Sample records for rate testing ssrt

  1. An Investigation into Stress Corrosion Cracking of Dissimilar Metal Welds with 304L Stainless Steel and Alloy 82 in High Temperature Pure Water

    NASA Astrophysics Data System (ADS)

    Yeh, Tsung-Kuang; Huang, Guan-Ru; Tsai, Chuen-Horng; Wang, Mei-Ya

    For a better understanding toward stress corrosion cracking (SCC) in dissimilar metal welds with 304L stainless steel and Alloy 82, the SCC growth behavior in the transition regions of weld joints was investigated via slow strain rate tensile (SSRT) tests in 280 oC pure water with a dissolve oxygen level of 300 ppb. Prior to the SSRT tests, samples with dissimilar metal welds were prepared and underwent various pretreatments, including post-weld heat treatment (PWHT), shot peening, solution annealing, and mechanical grinding. In addition to the SSRT tests, measurements of degree of sensitization and micro-hardness on the transition regions of the metal welds were also conducted. According to the test results, the samples having undergone PWHTs exhibited relatively high degrees of sensitization. Distinct decreases in hardness were observed in the heat-affected zones of the base metals in all samples. Furthermore, the fracture planes of all samples after the SSRT tests were located at the stainless steel sides and were in parallel with the fusion lines. Among the treating conditions investigated in this study, a PWHT would pose a detrimental effect on the samples in the aspects of mechanical property and degree of SCC. Solution annealing would lead to the greatest improvement in ductility and SCC retardation, and shot peening would provide the treated samples with a positive improvement in ductility and corrosion retardation, but not to a great extent.

  2. Stress Corrosion Cracking of an Austenitic Stainless Steel in Nitrite-Containing Chloride Solutions

    PubMed Central

    Singh Raman, R. K.; Siew, Wai Hoong

    2014-01-01

    This article describes the susceptibility of 316L stainless steel to stress corrosion cracking (SCC) in a nitrite-containing chloride solution. Slow strain rate testing (SSRT) in 30 wt. % MgCl2 solution established SCC susceptibility, as evidenced by post-SSRT fractography. Addition of nitrite to the chloride solution, which is reported to have inhibitive influence on corrosion of stainless steels, was found to increase SCC susceptibility. The susceptibility was also found to increase with nitrite concentration. This behaviour is explained on the basis of the passivation and pitting characteristics of 316L steel in chloride solution. PMID:28788276

  3. Stress Corrosion Cracking of Pipeline Steels in Fuel Grade Ethanol and Blends - Study to Evaluate Alternate Standard Tests and Phenomenological Understanding of SCC

    DOT National Transportation Integrated Search

    2011-10-30

    Main aim of this project was to evaluate alternate standard test methods for stress corrosion cracking (SCC) and compare them with the results from slow strain rate test (SSRT) results under equivalent environmental conditions. Other important aim of...

  4. Evaluation of high-strength Cu-Ni-Mn-Al bolting used in oil and gas service

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, O.; Joosten, M.W.; Murali, J.

    1996-08-01

    High strength bolts, nuts, studs and screws manufactured from a precipitation hardening Cu-Ni-Mn-Al alloy have experienced several failures in recent years in oilfield installations with varying degrees of severity and consequence. Such failures have been broadly attributed to Stress Corrosion Cracking (SCC) and Liquid Metal Embrittlement (LME) phenomena. A detailed test program using the Slow Strain Rate Testing (SSRT) method has been conducted to identify the various parameters which could contribute to SCC. Results indicate that the Cu-Ni-Mn-Al alloy is susceptible to SCC in a variety of environments commonly found in oilfield equipment manufacturing and field installations such as amine-containingmore » additives, sulfides and even natural seawater at elevated temperatures. SSRT testing indicated, however, that, in seawater environments, low service temperatures and cathodic protection did not adversely affect the alloy`s performance. Discussion of test program results and qualitative correlations with field failures are presented.« less

  5. Influence of Localized Plasticity on IASCC Sensitivity of Austenitic Stainless Steels under PWR Primary Water

    NASA Astrophysics Data System (ADS)

    Cissé, Sarata; Tanguy, Benoit; Laffont, Lydia; Lafont, Marie-Christine; Guerre, Catherine; Andrieu, Eric

    The sensibility of precipitation-strengthened A286 austenitic stainless steel to Stress Corrosion Cracking (SCC) is studied by means of Slow Strain Rate Tests (SSRT). First, alloy cold working by Low Cycle Fatigue (LCF) is investigated. Fatigue tests under plastic strain control are performed at different strain levels (Δ ɛp/2=0.2%, 0.5% and 0.8%) in order to establish correlation between stress softening and deformation microstructure resulting from LCF tests. Deformed microstructures have been identified through TEM investigations. Three states of cyclic behaviour for precipitation-strengthened A286 have been identified: hardening, cyclic softening and finally saturation of softening. It is shown that the A286 alloy cyclic softening is due to microstructural features such as defects — free deformation bands resulting from dislocations motion along family plans <111>, that swept defects or γ' precipitates and lead to deformation localization. In order to quantify effects of plastic localized deformation on intergranular stress corrosion cracking (IGSCC) of the A286 alloy in PWR primary water, slow strain rate tests are conducted. For each cycling conditions, two specimens at a similar stress level are tested: the first containing free precipitate deformation bands, the other not significant of a localized deformation state. SSRT tests are still in progress.

  6. Characteristics of lead induced stress corrosion cracking of alloy 690 in high temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, K.K.; Lim, J.K.; Watanabe, Yutaka

    1996-10-01

    Slow strain rate tests (SSRT) were conducted on alloy 690 in various lead chloride solutions and metal lead added to 100 ppm chloride solution at 288 C. The corrosion potential (rest potential) for the alloy was measured with SSRT tests. The cracking was observed by metallographic examination and electron probe micro analyzer. Also, the corrosion behavior of the alloy was evaluated by anodic polarized measurement at 30 C. Resulting from the tests, cracking was characterized by cracking behavior, crack length and crack growth rate, and lead effects on cracking. The cracking was mainly intergranular in mode, approximately from 60 ummore » to 450 um in crack length, and approximately 10{sup {minus}6} to 10{sup {minus}7} mmS-1 in crack velocity. The cracking was evaluated through the variation the corrosion potential in potential-time and lead behavior during SSRTs. The lead effect in corrosion was evaluated through active to passive transition behavior in anodic polarized curves. The corrosion reactions in the cracking region were confirmed by electron probe microanalysis. Alloy 690 is used for steam generation tubes in pressurized water reactors.« less

  7. Investigation of Hydrogen Embrittlement Susceptibility of X80 Weld Joints by Thermal Simulation

    NASA Astrophysics Data System (ADS)

    Peng, Huangtao; An, Teng; Zheng, Shuqi; Luo, Bingwei; Wang, Siyu; Zhang, Shuai

    2018-05-01

    The objective of this study was to investigate the hydrogen embrittlement (HE) susceptibility and influence mechanism of X80 weld joints. Slow strain rate testing (SSRT) under in situ H-charging, combined with microstructure and fracture analysis, was performed on the base metal (BM), weld metal (WM), thermally simulated fine-grained heat-affected zone (FGHAZ) and coarse-grained heat-affected zone (CGHAZ). Results showed that the WM and simulated HAZ had a greater degree of high local strain distribution than the BM; compared to the CGHAZ, the FGHAZ had lower microhardness and more uniformly distributed stress. SSRT results showed that the weld joint was highly sensitive to HE; the HE index decreased in the following sequence: FGHAZ, WM, CGHAZ and BM. The effect of the microstructure on HE was mainly reflected in microstructure, local stress distribution and microhardness.

