Science.gov

Sample records for rapid radiometric method

  1. Radiometric Methods for Rapid Diagnosis of Viral Infection.

    DTIC Science & Technology

    1975-11-01

    4, 6, 24, 48, and 72 hours postinfection, infection time beginning when the 14C-labeled medium was added. Nucleic acid sT, thesis system. Stationary...coccus epidermidis, Pseudomonas aeruginosa, and Acinetobacter caloaceticus var. anitratus) had no effect on the DNA synthesis of HSV-1 infected or...7 UNCLASS 41 RADIOMETRIC METHODS FOR RAPID DIAGNIS F VIRA ~ /fl INFECTION (U) JOHNS HOPKINS UNIV BALTIMORE MDUNC . IFEDH N WAG ER FT AL. NOV 75

  2. Radiometric method for the rapid detection of Leptospira organisms

    SciTech Connect

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-02-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with /sup 14/C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques.

  3. Rapid radiometric methods to detect and differentiate Mycobacterium tuberculosis/M. bovis from other mycobacterial species

    SciTech Connect

    Siddiqi, S.H.; Hwangbo, C.C.; Silcox, V.; Good, R.C.; Snider, D.E. Jr.; Middlebrook, G.

    1984-10-01

    Rapid methods for the differentiation of Mycobacterium tuberculosis/M. bovis (TB complex) from other mycobacteria (MOTT bacilli) were developed and evaluated in a three-phase study. In the first phase, techniques for identification of Mycobacterium species were developed by using radiometric technology and BACTEC Middlebrook 7H12 liquid medium. Based on /sup 14/CO/sub 2/ evolution, characteristic growth patterns were established for 13 commonly encountered mycobacterial species. Mycobacteria belonging to the TB complex were differentiated from other mycobacteria by cellular morphology and rate of /sup 14/CO/sub 2/ evolution. For further differentiation, radiometric tests for niacin production and inhibition by Q-nitro-alpha-acetyl amino-beta-hydroxy-propiophenone (NAP) were developed. In the second phase, 100 coded specimens on Lowenstein-Jensen medium were identified as members of the TB complex, MOTT bacilli, bacteria other than mycobacteria, or ''no viable organisms'' within 3 to 12 (average 6.4) days of receipt from the Centers for Disease Control. Isolation and identification of mycobacteria from 20 simulated sputum specimens were carried out in phase III. Out of 20 sputum specimens, 16 contained culturable mycobacteria, and all of the positives were detected by the BACTEC method in an average of 7.3 days. The positive mycobacterial cultures were isolated and identified as TB complex or MOTT bacilli in an average of 12.8 days. The radiometric NAP test was found to be highly sensitive and specific for a rapid identification of TB complex, whereas the radiometric niacin test was found to have some inherent problems. Radiometric BACTEC and conventional methodologies were in complete agreement in Phase II as well as in Phase III.

  4. Rapid radiometric serum test for antibiotic activity.

    PubMed

    D'Antonio, R G; Camargo, E E; Gedra, T; Wagner, H N; Charache, P

    1982-02-01

    We have developed a 4-h radiometric method to predict the bacteriostatic endpoint by the tube dilution method. A mixture of [U-14C] glucose, [guanido-14C] arginine, and [U-14C] glycine was used to monitor the metabolic activity of both gram-positive and gram-negative organisms. The tube dilution method and the radiometric method were performed in parallel in 18 clinical serum samples. In the radiometric method, the samples were separated into control and test portions and serially diluted in Mueller-Hinton broth. Antibiotics in the control portion were inactivated with penicillinase or cellulose phosphate or both. The radioactive mixture and a 1-h culture of the patient's infecting organisms were added to all vials. The 14CO2 production after a 3-h incubation at 37 degrees C was measured, and the percent inhibition was determined for each vial by using the control vials as reference (no inhibition). Radiometric dose-response curves obtained for all samples showed that, by using a greater than or equal to 60% inhibition at 1:8 dilution, the radiometric method correctly predicted the outcome of the tube dilution method in 16 or 18 clinical samples.

  5. Rapid radiometric susceptibility testing of Mycobacterium tuberculosis.

    PubMed

    Kertcher, J A; Chen, M F; Charache, P; Hwangbo, C C; Camargo, E E; McIntyre, P A; Wagner, H N

    1978-04-01

    A 48-hour radiometric test for determining the drug susceptibility of Mycobacterium tuberculosis has been developed. The test is based on the measurement of 14CO2 produced by the oxidation of formate labeled with carbon-14. The test system uses 5 X 10(7) organisms in 1 ml of Middlebrook 7H9 medium plus albumin-dextrose-catalase enrichment and 1 muCi of [14C]formate. The 14CO2 produced is measured in an ionization chamber at 24-, 48-, and 72-hour intervals, with and without the addition of antituberculous drugs. Isoniazid, streptomycin, rifampin, and ethambutol were each tested at 3 concentrations by the radiometric method and the reference (agar dilution) method. Six standard strains and 21 patient isolates were compared by both methods. Production of 14CO2 was quantitatively decreased in the presence of drugs that inhibit the organism. The radiometric method requires 2 days; the agar dilution, 14 to 21 days.

  6. RapidEye constellation relative radiometric accuracy measurement using lunar images

    NASA Astrophysics Data System (ADS)

    Steyn, Joe; Tyc, George; Beckett, Keith; Hashida, Yoshi

    2009-09-01

    The RapidEye constellation includes five identical satellites in Low Earth Orbit (LEO). Each satellite has a 5-band (blue, green, red, red-edge and near infrared (NIR)) multispectral imager at 6.5m GSD. A three-axes attitude control system allows pointing the imager of each satellite at the Moon during lunations. It is therefore possible to image the Moon from near identical viewing geometry within a span of 80 minutes with each one of the imagers. Comparing the radiometrically corrected images obtained from each band and each satellite allows a near instantaneous relative radiometric accuracy measurement and determination of relative gain changes between the five imagers. A more traditional terrestrial vicarious radiometric calibration program has also been completed by MDA on RapidEye. The two components of this program provide for spatial radiometric calibration ensuring that detector-to-detector response remains flat, while a temporal radiometric calibration approach has accumulated images of specific dry dessert calibration sites. These images are used to measure the constellation relative radiometric response and make on-ground gain and offset adjustments in order to maintain the relative accuracy of the constellation within +/-2.5%. A quantitative comparison between the gain changes measured by the lunar method and the terrestrial temporal radiometric calibration method is performed and will be presented.

  7. Detection of coliform organisms in drinking water by radiometric method.

    PubMed

    Khurshid, S J; Bibi, S

    1991-07-01

    The radiometric method has been used for detection of coliform bacteria in water. The method is based on measuring the released metabolic 14CO2 from 14C-lactose in growth media containing coliform organisms incubated at 37 degrees C under continuous shaking. This rapid and sensitive radiometric method permits the detection of even single coliform organisms within 6 hours of incubation. Using this automated method, a total of 102 samples (in duplicate) collected from different areas in and around Rawalpindi and Islamabad were assessed for coliform bacteria. Of these 102 samples, 50 were tap water samples, 40 from wells and 6 each were from Rawal and Simly dams. About 47% and 67% tap water samples, while 62% and 74% well water samples were found unsatisfactory from around Islamabad and Rawalpindi areas, respectively. About 83% and 66% water samples from Rawal dam and Simly dam respectively were found to be unsatisfactory.

  8. Characterization of Mycobacterium paratuberculosis by gas-liquid and thin-layer chromatography and rapid demonstration of mycobactin dependence using radiometric methods

    SciTech Connect

    Damato, J.J.; Knisley, C.; Collins, M.T.

    1987-12-01

    Thirty-six Mycobacterium paratuberculosis isolates of bovine, caprine, and ovine origins were evaluated by using gas-liquid chromatography (GLC), thin-layer chromatography (TLC), and BACTEC 7H12 Middlebrook TB medium in an effort to more rapidly differentiate this group of organisms from other mycobacteria. Bacterial suspensions (0.1 ml) were inoculated by syringe into 7H12 broth containing 2 micrograms of mycobactin P per ml and control broth without mycobactin P. Cultures were incubated at 37/sup 0/C and read daily with a BACTEC Model 301. After 8 days of incubation, the growth index readings for the test broths containing mycobactin P were twice those of the control broths without mycobactin P. Sixty-five isolates of mycobacteria other than M. paratuberculosis were also examined. No difference was noted between the growth index readings of control and mycobactin-containing broths. Except for Mycobacterium avium-Mycobacterium intracellulare, TLC studies differentiated M. paratuberculosis from the other mycobacterial species tested. The GLC data reveal that all M. paratuberculosis isolates had a distinctive peak (14A) which was not found among M. avium-M. intracellulare complex organisms. These data indicate that 7H12 radiometric broth was able to rapidly demonstrate the mycobactin dependence of M. paratuberculosis and GLC and TLC procedures were capable of rapidly differentiating this organism from the other mycobacteria studied.

  9. Rapid recovery of mycobacteria from clinical specimens using automated radiometric technic

    SciTech Connect

    Park, C.H.; Hixon, D.L.; Ferguson, C.B.; Hall, S.L.; Risheim, C.C.; Cook, C.B.

    1984-03-01

    Automated radiometric technic (BACTEC Johnston Laboratories, Towson, MD) was compared with conventional mycobacterial culture procedure (Lowenstein-Jensen plus Gruft modification of Lowenstein-Jensen) in this study of 1,000 clinical specimens. In addition, 8-azaguanine inhibition was tested by radiometric technic as a rapid procedure for the differentiation of Mycobacterium tuberculosis from other mycobacterial species. A total of 59 mycobacteria was recovered. Of 28 clinically significant isolates (M. tuberculosis, M. kansasii, M. avium, M. fortuitum), the BACTEC system detected 26 (93%). Conventional methods recovered 23 (82%). The BACTEC system required an average of seven days to recover M. tuberculosis from smear-positive specimens compared with 18 days required by Lowenstein-Jensen or Gruft slants. From smear-negative specimens, the BACTEC detected M. tuberculosis in an average of 20 days versus 28 days by conventional procedure. All 20 isolates of M. tuberculosis were inhibited by 8-azaguanine, whereas 39 isolates of mycobacteria other than M. tuberculosis were not inhibited. The BACTEC system accomplishes more rapid recovery of mycobacteria and provides a higher yield than conventional methods.

  10. MODIS Radiometric Calibration Program, Methods and Results

    NASA Technical Reports Server (NTRS)

    Xiong, Xiaoxiong; Guenther, Bruce; Angal, Amit; Barnes, William; Salomonson, Vincent; Sun, Junqiang; Wenny, Brian

    2012-01-01

    As a key instrument for NASA s Earth Observing System (EOS), the Moderate Resolution Imaging Spectroradiometer (MODIS) has made significant contributions to the remote sensing community with its unprecedented amount of data products continuously generated from its observations and freely distributed to users worldwide. MODIS observations, covering spectral regions from visible (VIS) to long-wave infrared (LWIR), have enabled a broad range of research activities and applications for studies of the earth s interactive system of land, oceans, and atmosphere. In addition to extensive pre-launch measurements, developed to characterize sensor performance, MODIS carries a set of on-board calibrators (OBC) that can be used to track on-orbit changes of various sensor characteristics. Most importantly, dedicated and continuous calibration efforts have been made to maintain sensor data quality. This paper provides an overview of the MODIS calibration program, on-orbit calibration activities, methods, and performance. Key calibration results and lessons learned from the MODIS calibration effort are also presented in this paper.

  11. Determination of in vitro susceptibility of Mycobacterium tuberculosis to cephalosporins by radiometric and conventional methods

    SciTech Connect

    Heifets, L.B.; Iseman, M.D.; Cook, J.L.; Lindholm-Levy, P.J.; Drupa, I.

    1985-01-01

    Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlation among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis.

  12. Determination of in vitro susceptibility of Mycobacterium tuberculosis to cephalosporins by radiometric and conventional methods.

    PubMed Central

    Heifets, L B; Iseman, M D; Cook, J L; Lindholm-Levy, P J; Drupa, I

    1985-01-01

    Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlation among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis. PMID:3920957

  13. Recovery and susceptibility testing of Mycobacterium tuberculosis from extrapulmonary specimens by the BACTEC radiometric method.

    PubMed Central

    Fadda, G; Roe, S L

    1984-01-01

    This study was carried out to evaluate the sensitivity and rapidity of the BACTEC radiometric techniques for isolation and susceptibility testing of mycobacteria from extrapulmonary specimens. Concentrated specimens of urine, pleural fluid, and blood as well as other extrapulmonary specimens were processed for the recovery of mycobacteria and for drug susceptibility testing, employing conventional and BACTEC radiometric methods. Out of 483 specimens processed, 20 were found to be positive for Mycobacterium tuberculosis on the conventional Lowenstein -Jensen medium, and 19 were found to be positive in the BACTEC 7H12 medium. Average recovery times were 22.5 days for the conventional method and 10.9 days for the BACTEC method. When isolated cultures were tested for susceptibility to streptomycin, isoniazid, rifampin, and ethambutol, results were reported at an average time of 22 and 5.4 days for the conventional and BACTEC methods, respectively, with good correlation. PMID:6429193

  14. Site characterization for calibration of radiometric sensors using vicarious method

    NASA Astrophysics Data System (ADS)

    Parihar, Shailesh; Rathore, L. S.; Mohapatra, M.; Sharma, A. K.; Mitra, A. K.; Bhatla, R.; Singh, R. S.; Desai, Yogdeep; Srivastava, Shailendra S.

    2016-05-01

    Radiometric performances of earth observation satellite/sensors vary from ground pre-launch calibration campaign to post launch period extended to lifetime of the satellite due to launching vibrations. Therefore calibration is carried out worldwide through various methods throughout satellite lifetime. In India Indian Space Research Organization (ISRO) calibrates the sensor of Resourcesat-2 satellite by vicarious method. One of these vicarious calibration methods is the reflectance-based approach that is applied in this study for radiometric calibration of sensors on-board Resouresat-2 satellite. The results of ground-based measurement of atmospheric conditions and surface reflectance are made at Bap, Rajasthan Calibration/Validation (Cal/Val) site. Cal/Val observations at site were carried out with hyper-spectral Spectroradiometer covering spectral range of 350nm- 2500nm for radiometric characterization of the site. The Sunphotometer/Ozonometer for measuring the atmospheric parameters has also been used. The calibrated radiance is converted to absolute at-sensor spectral reflectance and Top-Of-Atmosphere (TOA) radiance. TOA radiance was computed using radiative transfer model `Second simulation of the satellite signal in the solar spectrum' (6S), which can accurately simulate the problems introduced by the presence of the atmosphere along the path from Sun to target (surface) to Sensor. The methodology for band averaged reflectance retrieval and spectral reflectance fitting process are described. Then the spectral reflectance and atmospheric parameters are put into 6S code to predict TOA radiance which compare with Resourcesat-2 radiance. Spectral signature and its reflectance ratio indicate the uniformity of the site. Thus the study proves that the selected site is suitable for vicarious calibration of sensor of Resourcesat-2. Further the study demonstrates the procedure for similar exercise for site selection for Cal/Val analysis of other satellite over India

  15. A radiometric method for predicting effectiveness of chemotherapeutic agents in murine leprosy.

    PubMed

    Camargo, E E; Larson, S M; Tepper, B S; Wagner, H N

    1975-01-01

    A simple radiometric method has been developed for evaluating the effect of drugs on the metabolism of M. lepraemurium. The method is based on the measurement of the 14CO2 produced through bacterial metabolism of acetate-U-14C. Seventeen drugs were tested: bacitracin, cephaloridine, chloramphenicol, cycloserine, dactinomycin, DDS, ethionamide, INH, kanamycin, methenamine mandelate, nitrofurantoin, oxacillin, polymyxin B, rifampicin, streptomycin, sulfadimethoxine and vancomycin. The drugs which caused most marked inhibition were chloramphenicol, INH, ethionamide and nitrofurantoin in order of increasing effectiveness. The radiometric study which is completed in 15 days permits direct study of the drug effect on the metabolism of M. lepraemurium and a more rapid screening of antileprosy drugs than has previously been possible. Currently, these observations are being extended to studies of the structure-activity relationships of antileprosy drugs and the metabolism and drug susceptibility of M. leprae in vitro.

  16. Radiometric and geometric assessment of data from the RapidEye constellation of satellites

    USGS Publications Warehouse

    Chander, Gyanesh; Haque, Md. Obaidul; Sampath, Aparajithan; Brunn, A.; Trosset, G.; Hoffmann, D.; Roloff, S.; Thiele, M.; Anderson, C.

    2013-01-01

    To monitor land surface processes over a wide range of temporal and spatial scales, it is critical to have coordinated observations of the Earth's surface using imagery acquired from multiple spaceborne imaging sensors. The RapidEye (RE) satellite constellation acquires high-resolution satellite images covering the entire globe within a very short period of time by sensors identical in construction and cross-calibrated to each other. To evaluate the RE high-resolution Multi-spectral Imager (MSI) sensor capabilities, a cross-comparison between the RE constellation of sensors was performed first using image statistics based on large common areas observed over pseudo-invariant calibration sites (PICS) by the sensors and, second, by comparing the on-orbit radiometric calibration temporal trending over a large number of calibration sites. For any spectral band, the individual responses measured by the five satellites of the RE constellation were found to differ <2–3% from the average constellation response depending on the method used for evaluation. Geometric assessment was also performed to study the positional accuracy and relative band-to-band (B2B) alignment of the image data sets. The position accuracy was assessed by comparing the RE imagery against high-resolution aerial imagery, while the B2B characterization was performed by registering each band against every other band to ensure that the proper band alignment is provided for an image product. The B2B results indicate that the internal alignments of these five RE bands are in agreement, with bands typically registered to within 0.25 pixels of each other or better.

  17. Improved Radiometric Based Method for Suppressing Impulse Noise from Corrupted Images

    NASA Astrophysics Data System (ADS)

    Wu, Changcheng; Zhao, Chunyu; Chen, Dayue

    A novel filter is introduced in this paper to improve the ability of radiometric based method on suppressing impulse noise. Firstly, a new method is introduced to design the impulsive weight by measuring how impulsive a pixel is. Then, the impulsive weight is combined with the radiometric weight to obtain the evaluated values on each pixel in the whole corrupted image. The impulsive weight is mainly designed to suppress the impulse noise, while the radiometric weight is mainly designed to protect the noise-free pixel. Extensive experiments demonstrate that the proposed algorithm can perform much better than other filters in terms of the quantitative and qualitative aspects.

  18. Radiometric method for determining solubility of organic solvents in water

    SciTech Connect

    Lo, J.M.; Tseng, C.L.; Yang, J.Y.

    1986-06-01

    Cobalt-60 labeled cobalt(III) pyrrolidinecarbodithioate (/sup 60/Co(PDC)/sub 3/) has a peculiar stability during storage in organic solvent and when its organic solution is shaken with an aqueous solution containing different acids or ions. Using these characteristics, the authors have attempted to use /sup 60/Co(PDC)/sub 3/ as a radioagent for determining solubilities of various organic solvents in water. The radioagent was first dissolved in the organic solvent under investigation before pure water was added. The solution mixture was shaken vigorously in order to let the organic phase contact with water sufficiently. Some of the organic solvent would dissolve in water after shaking, resulting in volume reduction of the organic phase. However, the radioagent was found not to accompany the organic solvent molecules going into water; i.e., all the radioactivity of /sup 60/Co(PDC)/sub 3/ would be retained in the organic phase. Solubility of the organic solvent in water therefore can be calculated from the value of the volume change of the organic phase divided by the water volume. Direct measurement of a small change in volume of organic phase with high accuracy is generally very difficult; alternatively, the authors have measured the specific activities of /sup 60/Co(PDC)/sub 3/ (cpm/mL) in the original and the final organic solutions, and the counting results were used to estimate the decrease in volume of the organic phase. Several commonly used organic solvents were selected to test the applicability of the proposed radiometric method. The solubilities of the organic solvents selected for this study range from very small values (10/sup -4/) to relatively large values (10/sup -2/), 6 references, 1 table.

  19. Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods

    SciTech Connect

    Siddiqi, S.H.; Hawkins, J.E.; Laszlo, A.

    1985-12-01

    A total of 224 recent isolates of Mycobacterium tuberculosis from 163 patients selected to have multidrug resistance were tested against streptomycin (SM), isoniazid, rifampin, and ethambutol (EMB) by the rapid radiometric BACTEC method and two conventional proportion methods: the World Health Organization (WHO) method, using Lowenstein-Jensen medium; and the Veterans Administration reference laboratory for mycobacteria (VA) method, using Middlebrook 7H10 agar medium. The results were compared, focusing on the concentrations of the drugs in all three methods. Among the four drugs tested, most of the discrepancies in measured activity were observed with SM and EMB, generally because of differences in the drug concentrations used by the three methods. A 4-micrograms amount of SM in the BACTEC method was found to be slightly less active than 10 micrograms in the VA method and significantly more active than 4 micrograms of dihydrostreptomycin in the WHO method. With EMB, 2.5 micrograms in BACTEC was similar to 5 micrograms in the VA method and 2 micrograms in the WHO method, while 10 micrograms in the BACTEC method was found to be more active than 10 and 2 micrograms in the VA and WHO methods, respectively. To attain close agreement, drug concentrations used in the BACTEC method should be carefully selected when a comparison is to be made with any conventional method employed in a laboratory. Standardization of in vitro susceptibility testing is greatly needed to achieve uniformity among the test methods used to evaluate tuberculosis therapeutics.

  20. Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods.

    PubMed Central

    Siddiqi, S H; Hawkins, J E; Laszlo, A

    1985-01-01

    A total of 224 recent isolates of Mycobacterium tuberculosis from 163 patients selected to have multidrug resistance were tested against streptomycin (SM), isoniazid, rifampin, and ethambutol (EMB) by the rapid radiometric BACTEC method and two conventional proportion methods: the World Health Organization (WHO) method, using Lowenstein-Jensen medium; and the Veterans Administration reference laboratory for mycobacteria (VA) method, using Middlebrook 7H10 agar medium. The results were compared, focusing on the concentrations of the drugs in all three methods. Among the four drugs tested, most of the discrepancies in measured activity were observed with SM and EMB, generally because of differences in the drug concentrations used by the three methods. A 4-micrograms amount of SM in the BACTEC method was found to be slightly less active than 10 micrograms in the VA method and significantly more active than 4 micrograms of dihydrostreptomycin in the WHO method. With EMB, 2.5 micrograms in BACTEC was similar to 5 micrograms in the VA method and 2 micrograms in the WHO method, while 10 micrograms in the BACTEC method was found to be more active than 10 and 2 micrograms in the VA and WHO methods, respectively. To attain close agreement, drug concentrations used in the BACTEC method should be carefully selected when a comparison is to be made with any conventional method employed in a laboratory. Standardization of in vitro susceptibility testing is greatly needed to achieve uniformity among the test methods used to evaluate tuberculosis therapeutics. PMID:3934209

  1. Experimental methods of indoor millimeter-wave radiometric imaging for personnel concealed contraband detection

    NASA Astrophysics Data System (ADS)

    Hu, Taiyang; Xiao, Zelong; Li, Hao; Lv, Rongchuan; Lu, Xuan

    2014-11-01

    The increasingly emerging terrorism attacks and violence crimes around the world have posed severe threats to public security, so carrying out relevant research on advanced experimental methods of personnel concealed contraband detection is crucial and meaningful. All of the advantages of imaging covertly, avoidance of interference with other systems, intrinsic property of being safe to persons under screening , and the superior ability of imaging through natural or manmade obscurants, have significantly combined to enable millimeter-wave (MMW) radiometric imaging to offer great potential in personnel concealed contraband detection. Based upon the current research status of MMW radiometric imaging and urgent demands of personnel security screening, this paper mainly focuses on the experimental methods of indoor MMW radiometric imaging. The reverse radiation noise resulting from super-heterodyne receivers seriously affects the image experiments carried out at short range, so both the generation mechanism and reducing methods of this noise are investigated. Then, the benefit of sky illumination no longer exists for the indoor radiometric imaging, and this leads to the decrease in radiometric temperature contrast between target and background. In order to enhance the radiometric temperature contrast for improving indoor imaging performance, the noise illumination technique is adopted in the indoor imaging scenario. In addition, the speed and accuracy of concealed contraband detection from acquired MMW radiometric images are usually restricted to the deficiencies in traditional artificial interpretation by security inspectors, thus an automatic recognition and location algorithm by integrating improved Fuzzy C-means clustering with moment invariants is put forward. A series of original results are also presented to demonstrate the significance and validity of these methods.

  2. Comparison of diverse methods for the correction of atmospheric effects on LANDSAT and SKYLAB images. [radiometric correction in Brazil

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Camara, G.; Dias, L. A. V.; Mascarenhas, N. D. D.; Desouza, R. C. M.; Pereira, A. E. C.

    1982-01-01

    Earth's atmosphere reduces a sensors ability in currently discriminating targets. Using radiometric correction to reduce the atmospheric effects may improve considerably the performance of an automatic image interpreter. Several methods for radiometric correction from the open literature are compared leading to the development of an atmospheric correction system.

  3. Direct antimicrobial drug susceptibility testing of Mycobacterium tuberculosis by the radiometric method

    SciTech Connect

    Libonati, J.P.; Stager, C.E.; Davis, J.R.; Siddiqi, S.H.

    1988-05-01

    Direct-drug-susceptibility tests were performed on clinical specimens positive for acid-fast bacilli by either Ziehl-Neelsen or fluorochrome staining. The results of conventional agar dilution and a modified radiometric (BACTEC) method were compared. A total of 580 smear-positive specimens were tested by the BACTEC method at three separate sites. Three hundred and seventy-seven of these were culture positive for M. tuberculosis, and 343 (91%) yielded acceptable direct-susceptibility-test results. We used the conventional method to determine that 343 of 519 smear-positive specimens were culture positive for M. tuberculosis, and 212 (62%) produced acceptable results within 3 wks. Conventional results were reported in 3-4 wks, while the time required to obtain results with the BACTEC method ranged from 5 to 21 days (average 11.5 days). Results indicate that the radiometric method provides reportable results more frequently with time savings as compared to the conventional method.

  4. Radiometric Methods for Rapid Diagnosis of Viral Infection.

    DTIC Science & Technology

    2014-09-26

    Miller G: Assay for Epstein - Barr virus based on stimulation of DNA synthesis in mixed leukocytes from human umbilical cord blood. J Virol 15: 1065...Activation of Epstein - Barr virus by 5-bromodeoxyuridine in " virus -free" human cells. Proc Natl Acad Sci USA 69: 83-85, 1972. 24. LeMevel BP, Wells SA...Thus, there are viruses , such as West Nile virus , which multiply in the cell culture, but do not produce any cytopathic effect. Our radlometric technique

  5. Radiometric reference for weak radiations: comparison of methods

    NASA Astrophysics Data System (ADS)

    Ghazi-Bellouati, A.; Razet, A.; Bastie, J.; Himbert, M. E.; Degiovanni, I. P.; Castelletto, S.; Rastello, M. L.

    2005-08-01

    The parametric down conversion of photons generated in a non-linear crystal gives rise to two correlated photons. When associated with a system of coincidence counting, this phenomenon allows one to measure the quantum efficiencies of detectors working at a normal rate of photon counting, without the need for reference sources or detectors. At the Institut National de Métrologie (INM) (France), this method was implemented with the aim of developing a new standard detector for the absolute measurement of very weak radiation. The validation of this method is presented from an international comparison between the laboratories of the INM (France) and the Istituto Elettrotecnico Nazionale Galileo Ferraris (IENGF) (Italy) and from a comparison of methods at INM using the French national standard detector, the cryogenic radiometer.

  6. Radiometric Method for the Research on Geomechanical Parameters of Rocks

    NASA Astrophysics Data System (ADS)

    Bonczyk, Michał; Wysocka, Małgorzata; Bukowska, Mirosława; Michalik, Bogusław; Prusek, Stanisław; Wadas, Mariusz

    2017-03-01

    Tests aimed to verify whether there is a correlation between the basic parameters characterizing the mechanical properties of rocks with the properties of ionizing radiation scattered by rocks were performed as part of the research. The positive correlation between the two examined properties would provide the basis for the development of a new method of rock testing using radiation sources or devices generating ionizing radiation. The method could be applied to carry out research in underground boreholes to determine the mechanical properties of the rock mass in situ. The study allowed the verification of the adopted assumptions for the proposed method. The verification was based on the correlation analysis of absorption coefficients of the ionizing radiation of rocks from the Upper Silesian Coal Basin with the results of the research on mechanical and physical properties.

  7. Radiometric method for pyrazinamide susceptibility testing of Mycobacterium tuberculosis in egg-yolk-enriched BACTEC 12A medium

    SciTech Connect

    Woodley, C.L.; Smithwick, R.W.

    1988-01-01

    A radiometric method for testing the susceptibility of Mycobacterium tuberculosis to pyrazinamide in egg-yolk-enriched 12A medium (pH 5.5) is described. We obtained 100% agreement between the 7H10 agar method with 25 microgram of pyrazinamide per ml and the modified radiometric method with a drug concentration of 50 microgram/ml in tests of 90 clinical isolates.

  8. Radiometric calibration of SPOT 2 HRV - A comparison of three methods

    NASA Technical Reports Server (NTRS)

    Biggar, Stuart F.; Dinguirard, Magdeleine C.; Gellman, David I.; Henry, Patrice; Jackson, Ray D.; Moran, M. S.; Slater, Philip N.

    1991-01-01

    Three methods for determining an absolute radiometric calibration of a spacecraft optical sensor are compared. They are the well-known reflectance-based and radiance-based methods and a new method based on measurements of the ratio of diffuse-to-global irradiance at the ground. The latter will be described in detail and the comparison of the three approaches will be made with reference to the SPOT-2 HRV cameras for a field campaign 1990-06-19 through 1990-06-24 at the White Sands Missile Range in New Mexico.

  9. NASA Radiometric Characterization

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara

    2006-01-01

    This viewgraph presentation reviews the characterization of radiometric data by NASA. The objective was to perform radiometric vicarious calibrations of imagery and compare with vendor-provided calibration coefficients. The approach was to use multiple, well-characterized sites. These sites are widely used by the NASA science community for radiometric characterization of airborne and space borne sensors. Using the data from these sites, the investigators performed independent characterizations with independent teams. Each team has slightly different measurement techniques and data processing methods.

  10. Separation of secondary refractories by type by radioresonance and x-ray radiometric methods

    SciTech Connect

    Baranovskii, N.I.; Rogozina, V.G.; Bortnikova, N.V.; Koronchevskii, A.V.; Trufanov, A.M.; Fedorov, Yu.O.

    1987-11-01

    The investigations on radiometric methods of beneficiation were made on samples of secondary refractories taken at Orsk-Khalilov Metallurgical Combine which were a mixture of aluminosilicate and magnesia (periclase and periclase-chromite) refractory scrap. The change in quality factor of the circuit under the action on it of secondary refractories was measured at a frequency of 13.56 MHz and the results of the measurements are presented. The periclase, periclase-chromite, and aluminosilicate refractory scrap change the quality factor of the circuit differently. On the basis of these investigations it may be concluded that the radioresonance method of separation may be used for separation of refractory scrap by types.

  11. Infrared radiometric technique for rapid quantitative evaluation of heat flux distribution over large areas

    NASA Technical Reports Server (NTRS)

    Glazer, Stuart; Siebes, Georg

    1989-01-01

    This paper describes a novel approach for rapid, quantitative measurement of spatially distributed heat flux incident on a plane. The technique utilizes the spatial temperature distribution on an opaque thin film at the location of interest, as measured by an imaging infrared radiometer. Knowledge of film radiative properties, plus quantitative estimates of convection cooling permit the steady state energy balance at any location on the film sheet to be solved for the incident heat flux. Absolute accuracies on the order of 10-15 percent have been obtained in tests performed in air. The method is particularly useful for evaluation of spatial heat flux uniformity from distributed heat sources over large areas. It has recently been used in several applications at the Jet Propulsion Laboratory, including flux uniformity measurements from large distributed quartz lamp arrays used during thermal vacuum testing of several spacecraft components, and flux mapping of a low power NdYg laser beam.

  12. NASA IKONOS Radiometric Characterization

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Frisbee, Troy; Zanoni, Vicki; Blonski, Slawek; Daehler, Erik; Grant, Brennan; Holekamp, Kara; Ryan, Robert; Sellers, Richard; Smith, Charles

    2002-01-01

    The objective of this program: Perform radiometric vicarious calibrations of IKQNOS imagery and compare with Space Imaging calibration coefficients The approach taken: utilize multiple well-characterized sites which are widely used by the NASA science community for radiometric characterization of airborne and spaceborne sensors; and to Perform independent characterizations with independent teams. Each team has slightly different measurement techniques and data processing methods.

  13. Radiometric method for testing susceptibility of mycobacteria to pyrazinamide in 7H12 broth.

    PubMed Central

    Heifets, L B; Iseman, M D

    1985-01-01

    The test of susceptibility to pyrazinamide requires an acid environment (pH less than or equal to 5.5). This, however, is not favorable to the growth of Mycobacterium tuberculosis, especially in solid agar media. To obviate this difficulty, we developed a testing method with 7H12 broth medium and based on radiometric readings of the growth. The radiometric method employed in this study (BACTEC system) provides an opportunity to detect the dynamics of growth by daily recording of the growth index, which reflects the metabolic activity of the multiplying bacteria. In our technique, M. tuberculosis isolates were initially cultivated at pH 6.8. After logarithmic growth had begun, phosphoric acid solution was added to obtain pH 5.5. When pyrazinamide was added simultaneously with the acid, the growth index of susceptible cultures decreased, whereas it continued to increase in pH 5.5 control vials and in tests with pyrazinamide-resistant strains. PMID:3972987

  14. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    SciTech Connect

    Hovi, T.; Roivainen, M.

    1989-04-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with /sup 51/Cr, (/sup 3/H)leucine, or, preferentially, with (/sup 3/H)uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30/degree/C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well.

  15. Photovoltaics radiometric issues and needs

    SciTech Connect

    Myers, D.R.

    1995-11-01

    This paper presents a summary of issues discussed at the photovoltaic radiometric measurements workshop. Topics included radiometric measurements guides, the need for well-defined goals, documentation, calibration checks, accreditation of testing laboratories and methods, the need for less expensive radiometric instrumentation, data correlations, and quality assurance.

  16. Real-time measurement of camshaft wear in an automotive engine-a radiometric method

    SciTech Connect

    Schneider, E.W.; Blossfeld, D.H.

    1990-01-01

    A radiometric method has been developed for the determination of camshaft wear during engine operation. After a radioactive tracer is induced at the tips of one or more cam lobes by the technique of surface layer activation, calibration procedures are performed to determine the amount of radioactive material remaining versus the depth worn. The decrease in {gamma}-ray intensity measured external to the engine is then directly related to cam lobe wear. By incorporating a high-resolution detector and an internal radioactive standard, measurement accuracy better than {plus}{equals}0.2 {mu}m at 95% confidence has been achieved. Without the requirement of engine disassembly, this method has provided unique measurements of break-in wear and wear as a function of operating conditions. Because this approach requires only low levels of radiation, it has significant potential applications in wear control.

  17. Radiometric macrophage culture assay for rapid evaluation of antileprosy activity of rifampin

    SciTech Connect

    Mittal, A.; Seshadri, P.S.; Prasad, H.K.; Sathish, M.; Nath, I.

    1983-10-01

    The antileprosy effect of rifampin was evaluated by a newly developed rapid in vitro assay wherein 31 human-derived strains and 1 armadillo-derived strain of Mycobacterium leprae were maintained for 2 and 3 weeks, respectively, in murine and human macrophages in the presence of (3H)thymidine. Of these strains, 27 showed significant incorporation of the radiolabel in cultures of live bacilli as compared with control cultures of heat-killed bacilli of the same strain. Consistent and significant inhibition of (3H)thymidine uptake was observed in M. leprae resident cultures with 3 to 200 ng of rifampin per ml as compared with similar cultures without the drug. In general, an increase in percent inhibition was seen from 3 to 20 ng/ml, with marginal increases at 40, 50, and 100 ng/ml. M. leprae strains appear to be remarkably susceptible to this drug in the in vitro assay.

  18. The Relationship between Balancing Reactions and Reaction Lifetimes: A Consideration of the Potassium-Argon Radiometric Method for Dating Minerals

    ERIC Educational Resources Information Center

    Howard, William A.

    2005-01-01

    A detailed examination of a commonly accepted practice in geology offers an example of how to stimulate critical thinking, teaches students how to read reactions, and challenges students to formulate better experiments for determining mineral ages more accurately. A demonstration of a Potassium-Argon radiometric method for dating minerals is…

  19. The Relationship between Balancing Reactions and Reaction Lifetimes: A Consideration of the Potassium-Argon Radiometric Method for Dating Minerals

    ERIC Educational Resources Information Center

    Howard, William A.

    2005-01-01

    A detailed examination of a commonly accepted practice in geology offers an example of how to stimulate critical thinking, teaches students how to read reactions, and challenges students to formulate better experiments for determining mineral ages more accurately. A demonstration of a Potassium-Argon radiometric method for dating minerals is…

  20. Application of a radiometric method for evaluation of loss of salicylic acid during isolation from biologic material.

    PubMed

    Ostrowski, A

    1983-01-01

    A radiometric method for evaluation of loss of salicylic acid in the process of isolation from biologic material is described. According to this study the mean loss during the total process of isolation amounts to 33.59%, the specific values being 19.47% during protein precipitation, 10.68% during extraction, and 3.44% during evaporation of solvent.

  1. In-flight absolute radiometric calibration of MODIS using the irradiance-based method

    NASA Astrophysics Data System (ADS)

    Wei, Wei; Li, Xin; Zhao, Chun-yan; Qiu, Gang-gang; Zheng, Xiao-bing

    2016-10-01

    In order to reduce the calibration uncertainty of the reflectance-based method brought by the assumption of the aerosol model, the irradiance-based method, known as improved reflectance-based method, was proposed. The irradiance-based method is described in this paper. The radiometric calibration field campaign was performed at Dunhuang test site on 27 August, 2014. A hyperspectral irradiance meter (HSIM) developed by Anhui Institute of Optics and Fine Mechanics (AIOFM) was used to measure the diffuse-to-global spectral irradiance ratio. The irradiance-based method and the reflectance-based method were performed to calibrate the first four bands of Moderate Resolution Imaging Spectroradiometer (MODIS). The results of two methods were compared with result of MODIS on-board calibrator. The comparison shows that the result of irradiance-based method has a good consistency with on-board calibration and reflectance-based method results. The difference of calibration coefficients between irradiance-based and on-board method was less than 1.4%. Due to the limitations of the irradiance-based method, a clear sky and stable atmospheric condition is required for the entire half of the calibration day to provide the data necessary for the extrapolation of diffuse-to-global ratio in viewing direction. A study on the effects of aerosol mode assumption on the final apparent reflectance was performed on both the irradiance-based method and the reflectance-based method by selecting different aerosol modes to predict the apparent reflectance. The results show that aerosol mode assumption has a great effect on the reflectance-based method, however slight effect on the irradiance-based method.

  2. Evaluation of a rapid radiometric differentiation test for the Mycobacterium tuberculosis complex by selective inhibition with p-nitro-alpha-acetylamino-beta-hydroxypropiophenone

    SciTech Connect

    Laszlo, A.; Siddiqi, S.H.

    1984-05-01

    This study is an evaluation of a rapid technique for the differentiation of the Mycobacterium tuberculosis complex from other mycobacteria, using p-nitro-alpha-acetylamino-beta- hydroxypropiophenone (NAP) as a selective inhibitory agent. A total of 416 coded cultures, 234 cultures belonging to the M. tuberculosis complex and 182 cultures belonging to 35 other mycobacterial species, were tested in two laboratories for p-nitro-alpha-acetylamino-beta- hydroxypropiophenone inhibition to concentrations of 5 and 10 micrograms of NAP per ml in Middlebrook 7H12 liquid medium. Two testing modes were compared: the indirect, in which a large bacterial inoculum was used from an isolated culture on a solid medium, and the direct, which used a small inoculum from 7H12 medium. A decrease or no increase in daily /sup 14/CO/sub 2/ output as measured by a BACTEC system was considered evidence of inhibition. The data presented show that a concentration of 5 micrograms of NAP per ml can effectively separate the M. tuberculosis complex from other mycobacterial species in 4 to 6 days. The direct test data show that, unlike other conventional biochemical tests, it does not require a heavy inoculum of mycobacteria and can therefore be performed soon after growth is detected by the radiometric method.

  3. Evaluation of a radiometric method for pyrazinamide susceptibility testing of Mycobacterium tuberculosis.

    PubMed Central

    Tarrand, J J; Spicer, A D; Gröschel, D H

    1986-01-01

    Pyrazinamide susceptibility testing of Mycobacterium tuberculosis requires an acid environment. By controlling the method of acidification and the quality and quantity of the inoculum, the test can be performed with the BACTEC radiometric system (Johnston Laboratories, Towson, Md.). We acidified BACTEC 7H12 medium with buffered phosphoric acid and adjusted the test inoculum to 1/10 of that usually employed in BACTEC protocols; after 5 days of growth we correctly identified 36 of 36 strains susceptible to 50 micrograms of pyrazinamide per ml. All 18 resistant strains were classified as pyrazinamide resistant. (Susceptibility or resistance had been determined by standard plate assays.) The test was able to detect small resistant populations in artificial mixtures of 1 or 2% resistant bacteria with a susceptible strain (10 mixtures each). We tested 70 M. tuberculosis strains in acidified BACTEC 7H12 medium and by the plate dilution test at pH 5.5. All strains grew in the BACTEC medium, but three strains failed to grow on plates and were not tested further; the results of both methods agreed for the remaining strains. PMID:3101586

  4. Rapid Statistical Methods: Part 1.

    ERIC Educational Resources Information Center

    Lyon, A. J.

    1980-01-01

    Discusses some rapid statistical methods which are intended for use by physics teachers. Part one of this article gives some of the simplest and most commonly useful rapid methods. Part two gives references to the relevant theory together with some alternative and additional methods. (HM)

  5. A simple and effective radiometric correction method to improve landscape change detection across sensors and across time

    USGS Publications Warehouse

    Chen, X.; Vierling, Lee; Deering, D.

    2005-01-01

    Satellite data offer unrivaled utility in monitoring and quantifying large scale land cover change over time. Radiometric consistency among collocated multi-temporal imagery is difficult to maintain, however, due to variations in sensor characteristics, atmospheric conditions, solar angle, and sensor view angle that can obscure surface change detection. To detect accurate landscape change using multi-temporal images, we developed a variation of the pseudoinvariant feature (PIF) normalization scheme: the temporally invariant cluster (TIC) method. Image data were acquired on June 9, 1990 (Landsat 4), June 20, 2000 (Landsat 7), and August 26, 2001 (Landsat 7) to analyze boreal forests near the Siberian city of Krasnoyarsk using the normalized difference vegetation index (NDVI), enhanced vegetation index (EVI), and reduced simple ratio (RSR). The temporally invariant cluster (TIC) centers were identified via a point density map of collocated pixel VIs from the base image and the target image, and a normalization regression line was created to intersect all TIC centers. Target image VI values were then recalculated using the regression function so that these two images could be compared using the resulting common radiometric scale. We found that EVI was very indicative of vegetation structure because of its sensitivity to shadowing effects and could thus be used to separate conifer forests from deciduous forests and grass/crop lands. Conversely, because NDVI reduced the radiometric influence of shadow, it did not allow for distinctions among these vegetation types. After normalization, correlations of NDVI and EVI with forest leaf area index (LAI) field measurements combined for 2000 and 2001 were significantly improved; the r 2 values in these regressions rose from 0.49 to 0.69 and from 0.46 to 0.61, respectively. An EVI "cancellation effect" where EVI was positively related to understory greenness but negatively related to forest canopy coverage was evident across a

  6. Correction to Method of Establishing the Absolute Radiometric Accuracy of Remote Sensing Systems While On-orbit Using Characterized Stellar Sources

    NASA Technical Reports Server (NTRS)

    Bowen, Howard S.; Cunningham, Douglas M.

    2007-01-01

    The contents include: 1) Brief history of related events; 2) Overview of original method used to establish absolute radiometric accuracy of remote sensing instruments using stellar sources; and 3) Considerations to improve the stellar calibration approach.

  7. Validation of rapid microbiological methods.

    PubMed

    Peris-Vicente, Juan; Carda-Broch, Samuel; Esteve-Romero, Josep

    2015-06-01

    Classical microbiological methods currently have unacceptably long cycle times. Rapid microbiological methods have been available on the market for decades and have been applied by the clinical and food industries. However, their implementation in the pharmaceutical industry has been hampered by stringent regulations on validation and comparison with classical methods. To encourage the implementation of these methodologies, they must be validated to assess that the results are straightforward. A comparison with traditional methods should be also performed. In this review, information about the validation of rapid microbiological methods reported in the literature is provided as well as an explanation of the difficulty of validation of these methods. A comparison with traditional methods is also discussed. This information is useful for industries and laboratories that can potentially implement these methods. © 2014 Society for Laboratory Automation and Screening.

  8. Rapid Detection of Mycobacterium paratuberculosis in Clinical Samples from Ruminants and in Spiked Environmental Samples by Modified BACTEC 12B Radiometric Culture and Direct Confirmation by IS900 PCR

    PubMed Central

    Whittington, R. J.; Marsh, I.; Turner, M. J.; McAllister, S.; Choy, E.; Eamens, G. J.; Marshall, D. J.; Ottaway, S.

    1998-01-01

    The suitability of a radiometric culture medium consisting of BACTEC 12B with PANTA PLUS, mycobactin J, and egg yolk was evaluated for detection of Mycobacterium paratuberculosis in feces, mesenteric lymph nodes, and intestinal walls from cattle, sheep, and goats. In addition, a simple method that would enable the rapid identification of Mycobacterium paratuberculosis by IS900 PCR in the primary cultures was sought so that subculture to secondary egg-free radiometric medium could be avoided. An ethanol extraction followed by differential centrifugation was used to separate M. paratuberculosis from PCR inhibitors in the primary culture. PCR was then undertaken with the pellet, after boiling to lyse the mycobacteria; if this test was negative, the DNA in the lysate was purified with guanidine thiocyanate and silica. Cultures of feces, ilea, and mesenteric lymph nodes from cattle, sheep, and goats known to have or suspected of having Johne’s disease yielded positive PCR results 1 to 7 weeks after inoculation. Similar results were obtained with soil and pasture samples that had been spiked with M. paratuberculosis. The results suggested that radiometric culture was more sensitive than histopathology in detecting M. paratuberculosis infection in sheep and goats and more sensitive than culture on Herrold’s egg yolk medium for the detection of the infection in cattle. Of 259 individual PCR tests with samples from cultures with growth indices of ≥10,237 (91.5%) were positive, with only 28 (11.8%) requiring both ethanol and silica preparation to yield a positive result. Of the 22 negative PCR results for samples from cultures with growth indices of ≥10, 18 were for samples from cultures that had only just developed evidence of growth. PCR-positive cultures tended to remain PCR positive over successive weeks. Flexibility in the timing of the sampling for PCR is thus possible, facilitating batch processing of samples in large-scale disease control programs for

  9. Radiometric Dating Does Work!

    ERIC Educational Resources Information Center

    Dalrymple, G. Brent

    2000-01-01

    Discusses the accuracy of dating methods and creationist arguments that radiometric dating does not work. Explains the Manson meteorite impact and the Pierre shale, the ages of meteorites, the K-T tektites, and dating the Mount Vesuvius eruption. (Author/YDS)

  10. Radiometric Dating Does Work!

    ERIC Educational Resources Information Center

    Dalrymple, G. Brent

    2000-01-01

    Discusses the accuracy of dating methods and creationist arguments that radiometric dating does not work. Explains the Manson meteorite impact and the Pierre shale, the ages of meteorites, the K-T tektites, and dating the Mount Vesuvius eruption. (Author/YDS)

  11. A Method to Estimate Uncertainty in Radiometric Measurement Using the Guide to the Expression of Uncertainty in Measurement (GUM) Method; NREL (National Renewable Energy Laboratory)

    SciTech Connect

    Habte, A.; Sengupta, M.; Reda, I.

    2015-03-01

    Radiometric data with known and traceable uncertainty is essential for climate change studies to better understand cloud radiation interactions and the earth radiation budget. Further, adopting a known and traceable method of estimating uncertainty with respect to SI ensures that the uncertainty quoted for radiometric measurements can be compared based on documented methods of derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM). derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM).

  12. A Method to Assess Urban Surface Heat Islands using Hemispherical Radiometric Temperatures.

    NASA Astrophysics Data System (ADS)

    Allen, M. A.; Voogt, J. A.; Christen, A.

    2016-12-01

    The temporal and geometric representivity of satellite thermal remote sensing of urban surface climates is limited by three main deficiencies: 1. Geometric undersampling of vertical and sloped urban facets. 2. Temporal discontinuity in satellite overpass cycles. 3. Clear sky bias. To overcome these limitations, in this work we use a continuous time series of data from tower-mounted, downward-facing pyrgeometers to derive urban and rural hemispheric radiometric surface temperatures and their associated surface urban heat island (sUHI) magnitudes. These measurements provide a sampling of a full range of vertical, sloped and horizontal urban surfaces. A pyrgeometer's wide field-of-view and broadband spectral response make derived radiative surface temperatures particularly susceptible to atmospheric influence. This is further compounded by differences in instrument height at urban ( 30m) and rural ( 2m) sites. Thus, hemispherical brightness temperatures are corrected to quantify and remove atmospheric effects using the MODTRAN 4.1 radiative transfer code in conjunction with the Surface-Sensor-Sun Urban Model (SUM) to model hemispherical irradiances as `seen' by the sensor for the range of ambient conditions recorded at the study sites. Path length geometries are calculated in SUM by projecting the sensor field-of-view onto a digital building model and calculating average distances between the surface and the sensor at 5° intervals. These data are aggregated into a lookup table relating modeled at-sensor irradiances to air temperatures, humidities, and corrected surface temperatures. Measured irradiances and ambient conditions from the BUBBLE (Basel Urban Boundary Layer Experiment) are then matched with their modeled counterparts to retrieve a climatology of hemispherical radiometric surface temperatures. sUHI magnitudes are then calculated as the difference between corrected urban and rural temperatures This study aims to develop a temporally continuous climatology

  13. Simplified Vicarious Radiometric Calibration

    NASA Technical Reports Server (NTRS)

    Stanley, Thomas; Ryan, Robert; Holekamp, Kara; Pagnutti, Mary

    2010-01-01

    A measurement-based radiance estimation approach for vicarious radiometric calibration of spaceborne multispectral remote sensing systems has been developed. This simplified process eliminates the use of radiative transfer codes and reduces the number of atmospheric assumptions required to perform sensor calibrations. Like prior approaches, the simplified method involves the collection of ground truth data coincident with the overpass of the remote sensing system being calibrated, but this approach differs from the prior techniques in both the nature of the data collected and the manner in which the data are processed. In traditional vicarious radiometric calibration, ground truth data are gathered using ground-viewing spectroradiometers and one or more sun photometer( s), among other instruments, located at a ground target area. The measured data from the ground-based instruments are used in radiative transfer models to estimate the top-of-atmosphere (TOA) target radiances at the time of satellite overpass. These TOA radiances are compared with the satellite sensor readings to radiometrically calibrate the sensor. Traditional vicarious radiometric calibration methods require that an atmospheric model be defined such that the ground-based observations of solar transmission and diffuse-to-global ratios are in close agreement with the radiative transfer code estimation of these parameters. This process is labor-intensive and complex, and can be prone to errors. The errors can be compounded because of approximations in the model and inaccurate assumptions about the radiative coupling between the atmosphere and the terrain. The errors can increase the uncertainty of the TOA radiance estimates used to perform the radiometric calibration. In comparison, the simplified approach does not use atmospheric radiative transfer models and involves fewer assumptions concerning the radiative transfer properties of the atmosphere. This new technique uses two neighboring uniform

  14. Rapid presumptive identification of the Mycobacterium tuberculosis-bovis complex by radiometric determination of heat stable urease

    SciTech Connect

    Gandy, J.H.; Pruden, E.L.; Cox, F.R.

    1983-12-01

    Simple and rapid Bactec methodologies for the determination of neat (unaltered) and heat stable urease activity of mycobacteria are presented. Clinical isolates (63) and stock cultures (32)--consisting of: M. tuberculosis (19), M. bovis (5), M. kansasii (15), M. marinum (4), M. simiae (3), M. scrofulaceum (16), M. gordonae (6), M. szulgai (6), M. flavescens (1), M. gastri (1), M. intracellulare (6), M. fortuitum-chelonei complex (12), and M. smegmatis (1)--were tested for neat urease activity by Bactec radiometry. Mycobacterial isolates (50-100 mg wet weight) were incubated at 35 degrees C for 30 minutes with microCi14C-urea. Urease-positive mycobacteria gave Bactec growth index (GI) values greater than 100 units, whereas urease-negative species gave values less than 10 GI units. Eighty-three isolates possessing neat urease activity were heated at 80 degrees C for 30 minutes followed by incubation at 35 degrees C for 30 minutes with 1 microCi14C-urea. Mycobacterium tuberculosis-bovis complex demonstrated heat-stable urease activity (GI more than 130 units) and could be distinguished from mycobacteria other than tuberculosis (MOTT), which gave GI values equal to or less than 40 units.

  15. Rapid method to determine actinides and 89/90Sr in limestone and marble samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; ...

    2016-04-12

    A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89/90Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. Lastly, this approach has a sample preparation time for limestone and marble samples of <4 hours.

  16. Radiometric framework for image mosaicking.

    PubMed

    Litvinov, Anatoly; Schechner, Yoav Y

    2005-05-01

    Nonuniform exposures often affect imaging systems, e.g., owing to vignetting. Moreover, the sensor's radiometric response may be nonlinear. These characteristics hinder photometric measurements. They are particularly annoying in image mosaicking, in which images are stitched to enhance the field of view. Mosaics suffer from seams stemming from radiometric inconsistencies between raw images. Prior methods feathered the seams but did not address their root cause. We handle these problems in a unified framework. We suggest a method for simultaneously estimating the radiometric response and the camera nonuniformity, based on a frame sequence acquired during camera motion. The estimated functions are then compensated for. This permits image mosaicking, in which no seams are apparent. There is no need to resort to dedicated seam-feathering methods. Fundamental ambiguities associated with this estimation problem are stated.

  17. Airborne microwave radiometric imaging system

    NASA Astrophysics Data System (ADS)

    Guo, Wei; Zhang, Zuyin; Chen, Zhengwen

    1998-08-01

    A dual channel Airborne Microwave Radiometric Imaging system (AMRI) was designed and constructed for regional environment mapping. The system operates at 35GHz, which collects radiation at horizontal and vertical polarized. It runs at mechanical conical scanning with 45 degrees incidence angle. Two Cassegrain antennas with 1.5 degrees 3 dB beamwidth scan the scene alternately and two pseudo-color images of two channels are displayed on the screen of PC in real time. Simultaneously all parameters of flight and radiometric data are stored in hard disk for postprocessing. The sensitivity of the radiometers of flight and radiometric data are stored in hard disk for postprocessing. The sensitivity of the radiometers (Delta) T equals 0.16K. A new display method, unequal size element arc displaying method, is used in image displaying. Several experiments on mobile tower were carried out and the images demonstrate the AMRI is available to work steadily and accurately.

  18. Detection of circulating immune complexes by Raji cell assay: comparison of flow cytometric and radiometric methods

    SciTech Connect

    Kingsmore, S.F.; Crockard, A.D.; Fay, A.C.; McNeill, T.A.; Roberts, S.D.; Thompson, J.M.

    1988-01-01

    Several flow cytometric methods for the measurement of circulating immune complexes (CIC) have recently become available. We report a Raji cell flow cytometric assay (FCMA) that uses aggregated human globulin (AHG) as primary calibrator. Technical advantages of the Raji cell flow cytometric assay are discussed, and its clinical usefulness is evaluated in a method comparison study with the widely used Raji cell immunoradiometric assay. FCMA is more precise and has greater analytic sensitivity for AHG. Diagnostic sensitivity by the flow cytometric method is superior in systemic lupus erythematosus (SLE), rheumatoid arthritis, and vasculitis patients: however, diagnostic specificity is similar for both assays, but the reference interval of FCMA is narrower. Significant correlations were found between CIC levels obtained with both methods in SLE, rheumatoid arthritis, and vasculitis patients and in longitudinal studies of two patients with cerebral SLE. The Raji cell FCMA is recommended for measurement of CIC levels to clinical laboratories with access to a flow cytometer.

  19. A comparison of radiometric normalization methods when filling cloud gaps in Lansat imagery.

    Treesearch

    E. H. Helmer

    2007-01-01

    Mapping persistently cloudy tropical landscapes with optical satellite imagenery usually requires assembling the clear imagery from several dates. this study compares methods for normalizing image data when filling cloud gaps in Landsat imagery with imagery from other dates.

