Sample records for rapid sample processing

  1. Rapid Development: A Content Analysis Comparison of Literature and Purposive Sampling of AFRL Rapid Reaction Projects

    DTIC Science & Technology

    2011-12-01

    systems engineering technical and technical management processes. Technical Planning, Stakeholders Requirements Development, and Architecture Design were...Stakeholder Requirements Definition, Architecture Design and Technical Planning. A purposive sampling of AFRL rapid development program managers and engineers...emphasize one process over another however Architecture Design , Implementation scored higher among Technical Processes. Decision Analysis, Technical

  2. Atmospheric Processing Platform | Photovoltaic Research | NREL

    Science.gov Websites

    printing units to the left and sample preparation and rapid thermal processing units to the right. In variety of substrates and then further process into optoelectronic materials using rapid thermal , however, occur within a vacuum (i.e., thermal evaporation, sputtering). Samples can remain in ambient

  3. Apollo Experiment Report: Lunar-Sample Processing in the Lunar Receiving Laboratory High-Vacuum Complex

    NASA Technical Reports Server (NTRS)

    White, D. R.

    1976-01-01

    A high-vacuum complex composed of an atmospheric decontamination system, sample-processing chambers, storage chambers, and a transfer system was built to process and examine lunar material while maintaining quarantine status. Problems identified, equipment modifications, and procedure changes made for Apollo 11 and 12 sample processing are presented. The sample processing experiences indicate that only a few operating personnel are required to process the sample efficiently, safely, and rapidly in the high-vacuum complex. The high-vacuum complex was designed to handle the many contingencies, both quarantine and scientific, associated with handling an unknown entity such as the lunar sample. Lunar sample handling necessitated a complex system that could not respond rapidly to changing scientific requirements as the characteristics of the lunar sample were better defined. Although the complex successfully handled the processing of Apollo 11 and 12 lunar samples, the scientific requirement for vacuum samples was deleted after the Apollo 12 mission just as the vacuum system was reaching its full potential.

  4. Rapid thermal processing by stamping

    DOEpatents

    Stradins, Pauls; Wang, Qi

    2013-03-05

    A rapid thermal processing device and methods are provided for thermal processing of samples such as semiconductor wafers. The device has components including a stamp (35) having a stamping surface and a heater or cooler (40) to bring it to a selected processing temperature, a sample holder (20) for holding a sample (10) in position for intimate contact with the stamping surface; and positioning components (25) for moving the stamping surface and the stamp (35) in and away from intimate, substantially non-pressured contact. Methods for using and making such devices are also provided. These devices and methods allow inexpensive, efficient, easily controllable thermal processing.

  5. Rapid microscale in-gel processing and digestion of proteins using surface acoustic waves.

    PubMed

    Kulkarni, Ketav P; Ramarathinam, Sri H; Friend, James; Yeo, Leslie; Purcell, Anthony W; Perlmutter, Patrick

    2010-06-21

    A new method for in-gel sample processing and tryptic digestion of proteins is described. Sample preparation, rehydration, in situ digestion and peptide extraction from gel slices are dramatically accelerated by treating the gel slice with surface acoustic waves (SAWs). Only 30 minutes total workflow time is required for this new method to produce base peak chromatograms (BPCs) of similar coverage and intensity to those observed for traditional processing and overnight digestion. Simple set up, good reproducibility, excellent peptide recoveries, rapid turnover of samples and high confidence protein identifications put this technology at the fore-front of the next generation of proteomics sample processing tools.

  6. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be < 4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  7. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    PubMed

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be <4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Process dependency of radiation hardness of rapid thermal reoxidized nitrided gate oxides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weishin Lu; Kuanchin Lin; Jenngwo Hwu

    The radiation hardness of MOS capacitors with various reoxidized nitrided oxide (RNO) structures is studied by changing the durations of rapid thermal processes during sample preparation and by applying irradiation-then-anneal (ITA) treatments on samples after preparation. It is found that the initial flatband voltage and midgap interface trap density of MOS capacitors exhibit turnaround'' dependency on the total time of nitridation and reoxidation processes. For samples with nitrided oxide (NO) structures, the radiation-induced variations of above parameters are also turnaround''-dependent on nitridation time. However, when the reoxidation process is performed, the radiation hardness for all samples will be gradually improvedmore » with increasing reoxidation time no matter what the nitridation time is. The most radiation-hard process for RNO structures is suggested. Finally, it is found that when ITA treatments are applied on samples after preparation, their radiation hardness is much improved.« less

  9. High-density Bi-Pb-Sr-Ca-Cu-O superconductor prepared by rapid thermal melt processing

    NASA Astrophysics Data System (ADS)

    Moon, B. M.; Lalevic, B.; Kear, B. H.; McCandlish, L. E.; Safari, A.; Meskoob, M.

    1989-10-01

    A high quality, dense Bi-Pb-Sr-Ca-Cu-O superconductor has been successfully synthesized by rapid thermal melt processing. Conventionally sintered pellets were melted at 1200 °C, cooled rapidly, and then annealed. As-melted samples exhibited semiconductor behavior, which upon annealing became superconducting at 115 K [Tc(zero)=105 K]. A detailed study of various processing techniques has been carried out.

  10. Rapid microfluidic analysis of a Y-STR multiplex for screening of forensic samples.

    PubMed

    Gibson-Daw, Georgiana; Albani, Patricia; Gassmann, Marcus; McCord, Bruce

    2017-02-01

    In this paper, we demonstrate a rapid analysis procedure for use with a small set of rapidly mutating Y chromosomal short tandem repeat (Y-STR) loci that combines both rapid polymerase chain reaction (PCR) and microfluidic separation elements. The procedure involves a high-speed polymerase and a rapid cycling protocol to permit PCR amplification in 16 min. The resultant amplified sample is next analysed using a short 1.8-cm microfluidic electrophoresis system that permits a four-locus Y-STR genotype to be produced in 80 s. The entire procedure takes less than 25 min from sample collection to result. This paper describes the rapid amplification protocol as well as studies of the reproducibility and sensitivity of the procedure and its optimisation. The amplification process utilises a small high-speed thermocycler, microfluidic device and compact laptop, making it portable and potentially useful for rapid, inexpensive on-site genotyping. The four loci used for the multiplex were selected due to their rapid mutation rates and should proved useful in preliminary screening of samples and suspects. Overall, this technique provides a method for rapid sample screening of suspect and crime scene samples in forensic casework. Graphical abstract ᅟ.

  11. Hydroxyapatite Coatings on High Nitrogen Stainless Steel by Laser Rapid Manufacturing

    NASA Astrophysics Data System (ADS)

    Das, Ashish; Shukla, Mukul

    2017-11-01

    In this research, the laser rapid manufacturing (LRM) additive manufacturing process was used to deposit multifunctional hydroxyapatite (HAP) coatings on high nitrogen stainless steel. LRM overcomes the limitations of conventional coating processes by producing coatings with metallurgical bond, osseointegration, and infection inhibition properties. The microstructure, microhardness, antibacterial efficacy, and bioactivity of the coatings were investigated. The microstructure studies established that the coatings consist of austenite dendrites with HAP and some reaction products primarily occurring in the inter-dendritic regions. A Vickers microhardness test confirmed the hardness values of deposited HAP coatings to be higher than those of the bare 254SS samples, while a fluorescence activated cell sorting test confirmed their superior antibacterial properties as compared with pristine samples. The coated samples immersed in simulated body fluid showed rapid apatite forming ability. The results obtained in this research signify the potential application of the LRM process in synthesizing multifunctional orthopaedic coatings.

  12. Rapid method for sampling metals for materials identification

    NASA Technical Reports Server (NTRS)

    Higgins, L. E.

    1971-01-01

    Nondamaging process similar to electrochemical machining is useful in obtaining metal samples from places inaccessible to conventional sampling methods or where methods would be hazardous or contaminating to specimens. Process applies to industries where metals or metal alloys play a vital role.

  13. Rapid DNA analysis for automated processing and interpretation of low DNA content samples.

    PubMed

    Turingan, Rosemary S; Vasantgadkar, Sameer; Palombo, Luke; Hogan, Catherine; Jiang, Hua; Tan, Eugene; Selden, Richard F

    2016-01-01

    Short tandem repeat (STR) analysis of casework samples with low DNA content include those resulting from the transfer of epithelial cells from the skin to an object (e.g., cells on a water bottle, or brim of a cap), blood spatter stains, and small bone and tissue fragments. Low DNA content (LDC) samples are important in a wide range of settings, including disaster response teams to assist in victim identification and family reunification, military operations to identify friend or foe, criminal forensics to identify suspects and exonerate the innocent, and medical examiner and coroner offices to identify missing persons. Processing LDC samples requires experienced laboratory personnel, isolated workstations, and sophisticated equipment, requires transport time, and involves complex procedures. We present a rapid DNA analysis system designed specifically to generate STR profiles from LDC samples in field-forward settings by non-technical operators. By performing STR in the field, close to the site of collection, rapid DNA analysis has the potential to increase throughput and to provide actionable information in real time. A Low DNA Content BioChipSet (LDC BCS) was developed and manufactured by injection molding. It was designed to function in the fully integrated Accelerated Nuclear DNA Equipment (ANDE) instrument previously designed for analysis of buccal swab and other high DNA content samples (Investigative Genet. 4(1):1-15, 2013). The LDC BCS performs efficient DNA purification followed by microfluidic ultrafiltration of the purified DNA, maximizing the quantity of DNA available for subsequent amplification and electrophoretic separation and detection of amplified fragments. The system demonstrates accuracy, precision, resolution, signal strength, and peak height ratios appropriate for casework analysis. The LDC rapid DNA analysis system is effective for the generation of STR profiles from a wide range of sample types. The technology broadens the range of sample types that can be processed and minimizes the time between sample collection, sample processing and analysis, and generation of actionable intelligence. The fully integrated Expert System is capable of interpreting a wide range or sample types and input DNA quantities, allowing samples to be processed and interpreted without a technical operator.

  14. Validation of a rapid DNA process with the RapidHIT® ID system using GlobalFiler® Express chemistry, a platform optimized for decentralized testing environments.

    PubMed

    Salceda, Susana; Barican, Arnaldo; Buscaino, Jacklyn; Goldman, Bruce; Klevenberg, Jim; Kuhn, Melissa; Lehto, Dennis; Lin, Frank; Nguyen, Phong; Park, Charles; Pearson, Francesca; Pittaro, Rick; Salodkar, Sayali; Schueren, Robert; Smith, Corey; Troup, Charles; Tsou, Dean; Vangbo, Mattias; Wunderle, Justus; King, David

    2017-05-01

    The RapidHIT ® ID is a fully automated sample-to-answer system for short tandem repeat (STR)-based human identification. The RapidHIT ID has been optimized for use in decentralized environments and processes presumed single source DNA samples, generating Combined DNA Index System (CODIS)-compatible DNA profiles in less than 90min. The system is easy to use, requiring less than one minute of hands-on time. Profiles are reviewed using centralized linking software, RapidLINK™ (IntegenX, Pleasanton, CA), a software tool designed to collate DNA profiles from single or multiple RapidHIT ID systems at different geographic locations. The RapidHIT ID has been designed to employ GlobalFiler ® Express and AmpFLSTR ® NGMSElect™, Thermo Fisher Scientific (Waltham, MA) STR chemistries. The Developmental Validation studies were performed using GlobalFiler ® Express with single source reference samples according to Scientific Working Group for DNA Analysis Methods guidelines. These results show that multiple RapidHIT ID systems networked with RapidLINK software form a highly reliable system for wide-scale deployment in locations such as police booking stations and border crossings enabling real-time testing of arrestees, potential human trafficking victims, and other instances where rapid turnaround is essential. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  15. Simple Sample Processing Enhances Malaria Rapid Diagnostic Test Performance

    PubMed Central

    Davis, K. M.; Gibson, L. E.; Haselton, F. R.; Wright, D. W.

    2016-01-01

    Lateral flow immunochromatographic rapid diagnostic tests (RDTs) are the primary form of medical diagnostic used for malaria in underdeveloped nations. Unfortunately, many of these tests do not detect asymptomatic malaria carriers. In order for eradication of the disease to be achieved, this problem must be solved. In this study, we demonstrate enhancement in the performance of six RDT brands when a simple sample-processing step is added to the front of the diagnostic process. Greater than a 4-fold RDT signal enhancement was observed as a result of the sample processing step. This lowered the limit of detection for RDT brands to submicroscopic parasitemias. For the best performing RDTs the limits of detection were found to be as low as 3 parasites/μL. Finally, through individual donor samples, the correlations between donor source, WHO panel detection scores and RDT signal intensities were explored. PMID:24787948

  16. Simple sample processing enhances malaria rapid diagnostic test performance.

    PubMed

    Davis, K M; Gibson, L E; Haselton, F R; Wright, D W

    2014-06-21

    Lateral flow immunochromatographic rapid diagnostic tests (RDTs) are the primary form of medical diagnostic used for malaria in underdeveloped nations. Unfortunately, many of these tests do not detect asymptomatic malaria carriers. In order for eradication of the disease to be achieved, this problem must be solved. In this study, we demonstrate enhancement in the performance of six RDT brands when a simple sample-processing step is added to the front of the diagnostic process. Greater than a 4-fold RDT signal enhancement was observed as a result of the sample processing step. This lowered the limit of detection for RDT brands to submicroscopic parasitemias. For the best performing RDTs the limits of detection were found to be as low as 3 parasites per μL. Finally, through individual donor samples, the correlations between donor source, WHO panel detection scores and RDT signal intensities were explored.

  17. Rapid Decisions From Experience

    PubMed Central

    Zeigenfuse, Matthew D.; Pleskac, Timothy J.; Liu, Taosheng

    2014-01-01

    In many everyday decisions, people quickly integrate noisy samples of information to form a preference among alternatives that offer uncertain rewards. Here, we investigated this decision process using the Flash Gambling Task (FGT), in which participants made a series of choices between a certain payoff and an uncertain alternative that produced a normal distribution of payoffs. For each choice, participants experienced the distribution of payoffs via rapid samples updated every 50 ms. We show that people can make these rapid decisions from experience and that the decision process is consistent with a sequential sampling process. Results also reveal a dissociation between these preferential decisions and equivalent perceptual decisions where participants had to determine which alternatives contained more dots on average. To account for this dissociation, we developed a sequential sampling rank-dependent utility model, which showed that participants in the FGT attended more to larger potential payoffs than participants in the perceptual task despite being given equivalent information. We discuss the implications of these findings in terms of computational models of preferential choice and a more complete understanding of experience-based decision making. PMID:24549141

  18. An integratable microfluidic cartridge for forensic swab samples lysis.

    PubMed

    Yang, Jianing; Brooks, Carla; Estes, Matthew D; Hurth, Cedric M; Zenhausern, Frederic

    2014-01-01

    Fully automated rapid forensic DNA analysis requires integrating several multistep processes onto a single microfluidic platform, including substrate lysis, extraction of DNA from the released lysate solution, multiplexed PCR amplification of STR loci, separation of PCR products by capillary electrophoresis, and analysis for allelic peak calling. Over the past several years, most of the rapid DNA analysis systems developed started with the reference swab sample lysate and involved an off-chip lysis of collected substrates. As a result of advancement in technology and chemistry, addition of a microfluidic module for swab sample lysis has been achieved in a few of the rapid DNA analysis systems. However, recent reports on integrated rapid DNA analysis systems with swab-in and answer-out capability lack any quantitative and qualitative characterization of the swab-in sample lysis module, which is important for downstream forensic sample processing. Maximal collection and subsequent recovery of the biological material from the crime scene is one of the first and critical steps in forensic DNA technology. Herein we present the design, fabrication and characterization of an integratable swab lysis cartridge module and the test results obtained from different types of commonly used forensic swab samples, including buccal, saliva, and blood swab samples, demonstrating the compatibility with different downstream DNA extraction chemistries. This swab lysis cartridge module is easy to operate, compatible with both forensic and microfluidic requirements, and ready to be integrated with our existing automated rapid forensic DNA analysis system. Following the characterization of the swab lysis module, an integrated run from buccal swab sample-in to the microchip CE electropherogram-out was demonstrated on the integrated prototype instrument. Therefore, in this study, we demonstrate that this swab lysis cartridge module is: (1) functionally, comparable with routine benchtop lysis, (2) compatible with various types of swab samples and chemistries, and (3) integratable to achieve a micro total analysis system (μTAS) for rapid DNA analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Rapid Radiochemical Methods for Asphalt Paving Material ...

    EPA Pesticide Factsheets

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  20. Flight Planning for the International Space Station - Levitation Observation of Dendrite Evolution in Steel Ternary Alloy Rapid Solidification (LODESTARS)

    NASA Technical Reports Server (NTRS)

    Flemings, Merton C.; Matson, Douglas M.; Hyers, Robert W.; Rogers, Jan R.

    2003-01-01

    During rapid solidification, a molten sample is cooled below its equilibrium solidification temperature to form a metastable liquid. Once nucleation is initiated, growth of the solid phase proceeds and can be seen as a sudden rise in temperature. The heat of fusion is rejected ahead of the growing dendrites into the undercooled liquid in a process known as recalescence. Fe-Cr-Ni alloys may form several equilibrium phases and the hypoeutectic alloys, with compositions near the commercially important 316 stainless steel alloy, are observed to solidify by way of a two-step process known as double recalescence. During double recalescence, the first temperature rise is associated with formation of the metastable ferritic solid phase with subsequent conversion to the stable austenitic phase during the second temperature rise. Selection of which phase grows into the undercooled melt during primary solidification may be accomplished by choice of the appropriate nucleation trigger material or by control of the processing parameters during rapid solidification. Due to the highly reactive nature of the molten sample material and in order to avoid contamination of the undercooled melt, a containerless electromagnetic levitation (EML) processing technique is used. In ground-based EML, the same forces that support the weight of the sample against gravity also drive convection in the liquid sample. However, in microgravity, the force required to position the sample is greatly reduced, so convection may be controlled over a wide range of internal flows. Space Shuttle experiments have shown that the double recalescence behavior of Fe-Cr-Ni alloys changes between ground and space EML experiments. This program is aimed at understanding how melt convection influences phase selection and the evolution of rapid solidification microstructures.

  1. Straightforward rapid spectrophotometric quantification of total cyanogenic glycosides in fresh and processed cassava products.

    PubMed

    Tivana, Lucas Daniel; Da Cruz Francisco, Jose; Zelder, Felix; Bergenståhl, Bjorn; Dejmek, Petr

    2014-09-01

    In this study, we extend pioneering studies and demonstrate straightforward applicability of the corrin-based chemosensor, aquacyanocobyrinic acid (ACCA), for the instantaneous detection and rapid quantification of endogenous cyanide in fresh and processed cassava roots. Hydrolytically liberated endogenous cyanide from cyanogenic glycosides (CNp) reacts with ACCA to form dicyanocobyrinic acid (DCCA), accompanied by a change of colour from orange to violet. The method was successfully tested on various cassava samples containing between 6 and 200 mg equiv. HCN/kg as verified with isonicotinate/1,3-dimethylbarbiturate as an independent method. The affinity of ACCA sensor to cyanide is high, coordination occurs fast and the colorimetric response can therefore be instantaneously monitored with spectrophotometric methods. Direct applications of the sensor without need of extensive and laborious extraction processes are demonstrated in water-extracted samples, in acid-extracted samples, and directly on juice drops. ACCA showed high precision with a standard deviation (STDV) between 0.03 and 0.06 and high accuracy (93-96%). Overall, the ACCA procedure is straightforward, safe and easily performed. In a proof-of-concept study, rapid screening of ten samples within 20 min has been tested. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Quick counting method for estimating the number of viable microbes on food and food processing equipment.

    PubMed

    Winter, F H; York, G K; el-Nakhal, H

    1971-07-01

    A rapid method for estimating the extent of microbial contamination on food and on food processing equipment is described. Microbial cells are rinsed from food or swab samples with sterile diluent and concentrated on the surface of membrane filters. The filters are incubated on a suitable bacteriological medium for 4 hr at 30 C, heated at 105 C for 5 min, and stained. The membranes are then dried at 60 C for 15 min, rendered transparent with immersion oil, and examined microscopically. Data obtained by the rapid method were compared with counts of the same samples determined by the standard plate count method. Over 60 comparisons resulted in a correlation coefficient of 0.906. Because the rapid technique can provide reliable microbiological count information in extremely short times, it can be a most useful tool in the routine evaluation of microbial contamination of food processing facilities and for some foods.

  3. Rapid extraction and assay of uranium from environmental surface samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonatemore » and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.« less

  4. A Rapid Identification Method for Calamine Using Near-Infrared Spectroscopy Based on Multi-Reference Correlation Coefficient Method and Back Propagation Artificial Neural Network.

    PubMed

    Sun, Yangbo; Chen, Long; Huang, Bisheng; Chen, Keli

    2017-07-01

    As a mineral, the traditional Chinese medicine calamine has a similar shape to many other minerals. Investigations of commercially available calamine samples have shown that there are many fake and inferior calamine goods sold on the market. The conventional identification method for calamine is complicated, therefore as a result of the large scale of calamine samples, a rapid identification method is needed. To establish a qualitative model using near-infrared (NIR) spectroscopy for rapid identification of various calamine samples, large quantities of calamine samples including crude products, counterfeits and processed products were collected and correctly identified using the physicochemical and powder X-ray diffraction method. The NIR spectroscopy method was used to analyze these samples by combining the multi-reference correlation coefficient (MRCC) method and the error back propagation artificial neural network algorithm (BP-ANN), so as to realize the qualitative identification of calamine samples. The accuracy rate of the model based on NIR and MRCC methods was 85%; in addition, the model, which took comprehensive multiple factors into consideration, can be used to identify crude calamine products, its counterfeits and processed products. Furthermore, by in-putting the correlation coefficients of multiple references as the spectral feature data of samples into BP-ANN, a BP-ANN model of qualitative identification was established, of which the accuracy rate was increased to 95%. The MRCC method can be used as a NIR-based method in the process of BP-ANN modeling.

  5. Effect of Annealing Processes on Cu-Zr Alloy Film for Copper Metallization

    NASA Astrophysics Data System (ADS)

    Wang, Ying; Li, Fu-yin; Tang, Bin-han

    2017-12-01

    The effect of two different annealing processes on the microstructure and barrier-forming ability of Cu-Zr alloy films has been investigated. Cu-Zr alloy films were deposited directly onto SiO2/Si substrates via direct current magnetron sputtering and subsequently annealed by the vacuum annealing process (VAP) or rapid annealing process under argon atmosphere at temperatures 350°C, 450°C, and 550°C. Then, the microstructure, interface characteristics, and electrical properties of the samples were measured. After annealing, the samples showed a preferential (111) crystal orientation, independent of the annealing process. After two annealing methods, Zr aggregated at the Cu-Zr/SiO2 interface and no serious interdiffusion occurred between Cu and Si. The leakage current measurements revealed that the samples annealed by VAP show a higher reliability. According to the results, the vacuum annealing has better barrier performance than the rapid annealing when used for the fabrication of Cu-based interconnects.

  6. Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing

    PubMed Central

    Vutyavanich, Teraporn; Lattiwongsakorn, Worashorn; Piromlertamorn, Waraporn; Samchimchom, Sudarat

    2012-01-01

    In this study, we compared the effects of repeated freezing/thawing of human sperm by our in-house method of rapid freezing with slow programmable freezing. Sperm samples from 11 normozoospermic subjects were processed through density gradients and divided into three aliquots: non-frozen, rapid freezing and slow programmable freezing. Sperm in the rapid freezing group had better motility and viability than those in the slow freezing group (P<0.01) after the first, second and third cycles of freezing/thawing, but there was no difference in morphology. In the second experiment, rapid freezing was repeated three times in 20 subjects. The samples from each thawing cycle were evaluated for DNA fragmentation using the alkaline comet assay. DNA fragmentation began to increase considerably after the second cycle of freezing/thawing, but to a level that was not clinically important. In the third experiment, rapid freezing was done repeatedly in 10 subjects, until no motile sperm were observed after thawing. The median number of repeated freezing/thawing that yielded no motile sperm was seven (range: 5–8, mean: 6.8). In conclusion, we demonstrated that repeated freezing/thawing of processed semen using our rapid freezing method gave better results than standard slow programmable freezing. This method can help maximize the usage of precious cryopreserved sperm samples in assisted reproduction technology. PMID:23064685

  7. Rapid evolution in insect pests: the importance of space and time in population genomics studies.

    PubMed

    Pélissié, Benjamin; Crossley, Michael S; Cohen, Zachary Paul; Schoville, Sean D

    2018-04-01

    Pest species in agroecosystems often exhibit patterns of rapid evolution to environmental and human-imposed selection pressures. Although the role of adaptive processes is well accepted, few insect pests have been studied in detail and most research has focused on selection at insecticide resistance candidate genes. Emerging genomic datasets provide opportunities to detect and quantify selection in insect pest populations, and address long-standing questions about mechanisms underlying rapid evolutionary change. We examine the strengths of recent studies that stratify population samples both in space (along environmental gradients and comparing ancestral vs. derived populations) and in time (using chronological sampling, museum specimens and comparative phylogenomics), resulting in critical insights on evolutionary processes, and providing new directions for studying pests in agroecosystems. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Integration and segregation of large-scale brain networks during short-term task automatization

    PubMed Central

    Mohr, Holger; Wolfensteller, Uta; Betzel, Richard F.; Mišić, Bratislav; Sporns, Olaf; Richiardi, Jonas; Ruge, Hannes

    2016-01-01

    The human brain is organized into large-scale functional networks that can flexibly reconfigure their connectivity patterns, supporting both rapid adaptive control and long-term learning processes. However, it has remained unclear how short-term network dynamics support the rapid transformation of instructions into fluent behaviour. Comparing fMRI data of a learning sample (N=70) with a control sample (N=67), we find that increasingly efficient task processing during short-term practice is associated with a reorganization of large-scale network interactions. Practice-related efficiency gains are facilitated by enhanced coupling between the cingulo-opercular network and the dorsal attention network. Simultaneously, short-term task automatization is accompanied by decreasing activation of the fronto-parietal network, indicating a release of high-level cognitive control, and a segregation of the default mode network from task-related networks. These findings suggest that short-term task automatization is enabled by the brain's ability to rapidly reconfigure its large-scale network organization involving complementary integration and segregation processes. PMID:27808095

  9. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy.

    PubMed

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories.

  10. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy

    PubMed Central

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818

  11. Sequential elution process

    DOEpatents

    Kingsley, I.S.

    1987-01-06

    A process and apparatus are disclosed for the separation of complex mixtures of carbonaceous material by sequential elution with successively stronger solvents. In the process, a column containing glass beads is maintained in a fluidized state by a rapidly flowing stream of a weak solvent, and the sample is injected into this flowing stream such that a portion of the sample is dissolved therein and the remainder of the sample is precipitated therein and collected as a uniform deposit on the glass beads. Successively stronger solvents are then passed through the column to sequentially elute less soluble materials. 1 fig.

  12. Procedure for rapid determination of δ15N and δ18O values of nitrate: development and application to an irrigated rice paddy watershed.

    PubMed

    Yada, Saeko; Nakajima, Yasuhiro; Itahashi, Sunao; Asada, Kei; Yoshikawa, Seiko; Eguchi, Sadao

    2016-01-01

    The dual isotope approach using the stable isotope ratios of nitrate nitrogen (δ(15)N(NO3)) and oxygen (δ(18)O(NO3)) is a strong tool for identifying the history of nitrate in various environments. Basically, a rapid procedure for determining δ(15)N(NO3) and δ(18)O(NO3) values is required to analyze many more samples quickly and thus save on the operational costs of isotope-ratio mass spectrometry (IRMS). We developed a new rapid procedure to save time by pre-treating consecutive samples of nitrous oxide microbially converted from nitrate before IRMS determination. By controlling two six-port valves of the pre-treatment system separately, IRMS determination of the current sample and backflush during the next sample pre-treatment period could be conducted simultaneously. A set of 89 samples was analyzed precisely during a 25-h continuous run (17 min per sample), giving the fastest reported processing time, and simultaneously reducing liquid nitrogen and carrier helium gas consumption by 35%. Application of the procedure to an irrigated rice paddy watershed suggested that nitrate concentrations in river waters decreased in a downstream direction, mainly because of the mixing of nitrate from different sources, without distinct evidence of denitrification. Our procedure should help with more detailed studies of nitrate formation processes in watersheds.

  13. Effect of cooling rate upon processing characteristics of pork meat of different glycolysis type during post mortem ageing.

    PubMed

    Vada, M

    1977-10-01

    Rapid chilling was applied to porcine longissimus dorsi muscles at 1 h post mortem in order to observe its effect on the quality of canned products prepared from those of different pH(1) values. The muscle from one side of each animal was removed from the carcase 50 minutes post mortem and divided into two longitudinal strips. One was chilled immediately to 13-15°C (1 h post mortem): the other after a further hour (2 h post mortem) acted as control. After the centre temperature had reached 10°C the muscles were stored in a refrigerator at 3-5°C. Compared with the control samples (chilled at 2 h p.m.), rapid chilling from 1 h p.m. caused an improvement in the water-holding capacity and the texture of pork meat, which had higher pH(1) values and was processed at 2, 4 and 48 h p.m. There was minimum brine retention and texture score if samples-both rapidly chilled and control-were processed at 24 h p.m. Although brine retention of PSE pork meat could not be increased even by rapid chilling, the texture of heat treated PSE pork showed an improvement during storage, which was more pronounced after ageing for 48 h, if PSE samples were chilled at 1 h p.m. Copyright © 1977. Published by Elsevier Ltd.

  14. Rapid prediction of ochratoxin A-producing strains of Penicillium on dry-cured meat by MOS-based electronic nose.

    PubMed

    Lippolis, Vincenzo; Ferrara, Massimo; Cervellieri, Salvatore; Damascelli, Anna; Epifani, Filomena; Pascale, Michelangelo; Perrone, Giancarlo

    2016-02-02

    The availability of rapid diagnostic methods for monitoring ochratoxigenic species during the seasoning processes for dry-cured meats is crucial and constitutes a key stage in order to prevent the risk of ochratoxin A (OTA) contamination. A rapid, easy-to-perform and non-invasive method using an electronic nose (e-nose) based on metal oxide semiconductors (MOS) was developed to discriminate dry-cured meat samples in two classes based on the fungal contamination: class P (samples contaminated by OTA-producing Penicillium strains) and class NP (samples contaminated by OTA non-producing Penicillium strains). Two OTA-producing strains of Penicillium nordicum and two OTA non-producing strains of Penicillium nalgiovense and Penicillium salamii, were tested. The feasibility of this approach was initially evaluated by e-nose analysis of 480 samples of both Yeast extract sucrose (YES) and meat-based agar media inoculated with the tested Penicillium strains and incubated up to 14 days. The high recognition percentages (higher than 82%) obtained by Discriminant Function Analysis (DFA), either in calibration and cross-validation (leave-more-out approach), for both YES and meat-based samples demonstrated the validity of the used approach. The e-nose method was subsequently developed and validated for the analysis of dry-cured meat samples. A total of 240 e-nose analyses were carried out using inoculated sausages, seasoned by a laboratory-scale process and sampled at 5, 7, 10 and 14 days. DFA provided calibration models that permitted discrimination of dry-cured meat samples after only 5 days of seasoning with mean recognition percentages in calibration and cross-validation of 98 and 88%, respectively. A further validation of the developed e-nose method was performed using 60 dry-cured meat samples produced by an industrial-scale seasoning process showing a total recognition percentage of 73%. The pattern of volatile compounds of dry-cured meat samples was identified and characterized by a developed HS-SPME/GC-MS method. Seven volatile compounds (2-methyl-1-butanol, octane, 1R-α-pinene, d-limonene, undecane, tetradecanal, 9-(Z)-octadecenoic acid methyl ester) allowed discrimination between dry-cured meat samples of classes P and NP. These results demonstrate that MOS-based electronic nose can be a useful tool for a rapid screening in preventing OTA contamination in the cured meat supply chain. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Rapid Waterborne Pathogen Detection with Mobile Electronics.

    PubMed

    Wu, Tsung-Feng; Chen, Yu-Chen; Wang, Wei-Chung; Kucknoor, Ashwini S; Lin, Che-Jen; Lo, Yu-Hwa; Yao, Chun-Wei; Lian, Ian

    2017-06-09

    Pathogen detection in water samples, without complex and time consuming procedures such as fluorescent-labeling or culture-based incubation, is essential to public safety. We propose an immunoagglutination-based protocol together with the microfluidic device to quantify pathogen levels directly from water samples. Utilizing ubiquitous complementary metal-oxide-semiconductor (CMOS) imagers from mobile electronics, a low-cost and one-step reaction detection protocol is developed to enable field detection for waterborne pathogens. 10 mL of pathogen-containing water samples was processed using the developed protocol including filtration enrichment, immune-reaction detection and imaging processing. The limit of detection of 10 E. coli O157:H7 cells/10 mL has been demonstrated within 10 min of turnaround time. The protocol can readily be integrated into a mobile electronics such as smartphones for rapid and reproducible field detection of waterborne pathogens.

  16. RAPID DETERMINATION OF RA-226 IN ENVIRONMENTAL SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.

    2012-01-03

    A new rapid method for the determination of {sup 226}Ra in environmental samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for emergency response or routine sample analyses. The need for rapid analyses in the event of a Radiological Dispersive Device or Improvised Nuclear Device event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. {sup 226}Ra (T1/2 = 1,620 years) is one of the mostmore » toxic of the long-lived alpha-emitters present in the environment due to its long life and its tendency to concentrate in bones, which increases the internal radiation dose of individuals. The new method to determine {sup 226}Ra in environmental samples utilizes a rapid sodium hydroxide fusion method for solid samples, calcium carbonate precipitation to preconcentrate Ra, and rapid column separation steps to remove interferences. The column separation process uses cation exchange resin to remove large amounts of calcium, Sr Resin to remove barium and Ln Resin as a final purification step to remove {sup 225}Ac and potential interferences. The purified {sup 226}Ra sample test sources are prepared using barium sulfate microprecipitation in the presence of isopropanol for counting by alpha spectrometry. The method showed good chemical recoveries and effective removal of interferences. The determination of {sup 226}Ra in environmental samples can be performed in less than 16 h for vegetation, concrete, brick, soil, and air filter samples with excellent quality for emergency or routine analyses. The sample preparation work takes less than 6 h. {sup 225}Ra (T1/2 = 14.9 day) tracer is used and the {sup 225}Ra progeny {sup 217}At is used to determine chemical yield via alpha spectrometry. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory radium particles are effectively digested. The preconcentration and column separation steps can also be applied to aqueous samples with good results.« less

  17. Method development in high-performance liquid chromatography for high-throughput profiling and metabonomic studies of biofluid samples.

    PubMed

    Pham-Tuan, Hai; Kaskavelis, Lefteris; Daykin, Clare A; Janssen, Hans-Gerd

    2003-06-15

    "Metabonomics" has in the past decade demonstrated enormous potential in furthering the understanding of, for example, disease processes, toxicological mechanisms, and biomarker discovery. The same principles can also provide a systematic and comprehensive approach to the study of food ingredient impact on consumer health. However, "metabonomic" methodology requires the development of rapid, advanced analytical tools to comprehensively profile biofluid metabolites within consumers. Until now, NMR spectroscopy has been used for this purpose almost exclusively. Chromatographic techniques and in particular HPLC, have not been exploited accordingly. The main drawbacks of chromatography are the long analysis time, instabilities in the sample fingerprint and the rigorous sample preparation required. This contribution addresses these problems in the quest to develop generic methods for high-throughput profiling using HPLC. After a careful optimization process, stable fingerprints of biofluid samples can be obtained using standard HPLC equipment. A method using a short monolithic column and a rapid gradient with a high flow-rate has been developed that allowed rapid and detailed profiling of larger numbers of urine samples. The method can be easily translated into a slow, shallow-gradient high-resolution method for identification of interesting peaks by LC-MS/NMR. A similar approach has been applied for cell culture media samples. Due to the much higher protein content of such samples non-porous polymer-based small particle columns yielded the best results. The study clearly shows that HPLC can be used in metabonomic fingerprinting studies.

  18. A novel rapid analysis using mass spectrometry to evaluate downstream refolding of recombinant human insulin-like growth factor-1 (mecasermin).

    PubMed

    Furuki, Kenichiro; Toyo'oka, Toshimasa; Yamaguchi, Hideto

    2017-08-15

    Mecasermin is used to treat elevated blood sugar as well as growth-hormone-resistant Laron-type dwarfism. Mecasermin isolated from inclusion bodies in extracts of E. coli must be refolded to acquire sufficient activity. However, there is no rapid analytical method for monitoring refolding during the purification process. We prepared mecasermin drug product, in-process samples during the oxidation of mecasermin, forced-reduced mecasermin, and aerially oxidized mecasermin after forced reduction. Desalted mecasermin samples were analyzed using MALDI-ISD. The peak intensity ratio of product to precursor ion was determined. The charge-state distribution (CSD) of mecasermin ions was evaluated using ESI-MS coupled with SEC-mode HPLC. The drift time and collision cross-sectional area (CCS) of mecasermin ions were evaluated using ESI-IMS-MS coupled with SEC-mode HPLC. MALDI-ISD data, CSD values determined using ESI-MS, and the CCS acquired using ESI-IMS-MS revealed the relationship between the folded and unfolded proteoforms of forced-reduced mecasermin and aerially oxidized mecasermin with the free-SH:protein ratio of mecasermin drug product. The CCS area, which is determined using ESI-IMS-MS, provided proteoform information through rapid monitoring (<2 min) of in-process samples during the manufacture of mecasermin. ESI-IMS-MS coupled with SEC-mode HPLC is a rapid and robust method for analyzing the free-SH:protein ratio of mecasermin that allows proteoform changes to be evaluated and monitored during the oxidation of mecasermin. ESI-IMS-MS is applicable as a process analytical technology tool for identifying the "critical quality attributes" and implementing "quality by design" for manufacturing mecasermin. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Development of Novel Method for Rapid Extract of Radionuclides from Solution Using Polymer Ligand Film

    NASA Astrophysics Data System (ADS)

    Rim, Jung H.

    Accurate and fast determination of the activity of radionuclides in a sample is critical for nuclear forensics and emergency response. Radioanalytical techniques are well established for radionuclides measurement, however, they are slow and labor intensive, requiring extensive radiochemical separations and purification prior to analysis. With these limitations of current methods, there is great interest for a new technique to rapidly process samples. This dissertation describes a new analyte extraction medium called Polymer Ligand Film (PLF) developed to rapidly extract radionuclides. Polymer Ligand Film is a polymer medium with ligands incorporated in its matrix that selectively and rapidly extract analytes from a solution. The main focus of the new technique is to shorten and simplify the procedure necessary to chemically isolate radionuclides for determination by alpha spectrometry or beta counting. Five different ligands were tested for plutonium extraction: bis(2-ethylhexyl) methanediphosphonic acid (H2DEH[MDP]), di(2-ethyl hexyl) phosphoric acid (HDEHP), trialkyl methylammonium chloride (Aliquat-336), 4,4'(5')-di-t-butylcyclohexano 18-crown-6 (DtBuCH18C6), and 2-ethylhexyl 2-ethylhexylphosphonic acid (HEH[EHP]). The ligands that were effective for plutonium extraction further studied for uranium extraction. The plutonium recovery by PLFs has shown dependency on nitric acid concentration and ligand to total mass ratio. H2DEH[MDP] PLFs performed best with 1:10 and 1:20 ratio PLFs. 50.44% and 47.61% of plutonium were extracted on the surface of PLFs with 1M nitric acid for 1:10 and 1:20 PLF, respectively. HDEHP PLF provided the best combination of alpha spectroscopy resolution and plutonium recovery with 1:5 PLF when used with 0.1M nitric acid. The overall analyte recovery was lower than electrodeposited samples, which typically has recovery above 80%. However, PLF is designed to be a rapid field deployable screening technique and consistency is more important than recovery. PLFs were also tested using blind quality control samples and the activities were accurately measured. It is important to point out that PLFs were consistently susceptible to analytes penetrating and depositing below the surface. The internal radiation within the body of PLF is mostly contained and did not cause excessive self-attenuation and peak broadening in alpha spectroscopy. The analyte penetration issue was beneficial in the destructive analysis. H2DEH[MDP] PLF was tested with environmental samples to fully understand the capabilities and limitations of the PLF in relevant environments. The extraction system was very effective in extracting plutonium from environmental water collected from Mortandad Canyon at Los Alamos National Laboratory with minimal sample processing. Soil samples were tougher to process than the water samples. Analytes were first leached from the soil matrixes using nitric acid before processing with PLF. This approach had a limitation in extracting plutonium using PLF. The soil samples from Mortandad Canyon, which are about 1% iron by weight, were effectively processed with the PLF system. Even with certain limitations of the PLF extraction system, this technique was able to considerably decrease the sample analysis time. The entire environmental sample was analyzed within one to two days. The decrease in time can be attributed to the fact that PLF is replacing column chromatography and electrodeposition with a single step for preparing alpha spectrometry samples. The two-step process of column chromatography and electrodeposition takes a couple days to a week to complete depending on the sample. The decrease in time and the simplified procedure make this technique a unique solution for application to nuclear forensics and emergency response. A large number of samples can be quickly analyzed and selective samples can be further analyzed with more sensitive techniques based on the initial data. The deployment of a PLF system as a screening method will greatly reduce a total analysis time required to gain meaningful isotopic data for the nuclear forensics application. (Abstract shortened by UMI.)

  20. Validation of Rapid Radiochemical Method for Californium ...

    EPA Pesticide Factsheets

    Technical Brief In the event of a radiological/nuclear contamination event, the response community would need tools and methodologies to rapidly assess the nature and the extent of contamination. To characterize a radiologically contaminated outdoor area and to inform risk assessment, large numbers of environmental samples would be collected and analyzed over a short period of time. To address the challenge of quickly providing analytical results to the field, the U.S. EPA developed a robust analytical method. This method allows response officials to characterize contaminated areas and to assess the effectiveness of remediation efforts, both rapidly and accurately, in the intermediate and late phases of environmental cleanup. Improvement in sample processing and analysis leads to increased laboratory capacity to handle the analysis of a large number of samples following the intentional or unintentional release of a radiological/nuclear contaminant.

  1. Infant discrimination of rapid auditory cues predicts later language impairment.

    PubMed

    Benasich, April A; Tallal, Paula

    2002-10-17

    The etiology and mechanisms of specific language impairment (SLI) in children are unknown. Differences in basic auditory processing abilities have been suggested to underlie their language deficits. Studies suggest that the neuropathology, such as atypical patterns of cerebral lateralization and cortical cellular anomalies, implicated in such impairments likely occur early in life. Such anomalies may play a part in the rapid processing deficits seen in this disorder. However, prospective, longitudinal studies in infant populations that are critical to examining these hypotheses have not been done. In the study described, performance on brief, rapidly-presented, successive auditory processing and perceptual-cognitive tasks were assessed in two groups of infants: normal control infants with no family history of language disorders and infants from families with a positive family history for language impairment. Initial assessments were obtained when infants were 6-9 months of age (M=7.5 months) and the sample was then followed through age 36 months. At the first visit, infants' processing of rapid auditory cues as well as global processing speed and memory were assessed. Significant differences in mean thresholds were seen in infants born into families with a history of SLI as compared with controls. Examination of relations between infant processing abilities and emerging language through 24 months-of-age revealed that threshold for rapid auditory processing at 7.5 months was the single best predictor of language outcome. At age 3, rapid auditory processing threshold and being male, together predicted 39-41% of the variance in language outcome. Thus, early deficits in rapid auditory processing abilities both precede and predict subsequent language delays. These findings support an essential role for basic nonlinguistic, central auditory processes, particularly rapid spectrotemporal processing, in early language development. Further, these findings provide a temporal diagnostic window during which future language impairments may be addressed.

  2. Rapid Radiochemical Analyses in Support of Fukushima Nuclear Accident - 13196

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    There is an increasing need to develop faster analytical methods for emergency response, including emergency soil and air filter samples [1, 2]. The Savannah River National Laboratory (SRNL) performed analyses on samples received from Japan in April, 2011 as part of a U.S. Department of Energy effort to provide assistance to the government of Japan, following the nuclear event at Fukushima Daiichi, resulting from the earthquake and tsunami on March 11, 2011. Of particular concern was whether it was safe to plant rice in certain areas (prefectures) near Fukushima. The primary objectives of the sample collection, sample analysis, and datamore » assessment teams were to evaluate personnel exposure hazards, identify the nuclear power plant radiological source term and plume deposition, and assist the government of Japan in assessing any environmental and agricultural impacts associated with the nuclear event. SRNL analyzed approximately 250 samples and reported approximately 500 analytical method determinations. Samples included soil from farmland surrounding the Fukushima reactors and air monitoring samples of national interest, including those collected at the U.S. Embassy and American military bases. Samples were analyzed for a wide range of radionuclides, including strontium-89, strontium-90, gamma-emitting radionuclides, and plutonium, uranium, americium and curium isotopes. Technical aspects of the rapid soil and air filter analyses will be described. The extent of radiostrontium contamination was a significant concern. For {sup 89,90}Sr analyses on soil samples, a rapid fusion technique using 1.5 gram soil aliquots to enable a Minimum Detectable Activity (MDA) of <1 pCi {sup 89,90}Sr /g of soil was employed. This sequential technique has been published recently by this laboratory for actinides and radiostrontium in soil and vegetation [3, 4]. It consists of a rapid sodium hydroxide fusion, pre-concentration steps using iron hydroxide and calcium fluoride precipitations, followed by Sr-Resin separation and gas flow proportional counting. To achieve a lower detection limit for analysis of some of the Japanese soil samples, a 10 gram aliquot of soil was taken, acid-leached and processed with similar preconcentration chemistry. The MDA using this approach was ∼0.03 pCi/g (1.1 mBq/g)/, which is less than the 0.05-0.10 pCi/g {sup 90}Sr levels found in soil as a result of global fallout. The chemical yields observed for the Japanese soil samples was typically 75-80% and the laboratory control sample (LCS) and matrix spike (MS) results looked very good for this work Individual QC results were well within the ± 25% acceptable range and the average of these results does not show significant bias. Additional data for a radiostrontium in soil method for 50 gram samples will also be presented, which appears to be a significant step forward based on looking at the current literature, with higher chemical yields for even larger sample aliquots and lower MDA [5, 6, 7] Hou et al surveyed a wide range of separation methods for Pu in waters and environmental solid samples [8]. While there are many actinide methods in the scientific literature, few would be considered rapid due to the tedious and time-consuming steps involved. For actinide analyses in soil, a new rapid method for the determination of actinide isotopes in soil samples using both alpha spectrometry and inductively-coupled plasma mass spectrometry was employed. The new rapid soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. [9, 10] Vacuum box technology and rapid flow rates were used to reduce analytical time. Challenges associated with the mineral content in the volcanic soil will be discussed. Air filter samples were reported within twenty-four (24) hours of receipt using rapid techniques published previously. [11] The rapid reporting of high quality analytical data arranged through the U.S. Department of Energy Consequence Management Home Team was critical to allow the government of Japan to readily evaluate radiological impacts from the nuclear reactor incident to both personnel and the environment. SRNL employed unique rapid methods capability for radionuclides to support Japan that can also be applied to environmental, bioassay and waste management samples. New rapid radiochemical techniques for radionuclides in soil and other environmental matrices as well as some of the unique challenges associated with this work will be presented that can be used for application to environmental monitoring, environmental remediation, decommissioning and decontamination activities. (authors)« less

  3. RAPID RADIOCHEMICAL ANALYSES IN SUPPORT OF FUKUSHIMA NUCLEAR ACCIDENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.

    2012-11-07

    There is an increasing need to develop faster analytical methods for emergency response, including emergency soil and air filter samples. The Savannah River National Laboratory (SRNL) performed analyses on samples received from Japan in April, 2011 as part of a U.S. Department of Energy effort to provide assistance to the government of Japan, following the nuclear event at Fukushima Daiichi, resulting from the earthquake and tsunami on March 11, 2011. Of particular concern was whether it was safe to plant rice in certain areas (prefectures) near Fukushima. The primary objectives of the sample collection, sample analysis, and data assessment teamsmore » were to evaluate personnel exposure hazards, identify the nuclear power plant radiological source term and plume deposition, and assist the government of Japan in assessing any environmental and agricultural impacts associated with the nuclear event. SRNL analyzed approximately 250 samples and reported approximately 500 analytical method determinations. Samples included soil from farmland surrounding the Fukushima reactors and air monitoring samples of national interest, including those collected at the U.S. Embassy and American military bases. Samples were analyzed for a wide range of radionuclides, including strontium-89, strontium-90, gamma-emitting radionuclides, and plutonium, uranium, americium and curium isotopes. Technical aspects of the rapid soil and air filter analyses will be described. The extent of radiostrontium contamination was a significant concern. For {sup 89,90}Sr analyses on soil samples, a rapid fusion technique using 1.5 gram soil aliquots to enable a Minimum Detectable Activity (MDA) of <1 pCi {sup 89,90} Sr /g of soil was employed. This sequential technique has been published recently by this laboratory for actinides and radiostrontium in soil and vegetation. It consists of a rapid sodium hydroxide fusion, pre-concentration steps using iron hydroxide and calcium fluoride precipitations, followed by Sr-Resin separation and gas flow proportional counting. To achieve a lower detection limit for analysis of some of the Japanese soil samples, a 10 gram aliquot of soil was taken, acid-leached and processed with similar preconcentration chemistry. The MDA using this approach was ~0.03 pCi/g (1.1 mBq/g)/, which is less than the 0.05-0.10 pCi/g {sup 90}Sr levels found in soil as a result of global fallout. The chemical yields observed for the Japanese soil samples was typically 75-80% and the laboratory control sample (LCS) and matrix spike (MS) results looked very good for this work Individual QC results were well within the ± 25% acceptable range and the average of these results does not show significant bias. Additional data for a radiostrontium in soil method for 50 gram samples will also be presented, which appears to be a significant step forward based on looking at the current literature, with higher chemical yields for even larger sample aliquots and lower MDA. Hou et al surveyed a wide range of separation methods for Pu in waters and environmental solid samples. While there are many actinide methods in the scientific literature, few would be considered rapid due to the tedious and time-consuming steps involved. For actinide analyses in soil, a new rapid method for the determination of actinide isotopes in soil samples using both alpha spectrometry and inductively-coupled plasma mass spectrometry was employed. The new rapid soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates were used to reduce analytical time. Challenges associated with the mineral content in the volcanic soil will be discussed. Air filter samples were reported within twenty-four (24) hours of receipt using rapid techniques published previously. The rapid reporting of high quality analytical data arranged through the U.S. Department of Energy Consequence Management Home Team was critical to allow the government of Japan to readily evaluate radiological impacts from the nuclear reactor incident to both personnel and the environment. SRNL employed unique rapid methods capability for radionuclides to support Japan that can also be applied to environmental, bioassay and waste management samples. New rapid radiochemical techniques for radionuclides in soil and other environmental matrices as well as some of the unique challenges associated with this work will be presented that can be used for application to environmental monitoring, environmental remediation, decommissioning and decontamination activities.« less

  4. Study on the applicability of a precise, accurate method for rapid evaluation of engine and lubricant performance. [determination of wear metal in used lubricating oils

    NASA Technical Reports Server (NTRS)

    Kinard, J. T.

    1975-01-01

    The development of a procedure for obtaining data related to wear metal determinations in used lubricants is discussed. The procedure makes it possible to obtain rapid, simultaneous determinations of a number of wear metals at levels of parts per thousand to low parts per billion using a small amount of sample. The electrode assembly and instrumentation used in the process are described. Samples of data obtained from tests conducted under controlled conditions are tabulated.

  5. Rapid identification of oral isolates of Aggregatibacter actinomycetemcomitans obtained from humans and primates by an ultrafast super convection based polymerase chain reaction

    PubMed Central

    Karched, M.; Furgang, D.; Sawalha, N.; Fine, D.H.

    2017-01-01

    Aggregatibacter actinomycetemcomitans is a Gram negative oral bacterium associated with localized aggressive periodontitis (LAP). Detection of A. actinomycetemcomitans in clinical samples is routinely done by PCR. Our aim was to develop a rapid and reliable PCR method that can be used as a chair-side tool to detect A. actinomycetemcomitans in clinical samples. Sensitivity and specificity assessment was performed on buccal and plaque samples obtained from 40 adolescents enrolled in an ongoing LAP study by comparing 20 A. actinomycetemcomitans-positive subjects and 20 who were negative. In a second study, A. actinomycetemcomitans presence was tested in oral samples from eighty-six primates that included rhesus monkeys, chimpanzees, marmosets, tamarins and baboons. All samples were processed for detection of A. actinomycetemcomitans by means of culture, conventional PCR (cPCR) and rapid PCR (rPCR) using a Super Convection based AmpXpress thermal cycler (AlphaHelix, Sweden). For human samples, culture, cPCR and rPCR showed perfect agreement. Using this method A. actinomycetemcomitans was detected in 27 of 32 rhesus monkeys, 4 of 8 chimpanzees and 1 of 34 marmosets. Rapidity of AmpXpress thermal cycler, combined with Ready-To-Go PCR beads (GE Life sciences), a quick DNA extraction kit (Epicentre Biotechnologies, Madison, Wisconsin, USA) and a bufferless fast agarose gel system, made it possible to obtain results on A. actinomycetemcomitans detection within 35 min. We conclude that AmpXpress fast PCR can be conveniently used as a chair-side tool for rapid detection of A. actinomycetemcomitans in clinical samples. PMID:22326236

  6. Integrated Multi-process Microfluidic Systems for Automating Analysis

    PubMed Central

    Yang, Weichun; Woolley, Adam T.

    2010-01-01

    Microfluidic technologies have been applied extensively in rapid sample analysis. Some current challenges for standard microfluidic systems are relatively high detection limits, and reduced resolving power and peak capacity compared to conventional approaches. The integration of multiple functions and components onto a single platform can overcome these separation and detection limitations of microfluidics. Multiplexed systems can greatly increase peak capacity in multidimensional separations and can increase sample throughput by analyzing many samples simultaneously. On-chip sample preparation, including labeling, preconcentration, cleanup and amplification, can all serve to speed up and automate processes in integrated microfluidic systems. This paper summarizes advances in integrated multi-process microfluidic systems for automated analysis, their benefits and areas for needed improvement. PMID:20514343

  7. Rapid production of hollow SS316 profiles by extrusion based additive manufacturing

    NASA Astrophysics Data System (ADS)

    Rane, Kedarnath; Cataldo, Salvatore; Parenti, Paolo; Sbaglia, Luca; Mussi, Valerio; Annoni, Massimiliano; Giberti, Hermes; Strano, Matteo

    2018-05-01

    Complex shaped stainless steel tubes are often required for special purpose biomedical equipment. Nevertheless, traditional manufacturing technologies, such as extrusion, lack the ability to compete in a market of customized complex components because of associated expenses towards tooling and extrusion presses. To rapid manufacture few of such components with low cost and high precision, a new Extrusion based Additive Manufacturing (EAM) process, is proposed in this paper, and as an example, short stainless steel 316L complex shaped and sectioned tubes were prepared by EAM. Several sample parts were produced using this process; the dimensional stability, surface roughness and chemical composition of sintered samples were investigated to prove process competence. The results indicate that feedstock with a 316L particle content of 92.5 wt. % can be prepared with a sigma blade mixing, whose rheological behavior is fit for EAM. The green samples have sufficient strength to handle them for subsequent treatments. The sintered samples considerably shrunk to designed dimensions and have a homogeneous microstructure to impart mechanical strength. Whereas, maintaining comparable dimensional accuracy and chemical composition which are required for biomedical equipment still need iterations, a kinematic correction and modification in debinding cycle was proposed.

  8. Rapid-viability PCR method for detection of live, virulent Bacillus anthracis in environmental samples.

    PubMed

    Létant, Sonia E; Murphy, Gloria A; Alfaro, Teneile M; Avila, Julie R; Kane, Staci R; Raber, Ellen; Bunt, Thomas M; Shah, Sanjiv R

    2011-09-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples.

  9. Musical Experience, Sensorineural Auditory Processing, and Reading Subskills in Adults.

    PubMed

    Tichko, Parker; Skoe, Erika

    2018-04-27

    Developmental research suggests that sensorineural auditory processing, reading subskills (e.g., phonological awareness and rapid naming), and musical experience are related during early periods of reading development. Interestingly, recent work suggests that these relations may extend into adulthood, with indices of sensorineural auditory processing relating to global reading ability. However, it is largely unknown whether sensorineural auditory processing relates to specific reading subskills, such as phonological awareness and rapid naming, as well as musical experience in mature readers. To address this question, we recorded electrophysiological responses to a repeating click (auditory stimulus) in a sample of adult readers. We then investigated relations between electrophysiological responses to sound, reading subskills, and musical experience in this same set of adult readers. Analyses suggest that sensorineural auditory processing, reading subskills, and musical experience are related in adulthood, with faster neural conduction times and greater musical experience associated with stronger rapid-naming skills. These results are similar to the developmental findings that suggest reading subskills are related to sensorineural auditory processing and musical experience in children.

  10. Development and validation of the RapidHIT™ 200 utilising NGMSElect™ Express for the processing of buccal swabs.

    PubMed

    Shackleton, David; Pagram, Jenny; Ives, Lesley; Vanhinsbergh, Des

    2018-06-02

    The RapidHIT™ 200 System is a fully automated sample-to-DNA profile system designed to produce high quality DNA profiles within 2h. The use of RapidHIT™ 200 System within the United Kingdom Criminal Justice System (UKCJS) has required extensive development and validation of methods with a focus on AmpFℓSTR ® NGMSElect™ Express PCR kit to comply with specific regulations for loading to the UK National DNA Database (NDNAD). These studies have been carried out using single source reference samples to simulate live reference samples taken from arrestees and victims for elimination. The studies have shown that the system is capable of generating high quality profile and has achieved the accreditations necessary to load to the NDNAD; a first for the UK. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Microstructures and properties of rapidly solidified alloys

    NASA Technical Reports Server (NTRS)

    Shechtman, D.; Horowitz, E.

    1984-01-01

    The microstructure and properties of rapidly solidified aluminum alloys were researched. The effects of powder and flake chemistry and morphology and alternative consolidation processing parameters are being conducted. Samples of the powders being utilized were obtained for comprehensive metallurgical characterization. Seven aluminum alloys in the form of thin foils were studied by a variety of techniques including optical metallography, scanning electron microscope, and transmission electron microscope. Details of the microstructural characteristics are presented along with a discussion of the solidification process. A better understanding of the microstructure of the rapidly solidified aluminum alloys prepared by a variety of techniques such as roller quenching, the vacuum atomized procedure, ultrasonically atomized in inert atmospheres, and atomized in flue gas was provided.

  12. Aspects of the tribological behaviour of powders recycled from rapid steel treated sub-zero

    NASA Astrophysics Data System (ADS)

    Radu, S.; Ciobanu, M.

    2017-02-01

    The recycling of high-alloyed steels represents a significant opportunity in Powder Metallurgy as it permits the use of raw materials with relatively low prices compared to the conventional methods. Recycling can be achieved by two methods: from spraying debris resulted from worn cutting tools and processes obtained from processing chip drilling and re-sharpening of tools. The research aims to confirm that wastes from rapid steels can become, by the successive processing, metal powders that can thereafter be used for cutting tools of lathe type removable plate. After pressing and sintering the recycling powder, cylindrical samples were obtained that were subsequently applied a subcritical annealing. Wear tests conducted on a tribometer type TRB-01-02541 confirmed that their wear resistance is superior to the same samples that were sintered, hardened and tempered in oil. This paper was accepted for publication in Proceedings after double peer reviewing process but was not presented at the Conference ROTRIB’16.

  13. A study of reduced chromium content in a nickel-base superalloy via element substitution and rapid solidification processing. Ph.D. ThesisFinal Report

    NASA Technical Reports Server (NTRS)

    Powers, William O.

    1987-01-01

    A study of reduced chromium content in a nickel base superalloy via element substitution and rapid solidification processing was performed. The two elements used as partial substitutes for chromium were Si and Zr. The microstructure of conventionally solidified materials was characterized using microscopy techniques. These alloys were rapidly solidified using the chill block melt spinning technique and the rapidly solidified microstructures were characterized using electron microscopy. The spinning technique and the rapidly solidified microstructures was assessed following heat treatments at 1033 and 1272 K. Rapidly solidified material of three alloys was reduced to particulate form and consolidated using hot isostatic pressing (HIP). The consolidated materials were also characterized using microscopy techniques. In order to evaluate the relative strengths of the consolidated alloys, compression tests were performed at room temperature and 1033 K on samples of as-HIPed and HIPed plus solution treated material. Yield strength, porosity, and oxidation resistance characteristics are given and compared.

  14. REAL TIME MONITORING OF PCDD/PCDF FOR TRANSIENT CHARACTERIZATION AND PROCESS CONTROL

    EPA Science Inventory

    Current sampling methods for PCDD/F emission compliance make use of a sample taken during steady state conditions which is assumed to be representative of facility performance. This is often less than satisfactory. The rapid variation of PCDDs, PCDF, and other co-pollutants due ...

  15. Rapid separation and purification of uranium and plutonium from dilute-matrix samples

    DOE PAGES

    Armstrong, Christopher R.; Ticknor, Brian W.; Hall, Gregory; ...

    2014-03-11

    This work presents a streamlined separation and purification approach for trace uranium and plutonium from dilute (carrier-free) matrices. The method, effective for nanogram quantities of U and femtogram to picogram quantities of Pu, is ideally suited for environmental swipe samples that contain a small amount of collected bulk material. As such, it may be applicable for processing swipe samples such as those collected in IAEA inspection activities as well as swipes that are loaded with unknown analytes, such as those implemented in interlaboratory round-robin or proficiency tests. Additionally, the simplified actinide separation could find use in internal laboratory monitoring ofmore » clean room conditions prior to or following more extensive chemical processing. We describe key modifications to conventional techniques that result in a relatively rapid, cost-effective, and efficient U and Pu separation process. We demonstrate the efficacy of implementing anion exchange chromatography in a single column approach. We also show that hydrobromic acid is an effective substitute in lieu of hydroiodoic acid for eluting Pu. Lastly, we show that nitric acid is an effective digestion agent in lieu of perchloric acid and/or hydrofluoric acid. A step by step procedure of this process is detailed.« less

  16. A Direct and Rapid Method to Determine Cyanide in Urine by Capillary Electrophoresis

    PubMed Central

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-01-01

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4 minutes, and the separation was observed in 25 s. The limit of detection (LOD) was 4.0 nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification. PMID:26342870

  17. [Automated RNA amplification for the rapid identification of Mycobacterium tuberculosis complex in respiratory specimens].

    PubMed

    Drouillon, V; Houriez, F; Buze, M; Lagrange, P; Herrmann, J-L

    2006-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis complex (MTB) directly on clinical respiratory specimens is essential for a correct management of patients suspected of tuberculosis. For this purpose PCR-based kits are available to detect MTB in respiratory specimen but most of them need at least 4 hours to be completed. New methods, based on TRC method (TRC: Transcription Reverse transcription Concerted--TRCRapid M. Tuberculosis--Tosoh Bioscience, Tokyo, Japon) and dedicated monitor have been developed. A new kit (TRC Rapid M. tuberculosis and Real-time monitor TRCRapid-160, Tosoh Corporation, Japan) enabling one step amplification and real-time detection of MTB 16S rRNA by a combination of intercalative dye oxazole yellow-linked DNA probe and isothermal RNA amplification directly on respiratory specimens has been tested in our laboratory. 319 respiratory specimens were tested in this preliminary study and results were compared to smear and culture. Fourteen had a positive culture for MTB. Among theses samples, smear was positive in 11 cases (78.6%) and TRC process was positive in 8 cases (57.1%). Overall sensitivity of TRC compared to smear positive samples is 73%. Theses first results demonstrated that a rapid identification of MTB was possible (less than 2 processing hours for 14 specimens and about 1 hour for 1 specimen) in most cases of smear positive samples using ready to use reagents for real time detection of MTB rRNA in clinical samples. New pretreatment and extraction reagents kits to increase the stability of the sputum RNA and the extraction efficiency are now tested in our laboratory.

  18. Operation of a sampling train for the analysis of environmental species in coal gasification gas-phase process streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pochan, M.J.; Massey, M.J.

    1979-02-01

    This report discusses the results of actual raw product gas sampling efforts and includes: Rationale for raw product gas sampling efforts; design and operation of the CMU gas sampling train; development and analysis of a sampling train data base; and conclusions and future application of results. The results of sampling activities at the CO/sub 2/-Acceptor and Hygas pilot plants proved that: The CMU gas sampling train is a valid instrument for characterization of environmental parameters in coal gasification gas-phase process streams; depending on the particular process configuration, the CMU gas sampling train can reduce gasifier effluent characterization activity to amore » single location in the raw product gas line; and in contrast to the slower operation of the EPA SASS Train, CMU's gas sampling train can collect representative effluent data at a rapid rate (approx. 2 points per hour) consistent with the rate of change of process variables, and thus function as a tool for process engineering-oriented analysis of environmental characteristics.« less

  19. Gross alpha and beta activity analyses in urine-a routine laboratory method for internal human radioactivity detection.

    PubMed

    Chen, Xiaowen; Zhao, Luqian; Qin, Hongran; Zhao, Meijia; Zhou, Yirui; Yang, Shuqiang; Su, Xu; Xu, Xiaohua

    2014-05-01

    The aim of this work was to develop a method to provide rapid results for humans with internal radioactive contamination. The authors hypothesized that valuable information could be obtained from gas proportional counter techniques by screening urine samples from potentially exposed individuals rapidly. Recommended gross alpha and beta activity screening methods generally employ gas proportional counting techniques. Based on International Standards Organization (ISO) methods, improvements were made in the evaporation process to develop a method to provide rapid results, adequate sensitivity, and minimum sample preparation and operator intervention for humans with internal radioactive contamination. The method described by an American National Standards Institute publication was used to calibrate the gas proportional counter, and urine samples from patients with or without radionuclide treatment were measured to validate the method. By improving the evaporation process, the time required to perform the assay was reduced dramatically. Compared with the reference data, the results of the validation samples were very satisfactory with respect to gross-alpha and gross-beta activities. The gas flow proportional counting method described here has the potential for radioactivity monitoring in the body. This method was easy, efficient, and fast, and its application is of great utility in determining whether a sample should be analyzed by a more complicated method, for example radiochemical and/or γ-spectroscopy. In the future, it may be used commonly in medical examination and nuclear emergency treatment.Health Phys. 106(5):000-000; 2014.

  20. Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width.

    PubMed

    De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher

    2015-12-01

    Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width . We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates , which have bounded hierarchy width-regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers.

  1. Rapid Microcystin Determination Using a Paper Spray Ionization Method with a Time-of-Flight Mass Spectrometry System.

    PubMed

    Zhu, Xiaoqiang; Huang, Zhengxu; Gao, Wei; Li, Xue; Li, Lei; Zhu, Hui; Mo, Ting; Huang, Bao; Zhou, Zhen

    2016-07-13

    The eutrophication of surface water sources and climate changes have resulted in an annual explosion of cyanobacterial blooms in many irrigating and drinking water resources. To decrease health risks to the public, a rapid real time method for the synchronous determination of two usually harmful microcystins (MC-RR and MC-LR) in environmental water samples was built by employing a paper spray ionization method coupled with a time-of-flight mass spectrometer system. With this approach, direct analysis of microcystin mixtures without sample preparation has been achieved. Rapid detection was performed, simulating the release process of microcystins in reservoir water samples, and the routine detection frequency was every three minutes. The identification time of microcystins was reduced from several hours to a few minutes. The limit of detection is 1 μg/L, and the limit of quantitation is 3 μg/L. This method displays the ability for carrying out rapid, direct, and high-throughput experiments for determination of microcystins, and it would be of significant interest for environmental and food safety applications.

  2. Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection

    PubMed Central

    Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan

    2011-01-01

    Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O2 content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. PMID:21497566

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    A new rapid fusion method for the determination of plutonium in large rice samples has been developed at the Savannah River National Laboratory (Aiken, SC, USA) that can be used to determine very low levels of plutonium isotopes in rice. The recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid, reliable radiochemical analyses for radionuclides in environmental and food samples. Public concern regarding foods, particularly foods such as rice in Japan, highlights the need for analytical techniques that will allow very large sample aliquots of rice to be used for analysis so thatmore » very low levels of plutonium isotopes may be detected. The new method to determine plutonium isotopes in large rice samples utilizes a furnace ashing step, a rapid sodium hydroxide fusion method, a lanthanum fluoride matrix removal step, and a column separation process with TEVA Resin cartridges. The method can be applied to rice sample aliquots as large as 5 kg. Plutonium isotopes can be determined using alpha spectrometry or inductively-coupled plasma mass spectrometry (ICP-MS). The method showed high chemical recoveries and effective removal of interferences. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory plutonium particles are effectively digested. The MDA for a 5 kg rice sample using alpha spectrometry is 7E-5 mBq g{sup -1}. The method can easily be adapted for use by ICP-MS to allow detection of plutonium isotopic ratios.« less

  4. Fiber-Coupled Acousto-Optical-Filter Spectrometer

    NASA Technical Reports Server (NTRS)

    Levin, Kenneth H.; Li, Frank Yanan

    1993-01-01

    Fiber-coupled acousto-optical-filter spectrometer steps rapidly through commanded sequence of wavelengths. Sample cell located remotely from monochromator and associated electronic circuitry, connected to them with optical fibers. Optical-fiber coupling makes possible to monitor samples in remote, hazardous, or confined locations. Advantages include compactness, speed, and no moving parts. Potential applications include control of chemical processes, medical diagnoses, spectral imaging, and sampling of atmospheres.

  5. NASA MSFC Electrostatic Levitator (ESL) Rapid Quench System

    NASA Technical Reports Server (NTRS)

    SanSoucie, Michael P.; Craven, Paul D.

    2014-01-01

    Electrostatic levitation, a form of containerless processing, is an important tool in materials research. Levitated specimens are free from contact with a container; therefore, heterogeneous nucleation on container walls is not possible. This allows studies of deeply undercooled melts. Furthermore, studies of high-temperature, highly reactive materials are also possible. Studies of the solidification and crystallization of undercooled melts is vital to the understanding of microstructure development, particularly the formation of alloys with unique properties by rapid solidification. The NASA Marshall Space Flight Center (MSFC) Electrostatic Levitator (ESL) lab has recently been upgraded to allow for rapid quenching of levitated materials. The ESL Rapid Quench System uses a small crucible-like vessel that can be partially filled with a low melting point material, such as a Gallium alloy, as a quench medium. An undercooled sample can be dropped into the vessel to rapidly quench the sample. A carousel with nine vessels sits below the bottom electrode assembly. This system allows up to nine rapid quenches before having to break vacuum and remove the vessels. This new Rapid Quench System will allow materials science studies of undercooled materials and new materials development. In this presentation, the system is described and initial results are presented.

  6. Rapid-Viability PCR Method for Detection of Live, Virulent Bacillus anthracis in Environmental Samples ▿

    PubMed Central

    Létant, Sonia E.; Murphy, Gloria A.; Alfaro, Teneile M.; Avila, Julie R.; Kane, Staci R.; Raber, Ellen; Bunt, Thomas M.; Shah, Sanjiv R.

    2011-01-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples. PMID:21764960

  7. Microgravity

    NASA Image and Video Library

    2004-04-15

    Comparison of ground-based (left) and Skylab (right) electron beam welds in pure tantalum (Ta) (10X magnification). Residual votices left behind in the ground-based sample after the electron beam passed were frozen into the grain structure. These occurred because of the rapid cooling rate at the high temperature. Although the thermal characteristics and electron beam travel speeds were comparable for the skylab sample, the residual vortices were erased in the grain structure. This may have been due to the fact that final grain size of the solidified material was smaller in the Skylab sample compared to the ground-based sample. The Skylab sample was processed in the M512 Materials Processing Facility (MPF) during Skylab SL-2 Mission. Principal Investigator was Richard Poorman.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egorov, Oleg; O'Hara, Matthew J.; Grate, Jay W.

