng; Geng, Yunyun; Yuan, Wanzhe

    2017-10-01

    A recombinase polymerase amplification (RPA)-based method was developed for rapid and specific detection of African swine fever virus (ASFV), the etiologic agent of African swine fever, a devastating disease of swine. Primers and the exo probe targeting the conserved region of the P72 gene of ASFV were designed and the reaction was run on the Genie III scanner device. Using recombinant plasmid DNA containing the P72 gene as template, we showed that the amplified product could be detected in less than 10 min and that the detection limit was 10 2 copies DNA/reaction [same detection limit as real-time polymerase chain reaction (PCR)]. The RPA assay did not cross-detect CSFV, PCV-2, PRV, PRRSV, or FMDV, common viruses seen in pigs. Tests of recombinant plasmid-spiked serum samples revealed that RPA and real-time PCR had the same diagnostic rate. The RPA assay, which is simple, cost-effective, and fast, is a promising alternative to real-time PCR for ASFV detection.

  13. A recombinase polymerase amplification-based assay for rapid detection of African swine fever virus

    PubMed Central

    Wang, Jianchang; Wang, Jinfeng; Geng, Yunyun; Yuan, Wanzhe

    2017-01-01

    A recombinase polymerase amplification (RPA)-based method was developed for rapid and specific detection of African swine fever virus (ASFV), the etiologic agent of African swine fever, a devastating disease of swine. Primers and the exo probe targeting the conserved region of the P72 gene of ASFV were designed and the reaction was run on the Genie III scanner device. Using recombinant plasmid DNA containing the P72 gene as template, we showed that the amplified product could be detected in less than 10 min and that the detection limit was 102 copies DNA/reaction [same detection limit as real-time polymerase chain reaction (PCR)]. The RPA assay did not cross-detect CSFV, PCV-2, PRV, PRRSV, or FMDV, common viruses seen in pigs. Tests of recombinant plasmid-spiked serum samples revealed that RPA and real-time PCR had the same diagnostic rate. The RPA assay, which is simple, cost-effective, and fast, is a promising alternative to real-time PCR for ASFV detection. PMID:29081590

  14. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...

  15. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...

  16. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...

  17. Development of an isothermal recombinase polymerase amplification assay for rapid detection of pseudorabies virus.

    PubMed

    Yang, Yang; Qin, Xiaodong; Zhang, Wei; Li, Zhiyong; Zhang, Shuaijun; Li, Yanmin; Zhang, Zhidong

    2017-06-01

    Recombinase polymerase amplification assays using real-time fluorescent detection (real-time RPA assay) and lateral flow dipstick (RPA LFD assay) were developed targeting the gD gene of pseudorabies virus (PRV). Both assays were performed at 39 °C within 20 min. The sensitivity of the real-time RPA assay and the RPA LFD assay was 100 copies per reaction and 160 copies per reaction, respectively. Both assays did not detect DNAs from other virus or PRV negative samples. Therefore, the developed RPA assays provide a rapid, simple, sensitive and specific alternative tool for detection of PRV. Copyright © 2017. Published by Elsevier Ltd.

  18. Simple genetic transformation assay for rapid diagnosis of Moraxella osloensis.

    PubMed

    Juni, E

    1974-01-01

    A genetic transformation assay for unequivocal identification of strains of Moraxella osloensis is described. In this assay a stable tryptophan auxotroph is transformed to prototrophy by deoxyribonucleic acid (DNA) samples from other strains of M. osloensis but not by DNA samples from unrelated bacteria. The test is simple to perform and definitive results can be obtained in less than 24 h. The procedure, which is suitable for routine diagnosis in a clinical laboratory, involves a rapid method for preparation of crude transforming DNA from small quantities of bacterial cells and permits simultaneous examination of large numbers of isolated cultures. The assay was shown to correctly identify 27 strains previously classified as M. osloensis. Forty-five other gram-negative, oxidase-positive, nonmotile coccobacilli, which might be confused with M. osloensis unless subject to more extensive testing, were shown to be unrelated genetically to M. osloensis. The transformation assay clearly distinguishes M. osloensis from Acinetobacter. Although most strains of M. osloensis are nonfastidious, being able to grow in a mineral medium supplemented with a single organic carbon source, one of the strains tested was only able to grow on fairly complex media and could not be transformed to grow on simple media. Inability to alkalize Simmons citrate agar was shown not to be characteristic of all strains of M. osloensis.

