Sample records for rapid screening system

  1. Evaluation of rapid SYS system as screen for Yersinia enterocolitica in the United States.

    PubMed Central

    Mele, L; Nadler, H; Gomez, S

    1987-01-01

    Clinical isolates (n = 150) from stool specimens were selected for evaluation of the Rapid SYS system (Analytab Products, Plainview, N.Y.) as a screening test for Shigella spp., Yersinia enterocolitica, and Salmonella spp. The Gram-Negative Identification Card (Vitek Systems, Inc., Hazelwood, Mo.) was used for identification. Although acceptable performance of the Rapid SYS system was described, the interpretative criteria provided by the vendor for previous studies led to inappropriate screening for Y. enterocolitica, particularly biotype 1. When corrected screening criteria were used for the present study, the sensitivity for the detection of 76 enteric pathogens was 98.7%. Of the 76 pathogens, 1 of 21 Shigella spp. was not detected. However, specificity was only 16.6% when 72 selected nonpathogens frequently encountered in stools were eliminated. Although the Rapid SYS system can identify Shigella spp., Y. enterocolitica, and Salmonella spp., only phenylalanine deaminase-producing and cytochrome oxidase-producing organisms can be eliminated from additional testing. Therefore, the Rapid SYS system cannot be used as a three-pathogen screen in the United States or in other geographic locales where Y. enterocolitica biotype 1 may be encountered. PMID:3323232

  2. ScreenCube: A 3D Printed System for Rapid and Cost-Effective Chemical Screening in Adult Zebrafish.

    PubMed

    Monstad-Rios, Adrian T; Watson, Claire J; Kwon, Ronald Y

    2018-02-01

    Phenotype-based small molecule screens in zebrafish embryos and larvae have been successful in accelerating pathway and therapeutic discovery for diverse biological processes. Yet, the application of chemical screens to adult physiologies has been relatively limited due to additional demands on cost, space, and labor associated with screens in adult animals. In this study, we present a 3D printed system and methods for intermittent drug dosing that enable rapid and cost-effective chemical administration in adult zebrafish. Using prefilled screening plates, the system enables dosing of 96 fish in ∼3 min, with a 10-fold reduction in drug quantity compared to that used in previous chemical screens in adult zebrafish. We characterize water quality kinetics during immersion in the system and use these kinetics to rationally design intermittent dosing regimens that result in 100% fish survival. As a demonstration of system fidelity, we show the potential to identify two known chemical inhibitors of adult tail fin regeneration, cyclopamine and dorsomorphin. By developing methods for rapid and cost-effective chemical administration in adult zebrafish, this study expands the potential for small molecule discovery in postembryonic models of development, disease, and regeneration.

  3. Optically Based Rapid Screening Method for Proven Optimal Treatment Strategies Before Treatment Begins

    DTIC Science & Technology

    to rapidly test /screen breast cancer therapeutics as a strategy to streamline drug development and provide individualized treatment. The results...system can therefore be used to streamline pre-clinical drug development, by reducing the number of animals , cost, and time required to screen new drugs

  4. Rapid antibiotic efficacy screening with aluminum oxide nanoporous membrane filter-chip and optical detection system.

    PubMed

    Tsou, Pei-Hsiang; Sreenivasappa, Harini; Hong, Sungmin; Yasuike, Masayuki; Miyamoto, Hiroshi; Nakano, Keiyo; Misawa, Takeyuki; Kameoka, Jun

    2010-09-15

    We have developed a filter-chip and optical detection system for rapid antibiotic efficacy screening. The filter-chip consisted of a 1-mL reservoir and an anodic aluminum oxide (AAO) nanoporous membrane. Sample solution with liquid growth media, bacteria, and antibiotics was incubated in the reservoir for a specific period of time. The number of live bacteria on the surface of membrane was counted after the incubation with antibiotics and filtration. Using this biosensing system, we have demonstrated a 1-h antibiotic screening for patients' clinical samples, significantly faster than the conventional antibiotic susceptibility tests that typically take more than 24h. This rapid screening nature makes the filter-chip and detection system ideal for tailoring antibiotic treatment to individual patients by reducing the microbial antibiotic resistance, and improving the survival rate for patients suffering from postoperative infections. Published by Elsevier B.V.

  5. DEMONSTRATION BULLETIN: RAPID OPTICAL SCREEN TOOL (ROST™) - LORAL CORPORATION

    EPA Science Inventory

    The Loral Rapid Optical Screen Tool (ROST™) is a tunable dye laser system used for the detection of petroleum, semi-volatile, and some volatile organic compounds in soils. The technology is used in conjunction with a cone penetrometer (CP).

  6. Rapid, sensitive and reproducible method for point-of-collection screening of liquid milk for adulterants using a portable Raman spectrometer with novel optimized sample well

    NASA Astrophysics Data System (ADS)

    Nieuwoudt, Michel K.; Holroyd, Steve E.; McGoverin, Cushla M.; Simpson, M. Cather; Williams, David E.

    2017-02-01

    Point-of-care diagnostics are of interest in the medical, security and food industry, the latter particularly for screening food adulterated for economic gain. Milk adulteration continues to be a major problem worldwide and different methods to detect fraudulent additives have been investigated for over a century. Laboratory based methods are limited in their application to point-of-collection diagnosis and also require expensive instrumentation, chemicals and skilled technicians. This has encouraged exploration of spectroscopic methods as more rapid and inexpensive alternatives. Raman spectroscopy has excellent potential for screening of milk because of the rich complexity inherent in its signals. The rapid advances in photonic technologies and fabrication methods are enabling increasingly sensitive portable mini-Raman systems to be placed on the market that are both affordable and feasible for both point-of-care and point-of-collection applications. We have developed a powerful spectroscopic method for rapidly screening liquid milk for sucrose and four nitrogen-rich adulterants (dicyandiamide (DCD), ammonium sulphate, melamine, urea), using a combined system: a small, portable Raman spectrometer with focusing fibre optic probe and optimized reflective focusing wells, simply fabricated in aluminium. The reliable sample presentation of this system enabled high reproducibility of 8% RSD (residual standard deviation) within four minutes. Limit of detection intervals for PLS calibrations ranged between 140 - 520 ppm for the four N-rich compounds and between 0.7 - 3.6 % for sucrose. The portability of the system and reliability and reproducibility of this technique opens opportunities for general, reagentless adulteration screening of biological fluids as well as milk, at point-of-collection.

  7. A web-based platform for virtual screening.

    PubMed

    Watson, Paul; Verdonk, Marcel; Hartshorn, Michael J

    2003-09-01

    A fully integrated, web-based, virtual screening platform has been developed to allow rapid virtual screening of large numbers of compounds. ORACLE is used to store information at all stages of the process. The system includes a large database of historical compounds from high throughput screenings (HTS) chemical suppliers, ATLAS, containing over 3.1 million unique compounds with their associated physiochemical properties (ClogP, MW, etc.). The database can be screened using a web-based interface to produce compound subsets for virtual screening or virtual library (VL) enumeration. In order to carry out the latter task within ORACLE a reaction data cartridge has been developed. Virtual libraries can be enumerated rapidly using the web-based interface to the cartridge. The compound subsets can be seamlessly submitted for virtual screening experiments, and the results can be viewed via another web-based interface allowing ad hoc querying of the virtual screening data stored in ORACLE.

  8. Rapid microfluidic analysis of a Y-STR multiplex for screening of forensic samples.

    PubMed

    Gibson-Daw, Georgiana; Albani, Patricia; Gassmann, Marcus; McCord, Bruce

    2017-02-01

    In this paper, we demonstrate a rapid analysis procedure for use with a small set of rapidly mutating Y chromosomal short tandem repeat (Y-STR) loci that combines both rapid polymerase chain reaction (PCR) and microfluidic separation elements. The procedure involves a high-speed polymerase and a rapid cycling protocol to permit PCR amplification in 16 min. The resultant amplified sample is next analysed using a short 1.8-cm microfluidic electrophoresis system that permits a four-locus Y-STR genotype to be produced in 80 s. The entire procedure takes less than 25 min from sample collection to result. This paper describes the rapid amplification protocol as well as studies of the reproducibility and sensitivity of the procedure and its optimisation. The amplification process utilises a small high-speed thermocycler, microfluidic device and compact laptop, making it portable and potentially useful for rapid, inexpensive on-site genotyping. The four loci used for the multiplex were selected due to their rapid mutation rates and should proved useful in preliminary screening of samples and suspects. Overall, this technique provides a method for rapid sample screening of suspect and crime scene samples in forensic casework. Graphical abstract ᅟ.

  9. Microfluidic Devices for Drug Delivery Systems and Drug Screening

    PubMed Central

    Kompella, Uday B.; Damiati, Safa A.

    2018-01-01

    Microfluidic devices present unique advantages for the development of efficient drug carrier particles, cell-free protein synthesis systems, and rapid techniques for direct drug screening. Compared to bulk methods, by efficiently controlling the geometries of the fabricated chip and the flow rates of multiphase fluids, microfluidic technology enables the generation of highly stable, uniform, monodispersed particles with higher encapsulation efficiency. Since the existing preclinical models are inefficient drug screens for predicting clinical outcomes, microfluidic platforms might offer a more rapid and cost-effective alternative. Compared to 2D cell culture systems and in vivo animal models, microfluidic 3D platforms mimic the in vivo cell systems in a simple, inexpensive manner, which allows high throughput and multiplexed drug screening at the cell, organ, and whole-body levels. In this review, the generation of appropriate drug or gene carriers including different particle types using different configurations of microfluidic devices is highlighted. Additionally, this paper discusses the emergence of fabricated microfluidic cell-free protein synthesis systems for potential use at point of care as well as cell-, organ-, and human-on-a-chip models as smart, sensitive, and reproducible platforms, allowing the investigation of the effects of drugs under conditions imitating the biological system. PMID:29462948

  10. Public Health Surveillance via Template Management in Electronic Health Records: Tri-Service Workflow's Rapid Response to an Infectious Disease Crisis.

    PubMed

    Berkley, Holly; Barnes, Matthew; Carnahan, David; Hayhurst, Janet; Bockhorst, Archie; Neville, James

    2017-03-01

    To describe the use of template-based screening for risk of infectious disease exposure of patients presenting to primary care medical facilities during the 2014 West African Ebola virus outbreak. The Military Health System implemented an Ebola risk-screening tool in primary care settings in order to create early notifications and early responses to potentially infected persons. Three time-sensitive, evidence-based screening questions were developed and posted to Tri-Service Workflow (TSWF) AHLTA templates in conjunction with appropriate training. Data were collected in January 2015, to assess the adoption of the TSWF-based Ebola risk-screening tool. Among encounters documented using TSWF templates, 41% of all encounters showed use of the TSWF-based Ebola risk-screening questions by the fourth day. The screening rate increased over the next 3 weeks, and reached a plateau at approximately 50%. This report demonstrates the MHS capability to deploy a standardized, globally applicable decision support aid that could be seen the same day by all primary care clinics across the military health direct care system, potentially improving rapid compliance with screening directives. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  11. Role of re-screening of cervical smears in internal quality control.

    PubMed Central

    Baker, A; Melcher, D; Smith, R

    1995-01-01

    AIMS--To investigate the use of rapid re-screening as a quality control method for previously screened cervical slides; to compare this method with 10% random re-screening and clinically indicated double screening. METHODS--Between June 1990 and December 1994, 117,890 negative smears were subjected to rapid re-screening. RESULTS--This study shows that rapid re-screening detects far greater numbers of false negative cases when compared with both 10% random re-screening and clinically indicated double screening, with no additional demand on human resources. The technique also identifies variation in the performance of screening personnel as an additional benefit. CONCLUSION--Rapid re-screening is an effective method of quality control. Although less sensitive, rapid re-screening should replace 10% random re-screening and selected re-screening as greater numbers of false negative results are detected while consuming less resources. PMID:8543619

  12. Meniscus Membranes For Separation

    DOEpatents

    Dye, Robert C.; Jorgensen, Betty; Pesiri, David R.

    2005-09-20

    Gas separation membranes, especially meniscus-shaped membranes for gas separations are disclosed together with the use of such meniscus-shaped membranes for applications such as thermal gas valves, pre-concentration of a gas stream, and selective pre-screening of a gas stream. In addition, a rapid screening system for simultaneously screening polymer materials for effectiveness in gas separation is provided.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shattan, Michael; Stowe, Ashley; McIntosh, Kathryn

    Explore feasibility of portable LIBS and micro-XRF systems as methods of field screening for real debris; Develop a LIBS Capability to rapidly screen beads for production quality control; Complete 3D elemental mapping of surrogate debris to determine uranium and other elemental migration patterns during debris formation

  14. Rapid screening for inflammatory neuropathies by standardized clinical criteria

    PubMed Central

    Tramontozzi, Louis A.

    2016-01-01

    Abstract Background: Delay in recognition and treatment of inflammatory neuropathies increases morbidity and mortality. We have developed and standardized 3 clinical screening criteria that rapidly detect inflammatory neuropathies. Methods: We reviewed all patients with definite large fiber neuropathy in 2 different patient populations: 1 from a private neurology clinic and the other from a tertiary care center. Patients were divided into 2 groups: those with an inflammatory neuropathy and those with a noninflammatory neuropathy. We specifically noted the 3 key neuropathy characteristics: onset, distribution, and associated systemic features (ODS). We studied the sensitivity and specificity of ODS in differentiating between inflammatory and noninflammatory neuropathies. Results: A total of 206 patients were included: 51 from the private clinic and 155 from the tertiary care center. The sensitivity of using ODS in detecting an inflammatory neuropathy was 96% and the specificity was 85%. The positive predictive value of ODS was 0.8 and negative predictive value was 0.97. Conclusions: Rapid screening for inflammatory neuropathies by ODS clinical criteria is highly sensitive and has a high negative predictive value for noninflammatory neuropathies. ODS uses simple clinical criteria to rapidly screen for patients with a potentially treatable form of neuropathy and accelerate their diagnostic evaluation. Classification of evidence: This study provides Class IV evidence that 3 neuropathy characteristics—onset, distribution, and associated systemic features—accurately identify patients with inflammatory neuropathies. PMID:29443273

  15. Rapid Screening of Natural Plant Extracts with Calcium Diacetate for Differential Effects Against Foodborne Pathogens and a Probiotic Bacterium.

    PubMed

    Colonna, William; Brehm-Stecher, Byron; Shetty, Kalidas; Pometto, Anthony

    2017-12-01

    This study focused on advancing a rapid turbidimetric bioassay to screen antimicrobials using specific cocktails of targeted foodborne bacterial pathogens. Specifically, to show the relevance of this rapid screening tool, the antimicrobial potential of generally recognized as safe calcium diacetate (DAX) and blends with cranberry (NC) and oregano (OX) natural extracts was evaluated. Furthermore, the same extracts were evaluated against beneficial lactic acid bacteria. The targeted foodborne pathogens evaluated were Escherichia coli O157:H7, Salmonella spp., Listeria monocytogenes, and Staphylococcus aureus using optimized initial cocktails (∼10 8 colony-forming unit/mL) containing strains isolated from human food outbreaks. Of all extracts evaluated, 0.51% (w/v) DAX in ethanol was the most effective against all four pathogens. However, DAX when reduced to 0.26% and with added blends from ethanol extractions consisting of DAX:OX (3:1), slightly outperformed or was equal to same levels of DAX alone. Subculture of wells in which no growth occurred after 1 week indicated that all water and ethanol extracts were bacteriostatic against the pathogens tested. All the targeted antimicrobials had no effect on the probiotic organism Lactobacillus plantarum. The use of such rapid screening methods combined with the use of multistrain cocktails of targeted foodborne pathogens from outbreaks will allow rapid large-scale screening of antimicrobials and enable further detailed studies in targeted model food systems.

  16. A Rapid Screen for Host-Encoded miRNAs with Inhibitory Effects against Ebola Virus Using a Transcription- and Replication-Competent Virus-Like Particle System.

    PubMed

    Wang, Zhongyi; Li, Jiaming; Fu, Yingying; Zhao, Zongzheng; Zhang, Chunmao; Li, Nan; Li, Jingjing; Cheng, Hongliang; Jin, Xiaojun; Lu, Bing; Guo, Zhendong; Qian, Jun; Liu, Linna

    2018-05-16

    MicroRNAs (miRNAs) may become efficient antiviral agents against the Ebola virus (EBOV) targeting viral genomic RNAs or transcripts. We previously conducted a genome-wide search for differentially expressed miRNAs during viral replication and transcription. In this study, we established a rapid screen for miRNAs with inhibitory effects against EBOV using a tetracistronic transcription- and replication-competent virus-like particle (trVLP) system. This system uses a minigenome comprising an EBOV leader region, luciferase reporter, VP40, GP, VP24, EBOV trailer region, and three noncoding regions from the EBOV genome and can be used to model the life cycle of EBOV under biosafety level (BSL) 2 conditions. Informatic analysis was performed to select up-regulated miRNAs targeting the coding regions of the minigenome with the highest binding energy to perform inhibitory effect screening. Among these miRNAs, miR-150-3p had the most significant inhibitory effect. Reverse transcription polymerase chain reaction (RT-PCR), Western blot, and double fluorescence reporter experiments demonstrated that miR-150-3p inhibited the reproduction of trVLPs via the regulation of GP and VP40 expression by directly targeting the coding regions of GP and VP40. This novel, rapid, and convenient screening method will efficiently facilitate the exploration of miRNAs against EBOV under BSL-2 conditions.

  17. Rapid Screening and Characterization of Acetylcholinesterase Inhibitors from Yinhuang Oral Liquid Using Ultrafiltration-liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry

    PubMed Central

    Zhang, Haomin; Guo, Yinan; Meng, Lingwen; Sun, Hui; Yang, Yinping; Gao, Ying; Sun, Jiaming

    2018-01-01

    Background: At present, approximately 17–25 million people in the world suffer from Alzheimer's disease (AD). The most efficacious and acceptable therapeutic drug clinically are the acetylcholinesterase inhibitors (AChEIs). Yinhuang oral liquid is a Chinese medicine preparation which contains AChEIs according to the literatures. However, no strategy has been presented for rapid screening and identification of AChEIs from Yinhuang oral liquid. Objective: To develop a method for rapid screening and identification of AChEIs from Yinhuang oral liquid using ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry (UF-LC-ESI-MS/MS). Materials and Methods: In this study, UF incubation conditions such as enzyme concentration, incubation time, and incubation temperature were optimized so as to get better screening results. The AChEIs from Yinhuang oral liquid were identified by high-performance liquid chromatography-ESI-MS and the improved Ellman method was used for the AChE inhibitory activity test in vitro. Results: The results showed that Yinhuang oral liquid can inhibit the activity of AChE. We screened and identified seven compounds with potential AChE inhibitory activity from Yinhuang oral liquid, which provided experimental basis for the treatment and prevention of AD. Conclusion: The current technique was used to directly screen the active ingredients with acetylcholinesterase inhibition from complex traditional Chinese medicine, which was simple, rapid, accurate, and suitable for high-throughput screening of AChEI from complex systems. SUMMARY A UF-LC-ESI-MS/MS method for rapid screening and identification of AChEIs from Yinhuang oral liquid was developedSeven compounds were screened and identified with potential AChE inhibitory activity from Yinhuang oral liquidIt provided experimental basis of Yinhuang oral liquid for the treating and preventing AD. Abbreviations used: (AD): Alzheimer's disease; (UF-LC-ESI-MS/MS): ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry; (AChEIs): acetylcholinesterase inhibitors. PMID:29720840

  18. In Vitro Toxicity Screening Technique for Volatile Substances Using Flow-Through System@@

    EPA Science Inventory

    In 2007, the National Research Council envisioned the need for inexpensive, rapid, cell-based toxicity testing methods relevant to human health. in vitro screening approaches have largely addressed these problems by using robotics and automation. However, the challenge is that ma...

  19. Use of a parasitic wasp as a biosensor

    USDA-ARS?s Scientific Manuscript database

    Screening cargo for illicit substances is still in need of high-throughput inspection systems that can rapidly screen and accurately identify suspicious cargo. Here we investigate the ability of a parasitic wasp, Microplitis croceipes to detect and respond to methyl benzoate, the volatile component ...

  20. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    PubMed

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  1. Telemedicine optoelectronic biomedical data processing system

    NASA Astrophysics Data System (ADS)

    Prosolovska, Vita V.

    2010-08-01

    The telemedicine optoelectronic biomedical data processing system is created to share medical information for the control of health rights and timely and rapid response to crisis. The system includes the main blocks: bioprocessor, analog-digital converter biomedical images, optoelectronic module for image processing, optoelectronic module for parallel recording and storage of biomedical imaging and matrix screen display of biomedical images. Rated temporal characteristics of the blocks defined by a particular triggering optoelectronic couple in analog-digital converters and time imaging for matrix screen. The element base for hardware implementation of the developed matrix screen is integrated optoelectronic couples produced by selective epitaxy.

  2. Development of an Automated Microfluidic Reaction Platform for Multidimensional Screening: Reaction Discovery Employing Bicyclo[3.2.1]octanoid Scaffolds

    PubMed Central

    Goodell, John R.; McMullen, Jonathan P.; Zaborenko, Nikolay; Maloney, Jason R.; Ho, Chuan-Xing; Jensen, Klavs F.; Porco, John A.

    2010-01-01

    An automated, silicon-based microreactor system has been developed for rapid, low-volume, multidimensional reaction screening. Use of the microfluidic platform to identify transformations of densely functionalized bicyclo[3.2.1]octanoid scaffolds will be described. PMID:20560568

  3. Screening for chemicals that affect hair cell death and survival in the zebrafish lateral line.

    PubMed

    Ou, Henry; Simon, Julian A; Rubel, Edwin W; Raible, David W

    2012-06-01

    The zebrafish lateral line is an efficient model system for the evaluation of chemicals that protect and damage hair cells. Located on the surface of the body, lateral line hair cells are accessible for manipulation and visualization. The zebrafish lateral line system allows rapid screens of large chemical libraries, as well as subsequent thorough evaluation of interesting compounds. In this review, we focus on the results of our previous screens and the evolving methodology of our screens for chemicals that protect hair cells, and chemicals that damage hair cells using the zebrafish lateral line. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Electrochemical sensor for multiplex screening of genetically modified DNA: identification of biotech crops by logic-based biomolecular analysis.

    PubMed

    Liao, Wei-Ching; Chuang, Min-Chieh; Ho, Ja-An Annie

    2013-12-15

    Genetically modified (GM) technique, one of the modern biomolecular engineering technologies, has been deemed as profitable strategy to fight against global starvation. Yet rapid and reliable analytical method is deficient to evaluate the quality and potential risk of such resulting GM products. We herein present a biomolecular analytical system constructed with distinct biochemical activities to expedite the computational detection of genetically modified organisms (GMOs). The computational mechanism provides an alternative to the complex procedures commonly involved in the screening of GMOs. Given that the bioanalytical system is capable of processing promoter, coding and species genes, affirmative interpretations succeed to identify specified GM event in terms of both electrochemical and optical fashions. The biomolecular computational assay exhibits detection capability of genetically modified DNA below sub-nanomolar level and is found interference-free by abundant coexistence of non-GM DNA. This bioanalytical system, furthermore, sophisticates in array fashion operating multiplex screening against variable GM events. Such a biomolecular computational assay and biosensor holds great promise for rapid, cost-effective, and high-fidelity screening of GMO. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Rapid automated method for screening of enteric pathogens from stool specimens.

    PubMed Central

    Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C

    1987-01-01

    A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230

  6. Screening and identification of radical scavengers from Neo-Taraxacum siphonanthum by online rapid screening method and nuclear magnetic resonance experiments.

    PubMed

    Shi, Shu Yun; Zhang, Yu Ping; Zhou, Hong Hao; Huang, Ke Long; Jiang, Xin Yu

    2010-01-01

    An online rapid screening method, the high-performance liquid chromatography (HPLC)-diode array detector (DAD)-radical scavenging detection (RSD)-electrospray ionization (ESI)-mass spectroscopy (MS)/MS system, was developed for the screening and identification of radical scavengers from Neo-Taraxacum siphonanthum, a new species found in China in 1989. For further characterization, the target compounds were isolated by silica column chromatography, preparative high-performance liquid chromatography (HPLC), HSCCC, and Sephadex LH-20 column chromatography and elucidated on the basis of ultraviolet (UV), ESI-MS/MS, and nuclear magnetic resonance (NMR) spectroscopy, as well as the chemical analysis. Eighteen antioxidative polyphenols (5 caffeic acid derivatives and 13 flavonoid derivatives) were characterized from Neo-T. siphonanthum. The distribution of all compounds was discussed in a chemosystematic context, which suggested that the genera Neo-Taraxacum and Taraxacum might relate chemosystematically.

  7. Assessing blood vessel perfusion and vital signs through retinal imaging photoplethysmography.

    PubMed

    Hassan, Harnani; Jaidka, Sheila; Dwyer, Vincent M; Hu, Sijung

    2018-05-01

    One solution to the global challenge of increasing ocular disease is a cost-effective technique for rapid screening and assessment. Current ophthalmic imaging techniques, e.g. scanning and ocular blood flow systems, are expensive, complex to operate and utilize invasive contrast agents during assessment. The work presented here demonstrates a simple retinal imaging photoplethysmography (iPPG) system with the potential to provide screening, diagnosis, monitoring and assessment that is non-invasive, painless and radiationless. Time series of individual retinal blood vessel images, captured with an eye fundus camera, are processed using standard filtering, amplitude demodulation and principle component analysis (PCA) methods to determine the values of the heart rate (HR) and respiration rate (RR), which are in compliance with simultaneously obtained measurements using commercial pulse oximetry. It also seems possible that some information on the dynamic changes in oxygen saturation levels ( SpO 2 ) in a retinal blood vessel may also be obtained. As a consequence, the retinal iPPG modality system demonstrates a potential avenue for rapid ophthalmic screening, and even early diagnosis, against ocular disease without the need for fluorescent or contrast agents.

  8. Comparison of two commercially available rapid detection methods and a conventional culture method to detect naturally occurring salmonellae on broiler carcasses

    USDA-ARS?s Scientific Manuscript database

    Many different screening devices and sampling methods have been used to detect the presence of naturally occurring Salmonella on commercially processed broiler carcasses. The objective of this study was to compare two commercial screening systems (BAX® and Roka®) to a standard cultural procedure use...

  9. Probe molecules (PrM) approach in adverse outcome pathway (AOP) based high throughput screening (HTS): in vivo discovery for developing in vitro target methods

    EPA Science Inventory

    Efficient and accurate adverse outcome pathway (AOP) based high-throughput screening (HTS) methods use a systems biology based approach to computationally model in vitro cellular and molecular data for rapid chemical prioritization; however, not all HTS assays are grounded by rel...

  10. BIOHAZ: Rapid On-Site Biological Detection for First Responders

    DTIC Science & Technology

    2001-09-01

    numbers comprise the compilation report: ADP013371 thru ADP013468 UNCLASSIFIED 84. BIORAZ: Rapid On- Site Biological Detection for First Responders Randall... responders an integated capability to collect an environmental sample and to rapidly screen that sample on site for the presence of biological material. This...further analyzed on site with immunoassay tickets before being sent to a laboratory. This system provides the emergency responders with a capability that

  11. The planning and establishment of a sample preparation laboratory for drug discovery

    PubMed Central

    Dufresne, Claude

    2000-01-01

    Nature has always been a productive source of new drugs. With the advent of high-throughput screening, it has now become possible to rapidly screen large sample collections. In addition to seeking greater diversity from natural product sources (micro-organisms, plants, etc.), fractionation of the crude extracts prior to screening is becoming a more important part of our efforts. As sample preparation protocols become more involved, automation can help to achieve and maintain a desired sample throughput. To address the needs of our screening program, two robotic systems were designed. The first system processes crude extracts all the way to 96-well plates, containing solutions suitable for screening in biological and biochemical assays. The system can dissolve crude extracts, fractionate them on solid-phase extraction cartridges, dry and weigh each fraction, re-dissolve them to a known concentration, and prepare mother plates. The second system replicates mother plates into a number of daughter plates. PMID:18924691

  12. A novel system for spatial and temporal imaging of intrinsic plant water use efficiency.

    PubMed

    McAusland, L; Davey, P A; Kanwal, N; Baker, N R; Lawson, T

    2013-11-01

    Instrumentation and methods for rapid screening and selection of plants with improved water use efficiency are essential to address current issues of global food and fuel security. A new imaging system that combines chlorophyll fluorescence and thermal imaging has been developed to generate images of assimilation rate (A), stomatal conductance (gs), and intrinsic water use efficiency (WUEi) from whole plants or leaves under controlled environmental conditions. This is the first demonstration of the production of images of WUEi and the first to determine images of g s from themography at the whole-plant scale. Data are presented illustrating the use of this system for rapidly and non-destructively screening plants for alterations in WUEi by comparing Arabidopsis thaliana mutants (OST1-1) that have altered WUEi driven by open stomata, with wild-type plants. This novel instrument not only provides the potential to monitor multiple plants simultaneously, but enables intra- and interspecies variation to be taken into account both spatially and temporally. The ability to measure A, gs, and WUEi progressively was developed to facilitate and encourage the development of new dynamic protocols. Images illustrating the instrument's dynamic capabilities are demonstrated by analysing plant responses to changing photosynthetic photon flux density (PPFD). Applications of this system will augment the research community's need for novel screening methods to identify rapidly novel lines, cultivars, or species with improved A and WUEi in order to meet the current demands on modern agriculture and food production.

  13. Lung Cancer Screening With Low-Dose CT: Implementation Amid Changing Public Policy at One Health Care System.

    PubMed

    Begnaud, Abbie; Hall, Thomas; Allen, Tadashi

    2016-01-01

    Screening for lung cancer with low-dose CT has evolved rapidly in recent years since the National Lung Screening Trial (NLST) results. Subsequent professional and governmental organization guidelines have shaped policy and reimbursement for the service. Increasingly available guidance describes eligible patients and components necessary for a high-quality lung cancer screening program; however, practical instruction and implementation experience is not widely reported. We launched a lung cancer screening program in the face of reimbursement and guideline uncertainties at a large academic health center. We report our experience with implementation, including challenges and proposed solutions. Initially, we saw less referrals than expected for screening, and many patients referred for screening did not clearly meet eligibility guidelines. We educated primary care providers and implemented system tools to encourage referral of eligible patients. Moreover, in response to the Centers for Medicare & Medicaid Services (CMS) final coverage determination, we report our programmatic adaptation to meet these requirements. In addition to the components common to all quality programs, individual health delivery systems will face unique barriers related to patient population, available resources, and referral patterns.

  14. iScreen: world's first cloud-computing web server for virtual screening and de novo drug design based on TCM database@Taiwan

    NASA Astrophysics Data System (ADS)

    Tsai, Tsung-Ying; Chang, Kai-Wei; Chen, Calvin Yu-Chian

    2011-06-01

    The rapidly advancing researches on traditional Chinese medicine (TCM) have greatly intrigued pharmaceutical industries worldwide. To take initiative in the next generation of drug development, we constructed a cloud-computing system for TCM intelligent screening system (iScreen) based on TCM Database@Taiwan. iScreen is compacted web server for TCM docking and followed by customized de novo drug design. We further implemented a protein preparation tool that both extract protein of interest from a raw input file and estimate the size of ligand bind site. In addition, iScreen is designed in user-friendly graphic interface for users who have less experience with the command line systems. For customized docking, multiple docking services, including standard, in-water, pH environment, and flexible docking modes are implemented. Users can download first 200 TCM compounds of best docking results. For TCM de novo drug design, iScreen provides multiple molecular descriptors for a user's interest. iScreen is the world's first web server that employs world's largest TCM database for virtual screening and de novo drug design. We believe our web server can lead TCM research to a new era of drug development. The TCM docking and screening server is available at http://iScreen.cmu.edu.tw/.

  15. iScreen: world's first cloud-computing web server for virtual screening and de novo drug design based on TCM database@Taiwan.

    PubMed

    Tsai, Tsung-Ying; Chang, Kai-Wei; Chen, Calvin Yu-Chian

    2011-06-01

    The rapidly advancing researches on traditional Chinese medicine (TCM) have greatly intrigued pharmaceutical industries worldwide. To take initiative in the next generation of drug development, we constructed a cloud-computing system for TCM intelligent screening system (iScreen) based on TCM Database@Taiwan. iScreen is compacted web server for TCM docking and followed by customized de novo drug design. We further implemented a protein preparation tool that both extract protein of interest from a raw input file and estimate the size of ligand bind site. In addition, iScreen is designed in user-friendly graphic interface for users who have less experience with the command line systems. For customized docking, multiple docking services, including standard, in-water, pH environment, and flexible docking modes are implemented. Users can download first 200 TCM compounds of best docking results. For TCM de novo drug design, iScreen provides multiple molecular descriptors for a user's interest. iScreen is the world's first web server that employs world's largest TCM database for virtual screening and de novo drug design. We believe our web server can lead TCM research to a new era of drug development. The TCM docking and screening server is available at http://iScreen.cmu.edu.tw/.

  16. The cost-effectiveness of predonation screening for transfusion transmissible infections using rapid test kits in a hospital-based blood transfusion centre.

    PubMed

    Dosunmu, Adedoyin Owolabi; Akinbami, Akinsegun Abduljaleel; Ismail, Ayobami Kamal; Olaiya, Modupe Adebimpe; Uche, Ebele Ifeyinwa; Aile, Igbinoba Kingsley

    2017-01-01

    Blood transfusion practice emphasises safety, efficacy and appropriate use. These require cost-effective programme management. This study focused on the cost of screening for transfusion transmissible infections (TTI). This was a 1 year (2016) analysis of screening in a hospital-based transfusion centre. The cost of screening all blood donors by ELISA was compared to the cost of serial screening starting from rapid kit, taking into account, the estimated cost of blood bags prevented from discard after ELISA screening (attributable cost). The cost of voluntary donor drive plus cost of ELISA screening was compared with the present cost of screening. A total of 5591 donors were screened for HIV, hepatitis B and C using the rapid kit, 291 donors were deferred (5.2%). A total of 5300 units were further screened by ELISA. A total of 435 blood units (8.2%) were discarded due to TTI positivity. TTI positivity rate was 12.98%. Only 2.36% were voluntary donors and among these 9.1% were TTI positive. The attributable cost of serial screening was 55,653.5 USD while that of screening by ELISA only was 55,910 USD. The attributable cost of rapid screening for only hepatitis B and then ELISA was 53,313.9 USD taking into consideration that 187 blood units would be prevented from undue discard. This analysis demonstrated that with proper donor selection, rapid screening for hepatitis B virus only before ELISA screening is more cost-effective. This will also reduce the waiting time for donors and counselling if HIV positive.

  17. Development and Verification of a Mobile Shelter Assessment System "Rapid Assessment System of Evacuation Center Condition Featuring Gonryo and Miyagi (RASECC-GM)" for Major Disasters.

    PubMed

    Ishii, Tadashi; Nakayama, Masaharu; Abe, Michiaki; Takayama, Shin; Kamei, Takashi; Abe, Yoshiko; Yamadera, Jun; Amito, Koichiro; Morino, Kazuma

    2016-10-01

    Introduction There were 5,385 deceased and 710 missing in the Ishinomaki medical zone following the Great East Japan Earthquake that occurred in Japan on March 11, 2011. The Ishinomaki Zone Joint Relief Team (IZJRT) was formed to unify the relief teams of all organizations joining in support of the Ishinomaki area. The IZJRT expanded relief activity as they continued to manually collect and analyze assessments of essential information for maintaining health in all 328 shelters using a paper-type survey. However, the IZJRT spent an enormous amount of time and effort entering and analyzing these data because the work was vastly complex. Therefore, an assessment system must be developed that can tabulate shelter assessment data correctly and efficiently. The objective of this report was to describe the development and verification of a system to rapidly assess evacuation centers in preparation for the next major disaster. Report Based on experiences with the complex work during the disaster, software called the "Rapid Assessment System of Evacuation Center Condition featuring Gonryo and Miyagi" (RASECC-GM) was developed to enter, tabulate, and manage the shelter assessment data. Further, a verification test was conducted during a large-scale Self-Defense Force (SDF) training exercise to confirm its feasibility, usability, and accuracy. The RASECC-GM comprises three screens: (1) the "Data Entry screen," allowing for quick entry on tablet devices of 19 assessment items, including shelter administrator, living and sanitary conditions, and a tally of the injured and sick; (2) the "Relief Team/Shelter Management screen," for registering information on relief teams and shelters; and (3) the "Data Tabulation screen," which allows tabulation of the data entered for each shelter, as well as viewing and sorting from a disaster headquarters' computer. During the verification test, data of mock shelters entered online were tabulated quickly and accurately on a mock disaster headquarters' computer. Likewise, data entered offline also were tabulated quickly on the mock disaster headquarters' computer when the tablet device was moved into an online environment. The RASECC-GM, a system for rapidly assessing the condition of evacuation centers, was developed. Tests verify that users of the system would be able to easily, quickly, and accurately assess vast quantities of data from multiple shelters in a major disaster and immediately manage the inputted data at the disaster headquarters. Ishii T , Nakayama M , Abe M , Takayama S , Kamei T , Abe Y , Yamadera J , Amito K , Morino K . Development and verification of a mobile shelter assessment system "Rapid Assessment System of Evacuation Center Condition featuring Gonryo and Miyagi (RASECC-GM)" for major disasters. Prehosp Disaster Med. 2016;31(5):539-546.

  18. Development of rectal self-emulsifying suspension of a moisture-labile water-soluble drug.

    PubMed

    Kauss, Tina; Gaubert, Alexandra; Tabaran, Luc; Tonelli, Giovanni; Phoeung, Thida; Langlois, Marie-Hélène; White, Nick; Cartwright, Anthony; Gomes, Melba; Gaudin, Karen

    2018-01-30

    Self-emulsifying drug delivery systems, commonly used for oral delivery of poorly soluble compounds, were used to formulate water soluble but moisture labile compounds for rectal application. The objective was to use the oily phase of the system to formulate a liquid, non-aqueous product while obtaining the advantages of self-emulsification, rapid contact with the rectal mucosa and rapid absorption post-administration. Ceftriaxone was used as a model drug and the human bile salt sodium chenodeoxycholate was used as an absorption enhancer. After preliminary screening of 23 excipients, based on their emulsification ability and emulsion fineness in binary and ternary mixtures, a full factorial design was used to screen different formulations of three preselected excipients. The optimal formulation contained 60% of excipients, namely Capryol 90, Kolliphor EL and Kolliphor PS20 in 4 : 6 : 6 ratio and 40% of a powder blend that included 500 mg of ceftriaxone. Characterization of the system showed that it complied with the requirements for rectal administration, in particular rapid emulsification in a small quantity of liquid. Rabbit bioavailability showed rapid absorption of ceftriaxone, achieving 128% bioavailability compared to powder control formulation. These results demonstrated the potential of self-emulsifying formulations for rectal administration of Class 3 BCS drugs. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  19. Prevention of blood-borne HIV transmission using a decentralized approach in Shaba, Zaire.

    PubMed

    Laleman, G; Magazani, K; Perriëns, J H; Badibanga, N; Kapila, N; Konde, M; Selemani, U; Piot, P

    1992-11-01

    To prevent blood transfusion-acquired HIV infection with a decentralized approach to HIV screening of blood donors, using an instrument-free rapid test. Shaba province, Zaire (496,877 km2). The programme consisted of training health-care workers, distribution of a rapid HIV-antibody test (DuPont's HIVCHEK) for screening of all blood donations, and quality control of testing by a regional reference centre. Over a 2-year period, 11,940 rapid tests were distributed to 37 hospitals, covering 75% of all hospital beds outside the copper mine's health system in Shaba. Eighty-five per cent of the tests were used to screen blood donors (5.4% positive test rate) and 13% to test patients (39.7% positive test rate). At least 265 cases of HIV-positive blood donation were prevented, at an estimated cost of 137-279 ECU per case. Only 26% of initially positive specimens reached the central laboratory for supplemental testing, and sterile transfusion equipment and blood-grouping reagents were frequently unavailable. The lack of transport and communications and a deteriorating health system were major constraints. District hospitals in Africa are often long distances from major cities, difficult to reach for most of the year, and perform a small number of transfusions. In this context a classical centralized regional blood bank may not be a feasible option to ensure safe blood transfusions. However, safe blood transfusion can be achieved with a decentralized approach using a rapid test, provided that minimum standards of health-care services are available.

  20. Displaying Geographically-Based Domestic Statistics

    NASA Technical Reports Server (NTRS)

    Quann, J.; Dalton, J.; Banks, M.; Helfer, D.; Szczur, M.; Winkert, G.; Billingsley, J.; Borgstede, R.; Chen, J.; Chen, L.; hide

    1982-01-01

    Decision Information Display System (DIDS) is rapid-response information-retrieval and color-graphics display system. DIDS transforms tables of geographically-based domestic statistics (such as population or unemployment by county, energy usage by county, or air-quality figures) into high-resolution, color-coded maps on television display screen.

  1. The Infrared Automatic Mass Screening (IRAMS) System For Printed Circuit Board Fault Detection

    NASA Astrophysics Data System (ADS)

    Hugo, Perry W.

    1987-05-01

    Office of the Program Manager for TMDE (OPM TMDE) has initiated a program to develop techniques for evaluating the performance of printed circuit boards (PCB's) using infrared thermal imaging. It is OPM TMDE's expectation that the standard thermal profile (STP) will become the basis for the future rapid automatic detection and isolation of gross failure mechanisms on units under test (UUT's). To accomplish this OPM TMDE has purchased two Infrared Automatic Mass Screening ( I RAMS) systems which are scheduled for delivery in 1987. The IRAMS system combines a high resolution infrared thermal imager with a test bench and diagnostic computer hardware and software. Its purpose is to rapidly and automatically compare the thermal profiles of a UUT with the STP of that unit, recalled from memory, in order to detect thermally responsive failure mechanisms in PCB's. This paper will review the IRAMS performance requirements, outline the plan for implementing the two systems and report on progress to date.

  2. A multiplexed microfluidic toolbox for the rapid optimization of affinity-driven partition in aqueous two phase systems.

    PubMed

    Bras, Eduardo J S; Soares, Ruben R G; Azevedo, Ana M; Fernandes, Pedro; Arévalo-Rodríguez, Miguel; Chu, Virginia; Conde, João P; Aires-Barros, M Raquel

    2017-09-15

    Antibodies and other protein products such as interferons and cytokines are biopharmaceuticals of critical importance which, in order to be safely administered, have to be thoroughly purified in a cost effective and efficient manner. The use of aqueous two-phase extraction (ATPE) is a viable option for this purification, but these systems are difficult to model and optimization procedures require lengthy and expensive screening processes. Here, a methodology for the rapid screening of antibody extraction conditions using a microfluidic channel-based toolbox is presented. A first microfluidic structure allows a simple negative-pressure driven rapid screening of up to 8 extraction conditions simultaneously, using less than 20μL of each phase-forming solution per experiment, while a second microfluidic structure allows the integration of multi-step extraction protocols based on the results obtained with the first device. In this paper, this microfluidic toolbox was used to demonstrate the potential of LYTAG fusion proteins used as affinity tags to optimize the partitioning of antibodies in ATPE processes, where a maximum partition coefficient (K) of 9.2 in a PEG 3350/phosphate system was obtained for the antibody extraction in the presence of the LYTAG-Z dual ligand. This represents an increase of approx. 3.7 fold when compared with the same conditions without the affinity molecule (K=2.5). Overall, this miniaturized and versatile approach allowed the rapid optimization of molecule partition followed by a proof-of-concept demonstration of an integrated back extraction procedure, both of which are critical procedures towards obtaining high purity biopharmaceuticals using ATPE. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. An Escherichia coli Expression Assay and Screen for Human Immunodeficiency Virus Protease Variants with Decreased Susceptibility to Indinavir

    PubMed Central

    Melnick, Laurence; Yang, Shiow-Shong; Rossi, Rick; Zepp, Charlie; Heefner, Donald

    1998-01-01

    We have developed a recombinant Escherichia coli screening system for the rapid detection and identification of amino acid substitutions in the human immunodeficiency virus (HIV) protease associated with decreased susceptibility to the protease inhibitor indinavir (MK-639; Merck & Co.). The assay depends upon the correct processing of a segment of the HIV-1 HXB2 gag-pol polyprotein followed by detection of HIV reverse transcriptase activity by a highly sensitive, colorimetric enzyme-linked immunosorbent assay. The highly sensitive system detects the contributions of single substitutions such as I84V, L90M, and L63P. The combination of single substitutions further decreases the sensitivity to indinavir. We constructed a library of HIV protease variant genes containing dispersed mutations and, using the E. coli recombinant system, screened for mutants with decreased indinavir sensitivity. The discovered HIV protease variants contain amino acid substitutions commonly associated with indinavir resistance in clinical isolates, including the substitutions L90M, L63P, I64V, V82A, L24I, and I54T. One substitution, W6R, is also frequently found by the screen and has not been reported elsewhere. Of a total of 12,000 isolates that were screened, 12 protease variants with decreased sensitivity to indinavir were found. The L63P substitution, which is also associated with indinavir resistance, increases the stability of the isolated protease relative to that of the native HXB2 protease. The rapidity, sensitivity, and accuracy of this screen also make it useful for screening for novel inhibitors. We have found the approach described here to be useful for the detection of amino acid substitutions in HIV protease that have been associated with drug resistance as well as for the screening of novel compounds for inhibitory activity. PMID:9835523

  4. Development and validation of a brief trauma screening measure for children: The Child Trauma Screen.

    PubMed

    Lang, Jason M; Connell, Christian M

    2017-05-01

    Childhood exposure to trauma, including violence and abuse, is a major public health concern that has resulted in increased efforts to promote trauma-informed child-serving systems. Trauma screening is an important component of such trauma-informed systems, yet widespread use of trauma screening is rare in part due to the lack of brief, validated trauma screening measures for children. We describe development and validation of the Child Trauma Screen (CTS), a 10-item screening measure of trauma exposure and posttraumatic stress disorder (PTSD) symptoms for children consistent with the DSM-5 definition of PTSD. Study 1 describes measure development incorporating analysis to derive items based on existing measures from 1,065 children and caregivers together with stakeholder input to finalize item selection. Study 2 describes validation of the CTS with a clinical sample of 74 children and their caregivers. Results support the CTS as an empirically derived, reliable measure to screen children for trauma exposure and PTSD symptoms with strong convergent, divergent, and criterion validity. The CTS is a promising measure for rapidly and reliably screening children for trauma exposure and PTSD symptoms. Future research is needed to confirm validation and to examine feasibility and utility of its use across various child-serving systems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Effectiveness Analysis of a Part-Time Rapid Response System During Operation Versus Nonoperation.

    PubMed

    Kim, Youlim; Lee, Dong Seon; Min, Hyunju; Choi, Yun Young; Lee, Eun Young; Song, Inae; Park, Jong Sun; Cho, Young-Jae; Jo, You Hwan; Yoon, Ho Il; Lee, Jae Ho; Lee, Choon-Taek; Do, Sang Hwan; Lee, Yeon Joo

    2017-06-01

    To evaluate the effect of a part-time rapid response system on the occurrence rate of cardiopulmonary arrest by comparing the times of rapid response system operation versus nonoperation. Retrospective cohort study. A 1,360-bed tertiary care hospital. Adult patients admitted to the general ward were screened. Data were collected over 36 months from rapid response system implementation (October 2012 to September 2015) and more than 45 months before rapid response system implementation (January 2009 to September 2012). None. The rapid response system operates from 7 AM to 10 PM on weekdays and from 7 AM to 12 PM on Saturdays. Primary outcomes were the difference of cardiopulmonary arrest incidence between pre-rapid response system and post-rapid response system periods and whether the rapid response system operating time affects the cardiopulmonary arrest incidence. The overall cardiopulmonary arrest incidence (per 1,000 admissions) was 1.43. Although the number of admissions per month and case-mix index were increased (3,555.18 vs 4,564.72, p < 0.001; 1.09 vs 1.13, p = 0.001, respectively), the cardiopulmonary arrest incidence was significantly decreased after rapid response system (1.60 vs 1.23; p = 0.021), and mortality (%) was unchanged (1.38 vs 1.33; p = 0.322). After rapid response system implementation, the cardiopulmonary arrest incidence significantly decreased by 40% during rapid response system operating times (0.82 vs 0.49/1,000 admissions; p = 0.001) but remained similar during rapid response system nonoperating times (0.77 vs 0.73/1,000 admissions; p = 0.729). The implementation of a part-time rapid response system reduced the cardiopulmonary arrest incidence based on the reduction of cardiopulmonary arrest during rapid response system operating times. Further analysis of the cost effectiveness of part-time rapid response system is needed.

  6. Using Microelectrode Arrays for Neurotoxicity Screening

    EPA Science Inventory

    Chemicals can disrupt nervous system electrical activity, rapidly causing toxicity prior to, or in the absence of, biochemical or morphological changes. However, high-throughput, functional approaches to detect chemical induced changes in electrical excitability are lacking. Micr...

  7. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    PubMed

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  8. Targeting the-Dopaminergic Nervous System: Altering Behavior in Larval Zebrafish

    EPA Science Inventory

    Zebrafish (Dania rerio) are becoming an important model system in studying the effects of environmental chemicals on behavior. In order to develop a rapid in vivo screen to prioritize toxic chemicals, we have begun assessing the acute locomotor effects of drugs that act on the do...

  9. Rapid Screening of Bovine Milk Oligosaccharides in a Whey Permeate Product and Domestic Animal Milks by Accurate Mass Database and Tandem Mass Spectral Library.

    PubMed

    Lee, Hyeyoung; Cuthbertson, Daniel J; Otter, Don E; Barile, Daniela

    2016-08-17

    A bovine milk oligosaccharide (BMO) library, prepared from cow colostrum, with 34 structures was generated and used to rapidly screen oligosaccharides in domestic animal milks and a whey permeate powder. The novel library was entered into a custom Personal Compound Database and Library (PCDL) and included accurate mass, retention time, and tandem mass spectra. Oligosaccharides in minute-sized samples were separated using nanoliquid chromatography (nanoLC) coupled to a high resolution and sensitive quadrupole-Time of Flight (Q-ToF) MS system. Using the PCDL, 18 oligosaccharides were found in a BMO-enriched product obtained from whey permeate processing. The usefulness of the analytical system and BMO library was further validated using milks from domestic sheep and buffaloes. Through BMO PCDL searching, 15 and 13 oligosaccharides in the BMO library were assigned in sheep and buffalo milks, respectively, thus demonstrating significant overlap between oligosaccharides in bovine (cow and buffalo) and ovine (sheep) milks. This method was shown to be an efficient, reliable, and rapid tool to identify oligosaccharide structures using automated spectral matching.

  10. Rapid Screening of Bovine Milk Oligosaccharides in a Whey Permeate Product and Domestic Animal Milks by Accurate Mass Database and Tandem Mass Spectral Library

    PubMed Central

    Lee, Hyeyoung; Cuthbertson, Daniel J.; Otter, Don E.; Barile, Daniela

    2018-01-01

    A bovine milk oligosaccharide (BMO) library, prepared from cow colostrum, with 34 structures was generated and used to rapidly screen oligosaccharides in domestic animal milks and a whey permeate powder. The novel library was entered into a custom Personal Compound Database and Library (PCDL) and included accurate mass, retention time, and tandem mass spectra. Oligosaccharides in minute-sized samples were separated using nanoliquid chromatography (nanoLC) coupled to a high resolution and sensitive quadrupole-Time of Flight (Q-ToF) MS system. Using the PCDL, 18 oligosaccharides were found in a BMO-enriched product obtained from whey permeate processing. The usefulness of the analytical system and BMO library was further validated using milks from domestic sheep and buffaloes. Through BMO PCDL searching, 15 and 13 oligosaccharides in the BMO library were assigned in sheep and buffalo milks, respectively, thus demonstrating significant overlap between oligosaccharides in bovine (cow and buffalo) and ovine (sheep) milks. This method was shown to be an efficient, reliable, and rapid tool to identify oligosaccharide structures using automated spectral matching. PMID:27428379

  11. Cross-species extrapolation of toxicity information using the ...

    EPA Pesticide Factsheets

    In the United States, the Endocrine Disruptor Screening Program (EDSP) was established to identify chemicals that may lead to adverse effects via perturbation of the endocrine system (i.e., estrogen, androgen, and thyroid hormone systems). In the mid-1990s the EDSP adopted a two tiered approach for screening chemicals that applied standardized in vitro and in vivo toxicity tests. The Tier 1 screening assays were designed to identify substances that have the potential of interacting with the endocrine system and Tier 2 testing was developed to identify adverse effects caused by the chemical, with documentation of dose-response relationships. While this tiered approach was effective in identifying possible endocrine disrupting chemicals, the cost and time to screen a single chemical was significant. Therefore, in 2012 the EDSP proposed a transition to make greater use of computational approaches (in silico) and high-throughput screening (HTS; in vitro) assays to more rapidly and cost-efficiently screen chemicals for endocrine activity. This transition from resource intensive, primarily in vivo, screening methods to more pathway-based approaches aligns with the simultaneously occurring transformation in toxicity testing termed “Toxicity Testing in the 21st Century” which shifts the focus to the disturbance of the biological pathway predictive of the observable toxic effects. An example of such screening tools include the US Environmental Protection Agency’s

  12. Advances in Materials and System Technology for Portable Fuel Cells

    NASA Technical Reports Server (NTRS)

    Narayanan, Sekharipuram R.

    2007-01-01

    This viewgraph presentation describes the materials and systems engineering used for portable fuel cells. The contents include: 1) Portable Power; 2) Technology Solution; 3) Portable Hydrogen Systems; 4) Direct Methanol Fuel Cell; 5) Direct Methanol Fuel Cell System Concept; 6) Overview of DMFC R&D at JPL; 7) 300-Watt Portable Fuel Cell for Army Applications; 8) DMFC units from Smart Fuel Cell Inc, Germany; 9) DMFC Status and Prospects; 10) Challenges; 11) Rapid Screening of Well-Controlled Catalyst Compositions; 12) Screening of Ni-Zr-Pt-Ru alloys; 13) Issues with New Membranes; 14) Membranes With Reduced Methanol Crossover; 15) Stacks; 16) Hybrid DMFC System; 17) Small Compact Systems; 18) Durability; and 19) Stack and System Parameters for Various Applications.

  13. The TV Turtle: A LOGO Graphics System for Raster Displays. AI Memo 361.

    ERIC Educational Resources Information Center

    Lieberman, Henry

    This discussion of the advantages and limitations of raster graphics systems points out that until recently, most computer graphics systems have been oriented toward the display of line drawings, continually refreshing the screen from a display list of vectors. Developments such as plasma panel displays and rapidly declining memory prices have now…

  14. Comparison of Three Biochemical Tests for Rapid Detection of Extended-Spectrum-β-Lactamase-Producing Enterobacteriaceae.

    PubMed

    Poirel, Laurent; Fernández, Javier; Nordmann, Patrice

    2016-02-01

    Enterobacterial isolates producing clavulanic-inhibited extended-spectrum β-lactamases (ESBLs) are increasingly spreading in the community and are often responsible for nosocomial infections. Rapid biochemical tests have been developed recently for their detection. Three tests, namely, the Rapid ESBL NDP test, the β-Lacta test, and the Rapid ESBL Screen, have been evaluated with a collection of 108 well-characterized strains, including wild-type strains, strains producing ESBLs, overexpressed cephalosporinases, and carbapenemases. The ESBL NDP test and the Rapid ESBL Screen (a copy of the ESBL NDP test) are aimed at detecting ESBL producers, while the β-Lacta test is aimed at detecting not only ESBL producers but also cephalosporinase and carbapenemase producers. The sensitivity and specificity for detecting ESBL producers (n = 60) were 95% and 100% for the Rapid ESBL NDP test, 80% and 87% (after 30 min) and 92% and 83% (after 2 h) for the Rapid ESBL Screen, and 88% and 71% for the β-Lacta test, respectively. Varied and time-consuming detection (up to 2 h) of ESBLs by the Rapid ESBL Screen and concomitant and varied detection of producers of AmpC and several types of carbapenemases correspond to significant shortcomings of using the Rapid Screen ESBL and β-Lacta tests, respectively. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  15. Screening and identification of novel biologically active natural compounds.

    PubMed

    Newman, David

    2017-01-01

    With the advent of very rapid and cheap genome analyses and the linkage of these plus microbial metabolomics to potential compound structures came the realization that there was an immense sea of novel agents to be mined and tested. In addition, it is now recognized that there is significant microbial involvement in many natural products isolated from "nominally non-microbial sources". This short review covers the current screening methods that have evolved and one might even be tempted to say "devolved" in light of the realization that target-based screens had problems when the products entered clinical testing, with off-target effects being the major ones. Modern systems include, but are not limited to, screening in cell lines utilizing very modern techniques (a high content screen) that are designed to show interactions within cells when treated with an "agent". The underlying principle(s) used in such systems dated back to unpublished attempts in the very early 1980s by the pharmaceutical industry to show toxic interactions within animal cells by using automated light microscopy. Though somewhat successful, the technology was not adequate for any significant commercialization. Somewhat later, mammalian cell lines that were "genetically modified" to alter signal transduction cascades, either up or down, and frequently linked to luciferase readouts, were then employed in a 96-well format. In the case of microbes, specific resistance parameters were induced in isogenic cell lines from approximately the mid-1970s. In the latter two cases, comparisons against parent and sibling cell lines were used in order that a rapid determination of potential natural product "hits" could be made. Obviously, all of these assay systems could also be, and were, used for synthetic molecules. These methods and their results have led to a change in what the term "screening for bioactivity" means. In practice, versions of phenotypic screening are returning, but in a dramatically different scientific environment from the 1970s, as I hope to demonstrate in the short article that follows.

  16. Legal and Ethical Considerations in Allowing Parental Exemptions From Newborn Critical Congenital Heart Disease (CCHD) Screening.

    PubMed

    Hom, Lisa A; Silber, Tomas J; Ennis-Durstine, Kathleen; Hilliard, Mary Anne; Martin, Gerard R

    2016-01-01

    Critical congenital heart disease (CCHD) screening is rapidly becoming the standard of care in the United States after being added to the Recommended Uniform Screening Panel (RUSP) in 2011. Newborn screens typically do not require affirmative parental consent. In fact, most states allow parents to exempt their baby from receiving the required screen on the basis of religious or personally held beliefs. There are many ethical considerations implicated with allowing parents to exempt their child from newborn screening for CCHD. Considerations include the treatment of religious exemptions in our current legal system, as well as medical and ethical principles in relation to the rights of infants. Although there are significant benefits to screening newborns for CCHD, when a parent refuses for religious or personal beliefs, in the case of CCHD screening, the parental decision should stand.

  17. Changing the Scale and Efficiency of Chemical Warfare Countermeasure Discovery Using the Zebrafish

    PubMed Central

    Peterson, Randall T.; MacRae, Calum A.

    2013-01-01

    As the scope of potential chemical warfare agents grows rapidly and as the diversity of potential threat scenarios expands with non-state actors, so a need for innovative approaches to countermeasure development has emerged. In the last few years, the utility of the zebrafish as a model organism that is amenable to high-throughput screening has become apparent and this system has been applied to the unbiased discovery of chemical warfare countermeasures. This review summarizes the in vivo screening approach that has been pioneered in the countermeasure discovery arena, and highlights the successes to date as well as the potential challenges in moving the field forward. Importantly, the establishment of a zebrafish platform for countermeasure discovery would offer a rapid response system for the development of antidotes to the continuous stream of new potential chemical warfare agents. PMID:24273586

  18. Continuous flow immobilized enzyme reactor-tandem mass spectrometry for screening of AChE inhibitors in complex mixtures.

    PubMed

    Forsberg, Erica M; Green, James R A; Brennan, John D

    2011-07-01

    A method is described for identifying bioactive compounds in complex mixtures based on the use of capillary-scale monolithic enzyme-reactor columns for rapid screening of enzyme activity. A two-channel nanoLC system was used to continuously infuse substrate coupled with automated injections of substrate/small molecule mixtures, optionally containing the chromogenic Ellman reagent, through sol-gel derived acetylcholinesterase (AChE) doped monolithic columns. This is the first report of AChE encapsulated in monolithic silica for use as an immobilized enzyme reactor (IMER), and the first use of such IMERs for mixture screening. AChE IMER columns were optimized to allow rapid functional screening of compound mixtures based on changes in the product absorbance or the ratio of mass spectrometric peaks for product and substrate ions in the eluent. The assay had robust performance and produced a Z' factor of 0.77 in the presence of 2% (v/v) DMSO. A series of 52 mixtures consisting of 1040 compounds from the Canadian Compound Collection of bioactives was screened and two known inhibitors, physostigmine and 9-aminoacridine, were identified from active mixtures by manual deconvolution. The activity of the compounds was confirmed using the enzyme reactor format, which allowed determination of both IC(50) and K(I) values. Screening results were found to correlate well with a recently published fluorescence-based microarray screening assay for AChE inhibitors.

  19. Screening Fusion Tags for Improved Recombinant Protein Expression in E. coli with the Expresso® Solubility and Expression Screening System.

    PubMed

    Steinmetz, Eric J; Auldridge, Michele E

    2017-11-01

    The simplicity, speed, and low cost of bacterial culture make E. coli the system of choice for most initial trials of recombinant protein expression. However, many heterologous proteins are either poorly expressed in bacteria, or are produced as incorrectly folded, insoluble aggregates that lack the activity of the native protein. In many cases, fusion to a partner protein can allow for improved expression and/or solubility of a difficult target protein. Although several different fusion partners have gained favor, none are universally effective, and identifying the one that best improves soluble expression of a given target protein is an empirical process. This unit presents a strategy for parallel screening of fusion partners for enhanced expression or solubility. The Expresso® Solubility and Expression Screening System includes a panel of seven distinct fusion partners and utilizes an extremely simple cloning strategy to enable rapid screening and identification of the most effective fusion partner. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  20. The performance of spatially offset Raman spectroscopy for liquid explosive detection

    NASA Astrophysics Data System (ADS)

    Loeffen, Paul W.; Maskall, Guy; Bonthron, Stuart; Bloomfield, Matthew; Tombling, Craig; Matousek, Pavel

    2016-10-01

    Aviation security requirements adopted in 2014 require liquids to be screened at most airports throughout Europe, North America and Australia. Cobalt's unique Spatially Offset Raman Spectroscopy (SORS™) technology has proven extremely effective at screening liquids, aerosols and gels (LAGS) with extremely low false alarm rates. SORS is compatible with a wide range of containers, including coloured, opaque or clear plastics, glass and paper, as well as duty-free bottles in STEBs (secure tamper-evident bags). Our award-winning Insight range has been specially developed for table-top screening at security checkpoints. Insight systems use our patented SORS technology for rapid and accurate chemical analysis of substances in unopened non-metallic containers. Insight100M™ and the latest member of the range - Insight200M™ - also screen metallic containers. Our unique systems screen liquids, aerosols and gels with the highest detection capability and lowest false alarm rates of any ECAC-approved scanner, with several hundred units already in use at airports including eight of the top ten European hubs. This paper presents an analysis of real performance data for these systems.

  1. Towards the comprehensive, rapid, and accurate prediction of the favorable tautomeric states of drug-like molecules in aqueous solution

    NASA Astrophysics Data System (ADS)

    Greenwood, Jeremy R.; Calkins, David; Sullivan, Arron P.; Shelley, John C.

    2010-06-01

    Generating the appropriate protonation states of drug-like molecules in solution is important for success in both ligand- and structure-based virtual screening. Screening collections of millions of compounds requires a method for determining tautomers and their energies that is sufficiently rapid, accurate, and comprehensive. To maximise enrichment, the lowest energy tautomers must be determined from heterogeneous input, without over-enumerating unfavourable states. While computationally expensive, the density functional theory (DFT) method M06-2X/aug-cc-pVTZ(-f) [PB-SCRF] provides accurate energies for enumerated model tautomeric systems. The empirical Hammett-Taft methodology can very rapidly extrapolate substituent effects from model systems to drug-like molecules via the relationship between pKT and pKa. Combining the two complementary approaches transforms the tautomer problem from a scientific challenge to one of engineering scale-up, and avoids issues that arise due to the very limited number of measured pKT values, especially for the complicated heterocycles often favoured by medicinal chemists for their novelty and versatility. Several hundreds of pre-calculated tautomer energies and substituent pKa effects are tabulated in databases for use in structural adjustment by the program Epik, which treats tautomers as a subset of the larger problem of the protonation states in aqueous ensembles and their energy penalties. Accuracy and coverage is continually improved and expanded by parameterizing new systems of interest using DFT and experimental data. Recommendations are made for how to best incorporate tautomers in molecular design and virtual screening workflows.

  2. Rapid identification of microorganisms for biodegradation of alkylphenols and alkylphenol ethercarboxylates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hemming, B.; Williams, J.B.

    1995-12-31

    Alkylphenols, especially nonylphenol and octylphenol, are used in a wide variety of applications. These compounds, and alkylphenol ethercarboxylates, are also believed to be formed during the biodegradation of alkylphenol ethoxylates in activated sludge wastewater treatment systems. Microbe Inotech Laboratories has developed a rapid assay to identify the microorganisms present in activated sludge wastewater treatment systems (GC-FAME) and a screening assay to measure the biodegradation of compounds. These assays were used to show that alkylphenols and their corresponding ethercarboxylates were degraded aerobically even when these compounds were the sole carbon source.

  3. Ultrafast STR Separations on Short-Channel Microfluidic Systems for Forensic Screening and Genotyping.

    PubMed

    Aboud, Maurice J; Gassmann, Marcus; McCord, Bruce

    2015-09-01

    There are situations in which it is important to quickly and positively identify an individual. Examples include suspects detained in the neighborhood of a bombing or terrorist incident, individuals detained attempting to enter or leave the country, and victims of mass disasters. Systems utilized for these purposes must be fast, portable, and easy to maintain. DNA typing methods provide the best biometric information yielding identity, kinship, and geographical origin, but they are not portable and rapid. This study details the development of a portable short-channel microfluidic device based on a modified Agilent 2100 bioanalyzer for applications in forensic genomics. The system utilizes a denaturing polymer matrix with dual-channel laser-induced fluorescence and is capable of producing a genotype in 80 sec. The device was tested for precision and resolution using an allelic ladder created from 6 short tandem repeat (STR) loci and a sex marker (amelogenin). The results demonstrated a precision of 0.09-0.21 bp over the entire size range and resolution values from 2.5 to 4.1 bp. Overall, the results demonstrate the chip provides a portable, rapid, and precise method for screening amplified short tandem repeats and human identification screening. © 2015 American Academy of Forensic Sciences.

  4. IMMORTALIZED MICROGLIAL CELLS AS A MODEL SYSTEM FOR OXIDATIVE STRESS: PESTICIDE-INDUCED GENOMIC GHANGES.

    EPA Science Inventory

    In risk assessment there is a need to accelerate toxicological evaluation of vast numbers of chemicals. New programs focus on identifying common modes of action and on model systems for rapid screening. In this study we address both these issues. Oxidative stress is a good can...

  5. ASSESSMENT OF CHEMICAL EFFECTS ON NEURONAL DIFFERENTIATION USING THE ARRAYSCAN HIGH CONTENT SCREENING SYSTEM

    EPA Science Inventory

    The development of alternative methods for toxicity testing is driven by the need for scientifically valid data that can be obtained in a rapid and cost-efficient manner. In vitro systems provide a model in which chemical effects on cellular events can be examined using technique...

  6. Advanced Millimeter-Wave Imaging Enhances Security Screening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheen, David M.; Bernacki, Bruce E.; McMakin, Douglas L.

    2012-01-12

    Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.

  7. Solid-phase microextraction of organophosphate pesticides in source waters for drinking water treatment facilities.

    PubMed

    Flynt, Elizabeth; Dupuy, Aubry; Kennedy, Charles; Bennett, Shanda

    2006-09-01

    The rapid detection of contaminants in our nation's drinking water has become a top homeland security priority in this time of increased national vigilance. Real-time monitoring of drinking water for deliberate or accidental contamination is key to national security. One method that can be employed for the rapid screening of pollutants in water is solid-phase microextraction (SPME). SPME is a rapid, sensitive, solvent-free system that can be used to screen for contaminants that have been accidentally or intentionally introduced into a water system. A method using SPME has been developed and optimized for the detection of seven organophosphate pesticides in drinking water treatment facility source waters. The method is tested in source waters for drinking water treatment facilities in Mississippi and Alabama. Water is collected from a deepwater well at Stennis Space Center (SSC), MS, the drinking water source for SSC, and from the Converse Reservoir, the main drinking water supply for Mobile, AL. Also tested are samples of water collected from the Mobile Alabama Water and Sewer System drinking water treatment plant prior to chlorination. The method limits of detection for the seven organophosphates were comparable to those described in several Environmental Protection Agency standard methods. They range from 0.25 to 0.94 microg/L.