    An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed amore » preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.« less

  9. Can the use of pulsed direct current induce oscillation in the applied pressure during spark plasma sintering?

    PubMed Central

    Salamon, David; Eriksson, Mirva; Nygren, Mats; Shen, Zhijian

    2012-01-01

    The spark plasma sintering (SPS) process is known for its rapid densification of metals and ceramics. The mechanism behind this rapid densification has been discussed during the last few decades and is yet uncertain. During our SPS experiments we noticed oscillations in the applied pressure, related to a change in electric current. In this study, we investigated the effect of pulsed electrical current on the applied mechanical pressure and related changes in temperature. We eliminated the effect of sample shrinkage in the SPS setup and used a transparent quartz die allowing direct observation of the sample. We found that the use of pulsed direct electric current in our apparatus induces pressure oscillations with the amplitude depending on the current density. While sintering Ti samples we observed temperature oscillations resulting from pressure oscillations, which we attribute to magnetic forces generated within the SPS apparatus. The described current–pressure–temperature relations might increase understanding of the SPS process. PMID:27877472

  10. Evaluation of a rapid method for measurement of catalase activity in cooked beef and sausage.

    PubMed

    Davis, C E; Cyrus, S

    1998-02-01

    Catalase (CAT) activity in ground beef and pork was determined on samples cooked from 60 to 71.1 degrees C. One-gram samples of ground round (4% fat), hamburger (24% fat), and commercial pork sausage (38%fat) were cooked in a controlled-temperature waterbath at 65, 68.3 and 71 degrees C. Chilled samples were immersed in direct contact with the cooking water; the test samples were removed every 15 s and immediately immersed in an ice-water bath (O to 1 degrees C) to quick-chill the samples to prevent temperature over-run. Samples retained high (HMB value 20+, over range) CAT activity through 90, 60, and 45 s at 65, 68.3, and 71 degrees C, respectively, before showing rapid activity decreases. Four USDA-FSIS approved meat patty heating processes (66.1 degrees C, 41 s; 67.2 degrees C, 26 s; 68.3 degrees C, 16 s; and 69.4 degrees C, 10 s) were analyzed for CAT activity in meat frozen prior to cooking was slightly lower (P < 0.05) than in degrees C meat. CAT activity decreased (P < 0.05) among meat treated at 66.1 degrees C for 41 s, at 67.2 degrees C for 26 s, and at 68.3 degrees C for 16 s, but the treatment at 68.3 degrees C for 16 s was not different (P < 0.05) from that at 69.4 degrees C for 10 s. These results show this rapid (20 to 25 min) CAT activity test could be used to establish activity values at specific end-point temperatures for model heat-processed ground beef or sausage products and may be useful to USDA FSIS process inspectors and food processors in quality assurance and HACCP (hazard analysis critical control points) programs for thermal input verification.

  11. Metabolic profiling of body fluids and multivariate data analysis.

    PubMed

    Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten

    2017-01-01

    Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.

  12. A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

    PubMed

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-10-02

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4min, and the separation was observed in 25s. The limit of detection (LOD) was 4.0nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification. Published by Elsevier B.V.

  13. Musical Experience, Sensorineural Auditory Processing, and Reading Subskills in Adults

    PubMed Central

    Tichko, Parker; Skoe, Erika

    2018-01-01

    Developmental research suggests that sensorineural auditory processing, reading subskills (e.g., phonological awareness and rapid naming), and musical experience are related during early periods of reading development. Interestingly, recent work suggests that these relations may extend into adulthood, with indices of sensorineural auditory processing relating to global reading ability. However, it is largely unknown whether sensorineural auditory processing relates to specific reading subskills, such as phonological awareness and rapid naming, as well as musical experience in mature readers. To address this question, we recorded electrophysiological responses to a repeating click (auditory stimulus) in a sample of adult readers. We then investigated relations between electrophysiological responses to sound, reading subskills, and musical experience in this same set of adult readers. Analyses suggest that sensorineural auditory processing, reading subskills, and musical experience are related in adulthood, with faster neural conduction times and greater musical experience associated with stronger rapid-naming skills. These results are similar to the developmental findings that suggest reading subskills are related to sensorineural auditory processing and musical experience in children. PMID:29702572

  14. In situ experimental formation and growth of Fe nanoparticles and vesicles in lunar soil

    NASA Astrophysics Data System (ADS)

    Thompson, Michelle S.; Zega, Thomas J.; Howe, Jane Y.

    2017-03-01

    We report the results of the first dynamic, in situ heating of lunar soils to simulate micrometeorite impacts on the lunar surface. We performed slow- and rapid-heating experiments inside the transmission electron microscope to understand the chemical and microstructural changes in surface soils resulting from space-weathering processes. Our slow-heating experiments show that the formation of Fe nanoparticles begins at 575 °C. These nanoparticles also form as a result of rapid-heating experiments, and electron energy-loss spectroscopy measurements indicate the Fe nanoparticles are composed entirely of Fe0, suggesting this simulation accurately mimics micrometeorite space-weathering processes occurring on airless body surfaces. In addition to Fe nanoparticles, rapid-heating experiments also formed vesiculated textures in the samples. Several grains were subjected to repeated thermal shocks, and the measured size distribution and number of Fe nanoparticles evolved with each subsequent heating event. These results provide insight into the formation and growth mechanisms for Fe nanoparticles in space-weathered soils and could provide a new methodology for relative age dating of individual soil grains from within a sample population.

  15. Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width

    PubMed Central

    De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher

    2016-01-01

    Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width. We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates, which have bounded hierarchy width—regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers. PMID:27279724

  16. Improvement of High-throughput Genotype Analysis After Implementation of a Dual-curve Sybr Green I-based Quantification and Normalization Procedure

    USDA-ARS?s Scientific Manuscript database

    The ability to rapidly screen a large number of individuals is the key to any successful plant breeding program. One of the primary bottlenecks in high throughput screening is the preparation of DNA samples, particularly the quantification and normalization of samples for downstream processing. A ...

  17. Exploiting machine learning algorithms for tree species classification in a semiarid woodland using RapidEye image

    NASA Astrophysics Data System (ADS)

    Adelabu, Samuel; Mutanga, Onisimo; Adam, Elhadi; Cho, Moses Azong

    2013-01-01

    Classification of different tree species in semiarid areas can be challenging as a result of the change in leaf structure and orientation due to soil moisture constraints. Tree species mapping is, however, a key parameter for forest management in semiarid environments. In this study, we examined the suitability of 5-band RapidEye satellite data for the classification of five tree species in mopane woodland of Botswana using machine leaning algorithms with limited training samples.We performed classification using random forest (RF) and support vector machines (SVM) based on EnMap box. The overall accuracies for classifying the five tree species was 88.75 and 85% for both SVM and RF, respectively. We also demonstrated that the new red-edge band in the RapidEye sensor has the potential for classifying tree species in semiarid environments when integrated with other standard bands. Similarly, we observed that where there are limited training samples, SVM is preferred over RF. Finally, we demonstrated that the two accuracy measures of quantity and allocation disagreement are simpler and more helpful for the vast majority of remote sensing classification process than the kappa coefficient. Overall, high species classification can be achieved using strategically located RapidEye bands integrated with advanced processing algorithms.

  18. Impact of deploying multiple point-of-care tests with a 'sample first' approach on a sexual health clinical care pathway. A service evaluation.

    PubMed

    Harding-Esch, Emma M; Nori, Achyuta V; Hegazi, Aseel; Pond, Marcus J; Okolo, Olanike; Nardone, Anthony; Lowndes, Catherine M; Hay, Phillip; Sadiq, S Tariq

    2017-09-01

    To assess clinical service value of STI point-of-care test (POCT) use in a 'sample first' clinical pathway (patients providing samples on arrival at clinic, before clinician consultation). Specific outcomes were: patient acceptability; whether a rapid nucleic acid amplification test (NAAT) for Chlamydia trachomatis/Neisseria gonorrhoeae (CT/NG) could be used as a POCT in practice; feasibility of non-NAAT POCT implementation for Trichomonas vaginalis (TV) and bacterial vaginosis (BV); impact on patient diagnosis and treatment. Service evaluation in a south London sexual health clinic. Symptomatic female and male patients and sexual contacts of CT/NG-positive individuals provided samples for diagnostic testing on clinic arrival, prior to clinical consultation. Tests included routine culture and microscopy; CT/NG (GeneXpert) NAAT; non-NAAT POCTs for TV and BV. All 70 (35 males, 35 females) patients approached participated. The 'sample first' pathway was acceptable, with >90% reporting they were happy to give samples on arrival and receive results in the same visit. Non-NAAT POCT results were available for all patients prior to leaving clinic; rapid CT/NG results were available for only 21.4% (15/70; 5 males, 10 females) of patients prior to leaving clinic. Known negative CT/NG results led to two females avoiding presumptive treatment, and one male receiving treatment directed at possible Mycoplasma genitalium infection causing non-gonococcal urethritis. Non-NAAT POCTs detected more positives than routine microscopy (TV 3 vs 2; BV 24 vs 7), resulting in more patients receiving treatment. A 'sample first' clinical pathway to enable multiple POCT use was acceptable to patients and feasible in a busy sexual health clinic, but rapid CT/NG processing time was too long to enable POCT use. There is need for further development to improve test processing times to enable POC use of rapid NAATs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection.

    PubMed

    Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan

    2011-06-01

    Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O(2) content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Collection, transport and general processing of clinical specimens in Microbiology laboratory.

    PubMed

    Sánchez-Romero, M Isabel; García-Lechuz Moya, Juan Manuel; González López, Juan José; Orta Mira, Nieves

    2018-02-06

    The interpretation and the accuracy of the microbiological results still depend to a great extent on the quality of the samples and their processing within the Microbiology laboratory. The type of specimen, the appropriate time to obtain the sample, the way of sampling, the storage and transport are critical points in the diagnostic process. The availability of new laboratory techniques for unusual pathogens, makes necessary the review and update of all the steps involved in the processing of the samples. Nowadays, the laboratory automation and the availability of rapid techniques allow the precision and turn-around time necessary to help the clinicians in the decision making. In order to be efficient, it is very important to obtain clinical information to use the best diagnostic tools. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  1. Evaluation of a new T2 Magnetic Resonance assay for rapid detection of emergent fungal pathogen Candida auris on clinical skin swab samples.

    PubMed

    Sexton, D Joseph; Bentz, Meghan L; Welsh, Rory M; Litvintseva, Anastasia P

    2018-06-25

    Candida auris is a multidrug-resistant pathogenic yeast whose recent emergence is of increasing public-health concern. C. auris can colonize multiple body sites, including patients' skin, and survive for weeks in the healthcare environment, facilitating patient-to-patient transmission and fueling healthcare-associated outbreaks. Rapid and accurate detection of C. auris colonization is essential for timely implementation of infection control measures and prevent transmission. Currently, axilla/groin composite swabs, used to assess colonization status, are processed using a culture-based method that is sensitive and specific but requires 14 days. This delay limits the opportunity to respond and highlights the need for a faster alternative. The culture-independent T2 Magnetic Resonance (T2MR) system is a rapid diagnostic platform shown to detect target pathogens of interest from unprocessed blood samples in <5 hours. In this study, a new C. auris-specific T2 assay was evaluated for screening of the skin surveillance samples. Inclusivity and limit of detection of the T2 C. auris assay were assessed with spiked samples in a representative skin flora background. The T2 C. auris assay recognized isolates from each of the 4 known clades of C. auris and consistently detected cells at 5 CFU/mL. Finally, 89 clinical axilla/groin swab samples were processed with the T2 C. auris assay. The culture-based diagnostic assay was used as a gold standard to determine performance statistics including sensitivity (0.89) and specificity (0.98). Overall, the T2 C. auris assay performed well as a rapid diagnostic and could help expedite the detection of C. auris in patient skin swabs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  2. Rapid microwave assisted synthesis of YIn1-xMnxO3 blue pigments: Synthesis, microstructure and optical properties

    NASA Astrophysics Data System (ADS)

    Zhou, Yuncheng; Jiang, Peng; Kuang, Jianlei; Yang, Xueshan; Cao, Wenbin

    2018-07-01

    The YIn1-xMnxO3 (0.1 ≤x ≤ 0.5) blue pigment samples are successfully prepared through a sol-gel process followed by microwave assisted sintering process. All the samples are shown single phases in the X-ray diffraction results. In the morphology study from scanning electronic microscope, the samples are composed of loosely connected small particles. The oxidation state of Mn is confirmed to be 3 + from the results of X-ray photonelectronic scan. The optical properties are characterized by UV-Visible spectrum and UV-visible-NIR spectrum. The samples exhibit intense blue color and they show small absorption in infrared region.

  3. Rapid fusion method for the determination of Pu, Np, and Am in large soil samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; ...

    2015-02-14

    A new rapid sodium hydroxide fusion method for the preparation of 10-20 g soil samples has been developed by the Savannah River National Laboratory (SRNL). The method enables lower detection limits for plutonium, neptunium, and americium in environmental soil samples. The method also significantly reduces sample processing time and acid fume generation compared to traditional soil digestion techniques using hydrofluoric acid. Ten gram soil aliquots can be ashed and fused using the new method in 1-2 hours, completely dissolving samples, including refractory particles. Pu, Np and Am are separated using stacked 2mL cartridges of TEVA and DGA Resin and measuredmore » using alpha spectrometry. The method can be adapted for measurement by inductively-coupled plasma mass spectrometry (ICP-MS). Two 10 g soil aliquots of fused soil may be combined prior to chromatographic separations to further improve detection limits. Total sample preparation time, including chromatographic separations and alpha spectrometry source preparation, is less than 8 hours.« less

  4. On-site identification of meat species in processed foods by a rapid real-time polymerase chain reaction system.

    PubMed

    Furutani, Shunsuke; Hagihara, Yoshihisa; Nagai, Hidenori

    2017-09-01

    Correct labeling of foods is critical for consumers who wish to avoid a specific meat species for religious or cultural reasons. Therefore, gene-based point-of-care food analysis by real-time Polymerase Chain Reaction (PCR) is expected to contribute to the quality control in the food industry. In this study, we perform rapid identification of meat species by our portable rapid real-time PCR system, following a very simple DNA extraction method. Applying these techniques, we correctly identified beef, pork, chicken, rabbit, horse, and mutton in processed foods in 20min. Our system was sensitive enough to detect the interfusion of about 0.1% chicken egg-derived DNA in a processed food sample. Our rapid real-time PCR system is expected to contribute to the quality control in food industries because it can be applied for the identification of meat species, and future applications can expand its functionality to the detection of genetically modified organisms or mutations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Addleman, Raymond S.; Naes, Benjamin E.; McNamara, Bruce K.

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmentalmore » sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2F 2 and UO 2(NO 3) 2, U 3O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.« less

  6. Evaluation of Sampling Methods for Bacillus Spore ...

    EPA Pesticide Factsheets

    Journal Article Following a wide area release of biological materials, mapping the extent of contamination is essential for orderly response and decontamination operations. HVAC filters process large volumes of air and therefore collect highly representative particulate samples in buildings. HVAC filter extraction may have great utility in rapidly estimating the extent of building contamination following a large-scale incident. However, until now, no studies have been conducted comparing the two most appropriate sampling approaches for HVAC filter materials: direct extraction and vacuum-based sampling.

  7. [Application of near-infrared spectroscopy technology in extraction and concentration process of Reduning injection].

    PubMed

    Zhang, Ya-Fei; Zuo, Xiang-Yun; Bi, Yu-An; Wu, Jian-Xiong; Wang, Zhen-Zhong; L, Ping; Xiao, Wei

    2014-08-01

    To establish a rapid quantitative analysis method for the content of chlorogenic acid and solid content in the extraction liquid concentration process during the production of Reduning injection by using the near-infrared (NIR) spectroscopy, in order to reflect the concentration state in a real-time manner and really realize the quality control of concentrating process of the extraction and concentration process. The samples during the Jinqing extraction liquid concentration process were collected. After the removal of abnormal samples, the spectra pretreatment and the wave band selection, the quantitative calibration model between NIR spectra and chlorogenic acid HPLC analytical value and solid content was established by using PLS algorithm, and unknown samples were predicted. The correlation coefficients between the chlorogenic acid content and the solid content were respectively 0.992 1 and 0.994 0, and the correlation coefficients of the verification model were respectively 0.994 4 and 0.998 4, with the root mean square error of calibration (RMSEC) of 0.814 6 and 2.656 1 and the root mean square error of prediction (RMSEP) of 0.704 6 and 1.876 7 respectively, and the relative standard errors of predictions (RSEP) were 6.01% and 2.93% respectively. The method is simple, rapid, nondestructive, accurate and reliable, thus could be adopted for the fast monitoring of the chlorogenic acid content and the solid content during the concentration process of Reduning injection extraction liquid.

  8. Most Probable Number Rapid Viability PCR Method to Detect Viable Spores of Bacillus anthracis in Swab Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Letant, S E; Kane, S R; Murphy, G A

    2008-05-30

    This note presents a comparison of Most-Probable-Number Rapid Viability (MPN-RV) PCR and traditional culture methods for the quantification of Bacillus anthracis Sterne spores in macrofoam swabs generated by the Centers for Disease Control and Prevention (CDC) for a multi-center validation study aimed at testing environmental swab processing methods for recovery, detection, and quantification of viable B. anthracis spores from surfaces. Results show that spore numbers provided by the MPN RV-PCR method were in statistical agreement with the CDC conventional culture method for all three levels of spores tested (10{sup 4}, 10{sup 2}, and 10 spores) even in the presence ofmore » dirt. In addition to detecting low levels of spores in environmental conditions, the MPN RV-PCR method is specific, and compatible with automated high-throughput sample processing and analysis protocols.« less

  9. Internal validation of the RapidHIT® ID system.

    PubMed

    Wiley, Rachel; Sage, Kelly; LaRue, Bobby; Budowle, Bruce

    2017-11-01

    Traditionally, forensic DNA analysis has required highly skilled forensic geneticists in a dedicated laboratory to generate short tandem repeat (STR) profiles. STR profiles are routinely used either to associate or exclude potential donors of forensic biological evidence. The typing of forensic reference samples has become more demanding, especially with the requirement in some jurisdictions to DNA profile arrestees. The Rapid DNA (RDNA) platform, the RapidHIT ® ID (IntegenX ® , Pleasanton, CA), is a fully automated system capable of processing reference samples in approximately 90min with minimal human intervention. Thus, the RapidHIT ID instrument can be deployed to non-laboratory environments (e.g., booking stations) and run by trained atypical personnel such as law enforcement. In order to implement the RapidHIT ID platform, validation studies are needed to define the performance and limitations of the system. Internal validation studies were undertaken with four early-production RapidHIT ID units. Reliable and concordant STR profiles were obtained from reference buccal swabs. Throughout the study, no contamination was observed. The overall first-pass success rate with an "expert-like system" was 72%, which is comparable to another current RDNA platform commercially available. The system's second-pass success rate (involving manual interpretation on first-pass inconclusive results) increased to 90%. Inhibitors (i.e., coffee, smoking tobacco, and chewing tobacco) did not appear to affect typing by the instrument system; however, substrate (i.e., swab type) did impact typing success. Additionally, one desirable feature not available with other Rapid systems is that in the event of a system failed run, a swab can be recovered and subsequently re-analyzed in a new sample cartridge. Therefore, rarely should additional sampling or swab consumption be necessary. The RapidHIT ID system is a robust and reliable tool capable of generating complete STR profiles within the forensic DNA typing laboratory or with proper training in decentralized environments by non-laboratory personnel. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Use of a rapid brain-sampling technique in a physiologic preparation: effects of morphine, ketamine, and halothane on tissue energy intermediates.

    PubMed

    Dedrick, D F; Sherer, Y D; Biebuyck, J F

    1975-06-01

    A new method of rapid sampling of brain tissue, "freeze-blowing," has been used to compare the neurochemistry of the brain during anesthesia with that in the awake state. The method avoids anoxia associated with the sampling process. Physiologic variables, including body temperature, blood-gas tensions and blood pressure, were carefully monitored and controlled in the experimental animals. None of the agents tested (halothane, morphine, and ketamine) reduced the brain tissue high-energy phosphate reserved. All three drugs doubled glucose levels. Morphine lowered both lactate and the lactate/pyruvate ratio. Uniformly, the three anesthetic agents led to twofold increases of brain cyclic 3'-5' adenosine monophosphate concentrations. These changes suggest a possible role for cyclic nucleotides in central neurotransmission.

  11. Cost-effective and Rapid Blood Analysis on a Cell-phone

    PubMed Central

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-01-01

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings. PMID:23392286

  12. Cost-effective and rapid blood analysis on a cell-phone.

    PubMed

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  13. Mass spectrometry-based monitoring of millisecond protein–ligand binding dynamics using an automated microfluidic platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cong, Yongzheng; Katipamula, Shanta; Trader, Cameron D.

    2016-01-01

    Characterizing protein-ligand binding dynamics is crucial for understanding protein function and developing new therapeutic agents. We have developed a novel microfluidic platform that features rapid mixing of protein and ligand solutions, variable incubation times, and on-chip electrospray ionization to perform label-free, solution-based monitoring of protein-ligand binding dynamics. This platform offers many advantages including automated processing, rapid mixing, and low sample consumption.

  14. Miniaturized sample preparation needle: a versatile design for the rapid analysis of smoking-related compounds in hair and air samples.

    PubMed

    Saito, Yoshihiro; Ueta, Ikuo; Ogawa, Mitsuhiro; Hayashida, Makiko; Jinno, Kiyokatsu

    2007-05-09

    Miniaturized needle extraction device has been developed as a versatile sample preparation device designed for the rapid and simple analysis of smoking-related compounds in smokers' hair samples and environmental tobacco smoke. Packed with polymeric particle, the resulting particle-packed needle was employed as a miniaturized sample preparation device for the analysis of typical volatile organic compounds in tobacco smoke. Introducing a bundle of polymer-coated filaments as the extraction medium, the needle was further applied as a novel sample preparation device containing simultaneous derivatization/extraction process of volatile aldehydes. Formaldehyde (FA) and acetaldehyde (AA) in smoker's breath during the smoking were successfully derivatized with two derivatization reagents in the polymer-coated fiber-packed needle device followed by the separation and determination in gas chromatography (GC). Smokers' hair samples were also packed into the needle, allowing the direct extraction of nicotine from the hair sample in a conventional GC injector. Optimizing the main experimental parameters for each technique, successful determination of several smoking-related compounds with these needle extraction methods has been demonstrated.

  15. Atmospheric Solid Analysis Probe Coupled to Ion Mobility Spectrometry-Mass Spectrometry, a Fast and Simple Method for Polyalphaolefin Characterization

    NASA Astrophysics Data System (ADS)

    Mendes Siqueira, Anna Luiza; Beaumesnil, Mathieu; Hubert-Roux, Marie; Loutelier-Bourhis, Corinne; Afonso, Carlos; Bai, Yang; Courtiade, Marion; Racaud, Amandine

    2018-05-01

    Polyalphaolefins (PAOs) are polymers produced from linear alpha olefins through catalytic oligomerization processes. The PAOs are known as synthetic high-performance base stock fluids used to improve the efficiency of many other synthetic products. In this study, we report the direct characterization of PAOs using atmospheric solid analysis probe (ASAP) coupled with ion mobility spectrometry-mass spectrometry (IMS-MS). We studied different PAOs grades exhibiting low- and high-viscosity index. Specific adjustments of the ASAP source parameters permitted the monitoring of ionization processes as three mechanisms could occur for these compounds: hydride abstraction, nitrogen addition, and/or the formation of [M-2H]+• ions. Several series of fragment ions were obtained, which allowed the identification of the alpha olefin used to synthesize the PAO. The use of the ion mobility separation dimension provides information on isomeric species. In addition, the drift time versus m/z plots permitted rapid comparison between PAO samples and to evidence their complexity. These 2D plots appear as fingerprints of PAO samples. To conclude, the resort to ASAP-IMS-MS provides a rapid characterization of the PAO samples in a direct analysis approach, without any sample preparation.

  16. Enteric protozoa of cats and their zoonotic potential-a field study from Austria.

    PubMed

    Hinney, Barbara; Ederer, Christina; Stengl, Carina; Wilding, Katrin; Štrkolcová, Gabriela; Harl, Josef; Flechl, Eva; Fuehrer, Hans-Peter; Joachim, Anja

    2015-05-01

    Domestic cats can be infected with a variety of enteric protozoa. Genotyping of protozoan species, especially Giardia as the most common, can improve assessment of their relevance as zoonotic agents. For an overview on the occurrence of feline enteric protozoa, 298 faecal samples of cats from private households, catteries and animal shelters in Austria were collected. All samples were examined by flotation and using a rapid test for Giardia (FASTest). For the detection of Tritrichomonas blagburni, freshly voided faeces (n = 40) were processed using a commercial culturing system (InPouch TF-Feline). Genotyping was done at the β-giardin gene loci (each sample) and triosephosphate isomerase gene loci (positive samples) for Giardia and at the 18S rRNA gene (positive samples) for Cryptosporidium. Thirty-seven samples (12.4%) were positive for Giardia by flotation and/or using a rapid test. Cryptosporidium was present in 1.7%, Cystoisospora in 4.0%, Sarcocystis in 0.3% and T. blagburni in 2.5% of the samples. Genotyping revealed Giardia cati, the potentially zoonotic Giardia duodenalis and Cryptosporidium felis. Most of the infected cats had no diarrhoea. Cats from shelters were significantly more often infected than owned cats (p = 0.01). When comparing Giardia detection methods, the rapid test had a higher sensitivity than flotation. Polymerase chain reaction (PCR) results were mostly independent from the other two tests.

  17. The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

    PubMed

    Garty, Guy; Chen, Youhua; Turner, Helen C; Zhang, Jian; Lyulko, Oleksandra V; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Lawrence Yao, Y; Brenner, David J

    2011-08-01

    Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. The RABiT analyses fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cut-off dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day.

  18. The RABiT: A Rapid Automated Biodosimetry Tool For Radiological Triage. II. Technological Developments

    PubMed Central

    Garty, Guy; Chen, Youhua; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Brenner, David J.

    2011-01-01

    Purpose Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. Materials and methods The RABiT analyzes fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cutoff dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. Results We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Conclusions Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day. PMID:21557703

  19. Culture-free, highly sensitive, quantitative detection of bacteria from minimally processed samples using fluorescence imaging by smartphone.

    PubMed

    Shrivastava, Sajal; Lee, Won-Il; Lee, Nae-Eung

    2018-06-30

    A critical unmet need in the diagnosis of bacterial infections, which remain a major cause of human morbidity and mortality, is the detection of scarce bacterial pathogens in a variety of samples in a rapid and quantitative manner. Herein, we demonstrate smartphone-based detection of Staphylococcus aureus in a culture-free, rapid, quantitative manner from minimally processed liquid samples using aptamer-functionalized fluorescent magnetic nanoparticles. The tagged S. aureus cells were magnetically captured in a detection cassette, and then fluorescence was imaged using a smartphone camera with a light-emitting diode as the excitation source. Our results showed quantitative detection capability with a minimum detectable concentration as low as 10 cfu/ml by counting individual bacteria cells, efficiently capturing S. aureus cells directly from a peanut milk sample within 10 min. When the selectivity of detection was investigated using samples spiked with other pathogenic bacteria, no significant non-specific detection occurred. Furthermore, strains of S. aureus from various origins showed comparable results, ensuring that the approach can be widely adopted. Therefore, the quantitative fluorescence imaging platform on a smartphone could allow on-site detection of bacteria, providing great potential assistance during major infectious disease outbreaks in remote and resource-limited settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Rapid recovery from the Late Ordovician mass extinction

    NASA Technical Reports Server (NTRS)

    Krug, A. Z.; Patzkowsky, M. E.

    2004-01-01

    Understanding the evolutionary role of mass extinctions requires detailed knowledge of postextinction recoveries. However, most models of recovery hinge on a direct reading of the fossil record, and several recent studies have suggested that the fossil record is especially incomplete for recovery intervals immediately after mass extinctions. Here, we analyze a database of genus occurrences for the paleocontinent of Laurentia to determine the effects of regional processes on recovery and the effects of variations in preservation and sampling intensity on perceived diversity trends and taxonomic rates during the Late Ordovician mass extinction and Early Silurian recovery. After accounting for variation in sampling intensity, we find that marine benthic diversity in Laurentia recovered to preextinction levels within 5 million years, which is nearly 15 million years sooner than suggested by global compilations. The rapid turnover in Laurentia suggests that processes such as immigration may have been particularly important in the recovery of regional ecosystems from environmental perturbations. However, additional regional studies and a global analysis of the Late Ordovician mass extinction that accounts for variations in sampling intensity are necessary to confirm this pattern. Because the record of Phanerozoic mass extinctions and postextinction recoveries may be compromised by variations in preservation and sampling intensity, all should be reevaluated with sampling-standardized analyses if the evolutionary role of mass extinctions is to be fully understood.

  1. Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes

    NASA Astrophysics Data System (ADS)

    Ali, Saima; Hannula, Simo-Pekka

    2017-05-01

    Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO4) solution (Process 1), and ethylene glycol (EG) mixture with HClO4 and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted to nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25-600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m2 g-1 is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes.

  2. Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

    DOE PAGES

    Van Berkel, Gary J.; Kertesz, Vilmos

    2016-11-15

    An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less

  3. Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J.; Kertesz, Vilmos

    An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less

  4. Automatic Aircraft Structural Topology Generation for Multidisciplinary Optimization and Weight Estimation

    NASA Technical Reports Server (NTRS)

    Sensmeier, Mark D.; Samareh, Jamshid A.

    2005-01-01

    An approach is proposed for the application of rapid generation of moderate-fidelity structural finite element models of air vehicle structures to allow more accurate weight estimation earlier in the vehicle design process. This should help to rapidly assess many structural layouts before the start of the preliminary design phase and eliminate weight penalties imposed when actual structure weights exceed those estimated during conceptual design. By defining the structural topology in a fully parametric manner, the structure can be mapped to arbitrary vehicle configurations being considered during conceptual design optimization. A demonstration of this process is shown for two sample aircraft wing designs.

  5. Rapid measurement of meat spoilage using fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Wu, Binlin; Dahlberg, Kevin; Gao, Xin; Smith, Jason; Bailin, Jacob

    2017-02-01

    Food spoilage is mainly caused by microorganisms, such as bacteria. In this study, we measure the autofluorescence in meat samples longitudinally over a week in an attempt to develop a method to rapidly detect meat spoilage using fluorescence spectroscopy. Meat food is a biological tissue, which contains intrinsic fluorophores, such as tryptophan, collagen, nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) etc. As meat spoils, it undergoes various morphological and chemical changes. The concentrations of the native fluorophores present in a sample may change. In particular, the changes in NADH and FAD are associated with microbial metabolism, which is the most important process of the bacteria in food spoilage. Such changes may be revealed by fluorescence spectroscopy and used to indicate the status of meat spoilage. Therefore, such native fluorophores may be unique, reliable and nonsubjective indicators for detection of spoiled meat. The results of the study show that the relative concentrations of all above fluorophores change as the meat samples kept in room temperature ( 19° C) spoil. The changes become more rapidly after about two days. For the meat samples kept in a freezer ( -12° C), the changes are much less or even unnoticeable over a-week-long storage.

  6. Multiplex polymerase chain reaction detection of black-pigmented bacteria in infections of endodontic origin.

    PubMed

    Seol, Jung-Hwan; Cho, Byung-Hoon; Chung, Chong-Pyoung; Bae, Kwang-Shik

    2006-02-01

    The purpose of this study was to detect the presence of Porphyromonas endodontalis, P. gingivalis, Prevotella intermedia, P. nigrescens, and P. tannerae from clinical samples using multiplex polymerase chain reactions (PCR). Two different multiplex PCR protocols were used (one for the two Porphyromonas species and the other for the three Prevotella species), each one using a primer pair specific for each target species. The results were compared to those of the conventional culture procedures. Microbial samples were taken aseptically from 40 infected root canals and abscesses from patients. Samples were cultured in an anaerobic condition for conventional identification using a Rapid ID 32 A kit. Multiplex PCR was processed using the DNA extracted from each sample. At least one of the five species of black-pigmented bacteria (BPB) were detected in 65% (26 of 40) of the samples using multiplex PCR, and in 15% (6 of 40) using the conventional culture procedures. Multiplex PCR was more rapid, sensitive, specific, and effective in detecting BPB than the conventional culture procedures.

  7. Innovative food processing technology using ohmic heating and aseptic packaging for meat.

    PubMed

    Ito, Ruri; Fukuoka, Mika; Hamada-Sato, Naoko

    2014-02-01

    Since the Tohoku earthquake, there is much interest in processed foods, which can be stored for long periods at room temperature. Retort heating is one of the main technologies employed for producing it. We developed the innovative food processing technology, which supersede retort, using ohmic heating and aseptic packaging. Electrical heating involves the application of alternating voltage to food. Compared with retort heating, which uses a heat transfer medium, ohmic heating allows for high heating efficiency and rapid heating. In this paper we ohmically heated chicken breast samples and conducted various tests on the heated samples. The measurement results of water content, IMP, and glutamic acid suggest that the quality of the ohmically heated samples was similar or superior to that of the retort-heated samples. Furthermore, based on the monitoring of these samples, it was observed that sample quality did not deteriorate during storage. © 2013. Published by Elsevier Ltd on behalf of The American Meat Science Association. All rights reserved.

  8. Rapid quality assessment of Radix Aconiti Preparata using direct analysis in real time mass spectrometry.

    PubMed

    Zhu, Hongbin; Wang, Chunyan; Qi, Yao; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2012-11-08

    This study presents a novel and rapid method to identify chemical markers for the quality control of Radix Aconiti Preparata, a world widely used traditional herbal medicine. In the method, the samples with a fast extraction procedure were analyzed using direct analysis in real time mass spectrometry (DART MS) combined with multivariate data analysis. At present, the quality assessment approach of Radix Aconiti Preparata was based on the two processing methods recorded in Chinese Pharmacopoeia for the purpose of reducing the toxicity of Radix Aconiti and ensuring its clinical therapeutic efficacy. In order to ensure the safety and effectivity in clinical use, the processing degree of Radix Aconiti should be well controlled and assessed. In the paper, hierarchical cluster analysis and principal component analysis were performed to evaluate the DART MS data of Radix Aconiti Preparata samples in different processing times. The results showed that the well processed Radix Aconiti Preparata, unqualified processed and the raw Radix Aconiti could be clustered reasonably corresponding to their constituents. The loading plot shows that the main chemical markers having the most influence on the discrimination amongst the qualified and unqualified samples were mainly some monoester diterpenoid aconitines and diester diterpenoid aconitines, i.e. benzoylmesaconine, hypaconitine, mesaconitine, neoline, benzoylhypaconine, benzoylaconine, fuziline, aconitine and 10-OH-mesaconitine. The established DART MS approach in combination with multivariate data analysis provides a very flexible and reliable method for quality assessment of toxic herbal medicine. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; processing, taxonomy, and quality control of benthic macroinvertebrate samples

    USGS Publications Warehouse

    Moulton, Stephen R.; Carter, James L.; Grotheer, Scott A.; Cuffney, Thomas F.; Short, Terry M.

    2000-01-01

    Qualitative and quantitative methods to process benthic macroinvertebrate (BMI) samples have been developed and tested by the U.S. Geological Survey?s National Water Quality Laboratory Biological Group. The qualitative processing method is based on visually sorting a sample for up to 2 hours. Sorting focuses on attaining organisms that are likely to result in taxonomic identifications to lower taxonomic levels (for example, Genus or Species). Immature and damaged organisms are also sorted when they are likely to result in unique determinations. The sorted sample remnant is scanned briefly by a second person to determine if obvious taxa were missed. The quantitative processing method is based on a fixed-count approach that targets some minimum count, such as 100 or 300 organisms. Organisms are sorted from randomly selected 5.1- by 5.1-centimeter parts of a gridded subsampling frame. The sorted remnant from each sample is resorted by a second individual for at least 10 percent of the original sort time. A large-rare organism search is performed on the unsorted remnant to sort BMI taxa that were not likely represented in the sorted grids. After either qualitatively or quantitatively sorting the sample, BMIs are identified by using one of three different types of taxonomic assessment. The Standard Taxonomic Assessment is comparable to the U.S. Environmental Protection Agency Rapid Bioassessment Protocol III and typically provides Genus- or Species-level taxonomic resolution. The Rapid Taxonomic Assessment is comparable to the U.S. Environmental Protection Agency Rapid Bioassessment Protocol II and provides Familylevel and higher taxonomic resolution. The Custom Taxonomic Assessment provides Species-level resolution whenever possible for groups identified to higher taxonomic levels by using the Standard Taxonomic Assessment. The consistent use of standardized designations and notes facilitates the interpretation of BMI data within and among water-quality studies. Taxonomic identifications are quality assured by verifying all referenced taxa and randomly reviewing 10 percent of the taxonomic identifications performed weekly by Biological Group taxonomists. Taxonomic errors discovered during this review are corrected. BMI data are reviewed for accuracy and completeness prior to release. BMI data are released phylogenetically in spreadsheet format and unprocessed abundances are corrected for laboratory and field subsampling when necessary.

  10. The Resin-Embedded Cornea Prepared Via Rapid Processing Protocol : A Good Histomorphometric Target for Clinical Investigation in Ophthalmology and Optometry

    PubMed Central

    Cheah, Pike See; Mohidin, Norhani; Mohd Ali, Bariah; Maung, Myint; Latif, Azian Abdul

    2008-01-01

    This study illustrates and quantifies the changes on corneal tissue between the paraffin-embedded and resin-embedded blocks and thus, selects a better target in investigational ophthalmology and optometry via light microscopy. Corneas of two cynomolgus monkeys (Macaca fascicularis) were used in this study. The formalin-fixed cornea was prepared in paraffin block via the conventional tissue processing protocol (4-day protocol) and stained with haematoxylin and eosin. The glutaraldehyde-fixed cornea was prepared in resin block via the rapid and modified tissue processing procedure (1.2-day protocol) and stained with toluidine blue. The paraffin-embedded sample exhibits various undesired tissue damage and artifact such as thinner epithelium (due to the substantial volumic extraction from the tissue), thicker stroma layer (due to the separation of lamellae and the presence of voids) and the distorted endothelium. In contrast, the resin-embedded corneal tissue has demonstrated satisfactory corneal ultrastructural preservation. The rapid and modified tissue processing method for preparing the resin-embedded is particularly beneficial to accelerate the microscopic evaluation in ophthalmology and optometry. PMID:22570589

  11. Inferring the demographic history from DNA sequences: An importance sampling approach based on non-homogeneous processes.

    PubMed

    Ait Kaci Azzou, S; Larribe, F; Froda, S

    2016-10-01

    In Ait Kaci Azzou et al. (2015) we introduced an Importance Sampling (IS) approach for estimating the demographic history of a sample of DNA sequences, the skywis plot. More precisely, we proposed a new nonparametric estimate of a population size that changes over time. We showed on simulated data that the skywis plot can work well in typical situations where the effective population size does not undergo very steep changes. In this paper, we introduce an iterative procedure which extends the previous method and gives good estimates under such rapid variations. In the iterative calibrated skywis plot we approximate the effective population size by a piecewise constant function, whose values are re-estimated at each step. These piecewise constant functions are used to generate the waiting times of non homogeneous Poisson processes related to a coalescent process with mutation under a variable population size model. Moreover, the present IS procedure is based on a modified version of the Stephens and Donnelly (2000) proposal distribution. Finally, we apply the iterative calibrated skywis plot method to a simulated data set from a rapidly expanding exponential model, and we show that the method based on this new IS strategy correctly reconstructs the demographic history. Copyright © 2016. Published by Elsevier Inc.

  12. How to: identify non-tuberculous Mycobacterium species using MALDI-TOF mass spectrometry.

    PubMed

    Alcaide, F; Amlerová, J; Bou, G; Ceyssens, P J; Coll, P; Corcoran, D; Fangous, M-S; González-Álvarez, I; Gorton, R; Greub, G; Hery-Arnaud, G; Hrábak, J; Ingebretsen, A; Lucey, B; Marekoviċ, I; Mediavilla-Gradolph, C; Monté, M R; O'Connor, J; O'Mahony, J; Opota, O; O'Reilly, B; Orth-Höller, D; Oviaño, M; Palacios, J J; Palop, B; Pranada, A B; Quiroga, L; Rodríguez-Temporal, D; Ruiz-Serrano, M J; Tudó, G; Van den Bossche, A; van Ingen, J; Rodriguez-Sanchez, B

    2018-06-01

    The implementation of MALDI-TOF MS for microorganism identification has changed the routine of the microbiology laboratories as we knew it. Most microorganisms can now be reliably identified within minutes using this inexpensive, user-friendly methodology. However, its application in the identification of mycobacteria isolates has been hampered by the structure of their cell wall. Improvements in the sample processing method and in the available database have proved key factors for the rapid and reliable identification of non-tuberculous mycobacteria isolates using MALDI-TOF MS. The main objective is to provide information about the proceedings for the identification of non-tuberculous isolates using MALDI-TOF MS and to review different sample processing methods, available databases, and the interpretation of the results. Results from relevant studies on the use of the available MALDI-TOF MS instruments, the implementation of innovative sample processing methods, or the implementation of improved databases are discussed. Insight about the methodology required for reliable identification of non-tuberculous mycobacteria and its implementation in the microbiology laboratory routine is provided. Microbiology laboratories where MALDI-TOF MS is available can benefit from its capacity to identify most clinically interesting non-tuberculous mycobacteria in a rapid, reliable, and inexpensive manner. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  13. [Study on rapid analysis method of pesticide contamination in processed foods by GC-MS and GC-FPD].

    PubMed

    Kobayashi, Maki; Otsuka, Kenji; Tamura, Yasuhiro; Tomizawa, Sanae; Kamijo, Kyoko; Iwakoshi, Keiko; Sato, Chizuko; Nagayama, Toshihiro; Takano, Ichiro

    2011-01-01

    A simple and rapid method using GC-MS and GC-FPD for the determination of pesticide contamination in processed food has been developed. Pesticides were extracted from a sample with ethyl acetate in the presence of anhydrous sodium sulfate, then cleaned up with a combination of mini-columns, such as macroporous diatomaceous earth, C18, GCB (graphite carbon black) and PSA. Recovery tests of 57 pesticides (known to be toxic or harmful) from ten kinds of processed foods (butter, cheese, corned beef, dried shrimp, frozen Chinese dumplings, grilled eels, instant noodles, kimchi, retort-packed curry and wine) were performed, and the recovery rates were mostly between 70% and 120%. This method can be used to judge whether or not processed foods are contaminated with pesticides at potentially harmful levels.

  14. Evaluating mixed samples as a source of error in non-invasive genetic studies using microsatellites

    USGS Publications Warehouse

    Roon, David A.; Thomas, M.E.; Kendall, K.C.; Waits, L.P.

    2005-01-01

    The use of noninvasive genetic sampling (NGS) for surveying wild populations is increasing rapidly. Currently, only a limited number of studies have evaluated potential biases associated with NGS. This paper evaluates the potential errors associated with analysing mixed samples drawn from multiple animals. Most NGS studies assume that mixed samples will be identified and removed during the genotyping process. We evaluated this assumption by creating 128 mixed samples of extracted DNA from brown bear (Ursus arctos) hair samples. These mixed samples were genotyped and screened for errors at six microsatellite loci according to protocols consistent with those used in other NGS studies. Five mixed samples produced acceptable genotypes after the first screening. However, all mixed samples produced multiple alleles at one or more loci, amplified as only one of the source samples, or yielded inconsistent electropherograms by the final stage of the error-checking process. These processes could potentially reduce the number of individuals observed in NGS studies, but errors should be conservative within demographic estimates. Researchers should be aware of the potential for mixed samples and carefully design gel analysis criteria and error checking protocols to detect mixed samples.

  15. A procedure for estimating Bacillus cereus spores in soil and stream-sediment samples - A potential exploration technique

    USGS Publications Warehouse

    Watterson, J.R.

    1985-01-01

    The presence of bacterial spores of the Bacillus cereus group in soils and stream sediments appears to be a sensitive indicator of several types of concealed mineral deposits, including vein-type gold deposits. The B. cereus assay is rapid, inexpensive, and inherently reproducible. The test, currently under investigation for its potential in mineral exploration, is recommended for use on a research basis. Among the aerobic spore-forming bacilli, only B. cereus and closely related strains produce an opaque zone in egg-yolk emulsion agar. This characteristic, also known as the Nagler of lecitho-vitellin reaction, has long been used to rapidly indentify and estimate presumptive B. cereus. The test is here adapted to permit rapid estimation of B. cereus spores in soil and stream-sediment samples. Relative standard deviation was 10.3% on counts obtained from two 40-replicate pour-plate determinations. As many as 40 samples per day can be processed. Enough procedural detail is included to permit investigation of the test in conventional geochemical laboratories using standard microbiological safety precautions. ?? 1985.

  16. Rapid shape detection signals in area V4

    PubMed Central

    Weiner, Katherine F.; Ghose, Geoffrey M.

    2014-01-01

    Vision in foveate animals is an active process that requires rapid and constant decision-making. For example, when a new object appears in the visual field, we can quickly decide to inspect it by directing our eyes to the object's location. We studied the contribution of primate area V4 to these types of rapid foveation decisions. Animals performed a reaction time task that required them to report when any shape appeared within a peripherally-located noisy stimulus by making a saccade to the stimulus location. We found that about half of the randomly sampled V4 neurons not only rapidly and precisely represented the appearance of this shape, but they were also predictive of the animal's saccades. A neuron's ability to predict the animal's saccades was not related to the specificity with which the cell represented a single type of shape but rather to its ability to signal whether any shape was present. This relationship between sensory sensitivity and behavioral predictiveness was not due to global effects such as alertness, as it was equally likely to be observed for cells with increases and decreases in firing rate. Careful analysis of the timescales of reliability in these neurons implies that they reflect both feedforward and feedback shape detecting processes. In approximately 7% of our recorded sample, individual neurons were able to predict both the delay and precision of the animal's shape detection performance. This suggests that a subset of V4 neurons may have been directly and causally contributing to task performance and that area V4 likely plays a critical role in guiding rapid, form-based foveation decisions. PMID:25278828

  17. Low-cycle fatigue of Fe-20%Cr alloy processed by equal- channel angular pressing

    NASA Astrophysics Data System (ADS)

    Kaneko, Yoshihisa; Tomita, Ryuji; Vinogradov, Alexei

    2014-08-01

    Low-cycle fatigue properties were investigated on Fe-20%Cr ferritic stainless steel processed by equal channel angular pressing (ECAP). The Fe-20%Cr alloy bullets were processed for one to four passes via Route-Bc. The ECAPed samples were cyclically deformed at the constant plastic strain amplitude ɛpl of 5x10-4 at room temperature in air. After the 1-pass ECAP, low-angle grain boundaries were dominantly formed. During the low-cycle fatigue test, the 1-pass sample revealed the rapid softening which continued until fatigue fracture. Fatigue life of the 1-pass sample was shorter than that of a coarse-grained sample. After the 4-pass ECAP, the average grain size reduced down to about 1.5 μm. At initial stage of the low-cycle fatigue tests, the stress amplitude increased with increasing ECAP passes. At the samples processed for more than 2 passes, the cyclic softening was relatively moderate. It was found that fatigue life of the ECAPed Fe-20%Cr alloy excepting the 1-pass sample was improved as compared to the coarse-grained sample, even under the strain controlled fatigue condition.

  18. Rapid identification of Bacillus anthracis spores in suspicious powder samples by using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS).

    PubMed

    Dybwad, Marius; van der Laaken, Anton L; Blatny, Janet Martha; Paauw, Armand

    2013-09-01

    Rapid and reliable identification of Bacillus anthracis spores in suspicious powders is important to mitigate the safety risks and economic burdens associated with such incidents. The aim of this study was to develop and validate a rapid and reliable laboratory-based matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis method for identifying B. anthracis spores in suspicious powder samples. A reference library containing 22 different Bacillus sp. strains or hoax materials was constructed and coupled with a novel classification algorithm and standardized processing protocol for various powder samples. The method's limit of B. anthracis detection was determined to be 2.5 × 10(6) spores, equivalent to a 55-μg sample size of the crudest B. anthracis-containing powder discovered during the 2001 Amerithrax incidents. The end-to-end analysis method was able to successfully discriminate among samples containing B. anthracis spores, closely related Bacillus sp. spores, and commonly encountered hoax materials. No false-positive or -negative classifications of B. anthracis spores were observed, even when the analysis method was challenged with a wide range of other bacterial agents. The robustness of the method was demonstrated by analyzing samples (i) at an external facility using a different MALDI-TOF MS instrument, (ii) using an untrained operator, and (iii) using mixtures of Bacillus sp. spores and hoax materials. Taken together, the observed performance of the analysis method developed demonstrates its potential applicability as a rapid, specific, sensitive, robust, and cost-effective laboratory-based analysis tool for resolving incidents involving suspicious powders in less than 30 min.

  19. A simple, rapid, cost-effective and sensitive method for detection of Salmonella in environmental and pecan samples.

    PubMed

    Dobhal, S; Zhang, G; Rohla, C; Smith, M W; Ma, L M

    2014-10-01

    PCR is widely used in the routine detection of foodborne human pathogens; however, challenges remain in overcoming PCR inhibitors present in some sample matrices. The objective of this study was to develop a simple, sensitive, cost-effective and rapid method for processing large numbers of environmental and pecan samples for Salmonella detection. This study was also aimed at validation of a new protocol for the detection of Salmonella from in-shell pecans. Different DNA template preparation methods, including direct boiling, prespin, multiple washing and commercial DNA extraction kits, were evaluated with pure cultures of Salmonella Typhimurium and with enriched soil, cattle feces and in-shell pecan each spiked individually with Salmonella Typhimurium. PCR detection of Salmonella was conducted using invA and 16S rRNA gene (internal amplification control) specific primers. The effect of amplification facilitators, including bovine serum albumin (BSA), polyvinylpyrrolidone (PVP), polyethylene glycol (PEG) and gelatin on PCR sensitivity, was also evaluated. Conducting a prespin of sample matrices in combination with the addition of 0·4% (w/v) BSA and 1% (w/v) PVP in PCR mix was the simplest, most rapid, cost-effective and sensitive method for PCR detection of Salmonella, with up to 40 CFU Salmonella per reaction detectable in the presence of over 10(9 ) CFU ml(-1) of background micro-organisms from enriched feces soil or pecan samples. The developed method is rapid, cost-effective and sensitive for detection of Salmonella from different matrices. This study provides a method with broad applicability for PCR detection of Salmonella in complex sample matrices. This method has a potential for its application in different research arenas and diagnostic laboratories. © 2014 The Society for Applied Microbiology.

  20. Rapid Identification of Bacillus anthracis Spores in Suspicious Powder Samples by Using Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry (MALDI-TOF MS)

    PubMed Central

    van der Laaken, Anton L.; Blatny, Janet Martha; Paauw, Armand

    2013-01-01

    Rapid and reliable identification of Bacillus anthracis spores in suspicious powders is important to mitigate the safety risks and economic burdens associated with such incidents. The aim of this study was to develop and validate a rapid and reliable laboratory-based matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) analysis method for identifying B. anthracis spores in suspicious powder samples. A reference library containing 22 different Bacillus sp. strains or hoax materials was constructed and coupled with a novel classification algorithm and standardized processing protocol for various powder samples. The method's limit of B. anthracis detection was determined to be 2.5 × 106 spores, equivalent to a 55-μg sample size of the crudest B. anthracis-containing powder discovered during the 2001 Amerithrax incidents. The end-to-end analysis method was able to successfully discriminate among samples containing B. anthracis spores, closely related Bacillus sp. spores, and commonly encountered hoax materials. No false-positive or -negative classifications of B. anthracis spores were observed, even when the analysis method was challenged with a wide range of other bacterial agents. The robustness of the method was demonstrated by analyzing samples (i) at an external facility using a different MALDI-TOF MS instrument, (ii) using an untrained operator, and (iii) using mixtures of Bacillus sp. spores and hoax materials. Taken together, the observed performance of the analysis method developed demonstrates its potential applicability as a rapid, specific, sensitive, robust, and cost-effective laboratory-based analysis tool for resolving incidents involving suspicious powders in less than 30 min. PMID:23811517

  1. Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry.

    PubMed

    Van Berkel, Gary J; Kertesz, Vilmos

    2017-02-15

    An "Open Access"-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendor-provided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. Using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. This work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

  2. FNAS modify matric and transparent experiments

    NASA Technical Reports Server (NTRS)

    Smith, Guy A.; Kosten, Sue E.; Workman, Gary L.

    1992-01-01

    Monotectic alloy materials are created by rapid melt/rapid solidification processing on the NASA KC-135. Separation of the uniform liquid into two liquids may occur by either of two processes; spinodal decomposition or nucleation followed by growth. In the first case, the liquid is unstable to composition waves, which form and grow, giving liquids of two different compositions. In the latter process discrete particles of the second liquid phase form via thermal fluctuations and then grow by diffusion. The two processes are very different, with the determining process being dictated by temperature, composition, and thermodynamic characteristics of the alloy. The first two quantities are process variables, while the third is determined by electronic interactions between the atoms in the alloy. In either case the initial alloy decomposition is followed by coarsening, resulting in growth of the particle size at nearly constant volume fraction. In particular, reduced gravity experiments on monotectic solutions have shown a number of interesting results in the KC-135. Monotectic solutions exhibit a miscibility gap in the liquid state, and consequently, gravity driven forces can dominate the solidification parameters at 1 g. In reduced gravity however, the distribution of the phases is different, resulting in new and interesting microstructures. The Rapid Melt/Rapid Quench Furnace allows one to melt a sample and resolidify it in one parabola of the KC-135's flight path, thus eliminating any accumulative influence of multiple parabolas to affect the microstructure of the material.

  3. Sample processing approach for detection of ricin in surface samples.

    PubMed

    Kane, Staci; Shah, Sanjiv; Erler, Anne Marie; Alfaro, Teneile

    2017-12-01

    With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. The procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required. Published by Elsevier B.V.

  4. An efficient, reliable and inexpensive device for the rapid homogenization of multiple tissue samples by centrifugation.

    PubMed

    Ilyin, S E; Plata-Salamán, C R

    2000-02-15

    Homogenization of tissue samples is a common first step in the majority of current protocols for RNA, DNA, and protein isolation. This report describes a simple device for centrifugation-mediated homogenization of tissue samples. The method presented is applicable to RNA, DNA, and protein isolation, and we show examples where high quality total cell RNA, DNA, and protein were obtained from brain and other tissue samples. The advantages of the approach presented include: (1) a significant reduction in time investment relative to hand-driven or individual motorized-driven pestle homogenization; (2) easy construction of the device from inexpensive parts available in any laboratory; (3) high replicability in the processing; and (4) the capacity for the parallel processing of multiple tissue samples, thus allowing higher efficiency, reliability, and standardization.

  5. Rapid Active Sampling Package

    NASA Technical Reports Server (NTRS)

    Peters, Gregory

    2010-01-01

    A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni/Cad rechargeable battery. Power usage was less than 1 Wh/ cm3 even when sampling strong basalts, so many samples could be taken on a single battery charge.

  6. Estimation of Soil Nitrate (NO3) Level Using Laser-Induced Breakdown Spectroscopy (LIBS)

    NASA Astrophysics Data System (ADS)

    Angkat, A. R.; Seminar, K. B.; Rahmat, M.; Sutandi, A.

    2018-05-01

    Laser-Induced Breakdown Spectroscopy (LIBS) is a method for measuring level of nitrogen (N) in the soil in the form of N-nitrate (NO3) rapidly without going through the process of sieving and drying. The sample soil in the form of pellets subjected to laser pulses using a wavelength of 532 nm, pulse duration 5.5 ns, repetition rate of 10 Hz, and Q-switch delay of 150 μs. Emissions are captured by the spectrometer with the wavelength range of 190-1130 nm. Spectrum characterization was processed through the second derivative in order to obtain a wavelength identity that could be rapidly used to estimate the nitrate content of the soil with a determination coefficient of (R2) 0.9254 and a coefficient of variation (CV) of 8.41%. The results of this study are very potential to be applied for rapid measurement of soil nitrate.

  7. Which neuropsychological functions predict various processing speed components in children with and without attention-deficit/hyperactivity disorder?

    PubMed

    Vadnais, Sarah A; Kibby, Michelle Y; Jagger-Rickels, Audreyana C

    2018-01-01

    We identified statistical predictors of four processing speed (PS) components in a sample of 151 children with and without attention-deficit/hyperactivity disorder (ADHD). Performance on perceptual speed was predicted by visual attention/short-term memory, whereas incidental learning/psychomotor speed was predicted by verbal working memory. Rapid naming was predictive of each PS component assessed, and inhibition predicted all but one task, suggesting a shared need to identify/retrieve stimuli rapidly and inhibit incorrect responding across PS components. Hence, we found both shared and unique predictors of perceptual, cognitive, and output speed, suggesting more specific terminology should be used in future research on PS in ADHD.

  8. Centrifuge-less dispersive liquid-liquid microextraction base on the solidification of switchable solvent for rapid on-site extraction of four pyrethroid insecticides in water samples.

    PubMed

    Hu, Lu; Wang, Huazi; Qian, Heng; Liu, Chaoran; Lu, Runhua; Zhang, Sanbing; Zhou, Wenfeng; Gao, Haixiang; Xu, Donghui

    2016-11-11

    An on-site dispersive liquid liquid microextraction base on the solidification of switchable solvent has been developed as a simple, rapid and eco-friendly sample extraction method for the fast determination of pyrethroid insecticides in aqueous samples using high-performance liquid chromatography with ultraviolet detection. In this extraction method, medium-chain saturated fatty acids (n≥10), which can rapidly solidify at low temperatures (<20°C), were investigated as switchable hydrophilic solvents. The fatty acids were converted into the hydrophilic form by adding sodium hydroxide. Microdroplets of the fatty acids were generated when injected into an acidic sample that had been pretreated by the addition of sulfuric acid. The formed cloudy solution was cooled to a low temperature to turn the fatty acids into a solid, which was then separated by filtration, thus avoiding the time-consuming step of centrifugation. The microextraction process was performed in a 10mL syringe and the pretreatment process could thus be finished in 5min. No external energy resources were required in this method, which makes it a potential method for on-site extraction. The optimal experimental parameters were as follows: 350μL of decanoic acid (1mol/L) was used as the extraction solvent, 150μL of sulfuric acid (2mol/L) was used to decrease the pH of the samples, no salt was added, and the temperature of the samples was in the range of 20-40°C. Finally, the sample was cooled in an ice bath for three minutes. Under these optimal conditions, good responses for four pyrethroid insecticides were obtained in the concentration ranges of 1-500μg/L, with coefficients of determination greater than 0.9993. The recoveries of the four pyrethroid insecticides ranged from 84.7 to 95.3%, with relative standard deviations ranging from 1.6 to 4.6%. The limits of detection based on a signal-to-noise ratio of 3 were in the range of 0.24-0.68μg/L, and the enrichment factors were in the range of 121-136. The results demonstrate that this method was successfully applied to determine pyrethroid insecticides in real water samples. No centrifugation or any special apparatus are required, make this a promising method for rapid field-sampling procedures. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Rapid BRAF mutation tests in patients with advanced melanoma: comparison of immunohistochemistry, Droplet Digital PCR, and the Idylla Mutation Platform

    PubMed Central

    Bisschop, Cornelis; ter Elst, Arja; Bosman, Lisette J.; Platteel, Inge; Jalving, Mathilde; van den Berg, Anke; Diepstra, Arjan; van Hemel, Bettien; Diercks, Gilles F.H.; Hospers, Geke A.P.

    2018-01-01

    BRAF mutational testing has become a common practice in the diagnostic process of patients with advanced melanoma. Although time-consuming, DNA sequencing techniques are the current gold standard for mutational testing. However, in certain clinical situations, a rapid test result is required. In this study, the performance of three rapid BRAF mutation tests was compared. Thirty-nine formalin-fixed paraffin-embedded melanoma tissue samples collected between 2007 and 2014 at a single center were included. These samples were analyzed by immunohistochemistry using the anti-BRAF-V600E (VE1) mouse monocolonal antibody (BRAF-VE1 IHC), a V600E-specific Droplet Digital PCR Test, and the Idylla BRAF- Mutation Test (Idylla). Results were compared with the results of conventional BRAF mutation testing, performed using high-resolution melting analysis followed by Sanger sequencing. Next-generation sequencing was performed on samples with discordant results. The Idylla test and Droplet Digital PCR Test correctly identified all mutated and wild-type samples. BRAF-VE1 IHC showed one discordant result. The Idylla test could identify BRAF-V600 mutations other than BRAF-V600E and was the fastest and least laborious test. The Idylla Mutation Test is the most suitable test for rapid BRAF testing in clinical situations on the basis of the broad coverage of treatment-responsive mutations and the fast procedure without the need to perform a DNA isolation step. PMID:29232304

  10. Surface Flashover of Semiconductors: A Fundamental Study

    DTIC Science & Technology

    1993-06-16

    surface electric fields for a number of samples with aluminum and gold contacts. Effects of processing varia- tions such as anneal method (rapid thermal...more uniform pre- breakdown surface fields. 3. Various contact materials and processing methods were used to determine effects on flashover...diffusion depths determined by this method were generally consistent with the estimated depths. 2-4 In order to characterize better the diffused layers

  11. A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing

    NASA Technical Reports Server (NTRS)

    Arevalo, Ricardo, Jr.; Coyle, Barry; Paulios, Demetrios; Stysley, Paul; Feng, Steve; Getty, Stephanie; Binkerhoff, William

    2015-01-01

    Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).

  12. [The taking and transport of biological samples].

    PubMed

    Kerwat, Klaus; Kerwat, Martina; Eberhart, Leopold; Wulf, Hinnerk

    2011-05-01

    The results of microbiological tests are the foundation for a targetted therapy and the basis for monitoring infections. The quality of each and every laboratory finding depends not only on an error-free analytical process. The pre-analysis handling procedures are of particular importance. They encompass all factors and influences prior to the actual analysis. These include the correct timepoint for sample taking, the packaging and the rapid transport of the material to be investigated. Errors in the pre-analytical processing are the most frequent reasons for inappropriate findings. © Georg Thieme Verlag Stuttgart · New York.

  13. Rapid Processing of Turner Designs Model 10-Au-005 Internally Logged Fluorescence Data

    EPA Science Inventory

    Continuous recording of dye fluorescence using field fluorometers at selected sampling sites facilitates acquisition of real-time dye tracing data. The Turner Designs Model 10-AU-005 field fluorometer allows for frequent fluorescence readings, data logging, and easy downloading t...

  14. BEAP profiles as rapid test system for status analysis and early detection of process incidents in biogas plants.

    PubMed

    Refai, Sarah; Berger, Stefanie; Wassmann, Kati; Hecht, Melanie; Dickhaus, Thomas; Deppenmeier, Uwe

    2017-03-01

    A method was developed to quantify the performance of microorganisms involved in different digestion levels in biogas plants. The test system was based on the addition of butyrate (BCON), ethanol (ECON), acetate (ACON) or propionate (PCON) to biogas sludge samples and the subsequent analysis of CH 4 formation in comparison to control samples. The combination of the four values was referred to as BEAP profile. Determination of BEAP profiles enabled rapid testing of a biogas plant's metabolic state within 24 h and an accurate mapping of all degradation levels in a lab-scale experimental setup. Furthermore, it was possible to distinguish between specific BEAP profiles for standard biogas plants and for biogas reactors with process incidents (beginning of NH 4 + -N inhibition, start of acidification, insufficient hydrolysis and potential mycotoxin effects). Finally, BEAP profiles also functioned as a warning system for the early prediction of critical NH 4 + -N concentrations leading to a drop of CH 4 formation.

  15. Active Sampling State Dynamically Enhances Olfactory Bulb Odor Representation.

    PubMed

    Jordan, Rebecca; Fukunaga, Izumi; Kollo, Mihaly; Schaefer, Andreas T

    2018-06-27

    The olfactory bulb (OB) is the first site of synaptic odor information processing, yet a wealth of contextual and learned information has been described in its activity. To investigate the mechanistic basis of contextual modulation, we use whole-cell recordings to measure odor responses across rapid learning episodes in identified mitral/tufted cells (MTCs). Across these learning episodes, diverse response changes occur already during the first sniff cycle. Motivated mice develop active sniffing strategies across learning that robustly correspond to the odor response changes, resulting in enhanced odor representation. Evoking fast sniffing in different behavioral states demonstrates that response changes during active sampling exceed those predicted from feedforward input alone. Finally, response changes are highly correlated in tufted cells, but not mitral cells, indicating there are cell-type-specific effects on odor representation during active sampling. Altogether, we show that active sampling is strongly associated with enhanced OB responsiveness on rapid timescales. Copyright © 2018 The Francis Crick Institute. Published by Elsevier Inc. All rights reserved.

  16. Technologies for imaging neural activity in large volumes

    PubMed Central

    Ji, Na; Freeman, Jeremy; Smith, Spencer L.

    2017-01-01

    Neural circuitry has evolved to form distributed networks that act dynamically across large volumes. Collecting data from individual planes, conventional microscopy cannot sample circuitry across large volumes at the temporal resolution relevant to neural circuit function and behaviors. Here, we review emerging technologies for rapid volume imaging of neural circuitry. We focus on two critical challenges: the inertia of optical systems, which limits image speed, and aberrations, which restrict the image volume. Optical sampling time must be long enough to ensure high-fidelity measurements, but optimized sampling strategies and point spread function engineering can facilitate rapid volume imaging of neural activity within this constraint. We also discuss new computational strategies for the processing and analysis of volume imaging data of increasing size and complexity. Together, optical and computational advances are providing a broader view of neural circuit dynamics, and help elucidate how brain regions work in concert to support behavior. PMID:27571194

  17. Validation of an antibody-based biosensor for rapid quantification of 2,4,6-trinitrotoluene (TNT) contamination in ground water and river water.

    PubMed

    Bromage, Erin S; Vadas, George G; Harvey, Ellen; Unger, Michael A; Kaattari, Stephen L

    2007-10-15

    Nitroaromatics are common pollutants of soil and groundwater at military installations because of their manufacture, storage, and use at these sites. Long-term monitoring of these pollutants comprise a significant percentage of restoration costs. Further, remediation activities often have to be delayed, while the samples are processed via traditional chemical assessment protocols. Here we describe a rapid (<5 min), cost-effective, accurate method using a KinExA Inline Biosensor for monitoring of 2,4,6-trinitrotoluene (TNT) in field water samples. The biosensor, which is based on KinExA technology, accurately estimated the concentration of TNT in double-blind comparisons with similar accuracy to traditional high-performance liquid chromatography(HPLC). In the assessment of field samples, the biosensor accurately predicted the concentration of TNT over the range of 1-30,000 microg/L when compared to either HPLC or quantitative gas chromatography-mass spectrometry (GC-MS). Various pre-assessment techniques were explored to examine whether field samples could be assessed untreated, without the removal of particulates or the use of solvents. In most cases, the KinExA Inline Biosensor gave a uniform assessment of TNT concentration independent of pretreatment method. This indicates that this sensor possesses significant promise for rapid, on-site assessment of TNT pollution in environmental water samples.

  18. NIPTmer: rapid k-mer-based software package for detection of fetal aneuploidies.

    PubMed

    Sauk, Martin; Žilina, Olga; Kurg, Ants; Ustav, Eva-Liina; Peters, Maire; Paluoja, Priit; Roost, Anne Mari; Teder, Hindrek; Palta, Priit; Brison, Nathalie; Vermeesch, Joris R; Krjutškov, Kaarel; Salumets, Andres; Kaplinski, Lauris

    2018-04-04

    Non-invasive prenatal testing (NIPT) is a recent and rapidly evolving method for detecting genetic lesions, such as aneuploidies, of a fetus. However, there is a need for faster and cheaper laboratory and analysis methods to make NIPT more widely accessible. We have developed a novel software package for detection of fetal aneuploidies from next-generation low-coverage whole genome sequencing data. Our tool - NIPTmer - is based on counting pre-defined per-chromosome sets of unique k-mers from raw sequencing data, and applying linear regression model on the counts. Additionally, the filtering process used for k-mer list creation allows one to take into account the genetic variance in a specific sample, thus reducing the source of uncertainty. The processing time of one sample is less than 10 CPU-minutes on a high-end workstation. NIPTmer was validated on a cohort of 583 NIPT samples and it correctly predicted 37 non-mosaic fetal aneuploidies. NIPTmer has the potential to reduce significantly the time and complexity of NIPT post-sequencing analysis compared to mapping-based methods. For non-commercial users the software package is freely available at http://bioinfo.ut.ee/NIPTMer/ .

  19. Ultra-rapid auxin metabolite profiling for high-throughput mutant screening in Arabidopsis.

    PubMed

    Pencík, Aleš; Casanova-Sáez, Rubén; Pilarová, Veronika; Žukauskaite, Asta; Pinto, Rui; Micol, José Luis; Ljung, Karin; Novák, Ondrej

    2018-04-27

    Auxin (indole-3-acetic acid, IAA) plays fundamental roles as a signalling molecule during numerous plant growth and development processes. The formation of local auxin gradients and auxin maxima/minima, which is very important for these processes, is regulated by auxin metabolism (biosynthesis, degradation, and conjugation) as well as transport. When studying auxin metabolism pathways it is crucial to combine data obtained from genetic investigations with the identification and quantification of individual metabolites. Thus, to facilitate efforts to elucidate auxin metabolism and its roles in plants, we have developed a high-throughput method for simultaneously quantifying IAA and its key metabolites in minute samples (<10 mg FW) of Arabidopsis thaliana tissues by in-tip micro solid-phase extraction and fast LC-tandem MS. As a proof of concept, we applied the method to a collection of Arabidopsis mutant lines and identified lines with altered IAA metabolite profiles using multivariate data analysis. Finally, we explored the correlation between IAA metabolite profiles and IAA-related phenotypes. The developed rapid analysis of large numbers of samples (>100 samples d-1) is a valuable tool to screen for novel regulators of auxin metabolism and homeostasis among large collections of genotypes.

  20. Trends and advances in food analysis by real-time polymerase chain reaction.

    PubMed

    Salihah, Nur Thaqifah; Hossain, Mohammad Mosharraf; Lubis, Hamadah; Ahmed, Minhaz Uddin

    2016-05-01

    Analyses to ensure food safety and quality are more relevant now because of rapid changes in the quantity, diversity and mobility of food. Food-contamination must be determined to maintain health and up-hold laws, as well as for ethical and cultural concerns. Real-time polymerase chain reaction (RT-PCR), a rapid and inexpensive quantitative method to detect the presence of targeted DNA-segments in samples, helps in determining both accidental and intentional adulterations of foods by biological contaminants. This review presents recent developments in theory, techniques, and applications of RT-PCR in food analyses, RT-PCR addresses the limitations of traditional food analyses in terms of sensitivity, range of analytes, multiplexing ability, cost, time, and point-of-care applications. A range of targets, including species of plants or animals which are used as food ingredients, food-borne bacteria or viruses, genetically modified organisms, and allergens, even in highly processed foods can be identified by RT-PCR, even at very low concentrations. Microfluidic RT-PCR eliminates the separate sample-processing step to create opportunities for point-of-care analyses. We also cover the challenges related to using RT-PCR for food analyses, such as the need to further improve sample handling.

  1. Nanoscale microstructure effects on hydrogen behavior in rapidly solidified aluminum alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tashlykova-Bushkevich, Iya I.

    2015-12-31

    The present work summarizes recent progress in the investigation of nanoscale microstructure effects on hydrogen behavior in rapidly solidified aluminum alloys foils produced at exceptionally high cooling rates. We focus here on the potential of modification of hydrogen desorption kinetics in respect to weak and strong trapping sites that could serve as hydrogen sinks in Al materials. It is shown that it is important to elucidate the surface microstructure of the Al alloy foils at the submicrometer scale because rapidly solidified microstructural features affect hydrogen trapping at nanostructured defects. We discuss the profound influence of solute atoms on hydrogen−lattice defectmore » interactions in the alloys. with emphasis on role of vacancies in hydrogen evolution; both rapidly solidified pure Al and conventionally processed aluminum samples are considered.« less

  2. Rapid quantitation of atorvastatin in process pharmaceutical powder sample using Raman spectroscopy and evaluation of parameters related to accuracy of analysis.