  19. Simple Genetic Transformation Assay for Rapid Diagnosis of Moraxella osloensis

    PubMed Central

    Juni, Elliot

    1974-01-01

    A genetic transformation assay for unequivocal identification of strains of Moraxella osloensis is described. In this assay a stable tryptophan auxotroph is transformed to prototrophy by deoxyribonucleic acid (DNA) samples from other strains of M. osloensis but not by DNA samples from unrelated bacteria. The test is simple to perform and definitive results can be obtained in less than 24 h. The procedure, which is suitable for routine diagnosis in a clinical laboratory, involves a rapid method for preparation of crude transforming DNA from small quantities of bacterial cells and permits simultaneous examination of large numbers of isolated cultures. The assay was shown to correctly identify 27 strains previously classified as M. osloensis. Forty-five other gram-negative, oxidase-positive, nonmotile coccobacilli, which might be confused with M. osloensis unless subject to more extensive testing, were shown to be unrelated genetically to M. osloensis. The transformation assay clearly distinguishes M. osloensis from Acinetobacter. Although most strains of M. osloensis are nonfastidious, being able to grow in a mineral medium supplemented with a single organic carbon source, one of the strains tested was only able to grow on fairly complex media and could not be transformed to grow on simple media. Inability to alkalize Simmons citrate agar was shown not to be characteristic of all strains of M. osloensis. Images PMID:4589126

  20. SERS Assay for Copper(II) Ions Based on Dual Hot-Spot Model Coupling with MarR Protein: New Cu2+-Specific Biorecognition Element.

    PubMed

    Wang, Yulong; Su, Zhenhe; Wang, Limin; Dong, Jinbo; Xue, Juanjuan; Yu, Jiao; Wang, Yuan; Hua, Xiude; Wang, Minghua; Zhang, Cunzheng; Liu, Fengquan

    2017-06-20

    We have developed a rapid and ultrasensitive surface-enhanced Raman scattering (SERS) assay for Cu 2+ detection using the multiple antibiotic resistance regulator (MarR) as specific bridging molecules in a SERS hot-spot model. In the assay, Cu 2+ induces formation of MarR tetramers, which provide Au nanoparticle (NP)-AuNP bridges, resulting in the formation of SERS hot spots. 4-Mercaptobenzoic acid (4-MBA) was used as a Raman reporter. The addition of Cu 2+ increased the Raman intensity of 4-MBA. Use of a dual hot-spot signal-amplification strategy based on AuNP-AgNP heterodimers combined through antigen-antibody reactions increased the sensitivity of the sensing platform by 50-fold. The proposed method gave a linear response for Cu 2+ detection in the range of 0.5-1000 nM, with a detection limit of 0.18 nM, which is 5 orders of magnitude lower than the U.S. Environmental Protection Agency limit for Cu 2+ in drinking water (20 μM). In addition, all analyses can be completed in less than 15 min. The high sensitivity, high specificity, and rapid detection capacity of the SERS assay therefore provide a combined advantage over current assays.

  1. Rapid and sensitive sandwich enzyme-linked immunosorbent assay for detection of staphylococcal enterotoxin B in cheese.

    PubMed Central

    Morissette, C; Goulet, J; Lamoureux, G

    1991-01-01

    A rapid and sensitive screening sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection of staphylococcal enterotoxin B (SEB) in cheese by using a highly avid anti-SEB antibody (Ab) as the capture Ab (CAb) and as the biotinylated Ab conjugate. The glutaraldehyde fixation method for the immobilization of CAb on polystyrene dipsticks was superior to the adsorption fixation and the adsorption-glutaraldehyde fixation methods. The glutaraldehyde fixation method resulted in a higher surface-saturating CAb concentration as evaluated by the peroxidase saturation technique and by the ability of the CAb-coated dipstick to discriminate between positive and negative controls (index of discrimination). Of nine blocking agents used alone or in pairs, lysine-human serum albumin, bovine serum albumin, human serum albumin, and gelatin effectively saturated available sites on the CAb-coated dipsticks without causing interference with the antigen-Ab reactions. The addition of 1% polyethylene glycol to the diluent of the biotinylated anti-SEB Ab conjugate improved the detection of SEB. A concentration of 4% polyethylene glycol allowed a 5-min reaction time for the streptavidin-biotin-horseradish peroxidase conjugate. Cheddar cheese homogenate reduced the sensitivity of the SEB assay; however, the sensitivity was restored when 1.6% (wt/vol) of either a nonionic detergent (Mega-9) or two zwitterionic detergents (Zwittergent 3-10 and 3-12 detergent) was added to the diluent. By using the rapid sandwich ELISA, a minimum of 0.5 to 1.0 ng of SEB per ml was detected within 45 min. The whole procedure for the analysis of the cheddar cheese samples was completed within 1 h.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2039234

  2. Rapid screening, identification, and purification of neuraminidase inhibitors from Lithospermum erythrorhizon Sieb.et Zucc. by ultrafiltration with HPLC-ESI-TOF-MS combined with semipreparative HPLC.