  8. Zebrafish Development: High-throughput Test Systems to Assess Developmental Toxicity

    EPA Science Inventory

    Abstract Because of its developmental concordance, ease of handling and rapid development, the small teleost, zebrafish (Danio rerio), is frequently promoted as a vertebrate model for medium-throughput developmental screens. This present chapter discusses zebrafish as an altern...

  9. "RAPID" team triage: one hospital's approach to patient-centered team triage.

    PubMed

    Shea, Sheila Sanning; Hoyt, K Sue

    2012-01-01

    Patients who present to the emergency department want definitive care by a health care provider who can perform an initial assessment, initiate treatment, and implement a disposition plan. The traditional "nurse triage" model often creates barriers to the process of rapidly evaluating patients. Therefore, innovative strategies must be explored to improve the time of patient arrival to the time seen by a qualified provider in order to complete a thorough medical screening examination. One such approach is a rapid team triage system that provides a patient-centered process. This article describes the implementation of a rapid team triage model in an urban community hospital.

  10. Assessing patients' attitudes to opt-out HIV rapid screening in community dental clinics: a cross-sectional Canadian experience.

    PubMed

    Brondani, Mario; Chang, Steve; Donnelly, Leeann

    2016-05-10

    As a public health initiative, provided-initiated HIV screening test in dental settings has long been available in the U.S.; it was only in 2011 that such setting was used in Canada. The objective of this paper was to assess patients' response to, and attitudes towards, an opt-out rapid HIV screening test in a dental setting in Vancouver, Canada. A cross-sectional evaluation design using a self-complete survey questionnaire on self-perceived values and benefits of an opt-out rapid HIV screening was employed. An anonymous 10-item questionnaire was developed to explore reasons for accepting or declining the HIV rapid screening test, and barriers and facilitators for the HIV screening in dental settings. Eligible participants were male and female older than 19 years attending community dental clinics and who were offered the HIV screening test between June 2010 and February 2015. From the 1552 age-eligible patients, 519 completed the survey and 155 (10 %) accepted the HIV screening due to its convenience, and/or free cost, and/or instant results. From the 458 respondents who did not accept the screening, 362 (79 %) were between the ages of 25 and 45 years; 246 (53.7 %) had identifiable risk factors for contracting HIV; and 189 (41.3 %) reported having been tested within the last 3 months. Those tested in less than 3 months had 3.5 times higher odds to decline the HIV screening compared to those who have been tested between 3 months and 1 year. Convenience, cost-free and readily available results are factors influencing rapid HIV screening uptake. Although dental settings remain an alternative venue for HIV screening from the patients' perspectives, dental hygiene settings might offer a better option.

  11. Case finding advantage of HIV rapid tests in community settings: men who have sex with men in 12 programme areas in China, 2011.

    PubMed

    Zhang, Dapeng; Qi, Jinlei; Fu, Xiaojing; Meng, Sining; Li, Chengmei; Sun, Jiangping

    2015-05-01

    We sought to describe the advantage of rapid tests over ELISA tests in community-based screening for HIV among men who have sex with men (MSM) in urban areas of China. Data of 31,406 screening tests conducted over six months in 2011 among MSM across 12 areas were analyzed to compare the differences between those receiving rapid testing and ELISA. Rapid tests accounted for 45.8% of these screening tests. The rate of being screened positive was 7.2% among rapid tests and 5.3% for ELISA tests (χ(2 )= 49.161, p < 0.001). This advantage of rapid test in HIV case finding persisted even when socio-demographic, behavioural, screening recruitment channel and city were controlled for in logistic regression (exp[beta] = 1.42, p < 0.001, 95% CI = 1.27,1.59). MSM who received rapid tests, compared with those tested by ELISA, were less likely to use condoms during last anal sex (50.8% vs. 72.3%, χ(2 )= 1706.146, p < 0.001), more likely to have multiple sex partners (55.7% vs. 49.5%, χ(2 )= 238.188, p < 0.001) and less likely to have previously undergone HIV testing (38.8% vs. 54.7%, χ(2 )= 798.476, p < 0.001). These results demonstrate the robustness of the advantage of rapid tests over traditional ELISA tests in screening for MSM with HIV infection in cooperation with community-based organizations in urban settings in China. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. The costs of accessible quality assured syphilis diagnostics: informing quality systems for rapid syphilis tests in a Tanzanian setting.

    PubMed

    Sweeney, Sedona; Mosha, Jacklin F; Terris-Prestholt, Fern; Sollis, Kimberly A; Kelly, Helen; Changalucha, John; Peeling, Rosanna W

    2014-08-01

    To determine the costs of Rapid Syphilis Test (RSTs) as compared with rapid plasma reagin (RPR) when implemented in a Tanzanian setting, and to determine the relative impact of a quality assurance (QA) system on the cost of RST implementation. The incremental costs for RPR and RST screening programmes in existing antenatal care settings in Geita District, Tanzania were collected for 9 months in subsequent years from nine health facilities that varied in size, remoteness and scope of antenatal services. The costs per woman tested and treated were estimated for each facility. A sensitivity analysis was constructed to determine the impact of parameter and model uncertainty. In surveyed facilities, a total of 6362 women were tested with RSTs compared with 224 tested with RPR. The range of unit costs was $1.76-$3.13 per woman screened and $12.88-$32.67 per woman treated. Unit costs for the QA system came to $0.51 per woman tested, of which 50% were attributed to salaries and transport for project personnel. Our results suggest that rapid syphilis diagnostics are very inexpensive in this setting and can overcome some critical barriers to ensuring universal access to syphilis testing and treatment. The additional costs for implementation of a quality system were found to be relatively small, and could be reduced through alterations to the programme design. Given the potential for a quality system to improve quality of diagnosis and care, we recommend that QA activities be incorporated into RST roll-out. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2013; all rights reserved.

  13. Effectiveness of rapid prescreening and 10% rescreening in liquid-based Papanicolaou testing.

    PubMed

    Currens, Heather S; Nejkauf, Katharine; Wagner, Lynn; Raab, Stephen S

    2012-01-01

    Although rapid prescreening (RPS) has been shown to be an effective quality control procedure for detecting false-negative conventional Papanicolaou (Pap) tests, RPS has not been widely implemented in the United States. In our laboratory, cytotechnologists performed RPS in 3,567 liquid-based Pap tests: 1,911 SurePath (BD Diagnostics-TriPath, Burlington, NC) preparations that were manually screened and 1,656 ThinPrep Pap tests (Hologic, Bedford, MA) that were imaged using the ThinPrep Imaging System (Hologic). We compared the sensitivity of RPS, 10% rescreening (R-10%), and routine screening (RS). In contrast with previously published findings, we found that RS + RPS did not improve screening sensitivity compared with RS + R-10%. These results support the following hypotheses: (1) Higher baseline RS sensitivity as a result of Pap test diagnoses standardization implemented for quality improvement purposes decreases the performance impact of RPS. (2) R-10% and RPS quality assurance methods detect diagnostic failures caused by different types of cognitive errors.

  14. A screening approach using zebrafish for the detection and characterization of developmental neurotoxicity.

    EPA Science Inventory

    Thousands of chemicals have little or no data to support developmental neurotoxicity risk assessments. Current developmental neurotoxicity guideline studies mandating mammalian model systems are expensive and time consuming. Therefore a rapid, cost-effective method to assess de...

  15. Newborn screening policy in the United Kingdom & the United States: two different communities of practice.

    PubMed

    Patch, Christine

    2006-01-01

    Newborn screening is a rapidly developing area driven by both technological advances and public pressure. If they are not yet, all nurses working with mothers and children will soon be involved with implementing newborn-screening programs, and it is therefore important that they appreciate both the benefits and potential harms of such programs. In the United Kingdom, policy regarding the implementation of newborn-screening programs is developed at national level, and consideration of the introduction of new tests is subject to a formalized evaluation framework. In the United States, by contrast, each state develops its own screening program. Knowledge of developments in newborn screening in different countries that have diverse types of healthcare systems helps to inform nurses about the totality of healthcare for newborns, and assists them in becoming more knowledgeable about how international standards differ from those in the United States.

  16. Fishing anti(lymph)angiogenic drugs with zebrafish.

    PubMed

    García-Caballero, Melissa; Quesada, Ana R; Medina, Miguel A; Marí-Beffa, Manuel

    2018-02-01

    Zebrafish, an amenable small teleost fish with a complex mammal-like circulatory system, is being increasingly used for drug screening and toxicity studies. It combines the biological complexity of in vivo models with a higher-throughput screening capability compared with other available animal models. Externally growing, transparent embryos, displaying well-defined blood and lymphatic vessels, allow the inexpensive, rapid, and automatable evaluation of drug candidates that are able to inhibit neovascularisation. Here, we briefly review zebrafish as a model for the screening of anti(lymph)angiogenic drugs, with emphasis on the advantages and limitations of the different zebrafish-based in vivo assays. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. A Decision-Tree Approach to Cost Comparison of Newborn Screening Strategies for Cystic Fibrosis

    PubMed Central

    Wells, Janelle; Rosenberg, Marjorie; Hoffman, Gary; Anstead, Michael

    2012-01-01

    OBJECTIVE: Because cystic fibrosis can be difficult to diagnose and treat early, newborn screening programs have rapidly developed nationwide but methods vary widely. We therefore investigated the costs and consequences or specific outcomes of the 2 most commonly used methods. METHODS: With available data on screening and follow-up, we used a simulation approach with decision trees to compare immunoreactive trypsinogen (IRT) screening followed by a second IRT test against an IRT/DNA analysis. By using a Monte Carlo simulation program, variation in the model parameters for counts at various nodes of the decision trees, as well as for costs, are included and applied to fictional cohorts of 100 000 newborns. The outcome measures included the numbers of newborns given a diagnosis of cystic fibrosis and costs of screening strategy at each branch and cost per newborn. RESULTS: Simulations revealed a substantial number of potential missed diagnoses for the IRT/IRT system versus IRT/DNA. Although the IRT/IRT strategy with commonly used cutoff values offers an average overall cost savings of $2.30 per newborn, a breakdown of costs by societal segments demonstrated higher out-of-pocket costs for families. Two potential system failures causing delayed diagnoses were identified relating to the screening protocols and the follow-up system. CONCLUSIONS: The IRT/IRT screening algorithm reduces the costs to laboratories and insurance companies but has more system failures. IRT/DNA offers other advantages, including fewer delayed diagnoses and lower out-of-pocket costs to families. PMID:22291119

  18. In Vitro Toxicity Screening Technique for Volatile Substances Using Flow-Through System

    EPA Science Inventory

    In 2007 the National Research Council envisioned the need for inexpensive, rapid, cell based toxicity testing methods relevant to human health. Recent advances in robotics, automation, and miniaturization have been used to address these problems. However, one challenge is that ma...

  19. In Vitro Toxicity Screening Technique for Volatile Substances Using Flow-Through System##

    EPA Science Inventory

    In 2007 the National Research Council envisioned the need for inexpensive, rapid, cell based toxicity testing methods relevant to human health. Recent advances in robotics, automation, and miniaturization have been used to address this challenge. However, one drawback to currentl...

  20. Winthrop-University Hospital Infectious Disease Division's swine influenza (H1N1) pneumonia diagnostic weighted point score system for hospitalized adults with influenza-like illnesses (ILIs) and negative rapid influenza diagnostic tests (RIDTs).

    PubMed

    Cunha, Burke A; Syed, Uzma; Stroll, Stephanie; Mickail, Nardeen; Laguerre, Marianne

    2009-01-01

    In spring 2009, a novel strain of influenza A originating in Veracruz, Mexico, quickly spread to the United States and throughout the world. This influenza A virus was the product of gene reassortment of 4 different genetic elements: human influenza, swine influenza, avian influenza, and Eurasian swine influenza. In the United States, New York was the epicenter of the swine influenza (H1N1) pandemic. Hospital emergency departments (EDs) were inundated with patients with influenza-like illnesses (ILIs) requesting screening for H1N1. Our ED screening, as well as many others, used a rapid screening test for influenza A (QuickVue A/B) because H1N1 was a variant of influenza A. The definitive laboratory test i.e., RT-PCR for H1N1 was developed by the Centers for Disease Control (Atlanta, GA) and subsequently distributed to health departments. Because of the extraordinary volume of test requests, health authorities restricted reverse transcription polymerase chain reaction (RT-PCR) testing. Hence most EDs, including our own, were dependent on rapid influenza diagnostic tests (RIDTs) for swine influenza. A positive rapid influenza A test was usually predictive of RT-PCR H1N1 positivity, but the rapid influenza A screening test (QuickVue A/B) was associated with 30% false negatives. The inability to rely on RIDTs for H1N1 diagnosis resulted in underdiagnosing H1N1. Confronted with adults admitted with ILIs, negative RIDTs, and restricted RT-PCR testing, there was a critical need to develop clinical criteria to diagnose probable swine influenza H1N1 pneumonia. During the pandemic, the Infectious Disease Division at Winthrop-University Hospital developed clinical criteria for adult admitted patients with ILIs and negative RIDTs. Similar to the one developed for the clinical diagnosis of legionnaire's disease. The Winthrop-University Hospital Infectious Disease Division's diagnostic weighted point score system for swine influenza H1N1 pneumonia is based on key clinical and laboratory features. During the "herald" wave of the swine influenza H1N1 pandemic, the diagnostic weighted point score system accurately identified probable swine influenza H1N1 pneumonia and accurately differentiated swine influenza H1N1 pneumonia from ILIs and other viral and bacterial community-acquired pneumonias. In hospitalized adults with ILIs and negative RIDTs, the diagnostic weighted diagnostic point score system, may be used to make a presumptive clinical diagnosis of swine influenza H1N1 pneumonia.

  1. Remote sensing of multiple vital signs using a CMOS camera-equipped infrared thermography system and its clinical application in rapidly screening patients with suspected infectious diseases.

    PubMed

    Sun, Guanghao; Nakayama, Yosuke; Dagdanpurev, Sumiyakhand; Abe, Shigeto; Nishimura, Hidekazu; Kirimoto, Tetsuo; Matsui, Takemi

    2017-02-01

    Infrared thermography (IRT) is used to screen febrile passengers at international airports, but it suffers from low sensitivity. This study explored the application of a combined visible and thermal image processing approach that uses a CMOS camera equipped with IRT to remotely sense multiple vital signs and screen patients with suspected infectious diseases. An IRT system that produced visible and thermal images was used for image acquisition. The subjects' respiration rates were measured by monitoring temperature changes around the nasal areas on thermal images; facial skin temperatures were measured simultaneously. Facial blood circulation causes tiny color changes in visible facial images that enable the determination of the heart rate. A logistic regression discriminant function predicted the likelihood of infection within 10s, based on the measured vital signs. Sixteen patients with an influenza-like illness and 22 control subjects participated in a clinical test at a clinic in Fukushima, Japan. The vital-sign-based IRT screening system had a sensitivity of 87.5% and a negative predictive value of 91.7%; these values are higher than those of conventional fever-based screening approaches. Multiple vital-sign-based screening efficiently detected patients with suspected infectious diseases. It offers a promising alternative to conventional fever-based screening. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. Rapid biochemical screening for Salmonella, Shigella, Yersinia, and Aeromonas isolates from stool specimens.

    PubMed Central

    De Ryck, R; Struelens, M J; Serruys, E

    1994-01-01

    Four screens for the rapid (4 to 6 h) biochemical detection of pathogens from enteric isolation media are described. The Salmonella screen consisted of Kligler iron agar (KIA), motility-indole-urea-tryptophan-deamination semisolid medium (MIU-TDA), and the o-nitrophenyl-beta-D-galactopyranoside (ONPG) test; the Shigella screen consisted of KIA, MIU-TDA, the ONPG test, and the lysine decarboxylation-indole test; the Yersinia screen consisted of a rhamnose broth; the Aeromonas screen consisted of a xylose agar plate. When tested on 2,102 fresh isolates and 71 stock strains, the screens correctly detected 212 enteric pathogens (sensitivity, 100%), with a specificity of 98.1%. PMID:8077408

  3. Affordable proteomics: the two-hybrid systems.

    PubMed

    Gillespie, Marc

    2003-06-01

    Numerous proteomic methodologies exist, but most require a heavy investment in expertise and technology. This puts these approaches out of reach for many laboratories and small companies, rarely allowing proteomics to be used as a pilot approach for biomarker or target identification. Two proteomic approaches, 2D gel electrophoresis and the two-hybrid systems, are currently available to most researchers. The two-hybrid systems, though accommodating to large-scale experiments, were originally designed as practical screens, that by comparison to current proteomics tools were small-scale, affordable and technically feasible. The screens rapidly generated data, identifying protein interactions that were previously uncharacterized. The foundation for a two-hybrid proteomic investigation can be purchased as separate kits from a number of companies. The true power of the technique lies not in its affordability, but rather in its portability. The two-hybrid system puts proteomics back into laboratories where the output of the screens can be evaluated by researchers with experience in the particular fields of basic research, cancer biology, toxicology or drug development.

  4. CRISPR/Cas9-Directed Gene Editing for the Generation of Loss-of-Function Mutants in High-Throughput Zebrafish F0 Screens.

    PubMed

    Shankaran, Sunita S; Dahlem, Timothy J; Bisgrove, Brent W; Yost, H Joseph; Tristani-Firouzi, Martin

    2017-07-05

    The ability to perform reverse genetics in the zebrafish model organism has been greatly advanced with the advent of the CRISPR (clustered regularly interspaced short palindromic repeats)/Cas9 (CRISPR-associated) system. The high level of efficiency in generating mutations when using the CRISPR/Cas9 system combined with the rapid generation time of the zebrafish model organism has made the possibility of performing F 0 screens in this organism a reality. This unit describes a detailed protocol for performing an F 0 screen using the CRISPR/Cas9 system in zebrafish starting with the design and production of custom CRISPR/Cas9 reagents for injection. Next, two approaches for determining the efficiency of mutation induction by the custom CRISPR/Cas9 reagents that are easily performed using standard molecular biology protocols are detailed. Finally, screening for F 0 induced phenotypes using the zebrafish flh gene as an example is discussed. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  5. Assessment of the Capability of the NGDS Prototype to Replace the JBAIDS for Environmental Sample Analysis

    DTIC Science & Technology

    2016-11-01

    FilmArray system. 15. SUBJECT TERMS BioFire FilmArray system Dry Filter Unit (DFU) Joint Biological...collectors, such as the Dry Filter Unit (DFU). The FilmArray system showed enormous potential to rapidly screen samples for a wide range of biological...specific focus on the efficient implementation of environmental detectors and collectors, such as Dry Filter Units (DFUs). The JUPITR ATD members

  6. Battling Malaria in Rural Zambia with Modern Technology: A Qualitative Study on the Value of Cell Phones, Geographical Information Systems, Asymptomatic Carriers and Rapid Diagnostic Tests to Identify, Treat and Control Malaria.

    PubMed

    Nygren, David; Isaksson, Arvid Lissel

    2014-02-04

    During the last decade much progress has been made in reducing malaria transmission in Macha, Southern Province, Zambia. Introduction of artemisinin combination therapies as well as mass screenings of asymptomatic carriers is believed to have contributed the most. When an endemic malaria situation is moving towards a non-endemic situation the resident population loses acquired immunity and therefore active case detection and efficient surveillance is crucial to prevent epidemic outbreaks. Our purpose was to evaluate the impact of cell phone surveillance and geographical information systems on malaria control in Macha. Furthermore, it evaluates what screening and treatment of asymptomatic carriers and implementation of rapid diagnostic tests in rural health care has led to. Ten in-depth semi-structured interviews, field observations and data collection were performed at the Macha Research Trust and at surrounding rural health centers. This qualitative method was inspired by rapid assessment procedure. The cell phone surveillance has been easily integrated in health care, and its integration with Geographical Information Systems has provided the ability to follow malaria transmission on a weekly basis. In addition, active case detection of asymptomatic carriers has been fruitful, which is reflected in it soon being applied nationwide. Furthermore, rapid diagnostic tests have provided rural health centers with reliable malaria diagnostics, thereby decreasing excessive malaria treatments and selection for drug resistance. This report reflects the importance of asymptomatic carriers in targeting malaria elimination, as well as development of effective surveillance systems when transmission decreases. Such an approach would be cost-efficient in the long run through positive effects in reduced child mortality and relief in health care.

  7. In vivo simultaneous transcriptional activation of multiple genes in the brain using CRISPR-dCas9-activator transgenic mice.

    PubMed

    Zhou, Haibo; Liu, Junlai; Zhou, Changyang; Gao, Ni; Rao, Zhiping; Li, He; Hu, Xinde; Li, Changlin; Yao, Xuan; Shen, Xiaowen; Sun, Yidi; Wei, Yu; Liu, Fei; Ying, Wenqin; Zhang, Junming; Tang, Cheng; Zhang, Xu; Xu, Huatai; Shi, Linyu; Cheng, Leping; Huang, Pengyu; Yang, Hui

    2018-03-01

    Despite rapid progresses in the genome-editing field, in vivo simultaneous overexpression of multiple genes remains challenging. We generated a transgenic mouse using an improved dCas9 system that enables simultaneous and precise in vivo transcriptional activation of multiple genes and long noncoding RNAs in the nervous system. As proof of concept, we were able to use targeted activation of endogenous neurogenic genes in these transgenic mice to directly and efficiently convert astrocytes into functional neurons in vivo. This system provides a flexible and rapid screening platform for studying complex gene networks and gain-of-function phenotypes in the mammalian brain.

  8. Rapid Catalyst Screening by a Continuous-Flow Microreactor Interfaced with Ultra High Pressure Liquid Chromatography

    PubMed Central

    Fang, Hui; Xiao, Qing; Wu, Fanghui; Floreancig, Paul E.; Weber, Stephen G.

    2010-01-01

    A high-throughput screening system for homogeneous catalyst discovery has been developed by integrating a continuous-flow capillary-based microreactor with ultra-high pressure liquid chromatography (UHPLC) for fast online analysis. Reactions are conducted in distinct and stable zones in a flow stream that allows for time and temperature regulation. UHPLC detection at high temperature allows high throughput online determination of substrate, product, and byproduct concentrations. We evaluated the efficacies of a series of soluble acid catalysts for an intramolecular Friedel-Crafts addition into an acyliminium ion intermediate within one day and with minimal material investment. The effects of catalyst loading, reaction time, and reaction temperature were also screened. This system exhibited high reproducibility for high-throughput catalyst screening and allowed several acid catalysts for the reaction to be identified. Major side products from the reactions were determined through off-line mass spectrometric detection. Er(OTf)3, the catalyst that showed optimal efficiency in the screening, was shown to be effective at promoting the cyclization reaction on a preparative scale. PMID:20666502

  9. Screening protocol for Torulopsis (Candida) glabrata.

    PubMed Central

    Land, G; Burke, J; Shelby, C; Rhodes, J; Collett, J; Bennett, I; Johnson, J

    1996-01-01

    A screening test has been developed for the presumptive identification of Torulopsis (Candida) glabrata from other common clinical isolates of yeast-like fungi. An interlaboratory comparison of a protocol consisting of morphology on cornmeal Tween 80 agar and trehalose fermentation at 42 degrees C was successful in differentiating T. glabrata from other taxa that are frequent or possible clinical isolates. The screening results for 517 clinical yeast isolates, 241 of which were T. glabrata, were compared with their final identification via commercial systems (API20C Yeast Identification System [bioMERIEUX, Hazelwood, Mo.] and Rapid Yeast Identification Panel [Dade Microscan, Sacramento, Calif.]). The trehalose screening test has a sensitivity and a specificity of 97.8 and 95.8%, respectively, and a positive predictive value of 97.4% and a negative predictive value of 96.5%. Overall, the trehalose screen had an efficiency rating of 93.9% for ruling in or out T. glabrata. Since T. glabrata represents a substantial part of the workload in a clinical laboratory, a significant reduction in direct and indirect costs should be realized. PMID:8862605

  10. Cost-effectiveness analysis of cervical cancer prevention based on a rapid human papillomavirus screening test in a high-risk region of China.

    PubMed

    Levin, Carol E; Sellors, John; Shi, Ju-Fang; Ma, Li; Qiao, You-lin; Ortendahl, Jesse; O'Shea, Meredith K H; Goldie, Sue J

    2010-09-01

    This study assessed the cost-effectiveness of a new, rapid human papillomavirus (HPV)-DNA screening test for cervical cancer prevention in the high-risk region of Shanxi, China. Using micro-costing methods, we estimated the resources needed to implement preventive strategies using cervical cytology or HPV-DNA testing, including the Hybrid Capture 2 (hc2) test (QIAGEN Corp., Gaithersburg, MD) and the rapid HPV-DNA careHPV test (QIAGEN). Data were used in a previously published model and empirically calibrated to country-specific epidemiological data. Strategies differed by initial test, targeted age, frequency of screening, number of clinic visits required (1, 2 or 3) and service delivery setting (national, county and township levels). Outcomes included lifetime risk of cancer, years of life saved (YLS), lifetime costs and incremental cost-effectiveness ratios (cost per YLS). For all screening frequencies, the most efficient strategy used 2-visit rapid HPV-DNA testing at the county level, including screening and diagnostics in the first visit, and treatment in the second visit. Screening at ages 35, 40 and 45 reduced cancer risk by 50% among women compliant with all 3 screening rounds, and was US$ 150 per YLS, compared with this same strategy applied twice per lifetime. This would be considered very cost-effective evaluated against China's per-capita gross domestic product (US$ 1,702). By enhancing the linkage between screening and treatment through a reduced number of visits, rapid HPV-DNA testing 3 times per lifetime is more effective than traditional cytology, and is likely to be cost-effective in high-risk regions of China.

  11. THE RAPID OPTICAL TOOL (TM) LASER-INDUCED FLUORESCENCE SYSTEM FOR SCREENING OF PETROLEUM HYDROCARBONS IN SUBSURFACE SOILS

    EPA Science Inventory

    The Consortium for Site Characterization Technology (CSCT) has established a formal program to accelerate acceptance and application of innovative monitoring and site characterization technologies that improve the way the nation manages its environmental problems. In 1995 the CS...

  12. Acute Neuroactive Drug Exposures alter Locomotor Activity in Larval Zebrafish

    EPA Science Inventory

    As part of the development of a rapid in vivo screen for prioritization of toxic chemicals, we have begun to characterize the locomotor activity of zebrafish (Danio rerio) larvae by assessing the acute effects of prototypic drugs that act on the central nervous system. Initially,...

  13. Integrated Field Screening for Rapid Sediment Characterization

    DTIC Science & Technology

    2004-08-01

    operating procedure SOW statement of work sq square mile(s) SSC San Diego–Space and Naval Warfare Systems Center, San Diego TBT tributyltin ...PCBs], tributyltin [ TBT ]), the data show these areas not very contaminated. 3.4 PHYSICAL SET-UP AND OPERATION The details of the methodology for the

  14. Total body photography for skin cancer screening.

    PubMed

    Dengel, Lynn T; Petroni, Gina R; Judge, Joshua; Chen, David; Acton, Scott T; Schroen, Anneke T; Slingluff, Craig L

    2015-11-01

    Total body photography may aid in melanoma screening but is not widely applied due to time and cost. We hypothesized that a near-simultaneous automated skin photo-acquisition system would be acceptable to patients and could rapidly obtain total body images that enable visualization of pigmented skin lesions. From February to May 2009, a study of 20 volunteers was performed at the University of Virginia to test a prototype 16-camera imaging booth built by the research team and to guide development of special purpose software. For each participant, images were obtained before and after marking 10 lesions (five "easy" and five "difficult"), and images were evaluated to estimate visualization rates. Imaging logistical challenges were scored by the operator, and participant opinion was assessed by questionnaire. Average time for image capture was three minutes (range 2-5). All 55 "easy" lesions were visualized (sensitivity 100%, 90% CI 95-100%), and 54/55 "difficult" lesions were visualized (sensitivity 98%, 90% CI 92-100%). Operators and patients graded the imaging process favorably, with challenges identified regarding lighting and positioning. Rapid-acquisition automated skin photography is feasible with a low-cost system, with excellent lesion visualization and participant acceptance. These data provide a basis for employing this method in clinical melanoma screening. © 2014 The International Society of Dermatology.

  15. Suspect Screening of Chemicals in Consumer Products

    EPA Science Inventory

    This presentation details a pilot suspect screening analysis (SSA) of common consumer products done under the Rapid Exposure and Dosimetry project of CSS. This work presents methods which can rapidly characterize chemicals identified in consumer products including formulations (s...

  16. Evaluation of Five Chromogenic Agar Media and the Rosco Rapid Carb Screen Kit for Detection and Confirmation of Carbapenemase Production in Gram-Negative Bacilli

    PubMed Central

    Gilmour, Matthew W.; DeGagne, Pat; Nichol, Kim; Karlowsky, James A.

    2014-01-01

    An efficient workflow to screen for and confirm the presence of carbapenemase-producing Gram-negative bacilli was developed by evaluating five chromogenic screening agar media and two confirmatory assays, the Rapid Carb screen test (Rosco Diagnostica A/S, Taastrup, Denmark) and the modified Hodge test. A panel of 150 isolates was used, including 49 carbapenemase-producing isolates representing a variety of β-lactamase enzyme classes. An evaluation of analytical performance, assay cost, and turnaround time indicated that the preferred workflow (screening test followed by confirmatory testing) was the chromID Carba agar medium (bioMérieux, Marcy l'Étoile, France), followed by the Rapid Carb screen test, yielding a combined sensitivity of 89.8% and a specificity of 100%. As an optional component of the workflow, a determination of carbapenemase gene class via molecular means could be performed subsequent to confirmatory testing. PMID:25355764

  17. Routine bacterial screening of apheresis platelets on Day 4 using a rapid test: a 4-year single-center experience.

    PubMed

    Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M

    2013-10-01

    The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.

  18. Centrifugal Sieve for Gravity-Level-Independent Size Segregation of Granular Materials

    NASA Technical Reports Server (NTRS)

    Walton, Otis R.; Dreyer, Christopher; Riedel, Edward

    2013-01-01

    Conventional size segregation or screening in batch mode, using stacked vibrated screens, is often a time-consuming process. Utilization of centrifugal force instead of gravity as the primary body force can significantly shorten the time to segregate feedstock into a set of different-sized fractions. Likewise, under reduced gravity or microgravity, a centrifugal sieve system would function as well as it does terrestrially. When vibratory and mechanical blade sieving screens designed for terrestrial conditions were tested under lunar gravity conditions, they did not function well. The centrifugal sieving design of this technology overcomes the issues that prevented sieves designed for terrestrial conditions from functioning under reduced gravity. These sieves feature a rotating outer (cylindrical or conical) screen wall, rotating fast enough for the centrifugal forces near the wall to hold granular material against the rotating screen. Conventional centrifugal sieves have a stationary screen and rapidly rotating blades that shear the granular solid near the stationary screen, and effect the sieving process assisted by the airflow inside the unit. The centrifugal sieves of this new design may (or may not) have an inner blade or blades, moving relative to the rotating wall screen. Some continuous flow embodiments would have no inner auger or blades, but achieve axial motion through vibration. In all cases, the shearing action is gentler than conventional centrifugal sieves, which have very high velocity differences between the stationary outer screen and the rapidly rotating blades. The new design does not depend on airflow in the sieving unit, so it will function just as well in vacuum as in air. One advantage of the innovation for batch sieving is that a batch-mode centrifugal sieve may accomplish the same sieving operation in much less time than a conventional stacked set of vibrated screens (which utilize gravity as the primary driving force for size separation). In continuous mode, the centrifugal sieves can provide steady streams of fine and coarse material separated from a mixed feedstock flow stream. The centrifugal sieves can be scaled to any desired size and/or mass flow rate. Thus, they could be made in sizes suitable for small robotic exploratory missions, or for semi-permanent processing of regolith for extraction of volatiles of minerals. An advantage of the continuous-mode system is that it can be made with absolutely no gravity flow components for feeding material into, or for extracting the separated size streams from, the centrifugal sieve. Thus, the system is capable of functioning in a true microgravity environment. Another advantage of the continuous-mode system is that some embodiments of the innovation have no internal blades or vanes, and thus, can be designed to handle a very wide range of feedstock sizes, including occasional very large oversized pieces, without jamming or seizing up.

  19. The HDAC Inhibitor TSA Ameliorates a Zebrafish Model of Duchenne Muscular Dystrophy.

    PubMed

    Johnson, Nathan M; Farr, Gist H; Maves, Lisa

    2013-09-17

    Zebrafish are an excellent model for Duchenne muscular dystrophy. In particular, zebrafish provide a system for rapid, easy, and low-cost screening of small molecules that can ameliorate muscle damage in dystrophic larvae. Here we identify an optimal anti-sense morpholino cocktail that robustly knocks down zebrafish Dystrophin (dmd-MO). We use two approaches, muscle birefringence and muscle actin expression, to quantify muscle damage and show that the dmd-MO dystrophic phenotype closely resembles the zebrafish dmd mutant phenotype. We then show that the histone deacetylase (HDAC) inhibitor TSA, which has been shown to ameliorate the mdx mouse Duchenne model, can rescue muscle fiber damage in both dmd-MO and dmd mutant larvae. Our study identifies optimal morpholino and phenotypic scoring approaches for dystrophic zebrafish, further enhancing the zebrafish dmd model for rapid and cost-effective small molecule screening.

  20. Accelerated exploration of multi-principal element alloys with solid solution phases

    PubMed Central

    Senkov, O.N.; Miller, J.D.; Miracle, D.B.; Woodward, C.

    2015-01-01

    Recent multi-principal element, high entropy alloy (HEA) development strategies vastly expand the number of candidate alloy systems, but also pose a new challenge—how to rapidly screen thousands of candidate alloy systems for targeted properties. Here we develop a new approach to rapidly assess structural metals by combining calculated phase diagrams with simple rules based on the phases present, their transformation temperatures and useful microstructures. We evaluate over 130,000 alloy systems, identifying promising compositions for more time-intensive experimental studies. We find the surprising result that solid solution alloys become less likely as the number of alloy elements increases. This contradicts the major premise of HEAs—that increased configurational entropy increases the stability of disordered solid solution phases. As the number of elements increases, the configurational entropy rises slowly while the probability of at least one pair of elements favouring formation of intermetallic compounds increases more rapidly, explaining this apparent contradiction. PMID:25739749

  1. Combinatorial Methodology for Screening Selectivity in Polymeric Pervaporation Membranes.

    PubMed

    Godbole, Rutvik V; Ma, Lan; Doerfert, Michael D; Williams, Porsche; Hedden, Ronald C

    2015-11-09

    Combinatorial methodology is described for rapid screening of selectivity in polymeric pervaporation membrane materials for alcohol-water separations. The screening technique is demonstrated for ethanol-water separation using a model polyacrylate system. The materials studied are cross-linked random copolymers of a hydrophobic comonomer (n-butyl acrylate, B) and a hydrophilic comonomer (2-hydroxyethyl acrylate, H). A matrix of materials is prepared that has orthogonal variations in two key variables, H:B ratio and cross-linker concentration. For mixtures of ethanol and water, equilibrium selectivities and distribution coefficients are obtained by combining swelling measurements with high-throughput HPLC analysis. Based on the screening results, two copolymers are selected for further study as pervaporation membranes to quantify permeability selectivity and the flux of ethanol. The screening methodology described has good potential to accelerate the search for new membrane materials, as it is adaptable to a broad range of polymer chemistries.

  2. Virtual Liver: Quantitative Dose-Response Using Systems Biology

    EPA Science Inventory

    The U.S. EPA’s ToxCast™ program uses hundreds of high-throughput, in vitro assays to screen chemicals in order to rapidly identify signatures of toxicity. These assays measure the in vitro concentrations at which cellular pathways are perturbed by chemicals. The U.S. EPA’s Virtu...

  3. Drugs Targeting the Dopaminergic Nervous System Alter Locomotion in Larval Zebrafish

    EPA Science Inventory

    As part of an effort at the US Environmental Protection Agency to develop a rapid in vivo screen for prioritization of toxic chemicals, we have begun to characterize the locomotor activity of zebrafish (Danio rerio) larvae. This includes assessing the acute effects of drugs that ...

  4. Acute neuroactive drug exposures alter locomotor activity in larval zebrafish

    EPA Science Inventory

    In an effort to develop a rapid in vivo screen for EPA's prioritization of toxic chemicals, we are characterizing the locomotor activity of zebrafish (Danio rerio) larvae after exposure to prototypic drugs that act on the central nervous system. MPTP (1-methyl-4phenyl- 1 ,2,3,6-...

  5. Developmental Exposure to a Dopaminergic Toxicant Produces Altered Locomotor Activity in Larval Zebrafish

    EPA Science Inventory

    In an effort to develop a rapid in vivo screen for EPA’s prioritization of toxic chemicals, we are characterizing the locomotor activity of zebrafish (Danio rerio) larvae after developmental exposure to various classes of prototypic drugs that act on the central nervous system. ...

  6. Emergency department patient perceptions and preferences on opt-in rapid HIV screening program components

    PubMed Central

    Merchant, Roland C.; Clark, Melissa A.; Seage, George R.; Mayer, Kenneth H.; DeGruttola, Victor G.; Becker, Bruce M.

    2011-01-01

    The aim of this investigation was to assess emergency department (ED) patients’ perceptions and preferences about an opt-in, universal, rapid HIV screening program and identify patient groups who expressed stronger beliefs about components of the testing program. From July 2005 to July 2006, ED patients in the opt-in, universal, rapid HIV screening program were interviewed in person. Multivariable regression models were used to compare participants on their beliefs about the program components. Of the 561 participants, 62.0% had previously been tested for HIV. The majority of participants (58.8%) believed the rapid and standard/conventional HIV tests to be equally accurate, 27.7% believed the rapid test to be less or much less accurate, and 8.7% believed the rapid test to be more or much more accurate. Almost two-thirds (65.1%) favored having a rapid instead of a standard/conventional HIV test, 94.6% wanted the test results within one hour, and 61.3% would be likely or very likely to undergo testing in the ED if it prolonged their ED visit. Almost all (92.5%) believed that their medical care was “not at all” delayed because of being tested, 94.1% believed that testing did “not at all” divert attention from the reason for their ED visit, and 80.9% thought that testing in the ED was “not at all” stressful. In multivariable logistic regression models, males and those with more than 12 years of formal education showed greater concerns about the rapid HIV test’s accuracy. Hispanic/Latinos, participants with governmental insurance, and those previously HIV tested were more apt to be screened for HIV even if testing delayed their ED departure. Overall, participants were highly accepting of the components of this opt-in rapid HIV screening program. However, concerns regarding the accuracy of the rapid HIV test might limit test acceptance and should be addressed during pre-test information procedures. PMID:19283644

  7. Rapid, Optimized Interactomic Screening

    PubMed Central

    Hakhverdyan, Zhanna; Domanski, Michal; Hough, Loren; Oroskar, Asha A.; Oroskar, Anil R.; Keegan, Sarah; Dilworth, David J.; Molloy, Kelly R.; Sherman, Vadim; Aitchison, John D.; Fenyö, David; Chait, Brian T.; Jensen, Torben Heick; Rout, Michael P.; LaCava, John

    2015-01-01

    We must reliably map the interactomes of cellular macromolecular complexes in order to fully explore and understand biological systems. However, there are no methods to accurately predict how to capture a given macromolecular complex with its physiological binding partners. Here, we present a screen that comprehensively explores the parameters affecting the stability of interactions in affinity-captured complexes, enabling the discovery of physiological binding partners and the elucidation of their functional interactions in unparalleled detail. We have implemented this screen on several macromolecular complexes from a variety of organisms, revealing novel profiles even for well-studied proteins. Our approach is robust, economical and automatable, providing an inroad to the rigorous, systematic dissection of cellular interactomes. PMID:25938370

  8. Screening for acute HIV infection in South Africa: finding acute and chronic disease

    PubMed Central

    Bassett, Ingrid V.; Chetty, Senica; Giddy, Janet; Reddy, Shabashini; Bishop, Karen; Lu, Zhigang; Losina, Elena; Freedberg, Kenneth A.; Walensky, Rochelle P.

    2010-01-01

    Background The yield of screening for acute HIV infection among general medical patients in resource-scarce settings remains unclear. Our objective was to evaluate a strategy of pooled HIV plasma RNA to diagnose acute HIV infection in patients with negative or discordant rapid HIV antibody tests in Durban, South Africa. Methods We prospectively enrolled patients with negative or discordant rapid HIV antibody tests from a routine HIV screening program in an outpatient department in Durban with an HIV prevalence of 48%. Study participants underwent venipuncture for pooled qualitative HIV RNA, and if positive, quantitative RNA, enzyme immunoassay and Western Blot (WB). Patients with negative or indeterminate WB and positive quantitative HIV RNA were considered acutely infected. Those with chronic infection (positive RNA and WB) despite negative or discordant rapid HIV tests were considered false negative rapid antibody tests. Results Nine hundred ninety-four participants were enrolled with either negative (N=976) or discordant (N=18) rapid test results. Eleven (1.1%, 95% CI: 0.6–2.0%) had acute HIV infection. Of the 994 patients, an additional 20 (2.0%, 95% CI: 1.3–.3.1%) had chronic HIV infection (false negative rapid test). Conclusions One percent of outpatients with negative or discordant rapid HIV tests in Durban, South Africa had acute HIV infection readily detectable through pooled serum HIV RNA screening. Pooled RNA testing also identified an additional 2% of patients with chronic HIV infection. HIV RNA screening has the potential to identify both acute and chronic HIV infections that are otherwise missed by standard HIV testing algorithms. PMID:20553336

  9. Rapid Syphilis Tests as Catalysts for Health Systems Strengthening: A Case Study from Peru

    PubMed Central

    García, Patricia J.; Cárcamo, César P.; Chiappe, Marina; Valderrama, Maria; La Rosa, Sayda; Holmes, King K.; Mabey, David C. W.; Peeling, Rosanna W.

    2013-01-01

    Objectives Untreated maternal syphilis leads to adverse pregnancy outcomes. The use of point of care tests (POCT) offers an opportunity to improve screening coverage for syphilis and other aspects of health systems. Our objective is to present the experience of the introduction of POCT for syphilis in Peru and describe how new technology can catalyze health system strengthening. Methods The study was implemented from September 2009–November 2010 to assess the feasibility of the use of a POCT for syphilis for screening pregnant women in Lima, Peru. Outcomes measured included access to syphilis screening, treatment coverage, partner treatment, effect on patient flow and service efficiency, acceptability among providers and patients, and sustainability. Results Before the introduction of POCT, a pregnant woman needed 6 visits to the health center in 27 days before she received her syphilis result. We trained 604 health providers and implemented the POCT for syphilis as the “two for one strategy”, offering with one finger stick both syphilis and HIV testing. Implementation of the POCT resulted in testing and treatment on the first visit. Screening and treatment coverages for syphilis improved significantly compared with the previous year. Implementation of POCT has been scaled up nationally since the study ended, and coverages for screening, treatment and partner treatment have remained over 92%. Conclusions Implementation of POCT for syphilis proved feasible and acceptable, and led to improvement in several aspects of health services. For the process to be effective we highlight the importance of: (1) engaging the authorities; (2) dissipating tensions between providers and identifying champions; (3) training according to the needs; (4) providing monitoring, supervision, support and recognition; (5) sharing results and discussing actions together; (6) consulting and obtaining feedback from users; and (7) integrating with other services such as with rapid HIV testing. PMID:23840552

  10. Testing and failure analysis to improve screening techniques for hermetically sealed metallized film capacitors for low energy applications

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Effective screening techniques are evaluated for detecting insulation resistance degradation and failure in hermetically sealed metallized film capacitors used in applications where low capacitor voltage and energy levels are common to the circuitry. A special test and monitoring system capable of rapidly scanning all test capacitors and recording faults and/or failures is examined. Tests include temperature cycling and storage as well as low, medium, and high voltage life tests. Polysulfone film capacitors are more heat stable and reliable than polycarbonate film units.

  11. Polyglutamine Disease Modeling: Epitope Based Screen for Homologous Recombination using CRISPR/Cas9 System.

    PubMed

    An, Mahru C; O'Brien, Robert N; Zhang, Ningzhe; Patra, Biranchi N; De La Cruz, Michael; Ray, Animesh; Ellerby, Lisa M

    2014-04-15

    We have previously reported the genetic correction of Huntington's disease (HD) patient-derived induced pluripotent stem cells using traditional homologous recombination (HR) approaches. To extend this work, we have adopted a CRISPR-based genome editing approach to improve the efficiency of recombination in order to generate allelic isogenic HD models in human cells. Incorporation of a rapid antibody-based screening approach to measure recombination provides a powerful method to determine relative efficiency of genome editing for modeling polyglutamine diseases or understanding factors that modulate CRISPR/Cas9 HR.

  12. Rapid screening of tannase producing microbes by using natural tannin

    PubMed Central

    Jana, Arijit; Maity, Chiranjit; Halder, Suman Kumar; Pati, Bikas Ranjan; Mondal, Keshab Chandra; Mohapatra, Pradeep Kumar Das

    2012-01-01

    Use of natural tannin in the screening of tannase producing microbes is really promising. The present work describes about the possibility and integrity of the newly formulated method over the previously reported methods. Tannin isolated from Terminalia belerica Roxb. (Bahera) was used to differentiate between tanninolytic and nontanninolytic microbes. The method is simple, sensitive and superior for the rapid screening and isolation of tannase-producing microbes. PMID:24031931

  13. Rapid screening of tannase producing microbes by using natural tannin.

    PubMed

    Jana, Arijit; Maity, Chiranjit; Halder, Suman Kumar; Pati, Bikas Ranjan; Mondal, Keshab Chandra; Mohapatra, Pradeep Kumar Das

    2012-07-01

    Use of natural tannin in the screening of tannase producing microbes is really promising. The present work describes about the possibility and integrity of the newly formulated method over the previously reported methods. Tannin isolated from Terminalia belerica Roxb. (Bahera) was used to differentiate between tanninolytic and nontanninolytic microbes. The method is simple, sensitive and superior for the rapid screening and isolation of tannase-producing microbes.

  14. Medium-Throughput Screen of Microbially Produced Serotonin via a G-Protein-Coupled Receptor-Based Sensor.

    PubMed

    Ehrenworth, Amy M; Claiborne, Tauris; Peralta-Yahya, Pamela

    2017-10-17

    Chemical biosensors, for which chemical detection triggers a fluorescent signal, have the potential to accelerate the screening of noncolorimetric chemicals produced by microbes, enabling the high-throughput engineering of enzymes and metabolic pathways. Here, we engineer a G-protein-coupled receptor (GPCR)-based sensor to detect serotonin produced by a producer microbe in the producer microbe's supernatant. Detecting a chemical in the producer microbe's supernatant is nontrivial because of the number of other metabolites and proteins present that could interfere with sensor performance. We validate the two-cell screening system for medium-throughput applications, opening the door to the rapid engineering of microbes for the increased production of serotonin. We focus on serotonin detection as serotonin levels limit the microbial production of hydroxystrictosidine, a modified alkaloid that could accelerate the semisynthesis of camptothecin-derived anticancer pharmaceuticals. This work shows the ease of generating GPCR-based chemical sensors and their ability to detect specific chemicals in complex aqueous solutions, such as microbial spent medium. In addition, this work sets the stage for the rapid engineering of serotonin-producing microbes.

  15. Data-driven decision support for radiologists: re-using the National Lung Screening Trial dataset for pulmonary nodule management.

    PubMed

    Morrison, James J; Hostetter, Jason; Wang, Kenneth; Siegel, Eliot L

    2015-02-01

    Real-time mining of large research trial datasets enables development of case-based clinical decision support tools. Several applicable research datasets exist including the National Lung Screening Trial (NLST), a dataset unparalleled in size and scope for studying population-based lung cancer screening. Using these data, a clinical decision support tool was developed which matches patient demographics and lung nodule characteristics to a cohort of similar patients. The NLST dataset was converted into Structured Query Language (SQL) tables hosted on a web server, and a web-based JavaScript application was developed which performs real-time queries. JavaScript is used for both the server-side and client-side language, allowing for rapid development of a robust client interface and server-side data layer. Real-time data mining of user-specified patient cohorts achieved a rapid return of cohort cancer statistics and lung nodule distribution information. This system demonstrates the potential of individualized real-time data mining using large high-quality clinical trial datasets to drive evidence-based clinical decision-making.

  16. A rapid enzymatic assay for high-throughput screening of adenosine-producing strains

    PubMed Central

    Dong, Huina; Zu, Xin; Zheng, Ping; Zhang, Dawei

    2015-01-01

    Adenosine is a major local regulator of tissue function and industrially useful as precursor for the production of medicinal nucleoside substances. High-throughput screening of adenosine overproducers is important for industrial microorganism breeding. An enzymatic assay of adenosine was developed by combined adenosine deaminase (ADA) with indophenol method. The ADA catalyzes the cleavage of adenosine to inosine and NH3, the latter can be accurately determined by indophenol method. The assay system was optimized to deliver a good performance and could tolerate the addition of inorganic salts and many nutrition components to the assay mixtures. Adenosine could be accurately determined by this assay using 96-well microplates. Spike and recovery tests showed that this assay can accurately and reproducibly determine increases in adenosine in fermentation broth without any pretreatment to remove proteins and potentially interfering low-molecular-weight molecules. This assay was also applied to high-throughput screening for high adenosine-producing strains. The high selectivity and accuracy of the ADA assay provides rapid and high-throughput analysis of adenosine in large numbers of samples. PMID:25580842

  17. Test and evaluation of the 2.4-micron photorefractor ocular screening system

    NASA Technical Reports Server (NTRS)

    Richardson, J. R.

    1985-01-01

    An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.

  18. A rapid screen for four corticosteroids in equine synovial fluid.

    PubMed

    Agrawal, Karan; Ebel, Joseph G; Bischoff, Karyn

    2014-06-01

    Most antidoping method development in the equine industry has been for plasma and urine, though there has been recent interest in the analysis of synovial fluid for evidence of doping by intra-articular corticosteroid injection. Published methods for corticosteroid analysis in synovial fluid are primarily singleplex methods, do not screen for all corticosteroids of interest and are not adequately sensitive. The purpose of this study is to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) screening method for the detection of four of the most common intra-articularly administered corticosteroids--betamethasone, methylprednisolone, methylprednisolone acetate and triamcinolone acetonide. Sample preparation consisted of protein precipitation followed by a basified liquid-liquid extraction. LC-MS-MS experiments consisted of a six-min isocratic separation using a Phenomenex Polar-RP stationary phase and a mobile phase consisting of 35% acetonitrile, 5 mM ammonium acetate and 0.1% formic acid in nanopure water. The detection system used was a triple quadrupole mass analyzer with thermospray ionization, and compounds were identified using selective reaction monitoring. The method was validated to the ISO/IEC 17025 standard, and real synovial fluid samples were analyzed to demonstrate the application of the method in an antidoping context. The method was highly selective for the four corticosteroids with limits of detection of 1-3 ng/mL. The extraction efficiency was 50-101%, and the matrix effects were 14-31%. These results indicate that the method is a rapid and sensitive screen for the four corticosteroids in equine synovial fluid, fit for purpose for equine antidoping assays.

  19. Screening and characterization of novel bacteriocins from lactic acid bacteria.

    PubMed

    Zendo, Takeshi

    2013-01-01

    Bacteriocins produced by lactic acid bacteria (LAB) are expected to be safe antimicrobial agents. While the best studied LAB bacteriocin, nisin A, is widely utilized as a food preservative, various novel ones are required to control undesirable bacteria more effectively. To discover novel bacteriocins at the early step of the screening process, we developed a rapid screening system that evaluates bacteriocins produced by newly isolated LAB based on their antibacterial spectra and molecular masses. By means of this system, various novel bacteriocins were identified, including a nisin variant, nisin Q, a two-peptide bacteriocin, lactococcin Q, a leaderless bacteriocin, lacticin Q, and a circular bacteriocin, lactocyclicin Q. Moreover, some LAB isolates were found to produce multiple bacteriocins. They were characterized as to their structures, mechanisms of action, and biosynthetic mechanisms. Novel LAB bacteriocins and their biosynthetic mechanisms are expected for applications such as food preservation and peptide engineering.

  20. PAPNET-assisted primary screening of conventional cervical smears.

    PubMed

    Cenci, M; Nagar, C; Vecchione, A

    2000-01-01

    The PAPNET System is the only device with a neural-network-based-artificial intelligence to detect and show the images of abnormal cells on the monitor to be evaluated in an interactive way. We effectively used the PAPNET in rescreening of conventional cervical smears and we detected its advantages and its disadvantages. In this paper, we report our results from PAPNET-assisted primary screening performed on 20,154 conventional smears. The smears were classified as Negative or as Review. The Negative cases were rapidly rescreened mainly near the coverslip edges, which are the slide areas not analyzed by automated devices because of focusing problems. The Review cases were fully reanalyzed by the optic microscope. In summary, 140 positive smears were detected: 57 cases showed changes due to HPV, 63 LSIL, 15 HSIL, and 5 carcinomas. Therefore, the PAPNET System was confirmed as useful in primary screening of conventional cervical samples as well as rescreening.

  1. Wearable Wireless Tyrosinase Bandage and Microneedle Sensors: Toward Melanoma Screening.

    PubMed

    Ciui, Bianca; Martin, Aida; Mishra, Rupesh K; Brunetti, Barbara; Nakagawa, Tatsuo; Dawkins, Thomas J; Lyu, Mengjia; Cristea, Cecilia; Sandulescu, Robert; Wang, Joseph

    2018-04-01

    Wearable bendable bandage-based sensor and a minimally invasive microneedle biosensor are described toward rapid screening of skin melanoma. These wearable electrochemical sensors are capable of detecting the presence of the tyrosinase (TYR) enzyme cancer biomarker in the presence of its catechol substrate, immobilized on the transducer surface. In the presence of the surface TYR biomarker, the immobilized catechol is rapidly converted to benzoquinone that is detected amperometrically, with a current signal proportional to the TYR level. The flexible epidermal bandage sensor relies on printing stress-enduring inks which display good resiliency against mechanical deformations, whereas the hollow microneedle device is filled with catechol-coated carbon paste for assessing tissue TYR levels. The bandage sensor can thus be used directly on the skin whereas microneedle device can reach melanoma tissues under the skin. Both wearable sensors are interfaced to an ultralight flexible electronic board, which transmits data wirelessly to a mobile device. The analytical performance of the resulting bandage and microneedle sensing systems are evaluated using TYR-containing agarose phantom gel and porcine skin. The new integrated conformal portable sensing platforms hold considerable promise for decentralized melanoma screening, and can be extended to the screening of other key biomarkers in skin moles. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. High-performance liquid chromatography coupled with post-column dual-bioactivity assay for simultaneous screening of xanthine oxidase inhibitors and free radical scavengers from complex mixture.

    PubMed

    Li, D Q; Zhao, J; Li, S P

    2014-06-06

    Xanthine oxidase (XO) can catalyze hypoxanthine and xanthine to generate uric acid and reactive oxygen species (ROS), including superoxide anion radical (O₂(•-)) and hydrogen peroxide. XO inhibitors and free radical scavengers are beneficial to the treatment of gout and many related diseases. In the present study, an on-line high-performance liquid chromatography (HPLC) coupled with post-column dual-bioactivity assay was established and successfully applied to simultaneously screening of XO inhibitors and free radical scavengers from a complex mixture, Oroxylum indicum extract. The integrated system of HPLC separation, bioactivity screening and mass spectrometry identification was proved to be simple and effective for rapid and sensitive screening of individual bioactive compounds in complex mixtures. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A cell-based assay for aggregation inhibitors as therapeutics of polyglutamine-repeat disease and validation in Drosophila

    NASA Astrophysics Data System (ADS)

    Apostol, Barbara L.; Kazantsev, Alexsey; Raffioni, Simona; Illes, Katalin; Pallos, Judit; Bodai, Laszlo; Slepko, Natalia; Bear, James E.; Gertler, Frank B.; Hersch, Steven; Housman, David E.; Marsh, J. Lawrence; Michels Thompson, Leslie

    2003-05-01

    The formation of polyglutamine-containing aggregates and inclusions are hallmarks of pathogenesis in Huntington's disease that can be recapitulated in model systems. Although the contribution of inclusions to pathogenesis is unclear, cell-based assays can be used to screen for chemical compounds that affect aggregation and may provide therapeutic benefit. We have developed inducible PC12 cell-culture models to screen for loss of visible aggregates. To test the validity of this approach, compounds that inhibit aggregation in the PC12 cell-based screen were tested in a Drosophila model of polyglutamine-repeat disease. The disruption of aggregation in PC12 cells strongly correlates with suppression of neuronal degeneration in Drosophila. Thus, the engineered PC12 cells coupled with the Drosophila model provide a rapid and effective method to screen and validate compounds.

  4. Rapid screening natural-origin lipase inhibitors from hypolipidemic decoctions by ultrafiltration combined with liquid chromatography-mass spectrometry.

    PubMed

    Xiao, Shun; Yu, Runru; Ai, Ni; Fan, Xiaohui

    2015-02-01

    Lipase inhibitors generate hypolipidemic effect that is helpful to control or treat some obesity diseases by inactivating catalytic activity of human pancreatic lipase, a key enzyme involved in triglyceride hydrolysis in vivo. Many traditional Chinese medicine (TCM) formulae have been effectively used to treat obesity and other fat related diseases for centuries and modern biological experiments demonstrate therapeutic effect of these formulae can be linked to their lipid-lowering capability in blood. These observations suggest that these hypolipidemic decoctions (HDs) could be a promising resource of natural-origin lipase inhibitors. This work described a rapid approach for screening lipase inhibitors from four widely used HDs, including Wu-Ling-San (WLS), Ze-Xie decoction (ZX), Xiao-Xian-Xiong decoction (XXX) and Xiao-Chai-Hu decoction (XCH), by ultrafiltration combing with high performance liquid chromatography-mass spectrometry (HPLC-MS). Our results showed sixteen natural-origin lipase inhibitors were discovered and identified by high resolution and multistage mass spectrometry. Inhibitory activities of two compounds were confirmed by a functional assay of lipase, which validated the reliability of our approach. Molecular docking simulation was then performed to investigate potential mechanism of action for these compounds. Together we present an efficient method for rapid screening lipase inhibitors from complex natural products, which can be easily accommodated to other important enzymatic system with therapeutic values. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. A colorimetric assay of 1-aminocyclopropane-1-carboxylate (ACC) based on ninhydrin reaction for rapid screening of bacteria containing ACC deaminase.

    PubMed

    Li, Z; Chang, S; Lin, L; Li, Y; An, Q

    2011-08-01

    1-Aminocyclopropane-1-carboxylate (ACC) deaminase activity is an efficient marker for bacteria to promote plant growth by lowering ethylene levels in plants. We aim to develop a method for rapidly screening bacteria containing ACC deaminase, based on a colorimetric ninhydrin assay of ACC. A reliable colorimetric ninhydrin assay was developed to quantify ACC using heat-resistant polypropylene chimney-top 96-well PCR plates, having the wells evenly heated in boiling water, preventing accidental contamination from boiling water and limiting evaporation. With this method to measure bacterial consumption of ACC, 44 ACC-utilizing bacterial isolates were rapidly screened out from 311 bacterial isolates that were able to grow on minimal media containing ACC as the sole nitrogen source. The 44 ACC-utilizing bacterial isolates showed ACC deaminase activities and belonged to the genus Burkholderia, Pseudomonas or Herbaspirillum. Determination of bacterial ACC consumption by the PCR-plate ninhydrin-ACC assay is a rapid and efficient method for screening bacteria containing ACC deaminase from a large number of bacterial isolates. The PCR-plate ninhydrin-ACC assay extends the utility of the ninhydrin reaction and enables a rapid screening of bacteria containing ACC deaminase from large numbers of bacterial isolates. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  6. Routine opt-out rapid HIV screening and detection of HIV infection in emergency department patients.

    PubMed

    Haukoos, Jason S; Hopkins, Emily; Conroy, Amy A; Silverman, Morgan; Byyny, Richard L; Eisert, Sheri; Thrun, Mark W; Wilson, Michael L; Hutchinson, Angela B; Forsyth, Jessica; Johnson, Steven C; Heffelfinger, James D

    2010-07-21

    The Centers for Disease Control and Prevention (CDC) recommends routine (nontargeted) opt-out HIV screening in health care settings, including emergency departments (EDs), where the prevalence of undiagnosed infection is 0.1% or greater. The utility of this approach in EDs remains unknown. To determine whether nontargeted opt-out rapid HIV screening in the ED was associated with identification of more patients with newly diagnosed HIV infection than physician-directed diagnostic rapid HIV testing. Quasi-experimental equivalent time-samples design in an urban public safety-net hospital with an approximate annual ED census of 55,000 patient visits. Patients were 16 years or older and capable of providing consent for rapid HIV testing. Nontargeted opt-out rapid HIV screening and physician-directed diagnostic rapid HIV testing alternated in sequential 4-month time intervals between April 15, 2007, and April 15, 2009. Number of patients with newly identified HIV infection and the association between nontargeted opt-out rapid HIV screening and identification of HIV infection. In the opt-out phase, of 28,043 eligible ED patients, 6933 patients (25%) completed HIV testing (6702 patients were screened; 231 patients were diagnostically tested). Ten of 6702 patients (0.15%; 95% CI, 0.07%-0.27%) who did not decline HIV screening in the opt-out phase had new HIV diagnoses, and 5 of 231 patients (2.2%; 95% CI, 0.7%-5.0%) who were diagnostically tested during the opt-out phase had new HIV diagnoses. In the diagnostic phase, of 29,925 eligible patients, 243 (0.8%) completed HIV testing. Of these, 4 patients (1.6%; 95% CI, 0.5%-4.2%) had new diagnoses. The prevalence of new HIV diagnoses in the opt-out phase (including those diagnostically tested) and in the diagnostic phase was 15 in 28,043 (0.05%; 95% CI, 0.03%-0.09%) and 4 in 29,925 (0.01%; 95% CI, 0.004%-0.03%), respectively. Nontargeted opt-out HIV screening was independently associated with new HIV diagnoses (risk ratio, 3.6; 95% CI, 1.2-10.8) when adjusting for patient demographics, insurance status, and whether diagnostic testing was performed in the opt-out phase. The median CD4 cell count for those with new HIV diagnoses in the opt-out phase (including those diagnostically tested) and in the diagnostic phase was 69/microL (IQR, 17-430) and 13/microL (IQR, 11-15) , respectively (P = .02). Nontargeted opt-out rapid HIV screening in the ED, vs diagnostic testing, was associated with identification of a modestly increased number of patients with new HIV diagnoses, most of whom were identified late in the course of disease.

  7. Fully-Automated High-Throughput NMR System for Screening of Haploid Kernels of Maize (Corn) by Measurement of Oil Content

    PubMed Central

    Xu, Xiaoping; Huang, Qingming; Chen, Shanshan; Yang, Peiqiang; Chen, Shaojiang; Song, Yiqiao

    2016-01-01

    One of the modern crop breeding techniques uses doubled haploid plants that contain an identical pair of chromosomes in order to accelerate the breeding process. Rapid haploid identification method is critical for large-scale selections of double haploids. The conventional methods based on the color of the endosperm and embryo seeds are slow, manual and prone to error. On the other hand, there exists a significant difference between diploid and haploid seeds generated by high oil inducer, which makes it possible to use oil content to identify the haploid. This paper describes a fully-automated high-throughput NMR screening system for maize haploid kernel identification. The system is comprised of a sampler unit to select a single kernel to feed for measurement of NMR and weight, and a kernel sorter to distribute the kernel according to the measurement result. Tests of the system show a consistent accuracy of 94% with an average screening time of 4 seconds per kernel. Field test result is described and the directions for future improvement are discussed. PMID:27454427

  8. Non-natural amino acid peptide microarrays to discover Ebola virus glycoprotein ligands.

    PubMed

    Rabinowitz, Joshua A; Lainson, John C; Johnston, Stephen Albert; Diehnelt, Chris W

    2018-02-06

    We demonstrate a platform to screen a virus pseudotyped with Ebola virus glycoprotein (GP) against a library of peptides that contain non-natural amino acids to develop GP affinity ligands. This system could be used for rapid development of peptide-based antivirals for other emerging or neglected tropical infectious diseases.

  9. The Effects of Acute Exposure to Neuroactive Drugs on the Locomotor Activity of Larval Zebrafish

    EPA Science Inventory

    In an effort to develop a rapid in vivo screen for EPA’s prioritization of toxic chemicals, we have begun to characterize the locomotor activity of zebrafish (Danio rerio) larvae using prototypic drugs that act on the central nervous system. Initially, we chose to define the beh...

  10. Comparison of Refractory Performance in Black Liquor Gasifiers and a Smelt Test System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peascoe, RA

    2001-09-25

    Prior laboratory corrosion studies along with experience at the black liquor gasifier in New Bern, North Carolina, clearly demonstrate that serious material problems exist with the gasifier's refractory lining. Mullite-based and alumina-based refractories used at the New Bern facility suffered significant degradation even though they reportedly performed adequately in smaller scale systems. Oak Ridge National Laboratory's involvement in the failure analysis, and the initial exploration of suitable replacement materials, led to the realization that a simple and reliable, complementary method for refractory screening was needed. The development of a laboratory test system and its suitability for simulating the environment ofmore » black liquor gasifiers was undertaken. Identification and characterization of corrosion products were used to evaluate the test system as a rapid screening tool for refractory performance and as a predictor of refractory lifetime. Results from the test systems and pl ants were qualitatively similar.« less

  11. Programmatic cost evaluation of nontargeted opt-out rapid HIV screening in the emergency department.

    PubMed

    Haukoos, Jason S; Campbell, Jonathan D; Conroy, Amy A; Hopkins, Emily; Bucossi, Meggan M; Sasson, Comilla; Al-Tayyib, Alia A; Thrun, Mark W

    2013-01-01

    The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%-0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%-4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED.

  12. Accurate high-throughput structure mapping and prediction with transition metal ion FRET

    PubMed Central

    Yu, Xiaozhen; Wu, Xiongwu; Bermejo, Guillermo A.; Brooks, Bernard R.; Taraska, Justin W.

    2013-01-01

    Mapping the landscape of a protein’s conformational space is essential to understanding its functions and regulation. The limitations of many structural methods have made this process challenging for most proteins. Here, we report that transition metal ion FRET (tmFRET) can be used in a rapid, highly parallel screen, to determine distances from multiple locations within a protein at extremely low concentrations. The distances generated through this screen for the protein Maltose Binding Protein (MBP) match distances from the crystal structure to within a few angstroms. Furthermore, energy transfer accurately detects structural changes during ligand binding. Finally, fluorescence-derived distances can be used to guide molecular simulations to find low energy states. Our results open the door to rapid, accurate mapping and prediction of protein structures at low concentrations, in large complex systems, and in living cells. PMID:23273426

  13. Combinatorial microfluidic droplet engineering for biomimetic material synthesis

    PubMed Central

    Bawazer, Lukmaan A.; McNally, Ciara S.; Empson, Christopher J.; Marchant, William J.; Comyn, Tim P.; Niu, Xize; Cho, Soongwon; McPherson, Michael J.; Binks, Bernard P.; deMello, Andrew; Meldrum, Fiona C.

    2016-01-01

    Although droplet-based systems are used in a wide range of technologies, opportunities for systematically customizing their interface chemistries remain relatively unexplored. This article describes a new microfluidic strategy for rapidly tailoring emulsion droplet compositions and properties. The approach uses a simple platform for screening arrays of droplet-based microfluidic devices and couples this with combinatorial selection of the droplet compositions. Through the application of genetic algorithms over multiple screening rounds, droplets with target properties can be rapidly generated. The potential of this method is demonstrated by creating droplets with enhanced stability, where this is achieved by selecting carrier fluid chemistries that promote titanium dioxide formation at the droplet interfaces. The interface is a mixture of amorphous and crystalline phases, and the resulting composite droplets are biocompatible, supporting in vitro protein expression in their interiors. This general strategy will find widespread application in advancing emulsion properties for use in chemistry, biology, materials, and medicine. PMID:27730209

  14. Rapid and Facile Microwave-Assisted Surface Chemistry for Functionalized Microarray Slides

    PubMed Central

    Lee, Jeong Heon; Hyun, Hoon; Cross, Conor J.; Henary, Maged; Nasr, Khaled A.; Oketokoun, Rafiou; Choi, Hak Soo; Frangioni, John V.