    PubMed

    Lim, Young-Il; Han, Janghee; Woo, Young-Ah; Kim, Jaejin; Kang, Myung Joo

    2018-07-05

    The purpose of this study was to determine the atorvastatin (ATV) content in process pharmaceutical powder sample using Raman spectroscopy. To establish the analysis method, the influence of the type of Raman measurements (back-scattering or transmission mode), preparation of calibration sample (simple admixing or granulation), sample pre-treatment (pelletization), and spectral pretreatment on the Raman spectra was investigated. The characteristic peak of the active compound was more distinctively detected in transmission Raman mode with a laser spot size of 4mm than in the back-scattering method. Preparation of calibration samples by wet granulation, identical to the actual manufacturing process, provided unchanged spectral patterns for the in process sample, with no changes and/or shifts in the spectrum. Pelletization before Raman analysis remarkably improved spectral reproducibility by decreasing the difference in density between the samples. Probabilistic quotient normalization led to accurate and consistent quantification of the ATV content in the calibration samples (standard error of cross validation: 1.21%). Moreover, the drug content in the granules obtained from five commercial batches were reliably quantified, with no statistical difference (p=0.09) with that obtained by HPLC assay. From these findings, we suggest that transmission Raman analysis may be a fast and non-invasive method for the quantification of ATV in actual manufacturing processes. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Rapid quantitation of atorvastatin in process pharmaceutical powder sample using Raman spectroscopy and evaluation of parameters related to accuracy of analysis

    NASA Astrophysics Data System (ADS)

    Lim, Young-Il; Han, Janghee; Woo, Young-Ah; Kim, Jaejin; Kang, Myung Joo

    2018-07-01

    The purpose of this study was to determine the atorvastatin (ATV) content in process pharmaceutical powder sample using Raman spectroscopy. To establish the analysis method, the influence of the type of Raman measurements (back-scattering or transmission mode), preparation of calibration sample (simple admixing or granulation), sample pre-treatment (pelletization), and spectral pretreatment on the Raman spectra was investigated. The characteristic peak of the active compound was more distinctively detected in transmission Raman mode with a laser spot size of 4 mm than in the back-scattering method. Preparation of calibration samples by wet granulation, identical to the actual manufacturing process, provided unchanged spectral patterns for the in process sample, with no changes and/or shifts in the spectrum. Pelletization before Raman analysis remarkably improved spectral reproducibility by decreasing the difference in density between the samples. Probabilistic quotient normalization led to accurate and consistent quantification of the ATV content in the calibration samples (standard error of cross validation: 1.21%). Moreover, the drug content in the granules obtained from five commercial batches were reliably quantified, with no statistical difference (p = 0.09) with that obtained by HPLC assay. From these findings, we suggest that transmission Raman analysis may be a fast and non-invasive method for the quantification of ATV in actual manufacturing processes.

  4. A Review of Analytical Techniques and Their Application in Disease Diagnosis in Breathomics and Salivaomics Research

    PubMed Central

    Beale, David J.; Jones, Oliver A. H.; Karpe, Avinash V.; Dayalan, Saravanan; Oh, Ding Yuan; Kouremenos, Konstantinos A.; Ahmed, Warish; Palombo, Enzo A.

    2016-01-01

    The application of metabolomics to biological samples has been a key focus in systems biology research, which is aimed at the development of rapid diagnostic methods and the creation of personalized medicine. More recently, there has been a strong focus towards this approach applied to non-invasively acquired samples, such as saliva and exhaled breath. The analysis of these biological samples, in conjunction with other sample types and traditional diagnostic tests, has resulted in faster and more reliable characterization of a range of health disorders and diseases. As the sampling process involved in collecting exhaled breath and saliva is non-intrusive as well as comparatively low-cost and uses a series of widely accepted methods, it provides researchers with easy access to the metabolites secreted by the human body. Owing to its accuracy and rapid nature, metabolomic analysis of saliva and breath (known as salivaomics and breathomics, respectively) is a rapidly growing field and has shown potential to be effective in detecting and diagnosing the early stages of numerous diseases and infections in preclinical studies. This review discusses the various collection and analyses methods currently applied in two of the least used non-invasive sample types in metabolomics, specifically their application in salivaomics and breathomics research. Some of the salient research completed in this field to date is also assessed and discussed in order to provide a basis to advocate their use and possible future scientific directions. PMID:28025547

  5. RAPID DETECTION METHOD FOR E.COLI, ENTEROCOCCI AND BACTEROIDES IN RECREATIONAL WATER

    EPA Science Inventory

    Current methodology for determining fecal contamination of drinking water sources and recreational waters rely on the time-consuming process of bacterial multiplication and require at least 24 hours from the time of sampling to the possible determination that the water is unsafe ...

  6. Gradient elution moving boundary electrophoresis enables rapid analysis of acids in complex biomass-derived streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Munson, Matthew S.; Karp, Eric M.; Nimlos, Claire T.

    Biomass conversion processes such as pretreatment, liquefaction, and pyrolysis often produce complex mixtures of intermediates that are a substantial challenge to analyze rapidly and reliably. To characterize these streams more comprehensively and efficiently, new techniques are needed to track species through biomass deconstruction and conversion processes. Here, we present the application of an emerging analytical method, gradient elution moving boundary electrophoresis (GEMBE), to quantify a suite of acids in a complex, biomass-derived streams from alkaline pretreatment of corn stover. GEMBE offers distinct advantages over common chromatography-spectrometry analytical approaches in terms of analysis time, sample preparation requirements, and cost of equipment.more » As demonstrated here, GEMBE is able to track 17 distinct compounds (oxalate, formate, succinate, malate, acetate, glycolate, protocatechuate, 3-hydroxypropanoate, lactate, glycerate, 2-hydroxybutanoate, 4-hydroxybenzoate, vanillate, p-coumarate, ferulate, sinapate, and acetovanillone). The lower limit of detection was compound dependent and ranged between 0.9 and 3.5 umol/L. Results from GEMBE were similar to recent results from an orthogonal method based on GCxGC-TOF/MS. Altogether, GEMBE offers a rapid, robust approach to analyze complex biomass-derived samples, and given the ease and convenience of deployment, may offer an analytical solution for online tracking of multiple types of biomass streams.« less

  7. Gradient elution moving boundary electrophoresis enables rapid analysis of acids in complex biomass-derived streams

    DOE PAGES

    Munson, Matthew S.; Karp, Eric M.; Nimlos, Claire T.; ...

    2016-09-27

    Biomass conversion processes such as pretreatment, liquefaction, and pyrolysis often produce complex mixtures of intermediates that are a substantial challenge to analyze rapidly and reliably. To characterize these streams more comprehensively and efficiently, new techniques are needed to track species through biomass deconstruction and conversion processes. Here, we present the application of an emerging analytical method, gradient elution moving boundary electrophoresis (GEMBE), to quantify a suite of acids in a complex, biomass-derived streams from alkaline pretreatment of corn stover. GEMBE offers distinct advantages over common chromatography-spectrometry analytical approaches in terms of analysis time, sample preparation requirements, and cost of equipment.more » As demonstrated here, GEMBE is able to track 17 distinct compounds (oxalate, formate, succinate, malate, acetate, glycolate, protocatechuate, 3-hydroxypropanoate, lactate, glycerate, 2-hydroxybutanoate, 4-hydroxybenzoate, vanillate, p-coumarate, ferulate, sinapate, and acetovanillone). The lower limit of detection was compound dependent and ranged between 0.9 and 3.5 umol/L. Results from GEMBE were similar to recent results from an orthogonal method based on GCxGC-TOF/MS. Altogether, GEMBE offers a rapid, robust approach to analyze complex biomass-derived samples, and given the ease and convenience of deployment, may offer an analytical solution for online tracking of multiple types of biomass streams.« less

  8. Analysis of characteristics of Si in blast furnace pig iron and calibration methods in the detection by laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Mei, Yaguang; Cheng, Yuxin; Cheng, Shusen; Hao, Zhongqi; Guo, Lianbo; Li, Xiangyou; Zeng, Xiaoyan

    2017-10-01

    During the iron-making process in blast furnace, the Si content in liquid pig iron was usually used to evaluate the quality of liquid iron and thermal state of blast furnace. None effective method was found for rapid detecting the Si concentration of liquid iron. Laser-induced breakdown spectroscopy (LIBS) is a kind of atomic emission spectrometry technology based on laser ablation. Its obvious advantage is realizing rapid, in-situ, online analysis of element concentration in open air without sample pretreatment. The characteristics of Si in liquid iron were analyzed from the aspect of thermodynamic theory and metallurgical technology. The relationship between Si and C, Mn, S, P or other alloy elements were revealed based on thermodynamic calculation. Subsequently, LIBS was applied on rapid detection of Si of pig iron in this work. During LIBS detection process, several groups of standard pig iron samples were employed in this work to calibrate the Si content in pig iron. The calibration methods including linear, quadratic and cubic internal standard calibration, multivariate linear calibration and partial least squares (PLS) were compared with each other. It revealed that the PLS improved by normalization was the best calibration method for Si detection by LIBS.

  9. Comparison of femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for uranium isotopic measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Havrilla, George Joseph; McIntosh, Kathryn Gallagher; Judge, Elizabeth

    2016-10-20

    Feasibility tests were conducted using femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for rapid uranium isotopic measurements. The samples used in this study consisted of a range of pg quantities of known 235/238 U solutions as dried spot residues of 300 pL drops on silicon substrates. The samples spanned the following enrichments of 235U: 0.5, 1.5, 2, 3, and 15.1%. In this direct comparison using these particular samples both pulse durations demonstrated near equivalent data can be produced on either system with respect to accuracy and precision. There is no question that either LA-ICP-MS method offers themore » potential for rapid, accurate and precise isotopic measurements of U10Mo materials whether DU, LEU or HEU. The LA-ICP-MS equipment used for this work is commercially available. The program is in the process of validating this work for large samples using center samples strips from Y-12 MP-1 LEU-Mo Casting #1.« less

  10. Rapid micromotor-based naked-eye immunoassay.

    PubMed

    de Ávila, Berta Esteban-Fernández; Zhao, Mingjiao; Campuzano, Susana; Ricci, Francesco; Pingarrón, José M; Mascini, Marcello; Wang, Joseph

    2017-05-15

    A dynamic micromotor-based immunoassay, exemplified by cortisol detection, based on the use of tubular micromotors functionalized with a specific antibody is described. The use of antibody-functionalized micromotors offers huge acceleration of both direct and competitive cortisol immunoassays, along with greatly enhanced sensitivity of direct and competitive immunoassays. The dramatically improved speed and sensitivity reflect the greatly increased likelihood of antibody-cortisol contacts and fluid mixing associated with the dynamic movement of these microtube motors and corresponding bubble generation that lead to a highly efficient and rapid recognition process. Rapid naked-eye detection of cortisol in the sample is achieved in connection to use of horseradish peroxidase (HRP) tag and TMB/H 2 O 2 system. Key parameters of the competitive immunoassay (e.g., incubation time and reaction volume) were optimized. This fast visual micromotor-based sensing approach enables "on the move" specific detection of the target cortisol down to 0.1μgmL -1 in just 2min, using ultrasmall (50µL) sample volumes. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Approximate formula for recalescence in binary eutectic alloys

    NASA Technical Reports Server (NTRS)

    Ohsaka, K.; Trinh, E. H.

    1993-01-01

    Supercooling of a liquid prior to the nucleation of a solid and the subsequent rapid growth are necessary conditions for producing novel microstructures including metastable phases which are not formed by conventional solidification processes. Since containerless techniques, such as levitation and free fall of a sample, are capable of achieving a significant supercooling level of liquids, they are under consideration as possible techniques for material processing on earth and in space.

  12. Rapid extraction from and direct identification in clinical samples of methicillin-resistant staphylococci using the PCR.

    PubMed

    Jaffe, R I; Lane, J D; Albury, S V; Niemeyer, D M

    2000-09-01

    Methicillin-resistant staphylococci (MRS) are one of the most common causes of nosocomial infections and bacteremia. Standard bacterial identification and susceptibility testing frequently require as long as 72 h to report results, and there may be difficulty in rapidly and accurately identifying methicillin resistance. The use of the PCR is a rapid and simple process for the amplification of target DNA sequences, which can be used to identify and test bacteria for antimicrobial resistance. However, many sample preparation methods are unsuitable for PCR utilization in the clinical laboratory because they either are not cost-effective, take too long to perform, or do not provide a satisfactory DNA template for PCR. Our goal was to provide same-day results to facilitate rapid diagnosis and therapy. In this report, we describe a rapid method for extraction of bacterial DNA directly from blood culture bottles that gave quality DNA for PCR in as little as 20 min. We compared this extraction method to the standard QIAGEN method for turnaround time (TAT), cost, purity, and use of template in PCR. Specific identification of MRS was determined using intragenic primer sets for bacterial and Staphylococcus 16S rRNA and mecA gene sequences. The PCR primer sets were validated with 416 isolates of staphylococci, including methicillin-resistant Staphylococcus aureus (n = 106), methicillin-sensitive S. aureus (n = 134), and coagulase-negative Staphylococcus (n = 176). The total supply cost of our extraction method and PCR was $2.15 per sample with a result TAT of less than 4 h. The methods described herein represent a rapid and accurate DNA extraction and PCR-based identification system, which makes the system an ideal candidate for use under austere field conditions and one that may have utility in the clinical laboratory.

  13. Solidification of undercooled liquids

    NASA Technical Reports Server (NTRS)

    Perepezko, J. H.; Shiohara, Y.; Paik, J. S.; Flemmings, M. C.

    1982-01-01

    During rapid solidification processing (RSP) the amount of liquid undercooling is an important factor in determining microstructural development by controlling phase selection during nucleation and morphological evolution during crystal growth. While undercooling is an inherent feature of many techniques of RSP, the deepest undercoolings and most controlled studies have been possible in carefully prepared fine droplet samples. From past work and recent advances in studies of nucleation kinetics it has become clear that the initiation of crystallization during RSP is governed usually by heterogeneous sites located at surfaces. With known nucleant sites, it has been possible to identify specific pathways of metastable phase formation and microstructural development in alloys. These advances have allowed for a clearer assessment of the interplay between undercooling, cooling rate and particle size statistics in structure formation. New approaches to the examination of growth processes have been developed to follow the thermal behavior and morphology in small samples in the period of rapid crystallization and recalescence. Based upon the new experimental information from these studies, useful models can be developed for the overall solidification process to include nucleation behavior, thermodynamic constraints, thermal history, growth kinetics, solute redistribution and resulting structures. From the refinement of knowledge concerning the underlying factors that govern RSP a basis is emerging for an effective alloy design and processing strategy.

  14. [Use of MALDI-TOF in the rapid diagnosis of sepsis].

    PubMed

    Carlos Rodríguez, Juan; Ángel Bratos, Miguel; Merino, Esperanza; Ezpeleta, Carmen

    2016-06-01

    The introduction of mass spectrometry through MALDI-TOF (matrix-assisted laser desorption ionization time-of-flight) in the diagnosis of bacteraemia and fungaemia has represented a revolution due to the rapidity and reliability of the results that it can offer to microbiology services and laboratories through analysis of the mass spectrum of the bacterial protein directly from positive blood culture bottles. These data are more useful if they are used in conjunction with other techniques able to identify the antibiotic resistance pattern of the microorganism. There is a need for a process of standardising sample processing protocols and for perfecting the identification of the agents causing bacteraemia, especially in some species of Gram-positive cocci and in polymicrobial processes. The introduction of this methodology provides rapid information that is highly important for the clinical management of bacteraemia. The availability of a multidisciplinary working group that applies all this information quickly and correctly in hospitals will improve the quality of care, reduce antibiotic expenditure and hospital stay and help to control the serious problem of antibiotic resistance. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  15. A rapid method for the simultaneous determination of gross alpha and beta activities in water samples using a low background liquid scintillation counter.

    PubMed

    Sanchez-Cabeza, J A; Pujol, L

    1995-05-01

    The radiological examination of water requires a rapid screening technique that permits the determination of the gross alpha and beta activities of each sample in order to decide if further radiological analyses are necessary. In this work, the use of a low background liquid scintillation system (Quantulus 1220) is proposed to simultaneously determine the gross activities in water samples. Liquid scintillation is compared to more conventional techniques used in most monitoring laboratories. In order to determine the best counting configuration of the system, pulse shape discrimination was optimized for 6 scintillant/vial combinations. It was concluded that the best counting configuration was obtained with the scintillation cocktail Optiphase Hisafe 3 in Zinsser low diffusion vials. The detection limits achieved were 0.012 Bq L-1 and 0.14 Bq L-1 for gross alpha and beta activity respectively, after a 1:10 concentration process by simple evaporation and for a counting time of only 360 min. The proposed technique is rapid, gives spectral information, and is adequate to determine gross activities according to the World Health Organization (WHO) guideline values.

  16. Robofurnace: A semi-automated laboratory chemical vapor deposition system for high-throughput nanomaterial synthesis and process discovery

    PubMed Central

    Oliver, C. Ryan; Westrick, William; Koehler, Jeremy; Brieland-Shoultz, Anna; Anagnostopoulos-Politis, Ilias; Cruz-Gonzalez, Tizoc; Hart, A. John

    2013-01-01

    Laboratory research and development on new materials, such as nanostructured thin films, often utilizes manual equipment such as tube furnaces due to its relatively low cost and ease of setup. However, these systems can be prone to inconsistent outcomes due to variations in standard operating procedures and limitations in performance such as heating and cooling rates restrict the parameter space that can be explored. Perhaps more importantly, maximization of research throughput and the successful and efficient translation of materials processing knowledge to production-scale systems, relies on the attainment of consistent outcomes. In response to this need, we present a semi-automated lab-scale chemical vapor deposition (CVD) furnace system, called “Robofurnace.” Robofurnace is an automated CVD system built around a standard tube furnace, which automates sample insertion and removal and uses motion of the furnace to achieve rapid heating and cooling. The system has a 10-sample magazine and motorized transfer arm, which isolates the samples from the lab atmosphere and enables highly repeatable placement of the sample within the tube. The system is designed to enable continuous operation of the CVD reactor, with asynchronous loading/unloading of samples. To demonstrate its performance, Robofurnace is used to develop a rapid CVD recipe for carbon nanotube (CNT) forest growth, achieving a 10-fold improvement in CNT forest mass density compared to a benchmark recipe using a manual tube furnace. In the long run, multiple systems like Robofurnace may be linked to share data among laboratories by methods such as Twitter. Our hope is Robofurnace and like automation will enable machine learning to optimize and discover relationships in complex material synthesis processes. PMID:24289435

  17. Rapid self-assembly of DNA on a microfluidic chip

    PubMed Central

    Zheng, Yao; Footz, Tim; Manage, Dammika P; Backhouse, Christopher James

    2005-01-01

    Background DNA self-assembly methods have played a major role in enabling methods for acquiring genetic information without having to resort to sequencing, a relatively slow and costly procedure. However, even self-assembly processes tend to be very slow when they rely upon diffusion on a large scale. Miniaturisation and integration therefore hold the promise of greatly increasing this speed of operation. Results We have developed a rapid method for implementing the self-assembly of DNA within a microfluidic system by electrically extracting the DNA from an environment containing an uncharged denaturant. By controlling the parameters of the electrophoretic extraction and subsequent analysis of the DNA we are able to control when the hybridisation occurs as well as the degree of hybridisation. By avoiding off-chip processing or long thermal treatments we are able to perform this hybridisation rapidly and can perform hybridisation, sizing, heteroduplex analysis and single-stranded conformation analysis within a matter of minutes. The rapidity of this analysis allows the sampling of transient effects that may improve the sensitivity of mutation detection. Conclusions We believe that this method will aid the integration of self-assembly methods upon microfluidic chips. The speed of this analysis also appears to provide information upon the dynamics of the self-assembly process. PMID:15717935

  18. SIMPLE MINI-METHOD TO EXTRACT BULK DNA DIRECTLY FROM SOIL FOR USE WITH PCR

    EPA Science Inventory

    A rapid, simple method is described, which yields amplifiable bacterial and fungal DNAs from soil. NA is extracted directly from soil and separated from the soil contaminants by electrophoresis in Nusieve GTG agarose. p to fifty 20 mg samples can be processed in one day.

  19. Application of Rapid Prototyping to the Investment Casting of Test Hardware (MSFC Center Director's Discretionary Fund Final Report, Project No. 98-08)

    NASA Technical Reports Server (NTRS)

    Cooper, K. G.; Wells, D.

    2000-01-01

    Investment casting masters of a selected propulsion hardware component, a fuel pump housing, were rapid prototyped on the several processes in-house, along with the new Z-Corp process acquired through this project. Also, tensile samples were prototyped and cast using the same significant parameters. The models were then shelled in-house using a commercial grade zircon-based slurry and stucco technique. Next, the shelled models were fired and cast by our in-house foundry contractor (IITRI), with NASA-23, a commonly used test hardware metal. The cast models are compared by their surface finish and overall appearance (i.e., the occurrence of pitting, warping, etc.), as well as dimensional accuracy.

  20. Advancing microwave technology for dehydration processing of biologics.

    PubMed

    Cellemme, Stephanie L; Van Vorst, Matthew; Paramore, Elisha; Elliott, Gloria D

    2013-10-01

    Our prior work has shown that microwave processing can be effective as a method for dehydrating cell-based suspensions in preparation for anhydrous storage, yielding homogenous samples with predictable and reproducible drying times. In the current work an optimized microwave-based drying process was developed that expands upon this previous proof-of-concept. Utilization of a commercial microwave (CEM SAM 255, Matthews, NC) enabled continuous drying at variable low power settings. A new turntable was manufactured from Ultra High Molecular Weight Polyethylene (UHMW-PE; Grainger, Lake Forest, IL) to provide for drying of up to 12 samples at a time. The new process enabled rapid and simultaneous drying of multiple samples in containment devices suitable for long-term storage and aseptic rehydration of the sample. To determine sample repeatability and consistency of drying within the microwave cavity, a concentration series of aqueous trehalose solutions were dried for specific intervals and water content assessed using Karl Fischer Titration at the end of each processing period. Samples were dried on Whatman S-14 conjugate release filters (Whatman, Maidestone, UK), a glass fiber membrane used currently in clinical laboratories. The filters were cut to size for use in a 13 mm Swinnex(®) syringe filter holder (Millipore(™), Billerica, MA). Samples of 40 μL volume could be dehydrated to the equilibrium moisture content by continuous processing at 20% with excellent sample-to-sample repeatability. The microwave-assisted procedure enabled high throughput, repeatable drying of multiple samples, in a manner easily adaptable for drying a wide array of biological samples. Depending on the tolerance for sample heating, the drying time can be altered by changing the power level of the microwave unit.

  1. Coniferous forest classification and inventory using Landsat and digital terrain data

    NASA Technical Reports Server (NTRS)

    Franklin, J.; Logan, T. L.; Woodcock, C. E.; Strahler, A. H.

    1986-01-01

    Machine-processing techniques were used in a Forest Classification and Inventory System (FOCIS) procedure to extract and process tonal, textural, and terrain information from registered Landsat multispectral and digital terrain data. Using FOCIS as a basis for stratified sampling, the softwood timber volumes of the Klamath National Forest and Eldorado National Forest were estimated within standard errors of 4.8 and 4.0 percent, respectively. The accuracy of these large-area inventories is comparable to the accuracy yielded by use of conventional timber inventory methods, but, because of automation, the FOCIS inventories are more rapid (9-12 months compared to 2-3 years for conventional manual photointerpretation, map compilation and drafting, field sampling, and data processing) and are less costly.

  2. Determination of epichlorohydrin and 1,3-dichloro-2-propanol in synthesis of cationic etherifying reagent by headspace gas chromatography.

    PubMed

    Tao, Zheng-Yi; Chai, Xin-Sheng; Wu, Shu-Bin

    2011-09-16

    This study demonstrates a headspace gas chromatographic(HS-GC) technique for the determination of residual epichlorohydrin (ECH) and generated 1,3-dichloro-2-propanol (DCP) in synthesis process of 3-chloro-2-hydroxypropyltrimethylammonium chloride (CHTAC). By a weight-based sampling method, coupled with significant dilution in 15.8% sodium sulfate and 0.1% silver nitrate mixed solution rapidly, the sample for HS-GC analysis is prepared. Based on the reaction stoichiometry, the conversion (R) of CHTAC during the synthesis process can be calculated from sampling weight and GC peak area. The results showed that the method has a good measurement precision (RSD<2.5%) and accuracy (recovery=101-104%) for the quantification of both ECH and DCP in the process samples. The present method is simple and accurate, which can be used for the efficient determination of the CHTAC conversion in the synthesis research. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Vaginal Prostate Specific Antigen (PSA) Is a Useful Biomarker of Semen Exposure Among HIV-Infected Ugandan Women.

    PubMed

    Woolf-King, Sarah E; Muyindike, Winnie; Hobbs, Marcia M; Kusasira, Adrine; Fatch, Robin; Emenyonu, Nneka; Johnson, Mallory O; Hahn, Judith A

    2017-07-01

    The practical feasibility of using prostate specific antigen (PSA) as a biomarker of semen exposure was examined among HIV-infected Ugandan women. Vaginal fluids were obtained with self-collected swabs and a qualitative rapid test (ABAcard ® p30) was used to detect PSA. Trained laboratory technicians processed samples on-site and positive PSA tests were compared to self-reported unprotected vaginal sex (UVS) in the last 48 h. A total of 77 women submitted 126 samples for PSA testing at up to three study visits. Of these samples, 31 % (n = 39/126) were PSA positive, and 64 % (n = 25/39) of the positive PSA samples were accompanied by self-report of no UVS at the study visit the PSA was collected. There were no reported difficulties with specimen collection, storage, or processing. These findings provide preliminary data on high levels of misreported UVS among HIV-infected Ugandan women using practically feasible methods for PSA collection and processing.

  4. Reduction Behavior of Assmang and Comilog ore in the SiMn Process

    NASA Astrophysics Data System (ADS)

    Kim, Pyunghwa Peace; Holtan, Joakim; Tangstad, Merete

    The reduction behavior of raw materials from Assmang and Comilog based charges were experimentally investigated with CO gas up to 1600 °C. Quartz, HC FeMn slag or limestone were added to Assmang or Comilog according to the SiMn production charge, and mass loss results were obtained by using a TGA furnace. The results showed that particle size, type of manganese ore and mixture have close relationship to the reduction behavior of raw materials during MnO and SiO2 reduction. The influence of particle size to mass loss was apparent when Assmang or Comilog was mixed with only coke (FeMn) while it became insignificant when quartz and HC FeMn slag (SiMn) were added. This implied that quartz and HC FeMn slag had favored the incipient slag formation regardless of particle size. This explained the similar mass loss tendencies of SiMn charge samples between 1200-1500 °C, contrary to FeMn charge samples where different particle sizes showed significant difference in mass loss. Also, while FeMn charge samples showed progressive mass loss, SiMn charge samples showed diminutive mass loss until 1500 °C. However, rapid mass losses were observed with SiMn charge samples in this study above 1500 °C, and they have occurred at different temperatures. This implied rapid reduction of MnO and SiO2 and the type of ore and addition of HC FeMn slag have significant influence determining these temperatures. The temperatures observed for the rapid mass loss were approximately 1503 °C (Quartz and HC FeMn slag addition in Assmang), 1543 °C (Quartz addition in Assmang) and 1580-1587 °C (Quartz and limestone addition in Comilog), respectively. These temperatures also showed indications of possible SiMn production at process temperatures lower than 1550 °C.

  5. Microwave Processing for Sample Preparation to Evaluate Mitochondrial Ultrastructural Damage in Hemorrhagic Shock

    NASA Astrophysics Data System (ADS)

    Josephsen, Gary D.; Josephsen, Kelly A.; Beilman, Greg J.; Taylor, Jodie H.; Muiler, Kristine E.

    2005-12-01

    This is a report of the adaptation of microwave processing in the preparation of liver biopsies for transmission electron microscopy (TEM) to examine ultrastructural damage of mitochondria in the setting of metabolic stress. Hemorrhagic shock was induced in pigs via 35% total blood volume bleed and a 90-min period of shock followed by resuscitation. Hepatic biopsies were collected before shock and after resuscitation. Following collection, biopsies were processed for TEM by a rapid method involving microwave irradiation (Giberson, 2001). Samples pre- and postshock of each of two animals were viewed and scored using the mitochondrial ultrastructure scoring system (Crouser et al., 2002), a system used to quantify the severity of ultrastructural damage during shock. Results showed evidence of increased ultrastructural damage in the postshock samples, which scored 4.00 and 3.42, versus their preshock controls, which scored 1.18 and 1.27. The results of this analysis were similar to those obtained in another model of shock (Crouser et al., 2002). However, the amount of time used to process the samples was significantly shortened with methods involving microwave irradiation.

  6. Fluorescence Spectroscopy for the Monitoring of Food Processes.

    PubMed

    Ahmad, Muhammad Haseeb; Sahar, Amna; Hitzmann, Bernd

    Different analytical techniques have been used to examine the complexity of food samples. Among them, fluorescence spectroscopy cannot be ignored in developing rapid and non-invasive analytical methodologies. It is one of the most sensitive spectroscopic approaches employed in identification, classification, authentication, quantification, and optimization of different parameters during food handling, processing, and storage and uses different chemometric tools. Chemometrics helps to retrieve useful information from spectral data utilized in the characterization of food samples. This contribution discusses in detail the potential of fluorescence spectroscopy of different foods, such as dairy, meat, fish, eggs, edible oil, cereals, fruit, vegetables, etc., for qualitative and quantitative analysis with different chemometric approaches.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Núñez-Coavas, H.

    As cast Cu{sub 90}Co{sub 10} ribbons rapidly solidified by twin-roller melt spinning, exhibit special microstructure features. This processing method provides scenarios where a different phase selection takes place; coherent Co precipitates form directly from solidification, with neither a spinodal-like composition oscillation nor a discontinuously precipitated laminar phase. Samples are processed at tangential wheel speeds of 10 m/s (V10), 15 m/s (V15), 20 m/s (V20) and 30 m/s (V30). Microstructures resulting from this single step process are characterized and the hysteresis properties and the magnetoresistance effects evaluated. Samples V30 have a quite uniform density of coherent precipitates, with a narrow sizemore » distribution around 4 nm. On contrary, non-uniform precipitate distributions are found in samples cooled at lower rates; zones with a high density of coherent Co-rich precipitates are found forming colonies. These colonies are consistent with the extended compositional fluctuations occurring during very early stages in the cooling process. Samples may exhibit wide (V10) and even bimodal (V15) size distributions. Only samples V30 behave close to the ideal superparamagnetism. Samples V20 present relatively large coercivity and relative remanence and behave as an interacting superparamagnet, while the hysteresis loops of ribbons cooled at lower rates exhibit a ferromagnetic contribution in addition to the superparamagnetic-like one. This ferromagnetic component arises from blocked precipitates, larger than the upper bound size for superparamagnetic behavior at 300 K (12 nm). Room temperature magnetoresistance values associated to granular scattering units decrease as the mean precipitate size increases, but they remain below 2%, which is lower than that measured in samples annealed after rapid solidification, indicating that in this latter case contributions from the spinodally segregated matrix take place in addition to that of Co granules. - Highlights: •Microstructures of twin-rolled Cu{sub 90}Cu{sub 10} alloys are for the first time characterized. •Coherent Co-rich precipitates distribute forming dense colonies inside the grains. •No coexisting multilayer-like structures (spinodal or laminar phases) are detected. •Magnetic hysteresis arises from inter-particle interaction in these dense colonies. •Magnetoresistance level in these purely granular systems is low (1.6% at 300 K).« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Binh T; Lehmann, Johannes C; Kinyangi, James

    Black carbon (BC) is a quantitatively important C pool in the global carbon cycle due to its relative recalcitrance against decay compared with other C pools. However, how rapidly BC is oxidized and in what way the molecular structure changes during decomposition over decadal time scales, is largely unknown. In the present study, the long-term dynamics in quality and quantity of BC were investigated in cultivated soil using X-ray Photoelectron Spectroscopy (XPS), Fourier-Transform Infrared (FTIR) and Nuclear Magnetic Resonance (NMR) techniques. BC particles, obtained from soil samples at 8 conversion ages stretching over 100 years and from a forest soilmore » sample from Kenya, were manually picked under a light microscope for characterization and quantification. BC contents rapidly decreased from 12.7 to 3.8 mg C g⁻¹ soil during the first 30 years since conversion, after which they slowly decreased to a steady state at 3.51 mg C g ⁻¹soil. BC-derived C losses over 100 years were estimated at 6000 kg C ha⁻¹ to a depth of 0.1 m. The initial rapid changes in BC stocks resulted in a mean residence time of only around 8.3 years, which was likely a function of both decomposition as well as transport processes. The molecular properties of BC changed more rapidly on surfaces than in the interior of BC particles and more rapidly during the first 30 years than during the following 70 years. The Oc/C ratios (Oc is O bound to C) and carbonyl groups (C=O) increased over time by 133 and 192 %, respectively, indicating oxidation was an important degradation process controlling BC quality. Al, Si, polysaccharides, and to a lesser extent Fe were rapidly adsorbed on BC particle surfaces within the first few years after BC deposition to soil. The protection by physical and chemical stabilization was apparently sufficient to not only minimize decomposition below detection between 30 and 100 years after deposition, but also physical export by erosion and vertical transport below 0.1 m.« less

  9. Algal and water-quality data for Rapid Creek and Canyon Lake near Rapid City, South Dakota, 2007

    USGS Publications Warehouse

    Hoogestraat, Galen K.; Putnam, Larry D.; Graham, Jennifer L.

    2008-01-01

    This report summarizes the results of algae and water-quality sampling on Rapid Creek and Canyon Lake during May and September 2007. The overall purpose of the study was to determine the algal community composition of Rapid Creek and Canyon Lake in relation to organisms that are known producers of unwanted tastes and odors in drinking-water supplies. Algal assemblage structure (phytoplankton and periphyton) was examined at 16 sites on Rapid Creek and Canyon Lake during May and September 2007, and actinomycetes bacteria were sampled at the Rapid City water treatment plant intake in May 2007, to determine if taste-and-odor producing organisms were present. During the May 2007 sampling, 3 Rapid Creek sites and 4 Canyon Lake sites were quantitatively sampled for phytoplankton in the water column, 7 Rapid Creek sites were quantitatively sampled for attached periphyton, and 4 lake and retention pond sites were qualitatively sampled for periphyton. Five Rapid Creek sites were sampled for geosmin and 2-methylisoborneol, two common taste-and-odor causing compounds known to affect water supplies. During the September 2007 sampling, 4 Rapid Creek sites were quantitatively sampled for attached periphyton, and 3 Canyon Lake sites were qualitatively sampled for periphyton. Water temperature, dissolved oxygen, pH, and specific conductance were measured during each sampling event. Methods of collection and sample analysis are presented for the various types of biological and chemical constituent samples. Diatoms comprised 91-100 percent of the total algal biovolume in periphyton samples collected during May and September. Cyanobacteria (also called blue-green algae) were detected in 7 of the 11 quantitative periphyton samples and ranged from 0.01 to 2.0 percent of the total biovolume. Cyanobacteria were present in 3 of the 7 phytoplankton samples collected in May, but the relative biovolumes were small (0.01-0.2 percent). Six of seven qualitative samples collected from Canyon Lake and retention ponds during May and September also contained cyanobacteria. Geosmin and 2-methylisoborneol concentrations were less than detection limits (0.005 ug/L) in all five of the Rapid Creek samples collected in May. Actinomycetes bacteria were present at the water treatment plant intake in May 2007, at a concentration of 6 colonies per milliliter. During this study, no taste-and-odor problems with the drinking water within the study area were reported. However, the presence of cyanobacterial taxa known to contain taste-and-odor producing strains (such as Leptolyngbya, Phormidium, and Anabaena) indicates the potential for taste-and-odor problems under certain physical and chemical conditions.

  10. Creating Sub-50 nm Nanofluidic Junctions in PDMS Microchip via Self-Assembly Process of Colloidal Silica Beads for Electrokinetic Concentration of Biomolecules

    PubMed Central

    Syed, A.; Mangano, L.; Mao, P.; Han, J.

    2014-01-01

    In this work we describe a novel and simple self-assembly of colloidal silica beads to create nanofluidic junction between two microchannels. The nanoporous membrane was used to induce ion concentration polarization inside the microchannel and this electrokinetic preconcentration system allowed rapid concentration of DNA samples by ∼1700 times and protein samples by ∼100 times within 5 minutes. PMID:25254651

  11. Screening Antioxidants Using LC-MS: A Case Study with Cocoa

    PubMed Central

    Calderón, Angela I.; Wright, Brian J.; Hurst, W. Jeffrey; van Breemen, Richard B.

    2009-01-01

    Oxidative stress enhances pathological processes contributing to cancer, cardiovascular disease and neurodegenerative diseases, and dietary antioxidants may counteract these deleterious processes. Since rapid methods to evaluate and compare food products for antioxidant benefits are needed, a new assay based on liquid chromatography-mass spectrometry (LC-MS) was developed for the identification and quantitative analysis of antioxidants in complex natural product samples such as food extracts. This assay is based on the comparison of electrospray LC-MS profiles of sample extracts before and after treatment with reactive oxygen species such as hydrogen peroxide or DPPH (2,2-diphenyl-1-picrylhydrazyl radical). Using this assay, methanolic extracts of cocoa powder were analyzed, and procyanidins were found to be the most potent antioxidant species. These species were identified using LC-MS, LC-MS-MS, accurate mass measurement, and comparison with reference standards. Furthermore, LC-MS was used to determine the levels of these species in cocoa samples. Catechin and epicatechin were the most abundant antioxidants followed by their dimers and trimers. The most potent antioxidants in cocoa were trimers and dimers of catechin and epicatechin, such as procyanidin B2, followed by catechin and epicatechin. This new LC-MS assay facilitates the rapid identification and then the determination of the relative antioxidant activities of individual antioxidant species in complex natural product samples and food products such as cocoa. PMID:19489609

  12. Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Saima, E-mail: saima.ali@aalto.fi; Hannula, Simo-Pekka

    Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO{sub 4}) solution (Process 1), and ethylene glycol (EG) mixture with HClO{sub 4} and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted tomore » nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25–600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m{sup 2} g{sup −1} is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes. - Graphical abstract: Titania nanotube powders prepared by Process 1 and Process 2 have different crystal structure and specific surface area. - Highlights: • Titania nanotube (TNT) powder is prepared in low water organic electrolyte. • Characterization of TNT powders prepared from aqueous and organic electrolyte. • TNTs prepared by Process 1 are crystalline with higher specific surface area. • TNTs obtained by Process 2 have carbonaceous impurities in the structure.« less

  13. Quality assessment of baby food made of different pre-processed organic raw materials under industrial processing conditions.

    PubMed

    Seidel, Kathrin; Kahl, Johannes; Paoletti, Flavio; Birlouez, Ines; Busscher, Nicolaas; Kretzschmar, Ursula; Särkkä-Tirkkonen, Marjo; Seljåsen, Randi; Sinesio, Fiorella; Torp, Torfinn; Baiamonte, Irene

    2015-02-01

    The market for processed food is rapidly growing. The industry needs methods for "processing with care" leading to high quality products in order to meet consumers' expectations. Processing influences the quality of the finished product through various factors. In carrot baby food, these are the raw material, the pre-processing and storage treatments as well as the processing conditions. In this study, a quality assessment was performed on baby food made from different pre-processed raw materials. The experiments were carried out under industrial conditions using fresh, frozen and stored organic carrots as raw material. Statistically significant differences were found for sensory attributes among the three autoclaved puree samples (e.g. overall odour F = 90.72, p < 0.001). Samples processed from frozen carrots show increased moisture content and decrease of several chemical constituents. Biocrystallization identified changes between replications of the cooking. Pre-treatment of raw material has a significant influence on the final quality of the baby food.

  14. Emerging non-invasive Raman methods in process control and forensic applications.

    PubMed

    Macleod, Neil A; Matousek, Pavel

    2008-10-01

    This article reviews emerging Raman techniques (Spatially Offset and Transmission Raman Spectroscopy) for non-invasive, sub-surface probing in process control and forensic applications. New capabilities offered by these methods are discussed and several application examples are given including the non-invasive detection of counterfeit drugs through blister packs and opaque plastic bottles and the rapid quantitative analysis of the bulk content of pharmaceutical tablets and capsules without sub-sampling.

  15. Development and Validation of a Real-Time PCR Assay for Rapid Detection of Candida auris from Surveillance Samples

    PubMed Central

    Leach, L.; Zhu, Y.

    2017-01-01

    ABSTRACT Candida auris is an emerging multidrug-resistant yeast causing invasive health care-associated infection with high mortality worldwide. Rapid identification of C. auris is of primary importance for the implementation of public health measures to control the spread of infection. To achieve these goals, we developed and validated a TaqMan-based real-time PCR assay targeting the internal transcribed spacer 2 (ITS2) region of the ribosomal gene. The assay was highly specific, reproducible, and sensitive, with the detection limit of 1 C. auris CFU/PCR. The performance of the C. auris real-time PCR assay was evaluated by using 623 surveillance samples, including 365 patient swabs and 258 environmental sponges. Real-time PCR yielded positive results from 49 swab and 58 sponge samples, with 89% and 100% clinical sensitivity with regard to their respective culture-positive results. The real-time PCR also detected C. auris DNA from 1% and 12% of swab and sponge samples with culture-negative results, indicating the presence of dead or culture-impaired C. auris. The real-time PCR yielded results within 4 h of sample processing, compared to 4 to 14 days for culture, reducing turnaround time significantly. The new real-time PCR assay allows for accurate and rapid screening of C. auris and can increase effective control and prevention of this emerging multidrug-resistant fungal pathogen in health care facilities. PMID:29187562

  16. Development and Validation of a Real-Time PCR Assay for Rapid Detection of Candida auris from Surveillance Samples.

    PubMed

    Leach, L; Zhu, Y; Chaturvedi, S

    2018-02-01

    Candida auris is an emerging multidrug-resistant yeast causing invasive health care-associated infection with high mortality worldwide. Rapid identification of C. auris is of primary importance for the implementation of public health measures to control the spread of infection. To achieve these goals, we developed and validated a TaqMan-based real-time PCR assay targeting the internal transcribed spacer 2 ( ITS 2) region of the ribosomal gene. The assay was highly specific, reproducible, and sensitive, with the detection limit of 1 C. auris CFU/PCR. The performance of the C. auris real-time PCR assay was evaluated by using 623 surveillance samples, including 365 patient swabs and 258 environmental sponges. Real-time PCR yielded positive results from 49 swab and 58 sponge samples, with 89% and 100% clinical sensitivity with regard to their respective culture-positive results. The real-time PCR also detected C. auris DNA from 1% and 12% of swab and sponge samples with culture-negative results, indicating the presence of dead or culture-impaired C. auris The real-time PCR yielded results within 4 h of sample processing, compared to 4 to 14 days for culture, reducing turnaround time significantly. The new real-time PCR assay allows for accurate and rapid screening of C. auris and can increase effective control and prevention of this emerging multidrug-resistant fungal pathogen in health care facilities. Copyright © 2018 Leach et al.

  17. Air Flow and Pressure Drop Measurements Across Porous Oxides

    NASA Technical Reports Server (NTRS)

    Fox, Dennis S.; Cuy, Michael D.; Werner, Roger A.

    2008-01-01

    This report summarizes the results of air flow tests across eight porous, open cell ceramic oxide samples. During ceramic specimen processing, the porosity was formed using the sacrificial template technique, with two different sizes of polystyrene beads used for the template. The samples were initially supplied with thicknesses ranging from 0.14 to 0.20 in. (0.35 to 0.50 cm) and nonuniform backside morphology (some areas dense, some porous). Samples were therefore ground to a thickness of 0.12 to 0.14 in. (0.30 to 0.35 cm) using dry 120 grit SiC paper. Pressure drop versus air flow is reported. Comparisons of samples with thickness variations are made, as are pressure drop estimates. As the density of the ceramic material increases the maximum corrected flow decreases rapidly. Future sample sets should be supplied with samples of similar thickness and having uniform surface morphology. This would allow a more consistent determination of air flow versus processing parameters and the resulting porosity size and distribution.

  18. Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Candido; Nichols, Kevin

    2013-11-27

    This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility.more » In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.« less

  19. Assessment of household preparedness through training exercises--two metropolitan counties, Tennessee, 2011.

    PubMed

    2012-09-14

    Public health emergency preparedness involves improving both workforce and household capacity to manage disasters. To improve preparedness at both levels, the Tennessee Department of Health (TDH) formed a Rapid Assessment of Populations Impacted by Disasters (RAPID) team. In 2011, the team used Community Assessment for Public Health Emergency Response (CASPER) two-stage cluster sampling methodology to measure household preparedness for disasters or emergencies in two metropolitan counties. In the two counties, 23% and 31% of households reported being "well-prepared" to handle disasters or emergencies, 43% and 44% reported being "somewhat prepared," and 25% and 20% reported being "not at all prepared." As a result of this experience, RAPID teams were able to improve their methods, streamline processes, and create a better community assessment toolkit. To increase preparedness at both the community and workforce levels, public health departments should assess community preparedness to inform the planning process and provide field training and exercise opportunities for public health workers.

  20. Detection of biological contaminants on foods and food surfaces using laser-induced breakdown spectroscopy (LIBS).

    PubMed

    Multari, Rosalie A; Cremers, David A; Dupre, Jo Anne M; Gustafson, John E

    2013-09-11

    The rapid detection of biological contaminants, such as Escherichia coli O157:H7 and Salmonella enterica , on foods and food-processing surfaces is important to ensure food safety and streamline the food-monitoring process. Laser-induced breakdown spectroscopy (LIBS) is an ideal candidate technology for this application because sample preparation is minimal and results are available rapidly (seconds to minutes). Here, multivariate regression analysis of LIBS data is used to differentiate the live bacterial pathogens E. coli O157:H7 and S. enterica on various foods (eggshell, milk, bologna, ground beef, chicken, and lettuce) and surfaces (metal drain strainer and cutting board). The type (E. coli or S. enterica) of bacteria could be differentiated in all cases studied along with the metabolic state (viable or heat killed). This study provides data showing the potential of LIBS for the rapid identification of biological contaminants using spectra collected directly from foods and surfaces.

  1. Perception SoC Based on an Ultrasonic Array of Sensors: Efficient DSP Core Implementation and Subsequent Experimental Results

    NASA Astrophysics Data System (ADS)

    Kassem, A.; Sawan, M.; Boukadoum, M.; Haidar, A.

    2005-12-01

    We are concerned with the design, implementation, and validation of a perception SoC based on an ultrasonic array of sensors. The proposed SoC is dedicated to ultrasonic echography applications. A rapid prototyping platform is used to implement and validate the new architecture of the digital signal processing (DSP) core. The proposed DSP core efficiently integrates all of the necessary ultrasonic B-mode processing modules. It includes digital beamforming, quadrature demodulation of RF signals, digital filtering, and envelope detection of the received signals. This system handles 128 scan lines and 6400 samples per scan line with a[InlineEquation not available: see fulltext.] angle of view span. The design uses a minimum size lookup memory to store the initial scan information. Rapid prototyping using an ARM/FPGA combination is used to validate the operation of the described system. This system offers significant advantages of portability and a rapid time to market.

  2. Nondestructive detection of pork comprehensive quality based on spectroscopy and support vector machine

    NASA Astrophysics Data System (ADS)

    Liu, Yuanyuan; Peng, Yankun; Zhang, Leilei; Dhakal, Sagar; Wang, Caiping

    2014-05-01

    Pork is one of the highly consumed meat item in the world. With growing improvement of living standard, concerned stakeholders including consumers and regulatory body pay more attention to comprehensive quality of fresh pork. Different analytical-laboratory based technologies exist to determine quality attributes of pork. However, none of the technologies are able to meet industrial desire of rapid and non-destructive technological development. Current study used optical instrument as a rapid and non-destructive tool to classify 24 h-aged pork longissimus dorsi samples into three kinds of meat (PSE, Normal and DFD), on the basis of color L* and pH24. Total of 66 samples were used in the experiment. Optical system based on Vis/NIR spectral acquisition system (300-1100 nm) was self- developed in laboratory to acquire spectral signal of pork samples. Median smoothing filter (M-filter) and multiplication scatter correction (MSC) was used to remove spectral noise and signal drift. Support vector machine (SVM) prediction model was developed to classify the samples based on their comprehensive qualities. The results showed that the classification model is highly correlated with the actual quality parameters with classification accuracy more than 85%. The system developed in this study being simple and easy to use, results being promising, the system can be used in meat processing industry for real time, non-destructive and rapid detection of pork qualities in future.

  3. Development of a fluorescence-based sensor for rapid diagnosis of cyanide exposure.

    PubMed

    Jackson, Randy; Oda, Robert P; Bhandari, Raj K; Mahon, Sari B; Brenner, Matthew; Rockwood, Gary A; Logue, Brian A

    2014-02-04

    Although commonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes in areas such as mining, electroplating, and synthetic fiber production. The "heavy" use of cyanide in these industries, along with its necessary transportation, increases the possibility of human exposure. Because the onset of cyanide toxicity is fast, a rapid, sensitive, and accurate method for the diagnosis of cyanide exposure is necessary. Therefore, a field sensor for the diagnosis of cyanide exposure was developed based on the reaction of naphthalene dialdehyde, taurine, and cyanide, yielding a fluorescent β-isoindole. An integrated cyanide capture "apparatus", consisting of sample and cyanide capture chambers, allowed rapid separation of cyanide from blood samples. Rabbit whole blood was added to the sample chamber, acidified, and the HCN gas evolved was actively transferred through a stainless steel channel to the capture chamber containing a basic solution of naphthalene dialdehyde (NDA) and taurine. The overall analysis time (including the addition of the sample) was <3 min, the linear range was 3.13-200 μM, and the limit of detection was 0.78 μM. None of the potential interferents investigated (NaHS, NH4OH, NaSCN, and human serum albumin) produced a signal that could be interpreted as a false positive or a false negative for cyanide exposure. Most importantly, the sensor was 100% accurate in diagnosing cyanide poisoning for acutely exposed rabbits.

  4. Analysis of Total Oil and Fatty Acids Composition by Near Infrared Reflectance Spectroscopy in Edible Nuts

    USDA-ARS?s Scientific Manuscript database

    Near Infrared (NIR) Reflectance spectroscopy has established itself as an important tool in quantifying water and oil present in various food materials. It is rapid and nondestructive, easier to use, and does not require processing the samples with corrosive chemicals that would render them non-edib...

  5. Cloud-enabled microscopy and droplet microfluidic platform for specific detection of Escherichia coli in water.

    PubMed

    Golberg, Alexander; Linshiz, Gregory; Kravets, Ilia; Stawski, Nina; Hillson, Nathan J; Yarmush, Martin L; Marks, Robert S; Konry, Tania

    2014-01-01

    We report an all-in-one platform - ScanDrop - for the rapid and specific capture, detection, and identification of bacteria in drinking water. The ScanDrop platform integrates droplet microfluidics, a portable imaging system, and cloud-based control software and data storage. The cloud-based control software and data storage enables robotic image acquisition, remote image processing, and rapid data sharing. These features form a "cloud" network for water quality monitoring. We have demonstrated the capability of ScanDrop to perform water quality monitoring via the detection of an indicator coliform bacterium, Escherichia coli, in drinking water contaminated with feces. Magnetic beads conjugated with antibodies to E. coli antigen were used to selectively capture and isolate specific bacteria from water samples. The bead-captured bacteria were co-encapsulated in pico-liter droplets with fluorescently-labeled anti-E. coli antibodies, and imaged with an automated custom designed fluorescence microscope. The entire water quality diagnostic process required 8 hours from sample collection to online-accessible results compared with 2-4 days for other currently available standard detection methods.

  6. Cloud-Enabled Microscopy and Droplet Microfluidic Platform for Specific Detection of Escherichia coli in Water

    PubMed Central

    Kravets, Ilia; Stawski, Nina; Hillson, Nathan J.; Yarmush, Martin L.; Marks, Robert S.; Konry, Tania

    2014-01-01

    We report an all-in-one platform – ScanDrop – for the rapid and specific capture, detection, and identification of bacteria in drinking water. The ScanDrop platform integrates droplet microfluidics, a portable imaging system, and cloud-based control software and data storage. The cloud-based control software and data storage enables robotic image acquisition, remote image processing, and rapid data sharing. These features form a “cloud” network for water quality monitoring. We have demonstrated the capability of ScanDrop to perform water quality monitoring via the detection of an indicator coliform bacterium, Escherichia coli, in drinking water contaminated with feces. Magnetic beads conjugated with antibodies to E. coli antigen were used to selectively capture and isolate specific bacteria from water samples. The bead-captured bacteria were co-encapsulated in pico-liter droplets with fluorescently-labeled anti-E. coli antibodies, and imaged with an automated custom designed fluorescence microscope. The entire water quality diagnostic process required 8 hours from sample collection to online-accessible results compared with 2–4 days for other currently available standard detection methods. PMID:24475107

  7. Accurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioning

    PubMed Central

    Silva, Susana F.; Domingues, José Paulo

    2018-01-01

    Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed. PMID:29599938

  8. Accurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioning.

    PubMed

    Silva, Susana F; Domingues, José Paulo; Morgado, António Miguel

    2018-01-01

    Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed.

  9. Rapid estimation of organic nitrogen in oil shale waste waters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, B.M.; Daughton, C.G.; Harris, G.J.

    1984-04-01

    Many of the characteristics of oil shale process waste waters (e.g., malodors, color, and resistance to biotreatment) are imparted by numerous nitrogenous heterocycles and aromatic amines. For the frequent performance assessment of waste treatment processes designed to remove these nitrogenous organic compounds, a rapid and colligative measurement of organic nitrogen is essential. Quantification of organic nitrogen in biological and agricultural samples is usually accomplished using the time-consuming, wet-chemical Kjeldahl method. For oil shale waste waters, whose primary inorganic nitorgen constituent is amonia, organic Kjeldahl nitrogen (OKN) is determined by first eliminating the endogenous ammonia by distillation and then digesting themore » sample in boiling H/sub 2/SO/sub 4/. The organic material is oxidized, and most forms of organically bound nitrogen are released as ammonium ion. After the addition of base, the ammonia is separated from the digestate by distillation and quantified by acidimetric titrimetry or colorimetry. The major failings of this method are the loss of volatile species such as aliphatic amines (during predistillation) and the inability to completely recover nitrogen from many nitrogenous heterocycles (during digestion). Within the last decade, a new approach has been developed for the quantification of total nitrogen (TN). The sample is first combusted, a« less

  10. Accessing thermoplastic processing windows in metallic glasses using rapid capacitive discharge

    PubMed Central

    Kaltenboeck, Georg; Harris, Thomas; Sun, Kerry; Tran, Thomas; Chang, Gregory; Schramm, Joseph P.; Demetriou, Marios D.; Johnson, William L.

    2014-01-01

    The ability of the rapid-capacitive discharge approach to access optimal viscosity ranges in metallic glasses for thermoplastic processing is explored. Using high-speed thermal imaging, the heating uniformity and stability against crystallization of Zr35Ti30Cu7.5Be27.5 metallic glass heated deeply into the supercooled region is investigated. The method enables homogeneous volumetric heating of bulk samples throughout the entire supercooled liquid region at high rates (~105 K/s) sufficient to bypass crystallization throughout. The crystallization onsets at temperatures in the vicinity of the “crystallization nose” were identified and a Time-Temperature-Transformation diagram is constructed, revealing a “critical heating rate” for the metallic glass of ~1000 K/s. Thermoplastic process windows in the optimal viscosity range of 100–104 Pa·s are identified, being confined between the glass relaxation and the eutectic crystallization transition. Within this process window, near-net forging of a fine precision metallic glass part is demonstrated. PMID:25269892

  11. Protocol for Detection of Yersinia pestis in Environmental ...

    EPA Pesticide Factsheets

    Methods Report This is the first ever open-access and detailed protocol available to all government departments and agencies, and their contractors to detect Yersinia pestis, the pathogen that causes plague, from multiple environmental sample types including water. Each analytical method includes sample processing procedure for each sample type in a step-by-step manner. It includes real-time PCR, traditional microbiological culture, and the Rapid Viability PCR (RV-PCR) analytical methods. For large volume water samples it also includes an ultra-filtration-based sample concentration procedure. Because of such a non-restrictive availability of this protocol to all government departments and agencies, and their contractors, the nation will now have increased laboratory capacity to analyze large number of samples during a wide-area plague incident.

  12. Pyrosequencing-based validation of a simple cell-suspension polymerase chain reaction assay for Campylobacter with application of high-processivity polymerase and novel internal amplification controls for rapid and specific detection.

    PubMed

    Oakley, Brian B; Line, J Eric; Berrang, Mark E; Johnson, Jessica M; Buhr, R Jeff; Cox, Nelson A; Hiett, Kelli L; Seal, Bruce S

    2012-02-01

    Although Campylobacter is an important food-borne human pathogen, there remains a lack of molecular diagnostic assays that are simple to use, cost-effective, and provide rapid results in research, clinical, or regulatory laboratories. Of the numerous Campylobacter assays that do exist, to our knowledge none has been empirically tested for specificity using high-throughput sequencing. Here we demonstrate the power of next-generation sequencing to determine the specificity of a widely cited Campylobacter-specific polymerase chain reaction (PCR) assay and describe a rapid method for direct cell suspension PCR to quickly and easily screen samples for Campylobacter. We present a specific protocol which eliminates the need for time-consuming and expensive genomic DNA extractions and, using a high-processivity polymerase, demonstrate conclusive screening of samples in <1 h. Pyrosequencing results show the assay to be extremely (>99%) sensitive, and spike-back experiments demonstrated a detection threshold of <10(2) CFU mL(-1). Additionally, we present 2 newly designed broad-range bacterial primer sets targeting the 23S rRNA gene that have wide applicability as internal amplification controls. Empirical testing of putative taxon-specific assays using high-throughput sequencing is an important validation step that is now financially feasible for research, regulatory, or clinical applications. Published by Elsevier Inc.

  13. Interleukin-6 Detection with a Plasmonic Chip

    NASA Astrophysics Data System (ADS)

    Tawa, Keiko; Sumiya, Masashi; Toma, Mana; Sasakawa, Chisato; Sujino, Takuma; Miyaki, Tatsuki; Nakazawa, Hikaru; Umetsu, Mitsuo

    Interleukin-6, a cytokine relating inflammatory and autoimmune activity, was detected with three fluorescence assays using a plasmonic chip. In their assays, the way of surface modification, sample volume, incubation time and mixing solution, were found to influence the detection sensitivity. When the assay was revised in the point of a rapid and easy process, the detection sensitivity was not compromised compared to assays with sufficient sample volume and assay time. To suit the purpose of immunosensing, the assay conditions should be determined.

  14. Nuclear Magnetic Resonance Spectroscopy-Based Identification of Yeast.

    PubMed

    Himmelreich, Uwe; Sorrell, Tania C; Daniel, Heide-Marie

    2017-01-01

    Rapid and robust high-throughput identification of environmental, industrial, or clinical yeast isolates is important whenever relatively large numbers of samples need to be processed in a cost-efficient way. Nuclear magnetic resonance (NMR) spectroscopy generates complex data based on metabolite profiles, chemical composition and possibly on medium consumption, which can not only be used for the assessment of metabolic pathways but also for accurate identification of yeast down to the subspecies level. Initial results on NMR based yeast identification where comparable with conventional and DNA-based identification. Potential advantages of NMR spectroscopy in mycological laboratories include not only accurate identification but also the potential of automated sample delivery, automated analysis using computer-based methods, rapid turnaround time, high throughput, and low running costs.We describe here the sample preparation, data acquisition and analysis for NMR-based yeast identification. In addition, a roadmap for the development of classification strategies is given that will result in the acquisition of a database and analysis algorithms for yeast identification in different environments.

  15. Creating Turbulent Flow Realizations with Generative Adversarial Networks

    NASA Astrophysics Data System (ADS)

    King, Ryan; Graf, Peter; Chertkov, Michael

    2017-11-01

    Generating valid inflow conditions is a crucial, yet computationally expensive, step in unsteady turbulent flow simulations. We demonstrate a new technique for rapid generation of turbulent inflow realizations that leverages recent advances in machine learning for image generation using a deep convolutional generative adversarial network (DCGAN). The DCGAN is an unsupervised machine learning technique consisting of two competing neural networks that are trained against each other using backpropagation. One network, the generator, tries to produce samples from the true distribution of states, while the discriminator tries to distinguish between true and synthetic samples. We present results from a fully-trained DCGAN that is able to rapidly draw random samples from the full distribution of possible inflow states without needing to solve the Navier-Stokes equations, eliminating the costly process of spinning up inflow turbulence. This suggests a new paradigm in physics informed machine learning where the turbulence physics can be encoded in either the discriminator or generator. Finally, we also propose additional applications such as feature identification and subgrid scale modeling.

  16. Recuit thermique rapide de semi-conducteur par énergie micro-onde

    NASA Astrophysics Data System (ADS)

    Covas, M.; Gay, H. C.

    1993-05-01

    This paper proposes a new technique for rapid thermal annealing of semi-conductors. This technique is based on microwave energy, and offers the same advantages as the rapid thermal annealing by incoherent light, in terms of rapidity, and contamination. However, our technique reduces considerably the required energy for the annealing process. This technique has been compared to the rapid thermal by incoherent light: lab experiments, carried out on boron implanted silicon samples, showed that a power gain ratio of about 10 can be achieved. Nous proposons une méthode de recuit thermique rapide du silicium par énergie micro-onde. Cette technique offre les mêmes avantages que les traitements thermiques rapides par lumière incohérente, c'est-à-dire des durées de chauffage très brèves, limitant ainsi la diffusion des dopants, et un traitement plaquette par plaquette : les risques de contamination de tout un lot sont ainsi éliminés. De plus notre méthode requiert une faible énergie : pour parvenir à des recuits de qualité similaire à celle obtenue dans des fours de recuit rapide à lampes il faut un flux de puissance 10 fois plus faible.

  17. Investigation of acrylamide formation on bakery products using a crust-like model.

    PubMed

    Açar, Ozge C; Gökmen, Vural

    2009-12-01

    Baking is a complex process where a temperature gradient occurs within the product as a result of simultaneous heat and mass transfers. This behaviour makes the physical parameters (baking temperature and product dimensions) as effective as the chemical parameters on the rate of acrylamide formation in bakery foods. In this study, the change of temperature in different locations of the sample was shown as influenced by the product thickness. The temperature values were close to each other in the sample having thickness of 1 mm (crust model). The product temperature rapidly increased to the oven temperature. A temperature gradient was recorded in the sample having a thickness of 10 mm. As a result, the product temperature did not exceed 100 degrees C within a baking time of 30 min. The product thickness significantly influenced the rate of acrylamide formation during baking. Acrylamide concentration rapidly increased to 411+/-49 ng/g within 8 min in the crust model sample. However, no acrylamide was detected in the thicker sample within 15 min under the same conditions, because the moisture content was still above 10%. The crust model was considered useful to test the effectiveness of different mitigation strategies in bakery foods.

  18. Chemometrics-based process analytical technology (PAT) tools: applications and adaptation in pharmaceutical and biopharmaceutical industries.

    PubMed

    Challa, Shruthi; Potumarthi, Ravichandra

    2013-01-01

    Process analytical technology (PAT) is used to monitor and control critical process parameters in raw materials and in-process products to maintain the critical quality attributes and build quality into the product. Process analytical technology can be successfully implemented in pharmaceutical and biopharmaceutical industries not only to impart quality into the products but also to prevent out-of-specifications and improve the productivity. PAT implementation eliminates the drawbacks of traditional methods which involves excessive sampling and facilitates rapid testing through direct sampling without any destruction of sample. However, to successfully adapt PAT tools into pharmaceutical and biopharmaceutical environment, thorough understanding of the process is needed along with mathematical and statistical tools to analyze large multidimensional spectral data generated by PAT tools. Chemometrics is a chemical discipline which incorporates both statistical and mathematical methods to obtain and analyze relevant information from PAT spectral tools. Applications of commonly used PAT tools in combination with appropriate chemometric method along with their advantages and working principle are discussed. Finally, systematic application of PAT tools in biopharmaceutical environment to control critical process parameters for achieving product quality is diagrammatically represented.

  19. Authentication of processed meat products by peptidomic analysis using rapid ambient mass spectrometry.

    PubMed

    Montowska, Magdalena; Alexander, Morgan R; Tucker, Gregory A; Barrett, David A

    2015-11-15

    We present the application of a novel ambient LESA-MS method for the authentication of processed meat products. A set of 25 species and protein-specific heat stable peptide markers has been detected in processed samples manufactured from beef, pork, horse, chicken and turkey meat. We demonstrate that several peptides derived from myofibrillar and sarcoplasmic proteins are sufficiently resistant to processing to serve as specific markers of processed products. The LESA-MS technique required minimal sample preparation without fractionation and enabled the unambiguous and simultaneous identification of skeletal muscle proteins and peptides as well as other components of animal origin, including the milk protein such as casein alpha-S1, in whole meat product digests. We have identified, for the first time, six fast type II and five slow/cardiac type I MHC peptide markers in various processed meat products. The study demonstrates that complex mixtures of processed proteins/peptides can be examined effectively using this approach. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Tropical Processes Applications for CYGNSS

    NASA Technical Reports Server (NTRS)

    Lang, Timothy J.

    2017-01-01

    The Cyclone Global Navigation Satellite System (CYGNSS) is focused primarily on observing extreme winds in the inner core of tropical cyclones But... Named storms will occur in view of CYGNSS constellation for only a small percentage of the time on orbit And... Rapid-update, all-weather sampling of wind speeds has many other applications in Tropical Meteorology So... Many potential tropical processes applications for CYGNSS were identified in previous Workshop - Let's revisit some of these possibilities now that the mission is up.

  1. Towards rapid prototyped convective microfluidic DNA amplification platform

    NASA Astrophysics Data System (ADS)

    Ajit, Smrithi; Praveen, Hemanth Mithun; Puneeth, S. B.; Dave, Abhishek; Sesham, Bharat; Mohan, K. N.; Goel, Sanket

    2017-02-01

    Today, Polymerase Chain Reaction (PCR) based DNA amplification plays an indispensable role in the field of biomedical research. Its inherent ability to exponentially amplify sample DNA has proven useful for the identification of virulent pathogens like those causing Multiple Drug-Resistant Tuberculosis (MDR-TB). The intervention of Microfluidics technology has revolutionized the concept of PCR from being a laborious and time consuming process into one that is faster, easily portable and capable of being multifunctional. The Microfluidics based PCR outweighs its traditional counterpart in terms of flexibility of varying reaction rate, operation simplicity, need of a fraction of volume and capability of being integrated with other functional elements. The scope of the present work involves the development of a real-time continuous flow microfluidic device, fabricated by 3D printing-governed rapid prototyping method, eventually leading to an automated and robust platform to process multiple DNA samples for detection of MDRTB-associated mutations. The thermal gradient characteristic to the PCR process is produced using peltier units appropriate to the microfluidic environment fully monitored and controlled by a low cost controller driven by a Data Acquisition System. The process efficiency achieved in the microfluidic environment in terms of output per cycle is expected to be on par with the traditional PCR and capable of earning the additional advantages of being faster and minimizing the handling.

  2. Evaluation of commercial kit based on loop-mediated isothermal amplification for rapid detection of low levels of uninjured and injured Salmonella on duck meat, bean sprouts, and fishballs in Singapore.

    PubMed

    Lim, Hazel Sin Yue; Zheng, Qianwang; Miks-Krajnik, Marta; Turner, Matthew; Yuk, Hyun-Gyun

    2015-06-01

    The objective of this study was to evaluate performance of the commercial kit based on loop-mediated isothermal amplification (LAMP) in comparison with the International Organization for Standardization method for detecting uninjured and sublethally injured Salmonella cells artificially inoculated at levels of 10(0) and 10(1) CFU/25 g on raw duck wing, raw mung bean sprouts, and processed fishballs. Injured cells were prepared by a heat treatment for duck wings and fishball samples and a chlorine treatment for bean sprout samples. Additionally, a validation study was performed on naturally contaminated food samples sold in Singapore. A total of 110 samples of each commodity were analyzed in this study. Regardless of inoculum levels, the detection by the commercial LAMP kit showed 100% sensitivity and specificity for both inoculated and uninoculated samples compared with the International Organization for Standardization method, with the exception of bean sprout samples. Only 20% of bean sprout samples inoculated with 10(0) CFU/25 g injured Salmonella cells were positive by using the commercial LAMP-based kit. However, all negative samples became positive following a secondary enrichment in Rappaport-Vassiliadis medium with soy broth or after concentration by centrifugation. These results suggest that secondary enrichment or centrifugation should be considered as an additional step to increase the sensitivity of the commercial LAMP-based kit with low numbers of injured target cells in samples with high background microflora (such as mung bean sprouts). The validation study also showed that the commercial LAMP-based kit provided 91% sensitivity and 95% specificity for naturally contaminated samples. Thus, this study demonstrates that the commercial LAMP-based kit might be a cost-effective method, as this system could provide rapid, accurate detection of both uninjured and injured Salmonella cells on raw duck wings, raw mung bean sprouts, and processed fishballs in less than 26 h.

  3. Rapid Detection of Ebola Virus with a Reagent-Free, Point-of-Care Biosensor

    PubMed Central

    Baca, Justin T.; Severns, Virginia; Lovato, Debbie; Branch, Darren W.; Larson, Richard S.

    2015-01-01

    Surface acoustic wave (SAW) sensors can rapidly detect Ebola antigens at the point-of-care without the need for added reagents, sample processing, or specialized personnel. This preliminary study demonstrates SAW biosensor detection of the Ebola virus in a concentration-dependent manner. The detection limit with this methodology is below the average level of viremia detected on the first day of symptoms by PCR. We observe a log-linear sensor response for highly fragmented Ebola viral particles, with a detection limit corresponding to 1.9 × 104 PFU/mL prior to virus inactivation. We predict greatly improved sensitivity for intact, infectious Ebola virus. This point-of-care methodology has the potential to detect Ebola viremia prior to symptom onset, greatly enabling infection control and rapid treatment. This biosensor platform is powered by disposable AA batteries and can be rapidly adapted to detect other emerging diseases in austere conditions. PMID:25875186

  4. Micromotors to capture and destroy anthrax simulant spores.

    PubMed

    Orozco, Jahir; Pan, Guoqing; Sattayasamitsathit, Sirilak; Galarnyk, Michael; Wang, Joseph

    2015-03-07

    Towards addressing the need for detecting and eliminating biothreats, we describe a micromotor-based approach for screening, capturing, isolating and destroying anthrax simulant spores in a simple and rapid manner with minimal sample processing. The B. globilli antibody-functionalized micromotors can recognize, capture and transport B. globigii spores in environmental matrices, while showing non-interactions with excess of non-target bacteria. Efficient destruction of the anthrax simulant spores is demonstrated via the micromotor-induced mixing of a mild oxidizing solution. The new micromotor-based approach paves a way to dynamic multifunctional systems that rapidly recognize, isolate, capture and destroy biological threats.

  5. AE Monitoring of Diamond Turned Rapidly Soldified Aluminium 443

    NASA Astrophysics Data System (ADS)

    Onwuka, G.; Abou-El-Hossein, K.; Mkoko, Z.

    2017-05-01

    The fast replacement of conventional aluminium with rapidly solidified aluminium alloys has become a noticeable trend in the current manufacturing industries involved in the production of optics and optical molding inserts. This is as a result of the improved performance and durability of rapidly solidified aluminium alloys when compared to conventional aluminium. Melt spinning process is vital for manufacturing rapidly solidified aluminium alloys like RSA 905, RSA 6061 and RSA 443 which are common in the industries today. RSA 443 is a newly developed alloy with few research findings and huge research potential. There is no available literature focused on monitoring the machining of RSA 443 alloys. In this research, Acoustic Emission sensing technique was applied to monitor the single point diamond turning of RSA 443 on an ultrahigh precision lathe machine. The machining process was carried out after careful selection of feed, speed and depths of cut. The monitoring process was achieved with a high sampling data acquisition system using different tools while concurrent measurement of the surface roughness and tool wear were initiated after covering a total feed distance of 13km. An increasing trend of raw AE spikes and peak to peak signal were observed with an increase in the surface roughness and tool wear values. Hence, acoustic emission sensing technique proves to be an effective monitoring method for the machining of RSA 443 alloy.