  20. Analytical laboratories method No. 4017 - the radiometric nondestructive analysis of Uranium-235 in uranium tetrafluoride

    SciTech Connect

    Not Available

    1987-01-27

    This method permits the nondestructive measurement of U-235 in uranium tetrafluoride (UF/sub 4/) using a Ge(Li) gamma spectrometer. The method was evaluated for UF/sub 4/ in the 0.20 to 1.25 wt% U-235 concentration range, but it could be easily extended to higher U-235 concentrations by using the appropriate standard. A nondestructive U-235 measurement can be performed in about 20 minutes. No measurement interferences have been observed.

  1. Analytical laboratories method No. 4011 - radiometric determination of uranium-232 in uranium bearing materials

    SciTech Connect

    Not Available

    1987-01-14

    The method is designed for use on recycled uranium materials and is applicable to materials that will yield at least 100 mg of uranium. Typical analysis time is 24 to 30 hours. U-232 can be measured to a lower limit of detection of 1 ppb (U-235 basis).

  2. Comparison of thiaminase activity in fish using the radiometric and 4-nitrothiophenol colorimetric methods

    USGS Publications Warehouse

    Honeyfield, D.C.; Hanes, J.W.; Brown, L.; Kraft, C.E.; Begley, T.P.

    2010-01-01

    Thiaminase induced thiamine deficiency occurs in fish, humans, livestock and wild animals. A non-radioactive thiaminase assay was described in 2007, but a direct comparison with the radioactive 14C-thiamine method which has been in use for more than 30years has not been reported. The objective was to measure thiaminase activity in forage fish (alewife Alosa pseudoharengus, rainbow smelt Osmerus mordax, and slimy sculpin Cottus cognatus) consumed by predators that manifest thiamine deficiency using both methods. Modifications were made to the colorimetric assay to improve repeatability. Modification included a change in assay pH, enhanced sample clean-up, constant assay temperature (37??C), increase in the concentration of 4-nitrothiophenol (4NTP) and use of a spectrophotometer fitted with a 0.2cm cell. A strong relationship between the two assays was found for 51 alewife (R2=0.85), 36 smelt (R2=0.87) and 20 sculpin (R2=0.82). Thiaminase activity in the colorimetric assay was about 1000 times higher than activity measured by the radioactive method. Application of the assay to fish species from which no thiaminase activity has previously been reported resulted in no 4NTP thiaminase activity being found in bloater Coregonus hoyi, lake trout Salvelinus namaycusch, steelhead trout Oncorhynchus mykiss or Chinook salmon Oncorhynchus tshawytscha. In species previously reported to contain thiaminase, 4NTP thiaminase activity was measured in bacteria Paenibacillus thiaminolyticus, gizzard shad Dorosoma cepedianum, bracken fern Pteridium aquilinum, quagga mussel Dreissena bugensis and zebra mussels D. polymorpha. ?? 2010.

  3. Radiometric method for determining concentration of naturally occurring isotopes and device therefor

    SciTech Connect

    Yakubovich, S.L.; Gerling, V.E.; Golubnichy, V.V.; Kotsen, M.E.; Stepanov, J.N.

    1984-10-09

    The proposed method essentially consists in that a sample of a substance is placed between two scintillators in immediate contact therewith whereupon said sample is hermetically sealed. Arranged in close proximity to each scintillator is a photomultiplier tube recording ionizing ..cap alpha..- and b-radiation. A selector is utilized to select pulses corresponding to ..cap alpha..- and b-particles, and delayed coincidence circuits of a recording element separate and record b-..cap alpha.. and ..cap alpha..-..cap alpha.. cascade pairs of delayed coincidences of RaC, ThC, and AcA radionuclides. Flows are measured twice at a predetermined time interval to account for emanation build-up tendency and concentration of isotopes of radium is determined from a formula.

  4. Rapid Radiochemical Methods for Selected Radionuclides

    EPA Pesticide Factsheets

    The rapid methods documents are supplement guidance in a planned series designed to present radioanalytical laboratory personnel, Incident Commanders (and their designees), and other field response personnel.

  5. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples

    NASA Astrophysics Data System (ADS)

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  6. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples.

    PubMed

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  7. Rapid drug susceptibility of Mycobacterium avium complex using a fluorescence quenching method.

    PubMed

    Marone, P; Bono, L; Carretto, E; Barbarini, D; Telecco, S

    1997-08-01

    Mycobacteria Growth Indicator Tube (MGIT) is a recently introduced rapid growth detection method which uses an oxygen quenched fluorescent indicator. The present study evaluated the ability of this new method to determine the drug susceptibility of Mycobacterium avium complex (MAC). Thirty strains recovered from patients with AIDS were tested for susceptibility to clarithromycin, rifabutin, ciprofloxacin, azithromycin and amikacin using MGIT. Results were compared to susceptibilities determined by the agar dilution method. The results obtained showed a 100% correlation between MGIT and the agar dilution method for rifabutin and clarithromycin. There was a 100% correlation between the two methods for azithromycin against 27 strains. MGIT was well correlated with the agar dilution method for detecting resistance to clarithromycin, rifabutin and azithromycin in 4 days, but the correlation was poor when susceptibilities to ciprofloxacin and amikacin were determined. This rapid method is non-radiometric, noninvasive and does not require any special instruments.

  8. Methods of Rapid Evaluation, Assessment, and Appraisal

    ERIC Educational Resources Information Center

    McNall, Miles; Foster-Fishman, Pennie G.

    2007-01-01

    A central issue in the use of rapid evaluation and assessment methods (REAM) is achieving a balance between speed and trustworthiness. In this article, the authors review the key differences and common features of this family of methods and present a case example that illustrates how evaluators can use rapid evaluation techniques in their own…

  9. FNAS/Rapid Spectral Inversion Methods

    NASA Technical Reports Server (NTRS)

    Poularikas, Alexander

    1997-01-01

    The purpose of this investigation was to study methods and ways for rapid inversion programs involving the correlated k-method, and to study the infrared observations of Saturn from the Cassini orbiter.

  10. [Rapid prototyping: a very promising method].

    PubMed

    Haverman, T M; Karagozoglu, K H; Prins, H-J; Schulten, E A J M; Forouzanfar, T

    2013-03-01

    Rapid prototyping is a method which makes it possible to produce a three-dimensional model based on two-dimensional imaging. Various rapid prototyping methods are available for modelling, such as stereolithography, selective laser sintering, direct laser metal sintering, two-photon polymerization, laminated object manufacturing, three-dimensional printing, three-dimensional plotting, polyjet inkjet technology,fused deposition modelling, vacuum casting and milling. The various methods currently being used in the biomedical sector differ in production, materials and properties of the three-dimensional model which is produced. Rapid prototyping is mainly usedforpreoperative planning, simulation, education, and research into and development of bioengineering possibilities.

  11. Patch Antenna for Measuring the Internal Temperature of Biological Objects Using the Near-Field Microwave Radiometric Method

    NASA Astrophysics Data System (ADS)

    Ubaichin, A.; Bespalko, A.; Filatov, A.; Alexeev, E.; Zhuk, G.

    2016-01-01

    The near-field microwave antenna with central frequency of 2.23 GHz has been designed and manufactured to be used as a part of the medical microwave radiometric system. Experimental studies of the reflection coefficient in different parts of the human body were conducted using the developed antenna. The experimental studies were carried out in a group of volunteers with normal somatic growth. The results of the experiments were used to perform the analysis of the potential errors in the measurements obtained via the developed antenna.

  12. Radiometric correction procedure study

    NASA Technical Reports Server (NTRS)

    Colby, C.; Sands, R.; Murphrey, S.

    1978-01-01

    A comparison of MSS radiometric processing techniques identified as a preferred radiometric processing technique a procedure which equalizes the mean and standard deviation of detector-specific histograms of uncalibrated scene data. Evaluation of MSS calibration data demonstrated that the relationship between detector responses is essentially linear over the range of intensities typically observed in MSS data, and that the calibration wedge data possess a high degree of temporal stability. An analysis of the preferred radiometric processing technique showed that it could be incorporated into the MDP-MSS system without a major redesign of the system, and with minimal impact on system throughput.

  13. Comparison of agar dilution, broth microdilution, disk diffusion, E-test, and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex.

    PubMed Central

    Ambaye, A; Kohner, P C; Wollan, P C; Roberts, K L; Roberts, G D; Cockerill, F R

    1997-01-01

    An evaluation was undertaken to determine the optimal method for the in vitro susceptibility testing of 26 Nocardia asteroides complex isolates to the following antimicrobial agents: amikacin, ampicillin, amoxicillin-clavulanate, ceftriaxone, ciprofloxacin, erythromycin, imipenem, minocycline, and trimethoprim-sulfamethoxazole. Five testing methods were studied including the agar dilution, broth microdilution, and disk diffusion methods, the epsilometer test (E-test), and the BACTEC radiometric method. Results for each antimicrobial agent and each testing method were interpreted as indicating susceptibility, intermediate susceptibility, or resistance according to current guidelines of the National Committee for Clinical Laboratory Standards (NCCLS) for bacteria that grow aerobically and were then compared to a "gold standard" susceptibility test result. The gold standard result for each Nocardia isolate was established by a consensus of the results of the majority of testing methods used in the study. When the results were combined for all antimicrobial agents tested against all Nocardia isolates by all methods, the BACTEC radiometric method produced the highest level of agreement (97.9%) with the consensus results and had the fewest very major (n = 1), major (n = 2), and minor (n = 2) errors. In contrast, the results of the agar dilution method were in least agreement (93.2%) with the consensus results, and this method also produced the most very major (n = 8), major (n = 4), and, along with the disk diffusion method, minor (n = 6) errors. For all test methods, interpretive errors were most frequent when testing ampicillin or amoxicillin-clavulanate. Moreover, for all Nocardia nova isolates tested, ampicillin susceptibility results by any of the testing methods were not in agreement with the results of testing for beta-lactamase by the nitrocefin (Cefinase) disk method. We conclude that among the methods evaluated, the BACTEC radiometric method appeared to be the

  14. A scoping review of rapid review methods.

    PubMed

    Tricco, Andrea C; Antony, Jesmin; Zarin, Wasifa; Strifler, Lisa; Ghassemi, Marco; Ivory, John; Perrier, Laure; Hutton, Brian; Moher, David; Straus, Sharon E

    2015-09-16

    Rapid reviews are a form of knowledge synthesis in which components of the systematic review process are simplified or omitted to produce information in a timely manner. Although numerous centers are conducting rapid reviews internationally, few studies have examined the methodological characteristics of rapid reviews. We aimed to examine articles, books, and reports that evaluated, compared, used or described rapid reviews or methods through a scoping review. MEDLINE, EMBASE, the Cochrane Library, internet websites of rapid review producers, and reference lists were searched to identify articles for inclusion. Two reviewers independently screened literature search results and abstracted data from included studies. Descriptive analysis was conducted. We included 100 articles plus one companion report that were published between 1997 and 2013. The studies were categorized as 84 application papers, seven development papers, six impact papers, and four comparison papers (one was included in two categories). The rapid reviews were conducted between 1 and 12 months, predominantly in Europe (58 %) and North America (20 %). The included studies failed to report 6 % to 73 % of the specific systematic review steps examined. Fifty unique rapid review methods were identified; 16 methods occurred more than once. Streamlined methods that were used in the 82 rapid reviews included limiting the literature search to published literature (24 %) or one database (2 %), limiting inclusion criteria by date (68 %) or language (49 %), having one person screen and another verify or screen excluded studies (6 %), having one person abstract data and another verify (23 %), not conducting risk of bias/quality appraisal (7 %) or having only one reviewer conduct the quality appraisal (7 %), and presenting results as a narrative summary (78 %). Four case studies were identified that compared the results of rapid reviews to systematic reviews. Three studies found that the conclusions between

  15. Airborne microwave radiometric imaging system

    NASA Astrophysics Data System (ADS)

    Guo, Wei; Li, Futang; Zhang, Zuyin

    1999-09-01

    A dual channel Airborne Microwave Radiometric Imaging system (AMRI) was designed and constructed for regional environment mapping. The system operates at 35GHz, which collects radiation at horizontal and vertical polarized channels. It runs at mechanical conical scanning with 45 degrees incidence angle. Two Cassegrain antennas with 1.5 degrees beamwidth scan the scene alternately and two pseudo- color images of two channels are displayed on the screen of PC in real time. Simultaneously, all parameters of flight and radiometric data are sorted in hard disk for post- processing. The sensitivity of the radiometer (Delta) T equals 0.16K. A new displaying method, unequal size element arc displaying method, is used in image displaying. Several experiments on mobile tower were carried out and the images demonstrate that the AMRI is available to work steadily and accurately.

  16. Rapid extraction methods for organics in soil

    SciTech Connect

    Alsop, G.M.; Conway, R.A.

    1983-03-01

    This article presents rapid methods for the extraction and subsequent analysis of organics in soils potentially contaminated from chemical wastes. A methylene chloride extraction, on both a micro scale in a syringe and a macro scale in a shaken flask, with subsequent gravimetric analysis are described. On wet soils, anhydrous sodium sulfate is added to bind the water before adding methylene chloride and mixing with a vortex touch mixer. A baseline procedure is the direct gravimetric determination of volatile organics corrected with a Karl Fischer determination of water. Estimates of time saved by using the rapid methods, as well as precision and accuracy data, are presented.

  17. Rapid method to determine actinides and 89/90Sr in limestone and marble samples

    SciTech Connect

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; Utsey, Robin C.; Sudowe, Ralf; McAlister, Daniel R.

    2016-04-12

    A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89/90Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. Lastly, this approach has a sample preparation time for limestone and marble samples of <4 hours.

  18. Rapid Radiochemical Methods for Asphalt Paving Material ...

    EPA Pesticide Factsheets

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  19. Results of magnetic HGI and radiometric surveys in W. Canada

    SciTech Connect

    LeSchack, L.A.

    1997-05-19

    This article presents four case histories in which ground-based magnetic horizontal gradient intensity (HGI) and radiometric surveys were used in Western Canada for cost-effective geochemical exploration for hydrocarbons. The authors has developed these two surface exploration techniques from published studies and adapted them for use on the prairies the past 7 years. These surveys are used in conjunction with the usual geologic and seismic studies for: (1) evaluating prospects and land; (2) verifying seismic anomalies and inexpensively locating areas for conducting expensive 3D seismic surveys. Occasionally, as in two of the case histories discussed, these surveys were used successfully as stand-alone exploration methods where seismic exploration is not effective. The HGI and radiometric surveys measure, by geophysical methods, those effects associated with geochemical alterations due to vertical microseepage of hydrocarbons. The total cost, including permitting, data acquisition, data processing, and interpretation of the combination HGI and radiometric surveys is about 15% the total cost of a 3D seismic survey. Because of this, the author finds them an attractive and rapid survey adjunct to traditional exploration. They substantially reduce finding costs and significantly raise the probability of financial success.

  20. [Manipulation methods of slow-rapid reinforcing-reducing method].

    PubMed

    Zhao, Xi-Xin; Ran, Peng-Fei; Lü, Xiao-Rui; Wang, Xue-Xia

    2008-06-01

    After consulting literature, following the original meaning of the paper about slow-rapid reinforcing-reducing method in Huangdi's Internal Classic, in combination with explanation of later ages, and comprehension and clinical experience of the authors, it is put forward that the slow-rapid reinforcing-reducing method in Huangdi's Internal Classic is not single manipulation method, but it is a guiding principle for reinforcing-reducing manipulation, it includes many manipulation methods and they were listed, and all of the reinforcing-reducing methods of later ages are developed from these. In the teaching material Acupuncture and Moxibustion Sciences they are included in single reinforcing-reducing method, reducing extension and intension of this definition. The relative description in the teaching material only is slow-rapid reinforcing-reducing method of narrow sense, but the manipulations can be divided into qi-carrying manipulating needle type and three-one pushing-pulling type.

  1. Rapid Adenovirus typing method for species identification.

    PubMed

    Rayne, Fabienne; Wittkop, Linda; Bader, Clément; Kassab, Somar; Tumiotto, Camille; Berciaud, Sylvie; Wodrich, Harald; Lafon, Marie-Edith

    2017-11-01

    Adenoviruses are characterized by a large variability, reflected by their classification in species A to G. Certain species, eg A and C, could be associated with increased clinical severity, both in immunocompetent and immunocompromised hosts suggesting that in some instances species identification provides clinically relevant information. Here we designed a novel "pVI rapid typing method" to obtain quick, simple and cost effective species assignment for Adenoviruses, thanks to combined fusion temperature (Tm) and amplicon size analysis. Rapid typing results were compared to Sanger sequencing in the hexon gene for 140 Adenovirus-positive clinical samples included in the Typadeno study. Species A and C could be identified with a 100% positive predictive value, thus confirming the value of this simple typing method. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Validation of Rapid Radiochemical Method for Californium ...

    EPA Pesticide Factsheets

    Technical Brief In the event of a radiological/nuclear contamination event, the response community would need tools and methodologies to rapidly assess the nature and the extent of contamination. To characterize a radiologically contaminated outdoor area and to inform risk assessment, large numbers of environmental samples would be collected and analyzed over a short period of time. To address the challenge of quickly providing analytical results to the field, the U.S. EPA developed a robust analytical method. This method allows response officials to characterize contaminated areas and to assess the effectiveness of remediation efforts, both rapidly and accurately, in the intermediate and late phases of environmental cleanup. Improvement in sample processing and analysis leads to increased laboratory capacity to handle the analysis of a large number of samples following the intentional or unintentional release of a radiological/nuclear contaminant.

  3. Methods of Recording Rapid Wind Changes

    NASA Technical Reports Server (NTRS)

    Magnan, A

    1932-01-01

    The purpose of our research was to determine the rapid changes of air currents which impose varying stresses on the wings of airplanes. We attempted to express in figures the turbulence of the air, which perhaps plays some role in the behavior of airplanes in flight, as well as in the realization of certain methods of gliding flight. This is the reason which led us to conceive and develop the experimental equipment (hot-wire anemometer) described herein.

  4. Broadband Radiometric LED Measurements

    PubMed Central

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2017-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed. PMID:28649167

  5. Small satellite radiometric measurements

    SciTech Connect

    Weber, P.G.

    1991-01-01

    A critical need for the Mission to Planet Earth is to provide continuous, well-calibrated radiometric data for the radiation budget. This paper describes a new, compact, flexible radiometer which will provide both spectrally integrated data and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted vehicles (RPVs). 12 refs., 2 figs.

  6. Broadband radiometric LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  7. Rapid Column Extraction method for SoilRapid Column Extraction method for Soil

    SciTech Connect

    Maxwell, Sherrod, L. III; Culligan, Brian K.

    2005-11-07

    The analysis of actinides in environmental soil and sediment samples is very important for environmental monitoring as well as for emergency preparedness. A new, rapid actinide separation method has been developed and implemented that provides total dissolution of large soil samples, high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and DGA-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu) neptunium (Np), uranium (U), americium (Am), and curium (Cm) using a single multi-stage column combined with alpha spectrometry. The method combines a rapid fusion step for total dissolution to dissolve refractory analytes and matrix removal using cerium fluoride precipitation to remove the difficult soil matrix. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized.

  8. Simple rapid method for gene transfer

    SciTech Connect

    Cockburn, A.F.; Meier, H.

    1990-01-30

    The object of the present invention is to provide methods for gene transfer that reduce or eliminate cellular pretreatment steps, e.g., the removal of cell wall by chemical or enzymatic methods, is rapid and can be practiced without the need of additional expensive equipment. Cells, embryos or tissues selected for genetic manipulation are suspended in an Eppendorf tube in an aliquot of the desired genetic material to be transferred to which the resulting mixture is added and is agitated by vortexing from about 30 to about 90 seconds. The cells, embryos or tissue are sedimented and the DNA supernatant removed. After sedimentation, the injected material is resuspended in or on a growth medium to assay for expression.

  9. Rapid Column Extraction Methods for Urine

    SciTech Connect

    Maxwell, S.L. III

    2000-06-09

    A new fecal analysis method that dissolves plutonium oxide was developed at the Westinghouse Savannah River Site. Diphonix Resin (Eichrom Industries), is used to pre-concentrate the actinides from digested fecal samples. A rapid microwave digestion technique is used to remove the actinides from the Diphonix Resin, which effectively extracts plutonium and americium from acidic solutions containing hydrofluoric acid. After resin digestion, the plutonium and americium are recovered in a small volume of nitric acid that is loaded onto small extraction chromatography columns, TEVA Resin and TRU Resin (Eichrom Industries). The method enables complete dissolution of plutonium oxide and provides high recovery of plutonium and americium with good removal of thorium isotopes such as thorium-228.

  10. Relative radiometric calibration of LANDSAT TM reflective bands

    NASA Technical Reports Server (NTRS)

    Barker, J. L.

    1984-01-01

    A common scientific methodology and terminology is outlined for characterizing the radiometry of both TM sensors. The magnitude of the most significant sources of radiometric variability are discussed and methods are recommended for achieving the exceptional potential inherent in the radiometric precision and accuracy of the TM sensors.

  11. Radiometric studies of Mycobacterium lepraemurium.

    PubMed

    Camargo, E E; Larson, S M; Tepper, B S; Wagner, H N

    1976-01-01

    The radiometric method has been applied for studying the metabolism of M. lepraemurium and the conditions which might force or inhibit its metabolic activity in vitro. These organisms assimilate and oxidize (U-14C) glycerol, and (U-14C) acetate, but are unable to oxidize (U-14C) glucose, (U-14C) pyruvate, (U-14C) glycine and 14C-formate. When incubated at 30 degrees C M. lepraemurium oxidizes (U-14C) acetate to 14CO2 faster than 37 degrees C. The smae effect was observed with increasing concentrations of polysorbate 80 (Tween 80), or the 14C-substrate. No change in metabolic rate was observed when the organisms were kept at -20 degrees C for 12 days. Although tried several times, it was not possible to demonstrate any "inhibitors" of bacterial metabolism in the reaction system. The radiometric method seems to be an important tool for studying metabolic pathways and the influence of physical and biochemical factors on the metabolism of M. lepraemurium in vitro.

  12. A method for sensible heat flux model parameterization based on radiometric surface temperature and environmental factors without involving the parameter KB-1

    NASA Astrophysics Data System (ADS)

    Zhuang, Qifeng; Wu, Bingfang; Yan, Nana; Zhu, Weiwei; Xing, Qiang

    2016-05-01

    Sensible heat flux is a key component of land-atmosphere interaction. In most parameterizations it is calculated with surface-air temperature differences and total aerodynamic resistance to heat transfer (Rae) that is related to the KB-1 parameter. Suitable values are hard to obtain since KB-1 is related both to canopy characteristics and environmental conditions. In this paper, a parameterize method for sensible heat flux over vegetated surfaces (maize field and grass land in the Heihe river basin of northwest China) was proposed based on the radiometric surface temperature, surface resistance (Rs) and vapor pressures (saturated and actual) at the surface and the atmosphere above the canopy. A biophysics-based surface resistance model was revised to compute surface resistance with several environmental factors. The total aerodynamic resistance to heat transfer is directly calculated by combining the biophysics-based surface resistance and vapor pressures. One merit of this method is that the calculation of KB-1 can be avoided. The method provides a new way to estimate sensible heat flux over vegetated surfaces and its performance compares well to the LAS measured sensible heat and other empirical or semi-empirical KB-1 based estimations.

  13. Fetal magnetocardiography: Methods for rapid data reduction

    NASA Astrophysics Data System (ADS)

    Mosher, John C.; Flynn, Edward R.; Quinn, A.; Weir, A.; Shahani, U.; Bain, R. J. P.; Maas, P.; Donaldson, G. B.

    1997-03-01

    Fetal magnetocardigraphy (fMCG) provides a unique method for noninvasive observations of the fetal heart. Electrical currents generated by excitable tissues within the fetal heart yield measurable external magnetic fields. Measurements are performed with superconducting quantum interference devices inductively coupled to magnetometer or gradiometer coils, and the resulting signals are converted to digital form in the data acquisition system. The measured fields are usually contaminated by fetal and maternal movements (usually respiration), other physiological fields such as skeletal muscle contraction, the maternal cardiac signal, and environmental electromagnetic fields. Sensitivity to relatively distant sources, both physiological and environmental, is substantially reduced by the use of magnetic gradiometers. Other contaminants may be removed by proper signal conditioning which may be automatically applied using "black box" algorithms that are transparent to the user and highly efficient. These procedures can rapidly reduce the complex signal plus noise waveforms to the desired fMCG with minimal operator interference.

  14. Preliminary Evaluation of the Radiometric Calibration of LANDSAT-4 Thematic Mapper Data by the Canada Centre for Remote Sensing

    NASA Technical Reports Server (NTRS)

    Murphy, J.; Park, W.; Fitzgerald, A.

    1985-01-01

    The radiometric characteristics of the LANDSAT-4 TM sensor are being studied with a view to developing absolute and relative radiometric calibration procedures. Preliminary results from several different approaches to the relative correction of all detectors within each band are reported. Topics covered include: the radiometric correction method; absolute calibration; the relative radiometric calibration algorithm; relative gain and offset calibration; relative gain and offset observations; and residual radiometric stripping.

  15. Radiometric detection of the metabolic activity of Mycobacterium tuberculosis.

    PubMed

    Cummings, D M; Ristroph, D; Camargo, E E; Larson, S M; Wagner, H N

    1975-12-01

    A radiometric test capable of detecting the metabolic rate of M. tuberculosis within 18 hr after inoculation has been developed. The technique is based on the measurement of 14CO2 produced by the bacterial metabolism of 14C-U-glycerol of 14C-U-acetate. The test is an important first step in the development of rapid radiometric techniques for clinical study of Mycobacterium tuberculosis.

  16. Radiometric sounding system

    SciTech Connect

    Whiteman, C.D.; Anderson, G.A.; Alzheimer, J.M.; Shaw, W.J.

    1995-04-01

    Vertical profiles of solar and terrestrial radiative fluxes are key research needs for global climate change research. These fluxes are expected to change as radiatively active trace gases are emitted to the earth`s atmosphere as a consequence of energy production and industrial and other human activities. Models suggest that changes in the concentration of such gases will lead to radiative flux divergences that will produce global warming of the earth`s atmosphere. Direct measurements of the vertical variation of solar and terrestrial radiative fluxes that lead to these flux divergences have been largely unavailable because of the expense of making such measurements from airplanes. These measurements are needed to improve existing atmospheric radiative transfer models, especially under the cloudy conditions where the models have not been adequately tested. A tethered-balloon-borne Radiometric Sounding System has been developed at Pacific Northwest Laboratory to provide an inexpensive means of making routine vertical soundings of radiative fluxes in the earth`s atmospheric boundary layer to altitudes up to 1500 m above ground level. Such vertical soundings would supplement measurements being made from aircraft and towers. The key technical challenge in the design of the Radiometric Sounding System is to develop a means of keeping the radiometers horizontal while the balloon ascends and descends in a turbulent atmospheric environment. This problem has been addressed by stabilizing a triangular radiometer-carrying platform that is carried on the tetherline of a balloon sounding system. The platform, carried 30 m or more below the balloon to reduce the balloon`s effect on the radiometric measurements, is leveled by two automatic control loops that activate motors, gears and pulleys when the platform is off-level. The sensitivity of the automatic control loops to oscillatory motions of various frequencies and amplitudes can be adjusted using filters.

  17. Kernel MAD Algorithm for Relative Radiometric Normalization

    NASA Astrophysics Data System (ADS)

    Bai, Yang; Tang, Ping; Hu, Changmiao

    2016-06-01

    The multivariate alteration detection (MAD) algorithm is commonly used in relative radiometric normalization. This algorithm is based on linear canonical correlation analysis (CCA) which can analyze only linear relationships among bands. Therefore, we first introduce a new version of MAD in this study based on the established method known as kernel canonical correlation analysis (KCCA). The proposed method effectively extracts the non-linear and complex relationships among variables. We then conduct relative radiometric normalization experiments on both the linear CCA and KCCA version of the MAD algorithm with the use of Landsat-8 data of Beijing, China, and Gaofen-1(GF-1) data derived from South China. Finally, we analyze the difference between the two methods. Results show that the KCCA-based MAD can be satisfactorily applied to relative radiometric normalization, this algorithm can well describe the nonlinear relationship between multi-temporal images. This work is the first attempt to apply a KCCA-based MAD algorithm to relative radiometric normalization.

  18. Fetal magnetocardiography: Methods for rapid data reduction

    SciTech Connect

    Mosher, J.C.; Flynn, E.R.; Quinn, A.; Weir, A.; Shahani, U.; Bain, R.J.; Maas, P.; Donaldson, G.B.

    1997-03-01

    Fetal magnetocardigraphy (fMCG) provides a unique method for noninvasive observations of the fetal heart. Electrical currents generated by excitable tissues within the fetal heart yield measurable external magnetic fields. Measurements are performed with superconducting quantum interference devices inductively coupled to magnetometer or gradiometer coils, and the resulting signals are converted to digital form in the data acquisition system. The measured fields are usually contaminated by fetal and maternal movements (usually respiration), other physiological fields such as skeletal muscle contraction, the maternal cardiac signal, and environmental electromagnetic fields. Sensitivity to relatively distant sources, both physiological and environmental, is substantially reduced by the use of magnetic gradiometers. Other contaminants may be removed by proper signal conditioning which may be automatically applied using {open_quotes}black box{close_quotes} algorithms that are transparent to the user and highly efficient. These procedures can rapidly reduce the complex signal plus noise waveforms to the desired fMCG with minimal operator interference. {copyright} {ital 1997 American Institute of Physics.}

  19. Radiometric correction of LANDSAT data

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N.; Kumar, R. (Principal Investigator); Cavalcanti, L. A.

    1977-01-01

    The author has identified the following significant results. The six independent sensors of the multispectral band scanner are supposed to be identical; however, in actual practice, they may have different gain settings and offset factors, which result in the effect known as stripping (black lines at regular intervals) of the imagery. A simple two parameter method to correct the gain settings and offset factors of each of the sensors with respect to one sensor, taken as reference, was developed. This method assumes: (1) the response of a detector varies linearly with the radiance of radiation received, and (2) the means, as well as the standard deviations, of a reasonably large number of pixels, in a given wavelength band, are equal for each of the detectors for the radiometrically corrected data.

  20. Radiometric and conventional drug susceptibility testing of Mycobacterium tuberculosis.

    PubMed

    Hoel, T; Eng, J

    1991-11-01

    One hundred and four clinical isolates of M. tuberculosis were susceptibility tested by the radiometric method (RAD) using the BACTEC system in parallel with a conventional modified proportion method (CON). In the latter, the strains were tested against four concentrations of drugs in Lowenstein-Jensen medium (isoniazid (INH), streptomycin (SM) and ethambutol (EMB)) OR 7H10 agar medium (rifampicin (RIF)) and reported as "sensitive", "intermediate" or "resistant" from the minimum inhibitory concentrations observed. The radiometric results were classified in the same three groups in accordance with the BACTEC methodology. The overall agreement between the results obtained by the two methods was 97.4% (INH 95.2%, EMB 96.2%, SM 98.1% and RIF 100%). In addition, the agreement between RAD and each of the drug concentration steps employed in CON was examined and the results discussed in relation to the established critical concentrations of the drugs. The BACTEC technique was found to be a rapid and convenient method for routine use.

  1. COMPARISON BETWEEN ELLMAN AND RADIOMETRIC METHODS FOR ASSESSING CHOLINESTERASE (CHE) INHIBITION IN RATS TREATED WITH N-METHYL CARBAMATE INSECTICIDES.

    EPA Science Inventory

    Carbamylated ChE is unstable and readily reactivates. This reactivation, promoted by increasing temperature and dilution, could have an impact on ex vivo ChE assays by decreasing apparent ChE inhibition. To assess the best method for measuring ChE inhibition in brain and RBCs f...

  2. COMPARISON BETWEEN ELLMAN AND RADIOMETRIC METHODS FOR ASSESSING CHOLINESTERASE (CHE) INHIBITION IN RATS TREATED WITH N-METHYL CARBAMATE INSECTICIDES.

    EPA Science Inventory

    Carbamylated ChE is unstable and readily reactivates. This reactivation, promoted by increasing temperature and dilution, could have an impact on ex vivo ChE assays by decreasing apparent ChE inhibition. To assess the best method for measuring ChE inhibition in brain and RBCs f...

  3. Aerial radiometric and magnetic reconnaissance survey of south-central Colorado Trinidad Quadrangle. Volume 1. Instrumentation and methods

    SciTech Connect

    Not Available

    1980-01-01

    Instrumentation and methods described were used for a Department of Energy (DOE) sponsored high-sensitivity, aerial gamma-ray spectrometer and magnetometer survey of the Trinidad, Colorado, NTMS, 1:250,000-scale quadrangle. The survey was carried out by Texas Instruments Incorporated under Bendix Field Engineering Corporation Subcontract No. 79-263-L. Objective of the work was to define areas showing surface indications of a generally higher uranium content where detailed exploration for uranium would most likely be successful.

  4. An alternative radiometric method for calculating the sedimentation rates: application to an intertidal region (SW of Spain).

    PubMed

    Ligero, R A; Casas-Ruiz, M; Barrera, M; Barbero, L; Meléndez, M J

    2010-09-01

    A new method using the inventory determined for the activity of the radionuclide (137)Cs, coming from global radioactive fallout has been utilised to calculate the sedimentation rates. The method has been applied in a wide intertidal region in the Bay of Cádiz Natural Park (SW Spain). The sedimentation rates estimated by the (137)Cs inventory method ranged from 0.26 cm/year to 1.72 cm/year. The average value of the sedimentation rate obtained is 0.59 cm/year, and this rate has been compared with those resulting from the application of the (210)Pb dating technique. A good agreement between the two procedures has been found. From the study carried out, it has been possible for the first time, to draw a map of sedimentation rates for this zone where numerous physico-chemical, oceanographic and ecological studies converge, since it is situated in a region of great environmental interest. This area, which is representative of common environmental coastal scenarios, is particularly sensitive to perturbations related to climate change, and the results of the study will allow to make short and medium term evaluations of this change.

  5. Dating human skeletal remains using a radiometric method: biogenic versus diagenetic 90Sr and 210Pb in vertebrae.

    PubMed

    Schrag, Bettina; Uldin, Tanya; Mangin, Patrice; Froidevaux, Pascal

    2012-07-10

    In forensic science, there is a strong interest in determining the post-mortem interval (PMI) of human skeletal remains up to 50 years after death. Currently, there are no reliable methods to resolve PMI, the determination of which relies almost exclusively on the experience of the investigating expert. Here we measured (90)Sr and (210)Pb ((210)Po) incorporated into bones through a biogenic process as indicators of the time elapsed since death. We hypothesised that the activity of radionuclides incorporated into trabecular bone will more accurately match the activity in the environment and the food chain at the time of death than the activity in cortical bone because of a higher remodelling rate. We found that determining (90)Sr can yield reliable PMI estimates as long as a calibration curve exists for (90)Sr covering the studied area and the last 50 years. We also found that adding the activity of (210)Po, a proxy for naturally occurring (210)Pb incorporated through ingestion, to the (90)Sr dating increases the reliability of the PMI value. Our results also show that trabecular bone is subject to both (90)Sr and (210)Po diagenesis. Accordingly, we used a solubility profile method to determine the biogenic radionuclide only, and we are proposing a new method of bone decontamination to be used prior to (90)Sr and (210)Pb dating.

  6. [Laser-based radiometric calibration].

    PubMed

    Li, Zhi-gang; Zheng, Yu-quan

    2014-12-01

    Increasingly higher demands are put forward to spectral radiometric calibration accuracy and the development of new tunable laser based spectral radiometric calibration technology is promoted, along with the development of studies of terrestrial remote sensing, aeronautical and astronautical remote sensing, plasma physics, quantitative spectroscopy, etc. Internationally a number of national metrology scientific research institutes have built tunable laser based spectral radiometric calibration facilities in succession, which are traceable to cryogenic radiometers and have low uncertainties for spectral responsivity calibration and characterization of detectors and remote sensing instruments in the UK, the USA, Germany, etc. Among them, the facility for spectral irradiance and radiance responsivity calibrations using uniform sources (SIRCCUS) at the National Institute of Standards and Technology (NIST) in the USA and the Tunable Lasers in Photometry (TULIP) facility at the Physikalisch-Technische Bundesanstalt (PTB) in Germany have more representatives. Compared with lamp-monochromator systems, laser based spectral radiometric calibrations have many advantages, such as narrow spectral bandwidth, high wavelength accuracy, low calibration uncertainty and so on for radiometric calibration applications. In this paper, the development of laser-based spectral radiometric calibration and structures and performances of laser-based radiometric calibration facilities represented by the National Physical Laboratory (NPL) in the UK, NIST and PTB are presented, technical advantages of laser-based spectral radiometric calibration are analyzed, and applications of this technology are further discussed. Laser-based spectral radiometric calibration facilities can be widely used in important system-level radiometric calibration measurements with high accuracy, including radiance temperature, radiance and irradiance calibrations for space remote sensing instruments, and promote the

  7. Radiometric Characterization of IKONOS Multispectral Imagery

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Ryan, Robert E.; Kelly, Michelle; Holekamp, Kara; Zanoni, Vicki; Thome, Kurtis; Schiller, Stephen

    2002-01-01

    A radiometric characterization of Space Imaging's IKONOS 4-m multispectral imagery has been performed by a NASA funded team from the John C. Stennis Space Center (SSC), the University of Arizona Remote Sensing Group (UARSG), and South Dakota State University (SDSU). Both intrinsic radiometry and the effects of Space Imaging processing on radiometry were investigated. Relative radiometry was examined with uniform Antarctic and Saharan sites. Absolute radiometric calibration was performed using reflectance-based vicarious calibration methods on several uniform sites imaged by IKONOS, coincident with ground-based surface and atmospheric measurements. Ground-based data and the IKONOS spectral response function served as input to radiative transfer codes to generate a Top-of-Atmosphere radiance estimate. Calibration coefficients derived from each vicarious calibration were combined to generate an IKONOS radiometric gain coefficient for each multispectral band assuming a linear response over the full dynamic range of the instrument. These calibration coefficients were made available to Space Imaging, which subsequently adopted them by updating its initial set of calibration coefficients. IKONOS imagery procured through the NASA Scientific Data Purchase program is processed with or without a Modulation Transfer Function Compensation kernel. The radiometric effects of this kernel on various scene types was also investigated. All imagery characterized was procured through the NASA Scientific Data Purchase program.

  8. Improved Absolute Radiometric Calibration of a UHF Airborne Radar

    NASA Technical Reports Server (NTRS)

    Chapin, Elaine; Hawkins, Brian P.; Harcke, Leif; Hensley, Scott; Lou, Yunling; Michel, Thierry R.; Moreira, Laila; Muellerschoen, Ronald J.; Shimada, Joanne G.; Tham, Kean W.; hide

    2015-01-01

    The AirMOSS airborne SAR operates at UHF and produces fully polarimetric imagery. The AirMOSS radar data are used to produce Root Zone Soil Moisture (RZSM) depth profiles. The absolute radiometric accuracy of the imagery, ideally of better than 0.5 dB, is key to retrieving RZSM, especially in wet soils where the backscatter as a function of soil moisture function tends to flatten out. In this paper we assess the absolute radiometric uncertainty in previously delivered data, describe a method to utilize Built In Test (BIT) data to improve the radiometric calibration, and evaluate the improvement from applying the method.

  9. An alternative method for the estimation of sedimentation rates using radiometric measurements in an intertidal region (sw of spain)

    NASA Astrophysics Data System (ADS)

    Ligero, Rufino; Casas-Ruiz, Melquiades; Barrera, Manuel; Barbero, Luis

    2010-05-01

    The techniques for the direct measurement of the sedimentation rate are reliable but slow and imprecise, given that the time intervals of measurement cannot be very long. Consequently it is an extremely laborious task to obtain a representative map of the sedimentation rates and such maps are available for very few zones. However, for most environmental studies, it is very important to know the sedimentation rates. The high degree of accuracy of the gamma spectrometric techniques together with the application of the model describes in this work, has allowed the determination of the sedimentation rates in a wide spatial area such of the Bay of Cadiz to be obtained with precision and consuming considerably less time in comparison to the traditional techniques. Even so, the experimental conditions required for the sample cores are fairly restrictive, and although the radiological method provides a quantitative advance in measurement, the experimental difficulty in the execution of the study is not greatly diminished. For this reason, a second model has been derived based on the measurement of the inventory, which offers economies in time and financial cost, and which allows the sedimentation rate in a region to be determined with satisfactory accuracy. Furthermore, it has been shown that the application of this model requires a precise determination of 137Cs inventories. The sedimentation rates estimated by the 137Cs inventory method ranged from 0.26 cm/year to 1.72 cm/year. The average value of the sedimentation rate obtained is 0.59 cm/year, and this rate has been compared with those resulting from the application of the 210Pb dating technique. A good agreement between the two procedures has been found. From the study carried out, it has been possible for the first time, to draw a map of sedimentation rates for this zone where numerous physical-chemical, oceanographic and ecological studies converge, since it is situated in a region of great environmental interest

  10. Application of non-radiometric methods to the determination of plutonium. Literature review conducted for the Buried Waste Integrated Program

    SciTech Connect

    Edelson, M.C.

    1992-03-05

    This literature review was motivated by discussions that took place during a review of contamination control technologies proposed for INEL (buried waste). It should be a useful tool in identifying non-radiation measurement techniques for Pu and Am such as ICP-MS, which should fulfill the following criteria: apparatus must be field deployable; up to 100 samples per day; and lower levels of detection and required time must be listed. The sensitivity of ICP and RIMS is compared against that needed for contamination monitoring at INEL. Only Pu-241, with a required detection limit of 400 ppt, would challenge the sensitivity of ICP-MS; Pu-238 would be easily determined. The need to determine Pu-238 and Am-241 in the presence of U-238 and Pu-241 seems to preclude the possibility of using laser ablation ICP-MS for Pu monitoring. ICP-AES and -LEAFS methods may not have enough sensitivity to determine Pu-238 at 2 ppb level with confidence, but RIMS (resonance ionization mass spectroscopy) should be adequate. 47 refs, figs.

  11. Radiometric measurement of metabolic activity of Mycobacterium lepraemurium.

    PubMed

    Camargo, E E; Larson, S M; Tepper, B S; Wagner, H N

    1974-09-01

    A sensitive and nondestructive radiometric method has been applied to the detection of metabolism of Mycobacterium lepraemurium, as a model for the study of the metabolism and substrate requirements of M. leprae. The method is based on the measurement of the (14)CO(2) produced through the bacterial conversion of [U-(14)C]acetate or [U-(14)C]glycerol by 7 x 10(9) bacteria suspended in 10 ml of either a simple buffer system (K-36) or a complex medium (NC-5). Metabolism of the bacilli was easily detected within 3 days after inoculation and was measured daily. NC-5 medium supported metabolism of M. lepraemurium for several weeks longer than the simple K-36 buffer. The radiometric technique shows promise as a rapid and efficient system for evaluating the metabolism of mycobacteria without introducing any changes in the physiologic state of the organisms, studying their metabolic pathways, determining conditions potentially favorable for multiplication of these organisms in vitro, and studying their susceptibility to inhibition by drugs.

  12. The radiometric characteristics of KOMPSAT-3A by using reference radiometric tarps and ground measurement

    NASA Astrophysics Data System (ADS)

    Yeom, Jong-Min

    2016-09-01

    In this study, we performed the vicarious radiometric calibration of KOMPSAT-3A multispectral bands by using 6S radiative transfer model, radiometric tarps, MFRSR measurements. Furthermore, to prepare the accurate input parameter, we also did experiment work to measure the BRDF of radiometric tarps based on hyperspectral gonioradiometer to compensate the observation geometry difference between satellite and ASD Fieldspec 3. Also, we measured point spread function (PSF) by using the bright star and corrected multispectral bands based on the Wiener filter. For accurate atmospheric constituent effects such as aerosol optical depth, column water, and total ozone, we used MFRSR instrument and estimated related optical depth of each gases. Based on input parameters for 6S radiative transfer model, we simulated top of atmosphere (TOA) radiance by observed by KOMPSAT-3A and matched-up the digital number. Consequently, DN to radiance coefficients was determined based on aforementioned methods and showed reasonable statistics results.

  13. Rapid Radiochemical Method for Plutonium-238 and ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Technique: Alpha spectrometry Method Developed for: Plutonium-238 and plutonium-239 in building materials Method Selected for: SAM lists this method for qualitative analysis of plutonium-238 and -239 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  14. Rapid field-screening method for PCBs

    NASA Astrophysics Data System (ADS)

    Vo-Dinh, Tuan; Watts, Wendi; Miller, Gordon H.; Pal, A.; Eastwood, DeLyle; Lidberg, Russell L.

    1993-03-01

    The analysis of polychlorinated biphenyls (PCBs) generally requires selectivity and sensitivity. Even after cleanup, PCBs are usually at ultratrace levels in field samples, mixed in with other halocarbons, hydrocarbons, lipids, etc. The levels of PCBs typically found in water, soil, tissue, food, biota, and other matrices of interest are in the parts per billion (ppb) range. Most current measurement techniques for PCBs require chromatographic separations and are not practical for routine analysis. There is a strong need to have rapid and simple techniques to screen for PCBs under field conditions. The use of field screening analysis allows rapid decisions in remedial actions and reduces the need for sample preparations and time- consuming laboratory analyses. Field screening techniques also reduce the cost of clean-up operations. This paper describes a simple screening technique based on room temperature phosphorescence (RTP) and provides an overview of both this analytical procedure to detect trace levels of PCBs in environmental samples.

  15. Radiometric detection of yeasts in blood cultures of cancer patients

    SciTech Connect

    Hopfer, R.L.; Orengo, A.; Chesnut, S.; Wenglar, M.

    1980-09-01

    During a 12-month period, 19,457 blood cultures were collected. Yeasts were isolated from 193 cultures derived from 76 cancer patients. Candida albicans or Candida tropicalis accounted for 79% of isolates. Of the three methods compared, the radiometric method required 2.9 days to become positive, blind subculture required 2.6 days, and Gram stains required 1 day. However, the radiometric method was clearly superior in detecting positive cultures, since 73% of all cultures were first detected radiometrically, 22% were detected by subculture, and only 5% were detected by Gram stain. Although 93% of the isolates were detected by aerobic culture, five (7%) isolates were obtained only from anaerobic cultures. Seven days of incubation appear to be sufficient for the radiometric detection of yeasts.

  16. Use of a novel radiometric method to assess the inhibitory effect of donepezil on acetylcholinesterase activity in minimally diluted tissue samples

    PubMed Central

    Kikuchi, Tatsuya; Okamura, Toshimitsu; Arai, Takuya; Obata, Takayuki; Fukushi, Kiyoshi; Irie, Toshiaki; Shiraishi, Tetsuya

    2010-01-01

    Background and purpose: Cholinesterase inhibitors have been widely used for the treatment of patients with dementia. Monitoring of the cholinesterase activity in the blood is used as an indicator of the effect of the cholinesterase inhibitors in the brain. The selective measurement of cholinesterase with low tissue dilution is preferred for accurate monitoring; however, the methods have not been established. Here, we investigated the effect of tissue dilution on the action of cholinesterase inhibitors using a novel radiometric method with selective substrates, N-[14C]methylpiperidin-4-yl acetate ([14C]MP4A) and (R)-N-[14C]methylpiperidin-3-yl butyrate ([14C]MP3B_R), for AChE and butyrylcholinesterase (BChE) respectively. Experimental approach: We investigated the kinetics of hydrolysis of [14C]-MP4A and [14C]-MP3B_R by cholinesterases, and evaluated the selectivity of [14C]MP4A and [14C]MP3B_R for human AChE and BChE, respectively, compared with traditional substrates. Then, IC50 values of cholinesterase inhibitors in minimally diluted and highly diluted tissues were measured with [14C]MP4A and [14C]MP3B_R. Key results: AChE and BChE activities were selectively measured as the first-order hydrolysis rates of [14C]-MP4A and [14C]MP3B_R respectively. The AChE selectivity of [14C]MP4A was an order of magnitude higher than traditional substrates used for the AChE assay. The IC50 values of specific AChE and BChE inhibitors, donepezil and ethopropazine, in 1.2-fold diluted human whole blood were much higher than those in 120-fold diluted blood. In addition, the IC50 values of donepezil in monkey brain were dramatically decreased as the tissue was diluted. Conclusions and implications: This method would effectively monitor the activity of cholinesterase inhibitors used for therapeutics, pesticides and chemical warfare agents. PMID:20401964

  17. Improved detection of Mycobacterium avium complex with the Bactec radiometric system

    SciTech Connect

    Hoffner, S.E.

    1988-05-01

    A reconsideration of the laboratory methods used for primary isolation of mycobacteria other than Mycobacterium tuberculosis is needed due to the increasingly recognized importance of such mycobacterial infections in immunocompromised patients. One example of this is the severe opportunistic infections caused by Mycobacterium avium complex among AIDS patients. In this study, the Bactec radiometric system was compared to conventional culture on solid medium for the detection of M. avium complex in 3,612 selected clinical specimens, mainly of extrapulmonary origin. Of a total number of 63 M. avium complex isolates, the Bactec system detected 58 (92%), compared to 37 (59%) for conventional culture. A much more rapid detection was attained with radiometric technique than with conventional culture. The mean detection time for the cultures positive with both methods was 7.1 and 28.3 days, respectively. The Bactec radiometric system achieves a rapid and significantly more sensitive detection and seems to be an excellent complement to conventional culture in the laboratory diagnosis of infections with the M. avium complex.

  18. Verification of the radiometric map of the Czech Republic.

    PubMed

    Matolín, Milan

    2017-01-01

    The radiometric map of the Czech Republic is based on uniform regional airborne radiometric total count measurements (1957-1959) which covered 100% of the country. The airborne radiometric instrument was calibrated to a (226)Ra point source. The calibration facility for field gamma-ray spectrometers, established in the Czech Republic in 1975, significantly contributed to the subsequent radiometric data standardization. In the 1990's, the original analogue airborne radiometric data were digitized and using the method of back-calibration (IAEA, 2003) converted to dose rate. The map of terrestrial gamma radiation expressed in dose rate (nGy/h) was published on the scale 1:500,000 in 1995. Terrestrial radiation in the Czech Republic, formed by magmatic, sedimentary and metamorphic rocks of Proterozoic to Quaternary age, ranges mostly from 6 to 245 nGy/h, with a mean of 65.6 ± 19.0 nGy/h. The elevated terrestrial radiation in the Czech Republic, in comparison to the global dose rate average of 54 nGy/h, reflects an enhanced content of natural radioactive elements in the rocks. The 1995 published radiometric map of the Czech Republic was successively studied and verified by additional ground gamma-ray spectrometric measurements and by comparison to radiometric maps of Germany, Poland and Slovakia in border zones. A ground dose rate intercomparison measurement under participation of foreign and domestic professional institutions revealed mutual dose rate deviations about 20 nGy/h and more due to differing technical parameters of applied radiometric instruments. Studies and verification of the radiometric map of the Czech Republic illustrate the magnitude of current deviations in dose rate data. This gained experience can assist in harmonization of dose rate data on the European scale. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Non-invasive hyperthermia apparatus including coaxial applicator having a non-invasive radiometric receiving antenna incorporated therein and method of use thereof

    DOEpatents

    Ross, Michael P.

    1996-01-01

    A coaxial hyperthermia applicator for applying non-invasively electromagnetic energy to a body against which it is placed. The coaxial applicator antenna has formed integrally within it a non-invasive radiometric antenna for receiving thermoelectromagnetic emissions. The coaxial-configured applicator produces a bell-shaped radiation pattern symmetric about the axis of symmetry of the coaxial applicator. Integrating the radiometric antenna within the coaxial applicator produces a single device that performs dual functions. The first function is to transmit non-invasively energy for heating a subcutaneous tumor. The second function is to receive non-invasively thermal electromagnetic radiation from the tumor by which temperature is sensed and fed back to control the output of the coaxial applicator.

  20. Non-invasive hyperthermia apparatus including coaxial applicator having a non-invasive radiometric receiving antenna incorporated therein and method of use thereof

    DOEpatents

    Ross, M.P.

    1996-08-27

    A coaxial hyperthermia applicator is disclosed for applying non-invasively electromagnetic energy to a body against which it is placed. The coaxial applicator antenna has formed integrally within it a non-invasive radiometric antenna for receiving thermoelectromagnetic emissions. The coaxial-configured applicator produces a bell-shaped radiation pattern symmetric about the axis of symmetry of the coaxial applicator. Integrating the radiometric antenna within the coaxial applicator produces a single device that performs dual functions. The first function is to transmit non-invasively energy for heating a subcutaneous tumor. The second function is to receive non-invasively thermal electromagnetic radiation from the tumor by which temperature is sensed and fed back to control the output of the coaxial applicator. 11 figs.

  1. Radiometric and Spectral Measurement Instruments

    DTIC Science & Technology

    1992-03-18

    NSWCCR/RDTN-92/0003 AD-A250 771LI~ llliii11l li l l iillt111 RADIOMETRIC AND SPECTRAL MEASUREMENT INSTRUMENTS CRANE DIVISION NAVAL SURFACE WARFARE... INSTRUMENTS 6. AUTHOR(S) B. E. DOUDA H. A. WEBSTER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) a. PERFORMING ORGANIZATION REPORT NIJMBER...Maxiry-um 200 w ords) THIS IS A DESCRIPTION OF AN ASSORTMENT OF RADIOMETRIC AND SPECTRAL INSTRUMENTATION USED FOR MEASUREMENT OF THE RADIATIVE OUTPUT OF

  2. Radiometric Navigation Update

    NASA Astrophysics Data System (ADS)

    Nettles, James L.; Witsmeer, A. James; Wilt, Robert E.

    1980-12-01

    Boeing Aerospace Company (BAC) of Seattle, Washington and Sperry Microwave Electronics of Clearwater, Florida have developed a multiple-beam radiometric navigation update system. This paper describes the system design, flight test program, and preliminary results. The system was designed and its performance evaluated using analytically derived formulas for performance measures and detailed Monte Carlo simulations. As a result BAC recommended a five or seven fixed beam radiometer. Sperry built a seven-beam, 35 GHz radiometer which BAC flight tested in 1979 to demonstrate its effectiveness over a variety of test scenes under various environmental conditions. Four scenes were selected for the flight test varying from land-water to highly forested regions. Preliminary analysis of the flight test results confirm the expected performance improvement over the single-fixed-beam system tested in 1975. This approach to a terrain sensing millimeter wave radiometer would be applicable to low altitude penetrating aircraft. The system is low cost, with no moving parts; low volume, requiring only a single receiver with small wide-beam antennas; and stealthy, being completely passive. Radiometry can also be complementary to todays terrain correlation approach since flat areas usually contain a maximum of cultural features; where one system works poorly the other works well. This test program provides a data base for studying a wide variety of pattern matching and correlation algorithms, with and without attitude compensation, and using various subsets of the full seven-beam combination.

  3. Methods and compositions for rapid thermal cycling

    DOEpatents

    Beer, Neil Reginald; Benett, William J.; Frank, James M.; Deotte, Joshua R.; Spadaccini, Christopher

    2015-10-27

    The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.

  4. Method for rapid isolation of sensitive mutants

    DOEpatents

    Freyer, James P.

    1997-01-01

    Sensitive mammalian cell mutants are rapidly isolated using flow cytometry. A first population of clonal spheroids is established to contain both normal and mutant cells. The population may be naturally occurring or may arise from mutagenized cells. The first population is then flow sorted by size to obtain a second population of clonal spheroids of a first uniform size. The second population is then exposed to a DNA-damaging agent that is being investigated. The exposed second population is placed in a growth medium to form a third population of clonal spheroids comprising spheroids of increased size from the mammalian cells that are resistant to the DNA-damaging agent and spheroids of substantially the first uniform size formed from the mammalian cells that are sensitive to the DNA-damaging agent. The third population is not flow sorted to differentiate the spheroids formed from resistant mammalian cells from spheroids formed from sensitive mammalian cells. The spheroids formed from sensitive mammalian cells are now treated to recover viable sensitive cells from which a sensitive cell line can be cloned.

  5. Method for rapid isolation of sensitive mutants

    DOEpatents

    Freyer, J.P.

    1997-07-29

    Sensitive mammalian cell mutants are rapidly isolated using flow cytometry. A first population of clonal spheroids is established to contain both normal and mutant cells. The population may be naturally occurring or may arise from mutagenized cells. The first population is then flow sorted by size to obtain a second population of clonal spheroids of a first uniform size. The second population is then exposed to a DNA-damaging agent that is being investigated. The exposed second population is placed in a growth medium to form a third population of clonal spheroids comprising spheroids of increased size from the mammalian cells that are resistant to the DNA-damaging agent and spheroids of substantially the first uniform size formed from the mammalian cells that are sensitive to the DNA-damaging agent. The third population is not flow sorted to differentiate the spheroids formed from resistant mammalian cells from spheroids formed from sensitive mammalian cells. The spheroids formed from sensitive mammalian cells are now treated to recover viable sensitive cells from which a sensitive cell line can be cloned. 15 figs.