    2011-01-01

    We describe a rapid and facile method for surface functionalization and ligand patterning of glass slides based on microwave-assisted synthesis and a microarraying robot. Our optimized reaction enables surface modification 42-times faster than conventional techniques and includes a carboxylated self-assembled monolayer, polyethylene glycol linkers of varying length, and stable amide bonds to small molecule, peptide, or protein ligands to be screened for binding to living cells. We also describe customized slide racks that permit functionalization of 100 slides at a time to produce a cost-efficient, highly reproducible batch process. Ligand spots can be positioned on the glass slides precisely using a microarraying robot, and spot size adjusted for any desired application. Using this system, we demonstrate live cell binding to a variety of ligands and optimize PEG linker length. Taken together, the technology we describe should enable high-throughput screening of disease-specific ligands that bind to living cells. PMID:23467787

  15. A screen for immunity genes evolving under positive selection in Drosophila.

    PubMed

    Jiggins, F M; Kim, K W

    2007-05-01

    Genes involved in the immune system tend to have higher rates of adaptive evolution than other genes in the genome, probably because they are coevolving with pathogens. We have screened a sample of Drosophila genes to identify those evolving under positive selection. First, we identified rapidly evolving immunity genes by comparing 140 loci in Drosophila erecta and D. yakuba. Secondly, we resequenced 23 of the fastest evolving genes from the independent species pair D. melanogaster and D. simulans, and identified those under positive selection using a McDonald-Kreitman test. There was strong evidence of adaptive evolution in two serine proteases (persephone and spirit) and a homolog of the Anopheles serpin SRPN6, and weaker evidence in another serine protease and the death domain protein dFADD. These results add to mounting evidence that immune signalling pathway molecules often evolve rapidly, possibly because they are sites of host-parasite coevolution.

  16. Novel Acoustic Loading of a Mass Spectrometer: Toward Next-Generation High-Throughput MS Screening.

    PubMed

    Sinclair, Ian; Stearns, Rick; Pringle, Steven; Wingfield, Jonathan; Datwani, Sammy; Hall, Eric; Ghislain, Luke; Majlof, Lars; Bachman, Martin

    2016-02-01

    High-throughput, direct measurement of substrate-to-product conversion by label-free detection, without the need for engineered substrates or secondary assays, could be considered the "holy grail" of drug discovery screening. Mass spectrometry (MS) has the potential to be part of this ultimate screening solution, but is constrained by the limitations of existing MS sample introduction modes that cannot meet the throughput requirements of high-throughput screening (HTS). Here we report data from a prototype system (Echo-MS) that uses acoustic droplet ejection (ADE) to transfer femtoliter-scale droplets in a rapid, precise, and accurate fashion directly into the MS. The acoustic source can load samples into the MS from a microtiter plate at a rate of up to three samples per second. The resulting MS signal displays a very sharp attack profile and ions are detected within 50 ms of activation of the acoustic transducer. Additionally, we show that the system is capable of generating multiply charged ion species from simple peptides and large proteins. The combination of high speed and low sample volume has significant potential within not only drug discovery, but also other areas of the industry. © 2015 Society for Laboratory Automation and Screening.

  17. Genetic screens in human cells using the CRISPR-Cas9 system.

    PubMed

    Wang, Tim; Wei, Jenny J; Sabatini, David M; Lander, Eric S

    2014-01-03

    The bacterial clustered regularly interspaced short palindromic repeats (CRISPR)-Cas9 system for genome editing has greatly expanded the toolbox for mammalian genetics, enabling the rapid generation of isogenic cell lines and mice with modified alleles. Here, we describe a pooled, loss-of-function genetic screening approach suitable for both positive and negative selection that uses a genome-scale lentiviral single-guide RNA (sgRNA) library. sgRNA expression cassettes were stably integrated into the genome, which enabled a complex mutant pool to be tracked by massively parallel sequencing. We used a library containing 73,000 sgRNAs to generate knockout collections and performed screens in two human cell lines. A screen for resistance to the nucleotide analog 6-thioguanine identified all expected members of the DNA mismatch repair pathway, whereas another for the DNA topoisomerase II (TOP2A) poison etoposide identified TOP2A, as expected, and also cyclin-dependent kinase 6, CDK6. A negative selection screen for essential genes identified numerous gene sets corresponding to fundamental processes. Last, we show that sgRNA efficiency is associated with specific sequence motifs, enabling the prediction of more effective sgRNAs. Collectively, these results establish Cas9/sgRNA screens as a powerful tool for systematic genetic analysis in mammalian cells.

  18. Rapid Profile: A Second Language Screening Procedure.

    ERIC Educational Resources Information Center

    Mackey, Alison; And Others

    1991-01-01

    Rapid Profile, developed by Manfred Pienemann of National Languages Institute of Australia/Language Acquisition Research Centre, is a computer-based procedure for screening speech samples collected from language learners to assess their level of language development as compared to standard patterns in the acquisition of the target language. Rapid…

  19. Orthogonal identification of gunshot residue with complementary detection principles of voltammetry, scanning electron microscopy, and energy-dispersive X-ray spectroscopy: sample, screen, and confirm.

    PubMed

    O'Mahony, Aoife M; Samek, Izabela A; Sattayasamitsathit, Sirilak; Wang, Joseph

    2014-08-19

    Field-deployable voltammetric screening coupled with complementary laboratory-based analysis to confirm the presence of gunshot residue (GSR) from the hands of a subject who has handled, loaded, or discharged a firearm is described. This protocol implements the orthogonal identification of the presence of GSR utilizing square-wave stripping voltammetry (SWSV) as a rapid screening tool along with scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) to confirm the presence of the characteristic morphology and metal composition of GSR particles. This is achieved through the judicious modification of the working electrode of a carbon screen-printed electrode (CSPE) with carbon tape (used in SEM analysis) to fix and retain a sample. A comparison between a subject who has handled and loaded a firearm and a subject who has had no contact with GSR shows the significant variations in voltammetric signals and the presence or absence of GSR-consistent particles and constituent metals. This initial electrochemical screening has no effect on the integrity of the metallic particles, and SEM/EDX analysis conducted prior to and postvoltammetry show no differences in analytical output. The carbon tape is instrumental in retaining the GSR sample after electrochemical analysis, supported by comparison with orthogonal detection at a bare CSPE. This protocol shows great promise as a two-tier detection system for the presence of GSR from the hands of a subject, whereby initial screening can be conducted rapidly onsite by minimally trained operators; confirmation can follow at the same substrate to substantiate the voltammetric results.

  20. The Rapid Forensic Evaluation of Microbes in Biodefense Research Program Will Develop a Rapid Screening and Detection System for Multiple Bio-Threat (BT) Agents for the Department of Defense

    DTIC Science & Technology

    2012-05-31

    The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing...comments regarding this burden estimate or any other aspect of this collection of information, including suggesstions for reducing this burden, to... stratification near or close to the tip of the fungal mycelium suggesting active protein and lipid synthesis. The device uses a DSLR camera with a 1-5x Macro

  1. Rapid and systemic accumulation of chloroplast mRNA-binding protein transcripts after flame stimulus in tomato

    NASA Technical Reports Server (NTRS)

    Vian, A.; Henry-Vian, C.; Davies, E.

    1999-01-01

    It has been shown that tomato (Lycopersicon esculentum) plants respond to flame wounding and electrical stimulation by a rapid (15 min) and systemic up-regulation of proteinase inhibitor (pin) genes. To find other genes having a similar expression pattern, we used subtractive cDNA screening between flamed and control plants to select clones up-regulated by flame wounding. We report the characterization of one of them, a chloroplast mRNA-binding protein encoded by a single gene and expressed preferentially in the leaves. Systemic gene expression in response to flaming in the youngest terminal leaf exhibited three distinct phases: a rapid and transient increase (5-15 min) in transcript accumulation, a decline to basal levels (15-45 min), and then a second, more prolonged increase (60-90 min). In contrast, after a mechanical wound the rapid, transient increase (5 min) was followed by a rapid decline to basal levels but no later, prolonged accumulation. In the petiole, the initial flame-wound-evoked transient increase (15 min) was followed by a continuous decline for 3 h. The nature of the wound signal(s) causing such rapid changes in transcript abundance is discussed in relation to electrical signaling, which has recently been implicated in plant responses to wounding.

  2. Rapid screening of bioactive compounds from natural products by integrating 5-channel parallel chromatography coupled with on-line mass spectrometry and microplate based assays.

    PubMed

    Zhang, Yufeng; Xiao, Shun; Sun, Lijuan; Ge, Zhiwei; Fang, Fengkai; Zhang, Wen; Wang, Yi; Cheng, Yiyu

    2013-05-13

    A high throughput method was developed for rapid screening and identification of bioactive compounds from traditional Chinese medicine, marine products and other natural products. The system, integrated with five-channel chromatographic separation and dual UV-MS detection, is compatible with in vitro 96-well microplate based bioassays. The stability and applicability of the proposed method was validated by testing radical scavenging capability of a mixture of seven known compounds (rutin, dihydroquercetin, salvianolic acid A, salvianolic acid B, glycyrrhizic acid, rubescensin A and tangeretin). Moreover, the proposed method was successfully applied to the crude extracts of traditional Chinese medicine and a marine sponge from which 12 bioactive compounds were screened and characterized based on their anti-oxidative or anti-tumor activities. In particular, two diterpenoid derivatives, agelasine B and (-)-agelasine D, were identified for the first time as anti-tumor compounds from the sponge Agelas mauritiana, showing a considerable activity toward MCF-7 cells (IC50 values of 7.84±0.65 and 10.48±0.84 μM, respectively). Our findings suggested that the integrated system of 5-channel parallel chromatography coupled with on-line mass spectrometry and microplate based assays can be a versatile and high efficient approach for the discovery of active compounds from natural products. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Navy Fuel Composition and Screening Tool (FCAST) v.2.5

    DTIC Science & Technology

    2014-07-18

    a major impediment to certification of these fuels as Fit-For- Purpose (FFP) for the U.S. Navy. A method whereby a candidate fuel could be rapidly...the U.S. Navy. A method whereby a candidate fuel could be rapidly screened for many FFP properties, using a minimal volume (< 1 mL), would overcome...mobility fuels with new alternative fuels, regardless of their source or processing methods . The Fuel Composition and Screening Tool (FCAST) was

  4. Ion channel pharmacology under flow: automation via well-plate microfluidics.

    PubMed

    Spencer, C Ian; Li, Nianzhen; Chen, Qin; Johnson, Juliette; Nevill, Tanner; Kammonen, Juha; Ionescu-Zanetti, Cristian

    2012-08-01

    Automated patch clamping addresses the need for high-throughput screening of chemical entities that alter ion channel function. As a result, there is considerable utility in the pharmaceutical screening arena for novel platforms that can produce relevant data both rapidly and consistently. Here we present results that were obtained with an innovative microfluidic automated patch clamp system utilizing a well-plate that eliminates the necessity of internal robotic liquid handling. Continuous recording from cell ensembles, rapid solution switching, and a bench-top footprint enable a number of assay formats previously inaccessible to automated systems. An electro-pneumatic interface was employed to drive the laminar flow of solutions in a microfluidic network that delivered cells in suspension to ensemble recording sites. Whole-cell voltage clamp was applied to linear arrays of 20 cells in parallel utilizing a 64-channel voltage clamp amplifier. A number of unique assays requiring sequential compound applications separated by a second or less, such as rapid determination of the agonist EC(50) for a ligand-gated ion channel or the kinetics of desensitization recovery, are enabled by the system. In addition, the system was validated via electrophysiological characterizations of both voltage-gated and ligand-gated ion channel targets: hK(V)2.1 and human Ether-à-go-go-related gene potassium channels, hNa(V)1.7 and 1.8 sodium channels, and (α1) hGABA(A) and (α1) human nicotinic acetylcholine receptor receptors. Our results show that the voltage dependence, kinetics, and interactions of these channels with pharmacological agents were matched to reference data. The results from these IonFlux™ experiments demonstrate that the system provides high-throughput automated electrophysiology with enhanced reliability and consistency, in a user-friendly format.

  5. Protein Chips for Detection of Salmonella spp. from Enrichment Culture

    PubMed Central

    Poltronieri, Palmiro; Cimaglia, Fabio; De Lorenzis, Enrico; Chiesa, Maurizio; Mezzolla, Valeria; Reca, Ida Barbara

    2016-01-01

    Food pathogens are the cause of foodborne epidemics, therefore there is a need to detect the pathogens in food productions rapidly. A pre-enrichment culture followed by selective agar plating are standard detection methods. Molecular methods such as qPCR have provided a first rapid protocol for detection of pathogens within 24 h of enrichment culture. Biosensors also may provide a rapid tool to individuate a source of Salmonella contamination at early times of pre-enrichment culture. Forty mL of Salmonella spp. enrichment culture were processed by immunoseparation using the Pathatrix, as in AFNOR validated qPCR protocols. The Salmonella biosensor combined with immunoseparation showed a limit of detection of 100 bacteria/40 mL, with a 400 fold increase to previous results. qPCR analysis requires processing of bead-bound bacteria with lysis buffer and DNA clean up, with a limit of detection of 2 cfu/50 μL. Finally, a protein chip was developed and tested in screening and identification of 5 common pathogen species, Salmonella spp., E. coli, S. aureus, Campylobacter spp. and Listeria spp. The protein chip, with high specificity in species identification, is proposed to be integrated into a Lab-on-Chip system, for rapid and reproducible screening of Salmonella spp. and other pathogen species contaminating food productions. PMID:27110786

  6. A scalable engineering approach to improve performance of a miniaturized optical detection system for in vitro point-of-care testing

    NASA Astrophysics Data System (ADS)

    Robbins, Hannah; Hu, Sijung; Liu, Changqing

    2015-03-01

    The demand for rapid screening technologies, to be used outside of a traditional healthcare setting, has been vastly expanding. This is requiring a new engineering platform for faster and cost effective techniques to be easily adopted through forward-thinking manufacturing procedures, i.e., advanced miniaturisation and heterogeneous integration of high performance microfluidics based point-of-care testing (POCT) systems. Although there has been a considerable amount of research into POCT systems, there exist tremendous challenges and bottlenecks in the design and manufacturing in order to reach a clinical acceptability of sensitivity and selectivity, as well as smart microsystems for healthcare. The project aims to research how to enable scalable production of such complex systems through 1) advanced miniaturisation of a physical layout and opto-electronic component allocation through an optimal design; and 2) heterogeneous integration of multiplexed fluorescence detection (MFD) for in vitro POCT. Verification is being arranged through experimental testing with a series of dilutions of commonly used fluorescence dye, i.e. Cy5. Iterative procedures will be engaged until satisfaction of the detection limit, of Cy5 dye, 1.209x10-10 M. The research creates a new avenue of rapid screening POCT manufacturing solutions with a particular view on high performance and multifunctional detection systems not only in POCT, but also life sciences and environmental applications.

  7. Rapid Screening Assay for the Detection of Nivalenol and Deoxynivalenol using Monoclonal Antibody and Surface Plasmon Resonance

    USDA-ARS?s Scientific Manuscript database

    Nivalenol (NIV) and Deoxynivalenol (DON) are trichothecene mycotoxins produced by Fusarium spp that contaminate mainly cereal crops, such as wheat, barley, and maize. These mycotoxins are serious health hazards to human and domestic animals. The study reports a rapid screening method of NIV and DO...

  8. Operational Art and the Incident Command System: Public Health’s Bridge in Bioterrorism Preparedness and Response

    DTIC Science & Technology

    2003-03-22

    e.g., tuberculosis screening or a maximal treadmill test ); and 3) tertiary prevention limits disability and rehabilitation where the disease or injury...major city/county laboratories to develop the capacity to conduct rapid and accurate diagnostic and reference testing for select biologic agents likely...system, but it has not been thoroughly tested and coordinated in the civilian sector. The association of mass casualty care with hospital

  9. Rapid screening and identification of antioxidants in the leaves of Malus hupehensis using off-line two-dimensional HPLC-UV-MS/MS coupled with a 1,1'-diphenyl-2-picrylhydrazyl assay.

    PubMed

    Liu, Minzhuo; Huang, Xueqian; Liu, Qi; Chen, Miao; Liao, Sen; Zhu, Fawei; Shi, Shuyun; Yang, Hua; Chen, Xiaoqing

    2018-04-17

    The leaves of Malus hupehensis have a strong antioxidant activity and are commonly consumed as a healthy tea. However, detailed information about its antioxidants is incomplete. Herein, we developed an effective strategy based on combining off-line two-dimensional high-performance liquid chromatography with ultraviolet and tandem mass spectrometry detection with a 1,1'-diphenyl-2-picrylhydrazyl assay to rapidly screen and identify the antioxidants from the leaves of M. hupehensis. In the orthogonal two-dimensional liquid chromatography system, a Venusil HILIC column was used for the first dimension, while a Universil XB-C 18 column was installed in the second dimension. As a result, 32 antioxidants, including ten dihydrochalcones, two flavanones, nine flavonols, four flavones, and seven phenolic acids were tentatively identified, out of which 23 compounds, as far as we know, were isolated and characterized from the leaves of M. hupehensis for the first time. To the best of our knowledge, this is the first systematic investigation of the antioxidants from the leaves of M. hupehensis. The results indicated that the proposed method is an efficient technique to rapidly investigate antioxidants, especially for coeluted and minor compounds in a complex system. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Newborn Bilirubin Screening for Preventing Severe Hyperbilirubinemia and Bilirubin Encephalopathy: A Rapid Review.

    PubMed

    Bhardwaj, Kalpana; Locke, Tiffany; Biringer, Anne; Booth, Allyson; Darling, Elizabeth K; Dougan, Shelley; Harrison, Jane; Hill, Stephen; Johnson, Ana; Makin, Susan; Potter, Beth; Lacaze-Masmonteil, Thierry; Little, Julian

    2017-01-01

    According to the 2004 American Academy of Pediatrics guideline on the management of hyperbilirubinemia, every newborn should be assessed for the risk of developing severe hyperbilirubinemia with the help of predischarge total serum bilirubin or transcutaneous bilirubin measurements and/or assessments of clinical risk factors. The aim of this rapid review is 1) to review the evidence for 1) predicting and preventing severe hyperbilirubinemia and bilirubin encephalopathy, 2) determining the efficacy of home/community treatments (home phototherapy) in the prevention of severe hyperbilirubinemia, and 3) non-invasive/transcutaneous methods for estimating serum bilirubin level. In this rapid review, studies were identified through the Medline database. The main outcomes of interest were severe hyperbilirubinemia and encephalopathy. A subset of articles was double screened and all articles were critically appraised using the SIGN and AMSTAR checklists. This review investigated if systems approach is likely to reduce the occurrence of severe hyperbilirubinemia. Fifty-two studies met the inclusion criteria. Included studies assessed the association between bilirubin measurement early in neonatal life and the subsequent development of severe hyperbilirubinemia and chronic bilirubin encephalopathy/kernicterus. It was observed that, highest priority should be given to (i) universal bilirubin screening programs; (ii) implementation of community and midwife practice; (iii) outreach to communities for education of prospective parents; and (iv) development of clinical pathways to monitor, evaluate and track infants with severe hyperbilirubinemia. We found substantial observational evidence that severe hyperbilirubinemia can be accurately predicted and prevented through universal bilirubin screening. So far, there is no evidence of any harm. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Utility of an improved model of amyloid-beta (Aβ1-42) toxicity in Caenorhabditis elegans for drug screening for Alzheimer’s disease

    PubMed Central

    2012-01-01

    Background The definitive indicator of Alzheimer’s disease (AD) pathology is the profuse accumulation of amyloid-ß (Aß) within the brain. Various in vitro and cell-based models have been proposed for high throughput drug screening for potential therapeutic benefit in diseases of protein misfolding. Caenorhabditis elegans offers a convenient in vivo system for examination of Aß accumulation and toxicity in a complex multicellular organism. Ease of culturing and a short life cycle make this animal model well suited to rapid screening of candidate compounds. Results We have generated a new transgenic strain of C. elegans that expresses full length Aß1-42. This strain differs from existing Aß models that predominantly express amino-truncated Aß3-42. The Aß1-42 is expressed in body wall muscle cells, where it oligomerizes, aggregates and results in severe, and fully penetrant, age progressive-paralysis. The in vivo accumulation of Aß1-42 also stains positive for amyloid dyes, consistent with in vivo fibril formation. The utility of this model for identification of potential protective compounds was examined using the investigational Alzheimer’s therapeutic PBT2, shown to be neuroprotective in mouse models of AD and significantly improve cognition in AD patients. We observed that treatment with PBT2 provided rapid and significant protection against the Aß-induced toxicity in C. elegans. Conclusion This C. elegans model of full length Aß1-42 expression can now be adopted for use in screens to rapidly identify and assist in development of potential therapeutics and to study underlying toxic mechanism(s) of Aß. PMID:23171715

  12. Phenotype-Based Screening of Small Molecules to Modify Plant Cell Walls Using BY-2 Cells.

    PubMed

    Okubo-Kurihara, Emiko; Matsui, Minami

    2018-01-01

    The plant cell wall is an important and abundant biomass with great potential for use as a modern recyclable resource. For effective utilization of this cellulosic biomass, its ability to degrade efficiently is key point. With the aim of modifying the cell wall to allow easy decomposition, we used chemical biological technology to alter its structure. As a first step toward evaluating the chemicals in the cell wall we employed a phenotype-based approach using high-throughput screening. As the plant cell wall is essential in determining cell morphology, phenotype-based screening is particularly effective in identifying compounds that bring about alterations in the cell wall. For rapid and reproducible screening, tobacco BY-2 cell is an excellent system in which to observe cell morphology. In this chapter, we provide a detailed chemical biological methodology for studying cell morphology using tobacco BY-2 cells.

  13. Rapid tests for sexually transmitted infections (STIs): the way forward

    PubMed Central

    Peeling, R W; Holmes, K K; Mabey, D

    2006-01-01

    In the developing world, laboratory services for sexually transmitted infections (STIs) are either not available, or where limited services are available, patients may not be able to pay for or physically access those services. Despite the existence of national policy for antenatal screening to prevent congenital syphilis and substantial evidence that antenatal screening is cost‐effective, implementation of syphilis screening programmes remains unacceptably low because of lack of screening tools that can be used in primary health care settings. The World Health Organization Sexually Transmitted Diseases Diagnostics Initiative (SDI) has developed the ASSURED criteria as a benchmark to decide if tests address disease control needs: Affordable, Sensitive, Specific, User‐friendly, Rapid and robust, Equipment‐free and Deliverable to end‐users. Rapid syphilis tests that can be used with whole blood approach the ASSURED criteria and can now be deployed in areas where no previous screening has been possible. Although rapid tests for chlamydia and gonorrhoea lack sensitivity, more tests are in development. The way forward for STI diagnostics requires a continuing quest for ASSURED tests, the development of a road map for test introduction, sustainable programmes for quality assurance, and the creation of a robust infrastructure linked to HIV prevention that ensures sustainability of STI control efforts that includes viral STIs. PMID:17151023

  14. Rapid tests for sexually transmitted infections (STIs): the way forward.

    PubMed

    Peeling, R W; Holmes, K K; Mabey, D; Ronald, A

    2006-12-01

    In the developing world, laboratory services for sexually transmitted infections (STIs) are either not available, or where limited services are available, patients may not be able to pay for or physically access those services. Despite the existence of national policy for antenatal screening to prevent congenital syphilis and substantial evidence that antenatal screening is cost-effective, implementation of syphilis screening programmes remains unacceptably low because of lack of screening tools that can be used in primary health care settings. The World Health Organization Sexually Transmitted Diseases Diagnostics Initiative (SDI) has developed the ASSURED criteria as a benchmark to decide if tests address disease control needs: Affordable, Sensitive, Specific, User-friendly, Rapid and robust, Equipment-free and Deliverable to end-users. Rapid syphilis tests that can be used with whole blood approach the ASSURED criteria and can now be deployed in areas where no previous screening has been possible. Although rapid tests for chlamydia and gonorrhoea lack sensitivity, more tests are in development. The way forward for STI diagnostics requires a continuing quest for ASSURED tests, the development of a road map for test introduction, sustainable programmes for quality assurance, and the creation of a robust infrastructure linked to HIV prevention that ensures sustainability of STI control efforts that includes viral STIs.

  15. Towards an ethically sensitive implementation of non invasive prenatal screening in the global context

    PubMed Central

    Mozersky, Jessica; Ravitsky, Vardit; Rapp, Rayna; Michie, Marsha; Chandrasekharan, Subhashini; Allyse, Megan

    2017-01-01

    Cell-free DNA (cfDNA) screening is an emerging prenatal technology available in 90 countries. Despite its rapid global diffusion, there is a gap in knowledge about its implementation outside of North America and Europe including low to middle income countries. To address this, we organized an international comparative workshop to explore the ethical and social implications of the global expansion of cfDNA screening. We describe 8 key insights that arose from discussions to illustrate how bioethical discussions and normative frameworks that originate and reflect North American and European ethical priorities can be enriched by attending to the importance of local context. The utility and ethical implications of cfDNA screening are highly variable and dependent upon local healthcare systems, cultural, economic, and socio-political contexts and needs. We call for a more subtle, dynamic and contextual understanding of the international spread of cfDNA screening, which will evoke diverse challenges across different contexts. PMID:28301696

  16. Sensitive fluorimetric assays for α-glucosidase activity and inhibitor screening based on β-cyclodextrin-coated quantum dots.

    PubMed

    Liu, Si-Yao; Wang, Huan; He, Tian; Qi, Liang; Zhang, Zhi-Qi

    2016-02-01

    A fluorescence method was established for a α-glucosidase activity assay and inhibitor screening based on β-cyclodextrin-coated quantum dots. p-Nitrophenol, the hydrolysis product of the α-glucosidase reaction, could quench the fluorescence of β-cyclodextrin-coated quantum dots via an electron transfer process, leading to fluorescence turn-off, whereas the fluorescence of the system turned on in the presence of α-glucosidase inhibitors. Taking advantage of the excellent properties of quantum dots, this method provided a very simple, rapid and sensitive screening method for α-glucosidase inhibitors. Two α-glucosidase inhibitors, 2,4,6-tribromophenol and acarbose, were used to evaluate the feasibility of this screening model, and IC50 values of 24 μM and 0.55 mM were obtained respectively, which were lower than those previously reported. The method may have potential application in screening α-glucosidase inhibitors. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Patient navigation reduces time to care for patients with breast symptoms and abnormal screening mammograms.

    PubMed

    McKevitt, Elaine; Dingee, Carol; Warburton, Rebecca; Pao, Jin-Si; Brown, Carl J; Wilson, Christine; Kuusk, Urve

    2018-05-01

    Concern has been raised about delays for patients presenting with breast symptoms in Canada. Our objective was to determine if our Rapid Access Breast Clinic (RABC) improved care for patients presenting with breast symptoms compared to the traditional system (TS). A retrospective chart review tabulated demographic, surgical, pathology and radiologic information. Wait times to care were determined for patients presenting with symptomatic and screen detected breast problems. Time from presentation to surgeon evaluation was shorter in the RABC group for patients with breast symptoms (81 vs 35 days, p < .0001) and abnormal screens (72 vs 40 days, p = .092). Cancer patients with abnormal screens had shorter wait times than patients with breast symptoms in the TS (47 vs 70 days, p = .036). Coordination of imaging and clinical care reduces wait times in patients with both abnormal screening mammograms and symptomatic breast presentations and should be expanded in our province. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Spatial Control of Bacteria Using Screen Printing

    PubMed Central

    Moon, Soonhee; Fritz, Ian L.; Singer, Zakary S.

    2016-01-01

    Abstract Synthetic biology has led to advances in both our understanding and engineering of genetic circuits that affect spatial and temporal behaviors in living cells. A growing array of native and synthetic circuits such as oscillators, pattern generators, and cell–cell communication systems has been studied, which exhibit spatiotemporal properties. To better understand the design principles of these genetic circuits, there is a need for versatile and precise methods for patterning cell populations in various configurations. In this study, we develop a screen printing methodology to pattern bacteria on agar, glass, and paper surfaces. Initially, we tested three biocompatible resuspension media with appropriate rheological properties for screen printing. Using microscopy, we characterized the resolution and bleed of bacteria screen prints on agar and glass surfaces, obtaining resolutions as low as 188 μm. Next, we engineered bacterial strains producing visible chromoproteins analogous to the cyan, magenta, and yellow subtractive color system for the creation of multicolored bacteria images. Using this system, we printed distinct populations in overlapping or interlocking designs on both paper and agar substrates. These proof-of-principle experiments demonstrated how the screen printing method could be used to study microbial community interactions and pattern formation of biofilms at submillimeter length scales. Overall, our approach allows for rapid and precise prototyping of patterned bacteria species that will be useful in the understanding and engineering of spatiotemporal behaviors in microbial communities. PMID:29577061

  19. Walkthrough screening evaluation field guide. Natural phenomena hazards at Department of Energy facilities: Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eder, S.J.; Eli, M.W.; Salmon, M.W.

    1993-11-01

    The US Department of Energy (DOE) has a large inventory of existing facilities. Many of these facilities were not designed and constructed to current natural phenomena hazard (NPH) criteria. The NPH events include earthquakes, extreme winds and tornadoes, and floods. DOE Order 5480.28 establishes policy and requirements for NPH mitigation for DOE facilities. DOE is conducting a multiyear project to develop evaluation guidelines for assessing the condition and determining the need for upgrades at DOE facilities. One element of the NPH evaluation guidelines` development involves the existing systems and components at DOE facilities. This effort is described in detail inmore » a cited reference. In the interim period prior to availability of the final guidelines, DOE facilities are encouraged to implement an NPH walk through screening evaluation process by which systems and components that need attention can be rapidly identified. Guidelines for conducting the walk through screening evaluations are contained herein. The result of the NPH walk through screening evaluation should be a prioritized list of systems and components that need further action. Simple and inexpensive fixes for items identified in the walk through as marginal or inadequate should be implemented without further study. By implementing an NPH walk through screening evaluation, DOE facilities may realize significant reduction in risk from NPH in the short term.« less

  20. Simulation-based instruction of technical skills

    NASA Technical Reports Server (NTRS)

    Towne, Douglas M.; Munro, Allen

    1991-01-01

    A rapid intelligent tutoring development system (RAPIDS) was developed to facilitate the production of interactive, real-time graphical device models for use in instructing the operation and maintenance of complex systems. The tools allowed subject matter experts to produce device models by creating instances of previously defined objects and positioning them in the emerging device model. These simulation authoring functions, as well as those associated with demonstrating procedures and functional effects on the completed model, required no previous programming experience or use of frame-based instructional languages. Three large simulations were developed in RAPIDS, each involving more than a dozen screen-sized sections. Seven small, single-view applications were developed to explore the range of applicability. Three workshops were conducted to train others in the use of the authoring tools. Participants learned to employ the authoring tools in three to four days and were able to produce small working device models on the fifth day.

  1. Dentists’ Willingness to Provide Expanded HIV Screening in Oral Health Care Settings: Results From a Nationally Representative Survey

    PubMed Central

    Pereyra, Margaret; Parish, Carrigan L.; Abel, Stephen; Messinger, Shari; Singer, Richard; Kunzel, Carol; Greenberg, Barbara; Gerbert, Barbara; Glick, Michael; Metsch, Lisa R.

    2014-01-01

    Objectives. Using a nationally representative survey, we determined dentists’ willingness to provide oral rapid HIV screening in the oral health care setting. Methods. From November 2010 through November 2011, a nationally representative survey of general dentists (sampling frame obtained from American Dental Association Survey Center) examined barriers and facilitators to offering oral HIV rapid testing (n = 1802; 70.7% response). Multiple logistic regression analysis examined dentists’ willingness to conduct this screening and perceived compatibility with their professional role. Results. Agreement with the importance of annual testing for high-risk persons and familiarity with the Centers for Disease Control and Prevention’s recommendations regarding routine HIV testing were positively associated with willingness to conduct such screening. Respondents’ agreement with patients’ acceptance of HIV testing and colleagues’ improved perception of them were also positively associated with willingness. Conclusions. Oral HIV rapid testing is potentially well suited to the dental setting. Although our analysis identified many predictors of dentists’ willingness to offer screening, there are many barriers, including dentists’ perceptions of patients’ acceptance, that must be addressed before such screening is likely to be widely implemented. PMID:24625163

  2. Mechanical sieve for screening mineral samples

    NASA Technical Reports Server (NTRS)

    Otto, W. P.

    1970-01-01

    Mechanical sieve consists of three horizontal screens mounted in a vertical stack. A combination of rotation and tapping produces an even flow across the screens, dislodges trapped particles, an ensures rapid segregation of the sample.

  3. Screening of Compounds Toxicity against Human Monocytic cell line-THP-1 by Flow Cytometry

    PubMed Central

    Pick, Neora; Cameron, Scott; Arad, Dorit

    2004-01-01

    The worldwide rapid increase in bacterial resistance to numerous antibiotics requires on-going development of new drugs to enter the market. As the development of new antibiotics is lengthy and costly, early monitoring of compound's toxicity is essential in the development of novel agents. Our interest is in a rapid, simple, high throughput screening method to assess cytotoxicity induced by potential agents. Some intracellular pathogens, such as Mycobacterium tuberculosis primary site of infection is human alveolar macrophages. Thus, evaluation of candidate drugs for macrophage toxicity is crucial. Protocols for high throughput drug toxicity screening of macrophages using flow cytometry are lacking in the literature. For this application we modified a preexisting technique, propidium iodide (PI) exclusion staining and utilized it for rapid toxicity tests. Samples were prepared in 96 well plates and analyzed by flow cytometry, which allowed for rapid, inexpensive and precise assessment of compound's toxicity associated with cell death. PMID:15472722

  4. Rapid analysis and exploration of fluorescence microscopy images.

    PubMed

    Pavie, Benjamin; Rajaram, Satwik; Ouyang, Austin; Altschuler, Jason M; Steininger, Robert J; Wu, Lani F; Altschuler, Steven J

    2014-03-19

    Despite rapid advances in high-throughput microscopy, quantitative image-based assays still pose significant challenges. While a variety of specialized image analysis tools are available, most traditional image-analysis-based workflows have steep learning curves (for fine tuning of analysis parameters) and result in long turnaround times between imaging and analysis. In particular, cell segmentation, the process of identifying individual cells in an image, is a major bottleneck in this regard. Here we present an alternate, cell-segmentation-free workflow based on PhenoRipper, an open-source software platform designed for the rapid analysis and exploration of microscopy images. The pipeline presented here is optimized for immunofluorescence microscopy images of cell cultures and requires minimal user intervention. Within half an hour, PhenoRipper can analyze data from a typical 96-well experiment and generate image profiles. Users can then visually explore their data, perform quality control on their experiment, ensure response to perturbations and check reproducibility of replicates. This facilitates a rapid feedback cycle between analysis and experiment, which is crucial during assay optimization. This protocol is useful not just as a first pass analysis for quality control, but also may be used as an end-to-end solution, especially for screening. The workflow described here scales to large data sets such as those generated by high-throughput screens, and has been shown to group experimental conditions by phenotype accurately over a wide range of biological systems. The PhenoBrowser interface provides an intuitive framework to explore the phenotypic space and relate image properties to biological annotations. Taken together, the protocol described here will lower the barriers to adopting quantitative analysis of image based screens.

  5. A rapid echocardiographic screening protocol for rheumatic heart disease in Samoa: a high prevalence of advanced disease.

    PubMed

    Allen, Marvin; Allen, John; Naseri, Take; Gardner, Rebecca; Tolley, Dennis; Allen, Lori

    2017-10-01

    Echocardiography has been proposed as a method to screen children for rheumatic heart disease. The World Heart Federation has established guidelines for echocardiographic screening. In this study, we describe a rapid echocardiogram screening protocol according to the World Heart Federation guidelines in Samoa, endemic for rheumatic heart disease. We performed echocardiogram screening in schoolchildren in Samoa between 2013 and 2015. A brief screening echocardiogram was performed on all students. Children with predefined criteria suspicious for rheumatic hear diseases were referred for a more comprehensive echocardiogram. Complete echocardiograms were classified according to the World Heart Federation guidelines and severity of valve disease. Echocardiographic screening was performed on 11,434 children, with a mean age of 10.2 years; 51% of them were females. A total of 558 (4.8%) children underwent comprehensive echocardiography, including 49 students who were randomly selected as controls. Definite rheumatic heart disease was observed in 115 students (10.0 per 1000): 92 students were classified as borderline (8.0 per 1000) and 23 with CHD. Advanced disease was identified in 50 students (4.4 per 1000): 15 with severe mitral regurgitation, five with severe aortic regurgitation, 11 with mitral stenoses, and 19 with mitral and aortic valve disease. We successfully applied a rapid echocardiographic screening protocol to a large number of students over a short time period - 28 days of screening over a 3-year time period - to identify a high prevalence of rheumatic heart disease. We also reported a significantly higher rate of advanced disease compared with previously published echocardiographic screening programmes.

  6. New multiplex PCR methods for rapid screening of genetically modified organisms in foods

    PubMed Central

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products. PMID:26257724

  7. New multiplex PCR methods for rapid screening of genetically modified organisms in foods.

    PubMed

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products.

  8. A SIMPLE AND RAPID MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME OF FLIGHT MASS SPECTROMETRY METHOD TO SCREEN FISH PLASMA SAMPLES FOR ESTROGEN-RESPONSIVE BIOMARKERS

    EPA Science Inventory

    In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...

  9. Rapid Identification of Pseudallescheria and Scedosporium Strains by Using Rolling Circle Amplification

    PubMed Central

    Lackner, Michaela; Najafzadeh, Mohammad Javad; Sun, Jiufeng; Lu, Qiaoyun

    2012-01-01

    The Pseudallescheria boydii complex, comprising environmental pathogens with Scedosporium anamorphs, has recently been subdivided into five main species: Scedosporium dehoogii, S. aurantiacum, Pseudallescheria minutispora, P. apiosperma, and P. boydii, while the validity of some other taxa is being debated. Several Pseudallescheria and Scedosporium species are indicator organisms of pollution in soil and water. Scedosporium dehoogii in particular is enriched in soils contaminated by aliphatic hydrocarbons. In addition, the fungi may cause life-threatening infections involving the central nervous system in severely impaired patients. For screening purposes, rapid and economic tools for species recognition are needed. Our aim is to establish rolling circle amplification (RCA) as a screening tool for species-specific identification of Pseudallescheria and Scedosporium. With this aim, a set of padlock probes was designed on the basis of the internal transcribed spacer (ITS) region, differing by up to 13 fixed mutations. Padlock probes were unique as judged from sequence comparison by BLAST search in GenBank and in dedicated research databases at CBS (Centraalbureau voor Schimmelcultures Fungal Biodiversity Centre). RCA was applied as an in vitro tool, tested with pure DNA amplified from cultures. The species-specific padlock probes designed in this study yielded 100% specificity. The method presented here was found to be an attractive alternative to identification by restriction fragment length polymorphism (RFLP) or sequencing. The rapidity (<1 day), specificity, and low costs make RCA a promising screening tool for environmentally and clinically relevant fungi. PMID:22057865

  10. Rapid identification of Pseudallescheria and Scedosporium strains by using rolling circle amplification.

    PubMed

    Lackner, Michaela; Najafzadeh, Mohammad Javad; Sun, Jiufeng; Lu, Qiaoyun; Hoog, G Sybren de

    2012-01-01

    The Pseudallescheria boydii complex, comprising environmental pathogens with Scedosporium anamorphs, has recently been subdivided into five main species: Scedosporium dehoogii, S. aurantiacum, Pseudallescheria minutispora, P. apiosperma, and P. boydii, while the validity of some other taxa is being debated. Several Pseudallescheria and Scedosporium species are indicator organisms of pollution in soil and water. Scedosporium dehoogii in particular is enriched in soils contaminated by aliphatic hydrocarbons. In addition, the fungi may cause life-threatening infections involving the central nervous system in severely impaired patients. For screening purposes, rapid and economic tools for species recognition are needed. Our aim is to establish rolling circle amplification (RCA) as a screening tool for species-specific identification of Pseudallescheria and Scedosporium. With this aim, a set of padlock probes was designed on the basis of the internal transcribed spacer (ITS) region, differing by up to 13 fixed mutations. Padlock probes were unique as judged from sequence comparison by BLAST search in GenBank and in dedicated research databases at CBS (Centraalbureau voor Schimmelcultures Fungal Biodiversity Centre). RCA was applied as an in vitro tool, tested with pure DNA amplified from cultures. The species-specific padlock probes designed in this study yielded 100% specificity. The method presented here was found to be an attractive alternative to identification by restriction fragment length polymorphism (RFLP) or sequencing. The rapidity (<1 day), specificity, and low costs make RCA a promising screening tool for environmentally and clinically relevant fungi.

  11. Programmatic Cost Evaluation of Nontargeted Opt-Out Rapid HIV Screening in the Emergency Department

    PubMed Central

    Haukoos, Jason S.; Campbell, Jonathan D.; Conroy, Amy A.; Hopkins, Emily; Bucossi, Meggan M.; Sasson, Comilla; Al-Tayyib, Alia A.; Thrun, Mark W.

    2013-01-01

    Background The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. Methods This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. Results During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%–0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%–4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Conclusions Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED. PMID:24391706

  12. Cost-effectiveness of HIV and syphilis antenatal screening: a modeling study

    PubMed Central

    Bristow, Claire C.; Larson, Elysia; Anderson, Laura J.; Klausner, Jeffrey D.

    2016-01-01

    Objectives The World Health Organization called for the elimination of maternal-to-child transmission (MTCT) of HIV and syphilis, a harmonized approach for the improvement of health outcomes for mothers and children. Testing early in pregnancy, treating seropositive pregnant women, and preventing syphilis re-infection can prevent MTCT of HIV and syphilis. We assessed the health and economic outcomes of a dual testing strategy in a simulated cohort of 100,000 antenatal care patients in Malawi. Methods We compared four screening algorithms: (1) HIV rapid test only, (2) dual HIV and syphilis rapid tests, (3) single rapid tests for HIV and syphilis, and (4) HIV rapid and syphilis laboratory tests. We calculated the expected number of adverse pregnancy outcomes, the expected costs, and the expected newborn disability adjusted life years (DALYs) for each screening algorithm. The estimated costs and DALYs for each screening algorithm were assessed from a societal perspective using Markov progression models. Additionally, we conducted a Monte Carlo multi-way sensitivity analysis, allowing for ranges of inputs. Results Our cohort decision model predicted the lowest number of adverse pregnancy outcomes in the dual HIV and syphilis rapid test strategy. Additionally, from the societal perspective, the costs of prevention and care using a dual HIV and syphilis rapid testing strategy was both the least costly ($226.92 per pregnancy) and resulted in the fewest DALYs (116,639) per 100,000 pregnancies. In the Monte Carlo simulation the dual HIV and syphilis algorithm was always cost saving and almost always reduced disability adjusted life years (DALYs) compared to HIV testing alone. Conclusion The results of the cost-effectiveness analysis showed that a dual HIV and syphilis test was cost saving compared to all other screening strategies. Adding dual rapid testing to the existing prevention of mother-to-child HIV transmission programs in Malawi and similar countries is likely to be advantageous. PMID:26920867

  13. A 100K well screen for a muscarinic receptor using the Epic label-free system--a reflection on the benefits of the label-free approach to screening seven-transmembrane receptors.

    PubMed

    Dodgson, K; Gedge, L; Murray, D C; Coldwell, M

    2009-01-01

    Seven-transmembrane receptors (7TMRs) are a family of proteins of great interest as therapeutic targets because of their abundance on the cell surface, diverse effects in modulating cell behavior and success as a key class of drugs. We have evaluated the Epic label-free system for the purpose of identifying antagonists of the muscarinic M3 receptor. We compared the data generated from the label-free technology with data for the same compounds in a calcium flux assay. We have shown that this technology can be used for high throughput screening (HTS) of 7TMRs and as an orthogonal approach to enable rapid evaluation of HTS outputs. A number of compounds have been identified which were not found in a functional HTS measuring the output from a single pathway, which may offer new approaches to inhibiting responses through this receptor.

  14. Eye Carduino: A Car Control System using Eye Movements

    NASA Astrophysics Data System (ADS)

    Kumar, Arjun; Nagaraj, Disha; Louzardo, Joel; Hegde, Rajeshwari

    2011-12-01

    Modern automotive systems are rapidly becoming highly of transportation, but can be a web integrated media centre. This paper explains the implementation of a vehicle control defined and characterized by embedded electronics and software. With new technologies, the vehicle industry is facing new opportunities and also new challenges. Electronics have improved the performance of vehicles and at the same time, new more complex applications are introduced. Examples of high level applications include adaptive cruise control and electronic stability programs (ESP). Further, a modern vehicle does not have to be merely a means using only eye movements. The EyeWriter's native hardware and software work to return the co-ordinates of where the user is looking. These co-ordinates are then used to control the car. A centre-point is defined on the screen. The higher on the screen the user's gaze is, the faster the car will accelerate. Braking is done by looking below centre. Steering is done by looking left and right on the screen.

  15. Microfluidics‐based 3D cell culture models: Utility in novel drug discovery and delivery research

    PubMed Central

    Gupta, Nilesh; Liu, Jeffrey R.; Patel, Brijeshkumar; Solomon, Deepak E.; Vaidya, Bhuvaneshwar

    2016-01-01

    Abstract The implementation of microfluidic devices within life sciences has furthered the possibilities of both academic and industrial applications such as rapid genome sequencing, predictive drug studies, and single cell manipulation. In contrast to the preferred two‐dimensional cell‐based screening, three‐dimensional (3D) systems have more in vivo relevance as well as ability to perform as a predictive tool for the success or failure of a drug screening campaign. 3D cell culture has shown an adaptive response to the recent advancements in microfluidic technologies which has allowed better control over spheroid sizes and subsequent drug screening studies. In this review, we highlight the most significant developments in the field of microfluidic 3D culture over the past half‐decade with a special focus on their benefits and challenges down the lane. With the newer technologies emerging, implementation of microfluidic 3D culture systems into the drug discovery pipeline is right around the bend. PMID:29313007

  16. Development and evaluation of a recombinant-glycoprotein-based latex agglutination test for rabies virus antibody assessment.

    PubMed

    Jemima, Ebenezer Angel; Manoharan, Seeralan; Kumanan, Kathaperumal

    2014-08-01

    The measurement of neutralizing antibodies induced by the glycoprotein of rabies virus is indispensable for assessing the level of neutralizing antibodies in animals or humans. A rapid fluorescent focus inhibition test (RFFIT) has been approved by WHO and is the most widely used method to measure the virus-neutralizing antibody content in serum, but a rapid test system would be of great value to screen large numbers of serum samples. To develop and evaluate a latex agglutination test (LAT) for measuring rabies virus antibodies, a recombinant glycoprotein was expressed in an insect cell system and purified, and the protein was coated onto latex beads at concentrations of 0.1, 0.25, 0.5, 0.75, and 1 mg/ml to find out the optimal concentration for coating latex beads. It was found that 0.5 mg/ml of recombinant protein was optimal for coating latex beads, and this concentration was used to sensitize the latex beads for screening of dog serum samples. Grading of LAT results was done with standard reference serum with known antibody titers. A total of 228 serum samples were tested, out of which 145 samples were positive by both RFFIT and LAT, and the specificity was found to be 100 %. In RFFIT, 151 samples were positive, the sensitivity was found to be 96.03 %, and the accuracy/concordance was found to be 97.39 %. A rapid field test-a latex agglutination test (LAT)-was developed and evaluated for rabies virus antibody assessment using recombinant glycoprotein of rabies virus expressed in an insect cell system.

  17. Discovery of a drug targeting microenvironmental support for lymphoma cells by screening using patient-derived xenograft cells

    PubMed Central

    Sugimoto, Keiki; Hayakawa, Fumihiko; Shimada, Satoko; Morishita, Takanobu; Shimada, Kazuyuki; Katakai, Tomoya; Tomita, Akihiro; Kiyoi, Hitoshi; Naoe, Tomoki

    2015-01-01

    Cell lines have been used for drug discovery as useful models of cancers; however, they do not recapitulate cancers faithfully, especially in the points of rapid growth rate and microenvironment independency. Consequently, the majority of conventional anti-cancer drugs are less sensitive to slow growing cells and do not target microenvironmental support, although most primary cancer cells grow slower than cell lines and depend on microenvironmental support. Here, we developed a novel high throughput drug screening system using patient-derived xenograft (PDX) cells of lymphoma that maintained primary cancer cell phenotype more than cell lines. The library containing 2613 known pharmacologically active substance and off-patent drugs were screened by this system. We could find many compounds showing higher cytotoxicity than conventional anti-tumor drugs. Especially, pyruvinium pamoate showed the highest activity and its strong anti-tumor effect was confirmed also in vivo. We extensively investigated its mechanism of action and found that it inhibited glutathione supply from stromal cells to lymphoma cells, implying the importance of the stromal protection from oxidative stress for lymphoma cell survival and a new therapeutic strategy for lymphoma. Our system introduces a primary cancer cell phenotype into cell-based phenotype screening and sheds new light on anti-cancer drug development. PMID:26278963

  18. Micromotors to capture and destroy anthrax simulant spores.

    PubMed

    Orozco, Jahir; Pan, Guoqing; Sattayasamitsathit, Sirilak; Galarnyk, Michael; Wang, Joseph

    2015-03-07

    Towards addressing the need for detecting and eliminating biothreats, we describe a micromotor-based approach for screening, capturing, isolating and destroying anthrax simulant spores in a simple and rapid manner with minimal sample processing. The B. globilli antibody-functionalized micromotors can recognize, capture and transport B. globigii spores in environmental matrices, while showing non-interactions with excess of non-target bacteria. Efficient destruction of the anthrax simulant spores is demonstrated via the micromotor-induced mixing of a mild oxidizing solution. The new micromotor-based approach paves a way to dynamic multifunctional systems that rapidly recognize, isolate, capture and destroy biological threats.

  19. gWEGA: GPU-accelerated WEGA for molecular superposition and shape comparison.

    PubMed

    Yan, Xin; Li, Jiabo; Gu, Qiong; Xu, Jun

    2014-06-05

    Virtual screening of a large chemical library for drug lead identification requires searching/superimposing a large number of three-dimensional (3D) chemical structures. This article reports a graphic processing unit (GPU)-accelerated weighted Gaussian algorithm (gWEGA) that expedites shape or shape-feature similarity score-based virtual screening. With 86 GPU nodes (each node has one GPU card), gWEGA can screen 110 million conformations derived from an entire ZINC drug-like database with diverse antidiabetic agents as query structures within 2 s (i.e., screening more than 55 million conformations per second). The rapid screening speed was accomplished through the massive parallelization on multiple GPU nodes and rapid prescreening of 3D structures (based on their shape descriptors and pharmacophore feature compositions). Copyright © 2014 Wiley Periodicals, Inc.

  20. Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system.

    PubMed

    Yamaguchi, Nobuyasu; Tokunaga, Yusuke; Goto, Satoko; Fujii, Yudai; Banno, Fumiya; Edagawa, Akiko

    2017-06-08

    Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 10 4  cells/ml, but lower numbers of L. pneumophila cells (10 1 to 10 3  cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.

  1. Holographic deep learning for rapid optical screening of anthrax spores

    PubMed Central

    Jo, YoungJu; Park, Sangjin; Jung, JaeHwang; Yoon, Jonghee; Joo, Hosung; Kim, Min-hyeok; Kang, Suk-Jo; Choi, Myung Chul; Lee, Sang Yup; Park, YongKeun

    2017-01-01

    Establishing early warning systems for anthrax attacks is crucial in biodefense. Despite numerous studies for decades, the limited sensitivity of conventional biochemical methods essentially requires preprocessing steps and thus has limitations to be used in realistic settings of biological warfare. We present an optical method for rapid and label-free screening of Bacillus anthracis spores through the synergistic application of holographic microscopy and deep learning. A deep convolutional neural network is designed to classify holographic images of unlabeled living cells. After training, the network outperforms previous techniques in all accuracy measures, achieving single-spore sensitivity and subgenus specificity. The unique “representation learning” capability of deep learning enables direct training from raw images instead of manually extracted features. The method automatically recognizes key biological traits encoded in the images and exploits them as fingerprints. This remarkable learning ability makes the proposed method readily applicable to classifying various single cells in addition to B. anthracis, as demonstrated for the diagnosis of Listeria monocytogenes, without any modification. We believe that our strategy will make holographic microscopy more accessible to medical doctors and biomedical scientists for easy, rapid, and accurate point-of-care diagnosis of pathogens. PMID:28798957

  2. Thermal Integration of a Liquid Acquisition Device into a Cryogenic Feed System

    NASA Technical Reports Server (NTRS)

    Hastings, L. J.; Bolshinskiy, L. G.; Schunk, R. G.; Martin, A. K.; Eskridge, R. H.; Frenkel, A.; Grayson, G.; Pendleton, M. L.

    2011-01-01

    Primary objectives of this effort were to define the following: (1) Approaches for quantification of the accumulation of thermal energy within a capillary screen liquid acquisition device (LAD) for a lunar lander upper stage during periods of up to 210 days on the lunar surface, (2) techniques for mitigating heat entrapment, and (3) perform initial testing, data evaluation. The technical effort was divided into the following categories: (1) Detailed thermal modeling of the LAD/feed system interactions using both COMSOL computational fluid device and standard codes, (2) FLOW-3D modeling of bulk liquid to provide interfacing conditions for the LAD thermal modeling, (3) condensation conditioning of capillary screens to stabilize surface tension retention capability, and (4) subscale testing of an integrated LAD/feed system. Substantial progress was achieved in the following technical areas: (1) Thermal modeling and experimental approaches for evaluating integrated cryogen LAD/feed systems, at both the system and component levels, (2) reduced gravity pressure control analyses, (3) analytical modeling and testing for capillary screen conditioning using condensation and wicking, and (4) development of rapid turnaround testing techniques for evaluating LAD/feed system thermal and fluid integration. A comprehensive effort, participants included a diverse cross section of representatives from academia, contractors, and multiple Marshall Space Flight Center organizations.

  3. Femtomole-Scale High-Throughput Screening of Protein Ligands with Droplet-Based Thermal Shift Assay.

    PubMed

    Liu, Wen-Wen; Zhu, Ying; Fang, Qun

    2017-06-20

    There is a great demand to measure protein-ligand interactions in rapid and low cost way. Here, we developed a microfluidic droplet-based thermal shift assay (dTSA) system for high-throughput screening of small-molecule protein ligands. The system is composed of a nanoliter droplet array chip, a microfluidic droplet robot, and a real-time fluorescence detection system. Total 324 assays could be performed in parallel in a single chip with an 18 × 18 droplet array. The consumption of dTSA for each protein or ligand sample was only 5 nL (femtomole scale), which is significantly reduced by over 3 orders of magnitude compared with those in 96- or 384-well plate-based systems. We also observed the implementation of TSA in nanoliter droplet format could substantially improve assay precision with relative standard deviation (RSD) of 0.2% (n = 50), which can be ascribed to the enhanced thermal conduction in small volume reactors. The dTSA system was optimized by studying the effect of droplet volumes, as well as protein and fluorescent dye (SYPRO Orange) concentrations. To demonstrate its potential in drug discovery, we applied the dTSA system in screening inhibitors of human thrombin with a commercial library containing 100 different small molecule compounds, and two inhibitors were successfully identified and confirmed.

  4. Research and Development of Hazardous/Toxic Waste Analytical Screening Procedures. Available Field Methods for Rapid Screening of Hazardous Waste Materials at Waste Sites (Class A Poisons).

    DTIC Science & Technology

    1982-01-01

    bromide is listed as a positive interference. Nitric oxide and nitrogen dioxide can be detected by using the Draeger nitrous fumes detector tube. A... fumes exhibit a delay from the time of exposure to the onset of symptoms. This time delay would not be conducive for a rapid field screening test. It...Dangerous when strongly heated, emits highly toxic fumes . THRESHOLD LIMIT VALUE: No information available PHYSIOLOGICAL EFFECTS: A. Intensely irritating to

  5. Improvement of a rapid screening test for chronic granulomatous disease.

    PubMed

    Iacobini, M; Duse, M; Di Coste, A; Balducci, L

    2013-01-01

    Diagnosis of CGD is made by demonstrating absent or markedly reduced oxidase activity in stimulated neutrophils. The screening test proposed is based upon the naked eye evaluation of the reduction of NBT on a solid surface. It seems to be a useful tool for rapid and inexpensive detection of CGD patients, especially for large-scale screening purposes. The test was carried out on forty-five subjects: two males affected by CGD, three female carriers and forty healthy donors. The test confirmed the results obtained with flow cytometric and NBT assays.

  6. Real-Time Continuous Identification of Greenhouse Plant Pathogens Based on Recyclable Microfluidic Bioassay System.

    PubMed

    Qu, Xiangmeng; Li, Min; Zhang, Hongbo; Lin, Chenglie; Wang, Fei; Xiao, Mingshu; Zhou, Yi; Shi, Jiye; Aldalbahi, Ali; Pei, Hao; Chen, Hong; Li, Li

    2017-09-20

    The development of a real-time continuous analytical platform for the pathogen detection is of great scientific importance for achieving better disease control and prevention. In this work, we report a rapid and recyclable microfluidic bioassay system constructed from oligonucleotide arrays for selective and sensitive continuous identification of DNA targets of fungal pathogens. We employ the thermal denaturation method to effectively regenerate the oligonucleotide arrays for multiple sample detection, which could considerably reduce the screening effort and costs. The combination of thermal denaturation and laser-induced fluorescence detection technique enables real-time continuous identification of multiple samples (<10 min per sample). As a proof of concept, we have demonstrated that two DNA targets of fungal pathogens (Botrytis cinerea and Didymella bryoniae) can be sequentially analyzed using our rapid microfluidic bioassay system, which provides a new paradigm in the design of microfluidic bioassay system and will be valuable for chemical and biomedical analysis.

  7. Cell-Free Optogenetic Gene Expression System.

    PubMed

    Jayaraman, Premkumar; Yeoh, Jing Wui; Jayaraman, Sudhaghar; Teh, Ai Ying; Zhang, Jingyun; Poh, Chueh Loo

    2018-04-20

    Optogenetic tools provide a new and efficient way to dynamically program gene expression with unmatched spatiotemporal precision. To date, their vast potential remains untapped in the field of cell-free synthetic biology, largely due to the lack of simple and efficient light-switchable systems. Here, to bridge the gap between cell-free systems and optogenetics, we studied our previously engineered one component-based blue light-inducible Escherichia coli promoter in a cell-free environment through experimental characterization and mathematical modeling. We achieved >10-fold dynamic expression and demonstrated rapid and reversible activation of the target gene to generate oscillatory response. The deterministic model developed was able to recapitulate the system behavior and helped to provide quantitative insights to optimize dynamic response. This in vitro optogenetic approach could be a powerful new high-throughput screening technology for rapid prototyping of complex biological networks in both space and time without the need for chemical induction.

  8. Rapid lead discovery through iterative screening of one bead one compound libraries.

    PubMed

    Gao, Yu; Amar, Sabrina; Pahwa, Sonia; Fields, Gregg; Kodadek, Thomas

    2015-01-12

    Primary hits that arise from screening one bead one compound (OBOC) libraries against a target of interest rarely have high potency. However, there has been little work focused on the development of an efficient workflow for primary hit improvement. In this study, we show that by characterizing the binding constants for all of the hits that arise from a screen, structure-activity relationship (SAR) data can be obtained to inform the design of "derivative libraries" of a primary hit that can then be screened under more demanding conditions to obtain improved compounds. Here, we demonstrate the rapid improvement of a primary hit against matrix metalloproteinase-14 using this approach.

  9. Optimization and high-throughput screening of antimicrobial peptides.

    PubMed

    Blondelle, Sylvie E; Lohner, Karl

    2010-01-01

    While a well-established process for lead compound discovery in for-profit companies, high-throughput screening is becoming more popular in basic and applied research settings in academia. The development of combinatorial libraries combined with easy and less expensive access to new technologies have greatly contributed to the implementation of high-throughput screening in academic laboratories. While such techniques were earlier applied to simple assays involving single targets or based on binding affinity, they have now been extended to more complex systems such as whole cell-based assays. In particular, the urgent need for new antimicrobial compounds that would overcome the rapid rise of drug-resistant microorganisms, where multiple target assays or cell-based assays are often required, has forced scientists to focus onto high-throughput technologies. Based on their existence in natural host defense systems and their different mode of action relative to commercial antibiotics, antimicrobial peptides represent a new hope in discovering novel antibiotics against multi-resistant bacteria. The ease of generating peptide libraries in different formats has allowed a rapid adaptation of high-throughput assays to the search for novel antimicrobial peptides. Similarly, the availability nowadays of high-quantity and high-quality antimicrobial peptide data has permitted the development of predictive algorithms to facilitate the optimization process. This review summarizes the various library formats that lead to de novo antimicrobial peptide sequences as well as the latest structural knowledge and optimization processes aimed at improving the peptides selectivity.

  10. Digital microfluidic platform for multiplexing enzyme assays: implications for lysosomal storage disease screening in newborns.

    PubMed

    Sista, Ramakrishna S; Eckhardt, Allen E; Wang, Tong; Graham, Carrie; Rouse, Jeremy L; Norton, Scott M; Srinivasan, Vijay; Pollack, Michael G; Tolun, Adviye A; Bali, Deeksha; Millington, David S; Pamula, Vamsee K

    2011-10-01

    Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.

  11. Screening of HIV-1 Protease Using a Combination of an Ultra-High-Throughput Fluorescent-Based Assay and RapidFire Mass Spectrometry.

    PubMed

    Meng, Juncai; Lai, Ming-Tain; Munshi, Vandna; Grobler, Jay; McCauley, John; Zuck, Paul; Johnson, Eric N; Uebele, Victor N; Hermes, Jeffrey D; Adam, Gregory C

    2015-06-01

    HIV-1 protease (PR) represents one of the primary targets for developing antiviral agents for the treatment of HIV-infected patients. To identify novel PR inhibitors, a label-free, high-throughput mass spectrometry (HTMS) assay was developed using the RapidFire platform and applied as an orthogonal assay to confirm hits identified in a fluorescence resonance energy transfer (FRET)-based primary screen of > 1 million compounds. For substrate selection, a panel of peptide substrates derived from natural processing sites for PR was evaluated on the RapidFire platform. As a result, KVSLNFPIL, a new substrate measured to have a ~ 20- and 60-fold improvement in k cat/K m over the frequently used sequences SQNYPIVQ and SQNYPIV, respectively, was identified for the HTMS screen. About 17% of hits from the FRET-based primary screen were confirmed in the HTMS confirmatory assay including all 304 known PR inhibitors in the set, demonstrating that the HTMS assay is effective at triaging false-positives while capturing true hits. Hence, with a sampling rate of ~7 s per well, the RapidFire HTMS assay enables the high-throughput evaluation of peptide substrates and functions as an efficient tool for hits triage in the discovery of novel PR inhibitors. © 2015 Society for Laboratory Automation and Screening.

  12. The rapid formation of functional monolayers on silicon under mild conditions.

    PubMed

    Ciampi, Simone; Luais, Erwann; James, Michael; Choudhury, Moinul H; Darwish, Nadim A; Gooding, J Justin

    2014-05-07

    We report on an exceedingly mild chemical functionalization of hydrogen-terminated Si(100) with unactivated and unprotected bifunctional α,ω-dialkynes. Monolayer formation occurs rapidly in the dark, and at room temperature, from dilute solutions of an aromatic-conjugated acetylene. The method addresses the poor reactivity of p-type substrates under mild conditions. We suggest the importance of several factors, including an optimal orientation for electron transfer between the adsorbate and the Si surface, conjugation of the acetylenic function with a π-system, as well as the choice of a solvent system that favors electron transfer and screens Coulombic interactions between surface holes and electrons. The passivated Si(100) electrode is amenable to further functionalization and shown to be a viable model system for redox studies at non-oxide semiconductor electrodes in aqueous solutions.

  13. Population screening for coeliac disease in primary care by district nurses using a rapid antibody test: diagnostic accuracy and feasibility study

    PubMed Central

    2007-01-01

    Objective To evaluate the feasibility and diagnostic accuracy of screening for coeliac disease by rapid detection of IgA antibodies to tissue transglutaminase performed in primary care. Design District nurses screened 6 year old children using rapid antibody testing of finger prick blood. They also collected capillary blood samples for laboratory determination of IgA and IgG antibodies to endomysium and IgA antibodies to tissue transglutaminase. Children with positive rapid test results were directly sent for biopsy of the small intestine. Setting Primary care in Jász-Nagykun-Szolnok county, Hungary. Participants 2690 children (77% of 6 year olds living in the county) and 120 nurses. Main outcome measures Positivity for antibodies to endomysium or transglutaminase in the laboratory and coeliac disease confirmed at biopsy. Results 37 children (1.4%, 95% confidence interval 0.9% to 1.8%) had biopsy confirmed coeliac disease. Only five of these children had been diagnosed clinically before screening. Rapid testing had a 78.1% sensitivity (70.0% to 89.3%) and 100% specificity (88.4% to 100%) for a final diagnosis of coeliac disease by biopsy. Sensitivity was 65.1% (50.2% to 77.6%) and specificity was 100% (99.8% to 100%) compared with combined results of IgA and IgG laboratory tests. Trained laboratory workers detected 30 of the 31 newly diagnosed IgA competent patients with the rapid test kit used blindly. Median time to biopsy after a positive rapid test result was significantly shorter (20 days, range 4-148) than after a positive laboratory result (142 days, 70-256; P<0.001). Children with coeliac disease detected at screening were smaller and had worse health status than their peers but they improved on a gluten-free diet. Conclusions A simple rapid antibody test enabled primary care nurses to detect patients with coeliac disease in the community who were not picked up in clinical care. Extra training is needed to improve sensitivity. PMID:18063612

  14. Low cost automated whole smear microscopy screening system for detection of acid fast bacilli.

    PubMed

    Law, Yan Nei; Jian, Hanbin; Lo, Norman W S; Ip, Margaret; Chan, Mia Mei Yuk; Kam, Kai Man; Wu, Xiaohua

    2018-01-01

    In countries with high tuberculosis (TB) burden, there is urgent need for rapid, large-scale screening to detect smear-positive patients. We developed a computer-aided whole smear screening system that focuses in real-time, captures images and provides diagnostic grading, for both bright-field and fluorescence microscopy for detection of acid-fast-bacilli (AFB) from respiratory specimens. To evaluate the performance of dual-mode screening system in AFB diagnostic algorithms on concentrated smears with auramine O (AO) staining, as well as direct smears with AO and Ziehl-Neelsen (ZN) staining, using mycobacterial culture results as gold standard. Adult patient sputum samples requesting for M. tuberculosis cultures were divided into three batches for staining: direct AO-stained, direct ZN-stained and concentrated smears AO-stained. All slides were graded by an experienced microscopist, in parallel with the automated whole smear screening system. Sensitivity and specificity of a TB diagnostic algorithm in using the screening system alone, and in combination with a microscopist, were evaluated. Of 488 direct AO-stained smears, 228 were culture positive. These yielded a sensitivity of 81.6% and specificity of 74.2%. Of 334 direct smears with ZN staining, 142 were culture positive, which gave a sensitivity of 70.4% and specificity of 76.6%. Of 505 concentrated smears with AO staining, 250 were culture positive, giving a sensitivity of 86.4% and specificity of 71.0%. To further improve performance, machine grading was confirmed by manual smear grading when the number of AFBs detected fell within an uncertainty range. These combined results gave significant improvement in specificity (AO-direct:85.4%; ZN-direct:85.4%; AO-concentrated:92.5%) and slight improvement in sensitivity while requiring only limited manual workload. Our system achieved high sensitivity without substantially compromising specificity when compared to culture results. Significant improvement in specificity was obtained when uncertain results were confirmed by manual smear grading. This approach had potential to substantially reduce workload of microscopists in high burden countries.