    PubMed

    Zhang, Minmin; Zhao, Hengqiang; Zhao, Zhiguo; Yan, Huijiao; Lv, Ruimin; Cui, Li; Yuan, Jinpeng; Wang, Daijie; Geng, Yanling; Liu, Daicheng; Wang, Xiao

    2016-06-01

    We put forward an efficient strategy based on bioassay guidance for the rapid screening, identification, and purification of the neuraminidase inhibitors from traditional Chinese medicines, and apply to the discovery of anti-influenza components from Lithospermiun erythrorhizon Sieb.et Zucc. Ultrafiltration with high-performance liquid chromatography and electrospray ionization time-of-flight mass spectrometry was employed for the rapid screening and preliminarily identification of anti-influenza components from Zicao. Semipreparative high-performance liquid chromatography was used for the rapid separation and purification of the target compounds. NMR spectroscopy, mass spectrometry, and UV spectroscopy were used for further structural identification, and the activity of the compounds was verified by in vitro assay. Five compounds were found to have neuraminidase inhibitory activity by this method. Subsequently, the five compounds were separated by semipreparative high-performance liquid chromatography with the purity over 98% for all of them by high-performance liquid chromatography test. Combined with the NMR spectroscopy, mass spectrometry, and UV spectroscopy data, they were identified as alkannin, acetylalkannin, isobutyrylalkannin, β,β-dimethylacryloylalkannin and isovalerylalkannin. The in vitro assay showed that all five compounds had good neuraminidase inhibitory activities. These results suggested that the method is highly efficient, and it can provide platform and methodology supports for the rapid discovery of anti-influenza active ingredients from complex Chinese herbal medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Novel immunoassay and rapid immunoaffinity chromatography method for the detection and selective extraction of naringin in Citrus aurantium.

    PubMed

    Qu, Huihua; Zhang, Yue; Qu, Baoping; Cheng, Jinjun; Liu, Shuchen; Feng, Shenglan; Wang, Qingguo; Zhao, Yan

    2016-04-01

    In this work, a novel monoclonal antibody specific for naringin was prepared and characterized. Subsequently, an indirect competitive enzyme-linked immunosorbent assay for naringin was developed, with an effective range from 4.8 to 156 ng/mL naringin. Next, an immunoaffinity column was obtained by coupling anti-naringin monoclonal antibodies to CNBr-activated Sepharose 4B and a rapid immunoaffinity chromatography assay for naringin was developed. The immunoaffinity column was used to separate naringin from Citrus aurantium. The results showed that 1 g of the dry Sepharose 4B can couple 10 mg of immunoglobulin G. And the immunoaffinity column can efficiently and specifically capture approximately 250 μg of naringin without cross reacting with its structurally similar compounds. Moreover, our results indicate that the application of immunoaffinity chromatography can simplify the pretreatment and the isolation process greatly compared to conventional methods, providing a potential method for extracting the target component from structurally similar compounds in natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Rapid Identification of Staphylococcus aureus Directly from Blood Cultures by Fluorescence In Situ Hybridization with Peptide Nucleic Acid Probes

    PubMed Central

    Oliveira, Kenneth; Procop, Gary W.; Wilson, Deborah; Coull, James; Stender, Henrik

    2002-01-01

    A new fluorescence in situ hybridization (FISH) method with peptide nucleic acid (PNA) probes for identification of Staphylococcus aureus directly from positive blood culture bottles that contain gram-positive cocci in clusters (GPCC) is described. The test (the S. aureus PNA FISH assay) is based on a fluorescein-labeled PNA probe that targets a species-specific sequence of the 16S rRNA of S. aureus. Evaluations with 17 reference strains and 48 clinical isolates, including methicillin-resistant and methicillin-susceptible S. aureus species, coagulase-negative Staphylococcus species, and other clinically relevant and phylogenetically related bacteria and yeast species, showed that the assay had 100% sensitivity and 96% specificity. Clinical trials with 87 blood cultures positive for GPCC correctly identified 36 of 37 (97%) of the S. aureus-positive cultures identified by standard microbiological methods. The positive and negative predictive values were 100 and 98%, respectively. It is concluded that this rapid method (2.5 h) for identification of S. aureus directly from blood culture bottles that contain GPCC offers important information for optimal antibiotic therapy. PMID:11773123

  5. Establishment of a simple and quantitative immunospot assay for detecting anti-type II collagen antibody using an infrared fluorescence imaging system (IFIS).

    PubMed

    Ota, Shusuke; Kanazawa, Satoshi; Kobayashi, Masaaki; Otsuka, Takanobu; Okamoto, Takashi

    2005-04-01

    Antibodies to type II collagen (col II) have been detected in patients with rheumatoid arthritis and in animal models of collagen induced arthritis. Here, we describe a novel method to detect anti-col II antibodies using an immunospot assay with an infrared fluorescence imaging system. This method showed very high sensitivity and specificity, and was simple, with low background levels. It also showed higher reproducibility and linearity, with a dynamic range of approximately 500-fold, than the conventional immunospot assay with enhanced chemiluminescence detection. Using this method we were able to demonstrate the antibody affinity maturation process in mice immunized with col II. In these immunized mice, although cross-reactive antibodies reacting with other collagen species were detected in earlier stages of immunization, the titers of cross-reactive antibodies rapidly diminished after the antigen boost, concomitantly with the elevation of the anti-col II antibody. The method and its possible applications are discussed.