  6. Ultrasonic Micro-Blades for the Rapid Extraction of Impact Tracks from Aerogel

    NASA Technical Reports Server (NTRS)

    Ishii, H. A.; Graham, G. A.; Kearsley, A. T.; Grant, P. G.; Snead, C. J.; Bradley, J. P.

    2005-01-01

    The science return of NASA's Stardust Mission with its valuable cargo of cometary debris hinges on the ability to efficiently extract particles from silica aerogel collectors. The current method for extracting cosmic dust impact tracks is a mature procedure involving sequential perforation of the aerogel with glass needles on computer controlled micromanipulators. This method is highly successful at removing well-defined aerogel fragments of reasonable optical clarity while causing minimal damage to the surrounding aerogel collector tile. Such a system will be adopted by the JSC Astromaterials Curation Facility in anticipation of Stardust s arrival in early 2006. In addition to Stardust, aerogel is a possible collector for future sample return missions and is used for capture of hypervelocity ejecta in high power laser experiments of interest to LLNL. Researchers will be eager to obtain Stardust samples for study as quickly as possible, and rapid extraction tools requiring little construction, training, or investment would be an attractive asset. To this end, we have experimented with micro-blades for the Stardust impact track extraction process. Our ultimate goal is a rapid extraction system in a clean electron beam environment, such as an SEM or dual-beam FIB, for in situ sample preparation, mounting and analysis.

  7. Rapid colorimetric assay for detection of Listeria monocytogenes in food samples using LAMP formation of DNA concatemers and gold nanoparticle-DNA probe complex

    NASA Astrophysics Data System (ADS)

    Wachiralurpan, Sirirat; Sriyapai, Thayat; Areekit, Supatra; Sriyapai, Pichapak; Augkarawaritsawong, Suphitcha; Santiwatanakul, Somchai; Chansiri, Kosum

    2018-04-01

    ABSTRACT Listeria monocytogenes is a major foodborne pathogen of global health concern. Herein, the rapid diagnosis of L. monocytogenes has been achieved using loop-mediated isothermal amplification (LAMP) based on the phosphatidylcholine-phospholipase C gene (plcB). Colorimetric detection was then performed through the formation of DNA concatemers and a gold nanoparticle/DNA probe complex (GNP/DNA probe). The overall detection process was accomplished within approximately 1 h with no need for complicated equipment. The limits of detection for L. monocytogenes in the forms of purified genomic DNA and pure culture were 800 fg and 2.82 CFU mL-1, respectively. No cross reactions were observed from closely related bacteria species. The LAMP-GNP/DNA probe assay was applied to the detection of 200 raw chicken meat samples and compared to routine standard methods. The data revealed that the specificity, sensitivity and accuracy were 100%, 90.20% and 97.50%, respectively. The present assay was 100% in conformity with LAMP-agarose gel electrophoresis assay. Five samples that were negative by both assays appeared to have the pathogen at below the level of detection. The assay can be applied as a rapid direct screening method for L. monocytogenes.

  8. Determining the physical processes behind four large eruptions in rapid sequence in the San Juan caldera cluster (Colorado, USA)

    NASA Astrophysics Data System (ADS)

    Curry, Adam; Caricchi, Luca; Lipman, Peter

    2017-04-01

    Large, explosive volcanic eruptions can have both immediate and long-term negative effects on human societies. Statistical analyses of volcanic eruptions show that the frequency of the largest eruptions on Earth (> ˜450 km3) differs from that observed for smaller eruptions, suggesting different physical processes leading to eruption. This project will characterize the petrography, whole-rock geochemistry, mineral chemistry, and zircon geochronology of four caldera-forming ignimbrites from the San Juan caldera cluster, Colorado, to determine the physical processes leading to eruption. We collected outflow samples along stratigraphy of the three caldera-forming ignimbrites of the San Luis caldera complex: the Nelson Mountain Tuff (>500 km3), Cebolla Creek Tuff (˜250 km3), and Rat Creek Tuff (˜150 km3); and we collected samples of both outflow and intracaldera facies of the Snowshoe Mountain Tuff (>500 km3), which formed the Creede caldera. Single-crystal sanidine 40Ar/39Ar ages show that these eruptions occurred in rapid succession between 26.91 ± 0.02 Ma (Rat Creek) and 26.87 ± 0.02 Ma (Snowshoe Mountain), providing a unique opportunity to investigate the physical processes leading to a rapid sequence of large, explosive volcanic eruptions. Recent studies show that the average flux of magma is an important parameter in determining the frequency and magnitude of volcanic eruptions. High-precision isotope-dilution thermal ionization mass spectrometry (ID-TIMS) zircon geochronology will be performed to determine magma fluxes, and cross-correlation of chemical profiles in minerals will be performed to determine the periodicity of magma recharge that preceded these eruptions. Our project intends to combine these findings with similar data from other volcanic regions around the world to identify physical processes controlling the regional and global frequency-magnitude relationships of volcanic eruptions.

  9. Optimization of Analytical Conditions for a Rapid Determination of Aniline in Environmental Water by Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Furukawa, Koji; Hashimoto, Makoto; Kaneco, Satoshi

    2017-01-01

    A rapid determination of aniline in environmental water was examined based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Environmental water samples were diluted 20-fold with Mill-Q water and measured by LC/MS/MS after adding a surrogate substance (aniline-d 5 ). In the results of the present study, the calibration curve of aniline showed good linearity in the range of 0.05 - 2.0 μg/L. Since the RSD (repeatability) by measuring repeatedly an aniline standard solution (0.05 μg/L, n = 7) was 3.2%, the repeatability of this work was very excellent. In addition, the recovery rate of aniline in environmental water was in the range of 99.0 - 102% with RSD 3.4 - 7.7%, and very good recovery test results were obtained. From these results, this analytical method was confirmed to be effective for aniline measurements of environmental water samples. Also, it is possible to conduct rapid analyses of aniline in environmental water without any solid-phase extraction process, compared to the solid-phase extraction-GC/MS method.

  10. Preparation and performance study of MgFe2O4/metal-organic framework composite for rapid removal of organic dyes from water

    NASA Astrophysics Data System (ADS)

    Tian, Huairu; Peng, Jun; Lv, Tingting; Sun, Chen; He, Hua

    2018-01-01

    In present study, a stable and magnetic metal-organic framework (MOF) material was synthesized by simple solvothermal method as adsorbent to rapid removal of two organic dyes, the Rhodamine B (RB) and Rhodamine 6G (Rh6G), in water samples. The prepared material showed great characteristics of large surface area (519.86 m2 g-1), excellent magnetic responsivity (35.00 emu g-1) and rapid removal (within 5 min). Maximum adsorption capacities of the magnetic material toward RB and Rh6G were up to 219.78 and 306.75 mg g-1, respectively. Adsorption kinetics suggested the adsorption process met the pseudo-second-order kinetic model. The prepared material could be reused at least 10 times by washing with acetonitrile solution, the relative standard deviation (RSD) of these ten cycles removal efficiency was 4.8%. In conclusion, good chemical inertness, a mechanical/water stability and super-hydrophilicity feature made this MOF a promising adsorbent for targets removal from environmental water sample.

  11. Determination of polychlorinated biphenyls in milk samples by saponification-solid-phase microextraction.

    PubMed

    Llompart, M; Pazos, M; Landin, P; Cela, R

    2001-12-15

    A saponification-HSSPME procedure has been developed for the extraction of PCBs from milk samples. Saponification of the samples improves the PCB extraction efficiency and allows attaining lower background. A mixed-level fractional design has been used to optimize the sample preparation process. Five variables have been considered: extraction time, agitation, kind of microextraction fiber, concentration, and volume of NaOH aqueous solution. Also the kinetic of the process has been studied with the two fibers (100-microm PDMS and 65-microm PDMS-DVB) included in this study. Analyses were performed on a gas chromatograph equipped with an electron capture detector and a gas chromatograph coupled to a mass selective detector working in MS-MS mode. The proposed method is simple and rapid, and yields high sensitivity, with detection limits below 1 ng/mL, good linearity, and reproducibility. The method has been applied to liquid milk samples with different fat content covering the whole commercial range, and it has been validated with powdered milk certified reference material.

  12. Miniaturized Sample Preparation and Rapid Detection of Arsenite in Contaminated Soil Using a Smartphone.

    PubMed

    Siddiqui, Mohd Farhan; Kim, Soocheol; Jeon, Hyoil; Kim, Taeho; Joo, Chulmin; Park, Seungkyung

    2018-03-04

    Conventional methods for analyzing heavy metal contamination in soil and water generally require laboratory equipped instruments, complex procedures, skilled personnel and a significant amount of time. With the advancement in computing and multitasking performances, smartphone-based sensors potentially allow the transition of the laboratory-based analytical processes to field applicable, simple methods. In the present work, we demonstrate the novel miniaturized setup for simultaneous sample preparation and smartphone-based optical sensing of arsenic As(III) in the contaminated soil. Colorimetric detection protocol utilizing aptamers, gold nanoparticles and NaCl have been optimized and tested on the PDMS-chip to obtain the high sensitivity with the limit of detection of 0.71 ppm (in the sample) and a correlation coefficient of 0.98. The performance of the device is further demonstrated through the comparative analysis of arsenic-spiked soil samples with standard laboratory method, and a good agreement with a correlation coefficient of 0.9917 and the average difference of 0.37 ppm, are experimentally achieved. With the android application on the device to run the experiment, the whole process from sample preparation to detection is completed within 3 hours without the necessity of skilled personnel. The approximate cost of setup is estimated around 1 USD, weight 55 g. Therefore, the presented method offers the simple, rapid, portable and cost-effective means for onsite sensing of arsenic in soil. Combined with the geometric information inside the smartphones, the system will allow the monitoring of the contamination status of soils in a nation-wide manner.

  13. Rapid Multiplex PCR Assay To Identify Respiratory Viral Pathogens: Moving Forward Diagnosing The Common Cold

    PubMed Central

    Gordon, Sarah M; Elegino-Steffens, Diane U; Agee, Willie; Barnhill, Jason; Hsue, Gunther

    2013-01-01

    Upper respiratory tract infections (URIs) can be a serious burden to the healthcare system. The majority of URIs are viral in etiology, but definitive diagnosis can prove difficult due to frequently overlapping clinical presentations of viral and bacterial infections, and the variable sensitivity, and lengthy turn-around time of viral culture. We tested new automated nested multiplex PCR technology, the FilmArray® system, in the TAMC department of clinical investigations, to determine the feasibility of replacing the standard viral culture with a rapid turn-around system. We conducted a feasibility study using a single-blinded comparison study, comparing PCR results with archived viral culture results from a convenience sample of cryopreserved archived nasopharyngeal swabs from acutely ill ED patients who presented with complaints of URI symptoms. A total of 61 archived samples were processed. Viral culture had previously identified 31 positive specimens from these samples. The automated nested multiplex PCR detected 38 positive samples. In total, PCR was 94.5% concordant with the previously positive viral culture results. However, PCR was only 63.4% concordant with the negative viral culture results, owing to PCR detection of 11 additional viral pathogens not recovered on viral culture. The average time to process a sample was 75 minutes. We determined that an automated nested multiplex PCR is a feasible alternative to viral culture in an acute clinical setting. We were able to detect at least 94.5% as many viral pathogens as viral culture is able to identify, with a faster turn-around time. PMID:24052914

  14. Predictive Detection of Tuberculosis using Electronic Nose Technology

    NASA Astrophysics Data System (ADS)

    Gibson, Tim; Kolk, Arend; Reither, Klaus; Kuipers, Sjoukje; Hallam, Viv; Chandler, Rob; Dutta, Ritaban; Maboko, Leonard; Jung, Jutta; Klatser, Paul

    2009-05-01

    The adaptation and use of a Bloodhound® ST214 electronic nose to rapidly detect TB in sputum samples has been discussed in the past, with some promising results being obtained in 2007. Some of the specific VOC's associated with Mycobacteria tuberculosis organisms are now being discovered and a paper was published in 2008, but the method of predicting the presence of TB in sputum samples using the VOC biomarkers has yet to be fully optimised. Nevertheless, with emphasis on the sampling techniques and with new data processing techniques to obtain consistent results progress is being made Sensitivity and specificity levels for field detection of TB have been set by WHO at a minimum level of 85% and 95% respectively, and the e-nose technique is working towards these figures. In a series of experiments carried out in Mbeya, Tanzania, Africa, data from a full 5 days of sampling was combined giving a total of 248 sputum samples analysed. From the data obtained we can report results that show specificities and sensitivities in the 70-80% region when actually predicting the presence of TB in unknown sputum samples. The results are a further step forward in the rapid detection of TB in the clinics in developing countries and show continued promise for future development of an optimised instrument for TB prediction.

  15. A biosensor platform for rapid detection of E. coli in drinking water.

    PubMed

    Hesari, Nikou; Alum, Absar; Elzein, Mohamad; Abbaszadegan, Morteza

    2016-02-01

    There remains a need for rapid, specific and sensitive assays for the detection of bacterial indicators for water quality monitoring. In this study, a strategy for rapid detection of Escherichia coli in drinking water has been developed. This strategy is based on the use of the substrate 4-methylumbelliferyl-β-d-glucuronide (MUG), which is hydrolyzed rapidly by the action of E. coli β-d-glucuronidase (GUD) enzyme to yield a fluorogenic 4-methylumbelliferone (4-MU) product that can be quantified and related to the number of E. coli cells present in water samples. In this study, the detection time required for the biosensor response ranged between 20 and 120 min, depending on the number of bacteria in the sample. This approach does not need extensive sample processing with a rapid detection capability. The specificity of the MUG substrate was examined in both, pure cultures of non-target bacterial genera such as Klebsiella, Salmonella, Enterobacter and Bacillus. Non-target substrates that included 4-methylumbelliferyl-β-d-galactopyranoside (MUGal) and l-leucine β-naphthylamide aminopeptidase (LLβ-N) were also investigated to identify nonspecific patterns of enzymatic activities in E. coli. GUD activity was found to be specific for E. coli and no further enzymatic activity was detected by other species. In addition, fluorescence assays were performed for the detection of E. coli to generate standard curves; and the sensitivity of the GUD enzymatic response was measured and repeatedly determined to be less than 10 E. coli cells in a reaction vial. The applicability of the method was tested by performing multiple fluorescence assays under pure and mixed bacterial flora in environmental samples. The results of this study showed that the fluorescence signals generated in samples using specific substrate molecules can be utilized to develop a bio-sensing platform for the detection of E. coli in drinking water. Furthermore, this system can be applied independently or in conjunction with other methods as a part of an array of biochemical assays in order to reliably detect E. coli in water. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Report on Initial Direct Soil Leaching Experiments Using Post-Detonation Debris

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gostic, R.; Knight, K. B.; Borg, L.

    2011-08-01

    A key challenge of nuclear forensics is reducing the time and manpower effort required to measure nuclear debris compositions. The overall motivation for this work is to explore development of a robust, automated system that can be used to concurrently analyze several elements/isotopes associated with the forensic signature of nuclear materials. The primary focus of this research has been to methodically investigate if rapid partial leaching of post-detonation debris can yield usable elemental and isotopic information for interpretation. The unique requirements of post-detonation nuclear forensics have not been fully adapted to or fully incorporated contemporary chemical separation techniques. Challenges includemore » addressing the range of material matrices or mixed fission product and actinide compositions and concentrations that might be encountered. These include, but are not limited to, puddle melt glass, urban debris, seawater, air filters, iron-rich urban debris, asphalt, and silica sand. Separation of these elements and their subsequent measurement is a key element of related laboratory analysis activity. Existing practices at LLNL rely on proven but time-consuming and labor intensive processes. Significant time and labor savings are possible in chemical separations, however, if rapid processing methods can be adapted to post-detonation debris. Development of a simple and reliable leaching technique could shorten analytical times and would be useful as a field deployable method for the preliminary characterization of actinide isotopic ratios in soils. Measurement of isotopic ratios in the field using modern mass spectrometry capabilities such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is desirable, taking advantage of the extended range of isotopic systems measureable using such instruments. Sample introduction to these types of mass spectrometry instruments requires partial leaching or full dissolution of a sample to remove isobaric (same mass) interferences, and, in some cases, to concentrate the elements(s) of interest. To develop a field-deployable mass spectrometry capability, therefore, automated and robust leaching of likely debris samples (ranging from silicates and oxides to metals and urban materials such as concrete and asphalt), followed by separation/purification through cation exchange column chemistry is necessary. In a post-detonation environment, analysis of melt glasses via rapid leaching and ICP-MS could be a viable route to the same goal. This report presents initial leaching experiments on ‘uncontaminated’ soils, as well as data from melt glass from a single nuclear weapons test. Samples were characterized by gamma spectrometry, then aliquoted for rapid leaching experiments. Experiments were conducted using two different rapid acid treatments to leach the soils. Following leaching, the leachate solutions were analyzed by ICP-MS to determine if U isotopic composition. We present these data to address the question as to whether or not rapid (~1 hr) leaching techniques have the potential to yield meaningful U isotopic compositions, without the need for a complete (time consuming) sample dissolution and separation.« less

  17. Rapid and sensitive detection of Zika virus by reverse transcription loop-mediated isothermal amplification.

    PubMed

    Wang, Xuan; Yin, Fenggui; Bi, Yuhai; Cheng, Gong; Li, Jing; Hou, Lidan; Li, Yunlong; Yang, Baozhi; Liu, Wenjun; Yang, Limin

    2016-12-01

    Zika virus (ZIKV) is an arbovirus that recently emerged and has expanded worldwide, causing a global threat and raising international concerns. Current molecular diagnostics, e.g., real-time PCR and reverse transcription PCR (RT-PCR), are time consuming, expensive, and can only be deployed in a laboratory instead of for field diagnostics. This study aimed to develop a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) platform showing sensitivity, specificity, and more convenience than previous methods, being easily distributed and implemented. Specific primers were designed and screened to target the entire ZIKV genome. The analytical sensitivity and specificity of the assay were evaluated and compared with traditional PCR and quantitative real-time PCR. Three different simulated clinical sample quick preparation protocols were evaluated to establish a rapid and straightforward treatment procedure for clinical specimens in open field detection. The RT-LAMP assay for detection of ZIKV demonstrated superior specificity and sensitivity compared to traditional PCR at the optimum reaction temperature. For the ZIKV RNA standard, the limit of detection was 20 copies/test. For the simulated ZIKV clinical samples, the limit of detection was 0.02 pfu/test, which was one order of magnitude higher than RT-PCR and similar to real-time PCR. The detection limit of simulated ZIKV specimens prepared using a protease quick processing method was consistent with that of samples prepared using commercial nucleic acid extraction kits, indicating that our ZIKV detection method could be used in point-of-care testing. The RT-LAMP assay had excellent sensitivity and specificity for detecting ZIKV and can be deployed together with a rapid specimen processing method, offering the possibility for ZIKV diagnosis outside of the laboratory. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Field-deployable, quantitative, rapid identification of active Ebola virus infection in unprocessed blood† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7sc03281a

    PubMed Central

    Shah, Kavit; Bentley, Emma; Tyler, Adam; Richards, Kevin S. R.; Wright, Edward; Easterbrook, Linda; Lee, Diane; Cleaver, Claire; Usher, Louise; Burton, Jane E.; Pitman, James K.; Bruce, Christine B.; Edge, David; Lee, Martin; Nazareth, Nelson; Norwood, David A.

    2017-01-01

    The West African Ebola virus outbreak underlined the importance of delivering mass diagnostic capability outside the clinical or primary care setting in effectively containing public health emergencies caused by infectious disease. Yet, to date, there is no solution for reliably deploying at the point of need the gold standard diagnostic method, real time quantitative reverse transcription polymerase chain reaction (RT-qPCR), in a laboratory infrastructure-free manner. In this proof of principle work, we demonstrate direct performance of RT-qPCR on fresh blood using far-red fluorophores to resolve fluorogenic signal inhibition and controlled, rapid freeze/thawing to achieve viral genome extraction in a single reaction chamber assay. The resulting process is entirely free of manual or automated sample pre-processing, requires no microfluidics or magnetic/mechanical sample handling and thus utilizes low cost consumables. This enables a fast, laboratory infrastructure-free, minimal risk and simple standard operating procedure suited to frontline, field use. Developing this novel approach on recombinant bacteriophage and recombinant human immunodeficiency virus (HIV; Lentivirus), we demonstrate clinical utility in symptomatic EBOV patient screening using live, infectious Filoviruses and surrogate patient samples. Moreover, we evidence assay co-linearity independent of viral particle structure that may enable viral load quantification through pre-calibration, with no loss of specificity across an 8 log-linear maximum dynamic range. The resulting quantitative rapid identification (QuRapID) molecular diagnostic platform, openly accessible for assay development, meets the requirements of resource-limited countries and provides a fast response solution for mass public health screening against emerging biosecurity threats. PMID:29163915

  19. Rapid three-dimensional analysis of renal biopsy sections by low vacuum scanning electron microscopy.

    PubMed

    Inaga, Sumire; Kato, Masako; Hirashima, Sayuri; Munemura, Chishio; Okada, Sinichi; Kameie, Toshio; Katsumoto, Tetsuo; Nakane, Hironobu; Tanaka, Keiichi; Hayashi, Kazuhiko; Naguro, Tomonori

    2010-01-01

    Renal biopsy paraffin sections were examined by low vacuum scanning electron microscopy (LVSEM) in the backscattered electron (BSE) mode, a novel method for rapid pathological analysis which allowed detailed and efficient three-dimensional observations of glomeruli. Renal samples that had been already diagnosed by light microscopy (LM) as exhibiting IgA nephropathy, minor glomerular abnormalities, and membranous glomerulonephritis (GN) were rapidly processed in the present study. Unstained paraffin sections of biopsy samples on glass slides were deparaffinized, stained with platinum blue (Pt-blue) or periodic acid silver-methenamine (PAM), and directly observed with a LVSEM. Overviews of whole sections and detailed observations of individual glomeruli were immediately performed at arbitrary magnifications between ×50 to ×18,000. Cut surface views and surface views of glomeruli were demonstrated at the same time. On Pt-blue-stained sections, podocytes, endothelia, mesangium, and glomerular basement membranes (GBMs) could be distinguished due to the different yields of BSE signals, and pathological features were investigated in every sample. The abnormal surface appearances of podocytes with foot processes and the varying thicknesses of GBM were revealed three-dimensionally, features difficult to observe under LM and transmission electron microscopy. PAM-positive GBM alterations in membranous GN were distinctly visualized through overlying cells without cell removal under LVSEM at high magnification. Not only prominent spike formation but also slight protrusions were clearly revealed in the side views of GBM. Crater-like or hole-like structures were shown in the en face views of GBM. Accordingly, LVSEM is expected to provide a novel approach to the pathological diagnosis of human glomerular diseases using conventional renal biopsy sections.

  20. Determination of rhenium in molybdenite by neutron-activation analysis.

    PubMed

    Terada, K; Yoshimura, Y; Osaki, S; Kiba, T

    1967-01-01

    A neutron-activation method is described for the determination of rhenium in molybdenite. Radiochemical separation by a carrier technique was carried out very rapidly by means of successive liquid-liquid extraction processes. The recovery of rhenium, which was determined by a spectrophotometric method, was about 93%. About 10 samples could be analysed within 6 hr in parallel runs.

  1. Comparison of two commercially available rapid detection methods and a conventional culture method to detect naturally occurring salmonellae on broiler carcasses

    USDA-ARS?s Scientific Manuscript database

    Many different screening devices and sampling methods have been used to detect the presence of naturally occurring Salmonella on commercially processed broiler carcasses. The objective of this study was to compare two commercial screening systems (BAX® and Roka®) to a standard cultural procedure use...

  2. Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing†

    PubMed Central

    Jensen, Erik C.; Stockton, Amanda M.; Chiesl, Thomas N.; Kim, Jungkyu; Bera, Abhisek; Mathies, Richard A.

    2013-01-01

    A digitally programmable microfluidic Automaton consisting of a 2-dimensional array of pneumatically actuated microvalves is programmed to perform new multiscale mixing and sample processing operations. Large (µL-scale) volume processing operations are enabled by precise metering of multiple reagents within individual nL-scale valves followed by serial repetitive transfer to programmed locations in the array. A novel process exploiting new combining valve concepts is developed for continuous rapid and complete mixing of reagents in less than 800 ms. Mixing, transfer, storage, and rinsing operations are implemented combinatorially to achieve complex assay automation protocols. The practical utility of this technology is demonstrated by performing automated serial dilution for quantitative analysis as well as the first demonstration of on-chip fluorescent derivatization of biomarker targets (carboxylic acids) for microchip capillary electrophoresis on the Mars Organic Analyzer. A language is developed to describe how unit operations are combined to form a microfluidic program. Finally, this technology is used to develop a novel microfluidic 6-sample processor for combinatorial mixing of large sets (>26 unique combinations) of reagents. The digitally programmable microfluidic Automaton is a versatile programmable sample processor for a wide range of process volumes, for multiple samples, and for different types of analyses. PMID:23172232

  3. Effect of Sodium Nitrite on Toxin Production by Clostridium botulinum in bacon

    PubMed Central

    Christiansen, L. N.; Tompkin, R. B.; Shaparis, A. B.; Kueper, T. V.; Johnston, R. W.; Kautter, D. A.; Kolari, O. J.

    1974-01-01

    Pork bellies were formulated to 0, 30, 60, 120, 170, or 340 μg of nitrite per g of meat and inoculated with Clostridium botulinum via pickle or after processing and slicing. Processed bacon was stored at 7 or 27 C and assayed for nitrite, nitrate, and botulinal toxin at different intervals. Nitrite levels declined during processing and storage. The rate of decrease was more rapid at 27 than at 7 C. Although not added to the system, nitrate was detected in samples during processing and storage at 7 and 27 C. The amount of nitrate found was related to formulated nitrite levels. No toxin was found in samples incubated at 7 C throughout the 84-day test period. At 27 C, via pickle, inoculated samples with low inoculum (210 C. botulinum per g before processing and 52 per g after processing) became toxic if formulated with 120 μg of nitrite per g of meat or less. Toxin was not detected in bacon formulated with 170 or 340 μg of nitrite per g of meat under these same conditions. Toxin was detected at all formulated nitrite levels in bacon inoculated via the pickle with 19,000 C. botulinum per g (4,300 per g after processing) and in samples inoculated after slicing. However, increased levels of formulated nitrite decreased the probability of botulinal toxin formation in bacon inoculated by both methods. PMID:4596753

  4. Effect of sodium nitrite on toxin production by Clostridium botulinum in bacon.

    PubMed

    Christiansen, L N; Tompkin, R B; Shaparis, A B; Kueper, T V; Johnston, R W; Kautter, D A; Kolari, O J

    1974-04-01

    Pork bellies were formulated to 0, 30, 60, 120, 170, or 340 mug of nitrite per g of meat and inoculated with Clostridium botulinum via pickle or after processing and slicing. Processed bacon was stored at 7 or 27 C and assayed for nitrite, nitrate, and botulinal toxin at different intervals. Nitrite levels declined during processing and storage. The rate of decrease was more rapid at 27 than at 7 C. Although not added to the system, nitrate was detected in samples during processing and storage at 7 and 27 C. The amount of nitrate found was related to formulated nitrite levels. No toxin was found in samples incubated at 7 C throughout the 84-day test period. At 27 C, via pickle, inoculated samples with low inoculum (210 C. botulinum per g before processing and 52 per g after processing) became toxic if formulated with 120 mug of nitrite per g of meat or less. Toxin was not detected in bacon formulated with 170 or 340 mug of nitrite per g of meat under these same conditions. Toxin was detected at all formulated nitrite levels in bacon inoculated via the pickle with 19,000 C. botulinum per g (4,300 per g after processing) and in samples inoculated after slicing. However, increased levels of formulated nitrite decreased the probability of botulinal toxin formation in bacon inoculated by both methods.

  5. Underwater microscope for measuring spatial and temporal changes in bed-sediment grain size

    USGS Publications Warehouse

    Rubin, David M.; Chezar, Henry; Harney, Jodi N.; Topping, David J.; Melis, Theodore S.; Sherwood, Christopher R.

    2007-01-01

    For more than a century, studies of sedimentology and sediment transport have measured bed-sediment grain size by collecting samples and transporting them back to the laboratory for grain-size analysis. This process is slow and expensive. Moreover, most sampling systems are not selective enough to sample only the surficial grains that interact with the flow; samples typically include sediment from at least a few centimeters beneath the bed surface. New hardware and software are available for in situ measurement of grain size. The new technology permits rapid measurement of surficial bed sediment. Here we describe several systems we have deployed by boat, by hand, and by tripod in rivers, oceans, and on beaches.

  6. Underwater Microscope for Measuring Spatial and Temporal Changes in Bed-Sediment Grain Size

    USGS Publications Warehouse

    Rubin, David M.; Chezar, Henry; Harney, Jodi N.; Topping, David J.; Melis, Theodore S.; Sherwood, Christopher R.

    2006-01-01

    For more than a century, studies of sedimentology and sediment transport have measured bed-sediment grain size by collecting samples and transporting them back to the lab for grain-size analysis. This process is slow and expensive. Moreover, most sampling systems are not selective enough to sample only the surficial grains that interact with the flow; samples typically include sediment from at least a few centimeters beneath the bed surface. New hardware and software are available for in-situ measurement of grain size. The new technology permits rapid measurement of surficial bed sediment. Here we describe several systems we have deployed by boat, by hand, and by tripod in rivers, oceans, and on beaches.

  7. Graphene-coated polystyrene-divinylbenzene dispersive solid-phase extraction coupled with supercritical fluid chromatography for the rapid determination of 10 allergenic disperse dyes in industrial wastewater samples.

    PubMed

    Lou, Chaoyan; Wu, Can; Zhang, Kai; Guo, Dandan; Jiang, Lei; Lu, Yang; Zhu, Yan

    2018-05-18

    Allergenic disperse dyes are a group of environmental contaminants, which are toxic and mutagenic to human beings. In this work, a method of dispersive solid-phase extraction (d-SPE) using graphene-coated polystyrene-divinylbenzene (G@PS-DVB) microspheres coupled with supercritical fluid chromatography (SFC) was proposed for the rapid determination of 10 allergenic disperse dyes in industrial wastewater samples. G@PS-DVB microspheres were synthesized by coating graphene (G) sheets onto polystyrene-divinylbenzene (PS-DVB) polymers. Such novel sorbents were employed in d-SPE for the purification and concentration of allergenic disperse dyes in wastewater samples prior to the determination by SFC with UV detection. To achieve the maximum extraction efficiency for the target dyes, several parameters influencing d-SPE process such as sorbent dosage, extraction time, desorption conditions were investigated. SFC conditions including stationary phase, modifier composition and percentage, column temperature, backpressure and flow rate were optimized to well separate the allergenic disperse dyes. Under the optimum conditions, satisfactory linear relationship (R ≥ 0.9989) was observed with the concentration of dyes ranging from 0.02 to 10.0 μg/mL. The limits of detection (LOD, S/N = 3) for the ten dyes were in the range of 1.1-15.6 ng/mL. Recoveries for the spiked samples were between 89.1% and 99.7% with relative standard deviations (RSD) lower than 10.5% in all cases. The proposed method is time-saving, green, precise and repeatable for the analysis of the target dyes. Furthermore, the application of G@PS-DVB based d-SPE process can be potentially expanded to isolate and concentrate other aromatic compounds in various matrices and supercritical fluid chromatography methodology featuring rapidity, accuracy and green will be an ideal candidate for the analysis of these compounds. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Rapid and Sensitive Detection of Cardiac Troponin I for Point-of-Care Tests Based on Red Fluorescent Microspheres.

    PubMed

    Cai, Yanxue; Kang, Keren; Li, Qianru; Wang, Yu; He, Xiaowei

    2018-05-07

    A reliable lateral flow immunoassay (LFIA) based on a facile one-step synthesis of single microspheres in combining with immunochromatography technique was developed to establish a new point-of-care test (POCT) for the rapid and early detection of cardiac troponin I (cTnI), a kind of cardiac specific biomarker for acute myocardial infarction (AMI). The double layered microspheres with clear core-shell structures were produced using soap-free emulsion polymerization method with inexpensive compounds (styrene and acrylic acid). The synthetic process was simple, rapid and easy to control due to one-step synthesis without any complicated procedures. The microspheres are nanostructure with high surface area, which have numerous carboxyl groups on the out layer, resulting in high-efficiency coupling between the carrier and antibody via amide bond. Meanwhile, the red fluorescent dye, Nile-red (NR), was wrapped inside the microspheres to improve its stability, as well to reduce the background noise, because of its higher emission wavelength than interference from real plasma samples. The core-shell structures provided different functional areas to separate antibody and dyes, so the immunoassay has highly sensitive, wide working curves in the range of 0⁻40 ng/mL, low limits of detection (LOD) at 0.016 ng/mL, and limits of quantification (LOQ) at 0.087 ng/mL with coefficient of variations (CV) of 10%. This strategy suggested an outstanding platform for LFIA, with good reproducibility and stability to straightforwardly analyze the plasma samples without washing steps, thereby reducing the operating procedures for non-professionals and promoting detection efficiency. The whole detection process can be completed in less than 15 min. This novel immunoassay offers a reliable and favorable analytical result by detecting the real samples, indicating that it holds great potential as a new alternative for biomolecule detection in complex samples, for the early detection of cardiac specific biomarkers.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, Vineet V.; Paxton, Dean M.; Lavender, Curt A.

    Over the past several years Pacific Northwest National Laboratory (PNNL) has been actively involved in supporting the U.S. Department of Energy National Nuclear Security Administration Office of Material Management and Minimization (formerly Global Threat Reduction Initiative). The U.S. High- Power Research Reactor (USHPRR) project is developing alternatives to existing highly enriched uranium alloy fuel to reduce the proliferation threat. One option for a high-density metal fuel is uranium alloyed with 10 wt% molybdenum (U-10Mo). Forming the U-10Mo fuel plates/foils via rolling is an effective technique and is actively being pursued as part of the baseline manufacturing process. The processing ofmore » these fuel plates requires systematic investigation/understanding of the pre- and post-rolling microstructure, end-state mechanical properties, residual stresses, and defects, their effect on the mill during processing, and eventually, their in-reactor performance. In the work documented herein, studies were conducted to determine the effect of cold and hot rolling the as-cast and homogenized U-10Mo on its microstructure and hardness. The samples were homogenized at 900°C for 48 h, then later annealed for several durations and temperatures to investigate the effect on the material’s microstructure and hardness. The rolling of the as-cast plate, both hot and cold, was observed to form a molybdenum-rich and -lean banded structure. The cold rolling was ineffective, and in some cases exacerbated the as-cast defects. The grains elongated along the rolling direction and formed a pancake shape, while the carbides fractured perpendicularly to the rolling direction and left porosity between fractured particles of UC. The subsequent annealing of these samples at sub-eutectoid temperatures led to rapid precipitation of the ' lamellar phase, mainly in the molybdenum-lean regions. Annealing the samples above the eutectoid temperature did not refine the grain size or the banded microstructure. However, annealing the samples led to quick recovery in hardness as evidenced by a drop in Vickers hardness of 20%. Hot rolling was performed at 650 and 800°C. The hot-rolling mill loads (load separation force) were approximately 40 to 50% less than the cold-rolling for the same reduction and thickness. It was observed that hot rolling the samples with 50% or more reduction in thickness were responsible for dynamic recrystallization in the hot-rolled samples and led to grain refinement. Unlike the cold-rolled samples, the hot-rolled samples did not fracture the carbides and appeared to heal the casting defects. The recovery phenomenon was similar to the cold-rolled samples above the eutectoid temperatures, but owing to the refined grain size, the precipitation of the lamellar phase was far more rapid in these samples and the hardness increased more rapidly than in the cold rolled sample when heated below the eutectoid temperature. The data generated from these rolling efforts has been used to make the process modeling efforts more robust and applicable to all USHPRR partner rolling mills. The flow stress for cold rolling the samples was determined to be between 170-190 ksi, with frictional forces between 0.2 and 0.4 for the PNNL mill. The measured roll separation forces and those simulated using finite element methods for hot and cold rolling for the PNNL rolling mill were in good agreement.« less

  10. Old knowledge and new technologies allow rapid development of model organisms

    PubMed Central

    Cook, Charles E.; Chenevert, Janet; Larsson, Tomas A.; Arendt, Detlev; Houliston, Evelyn; Lénárt, Péter

    2016-01-01

    Until recently the set of “model” species used commonly for cell biology was limited to a small number of well-understood organisms, and developing a new model was prohibitively expensive or time-consuming. With the current rapid advances in technology, in particular low-cost high-throughput sequencing, it is now possible to develop molecular resources fairly rapidly. Wider sampling of biological diversity can only accelerate progress in addressing cellular mechanisms and shed light on how they are adapted to varied physiological contexts. Here we illustrate how historical knowledge and new technologies can reveal the potential of nonconventional organisms, and we suggest guidelines for selecting new experimental models. We also present examples of nonstandard marine metazoan model species that have made important contributions to our understanding of biological processes. PMID:26976934

  11. Rapid Assessment of Aircraft Structural Topologies for Multidisciplinary Optimization and Weight Estimation

    NASA Technical Reports Server (NTRS)

    Samareh, Jamshid A.; Sensmeier, mark D.; Stewart, Bret A.

    2006-01-01

    Algorithms for rapid generation of moderate-fidelity structural finite element models of air vehicle structures to allow more accurate weight estimation earlier in the vehicle design process have been developed. Application of these algorithms should help to rapidly assess many structural layouts before the start of the preliminary design phase and eliminate weight penalties imposed when actual structure weights exceed those estimated during conceptual design. By defining the structural topology in a fully parametric manner, the structure can be mapped to arbitrary vehicle configurations being considered during conceptual design optimization. Recent enhancements to this approach include the porting of the algorithms to a platform-independent software language Python, and modifications to specifically consider morphing aircraft-type configurations. Two sample cases which illustrate these recent developments are presented.

  12. Design and research of built-in sample cell with multiple optical reflections

    NASA Astrophysics Data System (ADS)

    Liu, Jianhui; Wang, Shuyao; Lv, Jinwei; Liu, Shuyang; Zhou, Tao; Jia, Xiaodong

    2017-10-01

    In the field of trace gas measurement, with the characteristics of high sensitivity, high selectivity and rapid detection, tunable diode laser absorption spectroscopy (TDLAS) is widely used in industrial process and trace gas pollution monitoring. Herriott cell is a common form of multiple reflections of the sample cell, the structure of the Herriott cell is relatively simple, which be used to application of trace gas absorption spectroscopy. In the pragmatic situation, the gas components are complicated, and the continuous testing process for a long time can lead to different degree of pollution and corrosion for the reflector in the sample cell. If the mirror is not cleaned up in time, it will have a great influence on the detection accuracy. In order to solve this problem in the process of harsh environment detection, this paper presents a design of the built-in sample cell to avoid the contact of gas and the mirror, thereby effectively reducing corrosion pollution. If there is optical pollution, direct replacement of the built-in optical sample cell can easily to be disassembled, and cleaned. The advantage of this design is long optical path, high precision, cost savings and so on.

  13. Development of a Fluorescence-Based Sensor for Rapid Diagnosis of Cyanide Exposure

    PubMed Central

    2015-01-01

    Although commonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes in areas such as mining, electroplating, and synthetic fiber production. The “heavy” use of cyanide in these industries, along with its necessary transportation, increases the possibility of human exposure. Because the onset of cyanide toxicity is fast, a rapid, sensitive, and accurate method for the diagnosis of cyanide exposure is necessary. Therefore, a field sensor for the diagnosis of cyanide exposure was developed based on the reaction of naphthalene dialdehyde, taurine, and cyanide, yielding a fluorescent β-isoindole. An integrated cyanide capture “apparatus”, consisting of sample and cyanide capture chambers, allowed rapid separation of cyanide from blood samples. Rabbit whole blood was added to the sample chamber, acidified, and the HCN gas evolved was actively transferred through a stainless steel channel to the capture chamber containing a basic solution of naphthalene dialdehyde (NDA) and taurine. The overall analysis time (including the addition of the sample) was <3 min, the linear range was 3.13–200 μM, and the limit of detection was 0.78 μM. None of the potential interferents investigated (NaHS, NH4OH, NaSCN, and human serum albumin) produced a signal that could be interpreted as a false positive or a false negative for cyanide exposure. Most importantly, the sensor was 100% accurate in diagnosing cyanide poisoning for acutely exposed rabbits. PMID:24383576

  14. Rapid method to determine actinides and 89/90Sr in limestone and marble samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; ...

    2016-04-12

    A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89/90Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. Lastly, this approach has a sample preparation time for limestone and marble samples of <4 hours.

  15. Research on laser direct metal deposition

    NASA Astrophysics Data System (ADS)

    Zhang, Yongzhong; Shi, Likai

    2003-03-01

    Laser direct deposition of metallic parts is a new manufacturing technology, which combines with computer-aided design, laser cladding and rapid prototyping. Fully dense metallic parts can be directly obtained through melting the coaxially fed powders with a high-power laser in a layer-by-layer manner. The process characteristics, system composition as well as some research and advancement on laser direct deposition are presented here. The microstructure and properties observation of laser direct formed 663 copper alloy, 316L stainless steel and Rene'95 nickel super alloy samples indicate that, the as-deposited microstructure is similar to rapidly solidified materials, with homogenous composition and free of defects. Under certain conditions, directionally solidified microstructure can be obtained. The as-formed mechanical properties are equal to or exceed those for casting and wrought annealed materials. At the same time, some sample parts with complicate shape are presented for technology demonstration. The formed parts show good surface quality and dimensional accuracy.

  16. Rapid analysis of pharmaceutical drugs using LIBS coupled with multivariate analysis.

    PubMed

    Tiwari, P K; Awasthi, S; Kumar, R; Anand, R K; Rai, P K; Rai, A K

    2018-02-01

    Type 2 diabetes drug tablets containing voglibose having dose strengths of 0.2 and 0.3 mg of various brands have been examined, using laser-induced breakdown spectroscopy (LIBS) technique. The statistical methods such as the principal component analysis (PCA) and the partial least square regression analysis (PLSR) have been employed on LIBS spectral data for classifying and developing the calibration models of drug samples. We have developed the ratio-based calibration model applying PLSR in which relative spectral intensity ratios H/C, H/N and O/N are used. Further, the developed model has been employed to predict the relative concentration of element in unknown drug samples. The experiment has been performed in air and argon atmosphere, respectively, and the obtained results have been compared. The present model provides rapid spectroscopic method for drug analysis with high statistical significance for online control and measurement process in a wide variety of pharmaceutical industrial applications.

  17. Clandestine laboratory scene investigation and processing using portable GC/MS

    NASA Astrophysics Data System (ADS)

    Matejczyk, Raymond J.

    1997-02-01

    This presentation describes the use of portable gas chromatography/mass spectrometry for on-scene investigation and processing of clandestine laboratories. Clandestine laboratory investigations present special problems to forensic investigators. These crime scenes contain many chemical hazards that must be detected, identified and collected as evidence. Gas chromatography/mass spectrometry performed on-scene with a rugged, portable unit is capable of analyzing a variety of matrices for drugs and chemicals used in the manufacture of illicit drugs, such as methamphetamine. Technologies used to detect various materials at a scene have particular applications but do not address the wide range of samples, chemicals, matrices and mixtures that exist in clan labs. Typical analyses performed by GC/MS are for the purpose of positively establishing the identity of starting materials, chemicals and end-product collected from clandestine laboratories. Concerns for the public and investigator safety and the environment are also important factors for rapid on-scene data generation. Here is described the implementation of a portable multiple-inlet GC/MS system designed for rapid deployment to a scene to perform forensic investigations of clandestine drug manufacturing laboratories. GC/MS has long been held as the 'gold standard' in performing forensic chemical analyses. With the capability of GC/MS to separate and produce a 'chemical fingerprint' of compounds, it is utilized as an essential technique for detecting and positively identifying chemical evidence. Rapid and conclusive on-scene analysis of evidence will assist the forensic investigators in collecting only pertinent evidence thereby reducing the amount of evidence to be transported, reducing chain of custody concerns, reducing costs and hazards, maintaining sample integrity and speeding the completion of the investigative process.

  18. U.S. Geological Survey silicate rock standards

    USGS Publications Warehouse

    Flanagan, F.J.

    1967-01-01

    The U.S. Geological Survey has processed six silicate rocks to provide new reference samples to supplement G-1 and W-1. Complete conventional, rapid rock, and spectrochemical analyses by the U.S. Geological Survey are reported for a granite (replacement for G-1), a granodiorite, an andesite, a peridotite, a dunite, and a basalt. Analyses of variance for nickel, chromium, copper, and zirconium in each rock sample showed that for these elements, the rocks can be considered homogeneous. Spectrochemical estimates are given for the nickel, chromium, copper, and zirconium contents of the samples. The petrography of five of the six rocks is described and CIPW norms are presented. ?? 1967.

  19. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    PubMed

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of <10 min. This sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  20. Rapid Filtration Separation-Based Sample Preparation Method for Bacillus Spores in Powdery and Environmental Matrices

    PubMed Central

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M.; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T.; Bastien, Martine; Stewart, Gale; Leblanc, Éric; Sato, Sachiko

    2012-01-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of <10 min. This sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation. PMID:22210204

  1. Quality assessment of raw and processed Arctium lappa L. through multicomponent quantification, chromatographic fingerprint, and related chemometric analysis.

    PubMed

    Qin, Kunming; Wang, Bin; Li, Weidong; Cai, Hao; Chen, Danni; Liu, Xiao; Yin, Fangzhou; Cai, Baochang

    2015-05-01

    In traditional Chinese medicine, raw and processed herbs are used to treat different diseases. Suitable quality assessment methods are crucial for the discrimination between raw and processed herbs. The dried fruit of Arctium lappa L. and their processed products are widely used in traditional Chinese medicine, yet their therapeutic effects are different. In this study, a novel strategy using high-performance liquid chromatography and diode array detection coupled with multivariate statistical analysis to rapidly explore raw and processed Arctium lappa L. was proposed and validated. Four main components in a total of 30 batches of raw and processed Fructus Arctii samples were analyzed, and ten characteristic peaks were identified in the fingerprint common pattern. Furthermore, similarity evaluation, principal component analysis, and hierachical cluster analysis were applied to demonstrate the distinction. The results suggested that the relative amounts of the chemical components of raw and processed Fructus Arctii samples are different. This new method has been successfully applied to detect the raw and processed Fructus Arctii in marketed herbal medicinal products. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Recent developments and applications of hyperspectral imaging for rapid detection of mycotoxins and mycotoxigenic fungi in food products.

    PubMed

    Xing, Fuguo; Yao, Haibo; Liu, Yang; Dai, Xiaofeng; Brown, Robert L; Bhatnagar, Deepak

    2017-08-28

    Mycotoxins are the foremost naturally occurring contaminants of food products such as corn, peanuts, tree nuts, and wheat. As the secondary metabolites, mycotoxins are mainly synthesized by many species of the genera Aspergillus, Fusarium and Penicillium, and are considered highly toxic and carcinogenic to humans and animals. Most mycotoxins are detected and quantified by analytical chemistry-based methods. While mycotoxigenic fungi are usually identified and quantified by biological methods. However, these methods are time-consuming, laborious, costly, and inconsistent because of the variability of the grain-sampling process. It is desirable to develop rapid, non-destructive and efficient methods that objectively measure and evaluate mycotoxins and mycotoxigenic fungi in food. In recent years, some spectroscopy-based technologies such as hyperspectral imaging (HSI), Raman spectroscopy, and Fourier transform infrared spectroscopy have been extensively investigated for their potential use as tools for the detection, classification, and sorting of mycotoxins and toxigenic fungal contaminants in food. HSI integrates both spatial and spectral information for every pixel in an image, making it suitable for rapid detection of large quantities of samples and more heterogeneous samples and for in-line sorting in the food industry. In order to track the latest research developments in HSI, this paper gives a brief overview of the theories and fundamentals behind the technology and discusses its applications in the field of rapid detection and sorting of mycotoxins and toxigenic fungi in food products. Additionally, advantages and disadvantages of HSI are compared, and its potential use in commercial applications is reported.

  3. Validation of a rapid bacteria endospore enumeration system for use with spacecraft assembly

    NASA Astrophysics Data System (ADS)

    Chen, F.; Kuhlman, G.; Kirschner, L.; Kazarians, G.; Matsuyama, A.; Pickett, M.; Venkateswaran, K.; Kastner, J.; Kern, R.

    NASA planetary protection policy sets forth strict limits on the number of bacterial endospores that can be present on a spacecraft at launch Currently the only approved method for counting the spores is a culture based assay that requires three days to produce results a timeframe that can be at odds with the rapid pace and rigorous deadlines of spacecraft assembly A possible alternative to the traditional culture based approach is the Millipore Rapid Microbiology Detection System RMDS which has previously been used for process and contamination control in the pharmaceutical and food industries The RMDS is rapid and simple shows high sensitivity 1 colony forming unit CFU sample and correlates well with traditional culture-based methods It combines membrane filtration adenosine triphosphate ATP bioluminescence chemistry and image analysis based on photon detection with a Charge Coupled Device CCD camera In this study we have optimized the assay condition and evaluated the use of the RMDS as a rapid spore detection tool for NASA applications Seven species of Bacillus nine strains that have been repeatedly isolated from clean room environments were assayed In order to select for spores the samples were subjected to a heat shock step before proceeding with the RMDS incubation protocol All strains were detected by the RMDS in sim 5 hours and these assay times were repeatedly demonstrated along with low image background noise The RMDS-based spore detection method is undergoing the final stages of validation and is

  4. A Field Investigation of Bacillus anthracis Contamination of U.S. Department of Agriculture and Other Washington, D.C., Buildings during the Anthrax Attack of October 2001

    PubMed Central

    Higgins, James A.; Cooper, Mary; Schroeder-Tucker, Linda; Black, Scott; Miller, David; Karns, Jeffrey S.; Manthey, Erlynn; Breeze, Roger; Perdue, Michael L.

    2003-01-01

    In response to a bioterrorism attack in the Washington, D.C., area in October 2001, a mobile laboratory (ML) was set up in the city to conduct rapid molecular tests on environmental samples for the presence of Bacillus anthracis spores and to route samples for further culture analysis. The ML contained class I laminar-flow hoods, a portable autoclave, two portable real-time PCR devices (Ruggedized Advanced Pathogen Identification Device [RAPID]), and miscellaneous supplies and equipment to process samples. Envelopes and swab and air samples collected from 30 locations in the metropolitan area once every three days were subjected to visual examination and DNA extraction, followed by real-time PCR using freeze-dried, fluorescent-probe-based reagents. Surface swabs and air samples were also cultured for B. anthracis at the National Veterinary Service Laboratory (NVSL) in Ames, Iowa. From 24 October 2001 to 15 September 2002, 2,092 pieces of mail were examined, 405 real-time PCR assays were performed (comprising 4,639 samples), and at the NVSL 6,275 samples were subjected to over 18,000 platings. None of the PCR assays on DNA extracted from swab and air samples were positive, but viable spores were cultured from surface swabs taken from six locations in the metropolitan area in October, November, and December 2001 and February, March, and May 2002. DNA extracted from these suspected B. anthracis colonies was positive by real-time and conventional PCRs for the lethal factor, pXO1, and for capA and vrr genes; sequence analysis of the latter amplicons indicated >99% homology with the Ames, vollum, B6273-93, C93022281, and W-21 strains of B. anthracis, suggesting they arose from cross-contamination during the attack through the mail. The RAPID-based PCR analysis provided fast confirmation of suspect colonies from an overnight incubation on agar plates. PMID:12514046

  5. Rapid screening and species identification of E. coli, Listeria, and Salmonella by SERS technique

    NASA Astrophysics Data System (ADS)

    Liu, Yongliang; Chao, Kuanglin; Kim, Moon S.; Nou, Xiangwu

    2008-04-01

    Techniques for routine and rapid screening of the presence of foodborne bacteria are needed, and this study reports the feasibility of citrate-reduced silver colloidal SERS for identifying E. coli, Listeria, and Salmonella. Relative standard deviation (RSD) of SERS spectra from silver colloidal suspensions and ratios of P-O SERS peaks from small molecule (K3PO4) were used to assess the reproducibility, stability, and binding effectiveness of citrate-reduced silver colloids over batch and storage process. The results suggested the reproducibility of silver colloids over batch process and also stability and consistent binding effectiveness over 60-day storage period. Notably, although silver colloidal nanoparticles were stable for at least 90 days, their binding effectiveness began to decrease slightly after 60-day storage, with a binding reduction of about 12% at 90th day. Colloidal silver SERS, as demonstrated here, could be an important alternative technique in the rapid and simultaneous screening of the presence of three most outbreak bacteria due to the exclusive biomarkers, label-free and easy sampling attribute.

  6. Laser rapid forming technology of high-performance dense metal components with complex structure

    NASA Astrophysics Data System (ADS)

    Huang, Weidong; Chen, Jing; Li, Yanming; Lin, Xin

    2005-01-01

    Laser rapid forming (LRF) is a new and advanced manufacturing technology that has been developed on the basis of combining high power laser cladding technology with rapid prototyping (RP) to realize net shape forming of high performance dense metal components without dies. Recently we have developed a set of LRF equipment. LRF experiments were carried out on the equipment to investigate the influences of processing parameters on forming characterizations systematically with the cladding powder materials as titanium alloys, superalloys, stainless steel, and copper alloys. The microstructure of laser formed components is made up of columnar grains or columnar dendrites which grow epitaxially from the substrate since the solid components were prepared layer by layer additionally. The result of mechanical testing proved that the mechanical properties of laser formed samples are similar to or even over that of forging and much better than that of casting. It is shown in this paper that LRF technology is providing a new solution for some difficult processing problems in the high tech field of aviation, spaceflight and automobile industries.

  7. Transient Method for Determining Indoor Chemical Concentrations Based on SPME: Model Development and Calibration.

    PubMed

    Cao, Jianping; Xiong, Jianyin; Wang, Lixin; Xu, Ying; Zhang, Yinping

    2016-09-06

    Solid-phase microextraction (SPME) is regarded as a nonexhaustive sampling technique with a smaller extraction volume and a shorter extraction time than traditional sampling techniques and is hence widely used. The SPME sampling process is affected by the convection or diffusion effect along the coating surface, but this factor has seldom been studied. This paper derives an analytical model to characterize SPME sampling for semivolatile organic compounds (SVOCs) as well as for volatile organic compounds (VOCs) by considering the surface mass transfer process. Using this model, the chemical concentrations in a sample matrix can be conveniently calculated. In addition, the model can be used to determine the characteristic parameters (partition coefficient and diffusion coefficient) for typical SPME chemical samplings (SPME calibration). Experiments using SPME samplings of two typical SVOCs, dibutyl phthalate (DBP) in sealed chamber and di(2-ethylhexyl) phthalate (DEHP) in ventilated chamber, were performed to measure the two characteristic parameters. The experimental results demonstrated the effectiveness of the model and calibration method. Experimental data from the literature (VOCs sampled by SPME) were used to further validate the model. This study should prove useful for relatively rapid quantification of concentrations of different chemicals in various circumstances with SPME.

  8. Assessment of Two Different Drinking Water Treatment Plants for the Removal of Free-living Amoebae, Egypt.

    PubMed

    Al-Herrawy, Ahmad Z; Gad, Mahmoud A

    2017-01-01

    The aim of this study was to compare between slow and rapid sand filters for the removal of free-living amoebae during drinking water treatment production. Overall, 48 water samples were collected from two drinking water treatment plants having two different filtration systems (slow and rapid sand filters) and from inlet and outlet of each plant. Water samples were collected from Fayoum Drinking Water and Wastewater Holding Company, Egypt, during the year 2015. They were processed for detection of FLAs using non-nutrient agar (NNA). The isolates of FLAs were microscopically identified to the genus level based on the morphologic criteria and molecularly confirmed by the aid of PCR using genus-specific primers. The percentage of removal for FLAs through different treatment processes reached its highest rate in the station using slow sand filters (83%), while the removal by rapid sand filter system was 71.4%. Statistically, there was no significant difference ( P =0.55) for the removal of FLAs between the two different drinking water treatment systems. Statistically, seasons had no significant effect on the prevalence of FLAs in the two different drinking water treatment plants. Morphological identification of the isolated FLAs showed the presence of 3 genera namely Acanthamoeba , Naegleria , and Vermamoeba ( Hartmannella ) confirmed by PCR. The appearance of FLAs especially pathogenic amoebae in completely treated drinking water may cause potential health threat although there is no statistical difference between the two examined drinking water filtration systems.

  9. Alternatives to current flow cytometry data analysis for clinical and research studies.

    PubMed

    Gondhalekar, Carmen; Rajwa, Bartek; Patsekin, Valery; Ragheb, Kathy; Sturgis, Jennifer; Robinson, J Paul

    2018-02-01

    Flow cytometry has well-established methods for data analysis based on traditional data collection techniques. These techniques typically involved manual insertion of tube samples into an instrument that, historically, could only measure 1-3 colors. The field has since evolved to incorporate new technologies for faster and highly automated sample preparation and data collection. For example, the use of microwell plates on benchtop instruments is now a standard on virtually every new instrument, and so users can easily accumulate multiple data sets quickly. Further, because the user must carefully define the layout of the plate, this information is already defined when considering the analytical process, expanding the opportunities for automated analysis. Advances in multi-parametric data collection, as demonstrated by the development of hyperspectral flow-cytometry, 20-40 color polychromatic flow cytometry, and mass cytometry (CyTOF), are game-changing. As data and assay complexity increase, so too does the complexity of data analysis. Complex data analysis is already a challenge to traditional flow cytometry software. New methods for reviewing large and complex data sets can provide rapid insight into processes difficult to define without more advanced analytical tools. In settings such as clinical labs where rapid and accurate data analysis is a priority, rapid, efficient and intuitive software is needed. This paper outlines opportunities for analysis of complex data sets using examples of multiplexed bead-based assays, drug screens and cell cycle analysis - any of which could become integrated into the clinical environment. Copyright © 2017. Published by Elsevier Inc.

  10. Using pyrosequencing to shed light on deep mine microbial ecology

    PubMed Central

    Edwards, Robert A; Rodriguez-Brito, Beltran; Wegley, Linda; Haynes, Matthew; Breitbart, Mya; Peterson, Dean M; Saar, Martin O; Alexander, Scott; Alexander, E Calvin; Rohwer, Forest

    2006-01-01

    Background Contrasting biological, chemical and hydrogeological analyses highlights the fundamental processes that shape different environments. Generating and interpreting the biological sequence data was a costly and time-consuming process in defining an environment. Here we have used pyrosequencing, a rapid and relatively inexpensive sequencing technology, to generate environmental genome sequences from two sites in the Soudan Mine, Minnesota, USA. These sites were adjacent to each other, but differed significantly in chemistry and hydrogeology. Results Comparisons of the microbes and the subsystems identified in the two samples highlighted important differences in metabolic potential in each environment. The microbes were performing distinct biochemistry on the available substrates, and subsystems such as carbon utilization, iron acquisition mechanisms, nitrogen assimilation, and respiratory pathways separated the two communities. Although the correlation between much of the microbial metabolism occurring and the geochemical conditions from which the samples were isolated could be explained, the reason for the presence of many pathways in these environments remains to be determined. Despite being physically close, these two communities were markedly different from each other. In addition, the communities were also completely different from other microbial communities sequenced to date. Conclusion We anticipate that pyrosequencing will be widely used to sequence environmental samples because of the speed, cost, and technical advantages. Furthermore, subsystem comparisons rapidly identify the important metabolisms employed by the microbes in different environments. PMID:16549033

  11. Use of Chironomidae (Diptera) Surface-Floating Pupal Exuviae as a Rapid Bioassessment Protocol for Water Bodies

    PubMed Central

    Kranzfelder, Petra; Anderson, Alyssa M.; Egan, Alexander T.; Mazack, Jane E.; Bouchard,, R. William; Rufer, Moriya M.; Ferrington,, Leonard C.

    2015-01-01

    Rapid bioassessment protocols using benthic macroinvertebrate assemblages have been successfully used to assess human impacts on water quality. Unfortunately, traditional benthic larval sampling methods, such as the dip-net, can be time-consuming and expensive. An alternative protocol involves collection of Chironomidae surface-floating pupal exuviae (SFPE). Chironomidae is a species-rich family of flies (Diptera) whose immature stages typically occur in aquatic habitats. Adult chironomids emerge from the water, leaving their pupal skins, or exuviae, floating on the water’s surface. Exuviae often accumulate along banks or behind obstructions by action of the wind or water current, where they can be collected to assess chironomid diversity and richness. Chironomids can be used as important biological indicators, since some species are more tolerant to pollution than others. Therefore, the relative abundance and species composition of collected SFPE reflect changes in water quality. Here, methods associated with field collection, laboratory processing, slide mounting, and identification of chironomid SFPE are described in detail. Advantages of the SFPE method include minimal disturbance at a sampling area, efficient and economical sample collection and laboratory processing, ease of identification, applicability in nearly all aquatic environments, and a potentially more sensitive measure of ecosystem stress. Limitations include the inability to determine larval microhabitat use and inability to identify pupal exuviae to species if they have not been associated with adult males. PMID:26274889

  12. Use of Chironomidae (Diptera) Surface-Floating Pupal Exuviae as a Rapid Bioassessment Protocol for Water Bodies.

    PubMed

    Kranzfelder, Petra; Anderson, Alyssa M; Egan, Alexander T; Mazack, Jane E; Bouchard, R William; Rufer, Moriya M; Ferrington, Leonard C

    2015-07-24

    Rapid bioassessment protocols using benthic macroinvertebrate assemblages have been successfully used to assess human impacts on water quality. Unfortunately, traditional benthic larval sampling methods, such as the dip-net, can be time-consuming and expensive. An alternative protocol involves collection of Chironomidae surface-floating pupal exuviae (SFPE). Chironomidae is a species-rich family of flies (Diptera) whose immature stages typically occur in aquatic habitats. Adult chironomids emerge from the water, leaving their pupal skins, or exuviae, floating on the water's surface. Exuviae often accumulate along banks or behind obstructions by action of the wind or water current, where they can be collected to assess chironomid diversity and richness. Chironomids can be used as important biological indicators, since some species are more tolerant to pollution than others. Therefore, the relative abundance and species composition of collected SFPE reflect changes in water quality. Here, methods associated with field collection, laboratory processing, slide mounting, and identification of chironomid SFPE are described in detail. Advantages of the SFPE method include minimal disturbance at a sampling area, efficient and economical sample collection and laboratory processing, ease of identification, applicability in nearly all aquatic environments, and a potentially more sensitive measure of ecosystem stress. Limitations include the inability to determine larval microhabitat use and inability to identify pupal exuviae to species if they have not been associated with adult males.

  13. Processing of Mn-Al nanostructured magnets by spark plasma sintering and subsequent rapid thermal annealing

    NASA Astrophysics Data System (ADS)

    Saravanan, P.; Vinod, V. T. P.; Černík, Miroslav; Selvapriya, A.; Chakravarty, Dibyendu; Kamat, S. V.

    2015-01-01

    The potential of spark plasma sintering (SPS) in combination with rapid thermal annealing (RTA) for the processing of Mn-Al nanostructured magnets is explored in this study. Ferromagnetic α-Mn alloy powders were processed by high-energy ball milling using Mn (56 at%) and Al (44 at%) as constituent metal elements. The alloying action between Mn and Al due to intensive milling was studied by X-ray diffraction and field-emission scanning electron microscope; while the phase transformation kinetics was investigated using differential scanning calorimetry. The evolution of ferromagnetic properties in the as-milled powders was studied by superconducting quantum interference device (SQUID). Among the Mn-Al alloy powders collected at various milling intervals, the 25 h milled Mn-Al powders showed a good combination of coercivity, Hc (11.3 kA/m) and saturation magnetization, Ms (5.0 A/m2/kg); accordingly, these powders were chosen for SPS. The SPS experiments were conducted at different temperatures: 773, 873 and 973 K and its effect on the density, phase composition and magnetic properties of the Mn-Al bulk samples were investigated. Upon increasing the SPS temperature from 773 to 973 K, the bulk density was found to increase from 3.6 to 4.0 g/cm3. The occurrence of equilibrium β-phase with significant amount of γ2-phase was obvious at all the SPS temperatures; however, crystallization of some amount of τ-phase was evident at 973 K. Irrespective of the SPS temperatures, all the samples demonstrated soft magnetic behavior with Hc and Ms values similar to those obtained for the 25 h milled powders. The magnetic properties of the SPSed samples were significantly improved upon subjecting them to RTA at 1100 K. Through the RTA process, Hc values of 75, 174 and 194 kA/m and Ms values of 19, 21 and 28 A/m2/kg were achieved for the samples SPSed at 773, 873 and 973 K, respectively. The possible reasons for the observed improvement in the magnetic properties of the SPSed samples due to RTA in correlation with their phase composition and microstructure were analyzed and discussed.

  14. Clinician Beliefs and Practices in Dementia Care: Implications for Health Educators

    ERIC Educational Resources Information Center

    Meuser, Thomas M.; Boise, Linda; Morris, John C.

    2004-01-01

    Research on assessment and treatment of Alzheimer's disease (AD) is moving at a rapid pace. Continuing education (CE) providers must translate new findings for clinicians so as to enhance patient care. A two-page survey was distributed by mail to a sample of 5,000 licensed Missouri clinicians to gather data in support of this translation process.…

  15. Current Trends in Ubiquitous Biosensing

    DTIC Science & Technology

    2013-08-01

    fundamental advances have been made in the synergistic combination of research in the fields of microfluidics and optics, coined “optofluidics” [24-26...microfabrication and clean-room techniques for the development of microfluidic devices [27]. Advances in the rapid fabrication of nano- and microfluidic ...Transduction Microfluidic Processing Sample Introduction Optofluidics Enabled Bio-Sensing A B C Figure 4: (A) Schematic diagram of optofluidic tomography

  16. Microfluidic systems and methods of transport and lysis of cells and analysis of cell lysate

    DOEpatents

    Culbertson, Christopher T.; Jacobson, Stephen C.; McClain, Maxine A.; Ramsey, J. Michael

    2004-08-31

    Microfluidic systems and methods are disclosed which are adapted to transport and lyse cellular components of a test sample for analysis. The disclosed microfluidic systems and methods, which employ an electric field to rupture the cell membrane, cause unusually rapid lysis, thereby minimizing continued cellular activity and resulting in greater accuracy of analysis of cell processes.

  17. Microfluidic systems and methods for transport and lysis of cells and analysis of cell lysate

    DOEpatents

    Culbertson, Christopher T [Oak Ridge, TN; Jacobson, Stephen C [Knoxville, TN; McClain, Maxine A [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-02

    Microfluidic systems and methods are disclosed which are adapted to transport and lyse cellular components of a test sample for analysis. The disclosed microfluidic systems and methods, which employ an electric field to rupture the cell membrane, cause unusually rapid lysis, thereby minimizing continued cellular activity and resulting in greater accuracy of analysis of cell processes.

  18. Context-dependent decision-making: a simple Bayesian model

    PubMed Central

    Lloyd, Kevin; Leslie, David S.

    2013-01-01

    Many phenomena in animal learning can be explained by a context-learning process whereby an animal learns about different patterns of relationship between environmental variables. Differentiating between such environmental regimes or ‘contexts’ allows an animal to rapidly adapt its behaviour when context changes occur. The current work views animals as making sequential inferences about current context identity in a world assumed to be relatively stable but also capable of rapid switches to previously observed or entirely new contexts. We describe a novel decision-making model in which contexts are assumed to follow a Chinese restaurant process with inertia and full Bayesian inference is approximated by a sequential-sampling scheme in which only a single hypothesis about current context is maintained. Actions are selected via Thompson sampling, allowing uncertainty in parameters to drive exploration in a straightforward manner. The model is tested on simple two-alternative choice problems with switching reinforcement schedules and the results compared with rat behavioural data from a number of T-maze studies. The model successfully replicates a number of important behavioural effects: spontaneous recovery, the effect of partial reinforcement on extinction and reversal, the overtraining reversal effect, and serial reversal-learning effects. PMID:23427101

  19. Context-dependent decision-making: a simple Bayesian model.

    PubMed

    Lloyd, Kevin; Leslie, David S

    2013-05-06

    Many phenomena in animal learning can be explained by a context-learning process whereby an animal learns about different patterns of relationship between environmental variables. Differentiating between such environmental regimes or 'contexts' allows an animal to rapidly adapt its behaviour when context changes occur. The current work views animals as making sequential inferences about current context identity in a world assumed to be relatively stable but also capable of rapid switches to previously observed or entirely new contexts. We describe a novel decision-making model in which contexts are assumed to follow a Chinese restaurant process with inertia and full Bayesian inference is approximated by a sequential-sampling scheme in which only a single hypothesis about current context is maintained. Actions are selected via Thompson sampling, allowing uncertainty in parameters to drive exploration in a straightforward manner. The model is tested on simple two-alternative choice problems with switching reinforcement schedules and the results compared with rat behavioural data from a number of T-maze studies. The model successfully replicates a number of important behavioural effects: spontaneous recovery, the effect of partial reinforcement on extinction and reversal, the overtraining reversal effect, and serial reversal-learning effects.

  20. A simple and rapid infrared-assisted self enzymolysis extraction method for total flavonoid aglycones extraction from Scutellariae Radix and mechanism exploration.

    PubMed

    Wang, Liping; Duan, Haotian; Jiang, Jiebing; Long, Jiakun; Yu, Yingjia; Chen, Guiliang; Duan, Gengli

    2017-09-01

    A new, simple, and fast infrared-assisted self enzymolysis extraction (IRASEE) approach for the extraction of total flavonoid aglycones (TFA) mainly including baicalein, wogonin, and oroxylin A from Scutellariae Radix is presented to enhance extraction yield. Extraction enzymolysis temperature, enzymolysis liquid-to-solid ratio, enzymolysis pH, enzymolysis time and infrared power, the factors affecting IRASEE procedure, were investigated in a newly designed, temperature-controlled infrared-assisted extraction (TC-IRAE) system to acquire the optimum analysis conditions. The results illustrated that IRASEE possessed great advantages in terms of efficiency and time compared with other conventional extraction techniques. Furthermore, the mechanism of IRASEE was preliminarily explored by observing the microscopic change of the samples surface structures, studying the main chemical compositions change of the samples before and after extraction and investigating the kinetics and thermodynamics at three temperature levels during the IRASEE process. These findings revealed that IRASEE can destroy the surface microstructures to accelerate the mass transfer and reduce the activation energy to intensify the chemical process. This integrative study presents a simple, rapid, efficient, and environmental IRASEE method for TFA extraction which has promising prospects for other similar herbal medicines. Graphical Abstract ᅟ.

  1. Decomposition of algal lipids in clay-enriched marine sediment under oxic and anoxic conditions

    NASA Astrophysics Data System (ADS)

    Lü, Dongwei; Song, Qian; Wang, Xuchen

    2010-01-01

    A series of laboratory incubation experiments were conducted to examine the decomposition of algal organic matter in clay-enriched marine sediment under oxic and anoxic conditions. During the 245-day incubation period, changes in the concentrations of TOC, major algal fatty acid components (14:0, 16:0, 16:1, 18:1 and 20:5), and n-alkanes (C16-C23) were quantified in the samples. Our results indicate that the organic matters were degraded more rapidly in oxic than anoxic conditions. Adsorption of fatty acids onto clay minerals was a rapid and reversible process. Using a simple G model, we calculated the decomposition rate constants for TOC, n-alkanes and fatty acids which ranged from 0.017-0.024 d-1, 0.049-0.103 d-1 and 0.011 to 0.069 d-1, respectively. Algal organic matter degraded in two stages characterized by a fast and a slow degradation processes. The addition of clay minerals montmorillonite and kaolinite to the sediments showed significant influence affecting the decomposition processes of algal TOC and fatty acids by adsorption and incorporation of the compounds with clay particles. Adsorption/association of fatty acids by clay minerals was rapid but appeared to be a slow reversible process. In addition to the sediment redox and clay influence, the structure of the compounds also played important roles in affecting their degradation dynamic in sediments.