  15. Convenient, Sensitive and High-Throughput Method for Screening Botanic Origin

    NASA Astrophysics Data System (ADS)

    Yuan, Yuan; Jiang, Chao; Liu, Libing; Yu, Shulin; Cui, Zhanhu; Chen, Min; Lin, Shufang; Wang, Shu; Huang, Luqi

    2014-06-01

    In this work, a rapid (within 4-5 h), sensitive and visible new method for assessing botanic origin is developed by combining loop-mediated isothermal amplification with cationic conjugated polymers. The two Chinese medicinal materials (Jin-Yin-Hua and Shan-Yin-Hua) with similar morphology and chemical composition were clearly distinguished by gene SNP genotyping assays. The identification of plant species in Patented Chinese drugs containing Lonicera buds is successfully performed using this detection system. The method is also robust enough to be used in high-throughput screening. This new method is very helpful to identify herbal materials, and is beneficial for detecting safety and quality of botanic products.

  16. Macromolecular Crystallization with Microfluidic Free-Interface Diffusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Segelke, B

    2005-02-24

    Fluidigm released the Topaz 1.96 and 4.96 crystallization chips in the fall of 2004. Topaz 1.96 and 4.96 are the latest evolution of Fluidigm's microfluidics crystallization technologies that enable ultra low volume rapid screening for macromolecular crystallization. Topaz 1.96 and 4.96 are similar to each other but represent a major redesign of the Topaz system and have of substantially improved ease of automation and ease of use, improved efficiency and even further reduced amount of material needed. With the release of the new Topaz system, Fluidigm continues to set the standard in low volume crystallization screening which is having anmore » increasing impact in the field of structural genomics, and structural biology more generally. In to the future we are likely to see further optimization and increased utility of the Topaz crystallization system, but we are also likely to see further innovation and the emergence of competing technologies.« less

  17. [Rapid screening the alkaloids of poppy shell in hot pot condiment, beef noodle soup and seasoning by direct analysis in real time-tandem mass spectrometry].

    PubMed

    Zhang, Baile; Gao, Lihong; Xie, Yingshuang; Zhou, Wei; Chen, Xiaofeng; Lei, Chunni; Zhang, Huan

    2017-07-08

    A direct analysis in real time tandem mass spectrometry (DART-MS/MS) method was established for quickly screening five illegally added alkaloids of poppy shell from the hot pot condiment, beef noodle soup and seasoning. The samples were extracted and purified by acetonitrile, and then injected under the conditions of ionization temperature of 300℃, grid electrode voltage of 150 V and sampling rate of 0.8 mm/s using DART in the positive ion mode. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. The method is simple and rapid, and can meet the requirement of rapid screening and analysis of large quantities of samples.

  18. Evaluation of a Rapid Method for Screening Heat Stress Tolerance Using Three Korean Wheat (Triticum aestivum L.) Cultivars.

    PubMed

    Truong, Hai An; Jeong, Chan Young; Lee, Won Je; Lee, Byung Cheon; Chung, Namhyun; Kang, Chon-Sik; Cheong, Young-Keun; Hong, Suk-Whan; Lee, Hojoung

    2017-07-19

    Thermotolerance in plants is a topic of concern given the current trends in global warming. Here, we aimed to develop a rapid and reproducible screening method for selection of heat stress-tolerant wheat varieties to expedite the breeding process. We tested the robustness of the screen in three Korean wheat cultivars, "BackJung", "KeumKang", and "ChoKyeong". We showed that 4-day-old seedlings of "KeumKang" had the highest survival rates after a 45 °C treatment for 20 h. Moreover, the ability to retain chlorophyll and antioxidant activity was also highest in "KeumKang". The increase in malondialdehyde content in "ChoKyeong" indicated that this cultivar showed the greatest damage after heat stress. Collectively, our results showed that "KeumKang" is the most heat-tolerant cultivar of the three examined. In conclusion, the most reliable and rapid screening method in our investigation was survival rate examined at lethal temperature.

  19. A lab-on-a-chip system with integrated sample preparation and loop-mediated isothermal amplification for rapid and quantitative detection of Salmonella spp. in food samples.

    PubMed

    Sun, Yi; Quyen, Than Linh; Hung, Tran Quang; Chin, Wai Hoe; Wolff, Anders; Bang, Dang Duong

    2015-04-21

    Foodborne disease is a major public health threat worldwide. Salmonellosis, an infectious disease caused by Salmonella spp., is one of the most common foodborne diseases. Isolation and identification of Salmonella by conventional bacterial culture or molecular-based methods are time consuming and usually take a few hours to days to complete. In response to the demand for rapid on line or on site detection of pathogens, in this study, we describe for the first time an eight-chamber lab-on-a-chip (LOC) system with integrated magnetic bead-based sample preparation and loop-mediated isothermal amplification (LAMP) for rapid and quantitative detection of Salmonella spp. in food samples. The whole diagnostic procedures including DNA isolation, isothermal amplification, and real-time detection were accomplished in a single chamber. Up to eight samples could be handled simultaneously and the system was capable to detect Salmonella at concentration of 50 cells per test within 40 min. The simple design, together with high level of integration, isothermal amplification, and quantitative analysis of multiple samples in short time, will greatly enhance the practical applicability of the LOC system for rapid on-site screening of Salmonella for applications in food safety control, environmental surveillance, and clinical diagnostics.

  20. Rapid screening of abused drugs by direct analysis in real time (DART) coupled to time-of-flight mass spectrometry (TOF-MS) combined with ion mobility spectrometry (IMS).

    PubMed

    Lian, Ru; Wu, Zhongping; Lv, Xiaobao; Rao, Yulan; Li, Haiyang; Li, Jinghua; Wang, Rong; Ni, Chunfang; Zhang, Yurong

    2017-10-01

    Increasing in cases involving drugs of abuse leads to heavy burden for law enforcement agencies, exacerbating demand for rapid screening technique. In this study, atmospheric pressure ionization technologies including direct analysis in real time (DART) ion source coupled to a time-of-flight mass spectrometer (DART-TOF-MS)as well asdopant-assisted positive photoionization ion mobility spectrometry (DAPP-IMS) without radioactivity were utilized together as the powerful analytical tool for the rapid screening and identification of 53 abused drugs.The limits of detection (LOD) were 0.05-2μg/mL when using DART-TOF-MS and 0.02-2μg when using DAPP-IMS which could satisfy the actual requirement in forensic science laboratory. The advantages of this method included fast response, high-throughput potential, high specificity, and minimal sample preparation. A screening library of reduced mobility (K 0 ), accurate mass of informative precursor ion ([M+H] + ) and fragment ions was established respectively by employing a bench-top DAPP-IMS and TOF-MS in-source collision induced dissociation (CID) mode. Then the standardized screening procedure was developed with criteria for the confirmation of positive result. A total of 50 seized drug samples provided by local forensic laboratory we reanalyzed to testify the utility of the method. This study suggests that a method combing DART-TOF-MS and DAPP-IMS is promising for the rapid screening and identification of abused drugs with minimal sample preparation and absence of chromatography. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Toward a generalized and high-throughput enzyme screening system based on artificial genetic circuits.

    PubMed

    Choi, Su-Lim; Rha, Eugene; Lee, Sang Jun; Kim, Haseong; Kwon, Kilkoang; Jeong, Young-Su; Rhee, Young Ha; Song, Jae Jun; Kim, Hak-Sung; Lee, Seung-Goo

    2014-03-21

    Large-scale screening of enzyme libraries is essential for the development of cost-effective biological processes, which will be indispensable for the production of sustainable biobased chemicals. Here, we introduce a genetic circuit termed the Genetic Enzyme Screening System that is highly useful for high-throughput enzyme screening from diverse microbial metagenomes. The circuit consists of two AND logics. The first AND logic, the two inputs of which are the target enzyme and its substrate, is responsible for the accumulation of a phenol compound in cell. Then, the phenol compound and its inducible transcription factor, whose activation turns on the expression of a reporter gene, interact in the other logic gate. We confirmed that an individual cell harboring this genetic circuit can present approximately a 100-fold higher cellular fluorescence than the negative control and can be easily quantified by flow cytometry depending on the amounts of phenolic derivatives. The high sensitivity of the genetic circuit enables the rapid discovery of novel enzymes from metagenomic libraries, even for genes that show marginal activities in a host system. The crucial feature of this approach is that this single system can be used to screen a variety of enzymes that produce a phenol compound from respective synthetic phenyl-substrates, including cellulase, lipase, alkaline phosphatase, tyrosine phenol-lyase, and methyl parathion hydrolase. Consequently, the highly sensitive and quantitative nature of this genetic circuit along with flow cytometry techniques could provide a widely applicable toolkit for discovering and engineering novel enzymes at a single cell level.

  2. The Role of Public Knowledge, Resources, and Innovation in Responding to the Ebola Outbreak.

    PubMed

    Goldstone, Brian J; Brown, Brandon

    2015-10-01

    Since the beginning of the recent Ebola outbreak, a sense of fear has developed among the public due to the novelty of our exposure to the virus and the ill-equipped nature of our health care systems. Media sensationalism, coupled with improper knowledge of Ebola, may have contributed to mass hysteria. Most support to tackle Ebola has been direct monetary aid. However, others are working on innovative methods to control the epidemic, including the development of rapid detection methods, experimental treatments, and a viable vaccine. Rapid screening and vaccine ideas are promising, but it is unlikely that they will be ready in the coming months. This raises the question of what other tools and technological innovation can be developed to effectively stem the spread of the outbreak. Although we hope the continued outpouring of aid and health care workers to West Africa will greatly reduce the impact of Ebola, communication, screenings, treatment, and vaccine are of central importance to stop this outbreak.

  3. Rapid screening test for detection of oxytetracycline residues in milk using lateral flow assay.

    PubMed

    Naik, Laxmana; Sharma, Rajan; Mann, Bimlesh; Lata, Kiran; Rajput, Y S; Surendra Nath, B

    2017-03-15

    A rapid, semi-quantitative lateral flow assay (LFA) was developed to screen the oxytetracycline (OTC) antibiotics residues in milk samples. In this study a competitive immuno-assay format was established. Colloidal gold nano-particles (GNP) were prepared and used as labelling material in LFA. Polyclonal antibodies were generated against OTC molecule (anti-OTC), purified and the quality was assessed by enzyme linked immuno sorbet assay. For the first time membrane components required for LFA in milk system was optimized. GNP and anti-OTC stable conjugate preparation method was standardized, and then these components were placed over the conjugate pad. OTC coupled with carrier protein was placed on test line; species specific secondary antibodies were placed on the control line of the membrane matrix. Assay was validated by spiking OTC to antibiotic free milk samples and results could be accomplished within 5min. without need of any equipment. The visual detection limit was 30ppb. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Water cooler towers and other man-made aquatic systems as environmental collection systems for agents of concern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brigmon, Robin; Kingsley, Mark T.

    An apparatus and process of using existing process water sources such as cooling towers, fountains, and waterfalls is provided in which the water sources are utilized as monitoring system for the detection of environmental agents which may be present in the environment. The process water is associated with structures and have an inherent filtering or absorbing capability available in the materials and therefore can be used as a rapid screening tool for quality and quantitative assessment of environmental agents.

  5. System for rapid biohydrogen phenotypic screening of microorganisms using a chemochromic sensor

    DOEpatents

    Seibert, Michael; Benson, David K.; Flynn, Timothy Michael

    2002-01-01

    Provided is a system for identifying a hydrogen gas producing organism. The system includes a sensor film having a first layer comprising a transition metal oxide or oxysalt and a second layer comprising a hydrogen-dissociative catalyst metal, the first and second layers having an inner and an outer surface wherein the inner surface of the second layer is deposited on the outer surface of the first layer, and a substrate adjacent to the outer surface of the second layer, the organism isolated on the substrate.

  6. Multiparametric Phenotypic Screening System for Profiling Bioactive Compounds Using Human Fetal Hippocampal Neural Stem/Progenitor Cells.

    PubMed

    Tabata, Yoshikuni; Murai, Norio; Sasaki, Takeo; Taniguchi, Sachie; Suzuki, Shuichi; Yamazaki, Kazuto; Ito, Masashi

    2015-10-01

    Stem cell research has been progressing rapidly, contributing to regenerative biology and regenerative medicine. In this field, small-molecule compounds affecting stem cell proliferation/differentiation have been explored to understand stem cell biology and support regenerative medicine. In this study, we established a multiparametric screening system to detect bioactive compounds affecting the cell fate of human neural stem/progenitor cells (NSCs/NPCs), using human fetal hippocampal NSCs/NPCs, HIP-009 cells. We examined effects of 410 compounds, which were collected based on mechanisms of action (MOAs) and chemotypes, on HIP-009's cell fate (self-renewal, neuronal and astrocytic differentiation) and morphology by automated multiparametric assays and profiled induced cellular phenotypes. We found that this screening classified compounds with the same MOAs into subgroups according to additional pharmacological effects (e.g., mammalian target of rapamycin complex 1 [mTORC1] inhibitors and mTORC1/mTORC2 dual inhibitors among mTOR inhibitors). Moreover, it identified compounds that have off-target effects under matrix analyses of MOAs and structure similarities (e.g., neurotropic effects of amitriptyline among tri- and tetracyclic compounds). Therefore, this automated, medium-throughput and multiparametric screening system is useful for finding compounds that affect the cell fate of human NSCs/NPCs for supporting regenerative medicine and to fingerprint compounds based on human stem cells' multipotency, leading to understanding of stem cell biology. © 2015 Society for Laboratory Automation and Screening.

  7. An Improved Multiplex Real-Time SYBR Green PCR Assay for Analysis of 24 Target Genes from 16 Bacterial Species in Fecal DNA Samples from Patients with Foodborne Illnesses.

    PubMed

    Kawase, Jun; Etoh, Yoshiki; Ikeda, Tetsuya; Yamaguchi, Keiji; Watahiki, Masanori; Shima, Tomoko; Kameyama, Mitsuhiro; Horikawa, Kazumi; Fukushima, Hiroshi; Goto, Ryoichi; Shirabe, Komei

    2016-05-20

    Here, we developed a new version of our original screening system (Rapid Foodborne Bacterial Screening 24; RFBS24), which can simultaneously detect 24 genes of foodborne pathogens in fecal DNA samples. This new version (RFBS24 ver. 5) detected all known stx2 subtypes, enterotoxigenic Escherichia coli (STh genotype), and Vibrio parahaemolyticus (trh2), which were not detected by the original RFBS24 assay. The detection limits of RFBS24 ver. 5 were approximately 5.6 × 10(-2)-5.6 × 10(-5) (ng DNA)/reaction, significantly lower (10- to 100-fold) than those of the original RFBS24 for the 22 target genes analyzed here. We also tested the new assay on fecal DNA samples from patients infected with Salmonella, Campylobacter, or enterohemorrhagic E. coli. The number of bacterial target genes detected by RFBS24 ver. 5 was greater than that detected by RFBS24. RFBS24 ver. 5 combined with an Ultra Clean Fecal DNA Isolation Kit showed adequate performance (sensitivity and specificity 89% and 100%, respectively, for Salmonella spp. and 100% and 83%, respectively, for Campylobacter jejuni) in terms of rapid detection of a causative pathogen during foodborne-illness outbreaks. Thus, RFBS24 ver. 5 is more useful than the previous assay system for detection of foodborne pathogens and offers quick simultaneous analysis of many targets and thus facilitates rapid dissemination of information to public health officials.

  8. Programmable Bio-Nano-Chip Systems for Serum CA125 Quantification: Towards Ovarian Cancer Diagnostics at the Point-of-Care

    PubMed Central

    Raamanathan, Archana; Simmons, Glennon W.; Christodoulides, Nicolaos; Floriano, Pierre N.; Furmaga, Wieslaw B.; Redding, Spencer W.; Lu, Karen H.; Bast, Robert C.; McDevitt, John T.

    2013-01-01

    Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, modular (Programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multi-modal and multi-marker screening approaches. In the p-BNC, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a 3-D microfluidic environment, the p-BNC operating variables (incubation times, flow rates and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (Inter- and intra-assay precision of 1.2% and 1.9% and LODs of 1.0 U/mL) was achieved on this mini-sensor ensemble. Further validation with sera of ovarian cancer patients (n=20) demonstrated excellent correlation (R2 = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics. PMID:22490510

  9. Programmable bio-nano-chip systems for serum CA125 quantification: toward ovarian cancer diagnostics at the point-of-care.

    PubMed

    Raamanathan, Archana; Simmons, Glennon W; Christodoulides, Nicolaos; Floriano, Pierre N; Furmaga, Wieslaw B; Redding, Spencer W; Lu, Karen H; Bast, Robert C; McDevitt, John T

    2012-05-01

    Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive, and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, and modular (programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multimodal and multimarker screening approaches. In the p-BNCs, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing, and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a three-dimensional microfluidic environment, the p-BNC operating variables (incubation times, flow rates, and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (inter- and intra-assay precision of 1.2% and 1.9% and limit of detection of 1.0 U/mL) was achieved on this minisensor ensemble. Furthermore, validation with sera of patients with ovarian cancer (n = 20) showed excellent correlation (R(2) = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise, and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics.

  10. A Neuron-Based Screening Platform for Optimizing Genetically-Encoded Calcium Indicators

    PubMed Central

    Schreiter, Eric R.; Hasseman, Jeremy P.; Tsegaye, Getahun; Fosque, Benjamin F.; Behnam, Reza; Shields, Brenda C.; Ramirez, Melissa; Kimmel, Bruce E.; Kerr, Rex A.; Jayaraman, Vivek; Looger, Loren L.; Svoboda, Karel; Kim, Douglas S.

    2013-01-01

    Fluorescent protein-based sensors for detecting neuronal activity have been developed largely based on non-neuronal screening systems. However, the dynamics of neuronal state variables (e.g., voltage, calcium, etc.) are typically very rapid compared to those of non-excitable cells. We developed an electrical stimulation and fluorescence imaging platform based on dissociated rat primary neuronal cultures. We describe its use in testing genetically-encoded calcium indicators (GECIs). Efficient neuronal GECI expression was achieved using lentiviruses containing a neuronal-selective gene promoter. Action potentials (APs) and thus neuronal calcium levels were quantitatively controlled by electrical field stimulation, and fluorescence images were recorded. Images were segmented to extract fluorescence signals corresponding to individual GECI-expressing neurons, which improved sensitivity over full-field measurements. We demonstrate the superiority of screening GECIs in neurons compared with solution measurements. Neuronal screening was useful for efficient identification of variants with both improved response kinetics and high signal amplitudes. This platform can be used to screen many types of sensors with cellular resolution under realistic conditions where neuronal state variables are in relevant ranges with respect to timing and amplitude. PMID:24155972

  11. Rapid screening and identification of chemical hazards in surface and drinking water using high resolution mass spectrometry and a case-control filter.

    PubMed

    Kaserzon, Sarit L; Heffernan, Amy L; Thompson, Kristie; Mueller, Jochen F; Gomez Ramos, Maria Jose

    2017-09-01

    Access to clean, safe drinking water poses a serious challenge to regulators, and requires analytical strategies capable of rapid screening and identification of potentially hazardous chemicals, specifically in situations when threats to water quality or security require rapid investigations and potential response. This study describes a fast and efficient chemical hazard screening strategy for characterising trace levels of polar organic contaminants in water matrices, based on liquid chromatography high resolution mass spectrometry with post-acquisition 'case-control' data processing. This method allowed for a rapid response time of less than 24 h for the screening of target, suspect and non-target unknown chemicals via direct injection analysis, and a second, more sensitive analysis option requiring sample pre-concentration. The method was validated by fortifying samples with a range of pesticides, pharmaceuticals and personal care products (n = 46); with >90% of target compounds positively screened in samples at 1 ng mL -1 , and 46% at 0.1 ng mL -1 when analysed via direct injection. To simulate a contamination event samples were fortified with compounds not present in the commercial library (designated 'non-target compounds'; fipronil and fenitrothion), tentatively identified at 0.2 and 1 ng mL -1 , respectively; and a compound not included in any known commercial library or public database (designated 'unknown' compounds; 8Cl - perfluorooctanesulfonic acid), at 0.8 ng mL -1 . The method was applied to two 'real-case' scenarios: (1) the assessment of drinking water safety during a high-profile event in Brisbane, Australia; and (2) to screen treated, re-circulated drinking water and pre-treated (raw) water. The validated workflow was effective for rapid prioritisation and screening of suspect and non-target potential hazards at trace levels, and could be applied to a wide range of matrices and investigations where comparison of organic contaminants between an affected and control site and or timeframe is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Transmission Dynamics, Border Entry Screening, and School Holidays during the 2009 Influenza A (H1N1) Pandemic, China

    PubMed Central

    Yu, Hongjie; Cauchemez, Simon; Donnelly, Christl A.; Zhou, Lei; Feng, Luzhao; Xiang, Nijuan; Zheng, Jiandong; Ye, Min; Huai, Yang; Liao, Qiaohong; Peng, Zhibin; Feng, Yunxia; Jiang, Hui; Yang, Weizhong; Wang, Yu; Feng, Zijian

    2012-01-01

    Pandemic influenza A (H1N1) 2009 virus spread rapidly around the world in 2009. We used multiple data sources from surveillance systems and specific investigations to characterize the transmission patterns of this virus in China during May–November 2009 and analyze the effectiveness of border entry screening and holiday-related school closures on transmission. In China, age distribution and transmission dynamic characteristics were similar to those in Northern Hemisphere temperate countries. The epidemic was focused in children, with an effective reproduction number of ≈1.2–1.3. The 8 days of national holidays in October reduced the effective reproduction number by 37% (95% credible interval 28%–45%) and increased underreporting by ≈20%–30%. Border entry screening detected at most 37% of international travel–related cases, with most (89%) persons identified as having fever at time of entry. These findings suggest that border entry screening was unlikely to have delayed spread in China by >4 days. PMID:22515989

  13. Antisolvent Recrystallization Strategy to Screen Appropriate Carriers to Stabilize Filgotinib Amorphous Solid Dispersions.

    PubMed

    Ren, Fuzheng; Sun, Hanjing; Cui, Lin; Si, Yike; Chen, Ning; Ren, Guobin; Jing, Qiufang

    2018-06-01

    Drugs in amorphous solid dispersions (ASDs) are highly dispersed in hydrophilic polymeric carriers, which also help to restrain recrystallization and stabilize the ASDs. In this study, microscopic observation after antisolvent recrystallization was developed as a rapid screening method to select appropriate polymers for the initial design filgotinib (FTN) ASDs. Using solvent evaporation, FTN ASDs with the polymers were prepared, and accelerated experimentation validated this screening method. Fourier-transform infrared spectroscopy, Raman scattering, and nuclear magnetic resonance revealed hydrogen-bonding formation in the drug-polymer binary system, which was critical for ASDs stabilization. A Flory-Huggins interaction parameter and water sorption isotherms were applied to evaluate the strength of the interaction between FTN and the polymers. The dissolution rate was also significantly improved by ASDs formulation, and the presence of the polymers exerted solubilization effects. These results suggested the efficacy of this screening method as a preliminary tool for polymer selection in ASDs design. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  14. Simultaneous screening of four epidermal growth factor receptor antagonists from Curcuma longa via cell membrane chromatography online coupled with HPLC-MS.

    PubMed

    Sun, Meng; Ma, Wei-na; Guo, Ying; Hu, Zhi-gang; He, Lang-chong

    2013-07-01

    The epidermal growth factor receptors (EGFRs) are significant targets for screening active compounds. In this work, an analytical method was established for rapid screening, separation, and identification of EGFRs antagonists from Curcuma longa. Human embryonic kidney 293 cells with a steadily high expression of EGFRs were used to prepare the cell membrane stationary phase in a cell membrane chromatography model for screening active compounds. Separation and identification of the retention chromatographic peaks was achieved by HPLC-MS. The active sites, docking extents and inhibitory effects of the active compounds were also demonstrated. The screening result found that ar-turmerone, curcumin, demethoxycurcumin, and bisdemethoxycurcumin from Curcuma longa could be active components in a similar manner to gefitinib. Biological trials showed that all of four compounds can inhibit EGFRs protein secretion and cell growth in a dose-dependent manner, and downregulate the phosphorylation of EGFRs. This analytical method demonstrated fast and effective characteristics for screening, separation and identification of the active compounds from a complex system and should be useful for drug discovery with natural medicinal herbs. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Rapid review of evaluation of interventions to improve participation in cancer screening services

    PubMed Central

    Myles, Jonathan P; Maroni, Roberta; Mohammad, Abeera

    2016-01-01

    Objective Screening participation is spread differently across populations, according to factors such as ethnicity or socioeconomic status. We here review the current evidence on effects of interventions to improve cancer screening participation, focussing in particular on effects in underserved populations. Methods We selected studies to review based on their characteristics: focussing on population screening programmes, showing a quantitative estimate of the effect of the intervention, and published since 1990. To determine eligibility for our purposes, we first reviewed titles, then abstracts, and finally the full paper. We started with a narrow search and expanded this until the search yielded eligible papers on title review which were less than 1% of the total. We classified the eligible studies by intervention type and by the cancer for which they screened, while looking to identify effects in any inequality dimension. Results The 68 papers included in our review reported on 71 intervention studies. Of the interventions, 58 had significant positive effects on increasing participation, with increase rates of the order of 2%–20% (in absolute terms). Conclusions Across different countries and health systems, a number of interventions were found more consistently to improve participation in cancer screening, including in underserved populations: pre-screening reminders, general practitioner endorsement, more personalized reminders for non-participants, and more acceptable screening tests in bowel and cervical screening. PMID:27754937

  16. Microfluidic high-throughput selection of microalgal strains with superior photosynthetic productivity using competitive phototaxis

    PubMed Central

    Kim, Jaoon Young Hwan; Kwak, Ho Seok; Sung, Young Joon; Choi, Hong Il; Hong, Min Eui; Lim, Hyun Seok; Lee, Jae-Hyeok; Lee, Sang Yup; Sim, Sang Jun

    2016-01-01

    Microalgae possess great potential as a source of sustainable energy, but the intrinsic inefficiency of photosynthesis is a major challenge to realize this potential. Photosynthetic organisms evolved phototaxis to find optimal light condition for photosynthesis. Here we report a microfluidic screening using competitive phototaxis of the model alga, Chlamydomonas reinhardtii, for rapid isolation of strains with improved photosynthetic efficiencies. We demonstrated strong relationship between phototaxis and photosynthetic efficiency by quantitative analysis of phototactic response at the single-cell level using a microfluidic system. Based on this positive relationship, we enriched the strains with improved photosynthetic efficiency by isolating cells showing fast phototactic responses from a mixture of 10,000 mutants, thereby greatly improving selection efficiency over 8 fold. Among 147 strains isolated after screening, 94.6% showed improved photoautotrophic growth over the parental strain. Two mutants showed much improved performances with up to 1.9- and 8.1-fold increases in photoautotrophic cell growth and lipid production, respectively, a substantial improvement over previous approaches. We identified candidate genes that might be responsible for fast phototactic response and improved photosynthesis, which can be useful target for further strain engineering. Our approach provides a powerful screening tool for rapid improvement of microalgal strains to enhance photosynthetic productivity. PMID:26852806

  17. Rapid and reliable detection and identification of GM events using multiplex PCR coupled with oligonucleotide microarray.

    PubMed

    Xu, Xiaodan; Li, Yingcong; Zhao, Heng; Wen, Si-yuan; Wang, Sheng-qi; Huang, Jian; Huang, Kun-lun; Luo, Yun-bo

    2005-05-18

    To devise a rapid and reliable method for the detection and identification of genetically modified (GM) events, we developed a multiplex polymerase chain reaction (PCR) coupled with a DNA microarray system simultaneously aiming at many targets in a single reaction. The system included probes for screening gene, species reference gene, specific gene, construct-specific gene, event-specific gene, and internal and negative control genes. 18S rRNA was combined with species reference genes as internal controls to assess the efficiency of all reactions and to eliminate false negatives. Two sets of the multiplex PCR system were used to amplify four and five targets, respectively. Eight different structure genes could be detected and identified simultaneously for Roundup Ready soybean in a single microarray. The microarray specificity was validated by its ability to discriminate two GM maizes Bt176 and Bt11. The advantages of this method are its high specificity and greatly reduced false-positives and -negatives. The multiplex PCR coupled with microarray technology presented here is a rapid and reliable tool for the simultaneous detection of GM organism ingredients.

  18. Implications of newborn screening for nurses.

    PubMed

    DeLuca, Jane; Zanni, Karen L; Bonhomme, Natasha; Kemper, Alex R

    2013-03-01

    Newborn screening has dramatically decreased the morbidity and mortality associated with a wide range of heritable conditions. Continuing advances in screening technology and improvements in the effectiveness of treatment are driving the rapid expansion of newborn screening programs. In this article, we review issues in newborn screening care and opportunities for nurses and nursing faculty to provide education and conduct research to improve the impact of newborn screening. This article provides (a) an overview of current newborn screening activities, including how conditions are added to newborn screening panels and how implementation occurs at state and national levels; (b) a description of current controversies and ethical considerations; (c) a description of the roles of nurses in the newborn screening process; (d) suggestions for nursing education and research; and (e) a summary of expected future developments in newborn screening, including genome sequencing. Nurses are uniquely well suited to address the educational needs and future research in newborn screening because of the role that nurses play in the provision of direct clinical care and in population-based healthcare delivery. Newborn screening is a public health approach to the identification of rare but treatable conditions in early infancy. In the United States, as in other industrialized countries, newborn screening is rapidly expanding. Nurses, nurse educators, and nurse researchers are positioned to contribute to the field of newborn screening by assuring programs are implemented safely and effectively, by facilitating education of the nursing work force, and by developing and contributing to research programs in newborn screening. © 2013 Sigma Theta Tau International.

  19. Rapid carrier screening using short tandem repeats in the phenylalanine hydroxylase gene.

    PubMed

    Shawky, R M; el-Aleem, K A; Rifaat, M M; el-Naggar, R L; Marzouk, G M

    2002-01-01

    Phenylketonuria (PKU) is an autosomal recessive genetic disorder caused by defects in the phenylalanine hydroxylase (PAH) system. Our work aimed to screen the PAH locus for the presence of potentially useful short tandem repeats (STR) as markers for carrier detection in PKU families in Egypt, and to determine the level of PAH heterozygosity within the Egyptian population. The system contains at least eight independent alleles in the Egyptian population, transmitted in a Mendelian fashion. Variations in the number of STR in the 16 families studied gave rise to polymorphisms that proved to be suitable markers for PKU carrier detection and prenatal diagnosis. The most frequent allelic fragment size in PKU patients was 246 bp (35.7%), which together with a fragment of 254 bp accounted for 60.7% of the mutant chromosomes.

  20. Talking Wheelchair

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Communication is made possible for disabled individuals by means of an electronic system, developed at Stanford University's School of Medicine, which produces highly intelligible synthesized speech. Familiarly known as the "talking wheelchair" and formally as the Versatile Portable Speech Prosthesis (VPSP). Wheelchair mounted system consists of a word processor, a video screen, a voice synthesizer and a computer program which instructs the synthesizer how to produce intelligible sounds in response to user commands. Computer's memory contains 925 words plus a number of common phrases and questions. Memory can also store several thousand other words of the user's choice. Message units are selected by operating a simple switch, joystick or keyboard. Completed message appears on the video screen, then user activates speech synthesizer, which generates a voice with a somewhat mechanical tone. With the keyboard, an experienced user can construct messages as rapidly as 30 words per minute.

  1. Harnessing biosynthesis and quantitative NMR for late stage functionalization of lead molecules: Application to the M1 positive allosteric modulator (PAM) program.

    PubMed

    Brodney, Michael A; Sharma, Raman; Lazzaro, John T; Walker, Gregory S; Scott Obach, R

    2018-06-15

    A facile method for late stage diversification of lead molecules for the M1 PAM program using biosynthesis is described. Liver microsomes from several species are screened to identify a high turnover system. Subsequent incubations using less than 1 mg of substrate generate nanomole quantities of drug metabolites that are purified, characterized by microcryoprobe NMR spectroscopy, and quantified to known concentrations to enable rapid biology testing. The late-stage diversification of lead compounds provides rapid SAR feedback to the medicinal chemistry design cycle. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Construction and In Vivo Testing of Prokaryotic Riboregulators.

    PubMed

    Green, Alexander A

    2017-01-01

    RNAs that are transcribed and self-assemble within living cells are valuable tools for regulating and organizing cellular activities. Riboregulators, in particular, have been widely used for modulating translation and transcription in response to cognate transactivating or trigger RNAs, enabling cells to evaluate logic operations and to respond to environmental cues. Herein we detail a set of methods for the rapid construction and testing of prokaryotic riboregulators in Escherichia coli. These methods enable construction of dozens of riboregulator plasmids at the same time without the use of restriction enzymes. Furthermore, they facilitate rapid screening of devices and can be applied to a variety of other self-assembling in vivo RNA systems.

  3. Screening of the binding of small molecules to proteins by desorption electrospray ionization mass spectrometry combined with protein microarray.

    PubMed

    Yao, Chenxi; Wang, Tao; Zhang, Buqing; He, Dacheng; Na, Na; Ouyang, Jin

    2015-11-01

    The interaction between bioactive small molecule ligands and proteins is one of the important research areas in proteomics. Herein, a simple and rapid method is established to screen small ligands that bind to proteins. We designed an agarose slide to immobilize different proteins. The protein microarrays were allowed to interact with different small ligands, and after washing, the microarrays were screened by desorption electrospray ionization mass spectrometry (DESI MS). This method can be applied to screen specific protein binding ligands and was shown for seven proteins and 34 known ligands for these proteins. In addition, a high-throughput screening was achieved, with the analysis requiring approximately 4 s for one sample spot. We then applied this method to determine the binding between the important protein matrix metalloproteinase-9 (MMP-9) and 88 small compounds. The molecular docking results confirmed the MS results, demonstrating that this method is suitable for the rapid and accurate screening of ligands binding to proteins. Graphical Abstract ᅟ.

  4. Inventory management and reagent supply for automated chemistry.

    PubMed

    Kuzniar, E

    1999-08-01

    Developments in automated chemistry have kept pace with developments in HTS such that hundreds of thousands of new compounds can be rapidly synthesized in the belief that the greater the number and diversity of compounds that can be screened, the more successful HTS will be. The increasing use of automation for Multiple Parallel Synthesis (MPS) and the move to automated combinatorial library production is placing an overwhelming burden on the management of reagents. Although automation has improved the efficiency of the processes involved in compound synthesis, the bottleneck has shifted to ordering, collating and preparing reagents for automated chemistry resulting in loss of time, materials and momentum. Major efficiencies have already been made in the area of compound management for high throughput screening. Most of these efficiencies have been achieved with sophisticated library management systems using advanced engineering and data handling for the storage, tracking and retrieval of millions of compounds. The Automation Partnership has already provided many of the top pharmaceutical companies with modular automated storage, preparation and retrieval systems to manage compound libraries for high throughput screening. This article describes how these systems may be implemented to solve the specific problems of inventory management and reagent supply for automated chemistry.

  5. Inhibitors of SARS-CoV Entry - Identification using an Internally-Controlled Dual Envelope Pseudovirion Assay

    PubMed Central

    Zhou, Yanchen; Agudelo, Juliet; Lu, Kai; Goetz, David H.; Hansell, Elizabeth; Chen, Yen Ting; Roush, William R.; McKerrow, James; Craik, Charles S.; Amberg, Sean M.; Simmons, Graham

    2011-01-01

    Severe acute respiratory syndrome-associated coronavirus (SARS-CoV) emerged as the causal agent of an endemic atypical pneumonia, infecting thousands of people worldwide. Although a number of promising potential vaccines and therapeutic agents for SARS-CoV have been described, no effective antiviral drug against SARS-CoV is currently available. The intricate, sequential nature of the viral entry process provides multiple valid targets for drug development. Here, we describe a rapid and safe cell-based high-throughput screening system, Dual Envelope Pseudovirion (DEP) Assay, for specifically screening inhibitors of viral entry. The assay system employs a novel dual envelope strategy, using lentiviral pseudovirions as targets whose entry is driven by the SARS-CoV Spike glycoprotein. A second, unrelated viral envelope is used as an internal control to reduce the number of false positives. As an example of the power of this assay a class of inhibitors is reported with the potential to inhibit SARS-CoV at two steps of the replication cycle, viral entry and particle assembly. This assay system can be easily adapted to screen entry inhibitors against other viruses with the careful selection of matching partner virus envelopes. PMID:21820471

  6. MacroEvoLution: A New Method for the Rapid Generation of Novel Scaffold-Diverse Macrocyclic Libraries.

    PubMed

    Saupe, Jörn; Kunz, Oliver; Haustedt, Lars Ole; Jakupovic, Sven; Mang, Christian

    2017-09-04

    Macrocycles are a structural class bearing great promise for future challenges in medicinal chemistry. Nevertheless, there are few flexible approaches for the rapid generation of structurally diverse macrocyclic compound collections. Here, an efficient method for the generation of novel macrocyclic peptide-based scaffolds is reported. The process, named here as "MacroEvoLution", is based on a cyclization screening approach that gives reliable access to novel macrocyclic architectures. Classification of building blocks into specific pools ensures that scaffolds with orthogonally addressable functionalities are generated, which can easily be used for the generation of structurally diverse compound libraries. The method grants rapid access to novel scaffolds with scalable synthesis (multi gram scale) and the introduction of further diversity at a late stage. Despite being developed for peptidic systems, the approach can easily be extended for the synthesis of systems with a decreased peptidic character. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  7. Evaluation of a rapid method to exclude the presence of certain enteric pathogens in stool specimens.

    PubMed Central

    Teti, G; Burdash, N M; Zamboni, C; Fava, C; Tomasello, F; Mastroeni, P

    1984-01-01

    A new commercial method intended to exclude the presence of Salmonella spp., Shigella spp., and Yersinia enterocolitica and to presumptively identify Salmonella isolates within 2 h after primary isolation from stool specimens was evaluated. This system is marketed in Europe as API Z and in the United States as Rapid SST. The strip consists of five pairs of cupules for the screening of five lactose-negative colonies. The first cupule of each pair detects the presence of five enzymatic activities, whereas the second serves to maintain the strain for additional testing if necessary. A total of 197 fresh isolates from stool specimens and 217 stock cultures of Salmonella spp., Shigella spp., and Yersinia enterocolitica were tested, with the API 20E system as a reference method. In the stool specimens, 77.3% of the bacteria could be excluded from further workup for the presence of these organisms within 2 h. Over 97% of the stock strains and each of three fresh Salmonella isolates tested produced a reaction pattern corresponding to a correct presumptive identification. This reaction pattern was not produced by any isolate other than the Salmonella isolates. The API Z system can be used as a screen for the presence of Salmonella and Shigella spp. and can provide an accurate presumptive identification of Salmonella isolates within 2 h after primary isolation. PMID:6394610

  8. Computational fluid dynamics (CFD) studies of a miniaturized dissolution system.

    PubMed

    Frenning, G; Ahnfelt, E; Sjögren, E; Lennernäs, H

    2017-04-15

    Dissolution testing is an important tool that has applications ranging from fundamental studies of drug-release mechanisms to quality control of the final product. The rate of release of the drug from the delivery system is known to be affected by hydrodynamics. In this study we used computational fluid dynamics to simulate and investigate the hydrodynamics in a novel miniaturized dissolution method for parenteral formulations. The dissolution method is based on a rotating disc system and uses a rotating sample reservoir which is separated from the remaining dissolution medium by a nylon screen. Sample reservoirs of two sizes were investigated (SR6 and SR8) and the hydrodynamic studies were performed at rotation rates of 100, 200 and 400rpm. The overall fluid flow was similar for all investigated cases, with a lateral upward spiraling motion and central downward motion in the form of a vortex to and through the screen. The simulations indicated that the exchange of dissolution medium between the sample reservoir and the remaining release medium was rapid for typical screens, for which almost complete mixing would be expected to occur within less than one minute at 400rpm. The local hydrodynamic conditions in the sample reservoirs depended on their size; SR8 appeared to be relatively more affected than SR6 by the resistance to liquid flow resulting from the screen. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Diagnostic methods for platelet bacteria screening: current status and developments.

    PubMed

    Störmer, Melanie; Vollmer, Tanja

    2014-02-01

    Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes.

  10. Functional Screening of Metagenome and Genome Libraries for Detection of Novel Flavonoid-Modifying Enzymes

    PubMed Central

    Rabausch, U.; Juergensen, J.; Ilmberger, N.; Böhnke, S.; Fischer, S.; Schubach, B.; Schulte, M.

    2013-01-01

    The functional detection of novel enzymes other than hydrolases from metagenomes is limited since only a very few reliable screening procedures are available that allow the rapid screening of large clone libraries. For the discovery of flavonoid-modifying enzymes in genome and metagenome clone libraries, we have developed a new screening system based on high-performance thin-layer chromatography (HPTLC). This metagenome extract thin-layer chromatography analysis (META) allows the rapid detection of glycosyltransferase (GT) and also other flavonoid-modifying activities. The developed screening method is highly sensitive, and an amount of 4 ng of modified flavonoid molecules can be detected. This novel technology was validated against a control library of 1,920 fosmid clones generated from a single Bacillus cereus isolate and then used to analyze more than 38,000 clones derived from two different metagenomic preparations. Thereby we identified two novel UDP glycosyltransferase (UGT) genes. The metagenome-derived gtfC gene encoded a 52-kDa protein, and the deduced amino acid sequence was weakly similar to sequences of putative UGTs from Fibrisoma and Dyadobacter. GtfC mediated the transfer of different hexose moieties and exhibited high activities on flavones, flavonols, flavanones, and stilbenes and also accepted isoflavones and chalcones. From the control library we identified a novel macroside glycosyltransferase (MGT) with a calculated molecular mass of 46 kDa. The deduced amino acid sequence was highly similar to sequences of MGTs from Bacillus thuringiensis. Recombinant MgtB transferred the sugar residue from UDP-glucose effectively to flavones, flavonols, isoflavones, and flavanones. Moreover, MgtB exhibited high activity on larger flavonoid molecules such as tiliroside. PMID:23686272

  11. Efficacy of Allium cepa test system for screening cytotoxicity and genotoxicity of industrial effluents originated from different industrial activities.

    PubMed

    Pathiratne, Asoka; Hemachandra, Chamini K; De Silva, Nimal

    2015-12-01

    Efficacy of Allium cepa test system for screening cytotoxicity and genotoxicity of treated effluents originated from four types of industrial activities (two textile industries, three rubber based industries, two common treatment plants of industrial zones, and two water treatment plants) was assessed. Physico-chemical parameters including the heavy metal/metalloid levels of the effluents varied depending on the industry profile, but most of the measured parameters in the effluents were within the specified tolerance limits of Sri Lankan environmental regulations for discharge of industrial effluents into inland surface waters. In the A. cepa test system, the undiluted effluents induced statistically significant root growth retardation, mitosis depression, and chromosomal aberrations in root meristematic cells in most cases in comparison to the dilution water and upstream water signifying effluent induced cytotoxicity and genotoxicity. Ethyl methane sulphonate (a mutagen, positive control) and all the effluents under 1:8 dilution significantly induced total chromosomal aberrations in root meristematic cells in comparison to the dilution water and upstream water indicating inadequacy of expected 1:8 dilutions in the receiving waters for curtailing genotoxic impacts. The results support the use of a practically feasible A. cepa test system for rapid screening of cytotoxicity and genotoxicity of diverse industrial effluents discharging into inland surface waters.

  12. eC3--a modern telecommunications matrix for cervical cancer prevention in Zambia.

    PubMed

    Parham, Groesbeck P; Mwanahamuntu, Mulindi H; Pfaendler, Krista S; Sahasrabuddhe, Vikrant V; Myung, Daniel; Mkumba, Gracilia; Kapambwe, Sharon; Mwanza, Bianca; Chibwesha, Carla; Hicks, Michael L; Stringer, Jeffrey S A

    2010-07-01

    Low physician density, undercapacitated laboratory infrastructures, and limited resources are major limitations to the development and implementation of widely accessible cervical cancer prevention programs in sub-Saharan Africa. We developed a system operated by nonphysician health providers that used widely available and affordable communication technology to create locally adaptable and sustainable public sector cervical cancer prevention program in Zambia, one of the world's poorest countries. Nurses were trained to perform visual inspection with acetic acid aided by digital cervicography using predefined criteria. Electronic digital images (cervigrams) were reviewed with patients, and distance consultation was sought as necessary. Same-visit cryotherapy or referral for further evaluation by a gynecologist was offered. The Zambian system of "electronic cervical cancer control" bypasses many of the historic barriers to the delivery of preventive health care to women in low-resource environments while facilitating monitoring, evaluation, and continued education of primary health care providers, patient education, and medical records documentation. The electronic cervical cancer control system uses appropriate technology to bridge the gap between screening and diagnosis, thereby facilitating the conduct of "screen-and-treat" programs. The inherent flexibility of the system lends itself to the integration with future infrastructures using rapid molecular human papillomavirus-based screening approaches and wireless telemedicine communications.

  13. Micromachined nanocalorimetric sensor for ultra-low-volume cell-based assays.

    PubMed

    Johannessen, Erik A; Weaver, John M R; Bourova, Lenka; Svoboda, Petr; Cobbold, Peter H; Cooper, Jonathan M

    2002-05-01

    Current strategies for cell-based screening generally focus on the development of highly specific assays, which require an understanding of the nature of the signaling molecules and cellular pathways involved. In contrast, changes in temperature of cells provides a measure of altered cellular metabolism that is not stimulus specific and hence could have widespread applications in cell-based screening of receptor agonists and antagonists, as well as in the assessment of toxicity of new lead compounds. Consequently, we have developed a micromachined nanocalorimetric biological sensor using a small number of isolated living cells integrated within a subnanoliter format, which is capable of detecting 13 nW of generated power from the cells, upon exposure to a chemical or pharmaceutical stimulus. The sensor comprises a 10-junction gold and nickel thermopile, integrated on a silicon chip which was back-etched to span a 800-nm-thick membrane of silicon nitride. The thin-film membrane, which supported the sensing junctions of the thermoelectric transducer, gave the system a temperature resolution of 0.125 mK, a low heat capacity of 1.2 nJ mK(-1), and a rapid (unfiltered) response time of 12 ms. The application of the system in ultra-low-volume cell-based assays could provide a rapid endogenous screen. It offers important additional advantages over existing methods in that it is generic in nature, it does not require the use of recombinant cell lines or of detailed assay development, and finally, it can enable the use of primary cell lines or tissue biopsies.

  14. Viral pathogen discovery

    PubMed Central

    Chiu, Charles Y

    2015-01-01

    Viral pathogen discovery is of critical importance to clinical microbiology, infectious diseases, and public health. Genomic approaches for pathogen discovery, including consensus polymerase chain reaction (PCR), microarrays, and unbiased next-generation sequencing (NGS), have the capacity to comprehensively identify novel microbes present in clinical samples. Although numerous challenges remain to be addressed, including the bioinformatics analysis and interpretation of large datasets, these technologies have been successful in rapidly identifying emerging outbreak threats, screening vaccines and other biological products for microbial contamination, and discovering novel viruses associated with both acute and chronic illnesses. Downstream studies such as genome assembly, epidemiologic screening, and a culture system or animal model of infection are necessary to establish an association of a candidate pathogen with disease. PMID:23725672

  15. Convenient, sensitive and high-throughput method for screening botanic origin.

    PubMed

    Yuan, Yuan; Jiang, Chao; Liu, Libing; Yu, Shulin; Cui, Zhanhu; Chen, Min; Lin, Shufang; Wang, Shu; Huang, Luqi

    2014-06-23

    In this work, a rapid (within 4-5 h), sensitive and visible new method for assessing botanic origin is developed by combining loop-mediated isothermal amplification with cationic conjugated polymers. The two Chinese medicinal materials (Jin-Yin-Hua and Shan-Yin-Hua) with similar morphology and chemical composition were clearly distinguished by gene SNP genotyping assays. The identification of plant species in Patented Chinese drugs containing Lonicera buds is successfully performed using this detection system. The method is also robust enough to be used in high-throughput screening. This new method is very helpful to identify herbal materials, and is beneficial for detecting safety and quality of botanic products.

  16. Rapid Screening for Deleted Form of β-thalassemia by Real-Time Quantitative PCR.

    PubMed

    Ke, Liang-Yin; Chang, Jan-Gowth; Chang, Chao-Sung; Hsieh, Li-Ling; Liu, Ta-Chih

    2017-01-01

    Thalassemia is the most common single gene disease in human beings. The prevalence rate of β-thalassemia in Taiwan is approximately 1-3%. Previously methods to reveal and diagnose severe deleted form of α- or β-thalassemia were insufficient and inappropriate for prenatal diagnosis. A real-time quantitative PCR method was set up for rapid screening of the deleted form of β-thalassemia. Our results show that ΔΔCt between deleted form of β-thalassemia and normal individuals were 1.0674 ± 0.0713. On the contrary, mutation form β-thalassemia showed no difference with normal healthy control. The HBB/CCR5 ratio for deleted form of β-thalassemia patients was 0.48, whether normal individuals and mutation form of β-thalassemia was 1.0. This RQ-PCR technique is an alternative rapid screening assay for deleted form of β-thalassemia. In addition, it could also identify undefined type. Our technique by using RQ-PCR to quantify gene copies is a reliable and time-saving method that can screen deleted form of β-thalassemia. © 2016 Wiley Periodicals, Inc.

  17. Rapid Screening of Ergot Alkaloids in Sclerotia by MALDI-TOF Mass Spectrometry.

    PubMed

    Sivagnanam, Kumaran; Komatsu, Emy; Patrick, Susan; Rampitsch, Christoph; Perreault, Hélène; Gräfenhan, Tom

    2016-07-01

    Ergot is a common disease of wheat and other cereal grains that is predominantly caused by Claviceps purpurea in the field, often affecting crop yield in addition to the environment. Infected grain can be contaminated with dark sclerotia, which contain fungal metabolites such as ergot alkaloids. The occurrence of ergot alkaloids in cereal grain is a major health concern for humans and livestock. Effective and rapid screening of these mycotoxins is crucial for producers, processors, and consumers of cereal-based food and feed grain. Established methods of ergot alkaloid screening based on LC-MS or GC-MS require laborious processes. A novel method using matrix-assisted laser desorption ionization (MALDI)-time-of-flight (TOF) MS was developed to identify four ergot alkaloids. Using dihydroxybenzoic acid as the matrix, ergosine, ergocornine, ergocryptine, and ergocristine were readily detected in individual sclerotia of C. purpurea. The accuracy of the identified ergot alkaloids was further confirmed by tandem MS analysis. MALDI-TOF MS is suitable for high-throughput screening of ergot alkaloids because it permits rapid and accurate identification, simple sample preparation, and no derivatization or chromatographic separation.

  18. SMA Diagnosis: Detection of SMN1 Deletion with Real-Time mCOP-PCR System Using Fresh Blood DNA.

    PubMed

    Niba, Emma Tabe Eko; Ar Rochmah, Mawaddah; Harahap, Nur Imma Fatimah; Awano, Hiroyuki; Morioka, Ichiro; Iijima, Kazumoto; Saito, Toshio; Saito, Kayoko; Takeuchi, Atsuko; Lai, Poh San; Bouike, Yoshihiro; Nishio, Hisahide; Shinohara, Masakazu

    2017-12-18

    Spinal muscular atrophy (SMA) is one of the most common autosomal recessive disorders. The symptoms are caused by defects of lower motor neurons in the spinal cord. More than 95% of SMA patients are homozygous for survival motor neuron 1 (SMN1) deletion. We previously developed a screening system for SMN1 deletion based on a modified competitive oligonucleotide priming-PCR (mCOP-PCR) technique using dried blood spot (DBS) on filter paper. This system is convenient for mass screening in the large population and/or first-tier diagnostic method of the patients in the remote areas. However, this system was still time-consuming and effort-taking, because it required pre-amplification procedure to avoid non-specific amplification and gel-electrophoresis to detect the presence or absence of SMN1 deletion. When the fresh blood samples are used instead of DBS, or when the gel-electrophoresis is replaced by real-time PCR, we may have a simpler and more rapid diagnostic method for SMA. To establish a simpler and more rapid diagnostic method of SMN1 deletion using fresh blood DNA. DNA samples extracted from fresh blood and stored at 4 ℃ for 1 month. The samples were assayed using a real-time mCOP-PCR system without pre-amplification procedures. DNA samples had already been genotyped by PCR-restriction fragment length polymorphism (PCR-RFLP), showing the presence or absence of SMN1 exon 7. The DNA samples were directly subjected to the mCOP-PCR step. The amplification of mCOP-PCR was monitored in a real-time PCR apparatus. The genotyping results of the real-time mCOP-PCR system using fresh blood DNA were completely matched with those of PCR-RFLP. In this real-time mCOP-PCR system using fresh blood-DNA, it took only four hours from extraction of DNA to detection of the presence or absence of SMN1 deletion, while it took more than 12 hours in PCR-RFLP. Our real-time mCOP-PCR system using fresh blood DNA was rapid and accurate, suggesting it may be useful for the first-tier diagnostic method of SMA.

  19. In vitro screening of Fe2+-chelating effect by a Fenton's reaction-luminol chemiluminescence system.

    PubMed

    Wada, Mitsuhiro; Komatsu, Hiroaki; Ikeda, Rie; Aburjai, Talal A; Alkhalil, Suleiman M; Kuroda, Naotaka; Nakashima, Kenichiro

    2014-11-01

    In vitro screening of a Fe(2+) -chelating effect using a Fenton's reaction-luminol chemiluminescence (CL) system is described. The luminescence between the reactive oxygen species generated by the Fenton's reaction and luminol was decreased on capturing Fe(2+) using a chelator. The proposed method can prevent the consumption of expensive seed compounds (drug discovery candidates) owing to the high sensitivity of CL detection. Therefore, the assay could be performed using small volumes of sample solution (150 μL) at micromolar concentrations. After optimization of the screening conditions, the efficacies of conventional chelators such as ethylenediaminetetraacetic acid (EDTA), diethylentriaminepentaacetic acid (DETAPAC), deferoxamine, deferiprone and 1,10-phenanthroline were examined. EC50 values for these compounds (except 1,10-phenanthroline) were in the range 3.20 ± 0.87 to 9.57 ± 0.64 μM (n = 3). Rapid measurement of the Fe(2+)-chelating effect with an assay run time of a few minutes could be achieved using the proposed method. In addition, the specificity of the method was discussed. Copyright © 2014 John Wiley & Sons, Ltd.

  20. A ligand predication tool based on modeling and reasoning with imprecise probabilistic knowledge.

    PubMed

    Liu, Weiru; Yue, Anbu; Timson, David J

    2010-04-01

    Ligand prediction has been driven by a fundamental desire to understand more about how biomolecules recognize their ligands and by the commercial imperative to develop new drugs. Most of the current available software systems are very complex and time-consuming to use. Therefore, developing simple and efficient tools to perform initial screening of interesting compounds is an appealing idea. In this paper, we introduce our tool for very rapid screening for likely ligands (either substrates or inhibitors) based on reasoning with imprecise probabilistic knowledge elicited from past experiments. Probabilistic knowledge is input to the system via a user-friendly interface showing a base compound structure. A prediction of whether a particular compound is a substrate is queried against the acquired probabilistic knowledge base and a probability is returned as an indication of the prediction. This tool will be particularly useful in situations where a number of similar compounds have been screened experimentally, but information is not available for all possible members of that group of compounds. We use two case studies to demonstrate how to use the tool. 2009 Elsevier Ireland Ltd. All rights reserved.

  1. Hospital Malnutrition: Prevalence, Identification and Impact on Patients and the Healthcare System

    PubMed Central

    Barker, Lisa A.; Gout, Belinda S.; Crowe, Timothy C.

    2011-01-01

    Malnutrition is a debilitating and highly prevalent condition in the acute hospital setting, with Australian and international studies reporting rates of approximately 40%. Malnutrition is associated with many adverse outcomes including depression of the immune system, impaired wound healing, muscle wasting, longer lengths of hospital stay, higher treatment costs and increased mortality. Referral rates for dietetic assessment and treatment of malnourished patients have proven to be suboptimal, thereby increasing the likelihood of developing such aforementioned complications. Nutrition risk screening using a validated tool is a simple technique to rapidly identify patients at risk of malnutrition, and provides a basis for prompt dietetic referrals. In Australia, nutrition screening upon hospital admission is not mandatory, which is of concern knowing that malnutrition remains under-reported and often poorly documented. Unidentified malnutrition not only heightens the risk of adverse complications for patients, but can potentially result in foregone reimbursements to the hospital through casemix-based funding schemes. It is strongly recommended that mandatory nutrition screening be widely adopted in line with published best-practice guidelines to effectively target and reduce the incidence of hospital malnutrition. PMID:21556200

  2. [A new system of testing visual performance based on the cylindrical lens screen].

    PubMed

    Doege, E; Krause, O

    1983-09-01

    Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.

  3. High-throughput behavioral screening method for detecting auditory response defects in zebrafish.

    PubMed

    Bang, Pascal I; Yelick, Pamela C; Malicki, Jarema J; Sewell, William F

    2002-08-30

    We have developed an automated, high-throughput behavioral screening method for detecting hearing defects in zebrafish. Our assay monitors a rapid escape reflex in response to a loud sound. With this approach, 36 adult zebrafish, restrained in visually isolated compartments, can be simultaneously assessed for responsiveness to near-field 400 Hz sinusoidal tone bursts. Automated, objective determinations of responses are achieved with a computer program that obtains images at precise times relative to the acoustic stimulus. Images taken with a CCD video camera before and after stimulus presentation are subtracted to reveal a response to the sound. Up to 108 fish can be screened per hour. Over 6500 fish were tested to validate the reliability of the assay. We found that 1% of these animals displayed hearing deficits. The phenotypes of non-responders were further assessed with radiological analysis for defects in the gross morphology of the auditory system. Nearly all of those showed abnormalities in conductive elements of the auditory system: the swim bladder or Weberian ossicles. Copyright 2002 Elsevier Science B.V.

  4. Screening and Biosensor-Based Approaches for Lung Cancer Detection

    PubMed Central

    Wang, Lulu

    2017-01-01

    Early diagnosis of lung cancer helps to reduce the cancer death rate significantly. Over the years, investigators worldwide have extensively investigated many screening modalities for lung cancer detection, including computerized tomography, chest X-ray, positron emission tomography, sputum cytology, magnetic resonance imaging and biopsy. However, these techniques are not suitable for patients with other pathologies. Developing a rapid and sensitive technique for early diagnosis of lung cancer is urgently needed. Biosensor-based techniques have been recently recommended as a rapid and cost-effective tool for early diagnosis of lung tumor markers. This paper reviews the recent development in screening and biosensor-based techniques for early lung cancer detection. PMID:29065541

  5. [The prevalence of yaws among the Aka in the Congo].

    PubMed

    Coldiron, M; Obvala, D; Mouniaman-Nara, I; Pena, J; Blondel, C; Porten, K

    2013-05-01

    This study, conducted in 2012 in two districts of the Congo (Bétou and Enyellé), screened for yaws (endemic treponemiasis) that could be treated by a single dose of azithromycin. The screening involved a clinical history, followed by a clinical examination of the children reporting dermatological problems. A rapid diagnostic test for treponema was performed on the children with suspicious lesions. Of 6215 children screened, 485 (7.8%) had such lesions; 480 (99.0%) of them had a rapid diagnostic test, and it was positive for 183 (38.1%). This so-called Morges strategy is aimed at eradicating yaws in endemic areas.

  6. An evaluation of a rapid real time polymerase chain reaction assay for detection of group B streptococcus as part of a neonatal group B streptococcus prevention strategy.

    PubMed

    Money, Deborah; Dobson, Simon; Cole, Lesley; Karacabeyli, Eda; Blondel-Hill, Edith; Milner, Ruth; Thomas, Eva

    2008-09-01

    To evaluate the sensitivity, specificity, and feasibility of a rapid real-time polymerase chain reaction (PCR) test for group B streptococcus (GBS) completed during labour, compared with the standard culture test performed at 35 to 37 weeks' gestation. Women presenting to the maternity unit for term vaginal delivery had two vaginal/rectal samples collected. One swab was tested using a rapid PCR method (IDI-Strep B, Infectio Diagnostic [IDI] Inc., Sainte-Foy QC ), and the other was cultured after enrichment (intrapartum culture). Comparisons were made between these results and those of a culture-based screen at 35 to 37 weeks' gestation. Of the 190 women enrolled, 85% had results of the standard screen at 35 to 37 weeks available for comparison. The sensitivity and specificity of the standard 35- to 37-week screen were 84.3% (95% confidence interval [CI], 71.4-93.0) and 93.2% (95% CI 86.5-97.2) respectively, whereas the sensitivity and specificity of the rapid PCR were 90.7% (95% CI 79.7-96.9) and 97.6% (95% CI 93.1-99.5), respectively. The median reporting time for the rapid PCR test was 99 minutes (range 50-255). Results were available more than four hours before delivery in 81% of cases. In this Canadian centre, a rapid PCR test done at the time of labour (IDI-Strep B) demonstrated high sensitivity and specificity, comparable to the 35- to 37-week screen. The time to reporting results was acceptably short, allowing for timely administration of intrapartum prophylactic antibiotics.

  7. A scoping review of rapid review methods.

    PubMed

    Tricco, Andrea C; Antony, Jesmin; Zarin, Wasifa; Strifler, Lisa; Ghassemi, Marco; Ivory, John; Perrier, Laure; Hutton, Brian; Moher, David; Straus, Sharon E

    2015-09-16

    Rapid reviews are a form of knowledge synthesis in which components of the systematic review process are simplified or omitted to produce information in a timely manner. Although numerous centers are conducting rapid reviews internationally, few studies have examined the methodological characteristics of rapid reviews. We aimed to examine articles, books, and reports that evaluated, compared, used or described rapid reviews or methods through a scoping review. MEDLINE, EMBASE, the Cochrane Library, internet websites of rapid review producers, and reference lists were searched to identify articles for inclusion. Two reviewers independently screened literature search results and abstracted data from included studies. Descriptive analysis was conducted. We included 100 articles plus one companion report that were published between 1997 and 2013. The studies were categorized as 84 application papers, seven development papers, six impact papers, and four comparison papers (one was included in two categories). The rapid reviews were conducted between 1 and 12 months, predominantly in Europe (58 %) and North America (20 %). The included studies failed to report 6 % to 73 % of the specific systematic review steps examined. Fifty unique rapid review methods were identified; 16 methods occurred more than once. Streamlined methods that were used in the 82 rapid reviews included limiting the literature search to published literature (24 %) or one database (2 %), limiting inclusion criteria by date (68 %) or language (49 %), having one person screen and another verify or screen excluded studies (6 %), having one person abstract data and another verify (23 %), not conducting risk of bias/quality appraisal (7 %) or having only one reviewer conduct the quality appraisal (7 %), and presenting results as a narrative summary (78 %). Four case studies were identified that compared the results of rapid reviews to systematic reviews. Three studies found that the conclusions between rapid reviews and systematic reviews were congruent. Numerous rapid review approaches were identified and few were used consistently in the literature. Poor quality of reporting was observed. A prospective study comparing the results from rapid reviews to those obtained through systematic reviews is warranted.

  8. Analysis Of Volatile Fingerprints: A Rapid Screening Method For Antifungal Agents For Efficacy Against Dermatophytes

    NASA Astrophysics Data System (ADS)

    Naraghi, Kamran; Sahgal, Natasha; Adriaans, Beverley; Barr, Hugh; Magan, Naresh

    2009-05-01

    The potential of using an electronic nose (E. nose) for rapid screening dermatophytes to antifungal agents was studied. In vitro, the 50 and 90% effective concentration (EC) values of five antifungal agents for T. rubrum and T. mentagrophytes were obtained by mycelial growth assays. Then, the qualitative volatile production patterns of the growth responses of these fungi to these values were incorporated into solid medium were analysed after 96-120 hrs incubation at 25° C using headspace analyses. Overall, results, using PCA and CA demonstrated that it is possible to differentiate between various treatments within 96-120 hrs. This study showed that potential exists for using qualitative volatile patterns as a rapid screening method for antifungal agents for microorganism. This approach could also facilitate the monitoring of antimicrobial drug activities and infection control programmes and perhaps drug resistance build up in microbial species.

  9. Rapid screening of pharmaceutical drugs using thermal desorption - SALDI mass spectrometry

    NASA Astrophysics Data System (ADS)

    Grechnikov, A. A.; Kubasov, A. E.; Georgieva, V. B.; Borodkov, A. S.; Nikiforov, S. M.; Simanovsky, Ya O.; Alimpiev, S. S.

    2012-12-01

    A novel approach to the rapid screening of pharmaceutical drugs by surface assisted laser desorption-ionization (SALDI) mass spectrometry with the rotating ball interface coupled with temperature programmed thermal desorption has been developed. Analytes were thermally desorbed and deposited onto the surface of amorphous silicon substrate attached to the rotating ball. The ball was rotated and the deposited analytes were analyzed using SALDI. The effectiveness of coupling SALDI mass spectrometry with thermal desorption was evaluated by the direct and rapid analysis of tablets containing lidocaine, diphenhydramine and propranolol without any sample pretreatment. The overall duration of the screening procedure was 30÷40 sec. Real urine samples were studied for drug analysis. It is shown that with simple preparation steps, urine samples can be quantitatively analyzed using the proposed technique with the detection limits in the range of 0.2÷0.5 ng/ml.

  10. High-Content, High-Throughput Screening for the Identification of Cytotoxic Compounds Based on Cell Morphology and Cell Proliferation Markers

    PubMed Central

    Martin, Heather L.; Adams, Matthew; Higgins, Julie; Bond, Jacquelyn; Morrison, Ewan E.; Bell, Sandra M.; Warriner, Stuart; Nelson, Adam; Tomlinson, Darren C.

    2014-01-01

    Toxicity is a major cause of failure in drug discovery and development, and whilst robust toxicological testing occurs, efficiency could be improved if compounds with cytotoxic characteristics were identified during primary compound screening. The use of high-content imaging in primary screening is becoming more widespread, and by utilising phenotypic approaches it should be possible to incorporate cytotoxicity counter-screens into primary screens. Here we present a novel phenotypic assay that can be used as a counter-screen to identify compounds with adverse cellular effects. This assay has been developed using U2OS cells, the PerkinElmer Operetta high-content/high-throughput imaging system and Columbus image analysis software. In Columbus, algorithms were devised to identify changes in nuclear morphology, cell shape and proliferation using DAPI, TOTO-3 and phosphohistone H3 staining, respectively. The algorithms were developed and tested on cells treated with doxorubicin, taxol and nocodazole. The assay was then used to screen a novel, chemical library, rich in natural product-like molecules of over 300 compounds, 13.6% of which were identified as having adverse cellular effects. This assay provides a relatively cheap and rapid approach for identifying compounds with adverse cellular effects during screening assays, potentially reducing compound rejection due to toxicity in subsequent in vitro and in vivo assays. PMID:24505478

  11. Genome-wide screening and identification of antigens for rickettsial vaccine development

    USDA-ARS?s Scientific Manuscript database

    The capacity to identify immunogens for vaccine development by genome-wide screening has been markedly enhanced by the availability of complete microbial genome sequences coupled to rapid proteomic and bioinformatic analysis. Critical to this genome-wide screening is in vivo testing in the context o...

  12. Multiplex and label-free screening of foodborne pathogens using surface plasmon resonance imaging

    USDA-ARS?s Scientific Manuscript database

    In order to protect outbreaks caused by foodborne pathogens, more rapid and efficient methods are needed for pathogen screening from food samples. Surface plasmon resonance imaging (SPRi) is an emerging optical technique, which allows for label-free screening of multiple targets simultaneously with ...

  13. DEVELOPMENT OF AN OBJECTIVE AND QUANTIFIABLE TERATOLOGICAL SCREEN FOR USE IN ZEBRAFISH LARVAE.

    EPA Science Inventory

    To address EPA’s need to prioritize large numbers of chemicals for testing, a rapid, cost-effective in vivo screen for potential developmental toxicity using an alternative vertebrate species (zebrafish;Danio rerio) has been developed. A component of that screen is the observatio...

  14. Evaluating the Impact of Uncertainties in Clearance and Exposure When Prioritizing Chemicals Screened in High-Throughput Assays

    EPA Science Inventory

    The toxicity-testing paradigm has evolved to include high-throughput (HT) methods for addressing the increasing need to screen hundreds to thousands of chemicals rapidly. Approaches that involve in vitro screening assays, in silico predictions of exposure concentrations, and phar...