  6. Uncooled radiometric camera performance

    NASA Astrophysics Data System (ADS)

    Meyer, Bill; Hoelter, T.

    1998-07-01

    Thermal imaging equipment utilizing microbolometer detectors operating at room temperature has found widespread acceptance in both military and commercial applications. Uncooled camera products are becoming effective solutions to applications currently using traditional, photonic infrared sensors. The reduced power consumption and decreased mechanical complexity offered by uncooled cameras have realized highly reliable, low-cost, hand-held instruments. Initially these instruments displayed only relative temperature differences which limited their usefulness in applications such as Thermography. Radiometrically calibrated microbolometer instruments are now available. The ExplorIR Thermography camera leverages the technology developed for Raytheon Systems Company's first production microbolometer imaging camera, the Sentinel. The ExplorIR camera has a demonstrated temperature measurement accuracy of 4 degrees Celsius or 4% of the measured value (whichever is greater) over scene temperatures ranges of minus 20 degrees Celsius to 300 degrees Celsius (minus 20 degrees Celsius to 900 degrees Celsius for extended range models) and camera environmental temperatures of minus 10 degrees Celsius to 40 degrees Celsius. Direct temperature measurement with high resolution video imaging creates some unique challenges when using uncooled detectors. A temperature controlled, field-of-view limiting aperture (cold shield) is not typically included in the small volume dewars used for uncooled detector packages. The lack of a field-of-view shield allows a significant amount of extraneous radiation from the dewar walls and lens body to affect the sensor operation. In addition, the transmission of the Germanium lens elements is a function of ambient temperature. The ExplorIR camera design compensates for these environmental effects while maintaining the accuracy and dynamic range required by today's predictive maintenance and condition monitoring markets.

  7. Rapid Methods for Estimating Navigation Channel Shoaling

    DTIC Science & Technology

    2009-01-01

    of the data dependence and lack of accounting for channel width. Mayor- Mora et al. (1976) developed an analytical method for infilling in a...1.2 cm/day near the end of the monitoring. The predictive expression of Mayor- Mora et al. (1976) is: /(1 ) (1 ) cosa dFh h FR in hdq q e q e...decision-support or initial planning studies that must be done quickly. Vicente and Uva (1984) present a method based on the assumption that a

  8. Rapid vegetative propagation method for carob

    USDA-ARS?s Scientific Manuscript database

    Many fruit species are propagated by vegetative methods such as budding, grafting, cutting, suckering, layering etc. to avoid heterozygosity. Carob trees (Ceratonia siliqua L.) are of highly economical value and it is among the most difficult-to-propagate fruit species. In this study, air-layering p...

  9. Radiometric age map of southwest Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  10. Radiometric age map of southcentral Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  11. Radiometric age map of northern Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  12. Radiometric age map of Aleutian Islands

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  13. Radiometric age map of southeast Alaska

    USGS Publications Warehouse

    Wilson, Frederic H.; Turner, D.L.

    1975-01-01

    This map includes published, thesis, and open-file radiometric data available to us as of June, 1975. Some dates are not plotted because of inadequate location data in the original references.The map is divided into five sections, based on 1:1,000,000 scale enlargements of the National Atlas maps of Alaska. Within each section (e.g., southeastern Alaska), radiometric dates are plotted and keyed to 1:250,000 scale quadrangles. Accompanying each map section is table 1, listing map numbers and the sample identification numbers used in DGGS Special Report 10: Radiometric Dates from Alaska-A 1975 Compilation”. The reader is referred to Special Report 10 for more complete information on location, rock type, dating method, and literature references for each age entry. A listing of dates in Special Report lo which require correction or deletion is included S table 2. Corrected and additional entries are listed in table 3. The listings in tables 2 and 3 follow the format of Special Report 10. Table 4 is a glossary of abbreviations used for quadrangle name, rock type, mineral dated, and type of dating method used.

  14. Method and system rapid piece handling

    DOEpatents

    Spletzer, Barry L.

    1996-01-01

    The advent of high-speed fabric cutters has made necessary the development of automated techniques for the collection and sorting of garment pieces into collated piles of pieces ready for assembly. The present invention enables a new method for such handling and sorting of garment parts, and to apparatus capable of carrying out this new method. The common thread is the application of computer-controlled shuttling bins, capable of picking up a desired piece of fabric and dropping it in collated order for assembly. Such apparatus with appropriate computer control relieves the bottleneck now presented by the sorting and collation procedure, thus greatly increasing the overall rate at which garments can be assembled.

  15. Method for large and rapid terahertz imaging

    DOEpatents

    Williams, Gwyn P.; Neil, George R.

    2013-01-29

    A method of large-scale active THz imaging using a combination of a compact high power THz source (>1 watt), an optional optical system, and a camera for the detection of reflected or transmitted THz radiation, without the need for the burdensome power source or detector cooling systems required by similar prior art such devices. With such a system, one is able to image, for example, a whole person in seconds or less, whereas at present, using low power sources and scanning techniques, it takes several minutes or even hours to image even a 1 cm.times.1 cm area of skin.

  16. Lansat MSS, Radiometric Processing Improvement

    NASA Astrophysics Data System (ADS)

    Saunier, Sebastien; Salgues, Germain; Gascon, Ferran; Biaasutti, Roberto

    2016-08-01

    The reprocessing campaigns of Landsat European Space Agency (ESA) data archive have been initiated since 3 years [1]. As part of this project, the processing algorithms have been upgraded. This article focuses on the radiometric processing of historical data observed with the Multi Spectral Scanner (MSS) instruments on board Landsat 1, 2, 3, 4 and 5.The Landsat MSS data have been recorded data from 1972 up to 1990. The MSS instruments have been designed with four visible bands covering the near / infrared regions of the electromagnetic spectrum, allowing the spatial sampling of our Earth surface at 60 meter.The current calibration method has shown some limitations in case of data observed out of mid latitude areas, where the Earth surface is bright because of desert or snow. The resulting image data suffers from saturations and is not fit for the potential application purposes.Although, when saturation exist, further investigations have shown that the radiometry of the raw data involved in the production of the Level 1 images is generally correct. As consequences, experiments have been undertaken to adapt the current processing in order to produce image data saturation free products.

  17. Advances in rapid detection methods for foodborne pathogens.

    PubMed

    Zhao, Xihong; Lin, Chii-Wann; Wang, Jun; Oh, Deog Hwan

    2014-03-28

    Food safety is increasingly becoming an important public health issue, as foodborne diseases present a widespread and growing public health problem in both developed and developing countries. The rapid and precise monitoring and detection of foodborne pathogens are some of the most effective ways to control and prevent human foodborne infections. Traditional microbiological detection and identification methods for foodborne pathogens are well known to be time consuming and laborious as they are increasingly being perceived as insufficient to meet the demands of rapid food testing. Recently, various kinds of rapid detection, identification, and monitoring methods have been developed for foodborne pathogens, including nucleic-acid-based methods, immunological methods, and biosensor-based methods, etc. This article reviews the principles, characteristics, and applications of recent rapid detection methods for foodborne pathogens.

  18. Rapid Method for Sodium Hydroxide/Sodium Peroxide Fusion ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Plutonium-238 and plutonium-239 in water and air filters Method Selected for: SAM lists this method as a pre-treatment technique supporting analysis of refractory radioisotopic forms of plutonium in drinking water and air filters using the following qualitative techniques: • Rapid methods for acid or fusion digestion • Rapid Radiochemical Method for Plutonium-238 and Plutonium 239/240 in Building Materials for Environmental Remediation Following Radiological Incidents. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  19. A recreation quality rapid assessment method for visitor capacity management

    Treesearch

    Kenneth Chilman; Stuart Schneider; Les Wadzinski

    2007-01-01

    A rapid assessment method for inexpensively obtaining representative samples of place-specific visitor numbers and perceptions of visit quality was tested on Niobrara National Scenic River (NSR). Similar tests have been done on national forest areas in Indiana and Illinois. The data are used in meetings focusing on visitor capacity management. The rapid assessment...

  20. Radiometric surveys in underground environment

    NASA Astrophysics Data System (ADS)

    Bochiolo, Massimo; Chiozzi, Paolo; Verdoya, Massimo; Pasquale, Vincenzo

    2010-05-01

    Due to their ability to travel through the air for several metres, gamma-rays emitted from natural radioactive elements can be successfully used in surveys carried out both with airborne and ground equipments. Besides the concentration of the radio-elements contained in rocks and soils and the intrinsic characteristics of the gamma-ray detector, the detected count rate depends on the solid angle around the spectrometer. On a flat outcrop, ground spectrometry detects the radiation ideally produced by a cylindrical mass of rock of about two metres in diameter and thickness of about half a meter. Under these geometrical conditions, the natural radioactivity can be easily evaluated. With operating conditions different from the standard ones, such as at the edge of an escarpment, the count rate halves because of the missing material, whereas in the vicinity of a rock wall the count rate will increase. In underground environment, the recorded count rate may even double and the in situ assessment of the concentration of radio-elements may be rather difficult, even if the ratios between the different radio-elements may not be affected. We tested the applicability of gamma-ray spectrometry for rapid assessment of the potential hazard levels related to radon and radiation dose rate in underground environment. A mine shaft, located in a zone of uranium enrichment in Liguria (Italy), has been investigated. A preliminary ground radiometric survey was carried out to define the extent of the ore deposit. Then, the radiometric investigation was focussed on the mine shaft. Due to rock mass above the shaft vault, the background gamma radiation can be considered of negligible influence on measurements. In underground surveys, besides deviations from a flat geometry, factors controlling radon exhalation, emanation and stagnation, such as fractures, water leakage and the presence of ventilation, should be carefully examined. We attempted to evaluate these control factors and collected

  1. Predictions for rapid methods and automation in food microbiology.

    PubMed

    Fung, Daniel Y C

    2002-01-01

    A discussion is presented on the present status of rapid methods and automation in microbiology. Predictions are also presented for development in the following areas: viable cell counts; real-time monitoring of hygiene; polymerase chain reaction, ribotyping, and genetic tests in food laboratories; automated enzyme-linked immunosorbent assay and immunotests; rapid dipstick technology; biosensors for Hazard Analysis Critical Control Point programs; instant detection of target pathogens by computer-generated matrix; effective separation and concentration for rapid identification of target cells; microbiological alert systems in food packages; and rapid alert kits for detecting pathogens at home.

  2. [A new method of fabricating photoelastic model by rapid prototyping].

    PubMed

    Fan, Li; Huang, Qing-feng; Zhang, Fu-qiang; Xia, Yin-pei

    2011-10-01

    To explore a novel method of fabricating the photoelastic model using rapid prototyping technique. A mandible model was made by rapid prototyping with computerized three-dimensional reconstruction, then the photoelastic model with teeth was fabricated by traditional impression duplicating and mould casting. The photoelastic model of mandible with teeth, which was fabricated indirectly by rapid prototyping, was very similar to the prototype in geometry and physical parameters. The model was of high optical sensibility and met the experimental requirements. Photoelastic model of mandible with teeth indirectly fabricated by rapid prototyping meets the photoelastic experimental requirements well.

  3. Expediting systematic reviews: methods and implications of rapid reviews

    PubMed Central

    2010-01-01

    Background Policy makers and others often require synthesis of knowledge in an area within six months or less. Traditional systematic reviews typically take at least 12 months to conduct. Rapid reviews streamline traditional systematic review methods in order to synthesize evidence within a shortened timeframe. There is great variation in the process of conducting rapid reviews. This review sought to examine methods used for rapid reviews, as well as implications of methodological streamlining in terms of rigour, bias, and results. Methods A comprehensive search strategy--including five electronic databases, grey literature, hand searching of relevant journals, and contacting key informants--was undertaken. All titles and abstracts (n = 1,989) were reviewed independently by two reviewers. Relevance criteria included articles published between 1995 and 2009 about conducting rapid reviews or addressing comparisons of rapid reviews versus traditional reviews. Full articles were retrieved for any titles deemed relevant by either reviewer (n = 70). Data were extracted from all relevant methodological articles (n = 45) and from exemplars of rapid review methods (n = 25). Results Rapid reviews varied from three weeks to six months; various methods for speeding up the process were employed. Some limited searching by years, databases, language, and sources beyond electronic searches. Several employed one reviewer for title and abstract reviewing, full text review, methodological quality assessment, and/or data extraction phases. Within rapid review studies, accelerating the data extraction process may lead to missing some relevant information. Biases may be introduced due to shortened timeframes for literature searching, article retrieval, and appraisal. Conclusions This review examined the continuum between diverse rapid review methods and traditional systematic reviews. It also examines potential implications of streamlined review methods. More of these rapid reviews need

  4. Optical Imaging and Radiometric Modeling and Simulation

    NASA Technical Reports Server (NTRS)

    Ha, Kong Q.; Fitzmaurice, Michael W.; Moiser, Gary E.; Howard, Joseph M.; Le, Chi M.

    2010-01-01

    OPTOOL software is a general-purpose optical systems analysis tool that was developed to offer a solution to problems associated with computational programs written for the James Webb Space Telescope optical system. It integrates existing routines into coherent processes, and provides a structure with reusable capabilities that allow additional processes to be quickly developed and integrated. It has an extensive graphical user interface, which makes the tool more intuitive and friendly. OPTOOL is implemented using MATLAB with a Fourier optics-based approach for point spread function (PSF) calculations. It features parametric and Monte Carlo simulation capabilities, and uses a direct integration calculation to permit high spatial sampling of the PSF. Exit pupil optical path difference (OPD) maps can be generated using combinations of Zernike polynomials or shaped power spectral densities. The graphical user interface allows rapid creation of arbitrary pupil geometries, and entry of all other modeling parameters to support basic imaging and radiometric analyses. OPTOOL provides the capability to generate wavefront-error (WFE) maps for arbitrary grid sizes. These maps are 2D arrays containing digital sampled versions of functions ranging from Zernike polynomials to combination of sinusoidal wave functions in 2D, to functions generated from a spatial frequency power spectral distribution (PSD). It also can generate optical transfer functions (OTFs), which are incorporated into the PSF calculation. The user can specify radiometrics for the target and sky background, and key performance parameters for the instrument s focal plane array (FPA). This radiometric and detector model setup is fairly extensive, and includes parameters such as zodiacal background, thermal emission noise, read noise, and dark current. The setup also includes target spectral energy distribution as a function of wavelength for polychromatic sources, detector pixel size, and the FPA s charge

  5. REVIEW OF RAPID METHODS FOR ASSESSING WETLAND CONDITION

    EPA Science Inventory

    We evaluated over 40 wetland rapid assessment methods developed for a variety of purposes for their use in the assessment of ecological integrity or ecosystem condition. Four criteria were used to screen methods: 1) the method can be used to measure condition, 2) it is truly rap...

  6. REVIEW OF RAPID METHODS FOR ASSESSING WETLAND CONDITION

    EPA Science Inventory

    We evaluated over 40 wetland rapid assessment methods developed for a variety of purposes for their use in the assessment of ecological integrity or ecosystem condition. Four criteria were used to screen methods: 1) the method can be used to measure condition, 2) it is truly rap...

  7. RAPID METHOD FOR DETERMINATION OF RADIOSTRONTIUM IN EMERGENCY MILK SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-07-17

    A new rapid separation method for radiostrontium in emergency milk samples was developed at the Savannah River Site (SRS) Environmental Bioassay Laboratory (Aiken, SC, USA) that will allow rapid separation and measurement of Sr-90 within 8 hours. The new method uses calcium phosphate precipitation, nitric acid dissolution of the precipitate to coagulate residual fat/proteins and a rapid strontium separation using Sr Resin (Eichrom Technologies, Darien, IL, USA) with vacuum-assisted flow rates. The method is much faster than previous method that use calcination or cation exchange pretreatment, has excellent chemical recovery, and effectively removes beta interferences. When a 100 ml sample aliquot is used, the method has a detection limit of 0.5 Bq/L, well below generic emergency action levels.

  8. Rapid methods for detection of bacterial resistance to antibiotics.

    PubMed

    March-Rosselló, Gabriel Alberto

    2017-03-01

    The most widely used antibiotic susceptibility testing methods in Clinical Microbiology are based on the phenotypic detection of antibiotic resistance by measuring bacterial growth in the presence of the antibiotic being tested. These conventional methods take typically 24hours to obtain results. Here we review the main techniques for rapid determination of antibiotic susceptibility. Data obtained with different methods such as molecular techniques, microarrays, commercial methods used in work routine, immunochromatographic methods, colorimetric methods, image methods, nephelometry, MALDI-TOF mass spectrometry, flow cytometry, chemiluminescence and bioluminescence, microfluids and methods based on cell disruption are analysed in detail.

  9. Rapid Method for Sodium Hydroxide Fusion of Asphalt ...

    EPA Pesticide Factsheets

    Technical Brief--Addendum to Selected Analytical Methods (SAM) 2012 Rapid method developed for analysis of Americium-241 (241Am), plutonium-238 (238Pu), plutonium-239 (239Pu), radium-226 (226Ra), strontium-90 (90Sr), uranium-234 (234U), uranium-235 (235U) and uranium-238 (238U) in asphalt roofing material samples

  10. A rapid ultrasound particle agglutination method for HIV antibody detection: Comparison with conventional rapid HIV tests.

    PubMed

    Bystryak, Simon; Ossina, Natalya

    2017-08-24

    We present the results of the feasibility and preliminary studies on analytical performance of a rapid test for detection of human immunodeficiency virus (HIV) antibodies in human serum or plasma that is an important advance in detecting HIV infection. Current methods for rapid testing of antibodies against HIV are qualitative and exhibit poor sensitivity (limit of detection). In this paper, we describe an ultrasound particle agglutination (UPA) method that leads to a significant increase of the sensitivity of conventional latex agglutination tests for HIV antibody detection in human serum or plasma. The UPA method is based on the use of: 1) a dual mode ultrasound, wherein a first single-frequency mode is used to accelerate the latex agglutination process, and then a second swept-frequency mode of sonication is used to disintegrate non-specifically bound aggregates; and 2) a numerical assessment of results of the agglutination process. The numerical assessment is carried out by optical detection and analysis of moving patterns in the resonator cell during the swept-frequency mode. The single-step UPA method is rapid and more sensitive than the three commercial rapid HIV test kits analyzed in the study: analytical sensitivity of the new UPA method was found to be 510-, 115-, and 80-fold higher than that for Capillus™, Multispot™ and Uni-Gold™ Recombigen HIV antibody rapid test kits, respectively. The newly developed UPA method opens up additional possibilities for detection of a number of clinically significant markers in point-of-care settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Methods and systems for rapid prototyping of high density circuits

    SciTech Connect

    Palmer, Jeremy A.; Davis, Donald W.; Chavez, Bart D.; Gallegos, Phillip L.; Wicker, Ryan B.; Medina, Francisco R.

    2008-09-02

    A preferred embodiment provides, for example, a system and method of integrating fluid media dispensing technology such as direct-write (DW) technologies with rapid prototyping (RP) technologies such as stereolithography (SL) to provide increased micro-fabrication and micro-stereolithography. A preferred embodiment of the present invention also provides, for example, a system and method for Rapid Prototyping High Density Circuit (RPHDC) manufacturing of solderless connectors and pilot devices with terminal geometries that are compatible with DW mechanisms and reduce contact resistance where the electrical system is encapsulated within structural members and manual electrical connections are eliminated in favor of automated DW traces. A preferred embodiment further provides, for example, a method of rapid prototyping comprising: fabricating a part layer using stereolithography and depositing thermally curable media onto the part layer using a fluid dispensing apparatus.

  12. Radiometric normalization with multi-image pseudo-invariant features

    NASA Astrophysics Data System (ADS)

    Barazzetti, Luigi; Gianinetto, Marco; Scaioni, Marco

    2016-08-01

    Radiometric image normalization is one of the basic pre-processing methods used in satellite time series analysis. This paper presents a new multi-image approach able to estimate the parameters of relative radiometric normalization through a multiple and simultaneous regression with a dataset of a generic number of images. The method was developed to overcome the typical drawbacks of standard one-to-one techniques, where image pairs are independently processed. The proposed solution is based on multi-image pseudo-invariant features incorporated into a unique regression solved via Least Squares. Results for both simulated and real data are presented and discussed.

  13. Rapid methods and computer assisted diagnosis in medical microbiology.

    PubMed

    Heizmann, W R

    1991-01-01

    Rapid diagnosis and reporting in medical microbiology is becoming more and more important. In recent years, introduction of automated instruments as well as of computer assisted diagnosis contributed to this aim. These methods, however, are very expensive. A more cost efficient and simple to perform method for rapid diagnosis is the use of specific fluorogenic substrates incorporated into culture media (solid or liquid) for identification of the most important pathogens, e.g. Escherichia coli. Investigation of Fluorocult ECD agar and Columbia agar revealed a high sensitivity (85%) and an excellent specificity (greater than 99%) of fluorescence in combination with a positive indole reaction for identification of E. coli.

  14. Absolute Radiometric Calibration of KOMPSAT-3A

    NASA Astrophysics Data System (ADS)

    Ahn, H. Y.; Shin, D. Y.; Kim, J. S.; Seo, D. C.; Choi, C. U.

    2016-06-01

    This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A) performed by the Korea Aerospace Research Institute (KARI) and the Pukyong National University Remote Sensing Group (PKNU RSG) in 2015.The primary stages of this study are summarized as follows: (1) A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2) To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4). Correlations between top-of-atmosphere (TOA) radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB) region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  15. Radiometric Dating in Geology.

    ERIC Educational Resources Information Center

    Pankhurst, R. J.

    1980-01-01

    Described are several aspects and methods of quantitatively measuring geologic time using a constant-rate natural process of radioactive decay. Topics include half lives and decay constants, radiogenic growth, potassium-argon dating, rubidium-strontium dating, and the role of geochronology in support of geological exploration. (DS)

  16. Radiometric Dating in Geology.

    ERIC Educational Resources Information Center

    Pankhurst, R. J.

    1980-01-01

    Described are several aspects and methods of quantitatively measuring geologic time using a constant-rate natural process of radioactive decay. Topics include half lives and decay constants, radiogenic growth, potassium-argon dating, rubidium-strontium dating, and the role of geochronology in support of geological exploration. (DS)

  17. Use of radiometric ((234/238)U and (228/226)Ra) and mass spectrometry ((87/86)Sr) methods for studies of the stability of groundwater reservoirs in Central Poland.

    PubMed

    Grabowski, P; Bem, H; Romer, R L

    The uranium ((234)U/(238)U) and radium ((228)Ra/(226)Ra) activity ratios and (87)Sr/(86)Sr isotopic ratio in thermal groundwater, subsurface water (groundwater) and river water from Poddebice and Uniejow were determined. The uranium and radium activity ratios and strontium isotopic ratio varied from 0.629 to 1.471, from 0.396 to 4.961 and from 0.708438 to 0.710344, respectively. The results for the thermal groundwater samples showed that the radiometric method together with mass spectrometry stable strontium isotope ratio measurements can be used for underground water transport studies. On the basis of the uranium and radium activity and the strontium isotopic ratio differences in subsurface water (groundwater) and in river water, any possible water influx between these adjacent reservoirs can be observed. The obtained results exclude any water transport from surface and subsurface water to thermal ground water reservoirs in this region of Poland.

  18. Landsat-5 TM reflective-band absolute radiometric calibration

    USGS Publications Warehouse

    Chander, G.; Helder, D.L.; Markham, B.L.; Dewald, J.D.; Kaita, E.; Thome, K.J.; Micijevic, E.; Ruggles, T.A.

    2004-01-01

    The Landsat-5 Thematic Mapper (TM) sensor provides the longest running continuous dataset of moderate spatial resolution remote sensing imagery, dating back to its launch in March 1984. Historically, the radiometric calibration procedure for this imagery used the instrument's response to the Internal Calibrator (IC) on a scene-by-scene basis to determine the gain and offset of each detector. Due to observed degradations in the IC, a new procedure was implemented for U.S.-processed data in May 2003. This new calibration procedure is based on a lifetime radiometric calibration model for the instrument's reflective bands (1-5 and 7) and is derived, in part, from the IC response without the related degradation effects and is tied to the cross calibration with the Landsat-7 Enhanced Thematic Mapper Plus. Reflective-band absolute radiometric accuracy of the instrument tends to be on the order of 7% to 10%, based on a variety of calibration methods.

  19. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY SOIL SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.; Noyes, G.

    2009-11-09

    A new rapid method for the determination of actinides in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for samples up to 2 grams in emergency response situations. The actinides in soil method utilizes a rapid sodium hydroxide fusion method, a lanthanum fluoride soil matrix removal step, and a streamlined column separation process with stacked TEVA, TRU and DGA Resin cartridges. Lanthanum was separated rapidly and effectively from Am and Cm on DGA Resin. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha sources are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency soil samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinides in soil results were reported within 4-5 hours with excellent quality.

  20. Compact radiometric microwave calibrator

    SciTech Connect

    Fixsen, D. J.; Wollack, E. J.; Kogut, A.; Limon, M.; Mirel, P.; Singal, J.; Fixsen, S. M.

    2006-06-15

    The calibration methods for the ARCADE II instrument are described and the accuracy estimated. The Steelcast coated aluminum cones which comprise the calibrator have a low reflection while maintaining 94% of the absorber volume within 5 mK of the base temperature (modeled). The calibrator demonstrates an absorber with the active part less than one wavelength thick and only marginally larger than the mouth of the largest horn and yet black (less than -40 dB or 0.01% reflection) over five octaves in frequency.

  1. Evaluation of computational radiometric and spectral sensor calibration techniques

    NASA Astrophysics Data System (ADS)

    Manakov, Alkhazur

    2016-04-01

    Radiometric and spectral calibration are essential for enabling the use of digital sensors for measurement purposes. Traditional optical calibration techniques require expensive equipment such as specialized light sources, monochromators, tunable filters, calibrated photo-diodes, etc. The trade-offs between computational and physics-based characterization schemes are, however, not well understood. In this paper we perform an analysis of existing computational calibration schemes and elucidate their weak points. We highlight the limitations by comparing against ground truth measurements performed in an optical characterization laboratory (EMVA 1288 standard). Based on our analysis, we present accurate and affordable methods for the radiometric and spectral calibration of a camera.

  2. Rapid-estimation method for assessing scour at highway bridges

    USGS Publications Warehouse

    Holnbeck, Stephen R.

    1998-01-01

    A method was developed by the U.S. Geological Survey for rapid estimation of scour at highway bridges using limited site data and analytical procedures to estimate pier, abutment, and contraction scour depths. The basis for the method was a procedure recommended by the Federal Highway Administration for conducting detailed scour investigations, commonly referred to as the Level 2 method. Using pier, abutment, and contraction scour results obtained from Level 2 investigations at 122 sites in 10 States, envelope curves and graphical relations were developed that enable determination of scour-depth estimates at most bridge sites in a matter of a few hours. Rather than using complex hydraulic variables, surrogate variables more easily obtained in the field were related to calculated scour-depth data from Level 2 studies. The method was tested by having several experienced individuals apply the method in the field, and results were compared among the individuals and with previous detailed analyses performed for the sites. Results indicated that the variability in predicted scour depth among individuals applying the method generally was within an acceptable range, and that conservatively greater scour depths generally were obtained by the rapid-estimation method compared to the Level 2 method. The rapid-estimation method is considered most applicable for conducting limited-detail scour assessments and as a screening tool to determine those bridge sites that may require more detailed analysis. The method is designed to be applied only by a qualified professional possessing knowledge and experience in the fields of bridge scour, hydraulics, and flood hydrology, and having specific expertise with the Level 2 method.

  3. Radiometric dates from Alaska: A 1975 compilation

    USGS Publications Warehouse

    Turner, D.L.; Grybeck, Donald; Wilson, Frederic H.

    1975-01-01

    The following table of radiometric dates from Alaska includes published material through 1972 as well as some selected later data. The table includes 726 mineral and whole-rock dates determined by the K-Ar, Rb-Sr, fission-track U-Pb, and Pb-alpha techniques.The data are organized in alphabetical order of the 1:250,000 scale quadrangles in which the dated rocks are located. The latitude and longitude of each sample are given. In addition, each sample is located on a 1:250,000 quadrangle map by a grid system. The initial point of the grid is taken as the southwest corner of the quadrangle and the location of the sample is measured in inches east and inches north from that corner, e.g., "156E 126N" indicated 15.6 inches east and 12.6 inches north of the southwest corner of the quadrangle. Zeroes in the location columns for some dates indicate that accurate locations are not available.Rock type, dating method, mineral dated, radiometric age, sample identification number, and reference are also listed where possible. Short comments, mostly geographic locality names, are given for some dates. These comments have been taken from the original references.Sample identification numbers beginning with "AA" or "BB" have been assigned arbitrarily in cases where sample numbers were not assigned in the original references. Abbreviations are explained in the appendix at the end of table 1.

  4. Landsat-7 ETM+ radiometric calibration status

    NASA Astrophysics Data System (ADS)

    Barsi, Julia A.; Markham, Brian L.; Czapla-Myers, Jeffrey S.; Helder, Dennis L.; Hook, Simon J.; Schott, John R.; Haque, Md. Obaidul

    2016-09-01

    Now in its 17th year of operation, the Enhanced Thematic Mapper + (ETM+), on board the Landsat-7 satellite, continues to systematically acquire imagery of the Earth to add to the 40+ year archive of Landsat data. Characterization of the ETM+ on-orbit radiometric performance has been on-going since its launch in 1999. The radiometric calibration of the reflective bands is still monitored using on-board calibration devices, though the Pseudo-Invariant Calibration Sites (PICS) method has proven to be an effective tool as well. The calibration gains were updated in April 2013 based primarily on PICS results, which corrected for a change of as much as -0.2%/year degradation in the worst case bands. A new comparison with the SADE database of PICS results indicates no additional degradation in the updated calibration. PICS data are still being tracked though the recent trends are not well understood. The thermal band calibration was updated last in October 2013 based on a continued calibration effort by NASA/Jet Propulsion Lab and Rochester Institute of Technology. The update accounted for a 0.036 W/m2 sr μm or 0.26K at 300K bias error. The updated lifetime trend is now stable to within +/- 0.4K.

  5. Radiometric measurements of gap probability in conifer tree canopies

    NASA Technical Reports Server (NTRS)

    Albers, Bryan J.; Strahler, Alan H.; Li, Xiaowen; Liang, Shunlin; Clarke, Keith C.

    1990-01-01

    Measurements of gap probability were made for some moderate-sized, open-grown conifers of varying species. Results of the radiometric analysis show that the gap probability, which is taken as the mean of the binomial, fits well a negative exponential function of a path length. The conifer shadow, then, is an object of almost uniform darkness with some bright holes or gaps that are found near the shadow's edge and rapidly disappear toward the shadows center.

  6. Development of a rapid assimilable organic carbon method for water.

    PubMed

    Lechevallier, M W; Shaw, N E; Kaplan, L A; Bott, T L

    1993-05-01

    A rapid method for measurement of assimilable organic carbon (AOC) is proposed. The time needed to perform the assay is reduced by increasing the incubation temperature and increasing the inoculum density. The ATP luciferin-luciferase method quickly enumerates the test organisms without the need for plate count media or dilution bottles. There was no significant difference between AOC values determined with strain P17 for the ATP and plate count procedures. For strain NOX, the plate count procedure underestimated bacterial levels in some samples. Comparison of AOC values obtained by the Belleville laboratory (by the ATP technique) and the Stroud Water Research Center (by plate counts) showed that values were significantly correlated and not significantly different. The study concludes that the rapid AOC method can quickly determine the bacterial growth potential of water within 2 to 4 days.

  7. A Microwave Radiometric Method to Obtain the Average Path Profile of Atmospheric Temperature and Humidity Structure Parameters and Its Application to Optical Propagation System Assessment

    NASA Technical Reports Server (NTRS)

    Manning, Robert M.; Vyhnalek, Brian E.

    2015-01-01

    The values of the key atmospheric propagation parameters Ct2, Cq2, and Ctq are highly dependent upon the vertical height within the atmosphere thus making it necessary to specify profiles of these values along the atmospheric propagation path. The remote sensing method suggested and described in this work makes use of a rapidly integrating microwave profiling radiometer to capture profiles of temperature and humidity through the atmosphere. The integration times of currently available profiling radiometers are such that they are approaching the temporal intervals over which one can possibly make meaningful assessments of these key atmospheric parameters. Since these parameters are fundamental to all propagation conditions, they can be used to obtain Cn2 profiles for any frequency, including those for an optical propagation path. In this case the important performance parameters of the prevailing isoplanatic angle and Greenwood frequency can be obtained. The integration times are such that Kolmogorov turbulence theory and the Taylor frozen-flow hypothesis must be transcended. Appropriate modifications to these classical approaches are derived from first principles and an expression for the structure functions are obtained. The theory is then applied to an experimental scenario and shows very good results.

  8. JACIE Radiometric Assessment of QuickBird Multispectral Imagery

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Carver, David; Holekamp, Kara; Knowlton, Kelly; Ryan, Robert; Zanoni, Vicki; Thome, Kurtis; Aaron, David

    2004-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) directorate,through the Joint Agency for Commercial Imagery Evaluation (JACIE) framework, established a commercial imaging satellite radiometric calibration team consisting of two groups: 1) NASA SSC ESA, supported by South Dakota State University, and 2) the University of Arizona Remote Sensing Group. The two groups determined the absolute radiometric calibration coefficients of the Digital Globe 4-band, 2.4-m QuickBird multispectral product covering the visible through near-infrared spectral region. For a 2-year period beginning in 2002, both groups employed some variant of a reflectance-based vicarious calibration approach, which required ground-based measurements coincident with QuickBird image acquisitions and radiative transfer calculations. The groups chose several study sites throughout the United States that covered nearly the entire dynamic range of the QuickBird sensor. QuickBird at-sensor radiance values were compared with those estimated by the two independent groups to determine the QuickBird sensor's radiometric accuracy. Approximately 20 at-sensor radiance estimates were vicariously determined each year. The estimates were combined to provide a high-precision radiometric gain calibration coefficient. The results of this evaluation provide the user community with an independent assessment of the QuickBird sensor's absolute calibration and stability over the 2-year period. While the techniques and method described reflect those developed at the NASA SSC, the results of both JACIE team groups are

  9. A quantum chemical method for rapid optimization of protein structures.

    PubMed

    Wada, Mitsuhito; Sakurai, Minoru

    2005-01-30

    A quantum chemical method for rapid optimization of protein structures is proposed. In this method, a protein structure is treated as an assembly of amino acid units, and the geometry optimization of each unit is performed with taking the effect of its surrounding environment into account. The optimized geometry of a whole protein is obtained by repeated application of such a local optimization procedure over the entire part of the protein. Here, we implemented this method in the MOPAC program and performed geometry optimization for three different sizes of proteins. Consequently, these results demonstrate that the total energies of the proteins are much efficiently minimized compared with the use of conventional optimization methods, including the MOZYME algorithm (a representative linear-scaling method) with the BFGS routine. The proposed method is superior to the conventional methods in both CPU time and memory requirements.

  10. Detection of urinary tract infections by rapid methods.

    PubMed Central

    Pezzlo, M

    1988-01-01

    A review of rapid urine screens for detection of bacteriuria and pyuria demonstrates a number of available alternatives to the culture method. Selection of one or more of these systems for routine use is dependent upon the laboratory and the patient population being tested. The laboratory approach to the diagnosis of urinary tract infection should consider the clinical diagnosis of the patient whenever possible. Keeping in mind that quantitative urine cultures alone cannot be used to detect infection in some patient populations unless lower colony counts are considered, a rapid screen may be a more practical approach. It has become accepted that 10(5) CFU/ml can no longer be used as the standard for all patient groups, that pyuria often is important in making the diagnosis of a urinary tract infection, and that most of the rapid screens are more sensitive than the culture method at 10(5) CFU/ml. Presently, no one approach can be recommended for all laboratories and all patient groups. However, each diagnostic laboratory should select one approach which is best for its situation. It is not practical, efficient, or cost effective to define a protocol for each possible clinical condition; however, all should be considered when developing a protocol. This protocol should be compatible with the patient population and communicated to the physicians. Use of a rapid screen should be beneficial to the patient, the physician, and the laboratory. PMID:3058296

  11. The Radiometric Map of Australia

    NASA Astrophysics Data System (ADS)

    Minty, Brian; Franklin, Ross; Milligan, Peter; Richardson, Murray; Wilford, John

    2009-12-01

    Geoscience Australia and the Australian State and Territory Geological Surveys have systematically surveyed most of the Australian continent over the past 40 years using airborne gamma-ray spectrometry to map potassium, uranium and thorium elemental concentrations at the Earth's surface. However, the individual surveys that comprise the national gamma-ray spectrometric radioelement database are not all registered to the same datum. This limits the usefulness of the database as it is not possible to easily combine surveys into regional compilations or make accurate comparisons between radiometric signatures in different survey areas. To solve these problems, Geoscience Australia has undertaken an Australia-Wide Airborne Geophysical Survey (AWAGS), funded under the Australian Government's Onshore Energy Security Program, to serve as a radioelement baseline for all current and future airborne gamma-ray spectrometric surveys in Australia. The AWAGS survey has been back-calibrated to the International Atomic Energy Agency's (IAEA) radioelement datum. We have used the AWAGS data to level the national radioelement database by estimating survey correction factors that, once applied, minimise both the differences in radioelement estimates between surveys (where these surveys overlap) and the differences between the surveys and the AWAGS traverses. The database is thus effectively levelled to the IAEA datum. The levelled database has been used to produce the first `Radiometric Map of Australia' - levelled and merged composite potassium (% K), uranium (ppm eU) and thorium (ppm eTh) grids over Australia at 100m resolution. Interpreters can use the map to reliably compare the radiometric signatures observed over different parts of Australia. This enables the assessment of key mineralogical and geochemical properties of bedrock and regolith materials from different geological provinces and regions with contrasting landscape histories.

  12. Precision radiometric surface temperature (PRST) sensor

    NASA Astrophysics Data System (ADS)

    Daly, James T.; Roberts, Carson; Bodkin, Andrew; Sundberg, Robert; Beaven, Scott; Weinheimer, Jeffrey

    2013-05-01

    There is a need for a Precision Radiometric Surface Temperature (PRST) measurement capability that can achieve noncontact profiling of a sample's surface temperature when heated dynamically during laser processing, aerothermal heating or metal cutting/machining. Target surface temperature maps within and near the heated spot provide critical quantitative diagnostic data for laser-target coupling effectiveness and laser damage assessment. In the case of metal cutting, this type of measurement provides information on plastic deformation in the primary shear zone where the cutting tool is in contact with the workpiece. The challenge in these cases is to measure the temperature of a target while its surface's temperature and emissivity are changing rapidly and with incomplete knowledge of how the emissivity and surface texture (scattering) changes with temperature. Bodkin Design and Engineering, LLC (BDandE), with partners Spectral Sciences, Inc. (SSI) and Space Computer Corporation (SCC), has developed a PRST Sensor that is based on a hyperspectral MWIR imager spanning the wavelength range 2-5 μm and providing a hyperspectral datacube of 20-24 wavelengths at 60 Hz frame rate or faster. This imager is integrated with software and algorithms to extract surface temperature from radiometric measurements over the range from ambient to 2000K with a precision of 20K, even without a priori knowledge of the target's emissivity and even as the target emissivity may be changing with time and temperature. In this paper, we will present a description of the PRST system as well as laser heating test results which show the PRST system mapping target surface temperatures in the range 600-2600K on a variety of materials.

  13. Rapid separation method for actinides in emergency air filter samples.

    PubMed

    Maxwell, Sherrod L; Culligan, Brian K; Noyes, Gary W

    2010-12-01

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified (90)Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and (90)Sr in air filter results were reported in less than 4 h with excellent quality. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  15. Rapid qualitative method for detecting staphylococcal nuclease in foods.

    PubMed Central

    Koupal, A; Deibel, R H

    1978-01-01

    A rapid method for the detection of heat-stable staphylococcal nuclease in foods is described. The procedure consists of an acid precipitation, boiling, and centrifugation followed by enzyme detection in an agar plate containing deoxyribonucleic acid. To test the efficacy of the procedure, purified Staphylococcus aureus nuclease was added to various foods and recovery experiments were performed. Additionally, foods were inoculated and incubated with S. aureus, and the staphylococcal counts were compared with nuclease activity. The results indicate that the procedure possesses merit for a rapid method that can be incorporated into quality control programs. The procedure requires approximately 2.5 h, and it will detect nuclease levels as low as 10 ng/g of food. Images PMID:677882

  16. Turbo FISH: A Method for Rapid Single Molecule RNA FISH

    PubMed Central

    Shaffer, Sydney M.; Wu, Min-Tzu; Levesque, Marshall J.; Raj, Arjun

    2013-01-01

    Advances in RNA fluorescence in situ hybridization (RNA FISH) have allowed practitioners to detect individual RNA molecules in single cells via fluorescence microscopy, enabling highly accurate and sensitive quantification of gene expression. However, current methods typically employ hybridization times on the order of 2–16 hours, limiting its potential in applications like rapid diagnostics. We present here a set of conditions for RNA FISH (dubbed Turbo RNA FISH) that allow us to make accurate measurements with no more than 5 minutes of hybridization time and 3 minutes of washing, and show that hybridization times can go as low as 30 seconds while still producing quantifiable images. We further show that rapid hybridization is compatible with our recently developed iceFISH and SNP FISH variants of RNA FISH that enable chromosome and single base discrimination, respectively. Our method is simple and cost effective, and has the potential to dramatically increase the throughput and realm of applicability of RNA FISH. PMID:24066168

  17. A new ultrasound based method for rapid microorganism detection

    NASA Astrophysics Data System (ADS)

    Shukla, Shiva Kant; Segura, Luis Elvira; Sánchez, Carlos José Sierra; López, Pablo Resa

    2012-05-01

    A new method for rapid detection of catalase positive microorganisms by using an ultrasonic measuring method is proposed in this work. The developed technique is based on the detection of oxygen bubbles produced by the hydrolysis of hydrogen peroxide induced by the enzyme catalase which is present in many microorganisms. The bubbles are trapped in a media based on agar gel which was especially developed for microbiological evaluation. It is found that microorganism concentrations of the order of 105 c.f.u./ml can be detected by using this method. The results obtained show up that the proposed method is competitive with other modern commercial methods like luminescence by ATP system. The method can also be used for characterization of enzyme activity.

  18. Preparing Silica Aerogel Monoliths via a Rapid Supercritical Extraction Method

    PubMed Central

    Gorka, Caroline A.

    2014-01-01

    A procedure for the fabrication of monolithic silica aerogels in eight hours or less via a rapid supercritical extraction process is described. The procedure requires 15-20 min of preparation time, during which a liquid precursor mixture is prepared and poured into wells of a metal mold that is placed between the platens of a hydraulic hot press, followed by several hours of processing within the hot press. The precursor solution consists of a 1.0:12.0:3.6:3.5 x 10-3 molar ratio of tetramethylorthosilicate (TMOS):methanol:water:ammonia. In each well of the mold, a porous silica sol-gel matrix forms. As the temperature of the mold and its contents is increased, the pressure within the mold rises. After the temperature/pressure conditions surpass the supercritical point for the solvent within the pores of the matrix (in this case, a methanol/water mixture), the supercritical fluid is released, and monolithic aerogel remains within the wells of the mold. With the mold used in this procedure, cylindrical monoliths of 2.2 cm diameter and 1.9 cm height are produced. Aerogels formed by this rapid method have comparable properties (low bulk and skeletal density, high surface area, mesoporous morphology) to those prepared by other methods that involve either additional reaction steps or solvent extractions (lengthier processes that generate more chemical waste).The rapid supercritical extraction method can also be applied to the fabrication of aerogels based on other precursor recipes. PMID:24637334

  19. Preparing silica aerogel monoliths via a rapid supercritical extraction method.

    PubMed

    Carroll, Mary K; Anderson, Ann M; Gorka, Caroline A

    2014-02-28

    A procedure for the fabrication of monolithic silica aerogels in eight hours or less via a rapid supercritical extraction process is described. The procedure requires 15-20 min of preparation time, during which a liquid precursor mixture is prepared and poured into wells of a metal mold that is placed between the platens of a hydraulic hot press, followed by several hours of processing within the hot press. The precursor solution consists of a 1.0:12.0:3.6:3.5 x 10(-3) molar ratio of tetramethylorthosilicate (TMOS):methanol:water:ammonia. In each well of the mold, a porous silica sol-gel matrix forms. As the temperature of the mold and its contents is increased, the pressure within the mold rises. After the temperature/pressure conditions surpass the supercritical point for the solvent within the pores of the matrix (in this case, a methanol/water mixture), the supercritical fluid is released, and monolithic aerogel remains within the wells of the mold. With the mold used in this procedure, cylindrical monoliths of 2.2 cm diameter and 1.9 cm height are produced. Aerogels formed by this rapid method have comparable properties (low bulk and skeletal density, high surface area, mesoporous morphology) to those prepared by other methods that involve either additional reaction steps or solvent extractions (lengthier processes that generate more chemical waste).The rapid supercritical extraction method can also be applied to the fabrication of aerogels based on other precursor recipes.

  20. Rapid quantification method for Legionella pneumophila in surface water.

    PubMed

    Wunderlich, Anika; Torggler, Carmen; Elsässer, Dennis; Lück, Christian; Niessner, Reinhard; Seidel, Michael

    2016-03-01

    World-wide legionellosis outbreaks caused by evaporative cooling systems have shown that there is a need for rapid screening methods for Legionella pneumophila in water. Antibody-based methods for the quantification of L. pneumophila are rapid, non-laborious, and relatively cheap but not sensitive enough for establishment as a screening method for surface and drinking water. Therefore, preconcentration methods have to be applied in advance to reach the needed sensitivity. In a basic test, monolithic adsorption filtration (MAF) was used as primary preconcentration method that adsorbs L. pneumophila with high efficiency. Ten-liter water samples were concentrated in 10 min and further reduced to 1 mL by centrifugal ultrafiltration (CeUF). The quantification of L. pneumophila strains belonging to the monoclonal subtype Bellingham was performed via flow-based chemiluminescence sandwich microarray immunoassays (CL-SMIA) in 36 min. The whole analysis process takes 90 min. A polyclonal antibody (pAb) against L. pneumophila serogroup 1-12 and a monoclonal antibody (mAb) against L. pneumophila SG 1 strain Bellingham were immobilized on a microarray chip. Without preconcentration, the detection limit was 4.0 × 10(3) and 2.8 × 10(3) CFU/mL determined by pAb and mAb 10/6, respectively. For samples processed by MAF-CeUF prior to SMIA detection, the limit of detection (LOD) could be decreased to 8.7 CFU/mL and 0.39 CFU/mL, respectively. A recovery of 99.8 ± 15.9% was achieved for concentrations between 1-1000 CFU/mL. The established combined analytical method is sensitive for rapid screening of surface and drinking water to allow fast hygiene control of L. pneumophila.

  1. Evaluation of the enhanced rapid identification method for Gardnerella vaginalis.

    PubMed Central

    Lien, E A; Hillier, S L

    1989-01-01

    The enhanced rapid identification method (RIM; Austin Biological Laboratories), a micromethod for the identification of Gardnerella vaginalis, is based on starch and raffinose fermentation and hippurate hydrolysis. We tested 105 clinical isolates of G. vaginalis with both the RIM and standard biochemical tests. The RIM agreed with the standard biochemical methods for 96 (91.4%) of the strains; nine isolates which were hippurate hydrolysis positive by standard biochemical tests were hippurate hydrolysis negative in the RIM. RIM may serve as a useful adjunct to Gram stain and colony morphology for the identification of G. vaginalis. PMID:2785533

  2. Method for rapidly producing microporous and mesoporous materials

    DOEpatents

    Coronado, P.R.; Poco, J.F.; Hrubesh, L.W.; Hopper, R.W.

    1997-11-11

    An improved, rapid process is provided for making microporous and mesoporous materials, including aerogels and pre-ceramics. A gel or gel precursor is confined in a sealed vessel to prevent structural expansion of the gel during the heating process. This confinement allows the gelation and drying processes to be greatly accelerated, and significantly reduces the time required to produce a dried aerogel compared to conventional methods. Drying may be performed either by subcritical drying with a pressurized fluid to expel the liquid from the gel pores or by supercritical drying. The rates of heating and decompression are significantly higher than for conventional methods. 3 figs.

  3. Method for rapidly producing microporous and mesoporous materials

    DOEpatents

    Coronado, Paul R.; Poco, John F.; Hrubesh, Lawrence W.; Hopper, Robert W.

    1997-01-01

    An improved, rapid process is provided for making microporous and mesoporous materials, including aerogels and pre-ceramics. A gel or gel precursor is confined in a sealed vessel to prevent structural expansion of the gel during the heating process. This confinement allows the gelation and drying processes to be greatly accelerated, and significantly reduces the time required to produce a dried aerogel compared to conventional methods. Drying may be performed either by subcritical drying with a pressurized fluid to expel the liquid from the gel pores or by supercritical drying. The rates of heating and decompression are significantly higher than for conventional methods.

  4. Rapid methods for jugular bleeding of dogs requiring one technician.

    PubMed

    Frisk, C S; Richardson, M R

    1979-06-01

    Two methods were used to collect blood from the jugular vein of dogs. In both techniques, only one technician was required. A rope with a slip knot was placed around the base of the neck to assist in restraint and act as a tourniquet for the vein. The technician used one hand to restrain the dog by the muzzle and position the head. The other hand was used for collecting the sample. One of the methods could be accomplished with the dog in its cage. The bleeding techniques were rapid, requiring approximately 1 minute per dog.

  5. Rapid method for fabricating polymeric biconvex parabolic lenslets.

    PubMed

    Sun, Rongrong; Li, Yang; Li, Lei

    2014-09-15

    Microlenslets as well as microlens arrays have shown tremendous attractions and successes in miniature optical systems in recent decades. However, the fabrication methods for microlenslets and microlenslet arrays are limited. In this Letter, a rapid and low-cost method for fabricating polymeric biconvex lenslets is presented. This newly developed process is simply based on wetting behavior at interface and is able to produce high-quality biconvex lenslets with controllable size and shape. This technology will greatly simplify the production process and reduce the manufacturing costs for micro-optics.

  6. A Non-Radiative Transfer Approach to Radiometric Vicarious Calibration

    NASA Technical Reports Server (NTRS)

    Ryan, Robert; Holekamp, Kara; Pagnutti, Mary; Stanley, Thomas

    2007-01-01

    TOA (top-of-atmosphere) radiance from high-spatial-resolution satellite imagery systems is important for a wide variety of research and applications. Many research initiatives require data with absolute radiometric accuracy better than a few percent. The conversion of satellite digital numbers to radiance depends on accurate radiometric calibration. A common method for determining and validating radiometric calibrations is to rely upon vicarious calibration approaches. Historically, vicarious calibration methods use radiative transfer codes with ground-based atmosphere and surface reflectance or radiance inputs for estimating TOA radiance values. These TOA radiance values are compared against the satellite digital numbers to determine the radiometric calibration. However, the radiative transfer codes used depend on many assumptions about the aerosol properties and the atmospheric point spread function. A measurement-based atmospheric radiance estimation approach for high-spatial-resolution, multispectral, visible/near-infrared sensors is presented that eliminates the use of radiative transfer codes and many of the underlying assumptions. A comparison between the radiative transfer and non-radiative transfer approaches is made.

  7. Rapid and alternative screening methods for microbiological analysis.

    PubMed

    van der Zee, H; Huis in't Veld, J H

    1997-01-01

    Automated analytical instruments for enumerating indicator organisms and diagnostic test kits for pathogens can be used in food microbiology to screen samples and to replace conventional cultural and confirmation steps. Such methods are now available for rapid detection or estimation of groups of (indicator) organisms, pathogenic micro-organisms, bacterial toxins and mycotoxins, and molds. These alternative methods can be classified by the principles on which they are based: modified conventional methods, instrumental measurement of bacterial metabolism, bioluminescence, immunological techniques, DNA techniques, and combinations of these techniques. To meet user expectations, test kits must be accurate, sensitive, specific, rapid (24 h or less), easy to use, and labor-saving. They must also offer the possibility of computerization, a low detection limit, and low investment and running costs. The paper compares the ability of alternative methods to meet these criteria. Variations were found, depending on the techniques used and the target organism of the analysis. Economic reasons can determine whether alternative methods can be used routinely. Adoption of these screening systems also can be hampered by lack of internationally coordinated and accepted validation protocols.

  8. [Methods of rapid diagnosis in clinical microbiology: Clinical needs].

    PubMed

    Vila, Jordi; Gómez, María Dolores; Salavert, Miguel; Bosch, Jordi

    2017-01-01

    The diagnostic methods of infectious diseases should be fast, accurate, simple and affordable. The speed of diagnosis can play a crucial role in healing the patient, allowing the administration of appropriate antibiotic treatment. One aspect that increasingly determines the need for rapid diagnostic techniques is the increased rates of serious infections caused by multidrug resistant bacteria, which cause a high probability of error in the empirical treatment. Some of the conventional methods such as Gram staining or antigen detection can generate results in less than 1 hour but lack sensitivity. Today we are witnessing a major change in clinical microbiology laboratories with the technological advances such as molecular diagnostics, digital microbiology and mass spectrometry. There are several studies showing that these changes in the microbiological diagnosis reduce the generation time of the test results, which has an obvious clinical impact. However, if we look into the future, other new technologies which will cover the needs required for a rapid microbiological diagnosis are on the horizon. This review provides an in depth analysis of the clinical impact that the implementation of rapid diagnostic techniques will have on unmet clinical needs.

  9. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues

    NASA Astrophysics Data System (ADS)

    Ji, Wei; Yao, Weirong

    2015-06-01

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm-1, 1344 cm-1, 1596 cm-1, which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm-1 was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R2 = 0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples.

  10. SIMS: A Hybrid Method for Rapid Conformational Analysis

    PubMed Central

    Gipson, Bryant; Moll, Mark; Kavraki, Lydia E.

    2013-01-01

    Proteins are at the root of many biological functions, often performing complex tasks as the result of large changes in their structure. Describing the exact details of these conformational changes, however, remains a central challenge for computational biology due the enormous computational requirements of the problem. This has engendered the development of a rich variety of useful methods designed to answer specific questions at different levels of spatial, temporal, and energetic resolution. These methods fall largely into two classes: physically accurate, but computationally demanding methods and fast, approximate methods. We introduce here a new hybrid modeling tool, the Structured Intuitive Move Selector (sims), designed to bridge the divide between these two classes, while allowing the benefits of both to be seamlessly integrated into a single framework. This is achieved by applying a modern motion planning algorithm, borrowed from the field of robotics, in tandem with a well-established protein modeling library. sims can combine precise energy calculations with approximate or specialized conformational sampling routines to produce rapid, yet accurate, analysis of the large-scale conformational variability of protein systems. Several key advancements are shown, including the abstract use of generically defined moves (conformational sampling methods) and an expansive probabilistic conformational exploration. We present three example problems that sims is applied to and demonstrate a rapid solution for each. These include the automatic determination of “active” residues for the hinge-based system Cyanovirin-N, exploring conformational changes involving long-range coordinated motion between non-sequential residues in Ribose-Binding Protein, and the rapid discovery of a transient conformational state of Maltose-Binding Protein, previously only determined by Molecular Dynamics. For all cases we provide energetic validations using well-established energy

  11. A novel method for rapid in vitro radiobioassay

    NASA Astrophysics Data System (ADS)

    Crawford, Evan Bogert

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are the detonation of a radiation dispersal device (RDD, "dirty bomb") or the accidental release of an isotope from an industrial source such as a radioisotopic thermal generator (RTG). In the event of the release and dispersion of radioactive materials into the environment in a large city, the entire population of the city -- including all commuting workers and tourists -- would have to be rapidly tested, both to satisfy the psychological needs of the citizens who were exposed to the mental trauma of a possible radiation dose, and to satisfy the immediate medical needs of those who received the highest doses and greatest levels of internal contamination -- those who would best benefit from rapid, intensive medical care. In this research a prototype rapid screening method to screen urine samples for the presence of up to five isotopes, both individually and in a mixture, has been developed. The isotopes used to develop this method are Co-60, Sr-90, Cs-137, Pu-238, and Am-241. This method avoids time-intensive chemical separations via the preparation and counting of a single sample on multiple detectors, and analyzing the spectra for isotope-specific markers. A rapid liquid-liquid separation using an organic extractive scintillator can be used to help quantify the activity of the alpha-emitting isotopes. The method provides quantifiable results in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their respective intervention levels in approximately 30

  12. A novel method for rapidly diagnosing the causes of diarrhoea

    PubMed Central

    Probert, C S J; Jones, P R H; Ratcliffe, N M

    2004-01-01

    Background: The microbiological diagnosis of infectious diarrhoea may take several days using conventional techniques. In order to determine whether flatus can be used to make a rapid diagnosis, the volatile organic compounds associated with diarrhoea were analysed. Methods: Stool samples were collected from 35 patients with infectious diarrhoea and from six healthy controls. Gaseous compounds were extracted from a headspace using solid phase microextraction and analysed using gas chromatography and mass spectroscopy. Results: Characteristic patterns of volatile gases were found for the main causes of infectious diarrhoea in hospitals. Furan species without indoles indicated Clostridium difficile, ethyl dodecanoate indicated rotavirus, ammonia without ethyl dodecanoate suggested other enteric viruses, and the absence of hydrocarbons and terpenes indicated Campylobacter infection. Conclusion: These results could be the basis of rapid near patient diagnosis of infectious diarrhoea. PMID:14684577

  13. New Rapid Method of DNA Isolation from Milk Somatic Cells.

    PubMed

    Pokorska, Joanna; Kułaj, Dominika; Dusza, Magdalena; Żychlińska-Buczek, Justyna; Makulska, Joanna

    2016-01-01

    Isolation of genomic DNA is one of the basic steps in many different molecular analyses. There are a few reports on methods of DNA isolation from milk, but many of them are time consuming and expensive, and require relatively large volumes of raw milk. In this study a rapid, sensitive, and efficient method of DNA extraction from milk somatic cells of various mammals (cattle, sheep, goats, horses) is presented. It was found that milk is a good source of genomic DNA, and to obtain a sufficient amount and quality of DNA, suitable for molecular analysis such as PCR, 10 mL of raw milk is sufficient. Thanks to this method, stress in animals can be reduced during collection of researched material. Therefore, this method could be widely used in molecular analyses.