  6. A microplate reader-based method to quantify NADH-cytochrome b5 reductase activity for diagnosis of recessive congenital methaemoglobinemia.

    PubMed

    Kedar, Prabhakar; Desai, Anand; Warang, Prashant; Colah, Roshan

    2017-05-01

    Congenital methemoglobinemia due to NADH-cytochrome b5 reductase 3 (CYB5R3) deficiencies is an autosomal recessive disorder that occurs sporadically worldwide, A sensitive, accurate, and rapid analysis of NADH-CYB5R enzyme concentrations is necessary for the diagnosis of RCM. Here we present an alternative microplate method that is based on a standard 96-well microplate format and microplate reader that simplify the quantification of NADH-CYB5R activity. TECAN (Infinite 200 PRO series) microplate reader with Tecan's proven Magellan™ software measured the NADH-CYB5R enzyme activity in 250 normal controls and previously diagnosed 25 cases of RCM due to NADH-CYB5R deficiency in the Indian population using 96-well microplates using 200 μl of total reaction mixture and also compared with standard spectrophotometric assay. We have also studied stability of the hemolysate stored at 4 and -20°C temperature. Enzyme activity in all 25 samples ranged from 6.09 to 10.07 IU/g Hb (mean ± SD: 8.08 ± 1.99 IU/g Hb) where as normal control ranged (n = 250) between 13.42 and 21.58 IU/g Hb) (mean ± SD: 17.5 ± 4.08 IU/g of Hb). Data obtained from the microplate reader were compared with standard spectrophotometer method and found 100% concordance using both methods. Microplate method allows differentiating between normal, deficient and intermediate enzyme activity. It was observed that samples had significant loss of activity when stored at 4°C and retained stable activity at -20°C for 1 week time. Our new method, incorporating a whole process of enzyme assay into a microplate format is readily applicable and allows rapid monitoring of enzyme assay. It is readily applicable to quantitative assay on pediatric sample as well as large number of samples for population screening.

  7. A rapid assay for the simultaneous determination of nicotine, cocaine and metabolites in meconium using disposable pipette extraction and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Mozaner Bordin, Dayanne C; Alves, Marcela N R; Cabrices, Oscar G; de Campos, Eduardo G; De Martinis, Bruno Spinosa

    2014-01-01

    Drug abuse by pregnant women is considered a serious public health problem worldwide. Meconium is the first excretion in newborns and has been used as an alternative matrix to evaluate in utero drug exposure. Solid phase extraction (SPE) is widely employed to prepare and clean up samples in the field of forensic analysis. Most SPE products require large volumes of solvent, which culminates in longer sample processing times and increased cost per sample. Disposable pipette extraction (DPX) tips have been used as an alternative to traditional SPE cartridges. They combine efficient and rapid extraction with reduced solvent consumption. The purpose of this study was to develop and validate a method to determine nicotine, cotinine, cocaine, benzoylecgonine, cocaethylene and methyl ester anhydroecgonine in meconium using DPX and gas chromatography-mass spectrometry (GC-MS). Validation results indicated that extraction efficiency ranged 50-98%, accuracy 92-106%, intra-assay precision 4-12% and inter-assay precision 6-12%. Linear calibration curves resulted in R(2) values >0.99, limits of detection ranged from 2.5 to 15 ng/g and the limit of quantitation from 10 to 20 ng/g. The DPX-GC-MS method was shown to selectively analyze trace concentrations of drugs in meconium samples. Finally, the developed and validated method was applied to 50 meconium samples.

  8. Real-Time PCR Typing of Escherichia coli Based on Multiple Single Nucleotide Polymorphisms--a Convenient and Rapid Method.

    PubMed

    Lager, Malin; Mernelius, Sara; Löfgren, Sture; Söderman, Jan

    2016-01-01

    Healthcare-associated infections caused by Escherichia coli and antibiotic resistance due to extended-spectrum beta-lactamase (ESBL) production constitute a threat against patient safety. To identify, track, and control outbreaks and to detect emerging virulent clones, typing tools of sufficient discriminatory power that generate reproducible and unambiguous data are needed. A probe based real-time PCR method targeting multiple single nucleotide polymorphisms (SNP) was developed. The method was based on the multi locus sequence typing scheme of Institute Pasteur and by adaptation of previously described typing assays. An 8 SNP-panel that reached a Simpson's diversity index of 0.95 was established, based on analysis of sporadic E. coli cases (ESBL n = 27 and non-ESBL n = 53). This multi-SNP assay was used to identify the sequence type 131 (ST131) complex according to the Achtman's multi locus sequence typing scheme. However, it did not fully discriminate within the complex but provided a diagnostic signature that outperformed a previously described detection assay. Pulsed-field gel electrophoresis typing of isolates from a presumed outbreak (n = 22) identified two outbreaks (ST127 and ST131) and three different non-outbreak-related isolates. Multi-SNP typing generated congruent data except for one non-outbreak-related ST131 isolate. We consider multi-SNP real-time PCR typing an accessible primary generic E. coli typing tool for rapid and uniform type identification.