  15. Application of Titration-Based Screening for the Rapid Pilot Testing of High-Throughput Assays.

    PubMed

    Zhang, Ji-Hu; Kang, Zhao B; Ardayfio, Ophelia; Ho, Pei-i; Smith, Thomas; Wallace, Iain; Bowes, Scott; Hill, W Adam; Auld, Douglas S

    2014-06-01

    Pilot testing of an assay intended for high-throughput screening (HTS) with small compound sets is a necessary but often time-consuming step in the validation of an assay protocol. When the initial testing concentration is less than optimal, this can involve iterative testing at different concentrations to further evaluate the pilot outcome, which can be even more time-consuming. Quantitative HTS (qHTS) enables flexible and rapid collection of assay performance statistics, hits at different concentrations, and concentration-response curves in a single experiment. Here we describe the qHTS process for pilot testing in which eight-point concentration-response curves are produced using an interplate asymmetric dilution protocol in which the first four concentrations are used to represent the range of typical HTS screening concentrations and the last four concentrations are added for robust curve fitting to determine potency/efficacy values. We also describe how these data can be analyzed to predict the frequency of false-positives, false-negatives, hit rates, and confirmation rates for the HTS process as a function of screening concentration. By taking into account the compound pharmacology, this pilot-testing paradigm enables rapid assessment of the assay performance and choosing the optimal concentration for the large-scale HTS in one experiment. © 2013 Society for Laboratory Automation and Screening.

  16. A rapid generation of adenovirus vector with a genetic modification in hexon protein.

    PubMed

    Di, Bingyan; Mao, Qinwen; Zhao, Junli; Li, Xing; Wang, Dongyang; Xia, Haibin

    2012-02-10

    The generation of hexon-modified adenovirus vector has proven difficult. In this paper, we developed a novel method for rapid generation of hexon-modified adenoviral vector via one step ligation in vitro followed by quick white/blue color screening. The new system has the following features. First, eGFP expression driven by the CMV promoter in E1 region functions as a reporter to evaluate the tropism of hexon-modified adenovirus in vitro. Second, it has two unique restriction enzyme sites with sticky ends located in the hexon HVR5 region. Third, a lacZ expression cassette under the control of plac promoter is placed between the two restriction enzyme sites, which allows recombinants to be selected using blue/white screening. To prove the principle of the method, genetically modified adenoviruses were successfully produced by insertion of NGR, RGD or Tat PTD peptide into hexon HVR5. Furthermore, the transduction efficiency of the Tat PTD modified virus was shown to be a significant enhancement in A172 and CHO-K1 cells. In conclusion, the novel system makes the production of truly retargeted vectors more promising, which would be of substantial benefit for cancer gene therapy. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. A multipumping flow system for in vitro screening of peroxynitrite scavengers.

    PubMed

    Ribeiro, Marta F T; Dias, Ana C B; Santos, João L M; Fernandes, Eduarda; Lima, José L F C; Zagatto, Elias A G

    2007-09-01

    Peroxynitrite anion is a reactive nitrogen species formed in vivo by the rapid, controlled diffusion reaction between nitric oxide and superoxide radicals. By reacting with several biological molecules, peroxynitrite may cause important cellular and tissue deleterious effects, which have been associated with many diseases. In this work, an automated flow-based procedure for the in vitro generation of peroxynitrite and subsequent screening of the scavenging activity of selected compounds is developed. This procedure involves a multipumping flow system (MPFS) and exploits the ability of compounds such as lipoic acid, dihydrolipoic acid, cysteine, reduced glutathione, oxidized glutathione, sulindac, and sulindac sulfone to inhibit the chemiluminescent reaction of luminol with peroxynitrite under physiological simulated conditions. Peroxynitrite was generated in the MPFS by the online reaction of acidified hydrogen peroxide with nitrite, followed by a subsequent stabilization by merging with a sodium hydroxide solution to rapidly quench the developing reaction. The pulsed flow and the timed synchronized insertion of sample and reagent solutions provided by the MPFS ensure the establishment of the reaction zone only inside the flow cell, thus allowing maximum chemiluminescence emission detection. The results obtained for the assayed compounds show that, with the exception of oxidized glutathione, all are highly potent scavengers of peroxynitrite at the studied concentrations.

  18. [Rapid prenatal genetic diagnosis of a fetus with a high risk for Morquio A syndrome].

    PubMed

    Guo, Yi-bin; Ai, Yang; Zhao, Yan; Tang, Jia; Jiang, Wei-ying; Du, Min-lian; Ma, Hua-mei; Zhong, Yan-fang

    2012-04-01

    To provide rapid and accurate prenatal genetic diagnosis for a fetus with high risk of Morquio A syndrome. Based on ascertained etiology of the proband and genotypes of the parents, particular mutations of the GALNS gene were screened at 10th gestational week with amplification refractory mutation system (ARMS), denaturing high performance liquid chromatography (DHPLC), and direct DNA sequencing. DHPLC screening has identified abnormal double peaks in the PCR products of exons 1 and 10, whilst only a single peak was detected in normal controls. Amplification of ARMS specific primers derived a specific product for the fetus's gene, whilst no similar product was detected in normal controls. Sequencing of PCR products confirmed that exons 1 and 10 of the GALNS gene from the fetus contained a heterozygous paternal c.106-111 del (p.L36-L37 del) deletion and a heterozygous maternal c.1097 T>C (p.L366P) missense mutation, which resulted in a compound heterozygote status. The fetus was diagnosed with Morquio A syndrome and a genotype similar to the proband. Termination of the pregnancy was recommended. Combined ARMS, DHPLC and DNA sequencing are effective for rapid and accurate prenatal diagnosis for fetus with a high risk for Morquio A syndrome. Such methods are particularly suitable for early diagnosis when pathogenesis is clear. Furthermore, combined ARMS and DHPLC are suitable for rapid processing of large numbers of samples for the identification of new mutations.

  19. Is there a common motor dysregulation in sleepwalking and REM sleep behaviour disorder?

    PubMed

    Haridi, Mehdi; Weyn Banningh, Sebastian; Clé, Marion; Leu-Semenescu, Smaranda; Vidailhet, Marie; Arnulf, Isabelle

    2017-10-01

    This study sought to determine if there is any overlap between the two major non-rapid eye movement and rapid eye movement parasomnias, i.e. sleepwalking/sleep terrors and rapid eye movement sleep behaviour disorder. We assessed adult patients with sleepwalking/sleep terrors using rapid eye movement sleep behaviour disorder screening questionnaires and determined if they had enhanced muscle tone during rapid eye movement sleep. Conversely, we assessed rapid eye movement sleep behaviour disorder patients using the Paris Arousal Disorders Severity Scale and determined if they had more N3 awakenings. The 251 participants included 64 patients with rapid eye movement sleep behaviour disorder (29 with idiopathic rapid eye movement sleep behaviour disorder and 35 with rapid eye movement sleep behaviour disorder associated with Parkinson's disease), 62 patients with sleepwalking/sleep terrors, 66 old healthy controls (age-matched with the rapid eye movement sleep behaviour disorder group) and 59 young healthy controls (age-matched with the sleepwalking/sleep terrors group). They completed the rapid eye movement sleep behaviour disorder screening questionnaire, rapid eye movement sleep behaviour disorder single question and Paris Arousal Disorders Severity Scale. In addition, all the participants underwent a video-polysomnography. The sleepwalking/sleep terrors patients scored positive on rapid eye movement sleep behaviour disorder scales and had a higher percentage of 'any' phasic rapid eye movement sleep without atonia when compared with controls; however, these patients did not have higher tonic rapid eye movement sleep without atonia or complex behaviours during rapid eye movement sleep. Patients with rapid eye movement sleep behaviour disorder had moderately elevated scores on the Paris Arousal Disorders Severity Scale but did not exhibit more N3 arousals (suggestive of non-rapid eye movement parasomnia) than the control group. These results indicate that dream-enacting behaviours (assessed by rapid eye movement sleep behaviour disorder screening questionnaires) are commonly reported by sleepwalking/sleep terrors patients, thus decreasing the questionnaire's specificity. Furthermore, sleepwalking/sleep terrors patients have excessive twitching during rapid eye movement sleep, which may result either from a higher dreaming activity in rapid eye movement sleep or from a more generalised non-rapid eye movement/rapid eye movement motor dyscontrol during sleep. © 2017 European Sleep Research Society.

  20. The Howard University Hospital Experience with Routineized HIV Screening: A Progress Report*

    PubMed Central

    Scott, Victor F.; Sitapati, Amy; Martin, Sayyida; Summers, Pamela; Washington, Michael; Daniels, Fernando; Mouton, Charles; Bonney, George; Apprey, Victor; Webster, Virginia; Smith, Avemaria; Mountvarner, Geoffrey; Daftary, Monica; Maxwell, Celia J.

    2009-01-01

    Background: Howard University Hospital (HUH) is the first hospital in the nation to have instituted a hospital-wide routine rapid HIV screening campaign as recommended by the CDC for healthcare settings. Methods: HUH developed a protocol and implemented a hospital-wide routine HIV screening in October 2006. Rapid oral fluid-based HIV testing was conducted throughout the hospital using the OraSure OraQuick Advance Rapid HIV-1/2 Antibody Test. Patients with a preliminarily reactive test result were either referred for confirmatory testing or offered a Western Blot confirmatory test on-site and referred for follow-up care. This is a report on the progress of this program for the first eight months. Results: Of the 9,817 patients offered HIV testing, 5,642 consented. The mean age of the screened population was 40.7 years. Ninety percent of the patients screened were black and 55% were female. A preliminarily reactive test result was identified in 139 patients for a seroprevalence rate of 2.46%. Of these patients, 136, or 98% were black; 63% were male and 37% were female. HIV prevalence in the overall sample, among blacks, and among both black males and females peaked in the 40–54 year old age group. Challenges were experienced initially in securing confirmatory tests. Conclusions: Hospital-wide routine HIV screening is both possible and productive. The routine HIV screening campaign instituted at Howard University Hospital has identified a significant number of previously unidentified HIV positive persons. Success in assuring confirmatory testing and transition to care improved as time progressed. PMID:19768195

  1. The Howard University Hospital experience with routineized HIV screening: a progress report.

    PubMed

    Scott, Victor F; Sitapati, Amy; Martin, Sayyida; Summers, Pamela; Washington, Michael; Daniels, Fernando; Mouton, Charles; Bonney, George; Apprey, Victor; Webster, Virginia; Smith, Avemaria; Mountvarner, Geoffrey; Daftary, Monica; Maxwell, Celia J

    2009-01-01

    Howard University Hospital (HUH) is the first hospital in the nation to have instituted a hospital-wide routine rapid HIV screening campaign as recommended by the CDC for healthcare settings. HUH developed a protocol and implemented a hospital-wide routine HIV screening in October 2006. Rapid oral fluid-based HIV testing was conducted throughout the hospital using the OraSure OraQuick Advance Rapid HIV-1/2 Antibody Test. Patients with a preliminarily reactive test result were either referred for confirmatory testing or offered a Western Blot confirmatory test on-site and referred for follow-up care. This is a report on the progress of this program for the first eight months. Of the 9,817 patients offered HIV testing, 5,642 consented. The mean age of the screened population was 40.7 years. Ninety percent of the patients screened were black and 55% were female. A preliminarily reactive test result was identified in 139 patients for a seroprevalence rate of 2.46%. Of these patients, 136, or 98% were black; 63% were male and 37% were female. HIV prevalence in the overall sample, among blacks, and among both black males and females peaked in the 40-54 year old age group. Challenges were experienced initially in securing confirmatory tests. Hospital-wide routine HIV screening is both possible and productive. The routine HIV screening campaign instituted at Howard University Hospital has identified a significant number of previously unidentified HIV positive persons. Success in assuring confirmatory testing and transition to care improved as time progressed.

  2. ATHENA, the Desktop Human "Body"

    ScienceCinema

    Iyer, Rashi; Harris, Jennifer

    2018-05-18

    Creating surrogate human organs, coupled with insights from highly sensitive mass spectrometry technologies, a new project is on the brink of revolutionizing the way we screen new drugs and toxic agents. ATHENA, the Advanced Tissue-engineered Human Ectypal Network Analyzer project team, is developing four human organ constructs - liver, heart, lung and kidney - that are based on a significantly miniaturized platform. Each organ component will be about the size of a smartphone screen, and the whole ATHENA "body" of interconnected organs would fit neatly on a desk. "By developing this 'homo minutus,' we are stepping beyond the need for animal or Petri dish testing: There are huge benefits in developing drug and toxicity analysis systems that can mimic the response of actual human organs," said Rashi Iyer, a senior scientist at Los Alamos National Laboratory, the lead laboratory on the five-year, $19 million multi-institutional effort. The project is supported by the Defense Threat Reduction Agency (DTRA). Some 40 percent of pharmaceuticals fail their clinical trials, Iyer noted, and there are thousands of chemicals whose effects on humans are simply unknown. Providing a realistic, cost-effective and rapid screening system such as ATHENA with high-throughput capabilities could provide major benefits to the medical field, screening more accurately and offering a greater chance of clinical trial success.

  3. ATHENA, the Desktop Human "Body"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iyer, Rashi; Harris, Jennifer

    2014-09-29

    Creating surrogate human organs, coupled with insights from highly sensitive mass spectrometry technologies, a new project is on the brink of revolutionizing the way we screen new drugs and toxic agents. ATHENA, the Advanced Tissue-engineered Human Ectypal Network Analyzer project team, is developing four human organ constructs - liver, heart, lung and kidney - that are based on a significantly miniaturized platform. Each organ component will be about the size of a smartphone screen, and the whole ATHENA "body" of interconnected organs would fit neatly on a desk. "By developing this 'homo minutus,' we are stepping beyond the need formore » animal or Petri dish testing: There are huge benefits in developing drug and toxicity analysis systems that can mimic the response of actual human organs," said Rashi Iyer, a senior scientist at Los Alamos National Laboratory, the lead laboratory on the five-year, $19 million multi-institutional effort. The project is supported by the Defense Threat Reduction Agency (DTRA). Some 40 percent of pharmaceuticals fail their clinical trials, Iyer noted, and there are thousands of chemicals whose effects on humans are simply unknown. Providing a realistic, cost-effective and rapid screening system such as ATHENA with high-throughput capabilities could provide major benefits to the medical field, screening more accurately and offering a greater chance of clinical trial success.« less

  4. A method for the rapid detection of urinary tract infections.

    PubMed

    Olsson, Carl; Kapoor, Deepak; Howard, Glenn

    2012-04-01

    To determine the reliability of a rapid detection method compared with the reference standard streaked agar plate in diagnosing the presence of urinary tract infection (UTI). De-identified clean catch urine specimens from 980 office visit patients were processed during a 30-day period. Classic 1-μL and 10-μL streaked agar plates were used in parallel with the new CultureStat Rapid UTI Detection System (CSRUDS). Urine results were evaluated using the CSRUDS at 30 and 90 minutes after collection. A comparative analysis of the subsequent plate results versus the CSRUDS results was achieved for 973 of these samples. Positive UTI conditions were accurately identified by both CSRUDS and agar streak plate methods. CSRUDS accurately identified UTI negative conditions with 99.3% reliability at 90 minutes. The negative predictive value of CSRUDS was 99.2% at 30 minutes. Current agar plating for first-round UTI screening has substantial documented problems that can negatively affect an accurate and timely UTI diagnosis. A novel rapid detection system, the CSRUDS provides UTI negative/positive same-day results in ≤ 90 minutes from the start of test. Such rapidly available results will enable more accurate and timely clinical decisions to be made in the urology office, particularly regarding infection status before urologic instrumentation. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Screening technologies for detection of swallowed packages of narcotics

    NASA Astrophysics Data System (ADS)

    Burnett, Lowell J.; Magnuson, Erik E.; Sheldon, Alan G.; Kumar, Sankaran

    1997-01-01

    An increasingly popular method of transporting modest quantities of narcotics across international borders is to employ 'swallowers'. These are people who typically enter the country as international airline passengers after swallowing small, water-tight packages of heroin and/or cocaine. Rapid and accurate identification of swallowers in the airport environment poses difficult technical changes. Commonly used medical inspection technologies fall into one of two categories. Either they are unsuitable for widespread use, or they do not provide adequate information. An example of the former is x-ray scanning, while an example of the latter is ultrasonic imaging. Quantum Magnetics has developed a system to screen selected airline passengers for the presence of swallowed narcotics. The system utilizes magnetic resonance, which provides the physical basis for the magnetic resonance imaging systems widely used in the medical community as an alternative to x-rays. The system is currently operational, and laboratory performance testing is complete. Both the design of the system and its performance will be discussed. This work was sponsored in part by the Office of National Drug Control Policy and the US Customs Service.

  6. Final Report Nucleic Acid System - Hybrid PCR and Multiplex Assay Project Phase 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koopman, R P; Langlois, R G; Nasarabadi, S

    2002-04-17

    This report covers phase 2 (year 2) of the Nucleic Acid System--Hybrid PCR and Multiplex Assay project. The objective of the project is to reduce to practice the detection and identification of biological warfare pathogens by the nucleic acid recognition technique of PCR (polymerase chain reaction) in a multiplex mode using flow cytometry. The Hybrid instrument consists of a flow-through PCR module capable of handling a multiplexed PCR assay, a hybridizing module capable of hybridizing multiplexed PCR amplicons and beads, and a flow cytometer module for bead-based identification, all controlled by a single computer. Multiplex immunoassay using bead-based Luminex flowmore » cytometry is available, allowing rapid screening for many agents. PCR is highly specific and complements and verifies immunoassay. It can also be multiplexed and detection provided using the bead-based Luminex flow cytometer. This approach allows full access to the speed and 100-fold multiplex capability of flow cytometry for rapid screening as well as the accuracy and specificity of PCR. This project has two principal activities: (1) Design, build and test a prototype hybrid PCR/flow cytometer with the basic capabilities for rapid, broad spectrum detection and identification, and (2) Develop and evaluate multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products. This project requires not only building operationally functional instrumentation but also developing the chemical assays for detection of priority pathogens. This involves development and evaluation of multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products.« less

  7. Note: Application of CR-39 plastic nuclear track detectors for quality assurance of mixed oxide fuel pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kodaira, S., E-mail: koda@nirs.go.jp; Kurano, M.; Hosogane, T.

    A CR-39 plastic nuclear track detector was used for quality assurance of mixed oxide fuel pellets for next-generation nuclear power plants. Plutonium (Pu) spot sizes and concentrations in the pellets are significant parameters for safe use in the plants. We developed an automatic Pu detection system based on dense α-radiation tracks in the CR-39 detectors. This system would greatly improve image processing time and measurement accuracy, and will be a powerful tool for rapid pellet quality assurance screening.

  8. Top-down production of drug nanocrystals: nanosuspension stabilization, miniaturization and transformation into solid products.

    PubMed

    Van Eerdenbrugh, Bernard; Van den Mooter, Guy; Augustijns, Patrick

    2008-11-19

    During the last 10-15 years, the formulation of drugs as nanocrystals has rapidly evolved into a mature drug delivery strategy, with currently five products on the market. The major characteristic of these systems is the rapid dissolution velocity, enabling bioavailability enhancement after oral administration. This mini-review focuses on recent advances with respect to three topics considering drug nanocrystals. The first topic is nanosuspension stabilization. A current literature status is provided and special attention is given to studies attempting to extend our physicochemical understanding of the underlying principles. The second part describes recent advances on miniaturization of nanosuspension production, to enable formulation screening during preclinical development. Finally, literature available on further nanosuspensions solidification is discussed, focussing on the maintenance of the preservation of the rapid dissolution properties of the nanocrystals after further downstream processing.

  9. Case report: lymphogranuloma venereum proctitis-from rapid screening to molecular confirmation of a masked sexually transmitted disease.

    PubMed

    Markowicz, Mateusz; Grilnberger, Evelyn; Huber, Florian; Leibl, Gabriele; Abrahamian, Heidemarie; Gartner, Manfred; Huber, Monika; Chott, Andreas; Reiter, Michael; Stanek, Gerold

    2013-08-01

    Proctitis caused by Chlamydia trachomatis L2b can manifest with very mild, nonspecific symptoms, and appropriate diagnostic evaluation is crucial. The case report demonstrates that rapid screening test, detection of specific antibodies in serum, and direct pathogen identification by PCR performed on tissue sample or rectal swab allow successful diagnosis of the still emerging sexually transmitted disease among homosexual patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes

    EPA Pesticide Factsheets

    No dataset associated with this publication.This dataset is associated with the following publication:Augustine, S. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes. JOURNAL OF CLINICAL MICROBIOLOGY. American Society for Microbiology, Washington, DC, USA, 56(7): 1-2, (2016).

  11. Rapid bacteriological screening of cosmetic raw materials by using bioluminescence.

    PubMed

    Nielsen, P; Van Dellen, E

    1989-01-01

    Incoming cosmetic raw materials are routinely tested for microbial content. Standard plate count methods require up to 72 h. A rapid, sensitive, and inexpensive raw material screening method was developed that detects the presence of bacteria by means of ATP (bioluminescence). With a 24-h broth enrichment, the minimum bacterial ATP detection threshold of 1 cfu/g sample can be achieved using purified firefly luciferin-luciferase and an ATP releasing reagent. By using this rapid screen, microbiologically free material may be released for production within 24 h, while contaminated material undergoes further quantitative and identification testing. In order for a raw material to be validated for this method it must be evaluated for (1) a potential nonmicrobial light-contributing reaction resulting in a false positive or, (2) degradation of the ATP giving a false negative, and (3) confirmation that the raw material has not overwhelmed the buffering capacity of the enrichment broth. The key criteria for a rapid screen was the sensitivity to detect less than one colony forming unit per g product, the speed to do this within 24 h, and cost efficiency. Bioluminescence meets these criteria. With an enrichment step, it can detect less than one cfu/g sample. After the enrichment step, analysis time per sample is approximately 2 min and the cost for material and reagents is less than one dollar per sample.

  12. Economic evaluation of prostate cancer screening test as a national cancer screening program in South Korea.

    PubMed

    Shin, Sangjin; Kim, Youn Hee; Hwang, Jin Sub; Lee, Yoon Jae; Lee, Sang Moo; Ahn, Jeonghoon

    2014-01-01

    Prostate cancer is rapidly increasing in Korea and professional societies have requested adding prostate specific antigen (PSA) testing to the National Cancer Screening Program (NCSP), but this started a controversy in Korea and neutral evidence on this issue is required more than ever. The purpose of this study was to provide economic evidence to the decision makers of the NCSP. A cost-utility analysis was performed on the adoption of PSA screening program among men aged 50-74-years in Korea from the healthcare system perspective. Several data sources were used for the cost-utility analysis, including general health screening data, the Korea Central Cancer Registry, national insurance claims data, and cause of mortality from the National Statistical Office. To solicit the utility index of prostate cancer, a face-to-face interview for typical men aged 40 to 69 was conducted using a Time-Trade Off method. As a result, the increase of effectiveness was estimated to be very low, when adopting PSA screening, and the incremental cost effectiveness ratio (ICER) was analyzed as about 94 million KRW. Sensitivity analyses were performed on the incidence rate, screening rate, cancer stage distribution, utility index, and treatment costs but the results were consistent with the base analysis. Under Korean circumstances with a relatively low incidence rate of prostate cancer, PSA screening is not cost-effective. Therefore, we conclude that adopting national prostate cancer screening would not be beneficial until further evidence is provided in the future.

  13. FY02 CBNP Annual Report Input: Bioinformatics Support for CBNP Research and Deployments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slezak, T; Wolinsky, M

    2002-10-31

    The events of FY01 dynamically reprogrammed the objectives of the CBNP bioinformatics support team, to meet rapidly-changing Homeland Defense needs and requests from other agencies for assistance: Use computational techniques to determine potential unique DNA signature candidates for microbial and viral pathogens of interest to CBNP researcher and to our collaborating partner agencies such as the Centers for Disease Control and Prevention (CDC), U.S. Department of Agriculture (USDA), Department of Defense (DOD), and Food and Drug Administration (FDA). Develop effective electronic screening measures for DNA signatures to reduce the cost and time of wet-bench screening. Build a comprehensive system formore » tracking the development and testing of DNA signatures. Build a chain-of-custody sample tracking system for field deployment of the DNA signatures as part of the BASIS project. Provide computational tools for use by CBNP Biological Foundations researchers.« less

  14. Implementing a Commercial Rule Base as a Medication Order Safety Net

    PubMed Central

    Reichley, Richard M.; Seaton, Terry L.; Resetar, Ervina; Micek, Scott T.; Scott, Karen L.; Fraser, Victoria J.; Dunagan, W. Claiborne; Bailey, Thomas C.

    2005-01-01

    A commercial rule base (Cerner Multum) was used to identify medication orders exceeding recommended dosage limits at five hospitals within BJC HealthCare, an integrated health care system. During initial testing, clinical pharmacists determined that there was an excessive number of nuisance and clinically insignificant alerts, with an overall alert rate of 9.2%. A method for customizing the commercial rule base was implemented to increase rule specificity for problematic rules. The system was subsequently deployed at two facilities and achieved alert rates of less than 1%. Pharmacists screened these alerts and contacted ordering physicians in 21% of cases. Physicians made therapeutic changes in response to 38% of alerts presented to them. By applying simple techniques to customize rules, commercial rule bases can be used to rapidly deploy a safety net to screen drug orders for excessive dosages, while preserving the rule architecture for later implementations of more finely tuned clinical decision support. PMID:15802481

  15. Combinatorial Libraries of Arrayable Single-Chain Antibodies

    NASA Astrophysics Data System (ADS)

    Benhar, Itai

    Antibodies that bind their respective targets with high affinity and specificity have proven to be essential reagents for biological research. Antibody phage display has become the leading tool for the rapid isolation of single-chain variable fragment (scFv) antibodies in vitro for research applications, but there is usually a gap between scFv isolation and its application in an array format suitable for high-throughput proteomics. In this chapter, we present our antibody phage display system where antibody isolation and scFv immobilization are facilitated by the design of the phagemid vector used as platform. In our system, the scFvs are fused at their C-termini to a cellulose-binding domain (CBD) and can be immobilized onto cellulose-based filters. This made it possible to develop a unique filter lift screen that allowed the efficient screen for multiple binding specificities, and to directly apply library-derived scFvs in an antibody spotted microarray.

  16. Anterior Eye Imaging with Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  17. Evaluation of a Microbial Sensor as a Tool for Antimicrobial Activity Test of Cosmetic Preservatives.

    PubMed

    Gomyo, Hideyuki; Ookawa, Masaki; Oshibuchi, Kota; Sugamura, Yuriko; Hosokawa, Masahito; Shionoiri, Nozomi; Maeda, Yoshiaki; Matsunaga, Tadashi; Tanaka, Tsuyoshi

    2015-01-01

    For high-throughput screening of novel cosmetic preservatives, a rapid and simple assay to evaluate the antimicrobial activities should be developed because the conventional agar dilution method is time-consuming and labor-intensive. To address this issue, we evaluated a microbial sensor as a tool for rapid antimicrobial activity testing. The sensor consists of an oxygen electrode and a filter membrane that holds the test microorganisms, Staphylococcus aureus and Candida albicans. The antimicrobial activity of the tested cosmetic preservative was evaluated by measuring the current increases corresponding to the decreases in oxygen consumption in the microbial respiration. The current increases detected by the sensor showed positive correlation to the concentrations of two commercially used preservatives, chlorphenesin and 2-phenoxyethanol. The same tendency was also observed when a model cosmetic product was used as a preservative solvent, indicating the feasibility in practical use. Furthermore, the microbial sensor and microfluidic flow-cell was assembled to achieve sequential measurements. The sensor system presented in this study could be useful in large-scale screening experiments.

  18. Applications of Replicating-Competent Reporter-Expressing Viruses in Diagnostic and Molecular Virology.

    PubMed

    Li, Yongfeng; Li, Lian-Feng; Yu, Shaoxiong; Wang, Xiao; Zhang, Lingkai; Yu, Jiahui; Xie, Libao; Li, Weike; Ali, Razim; Qiu, Hua-Ji

    2016-05-06

    Commonly used tests based on wild-type viruses, such as immunostaining, cannot meet the demands for rapid detection of viral replication, high-throughput screening for antivirals, as well as for tracking viral proteins or virus transport in real time. Notably, the development of replicating-competent reporter-expressing viruses (RCREVs) has provided an excellent option to detect directly viral replication without the use of secondary labeling, which represents a significant advance in virology. This article reviews the applications of RCREVs in diagnostic and molecular virology, including rapid neutralization tests, high-throughput screening systems, identification of viral receptors and virus-host interactions, dynamics of viral infections in vitro and in vivo, vaccination approaches and others. However, there remain various challenges associated with RCREVs, including pathogenicity alterations due to the insertion of a reporter gene, instability or loss of the reporter gene expression, or attenuation of reporter signals in vivo. Despite all these limitations, RCREVs have become powerful tools for both basic and applied virology with the development of new technologies for generating RCREVs, the inventions of novel reporters and the better understanding of regulation of viral replication.

  19. Development of an Immunoassay for Rapid Detection of Ganglioside GM1 Mimicry in Campylobacter jejuni Strains

    PubMed Central

    Prendergast, Martina M.; Kosunen, Timo U.; Moran, Anthony P.

    2001-01-01

    Mimicry of peripheral nerve gangliosides by Campylobacter jejuni lipopolysaccharides (LPSs) has been proposed to induce cross-reacting antiganglioside antibodies in Guillain-Barré syndrome (GBS). Because current methods for LPS characterization are labor-intensive and inhibit the screening of large numbers of strains, a rapid GM1 epitope screening assay was developed. Biomass from two agar plates of confluent growth yielded sufficient LPS using a novel phenol-water and ether extraction procedure. Extracts of LPS were reacted with cholera toxin (GM1 ligand), peanut agglutinin (Galβ1→3GalNAc ligand), and anti-GM1 antibodies. After the assay was validated, 12 of 59 (20%) C. jejuni serostrains, including four serotypes that have not previously been associated with GBS, reacted with two or more anti-GM1 ganglioside reagents. Subsequently, LPS extracts from 5 of 7 (71%) C. jejuni isolates and 2 of 3 (67%) C. jejuni culture collection strains bore GM1 structures. Overall, the assay system was reliable, efficient, and reproducible and may be adapted for large-scale epidemiological studies. PMID:11283076

  20. Application of handheld and portable spectrometers for screening acrylamide content in commercial potato chips.

    PubMed

    Ayvaz, Huseyin; Rodriguez-Saona, Luis E

    2015-05-01

    The most common methods for acrylamide analysis in foods require the use of LC-MS/MS and GC-MS. Although these methods have great analytical performance, they need intensive sample preparation, highly specialised instrumentation, and are time consuming. In this study, portable and handheld infrared spectrometers were evaluated as rapid methods for screening acrylamide in potato chips and their performances were compared to those of benchtop infrared systems. The acrylamide content of 64 commercial potato chips (169-2453 μg/kg) was determined by LC-MS/MS. Spectral data were collected using mid-infrared (MIR) and near-infrared (NIR) spectrometers. Partial least squares regression (PLSR) calibration models were developed to predict acrylamide levels. Overall, good linear correlation was found between the predicted acrylamide levels and actual measured acrylamide concentrations by LC-MS/MS (rPred > 0.90 and SEP < 100 μg/kg). Our results indicate that portable and handheld spectrometers can be used as simple and rapid alternatives for acrylamide analysis in potato chips. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Rapid screening for human-pathogenic Mucorales using rolling circle amplification.

    PubMed

    Dolatabadi, S; Najafzadeh, M J; de Hoog, G S

    2014-12-01

    Mucormycosis has emerged as a relatively common severe mycosis in patients with haematological and allogeneic stem cell transplantation. Source of transmission is from unidentified sources in the environment. Early diagnosis of infection and its source of contamination are paramount for rapid and appropriate therapy. In this study, rolling circle amplification (RCA) is introduced as a sensitive, specific and reproducible isothermal DNA amplification technique for rapid molecular identification of six of the most virulent species (Rhizopus microsporus, R. arrhizus var. arrhizus, R. arrhizus var. delemar, Mucor irregularis, Mucor circinelloides, Lichtheimia ramosa, Lichtheimia corymbifera). DNAs of target species were successfully amplified, with no cross reactivity between species. RCA can be considered as a rapid detection method with high specificity and sensitivity, suitable for large screening. © 2014 Blackwell Verlag GmbH.

  2. Exploring the Potential of a Global Emerging Contaminant Early Warning Network through the Use of Retrospective Suspect Screening with High-Resolution Mass Spectrometry.

    PubMed

    Alygizakis, Nikiforos A; Samanipour, Saer; Hollender, Juliane; Ibáñez, María; Kaserzon, Sarit; Kokkali, Varvara; van Leerdam, Jan A; Mueller, Jochen F; Pijnappels, Martijn; Reid, Malcolm J; Schymanski, Emma L; Slobodnik, Jaroslav; Thomaidis, Nikolaos S; Thomas, Kevin V

    2018-05-01

    A key challenge in the environmental and exposure sciences is to establish experimental evidence of the role of chemical exposure in human and environmental systems. High resolution and accurate tandem mass spectrometry (HRMS) is increasingly being used for the analysis of environmental samples. One lauded benefit of HRMS is the possibility to retrospectively process data for (previously omitted) compounds that has led to the archiving of HRMS data. Archived HRMS data affords the possibility of exploiting historical data to rapidly and effectively establish the temporal and spatial occurrence of newly identified contaminants through retrospective suspect screening. We propose to establish a global emerging contaminant early warning network to rapidly assess the spatial and temporal distribution of contaminants of emerging concern in environmental samples through performing retrospective analysis on HRMS data. The effectiveness of such a network is demonstrated through a pilot study, where eight reference laboratories with available archived HRMS data retrospectively screened data acquired from aqueous environmental samples collected in 14 countries on 3 different continents. The widespread spatial occurrence of several surfactants (e.g., polyethylene glycols ( PEGs ) and C12AEO-PEGs ), transformation products of selected drugs (e.g., gabapentin-lactam, metoprolol-acid, carbamazepine-10-hydroxy, omeprazole-4-hydroxy-sulfide, and 2-benzothiazole-sulfonic-acid), and industrial chemicals (3-nitrobenzenesulfonate and bisphenol-S) was revealed. Obtaining identifications of increased reliability through retrospective suspect screening is challenging, and recommendations for dealing with issues such as broad chromatographic peaks, data acquisition, and sensitivity are provided.

  3. Universal Versus Targeted Screening for Lynch Syndrome: Comparing Ascertainment and Costs Based on Clinical Experience.

    PubMed

    Erten, Mujde Z; Fernandez, Luca P; Ng, Hank K; McKinnon, Wendy C; Heald, Brandie; Koliba, Christopher J; Greenblatt, Marc S

    2016-10-01

    Strategies to screen colorectal cancers (CRCs) for Lynch syndrome are evolving rapidly; the optimal strategy remains uncertain. We compared targeted versus universal screening of CRCs for Lynch syndrome. In 2010-2011, we employed targeted screening (age < 60 and/or Bethesda criteria). From 2012 to 2014, we screened all CRCs. Immunohistochemistry for the four mismatch repair proteins was done in all cases, followed by other diagnostic studies as indicated. We modeled the diagnostic costs of detecting Lynch syndrome and estimated the 5-year costs of preventing CRC by colonoscopy screening, using a system dynamics model. Using targeted screening, 51/175 (29 %) cancers fit criteria and were tested by immunohistochemistry; 15/51 (29 %, or 8.6 % of all CRCs) showed suspicious loss of ≥1 mismatch repair protein. Germline mismatch repair gene mutations were found in 4/4 cases sequenced (11 suspected cases did not have germline testing). Using universal screening, 17/292 (5.8 %) screened cancers had abnormal immunohistochemistry suspicious for Lynch syndrome. Germline mismatch repair mutations were found in only 3/10 cases sequenced (7 suspected cases did not have germline testing). The mean cost to identify Lynch syndrome probands was ~$23,333/case for targeted screening and ~$175,916/case for universal screening at our institution. Estimated costs to identify and screen probands and relatives were: targeted, $9798/case and universal, $38,452/case. In real-world Lynch syndrome management, incomplete clinical follow-up was the major barrier to do genetic testing. Targeted screening costs 2- to 7.5-fold less than universal and rarely misses Lynch syndrome cases. Future changes in testing costs will likely change the optimal algorithm.

  4. Evaluation of a QuECHERS-like extraction approach for the determination of PBDEs in mussels by immuno-assay-based screening methods

    USDA-ARS?s Scientific Manuscript database

    A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. A simple sample preparation in conjunction with a rapid screening method possesses the desired c...

  5. A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koh, Chung-Yan; Piccini, Matthew Ernest; Schaff, Ulrich Y.

    Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding ofmore » toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.« less

  6. Comparison of a rational vs. high throughput approach for rapid salt screening and selection.

    PubMed

    Collman, Benjamin M; Miller, Jonathan M; Seadeek, Christopher; Stambek, Julie A; Blackburn, Anthony C

    2013-01-01

    In recent years, high throughput (HT) screening has become the most widely used approach for early phase salt screening and selection in a drug discovery/development setting. The purpose of this study was to compare a rational approach for salt screening and selection to those results previously generated using a HT approach. The rational approach involved a much smaller number of initial trials (one salt synthesis attempt per counterion) that were selected based on a few strategic solubility determinations of the free form combined with a theoretical analysis of the ideal solvent solubility conditions for salt formation. Salt screening results for sertraline, tamoxifen, and trazodone using the rational approach were compared to those previously generated by HT screening. The rational approach produced similar results to HT screening, including identification of the commercially chosen salt forms, but with a fraction of the crystallization attempts. Moreover, the rational approach provided enough solid from the very initial crystallization of a salt for more thorough and reliable solid-state characterization and thus rapid decision-making. The crystallization techniques used in the rational approach mimic larger-scale process crystallization, allowing smoother technical transfer of the selected salt to the process chemist.

  7. Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

    PubMed Central

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-01

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 μM for methanol and 0.2 μM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement. PMID:24412899

  8. Bienzymatic biosensor for rapid detection of aspartame by flow injection analysis.

    PubMed

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-09

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.

  9. Rapid, autonomous analysis of He spectra I: Overview of the RadID program, user experience, and structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gosnell, Thomas B.; Chavez, Joseph R.; Rowland, Mark S.

    2014-02-26

    RadID is a new gamma-ray spectrum analysis program for rapid screening of HPGe gamma-ray data to reveal the presence of radionuclide signatures. It is an autonomous, rule-based heuristic system that can identify well over 200 radioactive sources with particular interest in uranium and plutonium characteristics. It executes in about one second. RadID does not require knowledge of the detector efficiency, the source-to-detector distance, or the geometry of the inspected radiation source—including any shielding. In this first of a three-document series we sketch the RadID program’s origin, its minimal requirements, the user experience, and the program operation.

  10. Lead discovery for mammalian elongation of long chain fatty acids family 6 using a combination of high-throughput fluorescent-based assay and RapidFire mass spectrometry assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takamiya, Mari; Discovery Technology Laboratories, Sohyaku, Innovative Research Division, Mitsubishi Tanabe Pharma Corporation, Kawagishi, Toda-shi, Saitama; Sakurai, Masaaki

    A high-throughput RapidFire mass spectrometry assay is described for elongation of very long-chain fatty acids family 6 (Elovl6). Elovl6 is a microsomal enzyme that regulates the elongation of C12-16 saturated and monounsaturated fatty acids. Elovl6 may be a new therapeutic target for fat metabolism disorders such as obesity, type 2 diabetes, and nonalcoholic steatohepatitis. To identify new Elovl6 inhibitors, we developed a high-throughput fluorescence screening assay in 1536-well format. However, a number of false positives caused by fluorescent interference have been identified. To pick up the real active compounds among the primary hits from the fluorescence assay, we developed amore » RapidFire mass spectrometry assay and a conventional radioisotope assay. These assays have the advantage of detecting the main products directly without using fluorescent-labeled substrates. As a result, 276 compounds (30%) of the primary hits (921 compounds) in a fluorescence ultra-high-throughput screening method were identified as common active compounds in these two assays. It is concluded that both methods are very effective to eliminate false positives. Compared with the radioisotope method using an expensive {sup 14}C-labeled substrate, the RapidFire mass spectrometry method using unlabeled substrates is a high-accuracy, high-throughput method. In addition, some of the hit compounds selected from the screening inhibited cellular fatty acid elongation in HEK293 cells expressing Elovl6 transiently. This result suggests that these compounds may be promising lead candidates for therapeutic drugs. Ultra-high-throughput fluorescence screening followed by a RapidFire mass spectrometry assay was a suitable strategy for lead discovery against Elovl6. - Highlights: • A novel assay for elongation of very-long-chain fatty acids 6 (Elovl6) is proposed. • RapidFire mass spectrometry (RF-MS) assay is useful to select real screening hits. • RF-MS assay is proved to be beneficial because of its high-throughput and accuracy. • A combination of fluorescent and RF-MS assays is effective for Elovl6 inhibitors.« less

  11. High-throughput screening of a CRISPR/Cas9 library for functional genomics in human cells.

    PubMed

    Zhou, Yuexin; Zhu, Shiyou; Cai, Changzu; Yuan, Pengfei; Li, Chunmei; Huang, Yanyi; Wei, Wensheng

    2014-05-22

    Targeted genome editing technologies are powerful tools for studying biology and disease, and have a broad range of research applications. In contrast to the rapid development of toolkits to manipulate individual genes, large-scale screening methods based on the complete loss of gene expression are only now beginning to be developed. Here we report the development of a focused CRISPR/Cas-based (clustered regularly interspaced short palindromic repeats/CRISPR-associated) lentiviral library in human cells and a method of gene identification based on functional screening and high-throughput sequencing analysis. Using knockout library screens, we successfully identified the host genes essential for the intoxication of cells by anthrax and diphtheria toxins, which were confirmed by functional validation. The broad application of this powerful genetic screening strategy will not only facilitate the rapid identification of genes important for bacterial toxicity but will also enable the discovery of genes that participate in other biological processes.

  12. Evaluation of a rapid quantitative determination method of PSA concentration with gold immunochromatographic strips.

    PubMed

    Wu, Cheng-Ching; Lin, Hung-Yu; Wang, Chao-Ping; Lu, Li-Fen; Yu, Teng-Hung; Hung, Wei-Chin; Houng, Jer-Yiing; Chung, Fu-Mei; Lee, Yau-Jiunn; Hu, Jin-Jia

    2015-11-03

    Prostate cancer remains the most common cancer in men. Qualitative or semi-quantitative immunochromatographic measurements of prostate specific antigen (PSA) have been shown to be simple, noninvasive and feasible. The aim of this study was to evaluate an optimized gold immunochromatographic strip device for the detection of PSA, in which the results can be analysed using a Chromogenic Rapid Test Reader to quantitatively assess the test results. This reader measures the reflectance of the signal line via a charge-coupled device camera. For quantitative analysis, PSA concentration was computed via a calibration equation. Capillary blood samples from 305 men were evaluated, and two independent observers interpreted the test results after 12 min. Blood samples were also collected and tested with a conventional quantitative assay. Sensitivity, specificity, positive and negative predictive values, and accuracy of the PSA rapid quantitative test system were 100, 96.6, 89.5, 100, and 97.4 %, respectively. Reproducibility of the test was 99.2, and interobserver variation was 8 % with a false positive rate of 3.4 %. The correlation coefficient between the ordinary quantitative assay and the rapid quantitative test was 0.960. The PSA rapid quantitative test system provided results quickly and was easy to use, so that tests using this system can be easily performed at outpatient clinics or elsewhere. This system may also be useful for initial cancer screening and for point-of-care testing, because results can be obtained within 12 min and at a cost lower than that of conventional quantitative assays.

  13. The rat whole embryo culture assay using the Dysmorphology Score system.

    PubMed

    Zhang, Cindy; Panzica-Kelly, Julie; Augustine-Rauch, Karen

    2013-01-01

    The rat whole embryo culture (WEC) system has been used extensively for characterizing teratogenic properties of test chemicals. In this chapter, we describe the methodology for culturing rat embryos as well as a new morphological score system, the Dysmorphology Score (DMS) system for assessing morphology of mid gestation (gestational day 11) rat embryos. In contrast to the developmental stage focused scoring associated with the Brown and Fabro score system, this new score system assesses the respective degree of severity of dysmorphology, which delineates normal from abnormal morphology of specific embryonic structures and organ systems. This score system generates an approach that allows rapid identification and quantification of adverse developmental findings, making it conducive for characterization of compounds for teratogenic properties and screening activities.

  14. Effects of medicinal compounds on the differentiation of the eukaryotic microorganism dictyostelium discoideum: can this model be used as a screening test for reproductive toxicity in humans?

    PubMed

    Dannat, K; Tillner, J; Winckler, T; Weiss, M; Eger, K; Dingermann, T

    2003-03-01

    Dictyostelium discoideum is a single-cell, eukaryotic microorganism that can undergo multicellular development in order to produce dormant spores. We investigated the capacity of D. discoideum to be used as a rapid screening system for potential developmental toxicity of compounds under development as pharmaceuticals. We used a set of four transgenic D. discoideum strains that expressed a reporter gene under the control of promoters that are active at certain time periods and in distinct cell types during D. discoideum development. We found that teratogens such as valproic acid, tretinoin, or thalidomide interfered to various extents with D. discoideum development, and had different effects on prestalk and prespore cell-specific reporter gene expression. Phenytoin was inactive in this assay, which may point to limitations in metabolization of the compound in Dictyostelium required to exert developmental toxicity. D. discoideum cell culture is cheap and easy to handle compared to mammalian cell cultures or animal teratogenicity models. Although the Dictyostelium-based assay described in this report may not securely predict the teratogenic potential of these drugs in humans, this organism may be qualified for rapid large-scale screenings of synthetic compounds under development as new pharmaceuticals for their potential to interfere with developmental processes and thus help to reduce the amount of teratogenicity tests in animal models.

  15. Short communication: Development of a direct in vivo screening model to identify potential probiotic bacteria using Caenorhabditis elegans.

    PubMed

    Park, M R; Yun, H S; Son, S J; Oh, S; Kim, Y

    2014-11-01

    Caenorhabditis elegans is an accepted model host to study host-bacteria interactions in the gut, in addition to being a simple model with which to study conserved aspects of biological signaling pathways in intestinal environments, because these nematode worms have similar intestinal cells to those of humans. Here, we used C. elegans to develop a new in vivo screening system for potential probiotic lactic acid bacteria (LAB). Initially, critical colonization ability of LAB strains isolated from Korean infant feces was screened in the worm intestinal tract over a period of 5 d. Furthermore, we investigated host health-promoting activities, including longevity-extending effects and immune-enhancing activities against foodborne pathogen infection. We identified 4 LAB strains that were highly persistent in the nematode gut and that significantly prolonged the longevity of C. elegans and improved the survival of C. elegans in response to infection by Staphylococcus aureus. The 4 LAB strains we identified showed resistance to acid and bile conditions, assimilated cholesterol, and were able to attach to a mucus layer. The 4 LAB isolates were identified as Lactobacillus plantarum using 16S rRNA sequencing analysis. Taken together, we developed a direct in vivo screening system using C. elegans to study host health-promoting LAB. Our system is simple, rapid, cost-effective, and reliable, and we anticipate that this system will result in the discovery of many more potential probiotic bacteria for dairy foods. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Screening For Alcohol-Producing Microbes

    NASA Technical Reports Server (NTRS)

    Schubert, Wayne W.

    1988-01-01

    Dye reaction rapidly identifies alcohol-producing microbial colonies. Method visually detects alcohol-producing micro-organisms, and distinguishes them from other microbial colonies that do not produce alcohol. Method useful for screening mixed microbial populations in environmental samples.

  17. Streptococcal screen

    MedlinePlus

    Rapid strep test ... recommend this test if you have signs of strep throat, which include: Fever Sore throat Tender and ... A negative strep screen most often means group A streptococcus is not present. It is unlikely that you have strep throat. ...

  18. Advances in EPA’s Rapid Exposure and Dosimetry Project (Interagency Alternatives Assessment Webinar)

    EPA Science Inventory

    Estimates of human and ecological exposures are required as critical input to risk-based prioritization and screening of chemicals. The CSS Rapid Exposure and Dosimetry project seeks to develop the data, tools, and evaluation approaches required to generate rapid and scientifical...

  19. Evaluation of the Specificity and Sensitivity of a Potential Rapid Influenza Screening System

    DTIC Science & Technology

    2013-01-01

    Linder JA, Singer DE , Stafford RS. Association between antibiotic prescribing and visit duration in adults with upper respiratory tract infections. Clin...collected from emergency department patients presenting with influenza-like symptoms at a large military academic hospital and on de -identified nasal swabs...in the United States (Franck and Smith, 2010; Linder et al., 2003). For instance, in a national ambulatory network study of 52,135 upper respiratory

  20. Economic Evaluation of Screening Strategies Combined with HPV Vaccination of Preadolescent Girls for the Prevention of Cervical Cancer in Vientiane, Lao PDR

    PubMed Central

    2016-01-01

    Background Several approaches to reduce the incidence of invasive cervical cancers exist. The approach adopted should take into account contextual factors that influence the cost-effectiveness of the available options. Objective To determine the cost-effectiveness of screening strategies combined with a vaccination program for 10-year old girls for cervical cancer prevention in Vientiane, Lao PDR. Methods A population-based dynamic compartment model was constructed. The interventions consisted of a 10-year old girl vaccination program only, or this program combined with screening strategies, i.e., visual inspection with acetic acid (VIA), cytology-based screening, rapid human papillomavirus (HPV) DNA testing, or combined VIA and cytology testing. Simulations were run over 100 years. In base-case scenario analyses, we assumed a 70% vaccination coverage with lifelong protection and a 50% screening coverage. The outcome of interest was the incremental cost per Disability-Adjusted Life Year (DALY) averted. Results In base-case scenarios, compared to the next best strategy, the model predicted that VIA screening of women aged 30–65 years old every three years, combined with vaccination, was the most attractive option, costing 2 544 international dollars (I$) per DALY averted. Meanwhile, rapid HPV DNA testing was predicted to be more attractive than cytology-based screening or its combination with VIA. Among cytology-based screening options, combined VIA with conventional cytology testing was predicted to be the most attractive option. Multi-way sensitivity analyses did not change the results. Compared to rapid HPV DNA testing, VIA had a probability of cost-effectiveness of 73%. Compared to the vaccination only option, the probability that a program consisting of screening women every five years would be cost-effective was around 60% and 80% if the willingness-to-pay threshold is fixed at one and three GDP per capita, respectively. Conclusions A VIA screening program in addition to a girl vaccination program was predicted to be the most attractive option in the health care context of Lao PDR. When compared with other screening methods, VIA was the primary recommended method for combination with vaccination in Lao PDR. PMID:27631732

  1. Economic Evaluation of Screening Strategies Combined with HPV Vaccination of Preadolescent Girls for the Prevention of Cervical Cancer in Vientiane, Lao PDR.

    PubMed

    Chanthavilay, Phetsavanh; Reinharz, Daniel; Mayxay, Mayfong; Phongsavan, Keokedthong; Marsden, Donald E; Moore, Lynne; White, Lisa J

    2016-01-01

    Several approaches to reduce the incidence of invasive cervical cancers exist. The approach adopted should take into account contextual factors that influence the cost-effectiveness of the available options. To determine the cost-effectiveness of screening strategies combined with a vaccination program for 10-year old girls for cervical cancer prevention in Vientiane, Lao PDR. A population-based dynamic compartment model was constructed. The interventions consisted of a 10-year old girl vaccination program only, or this program combined with screening strategies, i.e., visual inspection with acetic acid (VIA), cytology-based screening, rapid human papillomavirus (HPV) DNA testing, or combined VIA and cytology testing. Simulations were run over 100 years. In base-case scenario analyses, we assumed a 70% vaccination coverage with lifelong protection and a 50% screening coverage. The outcome of interest was the incremental cost per Disability-Adjusted Life Year (DALY) averted. In base-case scenarios, compared to the next best strategy, the model predicted that VIA screening of women aged 30-65 years old every three years, combined with vaccination, was the most attractive option, costing 2 544 international dollars (I$) per DALY averted. Meanwhile, rapid HPV DNA testing was predicted to be more attractive than cytology-based screening or its combination with VIA. Among cytology-based screening options, combined VIA with conventional cytology testing was predicted to be the most attractive option. Multi-way sensitivity analyses did not change the results. Compared to rapid HPV DNA testing, VIA had a probability of cost-effectiveness of 73%. Compared to the vaccination only option, the probability that a program consisting of screening women every five years would be cost-effective was around 60% and 80% if the willingness-to-pay threshold is fixed at one and three GDP per capita, respectively. A VIA screening program in addition to a girl vaccination program was predicted to be the most attractive option in the health care context of Lao PDR. When compared with other screening methods, VIA was the primary recommended method for combination with vaccination in Lao PDR.

  2. Screening and Rapid Molecular Diagnosis of Tuberculosis in Prisons in Russia and Eastern Europe: A Cost-Effectiveness Analysis

    PubMed Central

    Winetsky, Daniel E.; Negoescu, Diana M.; DeMarchis, Emilia H.; Almukhamedova, Olga; Dooronbekova, Aizhan; Pulatov, Dilshod; Vezhnina, Natalia; Owens, Douglas K.; Goldhaber-Fiebert, Jeremy D.

    2012-01-01

    Background Prisons of the former Soviet Union (FSU) have high rates of multidrug-resistant tuberculosis (MDR-TB) and are thought to drive general population tuberculosis (TB) epidemics. Effective prison case detection, though employing more expensive technologies, may reduce long-term treatment costs and slow MDR-TB transmission. Methods and Findings We developed a dynamic transmission model of TB and drug resistance matched to the epidemiology and costs in FSU prisons. We evaluated eight strategies for TB screening and diagnosis involving, alone or in combination, self-referral, symptom screening, mass miniature radiography (MMR), and sputum PCR with probes for rifampin resistance (Xpert MTB/RIF). Over a 10-y horizon, we projected costs, quality-adjusted life years (QALYs), and TB and MDR-TB prevalence. Using sputum PCR as an annual primary screening tool among the general prison population most effectively reduced overall TB prevalence (from 2.78% to 2.31%) and MDR-TB prevalence (from 0.74% to 0.63%), and cost US$543/QALY for additional QALYs gained compared to MMR screening with sputum PCR reserved for rapid detection of MDR-TB. Adding sputum PCR to the currently used strategy of annual MMR screening was cost-saving over 10 y compared to MMR screening alone, but produced only a modest reduction in MDR-TB prevalence (from 0.74% to 0.69%) and had minimal effect on overall TB prevalence (from 2.78% to 2.74%). Strategies based on symptom screening alone were less effective and more expensive than MMR-based strategies. Study limitations included scarce primary TB time-series data in FSU prisons and uncertainties regarding screening test characteristics. Conclusions In prisons of the FSU, annual screening of the general inmate population with sputum PCR most effectively reduces TB and MDR-TB prevalence, doing so cost-effectively. If this approach is not feasible, the current strategy of annual MMR is both more effective and less expensive than strategies using self-referral or symptom screening alone, and the addition of sputum PCR for rapid MDR-TB detection may be cost-saving over time. Please see later in the article for the Editors' Summary PMID:23209384

  3. RPR test

    MedlinePlus

    Rapid plasma reagin test; Syphilis screening test ... Chernecky CC, Berger BJ. Rapid plasma regain (RPR) test – blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier ...

  4. Diagnostic Methods for Platelet Bacteria Screening: Current Status and Developments

    PubMed Central

    Störmer, Melanie; Vollmer, Tanja

    2014-01-01

    Summary Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes. PMID:24659944

  5. Paper-based microreactor array for rapid screening of cell signaling cascades.

    PubMed

    Huang, Chia-Hao; Lei, Kin Fong; Tsang, Ngan-Ming

    2016-08-07

    Investigation of cell signaling pathways is important for the study of pathogenesis of cancer. However, the related operations used in these studies are time consuming and labor intensive. Thus, the development of effective therapeutic strategies may be hampered. In this work, gel-free cell culture and subsequent immunoassay has been successfully integrated and conducted in a paper-based microreactor array. Study of the activation level of different kinases of cells stimulated by different conditions, i.e., IL-6 stimulation, starvation, and hypoxia, was demonstrated. Moreover, rapid screening of cell signaling cascades after the stimulations of HGF, doxorubicin, and UVB irradiation was respectively conducted to simultaneously screen 40 kinases and transcription factors. Activation of multi-signaling pathways could be identified and the correlation between signaling pathways was discussed to provide further information to investigate the entire signaling network. The present technique integrates most of the tedious operations using a single paper substrate, reduces sample and reagent consumption, and shortens the time required by the entire process. Therefore, it provides a first-tier rapid screening tool for the study of complicated signaling cascades. It is expected that the technique can be developed for routine protocol in conventional biological research laboratories.

  6. Development of high-performance low-reflection rugged resistive touch screens for military displays

    NASA Astrophysics Data System (ADS)

    Wang, Raymond; Wang, Minshine; Thomas, John; Wang, Lawrence; Chang, Victor

    2010-04-01

    Just as iPhones with sophisticated touch interfaces have revolutionised the human interface for the ubiquitous cell phone, the Military is rapidly adopting touch-screens as a primary interface to their computers and vehicle systems. This paper describes the development of a true military touch interface solution from an existing industrial design. We will report on successful development of 10.4" and 15.4" high performance rugged resistive touch panels using IAD sputter coating. Low reflectance (specular < 1% and diffuse < 0.07%) was achieved with high impact, dust, and chemical resistant surface finishes. These touch panels were qualified over a wide operational temperature range, -51°C to +80°C specifically for military and rugged industrial applications.

  7. Development of an ELA-DRA gene typing method based on pyrosequencing technology.

    PubMed

    Díaz, S; Echeverría, M G; It, V; Posik, D M; Rogberg-Muñoz, A; Pena, N L; Peral-García, P; Vega-Pla, J L; Giovambattista, G

    2008-11-01

    The polymorphism of equine lymphocyte antigen (ELA) class II DRA gene had been detected by polymerase chain reaction-single-strand conformational polymorphism (PCR-SSCP) and reference strand-mediated conformation analysis. These methodologies allowed to identify 11 ELA-DRA exon 2 sequences, three of which are widely distributed among domestic horse breeds. Herein, we describe the development of a pyrosequencing-based method applicable to ELA-DRA typing, by screening samples from eight different horse breeds previously typed by PCR-SSCP. This sequence-based method would be useful in high-throughput genotyping of major histocompatibility complex genes in horses and other animal species, making this system interesting as a rapid screening method for animal genotyping of immune-related genes.

  8. Evaluation of the Premi Test and comparison with the One-Plate Test for the detection of antimicrobials in kidney.

    PubMed

    Cantwell, H; O'Keeffe, M

    2006-02-01

    The Premi Test, a test kit designed for the rapid screening of antimicrobial residues in meat, fish and eggs, was evaluated and compared with the (modified) One-Plate Test, an agar diffusion assay. The performance characteristics described for qualitative, screening methods in Commission Decision 2002/657/EC were used for the evaluation. The Premi Test was found to detect a range of antimicrobials to MRL levels in kidney fluid but to have poorer sensitivity for some antimicrobials such as tetracyclines, sulphonamides, flumequine and streptomycin. The test was found not to be sensitive for the banned antimicrobial chloramphenicol. The One-Plate Test was found to detect most tetracyclines and flumequine to MRL levels but to be less sensitive than the Premi Test for most of the other classes of antimicrobials. Neither test alone provides a comprehensive screening test for antimicrobial residues in kidney at MRL levels. However, the Premi Test is fast, easy to use and rugged and, in combination with other antimicrobial tests, may be used to provide a comprehensive screening system for antimicrobials in tissues.

  9. A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen

    NASA Astrophysics Data System (ADS)

    Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu

    2018-02-01

    Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.

  10. Fast-responder: Rapid mobile-phone access to recent remote sensing imagery for first responders

    NASA Astrophysics Data System (ADS)

    Talbot, L. M.; Talbot, B. G.

    We introduce Fast-Responder, a novel prototype data-dissemination application and architecture concept to rapidly deliver remote sensing imagery to smartphones to enable situational awareness. The architecture implements a Fast-Earth image caching system on the phone and interacts with a Fast-Earth server. Prototype evaluation successfully demonstrated that National Guard users could select a location, download multiple remote sensing images, and flicker between images, all in less than a minute on a 3G mobile commercial link. The Fast-Responder architecture is a significant advance that is designed to meet the needs of mobile users, such as National Guard response units, to rapidly access information during a crisis, such as a natural or man-made disaster. This paper focuses on the architecture design and advanced user interface concepts for small-screens for highly active mobile users. Novel Fast-Responder concepts can also enable rapid dissemination and evaluation of imagery on the desktop, opening new technology horizons for both desktop and mobile users.

  11. Evaluation of the Triage TOX Drug Screen Assay for Detection of 11 Drugs of Abuse and Therapeutic Drugs.

    PubMed

    Bang, Hae In; Jang, Mi Ae; Lee, Yong Wha

    2017-11-01

    The demand for rapid and broad clinical toxicology screens is on the rise. Recently, a new rapid toxicology screening test, the Triage TOX Drug Screen (Alere Inc., USA), which can simultaneously detect 11 drugs of abuse and therapeutic drugs with an instrument-read cartridge, was developed. In the present study, we evaluated the efficacy of this new on-site immunoassay using 105 urine specimens; the results were compared with those obtained by using ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-TMS). Precision was evaluated according to the CLSI EP12-A2 for analyte concentrations near the cutoff, including C₅₀ and±30% of C₅₀, for each drug using standard materials. The C₅₀ specimens yielded 35-65% positive results and the±30% concentration range of all evaluated drugs encompassed the C₅-C₉₅ interval. The overall percent agreement of the Triage TOX Drug Screen was 92.4-100% compared with UPLC-TMS; however, the Triage TOX Drug Screen results showed some discordant cases including acetaminophen, amphetamine, benzodiazepine, opiates, and tricyclic antidepressants. The overall performance of the Triage TOX Drug Screen assay was comparable to that of UPLC-TMS for screening of drug intoxication in hospitals. This assay could constitute a useful screening method for drugs of abuse and therapeutic drugs in urine. © The Korean Society for Laboratory Medicine.

  12. A model for routine hospital-wide HIV screening: lessons learned and public health implications.

    PubMed

    Maxwell, Celia J; Sitapati, Amy M; Abdus-Salaam, Sayyida S; Scott, Victor; Martin, Marsha; Holt-Brockenbrough, Maya E; Retland, Nicole L

    2010-12-01

    Approximately 232700 (21%) of Americans are unaware of their HIV-seropositive status; this represents a potential for virus transmission. Revised recommendations from the Centers for Disease Control for HIV screening promote routine screening in the health care setting. We describe the implementation of a hospital-wide routine HIV screening program in the District of Columbia. Rapid HIV testing was conducted at Howard University Hospital on consenting patients at least 18 years of age using the OraSure OraQuick Advance Rapid HIV-1/2 Antibody Test. The study population includes Howard University Hospital patients who were offered HIV screening over a 12-month period at no cost. Screened patients received immediate test results and, for those patients found to be preliminarily reactive, confirmatory testing and linkage to care were offered. Of the 12836 patients who were offered testing, 7528 (58.6%) consented. Preliminary reactive test results were identified in 176 patients (2.3%). Overall, 45.5% were confirmed, of which 82.5% were confirmed positive. Screening protocol changes have led to 100% confirmation since implementation. Hospital-wide routine HIV screening is feasible and can be implemented effectively and efficiently. The HIV screening campaign instituted at Howard University Hospital identified a substantial number of HIV-positive individuals and provided critical connection to follow-up testing, counseling, and disease management services.

  13. Field performance of clinical case definitions for influenza screening during the 2009 pandemic.

    PubMed

    Chen, Shey-Ying; Chen, Yee-Chun; Chiang, Wen-Chu; Kung, Hsiang-Chi; King, Chwan-Chuen; Lai, Mei-Shu; Chie, Wei-Chu; Chen, Shyr-Chyr; Chen, Wen-Jone; Chang, Shan-Chwen

    2012-11-01

    The aim of this study was to assess the performance of 3 different influenza-like illness (ILI) case definitions, adopted by the European (European-CDC), USA (USA-CDC), and Taiwan Centers for Disease Prevention and Control (Taiwan-CDC), as screening tools for influenza during the 2009 H1N1 pandemic. From August 15 to 30, 2009, all emergency department patients with clinical symptoms or at epidemiologic risk for influenza were enrolled in an observational cohort study. Influenza diagnosis was established by positive rapid influenza diagnostic test or virus isolation. Sensitivity, specificity, positive predictive value, and negative predictive value of the European-, USA, and Taiwan-CDC ILI case definitions for screening were determined. A total of 870 patients were screened during the study period. Rapid influenza diagnostic test was positive in 315 patients, 273 (85.6%) of whom had fever duration less than 72 hours. Virus isolation identified 4 more patients with influenza A initially negative by rapid influenza diagnostic test. The mean (SD) age of these 319 patients was 24.3 (18.1) years. Of the 870 screened patients, 670 (77.0%), 476 (54.7%), and 325 (37.4%) met the European-, USA-, and Taiwan-CDC ILI case definition, respectively. Screening sensitivity was 95%, 77.7%, and 57.7% and specificity was 33.4%, 58.6%, and 74.4%, respectively. Differences in sensitivity and specificity between any 2 of the 3 groups were statistically significant (P < .05). First-line physicians should recognize the advantage and limitation of different ILI case definitions in influenza screening, especially confronted by pandemic or highly pathogenic avian influenza in the future. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Bacterial screening by flow cytometry offers potential for extension of platelet storage: results of 14 months of active surveillance.

    PubMed

    Vollmer, T; Engemann, J; Kleesiek, K; Dreier, J

    2011-06-01

    Bacterial contamination is currently the major infectious hazard of platelet transfusion in developed countries. It has been demonstrated that a significant transfusion risk remains, in particular with older platelet concentrates (PCs). In 2009, the shelf life of PCs was therefore reduced in Germany to 4 days after the day of production according to Vote 38. The aim of the present study was the application and implementation of a recently developed flow cytometry-based rapid screening method (BactiFlow) for bacterial contamination at the end of PC shelf life as a routine in-process control. A total of 472 apheresis-derived PCs were tested using the BactiFlow flow cytometric assay to detect and count bacteria based on esterase activity in viable bacterial cells, while the BacT/Alert automated culture system served as the reference method. The automation potential of the flow cytometric assay was analysed by applying the semi-automated BactiFlow ALS system. An algorithm was developed for use in routine blood bank operations to extend the storage period of PCs. Two of the 472 apheresis PCs tested were positive in culture and identified as Propionibacterium species. One PC was positive for Staphylococcus aureus by both methods. All remaining specimens were tested negative by both methods. Our study demonstrates that routine bacterial testing of PCs was successfully implemented and the established algorithm proved efficient. The BactiFlow flow cytometric assay is the first rapid screening method which is suitable for a routine application combined with a high sensitivity. © 2011 The Authors. Transfusion Medicine © 2011 British Blood Transfusion Society.

  15. An efficient strategy for cell-based antibody library selection using an integrated vector system.

    PubMed

    Yoon, Hyerim; Song, Jin Myung; Ryu, Chun Jeih; Kim, Yeon-Gu; Lee, Eun Kyo; Kang, Sunghyun; Kim, Sang Jick

    2012-09-18

    Cell panning of phage-displayed antibody library is a powerful tool for the development of therapeutic and imaging agents since disease-related cell surface proteins in native complex conformation can be directly targeted. Here, we employed a strategy taking advantage of an integrated vector system which allows rapid conversion of scFv-displaying phage into scFv-Fc format for efficient cell-based scFv library selection on a tetraspanin protein, CD9. A mouse scFv library constructed by using a phagemid vector, pDR-D1 was subjected to cell panning against stable CD9 transfectant, and the scFv repertoire from the enriched phage pool was directly transferred to a mammalian cassette vector, pDR-OriP-Fc1. The resulting constructs enabled transient expression of enough amounts of scFv-Fcs in HEK293E cells, and flow cytometric screening of binders for CD9 transfectant could be performed simply by using the culture supernatants. All three clones selected from the screening showed correct CD9-specificity. They could immunoprecipitate CD9 molecules out of the transfectant cell lysate and correctly stain endogenous CD9 expression on cancer cell membrane. Furthermore, competition assay with a known anti-CD9 monoclonal antibody (mAb) suggested that the binding epitopes of some of them overlap with that of the mAb which resides within the large extracellular loop of CD9. This study demonstrates that scFv-Fc from mammalian transient expression can be chosen as a reliable format for rapid screening and validation in cell-based scFv library selection, and the strategy described here will be applicable to efficient discovery of antibodies to diverse cell-surface targets.