  14. Rapid Methods for High-Throughput Detection of Sulfoxides▿

    PubMed Central

    Shainsky, Janna; Derry, Netta-Lee; Leichtmann-Bardoogo, Yael; Wood, Thomas K.; Fishman, Ayelet

    2009-01-01

    Enantiopure sulfoxides are prevalent in drugs and are useful chiral auxiliaries in organic synthesis. The biocatalytic enantioselective oxidation of prochiral sulfides is a direct and economical approach for the synthesis of optically pure sulfoxides. The selection of suitable biocatalysts requires rapid and reliable high-throughput screening methods. Here we present four different methods for detecting sulfoxides produced via whole-cell biocatalysis, three of which were exploited for high-throughput screening. Fluorescence detection based on the acid activation of omeprazole was utilized for high-throughput screening of mutant libraries of toluene monooxygenases, but no active variants have been discovered yet. The second method is based on the reduction of sulfoxides to sulfides, with the coupled release and measurement of iodine. The availability of solvent-resistant microtiter plates enabled us to modify the method to a high-throughput format. The third method, selective inhibition of horse liver alcohol dehydrogenase, was used to rapidly screen highly active and/or enantioselective variants at position V106 of toluene ortho-monooxygenase in a saturation mutagenesis library, using methyl-p-tolyl sulfide as the substrate. A success rate of 89% (i.e., 11% false positives) was obtained, and two new mutants were selected. The fourth method is based on the colorimetric detection of adrenochrome, a back-titration procedure which measures the concentration of the periodate-sensitive sulfide. Due to low sensitivity during whole-cell screening, this method was found to be useful only for determining the presence or absence of sulfoxide in the reaction. The methods described in the present work are simple and inexpensive and do not require special equipment. PMID:19465532

  15. A rapid DNA extraction method suitable for human papillomavirus detection.

    PubMed

    Brestovac, Brian; Wong, Michelle E; Costantino, Paul S; Groth, David

    2014-04-01

    Infection with oncogenic human papillomavirus (HPV) genotypes is necessary for the development of cervical cancer. Testing for HPV DNA from liquid based cervical samples can be used as an adjunct to traditional cytological screening. In addition there are ongoing viral load, genotyping, and prevalence studies. Therefore, a sensitive DNA extraction method is needed to maximize the efficiency of HPV DNA detection. The XytXtract Tissue kit is a DNA extraction kit that is rapid and so could be useful for HPV testing, particularly in screening protocols. This study was undertaken to determine the suitability of this method for HPV detection. DNA extraction from HeLa and Caski cell lines containing HPV 18 and 16 respectively together with DNA from five liquid based cervical samples were used in a HPV PCR assay. DNA was also extracted using the QIAamp DNA mini kit (Qiagen, Hilden, Germany) as a comparison. DNA extracts were serially diluted and assayed. HPV DNA was successfully detected in cell lines and cervical samples using the XytXtract Tissue kit. In addition, the XytXtract method was found to be more sensitive than the QIAmp method as determined by a dilution series of the extracted DNA. While the XytXtract method is a closed, the QIAamp method uses a spin column with possible loss of DNA through DNA binding competition of the matrix, which could impact on the final extraction efficiency. The XytXtract is a cheap, rapid and efficient method for extracting HPV DNA from both cell lines and liquid based cervical samples.

  16. A Rapid Usability Evaluation (RUE) Method for Health Information Technology.

    PubMed

    Russ, Alissa L; Baker, Darrell A; Fahner, W Jeffrey; Milligan, Bryce S; Cox, Leeann; Hagg, Heather K; Saleem, Jason J

    2010-11-13

    Usability testing can help generate design ideas to enhance the quality and safety of health information technology. Despite these potential benefits, few healthcare organizations conduct systematic usability testing prior to software implementation. We used a Rapid Usability Evaluation (RUE) method to apply usability testing to software development at a major VA Medical Center. We describe the development of the RUE method, provide two examples of how it was successfully applied, and discuss key insights gained from this work. Clinical informaticists with limited usability training were able to apply RUE to improve software evaluation and elected to continue to use this technique. RUE methods are relatively simple, do not require advanced training or usability software, and should be easy to adopt. Other healthcare organizations may be able to implement RUE to improve software effectiveness, efficiency, and safety.

  17. A Rapid Method for the Diagnosis of Equine Virus Abortion

    PubMed Central

    Correa, W. M.

    1970-01-01

    Smears and imprints were made from the liver of 27 equine fetuses, believed to have aborted as a result of Equine Virus Abortion (EVA) infection. Several different fixatives and staining techniques were employed for the demonstration of typical intra-nuclear inclusion bodies in these preparations, and the following conclusions were reached. Methanol proved to be the best fixative and Pappenheim's panoptic method was the best staining technique, giving good contrast and definition of the inclusion bodies. Cytological methods provided a simple and rapid means of diagnosis, but histological sections provided evidence of lesions which was most useful when inclusion bodies were very difficult to find. However, cytological methods proved better than histological sections for the demonstration of EVA intranuclear inclusion bodies. ImagesFig. 1. PMID:4192198

  18. Rapid method for identification of gram-negative, nonfermentative bacilli.

    PubMed Central

    Otto, L A; Pickett, M J

    1976-01-01

    A rapid system (OA), based on oxidative attack of substrates, was developed for identification of gram-negative, nonfermentative bacillia (NFB). One hundred and twelve strains of NFB from 25 species (representing the genera Pseudomonas, Alcaligenes, Acinetobacter, Bordetella, Flavobacterium, Moraxella, and Xanthomonas) were assayed by OA, buffered single substrate, and oxidative/fermentative methods. The 38 substrates consisted of salts of organic acids, nitrogen-containing compounds, alcohols, and carbohydrates. Ninety-four percent of the test strains were identified by the OA method in 24 h, and 99% were identifiable in 48 h. Reproducibility was 99%. Correlation with buffered single substrate was 98% (all substrates) and 90% with the oxidative/fermentative method (carbohydrates only). Biochemical profiles of all strains are presented, as well as tables showing the most useful tests for identification. PMID:780371

  19. Method for producing rapid pH changes

    DOEpatents

    Clark, John H.; Campillo, Anthony J.; Shapiro, Stanley L.; Winn, Kenneth R.

    1981-01-01

    A method of initiating a rapid pH change in a solution by irradiating the solution with an intense flux of electromagnetic radiation of a frequency which produces a substantial pK change to a compound in solution. To optimize the resulting pH change, the compound being irradiated in solution should have an excited state lifetime substantially longer than the time required to establish an excited state acid-base equilibrium in the solution. Desired pH changes can be accomplished in nanoseconds or less by means of picosecond pulses of laser radiation.

  20. Method for producing rapid pH changes

    DOEpatents

    Clark, J.H.; Campillo, A.J.; Shapiro, S.L.; Winn, K.R.

    A method of initiating a rapid pH change in a solution comprises irradiating the solution with an intense flux of electromagnetic radiation of a frequency which produces a substantial pK change to a compound in solution. To optimize the resulting pH change, the compound being irradiated in solution should have an excited state lifetime substantially longer than the time required to establish an excited state acid-base equilibrium in the solution. Desired pH changes can be accomplished in nanoseconds or less by means of picosecond pulses of laser radiation.

  1. Method for rapidly determining a pulp kappa number using spectrophotometry

    SciTech Connect

    Chai, Xin-Sheng; Zhu, Jun Yong

    2002-01-01

    A system and method for rapidly determining the pulp kappa number through direct measurement of the potassium permanganate concentration in a pulp-permanganate solution using spectrophotometry. Specifically, the present invention uses strong acidification to carry out the pulp-permanganate oxidation reaction in the pulp-permanganate solution to prevent the precipitation of manganese dioxide (MnO.sub.2). Consequently, spectral interference from the precipitated MnO.sub.2 is eliminated and the oxidation reaction becomes dominant. The spectral intensity of the oxidation reaction is then analyzed to determine the pulp kappa number.

  2. Small satellite radiometric measurement system

    SciTech Connect

    Weber, P.G.

    1992-01-01

    A critical need for the US Global Change Research Program is to provide continuous, well-calibrated radiometric data for the earth's radiation budget. This paper describes a new, compact, relatively light-weight, adaptable radiometer which will provide both spectrally integrated measurements and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted aircraft (RPAs). An example of the implementation of this radiometer on a small satellite is given. Significant benefits derive from simultaneous measurements of specific narrow (in wavelength) spectral features; such data may be obtained by combining LARI with a compact spectrometer on the same platform. Well-chosen satellite orbits allow one to use data from other satellites (e.g. DMSP) to enhance the data product, or to provide superior coverage of specific locations. 23 refs.

  3. Small satellite radiometric measurement system

    SciTech Connect

    Weber, P.G.

    1992-01-01

    A critical need for the US Global Change Research Program is to provide continuous, well-calibrated radiometric data for the earth`s radiation budget. This paper describes a new, compact, relatively light-weight, adaptable radiometer which will provide both spectrally integrated measurements and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted aircraft (RPAs). An example of the implementation of this radiometer on a small satellite is given. Significant benefits derive from simultaneous measurements of specific narrow (in wavelength) spectral features; such data may be obtained by combining LARI with a compact spectrometer on the same platform. Well-chosen satellite orbits allow one to use data from other satellites (e.g. DMSP) to enhance the data product, or to provide superior coverage of specific locations. 23 refs.

  4. Detection of anti-tuberculosis activity in some folklore plants by radiometric BACTEC assay.

    PubMed

    Gupta, V K; Shukla, C; Bisht, G R S; Saikia, D; Kumar, S; Thakur, R L

    2011-01-01

    The anti-tubercular drugs are less effective because of the emergence of multi-drug resistant (MDR) and extensively drug resistant (XDR) strains of M. tuberculosis, so plants being an alternative source of anti-microbial compounds. The aim of this study was to investigate anti-tuberculosis potential of the plants using Mycobacterium smegmatis as a rapid screening model for detection of anti-mycobacterial activity and further to evaluate the active plants for anti-tuberculosis activity against M. tuberculosis using radiometric BACTEC assay. The 15 plants were screened for anti-mycobacterial activity against M. smegmatis by the disk diffusion assay. The ethanolic extracts of Mallotus philippensis, Vitex negundo, Colebrookea oppositifolia, Rumex hastatus, Mimosa pudica, Kalanchoe integra and Flacourtia ramontchii were active against M. smegmatis in primary screening. The anti-tuberculosis potential was identified in the leaves extracts of Mallotus philippensis by radiometric BACTEC assay. The ethanolic extract of M. philippensis showed anti-tuberculosis activity against virulent and avirulent strains of M. tuberculosis H(37) Rv and M. tuberculosis H(37) Ra with minimum inhibitory concentration 0·25 and 0·125 mg ml(-1), respectively. The inhibition in growth index values of M. tuberculosis was observed in the presence of ethyl acetate fraction at a minimum concentration of 0·05 mg ml(-1). We found that BACTEC radiometric assay is a valuable method for detection of anti-tuberculosis activity of the plant extracts. The results indicate that ethanolic extract and ethyl acetate fraction of M. philippensis exhibited significant anti-mycobacterial activity against M. tuberculosis. These findings provide scientific evidence to support the traditional medicinal uses of M. philippensis and indicate a promising potential of this plant for the development of anti-tuberculosis agent. © 2010 The Authors. Letters in Applied Microbiology © 2010 The Society for Applied

  5. Rapid broth macrodilution method for determination of MICs for Mycobacterium avium isolates.

    PubMed Central

    Siddiqi, S H; Heifets, L B; Cynamon, M H; Hooper, N M; Laszlo, A; Libonati, J P; Lindholm-Levy, P J; Pearson, N

    1993-01-01

    A multicenter study was done to investigate the accuracy and reproducibility of a method for determining the MICs of antimicrobial agents against the Mycobacterium avium complex in 7H12 broth with the BACTEC system. In phase I, with eight drugs and 10 strains, intralaboratory reproducibility was 95.7 to 100%, allowing a 1-dilution difference upon repeat testing. The results of phase II testing with 41 additional strains were consistent with those obtained in phase I, with good interlaboratory reproducibility. The radiometric method was validated by sampling and plating of the same broth cultures and determining, by the number of CFU per milliliter, the lowest drug concentration that inhibited more than 99% of the initial bacterial population. Three test concentrations of each drug and the tentative interpretation of results are proposed. Radiometric MIC determination has the potential to become the method of choice for clinical microbiology laboratories and evaluation of new agents for the treatment of M. avium infections, both pulmonary and disseminated. Images PMID:8408551

  6. A rapid method for the presurgical cleansing of hands.

    PubMed

    Decker, L A; Gross, A; Miller, F C; Read, J A; Cutright, D E; Devine, J

    1978-01-01

    A new rapid method of presurgical cleansing of the hands has been evaluated in a clinical setting. The effectiveness of a 90 second jet wash has been compared with a standard 10-minute presurgical scrub. Bacteriologic cultures were obtained from the fingertips of interns, residents, and staff of the Department of Obstetrics and Gynecology of the Walter Reed Army Medical Center before and after 90-second jet washings and 10-minute conventional scrubs. The results showed that the 90-second jet wash was more effective in degerming the hands than the 10-minute standard brush scrub. Other advantages of the new method, such as the amount of time saved, the standardization of cleansing, and reduced skin irritation are discussed.

  7. A simple, rapid method for HPLC analysis of lycopene isomers.

    PubMed

    Ishida, B K; Ma, J; Chan, B

    2001-01-01

    A rapid method for the extraction, separation and quantification of the geometric isomers of lycopene and beta-carotene from tomato fruit is described. Carotenoids in tomato were separated and eluted using a reversed-phase HPLC with a C30 column and a mobile phase consisting of methyl-t-butyl ether, methanol and ethyl acetate. The system provided sharp resolution of cis- and trans-isomers of lycopene within approximately 23 min in contrast to the longer and more complex gradient procedures required by previously described methods. Experiments indicate that the stability of extracts of fresh tomato may be improved if stored at -20 degrees C, and that the presence of the antioxidant BHA has no apparent effect on stability.

  8. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared to NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.

  9. Rapid method for proline determination in grape juice and wine.

    PubMed

    Long, Danfeng; Wilkinson, Kerry L; Poole, Kate; Taylor, Dennis K; Warren, Tristan; Astorga, Alejandra M; Jiranek, Vladimir

    2012-05-02

    Proline is typically the most abundant amino acid present in grape juice and wine. The amount present is influenced by viticultural and winemaking factors and can be of diagnostic importance. A method for rapid routine quantitation of proline would therefore be of benefit for wine researchers and the industry in general. Colorimetric determination utilizing isatin as a derivatizing agent has previously been applied to plant extracts, biological fluids, and protein hydrolysates. In the current study, this method has been successfully adapted to grape juice and wine and proved to be sensitive to milligram per liter amounts of proline. At sugar concentrations above 60 g/L, interference from the isatin-proline reaction was observed, such that proline concentrations were considerably underestimated in grape juice and dessert wine. However, the method was robust for the analysis of fermentation samples and table wines. Results were within ±10% agreement with data generated from typical HPLC-based analyses. The isatin method is therefore considered suitable for the routine analysis required to support research into the utilization or release of proline by yeast during fermentation.

  10. High speed radiometric measurements of IED detonation fireballs

    NASA Astrophysics Data System (ADS)

    Spidell, Matthew T.; Gordon, J. Motos; Pitz, Jeremey; Gross, Kevin C.; Perram, Glen P.

    2010-04-01

    Continuum emission is predominant in fireball spectral phenomena and in some demonstrated cases, fine detail in the temporal evolution of infrared spectral emissions can be used to estimate size and chemical composition of the device. Recent work indicates that a few narrow radiometric bands may reveal forensic information needed for the explosive discrimination and classification problem, representing an essential step in moving from "laboratory" measurements to a rugged, fieldable system. To explore phenomena not observable in previous experiments, a high speed (10μs resolution) radiometer with four channels spanning the infrared spectrum observed the detonation of nine home made explosive (HME) devices in the < 100lb class. Radiometric measurements indicate that the detonation fireball is well approximated as a single temperature blackbody at early time (0 < t <~ 3ms). The effective radius obtained from absolute intensity indicates fireball growth at supersonic velocity during this time. Peak fireball temperatures during this initial detonation range between 3000.3500K. The initial temperature decay with time (t <~ 10ms) can be described by a simple phenomenological model based on radiative cooling. After this rapid decay, temperature exhibits a small, steady increase with time (10 <~ t <~ 50ms) and peaking somewhere between 1000.1500K-likely the result of post-detonation combustion-before subsequent cooling back to ambient conditions . Radius derived from radiometric measurements can be described well (R2 > 0.98) using blast model functional forms, suggesting that energy release could be estimated from single-pixel radiometric detectors. Comparison of radiometer-derived fireball size with FLIR infrared imagery indicate the Planckian intensity size estimates are about a factor of two smaller than the physical extent of the fireball.

  11. Statistical Methods for Rapid Aerothermal Analysis and Design Technology: Validation

    NASA Technical Reports Server (NTRS)

    DePriest, Douglas; Morgan, Carolyn

    2003-01-01

    The cost and safety goals for NASA s next generation of reusable launch vehicle (RLV) will require that rapid high-fidelity aerothermodynamic design tools be used early in the design cycle. To meet these requirements, it is desirable to identify adequate statistical models that quantify and improve the accuracy, extend the applicability, and enable combined analyses using existing prediction tools. The initial research work focused on establishing suitable candidate models for these purposes. The second phase is focused on assessing the performance of these models to accurately predict the heat rate for a given candidate data set. This validation work compared models and methods that may be useful in predicting the heat rate.

  12. Method for rapid, high sensitivity tritiated water extraction

    SciTech Connect

    Failor, R.; Belovodsky, L.; Gaevoy, V.; Golubev, A.

    1997-04-20

    We have developed a thermal vacuum desorption process to rapidly extract water from environmental samples for tritium analysis. Thermal vacuum desorption allows for extraction of the moisture from the sample within a few hours in a form and quantity suitable for liquid scintillation counting and allows detection of tritium at the levels of <2 Bq/L of milk, <0.5 Bq/gm of vegetation, and < 0.5 Bq/gin of soil. We developed a prototype unit that can process batches of twenty or more samples within 24 hours. Early data shows that a high percentage of water is extracted reproducibly without enrichment or depletion of the tritium content. The quench coefficient of the extracted water is low allowing for accurate, direct liquid scintillation counting. Excellent comparison has been observed with results using freeze-dry lypholization as the water extraction method.

  13. A simple method for rapidly processing HEU from weapons returns

    SciTech Connect

    McLean, W. II; Miller, P.E.

    1994-01-01

    A method based on the use of a high temperature fluidized bed for rapidly oxidizing, homogenizing and down-blending Highly Enriched Uranium (HEU) from dismantled nuclear weapons is presented. This technology directly addresses many of the most important issues that inhibit progress in international commerce in HEU; viz., transaction verification, materials accountability, transportation and environmental safety. The equipment used to carry out the oxidation and blending is simple, inexpensive and highly portable. Mobile facilities to be used for point-of-sale blending and analysis of the product material are presented along with a phased implementation plan that addresses the conversion of HEU derived from domestic weapons and related waste streams as well as material from possible foreign sources such as South Africa or the former Soviet Union.

  14. Method for rapid base sequencing in DNA and RNA

    DOEpatents

    Jett, J.H.; Keller, R.A.; Martin, J.C.; Moyzis, R.K.; Ratliff, R.L.; Shera, E.B.; Stewart, C.C.

    1990-10-09

    A method is provided for the rapid base sequencing of DNA or RNA fragments wherein a single fragment of DNA or RNA is provided with identifiable bases and suspended in a moving flow stream. An exonuclease sequentially cleaves individual bases from the end of the suspended fragment. The moving flow stream maintains the cleaved bases in an orderly train for subsequent detection and identification. In a particular embodiment, individual bases forming the DNA or RNA fragments are individually tagged with a characteristic fluorescent dye. The train of bases is then excited to fluorescence with an output spectrum characteristic of the individual bases. Accordingly, the base sequence of the original DNA or RNA fragment can be reconstructed. 2 figs.

  15. Method for rapid base sequencing in DNA and RNA

    DOEpatents

    Jett, James H.; Keller, Richard A.; Martin, John C.; Moyzis, Robert K.; Ratliff, Robert L.; Shera, E. Brooks; Stewart, Carleton C.

    1990-01-01

    A method is provided for the rapid base sequencing of DNA or RNA fragments wherein a single fragment of DNA or RNA is provided with identifiable bases and suspended in a moving flow stream. An exonuclease sequentially cleaves individual bases from the end of the suspended fragment. The moving flow stream maintains the cleaved bases in an orderly train for subsequent detection and identification. In a particular embodiment, individual bases forming the DNA or RNA fragments are individually tagged with a characteristic fluorescent dye. The train of bases is then excited to fluorescence with an output spectrum characteristic of the individual bases. Accordingly, the base sequence of the original DNA or RNA fragment can be reconstructed.

  16. Method for rapid base sequencing in DNA and RNA

    DOEpatents

    Jett, J.H.; Keller, R.A.; Martin, J.C.; Moyzis, R.K.; Ratliff, R.L.; Shera, E.B.; Stewart, C.C.

    1987-10-07

    A method is provided for the rapid base sequencing of DNA or RNA fragments wherein a single fragment of DNA or RNA is provided with identifiable bases and suspended in a moving flow stream. An exonuclease sequentially cleaves individual bases from the end of the suspended fragment. The moving flow stream maintains the cleaved bases in an orderly train for subsequent detection and identification. In a particular embodiment, individual bases forming the DNA or RNA fragments are individually tagged with a characteristic fluorescent dye. The train of bases is then excited to fluorescence with an output spectrum characteristic of the individual bases. Accordingly, the base sequence of the original DNA or RNA fragment can be reconstructed. 2 figs.

  17. A rapid protection switching method in carrier ethernet ring networks

    NASA Astrophysics Data System (ADS)

    Yuan, Liang; Ji, Meng

    2008-11-01

    Abstract: Ethernet is the most important Local Area Network (LAN) technology since more than 90% data traffic in access layer is carried on Ethernet. From 10M to 10G, the improving Ethernet technology can be not only used in LAN, but also a good choice for MAN even WAN. MAN are always constructed in ring topology because the ring network could provide resilient path protection by using less resource (fibre or cable) than other network topologies. In layer 2 data networks, spanning tree protocol (STP) is always used to protect transmit link and preventing the formation of logic loop in networks. However, STP cannot guarantee the efficiency of service convergence when link fault happened. In fact, convergent time of networks with STP is about several minutes. Though Rapid Spanning Tree Protocol (RSTP) and Multi-Spanning Tree Protocol (MSTP) improve the STP technology, they still need a couple of seconds to achieve convergence, and can not provide sub-50ms protection switching. This paper presents a novel rapid ring protection method (RRPM) for carrier Ethernet. Unlike other link-fault detection method, it adopts distributed algorithm to detect link fault rapidly (sub-50ms). When networks restore from link fault, it can revert to the original working state. RRPM can provide single ring protection and interconnected ring protection without the formation of super loop. In normal operation, the master node blocks the secondary port for all non-RRPM Ethernet frames belonging to the given RRPM Ring, thereby avoiding a loop in the ring. When link fault happens, the node on which the failure happens moves from the "ring normal" state to the "ring fault" state. It also sends "link down" frame immediately to other nodes and blocks broken port and flushes its forwarding database. Those who receive "link down" frame will flush forwarding database and master node should unblock its secondary port. When the failure restores, the whole ring will revert to the normal state. That is

  18. Laboratory diagnosis of malaria: conventional and rapid diagnostic methods.

    PubMed

    Wilson, Michael L

    2013-06-01

    The global control of malaria is more challenging than that of many other infectious diseases: malaria is vector borne, it is caused by 5 species of Plasmodium with different geographic distributions, infection is widespread in many regions, drug resistance is common, and the disease overlaps clinically with other infectious diseases. Therefore, malaria control programs, in addition to diagnosis and testing, must also target limiting spread of the disease through vector control. Although malaria control efforts have been successful in some regions, malaria remains one of the most important causes of death in sub-Saharan Africa, particularly in women and children. To review the current literature regarding diagnostic methods available to detect clinical malaria, with an emphasis on comparing the strengths and limitations of each method. Current World Health Organization malaria control report and other information, recent meta-analyses of diagnostic tests, primary literature concerning the performance characteristics of different tests, and primary literature concerning how diagnostic tests are used in daily practice. The most commonly used method for identifying cases of malaria remains microscopic examination of peripheral blood, but there is growing use of malaria rapid diagnostic tests in many regions. One of the most important findings in the recent literature is that despite the widespread use of diagnostic tests, treatment is too often based on clinical findings rather than on results of diagnostic tests.

  19. A New Rapid Method for Measuring the Vertical Head Profile.

    PubMed

    Keller, Carl

    2017-03-01

    This study describes a new technique for measuring the head profile in a geologic formation. The technique provides rapid, low cost information on the depth of water-producing zones and aquitards in heterogeneous aquifers, yielding estimates of hydraulic heads in each zone while identifying any potential for cross contamination between zones. The measurements can be performed in a typical borehole in just a few hours. The procedure uses both the continuous transmissivity profile obtained by the installation (eversion) of a flexible borehole liner into an open borehole and the subsequent removal (inversion) of the same liner from the borehole. The method is possible because of the continuous transmissivity profile (T profile described by Keller et al. 2014) obtained by measuring the rate of liner eversion under a constant driving head. The hydraulic heads of producing zones are measured using the reverse head profile (RHP) method (patent no. 9,008,971) based on a stepwise inversion of the borehole liner. As each interval of the borehole is uncovered by inversion of the liner, the head beneath the liner is allowed to equilibrate to a steady-state value. The individual hydraulic heads contributing to each measurement are calculated using the measured transmissivity for each zone. Application of the RHP method to a sedimentary bedrock borehole in New Jersey verified that it reproduced the head distribution obtained the same day in the same borehole instrumented with a multilevel sampling system.

  20. Extended- and Point-Source Radiometric Program

    DTIC Science & Technology

    1962-08-08

    Radiometric Measurements of Cs1 37 Sources Made with NaI Detector. . 60 6.2 Aerial Radiometric Measurements of Co 60 Sources Made with Bioplastic ...Hanford aircraft consisted of an NaI scintillator, bioplastic scintillator, and a 40-liter ionization chamber. The aircraft employed was a twin-engine...supply, amplifier, and count rate, was transistorized portable equipment designed and fabricated at Hanford. The bioplastic instrument consisted of a 5

  1. In vivo osteogenesis assay: a rapid method for quantitative analysis.

    PubMed

    Dennis, J E; Konstantakos, E K; Arm, D; Caplan, A I

    1998-08-01

    A quantitative in vivo osteogenesis assay is a useful tool for the analysis of cells and bioactive factors that affect the amount or rate of bone formation. There are currently two assays in general use for the in vivo assessment of osteogenesis by isolated cells: diffusion chambers and porous calcium phosphate ceramics. Due to the relative ease of specimen preparation and reproducibility of results, the porous ceramic assay was chosen for the development of a rapid method for quantitating in vivo bone formation. The ceramic cube implantation technique consists of combining osteogenic cells with 27-mm3 porous calcium phosphate ceramics, implanting the cell-ceramic composites subcutaneously into an immuno-tolerant host, and, after 2-6 weeks, harvesting and preparing the ceramic implants for histologic analysis. A drawback to the analysis of bone formation within these porous ceramics is that the entire cube must be examined to find small foci of bone present in some samples; a single cross-sectional area is not representative. For this reason, image analysis of serial sections from ceramics is often prohibitively time-consuming. Two alternative scoring methodologies were tested and compared to bone volume measurements obtained by image analysis. The two subjective scoring methods were: (1) Bone Scale: the amount of bone within pores of the ceramic implant is estimated on a scale of 0-4 based on the degree of bone fill (0=no bone, 1=up to 25%, 2=25 to 75%, 4=75 to 100% fill); and (2) Percentage Bone: the amount of bone is estimated by determining the percentage of ceramic pores which contain bone. Every tenth section of serially sectioned cubes was scored by each of these methods under double-blind conditions, and the Bone Scale and Percentage Bone results were directly compared to image analysis measurements from identical samples. Correlation coefficients indicate that the Percentage Bone method was more accurate than the Bone Scale scoring method. The Bone Scale

  2. Radiometric calibration updates to the Landsat collection

    NASA Astrophysics Data System (ADS)

    Micijevic, Esad; Haque, Md. Obaidul; Mishra, Nischal

    2016-09-01

    The Landsat Project is planning to implement a new collection management strategy for Landsat products generated at the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center. The goal of the initiative is to identify a collection of consistently geolocated and radiometrically calibrated images across the entire Landsat archive that is readily suitable for time-series analyses. In order to perform an accurate land change analysis, the data from all Landsat sensors must be on the same radiometric scale. Landsat 7 Enhanced Thematic Mapper Plus (ETM+) is calibrated to a radiance standard and all previous sensors are cross-calibrated to its radiometric scale. Landsat 8 Operational Land Imager (OLI) is calibrated to both radiance and reflectance standards independently. The Landsat 8 OLI reflectance calibration is considered to be most accurate. To improve radiometric calibration accuracy of historical data, Landsat 1-7 sensors also need to be cross-calibrated to the OLI reflectance scale. Results of that effort, as well as other calibration updates including the absolute and relative radiometric calibration and saturated pixel replacement for Landsat 8 OLI and absolute calibration for Landsat 4 and 5 Thematic Mappers (TM), will be implemented into Landsat products during the archive reprocessing campaign planned within the new collection management strategy. This paper reports on the planned radiometric calibration updates to the solar reflective bands of the new Landsat collection.

  3. LANDSAT-4 multispectral scanner (MSS) subsystem radiometric characterization

    NASA Technical Reports Server (NTRS)

    Alford, W. (Editor); Barker, J. (Editor); Clark, B. P.; Dasgupta, R.

    1983-01-01

    The multispectral band scanner (mass) and its spectral characteristics are described and methods are given for relating video digital levels on computer compatible tapes to radiance into the sensor. Topics covered include prelaunch calibration procedures and postlaunch radiometric processng. Examples of current data resident on the MSS image processing system are included. The MSS on LANDSAT 4 is compared with the scanners on earlier LANDSAT satellites.

  4. Rapid Tooling Method for Soft Customized Removable Oral Appliances

    PubMed Central

    Salmi, Mika; Tuomi, Jukka; Sirkkanen, Rauno; Ingman, Tuula; Mäkitie, Antti

    2012-01-01

    Traditionally oral appliances i.e. removable orthodontic appliances, bite splints and snoring / sleep apnea appliances are made with alginate impressions and wax registrations. Our aim was to describe the process of manufacturing customized oral appliances with a new technique i.e. rapid tooling method. The appliance should ideally be custom made to match the teeth. An orthodontic patient, scheduled for conventional orthodontic treatment, served as a study subject. After a precise clinical and radiographic examination, the approach was to digitize the patient’s dental arches and then to correct them virtually by computer. Additive manufacturing was then used to fabricate a mould for a soft customized appliance. The mould was manufactured using stereolithography from Somos ProtoGen O-XT 18420 material. Casting material for the mould to obtain the final appliance was silicone. As a result we managed to create a customized soft orthodontic appliance. Also, the accuracy of the method was found to be adequate. Two versions of the described device were manufactured: one with small and one with moderate orthodontic force. The study person also gave information on the subjective patient adaptation aspects of the oral appliance. PMID:22615719

  5. Rapid tooling method for soft customized removable oral appliances.

    PubMed

    Salmi, Mika; Tuomi, Jukka; Sirkkanen, Rauno; Ingman, Tuula; Mäkitie, Antti

    2012-01-01

    Traditionally oral appliances i.e. removable orthodontic appliances, bite splints and snoring / sleep apnea appliances are made with alginate impressions and wax registrations. Our aim was to describe the process of manufacturing customized oral appliances with a new technique i.e. rapid tooling method. The appliance should ideally be custom made to match the teeth. An orthodontic patient, scheduled for conventional orthodontic treatment, served as a study subject. After a precise clinical and radiographic examination, the approach was to digitize the patient's dental arches and then to correct them virtually by computer. Additive manufacturing was then used to fabricate a mould for a soft customized appliance. The mould was manufactured using stereolithography from Somos ProtoGen O-XT 18420 material. Casting material for the mould to obtain the final appliance was silicone. As a result we managed to create a customized soft orthodontic appliance. Also, the accuracy of the method was found to be adequate. Two versions of the described device were manufactured: one with small and one with moderate orthodontic force. The study person also gave information on the subjective patient adaptation aspects of the oral appliance.

  6. Rapid and robust detection methods for poison and microbial contamination.

    PubMed

    Hoehl, Melanie M; Lu, Peter J; Sims, Peter A; Slocum, Alexander H

    2012-06-27

    Real-time on-site monitoring of analytes is currently in high demand for food contamination, water, medicines, and ingestible household products that were never tested appropriately. Here we introduce chemical methods for the rapid quantification of a wide range of chemical and microbial contaminations using a simple instrument. Within the testing procedure, we used a multichannel, multisample, UV-vis spectrophotometer/fluorometer that employs two frequencies of light simultaneously to interrogate the sample. We present new enzyme- and dye-based methods to detect (di)ethylene glycol in consumables above 0.1 wt % without interference and alcohols above 1 ppb. Using DNA intercalating dyes, we can detect a range of pathogens ( E. coli , Salmonella , V. Cholera, and a model for Malaria) in water, foods, and blood without background signal. We achieved universal scaling independent of pathogen size above 10(4) CFU/mL by taking advantage of the simultaneous measurement at multiple wavelengths. We can detect contaminants directly, without separation, purification, concentration, or incubation. Our chemistry is stable to ± 1% for >3 weeks without refrigeration, and measurements require <5 min.

  7. Rapid simulation of spatial epidemics: a spectral method.

    PubMed

    Brand, Samuel P C; Tildesley, Michael J; Keeling, Matthew J

    2015-04-07

    Spatial structure and hence the spatial position of host populations plays a vital role in the spread of infection. In the majority of situations, it is only possible to predict the spatial spread of infection using simulation models, which can be computationally demanding especially for large population sizes. Here we develop an approximation method that vastly reduces this computational burden. We assume that the transmission rates between individuals or sub-populations are determined by a spatial transmission kernel. This kernel is assumed to be isotropic, such that the transmission rate is simply a function of the distance between susceptible and infectious individuals; as such this provides the ideal mechanism for modelling localised transmission in a spatial environment. We show that the spatial force of infection acting on all susceptibles can be represented as a spatial convolution between the transmission kernel and a spatially extended 'image' of the infection state. This representation allows the rapid calculation of stochastic rates of infection using fast-Fourier transform (FFT) routines, which greatly improves the computational efficiency of spatial simulations. We demonstrate the efficiency and accuracy of this fast spectral rate recalculation (FSR) method with two examples: an idealised scenario simulating an SIR-type epidemic outbreak amongst N habitats distributed across a two-dimensional plane; the spread of infection between US cattle farms, illustrating that the FSR method makes continental-scale outbreak forecasting feasible with desktop processing power. The latter model demonstrates which areas of the US are at consistently high risk for cattle-infections, although predictions of epidemic size are highly dependent on assumptions about the tail of the transmission kernel.

  8. Transportable high sensitivity small sample radiometric calorimeter

    SciTech Connect

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-12-31

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most {sup 238}Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size.

  9. Antimicrobial susceptibility of rapidly growing mycobacteria using the rapid colorimetric method.

    PubMed

    Ramis, I B; Cnockaert, M; von Groll, A; Nogueira, C L; Leão, S C; Andre, E; Simon, A; Palomino, J C; da Silva, P E A; Vandamme, P; Martin, A

    2015-07-01

    Drug susceptibility testing (DST) of rapidly growing mycobacteria (RGM) are recommended for guiding the antimicrobial therapy. We have evaluated the use of resazurin in Mueller-Hinton medium (MHR) for MIC determination of RGM and compared the results with those obtained with the reference standard broth microdilution in Mueller-Hinton (MH) and with the resazurin microtiter assay (REMA) in 7H9 broth. The MIC of eight drugs: amikacin (AMI), cefoxitin (FOX), ciprofloxacin (CIP), clarithromycin (CLA), doxycycline (DOX), linezolid (LZD), moxifloxacin (MXF) and trimethoprim-sulfamethoxazole (TMP-SMX) were evaluated against 76 RGM (18 species) using three methods (MH, MHR, and REMA) in a 96-well plate format incubated at 37 °C over 3-5 days. Results obtained in the MH plates were interpreted by the appearance of turbidity at the bottom of the well before adding the resazurin. MHR and 7H9-REMA plates were read by visual observation for a change in color from blue to pink. The majority of results were obtained at day 5 for MH and 1 day after for MHR and 7H9-REMA. However, the preliminary experiment on time to positivity results using the reference strain showed that the resazurin can be added to the MH at day 2 to produce the results at day 3, but future studies with large sets of strains are required to confirm this suggestion. A high level of agreement (kappa 1.000-0.884) was obtained between the MH and the MHR. Comparison of results obtained with 7H9-REMA, on the other hand, revealed several discrepancies and a lower level of agreement (kappa 1.000-0.111). The majority of the strains were resistant to DOX and TMP-SMX, and the most active antimicrobials for RGM were AMI and FOX. In the present study, MHR represented an excellent alternative for MIC determination of RGM. The results could be read reliably, more easily, and more quickly than with the classical MH method.

  10. Radiometric calibration of tempospatially modulated polarization interference imaging spectrometer.

    PubMed

    Gao, Peng; Ai, Jingjing; Zhang, Chunmin

    2016-12-10

    The tempospatially modulated polarization interference imaging spectrometer (TSMPIIS) nominated by the Ministry of Scence and Technology, takes part in the "Eleventh Five-Year National Science and Technology Exhibition." In order to improve the detecting precision of the TSMPIIS, its radiometric calibration scheme is proposed on the basis of the solar simulator, integrating sphere, monochromator, and spectroradiometer. Under the conditions of changing the exposure time and radiant brightness, the CCD linear responses for the TSMPIIS were first tested to validate the reliability of the radiometric calibration performed with a linear response model, and the linear errors were less than 0.15% and 1.15%, respectively. A novel method is put forward to calibrate the nonuniformity of CCD pixels, and the least squares method can commendably correct the uneven effect in the spatial direction. Besides, the absolute radiometric calibration establishes a corresponding relation between the dimensionless intensity output from the TSMPIIS and the target radiant brightness. The study lays the foundation for the engineering application of the TSMPIIS, such as remote sensing detection, and has an important significance for the development of our instrument and equipment technology with independent intellectual property rights.

  11. Radiometric dating of the Siloam Tunnel, Jerusalem.

    PubMed

    Frumkin, Amos; Shimron, Aryeh; Rosenbaum, Jeff

    2003-09-11

    The historical credibility of texts from the Bible is often debated when compared with Iron Age archaeological finds (refs. 1, 2 and references therein). Modern scientific methods may, in principle, be used to independently date structures that seem to be mentioned in the biblical text, to evaluate its historical authenticity. In reality, however, this approach is extremely difficult because of poor archaeological preservation, uncertainty in identification, scarcity of datable materials, and restricted scientific access into well-identified worship sites. Because of these problems, no well-identified Biblical structure has been radiometrically dated until now. Here we report radiocarbon and U-Th dating of the Siloam Tunnel, proving its Iron Age II date; we conclude that the Biblical text presents an accurate historic record of the Siloam Tunnel's construction. Being one of the longest ancient water tunnels lacking intermediate shafts, dating the Siloam Tunnel is a key to determining where and when this technological breakthrough took place. Siloam Tunnel dating also refutes a claim that the tunnel was constructed in the second century bc.

  12. Novel techniques for the analysis of the TOA radiometric uncertainty

    NASA Astrophysics Data System (ADS)

    Gorroño, Javier; Banks, Andrew; Gascon, Ferran; Fox, Nigel P.; Underwood, Craig I.

    2016-10-01

    In the framework of the European Copernicus programme, the European Space Agency (ESA) has launched the Sentinel-2 (S2) Earth Observation (EO) mission which provides optical high spatial -resolution imagery over land and coastal areas. As part of this mission, a tool (named S2-RUT, from Sentinel-2 Radiometric Uncertainty Tool) estimates the radiometric uncertainties associated to each pixel using as input the top-of-atmosphere (TOA) reflectance factor images provided by ESA. The initial version of the tool has been implemented — code and user guide available1 — and integrated as part of the Sentinel Toolbox. The tool required the study of several radiometric uncertainty sources as well as the calculation and validation of the combined standard uncertainty in order to estimate the TOA reflectance factor uncertainty per pixel. Here we describe the recent research in order to accommodate novel uncertainty contributions to the TOA reflectance uncertainty estimates in future versions of the tool. The two contributions that we explore are the radiometric impact of the spectral knowledge and the uncertainty propagation of the resampling associated to the orthorectification process. The former is produced by the uncertainty associated to the spectral calibration as well as the spectral variations across the instrument focal plane and the instrument degradation. The latter results of the focal plane image propagation into the provided orthoimage. The uncertainty propagation depends on the radiance levels on the pixel neighbourhood and the pixel correlation in the temporal and spatial dimensions. Special effort has been made studying non-stable scenarios and the comparison with different interpolation methods.

  13. Rapid Methods for the Laboratory Identification of Pathogenic Microorganisms.

    DTIC Science & Technology

    1982-09-01

    reveree aide If neceeeary and Identify by block number) Lectins: Rapid Identification, Bacillus anthracisjCryptococcus " neoformans. Neisseria...field-type kit for the rapid identification of Bacillus anthracis. We have shown that certain lectins will selectively interact with B. anthracis...but not with other species of the Bacillus genus. This finding provides the basis for devising more sensitive assays, such as an enzyme-linked

  14. User's guide to the Radiometric Age Data Bank (RADB)

    USGS Publications Warehouse

    Zartman, Robert Eugene; Cole, James C.; Marvin, Richard F.

    1976-01-01

    The Radiometric Age Data Bank (RADB) has been established by the U.S. Geological Survey, as a means for collecting and organizing the estimated 100,000 radiometric ages presently published for the United States. RADB has been constructed such that a complete sample description (location, rock type, etc.), literature citation, and extensive analytical data are linked to form an independent record for each sample reported in a published work. Analytical data pertinent to the potassium-argon, rubidium-strontium, uranium-thorium-lead, lead-alpha, and fission-track methods can be accommodated, singly or in combinations, for each record. Data processing is achieved using the GIPSY program (University of Oklahoma) which maintains the data file and builds, updates, searches, and prints the records using simple yet versatile command statements. Searching and selecting records is accomplished by specifying the presence, absence, or (numeric or alphabetic) value of any element of information in the data bank, and these specifications can be logically linked to develop sophisticated searching strategies. Output is available in the form of complete data records, abbreviated tests, or columnar tabulations. Samples of data-reporting forms, GIPSY command statements, output formats, and data records are presented to illustrate the comprehensive nature and versatility of the Radiometric Age Data Bank.

  15. Granite petrogenesis revealed by combined gravimetric and radiometric imaging

    NASA Astrophysics Data System (ADS)

    Tartèse, Romain; Boulvais, Philippe; Poujol, Marc; Vigneresse, Jean-Louis

    2011-03-01

    In peneplaned terranes, it is often impossible to get a full 3D view of geological objects. In the case of granitic plutons, for which intrusive relationships between constituent units can provide first order information regarding their petrogenesis, this lack of 3D field evidence is a major issue. Indirect observations can be provided by geophysical surveys. Here, we interpret field gravity data and airborne gamma ray radiometric maps with whole rock geochemistry data in order to obtain information on granite petrogenesis. First, we test our proposed combined geophysical and geochemical approach on the Huelgoat Variscan intrusion (Armorican Massif, France) and we show that ternary radiometric maps are a good proxy for the distribution of K, U and Th radioelements. Then, we apply our method to the Lizio and Questembert Variscan granitic intrusions (Armorican Massif) and show that some features characteristic of the intrusions, such as the feeding zones, can be localised by geophysical imaging. Indeed, radiometric maps constitute a frozen image of the latest stage of the magmatic building of plutons.

  16. Milestones: a rapid assessment method for the Clinical Competency Committee

    PubMed Central

    Nabors, Christopher; Forman, Leanne; Peterson, Stephen J.; Gennarelli, Melissa; Aronow, Wilbert S.; DeLorenzo, Lawrence; Chandy, Dipak; Ahn, Chul; Sule, Sachin; Stallings, Gary W.; Khera, Sahil; Palaniswamy, Chandrasekar; Frishman, William H.

    2016-01-01

    Introduction Educational milestones are now used to assess the developmental progress of all U.S. graduate medical residents during training. Twice annually, each program’s Clinical Competency Committee (CCC) makes these determinations and reports its findings to the Accreditation Council for Graduate Medical Education (ACGME). The ideal way to conduct the CCC is not known. After finding that deliberations reliant upon the new milestones were time intensive, our internal medicine residency program tested an approach designed to produce rapid but accurate assessments. Material and methods For this study, we modified our usual CCC process to include pre-meeting faculty ratings of resident milestones progress with in-meeting reconciliation of their ratings. Data were considered largely via standard report and presented in a pre-arranged pattern. Participants were surveyed regarding their perceptions of data management strategies and use of milestones. Reliability of competence assessments was estimated by comparing pre-/post-intervention class rank lists produced by individual committee members with a master class rank list produced by the collective CCC after full deliberation. Results Use of the study CCC approach reduced committee deliberation time from 25 min to 9 min per resident (p < 0.001). Committee members believed milestones improved their ability to identify and assess expected elements of competency development (p = 0.026). Individual committee member assessments of trainee progress agreed well with collective CCC assessments. Conclusions Modification of the clinical competency process to include pre-meeting competence ratings with in-meeting reconciliation of these ratings led to shorter deliberation times, improved evaluator satisfaction and resulted in reliable milestone assessments. PMID:28144272

  17. Rapid Methods of Staining Bacterial Spores at Room Temperature

    PubMed Central

    Lechtman, M. D.; Bartholomew, J. W.; Phillips, A.; Russo, M.

    1965-01-01

    Lechtman, M. D. (University of Southern California, Los Angeles), J. W. Bartholomew, A. Phillips, and M. Russo. Rapid methods of staining bacterial spores at room temperature. J. Bacteriol. 89:848–854. 1965.—Spores of Bacillus subtilis var. niger were stained in 2 min at room temperature, after suitable pretreatment, with a dye reagent composed of 2% crystal violet in 1% phenol and 26% ethanol. Pretreatments included heat fixation to 260 C, mechanical rupture, and hydrolysis at room temperature in 44 n H3PO4 for 5 min, 33.4 n H3PO4 for 10 min, 12 n HCl for 5 sec, 6 n HCl for 2 min, 12 n HNO3 for 5 sec, and 6 n HNO3 for 60 sec. Acid hydrolysis at 60 C enabled the lowering of both acid concentration and time: 33.4 n H3PO4 for 15 sec, 25.9 n H3PO4 for 60 sec, 2 n HCl for 30 sec, 1 n HCl for 30 sec, 2 n HNO3 for 15 sec, and 1 n HNO3 for 30 sec. After acid treatment, 1 n NaOH was used as a neutralization agent. The cytological manifestations of these pretreatments, examined in an electron microscope after replication, showed definite degradation of spore coats, which probably explains the increase in dye permeability. The pretreatments were evaluated for use in a differential staining procedure for spores and vegetative cells. They were found to be too drastic in that they resulted in replacement of the primary dye by the 0.25% safranine counter stain in both vegetative cells and endospores. Less drastic pretreatments, such as 6 n HNO3 for 10 sec at room temperature, gave good differential stains, but failed to stain some free spores. The staining techniques above were evaluated with six species of Bacillus and were found to apply to all. Images PMID:14273671

  18. A rapid method for breath analysis in cystic fibrosis patients.

    PubMed

    Kramer, R; Sauer-Heilborn, A; Welte, T; Guzman, C A; Höfle, M G; Abraham, W-R

    2015-04-01

    For easy handling and speed of lung diseases diagnostics, approaches based on volatile organic compounds (VOCs), including those emitted by pathogenic microorganisms, are considered but currently require considerable sampling efforts. We tested whether easy-to-handle and fast detection of lung infections is possible using solid-phase microextraction (SPME) of 100 ml of exhaled breath. An analytical procedure for the detection of VOCs from the headspace of epithelial lung cells infected with four human pathogens was developed. The feasibility of this method was tested in a cystic fibrosis (CF) outpatient clinic in vivo. Exhaled breath was extracted by SPME and analyzed by gas chromatography-mass spectrometry (GC-MS). The compositions of VOCs released in the infection model were characteristic for all individual pathogens tested. Exhaled breath of CF patients allowed clear distinction of CF patients and controls by their VOC compositions using multivariate analyses. Interestingly, the major specific VOCs detected in the exhaled breath of infected CF patients in vivo differed from those monitored during bacterial in vitro growth. SPME extraction of VOCs from 100 ml of human breath allowed the distinction between CF patients and healthy probands. Our results highlight the importance of assessing the entire pattern of VOCs instead of selected biomarkers for diagnostic purposes, as well as the need to use clinical samples to identify reliable biomarkers. This study provides the proof-of-concept for the approach using the composition of exhaled VOCs in human breath for the rapid identification of infectious agents in patients with lower respiratory tract infections.

  19. A new rapid method for rockfall energies and distances estimation

    NASA Astrophysics Data System (ADS)

    Giacomini, Anna; Ferrari, Federica; Thoeni, Klaus; Lambert, Cedric

    2016-04-01

    and distances at the base to block and slope features. The validation of the proposed approach was conducted by comparing predictions to experimental data collected in the field and gathered from the scientific literature. The method can be used for both natural and constructed slopes and easily extended to more complicated and articulated slope geometries. The study shows its great potential for a quick qualitative hazard assessment providing indication about impact energy and horizontal distance of the first impact at the base of a rock cliff. Nevertheless, its application cannot substitute a more detailed quantitative analysis required for site-specific design of mitigation measures. Acknowledgements The authors gratefully acknowledge the financial support of the Australian Coal Association Research Program (ACARP). References Dorren, L.K.A. (2003) A review of rockfall mechanics and modelling approaches, Progress in Physical Geography 27(1), 69-87. Agliardi, F., Crosta, G.B., Frattini, P. (2009) Integrating rockfall risk assessment and countermeasure design by 3D modelling techniques. Natural Hazards and Earth System Sciences 9(4), 1059-1073. Ferrari, F., Thoeni, K., Giacomini, A., Lambert, C. (2016) A rapid approach to estimate the rockfall energies and distances at the base of rock cliffs. Georisk, DOI: 10.1080/17499518.2016.1139729.

  20. Dry rehydratable film method for rapid enumeration of coliforms in foods (3M Petrifilm Rapid Coliform Count plate): collaborative study.

    PubMed

    Kinneberg, Karen M; Lindberg, Kathryn G

    2002-01-01

    A rehydratable dry-film plating method for coliforms in foods, the 3M Petrifilm Rapid Coliform Count plate method, was compared with the U.S. Food and Drug Administration's Bacteriological Analytical Manual method for nondairy foods and the American Public Health Association's Standard Methods for the Examination of Dairy Products (SMEDP) method for dairy foods. Six food types, vanilla ice cream, cheddar cheese, fresh refrigerated uncooked pasta, wheat flour, prepared frozen macaroni and cheese, and frozen hash browns, were analyzed for coliforms by 11 collaborating laboratories. For each food product tested, the collaborators received 8 blind samples consisting of a control sample and 3 levels of inoculated sample, each in duplicate. The mean log counts for the methods were comparable. The repeatability and reproducibility variances of the Petrifilm Rapid Coliform Count method at 14 and 24 h were not significantly different from those of the standard methods.

  1. A multi-channel radiometric profiler of temperature, humidity and cloud liquid.

    SciTech Connect

    Ware, R.; Carpenter, R.; Guldner, J.; Liljegren, J.; Nehrkorn, T.; Solheim, F.; Vandenberghe, F.; Environmental Research; Radiometrics Corp.; Univ. Corp. for Atmospheric Research; Weather Decision Technologies Inc.; Atmospheric and Environmental Research Inc.; National Center for Atmospheric Research

    2003-07-31

    A microwave radiometer is described that provides continuous thermodynamic (temperature, water vapor, and moisture) soundings during clear and cloudy conditions. The radiometric profiler observes radiation intensity at 12 microwave frequencies, along with zenith infrared and surface meteorological measurements. Historical radiosonde and neural network or regression methods are used for profile retrieval. We compare radiometric, radiosonde, and forecast soundings and evaluate the accuracy of radiometric temperature and water vapor soundings on the basis of statistical comparison with radiosonde soundings. We find that radiometric soundings are equivalent in accuracy to radiosonde soundings when used in numerical weather forecasting. A case study is described that demonstrates improved fog forecasting on the basis of variational assimilation of radiometric soundings. The accuracy of radiometric cloud liquid soundings is evaluated by comparison with cloud liquid sensors carried by radiosondes. Accurate high-resolution three-dimensional water vapor and wind analysis is described on the basis of assimilation of simulated thermodynamic and wind soundings along with GPS slant delays. Examples of mobile thermodynamic and wind profilers are shown. Thermodynamic profiling, particularly when combined with wind profiling and slant GPS, provides continuous atmospheric soundings for improved weather and dispersion forecasting.

  2. A radiometric assay for bacterial growth detection and quantitative antibiotic testing

    SciTech Connect

    Boonkitticharoen, V.; Kirchner, P.T.; Ehrhardt, J.C.

    1984-01-01

    Buddemeyer's two-compartment radiometric assay for bacterial growth using respired C-14 carbon dioxide promised major advantages over other available methods, but limitations of the technique have restricted its application. Through a systemic study of relevant physical and chemical factors the authors sought to improve the assay for earlier detection of bacterial growth and to extend its use to measurement of antibiotic drug susceptibility and potency. A 35-fold improvement in count rate response was achieved by a) reversing growth and detector chambers to permit rigorous agitation, b) increasing NaOH quantity and using a supersaturated PPO solution, and c) adding detergent to stabilize NaOH-PPO contact. Bacterial growth may be detected as early as 1/2 hour after inoculation. For rapidly growing bacteria the growth rate constant is defined as the slope of the growth curve (log count rate vs. time). The validity of the growth behavior was verified by measuring growth at several inoculum sizes over 3 orders of magnitude using standard strains of S. aureus and E. coli. The growth rate constant proved to be independent of inoculum size. To test the merit of the system as an antibiotic assay, E. coli were exposed to doses of spectinomycin hydrochloride in the range which yielded a nonlinear dose-response relation by a turbidity assay. The test, however, showed a linear relation between growth rate constant and antibiotic dose. The results clearly indicate the radiometric growth rate assay to be a rapid, valid and objective assay for bacterial growth and antibiotic sensitivity.

  3. AIRS radiometric calibration validation for climate research

    NASA Technical Reports Server (NTRS)

    Aumann, Hartmut H.; Pagano, Thomas S.; Elliott, Denis; Gaiser, Steve; Gregorich, Dave; Broberg, Steve

    2005-01-01

    Climate research using data from satellite based radiometers makes extreme demands on the traceability and stability of the radiometric calibration. The selection of a cooled grating array spectrometer for the Atmospheric Infrared Sounder, AIRS, is key, but does not ensured that AIRS data will be of climate quality. Additional design features, plus additional pre-launch testing, and extensive on-orbit calibration subsystem monitoring beyond what would suffice for application of the data to weather forecasting were required to ensure the radiometric data quality required for climate research. Validation that climate data quality are being generated makes use of the sea surface skin temperatures (SST and (obs-calc).