  8. Lead induced stress corrosion cracking of Alloy 690 in high temperature water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, K.K.; Lim, J.K.; Moriya, Shinichi

    1995-12-31

    Recent investigations of cracked steam generator tubes at nuclear power plants concluded that lead significantly contributed to cracking the Alloy 600 materials. In order to investigate the stress corrosion cracking (SCC) behavior of Alloy 690, slow strain rate tests (SSRT) and anodic polarization measurements were performed. The SSRTs were conducted in a lead-chloride solution (PbCl{sub 2}) and in a chloride but lead free solution (NaCl) at pH of 3 and 4.5 at 288 C. The anodic polarization measurements were carried out at 30 C using the same solutions as in SSRT. The SSRT results showed that Alloy 690 was susceptiblemore » to SCC in both solutions. In the lead chloride solution, cracking had slight dependence on lead concentration and pH. Cracking tend to increase with a higher lead concentration and a lower pH and was mainly intergranular and was to be a few tens to hundreds micrometers in length. In the chloride only solution, cracking was similar to the lead induced SCC. The results of anodic polarization measurement and electron probe micro analysis (EPMA) helped to understand lead induced SCC. Lead was a stronger active corrosive element but had a minor affect on cracking susceptibility of the alloy. While, chloride was quite different from lead effect to SCC. A possible mechanism of lead induced SCC of Alloy 690 was also discussed based on the test results.« less

  9. Magnesium alloys as body implants: fracture mechanism under dynamic and static loadings in a physiological environment.

    PubMed

    Choudhary, Lokesh; Raman, R K Singh

    2012-02-01

    It is essential that a metallic implant material possesses adequate resistance to cracking/fracture under the synergistic action of a corrosive physiological environment and mechanical loading (i.e. stress corrosion cracking (SCC)), before the implant can be put to actual use. This paper presents a critique of the fundamental issues with an assessment of SCC of a rapidly corroding material such as magnesium alloys, and describes an investigation into the mechanism of SCC of a magnesium alloy in a physiological environment. The SCC susceptibility of the alloy in a simulated human body fluid was established by slow strain rate tensile (SSRT) testing using smooth specimens under different electrochemical conditions for understanding the mechanism of SCC. However, to assess the life of the implant devices that often possess fine micro-cracks, SCC susceptibility of notched specimens was investigated by circumferential notch tensile (CNT) testing. CNT tests also produced important design data, i.e. threshold stress intensity for SCC (KISCC) and SCC crack growth rate. Fractographic features of SCC were examined using scanning electron microscopy. The SSRT and CNT results, together with fractographic evidence, confirmed the SCC susceptibility of both smooth and notched specimens of a magnesium alloy in the physiological environment. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Single Stage Rocket Technology (SSRT) DC-X Test Program Environmental Assessment

    DTIC Science & Technology

    1992-06-01

    23). 2.2.1.5 Cultural Resources Section 106 of the National Historic Preservation Act (NHPA) requires Federal agencies to consider the affects of...were coordinated with the New Mexico State Historic Preservation Office. June 1992 UncLassified 2-7 EaWronmemW~ AWsnevssln SSRT Habitat lor White... Preservation (ACHP), and the New Mexico State Historic Preservation Office. Compliance with Section 106 of the National Historic Preservation Act for the

  11. Stress corrosion study of PH13-8Mo stainless steel using the Slow Strain Rate Technique

    NASA Technical Reports Server (NTRS)

    Torres, Pablo D.

    1989-01-01

    The need for a fast and reliable method to study stress corrosion in metals has caused increased interest in the Slow Strain Rate Technique (SSRT) during the last few decades. PH13-8MoH950 and H1000 round tensile specimens were studied by this method. Percent reduction-in-area, time-to-failure, elongation at fracture, and fracture energy were used to express the loss in ductility, which has been used to indicate susceptibility to stress corrosion cracking (SCC). Results from a 3.5 percent salt solution (corrosive medium) were compared to those in air (inert medium). A tendency to early failure was found when testing in the vicinity of 1.0 x 10(-6) mm/mm/sec in the 3.5 percent salt solution. PH13-8Mo H1000 was found to be less likely to suffer SCC than PH13-8Mo H950. This program showed that the SSRT is promising for the SCC characterization of metals and results can be obtained in much shorter times (18 hr for PH steels) than those required using conventional techniques.

  12. Effect of temperature and dissolved oxygen on stress corrosion cracking behavior of P92 ferritic-martensitic steel in supercritical water environment

    NASA Astrophysics Data System (ADS)

    Zhang, Z.; Hu, Z. F.; Zhang, L. F.; Chen, K.; Singh, P. M.

    2018-01-01

    The effect of temperature and dissolved oxygen (DO) on stress corrosion cracking (SCC) of P92 martensitic steel in supercritical water (SCW) was investigated using slow strain rate test (SSRT) and fractography analysis. The SSRT was carried out at temperatures of 400, 500, 600 °C in deaerated supercritical water and at DO contents of 0, 200, 500 ppb at the temperature of 600 °C, respectively. The results of SSRT show that the decrease of ductility at the temperature of 400 °C may be related to the dynamic strain aging (DSA) of P92 steel. The degradation of the mechanical properties in SCW is the joint effect of temperature and SCC. Compared with the effect of temperature, DO in SCW has no significant effect on the SCC susceptibility of P92 steel. The observation of oxide layer shows that large numbers of pores are nucleated in the oxide layer, which is related to vacancy accumulation and hydrogen generated in the oxide layer. Under the combined action of the growth stress and tensile stress, micro cracks, nucleated from the pores in the oxide layer, are easily propagated intergranularly outward to the surface of specimen, and fewer cracks can extend inward along the intrinsic pores to the inner oxide/metal interface, which is the reason for the exfoliation of oxide films.

  13. Hydrogen Embrittlement of Automotive Advanced High-Strength Steels

    NASA Astrophysics Data System (ADS)

    Lovicu, Gianfranco; Bottazzi, Mauro; D'Aiuto, Fabio; De Sanctis, Massimo; Dimatteo, Antonella; Santus, Ciro; Valentini, Renzo

    2012-11-01

    Advanced high-strength steels (AHSS) have a better combination between strength and ductility than conventional HSS, and higher crash resistances are obtained in concomitance with weight reduction of car structural components. These steels have been developed in the last few decades, and their use is rapidly increasing. Notwithstanding, some of their important features have to be still understood and studied in order to completely characterize their service behavior. In particular, the high mechanical resistance of AHSS makes hydrogen-related problems a great concern for this steel grade. This article investigates the hydrogen embrittlement (HE) of four AHSS steels. The behavior of one transformation induced plasticity (TRIP), two martensitic with different strength levels, and one hot-stamping steels has been studied using slow strain rate tensile (SSRT) tests on electrochemically hydrogenated notched samples. The embrittlement susceptibility of these AHSS steels has been correlated mainly to their strength level and to their microstructural features. Finally, the hydrogen critical concentrations for HE, established by SSRT tests, have been compared to hydrogen contents absorbed during the painting process of a body in white (BIW) structure, experimentally determined during a real cycle in an industrial plant.

  14. Gender differences in the association between stop-signal reaction times, body mass indices and/or spontaneous food intake in pre-school children: an early model of compromised inhibitory control and obesity.

    PubMed

    Levitan, R D; Rivera, J; Silveira, P P; Steiner, M; Gaudreau, H; Hamilton, J; Kennedy, J L; Davis, C; Dube, L; Fellows, L; Wazana, A; Matthews, S; Meaney, M J

    2015-04-01

    Poor inhibitory control is associated with overeating and/or obesity in school-age children, adolescents and adults. The current study examined whether an objective and reliable marker of response inhibition, the stop-signal reaction time (SSRT), is associated with body mass index (BMI) z-scores and/or food intake during a snack test in pre-school children. The current sample consisted of 193 pre-school children taking part in a longitudinal study of early brain development (Maternal Adversity, Vulnerability and Neurodevelopment (the MAVAN project)). Linear mixed-effect models were used to examine whether the SSRT measured at age 48 months associated with BMI z-scores and/or dietary intake during a laboratory-based snack test. After controlling for significant covariates including maternal BMI, there was a significant gender by SSRT interaction effect in predicting 48-month BMI z-scores. Post-hoc analysis revealed an association between longer SSRTs (poor response inhibition) and higher BMIs in girls but not boys. Across both girls and boys, longer SSRTs were associated with greater intake of carbohydrates and sugars during the snack test. The association between SSRT scores and BMI z-scores in girls was not statistically mediated by carbohydrate or sugar intake. At 48 months of age, slower response inhibition on the Stop-Signal Task associates with higher BMI z-scores in girls, and with higher intake of carbohydrates and sugars during a snack test across both genders. Ongoing follow-up of these children will help clarify the implications of these associations for longer term macronutrient intake, eating-related pathology and/or pathological weight gain over time.