  16. Exploration for the Salinity Tolerance-Related Genes from Xero-Halophyte Atriplex canescens Exploiting Yeast Functional Screening System

    PubMed Central

    Li, Jingtao; Sun, Xinhua; Liu, Yanzhi; Wang, Xueliang; Zhang, Hao; Pan, Hongyu

    2017-01-01

    Plant productivity is limited by salinity stress, both in natural and agricultural systems. Identification of salt stress-related genes from halophyte can provide insights into mechanisms of salt stress tolerance in plants. Atriplex canescens is a xero-halophyte that exhibits optimum growth in the presence of 400 mM NaCl. A cDNA library derived from highly salt-treated A. canescens plants was constructed based on a yeast expression system. A total of 53 transgenic yeast clones expressing enhanced salt tolerance were selected from 105 transformants. Their plasmids were sequenced and the gene characteristics were annotated using a BLASTX search. Retransformation of yeast cells with the selected plasmids conferred salt tolerance to the resulting transformants. The expression patterns of 28 of these stress-related genes were further investigated in A. canescens leaves by quantitative reverse transcription-PCR. In this study, we provided a rapid and robust assay system for large-scale screening of genes for varied abiotic stress tolerance with high efficiency in A. canescens. PMID:29149055

  17. Microphysiological Systems (Tissue Chips) and their Utility for Rare Disease Research.

    PubMed

    Low, Lucie A; Tagle, Danilo A

    2017-01-01

    The scientific and technological development of microphysiological systems (MPS) modeling organs-on-chips, or "tissue chips" (TCs), has progressed rapidly over the past decade. Stem cell research and microfluidic concepts have combined to lead to the development of microphysiological platforms representing an ever-expanding list of different human organ systems. In the context of rare diseases, these bioengineered microfluidics platforms hold promise for modeling of disorders and could prove useful in the screening and efficacy testing of existing therapeutics. Additionally, they have the potential for replacing and refining animal use for new drugs and clinical treatments, or could even act as surrogate human systems for testing of new therapeutics in the future, which could be particularly useful in populations of rare disease sufferers. This chapter will discuss the current state of tissue chip research, and challenges facing the field. Additionally, we will discuss how these devices are being used to model basic cellular and molecular phenotypes of rare diseases, holding promise to provide new tools for understanding of disease pathologies and screening and efficacy testing of potential therapeutics for drug discovery.

  18. Lessons learned from successful Papanicolaou cytology cervical cancer prevention in the Socialist Republic of Vietnam.

    PubMed

    Suba, Eric J; Raab, Stephen S

    2012-04-01

    In 1996, we documented that the burden of cervical cancer in Vietnam was associated with troop movements during the Vietnam War. Subsequently, establishment of Papanicolaou screening in southern Vietnam was associated with reductions in cervical cancer incidence from 29.2/100,000 in 1998 to 16/100,000 in 2003. This is one of the first English-language reports of a real-world cervical cancer prevention effort associated with a decisive impact on health outcomes in a contemporary developing country. if our ideological commitment is to improve health outcomes as rapidly as possible among as many people as possible, then Papanicolaou screening (with or without HPV or visual screening) must be implemented without further delay in any setting where cervical screening is appropriate but unavailable; consideration must be given to HPV vaccination after, rather than before, full coverage of target demographic groups by screening services has been achieved and/or the possibility has been excluded that HPV vaccination may be ineffective for cancer prevention. Competing ideological commitments engender imprudent yet commercially useful alternative strategies prone to decelerate global reductions in mortality by suppressing the more-rapid uptake of less-expensive open-source technology in favor of the less-rapid uptake of more-expensive proprietary technologies with uncertain real-world advantages and unfavorable real-world operational limitations. Global cervical cancer prevention efforts will become more effective if global health leaders, including the Bill & Melinda Gates Foundation, embrace an ideological commitment to improving health outcomes as rapidly as possible among as many people as possible and assimilate the policy implications of that commitment. Copyright © 2011 Wiley-Liss, Inc.

  19. Tailored Lay Health Worker Intervention Improves Breast Cancer Screening Outcomes in Non-Adherent Korean-American Women

    ERIC Educational Resources Information Center

    Han, Hae-Ra; Lee, H.; Kim, M. T.; Kim, K. B.

    2009-01-01

    Despite rapidly increasing incidence rates of breast cancer, recent immigrants such as Korean-American (KA) women report disproportionately lower utilization of screening tests compared with other ethnic groups. Early screening of breast cancer for this population may be greatly facilitated by indigenous lay health workers (LHWs). We conducted an…

  20. Rapid Parallel Screening for Strain Optimization

    DTIC Science & Technology

    2013-08-16

    fermentation yields of industrially relevant biological compounds. Screening of the desired chemicals was completed previously. Microbes that can...reporter, and, 2) a yeast TAR cloning shuttle vector for transferring catabolic clusters to E. coli. 15. SUBJECT TERMS NA 16. SECURITY CLASSIFICATION OF... fermentation yields of industrially relevant biological compounds. Screening of the desired chemicals was completed previously. Microbes that can utilize

  1. Rapid Parallel Screening for Strain Optimization

    DTIC Science & Technology

    2013-05-16

    fermentation yields of industrially relevant biological compounds. Screening of the desired chemicals was completed previously. Microbes that can...reporter, and, 2) a yeast TAR cloning shuttle vector for transferring catabolic clusters to E. coli. 15. SUBJECT TERMS NA 16. SECURITY CLASSIFICATION OF... fermentation yields of industrially relevant biological compounds. Screening of the desired chemicals was completed previously. Microbes that can utilize

  2. The use of a microreactor for rapid screening of the reaction conditions and investigation of the photoluminescence mechanism of carbon dots.

    PubMed

    Lu, Yue; Zhang, Ling; Lin, Hengwei

    2014-04-07

    A microreactor is applied and reported, for the first time, in the field of research of carbon dots (CDs), including rapid screening of the reaction conditions and investigation of the photoluminescence (PL) mechanism. Various carbonaceous precursors and solvents were selected and hundreds of reaction conditions were screened (ca. 15 min on average per condition). Through analyzing the screened conditions, tunable PL emission maxima, from about 330 to 550 nm with respectable PL quantum yields, were achieved. Moreover, the relationship between different developmental stages of the CDs and the PL properties was explored by using the microreactor. The PL emission was observed to be independent of the composition, carbonization extent, and morphology/size of the CDs. This study unambiguously presents that a microreactor could serve as a promising tool for the research of CDs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. eC3—A Modern Telecommunications Matrix for Cervical Cancer Prevention in Zambia

    PubMed Central

    Parham, Groesbeck P.; Mwanahamuntu, Mulindi H.; Pfaendler, Krista S.; Sahasrabuddhe, Vikrant V.; Myung, Daniel; Mkumba, Gracilia; Kapambwe, Sharon; Mwanza, Bianca; Chibwesha, Carla; Hicks, Michael L.; Stringer, Jeffrey S.A.

    2013-01-01

    Objectives Low physician density, undercapacitated laboratory infrastructures, and limited resources are major limitations to the development and implementation of widely accessible cervical cancer prevention programs in sub-Saharan Africa. Materials and Methods We developed a system operated by nonphysician health providers that used widely available and affordable communication technology to create locally adaptable and sustainable public sector cervical cancer prevention program in Zambia, one of the world’s poorest countries. Results Nurses were trained to perform visual inspection with acetic acid aided by digital cervicography using predefined criteria. Electronic digital images (cervigrams) were reviewed with patients, and distance consultation was sought as necessary. Same-visit cryotherapy or referral for further evaluation by a gynecologist was offered. The Zambian system of “electronic cervical cancer control” bypasses many of the historic barriers to the delivery of preventive health care to women in low-resource environments while facilitating monitoring, evaluation, and continued education of primary health care providers, patient education, and medical records documentation. Conclusions The electronic cervical cancer control system uses appropriate technology to bridge the gap between screening and diagnosis, thereby facilitating the conduct of “screen-and-treat” programs. The inherent flexibility of the system lends itself to the integration with future infrastructures using rapid molecular human papillomavirus–based screening approaches and wireless telemedicine communications. PMID:20592550

  4. Development of a novel drug release system, time-controlled explosion system (TES). I. Concept and design.

    PubMed

    Ueda, S; Hata, T; Asakura, S; Yamaguchi, H; Kotani, M; Ueda, Y

    1994-01-01

    A novel controlled drug release system. Time-Controlled Explosion System (TES) has been developed. TES has a four-layered spherical structure, which consists of core, drug, swelling agent and water insoluble polymer membrane. TES is characterized by a rapid drug release with a precisely programmed lag time; i.e. expansion of the swelling agent by water penetrating through the outer membrane, destruction of the membrane by stress due to swelling force and subsequent rapid drug release. For establishing the concept and development strategy, TES was designed using metoprolol and polystyrene balls (size: 3.2 mm in diameter) as a model drug and core particles. Among the polymers screened, low-substituted hydroxypropylcellulose (L-HPC) and ethylcellulose (EC) were selected for a swelling agent and an outer water insoluble membrane, respectively. The release profiles of metoprolol from the system were not affected by the pH of the dissolution media. Lag time was controlled by the thickness of the outer EC membrane; thus, a combination of TES particles possessing different lag times could offer any desired release profile of the model compound, metoprolol.

  5. A prototype software methodology for the rapid evaluation of biomanufacturing process options.

    PubMed

    Chhatre, Sunil; Francis, Richard; O'Donovan, Kieran; Titchener-Hooker, Nigel J; Newcombe, Anthony R; Keshavarz-Moore, Eli

    2007-10-01

    A three-layered simulation methodology is described that rapidly evaluates biomanufacturing process options. In each layer, inferior options are screened out, while more promising candidates are evaluated further in the subsequent, more refined layer, which uses more rigorous models that require more data from time-consuming experimentation. Screening ensures laboratory studies are focused only on options showing the greatest potential. To simplify the screening, outputs of production level, cost and time are combined into a single value using multi-attribute-decision-making techniques. The methodology was illustrated by evaluating alternatives to an FDA (U.S. Food and Drug Administration)-approved process manufacturing rattlesnake antivenom. Currently, antivenom antibodies are recovered from ovine serum by precipitation/centrifugation and proteolyzed before chromatographic purification. Alternatives included increasing the feed volume, replacing centrifugation with microfiltration and replacing precipitation/centrifugation with a Protein G column. The best alternative used a higher feed volume and a Protein G step. By rapidly evaluating the attractiveness of options, the methodology facilitates efficient and cost-effective process development.

  6. Rapid Analysis of Bisphenol A and Its Analogues in Food Packaging Products by Paper Spray Ionization Mass Spectrometry.

    PubMed

    Chen, Shuo; Chang, Quanying; Yin, Kai; He, Qunying; Deng, Yongxiu; Chen, Bo; Liu, Chengbin; Wang, Ying; Wang, Liping

    2017-06-14

    In this study, a paper spray ionization mass spectrometric (PS-MS) method was developed for the rapid in situ screening and simultaneous quantitative analysis of bisphenol A and its analogues, i.e., bisphenol S, bisphenol F, and bisphenol AF, in food packaging products. At the optimal PS-MS conditions, the calibration curves of bisphenols in the range of 1-100 μg/mL were linear. The correlation coefficients were higher than 0.998, and the LODs of the target compounds were 0.1-0.3 μg/mL. After a simple treatment by dichloromethane on the surface, the samples were analyzed by PS-MS in situ for rapid screening without a traditional sample pretreatment procedure, such as powdering, extraction, and enrichment steps. The analytical time of the PS-MS method was less than 1 min. In comparison with conventional HPLC-MS/MS, it was demonstrated that PS-MS was a more effective high-throughput screening and quantitative analysis method.

  7. Prospective Evaluation of Light Scatter Technology Paired with Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Rapid Diagnosis of Urinary Tract Infections

    PubMed Central

    Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P.

    2017-01-01

    ABSTRACT Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. PMID:28356414

  8. Prospective Evaluation of Light Scatter Technology Paired with Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Rapid Diagnosis of Urinary Tract Infections.

    PubMed

    Montgomery, Sandra; Roman, Kiana; Ngyuen, Lan; Cardenas, Ana Maria; Knox, James; Tomaras, Andrew P; Graf, Erin H

    2017-06-01

    Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h. Copyright © 2017 American Society for Microbiology.

  9. Rapid Separation of Bacteria from Blood—Review and Outlook

    PubMed Central

    Alizadeh, Mahsa; Husseini, Ghaleb A.; McClellan, Daniel S.; Buchanan, Clara M.; Bledsoe, Colin G.; Robison, Richard A.; Blanco, Rae; Roeder, Beverly L.; Melville, Madison; Hunter, Alex K.

    2017-01-01

    The high morbidity and mortality rate of bloodstream infections involving antibiotic-resistant bacteria necessitate a rapid identification of the infectious organism and its resistance profile. Traditional methods based on culturing the blood typically require at least 24 h, and genetic amplification by PCR in the presence of blood components has been problematic. The rapid separation of bacteria from blood would facilitate their genetic identification by PCR or other methods so that the proper antibiotic regimen can quickly be selected for the septic patient. Microfluidic systems that separate bacteria from whole blood have been developed, but these are designed to process only microliter quantities of whole blood or only highly diluted blood. However, symptoms of clinical blood infections can be manifest with bacterial burdens perhaps as low as 10 CFU/mL, and thus milliliter quantities of blood must be processed to collect enough bacteria for reliable genetic analysis. This review considers the advantages and shortcomings of various methods to separate bacteria from blood, with emphasis on techniques that can be done in less than 10 min on milliliter-quantities of whole blood. These techniques include filtration, screening, centrifugation, sedimentation, hydrodynamic focusing, chemical capture on surfaces or beads, field-flow fractionation, and dielectrophoresis. Techniques with the most promise include screening, sedimentation, and magnetic bead capture, as they allow large quantities of blood to be processed quickly. Some microfluidic techniques can be scaled up. PMID:27160415

  10. Electrochemical Impedance Immunosensor Based on Self-Assembled Monolayers for Rapid Detection of Escherichia coli O157:H7 with Signal Amplification Using Lectin

    PubMed Central

    Li, Zhanming; Fu, Yingchun; Fang, Weihuan; Li, Yanbin

    2015-01-01

    Escherichia coli O157:H7 is a predominant foodborne pathogen with severe pathogenicity, leading to increasing attention given to rapid and sensitive detection. Herein, we propose an impedance biosensor using new kinds of screen-printed interdigitated microelectrodes (SPIMs) and wheat germ agglutinin (WGA) for signal amplification to detect E. coli O157:H7 with high sensitivity and time-efficiency. The SPIMs integrate the high sensitivity and short response time of the interdigitated electrodes and the low cost of the screen-printed electrodes. Self-assembling of bi-functional 3-dithiobis-(sulfosuccinimidyl-propionate) (DTSP) on the SPIMs was investigated and was proved to be able to improve adsorption quantity and stability of biomaterials. WGA was further adopted to enhance the signal taking advantage of the abundant lectin-binding sites on the bacteria surface. The immunosensor exhibited a detection limit of 102 cfu·mL−1, with a linear detection range from 102 to 107 cfu·mL−1 (r2 = 0.98). The total detection time was less than 1 h, showing its comparable sensitivity and rapid response. Furthermore, the low cost of one SPIM significantly reduced the detection cost of the biosensor. The biosensor may have great promise in food safety analysis and lead to a portable biosensing system for routine monitoring of foodborne pathogens. PMID:26251911

  11. Rapid screening and determination of 11 new psychoactive substances by direct analysis in real time mass spectrometry and liquid chromatography/quadrupole time-of-flight mass spectrometry.

    PubMed

    Nie, Honggang; Li, Xianjiang; Hua, Zhendong; Pan, Wei; Bai, Yanping; Fu, Xiaofang

    2016-08-01

    With the amounts and types of new psychoactive substances (NPSs) increasing rapidly in recent years, an excellent high-throughput method for the analysis of these compounds is urgently needed. In this article, a rapid screening method and a quantitative analysis method for 11 NPSs are described and compared, respectively. A simple direct analysis in real time mass spectrometry (DART-MS) method was developed for the analysis of 11 NPSs including three categories of these substances present on the global market such as four cathinones, one phenylethylamine, and six synthetic cannabinoids. In order to analyze these compounds quantitatively with better accuracy and sensitivity, another rapid analytical method with a low limit of detection (LOD) was also developed using liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry (LC/QTOFMS). The 11 NPSs could be determined within 0.5 min by DART-MS. Furthermore, they could also be separated and determined within 5 min by the LC/QTOFMS method. The two methods both showed good linearity with correlation coefficients (r(2) ) higher than 0.99. The LODs for all these target NPSs by DART-MS and LC/QTOFMS ranged from 5 to 40 ng mL(-1) and 0.1 to 1 ng mL(-1) , respectively. Confiscated samples, named as "music vanilla" and "bath salt", and 11 spiked samples were firstly screened by DART-MS and then determined by LC/QTOFMS. The identification of NPSs in confiscated materials was successfully achieved, and the proposed analytical methodology could offer rapid screening and accurate analysis results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Single Day Construction of Multigene Circuits with 3G Assembly.

    PubMed

    Halleran, Andrew D; Swaminathan, Anandh; Murray, Richard M

    2018-05-18

    The ability to rapidly design, build, and test prototypes is of key importance to every engineering discipline. DNA assembly often serves as a rate limiting step of the prototyping cycle for synthetic biology. Recently developed DNA assembly methods such as isothermal assembly and type IIS restriction enzyme systems take different approaches to accelerate DNA construction. We introduce a hybrid method, Golden Gate-Gibson (3G), that takes advantage of modular part libraries introduced by type IIS restriction enzyme systems and isothermal assembly's ability to build large DNA constructs in single pot reactions. Our method is highly efficient and rapid, facilitating construction of entire multigene circuits in a single day. Additionally, 3G allows generation of variant libraries enabling efficient screening of different possible circuit constructions. We characterize the efficiency and accuracy of 3G assembly for various construct sizes, and demonstrate 3G by characterizing variants of an inducible cell-lysis circuit.

  13. Comprehensive Urine Drug Screen by Gas Chromatography/Mass Spectrometry (GC/MS).

    PubMed

    Ramoo, Bheemraj; Funke, Melissa; Frazee, Clint; Garg, Uttam

    2016-01-01

    Drug screening is an essential component of clinical toxicology laboratory service. Some laboratories use only automated chemistry analyzers for limited screening of drugs of abuse and few other drugs. Other laboratories use a combination of various techniques such as immunoassays, colorimetric tests, and mass spectrometry to provide more detailed comprehensive drug screening. Mass spectrometry, gas or liquid, can screen for hundreds of drugs and is often considered the gold standard for comprehensive drug screening. We describe an efficient and rapid gas chromatography/mass spectrometry (GC/MS) method for comprehensive drug screening in urine which utilizes a liquid-liquid extraction, sample concentration, and analysis by GC/MS.

  14. Mass spectrometric directed system for the continuous-flow synthesis and purification of diphenhydramine.

    PubMed

    Loren, Bradley P; Wleklinski, Michael; Koswara, Andy; Yammine, Kathryn; Hu, Yanyang; Nagy, Zoltan K; Thompson, David H; Cooks, R Graham

    2017-06-01

    A highly integrated approach to the development of a process for the continuous synthesis and purification of diphenhydramine is reported. Mass spectrometry (MS) is utilized throughout the system for on-line reaction monitoring, off-line yield quantitation, and as a reaction screening module that exploits reaction acceleration in charged microdroplets for high throughput route screening. This effort has enabled the discovery and optimization of multiple routes to diphenhydramine in glass microreactors using MS as a process analytical tool (PAT). The ability to rapidly screen conditions in charged microdroplets was used to guide optimization of the process in a microfluidic reactor. A quantitative MS method was developed and used to measure the reaction kinetics. Integration of the continuous-flow reactor/on-line MS methodology with a miniaturized crystallization platform for continuous reaction monitoring and controlled crystallization of diphenhydramine was also achieved. Our findings suggest a robust approach for the continuous manufacture of pharmaceutical drug products, exemplified in the particular case of diphenhydramine, and optimized for efficiency and crystal size, and guided by real-time analytics to produce the agent in a form that is readily adapted to continuous synthesis.

  15. Screening tests for the rapid detection of diarrhetic shellfish toxins in Washington State.

    PubMed

    Eberhart, Bich-Thuy L; Moore, Leslie K; Harrington, Neil; Adams, Nicolaus G; Borchert, Jerry; Trainer, Vera L

    2013-09-30

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test "pre-harvest" shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer's recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters.

  16. Screening Tests for the Rapid Detection of Diarrhetic Shellfish Toxins in Washington State

    PubMed Central

    Eberhart, Bich-Thuy L.; Moore, Leslie K.; Harrington, Neil; Adams, Nicolaus G.; Borchert, Jerry; Trainer, Vera L.

    2013-01-01

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test “pre-harvest” shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer’s recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters. PMID:24084788

  17. Multicolor fluorescent biosensor for multiplexed detection of DNA.

    PubMed

    Hu, Rong; Liu, Tao; Zhang, Xiao-Bing; Huan, Shuang-Yan; Wu, Cuichen; Fu, Ting; Tan, Weihong

    2014-05-20

    Development of efficient methods for highly sensitive and rapid screening of specific oligonucleotide sequences is essential to the early diagnosis of serious diseases. In this work, an aggregated cationic perylene diimide (PDI) derivative was found to efficiently quench the fluorescence emission of a variety of anionic oligonucleotide-labeled fluorophores that emit at wavelengths from the visible to NIR region. This broad-spectrum quencher was then adopted to develop a multicolor biosensor via a label-free approach for multiplexed fluorescent detection of DNA. The aggregated perylene derivative exhibits a very high quenching efficiency on all ssDNA-labeled dyes associated with biosensor detection, having efficiency values of 98.3 ± 0.9%, 97 ± 1.1%, and 98.2 ± 0.6% for FAM, TAMRA, and Cy5, respectively. An exonuclease-assisted autocatalytic target recycling amplification was also integrated into the sensing system. High quenching efficiency combined with autocatalytic target recycling amplification afforded the biosensor with high sensitivity toward target DNA, resulting in a detection limit of 20 pM, which is about 50-fold lower than that of traditional unamplified homogeneous fluorescent assay methods. The quencher did not interfere with the catalytic activity of nuclease, and the biosensor could be manipulated in either preaddition or postaddition manner with similar sensitivity. Moreover, the proposed sensing system allows for simultaneous and multicolor analysis of several oligonucleotides in homogeneous solution, demonstrating its potential application in the rapid screening of multiple biotargets.

  18. [An illustrated guide to dental screening: a school survey].

    PubMed

    Tenenbaum, Annabelle; Sayada, Mélanie; Azogui-Levy, Sylvie

    2017-12-05

    Marked social inequalities in oral health are observed right from early childhood. A mandatory complete health check-up, including dental screening, is organized at school for 6-year-old children. School healthcare professionals are not well trained in dental health. The aim of this study was to assess the relevance of an illustrated guide as a simple and rapid dental screening training tool in order to ensure effective, standardized and reproducible screening. A cross-sectional study was conducted in the context of the dental examination performed as part of the health check-up. Two examiners (Doctor E1 and Nurse E2) were trained in dental screening by means of the illustrated guide. This reference guide, comprising pictures and legends, presents the main oral pathology observed in children. 109 consent forms for oral screening were delivered, and 102 children agreed to participate (93.57%). The sensitivity of detection of tooth decay by examiners E1 and E2 was 81.48% with a specificity of 96%. No correlation was observed between the child's age (+/- 6 years) and correct detection rates. The illustrated guide is an appropriate and rapid tool for dental screening that can improve the quality of dental check-up and increase the number of children detected.

  19. A strategy for rapid production and screening of yeast artificial chromosome libraries.

    PubMed

    Strauss, W M; Jaenisch, E; Jaenisch, R

    1992-01-01

    We describe methods for rapid production and screening of yeast artificial chromosome (YAC) libraries. Utilizing complete restriction digests of mouse genomic DNA for ligations in agarose, a 32,000-clone library was produced and screened in seven weeks. Screening was accomplished by subdividing primary transformation plates into pools of approximately 100 clones which were transferred into a master glycerol stock. These master stocks were used to inoculate liquid cultures to produce culture "pools," and ten pools of 100 clones were then combined to yield superpools of 1,000 clones. Both pool and superpool DNA was screened by polymerase chain reaction (PCR) and positive pools representing 100 clones were then plated on selective medium and screened by in situ hybridization. Screening by the two tiered PCR assay and by in situ hybridization was completed in 4-5 days. Utilizing this methodology we have isolated a 150 kb clone spanning the alpha 1(I) collagen (Col1a1) gene as well as 40 kb clones from the Hox-2 locus. To characterize the representation of the YAC library, the size distribution of genomic Sal I fragments was compared to that of clones picked at random from the library. The results demonstrate significant biasing of the cloned fragment distribution, resulting in a loss of representation for larger fragments.

  20. Advanced Millimeter-Wave Security Portal Imaging Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheen, David M.; Bernacki, Bruce E.; McMakin, Douglas L.

    2012-04-01

    Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.

  1. An improved ternary vector system for Agrobacterium-mediated rapid maize transformation.

    PubMed

    Anand, Ajith; Bass, Steven H; Wu, Emily; Wang, Ning; McBride, Kevin E; Annaluru, Narayana; Miller, Michael; Hua, Mo; Jones, Todd J

    2018-05-01

    A simple and versatile ternary vector system that utilizes improved accessory plasmids for rapid maize transformation is described. This system facilitates high-throughput vector construction and plant transformation. The super binary plasmid pSB1 is a mainstay of maize transformation. However, the large size of the base vector makes it challenging to clone, the process of co-integration is cumbersome and inefficient, and some Agrobacterium strains are known to give rise to spontaneous mutants resistant to tetracycline. These limitations present substantial barriers to high throughput vector construction. Here we describe a smaller, simpler and versatile ternary vector system for maize transformation that utilizes improved accessory plasmids requiring no co-integration step. In addition, the newly described accessory plasmids have restored virulence genes found to be defective in pSB1, as well as added virulence genes. Testing of different configurations of the accessory plasmids in combination with T-DNA binary vector as ternary vectors nearly doubles both the raw transformation frequency and the number of transformation events of usable quality in difficult-to-transform maize inbreds. The newly described ternary vectors enabled the development of a rapid maize transformation method for elite inbreds. This vector system facilitated screening different origins of replication on the accessory plasmid and T-DNA vector, and four combinations were identified that have high (86-103%) raw transformation frequency in an elite maize inbred.

  2. Comparative Normal/Failing Rat Myocardium Cell Membrane Chromatographic Analysis System for Screening Specific Components That Counteract Doxorubicin-Induced Heart Failure from Acontium carmichaeli

    PubMed Central

    2015-01-01

    Cell membrane chromatography (CMC) derived from pathological tissues is ideal for screening specific components acting on specific diseases from complex medicines owing to the maximum simulation of in vivo drug-receptor interactions. However, there are no pathological tissue-derived CMC models that have ever been developed, as well as no visualized affinity comparison of potential active components between normal and pathological CMC columns. In this study, a novel comparative normal/failing rat myocardium CMC analysis system based on online column selection and comprehensive two-dimensional (2D) chromatography/monolithic column/time-of-flight mass spectrometry was developed for parallel comparison of the chromatographic behaviors on both normal and pathological CMC columns, as well as rapid screening of the specific therapeutic agents that counteract doxorubicin (DOX)-induced heart failure from Acontium carmichaeli (Fuzi). In total, 16 potential active alkaloid components with similar structures in Fuzi were retained on both normal and failing myocardium CMC models. Most of them had obvious decreases of affinities on failing myocardium CMC compared with normal CMC model except for four components, talatizamine (TALA), 14-acetyl-TALA, hetisine, and 14-benzoylneoline. One compound TALA with the highest affinity was isolated for further in vitro pharmacodynamic validation and target identification to validate the screen results. Voltage-dependent K+ channel was confirmed as a binding target of TALA and 14-acetyl-TALA with high affinities. The online high throughput comparative CMC analysis method is suitable for screening specific active components from herbal medicines by increasing the specificity of screened results and can also be applied to other biological chromatography models. PMID:24731167

  3. Variables in screening for resistance to Huanglongbing

    USDA-ARS?s Scientific Manuscript database

    A series of experiments were initiated to assess factors which might permit more rapid screening for huanglongbing (HLB) resistance, using sweet orange in all experiments and Carrizo and/or Temple as sources of resistance/tolerance. Numerous researchers working on huanglongbing provided observations...

  4. Detecting Developmental Neurotoxicants Using Zebrafish Embryos

    EPA Science Inventory

    As part of EPA’s program on the screening and prioritization of chemicals for developmental neurotoxicity, a rapid, cost-effective in vivo vertebrate screen is being developed using an alternative species approach. Zebrafish (Danio rerio), a small freshwater fish with external f...

  5. Rapid identification of Keap1-Nrf2 small-molecule inhibitors through structure-based virtual screening and hit-based substructure search.

    PubMed

    Zhuang, Chunlin; Narayanapillai, Sreekanth; Zhang, Wannian; Sham, Yuk Yin; Xing, Chengguo

    2014-02-13

    In this study, rapid structure-based virtual screening and hit-based substructure search were utilized to identify small molecules that disrupt the interaction of Keap1-Nrf2. Special emphasis was placed toward maximizing the exploration of chemical diversity of the initial hits while economically establishing informative structure-activity relationship (SAR) of novel scaffolds. Our most potent noncovalent inhibitor exhibits three times improved cellular activation in Nrf2 activation than the most active noncovalent Keap1 inhibitor known to date.

  6. Blood-brain-barrier spheroids as an in vitro screening platform for brain-penetrating agents.

    PubMed

    Cho, Choi-Fong; Wolfe, Justin M; Fadzen, Colin M; Calligaris, David; Hornburg, Kalvis; Chiocca, E Antonio; Agar, Nathalie Y R; Pentelute, Bradley L; Lawler, Sean E

    2017-06-06

    Culture-based blood-brain barrier (BBB) models are crucial tools to enable rapid screening of brain-penetrating drugs. However, reproducibility of in vitro barrier properties and permeability remain as major challenges. Here, we report that self-assembling multicellular BBB spheroids display reproducible BBB features and functions. The spheroid core is comprised mainly of astrocytes, while brain endothelial cells and pericytes encase the surface, acting as a barrier that regulates transport of molecules. The spheroid surface exhibits high expression of tight junction proteins, VEGF-dependent permeability, efflux pump activity and receptor-mediated transcytosis of angiopep-2. In contrast, the transwell co-culture system displays comparatively low levels of BBB regulatory proteins, and is unable to discriminate between the transport of angiopep-2 and a control peptide. Finally, we have utilized the BBB spheroids to screen and identify BBB-penetrant cell-penetrating peptides (CPPs). This robust in vitro BBB model could serve as a valuable next-generation platform for expediting the development of CNS therapeutics.

  7. Kinetic assay for high-throughput screening of in vitro transthyretin amyloid fibrillogenesis inhibitors.

    PubMed

    Dolado, Ignacio; Nieto, Joan; Saraiva, Maria João M; Arsequell, Gemma; Valencia, Gregori; Planas, Antoni

    2005-01-01

    Stabilization of tetrameric transthyretin (TTR) by binding of small ligands is a current strategy aimed at inhibiting amyloid fibrillogenesis in transthyretin-associated pathologies, such as senile systemic amyloidosis (SSA) and familial amyloidotic polyneuropathy (FAP). A kinetic assay is developed for rapid evaluation of compounds as potential in vitro inhibitors in a high-throughput screening format. It is based on monitoring the time-dependent increase of absorbance due to turbidity occurring by acid-induced protein aggregation. The method uses the highly amyloidogenic Y78F mutant of human transthyretin (heterogously expressed in Escherichia coli cells). Initial rates of protein aggregation at different inhibitor concentrations follow a monoexponential dose-response curve from which inhibition parameters are calculated. For the assay development, thyroid hormones and nonsteroidal antiinflamatory drugs were chosen among other reference compounds. Some of them are already known to be in vitro inhibitors of TTR amyloidogenesis. Analysis time is optimized to last 1.5 h, and the method is implemented in microtiter plates for screening of libraries of potential fibrillogenesis inhibitors.

  8. Dynamic amphiphile libraries to screen for the "fragrant" delivery of siRNA into HeLa cells and human primary fibroblasts.

    PubMed

    Gehin, Charlotte; Montenegro, Javier; Bang, Eun-Kyoung; Cajaraville, Ana; Takayama, Shota; Hirose, Hisaaki; Futaki, Shiroh; Matile, Stefan; Riezman, Howard

    2013-06-26

    Dynamic amphiphiles are amphiphiles with dynamic covalent bridges between their hydrophilic heads and their hydrophobic tails. Their usefulness to activate ion transporters, for odorant release, and for differential sensing of odorants and perfumes, has been demonstrated recently. Here, we report that the same "fragrant" dynamic amphiphiles are ideal to screen for new siRNA transfection agents. The advantages of this approach include rapid access to fairly large libraries of complex structures, and possible transformation en route to assist uptake and minimize toxicity. We report single-component systems that exceed the best commercially available multicomponent cocktails with regard to both efficiency and velocity of EGFP knockdown in HeLa cells. In human primary fibroblasts, siRNA-mediated enzyme knockdown nearly doubled from >30% for Lipofectamine to >60% for our best hit. The identified structures were predictable neither from literature nor from results in fluorogenic vesicles and thus support the importance of conceptually innovative screening approaches.

  9. Digital Breast Tomosynthesis and the Challenges of Implementing an Emerging Breast Cancer Screening Technology Into Clinical Practice.

    PubMed

    Lee, Christoph I; Lehman, Constance D

    2016-11-01

    Emerging imaging technologies, including digital breast tomosynthesis, have the potential to transform breast cancer screening. However, the rapid adoption of these new technologies outpaces the evidence of their clinical and cost-effectiveness. The authors describe the forces driving the rapid diffusion of tomosynthesis into clinical practice, comparing it with the rapid diffusion of digital mammography shortly after its introduction. They outline the potential positive and negative effects that adoption can have on imaging workflow and describe the practice management challenges when incorporating tomosynthesis. The authors also provide recommendations for collecting evidence supporting the development of policies and best practices. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Metabolic Toxicity Screening Using Electrochemiluminescence Arrays Coupled with Enzyme-DNA Biocolloid Reactors and Liquid Chromatography-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Hvastkovs, Eli, G.; Schenkman, John B.; Rusling, James, F.

    2012-07-01

    New chemicals or drugs must be guaranteed safe before they can be marketed. Despite widespread use of bioassay panels for toxicity prediction, products that are toxic to a subset of the population often are not identified until clinical trials. This article reviews new array methodologies based on enzyme/DNA films that form and identify DNA-reactive metabolites that are indicators of potentially genotoxic species. This molecularly based methodology is designed in a rapid screening array that utilizes electrochemiluminescence (ECL) to detect metabolite-DNA reactions, as well as biocolloid reactors that provide the DNA adducts and metabolites for liquid chromatography-mass spectrometry (LC-MS) analysis. ECL arrays provide rapid toxicity screening, and the biocolloid reactor LC-MS approach provides a valuable follow-up on structure, identification, and formation rates of DNA adducts for toxicity hits from the ECL array screening. Specific examples using this strategy are discussed. Integration of high-throughput versions of these toxicity-screening methods with existing drug toxicity bioassays should allow for better human toxicity prediction as well as more informed decision making regarding new chemical and drug candidates.

  11. Prevention of Congenital Syphilis Through Antenatal Screenings in Lusaka, Zambia: A Systematic Review.

    PubMed

    Akhtar, Faisal; Rehman, Sabah

    2018-01-16

    Congenital syphilis is one of the preventable diseases caused by the gram-negative bacteria Treponema pallidum; yet, it imposes a serious global health and economic burden, with more than half of the cases resulting in serious adverse outcomes, including infant mortality. Mother-to-child transmission (MTCT) of syphilis is estimated at 3.6 million adjusted life years (DALYs) and around $309 million in medical costs. In 2006, an estimated 9.7 million children of age less than five years died in developing countries; almost four million were neonatal deaths. There were 3.2 million stillbirths globally, among whom 95% were in the developing countries. In sub-Saharan Africa, there is an estimated 2.7% (0.1%-10.3%) of pregnant women infected with syphilis, representing more than 900,000 pregnancies at risk each year. There were many non-specific and specific diagnostic tests used in the past, which required laboratory equipment and electricity, but there are many newer tests available now that provide rapid results with high sensitivity and specificity, e.g., the immunochromatographic strip (ICS) and rapid syphilis tests (RST). Early syphilis can be completely eliminated with a single injection of penicillin, which is readily available, cheap, and highly effective, and treating pregnant women with penicillin is 98% effective at preventing congenital syphilis. Targeting women at a high risk of having syphilis makes universal screening in antenatal programs the most efficacious way to prevent syphilis-associated morbidity and mortality. The potential for a program to prevent congenital syphilis in the perinatal, neonatal, and postnatal periods is evident. While considering resource allocation to child survival programs in areas where the prevalence of syphilis is high, officials need to include antenatal syphilis screening, using rapid tests and treatment at the first contact of the mother with the health care system. In countries like Zambia and other resource-limited settings, a same-day test and treatment with penicillin should be prioritized to achieve the goal of eliminating congenital syphilis. Eliminating MTCT of syphilis through screening and treatment in antenatal care (ANC) is highly cost-effective in a wide range of settings, especially in countries with a high prevalence.

  12. Prevention of Congenital Syphilis Through Antenatal Screenings in Lusaka, Zambia: A Systematic Review

    PubMed Central

    Rehman, Sabah

    2018-01-01

    Congenital syphilis is one of the preventable diseases caused by the gram-negative bacteria Treponema pallidum; yet, it imposes a serious global health and economic burden, with more than half of the cases resulting in serious adverse outcomes, including infant mortality. Mother-to-child transmission (MTCT) of syphilis is estimated at 3.6 million adjusted life years (DALYs) and around $309 million in medical costs. In 2006, an estimated 9.7 million children of age less than five years died in developing countries; almost four million were neonatal deaths. There were 3.2 million stillbirths globally, among whom 95% were in the developing countries. In sub-Saharan Africa, there is an estimated 2.7% (0.1%-10.3%) of pregnant women infected with syphilis, representing more than 900,000 pregnancies at risk each year. There were many non-specific and specific diagnostic tests used in the past, which required laboratory equipment and electricity, but there are many newer tests available now that provide rapid results with high sensitivity and specificity, e.g., the immunochromatographic strip (ICS) and rapid syphilis tests (RST). Early syphilis can be completely eliminated with a single injection of penicillin, which is readily available, cheap, and highly effective, and treating pregnant women with penicillin is 98% effective at preventing congenital syphilis. Targeting women at a high risk of having syphilis makes universal screening in antenatal programs the most efficacious way to prevent syphilis-associated morbidity and mortality. The potential for a program to prevent congenital syphilis in the perinatal, neonatal, and postnatal periods is evident. While considering resource allocation to child survival programs in areas where the prevalence of syphilis is high, officials need to include antenatal syphilis screening, using rapid tests and treatment at the first contact of the mother with the health care system. In countries like Zambia and other resource-limited settings, a same-day test and treatment with penicillin should be prioritized to achieve the goal of eliminating congenital syphilis. Eliminating MTCT of syphilis through screening and treatment in antenatal care (ANC) is highly cost-effective in a wide range of settings, especially in countries with a high prevalence. PMID:29560291

  13. A comprehensive screening platform for aerosolizable protein formulations for intranasal and pulmonary drug delivery.

    PubMed

    Röhm, Martina; Carle, Stefan; Maigler, Frank; Flamm, Johannes; Kramer, Viktoria; Mavoungou, Chrystelle; Schmid, Otmar; Schindowski, Katharina

    2017-10-30

    Aerosolized administration of biopharmaceuticals to the airways is a promising route for nasal and pulmonary drug delivery, but - in contrast to small molecules - little is known about the effects of aerosolization on safety and efficacy of biopharmaceuticals. Proteins are sensitive against aerosolization-associated shear stress. Tailored formulations can shield proteins and enhance permeation, but formulation development requires extensive screening approaches. Thus, the aim of this study was to develop a cell-based in vitro technology platform that includes screening of protein quality after aerosolization and transepithelial permeation. For efficient screening, a previously published aerosolization-surrogate assay was used in a design of experiments approach to screen suitable formulations for an IgG and its antigen-binding fragment (Fab) as exemplary biopharmaceuticals. Efficient, dose-controlled aerosol-cell delivery was performed with the ALICE-CLOUD system containing RPMI 2650 epithelial cells at the air-liquid interface. We could demonstrate that our technology platform allows for rapid and efficient screening of formulations consisting of different excipients (here: arginine, cyclodextrin, polysorbate, sorbitol, and trehalose) to minimize aerosolization-induced protein aggregation and maximize permeation through an in vitro epithelial cell barrier. Formulations reduced aggregation of native Fab and IgG relative to vehicle up to 50% and enhanced transepithelial permeation rate up to 2.8-fold. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  14. An Efficient and Rapid Method to Monitor the Oxidative Degradation of Protein Pharmaceuticals: Probing Tyrosine Oxidation with Fluorogenic Derivatization.

    PubMed

    Bommana, Rupesh; Mozziconacci, Olivier; John Wang, Y; Schöneich, Christian

    2017-07-01

    The loss of potency of protein therapeutics can be linked to the oxidation of specific amino acid residues leading to a great variety of oxidative modifications. The comprehensive identification of these oxidative modifications requires high-resolution mass spectrometry analysis, which requires time and expensive resources. Here, we propose a fluorogenic derivatization method of oxidized Tyr and Phe yielding benzoxazole derivatives, as an orthogonal technique for the rapid screening of protein oxidation. Four model proteins, IgG1, human growth hormone (hGH), insulin and bovine serum albumin (BSA) were exposed to oxidation via peroxyl radicals and metal-catalyzed reactions and efficiently screened by fluorogenic derivatization of Tyr and Phe oxidation products. Complementary LC-MS analysis was done to identify the extent of methionine oxidation in oxidized proteins. The Fluorogenic derivatization technique can easily be adapted to a 96-well plate, in which several protein formulations can be screened in short time. Representatively for hGH, we show that the formation of benzoxazole parallels the oxidation of Met to methionine sulfoxide which enables estimation of Met oxidation by just recording the fluorescence. Our rapid fluorescence based screening allows for the fast comparison of the stability of multiple formulations.

  15. Development and validation of an oxygen dissociation assay, a screening platform for discovering, and characterizing hemoglobin-oxygen affinity modifiers.

    PubMed

    Patel, Mira P; Siu, Vincent; Silva-Garcia, Abel; Xu, Qing; Li, Zhe; Oksenberg, Donna

    2018-01-01

    Hemoglobin (Hb) is a critical molecule necessary for all vertebrates to maintain aerobic metabolism. Hb-oxygen (O 2 ) affinity modifiers have been studied to address various diseases including sickle cell disease, hypoxemia, tumor hypoxia, and wound healing. However, drug development of exogenous Hb modifiers has been hindered by the lack of a technique to rapidly screen compounds for their ability to alter Hb-O 2 affinity. We have developed a novel screening assay based upon the spectral changes observed during Hb deoxygenation and termed it the oxygen dissociation assay (ODA). ODA allows for the quantitation of oxygenated Hb at given time points during Hb deoxygenation on a 96-well plate. This assay was validated by comparing the ability of 500 Hb modifiers to alter the Hb-O 2 affinity in the ODA vs the oxygen equilibrium curves obtained using the industry standard Hemox Analyzer instrument. A correlation ( R 2 ) of 0.7 indicated that the ODA has the potential to screen and identify potent exogenous Hb modifiers. In addition, it allows for concurrent comparison of compounds, concentrations, buffers, or pHs on the level of Hb oxygenation. With a cost-effective, simple, rapid, and highly adaptable assay, the ODA will allow researchers to rapidly characterize Hb-O 2 affinity modifiers.

  16. A reporter system for replication-competent gammaretroviruses: the inGluc-MLV-DERSE assay

    PubMed Central

    Aloia, Amanda L.; Duffy, Lisa; Pak, Vladimir; Lee, KyeongEun; Sanchez-Martinez, Silvia; Derse, David; Heidecker, Gisela; Cornetta, Kenneth; Rein, Alan

    2012-01-01

    While novel retroviral vectors for use in gene-therapy products are reducing the potential for formation of replication-competent retrovirus (RCR), it remains crucial to screen products for RCR for both research and clinical purposes. For clinical grade gammaretrovirus-based vectors, RCR screening is achieved by an extended S+L− or marker rescue assay, while standard methods for replication-competent lentivirus detection are still in development. In this report, we describe a rapid and sensitive method for replication-competent gammaretrovirus detection. We used this assay to detect three members of the gammaretrovirus family and compared the sensitivity of our assay with well-established methods for retrovirus detection, including the extended S+L− assay. Results presented here demonstrate that this assay should be useful for gene-therapy product testing. PMID:22402321

  17. Biocontrol and Rapid Detection of Food-Borne Pathogens Using Bacteriophages and Endolysins

    PubMed Central

    Bai, Jaewoo; Kim, You-Tae; Ryu, Sangryeol; Lee, Ju-Hoon

    2016-01-01

    Bacteriophages have been suggested as natural food preservatives as well as rapid detection materials for food-borne pathogens in various foods. Since Listeria monocytogenes-targeting phage cocktail (ListShield) was approved for applications in foods, numerous phages have been screened and experimentally characterized for phage applications in foods. A single phage and phage cocktail treatments to various foods contaminated with food-borne pathogens including E. coli O157:H7, Salmonella enterica, Campylobacter jejuni, Listeria monocytogenes, Staphylococcus aureus, Cronobacter sakazakii, and Vibrio spp. revealed that they have great potential to control various food-borne pathogens and may be alternative for conventional food preservatives. In addition, phage-derived endolysins with high host specificity and host lysis activities may be preferred to food applications rather than phages. For rapid detection of food-borne pathogens, cell-wall binding domains (CBDs) from endolysins have been suggested due to their high host-specific binding. Fluorescence-tagged CBDs have been successfully evaluated and suggested to be alternative materials of expensive antibodies for various detection applications. Most recently, reporter phage systems have been developed and tested to confirm their usability and accuracy for specific detection. These systems revealed some advantages like rapid detection of only viable pathogenic cells without interference by food components in a very short reaction time, suggesting that these systems may be suitable for monitoring of pathogens in foods. Consequently, phage is the next-generation biocontrol agent as well as rapid detection tool to confirm and even identify the food-borne pathogens present in various foods. PMID:27092128

  18. Dietary screening tool identifies nutritional risk in older adults123

    PubMed Central

    Miller, Paige E; Mitchell, Diane C; Hartman, Terryl J; Lawrence, Frank R; Sempos, Christopher T; Smiciklas-Wright, Helen

    2009-01-01

    Background: No rapid methods exist for screening overall dietary intakes in older adults. Objective: The purpose of this study was to develop and evaluate a scoring system for a diet screening tool to identify nutritional risk in community-dwelling older adults. Design: This cross-sectional study in older adults (n = 204) who reside in rural areas examined nutrition status by using an in-person interview, biochemical measures, and four 24-h recalls that included the use of dietary supplements. Results: The dietary screening tool was able to characterize 3 levels of nutritional risk: at risk, possible risk, and not at risk. Individuals classified as at nutritional risk had significantly lower indicators of diet quality (Healthy Eating Index and Mean Adequacy Ratio) and intakes of protein, most micronutrients, dietary fiber, fruit, and vegetables. The at-risk group had higher intakes of fats and oils and refined grains. The at-risk group also had the lowest serum vitamin B-12, folate, β-cryptoxanthin, lutein, and zeaxanthin concentrations. The not-at-nutritional-risk group had significantly higher lycopene and β-carotene and lower homocysteine and methylmalonic acid concentrations. Conclusion: The dietary screening tool is a simple and practical tool that can help to detect nutritional risk in older adults. PMID:19458013

  19. NHMA screening and brief intervention toolkit for the Hispanic patient

    DOT National Transportation Integrated Search

    2008-07-01

    Alcohol consumption is the third leading cause of death in the Unites States and costs over $148 billion each year.1 Studies have shown that rapid, accurate alcohol screening instruments can detect alcohol problems in primary care settings and can po...

  20. CHROMIUM ELECTROANALYSIS AT SCREEN PRINTED ELECTRODE MODIFIED BY THIN FILMS OF NICKEL

    EPA Science Inventory

    A rapid and potentially cost-effective electrochemical method is reported for analysis of chromium (VI) and Chromium(III) using a nickel modified screen printed carbon ink electrode. Electrochemical characteristics of nickel modified electrode as well voltammetric behavior f...

  1. Improved design of electrophoretic equipment for rapid sickle-cell-anemia screening

    NASA Technical Reports Server (NTRS)

    Reddick, J. M.; Hirsch, I.

    1974-01-01

    Effective mass screening may be accomplished by modifying existing electrophoretic equipment in conjunction with multisample applicator used with cellulose-acetate-matrix test paper. Using this method, approximately 20 to 25 samples can undergo electrophoresis in 5 to 6 minutes.

  2. Multi-tiered Approach to Development of Increased Throughput Assay Models to Assess Endocrine-Disrupting Activity of Chemicals

    EPA Science Inventory

    Screening for endocrine-disrupting chemicals (EDCs) requires sensitive, scalable assays. Current high-throughput screening (HTPS) approaches for estrogenic and androgenic activity yield rapid results, but many are not sensitive to physiological hormone concentrations, suggesting ...

  3. Screening guide for rapid assessment of liquefaction hazard at highway bridge sites

    DOT National Transportation Integrated Search

    1998-06-16

    As an aid to seismic hazard assessment, this report provides a "screening guide" for systematic evaluation of liquefactin hazard at bridge sites and a guide for prioritizing sites for further investigation or mitigation. The guide presents a systemat...

  4. High-throughput screening of chromatographic separations: IV. Ion-exchange.

    PubMed

    Kelley, Brian D; Switzer, Mary; Bastek, Patrick; Kramarczyk, Jack F; Molnar, Kathleen; Yu, Tianning; Coffman, Jon

    2008-08-01

    Ion-exchange (IEX) chromatography steps are widely applied in protein purification processes because of their high capacity, selectivity, robust operation, and well-understood principles. Optimization of IEX steps typically involves resin screening and selection of the pH and counterion concentrations of the load, wash, and elution steps. Time and material constraints associated with operating laboratory columns often preclude evaluating more than 20-50 conditions during early stages of process development. To overcome this limitation, a high-throughput screening (HTS) system employing a robotic liquid handling system and 96-well filterplates was used to evaluate various operating conditions for IEX steps for monoclonal antibody (mAb) purification. A screening study for an adsorptive cation-exchange step evaluated eight different resins. Sodium chloride concentrations defining the operating boundaries of product binding and elution were established at four different pH levels for each resin. Adsorption isotherms were measured for 24 different pH and salt combinations for a single resin. An anion-exchange flowthrough step was then examined, generating data on mAb adsorption for 48 different combinations of pH and counterion concentration for three different resins. The mAb partition coefficients were calculated and used to estimate the characteristic charge of the resin-protein interaction. Host cell protein and residual Protein A impurity levels were also measured, providing information on selectivity within this operating window. The HTS system shows promise for accelerating process development of IEX steps, enabling rapid acquisition of large datasets addressing the performance of the chromatography step under many different operating conditions. (c) 2008 Wiley Periodicals, Inc.

  5. Modeling the Impact of School-based Universal Depression Screening on Additional Service Capacity Needs: A System Dynamics Approach

    PubMed Central

    Lyon, Aaron R.; Maras, Melissa A.; Pate, Christina M.; Igusa, Takeru; Stoep, Ann Vander

    2016-01-01

    Although it is widely known that the occurrence of depression increases over the course of adolescence, symptoms of mood disorders frequently go undetected. While schools are viable settings for conducting universal screening to systematically identify students in need of services for common health conditions, particularly those that adversely affect school performance, few school districts routinely screen their students for depression. Among the most commonly referenced barriers are concerns that the number of students identified may exceed schools’ service delivery capacities, but few studies have evaluated this concern systematically. System dynamics (SD) modeling may prove a useful approach for answering questions of this sort. The goal of the current paper is therefore to demonstrate how SD modeling can be applied to inform implementation decisions in communities. In our demonstration, we used SD modeling to estimate the additional service demand generated by universal depression screening in a typical high school. We then simulated the effects of implementing “compensatory approaches” designed to address anticipated increases in service need through (1) the allocation of additional staff time and (2) improvements in the effectiveness of mental health interventions. Results support the ability of screening to facilitate more rapid entry into services and suggest that improving the effectiveness of mental health services for students with depression via the implementation of an evidence-based treatment protocol may have a limited impact on overall recovery rates and service availability. In our example, the SD approach proved useful in informing systems’ decision-making about the adoption of a new school mental health service. PMID:25601192

  6. Risk factors for sensorineural hearing loss in children.

    PubMed

    Núñez-Batalla, Faustino; Trinidad-Ramos, Germán; Sequí-Canet, José Miguel; Alzina De Aguilar, Valentín; Jáudenes-Casaubón, Carmen

    2012-01-01

    In the last decade, tremendous progress has been made very rapidly in the development of Early Hearing Detection and Intervention (EHDI) systems as a major public health initiative. The percentage of infants screened annually in Spain has increased significantly since the EHDI systems have expanded to all autonomic regions. Historically, high risk indicators have been used for the identification of infants who should receive audiological evaluation but who live in geographic locations where universal hearing screening is not yet available, to help identify infants who pass neonatal screening but are at risk of developing delayed-onset hearing loss and to identify infants who may have passed neonatal screening but have mild forms of permanent hearing loss. In this review, the standard risk factors for hearing loss are analysed and the risk factors known to be associated with late onset or progressive hearing loss are identified. The recommendation for infants with a risk factor that may be considered as low risk is to perform at least one audiology assessment by 24-30 months. In contrast, for an infant with risk factors known to be associated with late onset or progressive hearing loss (such as cytomegalovirus infection or family history), early and more frequent assessment is appropriate. All infants should have an objective standardised screening of global development with a validated assessment tool at 9, 18 and 24-30 months of age or at any time if the health care professional or the family is concerned. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  7. Step-by-step guide to building an inexpensive 3D printed motorized positioning stage for automated high-content screening microscopy.

    PubMed

    Schneidereit, Dominik; Kraus, Larissa; Meier, Jochen C; Friedrich, Oliver; Gilbert, Daniel F

    2017-06-15

    High-content screening microscopy relies on automation infrastructure that is typically proprietary, non-customizable, costly and requires a high level of skill to use and maintain. The increasing availability of rapid prototyping technology makes it possible to quickly engineer alternatives to conventional automation infrastructure that are low-cost and user-friendly. Here, we describe a 3D printed inexpensive open source and scalable motorized positioning stage for automated high-content screening microscopy and provide detailed step-by-step instructions to re-building the device, including a comprehensive parts list, 3D design files in STEP (Standard for the Exchange of Product model data) and STL (Standard Tessellation Language) format, electronic circuits and wiring diagrams as well as software code. System assembly including 3D printing requires approx. 30h. The fully assembled device is light-weight (1.1kg), small (33×20×8cm) and extremely low-cost (approx. EUR 250). We describe positioning characteristics of the stage, including spatial resolution, accuracy and repeatability, compare imaging data generated with our device to data obtained using a commercially available microplate reader, demonstrate its suitability to high-content microscopy in 96-well high-throughput screening format and validate its applicability to automated functional Cl - - and Ca 2+ -imaging with recombinant HEK293 cells as a model system. A time-lapse video of the stage during operation and as part of a custom assembled screening robot can be found at https://vimeo.com/158813199. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  8. High content analysis platform for optimization of lipid mediated CRISPR-Cas9 delivery strategies in human cells.

    PubMed

    Steyer, Benjamin; Carlson-Stevermer, Jared; Angenent-Mari, Nicolas; Khalil, Andrew; Harkness, Ty; Saha, Krishanu

    2016-04-01

    Non-viral gene-editing of human cells using the CRISPR-Cas9 system requires optimized delivery of multiple components. Both the Cas9 endonuclease and a single guide RNA, that defines the genomic target, need to be present and co-localized within the nucleus for efficient gene-editing to occur. This work describes a new high-throughput screening platform for the optimization of CRISPR-Cas9 delivery strategies. By exploiting high content image analysis and microcontact printed plates, multi-parametric gene-editing outcome data from hundreds to thousands of isolated cell populations can be screened simultaneously. Employing this platform, we systematically screened four commercially available cationic lipid transfection materials with a range of RNAs encoding the CRISPR-Cas9 system. Analysis of Cas9 expression and editing of a fluorescent mCherry reporter transgene within human embryonic kidney cells was monitored over several days after transfection. Design of experiments analysis enabled rigorous evaluation of delivery materials and RNA concentration conditions. The results of this analysis indicated that the concentration and identity of transfection material have significantly greater effect on gene-editing than ratio or total amount of RNA. Cell subpopulation analysis on microcontact printed plates, further revealed that low cell number and high Cas9 expression, 24h after CRISPR-Cas9 delivery, were strong predictors of gene-editing outcomes. These results suggest design principles for the development of materials and transfection strategies with lipid-based materials. This platform could be applied to rapidly optimize materials for gene-editing in a variety of cell/tissue types in order to advance genomic medicine, regenerative biology and drug discovery. CRISPR-Cas9 is a new gene-editing technology for "genome surgery" that is anticipated to treat genetic diseases. This technology uses multiple components of the Cas9 system to cut out disease-causing mutations in the human genome and precisely suture in therapeutic sequences. Biomaterials based delivery strategies could help transition these technologies to the clinic. The design space for materials based delivery strategies is vast and optimization is essential to ensuring the safety and efficacy of these treatments. Therefore, new methods are required to rapidly and systematically screen gene-editing efficacy in human cells. This work utilizes an innovative platform to generate and screen many formulations of synthetic biomaterials and components of the CRISPR-Cas9 system in parallel. On this platform, we watch genome surgery in action using high content image analysis. These capabilities enabled us to identify formulation parameters for Cas9-material complexes that can optimize gene-editing in a specific human cell type. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Rapid screening of illicit additives in weight loss dietary supplements with desorption corona beam ionisation (DCBI) mass spectrometry.

    PubMed

    Wang, H; Wu, Y; Zhao, Y; Sun, W; Ding, L; Guo, B; Chen, B

    2012-08-01

    Desorption corona beam ionisation (DCBI), the relatively novel ambient mass spectrometry (MS) technique, was utilised to screen for illicit additives in weight-loss food. The five usually abused chemicals - fenfluramine, N-di-desmethyl sibutramine, N-mono-desmethyl sibutramine, sibutramine and phenolphthalein - were detected with the proposed DCBI-MS method. Fast single-sample and high-throughput analysis was demonstrated. Semi-quantification was accomplished based on peak areas in the ion chromatograms. Four illicit additives were identified and semi-quantified in commercial samples. As there was no tedious sample pre-treatment compared with conventional HPLC methods, high-throughput analysis was achieved with DCBI. The results proved that DCBI-MS is a powerful tool for the rapid screening of illicit additives in weight-loss dietary supplements.

  10. Colorimetry and SERS dual-mode detection of telomerase activity: combining rapid screening with high sensitivity.

    PubMed

    Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping

    2014-01-01

    As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an "elongate and capture" procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.

  11. Preventive doping control screening analysis of prohibited substances in human urine using rapid-resolution liquid chromatography/high-resolution time-of-flight mass spectrometry.

    PubMed

    Vonaparti, A; Lyris, E; Angelis, Y S; Panderi, I; Koupparis, M; Tsantili-Kakoulidou, A; Peters, R J B; Nielen, M W F; Georgakopoulos, C

    2010-06-15

    Unification of the screening protocols for a wide range of doping agents has become an important issue for doping control laboratories. This study presents the development and validation of a generic liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) screening method of 241 small molecule analytes from various categories of prohibited substances (stimulants, narcotics, diuretics, beta(2)-agonists, beta-blockers, hormone antagonists and modulators, glucocorticosteroids and anabolic agents). It is based on a single-step liquid-liquid extraction of hydrolyzed urine and the use of a rapid-resolution liquid chromatography/high-resolution time-of-flight mass spectrometric system acquiring continuous full scan data. Electrospray ionization in the positive mode was used. Validation parameters consisted of identification capability, limit of detection, specificity, ion suppression, extraction recovery, repeatability and mass accuracy. Detection criteria were established on the basis of retention time reproducibility and mass accuracy. The suitability of the methodology for doping control was demonstrated with positive urine samples. The preventive role of the method was proved by the case where full scan acquisition with accurate mass measurement allowed the retrospective reprocessing of acquired data from past doping control samples for the detection of a designer drug, the stimulant 4-methyl-2-hexanamine, which resulted in re-reporting a number of stored samples as positives for this particular substance, when, initially, they had been reported as negatives. Copyright (c) 2010 John Wiley & Sons, Ltd.

  12. Rapid and selective screening of melamine in bovine milk using molecularly imprinted matrix solid-phase dispersion coupled with liquid chromatography-ultraviolet detection.

    PubMed

    Yan, Hongyuan; Cheng, Xiaoling; Sun, Ning; Cai, Tianyu; Wu, Ruijun; Han, Kun

    2012-11-01

    A simple, convenient and high selective molecularly imprinted matrix solid-phase dispersion (MI-MSPD) using water-compatible cyromazine-imprinted polymer as adsorbent was proposed for the rapid screening of melamine from bovine milk coupled with liquid chromatography-ultraviolet detection. The molecularly imprinted polymers (MIPs) synthesized by cyromazine as dummy template and reformative methanol-water system as reaction medium showed higher affinity and selectivity to melamine, and so they were applied as the specific dispersant of MSPD to extraction of melamine and simultaneously eliminate the effect of template leakage on quantitative analysis. Under the optimized conditions, good linearity was obtained in a range of 0.24-60.0μgg(-1) with the correlation coefficient of 0.9994. The recoveries of melamine at three spiked levels were ranged from 86.0 to 96.2% with the relative standard deviation (RSD)≤4.0%. This proposed MI-MSPD method combined the advantages of MSPD and MIPs, and could be used as an alternative tool for analyzing the residues of melamine in complex milk samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Rapid assessment of Schistosoma mansoni: the validity, applicability and cost-effectiveness of the Lot Quality Assurance Sampling method in Uganda

    PubMed Central

    Brooker, Simon; Kabatereine, Narcis B.; Myatt, Mark; Stothard, J. Russell; Fenwick, Alan

    2007-01-01

    Summary Rapid and accurate identification of communities at highest risk of morbidity from schistosomiasis is key for sustainable control. Although school questionnaires can effectively and inexpensively identify communities with a high prevalence of Schistosoma haematobium, parasitological screening remains the preferred option for S. mansoni. To help reduce screening costs, we investigated the validity of Lot Quality Assurance Sampling (LQAS) in classifying schools according categories of S. mansoni prevalence in Uganda, and explored its applicability and cost-effectiveness. First, we evaluated several sampling plans using computer simulation and then field tested one sampling plan in 34 schools in Uganda. Finally, cost-effectiveness of different screening and control strategies (including mass treatment without prior screening) was determined, and sensitivity analysis undertaken to assess the effect of infection levels and treatment costs. In identifying schools with prevalence ≥50%, computer simulations showed that LQAS had high levels of sensitivity and specificity (>90%) at sample sizes <20. The method also provides an ability to classify communities into three prevalence categories. Field testing showed that LQAS where 15 children were sampled had excellent diagnostic performance (sensitivity: 100%, specificity: 96.4%, positive predictive value: 85.7% and negative predictive value: 92.3%). Screening using LQAS was more cost-effective than mass treating all schools (US$ 218 vs. US$ 482 / high prevalence school treated). Threshold analysis indicated that parasitological screening and mass treatment would become equivalent for settings where prevalence exceeds 50% in 75% of schools and for treatment costs of US$ 0.19 per schoolchild. We conclude that, in Uganda, LQAS provides a rapid, valid, and cost-effective method for guiding decision makers in allocating finite resources for the control of schistosomiasis. PMID:15960703

  14. Rapid assessment of Schistosoma mansoni: the validity, applicability and cost-effectiveness of the Lot Quality Assurance Sampling method in Uganda.

    PubMed

    Brooker, Simon; Kabatereine, Narcis B; Myatt, Mark; Russell Stothard, J; Fenwick, Alan

    2005-07-01

    Rapid and accurate identification of communities at highest risk of morbidity from schistosomiasis is key for sustainable control. Although school questionnaires can effectively and inexpensively identify communities with a high prevalence of Schistosoma haematobium, parasitological screening remains the preferred option for S. mansoni. To help reduce screening costs, we investigated the validity of Lot Quality Assurance Sampling (LQAS) in classifying schools according to categories of S. mansoni prevalence in Uganda, and explored its applicability and cost-effectiveness. First, we evaluated several sampling plans using computer simulation and then field tested one sampling plan in 34 schools in Uganda. Finally, cost-effectiveness of different screening and control strategies (including mass treatment without prior screening) was determined, and sensitivity analysis undertaken to assess the effect of infection levels and treatment costs. In identifying schools with prevalences > or =50%, computer simulations showed that LQAS had high levels of sensitivity and specificity (>90%) at sample sizes <20. The method also provides an ability to classify communities into three prevalence categories. Field testing showed that LQAS where 15 children were sampled had excellent diagnostic performance (sensitivity: 100%, specificity: 96.4%, positive predictive value: 85.7% and negative predictive value: 92.3%). Screening using LQAS was more cost-effective than mass treating all schools (US$218 vs. US$482/high prevalence school treated). Threshold analysis indicated that parasitological screening and mass treatment would become equivalent for settings where prevalence > or =50% in 75% of schools and for treatment costs of US$0.19 per schoolchild. We conclude that, in Uganda, LQAS provides a rapid, valid and cost-effective method for guiding decision makers in allocating finite resources for the control of schistosomiasis.

  15. Ga-68-DOTATOC: Feasibility of high throughput screening by small animal PET using a clinical high-resolution PET/CT scanner

    NASA Astrophysics Data System (ADS)

    Hofmann, Michael; Weitzel, Thilo; Krause, Thomas

    2006-12-01

    As radio peptide tracers have been developed in recent years for the high sensitive detection of neuroendocrine tumors, still the broad application of other peptides to breast and prostate cancer is missing. A rapid screening of new peptides can, in theory, be based on in vivo screening in animals by PET/CT. To test this hypothesis and to asses the minimum screening time needed per animal, we used the application of Ga-68-DOTATOC PET/CT in rats as test system. The Ga-68-DOTATOC yields in a hot spot imaging with minimal background. To delineate liver and spleen, we performed PET/CT of 10 animals on a SIEMENS Biograph 16 LSO HIGHREZ after intravenous injection of 1.5 MBq Ga-68-DOTATOC per animal. Animals were mounted in an '18 slot' holding device and scanned for a single-bed position. The emission times for the PET scan was varied from 1 to 20 min. The images were assessed first for "PET only" and afterwards in PET/CT fusion mode. The detection of the two organs was good at emission times down to 1 min in PET/CT fusion mode. In the "PET only" scans, the liver was clearly to be identified down to 1 min emission in all animals. But the spleen could only be delineated only by 1 min of emission in the PET/CT-fusion mode. In conclusion the screening of "hot spot" enriching peptides is feasible. "PET only" is in terms of delineation of small organs by far inferior to PET/CT fusion. If animal tumors are above a diameter of 10 mm small, animal PET/CT using clinical high resolution scanners will enable rapid screening. Even the determination of bio-distributions becomes feasible by using list mode tools. The time for the whole survey of 18 animals including anesthesia, preparation and mounting was approximately 20 min. By use of several holding devices mounted simultaneously, a survey time of less than 1 h for 180 animals can be expected.

  16. Integrating GDM management in public health: Pakistan perspective.

    PubMed

    Riaz, Musarrat; Basit, Abdul

    2016-09-01

    Pakistan is a developing country with diverse social, economic and cultural dimensions along with limited resources. Non communicable diseases (NCDS) including diabetes are highly prevalent compromising the already challenged health care system. Gestational diabetes mellitus (GDM) with its associated maternal and foetal complications is increasing with rapidly changing lifestyle pattern. Since Pakistan has limited resources and other health issues compete strongly with gestational diabetes initiatives, the most feasible strategy will be the horizontal integration. This will work with the existing primary health care system integrating NCD control programmes with Maternal and Child health (MCH) programmes. Utilizing the existing health care system is the only implementable cost effective strategy. Antenatal screening and treatment of GDM alone is not sufficient but Post-partum screening (PPS) of women with GDM is an important strategy for prevention of diabetes as the conversion rates of GDM to type 2 diabetes are high. Furthermore, instead of perceiving GDM as a temporary reversible clinical entity, it should be considered as a trans-generational prevention of diabetes that needs to be addressed as a public health issue in order to improve maternal and foetal health.