  9. Rapid and Simple Detection of Hot Spot Point Mutations of Epidermal Growth Factor Receptor, BRAF, and NRAS in Cancers Using the Loop-Hybrid Mobility Shift Assay

    PubMed Central

    Matsukuma, Shoichi; Yoshihara, Mitsuyo; Kasai, Fumio; Kato, Akinori; Yoshida, Akira; Akaike, Makoto; Kobayashi, Osamu; Nakayama, Haruhiko; Sakuma, Yuji; Yoshida, Tsutomu; Kameda, Yoichi; Tsuchiya, Eiju; Miyagi, Yohei

    2006-01-01

    A simple and rapid method to detect the epidermal growth factor receptor hot spot mutation L858R in lung adenocarcinoma was developed based on principles similar to the universal heteroduplex generator technology. A single-stranded oligonucleotide with an internal deletion was used to generate heteroduplexes (loop-hybrids) bearing a loop in the complementary strand derived from the polymerase chain reaction product of the normal or mutant allele. By placing deletion in the oligonucleotide adjacent to the mutational site, difference in electrophoretic mobility between loop-hybrids with normal and mutated DNA was distinguishable in a native polyacrylamide gel. The method was also modified to detect in-frame deletion mutations of epidermal growth factor receptor in lung adenocarcinomas. In addition, the method was adapted to detect hot spot mutations in the B-type Raf kinase (BRAF) at V600 and in a Ras-oncogene (NRAS) at Q61, the mutations commonly found in thyroid carcinomas. Our mutation detection system, designated the loop-hybrid mobility shift assay was sensitive enough to detect mutant DNA comprising 7.5% of the total DNA. As a simple and straightforward mutation detection technique, loop-hybrid mobility shift assay may be useful for the molecular diagnosis of certain types of clinical cancers. Other applications are also discussed. PMID:16931592

  10. Rapid detection of Porcine circovirus 2 by recombinase polymerase amplification.

    PubMed

    Wang, Jianchang; Wang, Jinfeng; Liu, Libing; Li, Ruiwen; Yuan, Wanzhe

    2016-09-01

    Porcine circovirus-associated disease, caused primarily by Porcine circovirus 2 (PCV-2), has become endemic in many pig-producing countries and has resulted in significant economic losses to the swine industry worldwide. Tests for PCV-2 infection include PCR, nested PCR, competitive PCR, and real-time PCR (rtPCR). Recombinase polymerase amplification (RPA) has emerged as an isothermal gene amplification technology for the molecular detection of infectious disease agents. RPA is performed at a constant temperature and therefore can be carried out in a water bath. In addition, RPA is completed in ~30 min, much faster than PCR, which usually takes >60 min. We developed a RPA-based method for the detection of PCV-2. The detection limit of RPA was 10(2) copies of PCV-2 genomic DNA. RPA showed the same sensitivity as rtPCR but was 10 times more sensitive than conventional PCR. Successful amplification of PCV-2 DNA, but not other viral templates, demonstrated high specificity of the RPA assay. This method was also validated using clinical samples. The results showed that the RPA assay had a diagnostic agreement rate of 93.7% with conventional PCR and 100% with rtPCR. These findings suggest that the RPA assay is a simple, rapid, and cost-effective method for PCV-2 detection, which could be potentially applied in clinical diagnosis and field surveillance of PCV-2 infection. © 2016 The Author(s).