  15. Stopping at the sight of food - How gender and obesity impact on response inhibition.

    PubMed

    Mühlberg, Christoph; Mathar, David; Villringer, Arno; Horstmann, Annette; Neumann, Jane

    2016-12-01

    Recent research indicates that reduced inhibitory control is associated with higher body mass index (BMI), higher food craving and increased food intake. However, experimental evidence for the relationship between response inhibition and weight status is inconsistent and to date has been investigated predominantly in women. In the current study, 56 participants (26 obese, 30 lean; 27 female, 29 male) performed a Food Picture Rating Task followed by a Stop Signal Task where pictures of palatable high or low caloric food or non-food items were presented prior to the Go signal. We further assessed participants' self-reported eating behavior and trait impulsivity as potential factors influencing response inhibition, in particular within the food context. Independent of BMI, women showed significantly higher liking for low caloric food items than men. This was accompanied by shorter Stop Signal Reaction Times (SSRT) after high compared to low caloric food pictures for women, and shorter SSRT in women compared to men for high caloric food. No influence of gender on SSRT was observable outside of the food context. While SSRTs did not differ between obese and lean participants across the three picture categories, we found a moderating effect of trait impulsivity on the relationship between BMI and SSRT, specifically in the high caloric food context. Higher BMI was predictive of longer SSRT only for participants with low to normal trait impulsivity, pointing at a complex interplay between response inhibition, general impulsivity and weight status. Our results support the notion that individuals with obesity do not suffer from diminished response inhibition capacity per se. Rather, the ability to withhold a response depends on context and social norms, and strongly interacts with factors like gender and trait impulsivity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Objectively-measured impulsivity and attention-deficit/hyperactivity disorder (ADHD): testing competing predictions from the working memory and behavioral inhibition models of ADHD.

    PubMed

    Raiker, Joseph S; Rapport, Mark D; Kofler, Michael J; Sarver, Dustin E

    2012-07-01

    Impulsivity is a hallmark of two of the three DSM-IV ADHD subtypes and is associated with myriad adverse outcomes. Limited research, however, is available concerning the mechanisms and processes that contribute to impulsive responding by children with ADHD. The current study tested predictions from two competing models of ADHD-working memory (WM) and behavioral inhibition (BI)-to examine the extent to which ADHD-related impulsive responding was attributable to model-specific mechanisms and processes. Children with ADHD (n = 21) and typically developing children (n = 20) completed laboratory tasks that provided WM (domain-general central executive [CE], phonological/visuospatial storage/rehearsal) and BI indices (stop-signal reaction time [SSRT], stop-signal delay, mean reaction time). These indices were examined as potential mediators of ADHD-related impulsive responding on two objective and diverse laboratory tasks used commonly to assess impulsive responding (CPT: continuous performance test; VMTS: visual match-to-sample). Bias-corrected, bootstrapped mediation analyses revealed that CE processes significantly attenuated between-group impulsivity differences, such that the initial large-magnitude impulsivity differences were no longer significant on either task after accounting for ADHD-related CE deficits. In contrast, SSRT partially mediated ADHD-related impulsive responding on the CPT but not VMTS. This partial attenuation was no longer significant after accounting for shared variance between CE and SSRT; CE continued to attenuate the ADHD-impulsivity relationship after accounting for SSRT. These findings add to the growing literature implicating CE deficits in core ADHD behavioral and functional impairments, and suggest that cognitive interventions targeting CE rather than storage/rehearsal or BI processes may hold greater promise for alleviating ADHD-related impairments.

  17. Stress and alcohol cues exert conjoint effects on go and stop signal responding in male problem drinkers.

    PubMed

    Zack, Martin; Woodford, Tracy M; Tremblay, Anne M; Steinberg, Lindsay; Zawertailo, Laurie A; Busto, Usoa E

    2011-01-01

    Stress, cues, and pharmacological priming are linked with relapse to addictive behavior. Increased salience and decreased inhibitory control are thought to mediate the effects of relapse-related stimuli. However, the functional relationship between these two processes is unclear. To address this issue, a modified Stop Signal Task was employed, which used Alcohol, Neutral, and Non-Words as Go stimuli, and lexical decision as the Go response. Subjects were 38 male problem drinkers (mean Alcohol Dependence Scale (ADS) score: 18.0). Uncontrollable noise (∼ 10 min at 110 dB) was the stressor; nonalcoholic placebo beer (P-Beer) was the cue manipulation, and alcohol (0.7 g/kg), the pharmacological prime. Half the sample received alcohol, and half P-Beer. Stress and beverage (test drink vs soft drink) were manipulated within subjects on two sessions, with half the sample receiving active manipulations together and half receiving them separately. Go response time (RT) and Stop Signal RT (SSRT) were slower to Alcohol than Neutral words. Stress augmented this bias. Alcohol and P-Beer impaired overall SSRT. Stress impaired neither overall SSRT nor Go RT. SSRT to Neutral words and Non-Words correlated inversely with Go RT to Alcohol and Neutral words, and Non-Words. ADS correlated directly with SSRT to Alcohol words. A resource allocation account was proposed, whereby diversion of limited resources to salient cues effectively yoked otherwise independent Go and Stop processes. Disturbances of prefrontal norepinephrine and dopamine were cited as possibly accounting for these effects. Treatments that optimize prefrontal catecholamine transmission may deter relapse by reducing disinhibitory effects of salient eliciting stimuli.

  18. Stress and Alcohol Cues Exert Conjoint Effects on Go and Stop Signal Responding in Male Problem Drinkers

    PubMed Central

    Zack, Martin; Woodford, Tracy M; Tremblay, Anne M; Steinberg, Lindsay; Zawertailo, Laurie A; Busto, Usoa E

    2011-01-01

    Stress, cues, and pharmacological priming are linked with relapse to addictive behavior. Increased salience and decreased inhibitory control are thought to mediate the effects of relapse-related stimuli. However, the functional relationship between these two processes is unclear. To address this issue, a modified Stop Signal Task was employed, which used Alcohol, Neutral, and Non-Words as Go stimuli, and lexical decision as the Go response. Subjects were 38 male problem drinkers (mean Alcohol Dependence Scale (ADS) score: 18.0). Uncontrollable noise (∼10 min at 110 dB) was the stressor; nonalcoholic placebo beer (P-Beer) was the cue manipulation, and alcohol (0.7 g/kg), the pharmacological prime. Half the sample received alcohol, and half P-Beer. Stress and beverage (test drink vs soft drink) were manipulated within subjects on two sessions, with half the sample receiving active manipulations together and half receiving them separately. Go response time (RT) and Stop Signal RT (SSRT) were slower to Alcohol than Neutral words. Stress augmented this bias. Alcohol and P-Beer impaired overall SSRT. Stress impaired neither overall SSRT nor Go RT. SSRT to Neutral words and Non-Words correlated inversely with Go RT to Alcohol and Neutral words, and Non-Words. ADS correlated directly with SSRT to Alcohol words. A resource allocation account was proposed, whereby diversion of limited resources to salient cues effectively yoked otherwise independent Go and Stop processes. Disturbances of prefrontal norepinephrine and dopamine were cited as possibly accounting for these effects. Treatments that optimize prefrontal catecholamine transmission may deter relapse by reducing disinhibitory effects of salient eliciting stimuli. PMID:20927046

  19. In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid.

    PubMed

    Kannan, M Bobby; Raman, R K Singh

    2008-05-01

    The successful applications of magnesium-based alloys as degradable orthopaedic implants are mainly inhibited due to their high degradation rates in physiological environment and consequent loss in the mechanical integrity. This study examines the degradation behaviour and the mechanical integrity of calcium-containing magnesium alloys using electrochemical techniques and slow strain rate test (SSRT) method, respectively, in modified-simulated body fluid (m-SBF). Potentiodynamic polarisation and electrochemical impedance spectroscopy (EIS) results showed that calcium addition enhances the general and pitting corrosion resistances of magnesium alloys significantly. The corrosion current was significantly lower in AZ91Ca alloy than that in AZ91 alloy. Furthermore, AZ91Ca alloy exhibited a five-fold increase in the surface film resistance than AZ91 alloy. The SSRT results showed that the ultimate tensile strength and elongation to fracture of AZ91Ca alloy in m-SBF decreased only marginally (approximately 15% and 20%, respectively) in comparison with these properties in air. The fracture morphologies of the failed samples are discussed in the paper. The in vitro study suggests that calcium-containing magnesium alloys to be a promising candidate for their applications in degradable orthopaedic implants, and it is worthwhile to further investigate the in vivo corrosion behaviour of these alloys.