  17. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  18. Improving the quality of physician communication with rapid-throughput analysis and report cards.

    PubMed

    Farrell, Michael H; Christopher, Stephanie A; La Pean Kirschner, Alison; Roedl, Sara J; O'Tool, Faith O; Ahmad, Nadia Y; Farrell, Philip M

    2014-11-01

    Problems with clinician-patient communication negatively impact newborn screening, genetics, and all of healthcare. Training programs teach communication, but educational methods are not feasible for entire populations of clinicians. To address this healthcare quality gap, we developed a Communication Quality Assurance intervention. Child health providers volunteered for a randomized controlled trial of assessment and a report card. Participants provided telephone counseling to a standardized parent regarding a newborn screening result showing heterozygous status for cystic fibrosis or sickle cell disease. Our rapid-throughput timeline allows individualized feedback within a week. Two encounters were recorded (baseline and after a random sample received the report card) and abstracted for four groups of communication quality indicators. 92 participants finished both counseling encounters within our rapid-throughput time limits. Participants randomized to receive the report card improved communication behaviors more than controls, including request for teach-back (p<0.01), opening behaviors (p=0.01), anticipate/validate emotion (p<0.001) and the ratio of explained to unexplained jargon words (p<0.03). The rapid-throughput report card is effective at improving specific communication behaviors. Communication can be taught, but this project shows how healthcare organizations can assure communication quality everywhere. Further implementation could improve newborn screening, genetics, and healthcare in general. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. A Quality Improvement Initiative to Increase Colorectal Cancer (CRC) Screening: Collaboration between a Primary Care Clinic and Research Team.

    PubMed

    Green, Beverly B; Fuller, Sharon; Anderson, Melissa L; Mahoney, Christine; Mendy, Peter; Powell, Susan L

    2017-01-01

    Multiple randomized controlled trials have demonstrated that mailed fecal testing programs are effective in increasing colorectal cancer screening participation. However, few healthcare organization in the US have Implemented such programs. Stakeholders from one clinic in an integrated healthcare system in Washington State initiated collaboration with researchers with expertise in CRC screening, aiming to increase screening rates at their clinic. Age-eligible individuals who were overdue for CRC screening and had previously completed a fecal test were randomized to receive mailed fecal immunochemical test kits (FIT) at the start of the project (Early) or 6 months later (Late). Outcomes included comparing FIT completion at 6 months by randomization group, and overall CRC screening rates at 12 months. We also assessed implementation facilitators and challenges. Overall 2,421 FIT tests were mailed at a cost of $10,739. At 6 months, FIT completion was significantly higher among the Early compared to the Late group (62% vs.47%, p <0.001). By 12 months, after both groups had received mailings, 71% in each group had completed a FIT. The clinic's overall CRC screening rate was 75.1% at baseline and 78.0% 12 months later. Key constructs associated with successful program implementation included strong stakeholder involvement, use of evidence-based strategies, simplicity, and low cost. Challenges included lack of a plan for maintaining the program. Collaboration between clinic stakeholders and researchers led to a successful project that rapidly increased CRC screening rates. However, institutional normalization of the program would be required to maintain it.

  20. A Quality Improvement Initiative to Increase Colorectal Cancer (CRC) Screening: Collaboration between a Primary Care Clinic and Research Team

    PubMed Central

    Green, Beverly B.; Fuller, Sharon; Anderson, Melissa L.; Mahoney, Christine; Mendy, Peter; Powell, Susan L.

    2017-01-01

    Background Multiple randomized controlled trials have demonstrated that mailed fecal testing programs are effective in increasing colorectal cancer screening participation. However, few healthcare organization in the US have Implemented such programs. Methods Stakeholders from one clinic in an integrated healthcare system in Washington State initiated collaboration with researchers with expertise in CRC screening, aiming to increase screening rates at their clinic. Age-eligible individuals who were overdue for CRC screening and had previously completed a fecal test were randomized to receive mailed fecal immunochemical test kits (FIT) at the start of the project (Early) or 6 months later (Late). Outcomes included comparing FIT completion at 6 months by randomization group, and overall CRC screening rates at 12 months. We also assessed implementation facilitators and challenges. Results Overall 2,421 FIT tests were mailed at a cost of $10,739. At 6 months, FIT completion was significantly higher among the Early compared to the Late group (62% vs.47%, p <0.001). By 12 months, after both groups had received mailings, 71% in each group had completed a FIT. The clinic’s overall CRC screening rate was 75.1% at baseline and 78.0% 12 months later. Key constructs associated with successful program implementation included strong stakeholder involvement, use of evidence-based strategies, simplicity, and low cost. Challenges included lack of a plan for maintaining the program. Discussion Collaboration between clinic stakeholders and researchers led to a successful project that rapidly increased CRC screening rates. However, institutional normalization of the program would be required to maintain it. PMID:29399669

  1. Rapid screening of heavy metals and trace elements in environmental samples using portable X-ray fluorescence spectrometer, A comparative study

    PubMed Central

    McComb, Jacqueline Q.; Rogers, Christian; Han, Fengxiang X.; Tchounwou, Paul B.

    2014-01-01

    With industrialization, great amounts of trace elements and heavy metals have been excavated and released on the surface of the earth and dissipated into the environments. Rapid screening technology for detecting major and trace elements as well as heavy metals in variety of environmental samples is most desired. The objectives of this study were to determine the detection limits, accuracy, repeatability and efficiency of a X-ray fluorescence spectrometer (Niton XRF analyzer) in comparison with the traditional analytical methods, inductively coupled plasma optical emission spectrometer (ICP-OES) and inductively coupled plasma optical emission spectrometer (ICP-MS) in screening of major and trace elements of environmental samples including estuary soils and sediments, contaminated soils, and biological samples. XRF is a fast and non-destructive method in measuring the total concentration of multi--elements simultaneously. Contrary to ICP-OES and ICP-MS, XRF analyzer is characterized by the limited preparation required for solid samples, non-destructive analysis, increased total speed and high throughout, the decreased production of hazardous waste and the low running costs as well as multi-elemental determination and portability in the fields. The current comparative study demonstrates that XRF is a good rapid non-destructive method for contaminated soils, sediments and biological samples containing higher concentrations of major and trace elements. Unfortunately, XRF does not have sensitive detection limits of most major and trace elements as ICP-OES or ICP-MS but it may serve as a rapid screening tool for locating hot spots of uncontaminated field soils and sediments. PMID:25861136

  2. Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Pichini, Simona; Gottardi, Massimo; Marchei, Emilia; Svaizer, Fiorenza; Pellegrini, Manuela; Rotolo, Maria Concetta; Algar, Oscar García; Pacifici, Roberta

    2014-05-01

    Drug testing in hair is a unique analysis in pharmacotoxicology for establishing a past repeated history of consumption or passive exposure to psychotropic substances. A rather lengthy sample treatment is usually required before parent drugs and eventual metabolites are amenable to quali-quantitative analysis. We evaluated a high throughput screening and confirmation analysis of drugs of abuse in hair by immunoassay and a validated ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) after applying a rapid digestion of the keratin matrix with VMA-T reagent before screening assay and M3 reagent before confirmatory analysis. Samples digestion with VMA-T reagent and immunometric screening analysis of hair calibrators, controls and clinical samples for a total of 150 samples was completed in 4 h. No false-positive and -negative results were found for the control material. UPLC-MS/MS analysis confirmed all of the 31 adult hair samples positive to the screening test using internationally established cut-offs, and identified and quantified drugs of abuse in 32 pediatric hair samples, applying lower limits of quantification from 0.01 to 0.1 ng analyte per mg hair. Analytical recovery was between 70.9% and 100.7%. Intra- and inter-assay imprecision and inaccuracy were always lower than 10%. Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and UPLC-MS/MS was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in hair in epidemiological studies.

  3. Optically Based Rapid Screening Method for Proven Optimal Treatment Strategies before Treatment Begins

    DTIC Science & Technology

    2014-08-01

    tumor size, measured by mammography, MRI, or ultrasound. These methods evaluate the regimen that the patient received. Molecular changes induced by...photon counting electronics (SPC-150, Becker and Hickl) and a GaAsP PMT (H7422P-40, Hamamatsu). Photon count rates were maintained above 5x10 5...conditions (33), thus making them an attractive system to evaluate tumor response to drugs. We used OMI to assess the response of primary breast tumor

  4. Information technology-enabled team-based, patient-centered care: The example of depression screening and management in cancer care.

    PubMed

    Randhawa, Gurvaneet S; Ahern, David K; Hesse, Bradford W

    2017-03-01

    The existing healthcare delivery systems across the world need to be redesigned to ensure high-quality care is delivered to all patients. This redesign needs to ensure care is knowledge-based, patient-centered and systems-minded. The rapid advances in the capabilities of information and communication technology and its recent rapid adoption in healthcare delivery have ensured this technology will play a vital role in the redesign of the healthcare delivery system. This commentary highlights promising new developments in health information technology (IT) that can support patient engagement and self-management as well as team-based, patient-centered care. Collaborative care is an effective approach to screen and treat depression in cancer patients and it is a good example of the benefits of team-based and patient-centered care. However, this approach was developed prior to the widespread adoption and use of health IT. We provide examples to illustrate how health IT can improve prevention and treatment of depression in cancer patients. We found several knowledge gaps that limit our ability to realize the full potential of health IT in the context of cancer and comorbid depression care. These gaps need to be filled to improve patient engagement; enhance the reach and effectiveness of collaborative care and web-based programs to prevent and treat depression in cancer patients. We also identify knowledge gaps in health IT design and implementation. Filling these gaps will help shape policies that enable clinical teams to deliver high-quality cancer care globally.

  5. High throughput screening of CO2-tolerating microalgae using GasPak bags

    PubMed Central

    2013-01-01

    Background Microalgae are diverse in terms of their speciation and function. More than 35,000 algal strains have been described, and thousands of algal cultures are maintained in different culture collection centers. The ability of CO2 uptake by microalgae varies dramatically among algal species. It becomes challenging to select suitable algal candidates that can proliferate under high CO2 concentration from a large collection of algal cultures. Results Here, we described a high throughput screening method to rapidly identify high CO2 affinity microalgae. The system integrates a CO2 mixer, GasPak bags and microplates. Microalgae on the microplates will be cultivated in GasPak bags charged with different CO2 concentrations. Using this method, we identified 17 algal strains whose growth rates were not influenced when the concentration of CO2 was increased from 2 to 20% (v/v). Most CO2 tolerant strains identified in this study were closely related to the species Scenedesmus and Chlorococcum. One of Scenedesmus strains (E7A) has been successfully tested in in the scale up photo bioreactors (500 L) bubbled with flue gas which contains 10-12% CO2. Conclusion Our high throughput CO2 testing system provides a rapid and reliable way for identifying microalgal candidate strains that can grow under high CO2 condition from a large pool of culture collection species. This high throughput system can also be modified for selecting algal strains that can tolerate other gases, such as NOx, SOx, or flue gas. PMID:24341988

  6. Biomarkers of Acute Respiratory Allergen Exposure: Screening For Sensitization Potential

    EPA Science Inventory

    Rationale: An in vitro assay to identify respiratory sensitizers will provide a rapid screen and reduce animal use. The study goal was to identify biomarkers that differentiate allergen versus non-allergen responses following an acute exposure. Methods: Female BALB/c mice rec...

  7. Neuronal models for evaluation of proliferation in vitro using high content screening

    EPA Science Inventory

    In vitro test methods can provide a rapid approach for the screening of large numbers of chemicals for their potential to produce toxicity (hazard identification). In order to identify potential developmental neurotoxicants, a battery of in vitro tests for neurodevelopmental proc...

  8. Gene Expression Changes in Developing Zebrafish as Potential Markers for Rapid Developmental Neurotoxicity Screening

    EPA Science Inventory

    Sparse information exists on many chemicals to guide developmental neurotoxicity (DNT) risk assessments. As DNT testing using rodents is laborious and expensive, alternative species such as zebrafish are being adapted for toxicity screening. Assessing the DNT potential of chem...

  9. RAPID SCREENING OF ENVIRONMENTAL CHEMICALS FOR ESTROGEN RECEPTOR BINDING CAPACITY

    EPA Science Inventory

    Over the last few years, an increased awareness of endocrine disrupting chemicals (EDCs) and their potential to affect wildlife and humans has produced a demand for practical screening methods to identify endocrine activity in a wide range of environmental and industrial chemical...

  10. The Feasibility of Standardised Geriatric Assessment Tools and Physical Exercises in Frail Older Adults.

    PubMed

    Jadczak, A D; Mahajan, N; Visvanathan, R

    2017-01-01

    Geriatric assessment tools are applicable to the general geriatric population; however, their feasibility in frail older adults is yet to be determined. The study aimed to determine the feasibility of standardised geriatric assessment tools and physical exercises in hospitalised frail older adults. Various assessment tools including the FRAIL Screen, the Charlson Comorbidity Index, the SF-36, the Trail Making Test (TMT), the Rapid Cognitive Screen, the Self Mini Nutritional Assessment (MNA-SF) and the Lawton iADL as well as standard physical exercises were assessed using observational protocols. The FRAIL Screen, MNA-SF, Rapid Cognitive Screen, Lawton iADL and the physical exercises were deemed to be feasible with only minor comprehension, execution and safety issues. The TMT was not considered to be feasible and the SF-36 should be replaced by its shorter form, the SF-12. In order to ensure the validity of these findings a study with a larger sample size should be undertaken.

  11. Rapid screening and species identification of E. coli, Listeria, and Salmonella by SERS technique

    NASA Astrophysics Data System (ADS)

    Liu, Yongliang; Chao, Kuanglin; Kim, Moon S.; Nou, Xiangwu

    2008-04-01

    Techniques for routine and rapid screening of the presence of foodborne bacteria are needed, and this study reports the feasibility of citrate-reduced silver colloidal SERS for identifying E. coli, Listeria, and Salmonella. Relative standard deviation (RSD) of SERS spectra from silver colloidal suspensions and ratios of P-O SERS peaks from small molecule (K3PO4) were used to assess the reproducibility, stability, and binding effectiveness of citrate-reduced silver colloids over batch and storage process. The results suggested the reproducibility of silver colloids over batch process and also stability and consistent binding effectiveness over 60-day storage period. Notably, although silver colloidal nanoparticles were stable for at least 90 days, their binding effectiveness began to decrease slightly after 60-day storage, with a binding reduction of about 12% at 90th day. Colloidal silver SERS, as demonstrated here, could be an important alternative technique in the rapid and simultaneous screening of the presence of three most outbreak bacteria due to the exclusive biomarkers, label-free and easy sampling attribute.

  12. Multiple search methods for similarity-based virtual screening: analysis of search overlap and precision

    PubMed Central

    2011-01-01

    Background Data fusion methods are widely used in virtual screening, and make the implicit assumption that the more often a molecule is retrieved in multiple similarity searches, the more likely it is to be active. This paper tests the correctness of this assumption. Results Sets of 25 searches using either the same reference structure and 25 different similarity measures (similarity fusion) or 25 different reference structures and the same similarity measure (group fusion) show that large numbers of unique molecules are retrieved by just a single search, but that the numbers of unique molecules decrease very rapidly as more searches are considered. This rapid decrease is accompanied by a rapid increase in the fraction of those retrieved molecules that are active. There is an approximately log-log relationship between the numbers of different molecules retrieved and the number of searches carried out, and a rationale for this power-law behaviour is provided. Conclusions Using multiple searches provides a simple way of increasing the precision of a similarity search, and thus provides a justification for the use of data fusion methods in virtual screening. PMID:21824430

  13. Fourier-transform infrared spectroscopy for rapid screening and live-cell monitoring: application to nanotoxicology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sundaram, S. K.; Sacksteder, Colette A.; Weber, T. J.

    2013-01-01

    A significant challenge to realize the full potential of nanotechnology for therapeutic and diagnostic applications is to understand and evaluate how live-cells interact with an external stimulus, e.g., a nanosized particle (NSP), and the toxicity and broad risk associated with these stimuli. NSPs are increasingly used in medicine with largely undetermined hazards in complex cell dynamics and environments. It is difficult to capture the complexity and dynamics of these interactions by following an omics-based approach exclusively, which are expensive and time-consuming. Additionally, this approach needs destructive sampling methods. Live-cell attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectrometry is well suited tomore » provide noninvasive approach to provide rapid screening of cellular responses to potentially toxic NSPs or any stimuli. Herein we review the technical basis of the approach, the instrument configuration and interface with the biological media, and various effects that impact the data, data analysis, and toxicity. Our preliminary results on live-cell monitoring show promise for rapid screening the NSPs.« less

  14. Differentially pumped spray deposition as a rapid screening tool for organic and perovskite solar cells.

    PubMed

    Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H; Watkins, Scott E; Kim, Dong-Yu; Vak, Doojin

    2016-02-08

    We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%.

  15. Virtual screening of inorganic materials synthesis parameters with deep learning

    NASA Astrophysics Data System (ADS)

    Kim, Edward; Huang, Kevin; Jegelka, Stefanie; Olivetti, Elsa

    2017-12-01

    Virtual materials screening approaches have proliferated in the past decade, driven by rapid advances in first-principles computational techniques, and machine-learning algorithms. By comparison, computationally driven materials synthesis screening is still in its infancy, and is mired by the challenges of data sparsity and data scarcity: Synthesis routes exist in a sparse, high-dimensional parameter space that is difficult to optimize over directly, and, for some materials of interest, only scarce volumes of literature-reported syntheses are available. In this article, we present a framework for suggesting quantitative synthesis parameters and potential driving factors for synthesis outcomes. We use a variational autoencoder to compress sparse synthesis representations into a lower dimensional space, which is found to improve the performance of machine-learning tasks. To realize this screening framework even in cases where there are few literature data, we devise a novel data augmentation methodology that incorporates literature synthesis data from related materials systems. We apply this variational autoencoder framework to generate potential SrTiO3 synthesis parameter sets, propose driving factors for brookite TiO2 formation, and identify correlations between alkali-ion intercalation and MnO2 polymorph selection.

  16. Differentially pumped spray deposition as a rapid screening tool for organic and perovskite solar cells

    PubMed Central

    Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H.; Watkins, Scott E.; Kim, Dong-Yu; Vak, Doojin

    2016-01-01

    We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%. PMID:26853266

  17. From Omics to Drug Metabolism and High Content Screen of Natural Product in Zebrafish: A New Model for Discovery of Neuroactive Compound

    PubMed Central

    Hung, Ming Wai; Zhang, Zai Jun; Li, Shang; Lei, Benson; Yuan, Shuai; Cui, Guo Zhen; Man Hoi, Pui; Chan, Kelvin; Lee, Simon Ming Yuen

    2012-01-01

    The zebrafish (Danio rerio) has recently become a common model in the fields of genetics, environmental science, toxicology, and especially drug screening. Zebrafish has emerged as a biomedically relevant model for in vivo high content drug screening and the simultaneous determination of multiple efficacy parameters, including behaviour, selectivity, and toxicity in the content of the whole organism. A zebrafish behavioural assay has been demonstrated as a novel, rapid, and high-throughput approach to the discovery of neuroactive, psychoactive, and memory-modulating compounds. Recent studies found a functional similarity of drug metabolism systems in zebrafish and mammals, providing a clue with why some compounds are active in zebrafish in vivo but not in vitro, as well as providing grounds for the rationales supporting the use of a zebrafish screen to identify prodrugs. Here, we discuss the advantages of the zebrafish model for evaluating drug metabolism and the mode of pharmacological action with the emerging omics approaches. Why this model is suitable for identifying lead compounds from natural products for therapy of disorders with multifactorial etiopathogenesis and imbalance of angiogenesis, such as Parkinson's disease, epilepsy, cardiotoxicity, cerebral hemorrhage, dyslipidemia, and hyperlipidemia, is addressed. PMID:22919414

  18. Rapid screening, identification, and purification of neuraminidase inhibitors from Lithospermum erythrorhizon Sieb.et Zucc. by ultrafiltration with HPLC-ESI-TOF-MS combined with semipreparative HPLC.

    PubMed

    Zhang, Minmin; Zhao, Hengqiang; Zhao, Zhiguo; Yan, Huijiao; Lv, Ruimin; Cui, Li; Yuan, Jinpeng; Wang, Daijie; Geng, Yanling; Liu, Daicheng; Wang, Xiao

    2016-06-01

    We put forward an efficient strategy based on bioassay guidance for the rapid screening, identification, and purification of the neuraminidase inhibitors from traditional Chinese medicines, and apply to the discovery of anti-influenza components from Lithospermiun erythrorhizon Sieb.et Zucc. Ultrafiltration with high-performance liquid chromatography and electrospray ionization time-of-flight mass spectrometry was employed for the rapid screening and preliminarily identification of anti-influenza components from Zicao. Semipreparative high-performance liquid chromatography was used for the rapid separation and purification of the target compounds. NMR spectroscopy, mass spectrometry, and UV spectroscopy were used for further structural identification, and the activity of the compounds was verified by in vitro assay. Five compounds were found to have neuraminidase inhibitory activity by this method. Subsequently, the five compounds were separated by semipreparative high-performance liquid chromatography with the purity over 98% for all of them by high-performance liquid chromatography test. Combined with the NMR spectroscopy, mass spectrometry, and UV spectroscopy data, they were identified as alkannin, acetylalkannin, isobutyrylalkannin, β,β-dimethylacryloylalkannin and isovalerylalkannin. The in vitro assay showed that all five compounds had good neuraminidase inhibitory activities. These results suggested that the method is highly efficient, and it can provide platform and methodology supports for the rapid discovery of anti-influenza active ingredients from complex Chinese herbal medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Design and implementation of a controlled clinical trial to evaluate the effectiveness and efficiency of routine opt-out rapid human immunodeficiency virus screening in the emergency department.

    PubMed

    Haukoos, Jason S; Hopkins, Emily; Byyny, Richard L; Conroy, Amy A; Silverman, Morgan; Eisert, Sheri; Thrun, Mark; Wilson, Michael; Boyett, Brian; Heffelfinger, James D

    2009-08-01

    In 2006, the Centers for Disease Control and Prevention (CDC) released revised recommendations for performing human immunodeficiency virus (HIV) testing in health care settings, including implementing routine rapid HIV screening, the use of an integrated opt-out consent, and limited prevention counseling. Emergency departments (EDs) have been a primary focus of these efforts. These revised CDC recommendations were primarily based on feasibility studies and have not been evaluated through the application of rigorous research methods. This article describes the design and implementation of a large prospective controlled clinical trial to evaluate the CDC's recommendations in an ED setting. From April 15, 2007, through April 15, 2009, a prospective quasi-experimental equivalent time-samples clinical trial was performed to compare the clinical effectiveness and efficiency of routine (nontargeted) opt-out rapid HIV screening (intervention) to physician-directed diagnostic rapid HIV testing (control) in a high-volume urban ED. In addition, three nested observational studies were performed to evaluate the cost-effectiveness and patient and staff acceptance of the two rapid HIV testing methods. This article describes the rationale, methodologies, and study design features of this program evaluation clinical trial. It also provides details regarding the integration of the principal clinical trial and its nested observational studies. Such ED-based trials are rare, but serve to provide valid comparisons between testing approaches. Investigators should consider similar methodology when performing future ED-based health services research.

  20. [Elaboration of Pseudo-natural Products Using Artificial In Vitro Biosynthesis Systems].

    PubMed

    Goto, Yuki

    2018-01-01

     Peptidic natural products often consist of not only proteinogenic building blocks but also unique non-proteinogenic structures such as macrocyclic scaffolds and N-methylated backbones. Since such non-proteinogenic structures are important structural motifs that contribute to diverse bioactivity, we have proposed that peptides with non-proteinogenic structures should be attractive candidates as artificial bioactive peptides mimicking natural products, or so-called pseudo-natural products. We previously devised an engineered translation system for pseudo-natural peptides, referred to as the flexible in vitro translation (FIT) system. This system enabled "one-pot" synthesis of highly diverse pseudo-natural peptide libraries, which can be rapidly screened by mRNA display technology for the discovery of pseudo-natural peptides with diverse bioactivities.

  1. [Possibility and necessity of constructing new nanoformula systems of traditional Chinese medicine].

    PubMed

    Ling, Chang-quan; Su, Yong-hua

    2010-02-01

    The past decade has witnessed the remarkable progress on nanotechnology and nanoherb. With the globally rapid development of nanotechnology, we are considering to construct new nanoformula systems of traditional Chinese medicine (TCM) by using porous materials, multilayered core-shell particles or nanoparticles containing various multifunctional parts. With the compatibility of sovereign, minister, assistant and courier in a formula, new nanoformula systems of TCM will have various advantages, such as containing multiple active species, controlled release, targeting function, and labeling and tracing capabilities. Using the latest breakthroughs of nanotechnology for the modern research of TCM will greatly help enhance the ability to investigate the principles of TCM, and to design, screen and utilize new nanoformula systems of TCM.

  2. Novel heparan sulfate assay by using automated high-throughput mass spectrometry: application to monitoring and screening for mucopolysaccharidoses

    PubMed Central

    Shimada, Tsutomu; Kelly, Joan; LaMarr, William A; van Vlies, Naomi; Yasuda, Eriko; Mason, Robert W.; Mackenzie, William; Kubaski, Francyne; Giugliani, Roberto; Chinen, Yasutsugu; Yamaguchi, Seiji; Suzuki, Yasuyuki; Orii, Kenji E.; Fukao, Toshiyuki; Orii, Tadao; Tomatsu, Shunji

    2014-01-01

    Mucopolysaccharidoses (MPS) are caused by deficiency of one of a group of specific lysosomal enzymes, resulting in excessive accumulation of glycosaminoglycans (GAGs). We previously developed GAG assay methods using liquid chromatography tandem mass spectrometry (LC-MS/MS); however, it takes 4–5 min per sample for analysis. For the large numbers of samples in a screening program, a more rapid process is desirable. The automated high-throughput mass spectrometry (HT-MS/MS) system (RapidFire) integrates a solid phase extraction robot to concentrate and desalt samples prior to direction into the MS/MS without chromatographic separation; thereby allowing each sample to be processed within ten seconds (enabling screening of more than one million samples per year). The aim of this study was to develop a higher throughput system to assay heparan sulfate (HS) using HT-MS/MS, and to compare its reproducibility, sensitivity and specificity with conventional LC-MS/MS. HS levels were measured in blood (plasma and serum) from control subjects and patients with MPS II, III, or IV and in dried blood spots (DBS) from newborn controls and patients with MPS I, II, or III. Results obtained from HT-MS/MS showed 1) that there was a strong correlation of levels of disaccharides derived from HS in blood, between those calculated using conventional LC-MS/MS and HT-MS/MS, 2) that levels of HS in blood were significantly elevated in patients with MPS II and III, but not in MPS IVA, 3) that the level of HS in patients with a severe form of MPS II was higher than that in an attenuated form, 4) that reduction of blood HS level was observed in MPS II patients treated with enzyme replacement therapy or hematopoietic stem cell transplantation, and 5) that levels of HS in newborn DBS were elevated in patients with MPS I, II or III, compared to control newborns. In conclusion, HT-MS/MS provides much higher throughput than LC-MS/MS-based methods with similar sensitivity and specificity in an HS assay, indicating that HT-MS/MS may be feasible for diagnosis, monitoring, and newborn screening of MPS. PMID:25092413

  3. Rapid review of cognitive screening instruments in MCI: proposal for a process-based approach modification of overlapping tasks in select widely used instruments.

    PubMed

    Díaz-Orueta, Unai; Blanco-Campal, Alberto; Burke, Teresa

    2018-05-01

    ABSTRACTBackground:A detailed neuropsychological assessment plays an important role in the diagnostic process of Mild Cognitive Impairment (MCI). However, available brief cognitive screening tests for this clinical population are administered and interpreted based mainly, or exclusively, on total achievement scores. This score-based approach can lead to erroneous clinical interpretations unless we also pay attention to the test taking behavior or to the type of errors committed during test performance. The goal of the current study is to perform a rapid review of the literature regarding cognitive screening tools for dementia in primary and secondary care; this will include revisiting previously published systematic reviews on screening tools for dementia, extensive database search, and analysis of individual references cited in selected studies. A subset of representative screening tools for dementia was identified that covers as many cognitive functions as possible. How these screening tools overlap with each other (in terms of the cognitive domains being measured and the method used to assess them) was examined and a series of process-based approach (PBA) modifications for these overlapping features was proposed, so that the changes recommended in relation to one particular cognitive task could be extrapolated to other screening tools. It is expected that future versions of cognitive screening tests, modified using a PBA, will highlight the benefits of attending to qualitative features of test performance when trying to identify subtle features suggestive of MCI and/or dementia.

  4. Prospective quality initiative to maximize dysphagia screening reduces hospital-acquired pneumonia prevalence in patients with stroke.

    PubMed

    Titsworth, W Lee; Abram, Justine; Fullerton, Amy; Hester, Jeannette; Guin, Peggy; Waters, Michael F; Mocco, J

    2013-11-01

    Dysphagia can lead to pneumonia and subsequent death after acute stroke. However, no prospective study has demonstrated reduced pneumonia prevalence after implementation of a dysphagia screen. We performed a single-center prospective interrupted time series trial of a quality initiative to improve dysphagia screening. Subjects included all patients with ischemic or hemorrhagic stroke admitted to our institution over 42 months with a 31-month (n=1686) preintervention and an 11-month (n=648) postintervention period. The intervention consisted of a dysphagia protocol with a nurse-administered bedside dysphagia screen and a reflexive rapid clinical swallow evaluation by a speech pathologist. The dysphagia initiative increased the percentage of patients with stroke screened from 39.3% to 74.2% (P<0.001). Furthermore, this initiative coincided with a drop in hospital-acquired pneumonia from 6.5% to 2.8% among patients with stroke (P<0.001). Patients admitted postinitiative had 57% lower odds of pneumonia, after controlling for multiple confounds (odds ratio=0.43; confidence interval, 0.255-0.711; P=0.0011). The best predictors of pneumonia were stroke type (P<0.0001), oral intake status (P<0.0001), dysphagia screening status (P=0.0037), and hospitalization before the beginning of the quality improvement initiative (P=0.0449). A quality improvement initiative using a nurse-administered bedside screen with rapid bedside swallow evaluation by a speech pathologist improves screening compliance and correlates with decreased prevalence of pneumonia among patients with stroke.

  5. Rapid prediction of single green coffee bean moisture and lipid content by hyperspectral imaging.

    PubMed

    Caporaso, Nicola; Whitworth, Martin B; Grebby, Stephen; Fisk, Ian D

    2018-06-01

    Hyperspectral imaging (1000-2500 nm) was used for rapid prediction of moisture and total lipid content in intact green coffee beans on a single bean basis. Arabica and Robusta samples from several growing locations were scanned using a "push-broom" system. Hypercubes were segmented to select single beans, and average spectra were measured for each bean. Partial Least Squares regression was used to build quantitative prediction models on single beans (n = 320-350). The models exhibited good performance and acceptable prediction errors of ∼0.28% for moisture and ∼0.89% for lipids. This study represents the first time that HSI-based quantitative prediction models have been developed for coffee, and specifically green coffee beans. In addition, this is the first attempt to build such models using single intact coffee beans. The composition variability between beans was studied, and fat and moisture distribution were visualized within individual coffee beans. This rapid, non-destructive approach could have important applications for research laboratories, breeding programmes, and for rapid screening for industry.

  6. Rapid identification of herbal compounds derived metabolites using zebrafish larvae as the biotransformation system.

    PubMed

    Wang, Chen; Yin, Ying-Hao; Wei, Ying-Jie; Shi, Zi-Qi; Liu, Jian-Qun; Liu, Li-Fang; Xin, Gui-Zhong

    2017-09-15

    Metabolites derived from herbal compounds are becoming promising sources for discovering new drugs. However, the rapid identification of metabolites from biological matrixes is limited by massive endogenous interference and low abundance of metabolites. Thus, by using zebrafish larvae as the biotransformation system, we herein proposed and validated an integrated strategy for rapid identification of metabolites derived from herbal compounds. Two pivotal steps involved in this strategy are to differentiate metabolites from herbal compounds and match metabolites with their parent compounds. The differentiation step was achieved by cross orthogonal partial least-squares discriminant analysis. Automatic matching analysis was performed on R Project based on a self-developed program, of which the number of matched ionic clusters and its corresponding percentage between metabolite and parent compound were taken into account to assess their similarity. Using this strategy, 46 metabolites screened from incubation water samples of zebrafish treated with total Epimedium flavonoids (EFs) could be matched with their corresponding parent compounds, 37 of them were identified and validated by the known metabolic pathways and fragmentation patterns. Finally, 75% of the identified EFs metabolites were successfully detected in urine samples of rats treated with EFs. These experimental results indicate that the proposed strategy using zebrafish larvae as the biotransformation system will facilitate the rapid identification of metabolites derived from herbal compounds, which shows promising perspectives in providing additional resources for pharmaceutical developments from natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Fluorescent and Lanthanide Labeling for Ligand Screens, Assays, and Imaging

    PubMed Central

    Josan, Jatinder S.; De Silva, Channa R.; Yoo, Byunghee; Lynch, Ronald M.; Pagel, Mark D.; Vagner, Josef; Hruby, Victor J.

    2012-01-01

    The use of fluorescent (or luminescent) and metal contrast agents in high-throughput screens, in vitro assays, and molecular imaging procedures has rapidly expanded in recent years. Here we describe the development and utility of high-affinity ligands for cancer theranostics and other in vitro screening studies. In this context, we also illustrate the syntheses and use of heteromultivalent ligands as targeted imaging agents. PMID:21318902

  8. An in vitro AChE inhibition assay combined with UF-HPLC-ESI-Q-TOF/MS approach for screening and characterizing of AChE inhibitors from roots of Coptis chinensis Franch.

    PubMed

    Zhao, Hengqiang; Zhou, Siduo; Zhang, Minmin; Feng, Jinhong; Wang, Shanshan; Wang, Daijie; Geng, Yanling; Wang, Xiao

    2016-02-20

    In this study, an in vitro acetylcholinesterase (AChE) inhibition assay based on microplate reader combined with ultrafiltration high performance liquid chromatography-electrospray quadrupole time of flight mass (UF-HPLC-ESI-Q-TOF/MS) was developed for the rapid screening and identification of acetylcholinesterase inhibitors (AChEI) from roots of Coptis chinensis Franch. Incubation conditions such as enzyme concentration, incubation time, incubation temperature and co-solvent was optimized so as to get better screening results. Five alkaloids including columbamine, jatrorrhizine, coptisine, palmatine and berberine were found with AChE inhibition activity in the 80% ethanol extract of C. chinensis Franch. The screened compounds were identified by HPLC-DAD-ESI-Q-TOF/MS compared with the reference stands and literatures. The screened results were verified by in vitro AChE inhibition assays, palmatine showed the best AChE inhibitory activities with IC50 values of 36.6μM among the five compounds. Results of the present study indicated that the combinative method using in vitro AChE inhibition assay and UF-HPLC-ESI-Q-TOF/MS could be widely applied for rapid screening and identification of AChEI from complex TCM extract. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Analysis of suspicious powders following the post 9/11 anthrax scare.

    PubMed

    Wills, Brandon; Leikin, Jerrold; Rhee, James; Saeedi, Bijan

    2008-06-01

    Following the 9/11 terrorist attacks, SET Environmental, Inc., a Chicago-based environmental and hazardous materials management company received a large number of suspicious powders for analysis. Samples of powders were submitted to SET for anthrax screening and/or unknown identification (UI). Anthrax screening was performed on-site using a ruggedized analytical pathogen identification device (R.A.P.I.D.) (Idaho Technologies, Salt Lake City, UT). UI was performed at SET headquarters (Wheeling, IL) utilizing a combination of wet chemistry techniques, infrared spectroscopy, and gas chromatography/mass spectroscopy. Turnaround time was approximately 2-3 hours for either anthrax or UI. Between October 10, 2001 and October 11, 2002, 161 samples were analyzed. Of these, 57 were for anthrax screening only, 78 were for anthrax and UI, and 26 were for UI only. Sources of suspicious powders included industries (66%), U.S. Postal Service (19%), law enforcement (9%), and municipalities (7%). There were 0/135 anthrax screens that were positive. There were no positive anthrax screens performed by SET in the Chicago area following the post-9/11 anthrax scare. The only potential biological or chemical warfare agent identified (cyanide) was provided by law enforcement. Rapid anthrax screening and identification of unknown substances at the scene are useful to prevent costly interruption of services and potential referral for medical evaluation.

  10. An Automated Detection System for Microaneurysms That Is Effective across Different Racial Groups.

    PubMed

    Saleh, George Michael; Wawrzynski, James; Caputo, Silvestro; Peto, Tunde; Al Turk, Lutfiah Ismail; Wang, Su; Hu, Yin; Da Cruz, Lyndon; Smith, Phil; Tang, Hongying Lilian

    2016-01-01

    Patients without diabetic retinopathy (DR) represent a large proportion of the caseload seen by the DR screening service so reliable recognition of the absence of DR in digital fundus images (DFIs) is a prime focus of automated DR screening research. We investigate the use of a novel automated DR detection algorithm to assess retinal DFIs for absence of DR. A retrospective, masked, and controlled image-based study was undertaken. 17,850 DFIs of patients from six different countries were assessed for DR by the automated system and by human graders. The system's performance was compared across DFIs from the different countries/racial groups. The sensitivities for detection of DR by the automated system were Kenya 92.8%, Botswana 90.1%, Norway 93.5%, Mongolia 91.3%, China 91.9%, and UK 90.1%. The specificities were Kenya 82.7%, Botswana 83.2%, Norway 81.3%, Mongolia 82.5%, China 83.0%, and UK 79%. There was little variability in the calculated sensitivities and specificities across the six different countries involved in the study. These data suggest the possible scalability of an automated DR detection platform that enables rapid identification of patients without DR across a wide range of races.

  11. Phosphate Detection through a Cost-Effective Carbon Black Nanoparticle-Modified Screen-Printed Electrode Embedded in a Continuous Flow System.

    PubMed

    Talarico, Daria; Cinti, Stefano; Arduini, Fabiana; Amine, Aziz; Moscone, Danila; Palleschi, Giuseppe

    2015-07-07

    An automatable flow system for the continuous and long-term monitoring of the phosphate level has been developed using an amperometric detection method based on the use of a miniaturized sensor. This method is based on the monitoring of an electroactive complex obtained by the reaction between phosphate and molybdate that is consequently reduced at the electrode surface. The use of a screen-printed electrode modified with carbon black nanoparticles (CBNPs) leads to the quantification of the complex at low potential, because CBNPs are capable of electrocatalitically enhancing the phosphomolybdate complex reduction at +125 mV versus Ag/AgCl without fouling problems. The developed system also incorporates reagents and waste storage and is connected to a portable potentiostat for rapid detection and quantification of phosphate. Main analytical parameters, such as working potential, reagent concentration, type of cell, and flow rate, were evaluated and optimized. This system was characterized by a low detection limit (6 μM). Interference studies were carried out. Good recovery percentages comprised between 89 and 131.5% were achieved in different water sources, highlighting its suitability for field measurements.

  12. Developmental neurotoxicity testing in vitro: Models for assessing chemical effects on neurite outgrowth

    EPA Science Inventory

    In vitro models may be useful for the rapid toxicological screening of large numbers of chemicals for their potential to produce toxicity. Such screening could facilitate prioritization of resources needed for in vivo toxicity testing towards those chemicals most likely to resul...

  13. Label-free screening of foodborne Salmonella using surface plasmon resonance imaging

    USDA-ARS?s Scientific Manuscript database

    Since 15 pathogens cause approximately 95% of the foodborne infections, it is desirable to develop rapid and simultaneous screening methods for these major pathogens. In this study, we developed an immunoassay for Salmonella based on surface plasmon resonance imaging (SPRi). The sensor surface modif...

  14. Parents' perspectives of change in child physical activity & screen-viewing between Y1 (5-6) & Y4 (8-9) of primary school: implications for behaviour change.

    PubMed

    Jago, Russell; Solomon-Moore, Emma; Toumpakari, Zoi; Lawlor, Deborah A; Thompson, Janice L; Sebire, Simon J

    2018-04-19

    The aim of this study was to explore parents' responses to changes in children's physical activity and screen-time between Year 1 (5-6 years) and Year 4 (8-9 years of age) of primary school. A secondary aim was to identify how parents adapt their parenting to rapidly changing screen-based technology. Data were from the longitudinal B-Proact1v Study. Semi-structured telephone interviews were conducted between July and October 2016 with a sub-sample of 51 parents who participated in the study at Year 4. The sample was drawn from 1223 families who took part in the B-Proact1v in which the children wore an accelerometer for 5 days and mean minutes of moderate to vigorous intensity physical activity (MVPA) and sedentary minutes per day were derived. This sample was stratified according to the child's MVPA and sedentary (SED) minutes per day, and by child gender. Data were thematically analysed. Analysis yielded five main themes: 1) Parents reported how children's interests change with free play decreasing and structured activity increasing. 2) Parents highlighted how their children's independence and ability to make choices in relation to physical activity and screen-viewing increase, and that parental influence decreased, as the child gets older. 3) Parents reported that the transition from Year 1 to Year 4 appeared to be a time of substantial change in the screen-based devices that children used and the content that they viewed. 4) Parents reported that managing screen-viewing was harder compared to three years ago and a third of parents expressed concerns about the difficulty of managing screen-viewing in the future. 5) Parents reported using general principles for managing children's screen-viewing including engaging the children with rule setting and encouraging self-regulation. Parents reported that children's physical activity and sedentary screen behaviours change between Year 1 and Year 4 with children obtaining increased licence to influence the type, location and frequency with which they are active or sedentary. These changes and rapid advances in screen-viewing technology are a challenge for parents to negotiate and highlight a need to develop innovative and flexible strategies to help parents adapt to a rapidly changing environment.

  15. Operational research leading to rapid national policy change: tuberculosis-diabetes collaboration in India.

    PubMed

    Kumar, A M V; Satyanarayana, S; Wilson, N C; Chadha, S S; Gupta, D; Nair, S; Zachariah, R; Kapur, A; Harries, A D

    2014-06-21

    In 2011, bi-directional screening for tuberculosis (TB) and diabetes mellitus (DM) was recommended by the World Health Organization (WHO), although how best to implement the activity was not clear. In India, with early engagement of national programme managers and all important stakeholders, a countrywide, multicentre operational research (OR) project was designed in October 2011 and completed in 2012. The results led to a rapid national policy decision to routinely screen all TB patients for DM in September 2012. The process, experience and enablers of implementing this unique and successful collaborative model of operational research are presented.

  16. Enhancing HIV Testing and Treatment among Men Who Have Sex with Men in China: A Pilot Model with Two-Rapid Tests, Single Blood Draw Session, and Intensified Case Management in Six Cities in 2013.

    PubMed

    Zhang, Dapeng; Lu, Hongyan; Zhuang, Minghua; Wu, Guohui; Yan, Hongjing; Xu, Jun; Wei, Xiaoli; Li, Chengmei; Meng, Sining; Fu, Xiaojing; Qi, Jinlei; Wang, Peng; Luo, Mei; Dai, Min; Yip, Ray; Sun, Jiangping; Wu, Zunyou

    2016-01-01

    To explore models to improve HIV testing, linkage to care and treatment among men who have sex with men (MSM) in cooperation with community-based organizations (CBOs) in China. We introduced a new model for HIV testing services targeting MSM in six cities in 2013.These models introduced provision of rapid HIV testing by CBO staff and streamlined processes for HIV screening, confirmation of initial reactive screening results, and linkage to care among diagnosed people. We monitored attrition along each step of the continuum of care from screening to treatment and compared program performance between 2012 and 2013. According to the providers of two rapid tests (HIV screening), four different services delivery models were examined in 2013: Model A = first screen at CDC, second at CDC (Model A = CDC+CDC), Model B = first and second screens at CBOs (Model B = CBO+CBO), Model C = first screen at CBO, second at Hospital (Model C = CBO+Hosp), and Model D = first screen at CBO, second at CDC (Model D = CBO+CDC). Logistic regressions were performed to assess advantages of different screening models of case finding and case management. Compared to 2012, the number of HIV screening tests performed for MSM increased 35.8% in 2013 (72,577 in 2013 vs. 53,455 in 2012). We observed a 5.6% increase in proportion of cases screened reactive receiving HIV confirmatory tests (93.9% in 2013 vs. 89.2% in 2012, χ2 = 48.52, p<0.001) and 65% reduction in loss to CD4 cell count tests (15% in 2013 vs. 43% in 2012, χ2 = 628.85, p<0.001). Regarding linkage to care and treatment, the 2013 pilot showed that the Model D had the highest rate of loss between screening reactive and confirmatory test among the four models, with 18.1% fewer receiving a second screening test and a further 5.9% loss among those receiving HIV confirmatory tests. The Model B and the Model C showed lower losses (0.8% and 1.3%) for newly diagnosed HIV positives receiving CD4 cell count tests, and higher rates of HIV positives referred to designated ART hospitals (88.0% and 93.3%) than the Model A and Model D (4.6% and 5.7% for CD4 cell count test, and 68.9% and 64.4% for referring to designated ART hospitals). The proportion of cases where the screening test was reactive that were commenced on ART was highest in Model C; 52.8% of cases commenced on ART compared to 38.9%, 34.2% and 21.1% in Models A, B and D respectively. Using Model A as a reference group, the multivariate logistic regression results also showed the advantages of Models B, C and D, which increased CD4 cell count test, referral to designated ART hospitals and initiation of ART, when controlling for program city and other factors. This study has demonstrated that involvement of CBOs in HIV rapid testing provision, streamlining testing and care procedures and early hospital case management can improve testing, linkage to, and retention in care and treatment among MSM in China.

  17. Project ATHENA Creates Surrogate Human Organ Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacQueen, Luke; Knospel, Fanny; Sherrod, Stacy

    2015-06-15

    The development of miniature surrogate human organs, coupled with highly sensitive mass spectrometry technologies, could one day revolutionize the way new drugs and toxic agents are studied. “By developing this ‘homo minutus,’ we are stepping beyond the need for animal or Petri dish testing: There are huge benefits in developing drug and toxicity analysis systems that can mimic the response of actual human organs,” said Rashi Iyer, a senior scientist at Los Alamos National Laboratory. ATHENA, the Advanced Tissue-engineered Human Ectypal Network Analyzer project team, is nearing the full integration of four human organ constructs — liver, heart, lung andmore » kidney — each organ component is about the size of a smartphone screen, and the whole ATHENA “body” of interconnected organs will fit neatly on a desk. A new video available on the Los Alamos National Laboratory YouTube channel updates the ATHENA project as it begins to integrate the various organ systems into a single system. Some 40 percent of pharmaceuticals fail their clinical trials and there are thousands of chemicals whose effects on humans are simply unknown. Providing a realistic, cost-effective and rapid screening system such as ATHENA with high-throughput capabilities could provide major benefits to the medical field, screening more accurately and offering a greater chance of clinical trial success. ATHENA is funded by the Defense Threat Reduction Agency (DTRA) and is a collaboration of Los Alamos National Laboratory, Harvard University, Vanderbilt University, Charité Universitätsmedizin, Berlin, Germany, CFD Research Corporation, and the University of California San Francisco.« less

  18. A rapid method for the simultaneous determination of gross alpha and beta activities in water samples using a low background liquid scintillation counter.

    PubMed

    Sanchez-Cabeza, J A; Pujol, L

    1995-05-01

    The radiological examination of water requires a rapid screening technique that permits the determination of the gross alpha and beta activities of each sample in order to decide if further radiological analyses are necessary. In this work, the use of a low background liquid scintillation system (Quantulus 1220) is proposed to simultaneously determine the gross activities in water samples. Liquid scintillation is compared to more conventional techniques used in most monitoring laboratories. In order to determine the best counting configuration of the system, pulse shape discrimination was optimized for 6 scintillant/vial combinations. It was concluded that the best counting configuration was obtained with the scintillation cocktail Optiphase Hisafe 3 in Zinsser low diffusion vials. The detection limits achieved were 0.012 Bq L-1 and 0.14 Bq L-1 for gross alpha and beta activity respectively, after a 1:10 concentration process by simple evaporation and for a counting time of only 360 min. The proposed technique is rapid, gives spectral information, and is adequate to determine gross activities according to the World Health Organization (WHO) guideline values.

  19. [Introduction of rapid syphilis and HIV testing in prenatal care in Colombia: qualitative analysis].

    PubMed

    Ochoa-Manjarrés, María Teresa; Gaitán-Duarte, Hernando Guillermo; Caicedo, Sidia; Gómez, Berta; Pérez, Freddy

    2016-12-01

    Interpret perceptions of Colombian health professionals concerning factors that obstruct and facilitate the introduction of rapid syphilis and HIV testing in prenatal care services. A qualitative study based on semi-structured interviews was carried out. A convenience sample was selected with 37 participants, who included health professionals involved in prenatal care services, programs for pregnant women, clinical laboratories, and directors of health care units or centers, as well as representatives from regional departments and the Ministry of Health. Colombia does not do widespread screening with rapid syphilis and HIV tests in prenatal care. The professionals interviewed stated they did not have prior experience in the use of rapid tests-except for laboratory staff-or in the course of action in response to a positive result. The insurance system hinders access to timely diagnosis and treatment. Health authorities perceive a need to review existing standards, strengthen the first level of care, and promote comprehensive prenatal care starting with contracts between insurers and health service institutional providers. Participants recommended staff training and integration between health-policymaking and academic entities for updating training programs. The market approach and the characteristics of the Colombian health system constitute the main barriers to implementation of rapid testing as a strategy for elimination of mother-to-child transmission of syphilis and HIV. Measures identified include making changes in contracts between insurers and health service institutional providers, adapting the timing and duration of prenatal care procedures, and training physicians and nurses involved in prenatal care.

  20. Isocratic non-aqueous reversed-phase high-performance liquid chromatographic separation of capsanthin and capsorubin in red peppers (Capsicum annuum L.), paprika and oleoresin.

    PubMed

    Weissenberg, M; Schaeffler, I; Menagem, E; Barzilai, M; Levy, A

    1997-01-03

    A simple, rapid high-performance liquid chromatography method has been devised in order to separate and quantify the xanthophylls capsorubin and capasanthin present in red pepper (Capsicum annuum L.) fruits and preparations made from them (paprika and oleoresin). A reversed-phase isocratic non-aqueous system allows the separation of xanthophylls within a few minutes, with detection at 450 nm, using methyl red as internal standard to locate the various carotenoids and xanthophylls found in plant extracts. The selection of extraction solvents, mild saponification conditions, and chromatographic features is evaluated and discussed. The method is proposed for rapid screening of large plant populations, plant selection, as well as for paprika products and oleoresin, and also for nutrition and quality control studies.

  1. Reactions in Droplets in Microfluidic Channels

    PubMed Central

    Song, Helen; Chen, Delai L.; Ismagilov, Rustem F.

    2006-01-01

    Fundamental and applied research in chemistry and biology benefits from opportunities provided by droplet-based microfluidic systems. These systems enable the miniaturization of reactions by compartmentalizing reactions in droplets of femoliter to microliter volumes. Compartmentalization in droplets provides rapid mixing of reagents, control of the timing of reactions on timescales from milliseconds to months, control of interfacial properties, and the ability to synthesize and transport solid reagents and products. Droplet-based microfluidics can help to enhance and accelerate chemical and biochemical screening, protein crystallization, enzymatic kinetics, and assays. Moreover, the control provided by droplets in microfluidic devices can lead to new scientific methods and insights. PMID:17086584

  2. Cancer CRISPR Screens In Vivo.

    PubMed

    Chow, Ryan D; Chen, Sidi

    2018-05-01

    Clustered regularly interspaced short palindromic repeats (CRISPR) screening is a powerful toolset for investigating diverse biological processes. Most CRISPR screens to date have been performed with in vitro cultures or cellular transplant models. To interrogate cancer in animal models that more closely recapitulate the human disease, autochthonous direct in vivo CRISPR screens have recently been developed that can identify causative drivers in the native tissue microenvironment. By empowering multiplexed mutagenesis in fully immunocompetent animals, direct in vivo CRISPR screens enable the rapid generation of patient-specific avatars that can guide precision medicine. This Opinion article discusses the current status of in vivo CRISPR screens in cancer and offers perspectives on future applications. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. ENCoRE: an efficient software for CRISPR screens identifies new players in extrinsic apoptosis.

    PubMed

    Trümbach, Dietrich; Pfeiffer, Susanne; Poppe, Manuel; Scherb, Hagen; Doll, Sebastian; Wurst, Wolfgang; Schick, Joel A

    2017-11-25

    As CRISPR/Cas9 mediated screens with pooled guide libraries in somatic cells become increasingly established, an unmet need for rapid and accurate companion informatics tools has emerged. We have developed a lightweight and efficient software to easily manipulate large raw next generation sequencing datasets derived from such screens into informative relational context with graphical support. The advantages of the software entitled ENCoRE (Easy NGS-to-Gene CRISPR REsults) include a simple graphical workflow, platform independence, local and fast multithreaded processing, data pre-processing and gene mapping with custom library import. We demonstrate the capabilities of ENCoRE to interrogate results from a pooled CRISPR cellular viability screen following Tumor Necrosis Factor-alpha challenge. The results not only identified stereotypical players in extrinsic apoptotic signaling but two as yet uncharacterized members of the extrinsic apoptotic cascade, Smg7 and Ces2a. We further validated and characterized cell lines containing mutations in these genes against a panel of cell death stimuli and involvement in p53 signaling. In summary, this software enables bench scientists with sensitive data or without access to informatic cores to rapidly interpret results from large scale experiments resulting from pooled CRISPR/Cas9 library screens.

  4. Metabolic Toxicity Screening Using Electrochemiluminescence Arrays Coupled with Enzyme-DNA Biocolloid Reactors and Liquid Chromatography–Mass Spectrometry

    PubMed Central

    Hvastkovs, Eli G.; Schenkman, John B.; Rusling, James F.

    2012-01-01

    New chemicals or drugs must be guaranteed safe before they can be marketed. Despite widespread use of bioassay panels for toxicity prediction, products that are toxic to a subset of the population often are not identified until clinical trials. This article reviews new array methodologies based on enzyme/DNA films that form and identify DNA-reactive metabolites that are indicators of potentially genotoxic species. This molecularly based methodology is designed in a rapid screening array that utilizes electrochemiluminescence (ECL) to detect metabolite-DNA reactions, as well as biocolloid reactors that provide the DNA adducts and metabolites for liquid chromatography–mass spectrometry (LC-MS) analysis. ECL arrays provide rapid toxicity screening, and the biocolloid reactor LC-MS approach provides a valuable follow-up on structure, identification, and formation rates of DNA adducts for toxicity hits from the ECL array screening. Specific examples using this strategy are discussed. Integration of high-throughput versions of these toxicity-screening methods with existing drug toxicity bioassays should allow for better human toxicity prediction as well as more informed decision making regarding new chemical and drug candidates. PMID:22482786

  5. Evaluation of the RAPIDEC® CARBA NP, the Rapid CARB Screen® and the Carba NP test for biochemical detection of carbapenemase-producing Enterobacteriaceae.

    PubMed

    Dortet, Laurent; Agathine, Aurélie; Naas, Thierry; Cuzon, Gaëlle; Poirel, Laurent; Nordmann, Patrice

    2015-11-01

    The objective of this study was the evaluation of the performance of two commercially available biochemical tests for the rapid detection of carbapenemase-producing Enterobacteriaceae compared with a home-made technique. A collection of 150 enterobacterial isolates, including 132 isolates with decreased susceptibility to at least one carbapenem molecule, were tested for carbapenemase activity using the RAPIDEC(®) CARBA NP (bioMérieux), the Rapid CARB Screen(®) (Rosco Diagnostica) and the home-made Carba NP test. This strain collection included 55 non-carbapenemase producers, 21 KPC producers, 21 NDM producers, 17 VIM producers, 11 IMP producers, 16 OXA-48 producers and 9 OXA-48-like producers (OXA-162, OXA-181, OXA-204, OXA-232 and OXA-244). The RAPIDEC(®) CARBA NP detected all carbapenemase producers except a single OXA-244 producer. Using the Rapid CARB Screen(®), one KPC-2, two NDM-1, one OXA-48 and five OXA-48 variant producers gave equivocal results and one OXA-244 producer was not detected. Using the Carba NP test, the same OXA-244 producer was not detected and one OXA-181 producer and one OXA-244 producer gave equivocal results. Sensitivity and specificity were 99% (95% CI 94.3%-99.8%) and 100% (95% CI 93.5%-100%), respectively, for the RAPIDEC(®) CARBA NP test, 89.5% (95% CI 81.7%-94.2%) and 70.9% (95% CI 57.9%-81.2%) for the Rapid CARB Screen(®) and 96.8% (95% CI 91.1%-98.9%) and 100% (95% CI 93.5%-100%) for the Carba NP test. The impact of the use of an adequate bacterial inoculum for obtaining the optimal performance with the RAPIDEC(®) CARBA NP was noted. The RAPIDEC(®) CARBA NP possesses the best performance for rapid and efficient detection of carbapenemase-producing Enterobacteriaceae. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Rapid Screening of Cancer Margins in Tissue with Multimodal Confocal Microscopy

    PubMed Central

    Gareau, Daniel S.; Jeon, Hana; Nehal, Kishwer S.; Rajadhyaksha, Milind

    2012-01-01

    Background Complete and accurate excision of cancer is guided by the examination of histopathology. However, preparation of histopathology is labor intensive and slow, leading to insufficient sampling of tissue and incomplete and/or inaccurate excision of margins. We demonstrate the potential utility of multimodal confocal mosaicing microscopy for rapid screening of cancer margins, directly in fresh surgical excisions, without the need for conventional embedding, sectioning or processing. Materials/Methods A multimodal confocal mosaicing microscope was developed to image basal cell carcinoma margins in surgical skin excisions, with resolution that shows nuclear detail. Multimodal contrast is with fluorescence for imaging nuclei and reflectance for cellular cytoplasm and dermal collagen. Thirtyfive excisions of basal cell carcinomas from Mohs surgery were imaged, and the mosaics analyzed by comparison to the corresponding frozen pathology. Results Confocal mosaics are produced in about 9 minutes, displaying tissue in fields-of-view of 12 mm with 2X magnification. A digital staining algorithm transforms black and white contrast to purple and pink, which simulates the appearance of standard histopathology. Mosaicing enables rapid digital screening, which mimics the examination of histopathology. Conclusions Multimodal confocal mosaicing microscopy offers a technology platform to potentially enable real-time pathology at the bedside. The imaging may serve as an adjunct to conventional histopathology, to expedite screening of margins and guide surgery toward more complete and accurate excision of cancer. PMID:22721570

  7. Rapid screening of radioactivity in food for emergency response.

    PubMed

    Bari, A; Khan, A J; Semkow, T M; Syed, U-F; Roselan, A; Haines, D K; Roth, G; West, L; Arndt, M

    2011-06-01

    This paper describes the development of methods for the rapid screening of gross alpha (GA) and gross beta (GB) radioactivity in liquid foods, specifically, Tang drink mix, apple juice, and milk, as well as screening of GA, GB, and gamma radioactivity from surface deposition on apples. Detailed procedures were developed for spiking of matrices with (241)Am (alpha radioactivity), (90)Sr/(90)Y (beta radioactivity), and (60)Co, (137)Cs, and (241)Am (gamma radioactivity). Matrix stability studies were performed for 43 days after spiking. The method for liquid foods is based upon rapid digestion, evaporation, and flaming, followed by gas proportional (GP) counting. For the apple matrix, surface radioactivity was acid-leached, followed by GP counting and/or gamma spectrometry. The average leaching recoveries from four different apple brands were between 63% and 96%, and have been interpreted on the basis of ion transport through the apple cuticle. The minimum detectable concentrations (MDCs) were calculated from either the background or method-blank (MB) measurements. They were found to satisfy the required U.S. FDA's Derived Intervention Levels (DILs) in all but one case. The newly developed methods can perform radioactivity screening in foods within a few hours and have the potential to capacity with further automation. They are especially applicable to emergency response following accidental or intentional contamination of food with radioactivity. Published by Elsevier Ltd.

  8. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    PubMed

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  9. Isolation of New Gravitropic Mutants under Hypergravity Conditions.

    PubMed

    Mori, Akiko; Toyota, Masatsugu; Shimada, Masayoshi; Mekata, Mika; Kurata, Tetsuya; Tasaka, Masao; Morita, Miyo T

    2016-01-01

    Forward genetics is a powerful approach used to link genotypes and phenotypes, and mutant screening/analysis has provided deep insights into many aspects of plant physiology. Gravitropism is a tropistic response in plants, in which hypocotyls and stems sense the direction of gravity and grow upward. Previous studies of gravitropic mutants have suggested that shoot endodermal cells in Arabidopsis stems and hypocotyls are capable of sensing gravity (i.e., statocytes). In the present study, we report a new screening system using hypergravity conditions to isolate enhancers of gravitropism mutants, and we also describe a rapid and efficient genome mapping method, using next-generation sequencing (NGS) and single nucleotide polymorphism (SNP)-based markers. Using the endodermal-amyloplast less 1 ( eal1 ) mutant, which exhibits defective development of endodermal cells and gravitropism, we found that hypergravity (10 g) restored the reduced gravity responsiveness in eal1 hypocotyls and could, therefore, be used to obtain mutants with further reduction in gravitropism in the eal1 background. Using the new screening system, we successfully isolated six ene ( enhancer of eal1 ) mutants that exhibited little or no gravitropism under hypergravity conditions, and using NGS and map-based cloning with SNP markers, we narrowed down the potential causative genes, which revealed a new genetic network for shoot gravitropism in Arabidopsis .

  10. Isolation of New Gravitropic Mutants under Hypergravity Conditions

    PubMed Central

    Mori, Akiko; Toyota, Masatsugu; Shimada, Masayoshi; Mekata, Mika; Kurata, Tetsuya; Tasaka, Masao; Morita, Miyo T.

    2016-01-01

    Forward genetics is a powerful approach used to link genotypes and phenotypes, and mutant screening/analysis has provided deep insights into many aspects of plant physiology. Gravitropism is a tropistic response in plants, in which hypocotyls and stems sense the direction of gravity and grow upward. Previous studies of gravitropic mutants have suggested that shoot endodermal cells in Arabidopsis stems and hypocotyls are capable of sensing gravity (i.e., statocytes). In the present study, we report a new screening system using hypergravity conditions to isolate enhancers of gravitropism mutants, and we also describe a rapid and efficient genome mapping method, using next-generation sequencing (NGS) and single nucleotide polymorphism (SNP)-based markers. Using the endodermal-amyloplast less 1 (eal1) mutant, which exhibits defective development of endodermal cells and gravitropism, we found that hypergravity (10 g) restored the reduced gravity responsiveness in eal1 hypocotyls and could, therefore, be used to obtain mutants with further reduction in gravitropism in the eal1 background. Using the new screening system, we successfully isolated six ene (enhancer of eal1) mutants that exhibited little or no gravitropism under hypergravity conditions, and using NGS and map-based cloning with SNP markers, we narrowed down the potential causative genes, which revealed a new genetic network for shoot gravitropism in Arabidopsis. PMID:27746791

  11. A versatile modular vector system for rapid combinatorial mammalian genetics.

    PubMed

    Albers, Joachim; Danzer, Claudia; Rechsteiner, Markus; Lehmann, Holger; Brandt, Laura P; Hejhal, Tomas; Catalano, Antonella; Busenhart, Philipp; Gonçalves, Ana Filipa; Brandt, Simone; Bode, Peter K; Bode-Lesniewska, Beata; Wild, Peter J; Frew, Ian J

    2015-04-01

    Here, we describe the multiple lentiviral expression (MuLE) system that allows multiple genetic alterations to be introduced simultaneously into mammalian cells. We created a toolbox of MuLE vectors that constitute a flexible, modular system for the rapid engineering of complex polycistronic lentiviruses, allowing combinatorial gene overexpression, gene knockdown, Cre-mediated gene deletion, or CRISPR/Cas9-mediated (where CRISPR indicates clustered regularly interspaced short palindromic repeats) gene mutation, together with expression of fluorescent or enzymatic reporters for cellular assays and animal imaging. Examples of tumor engineering were used to illustrate the speed and versatility of performing combinatorial genetics using the MuLE system. By transducing cultured primary mouse cells with single MuLE lentiviruses, we engineered tumors containing up to 5 different genetic alterations, identified genetic dependencies of molecularly defined tumors, conducted genetic interaction screens, and induced the simultaneous CRISPR/Cas9-mediated knockout of 3 tumor-suppressor genes. Intramuscular injection of MuLE viruses expressing oncogenic H-RasG12V together with combinations of knockdowns of the tumor suppressors cyclin-dependent kinase inhibitor 2A (Cdkn2a), transformation-related protein 53 (Trp53), and phosphatase and tensin homolog (Pten) allowed the generation of 3 murine sarcoma models, demonstrating that genetically defined autochthonous tumors can be rapidly generated and quantitatively monitored via direct injection of polycistronic MuLE lentiviruses into mouse tissues. Together, our results demonstrate that the MuLE system provides genetic power for the systematic investigation of the molecular mechanisms that underlie human diseases.

  12. Laser-scanning techniques for rapid ballistics identification

    NASA Technical Reports Server (NTRS)

    Woodburgy, R. C.; Nakich, R. B.

    1974-01-01

    Two different laser-scanning methods may be utilized. In each case scanned cylindrical bullet surface is displayed ""unwrapped'' on oscilloscope screen. Bullets are compared by photographing each display and superimposing negatives of two images. With some modifications bullets can be scanned and compared by superimposing images on screen of dual-beam oscilloscope.

  13. Rapid screening of oxytetracycline residue in catfish muscle by dispersive liquid-liquid microextraction and europium-sensitized luminescence

    USDA-ARS?s Scientific Manuscript database

    Oxytetracycline (OTC) residue in catfish muscle was screened by dispersive liquid-liquid microextraction (DLLME) and europium-sensitized luminescence (ESL). After extraction in EDTA, HCl, and acetonitrile, cleanup was carried out by DLLME, and ESL was measured at microgram = 385 nm and wavelength = ...

  14. Multiplex screening of persistent organic pollutants in fish using spectrally encoded microspheres

    USDA-ARS?s Scientific Manuscript database

    Persistent organic pollutants (POPs) are food contaminants of global public health concern and known to be carcinogenic and endocrine disruptors. Their monitoring is essential and an easy-to-use, rapid and affordable multi-analyte screening method with simplified sample preparation can be a valuable...

  15. Comparison of Chemical-induced Changes in Proliferation and Apoptosis in Human and Mouse Neuroprogenitor Cells.***

    EPA Science Inventory

    There is a need to develop rapid and efficient models to screen chemicals for their potential to cause developmental neurotoxicity. Use of in vitro neuronal models, including human cells, is one approach that allows for timely, cost-effective toxicity screening. The present study...

  16. A Workflow for Identifying Metabolically Active Chemicals to Complement in vitro Toxicity Screening

    EPA Science Inventory

    The new paradigm of toxicity testing approaches involves rapid screening of thousands of chemicals across hundreds of biological targets through use of in vitro assays. Such assays may lead to false negatives when the complex metabolic processes that render a chemical bioactive i...

  17. Accelerated Colorimetric Micro-assay for Screening Mold Inhibitors

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2014-01-01

    Rapid quantitative laboratory test methods are needed to screen potential antifungal agents. Existing laboratory test methods are relatively time consuming, may require specialized test equipment and rely on subjective visual ratings. A quantitative, colorimetric micro-assay has been developed that uses XTT tetrazolium salt to metabolically assess mold spore...

  18. Sensitivity of neuroprogenitor cells to chemical-induced apoptosis using a multiplexed assay suitable for high-throughput screening*

    EPA Science Inventory

    AbstractHigh-throughput methods are useful for rapidly screening large numbers of chemicals for biological activity, including the perturbation of pathways that may lead to adverse cellular effects. In vitro assays for the key events of neurodevelopment, including apoptosis, may ...

  19. Life-Stage Physiologically-Based Pharmacokinetic (PBPK) Model Applications to Screen Environmental Hazards.

    EPA Science Inventory

    This presentation discusses methods used to extrapolate from in vitro high-throughput screening (HTS) toxicity data for an endocrine pathway to in vivo for early life stages in humans, and the use of a life stage PBPK model to address rapidly changing physiological parameters. A...