  11. A rapid qualitative assay for detection of Clostridium perfringens in canned food products.

    PubMed

    Dave, Gayatri Ashwinkumar

    2017-01-01

    Clostridium perfringens (MTCC 1349) is a Gram-positive, anaerobic, endospore forming, and rod-shaped bacterium. This bacterium produces a variety of toxins under strict anaerobic environment. C. perfringens can grow at temperatures ranging between 20°C and 50°C. It is the major causetive agent for gas gangrene, cellulitis, septicemia, necrotic enteritis and food poisoning, which are common toxin induced conditions noted in human and animals. C. perfringens can produce produce four major types of toxins that are used for the classification of strains, classified under type A-E. Across the globe many countries, including the United States, are affected by C. perfringens food poisonings where it is ranked as one of the most common causes of food borne infections. To date, no direct one step assay for the detection of C. perfringens has been developed and only few methods are known for accurate detection of C. perfringens. Long detection and incubation time is the major consideration of these reporter assays. The prensent study proposes a rapid and reliable colorimetric assay for the detection of C. perfringens. In principale, this assay detects the para nitrophenyl (yellow colour end product) liberated due to the hydrolysis of paranitrophenyl phosphetidyl choline (PNPC) through phospholipase C (lecithinase). Constitutive secretion of phospholipase C is a charactristic feature of C. perfringens. This assay detects the presence of the extracellular lecithinse through the PNPC impragnated impregnated probe. The probe is impregnated with peranitrophenyl phosphotidyl choline ester, which is colourless substrate used by lecithinase. The designed assay is specific towards PNPC and detectes very small quantites of lecithinase under conditions used. The reaction is substrate specific, no cross reaction was observed upon incubation with other substrates. In addition, this assay gave negative results with other clostridium strains, no cross reactions were observed with other experimental strains like C. tetani, C. botulinum, C. acetobutyricum, Bacillus subtilis, and Escherichia coli. This assay is extramly rapid and provides reliable and reproducible results within one hour of incubation at 37°C.

  12. Loop-mediated isothermal amplification assay for rapid and sensitive detection of sheep pox and goat pox viruses in clinical samples.

    PubMed

    Venkatesan, G; Balamurugan, V; Bhanuprakash, V; Singh, R K; Pandey, A B

    2016-06-01

    A Loop-mediated isothermal amplification (LAMP) assay targeting the highly conserved DNA polymerase gene of capripox virus genome was developed and evaluated for rapid detection of sheep pox and goat pox viruses. The optimized LAMP assay is found specific and sensitive for amplification of target DNA with a diagnostic sensitivity and specificity of 96.6% and 100% respectively compared to quantitative PCR. The detection rate of LAMP, PCR and Q-PCR assays is found to be 81.5%, 67% and 83% respectively. This LAMP assay has the potential for rapid clinical diagnosis and surveillance of sheep pox and goat pox in field diagnostic laboratories. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Detection of nucleophosmin 1 mutations by quantitative real-time polymerase chain reaction versus capillary electrophoresis: a comparative study.

    PubMed

    Barakat, Fareed H; Luthra, Rajyalakshmi; Yin, C Cameron; Barkoh, Bedia A; Hai, Seema; Jamil, Waqar; Bhakta, Yaminiben I; Chen, Su; Medeiros, L Jeffrey; Zuo, Zhuang

    2011-08-01

    Nucleophosmin 1 (NPM1) is the most commonly mutated gene in acute myeloid leukemia. Detection of NPM1 mutations is useful for stratifying patients for therapy, predicting prognosis, and assessing for minimal residual disease. Several methods have been developed to rapidly detect NPM1 mutations in genomic DNA and/or messenger RNA specimens. To directly compare a quantitative real-time polymerase chain reaction (qPCR) assay with a widely used capillary electrophoresis assay for detecting NPM1 mutations. We adopted and modified a qPCR assay designed to detect the 6 most common NPM1 mutations and performed the assay in parallel with capillary electrophoresis assay in 207 bone marrow aspirate or peripheral blood samples from patients with a range of hematolymphoid neoplasms. The qPCR assay demonstrated a higher analytical sensitivity than the capillary electrophoresis 1/1000 versus 1/40, respectively. The capillary electrophoresis assay generated 10 equivocal results that needed to be repeated, whereas the qPCR assay generated only 1 equivocal result. After test conditions were optimized, the qPCR and capillary electrophoresis methods produced 100% concordant results, 85 positive and 122 negative. Given the higher analytical sensitivity and specificity of the qPCR assay, that assay is less likely to generate equivocal results than the capillary electrophoresis assay. Moreover, the qPCR assay is quantitative, faster, cheaper, less prone to contamination, and well suited for monitoring minimal residual disease.

  14. The development of loop-mediated isothermal amplification targeting alpha-tubulin DNA for the rapid detection of Plasmodium vivax.

    PubMed

    Dinzouna-Boutamba, Sylvatrie-Danne; Yang, Hye-Won; Joo, So-Young; Jeong, Sookwan; Na, Byoung-Kuk; Inoue, Noboru; Lee, Won-Ki; Kong, Hyun-Hee; Chung, Dong-Il; Goo, Youn-Kyoung; Hong, Yeonchul