  2. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  3. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  4. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    NASA Astrophysics Data System (ADS)

    Freifeld, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-10-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  5. Probing polymer crystallization at processing-relevant cooling rates with synchrotron radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavallo, Dario, E-mail: Dario.cavallo@unige.it; Portale, Giuseppe; Androsch, René

    2015-12-17

    Processing of polymeric materials to produce any kind of goods, from films to complex objects, involves application of flow fields on the polymer melt, accompanied or followed by its rapid cooling. Typically, polymers solidify at cooling rates which span over a wide range, from a few to hundreds of °C/s. A novel method to probe polymer crystallization at processing-relevant cooling rates is proposed. Using a custom-built quenching device, thin polymer films are ballistically cooled from the melt at rates between approximately 10 and 200 °C/s. Thanks to highly brilliant synchrotron radiation and to state-of-the-art X-ray detectors, the crystallization process ismore » followed in real-time, recording about 20 wide angle X-ray diffraction patterns per second while monitoring the instantaneous sample temperature. The method is applied to a series of industrially relevant polymers, such as isotactic polypropylene, its copolymers and virgin and nucleated polyamide-6. Their crystallization behaviour during rapid cooling is discussed, with particular attention to the occurrence of polymorphism, which deeply impact material’s properties.« less

  6. Is rapid automatized naming related to reading and mathematics for the same reason(s)? A follow-up study from kindergarten to Grade 1.

    PubMed

    Georgiou, George K; Tziraki, Niki; Manolitsis, George; Fella, Argyro

    2013-07-01

    We examined (a) what rapid automatized naming (RAN) components (articulation time and/or pause time) predict reading and mathematics ability and (b) what processing skills involved in RAN (speed of processing, response inhibition, working memory, and/or phonological awareness) may explain its relationship with reading and mathematics. A sample of 72 children were followed from the beginning of kindergarten until the end of Grade 1 and were assessed on measures of RAN, general cognitive ability, speed of processing, attention, working memory, phonological awareness, reading, and mathematics. The results indicated that pause time was the critical component in both the RAN-reading and RAN-mathematics relationships and that it shared most of its predictive variance in reading and mathematics with speed of processing and working memory. Our findings further suggested that, unlike the relationship between RAN and reading fluency in Grade 1, there is nothing in the RAN task that is uniquely related to math. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Microstructure investigation of 13Cr-2Mo ODS steel components obtained by high voltage electric discharge compaction technique

    DOE PAGES

    Bogachev, Igor; Yudin, Artem; Grigoryev, Evgeniy; ...

    2015-11-02

    Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10–15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining themore » initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. As a result, the choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.« less

  8. Microstructure Investigation of 13Cr-2Mo ODS Steel Components Obtained by High Voltage Electric Discharge Compaction Technique.

    PubMed

    Bogachev, Igor; Yudin, Artem; Grigoryev, Evgeniy; Chernov, Ivan; Staltsov, Maxim; Khasanov, Oleg; Olevsky, Eugene

    2015-11-02

    Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10-15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine the optimal compaction regime. Three different concentrations of yttria were used to identify its effect on the properties of the samples. It is shown that the utilized ultra-rapid consolidation process in combination with high transmitted energy allows obtaining high density compacts, retaining the initial structure with minimal grain growth. The experimental results indicate some heterogeneity of the structure which may occur in the external layers of the tested samples due to various thermal and electromagnetic in-processing effects. The choice of the optimal parameters of the consolidation enables obtaining samples of acceptable quality.

  9. Silk-based blood stabilization for diagnostics.

    PubMed

    Kluge, Jonathan A; Li, Adrian B; Kahn, Brooke T; Michaud, Dominique S; Omenetto, Fiorenzo G; Kaplan, David L

    2016-05-24

    Advanced personalized medical diagnostics depend on the availability of high-quality biological samples. These are typically biofluids, such as blood, saliva, or urine; and their collection and storage is critical to obtain reliable results. Without proper temperature regulation, protein biomarkers in particular can degrade rapidly in blood samples, an effect that ultimately compromises the quality and reliability of laboratory tests. Here, we present the use of silk fibroin as a solid matrix to encapsulate blood analytes, protecting them from thermally induced damage that could be encountered during nonrefrigerated transportation or freeze-thaw cycles. Blood samples are recovered by simple dissolution of the silk matrix in water. This process is demonstrated to be compatible with a number of immunoassays and provides enhanced sample preservation in comparison with traditional air-drying paper approaches. Additional processing can remediate interactions with conformational structures of the silk protein to further enhance blood stabilization and recovery. This approach can provide expanded utility for remote collection of blood and other biospecimens empowering new modalities of temperature-independent remote diagnostics.

  10. Rapid analyses of dry matter content and carotenoids in fresh cassava roots using a portable visible and near infrared spectrometer (Vis/NIRS).

    PubMed

    Ikeogu, Ugochukwu N; Davrieux, Fabrice; Dufour, Dominique; Ceballos, Hernan; Egesi, Chiedozie N; Jannink, Jean-Luc

    2017-01-01

    Portable Vis/NIRS are flexible tools for fast and unbiased analyses of constituents with minimal sample preparation. This study developed calibration models for dry matter content (DMC) and carotenoids in fresh cassava roots using a portable Vis/NIRS system. We examined the effects of eight data pre-treatment combinations on calibration models and assessed calibrations on processed and intact root samples. We compared Vis/NIRS derived-DMC to other phenotyping methods. The results of the study showed that the combination of standard normal variate and de-trend (SNVD) with first derivative calculated on two data points and no smoothing (SNVD+1111) was adequate for a robust model. Calibration performance was higher with processed than the intact root samples for all the traits although intact root models for some traits especially total carotenoid content (TCC) (R2c = 96%, R2cv = 90%, RPD = 3.6 and SECV = 0.63) were sufficient for screening purposes. Using three key quality traits as templates, we developed models with processed fresh root samples. Robust calibrations were established for DMC (R2c = 99%, R2cv = 95%, RPD = 4.5 and SECV = 0.9), TCC (R2c = 99%, R2cv = 91%, RPD = 3.5 and SECV = 2.1) and all Trans β-carotene (ATBC) (R2c = 98%, R2cv = 91%, RPD = 3.5 and SECV = 1.6). Coefficient of determination on independent validation set (R2p) for these traits were also satisfactory for ATBC (91%), TCC (88%) and DMC (80%). Compared to other methods, Vis/NIRS-derived DMC from both intact and processed roots had very high correlation (>0.95) with the ideal oven-drying than from specific gravity method (0.49). There was equally a high correlation (0.94) between the intact and processed Vis/NIRS DMC. Therefore, the portable Vis/NIRS could be employed for the rapid analyses of DMC and quantification of carotenoids in cassava for nutritional and breeding purposes.

  11. Detecting quinoxaline-2-carboxylic acid in animal tissues by using sensitive rapid enzyme-linked immunosorbent assay and time-resolved fluoroimmunoassay.

    PubMed

    Le, Tao; Yu, Huan; Niu, Xiaodong

    2015-05-15

    An indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and time-resolved fluoroimmunoassay (TR-FIA) based on an anti-N-butylquinoxaline-2-carboxamide (BQCA) monoclonal antibody were standardized and validated for quinoxaline-2-carboxylic acid (QCA) screening in animal tissues and its performance were compared to HPLC. The sensitivities obtained for edible tissue extracts were 1.62 and 1.12 ng ml(-1) for ic-ELISA and TR-FIA detection, respectively. Two samples were spiked with QCA and analyzed by both methods. The recovery values ranged from 92.6% to 112.2% and the coefficients of variation were less than 15% for QCA spiking into swine tissue samples at concentrations of 2.5-50.0 μg kg(-1). Excellent correlations (r(2)=0.987-0.996) of the ic-ELISA/HPLC and TR-FIA/HPLC data were observed for processed samples. The results demonstrated that the ic-ELISA and TR-FIA methods were rapid and accurate for the residue detection of QCA in animal tissues. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature.

    PubMed

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-05-06

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.

  13. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    NASA Astrophysics Data System (ADS)

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-05-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography.

  14. Ultrasonic acoustic levitation for fast frame rate X-ray protein crystallography at room temperature

    PubMed Central

    Tsujino, Soichiro; Tomizaki, Takashi

    2016-01-01

    Increasing the data acquisition rate of X-ray diffraction images for macromolecular crystals at room temperature at synchrotrons has the potential to significantly accelerate both structural analysis of biomolecules and structure-based drug developments. Using lysozyme model crystals, we demonstrated the rapid acquisition of X-ray diffraction datasets by combining a high frame rate pixel array detector with ultrasonic acoustic levitation of protein crystals in liquid droplets. The rapid spinning of the crystal within a levitating droplet ensured an efficient sampling of the reciprocal space. The datasets were processed with a program suite developed for serial femtosecond crystallography (SFX). The structure, which was solved by molecular replacement, was found to be identical to the structure obtained by the conventional oscillation method for up to a 1.8-Å resolution limit. In particular, the absence of protein crystal damage resulting from the acoustic levitation was carefully established. These results represent a key step towards a fully automated sample handling and measurement pipeline, which has promising prospects for a high acquisition rate and high sample efficiency for room temperature X-ray crystallography. PMID:27150272

  15. A rapid and efficient SDS-based RNA isolation protocol from different tissues of coffee.

    PubMed

    Huded, Arun Kumar C; Jingade, Pavankumar; Mishra, Manoj Kumar

    2018-03-01

    Isolation of high-quality RNA from coffee is challenging because of high level of polysaccharides, polyphenols and other secondary metabolites. In the present study, a rapid and efficient RNA extraction protocol from different tissues of coffee was optimized. Sufficiently high quality and quantity (225.6-454.8 µg/g) of RNA was obtained by using the optimized protocol. The presence of two distinct bands of 28S rRNA and 18S rRNA in agarose gel proved the intactness of the RNA samples. The average spectrophotometric values of the isolated RNA ranged from 1.96 to 2.02 ( A 260/280 ) and 1.95 to 2.14 ( A 260/230 ), indicating the high quality of RNA devoid of polyphenols, polysaccharides and protein contamination. In the optimized protocol, addition of PVPP to the extraction buffer and a brief incubation of samples at 65 °C and subsequent purification with potassium acetate resulted in good-quality RNA isolation. The suitability of RNA for downstream processing was confirmed by PCR amplification with cytochrome c oxidase gene-specific primers. The amplification of a single 392 bp fragment using cDNA and 1.5 kb fragment using genomic DNA samples confirmed the absence of DNA contamination. The present protocol is rapid and yielded good quality and quantity of RNA suitable for functional genomics studies.

  16. JMorph: Software for performing rapid morphometric measurements on digital images of fossil assemblages

    NASA Astrophysics Data System (ADS)

    Lelièvre, Peter G.; Grey, Melissa

    2017-08-01

    Quantitative morphometric analyses of form are widely used in palaeontology, especially for taxonomic and evolutionary research. These analyses can involve several measurements performed on hundreds or even thousands of samples. Performing measurements of size and shape on large assemblages of macro- or microfossil samples is generally infeasible or impossible with traditional instruments such as vernier calipers. Instead, digital image processing software is required to perform measurements via suitable digital images of samples. Many software packages exist for morphometric analyses but there is not much available for the integral stage of data collection, particularly for the measurement of the outlines of samples. Some software exists to automatically detect the outline of a fossil sample from a digital image. However, automatic outline detection methods may perform inadequately when samples have incomplete outlines or images contain poor contrast between the sample and staging background. Hence, a manual digitization approach may be the only option. We are not aware of any software packages that are designed specifically for efficient digital measurement of fossil assemblages with numerous samples, especially for the purposes of manual outline analysis. Throughout several previous studies, we have developed a new software tool, JMorph, that is custom-built for that task. JMorph provides the means to perform many different types of measurements, which we describe in this manuscript. We focus on JMorph's ability to rapidly and accurately digitize the outlines of fossils. JMorph is freely available from the authors.

  17. Rapid Assessment of Contaminants and Interferences in Mass Spectrometry Data Using Skyline

    NASA Astrophysics Data System (ADS)

    Rardin, Matthew J.

    2018-04-01

    Proper sample preparation in proteomic workflows is essential to the success of modern mass spectrometry experiments. Complex workflows often require reagents which are incompatible with MS analysis (e.g., detergents) necessitating a variety of sample cleanup procedures. Efforts to understand and mitigate sample contamination are a continual source of disruption with respect to both time and resources. To improve the ability to rapidly assess sample contamination from a diverse array of sources, I developed a molecular library in Skyline for rapid extraction of contaminant precursor signals using MS1 filtering. This contaminant template library is easily managed and can be modified for a diverse array of mass spectrometry sample preparation workflows. Utilization of this template allows rapid assessment of sample integrity and indicates potential sources of contamination. [Figure not available: see fulltext.

  18. Rapid analysis of sugars in honey by processing Raman spectrum using chemometric methods and artificial neural networks.

    PubMed

    Özbalci, Beril; Boyaci, İsmail Hakkı; Topcu, Ali; Kadılar, Cem; Tamer, Uğur

    2013-02-15

    The aim of this study was to quantify glucose, fructose, sucrose and maltose contents of honey samples using Raman spectroscopy as a rapid method. By performing a single measurement, quantifications of sugar contents have been said to be unaffordable according to the molecular similarities between sugar molecules in honey matrix. This bottleneck was overcome by coupling Raman spectroscopy with chemometric methods (principal component analysis (PCA) and partial least squares (PLS)) and an artificial neural network (ANN). Model solutions of four sugars were processed with PCA and significant separation was observed. This operation, done with the spectral features by using PLS and ANN methods, led to the discriminant analysis of sugar contents. Models/trained networks were created using a calibration data set and evaluated using a validation data set. The correlation coefficient values between actual and predicted values of glucose, fructose, sucrose and maltose were determined as 0.964, 0.965, 0.968 and 0.949 for PLS and 0.965, 0.965, 0.978 and 0.956 for ANN, respectively. The requirement of rapid analysis of sugar contents of commercial honeys has been met by the data processed within this article. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Crystal growth of intermetallic clathrates: Floating zone process and ultra rapid crystallization

    NASA Astrophysics Data System (ADS)

    Prokofiev, A.; Yan, X.; Ikeda, M.; Löffler, S.; Paschen, S.

    2014-09-01

    We studied the crystal growth process of type-I transition metal clathrates in two different regimes: a regime of moderate cooling rate, realized with the floating zone technique, and a regime of ultra rapid cooling, realized by the melt spinning technique. In the former regime, bulk Ba8AuxSi46-x and Ba8Cu4.8GaxGe41.2-x single crystals were grown. We investigated segregation effects of the constituting elements by measurements of the composition profiles along the growth direction. The compositional non-uniformity results in a spatial variation of the electrical resistivity which is discussed as well. Structural features of clathrates and their extremely low thermal conductivities imply specifics in growth behavior which manifest themselves most pronouncedly in a rapid crystallization process. Our melt spinning experiments on Ba8Au5Si41 and Ba8Ni3.5Si42.5 (and earlier on some other clathrates) have revealed surprisingly large grains of at least 1 μm. Because of the anomalously high growth rate of the clathrate phase the formation of impurity phases is considerably kinetically suppressed. We present our scanning and transmission electron microscopy investigations of melt spun samples and discuss structural, thermodynamic and kinetic aspects of the unusual clathrate nucleation and crystallization.

  20. Rapid analysis of ecstasy and related phenethylamines in seized tablets by Raman spectroscopy.

    PubMed

    Bell, S E; Burns, D T; Dennis, A C; Speers, J S

    2000-03-01

    Raman spectroscopy with far-red excitation has been used to study seized, tableted samples of MDMA (N-methyl-3,4-methylenedioxyamphetamine) and related compounds (MDA, MDEA, MBDB, 2C-B and amphetamine sulfate), as well as pure standards of these drugs. We have found that by using far-red (785 nm) excitation the level of fluorescence background even in untreated seized samples is sufficiently low that there is little difficulty in obtaining good quality data with moderate 2 min data accumulation times. The spectra can be used to distinguish between even chemically-similar substances, such as the geometrical isomers MDEA and MBDB, and between different polymorphic/hydrated forms of the same drug. Moreover, these differences can be found even in directly recorded spectra of seized samples which have been bulked with other materials, giving a rapid and non-destructive method for drug identification. The spectra can be processed to give unambiguous identification of both drug and excipients (even when more than one compound has been used as the bulking agent) and the relative intensities of drug and excipient bands can be used for quantitative or at least semi-quantitative analysis. Finally, the simple nature of the measurements lends itself to automatic sample handling so that sample throughputs of 20 samples per hour can be achieved with no real difficulty.

  1. A rapid analytical method to quantify complex organohalogen contaminant mixtures in large samples of high lipid mammalian tissues.

    PubMed

    Desforges, Jean-Pierre; Eulaers, Igor; Periard, Luke; Sonne, Christian; Dietz, Rune; Letcher, Robert J

    2017-06-01

    In vitro investigations of the health impact of individual chemical compounds have traditionally been used in risk assessments. However, humans and wildlife are exposed to a plethora of potentially harmful chemicals, including organohalogen contaminants (OHCs). An alternative exposure approach to individual or simple mixtures of synthetic OHCs is to isolate the complex mixture present in free-ranging wildlife, often non-destructively sampled from lipid rich adipose. High concentration stock volumes required for in vitro investigations do, however, pose a great analytical challenge to extract sufficient amounts of complex OHC cocktails. Here we describe a novel method to easily, rapidly and efficiently extract an environmentally accumulated and therefore relevant contaminant cocktail from large (10-50 g) marine mammal blubber samples. We demonstrate that lipid freeze-filtration with acetonitrile removes up to 97% of blubber lipids, with minimal effect on the efficiency of OHC recovery. Sample extracts after freeze-filtration were further processed to remove residual trace lipids via high-pressure gel permeation chromatography and solid phase extraction. Average recoveries of OHCs from triplicate analysis of killer whale (Orcinus orca), polar bear (Ursus maritimus) and pilot whale (Globicephala spp.) blubber standard reference material (NIST SRM-1945) ranged from 68 to 80%, 54-92% and 58-145%, respectively, for 13 C-enriched internal standards of six polychlorinated biphenyl congeners, 16 organochlorine pesticides and four brominated flame retardants. This approach to rapidly generate OHC mixtures shows great potential for experimental exposures using complex contaminant mixtures, research or monitoring driven contaminant quantification in biological samples, as well as the untargeted identification of emerging contaminants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Air-assisted liquid-liquid microextraction by solidifying the floating organic droplets for the rapid determination of seven fungicide residues in juice samples.

    PubMed

    You, Xiangwei; Xing, Zhuokan; Liu, Fengmao; Zhang, Xu

    2015-05-22

    A novel air assisted liquid-liquid microextraction using the solidification of a floating organic droplet method (AALLME-SFO) was developed for the rapid and simple determination of seven fungicide residues in juice samples, using the gas chromatography with electron capture detector (GC-ECD). This method combines the advantages of AALLME and dispersive liquid-liquid microextraction based on the solidification of floating organic droplets (DLLME-SFO) for the first time. In this method, a low-density solvent with a melting point near room temperature was used as the extraction solvent, and the emulsion was rapidly formed by pulling in and pushing out the mixture of aqueous sample solution and extraction solvent for ten times repeatedly using a 10-mL glass syringe. After centrifugation, the extractant droplet could be easily collected from the top of the aqueous samples by solidifying it at a temperature lower than the melting point. Under the optimized conditions, good linearities with the correlation coefficients (γ) higher than 0.9959 were obtained and the limits of detection (LOD) varied between 0.02 and 0.25 μgL(-1). The proposed method was applied to determine the target fungicides in juice samples and acceptable recoveries ranged from 72.6% to 114.0% with the relative standard deviations (RSDs) of 2.3-13.0% were achieved. Compared with the conventional DLLME method, the newly proposed method will neither require a highly toxic chlorinated solvent for extraction nor an organic dispersive solvent in the application process; hence, it is more environmentally friendly. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Carbon isotope analyses of n-alkanes released from rapid pyrolysis of oil asphaltenes in a closed system.

    PubMed

    Chen, Shasha; Jia, Wanglu; Peng, Ping'an

    2016-08-15

    Carbon isotope analysis of n-alkanes produced by the pyrolysis of oil asphaltenes is a useful tool for characterizing and correlating oil sources. Low-temperature (320-350°C) pyrolysis lasting 2-3 days is usually employed in such studies. Establishing a rapid pyrolysis method is necessary to reduce the time taken for the pretreatment process in isotope analyses. One asphaltene sample was pyrolyzed in sealed ampoules for different durations (60-120 s) at 610°C. The δ(13) C values of the pyrolysates were determined by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The molecular characteristics and isotopic signatures of the pyrolysates were investigated for the different pyrolysis durations and compared with results obtained using the normal pyrolysis method, to determine the optimum time interval. Several asphaltene samples derived from various sources were analyzed using this method. The asphaltene pyrolysates of each sample were similar to those obtained by the flash pyrolysis method on similar samples. However, the molecular characteristics of the pyrolysates obtained over durations longer than 90 s showed intensified secondary reactions. The carbon isotopic signatures of individual compounds obtained at pyrolysis durations less than 90 s were consistent with those obtained from typical low-temperature pyrolysis. Several asphaltene samples from various sources released n-alkanes with distinct carbon isotopic signatures. This easy-to-use pyrolysis method, combined with a subsequent purification procedure, can be used to rapidly obtain clean n-alkanes from oil asphaltenes. Carbon isotopic signatures of n-alkanes released from oil asphaltenes from different sources demonstrate the potential application of this method in 'oil-oil' and 'oil-source' correlations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Validation of a Rapid Bacteria Endospore Enumeration System for Planetary Protection Application

    NASA Astrophysics Data System (ADS)

    Chen, Fei; Kern, Roger; Kazarians, Gayane; Venkateswaran, Kasthuri

    NASA monitors spacecraft surfaces to assure that the presence of bacterial endospores meets strict criteria at launch, to minimize the risk of inadvertent contamination of the surface of Mars. Currently, the only approved method for enumerating the spores is a culture based assay that requires three days to produce results. In order to meet the demanding schedules of spacecraft assembly, a more rapid spore detection assay is being considered as an alternate method to the NASA standard culture-based assay. The Millipore Rapid Microbiology Detection System (RMDS) has been used successfully for rapid bioburden enumeration in the pharmaceutical and food industries. The RMDS is rapid and simple, shows high sensitivity (to 1 colony forming unit [CFU]/sample), and correlates well with traditional culture-based methods. It combines membrane filtration, adenosine triphosphate (ATP) bioluminescence chemistry, and image analysis based on photon detection with a Charge Coupled Device (CCD) camera. In this study, we have optimized the assay conditions and evaluated the use of the RMDS as a rapid spore detection tool for NASA applications. In order to select for spores, the samples were subjected to a heat shock step before proceeding with the RMDS incubation protocol. Seven species of Bacillus (nine strains) that have been repeatedly isolated from clean room environments were assayed. All strains were detected by the RMDS in 5 hours and these assay times were repeatedly demonstrated along with low image background noise. Validation experiments to compare the Rapid Sore Assay (RSA) and NASA standard assay (NSA) were also performed. The evaluation criteria were modeled after the FDA Guideline of Process Validation, and Analytical Test Methods. This body of research demonstrates that the Rapid Spore Assay (RSA) is quick, and of equivalent sensitivity to the NASA standard assay, potentially reducing the assay time for bacterial endospores from over 72 hours to less than 8 hours. Accordingly, JPL has produced a report recommending that NASA adopt the RSA method as a suitable alternative to the NASA standard assay.

  5. Application of Solid Phase Microextraction Coupled with Gas Chromatography/Mass Spectrometry as a Rapid Method for Field Sampling and Analysis of Chemical Warfare Agents and Toxic Industrial Chemicals

    DTIC Science & Technology

    2003-01-01

    PHASE MICROEXTRACTION COUPLED WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY AS A RAPID METHOD FOR FIELD SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS...SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...GAS CHROMATOGRAPHY/MASS SPECTROMETRY AS A RAPID METHOD FOR FIELD SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS

  6. Rapid detection of Ebola virus with a reagent-free, point-of-care biosensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baca, Justin T.; Severns, Virginia; Lovato, Debbie

    Surface acoustic wave (SAW) sensors can rapidly detect Ebola antigens at the point-of-care without the need for added reagents, sample processing, or specialized personnel. This preliminary study demonstrates SAW biosensor detection of the Ebola virus in a concentration-dependent manner. The detection limit with this methodology is below the average level of viremia detected on the first day of symptoms by PCR. We observe a log-linear sensor response for highly fragmented Ebola viral particles, with a detection limit corresponding to 1.9 × 10⁴ PFU/mL prior to virus inactivation. We predict greatly improved sensitivity for intact, infectious Ebola virus. This point-of-care methodologymore » has the potential to detect Ebola viremia prior to symptom onset, greatly enabling infection control and rapid treatment. This biosensor platform is powered by disposable AA batteries and can be rapidly adapted to detect other emerging diseases in austere conditions.« less

  7. Rapid detection of Ebola virus with a reagent-free, point-of-care biosensor

    DOE PAGES

    Baca, Justin T.; Severns, Virginia; Lovato, Debbie; ...

    2015-04-14

    Surface acoustic wave (SAW) sensors can rapidly detect Ebola antigens at the point-of-care without the need for added reagents, sample processing, or specialized personnel. This preliminary study demonstrates SAW biosensor detection of the Ebola virus in a concentration-dependent manner. The detection limit with this methodology is below the average level of viremia detected on the first day of symptoms by PCR. We observe a log-linear sensor response for highly fragmented Ebola viral particles, with a detection limit corresponding to 1.9 × 10⁴ PFU/mL prior to virus inactivation. We predict greatly improved sensitivity for intact, infectious Ebola virus. This point-of-care methodologymore » has the potential to detect Ebola viremia prior to symptom onset, greatly enabling infection control and rapid treatment. This biosensor platform is powered by disposable AA batteries and can be rapidly adapted to detect other emerging diseases in austere conditions.« less

  8. Rapid determination of yunaconitine and related alkaloids in aconites and aconite-containing drugs by ultra high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Song, Long; Zhang, Hong; Liu, Xin; Zhao, Zhi-Li; Chen, Shi-Lin; Wang, Zheng-Tao; Xu, Hong-Xi

    2012-12-01

    Yunaconitine (YAC) is a toxic aconite alkaloid that is considered to be a hidden aconite poison since it is frequently found in body fluids from aconite poisoning patients, but has not been well studied in commonly used herbal drugs. In this paper, a rapid and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection combined with microwave-assisted extraction (MAE) was developed for high throughput simultaneous determination of YAC and six other toxic aconite alkaloids in 31 samples of crude, processed aconites and aconite-containing drugs. The optimized method showed excellent linearity, precision, accuracy and recovery for all target compounds with short run time. YAC was detected in some samples with contents from 0.015 to 10.41 mg/g. This is the first report on the determination of YAC in Radix Aconiti, Radix Aconiti Kusnezoffii and aconite-containing drugs. This newly developed method facilitates the rapid screening of YAC and related toxic aconite alkaloids and allows YAC to be used as a chemical marker for the quality control of aconites and aconite-containing drugs. Copyright © 2012 John Wiley & Sons, Ltd.

  9. SDSS-IV MaNGA: the different quenching histories of fast and slow rotators

    NASA Astrophysics Data System (ADS)

    Smethurst, R. J.; Masters, K. L.; Lintott, C. J.; Weijmans, A.; Merrifield, M.; Penny, S. J.; Aragón-Salamanca, A.; Brownstein, J.; Bundy, K.; Drory, N.; Law, D. R.; Nichol, R. C.

    2018-01-01

    Do the theorized different formation mechanisms of fast and slow rotators produce an observable difference in their star formation histories? To study this, we identify quenching slow rotators in the MaNGA sample by selecting those that lie below the star-forming sequence and identify a sample of quenching fast rotators that were matched in stellar mass. This results in a total sample of 194 kinematically classified galaxies, which is agnostic to visual morphology. We use u - r and NUV - u colours from the Sloan Digital Sky Survey and GALEX and an existing inference package, STARPY, to conduct a first look at the onset time and exponentially declining rate of quenching of these galaxies. An Anderson-Darling test on the distribution of the inferred quenching rates across the two kinematic populations reveals they are statistically distinguishable (3.2σ). We find that fast rotators quench at a much wider range of rates than slow rotators, consistent with a wide variety of physical processes such as secular evolution, minor mergers, gas accretion and environmentally driven mechanisms. Quenching is more likely to occur at rapid rates (τ ≲ 1 Gyr) for slow rotators, in agreement with theories suggesting slow rotators are formed in dynamically fast processes, such as major mergers. Interestingly, we also find that a subset of the fast rotators quench at these same rapid rates as the bulk of the slow rotator sample. We therefore discuss how the total gas mass of a merger, rather than the merger mass ratio, may decide a galaxy's ultimate kinematic fate.

  10. In-capillary derivatization with o-phthalaldehyde in the presence of 3-mercaptopropionic acid for the simultaneous determination of monosodium glutamate, benzoic acid, and sorbic acid in food samples via capillary electrophoresis with ultraviolet detection.

    PubMed

    Aung, Hnin-Pwint; Pyell, Ute

    2016-06-03

    For the rapid simultaneous determination of monosodium glutamate (MSG), benzoic acid (BA), and sorbic acid (SA) in canned food and other processed food samples, we developed a method that combines in-capillary derivatization with separation by capillary electrophoresis. This method employs the rapid derivatization of MSG with o-phthalaldehyde (OPA) in the presence of 3-mercaptopropionic acid (3-MPA) and enables the detection of the resulting OPA-MSG derivative and of non-derivatized BA and SA at 230nm. The composition of the background electrolyte and the parameters of derivatization and separation are as follows: 25mM borax containing 5mM OPA and 6mM 3-MPA, separation voltage 25mV, injection at 30mbar for 20s, and column temperature 25°C. Because of the high reaction rate and suitably adapted effective electrophoretic mobilities, band broadening due to the derivatization reaction at the start of the separation process is kept to a minimum. The optimized method is validated with respect to LOD, LOQ, linearity, recovery, and precision. This method can be applied to real samples such as soy, fish, oyster and sweet and sour chili sauces after application of appropriate clean-up steps. Mechanisms of zone broadening and zone focusing are discussed showing the validity of the employed theoretical approach regarding the dependence of the peak shape for OPA-MSG on the concentration of MSG in the sample. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Species detection using HyBeacon(®) probe technology: Working towards rapid onsite testing in non-human forensic and food authentication applications.

    PubMed

    Dawnay, Nick; Hughes, Rebecca; Court, Denise Syndercombe; Duxbury, Nicola

    2016-01-01

    Identifying individual species or determining species' composition in an unknown sample is important for a variety of forensic applications. Food authentication, monitoring illegal trade in endangered species, forensic entomology, sexual assault case work and counter terrorism are just some of the fields that can require the detection of the biological species present. Traditional laboratory based approaches employ a wide variety of tools and technologies and exploit a number of different species specific traits including morphology, molecular differences and immuno-chemical analyses. A large number of these approaches require laboratory based apparatus and results can take a number of days to be returned to investigating authorities. Having a presumptive test for rapid identification could lead to savings in terms of cost and time and allow sample prioritisation if confirmatory testing in a laboratory is required later. This model study describes the development of an assay using a single HyBeacon(®) probe and melt curve analyses allowing rapid screening and authentication of food products labelled as Atlantic cod (Gadus morhua). Exploiting melt curve detection of species specific SNP sites on the COI gene the test allows detection of a target species (Atlantic cod) and closely related species which may be used as substitutes. The assay has been designed for use with the Field Portable ParaDNA system, a molecular detection platform for non-expert users. The entire process from sampling to result takes approximately 75min. Validation studies were performed on both single source genomic DNA, mixed genomic DNA and commercial samples. Data suggests the assay has a lower limit of detection of 31 pg DNA. The specificity of the assay to Atlantic cod was measured by testing highly processed food samples including frozen, defrosted and cooked fish fillets as well as fish fingers, battered fish fillet and fish pie. Ninety-six (92.7%) of all Atlantic cod food products, tested, provided a correct single species result with the remaining samples erroneously identified as containing non-target species. The data shows that the assay was quick to design and characterise and is also capable of yielding results that would be beneficial in a variety of fields, not least the authentication of food. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Containerless Processing: Fabrication of Advanced Functional Materials from Undercooled Oxide Melt

    NASA Astrophysics Data System (ADS)

    Kumar, M. S. Vijaya; Ishikawa, Takehiko; Yoda, Shinichi; Kuribayashi, Kazuhiko

    2012-07-01

    Materials science in Microgravity condition is one of newly established cutting edge science field. After the effort of space development and space utilization, microgravity of space environment has been considered as one of novel tools for materials science because it assures containerless levitation. Containerless processing is a promising technique to explore the technologically important materials using rapid solidification of an undercooled melt. Recently, rare-earth ferrites and manganites have attracted great interest towards their wide applications in the field of electronic industry. Among these new hexagonal phases with a space group of P6 _{3}cm are technologically important materials because of multiferroic characteristics, i.e., the coexistence of ferroelectricity and magnetism in one compound. In the present study, containerless solidification of the R-Fe-O, and R-Mn-O melts were carried out to fabricate multiferroics under the controlled Po _{2}. Containerless processing is a promising technique to explore the new materials using rapid solidification of an undercooled melt because it provides large undercooling prior to nucleation. In order to undercool the melt deeply below the melting temperature under a precisely controlled oxygen partial pressure, an aerodynamic levitator (ADL) combined with ZrO _{2} oxygen sensor was designed. A spherical RFeO _{3} and RMnO _{3} sample was levitated by an ADL and completely melted by a CO _{2} laser in an atmosphere with predetermined Po _{2}.The surface temperature of the levitated droplet was monitored by a two-color pyrometer. Then, the droplet was cooled by turning off the CO _{2} laser. The XRD results of the rapidly solidified LuFeO _{3} and LuMnO _{3} samples at Po _{2} of 1x10 ^{5} Pa confirms the existence of the hexagonal metastable LuFeO _{3} phase. On the other hand, orthorhombic RFeO _{3} (R=Yb, Er, Y and Dy)and hexagonal RMnO _{3} (R=Ho-Lu)phases were identified. The cross-sectioned scanning electron microscopy (SEM) images and TG/DTA results revealed the existence of the stable and metastable phases with decreasing Po _{2}. The magnetic properties of the as-solidified samples were studied using vibrating sample magnetometer (VSM). These results indicate that a metastable and stable phase solidifies directly from the undercooled melt even when the melt is undercooled much below the peritectic temperature.

  13. The effect of processing on the surface physical stability of amorphous solid dispersions.

    PubMed

    Yang, Ziyi; Nollenberger, Kathrin; Albers, Jessica; Moffat, Jonathan; Craig, Duncan; Qi, Sheng

    2014-11-01

    The focus of this study was to investigate the effect of processing on the surface crystallization of amorphous molecular dispersions and gain insight into the mechanisms underpinning this effect. The model systems, amorphous molecular dispersions of felodipine-EUDRAGIT® E PO, were processed both using spin coating (an ultra-fast solvent evaporation based method) and hot melt extrusion (HME) (a melting based method). Amorphous solid dispersions with drug loadings of 10-90% (w/w) were obtained by both processing methods. Samples were stored under 75% RH/room temperatures for up to 10months. Surface crystallization was observed shortly after preparation for the HME samples with high drug loadings (50-90%). Surface crystallization was characterized by powder X-ray diffraction (PXRD), ATR-FTIR spectroscopy and imaging techniques (SEM, AFM and localized thermal analysis). Spin coated molecular dispersions showed significantly higher surface physical stability than hot melt extruded samples. For both systems, the progress of the surface crystal growth followed zero order kinetics on aging. Drug enrichment at the surfaces of HME samples on aging was observed, which may contribute to surface crystallization of amorphous molecular dispersions. In conclusion it was found the amorphous molecular dispersions prepared by spin coating had a significantly higher surface physical stability than the corresponding HME samples, which may be attributed to the increased process-related apparent drug-polymer solubility and reduced molecular mobility due to the quenching effect caused by the rapid solvent evaporation in spin coating. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity.

    PubMed

    Hausman, Debra S; Cambron, R Thomas; Sakr, Adel

    2005-07-14

    On-line Raman spectroscopy was used to evaluate the effect of blending time on low dose, 1%, blend uniformity of azimilide dihydrochloride. An 8 qt blender was used for the experiments and instrumented with a Raman probe through the I-bar port. The blender was slowed to 6.75 rpm to better illustrate the blending process (normal speed is 25 rpm). Uniformity was reached after 20 min of blending at 6.75 rpm (135 revolutions or 5.4 min at 25 rpm). On-line Raman analysis of blend uniformity provided more benefits than traditional thief sampling and off-line analysis. On-line Raman spectroscopy enabled generating data rich blend profiles, due to the ability to collect a large number of samples during the blending process (sampling every 20s). In addition, the Raman blend profile was rapidly generated, compared to the lengthy time to complete a blend profile with thief sampling and off-line analysis. The on-line Raman blend uniformity results were also significantly correlated (p-value < 0.05) to the HPLC uniformity results of thief samples.

  15. Development of homologous viral internal controls for use in RT-PCR assays of waterborne enteric viruses.

    PubMed

    Parshionikar, Sandhya U; Cashdollar, Jennifer; Fout, G Shay

    2004-10-01

    Enteric viruses often contaminate water sources causing frequent outbreaks of gastroenteritis. Reverse transcription-polymerase chain reaction (RT-PCR) assays are commonly used for detection of human enteric viruses in environmental and drinking water samples. RT-PCR provides a means to rapidly detect low levels of these viruses, but it is sensitive to inhibitors that are present in water samples. Inhibitors of RT-PCR are concentrated along with viruses during sample processing. While procedures have been developed to remove inhibitors, none of them completely remove all inhibitors from all types of water matrices. This problem requires that adequate controls be used to distinguish true from potentially false-negative results. To address this problem, we have developed homologous viral internal controls for hepatitis A virus (HAV), poliovirus, Norwalk virus and rotavirus. These internal controls can be used in RT-PCR assays for the detection of the above viruses by competitive amplification, thereby allowing the detection of false negatives in processed water samples. The internal controls developed in this study were successfully tested with virus-seeded environmental water sample concentrates.

  16. Geologic controls on the formation and evolution of quaternary coastal deposits of the northern Gulf of Mexico

    USGS Publications Warehouse

    Williams, S.J.; Penland, S.; Sallenger, A.H.; McBride, R.A.; Kindlinger, J.L.

    1991-01-01

    A study of the barrier islands and wetlands in the deltaic plain of Louisiana is presented. Its purpose was to document rapid changes and to learn more about the processes responsible and the geologic framework within which they operate. It included systematic collection and analysis of precision nearshore hydrographic data, high resolution seismic profiles, surface sediment samples, continuous vibracores, digital shoreline plots, records of storm overwash events, and analysis of tide gage records to quantify the rise in relative sea level. Results from these studies demonstrate that deltaic progradation, river channel switching, and subsequent rapid erosion accompanying the marine transgression are regular and predictable events along the Mississippi River delta plain and will likely continue in the future. Mitigation measures, such as shoreline nourishment and barrier restoration, that mimic the natural processes may slow the land loss.

  17. Data warehousing methods and processing infrastructure for brain recovery research.

    PubMed

    Gee, T; Kenny, S; Price, C J; Seghier, M L; Small, S L; Leff, A P; Pacurar, A; Strother, S C

    2010-09-01

    In order to accelerate translational neuroscience with the goal of improving clinical care it has become important to support rapid accumulation and analysis of large, heterogeneous neuroimaging samples and their metadata from both normal control and patient groups. We propose a multi-centre, multinational approach to accelerate the data mining of large samples and facilitate data-led clinical translation of neuroimaging results in stroke. Such data-driven approaches are likely to have an early impact on clinically relevant brain recovery while we simultaneously pursue the much more challenging model-based approaches that depend on a deep understanding of the complex neural circuitry and physiological processes that support brain function and recovery. We present a brief overview of three (potentially converging) approaches to neuroimaging data warehousing and processing that aim to support these diverse methods for facilitating prediction of cognitive and behavioral recovery after stroke, or other types of brain injury or disease.

  18. A multiplex PCR method for the identification of commercially important salmon and trout species (Oncorhynchus and Salmo) in North America.

    PubMed

    Rasmussen Hellberg, Rosalee S; Morrissey, Michael T; Hanner, Robert H

    2010-09-01

    The purpose of this study was to develop a species-specific multiplex polymerase chain reaction (PCR) method that allows for the detection of salmon species substitution on the commercial market. Species-specific primers and TaqMan® probes were developed based on a comprehensive collection of mitochondrial 5' cytochrome c oxidase subunit I (COI) deoxyribonucleic acid (DNA) "barcode" sequences. Primers and probes were combined into multiplex assays and tested for specificity against 112 reference samples representing 25 species. Sensitivity and linearity tests were conducted using 10-fold serial dilutions of target DNA (single-species samples) and DNA admixtures containing the target species at levels of 10%, 1.0%, and 0.1% mixed with a secondary species. The specificity tests showed positive signals for the target DNA in both real-time and conventional PCR systems. Nonspecific amplification in both systems was minimal; however, false positives were detected at low levels (1.2% to 8.3%) in conventional PCR. Detection levels were similar for admixtures and single-species samples based on a 30 PCR cycle cut-off, with limits of 0.25 to 2.5 ng (1% to 10%) in conventional PCR and 0.05 to 5.0 ng (0.1% to 10%) in real-time PCR. A small-scale test with food samples showed promising results, with species identification possible even in heavily processed food items. Overall, this study presents a rapid, specific, and sensitive method for salmon species identification that can be applied to mixed-species and heavily processed samples in either conventional or real-time PCR formats. This study provides a newly developed method for salmon and trout species identification that will assist both industry and regulatory agencies in the detection and prevention of species substitution. This multiplex PCR method allows for rapid, high-throughput species identification even in heavily processed and mixed-species samples. An inter-laboratory study is currently being carried out to assess the ability of this method to identify species in a variety of commercial salmon and trout products.

  19. Use of rapid-scan EPR to improve detection sensitivity for spin-trapped radicals.

    PubMed

    Mitchell, Deborah G; Rosen, Gerald M; Tseitlin, Mark; Symmes, Breanna; Eaton, Sandra S; Eaton, Gareth R

    2013-07-16

    The short lifetime of superoxide and the low rates of formation expected in vivo make detection by standard continuous wave (CW) electron paramagnetic resonance (EPR) challenging. The new rapid-scan EPR method offers improved sensitivity for these types of samples. In rapid-scan EPR, the magnetic field is scanned through resonance in a time that is short relative to electron spin relaxation times, and data are processed to obtain the absorption spectrum. To validate the application of rapid-scan EPR to spin trapping, superoxide was generated by the reaction of xanthine oxidase and hypoxanthine with rates of 0.1-6.0 μM/min and trapped with 5-tert-butoxycarbonyl-5-methyl-1-pyrroline-N-oxide (BMPO). Spin trapping with BMPO to form the BMPO-OOH adduct converts the very short-lived superoxide radical into a more stable spin adduct. There is good agreement between the hyperfine splitting parameters obtained for BMPO-OOH by CW and rapid-scan EPR. For the same signal acquisition time, the signal/noise ratio is >40 times higher for rapid-scan than for CW EPR. Rapid-scan EPR can detect superoxide produced by Enterococcus faecalis at rates that are too low for detection by CW EPR. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Processing Sentinel-2 data with ATCOR

    NASA Astrophysics Data System (ADS)

    Pflug, Bringfried; Makarau, Aliaksei; Richter, Rudolf

    2016-04-01

    Atmospheric correction of satellite images is necessary for many applications of remote sensing. Among them are applications for agriculture, forestry, land cover and land cover change, urban mapping, emergency and inland water. ATCOR is a widely used atmospheric correction tool which can process data of many optical satellite sensors, for instance Landsat, Sentinel-2, SPOT and RapidEye. ATCOR includes a terrain and adjacency correction of satellite images and several special algorithms like haze detection, haze correction, cirrus correction, de-shadowing and empirical methods for BRDF correction. The atmospheric correction tool ATCOR starts with an estimation of the vertical column Aerosol Optical Thickness (AOT550) at 550 nm. The mean uncertainty of the ATCOR-AOT550-estimation was estimated using Landsat and RapidEye data by direct comparison with sunphotometer data as a reference. For Landsat and RapidEye the uncertainty is ΔAOT550nm ≈ 0.03±0.02 for cloudless conditions with a cloud+haze fraction below 1%. Inclusion of cloudy and hazy satellite images into the analysis results in mean ΔAOT550nm ≈ 0.04±0.03 for both RapidEye and Landsat imagery. About 1/3 of the samples perform with the AOT uncertainty better than 0.02 and about 2/3 perform with AOT uncertainty better than 0.05. An accuracy of the retrieved surface reflectance of ±2% (for reflectance <10%) and ±4% reflectance units (for reflectance > 40%) can be achieved for flat terrain, and avoiding the specular and backscattering regions. ATCOR also supports the processing of Sentinel-2 data. First results of processing S2 data and a comparison with AERONET AOT values will be presented.

  1. Pathology in a tube step 2: simple rapid fabrication of curved circular cross section millifluidic channels for biopsy preparation/3D imaging towards pancreatic cancer detection and diagnosis

    NASA Astrophysics Data System (ADS)

    Das, Ronnie; Burfeind, Chris W.; Lim, Saniel D.; Patle, Shubham; Seibel, Eric J.

    2018-02-01

    3D pathology is intrinsically dependent on 3D microscopy, or the whole tissue imaging of patient tissue biopsies (TBs). Consequently, unsectioned needle specimens must be processed whole: a procedure which cannot necessarily be accomplished through manual methods, or by retasking automated pathology machines. Thus "millifluidic" devices (for millimeter-scale biopsies) are an ideal solution for tissue handling/preparation. TBs are large, messy and a solid-liquid mixture; they vary in material, geometry and structure based on the organ biopsied, the clinician skill and the needle type used. As a result, traditional microfluidic devices are insufficient to handle such mm-sized samples and their associated fabrication techniques are impractical and costly with respect to time/efficiency. Our research group has devised a simple, rapid fabrication process for millifluidic devices using jointed skeletal molds composed of machined, reusable metal rods, segmented rods and stranded wire as structural cores; these cores are surrounded by Teflon outer housing. We can therefore produce curving, circular-cross-section (CCCS) millifluidic channels in rapid fashion that cannot normally be achieved by microfabrication, micro-/CNC-machining, or 3D printing. The approach has several advantages. CLINICAL: round channels interface coring needles. PROCESSING: CCCS channels permit multi-layer device designs for additional (processing, monitoring, testing) stages. REUSABILITY: for a biopsy/needle diameter, molding (interchangeable) components may be produced one-time then reused for other designs. RAPID: structural cores can be quickly removed due to Teflon®'s ultra-low friction; housing may be released with ethanol; PDMS volumes cure faster since metal skeleton molds conduct additional heat from within the curing elastomer.

  2. Rapid screening and identification of chemical hazards in surface and drinking water using high resolution mass spectrometry and a case-control filter.

    PubMed

    Kaserzon, Sarit L; Heffernan, Amy L; Thompson, Kristie; Mueller, Jochen F; Gomez Ramos, Maria Jose

    2017-09-01

    Access to clean, safe drinking water poses a serious challenge to regulators, and requires analytical strategies capable of rapid screening and identification of potentially hazardous chemicals, specifically in situations when threats to water quality or security require rapid investigations and potential response. This study describes a fast and efficient chemical hazard screening strategy for characterising trace levels of polar organic contaminants in water matrices, based on liquid chromatography high resolution mass spectrometry with post-acquisition 'case-control' data processing. This method allowed for a rapid response time of less than 24 h for the screening of target, suspect and non-target unknown chemicals via direct injection analysis, and a second, more sensitive analysis option requiring sample pre-concentration. The method was validated by fortifying samples with a range of pesticides, pharmaceuticals and personal care products (n = 46); with >90% of target compounds positively screened in samples at 1 ng mL -1 , and 46% at 0.1 ng mL -1 when analysed via direct injection. To simulate a contamination event samples were fortified with compounds not present in the commercial library (designated 'non-target compounds'; fipronil and fenitrothion), tentatively identified at 0.2 and 1 ng mL -1 , respectively; and a compound not included in any known commercial library or public database (designated 'unknown' compounds; 8Cl - perfluorooctanesulfonic acid), at 0.8 ng mL -1 . The method was applied to two 'real-case' scenarios: (1) the assessment of drinking water safety during a high-profile event in Brisbane, Australia; and (2) to screen treated, re-circulated drinking water and pre-treated (raw) water. The validated workflow was effective for rapid prioritisation and screening of suspect and non-target potential hazards at trace levels, and could be applied to a wide range of matrices and investigations where comparison of organic contaminants between an affected and control site and or timeframe is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Perception of non-verbal auditory stimuli in Italian dyslexic children.

    PubMed

    Cantiani, Chiara; Lorusso, Maria Luisa; Valnegri, Camilla; Molteni, Massimo

    2010-01-01

    Auditory temporal processing deficits have been proposed as the underlying cause of phonological difficulties in Developmental Dyslexia. The hypothesis was tested in a sample of 20 Italian dyslexic children aged 8-14, and 20 matched control children. Three tasks of auditory processing of non-verbal stimuli, involving discrimination and reproduction of sequences of rapidly presented short sounds were expressly created. Dyslexic subjects performed more poorly than control children, suggesting the presence of a deficit only partially influenced by the duration of the stimuli and of inter-stimulus intervals (ISIs).

  4. An electrochemical and structural study of highly uniform tin oxide nanowires fabricated by a novel, scalable solvoplasma technique as anode material for sodium ion batteries

    NASA Astrophysics Data System (ADS)

    Mukherjee, Santanu; Schuppert, Nicholas; Bates, Alex; Jasinski, Jacek; Hong, Jong-Eun; Choi, Moon Jong; Park, Sam

    2017-04-01

    A novel solvoplasma based technique was used to fabricate highly uniform SnO2 nanowires (NWs) for application as an anode in sodium-ion batteries (SIBs). This technique is scalable, rapid, and utilizes a rigorous cleaning process to produce very pure SnO2 NWs with enhanced porosity; which improves sodium-ion hosting and reaction kinetics. The batch of NWs obtained from the plasma process were named the "as-made" sample and after cleaning the "pure" sample. Structural characterization showed that the as-made sample has a K+ ion impurity which is absent in the pure samples. The pure samples have a higher maximum specific capacity, 400.71 mAhg-1, and Coulombic efficiency, 85%, compared to the as-made samples which have a maximum specific capacity of 174.69 mAhg-1 and Coulombic efficiency of 74% upon cycling. A study of the electrochemical impedance spectra showed that the as-made samples have a higher interfacial and diffusion resistance than the pure samples and resistances increased after 50 cycles of cell operation for both samples due to progressive electrode degradation. Specific energy vs specific power plots were employed to analyze the performance of the system with respect to the working conditions.

  5. Ultrasonic cavitation erosion-corrosion behavior of friction stir processed stainless steel.

    PubMed

    Selvam, Karthikeyan; Mandal, Priya; Grewal, Harpreet Singh; Arora, Harpreet Singh

    2018-06-01

    Cavitation erosion remains the primary cause of material degradation in fluid machinery components operating at high speed. Micro-jets/shock waves caused by implosion of bubbles on material surface results in significant material loss and premature failure of the components. The presence of corrosive medium further exuberates this effect, causing rapid degradation. Here, we demonstrate a novel pathway to control cavitation erosion-corrosion by tailoring the surface properties using submerged friction stir processing (FSP), a severe plastic deformation process. FSP parameters were varied over wide range of strain-rates to generate tailored microstructures. High strain-rate processing resulted in nearly single phase fine grained structure while low strain-rate processing resulted in phase transformation in addition to grain refinement. As-received and processed samples were subjected to ultrasonic cavitation in distilled water as well as in corrosive environment of 3.5% NaCl solution. Individual roles of cavitation erosion, corrosion and their synergistic effects were analyzed. Depending on the microstructure, processed samples showed nearly 4-6 times higher cavitation erosion resistance compared to as-received alloy. Superior cavitation erosion-corrosion resistance of processed samples was attributed to surface strengthening, higher strain-hardening ability and quick passivation kinetics. The results of current study could be potentially transformative in designing robust materials for hydro-dynamic applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. An Experimental Investigation of the Process of Isotope Exchange that Takes Place when Heavy Water Is Exposed to the Atmosphere

    ERIC Educational Resources Information Center

    Deeney, F. A.; O'Leary, J. P.

    2009-01-01

    We have used the recently developed method for rapid measurement of maximum density temperature to determine the rate at which hydrogen and deuterium isotope exchange takes place when a sample of heavy water is exposed to the atmosphere. We also provide a simple explanation for the observed linear rate of transition. (Contains 2 figures.)

  7. Rapid determination of 210Po in water samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2013-08-02

    A new rapid method for the determination of 210Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210Po in water samples have typically involved spontaneous auto-deposition of 210Po onto silver or other metal disks followed by counting by alphamore » spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210Pb analysis. A new rapid method for 210Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210Po.« less

  8. Rapid determination of 226Ra in emergency urine samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2014-02-27

    A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed.more » The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226Ra with DGA Resin, saving time. 133Ba was used instead of 225Ra as tracer to allow immediate counting; however, 225Ra can still be used as an option. The rapid purification of 226Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226Ra, with rapid removal of isobaric interferences.« less

  9. Processing and fabrication of mixed uranium/refractory metal carbide fuels with liquid-phase sintering

    NASA Astrophysics Data System (ADS)

    Knight, Travis W.; Anghaie, Samim

    2002-11-01

    Optimization of powder processing techniques were sought for the fabrication of single-phase, solid-solution mixed uranium/refractory metal carbide nuclear fuels - namely (U, Zr, Nb)C. These advanced, ultra-high temperature nuclear fuels have great potential for improved performance over graphite matrix, dispersed fuels tested in the Rover/NERVA program of the 1960s and early 1970s. Hypostoichiometric fuel samples with carbon-to-metal ratios of 0.98, uranium metal mole fractions of 5% and 10%, and porosities less than 5% were fabricated. These qualities should provide for the longest life and highest performance capability for these fuels. Study and optimization of processing methods were necessary to provide the quality assurance of samples for meaningful testing and assessment of performance for nuclear thermal propulsion applications. The processing parameters and benefits of enhanced sintering by uranium carbide liquid-phase sintering were established for the rapid and effective consolidation and formation of a solid-solution mixed carbide nuclear fuel.

  10. Rapid doubling of the critical current of YBa 2Cu 3O 7-δ coated conductors for viable high-speed industrial processing

    DOE PAGES

    Leroux, M.; Kihlstrom, K. J.; Holleis, S.; ...

    2015-11-09

    Here, we demonstrate that 3.5-MeV oxygen irradiation can markedly enhance the in-field critical current of commercial second generation superconducting tapes with an exposure time of just 1 s per 0.8 cm 2. Furthermore we demonstrate how speed is now at the level required for an industrial reel-to-reel post-processing. The irradiation is made on production line samples through the protective silver coating and does not require any modification of the growth process. From TEM imaging, we identify small clusters as the main source of increased vortex pinning.

  11. [Concordance among invasive diagnostic procedures for Helicobacter pylori infection in adults].

    PubMed

    Sánchez-Cuén, Jaime Alberto; Canizalez-Román, Vicente Adrián; León-Sicairos, Nidia Maribel; Irineo-Cabrales, Ana Bertha; Bernal-Magaña, Gregorio

    2015-01-01

    Compare the strength of concordance between culture, histology, rapid urease test for diagnosis of Helicobacter pylori infection and histopathological findings relationship and frequency of positivity among such diagnostic procedures. Diagnostic test study. The study population were subjects with endoscopy and take samples of gastric antral. Rapid urease test (one sample), histology (two samples) and culture (two samples), and histopathological findings of gastric mucosa were performed. Statistical design with Student's t, Fisher exact test, Kappa coefficient. We reviewed 108 subjects, 28 (25.9%) men, 80 (74.1%) women, mean age was 49.1 years (SD 15.1). The Kappa coefficient was 0.729 and 0.377 between culture with histology and rapid urease test, respectively; likewise the Kappa coefficient was 0.565 between histology and rapid urease test. The strength of concordance was higher between histology with culture and rapid urease test; the most recommended being histology in clinical practice for the detection of Helicobacter pylori infection.

  12. Rapid detection of MERS coronavirus-like viruses in bats: pote1ntial for tracking MERS coronavirus transmission and animal origin.

    PubMed

    Woo, Patrick C Y; Lau, Susanna K P; Chen, Yixin; Wong, Emily Y M; Chan, Kwok-Hung; Chen, Honglin; Zhang, Libiao; Xia, Ningshao; Yuen, Kwok-Yung

    2018-03-07

    Recently, we developed a monoclonal antibody-based rapid nucleocapsid protein detection assay for diagnosis of MERS coronavirus (MERS-CoV) in humans and dromedary camels. In this study, we examined the usefulness of this assay to detect other lineage C betacoronaviruses closely related to MERS-CoV in bats. The rapid MERS-CoV nucleocapsid protein detection assay was tested positive in 24 (88.9%) of 27 Tylonycteris bat CoV HKU4 (Ty-BatCoV-HKU4) RNA-positive alimentary samples of Tylonycteris pachypus and 4 (19.0%) of 21 Pipistrellus bat CoV HKU5 (Pi-BatCoV-HKU5) RNA-positive alimentary samples of Pipistrellus abramus. There was significantly more Ty-BatCoV-HKU4 RNA-positive alimentary samples than Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive by the rapid MERS-CoV nucleocapsid protein detection assay (P < 0.001 by Chi-square test). The rapid assay was tested negative in all 51 alimentary samples RNA-positive for alphacoronaviruses (Rhinolophus bat CoV HKU2, Myotis bat CoV HKU6, Miniopterus bat CoV HKU8 and Hipposideros batCoV HKU10) and 32 alimentary samples positive for lineage B (SARS-related Rhinolophus bat CoV HKU3) and lineage D (Rousettus bat CoV HKU9) betacoronaviruses. No significant difference was observed between the viral loads of Ty-BatCoV-HKU4/Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive and negative by the rapid test (Mann-Witney U test). The rapid MERS-CoV nucleocapsid protein detection assay is able to rapidly detect lineage C betacoronaviruses in bats. It detected significantly more Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5 because MERS-CoV is more closely related to Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5. This assay will facilitate rapid on-site mass screening of animal samples for ancestors of MERS-CoV and tracking transmission in the related bat species.

  13. Fast and automatic thermographic material identification for the recycling process

    NASA Astrophysics Data System (ADS)

    Haferkamp, Heinz; Burmester, Ingo

    1998-03-01

    Within the framework of the future closed loop recycling process the automatic and economical sorting of plastics is a decisive element. The at the present time available identification and sorting systems are not yet suitable for the sorting of technical plastics since essential demands, as the realization of high recognition reliability and identification rates considering the variety of technical plastics, can not be guaranteed. Therefore the Laser Zentrum Hannover e.V. in cooperation with the Hoerotron GmbH and the Preussag Noell GmbH has carried out investigations on a rapid thermographic and laser-supported material- identification-system for automatic material-sorting- systems. The automatic identification of different engineering plastics coming from electronic or automotive waste is possible. Identification rates up to 10 parts per second are allowed by the effort from fast IR line scanners. The procedure is based on the following principle: within a few milliseconds a spot on the relevant sample is heated by a CO2 laser. The samples different and specific chemical and physical material properties cause different temperature distributions on their surfaces that are measured by a fast IR-linescan system. This 'thermal impulse response' has to be analyzed by means of a computer system. Investigations have shown that it is possible to analyze more than 18 different sorts of plastics at a frequency of 10 Hz. Crucial for the development of such a system is the rapid processing of imaging data, the minimization of interferences caused by oscillating samples geometries, and a wide range of possible additives in plastics in question. One possible application area is sorting of plastics coming from car- and electronic waste recycling.

  14. Novel method for fast characterization of high-surface-area electrocatalytic materials using carbon fiber microelectrode.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strmcnik, D.; Hodnik, N.; Hocevar, S. B.

    2010-02-18

    A carbon fiber microelectrode (CFME) was used for characterization of the nanoparticle catalysts as an alternative to the well-established rotating disk electrode (RDE) method. We found that the novel CFME method yielded comparable results to the RDE method when investigating the adsorption/desorption processes as well the specific activity for reactions such as the oxygen reduction reaction. Its major advantage over the RDE method is a fast sample preparation and rapid measurement, reducing significantly the time of a single sample characterization from 2-3 h to a favorable 5-10 min.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Jesse S.; Sinogeikin, Stanislav V.; Lin, Chuanlong

    Complementary advances in high pressure research apparatus and techniques make it possible to carry out time-resolved high pressure research using what would customarily be considered static high pressure apparatus. This work specifically explores time-resolved high pressure x-ray diffraction with rapid compression and/or decompression of a sample in a diamond anvil cell. Key aspects of the synchrotron beamline and ancillary equipment are presented, including source considerations, rapid (de)compression apparatus, high frequency imaging detectors, and software suitable for processing large volumes of data. A number of examples are presented, including fast equation of state measurements, compression rate dependent synthesis of metastable statesmore » in silicon and germanium, and ultrahigh compression rates using a piezoelectric driven diamond anvil cell.« less

  16. DNA extraction for streamlined metagenomics of diverse environmental samples.

    PubMed

    Marotz, Clarisse; Amir, Amnon; Humphrey, Greg; Gaffney, James; Gogul, Grant; Knight, Rob

    2017-06-01

    A major bottleneck for metagenomic sequencing is rapid and efficient DNA extraction. Here, we compare the extraction efficiencies of three magnetic bead-based platforms (KingFisher, epMotion, and Tecan) to a standardized column-based extraction platform across a variety of sample types, including feces, oral, skin, soil, and water. Replicate sample plates were extracted and prepared for 16S rRNA gene amplicon sequencing in parallel to assess extraction bias and DNA quality. The data demonstrate that any effect of extraction method on sequencing results was small compared with the variability across samples; however, the KingFisher platform produced the largest number of high-quality reads in the shortest amount of time. Based on these results, we have identified an extraction pipeline that dramatically reduces sample processing time without sacrificing bacterial taxonomic or abundance information.

  17. A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

    NASA Astrophysics Data System (ADS)

    Yang, Kuojun; Tian, Shulin; Zeng, Hao; Qiu, Lei; Guo, Lianping

    2014-04-01

    In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

  18. A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Kuojun, E-mail: kuojunyang@gmail.com; Guo, Lianping; School of Electrical and Electronic Engineering, Nanyang Technological University

    In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, whichmore » converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.« less

  19. Rapid and quantitative detection of the microbial spoilage of meat by fourier transform infrared spectroscopy and machine learning.

    PubMed

    Ellis, David I; Broadhurst, David; Kell, Douglas B; Rowland, Jem J; Goodacre, Royston

    2002-06-01

    Fourier transform infrared (FT-IR) spectroscopy is a rapid, noninvasive technique with considerable potential for application in the food and related industries. We show here that this technique can be used directly on the surface of food to produce biochemically interpretable "fingerprints." Spoilage in meat is the result of decomposition and the formation of metabolites caused by the growth and enzymatic activity of microorganisms. FT-IR was exploited to measure biochemical changes within the meat substrate, enhancing and accelerating the detection of microbial spoilage. Chicken breasts were purchased from a national retailer, comminuted for 10 s, and left to spoil at room temperature for 24 h. Every hour, FT-IR measurements were taken directly from the meat surface using attenuated total reflectance, and the total viable counts were obtained by classical plating methods. Quantitative interpretation of FT-IR spectra was possible using partial least-squares regression and allowed accurate estimates of bacterial loads to be calculated directly from the meat surface in 60 s. Genetic programming was used to derive rules showing that at levels of 10(7) bacteria.g(-1) the main biochemical indicator of spoilage was the onset of proteolysis. Thus, using FT-IR we were able to acquire a metabolic snapshot and quantify, noninvasively, the microbial loads of food samples accurately and rapidly in 60 s, directly from the sample surface. We believe this approach will aid in the Hazard Analysis Critical Control Point process for the assessment of the microbiological safety of food at the production, processing, manufacturing, packaging, and storage levels.

  20. A study of internal structure in components made by additive manufacturing process using 3 D X-ray tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raguvarun, K., E-mail: prajagopal@iitm.ac.in; Balasubramaniam, Krishnan, E-mail: prajagopal@iitm.ac.in; Rajagopal, Prabhu, E-mail: prajagopal@iitm.ac.in

    Additive manufacturing methods are gaining increasing popularity for rapidly and efficiently manufacturing parts and components in the industrial context, as well as for domestic applications. However, except when used for prototyping or rapid visualization of components, industries are concerned with the load carrying capacity and strength achievable by additive manufactured parts. In this paper, the wire-arc additive manufacturing (AM) process based on gas tungsten arc welding (GTAW) has been examined for the internal structure and constitution of components generated by the process. High-resolution 3D X-ray tomography is used to gain cut-views through wedge-shaped parts created using this GTAW additive manufacturingmore » process with titanium alloy materials. In this work, two different control conditions for the GTAW process are considered. The studies reveal clusters of porosities, located in periodic spatial intervals along the sample cross-section. Such internal defects can have a detrimental effect on the strength of the resulting AM components, as shown in destructive testing studies. Closer examination of this phenomenon shows that defect clusters are preferentially located at GTAW traversal path intervals. These results highlight the strong need for enhanced control of process parameters in ensuring components with minimal defects and higher strength.« less

  1. A study of internal structure in components made by additive manufacturing process using 3 D X-ray tomography

    NASA Astrophysics Data System (ADS)

    Raguvarun, K.; Balasubramaniam, Krishnan; Rajagopal, Prabhu; Palanisamy, Suresh; Nagarajah, Romesh; Hoye, Nicholas; Curiri, Dominic; Kapoor, Ajay

    2015-03-01

    Additive manufacturing methods are gaining increasing popularity for rapidly and efficiently manufacturing parts and components in the industrial context, as well as for domestic applications. However, except when used for prototyping or rapid visualization of components, industries are concerned with the load carrying capacity and strength achievable by additive manufactured parts. In this paper, the wire-arc additive manufacturing (AM) process based on gas tungsten arc welding (GTAW) has been examined for the internal structure and constitution of components generated by the process. High-resolution 3D X-ray tomography is used to gain cut-views through wedge-shaped parts created using this GTAW additive manufacturing process with titanium alloy materials. In this work, two different control conditions for the GTAW process are considered. The studies reveal clusters of porosities, located in periodic spatial intervals along the sample cross-section. Such internal defects can have a detrimental effect on the strength of the resulting AM components, as shown in destructive testing studies. Closer examination of this phenomenon shows that defect clusters are preferentially located at GTAW traversal path intervals. These results highlight the strong need for enhanced control of process parameters in ensuring components with minimal defects and higher strength.

  2. Rapid determination of ampicillin in bovine milk by liquid chromatography with fluorescence detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ang, C.Y.W.; Luo, Wenhong

    1997-01-01

    A rapid and sensitive liquid chromatographic (LC) method was developed for the determination of ampicillin residues in raw bovine milk, processed skim milk, and pasteurized, homogenized whole milk with vitamin D. Milk samples were deproteinized with trichloroacetic acid (TCA) and acetonictrile. After centrifugation, the clear supernatant was reacted with formaldehyde and TCA under heat. The major fluorescent derivative of ampicillin was then determined by reversed-phase LC with fluorescence detection. Average recoveries of ampicillin fortified at 5, 10, and 20 ppb (ng/mL) were all >85% with coefficients of variation <10%. Limits of detection ranged from 0.31 to 0.51 ppb and limitsmore » of quantitation, from 0.66 to 1.2 ppb. After appropriate validation, this method should be suitable for rapid analysis of milk for ampicillin residues at the tolerance level of 10 ppb. 16 refs., 4 figs., 3 tabs.« less

  3. Rapid Authentication of Ginkgo biloba Herbal Products Using the Recombinase Polymerase Amplification Assay.

    PubMed

    Liu, Yang; Wang, Xiao-Yue; Wei, Xue-Min; Gao, Zi-Tong; Han, Jian-Ping

    2018-05-22

    Species adulteration in herbal products (HPs) exposes consumers to health risks. Chemical and morphological methods have their own deficiencies when dealing with the detection of species containing the same active compounds in HPs. In this study, we developed a rapid identification method using the recombinase polymerase amplification (RPA) assay to detect two species, Ginkgo biloba and Sophora japonica (as adulteration), in Ginkgo biloba HPs. Among 36 Ginkgo biloba HP samples, 34 were found to have Ginkgo biloba sequences, and 9 were found to have Sophora japonica sequences. During the authentication process, the RPA-LFS assay showed a higher specificity, sensitivity and efficiency than PCR-based methods. We initially applied the RPA-LSF technique to detect plant species in HPs, demonstrating that this assay can be developed into an efficient tool for the rapid on-site authentication of plant species in Ginkgo biloba HPs.

  4. Rapid Diagnostic Tests for Identifying Avian Influenza A(H7N9) Virus in Clinical Samples

    PubMed Central

    Chen, Yu; Wang, Dayan; Zheng, Shufa; Shu, Yuelong; Chen, Wenxiang; Cui, Dawei; Li, Jinming; Yu, Hongjie; Wang, Yu; Li, Lanjuan

    2015-01-01

    To determine sensitivity of rapid diagnostic tests for detecting influenza A(H7N9) virus, we compared rapid tests with PCR results and tested different types of clinical samples. Usefulness of seasonal influenza rapid tests for A(H7N9) virus infections is limited because of their low sensitivity for detecting virus in upper respiratory tract specimens. PMID:25529064

  5. Rapid screening of mixed edible oils and gutter oils by matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Ng, Tsz-Tsun; So, Pui-Kin; Zheng, Bo; Yao, Zhong-Ping

    2015-07-16

    Authentication of edible oils is a long-term issue in food safety, and becomes particularly important with the emergence and wide spread of gutter oils in recent years. Due to the very high analytical demand and diversity of gutter oils, a high throughput analytical method and a versatile strategy for authentication of mixed edible oils and gutter oils are highly desirable. In this study, an improved matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) method has been developed for direct analysis of edible oils. This method involved on-target sample loading, automatic data acquisition and simple data processing. MALDI-MS spectra with high quality and high reproducibility have been obtained using this method, and a preliminary spectral database of edible oils has been set up. The authenticity of an edible oil sample can be determined by comparing its MALDI-MS spectrum and principal component analysis (PCA) results with those of its labeled oil in the database. This method is simple and the whole process only takes several minutes for analysis of one oil sample. We demonstrated that the method was sensitive to change in oil compositions and can be used for measuring compositions of mixed oils. The capability of the method for determining mislabeling enables it for rapid screening of gutter oils since fraudulent mislabeling is a common feature of gutter oils. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Using dispersive liquid-liquid microextraction and liquid chromatography for determination of guaifenesin enantiomers in human urine.

    PubMed

    Hatami, Mehdi; Farhadi, Khalil; Abdollahpour, Assem

    2011-11-01

    A simple, rapid, and efficient method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-fluorescence detector, has been developed for the determination of guaifenesin (GUA) enantiomers in human urine samples after an oral dose administration of its syrup formulation. Urine samples were collected during the time intervals 0-2, 2-4, and 4-6 h and concentration and ratio of two enantiomers was determined. The ratio of R-(-) to S-(+) enantiomer concentrations in urine showed an increase with time, with R/S ratios of 0.66 at 2 h and 2.23 at 6 h. For microextraction process, a mixture of extraction solvent (dichloromethane, 100 μL) and dispersive solvent (THF, 1 mL) was rapidly injected into 5.0 mL diluted urine sample for the formation of cloudy solution and extraction of enantiomers into the fine droplets of CH(2)Cl(2). After optimization of HPLC enantioselective conditions, some important parameters, such as the kind and volume of extraction and dispersive solvents, extraction time, temperature, pH, and salt effect were optimized for dispersive liquid-liquid microextraction process. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 10 to 2000 ng/mL for target analytes. LOD was 3.00 ng/mL for both of the enantiomers. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Comparison of reverse transcriptase PCR, reverse transcriptase loop-mediated isothermal amplification, and culture-based assays for Salmonella detection from pork processing environments.