  4. Radiometric selective inhibition tests for differentiation of Mycobacterium tuberculosis, Mycobacterium bovis, and other mycobacteria.

    PubMed Central

    Gross, W M; Hawkins, J E

    1985-01-01

    In the context of a busy reference laboratory, radiometric selective inhibition tests were evaluated for rapid differentiation of Mycobacterium tuberculosis and Mycobacterium bovis and of the M. tuberculosis complex from other mycobacteria. p-Nitro-alpha-acetylamino-beta-hydroxypropiophenone at 5 micrograms and hydroxylamine hydrochloride at 62.5 and 125 micrograms per ml of 7H12 medium were used to separate the M. tuberculosis complex from other mycobacteria (MOTT bacilli). Since it is important epidemiologically to distinguish M. tuberculosis from M. bovis, susceptibility to 1 microgram of thiophene-2-carboxylic acid per ml was also determined radiometrically. By using these three agents as selective inhibitors, M. tuberculosis, M. bovis, and MOTT bacilli were differentiated with a high degree of specificity by a BACTEC radiometric procedure. Results of tests performed on clinical isolates submitted on solid medium to our reference laboratory were available within 5 days. PMID:3921561

  5. Evaluation of the Fully Automated BACTEC MGIT 960 System for Testing Susceptibility of Mycobacterium tuberculosis to Pyrazinamide, Streptomycin, Isoniazid, Rifampin, and Ethambutol and Comparison with the Radiometric BACTEC 460TB Method

    PubMed Central

    Scarparo, Claudio; Ricordi, Paolo; Ruggiero, Giuliana; Piccoli, Paola

    2004-01-01

    The performance of the fully automated BACTEC MGIT 960 (M960) system for the testing of Mycobacterium tuberculosis susceptibility to streptomycin (SM), isoniazid (INH), rifampin (RMP), ethambutol (EMB), and pyrazinamide (PZA) was evaluated with 100 clinical isolates and compared to that of the radiometric BACTEC 460TB (B460) system. The agar proportion method and the B460 system were used as reference methods to resolve the discordant results for SM, INH, RMP, and EMB (a combination known as SIRE) and PZA, respectively. The overall agreements were 96.3% for SIRE and 92% for PZA. For SIRE, a total of 26 discrepancies were found and were resolved in favor of the M960 system in 8 cases and in favor of the B460 system in 18 cases. The M960 system produced 8 very major errors (VME) and 10 major errors (ME), while the B460 system showed 4 VME and 4 ME. No statistically significant differences were found. Both systems exhibited excellent performance, but a higher number of VME was observed with the M960 system at the critical concentrations of EMB and SM. For PZA, a total of eight discrepancies were observed and were resolved in favor of the M960 system in one case and in favor of the B460 system in seven cases; no statistically significant differences were found. The M960 system showed four VME and three ME. The mean times to report overall PZA results and resistant results were 8.2 and 9.8 days, respectively, for the M960 system and 7.4 and 8.1 days, respectively, for the B460 system. Statistically significant differences were found. The mean times to report SIRE results were 8.3 days for the M960 system and 8.2 days for the B460 system. No statistically significant differences were found. Twelve strains tested for SIRE susceptibility and seven strains tested for PZA susceptibility had been reprocessed because of contamination. In conclusion, the M960 system can represent a valid alternative to the B460 for M. tuberculosis susceptibility testing; however, the frequent

  6. A rapid method to improve protein detection by indirect ELISA

    USDA-ARS?s Scientific Manuscript database

    The enzyme-linked immunosorbant assay (ELISA) is a rapid, high-throughput, quantitative immunoassay for the selective detection of target antigens. The general principle behind an ELISA is antibody mediated capture and detection of an antigen with a measureable substrate. Numerous incarnations of th...

  7. Rapid detection of malaria parasite by toluidine blue method: a new staining method.

    PubMed

    Annam, Vamseedhar; Mohan, Chakkirala Nalini; Mrinalini, Vazhayil Ramunny

    2013-10-01

    Malaria is a commonest mosquito-borne infectious disease worldwide. Early identification and management of malaria prevents complications and mortality. Identification of the malaria mainly relies on detection of the parasite on blood smears. The present study was conducted to compare Toluidine blue method with Leishman method for detection of malaria parasite and also to study the efficacy and advantages of using Toluidine blue method. In 540 consecutive patients with clinical suspicion of malaria, peripheral smears were prepared. Smears were processed for both conventional Leishman method and Toluidine blue method simultaneously. The significance of Toluidine blue method over Leishman method was analyzed using Chi-square (χ(2)) test. Out of 540 smears, 28.3% (153/540) were positive for malaria parasite on conventional Leishman method, while the smear positivity was more by Toluidine blue method to 33.3% (180/540) [P value < 0.01]. The remaining 66.67% (360/540) were negative by both Toluidine blue method and conventional Leishman method. The Toluidine blue method is simple, rapid, inexpensive, and easily available. The implementation of Toluidine blue method clearly improves microscopic detection of malaria parasite and can be a useful contribution to routine hematology even at rural health sectors.

  8. Rapid Radiochemical Method for Radium-226 in Building ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Radium-226 in building materials Method Selected for: SAM lists this method for qualitative analysis of radium-226 in concrete or brick building materials Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  9. Rapid Radiochemical Method for Total Radiostrontium (Sr-90) ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Beta counting Method Developed for: Strontium-89 and strontium-90 in building materials Method Selected for: SAM lists this method for qualitative analysis of strontium-89 and strontium-90 in concrete or brick building materials Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  10. Rapid Radiochemical Method for Americium-241 in Building ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Americium-241 in building materials Method Selected for: SAM lists this method for qualitative analysis of americium-241 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  11. Statistical Methods for Rapid Aerothermal Analysis and Design Technology

    NASA Technical Reports Server (NTRS)

    Morgan, Carolyn; DePriest, Douglas; Thompson, Richard (Technical Monitor)

    2002-01-01

    The cost and safety goals for NASA's next generation of reusable launch vehicle (RLV) will require that rapid high-fidelity aerothermodynamic design tools be used early in the design cycle. To meet these requirements, it is desirable to establish statistical models that quantify and improve the accuracy, extend the applicability, and enable combined analyses using existing prediction tools. The research work was focused on establishing the suitable mathematical/statistical models for these purposes. It is anticipated that the resulting models can be incorporated into a software tool to provide rapid, variable-fidelity, aerothermal environments to predict heating along an arbitrary trajectory. This work will support development of an integrated design tool to perform automated thermal protection system (TPS) sizing and material selection.

  12. Computer Image Analysis Method for Rapid Quantitation of Macrophage Phagocytosis

    DTIC Science & Technology

    1990-01-01

    number of micro- spheres per cell. *Rapid Macrophage Phagocytosis Ouantitatlon 405 analysis system is a Kontron-Zeiss SEM-IPS ( Carl Zeiss, digitizing...re- croscope (Photomicroscope 1I, Carl Zeiss, Inc., Thorn- suiting image was scaled by making grey values from 0 wood, NY) equipped with phase...fidelity of the discrim- lease 4.4 ( Carl Zeiss, Inc., Thornwood, NY) was used to ination was evaluated by overlaying contour maps of the analyze the

  13. Simple and Rapid Method for Detecting Biofilm Forming Bacteria.

    PubMed

    Kalia, Vipin Chandra; Prakash, Jyotsana; Koul, Shikha; Ray, Subhasree

    2017-03-01

    Biofilm forming bacteria play a vital role in causing infectious diseases and for enhancing the efficiency of the bioremediation process through immobilization. Different media and conditions have been reported for detecting biofilm forming bacteria, however, they are not quite rapid. Here, we propose the use of a simple medium which can be used for detecting biofilm former, and also provide a mechanism to regulate the expression of biofilm formation process.

  14. Rapid Methods for the Laboratory Identification of Pathogenic Microorganisms.

    DTIC Science & Technology

    1981-09-01

    Extracts Prepared in our Lab Mimosa seed 4+ 0 + 0 + Mango seed 0 0 1+ 3+ + Sunflower seed 2+ 0 0 + 0 Avocado seed 1+ 3+ 3+ 1+ NT Persimmon seed 4...M. indica extract was prepared from the dried seeds of commercially purchased mangoes. The seeds were pulverized in a CRC micromill and extracted ...panel of 14 lectins and extracts demonstrating lectin-like activity led to the development of a rapid agglu- tination slide test for the

  15. Based on Narcissus of radiometric calibration technology

    NASA Astrophysics Data System (ADS)

    Jin, Libing; Tang, Shaofan; Liu, Jianfeng; Peng, Honggang

    2015-08-01

    Thermal radiation is an inherent property of all objects. Generally, it is believed that the body, which temperature is above absolute zero, can keep generating infrared radiation. Infrared remote sensing, using of satellite-borne or airborne sensors, collects infrared information to identify the surface feature and inversion of surface parameters, temperature, etc. In order to get more accurately feature information, quantitative measurement is required. Infrared radiometric calibration is one of the key technologies of quantitative infrared remote sensing. Most high-resolution thermal imaging systems are cooling. For the infrared optical system which is having a cooled detector, there are some special phenomenons. Since the temperature of the detector's photosensitive surface is generally low, which is very different from system temperature, it is a very strong cold radiation source. Narcissus refers to the case that the cooled detector can "see" its own reflecting image, which may affect the image quality of infrared system seriously. But for radiometric calibration of satellite-borne infrared camera, it can sometimes take advantage of the narcissus instead of cold cryogenic radiometric calibration. In this paper, the use of narcissus to carry out radiometric calibration is summarized, and simulation results show the feasibility.

  16. [Principle of LAMP method--a simple and rapid gene amplification method].

    PubMed

    Ushikubo, Hiroshi

    2004-06-01

    So far nucleic acid test (NAT) has been employed in various fields, including infectious disease diagnoses. However, due to its complicated procedures and relatively high cost, it has not been widely utilized in many actual diagnostic applications. We have therefore developed a simple and rapid gene amplification technology, Loop-mediated Isothermal Amplification (LAMP) method, which has shown prominent results of surpassing the performance of the conventional gene amplification methods. LAMP method acquires three main features: (1) all reaction can be carried out under isothermal conditions; (2) the amplification efficiency is extremely high and tremendous amount of amplification products can be obtained; and (3) the reaction is highly specific. Furthermore, developed from the standard LAMP method, a rapid LAMP method, by adding in the loop primers, can reduce the amplification time from the previous 1 hour to less than 30 minutes. Enormous amount of white precipitate of magnesium pyrophosphate is produced as a by-product of the amplification, therefore, direct visual detection is possible without using any reaction indicators and detection equipments. We believe LAMP technology, with the integration of these features, can rightly apply to clinical genetic testing, food and environmental analysis, as well as NAT in different fields.

  17. Rapid Radiochemical Method for Isotopic Uranium in Building ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Uranium-234, uranium-235, and uranium-238 in concrete and brick samples Method Selected for: SAM lists this method for qualitative analysis of uranium-234, uranium-235, and uranium-238 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  18. Radiometric infrared focal plane array imaging system for thermographic applications

    NASA Technical Reports Server (NTRS)

    Esposito, B. J.; Mccafferty, N.; Brown, R.; Tower, J. R.; Kosonocky, W. F.

    1992-01-01

    This document describes research performed under the Radiometric Infrared Focal Plane Array Imaging System for Thermographic Applications contract. This research investigated the feasibility of using platinum silicide (PtSi) Schottky-barrier infrared focal plane arrays (IR FPAs) for NASA Langley's specific radiometric thermal imaging requirements. The initial goal of this design was to develop a high spatial resolution radiometer with an NETD of 1 percent of the temperature reading over the range of 0 to 250 C. The proposed camera design developed during this study and described in this report provides: (1) high spatial resolution (full-TV resolution); (2) high thermal dynamic range (0 to 250 C); (3) the ability to image rapid, large thermal transients utilizing electronic exposure control (commandable dynamic range of 2,500,000:1 with exposure control latency of 33 ms); (4) high uniformity (0.5 percent nonuniformity after correction); and (5) high thermal resolution (0.1 C at 25 C background and 0.5 C at 250 C background).

  19. Branching Ratios for The Radiometric Calibration of EUNIS-2012

    NASA Technical Reports Server (NTRS)

    Daw, Adrian N.; Bhatia, A. K.; Rabin, Douglas M.

    2012-01-01

    The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket instrument is a two-channel imaging spectrograph that observes the solar corona and transition region with high spectral resolution and a rapid cadence made possible by unprecedented sensitivity. The upcoming flight will incorporate a new wavelength channel covering the range 524-630 Angstroms, the previously-flown 300-370 Angstroms channel, and the first flight demonstration of cooled active pixel sensor (APS) arrays. The new 524-630 Angstrom channel incorporates a Toroidal Varied Line Space (TVLS) grating coated with B4C/Ir, providing broad spectral coverage and a wide temperature range of 0.025 to 10 MK. Absolute radiometric calibration of the two channels is being performed using a hollow cathode discharge lamp and NIST-calibrated AXUV-100G photodiode. Laboratory observations of He I 584 Angstroms and He II 304 Angstroms provide absolute radiometric calibrations of the two channels at those two respective wavelengths by using the AXUV photodiode as a transfer standard. The spectral responsivity is being determined by observing line pairs with a common upper state in the spectra of Ne I-III and Ar II-III. Calculations of A-values for the observed branching ratios are in progress.

  20. A stable, rapidly converging conjugate gradient method for energy minimization

    SciTech Connect

    Watowich, S.J.; Meyer, E.S.; Hagstrom, R.; Josephs, R.

    1989-01-01

    We apply Shanno's conjugate gradient algorithm to the problem of minimizing the potential energy function associated with molecular mechanical calculations. Shanno's algorithm is stable with respect to roundoff errors and inexact line searches and converges rapidly to a minimum. Equally important, this algorithm can improve the rate of convergence to a minimum by a factor of 5 relative to Fletcher-Reeves or Polak-Ribiere minimizers when used within the molecular mechanics package AMBER. Comparable improvements are found for a limited number of simulations when the Polak-Ribiere direction vector is incorporated into the Shanno algorithm. 24 refs., 4 figs., 3 tabs.

  1. A rapid method to estimate Westergren sedimentation rates

    NASA Astrophysics Data System (ADS)

    Alexy, Tamas; Pais, Eszter; Meiselman, Herbert J.

    2009-09-01

    The erythrocyte sedimentation rate (ESR) is a nonspecific but simple and inexpensive test that was introduced into medical practice in 1897. Although it is commonly utilized in the diagnosis and follow-up of various clinical conditions, ESR has several limitations including the required 60 min settling time for the test. Herein we introduce a novel use for a commercially available computerized tube viscometer that allows the accurate prediction of human Westergren ESR rates in as little as 4 min. Owing to an initial pressure gradient, blood moves between two vertical tubes through a horizontal small-bore tube and the top of the red blood cell (RBC) column in each vertical tube is monitored continuously with an accuracy of 0.083 mm. Using data from the final minute of a blood viscosity measurement, a sedimentation index (SI) was calculated and correlated with results from the conventional Westergren ESR test. To date, samples from 119 human subjects have been studied and our results indicate a strong correlation between SI and ESR values (R2=0.92). In addition, we found a close association between SI and RBC aggregation indices as determined by an automated RBC aggregometer (R2=0.71). Determining SI on human blood is rapid, requires no special training and has minimal biohazard risk, thus allowing physicians to rapidly screen for individuals with elevated ESR and to monitor therapeutic responses.

  2. A rapid method for hydraulic profiling in unconsolidated formations

    USGS Publications Warehouse

    Dietrich, P.; Butler, J.J.; Faiss, K.

    2008-01-01

    Information on vertical variations in hydraulic conductivity (K) can often shed much light on how a contaminant will move in the subsurface. The direct-push injection logger has been developed to rapidly obtain such information in shallow unconsolidated settings. This small-diameter tool consists of a short screen located just behind a drive point. The tool is advanced into the subsurface while water is injected through the screen to keep it clear. Upon reaching a depth at which information about K is desired, advancement ceases and the injection rate and pressure are measured on the land surface. The rate and pressure values are used in a ratio that serves as a proxy for K. A vertical profile of this ratio can be transformed into a K profile through regressions with K estimates determined using other techniques. The viability of the approach was assessed at an extensively studied field site in eastern Germany. The assessment demonstrated that this tool can rapidly identify zones that may serve as conduits for or barriers to contaminant movement. ?? 2007 The Author(s).

  3. A rapid method for hydraulic profiling in unconsolidated formations.

    PubMed

    Dietrich, Peter; Butler, James J; Faiss, Klaus

    2008-01-01

    Information on vertical variations in hydraulic conductivity (K) can often shed much light on how a contaminant will move in the subsurface. The direct-push injection logger has been developed to rapidly obtain such information in shallow unconsolidated settings. This small-diameter tool consists of a short screen located just behind a drive point. The tool is advanced into the subsurface while water is injected through the screen to keep it clear. Upon reaching a depth at which information about K is desired, advancement ceases and the injection rate and pressure are measured on the land surface. The rate and pressure values are used in a ratio that serves as a proxy for K. A vertical profile of this ratio can be transformed into a K profile through regressions with K estimates determined using other techniques. The viability of the approach was assessed at an extensively studied field site in eastern Germany. The assessment demonstrated that this tool can rapidly identify zones that may serve as conduits for or barriers to contaminant movement.

  4. Rapid Method for Sodium Hydroxide Fusion of Asphalt ...

    EPA Pesticide Factsheets

    Technical Brief--Addendum to Selected Analytical Methods (SAM) 2012 The method will be used for qualitative analysis of americium-241, plutonium-238, plutonium-239, radium-226, strontium-90, uranium-234, uranium-235 and uranium-238 in asphalt matrices samples.

  5. Operational Evaluation of the Rapid Viability PCR Method for ...

    EPA Pesticide Factsheets

    Journal Article This research work has a significant impact on the use of the RV-PCR method to analyze post-decontamination environmental samples during an anthrax event. The method has shown 98% agreement with the traditional culture based method. With such a success, this method, upon validation, will significantly increase the laboratory throughput/capacity to analyze a large number of anthrax event samples in a relatively short time.

  6. Method for rapid screening of pesticide mineralization in soil.

    PubMed

    Rasmussen, Jim; Jensen, Pia Haugaard; Holm, Peter E; Jacobsen, Ole Stig

    2004-05-01

    A method has been developed for the analysis of (14)CO(2) evolution from the mineralization of (14)C-labelled organic compounds in soil samples. The new method is less space demanding and substantially cuts down laborious manual work compared to the traditional incubation bottle method used. Furthermore, the use of scintillation cocktail is largely reduced with the new method. In the new method, (14)CO(2) is trapped in filter paper held in the lid of a 20 ml glass vial by surface tension. The trapping solution used is Ca(OH)(2), which fixates CO(2) in the filter paper and the analysis of trapped (14)CO(2) is done using the Cyclone trade mark Storage Phosphor system. The lids are placed in a 32 well holder and exposed to a phosphor screen prior to scanning in a Cyclone trade mark scanner. The new filter method has been tested and compared to results obtained using the traditional method. The results show good agreement but due to a smaller capacity for CO(2) with the filter method compared to the traditional method, the interval between sampling has to be shorter using the filter method when the CO(2) development is high. The detection limits for the filter method is higher compared to the traditional method. With the filter method, the level of radioactivity has to exceed 300 dpm before detection is possible, while the same limit for the traditional method is around 30 dpm. On the other hand, the gas trapping faster and the efficiency is higher with the filter method.

  7. Prokaryotic cDNA Subtraction: A Method to Rapidly Identify Functional Gene Biomarkers

    DTIC Science & Technology

    2008-10-01

    FINAL REPORT Prokaryotic cDNA Subtraction: A Method to Rapidly Identify Functional Gene Biomarkers SERDP Project ER-1563 OCTOBER 2008... Method to Rapidly Identify Functional Gene Biomarkers 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER...Studying Biological Treatment with MBT ...................................................................5 2.2 Methods for Obtaining Gene Sequences

  8. Rapid Method for Sodium Hydroxide Fusion of Concrete and ...

    EPA Pesticide Factsheets

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Americium-241, plutonium-238, plutonium-239, radium-226, strontium-90, uranium-234, uranium-235 and uranium-238 in concrete and brick samples Method Selected for: SAM lists this method for qualitative analysis of americium-241, plutonium-238, plutonium-239, radium-226, strontium-90, uranium-234, uranium-235 and uranium-238 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  9. Radiometric correction and equalization of satellite digital data

    NASA Technical Reports Server (NTRS)

    Algazi, V. R.; Ford, G. E.; Kazakoff, J. A.

    1979-01-01

    Satellite digital data from Landsat and NOAA satellites is often marred by striping or streaking errors due to variations in the response of the radiometric sensors. In this paper, we discuss the equalization of the digital data as a preprocessing step, prior to image enhancement or automatic classification. The methods described make use of statistics of the data itself to generate nonlinear or linear memory-less equalization algorithms. These algorithms, by contrast to multidimensional filtering, do not result in a loss of spatial resolution. Examples of applications to Landsat and NOAA-3 thermal infrared data are given and illustrated.

  10. Radiometric calibration of Landsat Thematic Mapper multispectral images

    USGS Publications Warehouse

    Chavez, P.S.

    1989-01-01

    A main problem encountered in radiometric calibration of satellite image data is correcting for atmospheric effects. Without this correction, an image digital number (DN) cannot be converted to a surface reflectance value. In this paper the accuracy of a calibration procedure, which includes a correction for atmospheric scattering, is tested. Two simple methods, a stand-alone and an in situ sky radiance measurement technique, were used to derive the HAZE DN values for each of the six reflectance Thematic Mapper (TM) bands. The DNs of two Landsat TM images of Phoenix, Arizona were converted to surface reflectances. -from Author

  11. Radiometric calibration to consider in quantitative clinical fluorescence imaging measurements

    NASA Astrophysics Data System (ADS)

    Litorja, M.; Urbas, A.; Zong, Y.

    2015-03-01

    The fluorescent light detected by a clinical imager is assumed to be proportional only to the amount of fluorescent substance present in the sample and the level of excitation. Unfortunately, there are many factors that can add or subtract to the light signal directly attributable to the desired fluorescence emission, especially with fluorescence from inside the body imaged remotely. The quantification of fluorescence emission is feasible by calibrating the imager using international system of units (SI)-traceable physical and material calibration artifacts such that the detector's digital numbers (DN) can be converted to radiometric units. Here we discuss three calibration methods for quantitative clinical fluorescence imaging systems.

  12. Rapid method for measuring rotenone in water at piscicidal concentrations

    USGS Publications Warehouse

    Dawson, V.K.; Harman, P.D.; Schultz, D.P.; Allen, J.L.

    1983-01-01

    A high-performance liquid chromatography (HPLC) procedure that is rapid, specific, and sensitive (limit of detection <0.005 mg/liter) was developed for monitoring application and degradation rates of rotenone. For analysis, a water sample is buffered to pH 5 and injected through a Sep Pak(R) C18 disposable cartridge. The cartridge adsorbs and retains the rotenone which then can be eluted quantitatively from the cartridge with a small volume of methanol. This step effectively concentrates the sample and provides sample cleanup. The methanol extract is analyzed directly by HPLC on an MCH 10 reverse-phase column; methanol: water (75:25, volume : volume) is the mobile phase and flow rate is 1.5 ml/minute. The rotenone is detected by ultraviolet spectrophotometry at a wavelength of 295 nm.

  13. Rapid Quantitative Method for Salmonella Detection in Polluted Waters

    PubMed Central

    Cheng, Chu Ming; Boyle, William C.; Goepfert, J. M.

    1971-01-01

    A procedure has been developed for the enumeration of salmonellae in polluted waters using several modifications of existing techniques. Confirmation of salmonellae is achieved within 48 hr. This procedure includes selective enrichment in m-Tetrathionate Broth (22 ± 1 hr), plating on Brilliant Green Sulfa Agar (20 ± 1 hr), and confirmation by flagellar (H) agglutination of the growth in a mannosecontaining medium (6 ± 1 hr). An incubation temperature of 41.5 C was used throughout this procedure. Dilution to extinction techniques (most probable number) were employed to enumerate salmonellae. Large sample volumes were concentrated through the use of membrane filters. This technique proved to be rapid and reliable for the enumeration of salmonellae in water, waste water, and waste-water sludges. PMID:4930275

  14. Electrical impedance measurements: rapid method for detecting and monitoring microorganisms.

    PubMed Central

    Cady, P; Dufour, S W; Shaw, J; Kraeger, S J

    1978-01-01

    A conceptually simple and east-to-use technique is described that uses continuous impedance measurements for automated monitoring of microbial growth and metabolism. The method has been applied to a wide range of microorganisms. Optical clarity is not required. The sensitivity and reproducibility of the method are demonstrated. The mechanism whereby microbial growth alters the impedance of the medium is discussed, as well as potential applications of the method to clinical microbiology. Images PMID:348718

  15. Rapid method for sampling metals for materials identification

    NASA Technical Reports Server (NTRS)

    Higgins, L. E.

    1971-01-01

    Nondamaging process similar to electrochemical machining is useful in obtaining metal samples from places inaccessible to conventional sampling methods or where methods would be hazardous or contaminating to specimens. Process applies to industries where metals or metal alloys play a vital role.

  16. Evaluating an alternative method for rapid urinary creatinine determination

    EPA Science Inventory

    Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...

  17. Evaluating an alternative method for rapid urinary creatinine determination

    EPA Science Inventory

    Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...

  18. A rapid cloning method employing orthogonal end protection.

    PubMed

    Jakobi, Arjen J; Huizinga, Eric G

    2012-01-01

    We describe a novel in vitro cloning strategy that combines standard tools in molecular biology with a basic protecting group concept to create a versatile framework for the rapid and seamless assembly of modular DNA building blocks into functional open reading frames. Analogous to chemical synthesis strategies, our assembly design yields idempotent composite synthons amenable to iterative and recursive split-and-pool reaction cycles. As an example, we illustrate the simplicity, versatility and efficiency of the approach by constructing an open reading frame composed of tandem arrays of a human fibronectin type III (FNIII) domain and the von Willebrand Factor A2 domain (VWFA2), as well as chimeric (FNIII)(n)-VWFA2-(FNIII)(n) constructs. Although we primarily designed this strategy to accelerate assembly of repetitive constructs for single-molecule force spectroscopy, we anticipate that this approach is equally applicable to the reconstitution and modification of complex modular sequences including structural and functional analysis of multi-domain proteins, synthetic biology or the modular construction of episomal vectors.

  19. A rapid wire-based sampling method for DNA profiling.

    PubMed

    Chen, Tong; Catcheside, David E A; Stephenson, Alice; Hefford, Chris; Kirkbride, K Paul; Burgoyne, Leigh A

    2012-03-01

    This paper reports the results of a commission to develop a field deployable rapid short tandem repeat (STR)-based DNA profiling system to enable discrimination between tissues derived from a small number of individuals. Speed was achieved by truncation of sample preparation and field deployability by use of an Agilent 2100 Bioanalyser(TM). Human blood and tissues were stabbed with heated stainless steel wire and the resulting sample dehydrated with isopropanol prior to direct addition to a PCR. Choice of a polymerase tolerant of tissue residues and cycles of amplification appropriate for the amount of template expected yielded useful profiles with a custom-designed quintuplex primer set suitable for use with the Bioanalyser(TM). Samples stored on wires remained amplifiable for months, allowing their transportation unrefrigerated from remote locations to a laboratory for analysis using AmpFlSTR(®) Profiler Plus(®) without further processing. The field system meets the requirements for discrimination of samples from small sets and retains access to full STR profiling when required.

  20. RAPID SEPARATION METHOD FOR 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.; Noyes, G.

    2010-07-26

    A new rapid method for the determination of {sup 237}Np and Pu isotopes in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for large soil samples. The new soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using this two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates are used to reduce analytical time.

  1. Corn syrup rapid method fermentables by HPLC. [High performance liquid chromatography

    SciTech Connect

    Pomes, A.F.

    1980-01-01

    Some breweries using corn syrup adjunct specify fermentable ranges determined by the ASBC rapid fermentation procedure. The present work was undertaken to develop a method of calculating rapid methods fermentables from syrup composition. Two equations were developed, by regression analyses of high-performance liquid chromatogrphic values for syrup composition and of laboratory data on rapid method fermentables. A third equation was derived from high-performance liquid chromatographic analyses of a series of syrup solutions before and after rapid fermentation. All equations resulted in good approximation of values obtained by laboratory fermentations.

  2. Corn syrup rapid method fermentables by HPLC. [High-performance liquid chromatography

    SciTech Connect

    Pomes, A.F.

    1980-01-01

    Some breweries using corn syrup adjunct specify fermentable ranges determined by the ASBC rapid fermentation procedure. The present work was undertaken to develop a method of calculating rapid methods fermentables from syrup composition. Two equations were developed, by regression analyses of high-performance liquid chromatographic values for syrup composition and of laboratory data on rapid method fermentables. A third equation was derived from high-performance liquid chromatographic analyses of a series of syrup solutions before and after rapid fermentation. All equations resulted in good approximation of values obtained by laboratory fermentations.

  3. Rapid Methods for the Detection of General Fecal Indicators

    EPA Science Inventory

    Specified that EPA should develop: appropriate and effective indicators for improving detection in a timely manner of pathogens in coastal waters appropriate, accurate, expeditious and cost-effective methods for the timely detection of pathogens in coastal waters

  4. Rapid Methods for the Detection of General Fecal Indicators

    EPA Science Inventory

    Specified that EPA should develop: appropriate and effective indicators for improving detection in a timely manner of pathogens in coastal waters appropriate, accurate, expeditious and cost-effective methods for the timely detection of pathogens in coastal waters

  5. The Candela and Photometric and Radiometric Measurements

    PubMed Central

    Parr, Albert C.

    2001-01-01

    The national measurement system for photometric and radiometric quantities is presently based upon techniques that make these quantities traceable to a high-accuracy cryogenic radiometer. The redefinition of the candela in 1979 provided the opportunity for national measurement laboratories to base their photometric measurements on optical detector technology rather than on the emission from high-temperature blackbody optical sources. The ensuing technical developments of the past 20 years, including the significant improvements in cryogenic radiometer performance, have provided the opportunity to place the fundamental maintenance of photometric quantities upon absolute detector based technology as was allowed by the 1979 redefinition. Additionally, the development of improved photodetectors has had a significant impact on the methodology in most of the radiometric measurement areas. This paper will review the status of the NIST implementation of the technical changes mandated by the 1979 redefinition of the candela and its effect upon the maintenance and dissemination of optical radiation measurements. PMID:27500020

  6. Infrared radiometric technique in temperature measurement

    NASA Technical Reports Server (NTRS)

    Glazer, S.; Madding, R.

    1988-01-01

    One class of commercially available imaging infrared radiometers using cooled detectors is sensitive to radiation over the 3 to 12 micron wavelength band. Spectral filters can tailor instrument sensitivity to specific regions where the target exhibits optimum radiance. The broadband spectral response coupled with real time two-dimensional imaging and emittance/background temperature corrections make the instruments useful for remote measurement of surface temperatures from -20 C to +1500 C. Commonly used radiometric techniques and assumptions are discussed, and performance specifications for a typical modern commercial instrument are presented. The potential usefulness of an imaging infrared radiometer in space laboratories is highlighted through examples of research, nondestructive evaluation, safety, and routine maintenance applications. Future improvements in instrument design and application of the radiometric technique are discussed.

  7. Radiometric calibration of digital cameras using Gaussian processes

    NASA Astrophysics Data System (ADS)

    Schall, Martin; Grunwald, Michael; Umlauf, Georg; Franz, Matthias O.

    2015-05-01

    Digital cameras are subject to physical, electronic and optic effects that result in errors and noise in the image. These effects include for example a temperature dependent dark current, read noise, optical vignetting or different sensitivities of individual pixels. The task of a radiometric calibration is to reduce these errors in the image and thus improve the quality of the overall application. In this work we present an algorithm for radiometric calibration based on Gaussian processes. Gaussian processes are a regression method widely used in machine learning that is particularly useful in our context. Then Gaussian process regression is used to learn a temperature and exposure time dependent mapping from observed gray-scale values to true light intensities for each pixel. Regression models based on the characteristics of single pixels suffer from excessively high runtime and thus are unsuitable for many practical applications. In contrast, a single regression model for an entire image with high spatial resolution leads to a low quality radiometric calibration, which also limits its practical use. The proposed algorithm is predicated on a partitioning of the pixels such that each pixel partition can be represented by one single regression model without quality loss. Partitioning is done by extracting features from the characteristic of each pixel and using them for lexicographic sorting. Splitting the sorted data into partitions with equal size yields the final partitions, each of which is represented by the partition centers. An individual Gaussian process regression and model selection is done for each partition. Calibration is performed by interpolating the gray-scale value of each pixel with the regression model of the respective partition. The experimental comparison of the proposed approach to classical flat field calibration shows a consistently higher reconstruction quality for the same overall number of calibration frames.

  8. Vicarious absolute radiometric calibration of GF-2 PMS2 sensor using permanent artificial targets in China

    NASA Astrophysics Data System (ADS)

    Liu, Yaokai; Li, Chuanrong; Ma, Lingling; Wang, Ning; Qian, Yonggang; Tang, Lingli

    2016-10-01

    GF-2, launched on August 19 2014, is one of the high-resolution land resource observing satellite of the China GF series satellites plan. The radiometric performance evaluation of the onboard optical pan and multispectral (PMS2) sensor of GF-2 satellite is very important for the further application of the data. And, the vicarious absolute radiometric calibration approach is one of the most useful way to monitor the radiometric performance of the onboard optical sensors. In this study, the traditional reflectance-based method is used to vicarious radiometrically calibrate the onboard PMS2 sensor of GF-2 satellite using three black, gray and white reflected permanent artificial targets located in the AOE Baotou site in China. Vicarious field calibration campaign were carried out in the AOE-Baotou calibration site on 22 April 2016. And, the absolute radiometric calibration coefficients were determined with in situ measured atmospheric parameters and surface reflectance of the permanent artificial calibration targets. The predicted TOA radiance of a selected desert area with our determined calibrated coefficients were compared with the official distributed calibration coefficients. Comparison results show a good consistent and the mean relative difference of the multispectral channels is less than 5%. Uncertainty analysis was also carried out and a total uncertainty with 3.87% is determined of the TOA radiance.

  9. MASS SPECTROMETRY PROTEOMICS METHOD AS A RAPID SCREENING TOOL FOR BACTERIAL CONTAMINATION OF FOOD

    DTIC Science & Technology

    2017-06-01

    MASS SPECTROMETRY PROTEOMICS METHOD AS A RAPID SCREENING TOOL FOR BACTERIAL CONTAMINATION OF FOOD ECBC-TR...TITLE AND SUBTITLE Mass Spectrometry Proteomics Method as a Rapid Screening Tool for Bacterial Contamination of Food 5a. CONTRACT NUMBER 5b...2 2.1 Preparation of Bacterial Stocks

  10. Rapid Dye Decolorization Method for Screening Potential Wood Preservatives

    PubMed Central

    Borokhov, Olga; Rothenburger, Stephen

    2000-01-01

    We developed a new screening method for potential wood preservatives based on decolorization of the dye Remazol Brilliant Blue R by extracellular oxidative agents produced by wood decay fungi. Oxidative biodegradation of lignin yielded decolorized zones around and under fungal cultures on a dyed agar medium. Inhibitory effects were detected by direct observation and measurement of the decolorized zones. PMID:11097927

  11. [Methods for the rapid preparation of paraffin blocks].

    PubMed

    Shmurun, R I

    1992-01-01

    Two accelerated chloroform-paraffin processings of materials with the use of ultrasound (US) and microwave (MW) irradiation in the stove "Electronica" as well as a combined method with US- and MW-irradiation are proposed to shorten drastically the duration of the prehistologic processing.

  12. Rapid method for interconversion of binary and decimal numbers

    NASA Technical Reports Server (NTRS)

    Lim, R. S.

    1970-01-01

    Decoding tree consisting of 40-bit semiconductor read-only memories interconverts binary and decimal numbers 50 to 100 times faster than current methods. Decimal-to-binary conversion algorithm is based on a divided-by-2 iterative equation, binary-to-decimal conversion algorithm utilizes multiplied-by-2 iterative equation.

  13. Geometric and Radiometric Evaluation of Rasat Images

    NASA Astrophysics Data System (ADS)

    Cam, Ali; Topan, Hüseyin; Oruç, Murat; Özendi, Mustafa; Bayık, Çağlar

    2016-06-01

    RASAT, the second remote sensing satellite of Turkey, was designed and assembled, and also is being operated by TÜBİTAK Uzay (Space) Technologies Research Institute (Ankara). RASAT images in various levels are available free-of-charge via Gezgin portal for Turkish citizens. In this paper, the images in panchromatic (7.5 m GSD) and RGB (15 m GSD) bands in various levels were investigated with respect to its geometric and radiometric characteristics. The first geometric analysis is the estimation of the effective GSD as less than 1 pixel for radiometrically processed level (L1R) of both panchromatic and RGB images. Secondly, 2D georeferencing accuracy is estimated by various non-physical transformation models (similarity, 2D affine, polynomial, affine projection, projective, DLT and GCP based RFM) reaching sub-pixel accuracy using minimum 39 and maximum 52 GCPs. The radiometric characteristics are also investigated for 8 bits, estimating SNR between 21.8-42.2, and noise 0.0-3.5 for panchromatic and MS images for L1R when the sea is masked to obtain the results for land areas. The analysis show that RASAT images satisfies requirements for various applications. The research is carried out in Zonguldak test site which is mountainous and partly covered by dense forest and urban areas.

  14. Revised landsat-5 thematic mapper radiometric calibration

    USGS Publications Warehouse

    Chander, G.; Markham, B.L.; Barsi, J.A.

    2007-01-01

    Effective April 2, 2007, the radiometric calibration of Landsat-5 (L5) Thematic Mapper (TM) data that are processed and distributed by the U.S. Geological Survey (USGS) Center for Earth Resources Observation and Science (EROS) will be updated. The lifetime gain model that was implemented on May 5, 2003, for the reflective bands (1-5, 7) will be replaced by a new lifetime radiometric-calibration curve that is derived from the instrument's response to pseudoinvariant desert sites and from cross calibration with the Landsat-7 (L7) Enhanced TM Plus (ETM+). Although this calibration update applies to all archived and future L5 TM data, the principal improvements in the calibration are for the data acquired during the first eight years of the mission (1984-1991), where the changes in the instrument-gain values are as much as 15%. The radiometric scaling coefficients for bands 1 and 2 for approximately the first eight years of the mission have also been changed. Users will need to apply these new coefficients to convert the calibrated data product digital numbers to radiance. The scaling coefficients for the other bands have not changed.

  15. A rapid chemiluminescent method for quantitation of human DNA.

    PubMed Central

    Walsh, P S; Varlaro, J; Reynolds, R

    1992-01-01

    A sensitive and simple method for the quantitation of human DNA is described. This method is based on probe hybridization to a human alpha satellite locus, D17Z1. The biotinylated probe is hybridized to sample DNA immobilized on nylon membrane. The subsequent binding of streptavidin-horseradish peroxidase to the bound probe allows for chemiluminescent detection using a luminol-based reagent and X-ray film. Less than 150 pg of human DNA can easily be detected with a 15 minute exposure. The entire procedure can be performed in 1.5 hours. Microgram quantities of nonhuman DNA have been tested and the results indicate very high specificity for human DNA. The data on film can be scanned into a computer and a commercially available program can be used to create a standard curve where DNA quantity is plotted against the mean density of each slot blot signal. The methods described can also be applied to the very sensitive determination of quantity and quality (size) of DNA on Southern blots. The high sensitivity of this quantitation method requires the consumption of only a fraction of sample for analysis. Determination of DNA quantity is necessary for RFLP and many PCR-based tests where optimal results are obtained only with a relatively narrow range of DNA quantities. The specificity of this quantitation method for human DNA will be useful for the analysis of samples that may also contain bacterial or other non-human DNA, for example forensic evidence samples, ancient DNA samples, or clinical samples. Images PMID:1408822

  16. A rapid chemiluminescent method for quantitation of human DNA.

    PubMed

    Walsh, P S; Varlaro, J; Reynolds, R

    1992-10-11

    A sensitive and simple method for the quantitation of human DNA is described. This method is based on probe hybridization to a human alpha satellite locus, D17Z1. The biotinylated probe is hybridized to sample DNA immobilized on nylon membrane. The subsequent binding of streptavidin-horseradish peroxidase to the bound probe allows for chemiluminescent detection using a luminol-based reagent and X-ray film. Less than 150 pg of human DNA can easily be detected with a 15 minute exposure. The entire procedure can be performed in 1.5 hours. Microgram quantities of nonhuman DNA have been tested and the results indicate very high specificity for human DNA. The data on film can be scanned into a computer and a commercially available program can be used to create a standard curve where DNA quantity is plotted against the mean density of each slot blot signal. The methods described can also be applied to the very sensitive determination of quantity and quality (size) of DNA on Southern blots. The high sensitivity of this quantitation method requires the consumption of only a fraction of sample for analysis. Determination of DNA quantity is necessary for RFLP and many PCR-based tests where optimal results are obtained only with a relatively narrow range of DNA quantities. The specificity of this quantitation method for human DNA will be useful for the analysis of samples that may also contain bacterial or other non-human DNA, for example forensic evidence samples, ancient DNA samples, or clinical samples.

  17. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    PubMed Central

    Kashani, Alireza G.; Olsen, Michael J.; Parrish, Christopher E.; Wilson, Nicholas

    2015-01-01

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration. PMID:26561813

  18. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration.

    PubMed

    Kashani, Alireza G; Olsen, Michael J; Parrish, Christopher E; Wilson, Nicholas

    2015-11-06

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record "intensity", loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of "normalization", "correction", or "calibration" techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  19. A new rapid method of solar simulator calibration

    NASA Technical Reports Server (NTRS)

    Ross, B.

    1976-01-01

    A quick method for checking solar simulator spectra content is presented. The method is based upon a solar cell of extended spectral sensitivity and known absolute response, and a dichroic mirror with the reflection transmission transition close to the peak wavelength of the Thekaekara AMO distribution. It compromises the need for spectral discrimination with the ability to integrate wide spectral regions of the distribution which was considered important due to the spiky nature of the high pressure xenon lamp in common use. The results are expressed in terms of a single number, the blue/red ratio, which, combined with the total (unfiltered) output, provides a simple adequate characterization. Measurements were conducted at eleven major facilities across the country and a total of eighteen simulators were measured including five pulsed units.

  20. Rapid Mapping Method Based on Free Blocks of Surveys

    NASA Astrophysics Data System (ADS)

    Yu, Xianwen; Wang, Huiqing; Wang, Jinling

    2016-06-01

    While producing large-scale larger than 1:2000 maps in cities or towns, the obstruction from buildings leads to difficult and heavy tasks of measuring mapping control points. In order to avoid measuring the mapping control points and shorten the time of fieldwork, in this paper, a quick mapping method is proposed. This method adjusts many free blocks of surveys together, and transforms the points from all free blocks of surveys into the same coordinate system. The entire surveying area is divided into many free blocks, and connection points are set on the boundaries between free blocks. An independent coordinate system of every free block is established via completely free station technology, and the coordinates of the connection points, detail points and control points in every free block in the corresponding independent coordinate systems are obtained based on poly-directional open traverses. Error equations are established based on connection points, which are determined together to obtain the transformation parameters. All points are transformed from the independent coordinate systems to a transitional coordinate system via the transformation parameters. Several control points are then measured by GPS in a geodetic coordinate system. All the points can then be transformed from the transitional coordinate system to the geodetic coordinate system. In this paper, the implementation process and mathematical formulas of the new method are presented in detail, and the formula to estimate the precision of surveys is given. An example has demonstrated that the precision of using the new method could meet large-scale mapping needs.

  1. Improved Training Method for Rapid Rehabilitation of Amputees

    DTIC Science & Technology

    2012-03-01

    ready for use. Patient centered information is also collected several questionnaires. The Prosthesis Evaluation Questionnaire (PEQ) is used to...functional outcomes , and a subject-specific questionnaire to determine if the training method is effective. Enrollment has begun. Our target is to deliver...a quantitatively derived, deployment-ready, advanced gait rehabilitation system that can improve functional outcomes and/or shorten the time

  2. Ambient methods and apparatus for rapid laser trace constituent analysis

    DOEpatents

    Snyder, Stuart C.; Partin, Judy K.; Grandy, Jon D.; Jeffery, Charles L.

    2002-01-01

    A method and apparatus are disclosed for measuring trace amounts of constituents in samples by using laser induced breakdown spectroscopy and laser induced fluorescence under ambient conditions. The laser induced fluorescence is performed at a selected wavelength corresponding to an absorption state of a selected trace constituent. The intensity value of the emission decay signal which is generated by the trace constituent is compared to calibrated emission intensity decay values to determine the amount of trace constituent present.

  3. Rapid column heating method for subcritical water chromatography.

    PubMed

    Fogwill, Michael O; Thurbide, Kevin B

    2007-01-19

    A novel resistive heating method is presented for subcritical water chromatography (SWC) that provides higher column heating rates than those conventionally obtained from temperature-programmed gas chromatography (GC) convection ovens. Since the polarity of water reduces dramatically with increasing temperature, SWC employs column heating to achieve gradient elution. As such, the rate at which the mobile phase is heated directly impacts the magnitude of such gradients applied in SWC. Data from the current study demonstrate that the maximum column heating rate attainable in a typical SWC apparatus (i.e. using a GC convection oven) is around 10 degrees C/min, even at instrument oven settings of over three times this value. Conversely, by wrapping the separation column with ceramic insulation and a resistively heated wire, the column heating rates are increased five-fold. As a result, elution times can be greatly decreased in SWC employing gradients. Separations of standard alcohol test mixtures demonstrate that the retention time of the latest eluting component decreases by 35 to 50% using the prototype method. Additionally, solute retention times in this mode deviate by less than 1% RSD over several trials, which compares very well to those obtained using a conventional GC convection oven. Results suggest that the developed method can be a useful alternative heating technique in SWC.

  4. A taxonomy of rapid reviews links report types and methods to specific decision-making contexts.

    PubMed

    Hartling, Lisa; Guise, Jeanne-Marie; Kato, Elisabeth; Anderson, Johanna; Belinson, Suzanne; Berliner, Elise; Dryden, Donna M; Featherstone, Robin; Mitchell, Matthew D; Motu'apuaka, Makalapua; Noorani, Hussein; Paynter, Robin; Robinson, Karen A; Schoelles, Karen; Umscheid, Craig A; Whitlock, Evelyn

    2015-12-01

    Describe characteristics of rapid reviews and examine the impact of methodological variations on their reliability and validity. We conducted a literature review and interviews with organizations that produce rapid reviews or related products to identify methods, guidance, empiric evidence, and current practices. We identified 36 rapid products from 20 organizations (production time, 5 minutes to 8 months). Methods differed from systematic reviews at all stages. As time frames increased, methods became more rigorous; however, restrictions on database searching, inclusion criteria, data extracted, and independent dual review remained. We categorized rapid products based on extent of synthesis. "Inventories" list what evidence is available. "Rapid responses" present best available evidence with no formal synthesis. "Rapid reviews" synthesize the quality of and findings from the evidence. "Automated approaches" generate meta-analyses in response to user-defined queries. Rapid products rely on a close relationship with end users and support specific decisions in an identified time frame. Limited empiric evidence exists comparing rapid and systematic reviews. Rapid products have tremendous methodological variation; categorization based on time frame or type of synthesis reveals patterns. The similarity across rapid products lies in the close relationship with the end user to meet time-sensitive decision-making needs. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Radiometric Characterization of Hyperspectral Imagers using Multispectral Sensors

    NASA Technical Reports Server (NTRS)

    McCorkel, Joel; Kurt, Thome; Leisso, Nathan; Anderson, Nikolaus; Czapla-Myers, Jeff

    2009-01-01

    The Remote Sensing Group (RSG) at the University of Arizona has a long history of using ground-based test sites for the calibration of airborne and satellite based sensors. Often, ground-truth measurements at these test sites are not always successful due to weather and funding availability. Therefore, RSG has also automated ground instrument approaches and cross-calibration methods to verify the radiometric calibration of a sensor. The goal in the cross-calibration method is to transfer the calibration of a well-known sensor to that of a different sensor, This work studies the feasibility of determining the radiometric calibration of a hyperspectral imager using multispectral a imagery. The work relies on the Moderate Resolution Imaging Spectroradiometer (M0DIS) as a reference for the hyperspectral sensor Hyperion. Test sites used for comparisons are Railroad Valley in Nevada and a portion of the Libyan Desert in North Africa. Hyperion bands are compared to MODIS by band averaging Hyperion's high spectral resolution data with the relative spectral response of M0DlS. The results compare cross-calibration scenarios that differ in image acquisition coincidence, test site used for the calibration, and reference sensor. Cross-calibration results are presented that show agreement between the use of coincident and non-coincident image pairs within 2% in most brands as well as similar agreement between results that employ the different MODIS sensors as a reference.

  6. Systems and methods for rapid processing and storage of data

    DOEpatents

    Stalzer, Mark A.

    2017-01-24

    Systems and methods of building massively parallel computing systems using low power computing complexes in accordance with embodiments of the invention are disclosed. A massively parallel computing system in accordance with one embodiment of the invention includes at least one Solid State Blade configured to communicate via a high performance network fabric. In addition, each Solid State Blade includes a processor configured to communicate with a plurality of low power computing complexes interconnected by a router, and each low power computing complex includes at least one general processing core, an accelerator, an I/O interface, and cache memory and is configured to communicate with non-volatile solid state memory.

  7. Detecting payload performance based on relative radiometric characteristic: case of the optical sensors

    NASA Astrophysics Data System (ADS)

    Han, Jie; Li, Shengyang; Zhang, Tao; Qin, Bangyong

    2016-10-01

    In this paper, we propose a novel algorithm for accurately estimating the degree of radiometric non-uniformity in remote sensing images. The algorithm was tested on high-quality images and heavily striping images, and quantitative analyses were conducted to evaluate the performance for each band by measuring the radiometric non-uniformity of the images. The results demonstrated that the proposed algorithm exhibits high accuracy and stability compared with traditional algorithms. The radiometric performance of TianGong-1 short-wave infrared images was calculated using this new method, and it was highly correlated with the solar angle, pitch angle and refrigerator thermal according to the Apriori algorithm. Based on these results, we have proposed a strategy for restricting increases in striping.

  8. Radiometric Calibration of Mars HiRISE High Resolution Imagery Based on Fpga

    NASA Astrophysics Data System (ADS)

    Hou, Yifan; Geng, Xun; Xing, Shuai; Tang, Yonghe; Xu, Qing

    2016-06-01

    Due to the large data amount of HiRISE imagery, traditional radiometric calibration method is not able to meet the fast processing requirements. To solve this problem, a radiometric calibration system of HiRISE imagery based on field program gate array (FPGA) is designed. The montage gap between two channels caused by gray inconsistency is removed through histogram matching. The calibration system is composed of FPGA and DSP, which makes full use of the parallel processing ability of FPGA and fast computation as well as flexible control characteristic of DSP. Experimental results show that the designed system consumes less hardware resources and the real-time processing ability of radiometric calibration of HiRISE imagery is improved.

  9. Absolute Radiometric Calibration of ALS Intensity Data: Effects on Accuracy and Target Classification

    PubMed Central

    Kaasalainen, Sanna; Pyysalo, Ulla; Krooks, Anssi; Vain, Ants; Kukko, Antero; Hyyppä, Juha; Kaasalainen, Mikko

    2011-01-01

    Radiometric calibration of airborne laser scanning (ALS) intensity data aims at retrieving a value related to the target scattering properties, which is independent on the instrument or flight parameters. The aim of a calibration procedure is also to be able to compare results from different flights and instruments, but practical applications are sparsely available, and the performance of calibration methods for this purpose needs to be further assessed. We have studied the radiometric calibration with data from three separate flights and two different instruments using external calibration targets. We find that the intensity data from different flights and instruments can be compared to each other only after a radiometric calibration process using separate calibration targets carefully selected for each flight. The calibration is also necessary for target classification purposes, such as separating vegetation from sand using intensity data from different flights. The classification results are meaningful only for calibrated intensity data. PMID:22346660

  10. Artifact correction and absolute radiometric calibration techniques employed in the Landsat 7 image assessment system

    USGS Publications Warehouse

    Boncyk, Wayne C.; Markham, Brian L.; Barker, John L.; Helder, Dennis

    1996-01-01

    The Landsat-7 Image Assessment System (IAS), part of the Landsat-7 Ground System, will calibrate and evaluate the radiometric and geometric performance of the Enhanced Thematic Mapper Plus (ETM +) instrument. The IAS incorporates new instrument radiometric artifact correction and absolute radiometric calibration techniques which overcome some limitations to calibration accuracy inherent in historical calibration methods. Knowledge of ETM + instrument characteristics gleaned from analysis of archival Thematic Mapper in-flight data and from ETM + prelaunch tests allow the determination and quantification of the sources of instrument artifacts. This a priori knowledge will be utilized in IAS algorithms designed to minimize the effects of the noise sources before calibration, in both ETM + image and calibration data.

  11. A multiplex PCR method for rapid identification of Brachionus rotifers.

    PubMed

    Vasileiadou, Kalliopi; Papakostas, Spiros; Triantafyllidis, Alexander; Kappas, Ilias; Abatzopoulos, Theodore J

    2009-01-01

    Cryptic species are increasingly being recognized in many organisms. In Brachionus rotifers, many morphologically similar yet genetically distinct species/biotypes have been described. A number of Brachionus cryptic species have been recognized among hatchery strains. In this study, we present a simple, one-step genetic method to detect the presence of those Brachionus sp. rotifers that have been found in hatcheries. With the proposed technique, each of the B. plicatilis sensu stricto, B. ibericus, Brachionus sp. Nevada, Brachionus sp. Austria, Brachionus sp. Manjavacas, and Brachionus sp. Cayman species and/or biotypes can be identified with polymerase chain reaction (PCR) analysis. Based on 233 cytochrome c oxidase subunit I sequences, we reviewed all the available cryptic Brachionus sp. genetic polymorphisms, and we designed six nested primers. With these primers, a specific amplicon of distinct size is produced for every one of the involved species/biotypes. Two highly sensitive protocols were developed for using the primers. Many of the primers can be combined in the same PCR. The proposed method has been found to be an effective and practical tool to investigate the presence of the above six cryptic species/biotypes in both individual and communal (bulk) rotifer deoxyribonucleic acid extractions from hatcheries. With this technique, hatchery managers could easily determine their rotifer composition at the level of cryptic species and monitor their cultures more efficiently.

  12. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid

  13. Radiometric-microbiologic assay of niacin using Kloeckera brevis: analysis of human blood and food

    SciTech Connect

    Guilarte, T.R.; Pravlik, K.

    1983-12-01

    Kloeckera brevis, a yeast, was used as the test organism for the development of a radiometric-microbiologic (RMA) assay for niacin. The assay was determined to be sensitive to the 2 ng niacin per vial level and specific for the biologically active forms of this vitamin. The method was shown to be simple, accurate, and precise in the analysis of niacin in human blood and food. The application of the radiometric technique eliminates some of the problems encountered with conventional turbidimetric-microbiologic assay.

  14. Rapid new methods for paint collection and lead extraction.

    PubMed

    Gutknecht, William F; Harper, Sharon L; Winstead, Wayne; Sorrell, Kristen; Binstock, David A; Salmons, Cynthia A; Haas, Curtis; McCombs, Michelle; Studabaker, William; Wall, Constance V; Moore, Curtis

    2009-01-01

    Chronic exposure of children to lead can result in permanent physiological impairment. In adults, it can cause irritability, poor muscle coordination, and nerve damage to the sense organs and nerves controlling the body. Surfaces coated with lead-containing paints are potential sources of exposure to lead. In April 2008, the U.S. Environmental Protection Agency (EPA) finalized new requirements that would reduce exposure to lead hazards created by renovation, repair, and painting activities, which disturb lead-based paint. On-site, inexpensive identification of lead-based paint is required. Two steps have been taken to meet this challenge. First, this paper presents a new, highly efficient method for paint collection that is based on the use of a modified wood drill bit. Second, this paper presents a novel, one-step approach for quantitatively grinding and extracting lead from paint samples for subsequent lead determination. This latter method is based on the use of a high-revolutions per minute rotor with stator to break up the paint into approximately 50 micron-size particles. Nitric acid (25%, v/v) is used to extract the lead in <3 minutes. Recoveries are consistently >95% for real-world paints, National Institute of Standards and Technology's standard reference materials, and audit samples from the American Industrial Hygiene Association's Environmental Lead Proficiency Analytical Testing Program. This quantitative extraction procedure, when paired with quantitative paint sample collection and lead determination, may enable the development of a lead paint test kit that will meet the specifications of the final EPA rule.