  20. Measurement and Reliability of Response Inhibition

    PubMed Central

    Congdon, Eliza; Mumford, Jeanette A.; Cohen, Jessica R.; Galvan, Adriana; Canli, Turhan; Poldrack, Russell A.

    2012-01-01

    Response inhibition plays a critical role in adaptive functioning and can be assessed with the Stop-signal task, which requires participants to suppress prepotent motor responses. Evidence suggests that this ability to inhibit a prepotent motor response (reflected as Stop-signal reaction time (SSRT)) is a quantitative and heritable measure of interindividual variation in brain function. Although attention has been given to the optimal method of SSRT estimation, and initial evidence exists in support of its reliability, there is still variability in how Stop-signal task data are treated across samples. In order to examine this issue, we pooled data across three separate studies and examined the influence of multiple SSRT calculation methods and outlier calling on reliability (using Intra-class correlation). Our results suggest that an approach which uses the average of all available sessions, all trials of each session, and excludes outliers based on predetermined lenient criteria yields reliable SSRT estimates, while not excluding too many participants. Our findings further support the reliability of SSRT, which is commonly used as an index of inhibitory control, and provide support for its continued use as a neurocognitive phenotype. PMID:22363308

  1. Strain rate effects in stress corrosion cracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parkins, R.N.

    Slow strain rate testing (SSRT) was initially developed as a rapid, ad hoc laboratory method for assessing the propensity for metals an environments to promote stress corrosion cracking. It is now clear, however, that there are good theoretical reasons why strain rate, as opposed to stress per se, will often be the controlling parameter in determining whether or not cracks are nucleated and, if so, are propagated. The synergistic effects of the time dependence of corrosion-related reactions and microplastic strain provide the basis for mechanistic understanding of stress corrosion cracking in high-pressure pipelines and other structures. However, while this maymore » be readily comprehended in the context of laboratory slow strain tests, its extension to service situations may be less apparent. Laboratory work involving realistic stressing conditions, including low-frequency cyclic loading, shows that strain or creep rates give good correlation with thresholds for cracking and with crack growth kinetics.« less

  2. Variations in response control within at-risk gamblers and non-gambling controls explained by GABAergic inhibition in the motor cortex.

    PubMed

    Chowdhury, Nahian S; Livesey, Evan J; Blaszczynski, Alex; Harris, Justin A

    2018-06-01

    Paired-pulse Transcranial Magnetic Stimulation (TMS) is used to study inhibitory and excitatory mechanisms in the motor cortex through the measurement of short-interval intracortical inhibition (SICI), indicative of GABAergic activity, and intracortical facilitation (ICF), indicative of glutamatergic activity. In the present study, TMS was delivered to the left motor cortex of 40 participants while we measured SICI and ICF at rest. We were interested in whether variation between individuals in these modulatory mechanisms is related to inhibitory control over responding measured as stop signal reaction time (SSRT). Within the same group of participants, we investigated whether SICI, ICF, SSRT, and self-reported impulsivity, are impaired in participants identified as At-Risk gamblers (n = 20) compared to non-gambling controls (n = 20). We found a significant negative correlation between SICI strength and SSRT, but no correlation between ICF strength and SSRT after controlling for the correlation between SICI and SSRT. Thus, poor inhibitory control of responding was associated with weak GABAergic activity. When taking into account the effects of substance/alcohol use and attention-deficit hyperactivity disorder (ADHD) symptom severity, At-Risk gamblers showed elevated self-reported impulsivity, but did not differ from controls on SSRT or SICI/ICF. Our study is the first to show that individual differences in motor cortex inhibition can predict stopping performance, and the first to investigate paired-pulse TMS parameters (together with other impulse control measures) in a gambling population. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Space Storable Rocket Technology (SSRT) basic program

    NASA Technical Reports Server (NTRS)

    Chazen, M. L.; Mueller, T.; Casillas, A. R.; Huang, D.

    1992-01-01

    The Space Storable Rocket Technology Program (SSRT) was conducted to establish a technology for a new class of high performance and long life bipropellant engines using space storable propellants. The results are described. Task 1 evaluated several characteristics for a number of fuels to determine the best space storable fuel for use with LO2. The results indicated that LO2-N2H4 is the best propellant combination and provides the maximum mission/system capability maximum payload into GEO of satellites. Task 2 developed two models, performance and thermal. The performance model indicated the performance goal of specific impulse greater than or = 340 seconds (sigma = 204) could be achieved. The thermal model was developed and anchored to hot fire test data. Task 3 consisted of design, fabrication, and testing of a 200 lbf thrust test engine operating at a chamber pressure of 200 psia using LO2-N2H4. A total of 76 hot fire tests were conducted demonstrating performance greater than 340 (sigma = 204) which is a 25 second specific impulse improvement over the existing highest performance flight apogee type engines.

  4. Cracking behavior and microstructure of austenitic stainless steels and alloy 690 irradiated in BOR-60 reactor, phase I.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Y.; Chopra, O. K.; Soppet, W. K.

    2010-02-16

    Cracking behavior of stainless steels specimens irradiated in the BOR-60 at about 320 C is studied. The primary objective of this research is to improve the mechanistic understanding of irradiation-assisted stress corrosion cracking (IASCC) of core internal components under conditions relevant to pressurized water reactors. The current report covers several baseline tests in air, a comparison study in high-dissolved-oxygen environment, and TEM characterization of irradiation defect structure. Slow strain rate tensile (SSRT) tests were conducted in air and in high-dissolved-oxygen (DO) water with selected 5- and 10-dpa specimens. The results in high-DO water were compared with those from earlier testsmore » with identical materials irradiated in the Halden reactor to a similar dose. The SSRT tests produced similar results among different materials irradiated in the Halden and BOR-60 reactors. However, the post-irradiation strength for the BOR-60 specimens was consistently lower than that of the corresponding Halden specimens. The elongation of the BOR-60 specimens was also greater than that of their Halden specimens. Intergranular cracking in high-DO water was consistent for most of the tested materials in the Halden and BOR-60 irradiations. Nonetheless, the BOR-60 irradiation was somewhat less effective in stimulating IG fracture among the tested materials. Microstructural characterization was also carried out using transmission electron microscopy on selected BOR-60 specimens irradiated to {approx}25 dpa. No voids were observed in irradiated austenitic stainless steels and cast stainless steels, while a few voids were found in base and grain-boundary-engineered Alloy 690. All the irradiated microstructures were dominated by a high density of Frank loops, which varied in mean size and density for different alloys.« less

  5. Corrosion and stress corrosion cracking of ferritic/martensitic steel in super critical pressurized water

    NASA Astrophysics Data System (ADS)

    Hirose, T.; Shiba, K.; Enoeda, M.; Akiba, M.

    2007-08-01

    A water-cooled solid breeder (WCSB) blanket cooled by high temperature SCPW (super critical pressurized water) is a practical option of DEMO reactor. Therefore, it is necessary to check the compatibility of the steel with SCPW. In this work, reduced activation ferritic/martensitic steel, F82H has been tested through slow strain rate tests (SSRT) in 23.5 MPa SCPW. And weight change behavior was measured up to 1000 h. F82H did not demonstrated stress corrosion cracking and its weight simply increased with surface oxidation. The weight change of F82H was almost same as commercial 9%-Cr steels. According to a cross-sectional analysis and weight change behavior, corrosion rate of F82H in the 823 K SCPW is estimated to be 0.04 mm/yr.