  20. COMPARISON OF CHEMICAL-INDUCED CHANGES IN PROLIFERATION AND APOPTOSIS IN HUMAN AND MOUSE NEUROPROGENITOR CELLS.

    EPA Science Inventory

    There is a need to develop rapid and efficient models for screening chemicals for their potential to cause developmental neurotoxicity. Use of in vitro neuronal models, including human cells, is one approach that allows for timely, cost-effective toxicity screening. The present s...

  1. Luminescence screening of enrofloxacin and ciprofloxacin residues in swine liver after dispersive liquid - liquid microextraction cleanup

    USDA-ARS?s Scientific Manuscript database

    A rapid luminescence method was developed to screen residues of enrofloxacin (ENRO) and its metabolite, ciprofloxacin (CIPRO), in swine liver. Target analytes were extracted in acetonitrile-2.5% trifluoroacetic acid-NaCl, cleaned up by dispersive liquid-liquid microextraction (DLLME), and finally de...

  2. A CRISPR-Based Toolbox for Studying T Cell Signal Transduction

    PubMed Central

    Chi, Shen; Weiss, Arthur; Wang, Haopeng

    2016-01-01

    CRISPR/Cas9 system is a powerful technology to perform genome editing in a variety of cell types. To facilitate the application of Cas9 in mapping T cell signaling pathways, we generated a toolbox for large-scale genetic screens in human Jurkat T cells. The toolbox has three different Jurkat cell lines expressing distinct Cas9 variants, including wild-type Cas9, dCas9-KRAB, and sunCas9. We demonstrated that the toolbox allows us to rapidly disrupt endogenous gene expression at the DNA level and to efficiently repress or activate gene expression at the transcriptional level. The toolbox, in combination with multiple currently existing genome-wide sgRNA libraries, will be useful to systematically investigate T cell signal transduction using both loss-of-function and gain-of-function genetic screens. PMID:27057542

  3. Screening for infectious diseases at international airports: the Frankfurt model.

    PubMed

    Gaber, Walter; Goetsch, Udo; Diel, Roland; Doerr, Hans W; Gottschalk, René

    2009-07-01

    Historically, ships brought infectious diseases to the continents of the world, but in this modern era, infectious diseases and pandemics are primarily spread through aviation as a mode of travel. This is a significant issue in the realm of infection control because of the increased potential for the rapid worldwide transmission and spread of disease. Although the transmission of infectious diseases to airline passengers inside an aircraft is a rare occurrence, it is essential to implement entry and exit screening procedures at airports within the context of the International Health Regulations (IHR) in order to slow down the spread of infection, especially during the early phases of a pandemic event. Currently, there are no standardized procedures for health screening at airports, thus allowing individual regional authorities to determine what they deem to be appropriate screening measures for implementation. In this paper, we will discuss a new pragmatic approach for entry and exit screening procedures at international airports, propose a new classification system for contacts within the aircraft, and discuss changing the fixed enforcement of standardized community mitigation measures to the implementation of measures that correspond to specific characteristics of individual pathogenic agents. The proposed catalog of screening measures is aimed at attaining the goals of the IHR, which states that the measures should be reasonable while avoiding inconvenience or harm to passengers and should not be any more disruptive to the smooth handling of passenger traffic than is necessary.

  4. Development of an XTT tetrazolium salt-based assay for detection of specific hyperthermia sensitizers in a high-flux screening programme.

    PubMed

    Lechpammer, S; Asea, A; Mallick, R; Zhong, R; Sherman, M Y; Calderwood, S K

    2002-01-01

    It is now possible to search for new drugs using high-throughput screening of chemical libraries accumulated over the past few years. To detect potential new hyperthermia sensitizers, we are screening for chemical inhibitors of thermotolerance. For the screening of a large chemical library, a rapid and simple assay based on the XTT-tetrazolium salt with the addition of intermediate electron acceptor, phenazine methosulphate (PMS) as a promoter, was developed. It was found that the sensitivity of the XTT/PMS assay is sufficient for assessing thermal cell killing and thermotolerance, although it was highly dependent on cell number and type. When the formazan assay system was challenged with the bioflavonoid drug quercetin (up to 25mm) and validated against the clonogenic cell survival assay, significant decreases in thermotolerant cell viability were observed, directly reflecting inhibition of thermotolerance. Although short-term assays can, in some instances, underestimate overall cell killing, the dose dependency of inhibition of thermotolerance by quercetin recorded in this study by clonogenic and XTT/PMS assays was similar. Application of the XTT/PMS assay in chemical library screening was highly effective in differentiating potential thermotolerance inhibitors from both chemicals with lack of efficacy and from toxic compounds. Taken together, these results show that the XTT/PMS assay, when carried out under careful conditions, is well suited for primary high-flux screen of many thousands of compounds, thus opening up new areas for discovery of hyperthermia sensitizers.

  5. [The significance of pedigree genetic screening and rapid immunological parameters in the diagnosis of primary hemophagocytic lymphohistiocytosis].

    PubMed

    Zhang, J; Wang, Y N; Wang, J S; Wu, L; Wei, N; Fu, L; Gao, Z; Chen, J H; Pei, R J; Wang, Z

    2016-07-01

    To investigate the significance of pedigree genetic screening and rapid immunological parameters in the diagnosis of primary hemophagocytic lymphohistiocytosis (HLH). Four cases of primary HLH patients with PRF1, UNC13D and SH2D1A gene mutations were conducted pedigree investigation, including family genetic screening and detections of immunological parameters (NK cell activity, CD107a degranulation and expression of HLH related defective protein), to evaluate the significance of these different indicators in the diagnosis of primary HLH and explore their correlations. The DNA mutations of the four families included missense mutation c.T172C (p.S58P) and non- frameshift deletions c.1083_1094del (p.361_365del), missense mutation c.C1349T (p.T450M) and frameshift mutation c.1090_1091delCT (p.T364fsX93) in PRF1 gene, missense mutation c.G2588A (p.G863D) in UNC13D gene and hemizygous mutation c.32T>G (p.I11S) in SH2D1A gene. The patients and their family members presented decreased NK cell activities. Individuals who carried mutations of PRF1 gene and SH2D1A gene showed low expression of perforin (PRF1) and signaling lymphocytic activation molecule associated protein (SAP). And the patient with UNC13D gene mutation and his family member with identical mutation showed significant reducing cytotoxic degranulation function (expression of CD107a). Pedigree genetic screening and rapid detection of immunological parameters might play an important role in the diagnosis of primary HLH, and both of them had good consistency. As an efficient detection means, the rapid immunological detection indicators would provide reliable basis for the early diagnosis of the primary HLH.

  6. Perinatal and lifestyle factors mediate the association between maternal education and preschool children's weight status: the ToyBox study.

    PubMed

    Androutsos, Odysseas; Moschonis, George; Ierodiakonou, Despo; Karatzi, Kalliopi; De Bourdeaudhuij, Ilse; Iotova, Violeta; Zych, Kamila; Moreno, Luis A; Koletzko, Berthold; Manios, Yannis

    2018-04-01

    This study aimed to explore the associations among perinatal, sociodemographic, and behavioral factors and preschool overweight/obesity. Data were collected from 7541 European preschoolers in May/June 2012. Children's anthropometrics were measured, and parents self-reported all other data via questionnaires. Level of statistical significance was set at P ≤ 0.05. Certain perinatal factors (i.e., maternal prepregnancy overweight/obesity, maternal excess gestational weight gain, excess birth weight, and "rapid growth velocity"), children's energy balance-related behaviors (i.e., high sugar-sweetened beverage consumption, increased screen time, reduced active-play time), family sociodemographic characteristics (i.e., Eastern or Southern Europe, low maternal and paternal education), and parental overweight/obesity were identified as correlates of preschoolers' overweight/obesity. Furthermore, maternal prepregnancy overweight/obesity, children's "rapid growth velocity," and increased screen time mediated by 21.2%, 12.5%, and 5.7%, respectively, the association between maternal education and preschoolers' body mass index. This study highlighted positive associations of preschooler's overweight/obesity with excess maternal prepregnancy and gestational weight gain, excess birth weight and "rapid growth velocity," Southern or Eastern European region, and parental overweight/obesity. Moreover, maternal prepregnancy overweight/obesity, children's "rapid growth velocity," and increased screen time partially mediated the association between maternal education and preschoolers' body mass index. The findings of the present study may support childhood obesity prevention initiatives, because vulnerable population groups and most specifically low-educated families should be prioritized. Among other fields, these intervention initiatives should also focus on the importance of normal prepregnancy maternal weight status, normal growth velocity during infancy, and retaining preschool children's screen time within recommendations. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Neuron-specific feeding RNAi in C. elegans and its use in a screen for essential genes required for GABA neuron function.

    PubMed

    Firnhaber, Christopher; Hammarlund, Marc

    2013-11-01

    Forward genetic screens are important tools for exploring the genetic requirements for neuronal function. However, conventional forward screens often have difficulty identifying genes whose relevant functions are masked by pleiotropy. In particular, if loss of gene function results in sterility, lethality, or other severe pleiotropy, neuronal-specific functions cannot be readily analyzed. Here we describe a method in C. elegans for generating cell-specific knockdown in neurons using feeding RNAi and its application in a screen for the role of essential genes in GABAergic neurons. We combine manipulations that increase the sensitivity of select neurons to RNAi with manipulations that block RNAi in other cells. We produce animal strains in which feeding RNAi results in restricted gene knockdown in either GABA-, acetylcholine-, dopamine-, or glutamate-releasing neurons. In these strains, we observe neuron cell-type specific behavioral changes when we knock down genes required for these neurons to function, including genes encoding the basal neurotransmission machinery. These reagents enable high-throughput, cell-specific knockdown in the nervous system, facilitating rapid dissection of the site of gene action and screening for neuronal functions of essential genes. Using the GABA-specific RNAi strain, we screened 1,320 RNAi clones targeting essential genes on chromosomes I, II, and III for their effect on GABA neuron function. We identified 48 genes whose GABA cell-specific knockdown resulted in reduced GABA motor output. This screen extends our understanding of the genetic requirements for continued neuronal function in a mature organism.

  8. Rapid and accurate identification of in vivo-induced haploid seeds based on oil content in maize

    PubMed Central

    Melchinger, Albrecht E.; Schipprack, Wolfgang; Würschum, Tobias; Chen, Shaojiang; Technow, Frank

    2013-01-01

    The needs of a growing human population require rapid and efficient development of improved cultivars by plant breeders. The doubled haploid (DH) technology enables generating completely homozygous lines in a single step and, thus, is central to modern genetics and breeding approaches. Rapid and reliable identification of seeds with a haploid embryo after in vivo haploid induction is elementary in the method utilized in maize but current systems have severe shortcomings preventing their use in many germplasm types. Here, we describe an alternative method for discrimination of haploid from diploid seeds based on differences in their oil content stemming from pollination with high oil inducers. After presenting some fundamental theory, we provide a proof-of-concept with experimental results, demonstrating acceptable error rates across different germplasm. Our approach represents a breakthrough in DH technology in maize, because it is amenable to automated high-throughput screening and applicable to any maize germplasm worldwide. PMID:23820577

  9. Electrochemical Biosensor for Rapid and Sensitive Detection of Magnetically Extracted Bacterial Pathogens

    PubMed Central

    Setterington, Emma B.; Alocilja, Evangelyn C.

    2012-01-01

    Biological defense and security applications demand rapid, sensitive detection of bacterial pathogens. This work presents a novel qualitative electrochemical detection technique which is applied to two representative bacterial pathogens, Bacillus cereus (as a surrogate for B. anthracis) and Escherichia coli O157:H7, resulting in detection limits of 40 CFU/mL and 6 CFU/mL, respectively, from pure culture. Cyclic voltammetry is combined with immunomagnetic separation in a rapid method requiring approximately 1 h for presumptive positive/negative results. An immunofunctionalized magnetic/polyaniline core/shell nano-particle (c/sNP) is employed to extract target cells from the sample solution and magnetically position them on a screen-printed carbon electrode (SPCE) sensor. The presence of target cells significantly inhibits current flow between the electrically active c/sNPs and SPCE. This method has the potential to be adapted for a wide variety of target organisms and sample matrices, and to become a fully portable system for routine monitoring or emergency detection of bacterial pathogens. PMID:25585629

  10. Immobilized magnetic beads-based multi-target affinity selection coupled with HPLC-MS for screening active compounds from traditional Chinese medicine and natural products.

    PubMed

    Chen, Yaqi; Chen, Zhui; Wang, Yi

    2015-01-01

    Screening and identifying active compounds from traditional Chinese medicine (TCM) and other natural products plays an important role in drug discovery. Here, we describe a magnetic beads-based multi-target affinity selection-mass spectrometry approach for screening bioactive compounds from natural products. Key steps and parameters including activation of magnetic beads, enzyme/protein immobilization, characterization of functional magnetic beads, screening and identifying active compounds from a complex mixture by LC/MS, are illustrated. The proposed approach is rapid and efficient in screening and identification of bioactive compounds from complex natural products.

  11. [Rapid analysis of metronidazole tablets by optic-fiber sensing technologies and the similarity of ultraviolet spectra].

    PubMed

    Jin, Lu; Li, Li; Li, Xin-xia; Yang, Ting; Kong, Bin; Xu, Ping-ping

    2011-02-01

    The paper is to report the development of an optic-fiber sensing technology method to analyze metronidazole tablets rapidly. In this fiber-optic sensing system, the light from source delivering to probe can be dipped into simple-handling sample solution, absorbed by the solution and reflected to the fiber-optic and detected in the detection system at last. Then the drug content can be shown in the screen from the ultraviolet absorption spectra and the consistency between that obtained by this method and that in China Pharmacopoeia can be compared. With regard to data processing, a new method is explored to identify the authenticity of drugs using the similarity between the sample map and the standard pattern by full ultraviolet spectrum. The results indicate that ultraviolet spectra of tablets can be obtained from this technology and the determination results showed no significant difference as compared with the method in China Pharmacopoeia (P > 0.05), and the similarity can be a parameter to identify the authenticity of drugs.

  12. Development of a Novel, Bicombinatorial Approach to Alloy Development, and Application to Rapid Screening of Creep Resistant Titanium Alloys

    NASA Astrophysics Data System (ADS)

    Martin, Brian

    Combinatorial approaches have proven useful for rapid alloy fabrication and optimization. A new method of producing controlled isothermal gradients using the Gleeble Thermomechanical simulator has been developed, and demonstrated on the metastable beta-Ti alloy beta-21S, achieving a thermal gradient of 525-700 °C. This thermal gradient method has subsequently been coupled with existing combinatorial methods of producing composition gradients using the LENS(TM) additive manufacturing system, through the use of elemental blended powders. This has been demonstrated with a binary Ti-(0-15) wt% Cr build, which has subsequently been characterized with optical and electron microscopy, with special attention to the precipitate of TiCr2 Laves phases. The TiCr2 phase has been explored for its high temperature mechanical properties in a new oxidation resistant beta-Ti alloy, which serves as a demonstration of the new bicombinatorial methods developed as applied to a multicomponent alloy system.

  13. Rapid screening of serum-free media for the growth of adherent Vero cells by using a small-scale and non-invasive tool.

    PubMed

    Petiot, Emma; Fournier, Frantz; Gény, Cécile; Pinton, Hervé; Marc, Annie

    2010-03-01

    The paper proposes a rapid screening method for a first step improvement of an animal component-free medium dedicated to the growth of the anchorage-dependent Vero cell line. A new, rapid, and non-invasive technique is presented to specifically monitor cultures of adherent cells in 96-well plates. The operating conditions of an image analyzer are adapted to take into account the decrease of cell size when the attached cell density increases. An experimental design is carried out to assess the influence of ten component groups in the original medium. Two groups including protein extracts, growth factor, insulin, glucose, and pyruvate show significant positive effects. The groups with vitamins and molecules related to nitrogenous bases display a less pronounced influence. The mixture of amino acids, B(1) vitamin, magnesium sulfate, and sodium phosphate as well as the couple sodium citrate and ferric chloride lead to a downward trend. The screening results are proved to be scalable in stirred cultures with cells on microcarriers. An improved serum-free medium, with some component groups being removed or added, can be rapidly formulated to reach respectively similar or 1.6 times higher cell density than in the original medium. The results from this global approach could be helpful to further focus experiments on identified medium components.

  14. Development of an endoscopic fluorescence image-guided OCT probe for oral cancer detection

    NASA Astrophysics Data System (ADS)

    McNichols, Roger J.; Gowda, Ashok; Bell, Brent A.; Johnigan, Richard M.; Calhoun, Karen H.; Motamedi, Massoud

    2001-06-01

    Oral squamous cell carcinoma is a disease which progresses through a number of well-defined morphological and biochemical changes. Optical coherence tomography (OCT) is a rapidly-evolving, non-invasive imaging modality which allows detailed probing of subsurface tissue structures with resolution on the order of microns. While this technique offers tremendous potential as a diagnostic tool for detection and characterization of oral cancer, OCT imaging is presently associated with a field of view on the order of millimeters, and acquisition time on the order of seconds. Thus, OCT's utility as a rapid cancer screening technique is presently limited. On the other hand, imaging of tissue autofluorescence provides a very rapid, high-throughput method for cancer screening. However, while autofluorescence measures may be sensitive to cancer, they are often non- specific and lead to a large number of false positives. In the present work, we have developed a fluorescence image guided optical coherence tomographic (FIG-OCT) probe in which tissue autofluorescence images are simultaneously used to guide OCT image acquisition of suspicious regions in real time. We have begun pre-clinical pilot studies with this instrument in a DMBA-induced model of oral cancer in the hamster cheek pouch. Initial results indicate that the FIG- OCT approach shows promise as a rapid and effective tool for screening of oral cancer.

  15. Multiplex titration RT-PCR: rapid determination of gene expression patterns for a large number of genes

    NASA Technical Reports Server (NTRS)

    Nebenfuhr, A.; Lomax, T. L.

    1998-01-01

    We have developed an improved method for determination of gene expression levels with RT-PCR. The procedure is rapid and does not require extensive optimization or densitometric analysis. Since the detection of individual transcripts is PCR-based, small amounts of tissue samples are sufficient for the analysis of expression patterns in large gene families. Using this method, we were able to rapidly screen nine members of the Aux/IAA family of auxin-responsive genes and identify those genes which vary in message abundance in a tissue- and light-specific manner. While not offering the accuracy of conventional semi-quantitative or competitive RT-PCR, our method allows quick screening of large numbers of genes in a wide range of RNA samples with just a thermal cycler and standard gel analysis equipment.

  16. Rapid in vivo testing of drug response in multiple myeloma made possible by xenograft to turkey embryos

    PubMed Central

    Farnoushi, Y; Cipok, M; Kay, S; Jan, H; Ohana, A; Naparstek, E; Goldstein, R S; Deutsch, V R

    2011-01-01

    Background: The best current xenograft model of multiple myeloma (MM) in immune-deficient non-obese diabetic/severe-combined immunodeficient mice is costly, animal maintenance is complex and several weeks are required to establish engraftment and study drug efficacy. More practical in vivo models may reduce time and drug development cost. We recently described a rapid low-cost xenograft model of human blood malignancies in pre-immune turkey. Here, we report application of this system for studying MM growth and the preclinical assessment of anticancer therapies. Methods: Cell lines and MM patient cells were injected intravenously into embryonic veins on embryonic day 11 (E11). Engraftment of human cells in haematopoietic organs was detected by quantitative real-time polymerase chain reaction, immunohistochemistry, flow cytometry and circulating free light chain. Results: Engraftment was detected after 1 week in all embryos injected with cell lines and in 50% of those injected with patient cells. Injection of bortezomib or lenalinomide 48 h after cell injection at therapeutic levels that were not toxic to the bone marrow dramatically reduced MM engraftment. Conclusion: The turkey embryo provides a practical, xenograft system to study MM and demonstrates the utility of this model for rapid and affordable testing therapeutics in vivo. With further development, this model may enable rapid, inexpensive personalised drug screening. PMID:22045188

  17. Optical tools for high-throughput screening of abrasion resistance of combinatorial libraries of organic coatings

    NASA Astrophysics Data System (ADS)

    Potyrailo, Radislav A.; Chisholm, Bret J.; Olson, Daniel R.; Brennan, Michael J.; Molaison, Chris A.

    2002-02-01

    Design, validation, and implementation of an optical spectroscopic system for high-throughput analysis of combinatorially developed protective organic coatings are reported. Our approach replaces labor-intensive coating evaluation steps with an automated system that rapidly analyzes 8x6 arrays of coating elements that are deposited on a plastic substrate. Each coating element of the library is 10 mm in diameter and 2 to 5 micrometers thick. Performance of coatings is evaluated with respect to their resistance to wear abrasion because this parameter is one of the primary considerations in end-use applications. Upon testing, the organic coatings undergo changes that are impossible to quantitatively predict using existing knowledge. Coatings are abraded using industry-accepted abrasion test methods at single-or multiple-abrasion conditions, followed by high- throughput analysis of abrasion-induced light scatter. The developed automated system is optimized for the analysis of diffusively scattered light that corresponds to 0 to 30% haze. System precision of 0.1 to 2.5% relative standard deviation provides capability for the reliable ranking of coatings performance. While the system was implemented for high-throughput screening of combinatorially developed organic protective coatings for automotive applications, it can be applied to a variety of other applications where materials ranking can be achieved using optical spectroscopic tools.

  18. T-scan III system diagnostic tool for digital occlusal analysis in orthodontics - a modern approach.

    PubMed

    Trpevska, Vesna; Kovacevska, Gordana; Benedeti, Alberto; Jordanov, Bozidar

    2014-01-01

    This systematic literature review was performed to establish the mechanism, methodology, characteristics, clinical application and opportunities of the T-Scan III System as a diagnostic tool for digital occlusal analysis in different fields of dentistry, precisely in orthodontics. Searching of electronic databases, using MEDLINE and PubMed, hand searching of relevant key journals, and screening of reference lists of included studies with no language restriction was performed. Publications providing statistically examined data were included for systematic review. Twenty potentially relevant Randomized Controlled Trials (RCTs) were identified. Only ten met the inclusion criteria. The literature demonstrates that using digital occlusal analysis with T-Scan III System in orthodontics has significant advantage with regard to the capability of measuring occlusal parameters in static positions and during dynamic of the mandible. Within the scope of this systematic review, there is evidence to support that T-Scan system is rapid and accurate in identifying the distribution of the tooth contacts and it shows great promise as a clinical diagnostic screening device for occlusion and for improving the occlusion after various dental treatments. Additional clinical studies are required to advance the indication filed of this system. Importance of using digital occlusal T-Scan analysis in orthodontics deserves further investigation.

  19. Serological survey of HIV and syphilis in pregnant women in Madagascar.

    PubMed

    Frickmann, Hagen; Schwarz, Norbert G; Girmann, Mirko; Hagen, Ralf M; Poppert, Sven; Crusius, Sabine; Podbielski, Andreas; Heriniaina, Jean N; Razafindrabe, Tsiriniaina; Rakotondrainiarivelo, Jean P; May, Jürgen; Rakotozandrindrainy, Raphaël

    2013-01-01

    Peripartal transmission of human immunodeficiency virus (HIV) and Treponema pallidum, the causative agent of syphilis, leads to severe consequences for newborns. Preventive measures require awareness of the maternal infection. Although HIV and syphilis testing in Madagascar could be theoretically carried out within the framework of the national pregnancy follow-up scheme, the required test kits are rarely available at peripheral health centres. In this study, we screened blood samples of pregnant Madagascan women for HIV and syphilis seroprevalence to estimate the demand for systemic screening in pregnancy. Retrospective anonymous serological analysis for HIV and syphilis was performed in plasma samples from 1232 pregnant women that were taken between May and July 2010 in Ambositra, Ifanadiana, Manakara, Mananjary, Moramanga and Tsiroanomandidy (Madagascar) during pregnancy follow-up. Screening was based on Treponema pallidum haemagglutination tests for syphilis and rapid tests for HIV, with confirmation of positive screening results on line assays. Out of 1232 pregnant women, none were seropositive for HIV and 37 (3%) were seropositive for Treponema pallidum. Our findings are in line with previous studies that describe considerable syphilis prevalence in the rural Madagascan population. The results suggest a need for screening to prevent peripartal Treponema pallidum transmission, while HIV is still rare. If they are known, Treponema pallidum infections can be easily, safely and inexpensively treated even in pregnancy to reduce the risk of transmission. © 2012 Blackwell Publishing Ltd.

  20. Case study: technology initiative led to advanced lead optimization screening processes at Bristol-Myers Squibb, 2004-2009.

    PubMed

    Zhang, Litao; Cvijic, Mary Ellen; Lippy, Jonathan; Myslik, James; Brenner, Stephen L; Binnie, Alastair; Houston, John G

    2012-07-01

    In this paper, we review the key solutions that enabled evolution of the lead optimization screening support process at Bristol-Myers Squibb (BMS) between 2004 and 2009. During this time, technology infrastructure investment and scientific expertise integration laid the foundations to build and tailor lead optimization screening support models across all therapeutic groups at BMS. Together, harnessing advanced screening technology platforms and expanding panel screening strategy led to a paradigm shift at BMS in supporting lead optimization screening capability. Parallel SAR and structure liability relationship (SLR) screening approaches were first and broadly introduced to empower more-rapid and -informed decisions about chemical synthesis strategy and to broaden options for identifying high-quality drug candidates during lead optimization. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. REVIEW OF RAPID METHODS FOR ASSESSING WETLAND CONDITION

    EPA Science Inventory

    We evaluated over 40 wetland rapid assessment methods developed for a variety of purposes for their use in the assessment of ecological integrity or ecosystem condition. Four criteria were used to screen methods: 1) the method can be used to measure condition, 2) it is truly rap...

  2. Using pre-screening methods for an effective and reliable site characterization at megasites.

    PubMed

    Algreen, Mette; Kalisz, Mariusz; Stalder, Marcel; Martac, Eugeniu; Krupanek, Janusz; Trapp, Stefan; Bartke, Stephan

    2015-10-01

    This paper illustrates the usefulness of pre-screening methods for an effective characterization of polluted sites. We applied a sequence of site characterization methods to a former Soviet military airbase with likely fuel and benzene, toluene, ethylbenzene, and xylene (BTEX) contamination in shallow groundwater and subsoil. The methods were (i) phytoscreening with tree cores; (ii) soil gas measurements for CH4, O2, and photoionization detector (PID); (iii) direct-push with membrane interface probe (MIP) and laser-induced fluorescence (LIF) sensors; (iv) direct-push sampling; and (v) sampling from soil and from groundwater monitoring wells. Phytoscreening and soil gas measurements are rapid and inexpensive pre-screening methods. Both indicated subsurface pollution and hot spots successfully. The direct-push sensors yielded 3D information about the extension and the volume of the subsurface plume. This study also expanded the applicability of tree coring to BTEX compounds and tested the use of high-resolution direct-push sensors for light hydrocarbons. Comparison of screening results to results from conventional soil and groundwater sampling yielded in most cases high rank correlation and confirmed the findings. The large-scale application of non- or low-invasive pre-screening can be of help in directing and focusing the subsequent, more expensive investigation methods. The rapid pre-screening methods also yielded useful information about potential remediation methods. Overall, we see several benefits of a stepwise screening and site characterization scheme, which we propose in conclusion.

  3. Development and Validation of a High Throughput System for Discovery of Antigens for Autoantibody Detection

    PubMed Central

    Macdonald, Isabel K.; Allen, Jared; Murray, Andrea; Parsy-Kowalska, Celine B.; Healey, Graham F.; Chapman, Caroline J.; Sewell, Herbert F.; Robertson, John F. R.

    2012-01-01

    An assay employing a panel of tumor-associated antigens has been validated and is available commercially (EarlyCDT®-Lung) to aid the early detection of lung cancer by measurement of serum autoantibodies. The high throughput (HTP) strategy described herein was pursued to identify new antigens to add to the EarlyCDT-Lung panel and to assist in the development of new panels for other cancers. Two ligation-independent cloning vectors were designed and synthesized, producing fusion proteins suitable for the autoantibody ELISA. We developed an abridged HTP version of the validated autoantibody ELISA, determining that results reflected the performance of the EarlyCDT assay, by comparing results on both formats. Once validated this HTP ELISA was utilized to screen multiple fusion proteins prepared on small-scale, by a HTP expression screen. We determined whether the assay performance for these HTP protein batches was an accurate reflection of the performance of R&D or commercial batches. A HTP discovery platform for the identification and optimal production of tumor- associated antigens which detects autoantibodies has been developed and validated. The most favorable conditions for the exposure of immunogenic epitopes were assessed to produce discriminatory proteins for use in a commercial ELISA. This process is rapid and cost-effective compared to standard cloning and screening technologies and enables rapid advancement in the field of autoantibody assay discovery. This approach will significantly reduce timescale and costs for developing similar panels of autoantibody assays for the detection of other cancer types with the ultimate aim of improved overall survival due to early diagnosis and treatment. PMID:22815807

  4. Rapid screening of transferrin-binders in the flowers of Bauhinia blakeana Dunn by on-line high-performance liquid chromatography-diode-array detector-electrospray ionization-ion-trap-time-of-flight-mass spectrometry-transferrin-fluorescence detection system.

    PubMed

    Liu, Meixian; Dong, Jing; Lin, Zongtao; Niu, Yanyan; Zhang, Xiaotian; Jiang, Haixiu; Guo, Ning; Li, Wei; Wang, Hong; Chen, Shizhong

    2016-06-10

    Transferrin (Transferrin, TRF, TF) has drawn increasing attention in cancer therapy due to its potential applications in drug delivery. TF receptor, highly expressed in tumor cells, recognizes and transports Fe(3+)-TF into cells to release iron into cytoplasm. Thus, discovering TF-binding compounds has become an active research area and is of great importance for target therapy. In this study, an on-line analysis method was established for screening TF-binding compounds from the flowers of Bauhinia blakeana Dunn using a high-performance liquid chromatography-diode-array detector-multi-stage mass spectrometry-transferrin-fluorescence detector (HPLC-DAD-MS(n)-TF-FLD) method. As a result, 33 of 80 identified or tentatively characterized compounds in the sample were TF-binding active. Twenty-five flavonol glycosides and eight phenolic acids were identified as TF-binders. Twelve of these active compounds together with six standard compounds were used to study the dose-response effects and structure-activity relationships of flavonoids and phenolic acids. The method was validated by vitexin with a good linearity in the range of concentrations used in the study. The limit of detection for vitexin was 0.1596 nmol. Our study indicated that the established method is simple, rapid and sensitive for screening TF-binding active compounds in the extract of Bauhinia blakeana Dunn, and therefore is important for discovering potential anti-cancer ingredients from complex samples for TF related drug delivery. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Genetic and epigenetic control of gene expression by CRISPR–Cas systems

    PubMed Central

    Lo, Albert; Qi, Lei

    2017-01-01

    The discovery and adaption of bacterial clustered regularly interspaced short palindromic repeats (CRISPR)–CRISPR-associated (Cas) systems has revolutionized the way researchers edit genomes. Engineering of catalytically inactivated Cas variants (nuclease-deficient or nuclease-deactivated [dCas]) combined with transcriptional repressors, activators, or epigenetic modifiers enable sequence-specific regulation of gene expression and chromatin state. These CRISPR–Cas-based technologies have contributed to the rapid development of disease models and functional genomics screening approaches, which can facilitate genetic target identification and drug discovery. In this short review, we will cover recent advances of CRISPR–dCas9 systems and their use for transcriptional repression and activation, epigenome editing, and engineered synthetic circuits for complex control of the mammalian genome. PMID:28649363

  6. A rapid screening with direct sequencing from blood samples for the diagnosis of Leigh syndrome.

    PubMed

    Shimbo, Hiroko; Takagi, Mariko; Okuda, Mitsuko; Tsuyusaki, Yu; Takano, Kyoko; Iai, Mizue; Yamashita, Sumimasa; Murayama, Kei; Ohtake, Akira; Goto, Yu-Ichi; Aida, Noriko; Osaka, Hitoshi

    2014-01-01

    Large numbers of genes are responsible for Leigh syndrome (LS), making genetic confirmation of LS difficult. We screened our patients with LS using a limited set of 21 primers encompassing the frequently reported gene for the respiratory chain complexes I (ND1-ND6, and ND4L), IV(SURF1), and V(ATP6) and the pyruvate dehydrogenase E1α-subunit. Of 18 LS patients, we identified mutations in 11 patients, including 7 in mDNA (two with ATP6), 4 in nuclear (three with SURF1). Overall, we identified mutations in 61% of LS patients (11/18 individuals) in this cohort. Sanger sequencing with our limited set of primers allowed us a rapid genetic confirmation of more than half of the LS patients and it appears to be efficient as a primary genetic screening in this cohort.

  7. Screening of nerve agent degradation products by MALDI-TOFMS.

    PubMed

    Shu, You-Ren; Su, An-Kai; Liu, Ju-Tsung; Lin, Cheng-Huang

    2006-07-01

    A novel method for the rapid screening of degradation products derived from nerve agents by matrix-assisted laser desorption ionization time-of-flight mass spectrometry is described. Five standard products were selected as model compounds, including isopropyl methylphosphonic acid (IMPA), pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), isobutyl methylphosphonic acid (i-BuMPA), and cyclohexyl methylphosphonic acid (CHMPA), which are degradation products of Sarin (GB), Soman (GD), VX, Russian VX (RVX), and GF, respectively. For comparison, CHCA (alpha-cyano-4-hydroxycinnamic acid) and DCCA (7-(diethylamino)coumarin-3-carboxylic acid) were used as the MALDI-matrix when the third harmonic generation (355 nm) of a Nd:YAG laser and a hydrogen Raman laser (multifrequency laser) were used, respectively. The method permitted the five nerve agent degradation products to be screened rapidly and successfully, suggesting that it has the potential for use as a routine monitoring tool.

  8. Automated 100-Position Specimen Loader and Image Acquisition System for Transmission Electron Microscopy

    PubMed Central

    Lefman, Jonathan; Morrison, Robert; Subramaniam, Sriram

    2007-01-01

    We report the development of a novel, multi-specimen imaging system for high-throughput transmission electron microscopy. Our cartridge-based loading system, called the “Gatling”, permits the sequential examination of as many as 100 specimens in the microscope for room temperature electron microscopy using mechanisms for rapid and automated specimen exchange. The software for the operation of the Gatling and automated data acquisition has been implemented in an updated version of our in-house program AutoEM. In the current implementation of the system, the time required to deliver 95 specimens into the microscope and collect overview images from each is about 13 hours. Regions of interest are identified from a low magnification atlas generation from each specimen and an unlimited number of higher magnifications images can be subsequently acquired from these regions using fully automated data acquisition procedures that can be controlled from a remote interface. We anticipate that the availability of the Gatling will greatly accelerate the speed of data acquisition for a variety of applications in biology, materials science and nanotechnology that require rapid screening and image analysis of multiple specimens. PMID:17240161

  9. Dual genetic selection of synthetic riboswitches in Escherichia coli.

    PubMed

    Nomura, Yoko; Yokobayashi, Yohei

    2014-01-01

    This chapter describes a genetic selection strategy to engineer synthetic riboswitches that can chemically regulate gene expression in Escherichia coli. Riboswitch libraries are constructed by randomizing the nucleotides that potentially comprise an expression platform and fused to the hybrid selection/screening marker tetA-gfpuv. Iterative ON and OFF selections are performed under appropriate conditions that favor the survival or the growth of the cells harboring the desired riboswitches. After the selection, rapid screening of individual riboswitch clones is performed by measuring GFPuv fluorescence without subcloning. This optimized dual genetic selection strategy can be used to rapidly develop synthetic riboswitches without detailed computational design or structural knowledge.

  10. Paper-based microfluidic sensing device for label-free immunoassay demonstrated by biotin-avidin binding interaction.

    PubMed

    Lei, Kin Fong; Yang, Shih-I; Tsai, Shiao-Wen; Hsu, Hsiao-Ting

    2015-03-01

    Efficient diagnosis is very important for the prevention and treatment of diseases. Rapid disease screening in ambulatory environment is one of the most pressing needs for disease control. Despite there are many methods to detect the results of immunoassays, quantitative measurement for rapid disease screening is still a great challenge for point-of-care applications. In this study, a fabrication method for depositing carbon nanotube bundles has been successfully developed for realization of functional paper-based microfluidic sensing device. Quantitative detection of label-free immunoassay, i.e., biotin-avidin binding interaction, was demonstrated by direct measurement of the current change of the biosensor after single application of the target analyte. Sensitivity of 0.33 μA/ng mL(-1) and minimal detectable analyte concentration of 25 ng/mL were achieved. The time necessary for the detection was 500 s which is a large reduction compared with the conventional immunoassay. Such paper-based biosensor has the benefits of portability, fast response, simple operation, and low cost and has the potential for the development of rapid disease screening devices. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Hollow fiber based affinity selection combined with high performance liquid chromatography-mass spectroscopy for rapid screening lipase inhibitors from lotus leaf.

    PubMed

    Tao, Yi; Zhang, Yufeng; Wang, Yi; Cheng, Yiyu

    2013-06-27

    A novel kind of immobilized enzyme affinity selection strategy based on hollow fibers has been developed for screening inhibitors from extracts of medicinal plants. Lipases from porcine pancreas were adsorbed onto the surface of polypropylene hollow fibers to form a stable matrix for ligand fishing, which was called hollow fibers based affinity selection (HF-AS). A variety of factors related to binding capability, including enzyme concentration, incubation time, temperature, buffer pH and ion strength, were optimized using a known lipase inhibitor hesperidin. The proposed approach was applied in screening potential lipase bound ligands from extracts of lotus leaf, followed by rapid characterization of active compounds using high performance liquid chromatography-mass spectrometry. Three flavonoids including quercetin-3-O-β-D-arabinopyranosyl-(1→2)-β-D-galactopyranoside, quercetin-3-O-β-D-glucuronide and kaempferol-3-O-β-d-glucuronide were identified as lipase inhibitors by the proposed HF-AS approach. Our findings suggested that the hollow fiber-based affinity selection could be a rapid and convenient approach for drug discovery from natural products resources. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. High resolution melting analytical platform for rapid prenatal and postnatal diagnosis of β-thalassemia common among Southeast Asian population.

    PubMed

    Prajantasen, Thanet; Fucharoen, Supan; Fucharoen, Goonnapa

    2015-02-20

    High resolution melting (HRM) analysis is a powerful technology for scanning sequence alteration. We have applied this HRM assay to screen common β-thalassemia mutations found among Southeast Asian population. Known DNA samples with 8 common mutations were used in initial development of the methods including -28 A-G, codon 17 A-T, IVSI-1G-T, IVSI-5G-C, codon 26G-A (Hb E), codons 41/42 -TTCT, codons 71/72+A and IVSII-654 C-T. Further validation was done on 60 postnatal and 6 prenatal diagnoses of β-thalassemia. Each mutation has specific HRM profile which could be used in rapid screening. Apart from those with DNA deletions, the results of HRM assay matched 100% with those of routine diagnosis made by routine allele specific PCR. In addition, the HRM assay could initially recognize three unknown mutations including a hitherto un-described one in Thai population. The established HRM assay should prove useful for rapid and high throughput platform for screening and prenatal diagnosis of β-thalassemia common in the region. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. An image based vibration sensor for soft tissue modal analysis in a Digital Image Elasto Tomography (DIET) system.

    PubMed

    Feng, Sheng; Lotz, Thomas; Chase, J Geoffrey; Hann, Christopher E

    2010-01-01

    Digital Image Elasto Tomography (DIET) is a non-invasive elastographic breast cancer screening technology, based on image-based measurement of surface vibrations induced on a breast by mechanical actuation. Knowledge of frequency response characteristics of a breast prior to imaging is critical to maximize the imaging signal and diagnostic capability of the system. A feasibility analysis for a non-invasive image based modal analysis system is presented that is able to robustly and rapidly identify resonant frequencies in soft tissue. Three images per oscillation cycle are enough to capture the behavior at a given frequency. Thus, a sweep over critical frequency ranges can be performed prior to imaging to determine critical imaging settings of the DIET system to optimize its tumor detection performance.

  14. 77 FR 37415 - Office of Urban Indian Health Programs; Title V HIV/AIDS Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... population. This will provide routine and/or rapid HIV screening, prevention, and pre- and post-test... as per 2006 Centers for Disease Control and Prevention (CDC) guidelines and pre- and post-test... choose to bundle HIV tests with sexually transmitted disease (STD) screening. II. Award Information Type...

  15. 77 FR 36557 - Office of Urban Indian Health Programs Funding Opportunity: Title V HIV/AIDS Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    .... This will provide routine and/or rapid HIV screening, prevention, and pre- and post-test counseling... 2006 Centers for Disease Control and Prevention (CDC) guidelines and pre- and post-test counseling... choose to bundle HIV tests with sexually transmitted disease (STD) screening. II. Award Information Type...

  16. Colorimetric micro-assay for accelerated screening of mould inhibitors

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2013-01-01

    Since current standard laboratory methods are time-consuming macro-assays that rely on subjective visual ratings of mould growth, rapid and quantitative laboratory methods are needed to screen potential mould inhibitors for use in and on cellulose-based products. A colorimetric micro-assay has been developed that uses XTT tetrazolium salt to enzymatically assess...

  17. Screening Hospitalized Patients for Low Health Literacy: Beyond the REALM of Possibility?

    ERIC Educational Resources Information Center

    Louis, Allison J.; Arora, Vineet M.; Matthiesen, Madeleine I.; Meltzer, David O.; Press, Valerie G.

    2017-01-01

    As patient-centered education efforts increase, assessing health literacy (HL) becomes more salient. The verbal Brief Health Literacy Screen (BHLS) may have clinical and feasibility advantages over written tools, including the Rapid Estimate of Adult Literacy in Medicine--Revised (REALM-R) and Short Test of Functional Health Literacy in Adults…

  18. Fragment-Based Phenotypic Lead Discovery: Cell-Based Assay to Target Leishmaniasis.

    PubMed

    Ayotte, Yann; Bilodeau, François; Descoteaux, Albert; LaPlante, Steven R

    2018-05-02

    A rapid and practical approach for the discovery of new chemical matter for targeting pathogens and diseases is described. Fragment-based phenotypic lead discovery (FPLD) combines aspects of traditional fragment-based lead discovery (FBLD), which involves the screening of small-molecule fragment libraries to target specific proteins, with phenotypic lead discovery (PLD), which typically involves the screening of drug-like compounds in cell-based assays. To enable FPLD, a diverse library of fragments was first designed, assembled, and curated. This library of soluble, low-molecular-weight compounds was then pooled to expedite screening. Axenic cultures of Leishmania promastigotes were screened, and single hits were then tested for leishmanicidal activity against intracellular amastigote forms in infected murine bone-marrow-derived macrophages without evidence of toxicity toward mammalian cells. These studies demonstrate that FPLD can be a rapid and effective means to discover hits that can serve as leads for further medicinal chemistry purposes or as tool compounds for identifying known or novel targets. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. [Screening and confirmation of 24 hormones in cosmetics by ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry].

    PubMed

    Li, Zhaoyong; Wang, Fengmei; Niu, Zengyuan; Luo, Xin; Zhang, Gang; Chen, Junhui

    2014-05-01

    A method of ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UPLC-LTQ/Orbitrap MS) was established to screen and confirm 24 hormones in cosmetics. Various cosmetic samples were extracted with methanol. The extract was loaded onto a Waters ACQUITY UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 microm) using a gradient elution of acetonitrile/water containing 0.1% (v/v) formic acid for the separation. The accurate mass of quasi-molecular ion was acquired by full scanning of electrostatic field orbitrap. The rapid screening was carried out by the accurate mass of quasi-molecular ion. The confirmation analysis for targeted compounds was performed with the retention time and qualitative fragments obtained by data dependent scan mode. Under the optimal conditions, the 24 hormones were routinely detected with mass accuracy error below 3 x 10(-6) (3 ppm), and good linearities were obtained in their respective linear ranges with correlation coefficients higher than 0.99. The LODs (S/N = 3) of the 24 compounds were < or = 10 microg/kg, which can meet the requirements for the actual screening of cosmetic samples. The developed method was applied to screen the hormones in 50 cosmetic samples. The results demonstrate that the method is a useful tool for the rapid screening and identification of the hormones in cosmetics.

  20. Evaluative reports on medical malpractice policies in obstetrics: a rapid scoping review.

    PubMed

    Cardoso, Roberta; Zarin, Wasifa; Nincic, Vera; Barber, Sarah Louise; Gulmezoglu, Ahmet Metin; Wilson, Charlotte; Wilson, Katherine; McDonald, Heather; Kenny, Meghan; Warren, Rachel; Straus, Sharon E; Tricco, Andrea C

    2017-09-06

    The clinical specialty of obstetrics is under particular scrutiny with increasing litigation costs and unnecessary tests and procedures done in attempts to prevent litigation. We aimed to identify reports evaluating or comparing the effectiveness of medical liability reforms and quality improvement strategies in improving litigation-related outcomes in obstetrics. We conducted a rapid scoping review with a 6-week timeline. MEDLINE, EMBASE, LexisNexis Academic, the Legal Scholarship Network, Justis, LegalTrac, QuickLaw, and HeinOnline were searched for publications in English from 2004 until June 2015. The selection criteria for screening were established a priori and pilot-tested. We included reports comparing or evaluating the impact of obstetrics-related medical liability reforms and quality improvement strategies on cost containment and litigation settlement across all countries. All levels of screening were done by two reviewers independently, and discrepancies were resolved by a third reviewer. In addition, two reviewers independently extracted relevant data using a pre-tested form, and discrepancies were resolved by a third reviewer. The results were summarized descriptively. The search resulted in 2729 citations, of which 14 reports met our eligibility criteria. Several initiatives for improving the medical malpractice litigation system were found, including no-fault approaches, patient safety policy initiatives, communication and resolution, caps on compensation and attorney fees, alternative payment system and liabilities, and limitations on litigation. Only a few litigation policies in obstetrics were evaluated or compared. Included documents showed that initiatives to reduce medical malpractice litigation could be associated with a decrease in adverse and malpractice events. However, due to heterogeneous settings (e.g., economic structure, healthcare system) and variation in the outcomes reported, the advantages and disadvantages of initiatives may vary.

  1. Cell Engineering and Molecular Pharming for Biopharmaceuticals

    PubMed Central

    Abdullah, M.A; Rahmah, Anisa ur; Sinskey, A.J; Rha, C.K

    2008-01-01

    Biopharmaceuticals are often produced by recombinant E. coli or mammalian cell lines. This is usually achieved by the introduction of a gene or cDNA coding for the protein of interest into a well-characterized strain of producer cells. Naturally, each recombinant production system has its own unique advantages and disadvantages. This paper examines the current practices, developments, and future trends in the production of biopharmaceuticals. Platform technologies for rapid screening and analyses of biosystems are reviewed. Strategies to improve productivity via metabolic and integrated engineering are also highlighted. PMID:19662143

  2. NASPGHAN Clinical Practice Guideline for the Diagnosis and Treatment of Nonalcoholic Fatty Liver Disease in Children

    PubMed Central

    Vos, Miriam B.; Abrams, Stephanie H.; Barlow, Sarah E.; Caprio, Sonia; Daniels, Stephen R.; Kohli, Rohit; Mouzaki, Marialena; Sathya, Pushpa; Schwimmer, Jeffrey B.; Sundaram, Shikha S.; Xanthakos, Stavra A.

    2017-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a highly prevalent chronic liver disease that occurs in the setting of insulin resistance and increased adiposity. It has rapidly evolved into the most common liver disease seen in the pediatric population and is a management challenge for general pediatric practitioners, subspecialists and for health systems. In this guideline, the expert committee on NAFLD (ECON) reviewed and summarized the available literature, formulating recommendations to guide screening and clinical care of children with NAFLD. PMID:28107283

  3. Method and apparatus for rapid biohydrogen phenotypic screening of microorganisms using a chemochromic sensor

    DOEpatents

    Seibert, Michael; Benson, David K.; Flynn, Timothy Michael

    2001-01-01

    The invention provides an assay system for identifying a hydrogen-gas-producing organism, including a sensor film having a first layer comprising a transition metal oxide or oxysalt and a second layer comprising hydrogen-dissociative catalyst metal, the first and second layers having an inner and an outer surface wherein the inner surface of the second layer is deposited on the outer surface of the first layer, and a substrate disposed proximally to the outer surface of the second layer, the organism being isolated on the substrate.

  4. Pathophysiology, treatment, and prevention of fluid and electrolyte abnormalities during refeeding syndrome.

    PubMed

    Parli, Sara E; Ruf, Kathryn M; Magnuson, Barbara

    2014-01-01

    Refeeding syndrome may occur after the reintroduction of carbohydrates in chronically malnourished or acutely hypermetabolic patients as a result of a rapid shift to glucose utilization as an energy source. Electrolyte abnormalities of phosphorus, potassium, and magnesium occur, leading to complications of various organ systems, and may result in death. Patients should be screened for risk factors of malnutrition to prevent refeeding syndrome. For those at risk, nutrition should be initiated and slowly advanced toward the patient's goal over several days. Electrolyte disturbances should be aggressively corrected.

  5. Simple and rapid screening procedure for 143 new psychoactive substances by liquid chromatography-tandem mass spectrometry.

    PubMed

    Adamowicz, Piotr; Tokarczyk, Bogdan

    2016-07-01

    In recent years, many new psychoactive substances (NPS) from several drug classes have appeared on the drug market. These substances, also known as 'legal highs', belong to different chemical classes. Despite the increasing number of NPS, there are few comprehensive screening methods for their detection in biological specimens. In this context, the purpose of this study was to develop a fast and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening procedure for NPS in blood. The elaborated method allows the simultaneous screening of 143 compounds from different groups (number of compounds): cathinones (36), phenethylamines (26), tryptamines (18), piperazines (9), piperidines (2), synthetic cannabinoids (34), arylalkylamines (7), arylcyclohexylamines (3), aminoindanes (2), and other drugs (6). Blood samples (0.2 mL) were precipitated with acetonitrile (0.6 mL). The separation was achieved with gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 14 min. Detection of all compounds was based on multiple reaction monitoring (MRM) transitions. The total number of transitions monitored in dynamic mode was 432. The whole procedure was rapid and simple. The limits of detection (LODs) estimated for 104 compounds were in the range 0.01-3.09 ng/mL. The extraction recoveries determined for 32 compounds were from 1.8 to 133%. The procedure was successfully applied to the analysis of forensic blood samples in routine casework. The developed method should have wide applicability for rapid screening of new drugs of abuse in forensic or clinical samples. The procedure can be easily expanded for more substances. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  6. USASOC Injury Prevention/Performance Optimization Musculoskeletal Screening Initiative

    DTIC Science & Technology

    2011-11-01

    Tactical Human Optimization , Rapid Rehabilitation , and Reconditioning (THOR3) program to identify the...Special Operations Command (USASOC) to support development of USASOC’s Tactical Human Optimization , Rapid Rehabilitation , and Reconditioning (THOR3...biomechanical, musculoskeletal, physiological, tactical , and injury data and refine its current human performance program to address the

  7. Multiplex surface plasmon resonance imaging platform for label-free detection of foodborne pathogens

    USDA-ARS?s Scientific Manuscript database

    Salmonellae are among the leading causes of foodborne outbreaks in the United States, and more rapid and efficient detection methods are needed. Surface plasmon resonance imaging (SPRi) is an emerging optical technique, which allows for rapid and label-free screening of multiple targets simultaneous...

  8. Surface plasmon resonance imaging for label-free detection of foodborne pathogens and toxins

    USDA-ARS?s Scientific Manuscript database

    More rapid and efficient detection methods for foodborne pathogenic bacteria and toxins are needed to address the long assay time and limitations in multiplex capacity. Surface plasmon resonance imaging (SPRi) is an emerging optical technique, which allows for rapid and label-free screening of multi...

  9. Bacteria-powered battery on paper.

    PubMed

    Fraiwan, Arwa; Choi, Seokheun

    2014-12-21

    Paper-based devices have recently emerged as simple and low-cost paradigms for fluid manipulation and analytical/clinical testing. However, there are significant challenges in developing paper-based devices at the system level, which contain integrated paper-based power sources. Here, we report a microfabricated paper-based bacteria-powered battery that is capable of generating power from microbial metabolism. The battery on paper showed a very short start-up time relative to conventional microbial fuel cells (MFCs); paper substrates eliminated the time traditional MFCs required to accumulate and acclimate bacteria on the anode. Only four batteries connected in series provided desired values of current and potential to power an LED for more than 30 minutes. The battery featured (i) a low-cost paper-based proton exchange membrane directly patterned on commercially available parchment paper and (ii) paper reservoirs for holding the anolyte and the catholyte for an extended period of time. Based on this concept, we also demonstrate the use of paper-based test platforms for the rapid characterization of electricity-generating bacteria. This paper-based microbial screening tool does not require external pumps/tubings and represents the most rapid test platform (<50 min) compared with the time needed by using traditional screening tools (up to 103 days) and even recently proposed MEMS arrays (< 2 days).

  10. Applying high-throughput methods to develop a purification process for a highly glycosylated protein.

    PubMed

    Sanaie, Nooshafarin; Cecchini, Douglas; Pieracci, John

    2012-10-01

    Micro-scale chromatography formats are becoming more routinely used in purification process development because of their ability to rapidly screen large number of process conditions at a time with minimal material. Given the usual constraints that exist on development timelines and resources, these systems can provide a means to maximize process knowledge and process robustness compared to traditional packed column formats. In this work, a high-throughput, 96-well filter plate format was used in the development of the cation exchange and hydrophobic interaction chromatography steps of a purification process designed to alter the glycoform distribution of a small protein. The significant input parameters affecting process performance were rapidly identified for both steps and preliminary operating conditions were identified. These ranges were verified in a packed chromatography column in order to assess the ability of the 96-well plate to predict packed column performance. In both steps, the 96-well plate format consistently led to underestimated glycoform-enrichment levels and to overestimated product recovery rates compared to the column-based approach. These studies demonstrate that the plate format can be used as a screening tool to narrow the operating ranges prior to further optimization on packed chromatography columns. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Rapid Quantitative Detection of Brucella melitensis by a Label-Free Impedance Immunosensor Based on a Gold Nanoparticle-Modified Screen-Printed Carbon Electrode

    PubMed Central

    Wu, Haiyun; Zuo, Yueming; Cui, Chuanjin; Yang, Wei; Ma, Haili; Wang, Xiaowen

    2013-01-01

    A rapid and simple method for quantitative monitoring of Brucella melitensis using electrochemical impedance spectroscopy (EIS) is reported for the first time. The label-free immunosensors were fabricated by immobilizing Brucella melitensis antibody on the surface of gold nanoparticle-modified screen-printed carbon electrodes (GNP-SPCEs). Cyclic voltammetry (CV) and EIS were used to characterize the Brucella melitensis antigen interaction on the surface of GNP-SPCEs with antibody. A general electronic equivalent model of an electrochemical cell was introduced for interpretation of the impedance components of the system. The results showed that the change in electron-transfer resistance (Rct) was significantly different due to the binding of Brucella melitensis cells. A linear relationship between the Rct variation and logarithmic value of the cell concentration was found from 4 × 104 to 4 × 106 CFU/mL in pure culture. The label-free impedance biosensor was able to detect as low as 1 × 104 and 4 × 105 CFU/mL of Brucella melitensis in pure culture and milk samples, respectively, in less than 1.5 h. Moreover, a good selectivity versus Escherichia coli O157:H7 and Staphylococcus aureus cells was obtained for our developed immunosensor demonstrating its specificity towards only Brucella melitensis. PMID:23881126

  12. Investigation of Aerodynamic and Icing Characteristics of a Flush Alternate Inlet Induction System Air Scoop

    NASA Technical Reports Server (NTRS)

    Lewis, James P.

    1953-01-01

    An investigation has been made in the NACA Lewis icing research tunnel to determine the aerodynamic and icing characteristics of a full-scale induction-system air-scoop assembly incorporating a flush alternate inlet. The flush inlet was located immediately downstream of the offset ram inlet and included a 180 deg reversal and a 90 deg elbow in the ducting between inlet and carburetor top deck. The model also had a preheat-air inlet. The investigation was made over a range of mass-air- flow ratios of 0 to 0.8, angles of attack of 0 and 4 deg airspeeds of 150 to 270 miles per hour, air temperatures of 0 and 25 F various liquid-water contents, and droplet sizes. The ram inlet gave good pressure recovery in both clear air and icing but rapid blockage of the top-deck screen occurred during icing. The flush alternate inlet had poor pressure recovery in both clear air and icing. The greatest decreases in the alternate-inlet pressure recovery were obtained at icing conditions of low air temperature and high liquid-water content. No serious screen icing was observed with the alternate inlet. Pressure and temperature distributions on the carburetor top deck were determined using the preheat-air supply with the preheat- and alternate-inlet doors in various positions. No screen icing occurred when the preheat-air system was operated in combination with alternate-inlet air flow.

  13. High-Throughput Silencing Using the CRISPR-Cas9 System: A Review of the Benefits and Challenges.

    PubMed

    Wade, Mark

    2015-09-01

    The clustered regularly interspaced short palindromic repeats (CRISPR)/Cas system has been seized upon with a fervor enjoyed previously by small interfering RNA (siRNA) and short hairpin RNA (shRNA) technologies and has enormous potential for high-throughput functional genomics studies. The decision to use this approach must be balanced with respect to adoption of existing platforms versus awaiting the development of more "mature" next-generation systems. Here, experience from siRNA and shRNA screening plays an important role, as issues such as targeting efficiency, pooling strategies, and off-target effects with those technologies are already framing debates in the CRISPR field. CRISPR/Cas can be exploited not only to knockout genes but also to up- or down-regulate gene transcription-in some cases in a multiplex fashion. This provides a powerful tool for studying the interaction among multiple signaling cascades in the same genetic background. Furthermore, the documented success of CRISPR/Cas-mediated gene correction (or the corollary, introduction of disease-specific mutations) provides proof of concept for the rapid generation of isogenic cell lines for high-throughput screening. In this review, the advantages and limitations of CRISPR/Cas are discussed and current and future applications are highlighted. It is envisaged that complementarities between CRISPR, siRNA, and shRNA will ensure that all three technologies remain critical to the success of future functional genomics projects. © 2015 Society for Laboratory Automation and Screening.

  14. Rapid polymerase chain reaction screening of Helicobacter pylori chromosomal point mutations.

    PubMed

    Ge, Z; Taylor, D E

    1997-09-01

    Microdiversity (within individual genes) in the genomes of different Helicobacter pylori strains has been demonstrated to be more frequent than that seen in other prokaryotes. Point mutations in some genes, such as the vacA and 23S ribosomal RNA genes could result in the alteration of pathogenicity or antibiotic susceptibility of individual H. pylori strains. Development of a simple, rapid, and reliable screening method would be useful in the molecular characterization of genetic variation among different H. pylori strains. The copP gene from H. pylori UA802 was used as a model for developing a mutation screening method. Four point mutations were introduced into the copP gene by in vitro site-directed mutagenesis and were verified by DNA sequencing. The mutated copP gene replaced the wild-type locus by natural transformation and homologous recombination. The site-specific mutants were screened by polymerase chain reaction (PCR) using 3'-end mismatched primers. The origins of the PCR fragments were demonstrated by Southern hybridization with the copP-derived DNA probe. Three of these four mutations were characterized by PCR with the specific primers that contained the 3'-terminal nucleotide complementary only to the mutated nucleotide on both plasmid and chromosomal DNA templates. One mutation was able to be identified with the foregoing primer containing an additional wild-type nucleotide at its 3'-end. Point mutant screening with these specific primers offers 100% sensitivity in the aforementioned conditions. To achieve optimal screening, the concentration of magnesium and the annealing temperature have to be adjusted. The procedure reported in this study is a simple, economical, rapid, and efficient approach in the identification of site-specific mutations on both plasmids and chromosomal DNA. Although the method was developed by using a specified H. pylori gene, it can be extended easily to other genes of interest in H. pylori or other organisms.

  15. Optimization of information content in a mass spectrometry based flow-chemistry system by investigating different ionization approaches.

    PubMed

    Martha, Cornelius T; Hoogendoorn, Jan-Carel; Irth, Hubertus; Niessen, Wilfried M A

    2011-05-15

    Current development in catalyst discovery includes combinatorial synthesis methods for the rapid generation of compound libraries combined with high-throughput performance-screening methods to determine the associated activities. Of these novel methodologies, mass spectrometry (MS) based flow chemistry methods are especially attractive due to the ability to combine sensitive detection of the formed reaction product with identification of introduced catalyst complexes. Recently, such a mass spectrometry based continuous-flow reaction detection system was utilized to screen silver-adducted ferrocenyl bidentate catalyst complexes for activity in a multicomponent synthesis of a substituted 2-imidazoline. Here, we determine the merits of different ionization approaches by studying the combination of sensitive detection of product formation in the continuous-flow system with the ability to simultaneous characterize the introduced [ferrocenyl bidentate+Ag](+) catalyst complexes. To this end, we study the ionization characteristics of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), no-discharge APCI, dual ESI/APCI, and dual APCI/no-discharge APCI. Finally, we investigated the application potential of the different ionization approaches by the investigation of ferrocenyl bidentate catalyst complex responses in different solvents. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Alternate Protocol for Detecting Biological Contamination on Sensitive Hardware

    NASA Technical Reports Server (NTRS)

    Berlin, David; Lalime, Erin; Carosso, Nancy

    2015-01-01

    The purpose of this project is to develop a sterile water based rapid bioburden test. Contamination engineers use two tests to assess the level of biological contamination on hardware: the rapid five minute bioburden test, which is a molecular screening for Adenosine triphosphate (ATP), a molecule found in all cells on the hardware, and a slower colony growth test, which is used to give a more accurate representation of the amount of microbes on the hardware. However, the rapid bioburden test has limited application because it leaves a residue that can be detrimental to sensitive hardware. This can cause project delays while waiting for the results from the three day colony growth test. We address this problem by adapting the commercial germicide based ATP system to a sterile water based system. The test works by reacting ATP with D-Luciferin and Luciferase protein to yield light. The light is then detected by a luminometer that outputs a Relative Light Unit (RLU) amount depending on how much ATP is present. To analyze the effectiveness of the new test, we developed a correlation between amounts of ATP and the RLU produced using the germicide based system. From these experiments, we've generated a consistent relationship between the two in the form of a power curve. From there, we developed a correlation curve between the amount of colonies and the RLU they produced. Initial tests of the new protocol have shown that the water based system isn't as sensitive as the germicide based test.

  17. The clinician in the driver's seat: part 2 - intelligent uses of space in a drag/drop user-composable electronic health record.

    PubMed

    Senathirajah, Yalini; Kaufman, David; Bakken, Suzanne

    2014-12-01

    User-composable approaches provide clinicians with the control to design and assemble information elements on screen via drag/drop. They hold considerable promise for enhancing the electronic-health-records (EHRs) user experience. We previously described this novel approach to EHR design and our illustrative system, MedWISE. The purpose of this paper is to describe clinician users' intelligent uses of space during completion of real patient case studies in a laboratory setting using MedWISE. Thirteen clinicians at a quaternary academic medical center used the system to review four real patient cases. We analyzed clinician utterances, behaviors, screen layouts (i.e., interface designs), and their perceptions associated with completing patient case studies. Clinicians effectively used the system to review all cases. Two coding schemata pertaining to human-computer interaction and diagnostic reasoning were used to analyze the data. Users adopted three main interaction strategies: rapidly gathering items on screen and reviewing ('opportunistic selection' approach); creating highly structured screens ('structured' approach); and interacting with small groups of items in sequence as their case review progressed ('dynamic stage' approach). They also used spatial arrangement in ways predicted by theory and research on workplace spatial arrangement. This includes assignment of screen regions for particular purposes (24% of spatial codes), juxtaposition to facilitate calculation or other cognitive tasks ('epistemic action'), and grouping elements with common meanings or relevance to the diagnostic facets of the case (20.3%). A left-to-right progression of orienting materials, data, and action items or reflection space was a commonly observed pattern. Widget selection was based on user assessment of what information was useful or relevant. We developed and tested an illustrative system that gives clinicians greater control of the EHR, and demonstrated its feasibility for case review by typical clinicians. Producing the simplifying inventions, such as user-composable platforms that shift control to the user, may serve to promote productive EHR use and enhance its value as an instrument of patient care. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. The Clinician in the Driver’s Seat: Part 2 – Intelligent Uses of Space in a Drag/Drop User-Composable Electronic Health Record

    PubMed Central

    Senathirajah, Yalini; Kaufman, David; Bakken, Suzanne

    2018-01-01

    User-composable approaches provide clinicians with the control to design and assemble information elements on screen via drag/drop. They hold considerable promise for enhancing the electronic-health-records (EHRs) user experience. We previously described this novel approach to EHR design and our illustrative system, MedWISE. The purpose of this paper is to describe clinician users’ intelligent uses of space during completion of real patient case studies in a laboratory setting using MedWISE. Thirteen clinicians at a quaternary academic medical center used the system to review four real patient cases. We analyzed clinician utterances, behaviors, screen layouts (i.e., interface designs), and their perceptions associated with completing patient case studies. Clinicians effectively used the system to review all cases. Two coding schemata pertaining to human-computer interaction and diagnostic reasoning were used to analyze the data. Users adopted three main interaction strategies: rapidly gathering items on screen and reviewing (‘opportunistic selection’ approach); creating highly structured screens (‘structured’ approach); and interacting with small groups of items in sequence as their case review progressed (‘dynamic stage’ approach). They also used spatial arrangement in ways predicted by theory and research on workplace spatial arrangement. This includes assignment of screen regions for particular purposes (24% of spatial codes), juxtaposition to facilitate calculation or other cognitive tasks (‘epistemic action’), and grouping elements with common meanings or relevance to the diagnostic facets of the case (20.3%). A left-to-right progression of orienting materials, data, and action items or reflection space was a commonly observed pattern. Widget selection was based on user assessment of what information was useful or relevant. We developed and tested an illustrative system that gives clinicians greater control of the EHR, and demonstrated its feasibility for case review by typical clinicians. Producing the simplifying inventions, such as user-composable platforms that shift control to the user, may serve to promote productive EHR use and enhance its value as an instrument of patient care. PMID:25445921

  19. Magnifying Smartphone Screen Using Google Glass for Low-Vision Users.

    PubMed

    Pundlik, Shrinivas; HuaQi Yi; Rui Liu; Peli, Eli; Gang Luo

    2017-01-01

    Magnification is a key accessibility feature used by low-vision smartphone users. However, small screen size can lead to loss of context and make interaction with magnified displays challenging. We hypothesize that controlling the viewport with head motion can be natural and help in gaining access to magnified displays. We implement this idea using a Google Glass that displays the magnified smartphone screenshots received in real time via Bluetooth. Instead of navigating with touch gestures on the magnified smartphone display, the users can view different screen locations by rotating their head, and remotely interacting with the smartphone. It is equivalent to looking at a large virtual image through a head contingent viewing port, in this case, the Glass display with ~ 15 ° field of view. The system can transfer seven screenshots per second at 8 × magnification, sufficient for tasks where the display content does not change rapidly. A pilot evaluation of this approach was conducted with eight normally sighted and four visually impaired subjects performing assigned tasks using calculator and music player apps. Results showed that performance in the calculation task was faster with the Glass than with the phone's built-in screen zoom. We conclude that head contingent scanning control can be beneficial in navigating magnified small smartphone displays, at least for tasks involving familiar content layout.

  20. Rapid determination of trace nitrophenolic organics in water by combining solid-phase extraction with surface-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Chen, Y C; Shiea, J; Sunner, J

    2000-01-01

    A rapid technique for the screening of trace compounds in water by combining solid-phase extraction (SPE) with activated carbon surface-assisted laser desorption/ionization (SALDI) time-of-flight mass spectrometry is demonstrated. Activated carbon is used both as the sorbent in SPE and as the solid in the SALDI matrix system. This eliminates the need for an SPE elution process. After the analytes have been adsorbed on the surfaces of the activated carbon during SPE extraction, the activated carbon is directly mixed with the SALDI liquid and mass spectrometric analysis is performed. Trace phenolic compounds in water were used to demonstrate the effectiveness of the method. The detection limit for these compounds is in the ppb to ppt range. Copyright 2000 John Wiley & Sons, Ltd.

Top