  15. NASA IKONOS Multispectral Radiometric Calibration and 3-Year Temporal Stability Assessment

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Carver, David; Holekamp, Kara; Ryan, Robert; Zanoni, Vicki; Thome, Kurtis; Schiller, Stephen; Aaran, David

    2003-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other system. In addition, the user community has little or no insight into the design and operation of commercial sensors or into the methods involved in generating commercial products. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) Directorate established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA, SSC,ESA, the University of Arizona Remote Sensing Group, and South Dacota State University. Each group determined the absolute radiometric calibration coefficients of the Space Imaging IKONOS 4-band, 4 m multispectral product covering the visible through near-infrared spectral region. For a three year period beginning in 2000, each team employed some variant of a reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with IKONOS image acquisitions and radiative transfer calculations. Several study sites throughout the United States were employed that covered nearly the entire dynamic range of the IKONOS sensor. IKONOS at-sensor radiance values were compared to those estimated by each independent group to determine the IKONOS sensor's radiometric accuracy and stability. Over 10 individual vicariously determined at-sensor radiance estimates were used each year. When combined, these estimates provided a high-precision radiometric gain calibration coefficient. No significant calibration offset was observed. The results of this evaluation provide the scientific community with an independent assessment of the IKONOS sensor's absolute calibration and temporal stability over the 3

  16. Rapid and simple method of qPCR primer design.

    PubMed

    Thornton, Brenda; Basu, Chhandak

    2015-01-01

    Quantitative real-time polymerase chain reaction (qPCR) is a powerful tool for analysis and quantification of gene expression. It is advantageous compared to traditional gel-based method of PCR, as gene expression can be visualized "real-time" using a computer. In qPCR, a reporter dye system is used which intercalates with DNA's region of interest and detects DNA amplification. Some of the popular reporter systems used in qPCR are the following: Molecular Beacon(®), SYBR Green(®), and Taqman(®). However, success of qPCR depends on the optimal primers used. Some of the considerations for primer design are the following: GC content, primer self-dimer, or secondary structure formation. Freely available software could be used for ideal qPCR primer design. Here we have shown how to use some freely available web-based software programs (such as Primerquest(®), Unafold(®), and Beacon designer(®)) to design qPCR primers.

  17. Rapid microbiochemical method for presumptive identification of gastroenteritis-associated members of the family Enterobacteriaceae.

    PubMed

    Yong, D C; Thompson, J S; Prytula, A

    1985-06-01

    A method for rapid screening of isolates of pathogenic members of the family Enterobacteriaceae is described. Flow charts are used in conjunction with triple sugar iron agar, o-nitrophenyl-beta-D-galactopyranoside-phenylalanine-motility sulfate screening media, oxidase test, and six rapid biochemical tests, namely, lysine decarboxylase, urease, indole, esculin hydrolysis, malonate, and xylose. This scheme is used to provide an inexpensive but rapid presumptive identification of Salmonella, Shigella, Edwardsiella, Aeromonas, Plesiomonas, Vibrio, and Yersinia isolates from stool cultures.

  18. High throughput microfluidic rapid and low cost prototyping packaging methods.

    PubMed

    Miled, Amine; Sawan, Mohamad

    2013-12-23

    In this work, 3 different packaging and assembly techniques are presented. They can be classified into two categories: one-time use and reusable packaging techniques. The one-time use packaging technique employs UV-based and temperature curing epoxies to connect microtubes to access holes, wire-bonding for integrated circuit connections, and silver epoxy for electrical connections. This method is based on a robust assembly technique that can support relatively high pressure close to 1 psi and does not need any support to strengthen the microfluidic architecture. Reusable packaging techniques consist of PDMS-based microtube interconnectors and anisotropic adhesive films for electrical connections. These devices are more sensitive and fragile. Consequently, Plexiglas support is added to the microfluidic structure to improve the electrical contact when anisotropic adhesive films are used, and also to strengthen the microfluidic architecture. In addition, a micromanipulator is needed to maintain tubes while using a thin PDMS layer to connect them to the access holes. Different PDMS layer thicknesses, ranging from 0.45-3 mm, are tested to compare the best adherence versus injection rates. Applied injection rates are varied from 50-300 μl/hr for 0.45-3 mm PDMS layers, respectively. These techniques are mainly applicable for low-pressure applications. However, they can be extended for high-pressure ones through plasma-oxygen process to permanently seal the PDMS to glass substrates. The main advantage of this technique, besides the fact that it is reusable, consists of keeping the device observable when the microchannel length is very short (in the range of 3 mm or lower).

  19. Radiometric calibration for MWIR cameras

    NASA Astrophysics Data System (ADS)

    Yang, Hyunjin; Chun, Joohwan; Seo, Doo Chun; Yang, Jiyeon

    2012-06-01

    Korean Multi-purpose Satellite-3A (KOMPSAT-3A), which weighing about 1,000 kg is scheduled to be launched in 2013 and will be located at a sun-synchronous orbit (SSO) of 530 km in altitude. This is Korea's rst satellite to orbit with a mid-wave infrared (MWIR) image sensor, which is currently being developed at Korea Aerospace Research Institute (KARI). The missions envisioned include forest re surveillance, measurement of the ocean surface temperature, national defense and crop harvest estimate. In this paper, we shall explain the MWIR scene generation software and atmospheric compensation techniques for the infrared (IR) camera that we are currently developing. The MWIR scene generation software we have developed taking into account sky thermal emission, path emission, target emission, sky solar scattering and ground re ection based on MODTRAN data. Here, this software will be used for generating the radiation image in the satellite camera which requires an atmospheric compensation algorithm and the validation of the accuracy of the temperature which is obtained in our result. Image visibility restoration algorithm is a method for removing the eect of atmosphere between the camera and an object. This algorithm works between the satellite and the Earth, to predict object temperature noised with the Earth's atmosphere and solar radiation. Commonly, to compensate for the atmospheric eect, some softwares like MODTRAN is used for modeling the atmosphere. Our algorithm doesn't require an additional software to obtain the surface temperature. However, it needs to adjust visibility restoration parameters and the precision of the result still should be studied.

  20. Relative radiometric calibration of LANDSAT TM reflective bands

    NASA Technical Reports Server (NTRS)

    Barker, J. L.

    1984-01-01

    Raw thematic mapper (TM) calibration data from pre-launch tests and in-orbit acquisitions from LANDSAT 4 and 5 satellites are analyzed to assess the radiometric characteristics of the TM sensor. A software program called TM radiometric and algorithmic performance program (TRAPP) was used for the majority of analyses. Radiometric uncertainty in the final TM image originates from: (1) scene variability (solar irradiance and atmospheric scattering); (2) optical and electrical variability of the sensor; and (3) variability introduced during image processing.

  1. The RAPID technique: a new method for evaluating downstream effects of forest practices on riparian zones.

    Treesearch

    G. Grant

    1988-01-01

    The RAPID (riparian aerial photographic inventory of disturbance) technique is a method for using measurements made on aerial photographs of patterns of riparian canopy disturbance to evaluate changes in channel conditions through time and to link such changes with their possible upstream causes. The RAPID technique provides resource specialists and managers with a...

  2. The importance and attainment of accurate absolute radiometric calibration

    NASA Technical Reports Server (NTRS)

    Slater, P. N.

    1984-01-01

    The importance of accurate absolute radiometric calibration is discussed by reference to the needs of those wishing to validate or use models describing the interaction of electromagnetic radiation with the atmosphere and earth surface features. The in-flight calibration methods used for the Landsat Thematic Mapper (TM) and the Systeme Probatoire d'Observation de la Terre, Haute Resolution visible (SPOT/HRV) systems are described and their limitations discussed. The questionable stability of in-flight absolute calibration methods suggests the use of a radiative transfer program to predict the apparent radiance, at the entrance pupil of the sensor, of a ground site of measured reflectance imaged through a well characterized atmosphere. The uncertainties of such a method are discussed.

  3. Radiometric instrumentation and measurements guide for photovoltaic performance testing

    SciTech Connect

    Myers, D.

    1997-04-01

    The Photovoltaic Module and Systems Performance and Engineering Project at the National Renewable Energy Laboratory performs indoor and outdoor standardization, testing, and monitoring of the performance of a wide range of photovoltaic (PV) energy conversion devices and systems. The PV Radiometric Measurements and Evaluation Team (PVSRME) within that project is responsible for measurement and characterization of natural and artificial optical radiation which stimulates the PV effect. The PV manufacturing and research and development community often approaches project members for technical information and guidance. A great area of interest is radiometric instrumentation, measurement techniques, and data analysis applied to understanding and improving PV cell, module, and system performance. At the Photovoltaic Radiometric Measurements Workshop conducted by the PVSRME team in July 1995, the need to communicate knowledge of solar and optical radiometric measurements and instrumentation, gained as a result of NREL`s long-term experiences, was identified as an activity that would promote improved measurement processes and measurement quality in the PV research and manufacturing community. The purpose of this document is to address the practical and engineering need to understand optical and solar radiometric instrument performance, selection, calibration, installation, and maintenance applicable to indoor and outdoor radiometric measurements for PV calibration, performance, and testing applications. An introductory section addresses radiometric concepts and definitions. Next, concepts essential to spectral radiometric measurements are discussed. Broadband radiometric instrumentation and measurement concepts are then discussed. Each type of measurement serves as an important component of the PV cell, module, and system performance measurement and characterization process.

  4. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors

    PubMed Central

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-01

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors’ radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors’ application, and as such will promote the development of Chinese satellite data. PMID:28117745

  5. Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors.

    PubMed

    Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo

    2017-01-22

    The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors' radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors' application, and as such will promote the development of Chinese satellite data.

  6. Aerial radiometric and magnetic reconnaissance survey of south-central Colorado Trinidad Quadrangle

    SciTech Connect

    Not Available

    1980-01-01

    The results of a high-sensitivity, aerial, gamma-ray spectrometer and magnetometer survey of the Trinidad Quadrangle, Colorado, are presented. Instrumentation and methods are described in Volume 1 of this final report. Statistical and geological analysis of radiometric data revealed 51 uranium anomalies worthy of field-checking as possible prospects.

  7. Rapid methods for the detection of foodborne bacterial pathogens: principles, applications, advantages and limitations

    PubMed Central

    Law, Jodi Woan-Fei; Ab Mutalib, Nurul-Syakima; Chan, Kok-Gan; Lee, Learn-Han

    2015-01-01

    The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR), multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP) and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases. PMID:25628612

  8. Rapid methods for the detection of foodborne bacterial pathogens: principles, applications, advantages and limitations.

    PubMed

    Law, Jodi Woan-Fei; Ab Mutalib, Nurul-Syakima; Chan, Kok-Gan; Lee, Learn-Han

    2014-01-01

    The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR), multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP) and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases.

  9. Systematic biases in radiometric diameter determinations

    NASA Technical Reports Server (NTRS)

    Spencer, John R.; Lebofsky, Larry A.; Sykes, Mark V.

    1989-01-01

    Radiometric diameter determinations are presently shown to often be significantly affected by the effect of rotation. This thermal effect of rotation depends not only on the object's thermal inertia, rotation rate, and pole orientation, but also on its temperature, since colder objects having constant rotation rate and thermal inertia will radiate less of their heat on the diurnal than on the nocturnal hemisphere. A disk-integrated beaming parameter of 0.72 is determined for the moon, and used to correct empirically for the roughness effects in thermophysical models; the standard thermal model is found to systematically underestimate cold object diameters, while overstating their albedos.

  10. A Nucleic Acid Probe and Method for the Rapid Detection of Typhoid Fever Bacteria.

    DTIC Science & Technology

    This invention relates to a nucleic acid probe and method for the rapid detection of typhoid fever bacteria by use of a nucleic acid hybridization...a nucleic acid hybridization reaction with a clinical specimen containing typhoid fever bacteria.

  11. Framework for the Data-Driven Geographical Expansion of Rapid Ecological Assessment Methods

    DTIC Science & Technology

    2014-12-01

    G.A. de Leo, I. Ferrari. 2004. A critical review of representative wetland rapid assessment methods in North America. Aquatic Conservation: Marine... Wetlands Regulatory Assistance Program ERDC TN-WRAP-14-1 December 2014 Approved for public release; distribution is unlimited. Framework for the...The current study outlines guidance for expanding the geographic extent of existing wetland and stream rapid ecological assessment methods beyond

  12. Methods of Rapid Microbiological Assay and Their Application to Pharmaceutical and Medical Device Fabrication.

    PubMed

    Shintani, Hideharu

    2016-01-01

     There are several rapid microbiological methods becoming available that have useful applications in pharmaceutical and medical devices. They are ATP bioluminescence, fluorescent labeling, electrical resistance, and nucleic acid probes. In choosing to employ rapid methods, the microbiologist should examine their prospective performances against the specific requirements for that sector. Some methods may require expensive equipment and offer full automation, and others represent only a small investment. The regulatory view of these methods is changing and they still officially have not been approved in medical and pharmaceutical area, but it will still be up to the microbiologist to demonstrate that the method chosen is fit for the purpose intended.

  13. New Sentinel-2 radiometric validation approaches (SEOM program)

    NASA Astrophysics Data System (ADS)

    Bruniquel, Véronique; Lamquin, Nicolas; Ferron, Stéphane; Govaerts, Yves; Woolliams, Emma; Dilo, Arta; Gascon, Ferran

    2016-04-01

    SEOM is an ESA program element whose one of the objectives aims at launching state-of-the-art studies for the scientific exploitation of operational missions. In the frame of this program, ESA awarded ACRI-ST and its partners Rayference and National Physical Laboratory (NPL) early 2016 for a R&D study on the development and intercomparison of algorithms for validating the Sentinel-2 radiometric L1 data products beyond the baseline algorithms used operationally in the frame of the S2 Mission Performance Centre. In this context, several algorithms have been proposed and are currently in development: The first one is based on the exploitation of Deep Convective Cloud (DCC) observations over ocean. This method allows an inter-band radiometry validation from the blue to the NIR (typically from B1 to B8a) from a reference band already validated for example with the well-known Rayleigh method. Due to their physical properties, DCCs appear from the remote sensing point of view to have bright and cold tops and they can be used as invariant targets to monitor the radiometric response degradation of reflective solar bands. The DCC approach is statistical i.e. the method shall be applied on a large number of measurements to derive reliable statistics and decrease the impact of the perturbing contributors. The second radiometric validation method is based on the exploitation of matchups combining both concomitant in-situ measurements and Sentinel-2 observations. The in-situ measurements which are used here correspond to measurements acquired in the frame of the RadCalNet networks. The validation is performed for the Sentinel-2 bands similar to the bands of the instruments equipping the validation site. The measurements from the Cimel CE 318 12-filters BRDF Sun Photometer installed recently in the Gobabeb site near the Namib desert are used for this method. A comprehensive verification of the calibration requires an analysis of MSI radiances over the full dynamic range

  14. Radiometric Cross-Calibration of the HJ-1B IRS in the Thermal Infrared Spectral Band

    NASA Astrophysics Data System (ADS)

    Sun, K.

    2012-12-01

    The natural calamities occur continually, environment pollution and destruction in a severe position on the earth presently, which restricts societal and economic development. The satellite remote sensing technology has an important effect on improving surveillance ability of environment pollution and natural calamities. The radiometric calibration is precondition of quantitative remote sensing; which accuracy decides quality of the retrieval parameters. Since the China Environment Satellite (HJ-1A/B) has been launched successfully on September 6th, 2008, it has made an important role in the economic development of China. The satellite has four infrared bands; and one of it is thermal infrared. With application fields of quantitative remote sensing in china, finding appropriate calibration method becomes more and more important. Many kinds of independent methods can be used to do the absolute radiometric calibration. In this paper, according to the characteristic of thermal infrared channel of HJ-1B thermal infrared multi-spectral camera, the thermal infrared spectral band of HJ-1B IRS was calibrated using cross-calibration methods based on MODIS data. Firstly, the corresponding bands of the two sensors were obtained. Secondly, the MONDTRAN was run to analyze the influences of different spectral response, satellite view zenith angle, atmosphere condition and temperature on the match factor. In the end, their band match factor was calculated in different temperature, considering the dissimilar band response of the match bands. Seven images of Lake Qinghai in different time were chosen as the calibration data. On the basis of radiance of MODIS and match factor, the IRS radiance was calculated. And then the calibration coefficients were obtained by linearly regressing the radiance and the DN value. We compared the result of this cross-calibration with that of the onboard blackbody calibration, which consistency was good.The maximum difference of brightness temperature

  15. Photovoltaic radiometric measurements workshop introduction and overview

    SciTech Connect

    Myers, D.R.

    1995-09-01

    The National Renewable Energy Laboratory supports the U.S. Department of Energy`s photovoltaic (PV) program through research in basic and engineering sciences related to improving the performance and commercial viability of PV energy conversion as an alternative energy source. Since 1975, much progress and technological evolution has taken place, chronicled in part by periodic scientific and engineering conferences, program reviews, and workshops involving manufacturers, universities, and private and government research laboratories. The growth of the PV program resulted in more specialized and topical workshops sponsored in part by the NREL Photovoltaic Module and Systems Performance and Engineering Project to address specific program issues. Solar and optical radiometric measurements and data are crucial in quantifying PV research progress, available solar resources, and predicted and installed PV array performance. This workshop is an effort to focus on the state-of-the-art, needs, future research directions, and NREL action items for radiometric instrumentation, data, and research to maintain the momentum of progress toward the fundamental understanding of, improvement in, and sustainability of PV technology as an alternative energy source.

  16. Real-time adaptive radiometric compensation.

    PubMed

    Grundhöfer, Anselm; Bimber, Oliver

    2008-01-01

    Recent radiometric compensation techniques make it possible to project images onto colored and textured surfaces. This is realized with projector-camera systems by scanning the projection surface on a per-pixel basis. Using the captured information, a compensation image is calculated that neutralizes geometric distortions and color blending caused by the underlying surface. As a result, the brightness and the contrast of the input image is reduced compared to a conventional projection onto a white canvas. If the input image is not manipulated in its intensities, the compensation image can contain values that are outside the dynamic range of the projector. These will lead to clipping errors and to visible artifacts on the surface. In this article, we present an innovative algorithm that dynamically adjusts the content of the input images before radiometric compensation is carried out. This reduces the perceived visual artifacts while simultaneously preserving a maximum of luminance and contrast. The algorithm is implemented entirely on the GPU and is the first of its kind to run in real-time.

  17. The potential of the case-control method for rapid epidemiological assessment.

    PubMed

    Baltazar, J C

    1991-01-01

    Over the past few decades, the case-control method has been mostly applied to risk-factor studies of chronic diseases. Recently, among its new applications is the use of the method to study the health effect of improvements in sanitation and water supply. The methodological considerations, prospects and constraints of the method for rapid assessment are reviewed.

  18. Rapid identification of salmonella serotypes with stereo and hyperspectral microscope imaging Methods

    USDA-ARS?s Scientific Manuscript database

    The hyperspectral microscope imaging (HMI) method can reduce detection time within 8 hours including incubation process. The early and rapid detection with this method in conjunction with the high throughput capabilities makes HMI method a prime candidate for implementation for the food industry. Th...

  19. Rapid Identification of Salmonella Serotypes with Stereo and Hyperspectral Microscope Imaging Methods

    USDA-ARS?s Scientific Manuscript database

    The hyperspectral microscope imaging (HMI) method can reduce detection time within 8 hours including incubation process. The early and rapid detection with this method in conjunction with the high throughput capabilities makes HMI method a prime candidate for implementation for the food industry. Th...

  20. Field Evaluation of a Semiautomated Method for Rapid and Simple Analysis of Recreational Water Microbiological Quality

    PubMed Central

    Anglès d'Auriac, Marc B.; Roberts, Hildegarde; Shaw, Terri; Sirevåg, Reidun; Hermansen, Leonila Fajardo; Berg, James D.

    2000-01-01

    An early warning system using a rapid enzymatic semiautomated method suitable for fecal coliform detection in recreational waters within 8 h was developed further and evaluated in this study. This rapid method was compared to the standard method followed in the United Kingdom. We used 1,011 samples originating from 206 different locations in Wales. When we assessed the presence or absence of fecal coliforms, targeting very low levels of contamination, we obtained 83.9% agreement between the rapid method and the lauryl sulfate broth-membrane filtration technique, whereas direct confirmation of the samples processed by the rapid method showed 89.3% agreement. Environmental enzymatic background activity was found to be the main limiting factor for this method. Owing to a specific and integrated handling of the results by the software of the instrument, the percentage of false-positive results (a consequence of enzymatic background) was successfully limited to 2.9% by the direct confirmation evaluation. However, 7.8% false-negative results due to “late-growers” had to be accepted in order to produce results within a working day. At present, the method can be used in a more conservative way to assess the environmental threshold of 100 CFU of fecal coliforms per 100 ml in recreational waters. The implications of our findings with regard to the applicability of rapid enzymatic methods are discussed. PMID:11010890

  1. Understanding Satellite Characterization Knowledge Gained from Radiometric Data

    DTIC Science & Technology

    2011-09-01

    UNDERSTANDING SATELLITE CHARACTERIZATION KNOWLEDGE GAINED FROM RADIOMETRIC DATA Andrew Harms Princeton University Kris Hamada, Charles J. Wetterer...framework for determining satellite characterization knowledge, in the form of estimated parameter uncertainties, from radiometric observation type...uncer- tainties into satellite characterization parameter space. These parameters can include size, shape, orientation, material properties, etc., and

  2. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements

    DTIC Science & Technology

    2015-03-31

    Final March 2013 -- February 2015 Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements N00014-13-1-0352 Yue, Dick K.P... Dick K.P. and Yuming Liu 617-253-6823; 617-252-1647 1 Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements Dick K.P

  3. Best practices for radiometric modeling of imaging spectrometers

    NASA Astrophysics Data System (ADS)

    Zellinger, Lou; Silny, John F.

    2015-09-01

    This paper provides best practices for the radiometric performance modeling of imaging spectrometers. A set of standard terminology is proposed to use when modeling imaging spectrometers. The calculation of various radiometric sensitivity metrics and their contrast counterparts are outlined. Modeling approaches are described for both solar reflected and thermally emitted bands. Finally, this approach is applied to an example hyperspectral sensor.

  4. Validation of Landsat 7 ETM+ band 6 radiometric performance

    NASA Technical Reports Server (NTRS)

    Palluconi, Frank; Hook, Simon; Abtahi, Ali; Alley, Ron

    2005-01-01

    Since shortly after launch the radiometric performance of band 6 of the ETM+ instrument on Landsat 7 has been evaluated using vicarious calbiration techniques for both land and water targets. This evaluation indicates the radiometric performance of band 6 has been both highly stable and accurate.

  5. An international survey and modified Delphi approach revealed numerous rapid review methods.

    PubMed

    Tricco, Andrea C; Zarin, Wasifa; Antony, Jesmin; Hutton, Brian; Moher, David; Sherifali, Diana; Straus, Sharon E

    2016-02-01

    To solicit experiences with and perceptions of rapid reviews from stakeholders, including researchers, policy makers, industry, journal editors, and health care providers. An international survey of rapid review producers and modified Delphi. Forty rapid review producers responded on our survey (63% response rate). Eighty-eight rapid reviews with 31 different names were reported. Rapid review commissioning organizations were predominantly government (78%) and health care (58%) organizations. Several rapid review approaches were identified, including updating the literature search of previous reviews (92%); limiting the search strategy by date of publication (88%); and having only one reviewer screen (85%), abstract data (84%), and assess the quality of studies (86%). The modified Delphi included input from 113 stakeholders on the rapid review approaches from the survey. Approach 1 (search limited by date and language; study selection by one reviewer only, and data abstraction and quality appraisal conducted by one reviewer and one verifier) was ranked the most feasible (72%, 81/113 responses), with the lowest perceived risk of bias (12%, 12/103); it also ranked second in timeliness (37%, 38/102) and fifth in comprehensiveness (5%, 5/100). Rapid reviews have many names and approaches, and some methods might be more desirable than others. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Radiometric performance of the Viking Mars lander cameras

    NASA Technical Reports Server (NTRS)

    Huck, F. O.; Burcher, E. E.; Taylor, E. J.; Wall, S. D.

    1975-01-01

    The Viking lander cameras feature an array of 12 silicon photodiodes for electronic focus selection and multispectral imaging. Comparisons of absolute radiometric calibrations of the four cameras selected for the mission to Mars with performance predictions based on their design data revealed minor discrepancies. These discrepancies were caused primarily by the method used to calibrate the photosensor array and apparently also from light reflections internal to the array. The sensitivity and dynamic range of all camera channels are found to be sufficient for high quality pictures, providing that the commandable gains and offsets can be optimized for the scene radiance; otherwise, the quantization noise may be too high or the dynamic range too low for an adequate characterization of the scene.

  7. Active radiometric calorimeter for absolute calibration of radioactive sources

    SciTech Connect

    Stump, K.E.; DeWerd, L.A.; Rudman, D.A.; Schima, S.A.

    2005-03-01

    This report describes the design and initial noise floor measurements of a radiometric calorimeter designed to measure therapeutic medical radioactive sources. The instrument demonstrates a noise floor of approximately 2 nW. This low noise floor is achieved by using high temperature superconducting (HTS) transition edge sensor (TES) thermometers in a temperature-control feedback loop. This feedback loop will be used to provide absolute source calibrations based upon the electrical substitution method. Other unique features of the calorimeter are (a) its ability to change sources for calibration without disrupting the vacuum of the instrument, and (b) the ability to measure the emitted power of a source in addition to the total contained source power.

  8. [In-flight absolute radiometric calibration of UAV multispectral sensor].

    PubMed

    Chen, Wei; Yan, Lei; Gou, Zhi-Yang; Zhao, Hong-Ying; Liu, Da-Ping; Duan, Yi-Ni

    2012-12-01

    Based on the data of the scientific experiment in Urad Front Banner for UAV Remote Sensing Load Calibration Field project, with the help of 6 hyperspectral radiometric targets with good Lambertian property, the wide-view multispectral camera in UAV was calibrated adopting reflectance-based method. The result reveals that for green, red and infrared channel, whose images were successfully captured, the linear correlation coefficients between the DN and radiance are all larger than 99%. In final analysis, the comprehensive error is no more than 6%. The calibration results demonstrate that the hyperspectral targets equipped by the calibration field are well suitable for air-borne multispectral load in-flight calibration. The calibration result is reliable and could be used in the retrieval of geophysical parameters.

  9. Thematic mapper: detailed radiometric and geometric characteristics

    USGS Publications Warehouse

    Kieffer, Hugh

    1983-01-01

    Those radiometric characteristics of the Landsat 4 Thematic Mapper (TM) that can be established without absolute calibration of spectral data have been examined. Subscenes of radiometric all raw data (B-data) were examined on an individual detector basis: areas of uniform radiance were used to characterize subtle radiometric differences and noise problems. A variety of anomalies have been discovered with magnitude of a few digital levels or less: the only problem not addressable by ground processing is irregular width of the digital levels. Essentially all of this non-ideal performance is incorporated in the fully processed (P-type) images, but disguised by the geometric resampling procedure. The overall performance of the Thematic Mapper is a great improvement over previous Landsat scanners. The effective resolution in radiance is degraded by about a factor of two by irregular width of the digital levels. Several detectors have a change of gain with a period of several scans, the largest effect is about 4%. These detectors appear to switch between two response levels during scan direction reversal; there is no apparent periodicity to these changes. This can cause small apparent difference between forward and reverse scans for portions of an image. The high-frequency noise level of each detector was characterized by the standard deviation of the first derivative in the sample direction across a flat field. Coherent sinusoidal noise patterns were determined using one-dimensional Fourier transforms. A "stitching" pattern in Band 1 has a period of 13.8 samples with a peak-to-peak amplitude ranging from 1 to 5 DN. Noise with a period of 3.24 samples is pronounced for most detectors in band 1, to a lesser extent in bands 2, 3, and 4, and below background noise levels in bands 5, 6, and 7. The geometric fidelity of the GSFC film writer used for Thematic Mapper (TM) images was assessed by measurement with accuracy bette than three micrometers of a test grid. A set of 55

  10. Visible/infrared radiometric calibration station

    SciTech Connect

    Byrd, D.A.; Maier, W.B. II; Bender, S.C.; Holland, R.F.; Michaud, F.D.; Luettgen, A.L.; Christensen, R.W.; O`Brian, T.R.

    1994-07-01

    We have begun construction of a visible/infrared radiometric calibration station that will allow for absolute calibration of optical and IR remote sensing instruments with clear apertures less than 16 inches in diameter in a vacuum environment. The calibration station broadband sources will be calibrated at the National Institute of Standards and Technology (NIST) and allow for traceable absolute radiometric calibration to within {plus_minus}3% in the visible and near IR (0.4--2.5 {mu}m), and less than {plus_minus}1% in the infrared, up to 12 {mu}m. Capabilities for placing diffraction limited images or for sensor full-field flooding will exist. The facility will also include the calibration of polarization and spectral effects, spatial resolution, field of view performance, and wavefront characterization. The configuration of the vacuum calibration station consists of an off-axis 21 inch, f/3.2, parabolic collimator with a scanning fold flat in collimated space. The sources are placed, via mechanisms to be described, at the focal plane of the off-axis parabola. Vacuum system pressure will be in the 10{sup {minus}6} Torr range. The broadband white-light source is a custom design by LANL with guidance from Labsphere Inc. The continuous operating radiance of the integrating sphere will be from 0.0--0.006 W/cm{sup 2}/Sr/{mu}m (upper level quoted for {approximately}500 nm wavelength). The blackbody source is also custom designed at LANL with guidance from NIST. The blackbody temperature will be controllable between 250--350{degrees}K. Both of the above sources have 4.1 inch apertures with estimated radiometric instability at less than 1%. The designs of each of these units will be described. The monochromator and interferometer light sources are outside the vacuum, but all optical relay and beam shaping optics are enclosed within the vacuum calibration station. These sources are described, as well as the methodology for alignment and characterization.

  11. Assessment criteria and approaches for rapid detection methods to be used in the food industry.

    PubMed

    Wiedmann, Martin; Wang, Siyun; Post, Laurie; Nightingale, Kendra

    2014-04-01

    The number of commercially available kits and methods for rapid detection of foodborne pathogens continues to increase at a considerable pace, and the diversity of methods and assay formats is reaching a point where it is very difficult even for experts to weigh the advantages and disadvantages of different methods and to decide which methods to choose for a certain testing need. Although a number of documents outline quantitative criteria that can be used to evaluate different detection methods (e.g., exclusivity and inclusivity), a diversity of criteria is typically used by industry to select specific methods that are used for pathogen detection. This article is intended to provide an overall outline of criteria that the food industry can use to evaluate new rapid detection methods, with a specific focus on nucleic acid-based detection methods.

  12. High-throughput radiometric CYP2C19 inhibition assay using tritiated (S)-mephenytoin.

    PubMed

    Di Marco, Annalise; Cellucci, Antonella; Chaudhary, Ashok; Fonsi, Massimiliano; Laufer, Ralph

    2007-10-01

    A rapid and sensitive radiometric assay for assessing the potential of drugs to inhibit cytochrome P450 (P450) 2C19 in human liver microsomes is described. The new assay, which does not require high-performance liquid chromatography (HPLC) separation or mass spectrometric detection, is based on the release of tritium as tritiated water that occurs upon CYP2C19-mediated 4'-hydroxylation of (S)-mephenytoin labeled with tritium in the 4' position. Because this reaction is subject to an NIH shift, tritium was also introduced into the 3'- and 5'-positions of the tracer to enhance formation of a tritiated water product. Tritiated water was separated from the substrate using 96-well solid-phase extraction plates. The reaction is NADPH-dependent and sensitive to CYP2C19 inhibitors. IC(50) values for 15 diverse drugs differed less than 2.5-fold from those determined by quantification of the unlabeled 4'-hydroxy-(S)-mephenytoin product, using HPLC coupled to mass spectrometric detection. All of the steps of the new assay, namely incubation, product separation, and radioactivity counting, are performed in a 96-well format and can be automated. This assay represents a non-HPLC, high-throughput version of the classic (S)-mephenytoin 4'-hydroxylation assay, which is the most widely used method to assess the potential for CYP2C19 inhibition of new chemical entities.

  13. Method for the rapid synthesis of large quantities of metal oxide nanowires at low temperatures

    DOEpatents

    Sunkara, Mahendra Kumar [Louisville, KY; Vaddiraju, Sreeram [Mountain View, CA; Mozetic, Miran [Ljubljan, SI; Cvelbar, Uros [Idrija, SI

    2009-09-22

    A process for the rapid synthesis of metal oxide nanoparticles at low temperatures and methods which facilitate the fabrication of long metal oxide nanowires. The method is based on treatment of metals with oxygen plasma. Using oxygen plasma at low temperatures allows for rapid growth unlike other synthesis methods where nanomaterials take a long time to grow. Density of neutral oxygen atoms in plasma is a controlling factor for the yield of nanowires. The oxygen atom density window differs for different materials. By selecting the optimal oxygen atom density for various materials the yield can be maximized for nanowire synthesis of the metal.

  14. [A rapid method of eddy current compensation in magnetic resonance imaging systems].

    PubMed

    Liu, Zheng-min; Zhou, He-qin; Wu, Hai-cheng

    2005-11-01

    Imaging objects are spatially encoded by gradient magnetic fields in magnetic resonance imaging systems. The eddy current caused by rapid switches of gradient fields will result in artifacts in the images. A method of eddy current compensation based on pre-emphasis of gradient current is presented in this thesis. The compensation parameters are acquired rapidly utilizing Faraday's induction theorem and data fitting method. The experiments prove that the method is efficient for reduction of the debugging time and for the improvement of the image quality.

  15. Methods for separation/purification utilizing rapidly cycled thermal swing sorption

    DOEpatents

    Tonkovich, Anna Lee Y.; Monzyk, Bruce F.; Wang, Yong; VanderWiel, David P.; Perry, Steven T.; Fitzgerald, Sean P.; Simmons, Wayne W.; McDaniel, Jeffrey S.; Weller, Jr., Albert E.

    2004-11-09

    The present invention provides apparatus and methods for separating fluid components. In preferred embodiments, the apparatus and methods utilize microchannel devices with small distances for heat and mass transfer to achieve rapid cycle times and surprisingly large volumes of fluid components separated in short times using relatively compact hardware.

  16. A rapid method for determining salinomycin and monensin sensitivity in Eimeria tenella

    USDA-ARS?s Scientific Manuscript database

    Standard methods of determining the ionophore sensitivity of Eimeria rely on infecting chickens with an isolate or a mixture of Eimeria spp. oocysts in the presence of different anti-coccidial drugs. The purpose of this study was to develop a rapid in vitro method for assessing salinomycin and mone...

  17. An improved method for rapid generation and screening of Bacillus thuringiensis phage-resistant mutants.

    PubMed

    Gillis, Annika; Mahillon, Jacques

    2014-11-01

    A simple method to isolate, screen and select phage-resistant mutants of Bacillus thuringiensis was developed. The traditional double-layer agar method was improved by a combination of the spotting assay using a lytic phage, to generate the bacterial-resistant mutants, with an inverted spotting assay (ISA), to rapidly screen the candidate-resistant mutants.

  18. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    SciTech Connect

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B. )

    1990-11-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis.

  19. Radiometrically accurate FTS for atmospheric emission observations

    NASA Technical Reports Server (NTRS)

    Revercomb, H. E.; Smith, W. L.; Stromovsky, L. A.; Knuteson, R. O.; Buijs, H.

    1989-01-01

    The calibration and operational performance of an FTIR-based airborne high-resolution interferometer sounder (HIS) for use in broadband measurements of atmospheric emission at 3.8-16.6 microns are described. The radiometric and wavelength calibration procedures in the laboratory involved the use of reference black bodies at 300 and 245 K and the known wavelength of the HIS HeNe laser (corrected for FOV effects), respectively. The atmospheric verification program included downlooking observations from the NASA U2/ER2 aircraft (where resolving power of 1800-3800 was demonstrated) and uplooking observations from the ground; good agreement with data from balloon-borne radiosondes is obtained, with absolute temperature uncertainties of less than 0.5 K and reproducibilities of 0.1-0.2 K over most of the measurement domain.

  20. A Radiometric Uncertainty Tool for OLCI

    NASA Astrophysics Data System (ADS)

    Hunt, S.; Nieke, J.

    2016-08-01

    With its first satellite launched in February 2016, the Sentinel-3 mission will support Ocean, Land, Atmospheric, Emergency, Security and Cryospheric applications and related Copernicus services (http://www.copernicus.eu). One of the key payloads carried by the satellite, OLCI (Ocean and Land Colour Instrument), is a push-broom imaging spectrometer designed to image the Earth's surface in 21 spectral bands, from the visible to the near infrared, across a 1200 km swath. An understanding of the quality of the Level 1b (L1) data produced by OLCI is important for many of its applications. As such, work has been ongoing to develop a software tool to determine the per pixel uncertainty of these images to be used by L1 product users. This tool has been named OLCI-RUT (OLCI - Radiometric Uncertainty Tool) and this report provides a description of its development.

  1. GIFTS SM EDU Radiometric and Spectral Calibrations

    NASA Technical Reports Server (NTRS)

    Tian, J.; Reisse, R. a.; Johnson, D. G.; Gazarik, J. J.

    2007-01-01

    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument gathers measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration. The calibration procedures can be subdivided into three categories: the pre-calibration stage, the calibration stage, and finally, the post-calibration stage. Detailed derivations for each stage are presented in this paper.

  2. Absolute Radiometric Calibration of EUNIS-06

    NASA Technical Reports Server (NTRS)

    Thomas, R. J.; Rabin, D. M.; Kent, B. J.; Paustian, W.

    2007-01-01

    The Extreme-Ultraviolet Normal-Incidence Spectrometer (EUNIS) is a soundingrocket payload that obtains imaged high-resolution spectra of individual solar features, providing information about the Sun's corona and upper transition region. Shortly after its successful initial flight last year, a complete end-to-end calibration was carried out to determine the instrument's absolute radiometric response over its Longwave bandpass of 300 - 370A. The measurements were done at the Rutherford-Appleton Laboratory (RAL) in England, using the same vacuum facility and EUV radiation source used in the pre-flight calibrations of both SOHO/CDS and Hinode/EIS, as well as in three post-flight calibrations of our SERTS sounding rocket payload, the precursor to EUNIS. The unique radiation source provided by the Physikalisch-Technische Bundesanstalt (PTB) had been calibrated to an absolute accuracy of 7% (l-sigma) at 12 wavelengths covering our bandpass directly against the Berlin electron storage ring BESSY, which is itself a primary radiometric source standard. Scans of the EUNIS aperture were made to determine the instrument's absolute spectral sensitivity to +- 25%, considering all sources of error, and demonstrate that EUNIS-06 was the most sensitive solar E W spectrometer yet flown. The results will be matched against prior calibrations which relied on combining measurements of individual optical components, and on comparisons with theoretically predicted 'insensitive' line ratios. Coordinated observations were made during the EUNIS-06 flight by SOHO/CDS and EIT that will allow re-calibrations of those instruments as well. In addition, future EUNIS flights will provide similar calibration updates for TRACE, Hinode/EIS, and STEREO/SECCHI/EUVI.

  3. Radiometric consistency assessment of hyperspectral infrared sounders

    NASA Astrophysics Data System (ADS)

    Wang, L.; Han, Y.; Jin, X.; Chen, Y.; Tremblay, D. A.

    2015-07-01

    The radiometric and spectral consistency among the Atmospheric Infrared Sounder (AIRS), the Infrared Atmospheric Sounding Interferometer (IASI), and the Cross-track Infrared Sounder (CrIS) is fundamental for the creation of long-term infrared (IR) hyperspectral radiance benchmark datasets for both inter-calibration and climate-related studies. In this study, the CrIS radiance measurements on Suomi National Polar-orbiting Partnership (SNPP) satellite are directly compared with IASI on MetOp-A and -B at the finest spectral scale and with AIRS on Aqua in 25 selected spectral regions through one year of simultaneous nadir overpass (SNO) observations to evaluate radiometric consistency of these four hyperspectral IR sounders. The spectra from different sounders are paired together through strict spatial and temporal collocation. The uniform scenes are selected by examining the collocated Visible Infrared Imaging Radiometer Suite (VIIRS) pixels. Their brightness temperature (BT) differences are then calculated by converting the spectra onto common spectral grids. The results indicate that CrIS agrees well with IASI on MetOp-A and IASI on MetOp-B at the longwave IR (LWIR) and middle-wave IR (MWIR) bands with 0.1-0.2 K differences. There are no apparent scene-dependent patterns for BT differences between CrIS and IASI for individual spectral channels. CrIS and AIRS are compared at the 25 spectral regions for both Polar and Tropical SNOs. The combined global SNO datasets indicate that, the CrIS-AIRS BT differences are less than or around 0.1 K among 21 of 25 comparison spectral regions and they range from 0.15 to 0.21 K in the remaining 4 spectral regions. CrIS-AIRS BT differences in some comparison spectral regions show weak scene-dependent features.

  4. Radiometric consistency assessment of hyperspectral infrared sounders

    NASA Astrophysics Data System (ADS)

    Wang, L.; Han, Y.; Jin, X.; Chen, Y.; Tremblay, D. A.

    2015-11-01

    The radiometric and spectral consistency among the Atmospheric Infrared Sounder (AIRS), the Infrared Atmospheric Sounding Interferometer (IASI), and the Cross-track Infrared Sounder (CrIS) is fundamental for the creation of long-term infrared (IR) hyperspectral radiance benchmark data sets for both intercalibration and climate-related studies. In this study, the CrIS radiance measurements on Suomi National Polar-orbiting Partnership (SNPP) satellite are directly compared with IASI on MetOp-A and MetOp-B at the finest spectral scale and with AIRS on Aqua in 25 selected spectral regions through simultaneous nadir overpass (SNO) observations in 2013, to evaluate radiometric consistency of these four hyperspectral IR sounders. The spectra from different sounders are paired together through strict spatial and temporal collocation. The uniform scenes are selected by examining the collocated Visible Infrared Imaging Radiometer Suite (VIIRS) pixels. Their brightness temperature (BT) differences are then calculated by converting the spectra onto common spectral grids. The results indicate that CrIS agrees well with IASI on MetOp-A and IASI on MetOp-B at the long-wave IR (LWIR) and middle-wave IR (MWIR) bands with 0.1-0.2 K differences. There are no apparent scene-dependent patterns for BT differences between CrIS and IASI for individual spectral channels. CrIS and AIRS are compared at the 25 spectral regions for both polar and tropical SNOs. The combined global SNO data sets indicate that the CrIS-AIRS BT differences are less than or around 0.1 K among 21 of 25 spectral regions and they range from 0.15 to 0.21 K in the remaining four spectral regions. CrIS-AIRS BT differences in some comparison spectral regions show weak scene-dependent features.

  5. Rapid fusion method for determination of plutonium isotopes in large rice samples

    SciTech Connect

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2013-04-30

    A new rapid fusion method for the determination of plutonium in large rice samples has been developed at the Savannah River National Laboratory (Aiken, SC, USA) that can be used to determine very low levels of plutonium isotopes in rice. The recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid, reliable radiochemical analyses for radionuclides in environmental and food samples. Public concern regarding foods, particularly foods such as rice in Japan, highlights the need for analytical techniques that will allow very large sample aliquots of rice to be used for analysis so that very low levels of plutonium isotopes may be detected. The new method to determine plutonium isotopes in large rice samples utilizes a furnace ashing step, a rapid sodium hydroxide fusion method, a lanthanum fluoride matrix removal step, and a column separation process with TEVA Resin cartridges. The method can be applied to rice sample aliquots as large as 5 kg. Plutonium isotopes can be determined using alpha spectrometry or inductively-coupled plasma mass spectrometry (ICP-MS). The method showed high chemical recoveries and effective removal of interferences. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory plutonium particles are effectively digested. The MDA for a 5 kg rice sample using alpha spectrometry is 7E-5 mBq g{sup -1}. The method can easily be adapted for use by ICP-MS to allow detection of plutonium isotopic ratios.

  6. Scalable method to produce biodegradable nanoparticles that rapidly penetrate human mucus.

    PubMed

    Xu, Qingguo; Boylan, Nicholas J; Cai, Shutian; Miao, Bolong; Patel, Himatkumar; Hanes, Justin

    2013-09-10

    Mucus typically traps and rapidly removes foreign particles from the airways, gastrointestinal tract, nasopharynx, female reproductive tract and the surface of the eye. Nanoparticles capable of rapid penetration through mucus can potentially avoid rapid clearance, and open significant opportunities for controlled drug delivery at mucosal surfaces. Here, we report an industrially scalable emulsification method to produce biodegradable mucus-penetrating particles (MPP). The emulsification of diblock copolymers of poly(lactic-co-glycolic acid) and polyethylene glycol (PLGA-PEG) using low molecular weight (MW) emulsifiers forms dense brush PEG coatings on nanoparticles that allow rapid nanoparticle penetration through fresh undiluted human mucus. In comparison, conventional high MW emulsifiers, such as polyvinyl alcohol (PVA), interrupts the PEG coating on nanoparticles, resulting in their immobilization in mucus owing to adhesive interactions with mucus mesh elements. PLGA-PEG nanoparticles with a wide range of PEG MW (1, 2, 5, and 10 kDa), prepared by the emulsification method using low MW emulsifiers, all rapidly penetrated mucus. A range of drugs, from hydrophobic small molecules to hydrophilic large biologics, can be efficiently loaded into biodegradable MPP using the method described. This readily scalable method should facilitate the production of MPP products for mucosal drug delivery, as well as potentially longer-circulating particles following intravenous administration.

  7. Improved capabilities of the Chinese high-resolution remote sensing satellite GF-1 for monitoring suspended particulate matter (SPM) in inland waters: Radiometric and spatial considerations

    NASA Astrophysics Data System (ADS)

    Li, Jian; Chen, Xiaoling; Tian, Liqiao; Huang, Jue; Feng, Lian

    2015-08-01

    Dominated by high dynamic and small-scale variability, remote sensing of inland or coastal waters is frequently impended by insufficient spatial resolutions from conventional ocean color sensors. With the urgent need and the rapid progress in high-resolution earth observation systems (HR), it is critical to assess the capabilities of HR in inland water monitoring. In this study, the radiometric and spatial performance of the Chinese high-resolution GF-1 Wide Field Imager (WFI) data for water quality monitoring were evaluated in term of the signal-to-noise ratio (SNR), sensitivity to suspended particulate matter (SPM) variations and spatial depiction ability. The SNR was statistically estimated from variable moving window method, and the radiometric sensitivity was simulated using the Moderate Resolution Atmospheric Transmission (MODTRAN) under varied surface and atmospheric conditions. Results indicated that both the SNR and the radiometric sensitivity of the GF-1 WFI were enhanced by 3-5 times than its predecessor (Chinese HJ-1 CCD) or Landsat 7 Enhanced Thematic Mapper Plus (ETM+), and were comparable to Landsat 8 Operational Land Imager (OLI) and Moderate Resolution Imaging Spectroradiometer (MODIS) medium-resolution bands (250 and 500 m), which have been extensively applied in inland water environment monitoring. Cross comparisons demonstrated high consistency of the spatial distribution and concentration of SPM maps between GF-1 WFI and Landsat 8 OLI. Furthermore, more than 75% of the spatial variations in high turbid waters were resolved from GF-1 WFI data, whereas the ability dropped to 40% when the spatial resolution was degraded to 250 m (MODIS-like sensors). Overall, GF-1 WFI is extraordinarily promising with an enhanced SNR, an increased spectral sensitivity to SPM variations and an advanced spatial resolution. With the ongoing plans of the successive GF series (2-7), the findings would serve as a reference for forthcoming applications, and are critical

  8. FPGA-based data processing module design of on-board radiometric calibration in visible/near infrared bands

    NASA Astrophysics Data System (ADS)

    Zhou, Guoqing; Li, Chenyang; Yue, Tao; Liu, Na; Jiang, Linjun; Sun, Yue; Li, Mingyan

    2015-12-01

    FPGA technology has long been applied to on-board radiometric calibration data processing however the integration of FPGA program is not good enough. For example, some sensors compressed remote sensing images and transferred to ground station to calculate the calibration coefficients. It will affect the timeliness of on-board radiometric calibration. This paper designs an integrated flow chart of on-board radiometric calibration. Building FPGA-based radiometric calibration data processing modules uses system generator. Thesis focuses on analyzing the calculation accuracy of FPGA-based two-point method and verifies the feasibility of this method. Calibration data was acquired by hardware platform which was built using integrating sphere, CMOS camera (canon 60d), ASD spectrometers and light filter (center wavelength: 690nm, bandwidth: 45nm). The platform can simulate single-band on-board radiometric calibration data acquisition in visible/near infrared band. Making an experiment of calibration coefficients calculation uses obtained data and FPGA modules. Experimental results show that: the camera linearity is above 99% meeting the experimental requirement. Compares with MATLAB the calculation accuracy of two-point method by FPGA are as follows: the error of gain value is 0.0053%; the error of offset value is 0.00038719%. Those results meet experimental accuracy requirement.

  9. Rapid radiochemical method for determination of actinides in emergency concrete and brick samples.

    PubMed

    Maxwell, Sherrod L; Culligan, Brian K; Kelsey-Wall, Angel; Shaw, Patrick J

    2011-09-02

    A new rapid method for the determination of actinides in emergency concrete and brick samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations or for routine analysis. If a radiological dispersive device (RDD), Improvised Nuclear Device (IND) or nuclear accident occurs, there will be a urgent need for rapid analyses of many different environmental matrices, including building materials such as concrete and brick, to support dose mitigation and environmental clean-up. The new method for actinides in concrete and brick method utilizes a rapid sodium hydroxide fusion method, a lanthanum fluoride matrix removal step, and a column separation process with stacked TEVA, TRU and DGA Resin cartridges. Alpha emitters are prepared using rare earth microprecipitation for counting by alpha spectrometry. The method showed high chemical recoveries and effective removal of interferences. The determination of actinides in concrete and brick sample analysis can be performed in less than 8h with excellent quality for emergency samples. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory actinide particles are effectively digested.

  10. A parameter control method in reinforcement learning to rapidly follow unexpected environmental changes.

    PubMed

    Murakoshi, Kazushi; Mizuno, Junya

    2004-11-01

    In order to rapidly follow unexpected environmental changes, we propose a parameter control method in reinforcement learning that changes each of learning parameters in appropriate directions. We determine each appropriate direction on the basis of relationships between behaviors and neuromodulators by considering an emergency as a key word. Computer experiments show that the agents using our proposed method could rapidly respond to unexpected environmental changes, not depending on either two reinforcement learning algorithms (Q-learning and actor-critic (AC) architecture) or two learning problems (discontinuous and continuous state-action problems).

  11. Intraband radiometric performance of the Landsat Thematic Mappers.

    USGS Publications Warehouse

    Kieffer, H.H.; Cook, D.A.; Eliason, E.M.; Eliason, P.T.

    1985-01-01

    Radiometric characteristics have been examined of the Landsat-4 and Landsat-5 Thematic Mappers (TMs) that can be established without absolute calibration of spectral data. This analysis is based on radiometrically and geometrically raw (B-type) data of both uniform (flat-field) and high-contrast scenes. Subscenes selected for uniform radiance were used to characterized subtle radiometric differences and noise problems. Although the general performance of the Thematic Mappers is excellent, various anomalies that have a magnitude of a few digital levels (DN) or less are quantified. -from Authors

  12. Radiometric cloud imaging with an uncooled microbolometer thermal infrared camera.

    PubMed

    Shaw, Joseph; Nugent, Paul; Pust, Nathan; Thurairajah, Brentha; Mizutani, Kohei

    2005-07-25

    An uncooled microbolometer-array thermal infrared camera has been incorporated into a remote sensing system for radiometric sky imaging. The radiometric calibration is validated and improved through direct comparison with spectrally integrated data from the Atmospheric Emitted Radiance Interferometer (AERI). With the improved calibration, the Infrared Cloud Imager (ICI) system routinely obtains sky images with radiometric uncertainty less than 0.5 W/(m(2 )sr) for extended deployments in challenging field environments. We demonstrate the infrared cloud imaging technique with still and time-lapse imagery of clear and cloudy skies, including stratus, cirrus, and wave clouds.

  13. Laboratory Measurement of Bidirectional Reflectance of Radiometric Tarps

    NASA Technical Reports Server (NTRS)

    Knowlton, Kelly

    2006-01-01

    Objectives: a) To determine the magnitude of radiometric tarp BRDF; b) To determine whether an ASD FieldSpec Pro spectroradiometer can be used to perform the experiment. Radiometric tarps with nominal reflectance values of 52%, 35%, and 3.5%, deployed for IKONOS. QuickBird, and OrbView-3 overpasses Ground-based spectroradiometric measurements of tarp and Spectralon@ panel taken during overpass using ASD FieldSpec Pro spectroradiometer, and tarp reflectance calculated. Reflectance data used in atmospheric radiative transfer model (MODTRAN) to predict satellite at-sensor radiance for radiometric calibration. Reflectance data also used to validate atmospheric correction of high-spatial-resolution multispectral image products

  14. Aerial radiometric and magnetic survey: Marysvale detail survey, Richfield National Topographic Map sheet, Utah. Volume II. Radiometric multi-variable stacked profile data. Final report

    SciTech Connect

    Not Available

    1982-01-01

    The results of the analyses of a systematic airborne gamma radiation and total magnetic survey for the area identified as Marysvale, located in southwestern Utah, is presented in Volumes I-IV of this report. The airborne data gathered is reduced by ground computer facilities to yield profile plots of the equivalent uranium, thorium and potassium gamma radiation intensities, the ratios of these intensities, the total gamma radiation counting rate and the earth's residual magnetic field intensity. Profile plots of the aircraft's altitude above the earth's surface, the ambient temperature and pressure, and the magnetic field data measured by a base station magnetometer is presented also. An evaluation of the distribution of the radiometric data in terms of its established geochemical map units, which were derived via geochemical analysis methods, for the entire survey area has been prepared and is included. The determination of the geochemical units presented has been established principally from the analysis of the radiometric and magnetic contour maps and, more importantly, the multi-variate analysis map. A general description of the area, including descriptions of the various geologic and geochemical units, is included within the text. Volume II contains the 10-variable radiometric stacked profile data for the entire survey area.

  15. Method for rapid estimation of scour at highway bridges based on limited site data

    USGS Publications Warehouse

    Holnbeck, S.R.; Parrett, Charles

    1997-01-01

    Limited site data were used to develop a method for rapid estimation of scour at highway bridges. The estimates can be obtained in a matter of hours rather than several days as required by more-detailed methods. Such a method is important because scour assessments are needed to identify scour-critical bridges throughout the United States. Using detailed scour-analysis methods and scour-prediction equations recommended by the Federal Highway Administration, the U.S. Geological Survey, in cooperation with the Montana Department of Transportation, obtained contraction, pier, and abutment scour-depth data for sites from 10 States.The data were used to develop relations between scour depth and hydraulic variables that can be rapidly measured in the field. Relations between scour depth and hydraulic variables, in the form of envelope curves, were based on simpler forms of detailed scour-prediction equations. To apply the rapid-estimation method, a 100-year recurrence interval peak discharge is determined, and bridge- length data are used in the field with graphs relating unit discharge to velocity and velocity to bridge backwater as a basis for estimating flow depths and other hydraulic variables that can then be applied using the envelope curves. The method was tested in the field. Results showed good agreement among individuals involved and with results from more-detailed methods. Although useful for identifying potentially scour-critical bridges, themethod does not replace more-detailed methods used for design purposes. Use of the rapid- estimation method should be limited to individuals having experience in bridge scour, hydraulics, and flood hydrology, and some training in use of the method.

  16. Rapid assessment method for prevalence and intensity of Loa loa infection.

    PubMed Central

    Takougang, Innocent; Meremikwu, Martin; Wandji, Samuel; Yenshu, Emmanuel V.; Aripko, Ben; Lamlenn, Samson B.; Eka, Braide L.; Enyong, Peter; Meli, Jean; Kale, Oladele; Remme, Jan H.

    2002-01-01

    OBJECTIVE: To assess the validity of observations on eye worm and Calabar swellings for the rapid assessment of the prevalence and intensity of loiasis at the community level. METHOD: A total of 12895 individuals over the age of 15 years living in 102 communities in Cameroon and Nigeria took part in the study. A standardized questionnaire was administered to participants from whom finger-prick blood samples were collected and examined for Loa loa microfilariae. Rapid assessments of the prevalence and intensity of loiasis were made on the basis of a history of eye worm or Calabar swellings. FINDINGS: There was a strong correlation between the indices of the rapid assessment procedures and the parasitological indices of L. loa endemicity. The rapid assessment indices were effective in diagnosing high-risk communities (sensitivity 94-100%; specificity 66-92%). The highest sensitivity (100%) and specificity (92%) were obtained with a rapid assessment procedure based on a history of eye worm lasting 1-7 days together with confirmation by the guided recognition of a photograph of adult L. loa in the eye. CONCLUSION: Rapid assessment of the prevalence and intensity of loiasis at the community level can be achieved using a procedure based on the history of eye worm lasting 1-7 days together with confirmation by the guided recognition of a photograph of an adult L. loa in the eye. PMID:12481206

  17. Establishment and application of an efficient, economic, and rapid rice DNA extraction method

    USDA-ARS?s Scientific Manuscript database

    A rapid, economic, and efficient method for DNA extraction from rice leaf, root and seed was developed, and the extracted DNA was used as a template to successfully amplify the rice blast resistance gene Pi-ta. Profiles of Pi-ta in 165 breeding lines detected by DNA markers were verified using diff...