    PubMed

    Techathuvanan, Chayapa; Draughon, Frances Ann; D'Souza, Doris Helen

    2011-02-01

    Novel rapid Salmonella detection assays without the need for sophisticated equipment or labor remain in high demand. Real-time reverse transcriptase PCR (RT-PCR) assays, though rapid and sensitive, require expensive thermocyclers, while a novel RT loop-mediated isothermal amplification (RT-LAMP) method requires only a simple water bath. Our objective was to compare the detection sensitivity of Salmonella Typhimurium from the pork processing environment by RT-LAMP, RT-PCR, and culture-based assays. Carcass and surface swabs and carcass rinses were obtained from a local processing plant. Autoclaved carcass rinses (500 ml) were spiked with Salmonella Typhimurium and filtered. Filters were placed in stomacher bags containing tetrathionate broth (TTB) and analyzed with or without 10-h enrichment at 37 °C. Natural swabs were stomached with buffered peptone water, and natural carcass rinses were filtered, preenriched, and further enriched in TTB. Serially-diluted enriched samples were enumerated by spread plating on xylose lysine Tergitol 4 agar. RNA was extracted from 5 ml of enriched TTB with TRIzol. RT-LAMP assay using previously described invA primers was conducted at 62 °C for 90 min in a water bath with visual detection and by gel electrophoresis. SYBR Green I-based-real-time RT-PCR was carried out with invA primers followed by melt temperature analysis. The results of RT-LAMP detection for spiked carcass rinses were comparable to those of RT-PCR and cultural plating, with detection limits of 1 log CFU/ml, although they were obtained significantly faster, within 24 h including preenrichment and enrichment. RT-LAMP showed 4 of 12 rinse samples positive, while RT-PCR showed 1 of 12 rinse samples positive. For swabs, 6 of 27 samples positive by RT-LAMP and 5 of 27 by RT-PCR were obtained. This 1-day RT-LAMP assay shows promise for routine Salmonella screening by the pork industry. Copyright ©, International Association for Food Protection

  8. NASA's Genesis and Rapid Intensification Processes (GRIP) Field Experiment

    NASA Technical Reports Server (NTRS)

    Braun, Scott A.; Kakar, Ramesh; Zipser, Edward; Heymsfield, Gerald; Albers, Cerese; Brown, Shannon; Durden, Stephen; Guimond, Stephen; Halverson, Jeffery; Heymsfield, Andrew; hide

    2013-01-01

    In August–September 2010, NASA, NOAA, and the National Science Foundation (NSF) conducted separate but closely coordinated hurricane field campaigns, bringing to bear a combined seven aircraft with both new and mature observing technologies. NASA's Genesis and Rapid Intensification Processes (GRIP) experiment, the subject of this article, along with NOAA's Intensity Forecasting Experiment (IFEX) and NSF's Pre-Depression Investigation of Cloud-Systems in the Tropics (PREDICT) experiment, obtained unprecedented observations of the formation and intensification of tropical cyclones. The major goal of GRIP was to better understand the physical processes that control hurricane formation and intensity change, specifically the relative roles of environmental and inner-core processes. A key focus of GRIP was the application of new technologies to address this important scientific goal, including the first ever use of the unmanned Global Hawk aircraft for hurricane science operations. NASA and NOAA conducted coordinated flights to thoroughly sample the rapid intensification (RI) of Hurricanes Earl and Karl. The tri-agency aircraft teamed up to perform coordinated flights for the genesis of Hurricane Karl and Tropical Storm Matthew and the non-redevelopment of the remnants of Tropical Storm Gaston. The combined GRIP–IFEX–PREDICT datasets, along with remote sensing data from a variety of satellite platforms [Geostationary Operational Environmental Satellite (GOES), Tropical Rainfall Measuring Mission (TRMM), Aqua, Terra, CloudSat, and Cloud–Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO)], will contribute to advancing understanding of hurricane formation and intensification. This article summarizes the GRIP experiment, the missions flown, and some preliminary findings.

  9. Powder-Metallurgy Process And Product

    NASA Technical Reports Server (NTRS)

    Paris, Henry G.

    1988-01-01

    Rapid-solidification processing yields alloys with improved properties. Study undertaken to extend favorable property combinations of I/M 2XXX alloys through recently developed technique of rapid-solidification processing using powder metallurgy(P/M). Rapid-solidification processing involves impingement of molten metal stream onto rapidly-spinning chill block or through gas medium using gas atomization technique.

  10. An Open-Source Storage Solution for Cryo-Electron Microscopy Samples.

    PubMed

    Ultee, Eveline; Schenkel, Fred; Yang, Wen; Brenzinger, Susanne; Depelteau, Jamie S; Briegel, Ariane

    2018-02-01

    Cryo-electron microscopy (cryo-EM) enables the study of biological structures in situ in great detail and to solve protein structures at Ångstrom level resolution. Due to recent advances in instrumentation and data processing, the field of cryo-EM is a rapidly growing. Access to facilities and national centers that house the state-of-the-art microscopes is limited due to the ever-rising demand, resulting in long wait times between sample preparation and data acquisition. To improve sample storage, we have developed a cryo-storage system with an efficient, high storage capacity that enables sample storage in a highly organized manner. This system is simple to use, cost-effective and easily adaptable for any type of grid storage box and dewar and any size cryo-EM laboratory.

  11. High throughput wafer defect monitor for integrated metrology applications in photolithography

    NASA Astrophysics Data System (ADS)

    Rao, Nagaraja; Kinney, Patrick; Gupta, Anand

    2008-03-01

    The traditional approach to semiconductor wafer inspection is based on the use of stand-alone metrology tools, which while highly sensitive, are large, expensive and slow, requiring inspection to be performed off-line and on a lot sampling basis. Due to the long cycle times and sparse sampling, the current wafer inspection approach is not suited to rapid detection of process excursions that affect yield. The semiconductor industry is gradually moving towards deploying integrated metrology tools for real-time "monitoring" of product wafers during the manufacturing process. Integrated metrology aims to provide end-users with rapid feedback of problems during the manufacturing process, and the benefit of increased yield, and reduced rework and scrap. The approach of monitoring 100% of the wafers being processed requires some trade-off in sensitivity compared to traditional standalone metrology tools, but not by much. This paper describes a compact, low-cost wafer defect monitor suitable for integrated metrology applications and capable of detecting submicron defects on semiconductor wafers at an inspection rate of about 10 seconds per wafer (or 360 wafers per hour). The wafer monitor uses a whole wafer imaging approach to detect defects on both un-patterned and patterned wafers. Laboratory tests with a prototype system have demonstrated sensitivity down to 0.3 µm on un-patterned wafers and down to 1 µm on patterned wafers, at inspection rates of 10 seconds per wafer. An ideal application for this technology is preventing photolithography defects such as "hot spots" by implementing a wafer backside monitoring step prior to exposing wafers in the lithography step.

  12. Optical Processing Techniques For Pseudorandom Sequence Prediction

    NASA Astrophysics Data System (ADS)

    Gustafson, Steven C.

    1983-11-01

    Pseudorandom sequences are series of apparently random numbers generated, for example, by linear or nonlinear feedback shift registers. An important application of these sequences is in spread spectrum communication systems, in which, for example, the transmitted carrier phase is digitally modulated rapidly and pseudorandomly and in which the information to be transmitted is incorporated as a slow modulation in the pseudorandom sequence. In this case the transmitted information can be extracted only by a receiver that uses for demodulation the same pseudorandom sequence used by the transmitter, and thus this type of communication system has a very high immunity to third-party interference. However, if a third party can predict in real time the probable future course of the transmitted pseudorandom sequence given past samples of this sequence, then interference immunity can be significantly reduced.. In this application effective pseudorandom sequence prediction techniques should be (1) applicable in real time to rapid (e.g., megahertz) sequence generation rates, (2) applicable to both linear and nonlinear pseudorandom sequence generation processes, and (3) applicable to error-prone past sequence samples of limited number and continuity. Certain optical processing techniques that may meet these requirements are discussed in this paper. In particular, techniques based on incoherent optical processors that perform general linear transforms or (more specifically) matrix-vector multiplications are considered. Computer simulation examples are presented which indicate that significant prediction accuracy can be obtained using these transforms for simple pseudorandom sequences. However, the useful prediction of more complex pseudorandom sequences will probably require the application of more sophisticated optical processing techniques.

  13. Tenderness classification of beef: II. Design and analysis of a system to measure beef longissimus shear force under commercial processing conditions.

    PubMed

    Shackelford, S D; Wheeler, T L; Koohmaraie, M

    1999-06-01

    The objectives of this study were to evaluate the efficacy of a system for classifying beef for tenderness based on a rapid, simple method of measuring cooked longissimus shear force. Longissimus steaks (2.54 cm thick) were trimmed free of s.c. fat and bone and rapidly cooked using a belt grill. A 1-cm-thick, 5-cm-long slice was removed from the cooked longissimus parallel with the muscle fibers for measurement of shear force. Slices were sheared with a flat, blunt-end blade using an electronic testing machine. The entire process was completed in less than 10 min. Therefore, in commercial application, this process could be completed during the 10- to 15-min period that carcasses are normally held to allow the ribeye to bloom for quality grading. In Exp. 1, the repeatability of slice shear force (SSF), as determined by evaluation of duplicate samples from 204 A-maturity carcasses, was .89. In Exp. 2, A-maturity carcasses (n = 483) were classified into three groups based on SSF (< 23, 23 to 40, and > 40 kg) at 3 d postmortem that differed (P < .001) in mean trained sensory panel tenderness ratings (7.3 +/- .04, 6.4 +/- .06, and 4.4 +/- .20) and the percentages (100, 91, and 28%) of samples rated "Slightly Tender" or higher at 14 d postmortem. Therefore, this tenderness classification system could be used to accurately segregate beef carcasses into expected tenderness groups. Further research is needed to test the feasibility and accuracy of this system under a variety of commercial processing conditions.

  14. Development and evaluation of a collection apparatus for recoil products for study of the deexcitation process of (235m)U.

    PubMed

    Shigekawa, Y; Kasamatsu, Y; Shinohara, A

    2016-05-01

    The nucleus (235m)U is an isomer with extremely low excitation energy (76.8 eV) and decays dominantly through the internal conversion (IC) process. Because outer-shell electrons are involved in the IC process, the decay constant of (235m)U depends on its chemical environment. We plan to study the deexcitation process of (235m)U by measuring the energy spectra of IC electrons in addition to the decay constants for various chemical forms. In this paper, the preparation method of (235m)U samples from (239)Pu by using alpha-recoil energy is reported. A Collection Apparatus for Recoil Products was fabricated, and then collection efficiencies under various conditions were determined by collecting (224)Ra recoiling out of (228)Th electrodeposited and precipitated sources. The pressure in the apparatus (vacuum or 1 atm of N2 gas) affected the variations of the collection efficiencies depending on the negative voltage applied to the collector. The maximum values of the collection efficiencies were mainly affected by the thickness of the (228)Th sources. From these results, the suitable conditions of the (239)Pu sources for preparation of (235m)U were determined. In addition, dissolution efficiencies were determined by washing collected (224)Ra with solutions. When (224)Ra was collected in 1 atm of N2 gas and dissolved with polar solutions such as water, the dissolution efficiencies were nearly 100%. The method of rapid dissolution of recoil products would be applicable to rapid preparation of short-lived (235m)U samples for various chemical forms.

  15. Rapid determination of caffeine in one drop of beverages and foods using drop-to-drop solvent microextraction with gas chromatography/mass spectrometry.

    PubMed

    Shrivas, Kamlesh; Wu, Hui-Fen

    2007-11-02

    A simple and rapid sample cleanup and preconcentration method for the quantitative determination of caffeine in one drop of beverages and foods by gas chromatography/mass spectrometry (GC/MS) has been proposed using drop-to-drop solvent microextraction (DDSME). The best optimum experimental conditions for DDSME were: chloroform as the extraction solvent, 5 min extraction time, 0.5 microL exposure volume of the extraction phase and no salt addition at room temperature. The optimized methodology exhibited good linearity between 0.05 and 5.0 microg/mL with correlation coefficient of 0.980. The relative standard deviation (RSD) and limits of detection (LOD) of the DDSME/GC/MS method were 4.4% and 4.0 ng/mL, respectively. Relative recovery of caffeine in beverages and foods were found to be 96.6-101%, which showing good reliability of this method. This DDSME excludes the major disadvantages of conventional method of caffeine extraction, like large amount of organic solvent and sample consumption and long sample pre-treatment process. So, this approach proves that the DDSME/GC/MS technique can be applied as a simple, fast and feasible diagnosis tool for environmental, food and biological application for extremely small amount of real sample analysis.

  16. Development of a micropulverized extraction method for rapid toxicological analysis of methamphetamine in hair.

    PubMed

    Miyaguchi, Hajime; Kakuta, Masaya; Iwata, Yuko T; Matsuda, Hideaki; Tazawa, Hidekatsu; Kimura, Hiroko; Inoue, Hiroyuki

    2007-09-07

    We developed a rapid sample preparation method for the toxicological analysis of methamphetamine and amphetamine (the major metabolite of methamphetamine) in human hair by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), to facilitate fast screening and quantitation. Two milligrams of hair were mechanically micropulverized for 5 min in a 2-ml plastic tube together with 100 microl of an aqueous solvent containing 10% acetonitrile, 100 mM trifluoroacetic acid and the corresponding deuterium analogues as internal standards. The pulverizing highly disintegrated the hair components, simultaneously allowing the extraction of any drugs present in the hair. After filtering the suspension with a membrane-filter unit, the clear filtrate was directly analyzed by HPLC-MS/MS. No evaporation processes were required for sample preparation. Method optimization and validation study were carried out using real-case specimens and fortified samples in which the drugs had been artificially absorbed, respectively. Concentration ranges for quantitation were 0.040-125 and 0.040-25 ng/mg for methamphetamine and amphetamine, respectively. Real-case specimens were analyzed by the method presented here and by conventional ones to verify the applicability of our method to real-world analysis. Our method took less than 30 min for a set of chromatograms to be obtained from a washed hair sample.

  17. A rapid assay for the simultaneous determination of nicotine, cocaine and metabolites in meconium using disposable pipette extraction and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Mozaner Bordin, Dayanne C; Alves, Marcela N R; Cabrices, Oscar G; de Campos, Eduardo G; De Martinis, Bruno Spinosa

    2014-01-01

    Drug abuse by pregnant women is considered a serious public health problem worldwide. Meconium is the first excretion in newborns and has been used as an alternative matrix to evaluate in utero drug exposure. Solid phase extraction (SPE) is widely employed to prepare and clean up samples in the field of forensic analysis. Most SPE products require large volumes of solvent, which culminates in longer sample processing times and increased cost per sample. Disposable pipette extraction (DPX) tips have been used as an alternative to traditional SPE cartridges. They combine efficient and rapid extraction with reduced solvent consumption. The purpose of this study was to develop and validate a method to determine nicotine, cotinine, cocaine, benzoylecgonine, cocaethylene and methyl ester anhydroecgonine in meconium using DPX and gas chromatography-mass spectrometry (GC-MS). Validation results indicated that extraction efficiency ranged 50-98%, accuracy 92-106%, intra-assay precision 4-12% and inter-assay precision 6-12%. Linear calibration curves resulted in R(2) values >0.99, limits of detection ranged from 2.5 to 15 ng/g and the limit of quantitation from 10 to 20 ng/g. The DPX-GC-MS method was shown to selectively analyze trace concentrations of drugs in meconium samples. Finally, the developed and validated method was applied to 50 meconium samples.

  18. Microfluidic paper-based analytical device for particulate metals.

    PubMed

    Mentele, Mallory M; Cunningham, Josephine; Koehler, Kirsten; Volckens, John; Henry, Charles S

    2012-05-15

    A microfluidic paper-based analytical device (μPAD) fabricated by wax printing was designed to assess occupational exposure to metal-containing aerosols. This method employs rapid digestion of particulate metals using microliters of acid added directly to a punch taken from an air sampling filter. Punches were then placed on a μPAD, and digested metals were transported to detection reservoirs upon addition of water. These reservoirs contained reagents for colorimetric detection of Fe, Cu, and Ni. Dried buffer components were used to set the optimal pH in each detection reservoir, while precomplexation agents were deposited in the channels between the sample and detection zones to minimize interferences from competing metals. Metal concentrations were quantified from color intensity images using a scanner in conjunction with image processing software. Reproducible, log-linear calibration curves were generated for each metal, with method detection limits ranging from 1.0 to 1.5 μg for each metal (i.e., total mass present on the μPAD). Finally, a standard incineration ash sample was aerosolized, collected on filters, and analyzed for the three metals of interest. Analysis of this collected aerosol sample using a μPAD showed good correlation with known amounts of the metals present in the sample. This technology can provide rapid assessment of particulate metal concentrations at or below current regulatory limits and at dramatically reduced cost.

  19. Innovation leading the way: application of lean manufacturing to sample management.

    PubMed

    Allen, M; Wigglesworth, M J

    2009-06-01

    Historically, sample management successfully focused on providing compound quality and tracking distribution within a diverse geographic. However, if a competitive advantage is to be delivered in a changing environment of outsourcing, efficiency and customer service must now improve or face reconstruction. The authors have used discrete event simulation to model the compound process from chemistry to assay and applied lean manufacturing techniques to analyze and improve these processes. In doing so, they identified a value-adding process time of just 11 min within a procedure that took days. Modeling also allowed the analysis of equipment and human resources necessary to complete the expected demand in an acceptable cycle time. Layout and location of sample management and screening departments are key in allowing process integration, creating rapid flow of work, and delivering these efficiencies. Following this analysis and minor process changes, the authors have demonstrated for 2 programs that solid compounds can be converted to assay-ready plates in less than 4 h. In addition, it is now possible to deliver assay data from these compounds within the same working day, allowing chemistry teams more flexibility and more time to execute the next chemistry round. Additional application of lean manufacturing principles has the potential to further decrease cycle times while using fewer resources.

  20. Direct analysis of samples under ambient condition by high-voltage-assisted laser desorption ionization mass spectrometry in both positive and negative ion mode.

    PubMed

    Ren, Xinxin; Liu, Jia; Zhang, Chengsen; Luo, Hai

    2013-03-15

    With the rapid development of ambient mass spectrometry, the hybrid laser-based ambient ionization methods which can generate multiply charged ions of large biomolecules and also characterize small molecules with good signal-to-noise in both positive and negative ion modes are of particular interest. An ambient ionization method termed high-voltage-assisted laser desorption ionization (HALDI) is developed, in which a 1064 nm laser is used to desorb various liquid samples from the sample target biased at a high potential without the need for an organic matrix. The pre-charged liquid samples are desorbed by the laser to form small charged droplets which may undergo an electrospray-like ionization process to produce multiply charged ions of large biomolecules. Various samples including proteins, oligonucleotides (ODNs), drugs, whole milk and chicken eggs have been analyzed by HALDI-MS in both positive and negative ion mode with little or no sample preparation. In addition, HALDI can generate intense signals with better signal-to-noise in negative ion mode than laser desorption spay post-ionization (LDSPI) from the same samples, such as ODNs and some carboxylic-group-containing small drug molecules. HALDI-MS can directly analyze a variety of liquid samples including proteins, ODNs, pharmaceuticals and biological fluids in both positive and negative ion mode without the use of an organic matrix. This technique may be further developed into a useful tool for rapid analysis in many different fields such as pharmaceutical, food, and biological sciences. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Paleointensity results for 0 and 4 ka from Hawaiian lava flows: a new approach to sampling

    NASA Astrophysics Data System (ADS)

    Cromwell, G.; Tauxe, L.; Staudigel, H.; Ron, H.; Trusdell, F.

    2012-04-01

    Paleointensity data are typically generated from core samples drilled out of the massive parts of lava flows. During Thellier-Thellier type experiments, these massive samples suffer from very low success rates (~20%), as shown by failure to meet statistical criteria. Low success generally occurs for two reasons: 1) alteration of the sample during the heating process, and 2) multi-domain behavior of massive material. Moreover, recent studies of historical lava flows show that massive samples may not accurately reflect the intensity of the magnetic field even when they are successful (Valet et al., 2010). Alternatively, submarine basaltic glasses (SBG) produce high success rates (~80%) for Thellier-Thellier type experiments, likely due to near instantaneous cooling rates which produce single-domain magnetic grains. In addition, SBG have been proven to produce accurate records of the magnetic field (e.g., Pick and Tauxe, 1993). In this study we investigate the success of paleointensity experiments on subaerial quenched basalts from Hawaii in the quest for single domain, rapidly cooled subaerial analogs to SBG. We also examine the effects of grain size and cooling rate on the accuracy of paleointensity results. During March 2011, we collected samples from 31 dated lava flows (0-3800 BP), including the historical 1950 C.E. and 2010 C.E. flows. Each lava flow was additionally subsampled when unique cooling structures within the unit could be identified. Single-domain, rapidly quenched glasses from the 1950 and 2010 flows are ideally behaved, i.e. straight Arai plots, and accurately record the expected geomagnetic field strength. However, slower cooled specimens from the same flows produce sagged Arai plots and consistently underestimate expected geomagnetic field intensity. Results from ideally behaved glasses over the last 4 ka indicate periods of rapid field change in Hawaii and a possible high intensity field spike around 2.7 ka. We will present new results from our comprehensive data set of Hawaii paleointensity on about the last 4 ka.

  2. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    PubMed

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or <250 cells/mm or an AIDS-defining illness (delayed ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  3. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    PubMed

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  4. Simultaneous and rapid determination of multiple component concentrations in a Kraft liquor process stream

    DOEpatents

    Li, Jian [Marietta, GA; Chai, Xin Sheng [Atlanta, GA; Zhu, Junyoung [Marietta, GA

    2008-06-24

    The present invention is a rapid method of determining the concentration of the major components in a chemical stream. The present invention is also a simple, low cost, device of determining the in-situ concentration of the major components in a chemical stream. In particular, the present invention provides a useful method for simultaneously determining the concentrations of sodium hydroxide, sodium sulfide and sodium carbonate in aqueous kraft pulping liquors through use of an attenuated total reflectance (ATR) tunnel flow cell or optical probe capable of producing a ultraviolet absorbency spectrum over a wavelength of 190 to 300 nm. In addition, the present invention eliminates the need for manual sampling and dilution previously required to generate analyzable samples. The inventive method can be used in Kraft pulping operations to control white liquor causticizing efficiency, sulfate reduction efficiency in green liquor, oxidation efficiency for oxidized white liquor and the active and effective alkali charge to kraft pulping operations.

  5. [Rapid analysis of metronidazole tablets by optic-fiber sensing technologies and the similarity of ultraviolet spectra].

    PubMed

    Jin, Lu; Li, Li; Li, Xin-xia; Yang, Ting; Kong, Bin; Xu, Ping-ping

    2011-02-01

    The paper is to report the development of an optic-fiber sensing technology method to analyze metronidazole tablets rapidly. In this fiber-optic sensing system, the light from source delivering to probe can be dipped into simple-handling sample solution, absorbed by the solution and reflected to the fiber-optic and detected in the detection system at last. Then the drug content can be shown in the screen from the ultraviolet absorption spectra and the consistency between that obtained by this method and that in China Pharmacopoeia can be compared. With regard to data processing, a new method is explored to identify the authenticity of drugs using the similarity between the sample map and the standard pattern by full ultraviolet spectrum. The results indicate that ultraviolet spectra of tablets can be obtained from this technology and the determination results showed no significant difference as compared with the method in China Pharmacopoeia (P > 0.05), and the similarity can be a parameter to identify the authenticity of drugs.

  6. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, C.; Dietz, M.; Kaminski, M.

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less

  7. [Comparison of two methods for rapid determination of C-reactive protein with the Tina-quant].

    PubMed

    Oremek, G M; Luksaite, R; Bretschneider, I

    2008-03-01

    C-reactive protein (CRP) as an acute phase protein is an important diagnostic marker for the presence and course of human processes. Out of the acute phase proteins it is one of those the concentrations increase most rapidly with its sensitivity being superior to other markers of inflammation, such as leukocytosis, erythrocytic sedimentation rate, and fever. This study compared two-point-of-care assays with the standard laboratory method Tina-quant CRP processed on a Hitachi 917: the immunofiltration assay NycoCard CRP Whole Blood and the turbidimetric immunoassay Micros CRP. Both methods are carried in the presence of a patient, by using capillary or venous blood. Seventy-eight blood samples were analyzed first in the standard laboratory routine and then by both rapid test assays. The precision of both assays was determined from the confidence interval. The results were statistically analyzed by arithmetic standard deviation mean method, variation coefficient, Spearman correlation index, Wilcoxon and Bland-Altman tests, and Passing-Bablock regression. NycoCard CRP Whole Blood showed a correlation coefficient of R = 0.9838; the precision had a coefficient of variation of CV = 1.8759% while As compared with Tina-quant CRP had R = 0.9934 and CV = 0.9160%. Both assays indicated the same results as Tina-quant CRP. Both Tina-quant CRP and NycoCard CRP Whole Blood give the best fit for the rapid determination of CRP.

  8. Effects of fracture and crack healing in sI methane and sII methane-ethane gas hydrate

    NASA Astrophysics Data System (ADS)

    Helgerud, M. B.; Waite, W. F.; Stern, L. A.; Kirby, S. H.

    2005-12-01

    Cracking within gas hydrate-bearing sediment can occur in the field at core-scales, due to unloading as material is brought to the surface during conventional coring, and at reservoir scales if the formation is fractured prior to production. Cracking can weaken hydrate-bearing sediment, but can also provide additional surface area for dissociation and permeability pathways for enhanced gas and fluid flow. In pulse-transmission wave speed measurements, we observe cracking in laboratory-formed pure sI methane and sII methane-ethane hydrates when samples are axially unloaded while being held under gas pressure to maintain hydrate stability. Cracking events are inferred from repeated, sharp decreases in shear wave speed occurring concurrently with abrupt increases in sample length. We also visually observe cracks in the solid samples after their recovery from the apparatus following each experiment. Following a cracking event, we observe evidence of rapid crack healing, or annealing expressed as nearly complete recovery of the shear wave speed within approximately 20 minutes. Gas hydrate recrystallization, grain growth, and annealing have also been observed in optical cell experiments and SEM imagery over a similar time frame. In a recovered hydrate-bearing core that is repressurized for storage or experimentation, rapid crack healing and recrystallization can partly restore lost mechanical strength and raise wave speeds. In a fractured portion of a hydrate-bearing reservoir, the rapid healing process can close permeable cracks and reduce the surface area available for dissociation.

  9. Fast and efficient detection of tuberculosis antigens using liposome encapsulated secretory proteins of Mycobacterium tuberculosis.

    PubMed

    Tiwari, Dileep; Haque, Shafiul; Tiwari, Ram P; Jawed, Arshad; Govender, Thavendran; Kruger, Hendrik G

    2017-04-01

    A rapid and efficient diagnostic test was developed for the detection of Mycobacterium tuberculosis antigens in serum samples of active tuberculosis (TB) and extrapulmonary TB patients via a liposomal agglutination-based method. A rapid card test has been developed to facilitate the recognition of high-affinity binding rabbit raised purified culture filtrate protein antibodies coupled on the surface of activated liposomal preparation. In the presence of TB antigens, the polyclonal antibodies bound to the liposomal particles demonstrate a visible agglutination reaction. The developed assay was simple, rapid, reliable, sensitive, and specific as a diagnostic test for the detection of antigens in serum samples of clinically confirmed cases of TB within 4-5 minutes' duration. The test was evaluated at different hospitals, medical colleges, and pathology centers, and involved 1483 participants. This investigation was conducted to detect the presence of these antigens during the period of active growth of the microorganism in serum samples for pulmonary TB and processed tissue biopsy for other extrapulmonary TB. Results obtained using this test were compared with acid-fast bacilli smear and culture results. Our study demonstrated that the newly developed liposome tuberculosis antigen card test detected antigens in our study population with approximately 97.48% sensitivity and 95.79% specificity. This is the first study to report the liposomal encapsulation of culture filtrate proteins from M. tuberculosis for diagnostic application. Copyright © 2015. Published by Elsevier B.V.

  10. Internal validation of the DNAscan/ANDE™ Rapid DNA Analysis™ platform and its associated PowerPlex® 16 high content DNA biochip cassette for use as an expert system with reference buccal swabs.

    PubMed

    Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F

    2017-07-01

    Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.

  11. An approach for evaluating the repeatability of rapid wetland assessment methods: The effects of training and experience

    EPA Science Inventory

    We sampled 92 wetlands from four different basins in the United States to quantify observer repeatability in rapid wetland condition assessment using the Delaware Rapid Assessment Protocol (DERAP). In the Inland Bays basin of Delaware, 58 wetland sites were sampled by multiple ob...

  12. Beyond Initial Encoding: Measures of the Post-Encoding Status of Memory Traces Predict Long-Term Recall during Infancy

    ERIC Educational Resources Information Center

    Pathman, Thanujeni; Bauer, Patricia J.

    2013-01-01

    The first years of life are witness to rapid changes in long-term recall ability. In the current research we contributed to an explanation of the changes by testing the absolute and relative contributions to long-term recall of encoding and post-encoding processes. Using elicited imitation, we sampled the status of 16-, 20-, and 24-month-old…

  13. Volcanic glasses, their origins and alteration processes

    USGS Publications Warehouse

    Friedman, I.; Long, W.

    1984-01-01

    Natural glass can be formed by volcanic processes, lightning (fulgarites) burning coal, and by meteorite impact. By far the most common process is volcanic - basically the glass is rapidly chilled molten rock. All natural glasses are thermodynamically unstable and tend to alter chemically or to crystallize. The rate of these processes is determined by the chemical composition of the magma. The hot and fluid basaltic melts have a structure that allows for rapid crystal growth, and seldom forms glass selvages greater than a few centimeters thick, even when the melt is rapidly cooled by extrusion in the deep sea. In contrast the cooler and very viscous rhyolitic magmas can yield bodies of glass that are tens of meters thick. These highly polymerized magmas have a high silica content - often 71-77% SiO2. Their high viscosity inhibits diffusive crystal growth. Basalt glass in sea water forms an alteration zone called palagonite whose thickness increases linearly with time. The rate of diffusion of water into rhyolitic glass, which follows the relationship - thickness = k (time) 1 2, has been determined as a function of the glass composition and temperature. Increased SiO2 increases the rate, whereas increased CaO, MgO and H2O decrease the rate. The activation energy of water diffusion varies from about 19 to 22 kcal/mol. for the glasses studied. The diffusion of alkali out of rhyolite glass occurs simultaneously with water diffusion into the glass. The rate of devitrification of rhyolitic glass is a function of the glass viscosity, which in turn is a function of water content and temperature. Although all of the aforementioned processes tend to destroy natural glasses, the slow rates of these processes, particularly for rhyolitic glass, has allowed samples of glass to persist for 60 million years. ?? 1984.

  14. A Facile CD Protocol for Rapid Determination of Enantiomeric Excess and Concentration of Chiral Primary Amines

    PubMed Central

    Nieto, Sonia; Dragna, Justin M.; Anslyn, Eric V.

    2010-01-01

    A protocol for the rapid determination of the absolute configuration and enantiomeric excess of α-chiral primary amines with potential applications in asymmetric reaction discovery has been developed. The protocol requires derivatization of α-chiral primary amines via condensation with pyridine carboxaldehyde to quantitatively yield the corresponding imine. The Cu(I) complex with 2,2'-bis (diphenylphosphino)-1,1'-dinaphthyl (BINAP -CuI) with the imine yields a metal-to-ligand-charge-transfer band (MLCT) in the visible region of the circular dichroism spectrum upon binding. Diastereomeric host-guest complexes give CD signals of the same signs, but different amplitudes, allowing for differentiation of enantiomers. Processing the primary optical data from the CD spectrum with linear discriminant analysis (LDA) allows for the determination of absolute configuration and identification of the amines, and processing with a supervised multi-layer perceptron artifical neural network (MLP-ANN) allows for the simultaneous determination of ee and concentration. The primary optical data necessary to determine the ee of unknown samples is obtained in 2 minutes per sample. To demonstrate the utility of the protocol in asymmetric reaction discovery, the ee's and concentrations for an asymmetric metal catalyzed reaction are determined. The potential of the protocol's application in high-throughput screening (HTS) of ee is discussed. PMID:19946914

  15. The electronic nose as a rapid sensor for volatile compounds in treated domestic wastewater.

    PubMed

    Dewettinck, T; Van Hege, K; Verstraete, W

    2001-07-01

    An electronic nose consisting of 12 metal oxide sensors was used to monitor volatile compounds in effluent of a domestic wastewater treatment plant. Effluent and reference (deionized water) samples were heated to 60 and 90 degrees C to promote the volatilization and to increase the sensitivity. An effluent measuring campaign of 12 weeks was conducted and the repeatability and reproducibility of the procedure and the apparatus were determined. Processing the obtained fingerprints with principal component analysis (PCA) allowed interpretation and differentiation of the samples in terms of origin and quality, relative to the reference. To minimize the variance due to sensitivity fluctuations of the apparatus and to detect effluents with deviating qualities, two new concepts were defined, i.e. the relative sensorial odour perception (in short: rSOP) and the relative fingerprint. Correlations between the relative overall electronic nose output, expressed as rSOP, and selected routine parameters were weak except for the parameter "volatile suspended solids" (VSS), indicating adsorption of volatile organic compounds (VOCs) onto the organic particles. The results clearly demonstrate the possibility to use the electronic nose as a rapid alarm generator towards volatile compounds, e.g. in specific advanced treatment processes to produce reclaimed water from effluent of the domestic wastewater treatment plant under scrutiny.

  16. Epigenetic signatures of invasive status in populations of marine invertebrates

    NASA Astrophysics Data System (ADS)

    Ardura, Alba; Zaiko, Anastasija; Morán, Paloma; Planes, Serge; Garcia-Vazquez, Eva

    2017-02-01

    Epigenetics, as a DNA signature that affects gene expression and enables rapid reaction of an organism to environmental changes, is likely involved in the process of biological invasions. DNA methylation is an epigenetic mechanism common to plants and animals for regulating gene expression. In this study we show, for the first time in any marine species, significant reduction of global methylation levels during the expansive phase of a pygmy mussel (Xenostrobus securis) recent invasion in Europe (two-year old), while in older introductions such epigenetic signature of invasion was progressively reduced. Decreased methylation was interpreted as a rapid way of increasing phenotypic plasticity that would help invasive populations to thrive. This epigenetic signature of early invasion was stronger than the expected environmental signature of environmental stress in younger populations sampled from ports, otherwise detected in a much older population (>90 year old) of the also invasive tubeworm Ficopomatus enigmaticus established in similar locations. Higher epigenetic than genetic diversity found in X. securis was confirmed from F. enigmaticus samples. As reported for introduced plants and vertebrates, epigenetic variation could compensate for relatively lower genetic variation caused by founder effects. These phenomena were compared with epigenetic mechanisms involved in metastasis, as parallel processes of community (biological invasion) and organism (cancer) invasions.

  17. An Accelerated Analytical Process for the Development of STR Profiles for Casework Samples.

    PubMed

    Laurin, Nancy; Frégeau, Chantal J

    2015-07-01

    Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single-source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30-min lysis step, a 27-min DNA extraction using the Promega Maxwell(®) 16 System, DNA quantification in <1 h using the Qiagen Investigator(®) Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpFℓSTR(®) Identifiler(®), and analysis of the profiles on the 3500-series Genetic Analyzer. This combination of fast individual steps produces high-quality profiling results and offers a cost-effective alternative approach to rapid DNA analysis. © 2015 American Academy of Forensic Sciences.

  18. Cation distributions on rapidly solidified cobalt ferrite

    NASA Technical Reports Server (NTRS)

    De Guire, Mark R.; Kalonji, Gretchen; O'Handley, Robert C.

    1990-01-01

    The cation distributions in two rapidly solidified cobalt ferrites have been determined using Moessbauer spectroscopy at 4.2 K in an 8-T magnetic field. The samples were obtained by gas atomization of a Co0-Fe2O3-P2O5 melt. The degree of cation disorder in both cases was greater than is obtainable by cooling unmelted cobalt ferrite. The more rapidly cooled sample exhibited a smaller departure from the equilibrium cation distribution than did the more slowly cooled sample. This result is explained on the basis of two competing effects of rapid solidification: high cooling rate of the solid, and large undercooling.

  19. Disposable collection kit for rapid and reliable collection of saliva.

    PubMed

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  20. Metabolomic fingerprinting employing DART-TOFMS for authentication of tomatoes and peppers from organic and conventional farming.

    PubMed

    Novotná, H; Kmiecik, O; Gałązka, M; Krtková, V; Hurajová, A; Schulzová, V; Hallmann, E; Rembiałkowska, E; Hajšlová, J

    2012-01-01

    The rapidly growing demand for organic food requires the availability of analytical tools enabling their authentication. Recently, metabolomic fingerprinting/profiling has been demonstrated as a challenging option for a comprehensive characterisation of small molecules occurring in plants, since their pattern may reflect the impact of various external factors. In a two-year pilot study, concerned with the classification of organic versus conventional crops, ambient mass spectrometry consisting of a direct analysis in real time (DART) ion source and a time-of-flight mass spectrometer (TOFMS) was employed. This novel methodology was tested on 40 tomato and 24 pepper samples grown under specified conditions. To calculate statistical models, the obtained data (mass spectra) were processed by the principal component analysis (PCA) followed by linear discriminant analysis (LDA). The results from the positive ionisation mode enabled better differentiation between organic and conventional samples than the results from the negative mode. In this case, the recognition ability obtained by LDA was 97.5% for tomato and 100% for pepper samples and the prediction abilities were above 80% for both sample sets. The results suggest that the year of production had stronger influence on the metabolomic fingerprints compared with the type of farming (organic versus conventional). In any case, DART-TOFMS is a promising tool for rapid screening of samples. Establishing comprehensive (multi-sample) long-term databases may further help to improve the quality of statistical classification models.

  1. Double sampling to estimate density and population trends in birds

    USGS Publications Warehouse

    Bart, Jonathan; Earnst, Susan L.

    2002-01-01

    We present a method for estimating density of nesting birds based on double sampling. The approach involves surveying a large sample of plots using a rapid method such as uncorrected point counts, variable circular plot counts, or the recently suggested double-observer method. A subsample of those plots is also surveyed using intensive methods to determine actual density. The ratio of the mean count on those plots (using the rapid method) to the mean actual density (as determined by the intensive searches) is used to adjust results from the rapid method. The approach works well when results from the rapid method are highly correlated with actual density. We illustrate the method with three years of shorebird surveys from the tundra in northern Alaska. In the rapid method, surveyors covered ~10 ha h-1 and surveyed each plot a single time. The intensive surveys involved three thorough searches, required ~3 h ha-1, and took 20% of the study effort. Surveyors using the rapid method detected an average of 79% of birds present. That detection ratio was used to convert the index obtained in the rapid method into an essentially unbiased estimate of density. Trends estimated from several years of data would also be essentially unbiased. Other advantages of double sampling are that (1) the rapid method can be changed as new methods become available, (2) domains can be compared even if detection rates differ, (3) total population size can be estimated, and (4) valuable ancillary information (e.g. nest success) can be obtained on intensive plots with little additional effort. We suggest that double sampling be used to test the assumption that rapid methods, such as variable circular plot and double-observer methods, yield density estimates that are essentially unbiased. The feasibility of implementing double sampling in a range of habitats needs to be evaluated.

  2. Analysis of total oil and fatty acids composition by near infrared reflectance spectroscopy in edible nuts

    NASA Astrophysics Data System (ADS)

    Kandala, Chari V.; Sundaram, Jaya

    2014-10-01

    Near Infrared (NIR) Reflectance spectroscopy has established itself as an important tool in quantifying water and oil present in various food materials. It is rapid and nondestructive, easier to use, and does not require processing the samples with corrosive chemicals that would render them non-edible. Earlier, the samples had to be ground into powder form before making any measurements. With the development of new soft ware packages, NIR techniques could now be used in the analysis of intact grain and nuts. While most of the commercial instruments presently available work well with small grain size materials such as wheat and corn, the method present here is suitable for large kernel size products such as shelled or in-shell peanuts. Absorbance spectra were collected from 400 nm to 2500 nm using a NIR instrument. Average values of total oil contents (TOC) of peanut samples were determined by standard extraction methods, and fatty acids were determined using gas chromatography. Partial least square (PLS) analysis was performed on the calibration set of absorption spectra, and models were developed for prediction of total oil and fatty acids. The best model was selected based on the coefficient of determination (R2), Standard error of prediction (SEP) and residual percent deviation (RPD) values. Peanut samples analyzed showed RPD values greater than 5.0 for both absorbance and reflectance models and thus could be used for quality control and analysis. Ability to rapidly and nondestructively measure the TOC, and analyze the fatty acid composition, will be immensely useful in peanut varietal improvement as well as in the grading process of grain and nuts.

  3. Building a better sticky trap: description of an easy-to-use trap and pole mount for quantifying the abundance of adult aquatic insects

    USGS Publications Warehouse

    Smith, Joshua T.; Kennedy, Theodore A.; Muehlbauer, Jeffrey D.

    2014-01-01

    Insect emergence is a fundamental process in freshwaters. It is a critical life-history stage for aquatic insects and provides an important prey resource for terrestrial and aquatic consumers. Sticky traps are increasingly being used to sample these insects. The most common design consists of an acetate sheet coated with a nondrying adhesive that is attached to a wire frame or cylinder. These traps must be prepared at the deployment site, a process that can be time consuming and difficult given the vagaries of field conditions. Our goals were to develop a sturdy, low-cost sticky trap that could be prepared in advance, rapidly deployed and recovered in the field, and used to estimate the flight direction of insects. We used 150-mm Petri dishes with lids. The dishes can be coated cleanly and consistently with Tangle-Trap® adhesive. Deploying traps is simple and requires only a pole set near the body of water being sampled. Four dishes can be attached to the pole using Velcro and aligned in 4 different directions to enable quantification of insect flight direction. After sampling, Petri dishes can be taped closed, packed in boxes, and stored indefinitely. Petri traps are comparable in price to standard acetate sheet traps at ∼US$0.50/directional deployment, but they require more space for storage than acetate sheet traps. However, a major benefit of Petri traps is that field deployment times are ⅓ those of acetate traps. Our study demonstrated that large Petri dishes are an ideal platform for sampling postemergent adult aquatic insects, particularly when the study design involves estimating flight direction and when rapid deployment and recovery of traps is critical.

  4. Integration of continuous-flow sampling with microchip electrophoresis using poly(dimethylsiloxane)-based valves in a reversibly sealed device.

    PubMed

    Li, Michelle W; Martin, R Scott

    2007-07-01

    Here we describe a reversibly sealed microchip device that incorporates poly(dimethylsiloxane) (PDMS)-based valves for the rapid injection of analytes from a continuously flowing stream into a channel network for analysis with microchip electrophoresis. The microchip was reversibly sealed to a PDMS-coated glass substrate and microbore tubing was used for the introduction of gas and fluids to the microchip device. Two pneumatic valves were incorporated into the design and actuated on the order of hundreds of milliseconds, allowing analyte from a continuously flowing sampling stream to be injected into an electrophoresis separation channel. The device was characterized in terms of the valve actuation time and pushback voltage. It was also found that the addition of sodium dodecyl sulfate (SDS) to the buffer system greatly increased the reproducibility of the injection scheme and enabled the analysis of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide. Results from continuous injections of a 0.39 nL fluorescein plug into the optimized system showed that the injection process was reproducible (RSD of 0.7%, n = 10). Studies also showed that the device was capable of monitoring off-chip changes in concentration with a device lag time of 90 s. Finally, the ability of the device to rapidly monitor on-chip concentration changes was demonstrated by continually sampling from an analyte plug that was derivatized upstream from the electrophoresis/continuous flow interface. A reversibly sealed device of this type will be useful for the continuous monitoring and analysis of processes that occur either off-chip (such as microdialysis sampling) or on-chip from other integrated functions.

  5. A rapid micro quantification method of paracetamol in suppositories using differential scanning calorimetry.

    PubMed

    Noordin, Mohamed I; Chung, L Y

    2004-01-01

    This study adopts Differential Scanning Calorimetry (DSC) to analyze the thermal properties of samples (2.5-4.0 mg) from the tip, middle, and base sections of individual paracetamol suppositories, which were sampled carefully using a stainless steel scalpel. The contents of paracetamol present in the samples obtained from these sections were determined from the enthalpies of fusion of paracetamol and expressed as % w/w paracetamol to allow comparison of the amount of paracetamol found in each section. The tip, middle, and base sections contained 10.1+/-0.2%, 10.1+/-0.2%, and 10.3+/-0.2% w/w paracetamol, and are statistically similar (One-way anova; p>0.05). This indicates that the preparation technique adopted produces high quality suppositories in terms of content uniformity. The contents of paracetamol in the 120-mg paracetamol suppositories determined by DSC and UV spectrophotometry were statistically equivalent (Students's t-test; p>0.05), 120.8+/-2.6 mg and 120.8+/-1.5 mg, respectively, making DSC a clear alternative method for the measurement of content of drug in suppositories. The main advantages of the method are that samples of only 2.5-4.0 mg are required and the procedure does not require an extraction process, which allows for the analysis to be completed rapidly. In addition, it is highly sensitive and reproducible, with the lower detection limit at 4.0% w/w paracetamol, which is about 2.5 times lower than the content of paracetamol (10% w/w) present in our 120-mg paracetamol suppositories and commercial paracetamol suppositories, which contained about 125 mg paracetamol. Therefore, this method is particularly suited for determination of content uniformity in individual suppositories in quality control (QC) and in process quality control (PQC).

  6. Exploring the cause of initially reactive bovine brains on rapid tests for BSE

    PubMed Central

    Dudas, Sandor; James, Jace; Anderson, Renee; Czub, Stefanie

    2015-01-01

    ABSTRACT Bovine spongiform encephalopathy (BSE) is an invariably fatal prion disease of cattle. The identification of the zoonotic potential of BSE prompted safety officials to initiate surveillance testing for this disease. In Canada, BSE surveillance is primarily focused on high risk cattle including animals which are dead, down and unable to rise, diseased or distressed. This targeted surveillance results in the submission of brain samples with a wide range of tissue autolysis and associated contaminants. These contaminants have the potential to interfere with important steps of surveillance tests resulting in initially positive test results requiring additional testing to confirm the disease status of the animal. The current tests used for BSE screening in Canada utilize the relative protease resistance of the prion protein gained when it misfolds from PrPC to PrPSc as part of the disease process. Proteinase K completely digests PrPC in normal brains, but leaves most of the PrPSc in BSE positive brains intact which is detected using anti-prion antibodies. These tests are highly reliable but occasionally give rise to initially reactive/false positive results. Test results for these reactive samples were close to the positive/negative cut-off on a sub set of test platforms. This is in contrast to all of the previous Canadian positive samples whose numeric values on these same test platforms were 10 to 100 fold greater than the test positive/negative cut-off. Here we explore the potential reason why a sample is repeatedly positive on a sub-set of rapid surveillance tests, but negative on other test platforms. In order to better understand and identify what might cause these initial reactions, we have conducted a variety of rapid and confirmatory assays as well as bacterial isolation and identification on BSE positive, negative and initially reactive samples. We observed high levels of viable bacterial contamination in initially reactive samples suggesting that the reactivity may be related to bacterial factors. Several bacteria isolated from the initially reactive samples have characteristics of biofilm forming bacteria and this extracellular matrix might play a role in preventing complete digestion of PrPC in these samples. PMID:26689488

  7. Emerging Microtechnologies and Automated Systems for Rapid Bacterial Identification and Antibiotic Susceptibility Testing

    PubMed Central

    Li, Yiyan; Yang, Xing; Zhao, Weian

    2018-01-01

    Rapid bacterial identification (ID) and antibiotic susceptibility testing (AST) are in great demand due to the rise of drug-resistant bacteria. Conventional culture-based AST methods suffer from a long turnaround time. By necessity, physicians often have to treat patients empirically with antibiotics, which has led to an inappropriate use of antibiotics, an elevated mortality rate and healthcare costs, and antibiotic resistance. Recent advances in miniaturization and automation provide promising solutions for rapid bacterial ID/AST profiling, which will potentially make a significant impact in the clinical management of infectious diseases and antibiotic stewardship in the coming years. In this review, we summarize and analyze representative emerging micro- and nanotechnologies, as well as automated systems for bacterial ID/AST, including both phenotypic (e.g., microfluidic-based bacterial culture, and digital imaging of single cells) and molecular (e.g., multiplex PCR, hybridization probes, nanoparticles, synthetic biology tools, mass spectrometry, and sequencing technologies) methods. We also discuss representative point-of-care (POC) systems that integrate sample processing, fluid handling, and detection for rapid bacterial ID/AST. Finally, we highlight major remaining challenges and discuss potential future endeavors toward improving clinical outcomes with rapid bacterial ID/AST technologies. PMID:28850804

  8. Emerging Microtechnologies and Automated Systems for Rapid Bacterial Identification and Antibiotic Susceptibility Testing.

    PubMed

    Li, Yiyan; Yang, Xing; Zhao, Weian

    2017-12-01

    Rapid bacterial identification (ID) and antibiotic susceptibility testing (AST) are in great demand due to the rise of drug-resistant bacteria. Conventional culture-based AST methods suffer from a long turnaround time. By necessity, physicians often have to treat patients empirically with antibiotics, which has led to an inappropriate use of antibiotics, an elevated mortality rate and healthcare costs, and antibiotic resistance. Recent advances in miniaturization and automation provide promising solutions for rapid bacterial ID/AST profiling, which will potentially make a significant impact in the clinical management of infectious diseases and antibiotic stewardship in the coming years. In this review, we summarize and analyze representative emerging micro- and nanotechnologies, as well as automated systems for bacterial ID/AST, including both phenotypic (e.g., microfluidic-based bacterial culture, and digital imaging of single cells) and molecular (e.g., multiplex PCR, hybridization probes, nanoparticles, synthetic biology tools, mass spectrometry, and sequencing technologies) methods. We also discuss representative point-of-care (POC) systems that integrate sample processing, fluid handling, and detection for rapid bacterial ID/AST. Finally, we highlight major remaining challenges and discuss potential future endeavors toward improving clinical outcomes with rapid bacterial ID/AST technologies.

  9. Space Weathering Rates in Lunar and Itokawa Samples

    NASA Technical Reports Server (NTRS)

    Keller, L. P.; Berger, E. L.

    2017-01-01

    Space weathering alters the chemistry, microstructure, and spectral proper-ties of grains on the surfaces of airless bodies by two major processes: micrometeorite impacts and solar wind interactions. Investigating the nature of space weathering processes both in returned samples and in remote sensing observations provides information fundamental to understanding the evolution of airless body regoliths, improving our ability to determine the surface composition of asteroids, and linking meteorites to specific asteroidal parent bodies. Despite decades of research into space weathering processes and their effects, we still know very little about weathering rates. For example, what is the timescale to alter the reflectance spectrum of an ordinary chondrite meteorite to resemble the overall spectral shape and slope from an S-type asteroid? One approach to answering this question has been to determine ages of asteroid families by dynamical modeling and determine the spectral proper-ties of the daughter fragments. However, large differences exist between inferred space weathering rates and timescales derived from laboratory experiments, analysis of asteroid family spectra and the space weathering styles; estimated timescales range from 5000 years up to 108 years. Vernazza et al. concluded that solar wind interactions dominate asteroid space weathering on rapid timescales of 10(exp 4)-10(exp 6) years. Shestopalov et al. suggested that impact-gardening of regolith particles and asteroid resurfacing counteract the rapid progress of solar wind optical maturation of asteroid surfaces and proposed a space weathering timescale of 10(exp 5)-10(exp 6) years.

  10. Rapid determination of actinides in asphalt samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2014-01-12

    A new rapid method for the determination of actinides in asphalt samples has been developed that can be used in emergency response situations or for routine analysis If a radiological dispersive device (RDD), Improvised Nuclear Device (IND) or a nuclear accident such as the accident at the Fukushima Nuclear Power Plant in March, 2011 occurs, there will be an urgent need for rapid analyses of many different environmental matrices, including asphalt materials, to support dose mitigation and environmental clean up. The new method for the determination of actinides in asphalt utilizes a rapid furnace step to destroy bitumen and organicsmore » present in the asphalt and sodium hydroxide fusion to digest the remaining sample. Sample preconcentration steps are used to collect the actinides and a new stacked TRU Resin + DGA Resin column method is employed to separate the actinide isotopes in the asphalt samples. The TRU Resin plus DGA Resin separation approach, which allows sequential separation of plutonium, uranium, americium and curium isotopes in asphalt samples, can be applied to soil samples as well.« less

  11. Simultaneous quantification of amoxicillin and potassium clavulanate in different commercial drugs using PIXE technique

    NASA Astrophysics Data System (ADS)

    Bejjani, A.; Roumié, M.; Akkad, S.; El-Yazbi, F.; Nsouli, B.

    2016-03-01

    We have demonstrated, in previous studies that Particle Induced X-ray Emission (PIXE) is one of the most rapid and accurate choices for quantification of an active ingredient, in a solid drug, from the reactions induced on its specific heteroatom using pellets made from original tablets. In this work, PIXE is used, for the first time, for simultaneous quantification of two active ingredients, amoxicillin trihydrate and potassium clavulanate, in six different commercial antibiotic type of drugs. Since the quality control process of a drug covers a large number of samples, the scope of this study was also to found the most rapid and low cost sample preparation needed to analyze these drugs with a good precision. The chosen drugs were analyzed in their tablets' "as received" form, in pellets made from the powder of the tablets and also in pellets made from the powder of the tablets after being heated up to 70 °C to avoid any molecular destruction until constant weight and removal of humidity. The quantification validity related to the aspects of each sample preparation (homogeneity of the drug components and humidity) are presented and discussed.

  12. Rapid and Sensitive Detection of sFAT-1 Transgenic Pigs by Visual Loop-Mediated Isothermal Amplification.

    PubMed

    Tao, Chenyu; Yang, Yalan; Li, Xunbi; Zheng, Xinmin; Ren, Hongyan; Li, Kui; Zhou, Rong

    2016-07-01

    Genetically modified (GM) livestock have the potential to contribute to improving the environment and human health, with consumption of fewer resources and reduced waste production. However, the transgene process also poses risks. The safety assessment and control of transgenic animal products have drawn wide attention, and the relevant regulations and technology are being developed. Quick testing technology plays a significant role in on-site and customs sampling. Nowadays, loop-mediated isothermal amplification (LAMP) was widely applied in nucleic acid analysis because of its simplicity, rapidity, high efficiency and specificity. In this study, a specific, sensitive detection system for detecting sFAT-1 transgenic pigs was designed. A set of six primers including two loop primers was designed for the target sequence. The DNA samples were amplified in less than 1 h at the optimized temperature and detecting by both Nephelometer LA-320c and unaided eyes directly adding calcein. The detection limit of sFAT-1 LAMP was as low as 1.26 ng/μL. Furthermore, blind tests of transgenic and non-transgenic DNA samples were all correctly detected. Hence, the results in this study demonstrated that LAMP is a very useful tool for transgenic detection.

  13. Identification of irradiated refrigerated pork with the DNA comet assay

    NASA Astrophysics Data System (ADS)

    Araújo, M. M.; Marin-Huachaca, N. S.; Mancini-Filho, J.; Delincée, H.; Villavicencio, A. L. C. H.

    2004-09-01

    Food irradiation can contribute to a safer and more plentiful food supply by inactivating pathogens, eradicating pests and by extending shelf-life. Particularly in the case of pork meat, this process could be a useful way to inactivate harmful parasites such as Trichinella and Taenia solium. Ionizing radiation causes damage to the DNA of the cells (e.g. strand breaks), which can be used to detect irradiated food. Microelectrophoresis of single cells (``Comet Assay'') is a simple and rapid test for DNA damage and can be used over a wide dose range and for a variety of products. Refrigerated pork meat was irradiated with a 60Co source, Gammacell 220 (A.E.C.L.) installed in IPEN (Sa~o Paulo, Brazil). The doses given were 0, 1.5, 3.0 and 4.5kGy for refrigerated samples. Immediately after irradiation the samples were returned to the refrigerator (6°C). Samples were kept in the refrigerator after irradiation. Pork meat was analyzed 1, 8 and 10 days after irradiation using the DNA ``Comet Assay''. This method showed to be an inexpensive and rapid technique for qualitative detection of irradiation treatment.

  14. Rapid Polyol-Assisted Microwave Synthesis of Nanocrystalline LiFePO4/C Cathode for Lithium-Ion Batteries.

    PubMed

    Paul, Baboo Joseph; Gim, Jihyeon; Baek, Sora; Kang, Jungwon; Song, Jinju; Kim, Sungjin; Kim, Jaekook

    2015-08-01

    Nanocrystalline LiFePO4/C has been synthesized under a very short period of time (90 sec) using a polyol-assisted microwave heating synthesis technique. The X-ray diffraction (XRD) data indicates that the rapidly synthesized materials correspond to phase pure olivine. Post-annealing of the as-prepared sample at 600 °C in argon atmosphere yields highly crystalline LiFePO4/C. The morphology of the samples studied using scanning electron microscopy (SEM) reveals the presence of secondary particles formed from aggregation of primary particles in the range of 30-50 nm. Transmission electron microscopy (TEM) images reveal a thin carbon layer coating on the surface of the primary particle. The charge/discharge studies indicate that the as-prepared and annealed LiFePO4/C samples delivered initial discharge capacities of 126 and 160 mA h g-1, respectively, with good capacity retentions at 0.05 mA cm-2 current densities. The post-annealing process indeed improves the crystallinity of the LiFePO4 nanocrystals, which enhances the electrode performance of LiFePO4/C.

  15. Monitoring sea lamprey pheromones and their degradation using rapid stream-side extraction coupled with UPLC-MS/MS

    USGS Publications Warehouse

    Wang, Huiyong; Johnson, Nicholas; Bernardy, Jeffrey; Hubert, Terry; Li, Weiming

    2013-01-01

    Pheromones guide adult sea lamprey (Petromyzon marinus) to suitable spawning streams and mates, and therefore, when quantified, can be used to assess population size and guide management. Here, we present an efficient sample preparation method where 100 mL of river water was spiked with deuterated pheromone as an internal standard and underwent rapid field-based SPE and elution in the field. The combination of field extraction with laboratory UPLC-MS/MS reduced the sample consumption from 1 to 0.1 L, decreased the sample process time from more than 1 h to 10 min, and increased the precision and accuracy. The sensitivity was improved more than one order of magnitude compared with the previous method. The influences of experimental conditions were assessed to optimize the separation and peak shapes. The analytical method has been validated by studies of stability, selectivity, precision, and linearity and by the determination of the limits of detection and quantification. The method was used to quantify pheromone concentration from five streams tributary to Lake Ontario and to estimate that the environmental half-life of 3kPZS is about 26 h.

  16. Rapid Sample Processing for Detection of Food-Borne Pathogens via Cross-Flow Microfiltration

    PubMed Central

    Li, Xuan; Ximenes, Eduardo; Amalaradjou, Mary Anne Roshni; Vibbert, Hunter B.; Foster, Kirk; Jones, Jim; Liu, Xingya; Bhunia, Arun K.

    2013-01-01

    This paper reports an approach to enable rapid concentration and recovery of bacterial cells from aqueous chicken homogenates as a preanalytical step of detection. This approach includes biochemical pretreatment and prefiltration of food samples and development of an automated cell concentration instrument based on cross-flow microfiltration. A polysulfone hollow-fiber membrane module having a nominal pore size of 0.2 μm constitutes the core of the cell concentration instrument. The aqueous chicken homogenate samples were circulated within the cross-flow system achieving 500- to 1,000-fold concentration of inoculated Salmonella enterica serovar Enteritidis and naturally occurring microbiota with 70% recovery of viable cells as determined by plate counting and quantitative PCR (qPCR) within 35 to 45 min. These steps enabled 10 CFU/ml microorganisms in chicken homogenates or 102 CFU/g chicken to be quantified. Cleaning and sterilizing the instrument and membrane module by stepwise hydraulic and chemical cleaning (sodium hydroxide and ethanol) enabled reuse of the membrane 15 times before replacement. This approach begins to address the critical need for the food industry for detecting food pathogens within 6 h or less. PMID:24014538

  17. Study of protein folding under native conditions by rapidly switching the hydrostatic pressure inside an NMR sample cell

    PubMed Central

    Charlier, Cyril; Alderson, T. Reid; Courtney, Joseph M.; Ying, Jinfa; Anfinrud, Philip

    2018-01-01

    In general, small proteins rapidly fold on the timescale of milliseconds or less. For proteins with a substantial volume difference between the folded and unfolded states, their thermodynamic equilibrium can be altered by varying the hydrostatic pressure. Using a pressure-sensitized mutant of ubiquitin, we demonstrate that rapidly switching the pressure within an NMR sample cell enables study of the unfolded protein under native conditions and, vice versa, study of the native protein under denaturing conditions. This approach makes it possible to record 2D and 3D NMR spectra of the unfolded protein at atmospheric pressure, providing residue-specific information on the folding process. 15N and 13C chemical shifts measured immediately after dropping the pressure from 2.5 kbar (favoring unfolding) to 1 bar (native) are close to the random-coil chemical shifts observed for a large, disordered peptide fragment of the protein. However, 15N relaxation data show evidence for rapid exchange, on a ∼100-μs timescale, between the unfolded state and unstable, structured states that can be considered as failed folding events. The NMR data also provide direct evidence for parallel folding pathways, with approximately one-half of the protein molecules efficiently folding through an on-pathway kinetic intermediate, whereas the other half fold in a single step. At protein concentrations above ∼300 μM, oligomeric off-pathway intermediates compete with folding of the native state. PMID:29666248

  18. A simple and rapid technique for the authentication of the ginseng cultivar, Yunpoong, using an SNP marker in a large sample of ginseng leaves.

    PubMed

    Sun, Hua; Wang, Hong-Tao; Kwon, Woo-Saeng; Kim, Yeon-Ju; In, Jun-Gyo; Yang, Deok-Chun

    2011-11-01

    Yunpoong is an important Korean ginseng (Panax ginseng C. A. Meyer) cultivar, but no molecular marker has been available to identify Yunpoong from other cultivars. In this study, we developed a single nucleotide polymorphism (SNP) marker for Yunpoong based on analysis of expressed sequence tags (ESTs) in an exon region of the glyceraldehyde 3-phosphate dehydrogenase (GAPDH) gene. This SNP marker had high specificity to authenticate Yunpoong in twelve different main ginseng cultivars. For application of the molecular marker, a rapid identification method was established based on the NaOH-Tris method and real-time polymerase chain reaction (PCR) in order to ensure more efficiency in the cultivar selection. The biggest feature of the NaOH-Tris method was that it made the extraction of DNA very simple and rapid in young leaf tissues. We only spent 1 min to extract DNA and directly used it to do PCR. In this report, the conventional DNA extraction method was used to develop molecular marker process, and the NaOH-Tris method was applied in screening large numbers of cultivars. Moreover, the greatest advantage of the real-time PCR compared with traditional PCR, is time saving and high efficiency. Thus, this strategy provides a rapid and reliable method for the specific identification of Yunpoong in a large number of samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Quantitative, multiplexed workflow for deep analysis of human blood plasma and biomarker discovery by mass spectrometry.

    PubMed

    Keshishian, Hasmik; Burgess, Michael W; Specht, Harrison; Wallace, Luke; Clauser, Karl R; Gillette, Michael A; Carr, Steven A

    2017-08-01

    Proteomic characterization of blood plasma is of central importance to clinical proteomics and particularly to biomarker discovery studies. The vast dynamic range and high complexity of the plasma proteome have, however, proven to be serious challenges and have often led to unacceptable tradeoffs between depth of coverage and sample throughput. We present an optimized sample-processing pipeline for analysis of the human plasma proteome that provides greatly increased depth of detection, improved quantitative precision and much higher sample analysis throughput as compared with prior methods. The process includes abundant protein depletion, isobaric labeling at the peptide level for multiplexed relative quantification and ultra-high-performance liquid chromatography coupled to accurate-mass, high-resolution tandem mass spectrometry analysis of peptides fractionated off-line by basic pH reversed-phase (bRP) chromatography. The overall reproducibility of the process, including immunoaffinity depletion, is high, with a process replicate coefficient of variation (CV) of <12%. Using isobaric tags for relative and absolute quantitation (iTRAQ) 4-plex, >4,500 proteins are detected and quantified per patient sample on average, with two or more peptides per protein and starting from as little as 200 μl of plasma. The approach can be multiplexed up to 10-plex using tandem mass tags (TMT) reagents, further increasing throughput, albeit with some decrease in the number of proteins quantified. In addition, we provide a rapid protocol for analysis of nonfractionated depleted plasma samples analyzed in 10-plex. This provides ∼600 quantified proteins for each of the ten samples in ∼5 h of instrument time.

  20. Novel Polymerase Spiral Reaction (PSR) for rapid visual detection of Bovine Herpesvirus 1 genomic DNA from aborted bovine fetus and semen.

    PubMed

    Malla, Javed Ahmed; Chakravarti, Soumendu; Gupta, Vikas; Chander, Vishal; Sharma, Gaurav Kumar; Qureshi, Salauddin; Mishra, Adhiraj; Gupta, Vivek Kumar; Nandi, Sukdeb

    2018-02-20

    Bovine herpesvirus-1 (BHV-1) is a major viral pathogen affecting bovines leading to various clinical manifestations and causes significant economic impediment in modern livestock production system. Rapid, accurate and sensitive detection of BHV-1 infection at frozen semen stations or at dairy herds remains a priority for control of BHV-1 spread to susceptible population. Polymerase Spiral Reaction (PSR), a novel addition in the gamut of isothermal techniques, has been successfully implemented in initial optimization for detection of BHV-1 genomic DNA and further validated in clinical samples. The developed PSR assay has been validated for detection of BHV-1 from bovine semen (n=99), a major source of transmission of BHV-1 from breeding bulls to susceptible dams in artificial insemination programs. The technique has also been used for screening of BHV-1 DNA from suspected aborted fetal tissues (n=25). The developed PSR technique is 100 fold more sensitive than conventional PCR and comparable to real-time PCR. The PSR technique has been successful in detecting 13 samples positive for BHV-1 DNA in bovine semen, 4 samples more than conventional PCR. The aborted fetal tissues were negative for presence of BHV-1 DNA. The presence of BHV-1 in bovine semen samples raises a pertinent concern for extensively screening of semen from breeding bulls before been used for artificial insemination process. PSR has all the attributes for becoming a method of choice for rapid, accurate and sensitive detection of BHV-1 DNA at frozen semen stations or at dairy herds in resource constrained settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. An improved, rapid competitive ELISA using a novel conserved 3B epitope for the detection of serum antibodies to foot-and-mouth disease virus.

    PubMed

    Chung, Chungwon J; Clavijo, Alfonso; Bounpheng, Mangkey A; Uddowla, Sabena; Sayed, Abu; Dancho, Brooke; Olesen, Ian C; Pacheco, Juan; Kamicker, Barbara J; Brake, David A; Bandaranayaka-Mudiyanselage, Carey L; Lee, Stephen S; Rai, Devendra K; Rieder, Elizabeth

    2018-06-01

    The highly contagious foot-and-mouth disease virus (FMDV) afflicts cloven-hoofed animals, resulting in significant costs because of loss of trade and recovery from disease. We developed a sensitive, specific, and rapid competitive ELISA (cELISA) to detect serum antibodies to FMDV. The cELISA utilized a monoclonal blocking antibody specific for a highly conserved FMDV nonstructural 3B epitope, a recombinant mutant FMDV 3ABC coating protein, and optimized format variables including serum incubation for 90 min at 20-25°C. Samples from 16 animals experimentally infected with one FMDV serotype (A, O, Asia, or SAT-1) demonstrated early detection capacity beginning 7 d post-inoculation. All samples from 55 vesicular stomatitis virus antibody-positive cattle and 44 samples from cloven-hoofed animals affected by non-FMD vesicular diseases were negative in the cELISA, demonstrating 100% analytical specificity. The diagnostic sensitivity was 100% against sera from 128 cattle infected with isolates of all FMDV serotypes, emphasizing serotype-agnostic results. Diagnostic specificities of U.S. cattle ( n = 1135) and swine ( n = 207) sera were 99.4% and 100%, respectively. High repeatability and reproducibility were demonstrated with 3.1% coefficient of variation in percent inhibition data and 100% agreement using 2 kit lots and 400 negative control serum samples, with no difference between bench and biosafety cabinet operation. Negative results from vaccinated, uninfected cattle, pig, and sheep sera confirmed the DIVA (differentiate infected from vaccinated animals) capability. This rapid (<3 h), select agent-free assay with high sensitivity and specificity, DIVA capability, and room temperature processing capability will serve as a useful tool in FMDV surveillance, emergency preparedness, response, and outbreak recovery programs.

  2. Adventures in Modern Time Series Analysis: From the Sun to the Crab Nebula and Beyond

    NASA Technical Reports Server (NTRS)

    Scargle, Jeffrey

    2014-01-01

    With the generation of long, precise, and finely sampled time series the Age of Digital Astronomy is uncovering and elucidating energetic dynamical processes throughout the Universe. Fulfilling these opportunities requires data effective analysis techniques rapidly and automatically implementing advanced concepts. The Time Series Explorer, under development in collaboration with Tom Loredo, provides tools ranging from simple but optimal histograms to time and frequency domain analysis for arbitrary data modes with any time sampling. Much of this development owes its existence to Joe Bredekamp and the encouragement he provided over several decades. Sample results for solar chromospheric activity, gamma-ray activity in the Crab Nebula, active galactic nuclei and gamma-ray bursts will be displayed.

  3. [Development of sample pretreatment techniques-rapid detection coupling methods for food security analysis].

    PubMed

    Huang, Yichun; Ding, Weiwei; Zhang, Zhuomin; Li, Gongke

    2013-07-01

    This paper summarizes the recent developments of the rapid detection methods for food security, such as sensors, optical techniques, portable spectral analysis, enzyme-linked immunosorbent assay, portable gas chromatograph, etc. Additionally, the applications of these rapid detection methods coupled with sample pretreatment techniques in real food security analysis are reviewed. The coupling technique has the potential to provide references to establish the selective, precise and quantitative rapid detection methods in food security analysis.

  4. Quantitative assessment of anthrax vaccine immunogenicity using the dried blood spot matrix.

    PubMed

    Schiffer, Jarad M; Maniatis, Panagiotis; Garza, Ilana; Steward-Clark, Evelene; Korman, Lawrence T; Pittman, Phillip R; Mei, Joanne V; Quinn, Conrad P

    2013-03-01

    The collection, processing and transportation to a testing laboratory of large numbers of clinical samples during an emergency response situation present significant cost and logistical issues. Blood and serum are common clinical samples for diagnosis of disease. Serum preparation requires significant on-site equipment and facilities for immediate processing and cold storage, and significant costs for cold-chain transport to testing facilities. The dried blood spot (DBS) matrix offers an alternative to serum for rapid and efficient sample collection with fewer on-site equipment requirements and considerably lower storage and transport costs. We have developed and validated assay methods for using DBS in the quantitative anti-protective antigen IgG enzyme-linked immunosorbent assay (ELISA), one of the primary assays for assessing immunogenicity of anthrax vaccine and for confirmatory diagnosis of Bacillus anthracis infection in humans. We have also developed and validated high-throughput data analysis software to facilitate data handling for large clinical trials and emergency response. Published by Elsevier Ltd.

  5. Influence of alumina on mineralogy and environmental properties of zinc-copper smelting slags

    NASA Astrophysics Data System (ADS)

    Mostaghel, Sina; Samuelsson, Caisa; Björkman, Bo

    2013-03-01

    An iron-silicate slag, from a zinc-copper smelting process, and mixtures of this slag with 5wt%, 10wt%, and 15wt% alumina addition were re-melted, semi-rapidly solidified, and characterized using scanning electron microscopy equipped with energy dispersive spectroscopy, and X-ray diffraction. The FactSage™6.2 thermodynamic package was applied to compare the stable phases at equilibrium conditions with experimental characterization. A standard European leaching test was also carried out for all samples to investigate the changes in leaching behaviour because of the addition of alumina. Results show that the commonly reported phases for slags from copper and zinc production processes (olivine, pyroxene, and spinel) are the major constituents of the current samples. A correlation can be seen between mineralogical characteristics and leaching behaviours. The sample with 10wt% alumina addition, which contains high amounts of spinels and lower amounts of the other soluble phases, shows the lowest leachabilities for most of the elements.