  6. Stress Corrosion Cracking Behavior of Hardening-Treated 13Cr Stainless Steel

    NASA Astrophysics Data System (ADS)

    Niu, Li-Bin; Ishitake, Hisamitsu; Izumi, Sakae; Shiokawa, Kunio; Yamashita, Mitsuo; Sakai, Yoshihiro

    2018-03-01

    Stress corrosion cracking (SCC) behavior of the hardening-treated materials of 13Cr stainless steel was examined with SSRT tests and constant load tests. In the simulated geothermal water and even in the test water without addition of impurities, the hardening-treated materials showed a brittle intergranular fracture due to the sensitization, which was caused by the present hardening-treatments.

  7. Delta Clipper vehicle design for supportability

    NASA Astrophysics Data System (ADS)

    Smiljanic, Ray R.; Klevatt, Paul L.; Steinmeyer, Donald A.

    1993-02-01

    The paper describes the Single Stage Rocket Technology (SSRT) Delta Clipper vehicle design. As a means of reducing vehicle processing and turnaround times, the SSRT Delta Clipper design, contrary to past practices, incorporates support ability engineering features into its initial set of design requirements. The engineering process used to 'design-in' supportability into the Delta Clipper vehicle is described in detail and is illustrated using diagrams.

  8. Effect of Repair Welding on Electrochemical Corrosion and Stress Corrosion Cracking Behavior of TIG Welded AA2219 Aluminum Alloy in 3.5 Wt Pct NaCl Solution

    NASA Astrophysics Data System (ADS)

    Venugopal, A.; Sreekumar, K.; Raja, V. S.

    2010-12-01

    The stress corrosion cracking (SCC) behavior of AA2219 aluminum alloy in the as-welded (AW) and repair-welded (RW) conditions was examined and compared with that of the base metal (BM) in 3.5 wt pct NaCl solution using the slow strain rate technique (SSRT). The reduction in ductility was used as a parameter to evaluate the SCC susceptibility of both BM and welded joints. The results show that the ductility ratio ( ɛ NaCl/( ɛ air)) of the BM was close to one (0.97) and reduced to 0.9 for the AW joint. This value further reduced to 0.77 after carrying out one repair welding operation. However, the RW specimen exhibited higher ductility than the single-weld specimens even in 3.5 wt pct NaCl solution. SSRT results obtained using pre-exposed samples followed by post-test metallographic observations clearly showed localized pitting corrosion along the partially melted zone (PMZ), signifying that the reduction in ductility ratio of both the AW and RW joints was more due to mechanical overload failure, caused by the localized corrosion and a consequent reduction in specimen thickness, than due to SCC. Also, the RW joint exhibited higher ductility than the AW joint both in air and the environment, although SCC index (SI) for the former is lower than that of the latter. Fractographic examination of the failed samples, in general, revealed a typical ductile cracking morphology for all the base and welded joints, indicating the good environmental cracking resistance of this alloy. Microstructural examination and polarization tests further demonstrate grain boundary melting along the PMZ, and that provided the necessary electrochemical condition for the preferential cracking on that zone of the weldment.

  9. Response Inhibition in Preschoolers at Familial Risk for Attention Deficit Hyperactivity Disorder: A Behavioral and Electrophysiological Stop-Signal Study

    ERIC Educational Resources Information Center

    Berger, Andrea; Alyagon, Uri; Hadaya, Hadas; Atzaba-Poria, Naama; Auerbach, Judith G.

    2013-01-01

    Children participating in the Ben-Gurion Infant Development Study were assessed with a dynamic-tracking version of the stop-signal task at the age of 5 years. The sample consisted of 60 males. Stop-signal reaction time (SSRT) was correlated with concurrent ratings of the child's attention deficit hyperactivity disorder (ADHD) symptoms.…

  10. Hydrogen Embrittlement Susceptibility and Safety Control of Reheated CGHAZ in X80 Welded Pipeline

    NASA Astrophysics Data System (ADS)

    Deng, Qiushi; Zhao, Weimin; Jiang, Wei; Zhang, Timing; Li, Tingting; Zhao, Yujiao

    2018-03-01

    Coarse-grained heat-affected zone (CGHAZ) exhibits the highest hydrogen embrittlement (HE) susceptibility, which changes under the influence of thermal cycle. In this study, slow strain rate tension (SSRT) tests were conducted to investigate the HE susceptibility of reheated CGHAZs and the critical hydrogen pressure for fracture failure. Results show that intercritically reheated CGHAZ (ICCGHAZ) possesses the lowest HE resistance. Analyses of HE index and fracture indicate that the critical hydrogen pressure is 3.5 MPa. Microstructure analysis reveals that HE susceptibility is associated with multiple factors, such as phase composition, grain coarsening, HAB density, and MA constituent. Blocky necklace-like MA constituent along prior austenite boundaries plays a predominant role in intensifying the HE susceptibility of ICCGHAZ.

  11. Effects of Nitrogen and Tensile Direction on Stress Corrosion Cracking Susceptibility of Ni-Free FeCrMnC-Based Duplex Stainless Steels

    PubMed Central

    Ha, Heon-Young; Lee, Chang-Hoon; Lee, Tae-Ho; Kim, Sangshik

    2017-01-01

    Stress corrosion cracking (SCC) behavior of Ni-free duplex stainless steels containing N and C (Febalance-19Cr-8Mn-0.25C-(0.03, 0.21)N, in wt %) was investigated by using a slow strain rate test (SSRT) in air and aqueous NaCl solution with different tensile directions, including parallel (longitudinal) and perpendicular (transverse) to the rolling direction. It was found that alloying N was effective in increasing the resistance to SCC, while it was higher along the longitudinal direction than the transverse direction. The SCC susceptibility of the two alloys was assessed based on the electrochemical resistance to pitting corrosion, the corrosion morphology, and the fractographic analysis. PMID:28772651

  12. SU-E-T-56: Brain Metastasis Treatment Plans for Contrast-Enhanced Synchrotron Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Obeid, L; Adam, J; Tessier, A

    2014-06-01

    Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The aim of this study is to compare dynamic stereotactic arc-therapy and iodineenhanced SSRT. Methods: Five patients bearing brain metastasis received a standard helical 3D-scan without iodine. A second scan was acquired 13 min after an 80 g iodine infusion. Two SSRT treatment plans (with/without iodine) were performed for each patient using a dedicated Monte Carlo (MC) treatment planning system (TPS) based on the ISOgray TPS. Ten coplanar beams (6×6 cm2, shaped with collimator)more » were simulated. MC statistical error objective was less than 5% in the 50% isodose. The dynamic arc-therapy plan was achieved on the Iplan Brainlab TPS. The treatment plan validation criteria were fixed such that 100% of the prescribed dose is delivered at the beam isocentre and the 70% isodose contains the whole target volume. The comparison elements were the 70% isodose volume, the average and maximum doses delivered to organs at risk (OAR): brainstem, optical nerves, chiasma, eyes, skull bone and healthy brain parenchyma. Results: The stereotactic dynamic arc-therapy remains the best technique in terms of dose conformation. Iodine-enhanced SSRT presents similar performances to dynamic arc-therapy with increased brainstem and brain parenchyma sparing. One disadvantage of SSRT is the high dose to the skull bone. Iodine accumulation in metastasis may increase the dose by 20–30%, allowing a normal tissue sparing effect at constant prescribed dose. Treatment without any iodine enhancement (medium-energy stereotactic radiotherapy) is not relevant with degraded HDVs (brain, parenchyma and skull bone) comparing to stereotactic dynamic arc-therapy. Conclusion: Iodine-enhanced SSRT exhibits a good potential for brain metastasis treatment regarding the dose distribution and OAR criteria.« less

  13. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    PubMed

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  14. Environmental Assessment: Single Stage Rocket Technology DC-X Test Program

    DTIC Science & Technology

    1992-06-01

    the National Historic Preservation Act (NHPA) requires Federal agencies to consider the affects of their proposed actions on historic properties, which...activities were coordinated with the New Mexico State Historic * Preservation Office. June 1992 Uncidsifled !2-7 Environmntal Assesmnkw~ SSRTI Habitat... Preservation (ACHP), and the New Mexico State Historic Preservation Office. Compliance with Section 106 of the National Historic Preservation Act for the SSRT

  15. Space Storable Rocket Technology program (SSRT). Option 1 program

    NASA Astrophysics Data System (ADS)

    Chazen, Melvin L.; Mueller, Thomas; Rust, Thomas

    1993-08-01

    The Space Storable Rocket Technology (SSRT) Option 1 Program was initiated in October 1991 after completion of the Basic Program. The program was restructured in mid-July 1992 to incorporate a Rhenium Technology Task and reduce the scope of the LO2-N2H4 engine development. The program was also extended to late February 1993 to allow for the Rhenium Technology Task completion. The Option 1 Program was devoted to evaluation of two new injector elements, evaluation of two different methods of thermal protection of the injector, evaluation of high temperature material properties of rhenium and evaluation of methods of joining the rhenium thrust chamber to the columbium injector and nozzle extension. In addition, critical experiments were conducted (Funded by Option 2) to evaluate mechanisms to understand the effects of GO2 injection into the chamber, helium injection into the main LO2, effect of the splash plate and effect of decreasing the aspect ratio of the 120-slot (-13a) element. The performance and thermal models were used to further correlate the test results with analyses. The results of the work accomplished are summarized.