  18. RAPID AND PRECISE METHOD FOR MEASURING STABLE CARBON ISOTOPE RATIOS OF DISSOLVED INORGANIC CARBON

    EPA Science Inventory

    We describe a method for rapid preparation, concentration and stable isotopic analysis of dissolved inorganic carbon (d13C-DIC). Liberation of CO2 was accomplished by placing 100 ?l phosphoric acid and 0.9 ml water in an evacuated 1.7-ml gas chromatography (GC) injection vial. Fo...

  19. A critical analysis of methods for rapid and nondestructive determination of wood density in standing trees

    Treesearch

    Shan Gao; Xiping Wang; Michael C. Wiemann; Brian K. Brashaw; Robert J. Ross; Lihai Wang

    2017-01-01

    Key message Field methods for rapid determination of wood density in trees have evolved from increment borer, torsiometer, Pilodyn, and nail withdrawal into sophisticated electronic tools of resistance drilling measurement. A partial resistance drilling approach coupled with knowledge of internal tree density distribution may...

  20. RAPID AND PRECISE METHOD FOR MEASURING STABLE CARBON ISOTOPE RATIOS OF DISSOLVED INORGANIC CARBON

    EPA Science Inventory

    We describe a method for rapid preparation, concentration and stable isotopic analysis of dissolved inorganic carbon (d13C-DIC). Liberation of CO2 was accomplished by placing 100 ?l phosphoric acid and 0.9 ml water in an evacuated 1.7-ml gas chromatography (GC) injection vial. Fo...

  1. A method for the rapid qualitative and quantitative analysis of 4,4-dimethyl sterols.

    PubMed

    Gibbons, G F; Mitropoulos, K A; Ramananda, K

    1973-09-01

    A simple and relatively rapid technique has been developed for the separation of several 4,4-dimethyl steryl acetates, some of which contain sterically hindered nuclear double bonds. The method involves thin-layer chromatography on silver nitrate-impregnated silica gel and silver nitrate-impregnated alumina. The separated steryl acetates may then be analyzed quantitatively by gas-liquid chromatography.

  2. Rapid method for the detection and quantification of N-nitrosodibutylamine in rubber products.

    PubMed

    Zwickenpflug, W; Richter, E

    1987-11-01

    A rapid method for the detection and quantification of N-nitrosodibutylamine (NDBA) migrating from rubber products into a neutral buffer solution is described. The extraction, clean up, and concentration is done by a one-step procedure using C18 cartridges. NDBA in the ppb range is identified and quantitated by gas chromatography (GC) with a thermal energy analyzer (TEA) as detector.

  3. A Rapid Method for BrdU Immunostaining in Bovine Mammary Cryosections that Retains RNA Quality

    USDA-ARS?s Scientific Manuscript database

    A rapid method of 5-bromo-2’-deoxyuridine (BrdU) immunostaining was developed in cryosections of bovine mammary tissue, while preserving RNA quality of the stained section. BrdU is a thymidine analog that is incorporated into DNA of proliferating cells and thus serves as a proliferation marker. Im...

  4. Collision-induced fragmentation accurate mass spectrometric analysis methods to rapidly characterize phytochemicals in plant extracts

    USDA-ARS?s Scientific Manuscript database

    The rapid advances in analytical chromatography equipment have made the reliable and reproducible measurement of a wide range of plant chemical components possible. Full chemical characterization of a given plant material is possible with the new mass spectrometers currently available. New methods a...

  5. A Rapid Method for Measuring Strontium-90 Activity in Crops in China

    NASA Astrophysics Data System (ADS)

    Pan, Lingjing Pan; Yu, Guobing; Wen, Deyun; Chen, Zhi; Sheng, Liusi; Liu, Chung-King; Xu, X. George

    2017-09-01

    A rapid method for measuring Sr-90 activity in crop ashes is presented. Liquid scintillation counting, combined with ion exchange columns 4`, 4"(5")-di-t-butylcyclohexane-18-crown-6, is used to determine the activity of Sr-90 in crops. The yields of chemical procedure are quantified using gravimetric analysis. The conventional method that uses ion-exchange resin with HDEHP could not completely remove all the bismuth when comparatively large lead and bismuth exist in the samples. This is overcome by the rapid method. The chemical yield of this method is about 60% and the MDA for Sr-90 is found to be 2:32 Bq/kg. The whole procedure together with using spectrum analysis to determine the activity only takes about one day, which is really a large improvement compared with the conventional method. A modified conventional method is also described here to verify the value of the rapid one. These two methods can meet di_erent needs of daily monitoring and emergency situation.

  6. MODIS On-orbit Radiometric Calibration Algorithms

    NASA Astrophysics Data System (ADS)

    Xiong, X.; Chiang, K.; Adimi, F.; Sun, J.; Esposito, J.; Barnes, W. L.

    2002-05-01

    The MODerate Resolution Imaging Spectroradiometer (MODIS), a key instrument for NASA's Earth Observing System (EOS), consists of 36 spectral bands with wavelengths ranging form 0.41 micron to 14.4 microns and spatial resolutions of 0.25km (2 bands), 0.5km (5 bands), and 1.0km at nadir. The 36 spectral bands are distributed on four Focal Plane Assemblies (FPA): visible (VIS), near-infrared (NIR), short- and mid-wave infrared (SMIR), and long-wave infrared (LWIR). A Spectral Radiometric Calibration Assembly (SRCA), built into the MODIS instrument, is used to characterize the relative band to band registration and VIS and NIR bands' spectral stability. The MODIS 2-sided paddle wheel scan mirror provides a -55 degree to +55 degree scan of the Earth covering a 10km (at nadir) along track by 2330km along scan swath. The MODIS ProtoFlight Model (PFM) was launched on-board the EOS Terra spacecraft on December 18, 1999 (Sun-synchronous near polar orbit, 10:30 am equator crossing time, descending node). MODIS has been providing the science community global coverage of the land, oceans, and atmosphere. A second instrument, the Flight Model 1 (FM1), will be launched on the EOS Aqua spacecraft in April 2002 (Sun-synchronous near polar orbit, 1:30 pm equator crossing time, ascending node). The MODIS Characterization Support Team (MCST), funded by the MODIS Science Team, is responsible for the instrument pre-launch and on-orbit calibration and characterization and for developing, maintaining, and improving the Level 1B algorithm that converts the instrument digital counts to radiometrically calibrated top of the atmosphere (TOA) radiance and reflectance products. The Level1B data, along with other science products (oceans, land, and atmosphere), are freely available to the public through NASA Goddard Earth Science (GES) Distributed Active Archive Center (DAAC). The MODIS 20 reflective solar bands (RSB) from 0.41 to 2.1 microns are calibrated on-orbit by a solar diffuser (SD) and

  7. Rapid method for determination of carbonyl groups in lignin compounds by headspace gas chromatography.

    PubMed

    Li, Jing; Hu, Hui-Chao; Chai, Xin-Sheng

    2015-07-24

    The paper reports on a novel method for rapid determination of carbonyl in lignins by headspace gas chromatography (HS-GC). The method involves the quantitative carbonyl reduction for aldehydes in 2min at room temperature or for acetones in 30min at 80°C by sodium borohydride solution in a closed headspace sample vial. After the reaction, the solution was acidified by injecting sulfuric acid solution and the hydrogen released to the headspace was determined by GC using thermal-conductivity detector. The results showed that with the addition of SiO2 powder, the reduction reaction of carbonyl groups can be greatly facilitated. The method has a good measurement precision (RSD<7.74%) and accuracy (relative error <10% compared with a reference method) in the carbonyl quantification. It is suitable to be used for rapid determination of carbonyl content in lignin and related materials.

  8. Relative Radiometric Normalization and Atmospheric Correction of a SPOT 5 Time Series

    PubMed Central

    Hajj, Mahmoud El; Bégué, Agnès; Lafrance, Bruno; Hagolle, Olivier; Dedieu, Gérard; Rumeau, Matthieu

    2008-01-01

    Multi-temporal images acquired at high spatial and temporal resolution are an important tool for detecting change and analyzing trends, especially in agricultural applications. However, to insure a reliable use of this kind of data, a rigorous radiometric normalization step is required. Normalization can be addressed by performing an atmospheric correction of each image in the time series. The main problem is the difficulty of obtaining an atmospheric characterization at a given acquisition date. In this paper, we investigate whether relative radiometric normalization can substitute for atmospheric correction. We develop an automatic method for relative radiometric normalization based on calculating linear regressions between unnormalized and reference images. Regressions are obtained using the reflectances of automatically selected invariant targets. We compare this method with an atmospheric correction method that uses the 6S model. The performances of both methods are compared using 18 images from of a SPOT 5 time series acquired over Reunion Island. Results obtained for a set of manually selected invariant targets show excellent agreement between the two methods in all spectral bands: values of the coefficient of determination (r2 exceed 0.960, and bias magnitude values are less than 2.65. There is also a strong correlation between normalized NDVI values of sugarcane fields (r2 = 0.959). Despite a relative error of 12.66% between values, very comparable NDVI patterns are observed. PMID:27879849

  9. Rapid qualitative research methods during complex health emergencies: A systematic review of the literature.

    PubMed

    Johnson, Ginger A; Vindrola-Padros, Cecilia

    2017-09-01

    The 2013-2016 Ebola outbreak in West Africa highlighted both the successes and limitations of social science contributions to emergency response operations. An important limitation was the rapid and effective communication of study findings. A systematic review was carried out to explore how rapid qualitative methods have been used during global heath emergencies to understand which methods are commonly used, how they are applied, and the difficulties faced by social science researchers in the field. We also asses their value and benefit for health emergencies. The review findings are used to propose recommendations for qualitative research in this context. Peer-reviewed articles and grey literature were identified through six online databases. An initial search was carried out in July 2016 and updated in February 2017. The PRISMA checklist was used to guide the reporting of methods and findings. The articles were assessed for quality using the MMAT and AACODS checklist. From an initial search yielding 1444 articles, 22 articles met the criteria for inclusion. Thirteen of the articles were qualitative studies and nine used a mixed-methods design. The purpose of the rapid studies included: the identification of causes of the outbreak, and assessment of infrastructure, control strategies, health needs and health facility use. The studies varied in duration (from 4 days to 1 month). The main limitations identified by the authors were: the low quality of the collected data, small sample sizes, and little time for cross-checking facts with other data sources to reduce bias. Rapid qualitative methods were seen as beneficial in highlighting context-specific issues that need to be addressed locally, population-level behaviors influencing health service use, and organizational challenges in response planning and implementation. Recommendations for carrying out rapid qualitative research in this context included the early designation of community leaders as a point of

  10. Adjustment of a rapid method for quantification of Fusarium spp. spore suspensions in plant pathology.

    PubMed

    Caligiore-Gei, Pablo F; Valdez, Jorge G

    2015-01-01

    The use of a Neubauer chamber is a broadly employed method when cell suspensions need to be quantified. However, this technique may take a long time and needs trained personnel. Spectrophotometry has proved to be a rapid, simple and accurate method to estimate the concentration of spore suspensions of isolates of the genus Fusarium. In this work we present a linear formula to relate absorbance measurements at 530nm with the number of microconidia/ml in a suspension.

  11. Apparatus and method for rapid separation and detection of hydrocarbon fractions in a fluid stream

    DOEpatents

    Sluder, Charles S.; Storey, John M.; Lewis, Sr., Samuel A.

    2013-01-22

    An apparatus and method for rapid fractionation of hydrocarbon phases in a sample fluid stream are disclosed. Examples of the disclosed apparatus and method include an assembly of elements in fluid communication with one another including one or more valves and at least one sorbent chamber for removing certain classifications of hydrocarbons and detecting the remaining fractions using a detector. The respective ratios of hydrocarbons are determined by comparison with a non separated fluid stream.

  12. Rapid methods for the extraction and archiving of molecular grade fungal genomic DNA.

    PubMed

    Borman, Andrew M; Palmer, Michael; Johnson, Elizabeth M

    2013-01-01

    The rapid and inexpensive extraction of fungal genomic DNA that is of sufficient quality for molecular approaches is central to the molecular identification, epidemiological analysis, taxonomy, and strain typing of pathogenic fungi. Although many commercially available and in-house extraction procedures do eliminate the majority of contaminants that commonly inhibit molecular approaches, the inherent difficulties in breaking fungal cell walls lead to protocols that are labor intensive and that routinely take several hours to complete. Here we describe several methods that we have developed in our laboratory that allow the extremely rapid and inexpensive preparation of fungal genomic DNA.

  13. Application of a rapid screening method to detect irradiated meat in Brazil

    NASA Astrophysics Data System (ADS)

    Villavicencio, A. L. C. H. A. L. C. H.; Mancini-Filho, J. J.; Delincée, H.

    2000-03-01

    Based on the enormous potential for food irradiation in Brazil, and to ensure free consumer choice, there is a need to find a convenient and rapid method for detection of irradiated food. Since treatment with ionising radiation causes DNA fragmentation, the analysis of DNA damage might be promising. In this paper, the DNA Comet Assay was used to identify exotic meat (boar, jacaré and capybara), irradiated with 60Co gamma rays. The applied radiation doses were 0, 1.5, 3.0 and 4.5 kGy. Analysis of the DNA migration enabled a rapid identification of the radiation treatment.

  14. PHASS99: A software program for retrieving and decoding the radiometric ages of igneous rocks from the international database IGBADAT

    NASA Astrophysics Data System (ADS)

    Al-Mishwat, Ali T.

    2016-05-01

    PHASS99 is a FORTRAN program designed to retrieve and decode radiometric and other physical age information of igneous rocks contained in the international database IGBADAT (Igneous Base Data File). In the database, ages are stored in a proprietary format using mnemonic representations. The program can handle up to 99 ages in an igneous rock specimen and caters to forty radiometric age systems. The radiometric age alphanumeric strings assigned to each specimen description in the database consist of four components: the numeric age and its exponential modifier, a four-character mnemonic method identification, a two-character mnemonic name of analysed material, and the reference number in the rock group bibliography vector. For each specimen, the program searches for radiometric age strings, extracts them, parses them, decodes the different age components, and converts them to high-level English equivalents. IGBADAT and similarly-structured files are used for input. The output includes three files: a flat raw ASCII text file containing retrieved radiometric age information, a generic spreadsheet-compatible file for data import to spreadsheets, and an error file. PHASS99 builds on the old program TSTPHA (Test Physical Age) decoder program and expands greatly its capabilities. PHASS99 is simple, user friendly, fast, efficient, and does not require users to have knowledge of programing.

  15. Validation of Rapid Assessment Methods to Determine Streamflow Duration Classes in the Pacific Northwest, USA

    NASA Astrophysics Data System (ADS)

    Nadeau, Tracie-Lynn; Leibowitz, Scott G.; Wigington, Parker J.; Ebersole, Joseph L.; Fritz, Ken M.; Coulombe, Robert A.; Comeleo, Randy L.; Blocksom, Karen A.

    2015-07-01

    United States Supreme Court rulings have created uncertainty regarding U.S. Clean Water Act (CWA) authority over certain waters, and established new data and analytical requirements for determining CWA jurisdiction. Thus, rapid assessment methods are needed that can differentiate between ephemeral, intermittent, and perennial streams. We report on the validation of several methods. The first (Interim Method) was developed through best professional judgment (BPJ); an alternative (Revised Method) resulted from statistical analysis. We tested the Interim Method on 178 study reaches in Oregon, and constructed the Revised Method based on statistical analysis of the Oregon data. Next, we evaluated the regional applicability of the methods on 86 study reaches across a variety of hydrologic landscapes in Washington and Idaho. During the second phase, we also compared the Revised Method with a similar approach (Combined Method) based on combined field data from Oregon, Washington, and Idaho. We further compared field-based methods with a GIS-based approach (GIS Method) that used the National Hydrography Dataset and a synthetic stream network. Evaluations of all methods compared results with actual streamflow duration classes. The Revised Method correctly determined known streamflow duration 83.9 % of the time, versus 62.3 % accuracy of the Interim Method and 43.6 % accuracy for the GIS-based approach. The Combined Method did not significantly outperform the Revised Method. Analysis showed biological indicators most accurately discriminate streamflow duration classes. While BPJ established a testable hypothesis, this study illustrates the importance of quantitative field testing of rapid assessment methods. Results support a consistent method applicable across the Pacific Northwest.

  16. Rapid complementation method for classifying excision repair-defective xeroderma pigmentosum cell strains.

    PubMed

    Cleaver, J E

    1982-11-01

    A rapid method has been developed that permits demonstration of complementation between different cell strains from ultraviolet-sensitive xeroderma pigmentosum patients. Combining polyethylene glycol-mediated cell fusion with low doses of ultraviolet light to eliminate unfused sensitive cells, the method permits assignment of cell strains to complementation groups by visual inspection, avoiding use of laborious methods involving autoradiography. This method can be augmented by measuring DNA repair synthesis, which shows large quantitative differences between fusions that result in complementation and those that do not.

  17. A rapid, quantitative GLC method for the simultaneous determination of nicotine and cotinine.

    PubMed

    Verebey, K G; DePace, A; Mulé, S J; Kanzler, M; Jaffe, J H

    1982-01-01

    Published gas-liquid chromatographic (GLC) methods for the determination of nicotine and cotinine have proved impractical for the analysis of a large number of clinical samples. Significant improvements over other methods have been achieved, being low sample volume (0.5 mL plasma), rapid two-step extraction from plasma, no evaporation step, and good separation. The lower limits of sensitivity for nicotine and cotinine were 1 and 5 ng/mL, respectively. The method was validated by the analysis of plasma samples from cigarette-smoking volunteers. The method described permits the quick, routine determination of nicotine and cotinine in a large number of samples.

  18. Seed oil polyphenols: rapid and sensitive extraction method and high resolution-mass spectrometry identification.

    PubMed

    Koubaa, Mohamed; Mhemdi, Houcine; Vorobiev, Eugène

    2015-05-01

    Phenolic content is a primary parameter for vegetables oil quality evaluation, and directly involved in the prevention of oxidation and oil preservation. Several methods have been reported in the literature for polyphenols extraction from seed oil but the approaches commonly used remain manually handled. In this work, we propose a rapid and sensitive method for seed oil polyphenols extraction and identification. For this purpose, polyphenols were extracted from Opuntia stricta Haw seed oil, using high frequency agitation, separated, and then identified using a liquid chromatography-high resolution mass spectrometry method. Our results showed good sensitivity and reproducibility of the developed methods.

  19. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements

    DTIC Science & Technology

    2013-09-30

    Radiometric Measurements Dick K.P. Yue Center for Ocean Engineering Massachusetts Institute of Technology Room 5-321 77 Massachusetts Ave...comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 30 SEP 2013 2. REPORT TYPE 3. DATES ...COVERED 00-00-2013 to 00-00-2013 4. TITLE AND SUBTITLE Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements 5a

  20. Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurement

    DTIC Science & Technology

    2013-09-30

    Radiometric Measurement Lian Shen Department of Mechanical Engineering & St. Anthony Falls Laboratory University of Minnesota Minneapolis, MN...information if it does not display a currently valid OMB control number. 1. REPORT DATE 30 SEP 2013 2. REPORT TYPE 3. DATES COVERED 00-00-2013 to 00-00...2013 4. TITLE AND SUBTITLE Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurement 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  1. Radiometric Measurements of Powerline Cables at 94 GHz

    DTIC Science & Technology

    2001-02-01

    ARMY RESEARCH LABORATORY Radiometric Measurements of Powerline Cables at 94 GHz David A. Wikner and Thomas J. Pizzillo ARL-TR-837 February 2001...MD 20783-1197 ARL-TR-837 February 2001 Radiometric Measurements of Powerline Cables at 94 GHz David A. Wikner and Thomas J. Pizzillo Sensors and...collision avoidance system," Proc. SPIE 3088 (April 1997), pp 57-63. 5. D. Wikner and T. Pizzillo, "Measurement of nadir and near-nadir 94-GHz

  2. Airborne Visible/Infrared Imaging Spectrometer (AVIRIS): Inflight radiometric calibration and the determination of surface reflectance

    NASA Technical Reports Server (NTRS)

    Conel, J. E.; Vane, G.; Green, R. O.; Alley, R. E.; Carere, V.; Gabell, A.; Bruegge, C. J.

    1988-01-01

    The inflight radiometric performance of AVIRIS is presented together with a comparison of methods of recovering surface spectral reflectance from the data. Performance is evaluated by comparing radiance predicted from AVIRIS with radiance generated from the LOWIRAN 6 atmospheric model and measured surface reflectance. Comparisons show apparent agreement to within a few percent between 1800 and 2450 nm. Between 600 and 1800 nm the response of AVIRIS is systematically low by as much as 70 percent, and between 400 and 600 nm it is higher than expected. These problems are traced to thermal distortions of the instrument, and to detachment during flight of optical fibers connecting foreoptics to two of four spectrometers in the instrument. Of three methods studied, an empirical one involving calibration curves constructed from field reflectance measurements returns accurate predictions of the surface reflectance independent of the actual radiometric significance of the flight data.

  3. The Radiometric Bode's Law and Extrasolar Planets

    NASA Astrophysics Data System (ADS)

    Lazio, T. Joseph, W.; Farrell, W. M.; Dietrick, Jill; Greenlees, Elizabeth; Hogan, Emily; Jones, Christopher; Hennig, L. A.

    2004-09-01

    We predict the radio flux densities of the extrasolar planets in the current census, making use of an empirical relation-the radiometric Bode's law-determined from the five ``magnetic'' planets in the solar system (the Earth and the four gas giants). Radio emission from these planets results from solar wind-powered electron currents depositing energy in the magnetic polar regions. We find that most of the known extrasolar planets should emit in the frequency range 10-1000 MHz and, under favorable circumstances, have typical flux densities as large as 1 mJy. We also describe an initial, systematic effort to search for radio emission in low radio frequency images acquired with the Very Large Array (VLA). The limits set by the VLA images (~300 mJy) are consistent with, but do not provide strong constraints on, the predictions of the model. Future radio telescopes, such as the Low Frequency Array and the Square Kilometer Array, should be able to detect the known extrasolar planets or place austere limits on their radio emission. Planets with masses much lower than those in the current census will probably radiate below 10 MHz and will require a space-based array.

  4. Calibrated infrared ground/air radiometric spectrometer

    NASA Astrophysics Data System (ADS)

    Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.

    1996-06-01

    The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).

  5. Blast investigation by fast multispectral radiometric analysis

    NASA Astrophysics Data System (ADS)

    Devir, A. D.; Bushlin, Y.; Mendelewicz, I.; Lessin, A. B.; Engel, M.

    2011-06-01

    Knowledge regarding the processes involved in blasts and detonations is required in various applications, e.g. missile interception, blasts of high-explosive materials, final ballistics and IED identification. Blasts release large amount of energy in short time duration. Some part of this energy is released as intense radiation in the optical spectral bands. This paper proposes to measure the blast radiation by a fast multispectral radiometer. The measurement is made, simultaneously, in appropriately chosen spectral bands. These spectral bands provide extensive information on the physical and chemical processes that govern the blast through the time-dependence of the molecular and aerosol contributions to the detonation products. Multi-spectral blast measurements are performed in the visible, SWIR and MWIR spectral bands. Analysis of the cross-correlation between the measured multi-spectral signals gives the time dependence of the temperature, aerosol and gas composition of the blast. Farther analysis of the development of these quantities in time may indicate on the order of the detonation and amount and type of explosive materials. Examples of analysis of measured explosions are presented to demonstrate the power of the suggested fast multispectral radiometric analysis approach.

  6. The use of rapid review methods in health technology assessments: 3 case studies.

    PubMed

    Kaltenthaler, Eva; Cooper, Katy; Pandor, Abdullah; Martyn-St James, Marrissa; Chatters, Robin; Wong, Ruth

    2016-08-26

    Rapid reviews are of increasing importance within health technology assessment due to time and resource constraints. There are many rapid review methods available although there is little guidance as to the most suitable methods. We present three case studies employing differing methods to suit the evidence base for each review and outline some issues to consider when selecting an appropriate method. Three recently completed systematic review short reports produced for the UK National Institute for Health Research were examined. Different approaches to rapid review methods were used in the three reports which were undertaken to inform the commissioning of services within the NHS and to inform future trial design. We describe the methods used, the reasoning behind the choice of methods and explore the strengths and weaknesses of each method. Rapid review methods were chosen to meet the needs of the review and each review had distinctly different challenges such as heterogeneity in terms of populations, interventions, comparators and outcome measures (PICO) and/or large numbers of relevant trials. All reviews included at least 10 randomised controlled trials (RCTs), each with numerous included outcomes. For the first case study (sexual health interventions), very diverse studies in terms of PICO were included. P-values and summary information only were presented due to substantial heterogeneity between studies and outcomes measured. For the second case study (premature ejaculation treatments), there were over 100 RCTs but also several existing systematic reviews. Data for meta-analyses were extracted directly from existing systematic reviews with new RCT data added where available. For the final case study (cannabis cessation therapies), studies included a wide range of interventions and considerable variation in study populations and outcomes. A brief summary of the key findings for each study was presented and narrative synthesis used to summarise results for each

  7. [A new rapid antibiotic susceptibility test for enteric bacteria using a color change method].

    PubMed

    Kocagöz, T; Hayran, M; Kocagöz, S

    1988-01-01

    The rapid antibiotic susceptibility tests that have been developed so far cannot be used in daily work, because of their many difficulties and disadvantages. We have developed a new antibiotic susceptibility test for enteric bacteria which gives the result in 4 hours, easy to perform and inexpensive. This method depends upon the mechanism which detects the acid formed by the bacteria, by the change of the color of the pH indicator in the medium. The susceptibility of 110 different isolates of enteric bacteria (E. coli, Klebsiella, Salmonella, Shigella, Proteus, Enterobacter) to ampicillin, amikacin, trimethoprim-sulfamethoxazole, cephradine, cefazolin, erythromycin, gentamicin, and ofloxacin is examined by this new "Rapid Color Change Test" and disc diffusion method. For most organisms tested, there was a good correlation between the results of the two methods. The overall agreement is found to be 91.43%.

  8. A rapid electrothermal atomic absorption spectrophotometric method for cadmium and lead in human whole blood.

    PubMed

    Subramanian, K S; Meranger, J C

    1981-11-01

    A rapid graphite-furnace atomic absorption spectrophotometric procedure is described for determining cadmium and lead in heparinized human whole blood. A known aliquot of the blood sample is diluted fivefold with an aqueous solution composed of 5 g each of diammonium hydrogen phosphate and Triton X-100 per liter, the solution is vigorously agitated, and a 10-microL aliquot is injected into a pyrocoated graphite tube under optimized instrumental conditions. Values for Cd and Pb in the sample are obtained by direct comparison to linear working curves prepared from aqueous standards of the metals in the diammonium hydrogen phosphate-Triton medium; there is no need to use the method of standard addition or matrix-matched calibration curves. Also, the method is free of matrix effects. At least 30 samples can be analyzed per hour. The rapidity, simplicity, and sensitivity of the method make it attractive as a screening technique for routine environmental surveillance involving large throughput of samples.

  9. Studies on the Rapid Methods for Evaluating Seed Vigor of Sweet Corn

    NASA Astrophysics Data System (ADS)

    Zhao, Guangwu; Yang, Linlin; Wang, Jianhua; Zhu, Zhujun

    Since the germination test is still the main method for evaluating seed vigor of sweet corn, it is necessary to study the rapid methods for evaluating their vigor. First, two vigor levels of 9 super sweet corn and 9 sugar enhanced corn hybrids were distinguished by accelerated ageing treatment. Next, their vigor statuses were tested by rapid methods such as electrical conductivity (EC), soluble sugar (SS), volatile aldehyde (VA), dehydrogenase activity (DA) and Q2 oxygen sensing technology. Correlation relationship was analyzed between the above tested values and vigor performances. The results showed that EC, SS, VA, DA, oxygen metabolism rate (OMR), critical oxygen pressure (COP) were all suitable to evaluate seed vigor of sweet corn. Furthermore, VA was optimal for evaluating seed vigor of super sweet corn. DA was optimal for evaluating sugar enhanced corn.

  10. A simple, low-cost staining method for rapid-throughput analysis of tumor spheroids.

    PubMed

    Eckerdt, Frank; Alvarez, Angel; Bell, Jonathan; Arvanitis, Constadina; Iqbal, Asneha; Arslan, Ahmet D; Hu, Bo; Cheng, Shi-Yuan; Goldman, Stewart; Platanias, Leonidas C

    2016-01-01

    Tumor spheroids are becoming an important tool for the investigation of cancer stem cell (CSC) function in tumors; thus, low-cost and high-throughput methods for drug screening of tumor spheroids are needed. Using neurospheres as non-adherent three-dimensional (3-D) cultures, we developed a simple, low-cost acridine orange (AO)-based method that allows for rapid analysis of live neurospheres by fluorescence microscopy in a 96-well format. This assay measures the cross-section area of a spheroid, which corresponds to cell viability. Our novel method allows rapid screening of a panel of anti-proliferative drugs to assess inhibitory effects on the growth of cancer stem cells in 3-D cultures.

  11. Determination of rapid chlorination rate constants by a stopped-flow spectrophotometric competition kinetics method.

    PubMed

    Song, Dean; Liu, Huijuan; Qiang, Zhimin; Qu, Jiuhui

    2014-05-15

    Free chlorine is extensively used for water and wastewater disinfection nowadays. However, it still remains a big challenge to determine the rate constants of rapid chlorination reactions although competition kinetics and stopped-flow spectrophotometric (SFS) methods have been employed individually to investigate fast reaction kinetics. In this work, we proposed an SFS competition kinetics method to determine the rapid chlorination rate constants by using a common colorimetric reagent, N,N-diethyl-p-phenylenediamine (DPD), as a reference probe. A kinetic equation was first derived to estimate the reaction rate constant of DPD towards chlorine under a given pH and temperature condition. Then, on that basis, an SFS competition kinetics method was proposed to determine directly the chlorination rate constants of several representative compounds including tetracycline, ammonia, and four α-amino acids. Although Cl2O is more reactive than HOCl, its contribution to the overall chlorination kinetics of the test compounds could be neglected in this study. Finally, the developed method was validated through comparing the experimentally measured chlorination rate constants of the selected compounds with those obtained or calculated from literature and analyzing with Taft's correlation as well. This study demonstrates that the SFS competition kinetics method can measure the chlorination rate constants of a test compound rapidly and accurately.

  12. Rapid Column Extraction Method for Actinides and Sr-89/90 in Water Samples

    SciTech Connect

    MAXWELL III, SHERROD L.

    2005-06-15

    The SRS Environmental Laboratory analyzes water samples for environmental monitoring, including river water and ground water samples. A new, faster actinide and strontium 89/90 separation method has been developed and implemented to improve productivity, reduce labor costs and add capacity to this laboratory. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and Sr-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), neptunium (Np), uranium (U), americium (Am), curium (Cm) and thorium (Th) using a single multi-stage column combined with alpha spectrometry. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized. The method can be used for routine analysis or as a rapid method for emergency preparedness. Thorium and curium are often analyzed separately due to the interference of the daughter of Th-229 tracer, actinium (Ac)-225, on curium isotopes when measured by alpha spectrometry. This new method also adds a separation step using DGA Resin{reg_sign}, (Diglycolamide Resin, Eichrom Technologies) to remove Ac-225 and allow the separation and analysis of thorium isotopes and curium isotopes at the same time.

  13. Rapid full-wave phase aberration correction method for transcranial high-intensity focused ultrasound therapies.

    PubMed

    Almquist, Scott; Parker, Dennis L; Christensen, Douglas A

    2016-01-01

    Non-invasive high-intensity focused ultrasound (HIFU) can be used to treat a variety of disorders, including those in the brain. However, the differences in acoustic properties between the skull and the surrounding soft tissue cause aberrations in the path of the ultrasonic beam, hindering or preventing treatment. We present a method for correcting these aberrations that is fast, full-wave, and allows for corrections at multiple treatment locations. The method is simulation-based: an acoustic model is built based on high-resolution CT scans, and simulations are performed using the hybrid angular spectrum (HAS) method to determine the phases needed for correction. Computation of corrections for clinically applicable resolutions can be achieved in approximately 15 min. Experimental results with a plastic model designed to mimic the aberrations caused by the skull show that the method can recover 95 % of the peak pressure obtained using hydrophone-based time-reversal methods. Testing using an ex vivo human skull flap resulted in recovering up to 70 % of the peak pressure at the focus and 61 % when steering (representing, respectively, a 1.52- and 1.19-fold increase in the peak pressure over the uncorrected case). Additionally, combining the phase correction method with rapid HAS simulations allows evaluation of such treatment metrics as the effect of misregistration on resulting pressure levels. The method presented here is able to rapidly compute phases required to improve ultrasound focusing through the skull at multiple treatment locations. Combining phase correction with rapid simulation techniques allows for evaluation of various treatment metrics such as the effect of steering on pressure levels. Since the method computes 3D pressure patterns, it may also be suitable for predicting off-focus hot spots during treatments-a primary concern for transcranial HIFU. Additionally, the plastic-skull method presented here may be a useful tool in evaluating the

  14. The absolute radiometric calibration of the advanced very high resolution radiometer

    NASA Technical Reports Server (NTRS)

    Slater, P. N.; Teillet, P. M.; Ding, Y.

    1988-01-01

    The need for independent, redundant absolute radiometric calibration methods is discussed with reference to the Thematic Mapper. Uncertainty requirements for absolute calibration of between 0.5 and 4 percent are defined based on the accuracy of reflectance retrievals at an agricultural site. It is shown that even very approximate atmospheric corrections can reduce the error in reflectance retrieval to 0.02 over the reflectance range 0 to 0.4.

  15. Impact of the cameras radiometric resolution on the accuracy of determining spectral reflectance coefficients

    NASA Astrophysics Data System (ADS)

    Orych, A.; Walczykowski, P.; Jenerowicz, A.; Zdunek, Z.

    2014-11-01

    Nowadays remote sensing plays a very important role in many different study fields, i.e. environmental studies, hydrology, mineralogy, ecosystem studies, etc. One of the key areas of remote sensing applications is water quality monitoring. Understanding and monitoring of the water quality parameters and detecting different water contaminants is an important issue in water management and protection of whole environment and especially the water ecosystem. There are many remote sensing methods to monitor water quality and detect water pollutants. One of the most widely used method for substance detection with remote sensing techniques is based on usage of spectral reflectance coefficients. They are usually acquired using discrete methods such as spectrometric measurements. These however can be very time consuming, therefore image-based methods are used more and more often. In order to work out the proper methodology of obtaining spectral reflectance coefficients from hyperspectral and multispectral images, it is necessary to verify the impact of cameras radiometric resolution on the accuracy of determination of them. This paper presents laboratory experiments that were conducted using two monochromatic XEVA video sensors (400-1700 nm spectral data registration) with two different radiometric resolutions (12 and 14 bits). In view of determining spectral characteristics from images, the research team used set of interferometric filters. All data collected with multispectral digital video cameras were compared with spectral reflectance coefficients obtained with spectroradiometer. The objective of this research is to find the impact of cameras radiometric resolution on reflectance values in chosen wavelength. The main topic of this study is the analysis of accuracy of spectral coefficients from sensors with different radiometric resolution. By comparing values collected from images acquired with XEVA sensors and with the curves obtained with spectroradiometer it

  16. Adapting and Evaluating a Rapid, Low-Cost Method to Enumerate Flies in the Household Setting.

    PubMed

    Wolfe, Marlene K; Dentz, Holly N; Achando, Beryl; Mureithi, MaryAnne; Wolfe, Tim; Null, Clair; Pickering, Amy J

    2017-02-08

    Diarrhea is a leading cause of death among children under 5 years of age worldwide. Flies are important vectors of diarrheal pathogens in settings lacking networked sanitation services. There is no standardized method for measuring fly density in households; many methods are cumbersome and unvalidated. We adapted a rapid, low-cost fly enumeration technique previously developed for industrial settings, the Scudder fly grill, for field use in household settings. We evaluated its performance in comparison to a sticky tape fly trapping method at latrine and food preparation areas among households in rural Kenya. The grill method was more sensitive; it detected the presence of any flies at 80% (433/543) of sampling locations versus 64% (348/543) of locations by the sticky tape. We found poor concordance between the two methods, suggesting that standardizing protocols is important for comparison of fly densities between studies. Fly species identification was feasible with both methods; however, the sticky tape trap allowed for more nuanced identification. Both methods detected a greater presence of bottle flies near latrines compared with food preparation areas (P < 0.01). The grill method detected more flies at the food preparation area compared with near the latrine (P = 0.014) while the sticky tape method detected no difference. We recommend the Scudder grill as a sensitive fly enumeration tool that is rapid and low cost to implement.

  17. Adapting and Evaluating a Rapid, Low-Cost Method to Enumerate Flies in the Household Setting

    PubMed Central

    Wolfe, Marlene K.; Dentz, Holly N.; Achando, Beryl; Mureithi, MaryAnne; Wolfe, Tim; Null, Clair; Pickering, Amy J.

    2017-01-01

    Diarrhea is a leading cause of death among children under 5 years of age worldwide. Flies are important vectors of diarrheal pathogens in settings lacking networked sanitation services. There is no standardized method for measuring fly density in households; many methods are cumbersome and unvalidated. We adapted a rapid, low-cost fly enumeration technique previously developed for industrial settings, the Scudder fly grill, for field use in household settings. We evaluated its performance in comparison to a sticky tape fly trapping method at latrine and food preparation areas among households in rural Kenya. The grill method was more sensitive; it detected the presence of any flies at 80% (433/543) of sampling locations versus 64% (348/543) of locations by the sticky tape. We found poor concordance between the two methods, suggesting that standardizing protocols is important for comparison of fly densities between studies. Fly species identification was feasible with both methods; however, the sticky tape trap allowed for more nuanced identification. Both methods detected a greater presence of bottle flies near latrines compared with food preparation areas (P < 0.01). The grill method detected more flies at the food preparation area compared with near the latrine (P = 0.014) while the sticky tape method detected no difference. We recommend the Scudder grill as a sensitive fly enumeration tool that is rapid and low cost to implement. PMID:27956654

  18. Revised Radiometric Calibration Technique for LANDSAT-4 Thematic Mapper Data by the Canada Centre for Remote Sensing

    NASA Technical Reports Server (NTRS)

    Murphy, J.; Butlin, T.; Duff, P.; Fitzgerald, A.

    1984-01-01

    A technique for the radiometric correction of LANDSAT-4 Thematic Mapper data was proposed by the Canada Center for Remote Sensing. Subsequent detailed observations of raw image data, raw radiometric calibration data and background measurements extracted from the raw data stream on High Density Tape highlighted major shortcomings in the proposed method which if left uncorrected, can cause severe radiometric striping in the output product. Results are presented which correlate measurements of the DC background with variations in both image data background and calibration samples. The effect on both raw data and on data corrected using the earlier proposed technique is explained, and the correction required for these factors as a function of individual scan line number for each detector is described. It is shown how the revised technique can be incorporated into an operational environment.

  19. A rapid chemical method for lysing Arabidopsis cells for protein analysis.

    PubMed

    Tsugama, Daisuke; Liu, Shenkui; Takano, Tetsuo

    2011-07-15

    Protein extraction is a frequent procedure in biological research. For preparation of plant cell extracts, plant materials usually have to be ground and homogenized to physically break the robust cell wall, but this step is laborious and time-consuming when a large number of samples are handled at once. We developed a chemical method for lysing Arabidopsis cells without grinding. In this method, plants are boiled for just 10 minutes in a solution containing a Ca2+ chelator and detergent. Cell extracts prepared by this method were suitable for SDS-PAGE and immunoblot analysis. This method was also applicable to genomic DNA extraction for PCR analysis. Our method was applied to many other plant species, and worked well for some of them. Our method is rapid and economical, and allows many samples to be prepared simultaneously for protein analysis. Our method is useful not only for Arabidopsis research but also research on certain other species.

  20. Rapid, Direct Fluorescent-Antibody Method for the Detection of Salmonellae in Food and Feeds

    PubMed Central

    Insalata, N. F.; Mahnke, C. W.; Dunlap, W. G.

    1972-01-01

    An improved immunofluorescent-antibody (FA) method for the detection of salmonellae in foods and feeds was developed. This FA method combines a rapid cultural phase and a serological phase that allow for propagation of salmonellae in a minimum time, employing the industrial 8-hr work day as a guide. Two hundred fifty naturally contaminated human food and animal feed samples, representing 647 trials, were tested by the FA method. A total of 18 different food and feed samples was used. The method used by the Association of Official Analytical Chemists (AOAC) for the detection of salmonellae was the control method. The percent agreement when comparing the FA slide method to the AOAC method ranged from 87.1 to 95.3%, depending upon the conjugated antisera used in comparative studies. PMID:4564047

  1. Rapid diagnostic methods for influenza virus in clinical specimens - A comparative study

    NASA Technical Reports Server (NTRS)

    Evans, A. S.; Olson, B.

    1982-01-01

    A comparison of five rapid viral diagnostic techniques for identifying influenza virus in nasopharyngeal aspirates has been made on patients with influenza-like illnesses. Initial results with immune electron microscopy were positive in only one of 11 specimens from which virus was isolated and further work abandoned. Four other rapid tests were carried out on 39 specimens from which influenza virus had been isolated in tissue culture in 28. Of these 28 specimens yielding virus, 24 (85.7 percent) were positive by an indirect fluorescent antibody test (IFAT) on nasopharyngeal cells, 18 (64.3 percent) by enzyme-linked immunosorbent assay (ELISA), 19 (67.8 percent) by enzyme-linked fluorescent assay (ELFA), and 26 (92.8 percent) by a rapid tissue culture amplification method (TCA) in a continuous Rhesus monkey kidney line (LLC-MK2) with identification of virus by fluorescent antibody. In terms of sensitivity, simplicity, and rapidity, a combination of the IFAT and TCA methods seems to be very useful.

  2. Development of a loop-mediated isothermal amplification method for rapid detection of pigeon circovirus.

    PubMed

    Tsai, Shinn Shyong; Chang, Yeng Ling; Huang, Yen Li; Liu, Hung Jen; Ke, Guan Ming; Chiou, Chwei Jang; Hsieh, Yao Ching; Chang, Tsung Chou; Cheng, Li Ting; Chuang, Kuo Pin

    2014-05-01

    There are no effective antiviral treatments for pigeon circovirus (PiCV); thus, rapid diagnosis is critical for effective control of the disease caused by this virus. The recent development of a novel LAMP technique that amplifies nucleic acids rapidly with high specificity and sensitivity under isothermal conditions has overcome some of the deficiencies of nucleic-acid-based diagnostic tests. We established a LAMP method for rapid detection of PiCV using two pairs of primers that were designed from PiCV and compared its sensitivity and specificity with that of PCR. Amplification by LAMP was optimal at 63 °C for 60 min. The detection limit was nearly 0.5 pg of PiCV DNA, making it ten times more sensitive than PCR. There was no cross-reaction with porcine circovirus type 2 (PCV2), pigeon Trichomonas gallinae, or pigeon herpesvirus (PHV) under the same conditions. The assay also successfully detected the pathogen DNA in the tissues of infected pigeons. This is the first report indicating that LAMP is a valuable, rapid method of detecting PiCV with high sensitivity and specificity.

  3. Designing an in-flight airborne calibration site using experience from vicarious radiometric satellite calibration

    NASA Astrophysics Data System (ADS)

    Livens, Stefan; Debruyn, Walter; Sterckx, Sindy; Reusen, Ils

    2011-11-01

    Laboratory calibration of electro-optical sensors is preferably complemented by regular in-flight verification. This checks whether the lab calibration parameters remain valid or recalibration is necessary. In-flight verification can be achieved by vicarious calibration using in-flight measurements of calibration targets. We intend to identify and design a set of suitable radiometric calibration targets. For this, we borrow from expertise gained with the PROBA-V satellite calibration system, which uses multiple vicarious methods relying on diverse natural on-ground targets. Besides reflectance based calibration using ground measurements, the PROBA-V calibration methods are unproven for use in airborne calibration. The selected targets should be suitable for the calibration of both multispectral and hyperspectral imagers. We start from general requirements for radiometric targets and investigate their applicability to airborne calibration. From this we identify two possible sets of natural calibration sites in Belgium. One set, located in the Campine region, contains small water bodies and sandy lakesides. Another set is located in the Westhoek region near the Belgian coast. It offers better suitable water bodies, as well as sandy areas, grass fields and dark targets. Airborne calibration lends itself to the use of smaller artifical targets. We propose to complement the natural targets with a portable target consisting of agricultural nets with different densities. The definition of sets of calibration targets, both natural and artificial can facilitate the investigation of the usability of vicarious targets and method for inflight radiometric verification.

  4. Rapid simulation of electromagnetic telemetry using an axisymmetric semianalytical finite element method

    NASA Astrophysics Data System (ADS)

    Chen, Jiefu; Zeng, Shubin; Dong, Qiuzhao; Huang, Yueqin

    2017-02-01

    An axisymmetric semianalytical finite element method is proposed and employed for rapid simulations of electromagnetic telemetry in layered underground formation. In this method, the layered media is decomposed into several subdomains and the interfaces between subdomains are discretized by conventional finite elements. Then a Riccati equation based high precision integration scheme is applied to exploit the homogeneity along the vertical direction in each layer. This semianalytical finite element scheme is very efficient in modeling electromagnetic telemetry in layered formation. Numerical examples as well as a field case with water based mud as drilling fluid are given to demonstrate the validity and effectiveness of this method.

  5. Rapid methods for testing the efficacy of sterilization-grade filter membranes.

    PubMed

    Griffiths, M H; Andrew, P W; Ball, P R; Hall, G M

    2000-08-01

    The validation of sterilization-grade membranes is integral to ensuring the efficient and safe use of microfiltration systems. Here validation refers to the production of sterile filtrate for sterilizing-grade membranes under challenge test conditions. Current validation methods require 48 h of culture for results to become available, which creates time delays within the manufacturing process and quality control (QC) backlogs. This work compares four methods for the production of filter challenge test data, to the desired test sensitivity, within 24 h using bioluminescent and fluorescent recombinant strains of the test organism Brevundimonas diminuta. These methods should provide a way to implement more rapid QC test regimens for filters.

  6. Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian K.; Warren, Richard A.; ...

    2016-03-24

    A new method that rapidly preconcentrates and measures 226Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226Ra sample preparation takes < 2 hours.

  7. Application of Rapid Prototyping Methods to High-Speed Wind Tunnel Testing

    NASA Technical Reports Server (NTRS)

    Springer, A. M.

    1998-01-01

    This study was undertaken in MSFC's 14-Inch Trisonic Wind Tunnel to determine if rapid prototyping methods could be used in the design and manufacturing of high speed wind tunnel models in direct testing applications, and if these methods would reduce model design/fabrication time and cost while providing models of high enough fidelity to provide adequate aerodynamic data, and of sufficient strength to survive the test environment. Rapid prototyping methods utilized to construct wind tunnel models in a wing-body-tail configuration were: fused deposition method using both ABS plastic and PEEK as building materials, stereolithography using the photopolymer SL-5170, selective laser sintering using glass reinforced nylon, and laminated object manufacturing using plastic reinforced with glass and 'paper'. This study revealed good agreement between the SLA model, the metal model with an FDM-ABS nose, an SLA nose, and the metal model for most operating conditions, while the FDM-ABS data diverged at higher loading conditions. Data from the initial SLS model showed poor agreement due to problems in post-processing, resulting in a different configuration. A second SLS model was tested and showed relatively good agreement. It can be concluded that rapid prototyping models show promise in preliminary aerodynamic development studies at subsonic, transonic, and supersonic speeds.

  8. Compression-based distance (CBD): a simple, rapid, and accurate method for microbiota composition comparison

    PubMed Central

    2013-01-01

    Background Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. Results We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. Conclusion CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets. PMID:23617892

  9. Compression-based distance (CBD): a simple, rapid, and accurate method for microbiota composition comparison.

    PubMed

    Yang, Fang; Chia, Nicholas; White, Bryan A; Schook, Lawrence B

    2013-04-23

    Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets.

  10. RAPID METHOD FOR PLUTONIUM, AMERICIUM AND CURIUM IN VERY LARGE SOIL SAMPLES

    SciTech Connect

    Maxwell, S

    2007-01-08

    The analysis of actinides in environmental soil and sediment samples is very important for environmental monitoring. There is a need to measure actinide isotopes with very low detection limits. A new, rapid actinide separation method has been developed and implemented that allows the measurement of plutonium, americium and curium isotopes in very large soil samples (100-200 g) with high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and DGA-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), americium (Am), and curium (Cm) using a single multistage column combined with alpha spectrometry. The method combines an acid leach step and innovative matrix removal using cerium fluoride precipitation to remove the difficult soil matrix. This method is unique in that it provides high tracer recoveries and effective removal of interferences with small extraction chromatography columns instead of large ion exchange resin columns that generate large amounts of acid waste. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized.

  11. Determination of cell wall teichoic acid structure of staphylococci by rapid chemical and serological screening methods.

    PubMed

    Endl, J; Seidl, P H; Fiedler, F; Schleifer, K H

    1984-03-01

    Investigations of cell wall teichoic acid structures of various staphylococci were carried out by a rapid method based on the gas-liquid chromatographic separation of products obtained after treatment of phenol-extracted cells with 70% hydrofluoric acid. In most of the strains teichoic acids of the poly(glycerolphosphate) and/or poly(ribitol-phosphate) type were found. Teichoic acids of the poly(glycerolphosphate-N-acetylglucosaminephosphate) type and polymers consisting of N-acetylglucosaminephosphate were present in few strains. The results obtained by the rapid chemical screening method were compared with data obtained by serological analysis of teichoic acid structures using specific antisera and the lectin wheat germ agglutinin. Teichoic acid components occurring in low concentrations could only be detected with the chemical and not with the serological method. A number of strains of species of the genus Staphylococcus have been studied using these rapid methods. With a few exceptions, the teichoic acid structure proved to be a constant marker within a given species.

  12. Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection.

    PubMed

    Niimi, Hideki; Ueno, Tomohiro; Hayashi, Shirou; Abe, Akihito; Tsurue, Takahiro; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Goto, Michihiko; Akiyama, Makoto; Yamamoto, Yoshihiro; Saito, Shigeru; Kitajima, Isao

    2015-07-28

    Acquiring the earliest possible identification of pathogenic microorganisms is critical for selecting the appropriate antimicrobial therapy in infected patients. We herein report the novel "melting temperature (Tm) mapping method" for rapidly identifying the dominant bacteria in a clinical sample from sterile sites. Employing only seven primer sets, more than 100 bacterial species can be identified. In particular, using the Difference Value, it is possible to identify samples suitable for Tm mapping identification. Moreover, this method can be used to rapidly diagnose the absence of bacteria in clinical samples. We tested the Tm mapping method using 200 whole blood samples obtained from patients with suspected sepsis, 85% (171/200) of which matched the culture results based on the detection level. A total of 130 samples were negative according to the Tm mapping method, 98% (128/130) of which were also negative based on the culture method. Meanwhile, 70 samples were positive according to the Tm mapping method, and of the 59 suitable for identification, 100% (59/59) exhibited a "match" or "broad match" with the culture or sequencing results. These findings were obtained within three hours of whole blood collection. The Tm mapping method is therefore useful for identifying infectious diseases requiring prompt treatment.

  13. Reduction of Striping Noise in Overlapping LIDAR Intensity Data by Radiometric Normalization

    NASA Astrophysics Data System (ADS)

    Yan, Wai Yeung; Shaker, Ahmed

    2016-06-01

    To serve seamless mapping, airborne LiDAR data are usually collected with multiple parallel strips with one or two cross strip(s). Nevertheless, the overlapping regions of LiDAR data strips are usually found with unbalanced intensity values, resulting in the appearance of stripping noise. Despite that physical intensity correction methods are recently proposed, some of the system and environmental parameters are assumed as constant or not disclosed, leading to such an intensity discrepancy. This paper presents a new normalization technique to adjust the radiometric misalignment found in the overlapping LiDAR data strips. The normalization technique is built upon a second-order polynomial function fitted on the joint histogram plot, which is generated with a set of pairwise closest data points identified within the overlapping region. The method was tested on Teledyne Optech's Gemini dataset (at 1064 nm wavelength), where the LiDAR intensity data were first radiometrically corrected based on the radar (range) equation. Five land cover features were selected to evaluate the coefficient of variation (cv) of the intensity values before and after implementing the proposed method. Reduction of cv was found by 19% to 59% in the Gemini dataset, where the striping noise was significantly reduced in the radiometrically corrected and normalized intensity data. The Gemini dataset was also used to conduct land cover classification, and the overall accuracy yielded a notable improvement of 9% to 18%. As a result, LiDAR intensity data should be pre-processed with radiometric correction and normalization prior to any data manipulation.

  14. Automated geographic registration and radiometric correction for UAV-based mosaics

    NASA Astrophysics Data System (ADS)

    Thomasson, J. Alex; Shi, Yeyin; Sima, Chao; Yang, Chenghai; Cope, Dale A.

    2017-05-01

    Texas A and M University has been operating a large-scale, UAV-based, agricultural remote-sensing research project since 2015. To use UAV-based images in agricultural production, many high-resolution images must be mosaicked together to create an image of an agricultural field. Two key difficulties to science-based utilization of such mosaics are geographic registration and radiometric calibration. In our current research project, image files are taken to the computer laboratory after the flight, and semi-manual pre-processing is implemented on the raw image data, including ortho-mosaicking and radiometric calibration. Ground control points (GCPs) are critical for high-quality geographic registration of images during mosaicking. Applications requiring accurate reflectance data also require radiometric-calibration references so that reflectance values of image objects can be calculated. We have developed a method for automated geographic registration and radiometric correction with targets that are installed semi-permanently at distributed locations around fields. The targets are a combination of black (≍5% reflectance), dark gray (≍20% reflectance), and light gray (≍40% reflectance) sections that provide for a transformation of pixel-value to reflectance in the dynamic range of crop fields. The exact spectral reflectance of each target is known, having been measured with a spectrophotometer. At the time of installation, each target is measured for position with a real-time kinematic GPS receiver to give its precise latitude and longitude. Automated location of the reference targets in the images is required for precise, automated, geographic registration; and automated calculation of the digital-number to reflectance transformation is required for automated radiometric calibration. To validate the system for radiometric calibration, a calibrated UAV-based image mosaic of a field was compared to a calibrated single image from a manned aircraft. Reflectance

  15. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy

    PubMed Central

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818

  16. Ultrasonic-assisted deacetylation of cellulose acetate nanofibers: A rapid method to produce cellulose nanofibers.

    PubMed

    Ahmed, Farooq; Ayoub Arbab, Alvira; Jatoi, Abdul Wahab; Khatri, Muzamil; Memon, Najma; Khatri, Zeeshan; Kim, Ick Soo

    2017-05-01

    Herein we report a rapid method for deacetylation of cellulose acetate (CA) nanofibers in order to produce cellulose nanofibers using ultrasonic energy. The CA nanofibers were fabricated via electrospinning thereby treated with NaOH and NaOH/EtOH solutions at various pH levels for 30, 60 and 90min assisted by ultrasonic energy. The nanofiber webs were optimized by degree of deacetylation (DD%) and wicking behavior. The resultant nanofibers were further characterized by FTIR, SEM, WAXD, DSC analysis. The DD% and FTIR results confirmed a complete conversion of CA nanofibers to cellulose nanofibers within 1h with substantial increase of wicking height. Nanofibers morphology under SEM showed slightly swelling and no damage of nanofibers observed by use of ultrasonic energy. The results of ultrasonic-assisted deacetylation are comparable with the conventional deacetylation. Our rapid method offers substantially reduced deacetylation time from 30h to just 1h, thanks to the ultrasonic energy.

  17. Evaluation of methods for rapid determination of freezing point of aviation fuels

    NASA Technical Reports Server (NTRS)

    Mathiprakasam, B.

    1982-01-01

    Methods for identification of the more promising concepts for the development of a portable instrument to rapidly determine the freezing point of aviation fuels are described. The evaluation process consisted of: (1) collection of information on techniques previously used for the determination of the freezing point, (2) screening and selection of these techniques for further evaluation of their suitability in a portable unit for rapid measurement, and (3) an extensive experimental evaluation of the selected techniques and a final selection of the most promising technique. Test apparatuses employing differential thermal analysis and the change in optical transparency during phase change were evaluated and tested. A technique similar to differential thermal analysis using no reference fuel was investigated. In this method, the freezing point was obtained by digitizing the data and locating the point of inflection. Results obtained using this technique compare well with those obtained elsewhere using different techniques. A conceptual design of a portable instrument incorporating this technique is presented.