  6. Monitoring of beer fermentation based on hybrid electronic tongue.

    PubMed

    Kutyła-Olesiuk, Anna; Zaborowski, Michał; Prokaryn, Piotr; Ciosek, Patrycja

    2012-10-01

    Monitoring of biotechnological processes, including fermentation is extremely important because of the rapidly occurring changes in the composition of the samples during the production. In the case of beer, the analysis of physicochemical parameters allows for the determination of the stage of fermentation process and the control of its possible perturbations. As a tool to control the beer production process a sensor array can be used, composed of potentiometric and voltammetric sensors (so-called hybrid Electronic Tongue, h-ET). The aim of this study is to apply electronic tongue system to distinguish samples obtained during alcoholic fermentation. The samples originate from batch of homemade beer fermentation and from two stages of the process: fermentation reaction and maturation of beer. The applied sensor array consists of 10 miniaturized ion-selective electrodes (potentiometric ET) and silicon based 3-electrode voltammetric transducers (voltammetric ET). The obtained results were processed using Partial Least Squares (PLS) and Partial Least Squares-Discriminant Analysis (PLS-DA). For potentiometric data, voltammetric data, and combined potentiometric and voltammetric data, comparison of the classification ability was conducted based on Root Mean Squared Error (RMSE), sensitivity, specificity, and coefficient F calculation. It is shown, that in the contrast to the separately used techniques, the developed hybrid system allowed for a better characterization of the beer samples. Data fusion in hybrid ET enables to obtain better results both in qualitative analysis (RMSE, specificity, sensitivity) and in quantitative analysis (RMSE, R(2), a, b). Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Rapid authentication of edible bird's nest by FTIR spectroscopy combined with chemometrics.

    PubMed

    Guo, Lili; Wu, Yajun; Liu, Mingchang; Ge, Yiqiang; Chen, Ying

    2018-06-01

    Edible bird's nests (EBNs) have been traditionally regarded as a kind of medicinal and healthy food in China. For economic reasons, they are frequently subjected to adulteration with some cheaper substitutes, such as Tremella fungus, agar, fried pigskin, and egg white. As a kind of precious and functional product, it is necessary to establish a robust method for the rapid authentication of EBNs with small amounts of samples by simple processes. In this study, the Fourier transform infrared spectroscopy (FTIR) system was utilized and its feasibility for identification of EBNs was verified. FTIR spectra data of authentic and adulterated EBNs were analyzed by chemometrics analyses including principal component analysis, linear discriminant analysis (LDA), support vector machine (SVM) and one-class partial least squares (OCPLS). The results showed that the established LDA and SVM models performed well and had satisfactory classification ability, with the former 94.12% and the latter 100%. The OCPLS model was developed with prediction sensitivity of 0.937 and specificity of 0.886. Further detection of commercial EBN samples confirmed these results. FTIR is applicable in the scene of rapid authentication of EBNs, especially for quality supervision departments, entry-exit inspection and quarantine, and customs administration. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  8. Rapid motion compensation for prostate biopsy using GPU.

    PubMed

    Shen, Feimo; Narayanan, Ramkrishnan; Suri, Jasjit S

    2008-01-01

    Image-guided procedures have become routine in medicine. Due to the nature of three-dimensional (3-D) structure of the target organs, two-dimensional (2-D) image acquisition is gradually being replaced by 3-D imaging. Specifically in the diagnosis of prostate cancer, biopsy can be performed using 3-D transrectal ultrasound (TRUS) image guidance. Because prostatic cancers are multifocal, it is crucial to accurately guide biopsy needles towards planned targets. Further the gland tends to move due to external physical disturbances, discomfort introduced by the procedure or intrinsic peristalsis. As a result the exact position of the gland must be rapidly updated so as to correspond with the originally acquired 3-D TRUS volume prior to biopsy planning. A graphics processing unit (GPU) is used in this study to compute rapid updates performing 3-D motion compensation via registration of the live 2-D image and the acquired 3-D TRUS volume. The parallel computational framework on the GPU is exploited resulting in mean compute times of 0.46 seconds for updating the position of a live 2-D buffer image containing 91,000 pixels. A 2x sub-sampling resulted in a further improvement to 0.19 seconds. With the increase in GPU multiprocessors and sub-sampling, we observe that real time motion compensation can be achieved.

  9. Soil microbial succession along a chronosequence on a High Arctic glacier foreland, Ny-Ålesund, Svalbard: 10 years' change

    NASA Astrophysics Data System (ADS)

    Yoshitake, Shinpei; Uchida, Masaki; Iimura, Yasuo; Ohtsuka, Toshiyuki; Nakatsubo, Takayuki

    2018-06-01

    Rapid glacial retreat in the High Arctic causes the expansion of new habitats, but the successional trajectories of soil microbial communities are not fully understood. We examined microbial succession along a chronosequence twice with a 10-year interval in a High Arctic glacier foreland. Soil samples were collected from five study sites with different ages and phospholipid fatty acids analysis was conducted to investigate the microbial biomass and community structure. Microbial biomass did not differ significantly between the two sampling times but tended to increase with the chronosequence and showed a significant correlation with soil carbon (C) and nitrogen (N) content. Microbial community structure clearly differed along the chronosequence and was correlated with C and N content. The largest shift in community structure over 10 years was observed in the newly exposed sites after deglaciation. The accumulation of soil organic matter was regarded as an important determinant both of microbial biomass and community structure over the successional period. In contrast, the initial microbial community on the newly exposed soil changed rapidly even in the High Arctic, suggesting that some key soil processes such as C and N cycling can also shift within the relatively short period after rapid glacial retreat.

  10. Flexible thermoset towpregs by electrostatic powder fusion coating

    NASA Technical Reports Server (NTRS)

    Yang, Pei-Hua; Varughese, Babu; Muzzy, John D.

    1991-01-01

    Thermoset prepregs of expoxy and polyimide have been produced by electrostatic deposition of charged fluidized polymer powders on spread continuous fiber tows. The powders are melted onto the fibers by radiant heating to adhere the polymer to the fiber. This process produces towpreg uniformly and rapidly without imposing severe stresses on the fibers. The towpregs produced by this novel process were consolidated to make unidirectional laminates for mechanical testing. Low void content samples have been made and demonstrated by C-scan and scanning electron microscopy. The mechanical properties of unidirectional laminates are equivalent to composites fabricated by conventional techniques.

  11. Alterations in rotation thromboelastometry (ROTEM®) parameters: point-of-care testing vs analysis after pneumatic tube system transport.

    PubMed

    Martin, J; Schuster, T; Moessmer, G; Kochs, E F; Wagner, K J

    2012-10-01

    Thromboelastometry as point-of-care (POC) testing enables the analysis of the clotting process at the bedside, providing rapid results to guide haemostatic therapy. However, POC testing utilizes medical staff who are managing critically ill patients, as non-laboratory personnel may not be sufficiently trained to run the devices. To resolve these problems, thromboelastometry can be performed in the central laboratory and rapid transport of samples can be accomplished via a pneumatic tube system (PTS). This study compares thromboelastometry parameters of blood samples analysed immediately with those analysed after PTS transport. In patients with normal haemostasis, two arterial blood samples were collected from each patient (n=92) in citrated plastic tubes to investigate the assays INTEM (n=35), EXTEM (n=27), and FIBTEM (n=30). One blood sample was analysed immediately, the other sample after PTS transport. Thromboelastometry was performed using a single ROTEM(®) device. The mean clot firmness values were significantly lower for PTS samples in both the INTEM (-0.7 mm cf. -1.1 mm) and EXTEM (-1.4 cf. -1.7 mm) assays. INTEM coagulation time (CT) was significantly lower in PTS samples with a mean difference of -13 s. EXTEM CT was significantly higher in PTS samples with a mean difference of +3.9 s. Thromboelastometry parameters of blood samples analysed after PTS transport are significantly altered compared with those analysed immediately. However, in patients with normal haemostasis, the alterations were small and without clinical consequence, implying that analysis after PTS transport is an acceptable alternative to prompt analysis at the bedside. Further studies should focus on patients with impaired haemostasis.

  12. Reasoning on the Autism Spectrum: A Dual Process Theory Account.

    PubMed

    Brosnan, Mark; Lewton, Marcus; Ashwin, Chris

    2016-06-01

    Dual process theory proposes two distinct reasoning processes in humans, an intuitive style that is rapid and automatic and a deliberative style that is more effortful. However, no study to date has specifically examined these reasoning styles in relation to the autism spectrum. The present studies investigated deliberative and intuitive reasoning profiles in: (1) a non-clinical sample from the general population with varying degrees of autism traits (n = 95), and (2) males diagnosed with ASD (n = 17) versus comparisons (n = 18). Taken together, the results suggest reasoning on the autism spectrum is compatible with the processes proposed by Dual Process Theory and that higher autism traits and ASD are characterised by a consistent bias towards deliberative reasoning (and potentially away from intuition).

  13. Advances in optical information processing IV; Proceedings of the Meeting, Orlando, FL, Apr. 18-20, 1990

    NASA Astrophysics Data System (ADS)

    Pape, Dennis R.

    1990-09-01

    The present conference discusses topics in optical image processing, optical signal processing, acoustooptic spectrum analyzer systems and components, and optical computing. Attention is given to tradeoffs in nonlinearly recorded matched filters, miniature spatial light modulators, detection and classification using higher-order statistics of optical matched filters, rapid traversal of an image data base using binary synthetic discriminant filters, wideband signal processing for emitter location, an acoustooptic processor for autonomous SAR guidance, and sampling of Fresnel transforms. Also discussed are an acoustooptic RF signal-acquisition system, scanning acoustooptic spectrum analyzers, the effects of aberrations on acoustooptic systems, fast optical digital arithmetic processors, information utilization in analog and digital processing, optical processors for smart structures, and a self-organizing neural network for unsupervised learning.

  14. Development of a perfusion reversed-phase high performance liquid chromatography method for the characterisation of maize products using multivariate analysis.

    PubMed

    Rodriguez-Nogales, J M; Garcia, M C; Marina, M L

    2006-02-03

    A perfusion reversed-phase high performance liquid chromatography (RP-HPLC) method has been designed to allow rapid (3.4 min) separations of maize proteins with high resolution. Several factors, such as extraction conditions, temperature, detection wavelength and type and concentration of ion-pairing agent were optimised. A fine optimisation of the gradient elution was also performed by applying experimental design. Commercial maize products for human consumption (flours, precocked flours, fried snacks and extruded snacks) were characterised for the first time by perfusion RP-HPLC and their chromatographic profiles allowed a differentiation among products relating the different technological process used for their preparation. Furthermore, applying discriminant analysis makes it possible to group the samples according with the technological process suffered by maize products, obtaining a good prediction in 92% of the samples.

  15. Micro-balance sensor integrated with atomic layer deposition chamber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinson, Alex B. F.; Libera, Joseph A.; Elam, Jeffrey W.

    The invention is directed to QCM measurements in monitoring ALD processes. Previously, significant barriers remain in the ALD processes and accurate execution. To turn this exclusively dedicated in situ technique into a routine characterization method, an integral QCM fixture was developed. This new design is easily implemented on a variety of ALD tools, allows rapid sample exchange, prevents backside deposition, and minimizes both the footprint and flow disturbance. Unlike previous QCM designs, the fast thermal equilibration enables tasks such as temperature-dependent studies and ex situ sample exchange, further highlighting the feasibility of this QCM design for day-to-day use. Finally, themore » in situ mapping of thin film growth rates across the ALD reactor was demonstrated in a popular commercial tool operating in both continuous and quasi-static ALD modes.« less

  16. A non-viscous-featured fractograph in metallic glasses

    NASA Astrophysics Data System (ADS)

    Yang, G. N.; Shao, Y.; Yao, K. F.

    2016-02-01

    A fractograph of non-viscous feature but pure shear-offsets was found in three-point bending samples of a ductile Pd-Cu-Si metallic glass. A sustainable shear band multiplication with large plasticity during notch propagation was observed. Such non-viscous-featured fractograph was formed by a crack propagation manner of continual multiple shear bands formation in front of the crack-tip, instead of the conventional rapid fracture along shear bands. With a 2D model of crack propagation by multiple shear bands, we showed that such fracture process was achieved by a faster stress relaxation than shear-softening effect in the sample. This study confirmed that the viscous fracture along shear bands could be not a necessary process in ductile metallic glasses fracture, and could provide new ways to understand the plasticity in the shear-softened metallic glasses.

  17. THE COMPREHENSION OF RAPID SPEECH BY THE BLIND, PART III.

    ERIC Educational Resources Information Center

    FOULKE, EMERSON

    A REVIEW OF THE RESEARCH ON THE COMPREHENSION OF RAPID SPEECH BY THE BLIND IDENTIFIES FIVE METHODS OF SPEECH COMPRESSION--SPEECH CHANGING, ELECTROMECHANICAL SAMPLING, COMPUTER SAMPLING, SPEECH SYNTHESIS, AND FREQUENCY DIVIDING WITH THE HARMONIC COMPRESSOR. THE SPEECH CHANGING AND ELECTROMECHANICAL SAMPLING METHODS AND THE NECESSARY APPARATUS HAVE…

  18. A false sense of security? Can tiered approach be trusted to accurately classify immunogenicity samples?

    PubMed

    Jaki, Thomas; Allacher, Peter; Horling, Frank

    2016-09-05

    Detecting and characterizing of anti-drug antibodies (ADA) against a protein therapeutic are crucially important to monitor the unwanted immune response. Usually a multi-tiered approach that initially rapidly screens for positive samples that are subsequently confirmed in a separate assay is employed for testing of patient samples for ADA activity. In this manuscript we evaluate the ability of different methods used to classify subject with screening and competition based confirmatory assays. We find that for the overall performance of the multi-stage process the method used for confirmation is most important where a t-test is best when differences are moderate to large. Moreover we find that, when differences between positive and negative samples are not sufficiently large, using a competition based confirmation step does yield poor classification of positive samples. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. [Techniques for rapid production of monoclonal antibodies for use with antibody technology].

    PubMed

    Kamada, Haruhiko

    2012-01-01

    A monoclonal antibody (Mab), due to its specific binding ability to a target protein, can potentially be one of the most useful tools for the functional analysis of proteins in recent proteomics-based research. However, the production of Mab is a very time-consuming and laborious process (i.e., preparation of recombinant antigens, immunization of animals, preparation of hybridomas), making it the rate-limiting step in using Mabs in high-throughput proteomics research, which heavily relies on comprehensive and rapid methods. Therefore, there is a great demand for new methods to efficiently generate Mabs against a group of proteins identified by proteome analysis. Here, we describe a useful method called "Antibody proteomic technique" for the rapid generations of Mabs to pharmaceutical target, which were identified by proteomic analyses of disease samples (ex. tumor tissue, etc.). We also introduce another method to find profitable targets on vasculature, which is called "Vascular proteomic technique". Our results suggest that this method for the rapid generation of Mabs to proteins may be very useful in proteomics-based research as well as in clinical applications.

  20. Performance of Traditional and Molecular Methods for Detecting Biological Agents in Drinking Water

    USGS Publications Warehouse

    Francy, Donna S.; Bushon, Rebecca N.; Brady, Amie M.G.; Bertke, Erin E.; Kephart, Christopher M.; Likirdopulos, Christina A.; Mailot, Brian E.; Schaefer, Frank W.; Lindquist, H.D. Alan

    2009-01-01

    To reduce the impact from a possible bioterrorist attack on drinking-water supplies, analytical methods are needed to rapidly detect the presence of biological agents in water. To this end, 13 drinking-water samples were collected at 9 water-treatment plants in Ohio to assess the performance of a molecular method in comparison to traditional analytical methods that take longer to perform. Two 100-liter samples were collected at each site during each sampling event; one was seeded in the laboratory with six biological agents - Bacillus anthracis (B. anthracis), Burkholderia cepacia (as a surrogate for Bu. pseudomallei), Francisella tularensis (F. tularensis), Salmonella Typhi (S. Typhi), Vibrio cholerae (V. cholerae), and Cryptospordium parvum (C. parvum). The seeded and unseeded samples were processed by ultrafiltration and analyzed by use of quantiative polymerase chain reaction (qPCR), a molecular method, and culture methods for bacterial agents or the immunomagnetic separation/fluorescent antibody (IMS/FA) method for C. parvum as traditional methods. Six replicate seeded samples were also processed and analyzed. For traditional methods, recoveries were highly variable between samples and even between some replicate samples, ranging from below detection to greater than 100 percent. Recoveries were significantly related to water pH, specific conductance, and dissolved organic carbon (DOC) for all bacteria combined by culture methods, but none of the water-quality characteristics tested were related to recoveries of C. parvum by IMS/FA. Recoveries were not determined by qPCR because of problems in quantifying organisms by qPCR in the composite seed. Instead, qPCR results were reported as detected, not detected (no qPCR signal), or +/- detected (Cycle Threshold or 'Ct' values were greater than 40). Several sample results by qPCR were omitted from the dataset because of possible problems with qPCR reagents, primers, and probes. For the remaining 14 qPCR results (including some replicate samples), F. tularensis and V. cholerae were detected in all samples after ultrafiltration, B. anthracis was detected in 13 and +/- detected in 1 sample, and C. parvum was detected in 9 and +/- detected in 4 samples. Bu. cepacia was detected in nine samples, +/- detected in two samples, and not detected in three samples (for two out of three samples not detected, a different strain was used). The qPCR assay for V. cholerae provided two false positive - but late - signals in one unseeded sample. Numbers found by qPCR after ultrafiltration were significantly or nearly significantly related to those found by traditional methods for B. anthracis, F. tularensis, and V. cholerae but not for Bu. cepacia and C. parvum. A qPCR assay for S. Typhi was not available. The qPCR method can be used to rapidly detect B. anthracis, F. tularensis, and V. cholerae with some certainty in drinking-water samples, but additional work would be needed to optimize and test qPCR for Bu. cepacia and C. parvum and establish relations to traditional methods. The specificity for the V. cholerae assay needs to be further investigated. Evidence is provided that ultrafiltration and qPCR are promising methods to rapidly detect biological agents in the Nation's drinking-water supplies and thus reduce the impact and consequences from intentional bioterrorist events. To our knowledge, this is the first study to compare the use of traditional and qPCR methods to detect biological agents in large-volume drinking-water samples.

  1. Detection of Bordetella pertussis by rapid-cycle PCR and colorimetric microwell hybridization.

    PubMed Central

    Buck, G E

    1996-01-01

    The use of rapid-cycle PCR combined with colorimetric microwell hybridization for detecting Bordetella pertussis was investigated. Rapid cycling was performed with an air thermocycler (model 1605; Idaho Technology, Idaho Falls, Idaho). Although the instrument was originally designed to be used with capillary tubes, an adapter that allows this instrument to be used with PCR tubes has recently been introduced. Because of the low heat capacity of air, the thermocycler has rapid transition rates between temperatures. The combination of a rapid temperature transition rate, small sample volume (10 microliters), and overshooting or undershooting of the temperature set points allowed the cycles to be reduced to 5 s for denaturation and 10 s for extension and annealing. Thus, the amplification could be completed in a total of approximately 35 min. Amplified DNA was detected with biotin-labeled primers and by hybridization to a capture probe immobilized in microwell plates. When simulated clinical specimens consisting of pooled nasopharyngeal washes with known numbers of B. pertussis organisms were examined by this procedure, as little as one organism per 5 microliters of sample could be detected. Six nasopharyngeal aspirates or washes from culture-positive patients were positive by PCR, as were two of seven specimens obtained from patients that were negative by culture and direct fluorescent-antibody assay. The two patients who were PCR positive but culture and direct fluorescent-antibody assay negative had clinical disease compatible with pertussis. This method appears to be a sensitive, convenient means of detecting B. pertussis in clinical specimens. The total time required for specimen processing, amplification, and detection is about 2.5 h. PMID:8735080

  2. Rapid antigen tests for dengue virus serotypes and Zika virus in patient serum.

    PubMed

    Bosch, Irene; de Puig, Helena; Hiley, Megan; Carré-Camps, Marc; Perdomo-Celis, Federico; Narváez, Carlos F; Salgado, Doris M; Senthoor, Dewahar; O'Grady, Madeline; Phillips, Elizabeth; Durbin, Ann; Fandos, Diana; Miyazaki, Hikaru; Yen, Chun-Wan; Gélvez-Ramírez, Margarita; Warke, Rajas V; Ribeiro, Lucas S; Teixeira, Mauro M; Almeida, Roque P; Muñóz-Medina, José E; Ludert, Juan E; Nogueira, Mauricio L; Colombo, Tatiana E; Terzian, Ana C B; Bozza, Patricia T; Calheiros, Andrea S; Vieira, Yasmine R; Barbosa-Lima, Giselle; Vizzoni, Alexandre; Cerbino-Neto, José; Bozza, Fernando A; Souza, Thiago M L; Trugilho, Monique R O; de Filippis, Ana M B; de Sequeira, Patricia C; Marques, Ernesto T A; Magalhaes, Tereza; Díaz, Francisco J; Restrepo, Berta N; Marín, Katerine; Mattar, Salim; Olson, Daniel; Asturias, Edwin J; Lucera, Mark; Singla, Mohit; Medigeshi, Guruprasad R; de Bosch, Norma; Tam, Justina; Gómez-Márquez, Jose; Clavet, Charles; Villar, Luis; Hamad-Schifferli, Kimberly; Gehrke, Lee

    2017-09-27

    The recent Zika virus (ZIKV) outbreak demonstrates that cost-effective clinical diagnostics are urgently needed to detect and distinguish viral infections to improve patient care. Unlike dengue virus (DENV), ZIKV infections during pregnancy correlate with severe birth defects, including microcephaly and neurological disorders. Because ZIKV and DENV are related flaviviruses, their homologous proteins and nucleic acids can cause cross-reactions and false-positive results in molecular, antigenic, and serologic diagnostics. We report the characterization of monoclonal antibody pairs that have been translated into rapid immunochromatography tests to specifically detect the viral nonstructural 1 (NS1) protein antigen and distinguish the four DENV serotypes (DENV1-4) and ZIKV without cross-reaction. To complement visual test analysis and remove user subjectivity in reading test results, we used image processing and data analysis for data capture and test result quantification. Using a 30-μl serum sample, the sensitivity and specificity values of the DENV1-4 tests and the pan-DENV test, which detects all four dengue serotypes, ranged from 0.76 to 1.00. Sensitivity/specificity for the ZIKV rapid test was 0.81/0.86, respectively, using a 150-μl serum input. Serum ZIKV NS1 protein concentrations were about 10-fold lower than corresponding DENV NS1 concentrations in infected patients; moreover, ZIKV NS1 protein was not detected in polymerase chain reaction-positive patient urine samples. Our rapid immunochromatography approach and reagents have immediate application in differential clinical diagnosis of acute ZIKV and DENV cases, and the platform can be applied toward developing rapid antigen diagnostics for emerging viruses. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  3. Loop-mediated isothermal amplification assay for rapid detection of Streptococcus agalactiae (group B streptococcus) in vaginal swabs - a proof of concept study.

    PubMed

    McKenna, James Patrick; Cox, Ciara; Fairley, Derek John; Burke, Rachael; Shields, Michael D; Watt, Alison; Coyle, Peter Valentine

    2017-03-01

    Neonatal sepsis caused by Streptococcus agalactiae [group B streptococcus (GBS)] is a life-threatening condition, which is preventable if colonized mothers are identified and given antibiotic prophylaxis during labour. Conventional culture is time consuming and unreliable, and many available non-culture diagnostics are too complex to implement routinely at point of care. Loop-mediated isothermal amplification (LAMP) is a method that, enables the rapid and specific detection of target nucleic acid sequences in clinical materials without the requirement for extensive sample preparation. A prototype LAMP assay targeting GBS sip gene is described. The assay was 100 % specific for GBS, with a limit of detection of 14 genome copies per reaction. The clinical utility of the LAMP assay for rapid direct molecular detection of GBS was determined by testing a total of 157 vaginal swabs with minimal sample processing using a rapid lysis solution. Compared to a reference quantitative real-time PCR assay, the direct LAMP protocol had a sensitivity and specificity of 95.4 and 100 %, respectively, with positive and negative predictive values of 100 and 98.3 %, respectively. Positive and negative likelihood ratios were infinity and 0.05, respectively. The direct LAMP method required a mean time of 45 min from the receipt of a swab to generation of a confirmed result, compared to 2 h 30 min for the reference quantitative real-time PCR test. The direct LAMP protocol described is easy to perform, facilitating rapid and accurate detection of GBS in vaginal swabs. This test has a potential for use at point of care.

  4. Raman study of local ordering processes of solid n-alkanes

    NASA Astrophysics Data System (ADS)

    Hacura, A.; Zimnicka, B.; Wrzalik, R.

    2016-02-01

    The microphase separation of n-alkanes with different chain length was investigated by Raman spectroscopy for binary mixture rapidly quenched from the melt. The process was observed as a function of time. The first several minutes after solidification were crucial for the demixing process. For a few weeks old sample the orientational order parameters and were calculated based on the analysis of polarized spectra recorded in the area of the formed domains. The measured values are significantly greater than zero (from 0.17 to 0.32), which indicates the mutual parallel arrangement of the molecules in the domains composed of n-alkanes of the same chain length.

  5. Comparative Analysis of Structural Responses of Rat Subcutaneous Fat on the Implantation of Samples of Polymethyl Methacrylate with Hydrophobic and Hydrophilic Surface.

    PubMed

    Kudasova, E O; Vlasova, L F; Semenov, D E; Lushnikova, E L

    2017-03-01

    Morphological analysis of the subcutaneous fat was performed in rats after subcutaneous implantation of basic dental plastic materials with different hydrophobic and hydrophilic properties. It was shown that subcutaneous implantation of dental plastics with mostly hydrophobic surface and low biocompatibility induced destructive and inflammatory processes of various intensities, sometimes with allergic component; morphological signs of processes persisted for 6 weeks. Modification of basic plastics using glow-discharge plasma and enhancement of their hydrophilicity and biocompatibility significantly reduced the intensity of destructive and inflammatory processes and ensured more rapid (in 2 weeks) repair of the destroyed tissues with the formation of fibrous capsule around the implant.

  6. Fully Automated Sample Preparation for Ultrafast N-Glycosylation Analysis of Antibody Therapeutics.

    PubMed

    Szigeti, Marton; Lew, Clarence; Roby, Keith; Guttman, Andras

    2016-04-01

    There is a growing demand in the biopharmaceutical industry for high-throughput, large-scale N-glycosylation profiling of therapeutic antibodies in all phases of product development, but especially during clone selection when hundreds of samples should be analyzed in a short period of time to assure their glycosylation-based biological activity. Our group has recently developed a magnetic bead-based protocol for N-glycosylation analysis of glycoproteins to alleviate the hard-to-automate centrifugation and vacuum-centrifugation steps of the currently used protocols. Glycan release, fluorophore labeling, and cleanup were all optimized, resulting in a <4 h magnetic bead-based process with excellent yield and good repeatability. This article demonstrates the next level of this work by automating all steps of the optimized magnetic bead-based protocol from endoglycosidase digestion, through fluorophore labeling and cleanup with high-throughput sample processing in 96-well plate format, using an automated laboratory workstation. Capillary electrophoresis analysis of the fluorophore-labeled glycans was also optimized for rapid (<3 min) separation to accommodate the high-throughput processing of the automated sample preparation workflow. Ultrafast N-glycosylation analyses of several commercially relevant antibody therapeutics are also shown and compared to their biosimilar counterparts, addressing the biological significance of the differences. © 2015 Society for Laboratory Automation and Screening.

  7. Enumeration and rapid identification of yeasts during extraction processes of extra virgin olive oil in Tuscany.

    PubMed

    Mari, Eleonora; Guerrini, Simona; Granchi, Lisa; Vincenzini, Massimo

    2016-06-01

    The aim of this study was to evaluate the occurrence of yeast populations during different olive oil extraction processes, carried out in three consecutive years in Tuscany (Italy), by analysing crushed pastes, kneaded pastes, oil from decanter and pomaces. The results showed yeast concentrations ranging between 10(3) and 10(5) CFU/g or per mL. Seventeen dominant yeast species were identified by random amplified polymorphic DNA with primer M13 and their identification was confirmed by restriction fragments length polymorphism of ribosomal internal transcribed spacer and sequencing rRNA genes. The isolation frequencies of each species in the collected samples pointed out that the occurrence of the various yeast species in olive oil extraction process was dependent not only on the yeasts contaminating the olives but also on the yeasts colonizing the plant for oil extraction. In fact, eleven dominant yeast species were detected from the washed olives, but only three of them were also found in oil samples at significant isolation frequency. On the contrary, the most abundant species in oil samples, Yamadazyma terventina, did not occur in washed olive samples. These findings suggest a phenomenon of contamination of the plant for oil extraction that selects some yeast species that could affect the quality of olive oil.

  8. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    PubMed

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Microgravity

    NASA Image and Video Library

    1995-09-15

    Large Isothermal Furnace (LIF) was flown on a mission in cooperation with the National Space Development Agency (NASDA) of Japan. LIF is a vacuum-heating furnace designed to heat large samples uniformly. The furnace consists of a sample container and heating element surrounded by a vacuum chamber. A crewmemeber will insert a sample cartridge into the furnace. The furnace will be activated and operations will be controlled automatically by a computer in response to an experiment number entered on the control panel. At the end of operations, helium will be discharged into the furnace, allowing cooling to start. Cooling will occur through the use of a water jacket while rapid cooling of samples can be accomplished through a controlled flow of helium. Data from experiments will help scientists better understand this important process which is vital to the production of high-quality semiconductor crystals.

  10. Alpha spectrometric characterization of process-related particle size distributions from active particle sampling at the Los Alamos National Laboratory uranium foundry

    NASA Astrophysics Data System (ADS)

    Plionis, A. A.; Peterson, D. S.; Tandon, L.; LaMont, S. P.

    2010-03-01

    Uranium particles within the respirable size range pose a significant hazard to the health and safety of workers. Significant differences in the deposition and incorporation patterns of aerosols within the respirable range can be identified and integrated into sophisticated health physics models. Data characterizing the uranium particle size distribution resulting from specific foundry-related processes are needed. Using personal air sampling cascade impactors, particles collected from several foundry processes were sorted by activity median aerodynamic diameter onto various Marple substrates. After an initial gravimetric assessment of each impactor stage, the substrates were analyzed by alpha spectrometry to determine the uranium content of each stage. Alpha spectrometry provides rapid non-distructive isotopic data that can distinguish process uranium from natural sources and the degree of uranium contribution to the total accumulated particle load. In addition, the particle size bins utilized by the impactors provide adequate resolution to determine if a process particle size distribution is: lognormal, bimodal, or trimodal. Data on process uranium particle size values and distributions facilitate the development of more sophisticated and accurate models for internal dosimetry, resulting in an improved understanding of foundry worker health and safety.

  11. Shrinking of silicon nanocrystals embedded in an amorphous silicon oxide matrix during rapid thermal annealing in a forming gas atmosphere

    NASA Astrophysics Data System (ADS)

    van Sebille, M.; Fusi, A.; Xie, L.; Ali, H.; van Swaaij, R. A. C. M. M.; Leifer, K.; Zeman, M.

    2016-09-01

    We report the effect of hydrogen on the crystallization process of silicon nanocrystals embedded in a silicon oxide matrix. We show that hydrogen gas during annealing leads to a lower sub-band gap absorption, indicating passivation of defects created during annealing. Samples annealed in pure nitrogen show expected trends according to crystallization theory. Samples annealed in forming gas, however, deviate from this trend. Their crystallinity decreases for increased annealing time. Furthermore, we observe a decrease in the mean nanocrystal size and the size distribution broadens, indicating that hydrogen causes a size reduction of the silicon nanocrystals.

  12. Rapid detection of bacteria with miniaturized pyrolysis-gas chromatographic analysis

    NASA Astrophysics Data System (ADS)

    Mowry, Curtis; Morgan, Catherine H.; Baca, Quentin; Manginell, Ronald P.; Kottenstette, Richard J.; Lewis, Patrick; Frye-Mason, Gregory C.

    2002-02-01

    Rapid detection and identification of bacteria and other pathogens is important for many civilian and military applications. The profiles of biological markers such as fatty acids can be used to characterize biological samples or to distinguish bacteria at the gram-type, genera, and even species level. Common methods for whole cell bacterial analysis are neither portable nor rapid, requiring lengthy, labor intensive sample preparation and bench-scale instrumentation. These methods chemically derivatize fatty acids to produce more volatile fatty acid methyl esters (FAMEs) that can be separated and analyzed by a gas chromatograph (GC)/mass spectrometer. More recent publications demonstrate decreased sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis/derivatization. Ongoing development of miniaturized pyrolysis/GC instrumentation by this department capitalizes on Sandia advances in the field of microfabricated chemical analysis systems ((mu) ChemLab). Microdevices include rapidly heated stages capable of pyrolysis or sample concentration, gas chromatography columns, and surface acoustic wave (SAW) sensor arrays. We will present results demonstrating the capabilities of these devices toward fulfilling the goal of portable, rapid detection and early warning of the presence of pathogens in air or water.

  13. A novel colorimetric assay for rapid detection of cysteine and Hg²⁺ based on gold clusters.

    PubMed

    Wang, Yi-Wei; Tang, Shurong; Yang, Huang-Hao; Song, Hongbo

    2016-01-01

    Inhibition and recovery of the catalytic activity of bovine serum albumin-capped gold nanoclusters (BSA-AuNCs) is observed for the first time by introduction of cysteine and Hg(2+). The prepared BSA-AuNCs possess highly intrinsic peroxidase-like activity. It can catalyze the oxidation of 3, 3, 5, 5-tetramethylbenzidine by H2O2 to produce a blue colored product. Based on this phenomenon, a new colorimetric assay for rapid, selective and sensitive detection of cysteine and Hg(2+) in aqueous solution has been demonstrated. The interaction process between target molecule and BSA-AuNCs is very fast, so that the whole test can be completed within ten minutes. Moreover, the fabricated colorimetric sensor is simple and cost-effective, without the need of nucleic acid based recognition element and complicated washing, separation and labeling process, thus holds great promise for routine analysis of cysteine and Hg(2+) in real samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Cryopreservation of boar semen. III: Ultrastructure of boar spermatozoa frozen ultra-rapidly at various stages of conventional freezing and thawing.

    PubMed

    Bwanga, C O; Ekwall, H; Rodriguez-Martinez, H

    1991-01-01

    Ejaculated boar spermatozoa subjected to a conventional freezing and thawing process, were ultra-rapidly fixed, freeze-substituted and examined by electron microscopy to monitor the presence of real or potential intracellular ice and the degree of cell protection attained with the different extenders used during the process. Numerous ice crystal marks representing the degree of hydration of the cells were located in the perinuclear space of those spermatozoa not in proper contact with the extender containing glycerol (i.e. prior to freezing). The spermatozoa which were in proper contact with the extenders presented a high degree of preservation of the acrosomes, plasma membranes as well as the nuclear envelopes. No ice marks were detected in acrosomes before thawing, indicating that the conventional assayed cryopreservation method provided a good protection against cryoinjury. The presence of acrosomal changes (internal vesiculization, hydration and swelling) in thawed samples however, raises serious questions about the thawing procedure employed.

  15. The coffee-machine bacteriome: biodiversity and colonisation of the wasted coffee tray leach

    PubMed Central

    Vilanova, Cristina; Iglesias, Alba; Porcar, Manuel

    2015-01-01

    Microbial communities are ubiquitous in both natural and artificial environments. However, microbial diversity is usually reduced under strong selection pressures, such as those present in habitats rich in recalcitrant or toxic compounds displaying antimicrobial properties. Caffeine is a natural alkaloid present in coffee, tea and soft drinks with well-known antibacterial properties. Here we present the first systematic analysis of coffee machine-associated bacteria. We sampled the coffee waste reservoir of ten different Nespresso machines and conducted a dynamic monitoring of the colonization process in a new machine. Our results reveal the existence of a varied bacterial community in all the machines sampled, and a rapid colonisation process of the coffee leach. The community developed from a pioneering pool of enterobacteria and other opportunistic taxa to a mature but still highly variable microbiome rich in coffee-adapted bacteria. The bacterial communities described here, for the first time, are potential drivers of biotechnologically relevant processes including decaffeination and bioremediation. PMID:26592442

  16. The coffee-machine bacteriome: biodiversity and colonisation of the wasted coffee tray leach.

    PubMed

    Vilanova, Cristina; Iglesias, Alba; Porcar, Manuel

    2015-11-23

    Microbial communities are ubiquitous in both natural and artificial environments. However, microbial diversity is usually reduced under strong selection pressures, such as those present in habitats rich in recalcitrant or toxic compounds displaying antimicrobial properties. Caffeine is a natural alkaloid present in coffee, tea and soft drinks with well-known antibacterial properties. Here we present the first systematic analysis of coffee machine-associated bacteria. We sampled the coffee waste reservoir of ten different Nespresso machines and conducted a dynamic monitoring of the colonization process in a new machine. Our results reveal the existence of a varied bacterial community in all the machines sampled, and a rapid colonisation process of the coffee leach. The community developed from a pioneering pool of enterobacteria and other opportunistic taxa to a mature but still highly variable microbiome rich in coffee-adapted bacteria. The bacterial communities described here, for the first time, are potential drivers of biotechnologically relevant processes including decaffeination and bioremediation.

  17. Tephra Sedimentation from a Short-term Wind-affected Volcanic Plume of the 8 October 2016 Aso Nakadake Eruption, Japan

    NASA Astrophysics Data System (ADS)

    Tsuji, T.; Nishizaka, N.; Onishi, K.

    2017-12-01

    Sedimentation processes during explosive volcanic eruptions can be constrained based on detailed analysis of grain-size variation of tephra deposits. Especially, an accurate description of the amount of fine particles has also significant implications for the assessment of specific tephra hazards. Grain size studies for single short-term eruption has advantage to contribute understanding the sedimentation processes because it is simple compared to long-lasting eruption. The 2016 Aso Nakadake eruption, Japan represents an ideal for the study of short-term eruptions thanks to an accurate investigation. Then, we investigate the grain size variation with distance from the vent and sedimentological features of the deposit to discuss the sedimentation processes of the tephra fragments. The eruption provided pyroclastic flow deposit and fallout tephra which distributed NE to ENE direction from the vent. The deposits between 4 and 20 km from vent consist of fine-coated lapilli to coarse ash, ash pellet and mud droplet in ascending degree. The samples are lapilli-bearing within 20 km from vent and those outside of 20 km mainly consist of ash particles. Detailed analyses of individual samples highlight a rapid decay of maximum and mean grain size for the deposit from proximal to distal. The decay trend of maximum grain-size is approximated by three segments of exponential curves with two breaks-in-slope at 10 and 40 km from vent. Most of the sampled deposits are characterized by bimodal grain-size distributions, with the modes of the coarse subpopulation decreasing with distance from vent and those of the fine subpopulation being mostly stable. The fine subpopulation has been interpreted as being mostly associated with size-selective sedimentation processes (e.g., particle aggregation) confirmed by the existence of fine-coated particles, ash pellet and mud droplet. As the fine-coated particles generally have a higher terminal velocity than the individual constituent particles, those could be related with the rapid decrease of maximum grain-size with distance from vent at proximal area. Further detail grain-size analyses and theoretical studies can be contributed to understand the effect of fine ash aggregation on sedimentation processes quantitatively.

  18. Laboratory Investigation on Physical and Mechanical Properties of Granite After Heating and Water-Cooling Treatment

    NASA Astrophysics Data System (ADS)

    Zhang, Fan; Zhao, Jianjian; Hu, Dawei; Skoczylas, Frederic; Shao, Jianfu

    2018-03-01

    High-temperature treatment may cause changes in physical and mechanical properties of rocks. Temperature changing rate (heating, cooling and both of them) plays an important role in those changes. Thermal conductivity tests, ultrasonic pulse velocity tests, gas permeability tests and triaxial compression tests are performed on granite samples after a heating and rapid cooling treatment in order to characterize the changes in physical and mechanical properties. Seven levels of temperature (from 25 to 900 °C) are used. It is found that the physical and mechanical properties of granite are significantly deteriorated by the thermal treatment. The porosity shows a significant increase from 1.19% at the initial state to 6.13% for samples heated to 900 °C. The increase in porosity is mainly due to three factors: (1) a large number of microcracks caused by the rapid cooling rate; (2) the mineral transformation of granite through high-temperature heating and water-cooling process; (3) the rapid cooling process causes the mineral particles to weaken. As the temperature of treatment increases, the thermal conductivity and P-wave velocity decrease while the gas permeability increases. Below 200 °C, the elastic modulus and cohesion increase with temperature increasing. Between 200 and 500 °C, the elastic modulus and cohesion have no obvious change with temperature. Beyond 500 °C, as the temperature increases, the elastic modulus and cohesion obviously decrease and the decreasing rate becomes slower with the increase in confining pressure. Poisson's ratio and internal frictional coefficient have no obvious change as the temperature increases. Moreover, there is a transition from a brittle to ductile behavior when the temperature becomes high. At 900 °C, the granite shows an obvious elastic-plastic behavior.

  19. A high-throughput core sampling device for the evaluation of maize stalk composition

    PubMed Central

    2012-01-01

    Background A major challenge in the identification and development of superior feedstocks for the production of second generation biofuels is the rapid assessment of biomass composition in a large number of samples. Currently, highly accurate and precise robotic analysis systems are available for the evaluation of biomass composition, on a large number of samples, with a variety of pretreatments. However, the lack of an inexpensive and high-throughput process for large scale sampling of biomass resources is still an important limiting factor. Our goal was to develop a simple mechanical maize stalk core sampling device that can be utilized to collect uniform samples of a dimension compatible with robotic processing and analysis, while allowing the collection of hundreds to thousands of samples per day. Results We have developed a core sampling device (CSD) to collect maize stalk samples compatible with robotic processing and analysis. The CSD facilitates the collection of thousands of uniform tissue cores consistent with high-throughput analysis required for breeding, genetics, and production studies. With a single CSD operated by one person with minimal training, more than 1,000 biomass samples were obtained in an eight-hour period. One of the main advantages of using cores is the high level of homogeneity of the samples obtained and the minimal opportunity for sample contamination. In addition, the samples obtained with the CSD can be placed directly into a bath of ice, dry ice, or liquid nitrogen maintaining the composition of the biomass sample for relatively long periods of time. Conclusions The CSD has been demonstrated to successfully produce homogeneous stalk core samples in a repeatable manner with a throughput substantially superior to the currently available sampling methods. Given the variety of maize developmental stages and the diversity of stalk diameter evaluated, it is expected that the CSD will have utility for other bioenergy crops as well. PMID:22548834

  20. MSFC Electrostatic Levitator (ESL) Rapid Quench System

    NASA Technical Reports Server (NTRS)

    SanSoucie, Michael P.; Craven, Paul D.; Rogers, Jan R.

    2014-01-01

    The NASA Marshall Space Flight Center (MSFC) Electrostatic Levitator (ESL) Laboratory is a unique facility for investigators studying high-temperature materials. The laboratory boasts two levitators in which samples can be levitated, heated, melted, undercooled, and resolidified, all without the interference of a container or data-gathering instrument. The ESL main chamber has been upgraded with the addition of a rapid quench system. This system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals. Up to 8 quench vessels can be loaded into the quench wheel, which is indexed with LabVIEW control software. This allows up to 8 samples to be rapidly quenched before having to open the chamber. The system has been tested successfully on several zirconium samples. Future work will be done with other materials using different quench mediums. Microstructural analysis will also be done on successfully quench samples.

  1. Rapid method to determine 89Sr/ 90Sr in large concrete samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.

    Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g -1. The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90Sr from 5-10 g concrete samples. When, the 89Sr/ 90Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90Sr measured, and then 90Sr determined via 90Y separatedmore » after a period of ingrowth. Another approach allows the immediate determination of 90Sr in 10 g concrete aliquots without waiting for 90Y ingrowth, in instances where the shorter lived 89Sr is unlikely to be encountered.« less

  2. Rapid method to determine 89Sr/ 90Sr in large concrete samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; ...

    2016-03-24

    Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g -1. The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90Sr from 5-10 g concrete samples. When, the 89Sr/ 90Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90Sr measured, and then 90Sr determined via 90Y separatedmore » after a period of ingrowth. Another approach allows the immediate determination of 90Sr in 10 g concrete aliquots without waiting for 90Y ingrowth, in instances where the shorter lived 89Sr is unlikely to be encountered.« less

  3. Rapid detection of terbufos in stomach contents using desorption electrospray ionization mass spectrometry.

    PubMed

    Wilson, Christina R; Mulligan, Christopher C; Strueh, Kurt D; Stevenson, Gregory W; Hooser, Stephen B

    2014-05-01

    Desorption electrospray ionization mass spectrometry (DESI-MS) is an emerging analytical technique that permits the rapid and direct analysis of biological or environmental samples under ambient conditions. Highlighting the versatility of this technique, DESI-MS has been used for the rapid detection of illicit drugs, chemical warfare agents, agricultural chemicals, and pharmaceuticals from a variety of sample matrices. In diagnostic veterinary toxicology, analyzing samples using traditional analytical instrumentation typically includes extensive sample extraction procedures, which can be time consuming and labor intensive. Therefore, efforts to expedite sample analyses are a constant goal for diagnostic toxicology laboratories. In the current report, DESI-MS was used to directly analyze stomach contents from a dog exposed to the organophosphate insecticide terbufos. The total DESI-MS analysis time required to confirm the presence of terbufos and diagnose organophosphate poisoning in this case was approximately 5 min. This highlights the potential of this analytical technique in the field of veterinary toxicology for the rapid diagnosis and detection of toxicants in biological samples. © 2014 The Author(s).

  4. Rapid Analysis of Trace Drugs and Metabolites Using a Thermal Desorption DART-MS Configuration.

    PubMed

    Sisco, Edward; Forbes, Thomas P; Staymates, Matthew E; Gillen, Greg

    2016-01-01

    The need to analyze trace narcotic samples rapidly for screening or confirmatory purposes is of increasing interest to the forensic, homeland security, and criminal justice sectors. This work presents a novel method for the detection and quantification of trace drugs and metabolites off of a swipe material using a thermal desorption direct analysis in real time mass spectrometry (TD-DART-MS) configuration. A variation on traditional DART, this configuration allows for desorption of the sample into a confined tube, completely independent of the DART source, allowing for more efficient and thermally precise analysis of material present on a swipe. Over thirty trace samples of narcotics, metabolites, and cutting agents deposited onto swipes were rapidly differentiated using this methodology. The non-optimized method led to sensitivities ranging from single nanograms to hundreds of picograms. Direct comparison to traditional DART with a subset of the samples highlighted an improvement in sensitivity by a factor of twenty to thirty and an increase in reproducibility sample to sample from approximately 45 % RSD to less than 15 % RSD. Rapid extraction-less quantification was also possible.

  5. Metal-organic framework MIL-101 as sorbent based on double-pumps controlled on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of flavonoids in environmental water samples.

    PubMed

    Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang

    2016-10-01

    A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Stability of bisphenol A, triethylene-glycol dimethacrylate, and bisphenol A dimethacrylate in whole saliva.

    PubMed

    Atkinson, Jane C; Diamond, Francis; Eichmiller, Frederick; Selwitz, Robert; Jones, Gordon

    2002-03-01

    This study investigated the stability of compounds of dental sealant materials in a salivary matrix. Various amounts of bisphenol A (BPA), bisphenol A dimethacrylate (BIS-DMA) or triethylene-glycol dimethacrylate (TEGDMA) were added to whole salivary samples, and stored at -70 degrees C or -20 degrees C for up to 4 months. In other experiments, four separate whole salivary or water samples with BIS-DMA (200 ng/ml) were incubated for 0, 1, 2, 4 or 24h at 37 degrees C. Levels of analytes were determined by capillary gas chromatography/mass spectrophotometry (GC/MS) and high-performance liquid chromatography (HPLC). BPA was stable under all tested conditions. Samples originally containing BIS-DMA had high levels of BPA and almost no BIS-DMA after 4 months at -20 degrees C. Salivary samples incubated at 37 degrees C originally containing only BIS-DMA (200 ng/ml) demonstrated rapid decreases of BIS-DMA and increases of BPA. By 24h, the mean BIS-DMA concentration fell to 21.8 (25) ng/ml, while BPA increased to 100 (48) ng/ml. Only slight decreases in BIS-DMA and no BPA were present in the water samples incubated at 37 degrees C. BPA, BIS-DMA, and TEGDMA were stable if salivary samples were stored at -70 degrees C. Acidification of salivary samples prevented the breakdown of BIS-DMA. BIS-DMA is converted rapidly to BPA in the presence of whole saliva. This could account for the findings of BPA in clinical samples collected after the placement of certain sealant products. Decreasing salivary pH and temperature can slow this process and this method should be used for clinical studies of salivary BPA leached from restorative materials.

  7. Evolution of concentration-discharge relations revealed by high frequency diurnal sampling of stream water during spring snowmelt

    NASA Astrophysics Data System (ADS)

    Olshansky, Y.; White, A. M.; Thompson, M.; Moravec, B. G.; McIntosh, J. C.; Chorover, J.

    2017-12-01

    Concentration discharge (C-Q) relations contain potentially important information on critical zone (CZ) processes including: weathering reactions, water flow paths and nutrient export. To examine the C-Q relations in a small (3.3 km2) headwater catchment - La Jara Creek located in the Jemez River Basin Critical Zone Observatory, daily, diurnal stream water samples were collected during spring snow melt 2017, from two flumes located in outlets of the La Jara Creek and a high elevation zero order basin within this catchment. Previous studies from this site (McIntosh et al., 2017) suggested that high frequency sampling was needed to improve our interpretation of C-Q relations. The dense sampling covered two ascending and two descending limbs of the snowmelt hydrograph, from March 1 to May 15, 2017. While Na showed inverse correlation (dilution) with discharge, most other solutes (K, Mg, Fe, Al, dissolved organic carbon) exhibited positive (concentration) or chemostatic trends (Ca, Mn, Si, dissolved inorganic carbon and dissolved nitrogen). Hysteresis in the C-Q relation was most pronounced for bio-cycled cations (K, Mg) and for Fe, which exhibited concentration during the first ascending limb followed by a chemostatic trend. A pulsed increase in Si concentration immediately after the first ascending limb in both flumes suggests mixing of deep groundwater with surface water. A continual increase in Ge/Si concentrations followed by a rapid decrease after the second rising limb may suggest a fast transition between soil water to ground water dominating the stream flow. Fourier transform infrared spectroscopy of selected samples across the hydrograph demonstrated pronounced changes in dissolved organic matter molecular composition with the advancement of the spring snow melt. X-ray micro-spectroscopy of colloidal material isolated from the collected water samples indicated a significant role for organic matter in the transport of inorganic colloids. Analyses of high frequency diurnal sampling greatly improve our ability to probe rapid CZ changes occurring during spring snowmelt, and provide useful information for evaluation and modeling of CZ processes in other snow melt dominated regions.

  8. Quasi-metagenomics and realtime sequencing aided detection and subtyping of Salmonella enterica from food samples.

    PubMed

    Hyeon, Ji-Yeon; Li, Shaoting; Mann, David A; Zhang, Shaokang; Li, Zhen; Chen, Yi; Deng, Xiangyu

    2017-12-01

    Metagenomics analysis of food samples promises isolation-independent detection and subtyping of foodborne bacterial pathogens in a single workflow. Selective concentration of Salmonella genomic DNA through immunomagnetic separation (IMS) and multiple displacement amplification (MDA) were shown to shorten culture enrichment of Salmonella -spiked raw chicken breast samples by over 12 hours while permitting serotyping and high-fidelity single nucleotide polymorphisms (SNP) typing of the pathogen using short shotgun sequencing reads. The herein termed quasi-metagenomics approach was evaluated on Salmonella -spiked lettuce and black peppercorn samples as well as retail chicken parts naturally contaminated with different serotypes of Salmonella. Between 8 and 24 h culture enrichment was required for detecting and subtyping naturally occurring Salmonella from unspiked chicken parts compared with 4 to 12 h culture enrichment when Salmonella -spiked food samples were analyzed, indicating the likely need for longer culture enrichment to revive low levels of stressed or injured Salmonella cells in food. Further acceleration of the workflow was achieved by real-time nanopore sequencing. After 1.5 hours of analysis on a potable sequencer, sufficient data were generated from sequencing IMS-MDA product of a cultured-enriched lettuce sample to allow serotyping and robust phylogenetic placement of the inoculated isolate. Importance Both culture enrichment and next-generation sequencing remain to be time-consuming processes for food testing where rapid methods for pathogen detection are widely available. Our study demonstrated substantial acceleration of the respective process through IMS-MDA and real-time nanopore sequencing. In one example, the combined use of the two methods delivered a less than 24 h turnaround time from a Salmonella -contaminated lettuce sample to phylogenetic identification of the pathogen. Improved efficiency like this is important for further expanding the use of whole genome and metagenomics sequencing in microbial analysis of food. Our results suggest the potential of the quasi-metagenomics approach in areas where rapid detection and subtyping of foodborne pathogens is important, such as foodborne outbreak response and precision tracking and monitoring of foodborne pathogens in production environments and supply chains. Copyright © 2017 American Society for Microbiology.

  9. Experimental results of temperature response to stress change: An indication of the physics of earthquake rupture propagation

    NASA Astrophysics Data System (ADS)

    Lin, W.; Yang, X.; Tadai, O.; Zeng, X.; Yeh, E. C.; Yu, C.; Hatakeda, K.; Xu, H.; Xu, Z.

    2016-12-01

    As a result of the earthquake rupture propagation, stress on the earthquake fault and in the hanging wall and in the footwall coseismically drops. Based on the thermo-elasticity theory, the temperature of rocks may change associated with coseismic stress change at the same time as their elastic deformation. This coseismic temperature change is one of the physics of earthquake rupture propagation, however has not been noted and expressly addressed before. To understand this temperature issue, we conducted laboratory experiments to quantitatively investigate temperatures response of rocks to rapid stress change of various typical rocks. Consequently, we developed a hydrostatic compression experimental equipment for rock samples with a high resolution temperature measuring system. This enable us to rapidly load and/or unload the confining pressure. As experimental rock samples, we collected 15 representative rocks from various scientific drilling projects and outcrops of earthquake faults, and quarries in the world. The rock types include sandstone, siltstone, limestone, granite, basalt, tuff etc. Based on the classical thermo-elastic theory, a conventional relationship between the temperature change (dT) of rock samples and the confining pressure change (dP) in the hydrostatic compression system under adiabatic condition can be expressed as a linear function. Therefore, we can measure the adiabatic pressure derivative of temperature (dT/dP) directly by monitoring changes of rock sample temperature and confining pressure during the rapidly loading and unloading processes. As preliminary results of the experiments, the data of 15 rock samples showed that i) the adiabatic pressure derivative of temperature (dT/dP) of most rocks are about 1.5 6.2 mK/MPa; ii) the dT/dP of sedimentary rocks is larger than igneous and metamorphic rocks; iii) a good linear correlation between dT/dP and the rock's bulk modulus was recognized.

  10. A Lipid Extraction and Analysis Method for Characterizing Soil Microbes in Experiments with Many Samples

    PubMed Central

    Oates, Lawrence G.; Read, Harry W.; Gutknecht, Jessica L. M.; Duncan, David S.; Balser, Teri B.; Jackson, Randall D.

    2017-01-01

    Microbial communities are important drivers and regulators of ecosystem processes. To understand how management of ecosystems may affect microbial communities, a relatively precise but effort-intensive technique to assay microbial community composition is phospholipid fatty acid (PLFA) analysis. PLFA was developed to analyze phospholipid biomarkers, which can be used as indicators of microbial biomass and the composition of broad functional groups of fungi and bacteria. It has commonly been used to compare soils under alternative plant communities, ecology, and management regimes. The PLFA method has been shown to be sensitive to detecting shifts in microbial community composition. An alternative method, fatty acid methyl ester extraction and analysis (MIDI-FA) was developed for rapid extraction of total lipids, without separation of the phospholipid fraction, from pure cultures as a microbial identification technique. This method is rapid but is less suited for soil samples because it lacks an initial step separating soil particles and begins instead with a saponification reaction that likely produces artifacts from the background organic matter in the soil. This article describes a method that increases throughput while balancing effort and accuracy for extraction of lipids from the cell membranes of microorganisms for use in characterizing both total lipids and the relative abundance of indicator lipids to determine soil microbial community structure in studies with many samples. The method combines the accuracy achieved through PLFA profiling by extracting and concentrating soil lipids as a first step, and a reduction in effort by saponifying the organic material extracted and processing with the MIDI-FA method as a second step. PMID:28745639

  11. Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.

    PubMed

    Möser, J; Lips, K; Tseytlin, M; Eaton, G R; Eaton, S S; Schnegg, A

    2017-08-01

    X-band rapid-scan EPR was implemented on a commercially available Bruker ELEXSYS E580 spectrometer. Room temperature rapid-scan and continuous-wave EPR spectra were recorded for amorphous silicon powder samples. By comparing the resulting signal intensities the feasibility of performing quantitative rapid-scan EPR is demonstrated. For different hydrogenated amorphous silicon samples, rapid-scan EPR results in signal-to-noise improvements by factors between 10 and 50. Rapid-scan EPR is thus capable of improving the detection limit of quantitative EPR by at least one order of magnitude. In addition, we provide a recipe for setting up and calibrating a conventional pulsed and continuous-wave EPR spectrometer for rapid-scan EPR. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Rapid fingerprinting and classification of extra virgin olive oil by microjet sampling and extractive electrospray ionization mass spectrometry.

    PubMed

    Law, Wai Siang; Chen, Huan Wen; Balabin, Roman; Berchtold, Christian; Meier, Lukas; Zenobi, Renato

    2010-04-01

    Microjet sampling in combination with extractive electrospray ionization (EESI) mass spectrometry (MS) was applied to the rapid characterization and classification of extra virgin olive oil (EVOO) without any sample pretreatment. When modifying the composition of the primary ESI spray solvent, mass spectra of an identical EVOO sample showed differences. This demonstrates the capability of this technique to extract molecules with varying polarities, hence generating rich molecular information of the EVOO. Moreover, with the aid of microjet sampling, compounds of different volatilities (e.g.E-2-hexenal, trans-trans-2,4-heptadienal, tyrosol and caffeic acid) could be sampled simultaneously. EVOO data was also compared with that of other edible oils. Principal Component Analysis (PCA) was performed to discriminate EVOO and EVOO adulterated with edible oils. Microjet sampling EESI-MS was found to be a simple, rapid (less than 2 min analysis time per sample) and powerful method to obtain MS fingerprints of EVOO without requiring any complicated sample pretreatment steps.

  13. Stormbow: A Cloud-Based Tool for Reads Mapping and Expression Quantification in Large-Scale RNA-Seq Studies

    PubMed Central

    Zhao, Shanrong; Prenger, Kurt; Smith, Lance

    2013-01-01

    RNA-Seq is becoming a promising replacement to microarrays in transcriptome profiling and differential gene expression study. Technical improvements have decreased sequencing costs and, as a result, the size and number of RNA-Seq datasets have increased rapidly. However, the increasing volume of data from large-scale RNA-Seq studies poses a practical challenge for data analysis in a local environment. To meet this challenge, we developed Stormbow, a cloud-based software package, to process large volumes of RNA-Seq data in parallel. The performance of Stormbow has been tested by practically applying it to analyse 178 RNA-Seq samples in the cloud. In our test, it took 6 to 8 hours to process an RNA-Seq sample with 100 million reads, and the average cost was $3.50 per sample. Utilizing Amazon Web Services as the infrastructure for Stormbow allows us to easily scale up to handle large datasets with on-demand computational resources. Stormbow is a scalable, cost effective, and open-source based tool for large-scale RNA-Seq data analysis. Stormbow can be freely downloaded and can be used out of box to process Illumina RNA-Seq datasets. PMID:25937948

  14. Stormbow: A Cloud-Based Tool for Reads Mapping and Expression Quantification in Large-Scale RNA-Seq Studies.

    PubMed

    Zhao, Shanrong; Prenger, Kurt; Smith, Lance

    2013-01-01

    RNA-Seq is becoming a promising replacement to microarrays in transcriptome profiling and differential gene expression study. Technical improvements have decreased sequencing costs and, as a result, the size and number of RNA-Seq datasets have increased rapidly. However, the increasing volume of data from large-scale RNA-Seq studies poses a practical challenge for data analysis in a local environment. To meet this challenge, we developed Stormbow, a cloud-based software package, to process large volumes of RNA-Seq data in parallel. The performance of Stormbow has been tested by practically applying it to analyse 178 RNA-Seq samples in the cloud. In our test, it took 6 to 8 hours to process an RNA-Seq sample with 100 million reads, and the average cost was $3.50 per sample. Utilizing Amazon Web Services as the infrastructure for Stormbow allows us to easily scale up to handle large datasets with on-demand computational resources. Stormbow is a scalable, cost effective, and open-source based tool for large-scale RNA-Seq data analysis. Stormbow can be freely downloaded and can be used out of box to process Illumina RNA-Seq datasets.

  15. Droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling for simpler and faster PCR assay using wire-guided manipulations

    PubMed Central

    2012-01-01

    A computer numerical control (CNC) apparatus was used to perform droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling on a single superhydrophobic surface and a multi-chambered PCB heater. Droplets were manipulated using “wire-guided” method (a pipette tip was used in this study). This methodology can be easily adapted to existing commercial robotic pipetting system, while demonstrated added capabilities such as vibrational mixing, high-speed centrifuging of droplets, simple DNA extraction utilizing the hydrophobicity difference between the tip and the superhydrophobic surface, and rapid thermocycling with a moving droplet, all with wire-guided droplet manipulations on a superhydrophobic surface and a multi-chambered PCB heater (i.e., not on a 96-well plate). Serial dilutions were demonstrated for diluting sample matrix. Centrifuging was demonstrated by rotating a 10 μL droplet at 2300 round per minute, concentrating E. coli by more than 3-fold within 3 min. DNA extraction was demonstrated from E. coli sample utilizing the disposable pipette tip to cleverly attract the extracted DNA from the droplet residing on a superhydrophobic surface, which took less than 10 min. Following extraction, the 1500 bp sequence of Peptidase D from E. coli was amplified using rapid droplet thermocycling, which took 10 min for 30 cycles. The total assay time was 23 min, including droplet centrifugation, droplet DNA extraction and rapid droplet thermocycling. Evaporation from of 10 μL droplets was not significant during these procedures, since the longest time exposure to air and the vibrations was less than 5 min (during DNA extraction). The results of these sequentially executed processes were analyzed using gel electrophoresis. Thus, this work demonstrates the adaptability of the system to replace many common laboratory tasks on a single platform (through re-programmability), in rapid succession (using droplets), and with a high level of accuracy and automation. PMID:22947281

  16. Testing of a simplified LED based vis/NIR system for rapid ripeness evaluation of white grape (Vitis vinifera L.) for Franciacorta wine.

    PubMed

    Giovenzana, Valentina; Civelli, Raffaele; Beghi, Roberto; Oberti, Roberto; Guidetti, Riccardo

    2015-11-01

    The aim of this work was to test a simplified optical prototype for a rapid estimation of the ripening parameters of white grape for Franciacorta wine directly in field. Spectral acquisition based on reflectance at four wavelengths (630, 690, 750 and 850 nm) was proposed. The integration of a simple processing algorithm in the microcontroller software would allow to visualize real time values of spectral reflectance. Non-destructive analyses were carried out on 95 grape bunches for a total of 475 berries. Samplings were performed weekly during the last ripening stages. Optical measurements were carried out both using the simplified system and a portable commercial vis/NIR spectrophotometer, as reference instrument for performance comparison. Chemometric analyses were performed in order to extract the maximum useful information from optical data. Principal component analysis (PCA) was performed for a preliminary evaluation of the data. Correlations between the optical data matrix and ripening parameters (total soluble solids content, SSC; titratable acidity, TA) were carried out using partial least square (PLS) regression for spectra and using multiple linear regression (MLR) for data from the simplified device. Classification analysis were also performed with the aim of discriminate ripe and unripe samples. PCA, MLR and classification analyses show the effectiveness of the simplified system in separating samples among different sampling dates and in discriminating ripe from unripe samples. Finally, simple equations for SSC and TA prediction were calculated. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Multiplex quantification of Escherichia coli, Salmonella typhi and Vibrio cholera with three DNA targets in single reaction assay.

    PubMed

    Jangampalli Adi, Pradeepkiran; Naidu, Jagadish R; Matcha, Bhaskar

    2017-09-01

    Escherichia coli (E. coli), Salmonella typhi and Vibrio cholera harmful pathogens, which causes various diseases in humans. Rapid diagnosis of bacterial infection is an important for patient management and appropriate therapy during the early phase of the bacterial infected diseases. Among the existing techniques for identifying pathogens were less sensitive and time-consuming processes. In the present study total, 48 clinical 31 blood and 17 urine samples of patients suspected with the infections were collected from SVRR Hospital and used to detect the pathogens. Multiplex polymerase chain reaction (PCR) assay was set to design for the identification of Escherichia coli, Salmonella typhi and Vibrio cholera from the different clinical samples. Rapid diagnosis of Escherichia coli (E. coli), Salmonella and Vibrio cholera pathogens can be done with simultaneously in a single multiplex PCR assay by using specific primers with adjusted PCR conditions. Through this approach, the results represented with out of 31 blood samples 1-15 shows the positive with E. coli and remaining 14 only 11 were correlated with multiplex results of Vibrio cholera, remaining the urine samples all are positive with 17 samples correlate with the Salmonella typhi. Through the high specificity benefits of excellent sensitivity, with high resolution and reproducibility. This method of results proved and illustrates the best potential system for diagnosing the infectious disease with modern trendy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Rapid Naming and Phonological Processing as Predictors of Reading and Spelling

    ERIC Educational Resources Information Center

    Christo, Catherine; Davis, Jack

    2008-01-01

    This study examined the relationships between the cognitive processes of rapid naming and phonological processing and various literacy skills. Variables measured and used in this analysis were phonological processing, rapid naming, reading comprehension, isolated and nonsense word reading, and spelling. Data were collected from 65 second-to-fifth…

  19. A meta-model based approach for rapid formability estimation of continuous fibre reinforced components

    NASA Astrophysics Data System (ADS)

    Zimmerling, Clemens; Dörr, Dominik; Henning, Frank; Kärger, Luise

    2018-05-01

    Due to their high mechanical performance, continuous fibre reinforced plastics (CoFRP) become increasingly important for load bearing structures. In many cases, manufacturing CoFRPs comprises a forming process of textiles. To predict and optimise the forming behaviour of a component, numerical simulations are applied. However, for maximum part quality, both the geometry and the process parameters must match in mutual regard, which in turn requires numerous numerically expensive optimisation iterations. In both textile and metal forming, a lot of research has focused on determining optimum process parameters, whilst regarding the geometry as invariable. In this work, a meta-model based approach on component level is proposed, that provides a rapid estimation of the formability for variable geometries based on pre-sampled, physics-based draping data. Initially, a geometry recognition algorithm scans the geometry and extracts a set of doubly-curved regions with relevant geometry parameters. If the relevant parameter space is not part of an underlying data base, additional samples via Finite-Element draping simulations are drawn according to a suitable design-table for computer experiments. Time saving parallel runs of the physical simulations accelerate the data acquisition. Ultimately, a Gaussian Regression meta-model is built from the data base. The method is demonstrated on a box-shaped generic structure. The predicted results are in good agreement with physics-based draping simulations. Since evaluations of the established meta-model are numerically inexpensive, any further design exploration (e.g. robustness analysis or design optimisation) can be performed in short time. It is expected that the proposed method also offers great potential for future applications along virtual process chains: For each process step along the chain, a meta-model can be set-up to predict the impact of design variations on manufacturability and part performance. Thus, the method is considered to facilitate a lean and economic part and process design under consideration of manufacturing effects.

  20. Reliability of the MODS assay decentralisation process in three health regions in Peru

    PubMed Central

    Mendoza, A.; Castillo, E.; Gamarra, N.; Huamán, T.; Perea, M.; Monroi, Y.; Salazar, R.; Coronel, J.; Acurio, M.; Obregón, G.; Roper, M.; Bonilla, C.; Asencios, L.; Moore, D. A. J.

    2011-01-01

    OBJECTIVE To deliver rapid isoniazid (INH) and rifampicin (RMP) drug susceptibility testing (DST) close to the patient, we designed a decentralisation process for the microscopic observation drug susceptibility (MODS) assay in Peru and evaluated its reliability. METHODS After 2 weeks of training, laboratory staff processed ≥120 consecutive sputum samples each in three regional laboratories. Samples were processed in parallel with MODS testing at an expert laboratory. Blinded paired results were independently analysed by the Instituto Nacional de Salud (INS) according to predetermined criteria: concordance for culture, DST against INH and RMP and diagnosis of multidrug-resistant t uberculosis (MDR-TB) ≥ 95%, McNemar's P > 0.05, kappa index (κ) ≥ 0.75 and contamination 1–4%. Sensitivity and specificity for MDR-TB were calculated. RESULTS The accreditation process for Callao (126 samples, 79.4% smear-positive), Lima Sur (n = 130, 84%) and Arequipa (n = 126, 80%) took respectively 94, 97 and 173 days. Pre-determined criteria in all regional laboratories were above expected values. The sensitivity and specificity for detecting MDR-TB in regional laboratories were >95%, except for sensitivity in Lima Sur, which was 91.7%. Contamination was 1.0–2.3%. Mean delay to positive MODS results was 9.9–12.9 days. CONCLUSION Technology transfer of MODS was reliable, effective and fast, enabling the INS to accredit regional laboratories swiftly. PMID:21219684

  1. A novel method for preparing histology slides to integrate the teaching of gross and microscopic anatomy.

    PubMed

    Provo-Klimek, Judy A; Troyer, Deryl L

    2002-01-01

    The authors have previously reported the development of a novel technique for sampling and preparing tissue slides for routine microscopic examination, without the use of a microtome. Termed "RAMP" (Rapid Adhesive Mediated Procedure), this simple, albeit somewhat crude, technique holds promise as a method that can be used in the field by veterinary practitioners for rapid microscopic evaluations to obtain early preliminary estimates of the nature of a mass or lesion. We incorporated the use of this method into a gross anatomy course in an attempt to gauge its utility for novices in tissue sampling and histology slide preparation. By having each group of students take a tissue sample from their cadaver, the activity simulated an actual necropsy situation in which practitioners in the field might use the technique. Because students were able to follow their specimen from sampling to microscopic examination, the activity provided a valuable integration of their learning of gross and microscopic anatomy. We conducted an evaluation of the process and the resulting slides with two successive classes of students. We conclude that the RAMP method is reasonably successful in the hands of individuals not trained in tissue preparation; was well received by the students as a valuable learning tool; and could potentially yield useful histological information for practicing veterinarians. Limitations of the method are also discussed.

  2. A portable smart-phone device for rapid and sensitive detection of E. coli O157:H7 in Yoghurt and Egg.

    PubMed

    Zeinhom, Mohamed Maarouf Ali; Wang, Yijia; Song, Yang; Zhu, Mei-Jun; Lin, Yuehe; Du, Dan

    2018-01-15

    The detection of E. coli O157:H7 in foods has held the attention of many researchers because of the seriousness attributed to this pathogen. In this study, we present a simple, sensitive, rapid and portable smartphone based fluorescence device for E. coli O157:H7 detection. This field-portable fluorescent imager on the smartphone involves a compact laser-diode-based photosource, a long-pass (LP) thin-film interference filter and a high-quality insert lenses. The design of the device provided a low noise to background imaging system. Based on a sandwich ELISA and the specific recognition of antibody to E. coli O157:H7, the sensitive detection of E. coli O157:H7 were realized both in standard samples and real matrix in yoghurt and egg on our device. The detection limit are 1 CFU/mL and 10 CFU/mL correspondingly. Recovery percentages of spiked yogurt and egg samples with 10 3 , 10 4 and 10 5 CFU/mL E. coli O157:H7 were 106.98, 96.52 and 102.65 (in yogurt) and 107.37, 105.64 and 93.84 (in egg) samples using our device, respectively. Most importantly, the entire process could be quickly completed within two hours. This smartphone based device provides a simple, rapid, sensitive detection platform for fluorescent imaging which applied in pathogen detection for food safety monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Reliability of a rapid hematology stain for sputum cytology*

    PubMed Central

    Gonçalves, Jéssica; Pizzichini, Emilio; Pizzichini, Marcia Margaret Menezes; Steidle, Leila John Marques; Rocha, Cristiane Cinara; Ferreira, Samira Cardoso; Zimmermann, Célia Tânia

    2014-01-01

    Objective: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. Methods: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two were stained with Diff-Quik. The slides were read independently by two trained researchers blinded to the identification of the slides. The reliability for cell counting using the two techniques was evaluated by determining the intraclass correlation coefficients (ICCs) for intraobserver and interobserver agreement. Agreement in the identification of neutrophilic and eosinophilic sputum between the observers and between the stains was evaluated with kappa statistics. Results: In our comparison of the two staining techniques, the ICCs indicated almost perfect interobserver agreement for neutrophil, eosinophil, and macrophage counts (ICC: 0.98-1.00), as well as substantial agreement for lymphocyte counts (ICC: 0.76-0.83). Intraobserver agreement was almost perfect for neutrophil, eosinophil, and macrophage counts (ICC: 0.96-0.99), whereas it was moderate to substantial for lymphocyte counts (ICC = 0.65 and 0.75 for the two observers, respectively). Interobserver agreement for the identification of eosinophilic and neutrophilic sputum using the two techniques ranged from substantial to almost perfect (kappa range: 0.91-1.00). Conclusions: The use of Diff-Quik can be considered a reliable alternative for the processing of sputum samples. PMID:25029648

  4. Tracing sources of Listeria contamination in traditional Italian cheese associated with a US outbreak: investigations in Italy.