  16. Space Storable Rocket Technology program (SSRT). Option 1 program

    NASA Technical Reports Server (NTRS)

    Chazen, Melvin L.; Mueller, Thomas; Rust, Thomas

    1993-01-01

    The Space Storable Rocket Technology (SSRT) Option 1 Program was initiated in October 1991 after completion of the Basic Program. The program was restructured in mid-July 1992 to incorporate a Rhenium Technology Task and reduce the scope of the LO2-N2H4 engine development. The program was also extended to late February 1993 to allow for the Rhenium Technology Task completion. The Option 1 Program was devoted to evaluation of two new injector elements, evaluation of two different methods of thermal protection of the injector, evaluation of high temperature material properties of rhenium and evaluation of methods of joining the rhenium thrust chamber to the columbium injector and nozzle extension. In addition, critical experiments were conducted (Funded by Option 2) to evaluate mechanisms to understand the effects of GO2 injection into the chamber, helium injection into the main LO2, effect of the splash plate and effect of decreasing the aspect ratio of the 120-slot (-13a) element. The performance and thermal models were used to further correlate the test results with analyses. The results of the work accomplished are summarized.

  17. Environmentally assisted cracking in light water reactors.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chopra, O. K.; Chung, H. M.; Clark, R. W.

    2007-11-06

    This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors (LWRs) from January to December 2002. Topics that have been investigated include: (a) environmental effects on fatigue crack initiation in carbon and low-alloy steels and austenitic stainless steels (SSs), (b) irradiation-assisted stress corrosion cracking (IASCC) of austenitic SSs in BWRs, (c) evaluation of causes and mechanisms of irradiation-assisted cracking of austenitic SS in PWRs, and (d) cracking in Ni-alloys and welds. A critical review of the ASME Code fatigue design margins and an assessment of the conservation in the currentmore » choice of design margins are presented. The existing fatigue {var_epsilon}-N data have been evaluated to define the effects of key material, loading, and environmental parameters on the fatigue lives of carbon and low-alloy steels and austenitic SSs. Experimental data are presented on the effects of surface roughness on fatigue crack initiation in these materials in air and LWR environments. Crack growth tests were performed in BWR environments on SSs irradiated to 0.9 and 2.0 x 10{sup 21} n x cm{sup -2}. The crack growth rates (CGRs) of the irradiated steels are a factor of {approx}5 higher than the disposition curve proposed in NUREG-0313 for thermally sensitized materials. The CGRs decreased by an order of magnitude in low-dissolved oxygen (DO) environments. Slow-strain-rate tensile (SSRT) tests were conducted in high-purity 289 C water on steels irradiated to {approx}3 dpa. The bulk S content correlated well with the susceptibility to intergranular SCC in 289 C water. The IASCC susceptibility of SSs that contain >0.003 wt. % S increased drastically. bend tests in inert environments at 23 C were conducted on broken pieces of SSRT specimens and on unirradiated specimens of the same materials after hydrogen charging. The results of the tests and a review of other data in the literature indicate that IASCC in 289 C water is dominated by a crack-tip grain-boundary process that involves S. An initial IASCC model has been proposed. A crack growth test was completed on mill annealed Alloy 600 in high-purity water at 289 C and 320 C under various environmental and loading conditions. The results from this test are compared with data obtained earlier on several other heats of Alloy 600.« less

  18. Stress Corrosion Cracking Behavior of Multipass TIG-Welded AA2219 Aluminum Alloy in 3.5 wt pct NaCl Solution

    NASA Astrophysics Data System (ADS)

    Venugopal, A.; Sreekumar, K.; Raja, V. S.

    2012-09-01

    The stress corrosion cracking (SCC) behavior of the AA2219 aluminum alloy in the single-pass (SP) and multipass (MP) welded conditions was examined and compared with that of the base metal (BM) in 3.5 wt pct NaCl solution using a slow-strain-rate technique (SSRT). The reduction in ductility was used as a parameter to evaluate the SCC susceptibility of both the BM and welded joints. The results showed that the ductility ratio ( ɛ NaCl/( ɛ air) was 0.97 and 0.96, respectively, for the BM and MP welded joint, and the same was marginally reduced to 0.9 for the SP welded joint. The fractographic examination of the failed samples revealed a typical ductile cracking morphology for all the base and welded joints, indicating the good environmental cracking resistance of this alloy under all welded conditions. To understand the decrease in the ductility of the SP welded joint, preexposure SSRT followed by microstructural observations were made, which showed that the decrease in ductility ratio of the SP welded joint was caused by the electrochemical pitting that assisted the nucleation of cracks in the form of corrosion induced mechanical cracking rather than true SCC failure of the alloy. The microstructural examination and polarization tests demonstrated a clear grain boundary (GB) sensitization of the PMZ, resulting in severe galvanic corrosion of the SP weld joint, which initiated the necessary conditions for the localized corrosion and cracking along the PMZ. The absence of PMZ and a refined fusion zone (FZ) structure because of the lesser heat input and postweld heating effect improved the galvanic corrosion resistance of the MP welded joint greatly, and thus, failure occurred along the FZ.

  19. Theta burst magnetic stimulation over the pre-supplementary motor area improves motor inhibition.

    PubMed

    Obeso, Ignacio; Wilkinson, Leonora; Teo, James T; Talelli, Penelope; Rothwell, John C; Jahanshahi, Marjan

    Stopping an ongoing motor response or resolving conflict induced by conflicting stimuli are associated with activation of a right-lateralized network of inferior frontal gyrus (IFG), pre-supplementary motor area (pre-SMA) and subthalamic nucleus (STN). However, the roles of the right IFG and pre-SMA in stopping a movement and in conflict resolution remain unclear. We used continuous theta burst stimulation (cTBS) to examine the involvement of the right IFG and pre-SMA in inhibition and conflict resolution using the conditional stop signal task. We measured stop signal reaction time (SSRT, measure of reactive inhibition), response delay effect (RDE, measure of proactive action restraint) and conflict induced slowing (CIS, measure of conflict resolution). Stimulation over the pre-SMA resulted in significantly shorter SSRTs (improved inhibition) compared to sham cTBS. This effect was not observed for CIS, RDE, or any other measures. cTBS over the right IFG had no effect on SSRT, CIS, RDE or on any other measure. The improvement of SSRT with cTBS over the pre-SMA suggests its critical contribution to stopping ongoing movements. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    NASA Astrophysics Data System (ADS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  1. Use of electrochemical potential noise to detect initiation and propagation of stress corrosion cracks in a 17-4 PH steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez-Rodriguez, J.G.; Salinas-Bravo, V.M.; Garcia-Ochoa, E.