  18. A modified cluster-sampling method for post-disaster rapid assessment of needs.

    PubMed Central

    Malilay, J.; Flanders, W. D.; Brogan, D.

    1996-01-01

    The cluster-sampling method can be used to conduct rapid assessment of health and other needs in communities affected by natural disasters. It is modelled on WHO's Expanded Programme on Immunization method of estimating immunization coverage, but has been modified to provide (1) estimates of the population remaining in an area, and (2) estimates of the number of people in the post-disaster area with specific needs. This approach differs from that used previously in other disasters where rapid needs assessments only estimated the proportion of the population with specific needs. We propose a modified n x k survey design to estimate the remaining population, severity of damage, the proportion and number of people with specific needs, the number of damaged or destroyed and remaining housing units, and the changes in these estimates over a period of time as part of the survey. PMID:8823962

  19. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications.

    PubMed

    Devi, Selvaraju Gayathri; Fathima, Anwar Aliya; Radha, Sudhakar; Arunraj, Rex; Curtis, Wayne R; Ramya, Mohandass

    2015-01-01

    A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely "powdered glass method" from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC) as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil) with high purity (A260/280: 1.76 ± 0.05) and reduced humic substances (A340: 0.047 ± 0.03). The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method's applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666).

  20. Development of a rapid and simple voltammetric method to determine total antioxidative capacity of edible oils.

    PubMed

    Gulaboski, Rubin; Mirčeski, Valentin; Mitrev, Saša

    2013-05-01

    In this work we report on a new, rapid and simple voltammetric method to determine the total antioxidant capacity (TAC) of the edible oils. The method explores the ABTS radical (2,2'-azinobis(3-ethylbenzothiazoline-6-sulphonic acid)) assay as a redox probe and it relays on measuring catalytic voltammetric currents. The electrocatalysis comprises redox regeneration of the electrochemically created ABTS(+) radical either by Trolox (6-hydroxy-2,5,7,8-tetramethychroman-2-carboxylic acid) or by antioxidants present in studied oils. The detection limit of the method is determined to be 0.5 mg/L of Trolox equivalent, being a slightly lower than the corresponding UV-VIS spectrophotometric method. Applying the proposed voltammetric method the total antioxidant capacity of three types of commercially available cold-pressed edible oils are determined, and the results are found to be in a very good agreement with those obtained by UV-VIS spectrophotometry. The reported voltammetric method is cheap, rapid and simple, and it can be used as a sustainable alternative to the UV-VIS methods for the determination of total antioxidant capacitance of oils and other liquid lipophilic nutrients. Potent antioxidant capacity of studied oils was also confirmed by electron paramagnetic resonance spectroscopy of superoxide anion produced by macrophages.

  1. Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

    NASA Technical Reports Server (NTRS)

    McFeters, G. A.; Pyle, B. H.; Lisle, J. T.; Broadaway, S. C.

    1999-01-01

    Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between

  2. Method for rapid base sequencing in DNA and RNA with two base labeling

    DOEpatents

    Jett, James H.; Keller, Richard A.; Martin, John C.; Posner, Richard G.; Marrone, Babetta L.; Hammond, Mark L.; Simpson, Daniel J.

    1995-01-01

    Method for rapid-base sequencing in DNA and RNA with two-base labeling and employing fluorescent detection of single molecules at two wavelengths. Bases modified to accept fluorescent labels are used to replicate a single DNA or RNA strand to be sequenced. The bases are then sequentially cleaved from the replicated strand, excited with a chosen spectrum of electromagnetic radiation, and the fluorescence from individual, tagged bases detected in the order of cleavage from the strand.

  3. A rapid method for establishment of a reverse genetics system for canine parvovirus.

    PubMed

    Yu, Yongle; Su, Jun; Wang, Jigui; Xi, Ji; Mao, Yaping; Hou, Qiang; Zhang, Xiaomei; Liu, Weiquan

    2017-08-14

    Canine parvovirus (CPV) is an important and highly prevalent pathogen of dogs that causes acute hemorrhagic enteritis disease. Here, we describe a rapid method for the construction and characterization of a full-length infectious clone (rCPV) of CPV. Feline kidney (F81) cells were transfected with rCPV incorporating an engineered EcoR I site that served as a genetic marker. The rescued virus was indistinguishable from that of wild-type virus in its biological properties.

  4. Method for rapid base sequencing in DNA and RNA with two base labeling

    DOEpatents

    Jett, J.H.; Keller, R.A.; Martin, J.C.; Posner, R.G.; Marrone, B.L.; Hammond, M.L.; Simpson, D.J.

    1995-04-11

    A method is described for rapid-base sequencing in DNA and RNA with two-base labeling and employing fluorescent detection of single molecules at two wavelengths. Bases modified to accept fluorescent labels are used to replicate a single DNA or RNA strand to be sequenced. The bases are then sequentially cleaved from the replicated strand, excited with a chosen spectrum of electromagnetic radiation, and the fluorescence from individual, tagged bases detected in the order of cleavage from the strand. 4 figures.

  5. A simple and rapid nuclear staining method for Rhizoctonia solani Kuhn.

    PubMed

    Seema, M; Punith, B D; Devaki, N S

    2012-04-01

    We developed a modified staining technique using acridine orange to stain the nuclei of Rhizoctonia solani. Acridine orange solution was prepared in acetic acid buffer, pH 7.2. Staining for 15 min was critical for observing the nuclei. All of the isolates were found to be multinucleated. The nuclei appeared bright green with light orange background. This method is simple, rapid and reproducible.

  6. Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

    NASA Technical Reports Server (NTRS)

    McFeters, G. A.; Pyle, B. H.; Lisle, J. T.; Broadaway, S. C.

    1999-01-01

    Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between

  7. Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection

    PubMed Central

    Niimi, Hideki; Ueno, Tomohiro; Hayashi, Shirou; Abe, Akihito; Tsurue, Takahiro; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Goto, Michihiko; Akiyama, Makoto; Yamamoto, Yoshihiro; Saito, Shigeru; Kitajima, Isao

    2015-01-01

    Acquiring the earliest possible identification of pathogenic microorganisms is critical for selecting the appropriate antimicrobial therapy in infected patients. We herein report the novel “melting temperature (Tm) mapping method” for rapidly identifying the dominant bacteria in a clinical sample from sterile sites. Employing only seven primer sets, more than 100 bacterial species can be identified. In particular, using the Difference Value, it is possible to identify samples suitable for Tm mapping identification. Moreover, this method can be used to rapidly diagnose the absence of bacteria in clinical samples. We tested the Tm mapping method using 200 whole blood samples obtained from patients with suspected sepsis, 85% (171/200) of which matched the culture results based on the detection level. A total of 130 samples were negative according to the Tm mapping method, 98% (128/130) of which were also negative based on the culture method. Meanwhile, 70 samples were positive according to the Tm mapping method, and of the 59 suitable for identification, 100% (59/59) exhibited a “match” or “broad match” with the culture or sequencing results. These findings were obtained within three hours of whole blood collection. The Tm mapping method is therefore useful for identifying infectious diseases requiring prompt treatment. PMID:26218169

  8. An Innovative Method for Rapid Identification and Detection of Vibrio alginolyticus in Different Infection Models

    PubMed Central

    Fu, Kaifei; Li, Jun; Wang, Yuxiao; Liu, Jianfei; Yan, He; Shi, Lei; Zhou, Lijun

    2016-01-01

    Vibrio alginolyticus is one of the most common pathogenic marine Vibrio species, and has been found to cause serious seafood-poisoning or fatal extra-intestinal infections in humans, such as necrotizing soft-tissue infections, bacteremia, septic shock, and multiple organ failures. Delayed accurate diagnosis and treatment of most Vibrio infections usually result to high mortality rates. The objective of this study was to establish a rapid diagnostic method to detect and identify the presence of V. alginolyticus in different samples, so as to facilitate timely treatment. The widely employed conventional methods for detection of V. alginolyticus include biochemical identification and a variety of PCR methods. The former is of low specificity and time-consuming (2–3 days), while the latter has improved accuracy and processing time. Despite such advancements, these methods are still complicated, time-consuming, expensive, require expertise and advanced laboratory systems, and are not optimal for field use. With the goal of providing a simple and efficient way to detect V. alginolyticus, we established a rapid diagnostic method based on loop-mediated Isothermal amplification (LAMP) technology that is feasible to use in both experimental and field environments. Three primer pairs targeting the toxR gene of V. alginolyticus were designed, and amplification was carried out in an ESE tube scanner and Real-Time PCR device. We successfully identified 93 V. alginolyticus strains from a total of 105 different bacterial isolates and confirmed their identity by 16s rDNA sequencing. We also applied this method on infected mouse blood and contaminated scallop samples, and accurate results were both easily and rapidly (20–60 min) obtained. Therefore, the RT-LAMP assay we developed can be conveniently used to detect the presence of V. alginolyticus in different samples. Furthermore, this method will also fulfill the gap for real-time screening of V. alginolyticus infections

  9. Rapid method to detect duplex formation in sequencing by hybridization methods

    DOEpatents

    Mirzabekov, A.D.; Timofeev, E.N.; Florentiev, V.L.; Kirillov, E.V.

    1999-01-19

    A method for determining the existence of duplexes of oligonucleotide complementary molecules is provided. A plurality of immobilized oligonucleotide molecules, each of a specific length and each having a specific base sequence, is contacted with complementary, single stranded oligonucleotide molecules to form a duplex. Each duplex facilitates intercalation of a fluorescent dye between the base planes of the duplex. The invention also provides for a method for constructing oligonucleotide matrices comprising confining light sensitive fluid to a surface and exposing the light-sensitive fluid to a light pattern. This causes the fluid exposed to the light to coalesce into discrete units and adhere to the surface. This places each of the units in contact with a set of different oligonucleotide molecules so as to allow the molecules to disperse into the units. 13 figs.

  10. Rapid method to detect duplex formation in sequencing by hybridization methods

    DOEpatents

    Mirzabekov, Andrei Darievich; Timofeev, Edward Nikolaevich; Florentiev, Vladimer Leonidovich; Kirillov, Eugene Vladislavovich

    1999-01-01

    A method for determining the existence of duplexes of oligonucleotide complementary molecules is provided whereby a plurality of immobilized oligonucleotide molecules, each of a specific length and each having a specific base sequence, is contacted with complementary, single stranded oligonucleotide molecules to form a duplex so as to facilitate intercalation of a fluorescent dye between the base planes of the duplex. The invention also provides for a method for constructing oligonucleotide matrices comprising confining light sensitive fluid to a surface, exposing said light-sensitive fluid to a light pattern so as to cause the fluid exposed to the light to coalesce into discrete units and adhere to the surface; and contacting each of the units with a set of different oligonucleotide molecules so as to allow the molecules to disperse into the units.

  11. Rapid method to determine 89Sr/90Sr in large concrete samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; ...

    2016-03-24

    Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g-1. The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90Sr from 5-10 g concrete samples. When, the 89Sr/90Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90Sr measured, and then 90Sr determined via 90Y separated after amore » period of ingrowth. Another approach allows the immediate determination of 90Sr in 10 g concrete aliquots without waiting for 90Y ingrowth, in instances where the shorter lived 89Sr is unlikely to be encountered.« less

  12. A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

    PubMed

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-10-02

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4min, and the separation was observed in 25s. The limit of detection (LOD) was 4.0nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification.

  13. GSMA: Gene Set Matrix Analysis, An Automated Method for Rapid Hypothesis Testing of Gene Expression Data

    PubMed Central

    Cheadle, Chris; Watkins, Tonya; Fan, Jinshui; Williams, Marc A.; Georas, Steven; Hall, John; Rosen, Antony; Barnes, Kathleen C.

    2007-01-01

    Background: Microarray technology has become highly valuable for identifying complex global changes in gene expression patterns. The assignment of functional information to these complex patterns remains a challenging task in effectively interpreting data and correlating results from across experiments, projects and laboratories. Methods which allow the rapid and robust evaluation of multiple functional hypotheses increase the power of individual researchers to data mine gene expression data more efficiently. Results: We have developed (gene set matrix analysis) GSMA as a useful method for the rapid testing of group-wise up- or down-regulation of gene expression simultaneously for multiple lists of genes (gene sets) against entire distributions of gene expression changes (datasets) for single or multiple experiments. The utility of GSMA lies in its flexibility to rapidly poll gene sets related by known biological function or as designated solely by the end-user against large numbers of datasets simultaneously. Conclusions: GSMA provides a simple and straightforward method for hypothesis testing in which genes are tested by groups across multiple datasets for patterns of expression enrichment. PMID:20066124

  14. A Direct and Rapid Method to Determine Cyanide in Urine by Capillary Electrophoresis

    PubMed Central

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-01-01

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4 minutes, and the separation was observed in 25 s. The limit of detection (LOD) was 4.0 nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification. PMID:26342870

  15. A Study on Optimal Strategy in Relative Radiometric Calibration for Optical Sensors

    PubMed Central

    Yu, Kai; Liu, Suhong; Zhao, Yongchao

    2017-01-01

    Based on the analysis of three main factors involved in the relative radiometric calibration for optical sensors, namely: the number of radiance level; the number of measurements at each level; and the radiance level grouping method, an optimal strategy is presented in this paper for relative radiometric calibration. First, the maximization to the possible extent of either the number of the radiance level or the number of measurements at each level can improve the precision of the calibration results, where the recommended number of measurements is no less than 20. Second, when the number of the radiance level is divisible by four, dividing all the levels evenly into four groups by intensity gradient order and conducting averages for each group could achieve calibration results with the highest precision, which is higher than the result of no grouping or any other grouping method with the mean square error being 22Mn/IT (where Mn is the mean square error of noise in the calibration data, I is the number of the radiance level, and T is the number of measurements for each level. In this case, the first two factors had an equivalent effect and showed their strongest effect on the precision. Third, when the calibration data were not evenly divided, the number of measurements demonstrated a stronger effect than the number of the radiance level. These cognitions are helping to achieve more precise relative radiometric calibration of optical sensors. PMID:28257083

  16. Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol. 2

    SciTech Connect

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines. In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios.

  17. A Microfluidic Channel Method for Rapid Drug-Susceptibility Testing of Pseudomonas aeruginosa.

    PubMed

    Matsumoto, Yoshimi; Sakakihara, Shouichi; Grushnikov, Andrey; Kikuchi, Kazuma; Noji, Hiroyuki; Yamaguchi, Akihito; Iino, Ryota; Yagi, Yasushi; Nishino, Kunihiko

    2016-01-01

    The recent global increase in the prevalence of antibiotic-resistant bacteria and lack of development of new therapeutic agents emphasize the importance of selecting appropriate antimicrobials for the treatment of infections. However, to date, the development of completely accelerated drug susceptibility testing methods has not been achieved despite the availability of a rapid identification method. We proposed an innovative rapid method for drug susceptibility testing for Pseudomonas aeruginosa that provides results within 3 h. The drug susceptibility testing microfluidic (DSTM) device was prepared using soft lithography. It consisted of five sets of four microfluidic channels sharing one inlet slot, and the four channels are gathered in a small area, permitting simultaneous microscopic observation. Antimicrobials were pre-introduced into each channel and dried before use. Bacterial suspensions in cation-adjusted Mueller-Hinton broth were introduced from the inlet slot and incubated for 3 h. Susceptibilities were microscopically evaluated on the basis of differences in cell numbers and shapes between drug-treated and control cells, using dedicated software. The results of 101 clinically isolated strains of P. aeruginosa obtained using the DSTM method strongly correlated with results obtained using the ordinary microbroth dilution method. Ciprofloxacin, meropenem, ceftazidime, and piperacillin caused elongation in susceptible cells, while meropenem also induced spheroplast and bulge formation. Morphological observation could alternatively be used to determine the susceptibility of P. aeruginosa to these drugs, although amikacin had little effect on cell shape. The rapid determination of bacterial drug susceptibility using the DSTM method could also be applicable to other pathogenic species, and it could easily be introduced into clinical laboratories without the need for expensive instrumentation.

  18. High accuracy in situ radiometric mapping.

    PubMed

    Tyler, Andrew N

    2004-01-01

    In situ and airborne gamma ray spectrometry have been shown to provide rapid and spatially representative estimates of environmental radioactivity across a range of landscapes. However, one of the principal limitations of this technique has been the influence of changes in the vertical distribution of the source (e.g. 137Cs) on the observed photon fluence resulting in a significant reduction in the accuracy of the in situ activity measurement. A flexible approach for single gamma photon emitting radionuclides is presented, which relies on the quantification of forward scattering (or valley region between the full energy peak and Compton edge) within the gamma ray spectrum to compensate for changes in the 137Cs vertical activity distribution. This novel in situ method lends itself to the mapping of activity concentrations in environments that exhibit systematic changes in the vertical activity distribution. The robustness of this approach has been demonstrated in a salt marsh environment on the Solway coast, SW Scotland, with both a 7.6 cm x 7.6 cm NaI(Tl) detector and a 35% n-type HPGe detector. Application to ploughed field environments has also been demonstrated using HPGe detector, including its application to the estimation of field moist bulk density and soil erosion measurement. Ongoing research work is also outlined.

  19. A method of rapidly estimating the position of the laminar separation point

    NASA Technical Reports Server (NTRS)

    Von Doenhoff, Albert E

    1938-01-01

    A method is described of rapidly estimating the position of the laminar separation point from the given pressure distribution along a body; the method is applicable to a fairly wide variety of cases. The laminar separation point is found by the von Karman-Millikan method for a series of velocity distributions along a flat plate, which consist of a region of uniform velocity followed by a region of uniform decreased velocity. It is shown that such a velocity distribution can frequently replace the actual velocity distribution along a body insofar as the effects on laminar separation are concerned. An example of the application of the method is given by using it to calculate the position of the laminar separation point on the NACA 0012 airfoil section at zero lift. The agreement between the position of the separation point calculated according to the present method and that found from more elaborate computations is very good.

  20. Validation of a screening method for rapid control of macrocyclic lactone mycotoxins in maize flour samples.

    PubMed

    Zougagh, Mohammed; Téllez, Helena; Sánchez, Alberto; Chicharro, Manuel; Ríos, Angel

    2008-05-01

    A procedure for the analytical validation of a rapid supercritical fluid extraction amperometric screening method for controlling macrocyclic lactone mycotoxins in maize flour samples has been developed. The limit established by European legislation (0.2 mg kg(-1)), in reference to zearalenone (ZON) mycotoxin, was taken as the reference threshold to validate the proposed method. Natural ZON metabolites were also included in this study to characterize the final screening method. The objective was the reliable classification of samples as positive or negative samples. The cut-off level was fixed at a global concentration of mycotoxins of 0.17 mg kg(-1). An expanded unreliability zone between 0.16 and 0.23 mg kg(-1) characterized the screening method for classifying the samples. A set of 30 samples was used for the final demonstration of the reliability and usefulness of the method.

  1. Multifrequency excitation method for rapid and accurate dynamic test of micromachined gyroscope chips.

    PubMed

    Deng, Yan; Zhou, Bin; Xing, Chao; Zhang, Rong

    2014-10-17

    A novel multifrequency excitation (MFE) method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE) method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  2. Simple and rapid method for the analysis of phenolic compounds in beverages and grains.

    PubMed

    Medina, Marjorie B

    2011-03-09

    A new method for the detection of phenolics in food systems was developed. This method is based on interactions of phenolics with Fast Blue BB diazonium salt in alkali pH, forming azo complexes, with the absorbance measured at 420 nm after 60 min. The linear regression correlations (R(2)) of gallic acid calibration standards were >0.99. The phenolic content (gallic acid equivalent) of samples analyzed yielded higher ratios (1.7-6.6) of the total phenolics by Fast Blue BB to Folin-Ciocalteu methods in most beverages and grain samples, but in flaxseed and some juice blends, the ratios were <1. The lower ratios suggest the presence of non-phenolic reducing constituents measured with the Folin-Ciocalteu method as "total phenolics". This method is simple and inexpensive and can be used to rapidly assess the total phenolics of foods and beverages.

  3. Rapid air titration method for determining SO/sub 2/ concentration in inhalation chambers

    SciTech Connect

    Snyder, E.A.; Palmes, E.D.

    1985-06-01

    A rapid air titration method for determining SO/sub 2/ concentration in inhalation chambers has been validated using the pararosaniline-formaldehyde (PRA) method of West and Gaeke. This air-titration (iodate) method is an adaptation of iodometric methods using a starch indicator. Potassium iodate and an excess of potassium iodide are used in the reaction. Sampling is completed in ten minutes or less and concentration is calculated by use of a simple formula. Linear equations were derived over the range of concentrations from 0.5 to 100 ppm SO/sub 2/ for uncorrected iodate bubbler results, data corrected for tandem bubbler concentrations and data corrected for mean iodate bubbler efficiency. Linear correlation with the PRA method over this range was 0.999 for all three sets of data.

  4. Resazurin tube method: rapid, simple, and inexpensive method for detection of drug resistance in the clinical isolates of mycobacterium tuberculosis.

    PubMed

    Patil, Santosh S; Mohite, Shivajirao T; Kulkarni, Sunanda A; Udgaonkar, Usha S

    2014-10-01

    Tuberculosis (TB) remains a serious public health problem worldwide. The emergence of drug resistance and multidrug resistance (MDR) has become the main threat to TB treatment and control programs. Rapid detection is critical for the effective treatment of patients. In recent times, a new method using the colorimetric indicator resazurin has been proposed for drug susceptibility of Mycobacterium tuberculosis. In this study, the resazurin reduction assay was adapted to screw cap tubes. Using the Resazurin Tube Method (RTM), a total of 100 clinical isolates were tested against Rifampicin (RIF) and Isoniazide (INH). By visual reading, the minimum inhibitory concentrations (MICs) were obtained after eight days. The results obtained were compared with the gold standard proportion method. Excellent results were obtained for RTM with a sensitivity of 100% for both RIF and INH, with a specificity of 98.7 and 95.3%, respectively. Kappa is the measure of agreement between the RTM and proportion method (PM) for RIF and INH, which was found to be 0.972 and 0.935 for RIF and INH, respectively. The RTM appears to be a reliable method for the rapid and simultaneous detection of MDR-TB and drug susceptibility testing (DST) of M. tuberculosis. It is simple, inexpensive, and with no biohazard risk involved.

  5. An Empirical Approach to Ocean Color Data: Reducing Bias and the Need for Post-Launch Radiometric Re-Calibration

    NASA Technical Reports Server (NTRS)

    Gregg, Watson W.; Casey, Nancy W.; O'Reilly, John E.; Esaias, Wayne E.

    2009-01-01

    A new empirical approach is developed for ocean color remote sensing. Called the Empirical Satellite Radiance-In situ Data (ESRID) algorithm, the approach uses relationships between satellite water-leaving radiances and in situ data after full processing, i.e., at Level-3, to improve estimates of surface variables while relaxing requirements on post-launch radiometric re-calibration. The approach is evaluated using SeaWiFS chlorophyll, which is the longest time series of the most widely used ocean color geophysical product. The results suggest that ESRID 1) drastically reduces the bias of ocean chlorophyll, most impressively in coastal regions, 2) modestly improves the uncertainty, and 3) reduces the sensitivity of global annual median chlorophyll to changes in radiometric re-calibration. Simulated calibration errors of 1% or less produce small changes in global median chlorophyll (less than 2.7%). In contrast, the standard NASA algorithm set is highly sensitive to radiometric calibration: similar 1% calibration errors produce changes in global median chlorophyll up to nearly 25%. We show that 0.1% radiometric calibration error (about 1% in water-leaving radiance) is needed to prevent radiometric calibration errors from changing global annual median chlorophyll more than the maximum interannual variability observed in the SeaWiFS 9-year record (+/- 3%), using the standard method. This is much more stringent than the goal for SeaWiFS of 5% uncertainty for water leaving radiance. The results suggest ocean color programs might consider less emphasis of expensive efforts to improve post-launch radiometric re-calibration in favor of increased efforts to characterize in situ observations of ocean surface geophysical products. Although the results here are focused on chlorophyll, in principle the approach described by ESRID can be applied to any surface variable potentially observable by visible remote sensing.

  6. Comparison of concentration methods for rapid detection of hookworm ova in wastewater matrices using quantitative PCR.

    PubMed

    Gyawali, P; Ahmed, W; Jagals, P; Sidhu, J P S; Toze, S

    2015-12-01

    Hookworm infection contributes around 700 million infections worldwide especially in developing nations due to increased use of wastewater for crop production. The effective recovery of hookworm ova from wastewater matrices is difficult due to their low concentrations and heterogeneous distribution. In this study, we compared the recovery rates of (i) four rapid hookworm ova concentration methods from municipal wastewater, and (ii) two concentration methods from sludge samples. Ancylostoma caninum ova were used as surrogate for human hookworm (Ancylostoma duodenale and Necator americanus). Known concentration of A. caninum hookworm ova were seeded into wastewater (treated and raw) and sludge samples collected from two wastewater treatment plants (WWTPs) in Brisbane and Perth, Australia. The A. caninum ova were concentrated from treated and raw wastewater samples using centrifugation (Method A), hollow fiber ultrafiltration (HFUF) (Method B), filtration (Method C) and flotation (Method D) methods. For sludge samples, flotation (Method E) and direct DNA extraction (Method F) methods were used. Among the four methods tested, filtration (Method C) method was able to recover higher concentrations of A. caninum ova consistently from treated wastewater (39-50%) and raw wastewater (7.1-12%) samples collected from both WWTPs. The remaining methods (Methods A, B and D) yielded variable recovery rate ranging from 0.2 to 40% for treated and raw wastewater samples. The recovery rates for sludge samples were poor (0.02-4.7), although, Method F (direct DNA extraction) provided 1-2 orders of magnitude higher recovery rate than Method E (flotation). Based on our results it can be concluded that the recovery rates of hookworm ova from wastewater matrices, especially sludge samples, can be poor and highly variable. Therefore, choice of concentration method is vital for the sensitive detection of hookworm ova in wastewater matrices. Crown Copyright © 2015. Published by Elsevier

  7. Polymerase Chain Reaction/Rapid Methods Are Gaining a Foothold in Developing Countries.

    PubMed

    Ragheb, Suzan Mohammed; Jimenez, Luis

    Detection of microbial contamination in pharmaceutical raw materials and finished products is a critical factor to guarantee their safety, stability, and potency. Rapid microbiological methods-such as polymerase chain reaction-have been widely applied to clinical and food quality control analysis. However, polymerase chain reaction applications to pharmaceutical quality control have been rather slow and sporadic. Successful implementation of these methods in pharmaceutical companies in developing countries requires important considerations to provide sensitive and robust assays that will comply with good manufacturing practices.

  8. Rapid method for protein quantitation by Bradford assay after elimination of the interference of polysorbate 80.

    PubMed

    Cheng, Yongfeng; Wei, Haiming; Sun, Rui; Tian, Zhigang; Zheng, Xiaodong

    2016-02-01

    Bradford assay is one of the most common methods for measuring protein concentrations. However, some pharmaceutical excipients, such as detergents, interfere with Bradford assay even at low concentrations. Protein precipitation can be used to overcome sample incompatibility with protein quantitation. But the rate of protein recovery caused by acetone precipitation is only about 70%. In this study, we found that sucrose not only could increase the rate of protein recovery after 1 h acetone precipitation, but also did not interfere with Bradford assay. So we developed a method for rapid protein quantitation in protein drugs even if they contained interfering substances. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Critical-Point Drying: Rapid Method for the Determination of Bacterial Extracellular Polymer and Surface Structures

    PubMed Central

    Cagle, Gerald D.

    1974-01-01

    The relative amount of extracellular polymer which remains about Azotobacter vinelandii, Zoogloea ramigera, Klebsiella pneumoniae, and Diplococcus pneumoniae after critical-point drying was studied by electron microscopy. The results obtained with this technique are compared to those obtained with methods that illustrate extracellular polymer, such as freeze-etching and ruthenium red staining. Comparative results indicate critical-point drying to be a rapid, reliable method for the determination of capsule-like polymer surrounding bacterial cells. In addition, critical-point drying can be used to observe morphogenetic changes, such as vesicle production. Images PMID:4136617

  10. Lactate UV-system: a rapid method for diagnosis of septic arthritis.

    PubMed Central

    Behn, A R; Mathews, J A; Phillips, I

    1981-01-01

    The concentration of lactic acid in synovial fluid was estimated in 43 specimens from patients with an acute monoarthritis by a simple enzyme method. In 9 patients with 10 episodes of septic arthritis concentrations of synovial fluid lactic acid were significantly higher (mean 10.8 mmol/l) than in 33 patients with nonseptic effusions (mean 3.1 mmol/l). With this method concentrations of synovial fluid lactic acid provide a rapid diagnostic guide in the separation of septic from nonseptic arthritis. PMID:7305472

  11. A rapid method for the computation of equilibrium chemical composition of air to 15000 K

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.; Erickson, Wayne D.

    1988-01-01

    A rapid computational method has been developed to determine the chemical composition of equilibrium air to 15000 K. Eleven chemically reacting species, i.e., O2, N2, O, NO, N, NO+, e-, N+, O+, Ar, and Ar+ are included. The method involves combining algebraically seven nonlinear equilibrium equations and four linear elemental mass balance and charge neutrality equations. Computational speeds for determining the equilibrium chemical composition are significantly faster than the often used free energy minimization procedure. Data are also included from which the thermodynamic properties of air can be computed. A listing of the computer program together with a set of sample results are included.

  12. Isolation of four ecdysones from Ajuga iva roots and a rapid semiquantitative method for ecdysone determination.

    PubMed

    Sabri, N N; Asaad, A; Khafagy, S M

    1981-07-01

    The ethereal extract of AJUGA IVA (L.) S CHREB. roots, yielded 4 ecdysones. Three were proved to be cyasterone, makisterone A and ecdysterone, by using UV, IR, MS spectral methods and comparison with standard samples. Spectral data indicate that the fourth ecdysone is similar to cyasterone but having an additional hydroxy group in the side-chain. The chromatographic pattern of ecdysone content in roots, stems and leaves is presented as well as a rapid and simple Semiquantitative method for their estimation. The roots had the highest total content (0.381%).

  13. A new multigroup method for cross-sections that vary rapidly in energy

    SciTech Connect

    Haut, Terry Scot; Ahrens, Cory D.; Jonko, Alexandra; Lowrie, Robert B.; Till, Andrew

    2016-11-04

    Here, we present a numerical method for solving the time-independent thermal radiative transfer (TRT) equation or the neutron transport (NT) equation when the opacity (cross-section) varies rapidly in frequency (energy) on the microscale ε; ε corresponds to the characteristic spacing between absorption lines or resonances, and is much smaller than the macroscopic frequency (energy) variation of interest. The approach is based on a rigorous homogenization of the TRT/NT equation in the frequency (energy) variable. Discretization of the homogenized TRT/NT equation results in a multigroup-type system, and can therefore be solved by standard methods.

  14. Landsat: radiometric and topographic correction of satellite imagery (R package)

    USDA-ARS?s Scientific Manuscript database

    Most Geographic Information System software includes routines for atmospheric and topograhic correction of satellite imagery such as that taken by Landsat. Radiometric correction is an active area of research, and new, improved methods are rarely if ever available for testing and application. The R...

  15. Transpulmonary hypothermia: a novel method of rapid brain cooling through augmented heat extraction from the lungs.

    PubMed

    Kumar, Matthew M; Goldberg, Andrew D; Kashiouris, Markos; Keenan, Lawrence R; Rabinstein, Alejandro A; Afessa, Bekele; Johnson, Larry D; Atkinson, John L D; Nayagam, Vedha

    2014-10-01

    Delay in instituting neuroprotective measures after cardiac arrest increases death and decreases neuronal recovery. Current hypothermia methods are slow, ineffective, unreliable, or highly invasive. We report the feasibility of rapid hypothermia induction in swine through augmented heat extraction from the lungs. Twenty-four domestic crossbred pigs (weight, 50-55kg) were ventilated with room air. Intraparenchymal brain temperature and core temperatures from pulmonary artery, lower esophagus, bladder, rectum, nasopharynx, and tympanum were recorded. In eight animals, ventilation was switched to cooled helium-oxygen mixture (heliox) and perfluorocarbon (PFC) aerosol and continued for 90min or until target brain temperature of 32°C was reached. Eight animals received body-surface cooling with water-circulating blankets; eight control animals continued to be ventilated with room air. Brain and core temperatures declined rapidly with cooled heliox-PFC ventilation. The brain reached target temperature within the study period (mean [SD], 66 [7.6]min) in only the transpulmonary cooling group. Cardiopulmonary functions and poststudy histopathological examination of the lungs were normal. Transpulmonary cooling is novel, rapid, minimally invasive, and an effective technique to induce therapeutic hypothermia. High thermal conductivity of helium and vaporization of PFC produces rapid cooling of alveolar gases. The thinness and large surface area of alveolar membrane facilitate rapid cooling of the pulmonary circulation. Because of differences in thermogenesis, blood flow, insulation, and exposure to the external environment, the brain cools at a different rate than other organs. Transpulmonary hypothermia was significantly faster than body surface cooling in reaching target brain temperature. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Membrane chromatographic immunoassay method for rapid quantitative analysis of specific serum antibodies.

    PubMed

    Ghosh, Raja

    2006-02-05

    This paper discusses a membrane chromatographic immunoassay method for rapid detection and quantitative analysis of specific serum antibodies. A type of polyvinylidine fluoride (PVDF) microfiltration membrane was used in the method for its ability to reversibly and specifically bind IgG antibodies from antiserum samples by hydrophobic interaction. Using this form of selective antibody binding and enrichment an affinity membrane with antigen binding ability was obtained in-situ. This was done by passing a pulse of diluted antiserum sample through a stack of microporous PVDF membranes. The affinity membrane thus formed was challenged with a pulse of antigen solution and the amount of antigen bound was accurately determined using chromatographic methods. The antigen binding correlated well with the antibody loading on the membrane. This method is direct, rapid and accurate, does not involve any chemical reaction, and uses very few reagents. Moreover, the same membrane could be repeatedly used for sequential immunoassays on account of the reversible nature of the antibody binding. Proof of concept of this method is provided using human hemoglobin as model antigen and rabbit antiserum against human hemoglobin as the antibody source.

  17. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications

    PubMed Central

    Devi, Selvaraju Gayathri; Fathima, Anwar Aliya; Radha, Sudhakar; Arunraj, Rex; Curtis, Wayne R.; Ramya, Mohandass

    2015-01-01

    A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely “powdered glass method” from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC) as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil) with high purity (A260/280: 1.76 ± 0.05) and reduced humic substances (A340: 0.047 ± 0.03). The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method’s applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666). PMID:26167854

  18. An evaporation study for phthalic acids--a rapid method for pharmaceutical characterization.

    PubMed

    Chatterjee, Koustuv; Hazra, Anasuya; Dollimore, David; Alexander, Kenneth S

    2002-04-01

    The objective of this study was to develop and analyze an analytical method in order to evaluate preformulation candidates by their thermodynamic parameters and evaporation characteristics. Ortho, meta and tere-phthalic acids were chosen as model compounds. The relative advantages and disadvantages of a rapid thermogravimetric method have been studied in detail, which would aid in the preformulation characterization for pharmaceuticals. Methyl paraben was taken as the model compound for calibration, as its evaporation characteristics are well known. Using the Antoine and the Langmuir equation for evaporation conjointly, the parameter k, known as the coefficient of evaporation was determined. The value for this constant was validated by three methods simultaneously. Previously the use of such methods for compounds having uninhibited zero order evaporation has been documented. In the present study, phthalic acid was chosen as the model compound since its evaporation is a two-step overlapping phenomenon. In this study we have shown the use of Pressure Differential Scanning Calorimetry in separating such simultaneous endothermic processes. The Clausius-Clapeyron equation seemingly has anomalous behavior for vapor pressure over high temperature ranges. In this study a modification of the equation has been suggested to take into account the changes in the heat capacities that result due to high temperature effects. This study aims at documenting a concise method for rapid pharmaceutical characterization and suggests modifications for some basic thermodynamic parameters over higher temperature ranges.

  19. Rapid methods to detect organic mercury and total selenium in biological samples

    PubMed Central

    2011-01-01

    Background Organic mercury (Hg) is a global pollutant of concern and selenium is believed to afford protection against mercury risk though few approaches exist to rapidly assess both chemicals in biological samples. Here, micro-scale and rapid methods to detect organic mercury (< 1.5 ml total sample volume, < 1.5 hour) and total selenium (Se; < 3.0 ml total volume, < 3 hour) from a range of biological samples (10-50 mg) are described. Results For organic Hg, samples are digested using Tris-HCl buffer (with sequential additions of protease, NaOH, cysteine, CuSO4, acidic NaBr) followed by extraction with toluene and Na2S2O3. The final product is analyzed via commercially available direct/total mercury analyzers. For Se, a fluorometric assay has been developed for microplate readers that involves digestion (HNO3-HClO4 and HCl), conjugation (2,3-diaminonaphthalene), and cyclohexane extraction. Recovery of organic Hg (86-107%) and Se (85-121%) were determined through use of Standard Reference Materials and lemon shark kidney tissues. Conclusions The approaches outlined provide an easy, rapid, reproducible, and cost-effective platform for monitoring organic Hg and total Se in biological samples. Owing to the importance of organic Hg and Se in the pathophysiology of Hg, integration of such methods into established research monitoring efforts (that largely focus on screening total Hg only) will help increase understanding of Hg's true risks. PMID:21232132

  20. Radiometric validation of NASA's Ames Research Center's Sensor Calibration Laboratory.

    PubMed

    Brown, Steven W; Johnson, B Carol; Biggar, Stuart F; Zalewski, Edward F; Cooper, John; Hajek, Pavel; Hildum, Edward; Grant, Patrick; Barnes, Robert A; Butler, James J

    2005-10-20

    The National Aeronautics and Space Administration's (NASA's) Ames Research Center's Airborne Sensor Facility (ASF) is responsible for the calibration of several airborne Earth-viewing sensor systems in support of NASA Earth Observing System (EOS) investigations. The primary artifact used to calibrate these sensors in the reflective solar region from 400 to 2500 nm is a lamp-illuminated integrating sphere source. In September 1999, a measurement comparison was made at the Ames ASF Sensor Calibration Facility to validate the radiometric scale, establish the uncertainties assigned to the radiance of this source, and examine its day-to-day repeatability. The comparison was one of a series of validation activities overseen by the EOS Calibration Program to ensure the radiometric calibration accuracy of sensors used in long-term, global, remote-sensing studies. Results of the comparison, including an evaluation of the Ames Sensor Calibration Laboratory (SCL) measurement procedures and assigned radiometric uncertainties, provide a validation of their radiometric scale at the time of the comparison. Additionally, the maintenance of the radiance scale was evaluated by use of independent, long-term, multiyear radiance validation measurements of the Ames sphere source. This series of measurements provided an independent assessment of the radiance values assigned to integrating sphere sources by the Ames SCF. Together, the measurements validate the SCF radiometric scale and assigned uncertainties over the time period from September 1999 through July 2003.

  1. Radiometric validation of NASA's Ames Research Center's Sensor Calibration Laboratory

    SciTech Connect

    Brown, Steven W.; Johnson, B. Carol; Biggar, Stuart F.; Zalewski, Edward F.; Cooper, John; Hajek, Pavel; Hildum, Edward; Grant, Patrick; Barnes, Robert A.; Butler, James J

    2005-10-20

    The National Aeronautics and Space Administration's (NASA's) Ames Research Center's Airborne Sensor Facility (ASF) is responsible for the calibration of several airborne Earth-viewing sensor systems in support of NASA Earth Observing System (EOS) investigations. The primary artifact used to calibrate these sensors in the reflective solar region from 400 to 2500 nm is a lamp-illuminated integrating sphere source. In September 1999, a measurement comparison was made at the Ames ASF Sensor Calibration Facility to validate the radiometric scale, establish the uncertainties assigned to the radiance of this source, and examine its day-to-day repeatability. The comparison was one of a series of validation activities overseen by the EOS Calibration Program to ensure the radiometric calibration accuracy of sensors used in long-term, global, remote-sensing studies. Results of the comparison, including an evaluation of the Ames Sensor Calibration Laboratory (SCL) measurement procedures and assigned radiometric uncertainties, provide a validation of their radiometric scale at the time of the comparison. Additionally, the maintenance of the radiance scale was evaluated by use of independent, long-term, multiyear radiance validation measurements of the Ames sphere source. This series of measurements provided an independent assessment of the radiance values assigned to integrating sphere sources by the Ames SCF. Together, the measurements validate the SCF radiometric scale and assigned uncertainties over the time period from September 1999 through July 2003.

  2. Application of rapid cloud point extraction method for trace cobalt analysis coupled with spectrophotometric determination.

    PubMed

    Wen, Xiaodong; He, Lei; Shi, Chunsheng; Deng, Qingwen; Wang, Jiwei; Zhao, Xia

    2013-11-01

    In this work, the analytical performance of conventional spectrophotometer was improved through the coupling of effective preconcentration method with spectrophotometric determination. Rapidly synergistic cloud point extraction (RS-CPE) was used to pre-concentrate ultra trace cobalt and firstly coupled with spectrophotometric determination. The developed coupling was simple, rapid and efficient. The factors influencing RS-CPE and spectrophotometer were optimized. Under the optimal conditions, the limit of detection (LOD) was 0.6μgL(-1), with sensitivity enhancement factor of 23. The relative standard deviation (RSD) for seven replicate measurements of 50μgL(-1) of cobalt was 4.3%. The recoveries for the spiked samples were in the acceptable range of 93.8-105%. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    USGS Publications Warehouse

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  4. Analysis Of Volatile Fingerprints: A Rapid Screening Method For Antifungal Agents For Efficacy Against Dermatophytes

    NASA Astrophysics Data System (ADS)

    Naraghi, Kamran; Sahgal, Natasha; Adriaans, Beverley; Barr, Hugh; Magan, Naresh

    2009-05-01

    The potential of using an electronic nose (E. nose) for rapid screening dermatophytes to antifungal agents was studied. In vitro, the 50 and 90% effective concentration (EC) values of five antifungal agents for T. rubrum and T. mentagrophytes were obtained by mycelial growth assays. Then, the qualitative volatile production patterns of the growth responses of these fungi to these values were incorporated into solid medium were analysed after 96-120 hrs incubation at 25° C using headspace analyses. Overall, results, using PCA and CA demonstrated that it is possible to differentiate between various treatments within 96-120 hrs. This study showed that potential exists for using qualitative volatile patterns as a rapid screening method for antifungal agents for microorganism. This approach could also facilitate the monitoring of antimicrobial drug activities and infection control programmes and perhaps drug resistance build up in microbial species.

  5. Aptamer Selection Express: A Novel Method for Rapid Single-Step Selection and Sensing of Aptamers

    PubMed Central

    Fan, Maomian; McBurnett, Shelly Roper; Andrews, Carrie J.; Allman, Amity M.; Bruno, John G.; Kiel, Johnathan L.

    2008-01-01

    Here we describe a new DNA capture element (DCE) sensing system, based on the quenching and dequenching of a double-stranded aptamer. This system shows very good sensitivity and thermal stability. While quenching, dequenching, and separating the DCE systems made from different aptamers (all selected by SELEX), an alternative method to rapidly select aptamers was developed—the Aptamer Selection Express (ASExp). This process has been used to select aptamers against different types of targets (Bacillus anthracis spores, Bacillus thuringiensis spores, MS-2 bacteriophage, ovalbumin, and botulinum neurotoxin). The DCE systems made from botulinum neurotoxin aptamers selected by ASExp have been investigated. The results of this investigation indicate that ASExp can be used to rapidly select aptamers for the DCE sensing system. PMID:19183794

  6. A simple and rapid method for calculating identity-by-descent matrices using multiple markers.

    PubMed

    Pong-Wong, R; George, A W; Woolliams, J A; Haley, C S

    2001-01-01

    A fast, partly recursive deterministic method for calculating Identity-by-Descent (IBD) probabilities was developed with the objective of using IBD in Quantitative Trait Locus (QTL) mapping. The method combined a recursive method for a single marker locus with a method to estimate IBD between sibs using multiple markers. Simulated data was used to compare the deterministic method developed in the present paper with a stochastic method (LOKI) for precision in estimating IBD probabilities and performance in the task of QTL detection with the variance component approach. This comparison was made in a variety of situations by varying family size and degree of polymorphism among marker loci. The following were observed for the deterministic method relative to MCMC: (i) it was an order of magnitude faster; (ii) its estimates of IBD probabilities were found to agree closely, even though it does not extract information when haplotypes are not known with certainty; (iii) the shape of the profile for the QTL test statistic as a function of location was similar, although the magnitude of the test statistic was slightly smaller; and (iv) the estimates of QTL variance was similar. It was concluded that the method proposed provided a rapid means of calculating the IBD matrix with only a small loss in precision, making it an attractive alternative to the use of stochastic MCMC methods. Furthermore, developments in marker technology providing denser maps would enhance the relative advantage of this method.

  7. A simple and rapid method for calculating identity-by-descent matrices using multiple markers

    PubMed Central

    Pong-Wong, Ricardo; George, Andrew Winston; Woolliams, John Arthur; Haley, Chris Simon

    2001-01-01

    A fast, partly recursive deterministic method for calculating Identity-by-Descent (IBD) probabilities was developed with the objective of using IBD in Quantitative Trait Locus (QTL) mapping. The method combined a recursive method for a single marker locus with a method to estimate IBD between sibs using multiple markers. Simulated data was used to compare the deterministic method developed in the present paper with a stochastic method (LOKI) for precision in estimating IBD probabilities and performance in the task of QTL detection with the variance component approach. This comparison was made in a variety of situations by varying family size and degree of polymorphism among marker loci. The following were observed for the deterministic method relative to MCMC: (i) it was an order of magnitude faster; (ii) its estimates of IBD probabilities were found to agree closely, even though it does not extract information when haplotypes are not known with certainty; (iii) the shape of the profile for the QTL test statistic as a function of location was similar, although the magnitude of the test statistic was slightly smaller; and (iv) the estimates of QTL variance was similar. It was concluded that the method proposed provided a rapid means of calculating the IBD matrix with only a small loss in precision, making it an attractive alternative to the use of stochastic MCMC methods. Furthermore, developments in marker technology providing denser maps would enhance the relative advantage of this method. PMID:11712969

  8. Validated flow-injection method for rapid aluminium determination in anti-perspirants.

    PubMed

    López-Gonzálvez, A; Ruiz, M A; Barbas, C

    2008-09-29

    A flow-injection (FI) method for the rapid determination of aluminium in anti-perspirants has been developed. The method is based on the spectrophotometric detection at 535nm of the complex formed between Al ions and the chromogenic reagent eriochrome cyanine R. Both the batch and FI methods were validated by checking the parameters included in the ISO-3543-1 regulation. Variables involved in the FI method were optimized by using appropriate statistical tools. The method does not exhibit interference from other substances present in anti-perspirants and it shows a high precision with a R.S.D. value (n=6) of 0.9%. Moreover, the accuracy of the method was evaluated by comparison with a back complexometric titration method, which is currently used for routine analysis in pharmaceutical laboratories. The Student's t-test showed that the results obtained by both methods were not significantly different for a significance level of 95%. A response time of 12s and a sample analysis time, by performing triplicate injections, of 60s were achieved. The analytical figures of merit make the method highly appropriate to substitute the time-consuming complexometric method for this kind of analysis.

  9. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica.

    PubMed

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P; Brook, Edward J

    2014-05-13

    We present successful (81)Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The (81)Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 ± 2.5 ka. Our experimental methods and sampling strategy are validated by (i) (85)Kr and (39)Ar analyses that show the samples to be free of modern air contamination and (ii) air content measurements that show the ice did not experience gas loss. We estimate the error in the (81)Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130-115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA (81)Kr analysis requires a 40-80-kg ice sample; as sample requirements continue to decrease, (81)Kr dating of ice cores is a future possibility.

  10. Spatial-Temporal Variation of the Radiometric Color of the Largest Ten Lakes in China

    NASA Astrophysics Data System (ADS)

    Li, J.

    2016-02-01

    The optical properties of inland waters are complicated, limiting the use of remote sensing to monitor inland water quality in large regions over long time periods. The radiometric color of water, reflecting overall water quality, is an important parameter in traditional water quality investigations. In this study, we retrieved the Forel-Ule (FU) class radiometric color parameters from MODIS surface reflectance product (MOD09) image, and analyzed its long term time-series variation in the largest ten lakes in China during 2000-2012. Based on validation by in situ measured reflectance data, the MOD09-derived FU products are reliable, with a linear correlation coefficient of 0.97, RMSE of 1.2, and average relative error of 7.7%. Since FU class is an optical parameter, it can be derived from optical remote sensing data without seasonal and area limitations. The FU class products were used to analyze the spatial and temporal variations of turbidity and trophic states in the ten lakes. The largest ten lakes in China include typical types with different optical properties, so the FU class can also be used to assess the quality of other inland waters. The FU class retrieval method can also be applied to other remote sensing data after a simple normalization process. As a result, the FU class radiometric color can be used to assess inland water quality in large regions over long time periods.

  11. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica

    PubMed Central

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V.; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P.; Brook, Edward J.

    2014-01-01

    We present successful 81Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The 81Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 ± 2.5 ka. Our experimental methods and sampling strategy are validated by (i) 85Kr and 39Ar analyses that show the samples to be free of modern air contamination and (ii) air content measurements that show the ice did not experience gas loss. We estimate the error in the 81Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130–115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA 81Kr analysis requires a 40–80-kg ice sample; as sample requirements continue to decrease, 81Kr dating of ice cores is a future possibility. PMID:24753606

  12. Deep Space Network Radiometric Remote Sensing Program

    NASA Technical Reports Server (NTRS)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  13. Deep Space Network Radiometric Remote Sensing Program

    NASA Technical Reports Server (NTRS)

    Walter, Steven J.

    1994-01-01

    Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily

  14. Cellufine sulfate column chromatography as a simple, rapid, and effective method to purify dengue virus.

    PubMed

    Kanlaya, Rattiyaporn; Thongboonkerd, Visith

    2016-08-01

    Conventional method to purify/concentrate dengue virus (DENV) is time-consuming with low virus recovery yield. Herein, we applied cellufine sulfate column chromatography to purify/concentrate DENV based on the mimicry between heparan sulfate and DENV envelope protein. Comparative analysis demonstrated that this new method offered higher purity (as determined by less contamination of bovine serum albumin) and recovery yield (as determined by greater infectivity). Moreover, overall duration used for cellufine sulfate column chromatography to purify/concentrate DENV was approximately 1/20 of that of conventional method. Therefore, cellufine sulfate column chromatography serves as a simple, rapid, and effective alternative method for DENV purification/concentration. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. [Three-Iindex-Value Method for Rapid Screening Unqualified Vegetable Oil].

    PubMed

    He, Wen-xuan; Hong, Gui-shui; Fang, Run; Cai, Xian-chun; Huang, Sheng

    2015-04-01

    In the present study, by measuring the A3 005 (representing unsaturation), A985 (representing conjugated fatty acids), A960 + A985 (representing trans-fatty acid ) of southern common vegetable oils (peanut oil, corn oil, canola oil, soybean oil, sunflower oil, tea seed oil and olive oil), "waste oil" and overdue vegetable oils, the pass-setting-range of these three index values for the vegetable oils was obtained. On this basis, a method for rapid screening unqualified vegetable oil (expired, adding low-cost oil, adding "waste oil") was established. The method effectively improved the monitoring efficiency of vegetable oil. With this method of screening a number of suspected substandard oils were proved unqualified by determination of fatty acid composition and 11, 12, 13, 17 fatty acid content. Through the combination of several detection methods, the causes for disqualification of vegetable oils can be further inferred.

  16. Comparison of rapid methods for chemical analysis of milligram samples of ultrafine clays.

    USGS Publications Warehouse

    Rettig, S.L.; Marinenko, J.W.; Khoury, H.N.; Jones, B.F.

    1983-01-01

    Two rapid methods for the decomposition and chemical analysis of clays were adapted for use with 20-40mg size samples, typical amounts of ultrafine products (< 0.5 micrometer diameter) obtained from modern separation methods for clay minrals. The results of these methods were compared with those of 'classical' rock analyses. The two methods consisted of mixed lithium metaborate fusion and heated decomposition with HF in a closed vessel. The latter technique was modified to include subsequent evaporation with concentrated H2SO4 and re-solution in HCl, which reduced the interference of the fluoride ion in the determination of Al, Fe, Ca, Mg, Na, and K.-from Authors

  17. Comparing High-dimensional Confounder Control Methods for Rapid Cohort Studies From Electronic Health Records

    PubMed Central

    Low, Yen Sia; Gallego, Blanca; Shah, Nigam Haresh

    2016-01-01

    Aims Electronic health records (EHR), containing rich clinical histories of large patient populations, can provide evidence for clinical decisions when evidence from trials and literature is absent. To enable such observational studies from EHR in real time, particularly in emergencies, rapid confounder control methods that can handle numerous variables and adjust for biases are imperative. This study compares the performance of 19 automatic confounder control methods. Methods Methods include propensity scores, direct adjustment by machine learning, similarity matching and resampling in two simulated and one real-world EHR datasets. Results and conclusions Direct adjustment by lasso regression and ensemble models involving multiple resamples have performance comparable to expert-based propensity scores and thus, may help provide real-time EHR-based evidence for timely clinical decisions. PMID:26634383

  18. Rapid quantification of microalgal lipids in aqueous medium by a simple colorimetric method.

    PubMed

    Mishra, Sanjiv K; Suh, William I; Farooq, Wasif; Moon, Myounghoon; Shrivastav, Anupama; Park, Min S; Yang, Ji-Won

    2014-03-01

    Identification of novel microalgal strains with high lipid productivity is one of the most important research topics in renewable biofuel research. However, the major bottleneck in the strain screening process is that currently known methods for the estimation of microalgal lipid are laborious and time-consuming. The present study successfully employed sulpho-phospho-vanillin (SPV) colorimetric method for direct quantitative measurement of lipids within liquid microalgal culture. The SPV reacts with lipids to produce a distinct pink color, and its intensity can be quantified using spectrophotometric methods by measuring absorbance at 530nm. This method was employed for a rapid quantification of intracellular lipid contents within Chlorella sp., Monoraphidium sp., Ettlia sp. and Nannochloropsis sp., all of which were found to have lipid contents ranging in between 10% and 30%. Subsequent analysis of the biomass using gas chromatography confirmed that our protocol is highly accurate (R(2)=0.99).

  19. Rapid microplate, green method for high-throughput evaluation of vinegar acidity using thermal infrared enthalpimetry.

    PubMed

    Tischer, Bruna; Oliveira, Alessandra Stangherlin; Ferreira, Daniele de Freitas; Menezes, Cristiano Ragagnin; Duarte, Fábio Andrei; Wagner, Roger; Barin, Juliano Smanioto

    2017-01-15

    Infrared thermal imaging was combined with disposable microplates to perform enthalpimetric analysis using an infrared camera to monitor temperature without contact. The proposed thermal infrared enthalpimetry (TIE) method was used to determine the total, fixed and volatile acidities of vinegars. Sample preparation and analysis were performed in the same vessel, avoiding excessive sample handling and reducing energy expenditure by more than ten times. The results agreed with those of the conventional method for different kinds of vinegars, with values of 1.7%, and 2.3% for repeatability and intermediate precision, respectively. A linear calibration curve was obtained from 0.040 to 1.30molL(-1). The proposed method provided rapid results (within 10s) for four samples simultaneously, a sample throughput of up to 480 samples per hour. In addition, the method complies with at least eight of twelve recommendations for green analytical chemistry, making TIE a promising tool for routine vinegar analysis.

  20. Rapid quantitative method for total brominated vegetable oil in soft drinks using ion chromatography.

    PubMed

    Yousef, Ashraf A; Abbas, Alaa B; Badawi, Bassam Sh; Al-Jowhar, Wafaa Y; Zain, Esam A; El-Mufti, Seham A

    2012-08-01

    A simple, quantitative and rapid method for total brominated vegetable oil (BVO) using ion chromatography (IC) with suppressed conductivity detection was developed and successfully applied to soft drinks with results expressed as inorganic bromide anion. The procedure involves extraction of BVO with diethyl ether and treatment with zinc dust in a solution of acetic acid, giving recoveries ranging between 92.5 and 98.5%. The calibration curves obtained were linear with correlation coefficients (r²) of 0.998, a coefficient of variation (CV) of less than 5% and limit of detection (LOD) and limit of quantification (LOQ) of 250 and 750 µg l⁻¹, respectively. The method was successfully applied to the determination of BVO in several commercial soft drinks which were found to contain BVO in the range 1.8-14.510 mg l⁻¹. The method has less sources of error compared to previously published methods.