    PubMed

    Acciari, V A; Iannetti, L; Gattuso, A; Sonnessa, M; Scavia, G; Montagna, C; Addante, N; Torresi, M; Zocchi, L; Scattolini, S; Centorame, P; Marfoglia, C; Prencipe, V A; Gianfranceschi, M V

    2016-10-01

    In 2012 a US multistate outbreak of listeriosis was linked to ricotta salata imported from Italy, made from pasteurized sheep's milk. Sampling activities were conducted in Italy to trace the source of Listeria monocytogenes contamination. The cheese that caused the outbreak was produced in a plant in Apulia that processed semi-finished cheeses supplied by five plants in Sardinia. During an 'emergency sampling', 179 (23·6%) out of 758 end-products tested positive for L. monocytogenes, with concentrations from <10 c.f.u./g to 1·1 × 106 c.f.u./g. Positive processing environment samples were found in two out of four processing plants. A 'follow-up sampling' was conducted 8 months later, when environmental samples from three out of six plants tested positive for L. monocytogenes and for Listeria spp. PFGE subtyping showed 100% similarity between US clinical strains and isolates from ricotta salata, confirming the origin of the outbreak. The persistence of strains in environmental niches of processing plants was demonstrated, and is probably the cause of product contamination. Two PFGE profiles from clinical cases of listeriosis in Italy in 2011, stored in the MSS-TESSy database, were found to have 100% similarity to one PFGE profile from a US clinical case associated with the consumption of ricotta salata, according to the US epidemiological investigation (sample C, pulsotype 17). However, they had 87% similarity to the only PFGE profile found both in the US clinical case and in 14 ricotta cheese samples collected during the emergency sampling (sample B, pulsotype 1). Sharing of molecular data and availability of common characterization protocols were key elements that connected the detection of the US outbreak to the investigation of the food source in Italy. Simultaneous surveillance systems at both food and human levels are a necessity for the efficient rapid discovery of the source of an outbreak of L. monocytogenes.

  5. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    PubMed Central

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. Results The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R2 > 0.96). Conclusions The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. Am. J. Hum. Biol. 27:720–723, 2015. © 2015 The Authors American Journal of Human Biology Published by Wiley Periodicals, Inc. PMID:25754371

  6. High Throughput Strontium Isotope Method for Monitoring Fluid Flow Related to Geological CO2 Storage

    NASA Astrophysics Data System (ADS)

    Capo, R. C.; Wall, A. J.; Stewart, B. W.; Phan, T. T.; Jain, J. C.; Hakala, J. A.; Guthrie, G. D.

    2012-12-01

    Natural isotope tracers, such as strontium (Sr), can be a unique and powerful component of a monitoring strategy at a CO2 storage site, facilitating both the quantification of reaction progress for fluid-rock interactions and the tracking of brine migration caused by CO2 injection. Several challenges must be overcome, however, to enable the routine use of isotopic tracers, including the ability to rapidly analyze numerous aqueous samples with potentially complex chemical compositions. In a field situation, it might be necessary to analyze tens of samples over a short period of time to identify subsurface reactions and respond to unexpected fluid movement in the host formation. These conditions require streamlined Sr separation chemistry for samples ranging from pristine groundwaters to those containing high total dissolved solids, followed by rapid measurement of isotope ratios with high analytical precision. We have optimized Sr separation chemistry and MC-ICP-MS methods to provide rapid and precise measurements of isotope ratios in geologic, hydrologic, and environmental samples. These improvements will allow an operator to independently prepare samples for Sr isotope analysis off-site using fast, low cost chemical separation procedures and commercially available components. Existing vacuum-assisted Sr separation procedures were modified by using inexpensive disposable parts to eliminate cross contamination. Experimental results indicate that the modified columns provide excellent separation of Sr from chemically complex samples and that Sr can be effectively isolated from problematic matrix elements (e.g., Ca, Ba, K) associated with oilfield brines and formation waters. The separation procedure is designed for high sample throughput in which batches of 24 samples can be processed in approximately 2 hours, and are ready for Sr isotope measurements by MC-ICP-MS immediately after collection from the columns. Precise Sr isotope results can be achieved by MC-ICP-MS with a throughput of 4 to 5 samples per hour. Our mean measured value of NIST Sr isotope standard SRM 987 is 0.710265 ± 0.000014 (2σ, n = 94). A range of brines and CO2-rich fluids analyzed by this method yielded results within the analytical uncertainty of 87Sr/86Sr ratios previously determined by standard column separation and thermal ionization mass spectrometry. This method provides a fast and effective way to use Sr isotopes for monitoring purposes related to geological CO2 storage.

  7. SPIRAL-SPRITE: a rapid single point MRI technique for application to porous media.

    PubMed

    Szomolanyi, P; Goodyear, D; Balcom, B; Matheson, D

    2001-01-01

    This study presents the application of a new, rapid, single point MRI technique which samples k space with spiral trajectories. The general principles of the technique are outlined along with application to porous concrete samples, solid pharmaceutical tablets and gas phase imaging. Each sample was chosen to highlight specific features of the method.

  8. Dielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments

    PubMed Central

    Gascoyne, Peter R. C.; Vykoukal, Jody V.

    2009-01-01

    As the molecular origins of disease are better understood, the need for affordable, rapid, and automated technologies that enable microscale molecular diagnostics has become apparent. Widespread use of microsystems that perform sample preparation and molecular analysis could ensure that the benefits of new biomedical discoveries are realized by a maximum number of people, even those in environments lacking any infrastructure. While progress has been made in developing miniaturized diagnostic systems, samples are generally processed off-device using labor-intensive and time-consuming traditional sample preparation methods. We present the concept of an integrated programmable general-purpose sample analysis processor (GSAP) architecture where raw samples are routed to separation and analysis functional blocks contained within a single device. Several dielectrophoresis-based methods that could serve as the foundation for building GSAP functional blocks are reviewed including methods for cell and particle sorting, cell focusing, cell ac impedance analysis, cell lysis, and the manipulation of molecules and reagent droplets. PMID:19684877

  9. Dual-view plane illumination microscopy for rapid and spatially isotropic imaging

    PubMed Central

    Kumar, Abhishek; Wu, Yicong; Christensen, Ryan; Chandris, Panagiotis; Gandler, William; McCreedy, Evan; Bokinsky, Alexandra; Colón-Ramos, Daniel A; Bao, Zhirong; McAuliffe, Matthew; Rondeau, Gary; Shroff, Hari

    2015-01-01

    We describe the construction and use of a compact dual-view inverted selective plane illumination microscope (diSPIM) for time-lapse volumetric (4D) imaging of living samples at subcellular resolution. Our protocol enables a biologist with some prior microscopy experience to assemble a diSPIM from commercially available parts, to align optics and test system performance, to prepare samples, and to control hardware and data processing with our software. Unlike existing light sheet microscopy protocols, our method does not require the sample to be embedded in agarose; instead, samples are prepared conventionally on glass coverslips. Tissue culture cells and Caenorhabditis elegans embryos are used as examples in this protocol; successful implementation of the protocol results in isotropic resolution and acquisition speeds up to several volumes per s on these samples. Assembling and verifying diSPIM performance takes ~6 d, sample preparation and data acquisition take up to 5 d and postprocessing takes 3–8 h, depending on the size of the data. PMID:25299154

  10. Palladium-based Mass-Tag Cell Barcoding with a Doublet-Filtering Scheme and Single Cell Deconvolution Algorithm

    PubMed Central

    Zunder, Eli R.; Finck, Rachel; Behbehani, Gregory K.; Amir, El-ad D.; Krishnaswamy, Smita; Gonzalez, Veronica D.; Lorang, Cynthia G.; Bjornson, Zach; Spitzer, Matthew H.; Bodenmiller, Bernd; Fantl, Wendy J.; Pe’er, Dana; Nolan, Garry P.

    2015-01-01

    SUMMARY Mass-tag cell barcoding (MCB) labels individual cell samples with unique combinatorial barcodes, after which they are pooled for processing and measurement as a single multiplexed sample. The MCB method eliminates variability between samples in antibody staining and instrument sensitivity, reduces antibody consumption, and shortens instrument measurement time. Here, we present an optimized MCB protocol with several improvements over previously described methods. The use of palladium-based labeling reagents expands the number of measurement channels available for mass cytometry and reduces interference with lanthanide-based antibody measurement. An error-detecting combinatorial barcoding scheme allows cell doublets to be identified and removed from the analysis. A debarcoding algorithm that is single cell-based rather than population-based improves the accuracy and efficiency of sample deconvolution. This debarcoding algorithm has been packaged into software that allows rapid and unbiased sample deconvolution. The MCB procedure takes 3–4 h, not including sample acquisition time of ~1 h per million cells. PMID:25612231

  11. Electric Field Measurements During the Genesis and Rapid Intensification Processes (GRIP) Field Program

    NASA Technical Reports Server (NTRS)

    Bateman, Monte G.; Blakeslee, Richard J.; Mach, Douglas M.

    2010-01-01

    During the Genesis and Rapid Intensification Processes (GRIP) field program, a system of 6 electric field mills was flown on one of NASA's Global Hawk aircraft. We placed several mills on the aircraft to enable us to measure the vector electric field. We created a distributed, ethernet-connected system so that each sensor has its own embedded Linux system, complete with web server. This makes our current generation system fully "sensor web enabled." The Global Hawk has several unique qualities, but relevant to quality storm electric field measurements are high altitude (20 km) and long duration (20-30 hours) flights. There are several aircraft participating in the GRIP program, and coordinated measurements are happening. Lightning and electric field measurements will be used to study the relationships between lightning and other storm characteristics. It has been long understood that lightning can be used as a marker for strong convective activity. Past research and field programs suggest that lightning flash rate may serve as an indicator and precursor for rapid intensification change in tropical cyclones and hurricanes. We have the opportunity to sample hurricanes for many hours at a time and observe intensification (or de-intensification) periods. The electrical properties of hurricanes during such periods are not well known. American

  12. Microfluidic-Based Bacteria Isolation from Whole Blood for Diagnostics of Blood Stream Infection.

    PubMed

    Zelenin, Sergey; Ramachandraiah, Harisha; Faridi, Asim; Russom, Aman

    2017-01-01

    Bacterial blood stream infection (BSI) potentially leads to life-threatening clinical conditions and medical emergencies such as severe sepsis, septic shock, and multi organ failure syndrome. Blood culturing is currently the gold standard for the identification of microorganisms and, although it has been automated over the decade, the process still requires 24-72 h to complete. This long turnaround time, especially for the identification of antimicrobial resistance, is driving the development of rapid molecular diagnostic methods. Rapid detection of microbial pathogens in blood related to bloodstream infections will allow the clinician to decide on or adjust the antimicrobial therapy potentially reducing the morbidity, mortality, and economic burden associated with BSI. For molecular-based methods, there is a lot to gain from an improved and straightforward method for isolation of bacteria from whole blood for downstream processing.We describe a microfluidic-based sample-preparation approach that rapidly and selectively lyses all blood cells while it extracts intact bacteria for downstream analysis. Whole blood is exposed to a mild detergent, which lyses most blood cells, and then to osmotic shock using deionized water, which eliminates the remaining white blood cells. The recovered bacteria are 100 % viable, which opens up possibilities for performing drug susceptibility tests and for nucleic-acid-based molecular identification.

  13. Multicycle rapid thermal annealing optimization of Mg-implanted GaN: Evolution of surface, optical, and structural properties

    NASA Astrophysics Data System (ADS)

    Greenlee, Jordan D.; Feigelson, Boris N.; Anderson, Travis J.; Tadjer, Marko J.; Hite, Jennifer K.; Mastro, Michael A.; Eddy, Charles R.; Hobart, Karl D.; Kub, Francis J.

    2014-08-01

    The first step of a multi-cycle rapid thermal annealing process was systematically studied. The surface, structure, and optical properties of Mg implanted GaN thin films annealed at temperatures ranging from 900 to 1200 °C were investigated by Raman spectroscopy, photoluminescence, UV-visible spectroscopy, atomic force microscopy, and Nomarski microscopy. The GaN thin films are capped with two layers of in-situ metal organic chemical vapor deposition -grown AlN and annealed in 24 bar of N2 overpressure to avoid GaN decomposition. The crystal quality of the GaN improves with increasing annealing temperature as confirmed by UV-visible spectroscopy and the full widths at half maximums of the E2 and A1 (LO) Raman modes. The crystal quality of films annealed above 1100 °C exceeds the quality of the as-grown films. At 1200 °C, Mg is optically activated, which is determined by photoluminescence measurements. However, at 1200 °C, the GaN begins to decompose as evidenced by pit formation on the surface of the samples. Therefore, it was determined that the optimal temperature for the first step in a multi-cycle rapid thermal anneal process should be conducted at 1150 °C due to crystal quality and surface morphology considerations.

  14. Rapid combined assay for Salmonella detection in food samples.

    PubMed

    Gadó, I; Major, P; Király, M; Pláveczky, M G

    2000-01-01

    A rapid method was developed to detect salmonellae in food samples. The method gave a possibility to obtain results after 28 h 30 min. The preenrichment in buffered peptone water lasted for 6 h, the enrichment in Rappaport-Vassiliadis medium was applied for 18 h followed by PCR with INVA1-INVA2 primer pair, adapting Chiu and Ou's method. This procedure was suitable to demonstrate salmonella contamination at min. 10 cfu/25 g sample. Out of 18 samples there was a good agreement between the results of the conventional and rapid methods in case of 17 samples. PCR with SPVC1-SPVC2 primer pair informing about the presence of virulence plasmid was performed in separate tubes, because decreased sensitivity was observed in case of multiplex PCR.

  15. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease.

    PubMed

    Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang

    2016-06-01

    Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of <34, which accounted for 95.59% of the samples, was 100%. Discordant samples positive by RT-PCR but negative by EBOV-RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.

  16. Investigation of magnetic nanoparticles for the rapid extraction and assay of alpha-emitting radionuclides from urine: Demonstration of a novel radiobioassay method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Hara, Matthew J.; Carter, Jennifer C.; Maclellan, Jay A.

    2011-08-01

    In the event of an accidental or intentional release of radionuclides into a populated area, three things must occur in a timely manner: food and drinking water supplies must be determined to be safe to eat / drink, civilians and/or military personnel must be surveyed to ensure that they do not have external contamination, and they must be screened to ensure that significant ingestion or inhalation of radionuclides has not occurred (this paper is concerned with the latter). In the event of such a disaster, the volume of radiobioassays to be performed would be tremendous. If the event released significantmore » levels of β- or α-emitting radionuclides, in vivo assays would be ineffective. Therefore, highly efficient and rapid analytical methods for radionuclide detection from submitted spot urine samples (≤ 50 mL) would be required. At present, the quantitative determination of α-emitting radionuclides from urine samples is highly labor intensive, and requires significant sample preparation and analysis time. Sorbent materials that provide effective collection and enable rapid assay could significantly streamline the radioanalytical process. We have demonstrated the use of paramagnetic nanoparticles as a novel class of extracting media for four α-emitting radionuclides of concern (Po, Ra, Am, and U) from chemically unmodified and pH 2 human urine. Herein the initial experimental sorption results are presented along with a novel method that utilizes paramagnetic nanoparticles for the extraction of radionuclides from unmodified human urine followed by the magnetic field-induced collection of the particles for subsequent α-counting-source preparation. Additionally, we construct a versatile human dose model that determines the detector count times required to estimate internal human dose at specific protective action thresholds. The model provides a means to assess a method’s detection capabilities and use fundamental health physics parameters and actual experimental data as core variables. The modeling shows that with effective sorbent materials, rapid screening for internalized α-emitters is possible from a 50 mL spot urine sample volume collected within one week of exposure/intake.« less

  17. Laser-aided material identification for the waste sorting process

    NASA Astrophysics Data System (ADS)

    Haferkamp, Heinz; Burmester, Ingo; Engel, Kai

    1994-03-01

    The LZH has carried out investigations in the field of rapid laser-supported material- identification systems for automatic material-sorting systems. The aim of this research is the fast identification of different sorts of plastics coming from recycled rubbish or electronic waste. Within a few milliseconds a spot on the sample which has to be identified is heated with a CO2 laser. The different and specific chemical and physical material properties of the examined sample cause a different temperature distribution on the surface which is measured with an IR thermographic system. This `thermal impulse response' has to be analyzed by means of a computer system. The results of previous investigations have shown that material identification of different sorts of plastics can possibly be done at a frequency of 30 Hz. Due to economic efficiency, a high velocity identification process is necessary to sort huge waste currents.

  18. Characterizing Conformational Dynamics of Proteins Using Evolutionary Couplings.

    PubMed

    Feng, Jiangyan; Shukla, Diwakar

    2018-01-25

    Understanding of protein conformational dynamics is essential for elucidating molecular origins of protein structure-function relationship. Traditionally, reaction coordinates, i.e., some functions of protein atom positions and velocities have been used to interpret the complex dynamics of proteins obtained from experimental and computational approaches such as molecular dynamics simulations. However, it is nontrivial to identify the reaction coordinates a priori even for small proteins. Here, we evaluate the power of evolutionary couplings (ECs) to capture protein dynamics by exploring their use as reaction coordinates, which can efficiently guide the sampling of a conformational free energy landscape. We have analyzed 10 diverse proteins and shown that a few ECs are sufficient to characterize complex conformational dynamics of proteins involved in folding and conformational change processes. With the rapid strides in sequencing technology, we expect that ECs could help identify reaction coordinates a priori and enhance the sampling of the slow dynamical process associated with protein folding and conformational change.

  19. Genome chaos: survival strategy during crisis.

    PubMed

    Liu, Guo; Stevens, Joshua B; Horne, Steven D; Abdallah, Batoul Y; Ye, Karen J; Bremer, Steven W; Ye, Christine J; Chen, David J; Heng, Henry H

    2014-01-01

    Genome chaos, a process of complex, rapid genome re-organization, results in the formation of chaotic genomes, which is followed by the potential to establish stable genomes. It was initially detected through cytogenetic analyses, and recently confirmed by whole-genome sequencing efforts which identified multiple subtypes including "chromothripsis", "chromoplexy", "chromoanasynthesis", and "chromoanagenesis". Although genome chaos occurs commonly in tumors, both the mechanism and detailed aspects of the process are unknown due to the inability of observing its evolution over time in clinical samples. Here, an experimental system to monitor the evolutionary process of genome chaos was developed to elucidate its mechanisms. Genome chaos occurs following exposure to chemotherapeutics with different mechanisms, which act collectively as stressors. Characterization of the karyotype and its dynamic changes prior to, during, and after induction of genome chaos demonstrates that chromosome fragmentation (C-Frag) occurs just prior to chaotic genome formation. Chaotic genomes seem to form by random rejoining of chromosomal fragments, in part through non-homologous end joining (NHEJ). Stress induced genome chaos results in increased karyotypic heterogeneity. Such increased evolutionary potential is demonstrated by the identification of increased transcriptome dynamics associated with high levels of karyotypic variance. In contrast to impacting on a limited number of cancer genes, re-organized genomes lead to new system dynamics essential for cancer evolution. Genome chaos acts as a mechanism of rapid, adaptive, genome-based evolution that plays an essential role in promoting rapid macroevolution of new genome-defined systems during crisis, which may explain some unwanted consequences of cancer treatment.

  20. Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid and Sensitive Identification of Ostrich Meat

    PubMed Central

    Abdulmawjood, Amir; Grabowski, Nils; Fohler, Svenja; Kittler, Sophie; Nagengast, Helga; Klein, Guenter

    2014-01-01

    Animal species identification is one of the primary duties of official food control. Since ostrich meat is difficult to be differentiated macroscopically from beef, therefore new analytical methods are needed. To enforce labeling regulations for the authentication of ostrich meat, it might be of importance to develop and evaluate a rapid and reliable assay. In the present study, a loop-mediated isothermal amplification (LAMP) assay based on the cytochrome b gene of the mitochondrial DNA of the species Struthio camelus was developed. The LAMP assay was used in combination with a real-time fluorometer. The developed system allowed the detection of 0.01% ostrich meat products. In parallel, a direct swab method without nucleic acid extraction using the HYPLEX LPTV buffer was also evaluated. This rapid processing method allowed detection of ostrich meat without major incubation steps. In summary, the LAMP assay had excellent sensitivity and specificity for detecting ostrich meat and could provide a sampling-to-result identification-time of 15 to 20 minutes. PMID:24963709

  1. Rapid, Sensitive Detection of Botulinum Toxin on a Flexible Microfluidics Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warner, Marvin G.; Dockendorff, Brian P.; Feldhaus, Michael J.

    2004-10-30

    In this paper we will describe how high affinity reagents and a sensor configuration enabling rapid mass transport can be combined for rapid, sensitive biodetection. The system that we have developed includes a renewable surface immunoassay, which involves on-column detection of a fluorescently labeled secondary antibody in a sandwich immunoassay. Yeast display and directed molecular evolution were used to create high affinity antibodies to the botulinum toxin heavy chain receptor binding domain, AR1 and 3D12. A rotating rod renewable surface microcolumn was used to form a microliter-sized column containing beads functionalized with the capture antibody (AR1). The column was perfusedmore » with sample, wash solutions, and a fluorescently labeled secondary antibody (3D12) while the on-column fluorescence was monitored. Detection was accomplished in less than 5 minutes, with a total processing time of about 10 minutes. On-column detection of botulinum toxin was more sensitive and much faster than flow cytometry analysis on microbeads using the same reagents.« less

  2. Interdigitated microelectrode based impedance biosensor for detection of salmonella enteritidis in food samples

    NASA Astrophysics Data System (ADS)

    Kim, G.; Morgan, M.; Hahm, B. K.; Bhunia, A.; Mun, J. H.; Om, A. S.

    2008-03-01

    Salmonella enteritidis outbreaks continue to occur, and S. enteritidis-related outbreaks from various food sources have increased public awareness of this pathogen. Conventional methods for pathogens detection and identification are labor-intensive and take days to complete. Some immunological rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown great potential for the rapid detection of foodborne pathogens. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on avidin-biotin binding on the surface of the IME to form an active sensing layer. To increase the sensitivity of the sensor, three types of sensors that have different electrode gap sizes (2 μm, 5 μm, 10 μm) were fabricated and tested. The impedimetric biosensor could detect 103 CFU/mL of Salmonella in pork meat extract with an incubation time of 5 minutes. This method may provide a simple, rapid and sensitive method to detect foodborne pathogens.

  3. Rapid Detection of Pathogenic Bacteria from Fresh Produce by Filtration and Surface-Enhanced Raman Spectroscopy

    NASA Astrophysics Data System (ADS)

    Wu, Xiaomeng; Han, Caiqin; Chen, Jing; Huang, Yao-Wen; Zhao, Yiping

    2016-04-01

    The detection of Salmonella Poona from cantaloupe cubes and E. coli O157:H7 from lettuce has been explored by using a filtration method and surface-enhanced Raman spectroscopy (SERS) based on vancomycin-functionalized silver nanorod array substrates. It is found that with a two-step filtration process, the limit of detection (LOD) of Salmonella Poona from cantaloupe cubes can be as low as 100 CFU/mL in less than 4 h, whereas the chlorophyll in the lettuce causes severe SERS spectral interference. To improve the LOD of lettuce, a three-step filtration method with a hydrophobic filter is proposed. The hydrophobic filter can effectively eliminate the interferences from chlorophyll and achieve a LOD of 1000 CFU/mL detection of E. coli O157:H7 from lettuce samples within 5 h. With the low LODs and rapid detection time, the SERS biosensing platform has demonstrated its potential as a rapid, simple, and inexpensive means for pathogenic bacteria detection from fresh produce.

  4. The 9-MilCA method as a rapid, partly automated protocol for simultaneously recording milk coagulation, curd firming, syneresis, cheese yield, and curd nutrients recovery or whey loss.

    PubMed

    Cipolat-Gotet, C; Cecchinato, A; Stocco, G; Bittante, G

    2016-02-01

    The aim of this study was to propose and test a new laboratory cheesemaking procedure [9-mL milk cheesemaking assessment (9-MilCA)], which records 15 traits related to milk coagulation, curd firming, syneresis, cheese yield, and curd nutrients recovery or whey loss. This procedure involves instruments found in many laboratories (i.e., heaters and lacto-dynamographs), with an easy modification of the sample rack for the insertion of 10-mL glass tubes. Four trials were carried out to test the 9-MilCA procedure. The first trial compared 8 coagulation and curd firming traits obtained using regular or modified sample racks to process milk samples from 60 cows belonging to 5 breeds and 3 farms (480 tests). The obtained patterns exhibited significant but irrelevant between-procedure differences, with better repeatability seen for 9-MilCA. The second trial tested the reproducibility and repeatability of the 7 cheesemaking traits obtained using the 9-MilCA procedure on individual samples from 60 cows tested in duplicate in 2 instruments (232 tests). The method yielded very repeatable outcomes for all 7 tested cheese yield and nutrient recovery traits (repeatability >98%), with the exception of the fresh cheese yield (84%), which was affected by the lower repeatability (67%) of the water retained in the curd. In the third trial (96 tests), we found that using centrifugation in place of curd cooking and draining (as adopted in several published studies) reduced the efficiency of whey separation, overestimated all traits, and worsened the repeatability. The fourth trial compared 9-MilCA with a more complex model cheese-manufacturing process that mimics industry practices, using 1,500-mL milk samples (72 cows, 216 tests). The average results obtained from 9-MilCA were similar to those obtained from the model cheeses, with between-method correlations ranging from 78 to 99%, except for the water retained in the curd (r=54%). Our results indicate that new 9-MilCA method is a powerful research tool that allows the rapid, inexpensive, and partly automated analysis processing 40 samples per day with 2 replicates each, using 1 lacto-dynamograph, 2 heaters, and 3 modified sample racks, and yields a complete picture of the cheesemaking process (e.g., milk gelation, curd firming, syneresis, and whey expulsion) as well as the cheese yield and the efficiency of energy or nutrients retention in the cheese or loss in the whey. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Isolation of Clostridium spiroforme from rabbits.

    PubMed

    Holmes, H T; Sonn, R J; Patton, N M

    1988-04-01

    The isolation of Clostridium spiroforme from intestinal contents of rabbits was achieved by sampling the supernatant-pellet interphase of centrifuged specimens processed for routine toxin analysis. High-speed centrifugation at 20,000x for 15 minutes provided a rapid and effective means of separating this anaerobic pathogen from the majority of both indigenous and non-indigenous intestinal microbial flora. The unusual helically-coiled, semicircular shape of the microorganism is considered, at least in part, responsible for this phenomenon.

  6. Ultrasound-assisted magnetic dispersive solid-phase microextraction: A novel approach for the rapid and efficient microextraction of naproxen and ibuprofen employing experimental design with high-performance liquid chromatography.

    PubMed

    Ghorbani, Mahdi; Chamsaz, Mahmoud; Rounaghi, Gholam Hossein

    2016-03-01

    A simple, rapid, and sensitive method for the determination of naproxen and ibuprofen in complex biological and water matrices (cow milk, human urine, river, and well water samples) has been developed using ultrasound-assisted magnetic dispersive solid-phase microextraction. Magnetic ethylendiamine-functionalized graphene oxide nanocomposite was synthesized and used as a novel adsorbent for the microextraction process and showed great adsorptive ability toward these analytes. Different parameters affecting the microextraction were optimized with the aid of the experimental design approach. A Plackett-Burman screening design was used to study the main variables affecting the microextraction process, and the Box-Behnken optimization design was used to optimize the previously selected variables for extraction of naproxen and ibuprofen. The optimized technique provides good repeatability (relative standard deviations of the intraday precision 3.1 and 3.3, interday precision of 5.6 and 6.1%), linearity (0.1-500 and 0.3-650 ng/mL), low limits of detection (0.03 and 0.1 ng/mL), and a high enrichment factor (168 and 146) for naproxen and ibuprofen, respectively. The proposed method can be successfully applied in routine analysis for determination of naproxen and ibuprofen in cow milk, human urine, and real water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Validation of a One-Step Method for Extracting Fatty Acids from Salmon, Chicken and Beef Samples.

    PubMed

    Zhang, Zhichao; Richardson, Christine E; Hennebelle, Marie; Taha, Ameer Y

    2017-10-01

    Fatty acid extraction methods are time-consuming and expensive because they involve multiple steps and copious amounts of extraction solvents. In an effort to streamline the fatty acid extraction process, this study compared the standard Folch lipid extraction method to a one-step method involving a column that selectively elutes the lipid phase. The methods were tested on raw beef, salmon, and chicken. Compared to the standard Folch method, the one-step extraction process generally yielded statistically insignificant differences in chicken and salmon fatty acid concentrations, percent composition and weight percent. Initial testing showed that beef stearic, oleic and total fatty acid concentrations were significantly lower by 9-11% with the one-step method as compared to the Folch method, but retesting on a different batch of samples showed a significant 4-8% increase in several omega-3 and omega-6 fatty acid concentrations with the one-step method relative to the Folch. Overall, the findings reflect the utility of a one-step extraction method for routine and rapid monitoring of fatty acids in chicken and salmon. Inconsistencies in beef concentrations, although minor (within 11%), may be due to matrix effects. A one-step fatty acid extraction method has broad applications for rapidly and routinely monitoring fatty acids in the food supply and formulating controlled dietary interventions. © 2017 Institute of Food Technologists®.

  8. Review on CNC-Rapid Prototyping

    NASA Astrophysics Data System (ADS)

    Z, M. Nafis O.; Y, Nafrizuan M.; A, Munira M.; J, Kartina

    2012-09-01

    This article reviewed developments of Computerized Numerical Control (CNC) technology in rapid prototyping process. Rapid prototyping (RP) can be classified into three major groups; subtractive, additive and virtual. CNC rapid prototyping is grouped under the subtractive category which involves material removal from the workpiece that is larger than the final part. Richard Wysk established the use of CNC machines for rapid prototyping using sets of 2½-D tool paths from various orientations about a rotary axis to machine parts without refixturing. Since then, there are few developments on this process mainly aimed to optimized the operation and increase the process capabilities to stand equal with common additive type of RP. These developments include the integration between machining and deposition process (hybrid RP), adoption of RP to the conventional machine and optimization of the CNC rapid prototyping process based on controlled parameters. The article ended by concluding that the CNC rapid prototyping research area has a vast space for improvement as in the conventional machining processes. Further developments and findings will enhance the usage of this method and minimize the limitation of current approach in building a prototype.

  9. Survival and Risk Comparison of Campylobacter jejuni on Various Processed Meat Products

    PubMed Central

    Hong, Soo Hyeon; Kim, Han Sol; Yoon, Ki Sun

    2016-01-01

    The objective of this study was to investigate survival kinetics of Campylobacter jejuni on various processed meat products (dry-cured ham, round ham with/without sodium nitrite, garlic seasoned ham with/without sodium nitrite, and sausage without sodium nitrite). Additionally, a semi-quantitative risk assessment of C. jejuni on various processed meat products was conducted using FDA-iRISK 1.0. Inoculated processed meat products with 6.0 ± 0.5 log CFU/g of C. jejuni were vacuum packed and stored at 4, 10, 17, 24, 30, and 36 °C. Survival curves were fitted to the Weibull model to obtain the delta values of C. jejuni on various processed meat products. The most rapid death of C. jejuni was observed on dry-cured ham, followed by sausage without sodium nitrite. The results of semi-quantitative risk assessment indicate that dry-cured ham represented the lowest risk among all samples. C. jejuni on processed meats presented a greater risk at 4 °C than at 10 °C. The risk of ham was greater than the risk of sausage, regardless of type. Among all samples, the highest risk of C. jejuni was observed in round ham without sodium nitrite. Overall, our data indicates that risk of processed meat products due to C. jejuni is relatively low. PMID:27294947

  10. Optimization of ultrahigh-speed multiplex PCR for forensic analysis.

    PubMed

    Gibson-Daw, Georgiana; Crenshaw, Karin; McCord, Bruce

    2018-01-01

    In this paper, we demonstrate the design and optimization of an ultrafast PCR amplification technique, used with a seven-locus multiplex that is compatible with conventional capillary electrophoresis systems as well as newer microfluidic chip devices. The procedure involves the use of a high-speed polymerase and a rapid cycling protocol to permit multiplex PCR amplification of forensic short tandem repeat loci in 6.5 min. We describe the selection and optimization of master mix reagents such as enzyme, buffer, MgCl 2 , and dNTPs, as well as primer ratios, total volume, and cycle conditions, in order to get the best profile in the shortest time possible. Sensitivity and reproducibility studies are also described. The amplification process utilizes a small high-speed thermocycler and compact laptop, making it portable and potentially useful for rapid, inexpensive on-site genotyping. The seven loci of the multiplex were taken from conventional STR genotyping kits and selected for their size and lack of overlap. Analysis was performed using conventional capillary electrophoresis and microfluidics with fluorescent detection. Overall, this technique provides a more rapid method for rapid sample screening of suspects and victims. Graphical abstract Rapid amplification of forensic DNA using high speed thermal cycling followed by capillary or microfluidic electrophoresis.

  11. A method for the rapid detection of urinary tract infections.

    PubMed

    Olsson, Carl; Kapoor, Deepak; Howard, Glenn

    2012-04-01

    To determine the reliability of a rapid detection method compared with the reference standard streaked agar plate in diagnosing the presence of urinary tract infection (UTI). De-identified clean catch urine specimens from 980 office visit patients were processed during a 30-day period. Classic 1-μL and 10-μL streaked agar plates were used in parallel with the new CultureStat Rapid UTI Detection System (CSRUDS). Urine results were evaluated using the CSRUDS at 30 and 90 minutes after collection. A comparative analysis of the subsequent plate results versus the CSRUDS results was achieved for 973 of these samples. Positive UTI conditions were accurately identified by both CSRUDS and agar streak plate methods. CSRUDS accurately identified UTI negative conditions with 99.3% reliability at 90 minutes. The negative predictive value of CSRUDS was 99.2% at 30 minutes. Current agar plating for first-round UTI screening has substantial documented problems that can negatively affect an accurate and timely UTI diagnosis. A novel rapid detection system, the CSRUDS provides UTI negative/positive same-day results in ≤ 90 minutes from the start of test. Such rapidly available results will enable more accurate and timely clinical decisions to be made in the urology office, particularly regarding infection status before urologic instrumentation. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. BIOHAZ: Rapid On-Site Biological Detection for First Responders

    DTIC Science & Technology

    2001-09-01

    numbers comprise the compilation report: ADP013371 thru ADP013468 UNCLASSIFIED 84. BIORAZ: Rapid On- Site Biological Detection for First Responders Randall... responders an integated capability to collect an environmental sample and to rapidly screen that sample on site for the presence of biological material. This...further analyzed on site with immunoassay tickets before being sent to a laboratory. This system provides the emergency responders with a capability that

  13. Development of Rapid Isothermal Amplification Assays for Detection of Phytophthora spp. in Plant Tissue.

    PubMed

    Miles, Timothy D; Martin, Frank N; Coffey, Michael D

    2015-02-01

    Several isothermal amplification techniques recently have been developed that are tolerant of inhibitors present in many plant extracts, which can reduce the need for obtaining purified DNA for running diagnostic assays. One such commercially available technique that has similarities with real-time polymerase chain reaction (PCR) for designing primers and a labeled probe is recombinase polymerase amplification (RPA). This technology was used to develop two simple and rapid approaches for detection of Phytophthora spp.: one genus-specific assay multiplexed with a plant internal control and the other species-specific assays for Phytophthora ramorum and P. kernoviae. All assays were tested for sensitivity (ranging from 3 ng to 1 fg of DNA) and specificity using DNA extracted from more than 136 Phytophthora taxa, 21 Pythium spp., 1 Phytopythium sp., and a wide range of plant species. The lower limit of linear detection using purified DNA was 200 to 300 fg of DNA in all pathogen RPA assays. Six different extraction buffers were tested for use during plant tissue maceration and the assays were validated in the field by collecting 222 symptomatic plant samples from over 50 different hosts. Only 56 samples were culture positive for Phytophthora spp. whereas 91 were positive using the Phytophthora genus-specific RPA test and a TaqMan real-time PCR assay. A technique for the generation of sequencing templates from positive RPA amplifications to confirm species identification was also developed. These RPA assays have added benefits over traditional technologies because they are rapid (results can be obtained in as little as 15 min), do not require DNA extraction or extensive training to complete, use less expensive portable equipment than PCR-based assays, and are significantly more specific than current immunologically based methods. This should provide a rapid, field-deployable capability for pathogen detection that will facilitate point-of-sample collection processing, thereby reducing the time necessary for accurate diagnostics and making management decisions.

  14. Thermal analysis of the vortex tube based thermocycler for fast DNA amplification: Experimental and two-dimensional numerical results

    NASA Astrophysics Data System (ADS)

    Raghavan, V.; Whitney, Scott E.; Ebmeier, Ryan J.; Padhye, Nisha V.; Nelson, Michael; Viljoen, Hendrik J.; Gogos, George

    2006-09-01

    In this article, experimental and numerical analyses to investigate the thermal control of an innovative vortex tube based polymerase chain reaction (VT-PCR) thermocycler are described. VT-PCR is capable of rapid DNA amplification and real-time optical detection. The device rapidly cycles six 20μl 96bp λ-DNA samples between the PCR stages (denaturation, annealing, and elongation) for 30cycles in approximately 6min. Two-dimensional numerical simulations have been carried out using computational fluid dynamics (CFD) software FLUENT v.6.2.16. Experiments and CFD simulations have been carried out to measure/predict the temperature variation between the samples and within each sample. Heat transfer rate (primarily dictated by the temperature differences between the samples and the external air heating or cooling them) governs the temperature distribution between and within the samples. Temperature variation between and within the samples during the denaturation stage has been quite uniform (maximum variation around ±0.5 and 1.6°C, respectively). During cooling, by adjusting the cold release valves in the VT-PCR during some stage of cooling, the heat transfer rate has been controlled. Improved thermal control, which increases the efficiency of the PCR process, has been obtained both experimentally and numerically by slightly decreasing the rate of cooling. Thus, almost uniform temperature distribution between and within the samples (within 1°C) has been attained for the annealing stage as well. It is shown that the VT-PCR is a fully functional PCR machine capable of amplifying specific DNA target sequences in less time than conventional PCR devices.

  15. An overview of the main foodstuff sample preparation technologies for tetracycline residue determination.

    PubMed

    Pérez-Rodríguez, Michael; Pellerano, Roberto Gerardo; Pezza, Leonardo; Pezza, Helena Redigolo

    2018-05-15

    Tetracyclines are widely used for both the treatment and prevention of diseases in animals as well as for the promotion of rapid animal growth and weight gain. This practice may result in trace amounts of these drugs in products of animal origin, such as milk and eggs, posing serious risks to human health. The presence of tetracycline residues in foods can lead to the transmission of antibiotic-resistant pathogenic bacteria through the food chain. In order to ensure food safety and avoid exposure to these substances, national and international regulatory agencies have established tolerance levels for authorized veterinary drugs, including tetracycline antimicrobials. In view of that, numerous sensitive and specific methods have been developed for the quantification of these compounds in different food matrices. One will note, however, that the determination of trace residues in foods such as milk and eggs often requires extensive sample extraction and preparation prior to conducting instrumental analysis. Sample pretreatment is usually the most complicated step in the analytical process and covers both cleaning and pre-concentration. Optimal sample preparation can reduce analysis time and sources of error, enhance sensitivity, apart from enabling unequivocal identification, confirmation and quantification of target analytes. The development and implementation of more environmentally friendly analytical procedures, which involve the use of less hazardous solvents and smaller sample sizes compared to traditional methods, is a rapidly increasing trend in analytical chemistry. This review seeks to provide an updated overview of the main trends in sample preparation for the determination of tetracycline residues in foodstuffs. The applicability of several extraction and clean-up techniques employed in the analysis of foodstuffs, especially milk and egg samples, is also thoroughly discussed. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device

    PubMed Central

    Boardman, Anna K.; Campbell, Jennifer; Wirz, Holger; Sharon, Andre; Sauer-Budge, Alexis F.

    2015-01-01

    Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1–100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detection. Current culture-based methods can take a minimum of two days, while faster methods like PCR require a sample free of inhibitors (i.e., blood components). Though commercial kits exist for the removal of blood from these samples, they typically capture only DNA, thereby necessitating the use of blood culture for antimicrobial testing. Here, we report a novel, scaled-up sample preparation protocol carried out in a new microbial concentration device. The process can efficiently lyse 10 mL of bacteremic blood while maintaining the microorganisms’ viability, giving a 30‑μL final output volume. A suite of six microorganisms (Staphylococcus aureus, Streptococcus pneumoniae, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, and Candida albicans) at a range of clinically relevant concentrations was tested. All of the microorganisms had recoveries greater than 55% at the highest tested concentration of 100 CFU/mL, with three of them having over 70% recovery. At the lowest tested concentration of 3 CFU/mL, two microorganisms had recoveries of ca. 40–50% while the other four gave recoveries greater than 70%. Using a Taqman assay for methicillin-sensitive S. aureus (MSSA)to prove the feasibility of downstream analysis, we show that our microbial pellets are clean enough for PCR amplification. PCR testing of 56 spiked-positive and negative samples gave a specificity of 0.97 and a sensitivity of 0.96, showing that our sample preparation protocol holds great promise for the rapid diagnosis of bacteremia directly from a primary sample. PMID:25675242

  17. Radioactive sample effects on EDXRF spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worley, Christopher G

    2008-01-01

    Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (amore » heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.« less

  18. Single molecule targeted sequencing for cancer gene mutation detection.

    PubMed

    Gao, Yan; Deng, Liwei; Yan, Qin; Gao, Yongqian; Wu, Zengding; Cai, Jinsen; Ji, Daorui; Li, Gailing; Wu, Ping; Jin, Huan; Zhao, Luyang; Liu, Song; Ge, Liangjin; Deem, Michael W; He, Jiankui

    2016-05-19

    With the rapid decline in cost of sequencing, it is now affordable to examine multiple genes in a single disease-targeted clinical test using next generation sequencing. Current targeted sequencing methods require a separate step of targeted capture enrichment during sample preparation before sequencing. Although there are fast sample preparation methods available in market, the library preparation process is still relatively complicated for physicians to use routinely. Here, we introduced an amplification-free Single Molecule Targeted Sequencing (SMTS) technology, which combined targeted capture and sequencing in one step. We demonstrated that this technology can detect low-frequency mutations using artificially synthesized DNA sample. SMTS has several potential advantages, including simple sample preparation thus no biases and errors are introduced by PCR reaction. SMTS has the potential to be an easy and quick sequencing technology for clinical diagnosis such as cancer gene mutation detection, infectious disease detection, inherited condition screening and noninvasive prenatal diagnosis.

  19. Rapid imaging, detection and quantification of Giardia lamblia cysts using mobile-phone based fluorescent microscopy and machine learning.

    PubMed

    Koydemir, Hatice Ceylan; Gorocs, Zoltan; Tseng, Derek; Cortazar, Bingen; Feng, Steve; Chan, Raymond Yan Lok; Burbano, Jordi; McLeod, Euan; Ozcan, Aydogan

    2015-03-07

    Rapid and sensitive detection of waterborne pathogens in drinkable and recreational water sources is crucial for treating and preventing the spread of water related diseases, especially in resource-limited settings. Here we present a field-portable and cost-effective platform for detection and quantification of Giardia lamblia cysts, one of the most common waterborne parasites, which has a thick cell wall that makes it resistant to most water disinfection techniques including chlorination. The platform consists of a smartphone coupled with an opto-mechanical attachment weighing ~205 g, which utilizes a hand-held fluorescence microscope design aligned with the camera unit of the smartphone to image custom-designed disposable water sample cassettes. Each sample cassette is composed of absorbent pads and mechanical filter membranes; a membrane with 8 μm pore size is used as a porous spacing layer to prevent the backflow of particles to the upper membrane, while the top membrane with 5 μm pore size is used to capture the individual Giardia cysts that are fluorescently labeled. A fluorescence image of the filter surface (field-of-view: ~0.8 cm(2)) is captured and wirelessly transmitted via the mobile-phone to our servers for rapid processing using a machine learning algorithm that is trained on statistical features of Giardia cysts to automatically detect and count the cysts captured on the membrane. The results are then transmitted back to the mobile-phone in less than 2 minutes and are displayed through a smart application running on the phone. This mobile platform, along with our custom-developed sample preparation protocol, enables analysis of large volumes of water (e.g., 10-20 mL) for automated detection and enumeration of Giardia cysts in ~1 hour, including all the steps of sample preparation and analysis. We evaluated the performance of this approach using flow-cytometer-enumerated Giardia-contaminated water samples, demonstrating an average cyst capture efficiency of ~79% on our filter membrane along with a machine learning based cyst counting sensitivity of ~84%, yielding a limit-of-detection of ~12 cysts per 10 mL. Providing rapid detection and quantification of microorganisms, this field-portable imaging and sensing platform running on a mobile-phone could be useful for water quality monitoring in field and resource-limited settings.

  20. Rapid sintering of anisotropic, nanograined Nd-Fe-B by flash-spark plasma sintering

    NASA Astrophysics Data System (ADS)

    Castle, Elinor; Sheridan, Richard; Grasso, Salvatore; Walton, Allan; Reece, Mike

    2016-11-01

    A Spark Plasma Sintering (SPS) furnace was used to Flash-Sinter (FS) Nd-Fe-Dy-Co-B-Ga melt spun permanent magnetic material. During the 10 s "Flash" process (heating rate 2660 K min-1), sample sintering (to theoretical density) and deformation (54% height reduction) occurred. This produced texturing and significant magnetic anisotropy, comparable to conventional die-upset magnets; yet with much greater coercivities (>1600 kA m-1) due to the nanoscale characteristics of the plate-like sintered grains. These preliminary results suggest that Flash-SPS could provide a new processing route for the mass production of highly anisotropic, nanocrystalline magnetic materials with high coercivity.

  1. Comparison of immunomagnetic separation/adenosine triphosphate rapid method to traditional culture-based method for E. coli and enterococci enumeration in wastewater

    USGS Publications Warehouse

    Bushon, R.N.; Likirdopulos, C.A.; Brady, A.M.G.

    2009-01-01

    Untreated wastewater samples from California, North Carolina, and Ohio were analyzed by the immunomagnetic separation/adenosine triphosphate (IMS/ATP) method and the traditional culture-based method for E. coli and enterococci concentrations. The IMS/ATP method concentrates target bacteria by immunomagnetic separation and then quantifies captured bacteria by measuring bioluminescence induced by release of ATP from the bacterial cells. Results from this method are available within 1 h from the start of sample processing. Significant linear correlations were found between the IMS/ATP results and results from traditional culture-based methods for E. coli and enterococci enumeration for one location in California, two locations in North Carolina, and one location in Ohio (r??values ranged from 0.87 to 0.97). No significant linear relation was found for a second location in California that treats a complex mixture of residential and industrial wastewater. With the exception of one location, IMS/ATP showed promise as a rapid method for the quantification of faecal-indicator organisms in wastewater.

  2. Recombinase Polymerase Amplification (RPA) of CaMV-35S Promoter and nos Terminator for Rapid Detection of Genetically Modified Crops

    PubMed Central

    Xu, Chao; Li, Liang; Jin, Wujun; Wan, Yusong

    2014-01-01

    Recombinase polymerase amplification (RPA) is a novel isothermal DNA amplification and detection technology that enables the amplification of DNA within 30 min at a constant temperature of 37–42 °C by simulating in vivo DNA recombination. In this study, based on the regulatory sequence of the cauliflower mosaic virus 35S (CaMV-35S) promoter and the Agrobacterium tumefaciens nopaline synthase gene (nos) terminator, which are widely incorporated in genetically modified (GM) crops, we designed two sets of RPA primers and established a real-time RPA detection method for GM crop screening and detection. This method could reliably detect as few as 100 copies of the target molecule in a sample within 15–25 min. Furthermore, the real-time RPA detection method was successfully used to amplify and detect DNA from samples of four major GM crops (maize, rice, cotton, and soybean). With this novel amplification method, the test time was significantly shortened and the reaction process was simplified; thus, this method represents an effective approach to the rapid detection of GM crops. PMID:25310647

  3. Microwave energy fixation for electron microscopy.

    PubMed Central

    Login, G. R.; Dvorak, A. M.

    1985-01-01

    We have demonstrated that microwave energy (MW) can be used in conjunction with chemical cross-linking agents in order to rapidly fix cell suspensions and tissue blocks for electron microscopy in 7-9 seconds. The optimal MW fixation method involved immersing tissues up to 1 cu cm in dilute aldehyde fixation and immediately irradiating the specimens in a conventional microwave oven for 9 seconds to 50 C. Ultrastructural preservation of samples irradiated by MW energy was comparable to that of the control samples immersed in aldehyde fixative for 2 hours at 25 C. Stereologic analysis showed that tissue blocks fixed by the MW fixation method did not cause organelles such as liver mitochondria and salivary gland granules to shrink or to swell. Potential applications for this new fixation technology include the investigation of rapid intracellular processes (eg, vesicular transport) and preservation of proteins that are difficult to demonstrate with routine fixation methods (eg, antigens and enzymes). Images Figure 4 Figure 5 Figure 2 Figure 3 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 PMID:3927740

  4. Rapid and sensitive ultrasonic-assisted derivatisation microextraction (UDME) technique for bitter taste-free amino acids (FAA) study by HPLC-FLD.

    PubMed

    Chen, Guang; Li, Jun; Sun, Zhiwei; Zhang, Shijuan; Li, Guoliang; Song, Cuihua; Suo, Yourui; You, Jinmao

    2014-01-15

    Amino acids, as the main contributors to taste, are usually found in relatively high levels in bitter foods. In this work, we focused on seeking a rapid, sensitive and simple method to determine FAA for large batches of micro-samples and to explore the relationship between FAA and bitterness. Overall condition optimisation indicated that the new UDME technique offered higher derivatisation yields and extraction efficiencies than traditional methods. Only 35min was needed in the whole operation process. Very low LLOQ (Lower limit of quantification: 0.21-5.43nmol/L) for FAA in twelve bitter foods was obtained, with which BTT (bitter taste thresholds) and CABT (content of FAA at BTT level) were newly determined. The ratio of CABT to BTT increased with decreasing of BTT. This work provided powerful potential for the high-throughput trace analysis of micro-sample and also a methodology to study the relationship between the chemical constituents and the taste. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Recombinase polymerase amplification (RPA) of CaMV-35S promoter and nos terminator for rapid detection of genetically modified crops.

    PubMed

    Xu, Chao; Li, Liang; Jin, Wujun; Wan, Yusong

    2014-10-10

    Recombinase polymerase amplification (RPA) is a novel isothermal DNA amplification and detection technology that enables the amplification of DNA within 30 min at a constant temperature of 37-42 °C by simulating in vivo DNA recombination. In this study, based on the regulatory sequence of the cauliflower mosaic virus 35S (CaMV-35S) promoter and the Agrobacterium tumefaciens nopaline synthase gene (nos) terminator, which are widely incorporated in genetically modified (GM) crops, we designed two sets of RPA primers and established a real-time RPA detection method for GM crop screening and detection. This method could reliably detect as few as 100 copies of the target molecule in a sample within 15-25 min. Furthermore, the real-time RPA detection method was successfully used to amplify and detect DNA from samples of four major GM crops (maize, rice, cotton, and soybean). With this novel amplification method, the test time was significantly shortened and the reaction process was simplified; thus, this method represents an effective approach to the rapid detection of GM crops.

  6. Detailed Visualization of Phase Evolution during Rapid Formation of Cu(InGa)Se2 Photovoltaic Absorber from Mo/CuGa/In/Se Precursors.

    PubMed

    Koo, Jaseok; Kim, Sammi; Cheon, Taehoon; Kim, Soo-Hyun; Kim, Woo Kyoung

    2018-03-02

    Amongst several processes which have been developed for the production of reliable chalcopyrite Cu(InGa)Se 2 photovoltaic absorbers, the 2-step metallization-selenization process is widely accepted as being suitable for industrial-scale application. Here we visualize the detailed thermal behavior and reaction pathways of constituent elements during commercially attractive rapid thermal processing of glass/Mo/CuGa/In/Se precursors on the basis of the results of systematic characterization of samples obtained from a series of quenching experiments with set-temperatures between 25 and 550 °C. It was confirmed that the Se layer crystallized and then melted between 250 and 350 °C, completely disappearing at 500 °C. The formation of CuInSe 2 and Cu(InGa)Se 2 was initiated at around 450 °C and 550 °C, respectively. It is suggested that pre-heat treatment to control crystallization of Se layer should be designed at 250-350 °C and Cu(InGa)Se 2 formation from CuGa/In/Se precursors can be completed within a timeframe of 6 min.

  7. Microwave-assisted rapid photocatalytic degradation of malachite green in TiO2 suspensions: mechanism and pathways.

    PubMed

    Ju, Yongming; Yang, Shaogui; Ding, Youchao; Sun, Cheng; Zhang, Aiqian; Wang, Lianhong

    2008-11-06

    Microwave-assisted photocatalytic (MPC) degradation of malachite green (MG) in aqueous TiO2 suspensions was investigated. A 20 mg/L sample of MG was rapidly and completely decomposed in 3 min with the corresponding TOC removal efficiency of about 85%. To gain insight into the degradation mechanism, both GC-MS and LC-ESI-MS/MS techniques were employed to identify the major intermediates of MG degradation, including N-demethylation intermediates [(p-dimethylaminophenyl)(p-methylaminophenyl)phenylmethylium (DM-PM), (p-methylaminophenyl)(p-methylaminophenyl)phenylmethylium (MM-PM), (p-methylaminophenyl)(p-aminophenyl)phenylmethylium (M-PM)]; a decomposition compound of the conjugated structure (4-dimethylaminobenzophenone (DLBP)); products resulting from the adduct reaction of hydroxyl radical; products of benzene removal; and other open-ring intermediates such as phenol, terephthalic acid, adipic acid, benzoic acid, etc. The possible degradation mechanism of MG included five processes: the N-demethylation process, adduct products of the hydroxyl radical, the breakdown of chromophores such as destruction of the conjugated structure intermediate, removal of benzene, and an open-ring reaction. To the best of our knowledge, it is the first time the whole MG photodegradation processes have been reported.

  8. Rapid development of xylanase assay conditions using Taguchi methodology.

    PubMed

    Prasad Uday, Uma Shankar; Bandyopadhyay, Tarun Kanti; Bhunia, Biswanath

    2016-11-01

    The present investigation is mainly concerned with the rapid development of extracellular xylanase assay conditions by using Taguchi methodology. The extracellular xylanase was produced from Aspergillus niger (KP874102.1), a new strain isolated from a soil sample of the Baramura forest, Tripura West, India. Four physical parameters including temperature, pH, buffer concentration and incubation time were considered as key factors for xylanase activity and were optimized using Taguchi robust design methodology for enhanced xylanase activity. The main effect, interaction effects and optimal levels of the process factors were determined using signal-to-noise (S/N) ratio. The Taguchi method recommends the use of S/N ratio to measure quality characteristics. Based on analysis of the S/N ratio, optimal levels of the process factors were determined. Analysis of variance (ANOVA) was performed to evaluate statistically significant process factors. ANOVA results showed that temperature contributed the maximum impact (62.58%) on xylanase activity, followed by pH (22.69%), buffer concentration (9.55%) and incubation time (5.16%). Predicted results showed that enhanced xylanase activity (81.47%) can be achieved with pH 2, temperature 50°C, buffer concentration 50 Mm and incubation time 10 min.

  9. Rapid Thermal Processing (RTP) of semiconductors in space

    NASA Technical Reports Server (NTRS)

    Anderson, T. J.; Jones, K. S.

    1993-01-01

    The progress achieved on the project entitled 'Rapid Thermal Processing of Semiconductors in Space' for a 12 month period of activity ending March 31, 1993 is summarized. The activity of this group is being performed under the direct auspices of the ROMPS program. The main objective of this program is to develop and demonstrate the use of advanced robotics in space with rapid thermal process (RTP) of semiconductors providing the test technology. Rapid thermal processing is an ideal processing step for demonstration purposes since it encompasses many of the characteristics of other processes used in solid state device manufacturing. Furthermore, a low thermal budget is becoming more important in existing manufacturing practice, while a low thermal budget is critical to successful processing in space. A secondary objective of this project is to determine the influence of microgravity on the rapid thermal process for a variety of operating modes. In many instances, this involves one or more fluid phases. The advancement of microgravity processing science is an important ancillary objective.

  10. Dispersive Raman spectroscopy for the nondestructive and rapid assessment of honey quality

    NASA Astrophysics Data System (ADS)

    Mignani, A. G.; Ciaccheri, L.; Mencaglia, A. A.; Di Sanzo, R.; Carabetta, S.; Russo, M. T.

    2015-09-01

    Raman spectroscopy performed using optical fibers, with excitation at 1064 nm and a dispersive detection scheme, was utilized to measure a selection of unifloral honeys produced in the Italian region of Calabria. The honey samples had three different botanical origins: chestnut, citrus, and acacia, respectively. A multivariate processing of the spectroscopic data enabled us to distinguish their botanical origin, and to build predictive models for quantifying important nutraceutic indicators such as the main sugars and potassium. Furthermore, the Raman spectra of chestnut honeys were compared with the taste profile measured by an electronic tongue, and a good correlation to bitter/savory taste was obtained. This experiment indicates the excellent potentials of Raman spectroscopy as an analytical tool for the nondestructive and rapid assessment of food-quality indicators.

  11. A rapid alternative to X-ray crystallography for chiral determination: case studies of vibrational circular dichroism (VCD) to advance drug discovery projects.

    PubMed

    Wesolowski, Steven S; Pivonka, Don E

    2013-07-15

    The absolute stereochemistry of chiral drugs is usually established via X-ray crystallography. However, vibrational circular dichroism (VCD) spectroscopy coupled with quantum mechanics simulations offers a rapid alternative to crystallography and is readily applied to both crystalline and non-crystalline samples. VCD is an effective complement to X-ray analysis of drug candidates, and it can be used as a high-throughput means of assessing absolute stereochemistry at all phases of the discovery process (hundreds of assignments per year). The practical implementation (or fee-for-service outsourcing) of VCD and selected case studies are illustrated with an emphasis on providing utility and impact to pharmaceutical discovery programs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. A fluorimetric microplate assay for detection and quantitation of toxins causing paralytic shellfish poisoning.

    PubMed

    Louzao, Maria Carmen; Rodriguez Vieytes, Mercedes; Garcia Cabado, Ana; Vieites Baptista De Sousa, Juan Manuel; Botana, Luis Miguel

    2003-04-01

    Paralytic shellfish poisoning is one of the most severe forms of food poisoning. The toxins responsible for this type of poisoning are metabolic products of dinoflagellates, which block neuronal transmission by binding to the voltage-gated Na(+) channel. Accumulation of paralytic toxins in shellfish is an unpredictable phenomenon that necessitates the implementation of a widespread and thorough monitoring program for mollusk toxicity. All of these programs require periodical collection and analysis of a wide range of shellfish. Therefore, development of accurate analytical protocols for the rapid determination of toxicity levels would streamline this process. Our laboratory has developed a fluorimetric microplate bioassay that rapidly and specifically determines the presence of paralytic shellfish toxins in many seafood samples. This method is based on the pharmacological activity of toxins and involves several steps: (i) Incubation of excitable cells in 96 well microtiter plates with the fluorescent dye, bis-oxonol, the distribution of which across the membrane is potential-dependent. (ii) Cell depolarization with veratridine, a sodium channel-activating toxin. (iii) Dose-dependent inhibition of depolarization with saxitoxin or natural samples containing paralytic shellfish toxins. Measuring toxin-induced changes in membrane potential allowed for quantification and estimation of the toxic potency of the samples. This new approach offers significant advantages over classical methods and can be easily automated.

  13. Microbial Inactivation for Safe and Rapid Diagnostics of Infectious Samples ▿ †

    PubMed Central

    Sagripanti, Jose-Luis; Hülseweh, Birgit; Grote, Gudrun; Voß, Luzie; Böhling, Katrin; Marschall, Hans-Jürgen

    2011-01-01

    The high risk associated with biological threat agents dictates that any suspicious sample be handled under strict surety and safety controls and processed under high-level containment in specialized laboratories. This study attempted to find a rapid, reliable, and simple method for the complete inactivation of a wide range of pathogens, including spores, vegetative bacteria, and viruses, while preserving microbial nucleic acid fragments suitable for PCRs and proteinaceous epitopes for detection by immunoassays. Formaldehyde, hydrogen peroxide, and guanidium thiocyanate did not completely inactivate high titers of bacterial spores or viruses after 30 min at 21°C. Glutaraldehyde and sodium hypochlorite showed high microbicidal activity but obliterated the PCR or enzyme-linked immunosorbent assay (ELISA) detection of bacterial spores or viruses. High-level inactivation (more than 6 log10) of bacterial spores (Bacillus atrophaeus), vegetative bacteria (Pseudomonas aeruginosa), an RNA virus (the alphavirus Pixuna virus), or a DNA virus (the orthopoxvirus vaccinia virus) was attained within 30 min at 21°C by treatment with either peracetic acid or cupric ascorbate with minimal hindrance of subsequent PCR tests and immunoassays. The data described here should provide the basis for quickly rendering field samples noninfectious for further analysis under lower-level containment and considerably lower cost. PMID:21856830

  14. Rapid simultaneous determination of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, and 3,4-methylenedioxyethylamphetamine in urine by solid-phase extraction and GC-MS: a method optimized for high-volume laboratories.

    PubMed

    Stout, Peter R; Horn, Carl K; Klette, Kevin L

    2002-01-01

    To facilitate analysis of high sample volumes, an extraction, derivatization and gas chromatographic-mass spectrometric analysis method was developed to simultaneously determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxyamphetamine (MDA) 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA) in urine. This method utilized a positive-pressure manifold cation-exchange polymer-based solid-phase extraction followed by elution directly into automated liquid sampler (ALS) vials. Rapid derivatization was accomplished using heptafluorobutyric anhydride (HFBA). Recoveries averaged 90% or greater for each of the compounds. Limits of detection were 62.5 ng/mL (AMP and MDEA), 15.6 ng/mL (MAMP), and 31.3 ng/mL (MDA and MDMA) using a 2-mL sample volume. The method was linear to 5000 ng/mL for all compounds using MDMA-d5 and MAMP-d14 as internal standards. Over 200 human urine samples previously determined to contain the target analytes were analyzed using the method. Excellent agreement was seen with previous quantitations. The method was challenged with 75 potentially interfering compounds and no interferences were seen. These interfering compounds included ephedrine, pseudoephedrine, phenylpropanolamine, and phenethylamine. The method resulted in dramatic reductions in processing time and waste production.

  15. 76 FR 47216 - Expediting Research Tools to NIH Licensees Through the Use of Pay.gov for Rapid Processing of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-04

    ... NIH Licensees Through the Use of Pay.gov for Rapid Processing of Royalty Payments AGENCY: National... receipt of research tools through the use of Pay.gov for rapid processing of their royalty payments... royalty payment site within Pay.gov expedites processing times for shipment of their research tools...

  16. Non-invasive determination of glucose directly in raw fruits using a continuous flow system based on microdialysis sampling and amperometric detection at an integrated enzymatic biosensor.

    PubMed

    Vargas, E; Ruiz, M A; Campuzano, S; Reviejo, A J; Pingarrón, J M

    2016-03-31

    A non-destructive, rapid and simple to use sensing method for direct determination of glucose in non-processed fruits is described. The strategy involved on-line microdialysis sampling coupled with a continuous flow system with amperometric detection at an enzymatic biosensor. Apart from direct determination of glucose in fruit juices and blended fruits, this work describes for the first time the successful application of an enzymatic biosensor-based electrochemical approach to the non-invasive determination of glucose in raw fruits. The methodology correlates, through previous calibration set-up, the amperometric signal generated from glucose in non-processed fruits with its content in % (w/w). The comparison of the obtained results using the proposed approach in different fruits with those provided by other method involving the same commercial biosensor as amperometric detector in stirred solutions pointed out that there were no significant differences. Moreover, in comparison with other available methodologies, this microdialysis-coupled continuous flow system amperometric biosensor-based procedure features straightforward sample preparation, low cost, reduced assay time (sampling rate of 7 h(-1)) and ease of automation. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Evaluation of virus removal efficiency of coagulation-sedimentation and rapid sand filtration processes in a drinking water treatment plant in Bangkok, Thailand.

    PubMed

    Asami, Tatsuya; Katayama, Hiroyuki; Torrey, Jason Robert; Visvanathan, Chettiyappan; Furumai, Hiroaki

    2016-09-15

    In order to properly assess and manage the risk of infection by enteric viruses in tap water, virus removal efficiency should be evaluated quantitatively for individual processes in actual drinking water treatment plants (DWTPs); however, there have been only a few studies due to technical difficulties in quantifying low virus concentration in water samples. In this study, the removal efficiency of indigenous viruses was evaluated for coagulation-sedimentation (CS) and rapid sand filtration (RSF) processes in a DWTP in Bangkok, Thailand by measuring the concentration of viruses before and after treatment processes using real-time polymerase chain reaction (qPCR). Water samples were collected and concentrated from raw source water, after CS, and after RSF, and inhibitory substances in water samples were reduced by use of a hydrophobic resin (DAX-8). Pepper mild mottle virus (PMMoV) and JC polyomavirus (JC PyV) were found to be highly prevalent in raw waters, with concentrations of 10(2.88 ± 0.35) and 10(3.06 ± 0.42) copies/L (geometric mean ± S.D.), respectively. Step-wise removal efficiencies were calculated for individual processes, with some variation observed between wet and dry seasons. During the wet season, PMMoV was removed less by CS and more by RSF on average (0.40 log10 vs 1.26 log10, respectively), while the reverse was true for JC PyV (1.91 log10 vs 0.49 log10, respectively). Both viruses were removed similarly during the dry season, with CS removing the most virus (PMMoV, 1.61 log10 and 0.78 log10; JC PyV, 1.70 log10, and 0.59 log10; CS and RSF, respectively). These differences between seasons were potentially due to variations in raw water quality and the characteristics of the viruses themselves. These results suggest that PMMoV and JC PyV, which are more prevalent in environmental waters than the other enteric viruses evaluated in this study, could be useful in determining viral fate for the risk management of viruses in water treatment processes in actual full-scale DWTPs. Copyright © 2016. Published by Elsevier Ltd.

  18. Rapid and Efficient Filtration-Based Procedure for Separation and Safe Analysis of CBRN Mixed Samples

    PubMed Central

    Bentahir, Mostafa; Laduron, Frederic; Irenge, Leonid; Ambroise, Jérôme; Gala, Jean-Luc

    2014-01-01

    Separating CBRN mixed samples that contain both chemical and biological warfare agents (CB mixed sample) in liquid and solid matrices remains a very challenging issue. Parameters were set up to assess the performance of a simple filtration-based method first optimized on separate C- and B-agents, and then assessed on a model of CB mixed sample. In this model, MS2 bacteriophage, Autographa californica nuclear polyhedrosis baculovirus (AcNPV), Bacillus atrophaeus and Bacillus subtilis spores were used as biological agent simulants whereas ethyl methylphosphonic acid (EMPA) and pinacolyl methylphophonic acid (PMPA) were used as VX and soman (GD) nerve agent surrogates, respectively. Nanoseparation centrifugal devices with various pore size cut-off (30 kD up to 0.45 µm) and three RNA extraction methods (Invisorb, EZ1 and Nuclisens) were compared. RNA (MS2) and DNA (AcNPV) quantification was carried out by means of specific and sensitive quantitative real-time PCRs (qPCR). Liquid chromatography coupled to time-of-flight mass spectrometry (LC/TOFMS) methods was used for quantifying EMPA and PMPA. Culture methods and qPCR demonstrated that membranes with a 30 kD cut-off retain more than 99.99% of biological agents (MS2, AcNPV, Bacillus Atrophaeus and Bacillus subtilis spores) tested separately. A rapid and reliable separation of CB mixed sample models (MS2/PEG-400 and MS2/EMPA/PMPA) contained in simple liquid or complex matrices such as sand and soil was also successfully achieved on a 30 kD filter with more than 99.99% retention of MS2 on the filter membrane, and up to 99% of PEG-400, EMPA and PMPA recovery in the filtrate. The whole separation process turnaround-time (TAT) was less than 10 minutes. The filtration method appears to be rapid, versatile and extremely efficient. The separation method developed in this work constitutes therefore a useful model for further evaluating and comparing additional separation alternative procedures for a safe handling and preparation of CB mixed samples. PMID:24505375

  19. Flow cytometric analysis of microbial contamination in food industry technological lines--initial study.

    PubMed

    Józwa, Wojciech; Czaczyk, Katarzyna

    2012-04-02

    Flow cytometry constitutes an alternative for traditional methods of microorganisms identification and analysis, including methods requiring cultivation step. It enables the detection of pathogens and other microorganisms contaminants without the need to culture microbial cells meaning that the sample (water, waste or food e.g. milk, wine, beer) may be analysed directly. This leads to a significant reduction of time required for analysis allowing monitoring of production processes and immediate reaction in case of contamination or any disruption occurs. Apart from the analysis of raw materials or products on different stages of manufacturing process, the flow cytometry seems to constitute an ideal tool for the assessment of microbial contamination on the surface of technological lines. In the present work samples comprising smears from 3 different surfaces of technological lines from fruit and vegetable processing company from Greater Poland were analysed directly with flow cytometer. The measured parameters were forward and side scatter of laser light signals allowing the estimation of microbial cell contents in each sample. Flow cytometric analysis of the surface of food industry production lines enable the preliminary evaluation of microbial contamination within few minutes from the moment of sample arrival without the need of sample pretreatment. The presented method of fl ow cytometric initial evaluation of microbial state of food industry technological lines demonstrated its potential for developing a robust, routine method for the rapid and labor-saving detection of microbial contamination in food industry.

  20. Characterization of plastic deformation and chemical reaction in titanium-polytetrafluoroethylene mixture

    NASA Astrophysics Data System (ADS)

    Davis, Jeffery Jon

    1998-09-01

    The subject of this dissertation is the deformation process of a single metal - polymer system (titanium - polytetrafluoroethylene) and how this process leads to initiation of chemical reaction. Several different kinds of experiments were performed to characterize the behavior of this material to shock and impact. These mechanical conditions induce a rapid plastic deformation of the sample. All of the samples tested had an initial porosity which increased the plastic flow condition. It is currently believed that during the deformation process two important conditions occur: removal of the oxide layer from the metal and decomposition of the polymer. These conditions allow for rapid chemical reaction. The research from this dissertation has provided insight into the complex behavior of plastic deformation and chemical reactions in titanium - polytetrafluoroethylene (PTFE, Teflon). A hydrodynamic computational code was used to model the plastic flow for correlation with the results from the experiments. The results from this work are being used to develop an ignition and growth model for metal/polymer systems. Three sets of experiments were used to examine deformation of the 80% Ti and 20% Teflon materials: drop- weight, gas gun, and split-Hopkinson pressure bar. Recovery studies included post shot analysis of the samples using x-ray diffraction. Lagrangian hydrocode DYNA2D modeling of the drop-weight tests was performed for comparison with experiments. One of the reactions know to occur is Ti + C → TiC (s) which results in an exothermic release. However, the believed initial reactions occur between Ti and fluorine which produces TixFy gases. The thermochemical code CHEETAH was used to investigate the detonation products and concentrations possible during Ti - Teflon reaction. CHEETAH shows that the Ti - fluorine reactions are thermodynamically favorable. This research represents the most comprehensive to date study of deformation induced chemical reaction in metal/polymers.

Top