    1997-09-01

    Corrosion potential transients were associated with nucleation and propagation of stress corrosion cracks in a 17-4 precipitation-hardenable (PH) martensitic stainless steel (SS) during slow strain rate tests (SSRT) at 90 C in deaerated sodium chloride (NaCl) solutions, Test solutions included 20 wt% NaCl at pH 3 and 7, similar to normal and faulted steam turbine environments, respectively. Time series were analyzed using the fast Fourier transform method. At the beginning of straining, the consistent noise behavior was perturbed with small potential transients, probably associated with rupture of the surface oxide layer. After yielding, these transients increased in intensity. At maximummore » load, the transients were still higher in intensity and frequency. These potential transients were related to crack nucleation and propagation. When the steel did not fail by stress corrosion cracking (SCC), such transients were found only at the beginning of the test. The power spectra showed some differences in all cases in roll-off slope and voltage magnitude, but these were not reliable tools to monitor the initiation and propagation of stress corrosion cracks.« less

  2. Alcohol Preferring P Rats Exhibit Elevated Motor Impulsivity Concomitant with Operant Responding and Self-Administration of Alcohol

    PubMed Central

    Beckwith, Steven Wesley; Czachowski, Cristine Lynn

    2016-01-01

    Background Increased levels of impulsivity are associated with increased illicit drug use and alcoholism. Previous research in our lab has shown that increased levels of delay discounting (a decision-making form of impulsivity) are related to appetitive processes governing alcohol self-administration as opposed to purely consummatory processes. Specifically, the high seeking/high drinking alcohol preferring P rats showed increased delay discounting compared to nonselected Long Evans rats (LE) whereas the high drinking/moderate seeking HAD2 rats did not (Beckwith & Czachowski, 2014). The P rats also displayed a perseverative pattern of behavior such that during operant alcohol self-administration they exhibited greater resistance to extinction. Methods One explanation for the previous findings is that P rats have a deficit in response inhibition. The current study followed up on this possibility by utilizing a countermanding paradigm [stop signal reaction time (SSRT) task] followed by operant self-administration of alcohol across increasing fixed ratio requirements (FR; 1, 2, 5, 10 & 15 responses). In separate animals, 24hr access 2-bottle choice (10% EtOH vs. water) drinking was assessed. Results In the SSRT task, P rats exhibited an increased SSRT compared to both LE and HAD2 rats indicating a decrease in behavioral inhibition in the P rats. Also, P rats showed increased operant self-administration across all FRs and the greatest increase in responding with increasing FR requirements. Conversely, the HAD2 and LE had shorter SSRT, and lower levels of operant alcohol self-administration. However, for 2 bottle choice drinking HAD2s and P rats consumed more EtOH as well as had a greater preference for EtOH compared to LE. Conclusions These data extend previous findings showing the P rats to have increased delay discounting (decision-making impulsivity) and suggest that P rats also have a lack of behavioral inhibition (motor impulsivity). This supports the notion that P rats are a highly impulsive as well as “high seeking” model of alcoholism, and that the HAD2s elevated levels of alcohol consumption are not mediated via appetitive processes or impulsivity. PMID:27028842

  3. Field studies of safety security rescue technologies through training and response activities

    NASA Astrophysics Data System (ADS)

    Murphy, Robin R.; Stover, Sam

    2006-05-01

    This paper describes the field-oriented philosophy of the Institute for Safety Security Rescue Technology (iSSRT) and summarizes the activities and lessons learned during calendar year 2005 of its two centers: the Center for Robot-Assisted Search and Rescue and the NSF Safety Security Rescue industry/university cooperative research center. In 2005, iSSRT participated in four responses (La Conchita, CA, Mudslides, Hurricane Dennis, Hurricane Katrina, Hurricane Wilma) and conducted three field experiments (NJTF-1, Camp Hurricane, Richmond, MO). The lessons learned covered mobility, operator control units, wireless communications, and general reliability. The work has collectively identified six emerging issues for future work. Based on these studies, a 10-hour, 1 continuing education unit credit course on rescue robotics has been created and is available. Rescue robots and sensors are available for loan upon request.

  4. Within-Subject Correlation Analysis to Detect Functional Areas Associated With Response Inhibition.

    PubMed

    Yamasaki, Tomoko; Ogawa, Akitoshi; Osada, Takahiro; Jimura, Koji; Konishi, Seiki

    2018-01-01

    Functional areas in fMRI studies are often detected by brain-behavior correlation, calculating across-subject correlation between the behavioral index and the brain activity related to a function of interest. Within-subject correlation analysis is also employed in a single subject level, which utilizes cognitive fluctuations in a shorter time period by correlating the behavioral index with the brain activity across trials. In the present study, the within-subject analysis was applied to the stop-signal task, a standard task to probe response inhibition, where efficiency of response inhibition can be evaluated by the stop-signal reaction time (SSRT). Since the SSRT is estimated, by definition, not in a trial basis but from pooled trials, the correlation across runs was calculated between the SSRT and the brain activity related to response inhibition. The within-subject correlation revealed negative correlations in the anterior cingulate cortex and the cerebellum. Moreover, the dissociation pattern was observed in the within-subject analysis when earlier vs. later parts of the runs were analyzed: negative correlation was dominant in earlier runs, whereas positive correlation was dominant in later runs. Regions of interest analyses revealed that the negative correlation in the anterior cingulate cortex, but not in the cerebellum, was dominant in earlier runs, suggesting multiple mechanisms associated with inhibitory processes that fluctuate on a run-by-run basis. These results indicate that the within-subject analysis compliments the across-subject analysis by highlighting different aspects of cognitive/affective processes related to response inhibition.

  5. Reaction Time Variability Associated with Reading Skills in Poor Readers with ADHD

    PubMed Central

    Tamm, Leanne; Epstein, Jeffery N.; Denton, Carolyn A.; Vaughn, Aaron J.; Peugh, James; Willcutt, Erik G.

    2014-01-01

    Objective Linkages between neuropsychological functioning (i.e., response inhibition, processing speed, reaction time variability) and word reading have been documented among children with Attention-Deficit/Hyperactivity Disorder (ADHD) and children with Reading Disorders. However, associations between neuropsychological functioning and other aspects of reading (i.e., fluency, comprehension) have not been well-documented among children with comorbid ADHD and Reading Disorder. Method Children with ADHD and poor word reading (i.e., ≤25th percentile) completed a stop signal task (SST) and tests of word reading, reading fluency, and reading comprehension. Multivariate multiple regression was conducted predicting the reading skills from SST variables [i.e., mean reaction time (MRT), reaction time standard deviation (SDRT), and stop signal reaction time (SSRT)]. Results SDRT predicted word reading, reading fluency, and reading comprehension. MRT and SSRT were not associated with any reading skill. After including word reading in models predicting reading fluency and reading comprehension, the effects of SDRT were minimized. Discussion Reaction time variability (i.e., SDRT) reflects impairments in information processing and failure to maintain executive control. The pattern of results from this study suggest SDRT exerts its effects on reading fluency and reading comprehension through its effect on word reading (i.e., decoding) and that this relation may be related to observed deficits in higher-level elements of reading. PMID:24528537

  6. Corrective response times in a coordinated eye-head-arm countermanding task.

    PubMed

    Tao, Gordon; Khan, Aarlenne Z; Blohm, Gunnar

    2018-06-01

    Inhibition of motor responses has been described as a race between two competing decision processes of motor initiation and inhibition, which manifest as the reaction time (RT) and the stop signal reaction time (SSRT); in the case where motor initiation wins out over inhibition, an erroneous movement occurs that usually needs to be corrected, leading to corrective response times (CRTs). Here we used a combined eye-head-arm movement countermanding task to investigate the mechanisms governing multiple effector coordination and the timing of corrective responses. We found a high degree of correlation between effector response times for RT, SSRT, and CRT, suggesting that decision processes are strongly dependent across effectors. To gain further insight into the mechanisms underlying CRTs, we tested multiple models to describe the distribution of RTs, SSRTs, and CRTs. The best-ranked model (according to 3 information criteria) extends the LATER race model governing RTs and SSRTs, whereby a second motor initiation process triggers the corrective response (CRT) only after the inhibition process completes in an expedited fashion. Our model suggests that the neural processing underpinning a failed decision has a residual effect on subsequent actions. NEW & NOTEWORTHY Failure to inhibit erroneous movements typically results in corrective movements. For coordinated eye-head-hand movements we show that corrective movements are only initiated after the erroneous movement cancellation signal has reached a decision threshold in an accelerated fashion.

  7. Cracking characteristics of alloy 690 in thiosulfate containing chloride solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, H.H.; Tsai, W.T.