    2014-06-30

    Malaria that is caused by Plasmodium vivax is the most widely distributed human malaria. Its recent resurgence in many parts of the world, including the Republic of Korea (ROK), emphasizes the importance of improved access to the early and accurate detection of P. vivax to reduce disease burden. In this study, a rapid and efficient loop-mediated isothermal amplification (LAMP)-based method was developed and validated using blood samples from malaria-suspected patients. A LAMP assay targeting the α-tubulin gene for the detection of P. vivax was developed with six primers that recognize different regions of the target gene. The diagnostic performance of the α-tubulin LAMP assay was compared to three other tests: microscopic examinations, rapid diagnostic tests (RDTs), and nested polymerase chain reactions (PCRs) using 177 whole blood specimens obtained from ROK military personnel from May to December 2011. The α-tubulin LAMP assay was highly sensitive with a detection limit of 100 copies of P. vivax α-tubulin gene per reaction within 50 min. It specifically amplified the target gene only from P. vivax. Validation of the α-tubulin LAMP assay showed that the assay had the highest sensitivity (P < 0.001 versus microscopy; P = 0.0023 versus RDT) when nested PCR was used as the gold standard and better agreement (concordance: 94.9%, kappa value: 0.865) with nested PCR than RDT and microscopy. A Receiver Operation Characteristics analysis showed that the diagnostic accuracy of the α-tubulin LAMP assay for vivax malaria was higher (Area Under Curve = 0.908) than RDT and microscopy. This study showed that the P. vivax α-tubulin LAMP assay, which can be used to diagnose early infections of vivax malaria, is an alternative molecular diagnostic tool and a point-of-care test that may help to prevent transmission in endemic areas.

  15. Development and validation of an automated enzyme assay for paracetamol (acetaminophen).

    PubMed

    Morris, H C; Overton, P D; Ramsay, J R; Campbell, R S; Hammond, P M; Atkinson, T; Price, C P

    1990-02-28

    A rapid, enzymatic assay for serum or plasma paracetamol has been developed with the potential for adaptation to a wide range of clinical analysers. The method involves the action of an amidase enzyme to produce 4-aminophenol from paracetamol, which in turn reacts with 8-hydroxyquinoline in the presence of manganese ions to form a blue dye. Two stable reagents are used and excellent precision is achieved over the drug concentration range 0-2.5 mmol/l. The method, which is complete within 6 min, has been validated using a Monarch centrifugal analyser and shows no significant interference from endogenous serum compounds, drugs or paracetamol metabolites.

  16. Evaluation of a Rapid Fecal PCR Test for Detection of Mycobacterium avium subsp. paratuberculosis in Dairy Cattle▿

    PubMed Central

    Wells, Scott J.; Collins, Michael T.; Faaberg, Kay S.; Wees, Carrie; Tavornpanich, Saraya; Petrini, Kristine R.; Collins, James E.; Cernicchiaro, Natalia; Whitlock, Robert H.

    2006-01-01

    A high-throughput TaqMan PCR assay for detection of bovine paratuberculosis was evaluated by using fecal samples from 1,808 dairy cattle in seven naturally infected herds and 347 dairy cattle in seven herds considered free of paratuberculosis. Fecal, blood, and milk samples were submitted to laboratories where the PCR-based assay, three different fecal culture procedures for Mycobacterium avium subsp. paratuberculosis (centrifugation, sedimentation, and the BACTEC filter concentration method), two serologic enzyme-linked immunosorbent assays (ELISAs), and one milk ELISA were performed. Results from testing of dairy cattle in herds free of M. avium subsp. paratuberculosis showed that the PCR assay's specificity was 99.7%. Twenty-three percent of the dairy cows that were fecal culture positive by at least one of the three methods were positive by the PCR assay. By Bayesian non-“gold standard” analysis methods, the TaqMan PCR assay had a higher specificity than the serum ELISAs (99.3%; 95% confidence interval [CI] = 98.6 to 99.7%) and a test sensitivity similar to that of the serum ELISAs (29%; 95% CI = 24 to 35%). By classical methods, the estimated relative sensitivity of the fecal PCR assay was 4% for light and moderate fecal shedders (compared to 12 to 13% for the ELISAs) and 76% for heavy fecal shedders (compared to 67% for the milk ELISA). The PCR assay has higher sensitivity for detection of heavy fecal shedders than the evaluated milk ELISA but lower sensitivity than a serum or milk ELISA for detection of light and moderate fecal shedders. This assay can be used as a quick test for detection of cattle with heavy fecal shedding, those cattle with the highest risk of transmitting infection to susceptible cattle. PMID:16928884

  17. A MODIFIED LOW COST COLOURIMETRIC METHOD FOR PARACETAMOL (ACETAMINOPHEN) MEASUREMENT IN PLASMA

    PubMed Central

    Shihana, Fathima; Dissanayake, Dhammika Menike; Dargan, Paul Ivor; Dawson, Andrew Hamilton

    2011-01-01

    Background Despite a significant increase in the number of patients with paracetamol poisoning in the developing world, plasma paracetamol assays are not widely available. The purpose of this study was to assess a low cost modified colorimetric paracetamol assay that has the potential to be performed in small laboratories with restricted resources. Methods The paracetamol assay used in this study was based on the Glynn and Kendal colorimetric method with a few modifications in order to decrease the production of nitrous gas and thereby reduce infrastructure costs. Preliminary validation studies were performed using spiked aqueous samples with known concentrations of paracetamol. Subsequently, the results from the colorimetric method for 114 stored clinical samples from patients with paracetamol poisoning were compared with those from the current gold-standard high-performance liquid chromatography (HPLC) method. A prospective survey, assessing the clinical use of the paracetamol assay, was performed on all patients with paracetamol poisoning attending the Peradeniya General Hospital, Sri Lanka over a ten-month period. Results The recovery study showed an excellent correlation (r2 >0.998) for paracetamol concentrations from 25- 400 mg/l. The final yellow colour was stable for at least 10 minutes at room temperature. There was also excellent correlation with the HPLC method (r2=0.9758). In the clinical cohort study, use of the antidote N-acetylcysteine was avoided in over a third of patients who had a plasma paracetamol concentration measured. The cost of consumables used per assay was $0.50 (US). Conclusions This colorimetric paracetamol assay is reliable and accurate and can be performed rapidly, easily and economically. Use of this assay in resource poor clinical settings has the potential to have a significant clinical and economic impact on the management of paracetamol poisoning. PMID:20095813

  18. Electrochemical detection of microRNAs via gap hybridization assay.

    PubMed

    Pöhlmann, Christopher; Sprinzl, Mathias

    2010-06-01

    MicroRNAs have recently been associated with cancer development by acting as tumor suppressors or oncogenes and could therefore be applied as molecular markers for early diagnosis of cancer. In this work, we established a rapid, selective, and sensitive gap hybridization assay for detection of mature microRNAs based on four components DNA/RNA hybridization and electrochemical detection using esterase 2-oligodeoxynucleotide conjugates. Complementary binding of microRNA to a gap built of capture and detector oligodeoxynucleotide, the reporter enzyme is brought to the vicinity of the electrode and produces enzymatically an electrochemical signal. In the absence of microRNA, the gap between capture and detector oligodeoxynucleotide is not filled, and missing base stacking energy destabilizes the hybridization complex. The gap hybridization assay demonstrates selective detection of miR-16 within a mixture of other miRNAs, including the feasibility of single mismatch discrimination. Applying the biosensor assay, a detection limit of 2 pM or 2 amol of miR-16 was obtained. Using isolated total RNA from human breast adenocarcinoma MCF-7 cells, the assay detected specifically miR-21 and miR-16 in parallel, and higher expression of oncogene miR-21 compared to miR-16 was demonstrated. Including RNA isolation, the gap hybridization assay was developed with a total assay time of 60 min and without the need for reverse transcription PCR amplification of the sample. The characteristics of the assay developed in this work could satisfy the need for rapid and easy methods for early cancer marker detection in clinical diagnostics.

  19. A high-throughput assay for DNA topoisomerases and other enzymes, based on DNA triplex formation.

    PubMed

    Burrell, Matthew R; Burton, Nicolas P; Maxwell, Anthony

    2010-01-01

    We have developed a rapid, high-throughput assay for measuring the catalytic activity (DNA supercoiling or relaxation) of topoisomerase enzymes that is also capable of monitoring the activity of other enzymes that alter the topology of DNA. The assay utilises intermolecular triplex formation to resolve supercoiled and relaxed forms of DNA, the principle being the greater efficiency of a negatively supercoiled plasmid to form an intermolecular triplex with an immobilised oligonucleotide than the relaxed form. The assay provides a number of advantages over the standard gel-based methods, including greater speed of analysis, reduced sample handling, better quantitation and improved reliability and accuracy of output data. The assay is performed in microtitre plates and can be adapted to high-throughput screening of libraries of potential inhibitors of topoisomerases including bacterial DNA gyrase.

  20. Eliminating Size-Associated Diffusion Constraints for Rapid On-Surface Bioassays with Nanoparticle Probes.

    PubMed

    Li, Junwei; Zrazhevskiy, Pavel; Gao, Xiaohu

    2016-02-24

    Nanoparticle probes enable implementation of advanced on-surface assay formats, but impose often underappreciated size-associated constraints, in particular on assay kinetics and sensitivity. The present study highlights substantially slower diffusion-limited assay kinetics due to the rapid development of a nanoprobe depletion layer next to the surface, which static incubation and mixing of bulk solution employed in conventional assay setups often fail to disrupt. In contrast, cyclic solution draining and replenishing yields reaction-limited assay kinetics irrespective of the probe size. Using common surface bioassays, enzyme-linked immunosorbent assays and immunofluorescence, this study shows that this conceptually distinct approach effectively "erases" size-dependent diffusion constraints, providing a straightforward route to rapid on-surface bioassays employing bulky probes and procedures involving multiple labeling cycles, such as multicycle single-cell molecular profiling. For proof-of-concept, the study demonstrates that the assay time can be shortened from hours to minutes with the same probe concentration and, at a typical incubation time, comparable target labeling can be achieved with up to eight times lower nanoprobe concentration. The findings are expected to enable realization of novel assay formats and stimulate development of rapid on-surface bioassays with nanoparticle probes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Top