    1999-07-01

    The cracking characteristics of Alloy 690 in deaerated 1wt% NaCl solution with different Na{sub 2}S{sub 2}O{sub 2} concentrations, namely 0.01, 0.1, 0.2 and 0.5 M, at controlled anodic potentials was investigated by using slow strain rate testing (SSRT) with a strain rate of 1 x 10{sup {minus}6} s{sup {minus}1}. The results showed that the ultimate tensile strength and the ductility increased with increasing the concentration of Na{sub 2}S{sub 2}O{sub 3} at the same anodic potential, but decreased with increasing potential at a fixed concentration of Na{sub 2}S{sub 2}O{sub 3}. Pitting corrosion could occur on Alloy 690 in 1wt% NaCl solutionmore » with the concentration of Na{sub 2}S{sub 2}O{sub 3} {le} 0.1 M, depending on the potential. The susceptibilities of Alloy 690 to pitting corrosion and environmentally-assisted cracking in 1wt% NaCl solution were inhibited with the concentration of Na{sub 2}S{sub 2}O{sub 3} {ge} 0.2M, regardless of the potential.« less

  8. Synchrotron Radiation Therapy from a Medical Physics point of view

    NASA Astrophysics Data System (ADS)

    Prezado, Y.; Adam, J. F.; Berkvens, P.; Martinez-Rovira, I.; Fois, G.; Thengumpallil, S.; Edouard, M.; Vautrin, M.; Deman, P.; Bräuer-Krisch, E.; Renier, M.; Elleaume, H.; Estève, F.; Bravin, A.

    2010-07-01

    Synchrotron radiation (SR) therapy is a promising alternative to treat brain tumors, whose management is limited due to the high morbidity of the surrounding healthy tissues. Several approaches are being explored by using SR at the European Synchrotron Radiation Facility (ESRF), where three techniques are under development Synchrotron Stereotactic Radiation Therapy (SSRT), Microbeam Radiation Therapy (MRT) and Minibeam Radiation Therapy (MBRT). The sucess of the preclinical studies on SSRT and MRT has paved the way to clinical trials currently in preparation at the ESRF. With this aim, different dosimetric aspects from both theoretical and experimental points of view have been assessed. In particular, the definition of safe irradiation protocols, the beam energy providing the best balance between tumor treatment and healthy tissue sparing in MRT and MBRT, the special dosimetric considerations for small field dosimetry, etc will be described. In addition, for the clinical trials, the definition of appropiate dosimetry protocols for patients according to the well established European Medical Physics recommendations will be discussed. Finally, the state of the art of the MBRT technical developments at the ESRF will be presented. In 2006 A. Dilmanian and collaborators proposed the use of thicker microbeams (0.36-0.68 mm). This new type of radiotherapy is the most recently implemented technique at the ESRF and it has been called MBRT. The main advantage of MBRT with respect to MRT is that it does not require high dose rates. Therefore it can be more easily applied and extended outside synchrotron sources in the future.

  9. Cardiac autonomic regulation as a predictor for childhood obesity intervention success.

    PubMed

    Taylor, M J; Vlaev, I; Taylor, D; Kulendran, M; Gately, P; Al-Kuwari, H; Darzi, A; Ahmedna, M

    2017-05-01

    Childhood obesity is a major public health concern; behavioural interventions induce weight reduction in some, but success is variable. Heart rate variability (HRV) has been associated with impulse control and extent of dieting success. This study investigated the relationship between HRV and post childhood obesity intervention weight-management success, and involved recording the frequency-domain HRV measures ratio between low frequency and high frequency power (LF/HF) and high frequency power (HF), and the time-domain measure, percentage of successive beat-to-beat intervals that differ by more than 50ms (PNN50). It was expected that greater LF/HF and lower HF would be associated with greater post-intervention weight gain, and that greater PNN50 would be associated with greater impulse control. Seventy-four participants aged 9-14 (M=10.7; s.d.: 1.1) attended a weight-management camp, where HRV was recorded. Stop signal reaction time (SSRT) was also recorded as a measure of impulse control. As expected, SSRT was positively associated with pre-intervention body mass (r=0.301, P=0.010) and negatively associated with PNN50 (β=0.29, P=0.031). Post-intervention body mass change was positively associated with LF/HF (β=0.34, P=0.037), but was not associated with HF. Lifestyle interventions may have a greater chance of effectively supporting long-term weight-management for children with lower LF/HF; assessing HRV of obese children may be helpful in informing obesity treatment decisions.

  10. Aging and inhibitory control of action: cortico-subthalamic connection strength predicts stopping performance.

    PubMed

    Coxon, James P; Van Impe, Annouchka; Wenderoth, Nicole; Swinnen, Stephan P

    2012-06-13

    Diffusion weighted imaging (DWI) studies in humans have shown that seniors exhibit reduced white matter integrity compared with young adults, with the most pronounced change occurring in frontal white matter. It is generally assumed that this structural deterioration underlies inhibitory control deficits in old age, but specific evidence from a structural neuroscience perspective is lacking. Cognitive action control is thought to rely on an interconnected network consisting of right inferior frontal cortex (r-IFC), pre-supplementary motor area (preSMA), and the subthalamic nucleus (STN). Here we performed probabilistic DWI tractography to delineate this cognitive control network and had the same individuals (20 young, 20 older adults) perform a task probing both response inhibition and action reprogramming. We hypothesized that structural integrity (fractional anisotropy) and connection strength within this network would be predictive of individual and age-related differences in task performance. We show that the integrity of r-IFC white matter is an age-independent predictor of stop-signal reaction time (SSRT). We further provide evidence that the integrity of white matter projecting to STN predicts both outright stopping (SSRT) and transient braking of response initiation to buy time for action reprogramming (stopping interference effects). These associations remain even after controlling for Go task performance, demonstrating specificity to the Stop component of this task. Finally, a multiple regression analysis reveals bilateral preSMA-STN tract strength as a significant predictor of SSRT in older adults. Our data link age-related decline in inhibitory control with structural decline of STN projections.

  11. Comprehensive Understanding of Ductility Loss Mechanisms in Various Steels with External and Internal Hydrogen

    NASA Astrophysics Data System (ADS)

    Takakuwa, Osamu; Yamabe, Junichiro; Matsunaga, Hisao; Furuya, Yoshiyuki; Matsuoka, Saburo

    2017-11-01

    Hydrogen-induced ductility loss and related fracture morphologies are comprehensively discussed in consideration of the hydrogen distribution in a specimen with external and internal hydrogen by using 300-series austenitic stainless steels (Types 304, 316, 316L), high-strength austenitic stainless steels (HP160, XM-19), precipitation-hardened iron-based super alloy (A286), low-alloy Cr-Mo steel (JIS-SCM435), and low-carbon steel (JIS-SM490B). External hydrogen is realized by a non-charged specimen tested in high-pressure gaseous hydrogen, and internal hydrogen is realized by a hydrogen-charged specimen tested in air or inert gas. Fracture morphologies obtained by slow-strain-rate tensile tests (SSRT) of the materials with external or internal hydrogen could be comprehensively categorized into five types: hydrogen-induced successive crack growth, ordinary void formation, small-sized void formation related to the void sheet, large-sized void formation, and facet formation. The mechanisms of hydrogen embrittlement are broadly classified into hydrogen-enhanced decohesion (HEDE) and hydrogen-enhanced localized plasticity (HELP). In the HEDE model, hydrogen weakens interatomic bonds, whereas in the HELP model, hydrogen enhances localized slip deformations. Although various fracture morphologies are produced by external or internal hydrogen, these morphologies can be explained by the HELP model rather than by the HEDE model.

  12. Effect of solution treatment on stress corrosion cracking behavior of an as-forged Mg-Zn-Y-Zr alloy

    PubMed Central

    Wang, S. D.; Xu, D. K.; Wang, B. J.; Sheng, L. Y.; Han, E. H.; Dong, C.

    2016-01-01

    Effect of solid solution treatment (T4) on stress corrosion cracking (SCC) behavior of an as-forged Mg-6.7%Zn-1.3%Y-0.6%Zr (in wt.%) alloy has been investigated using slow strain rate tensile (SSRT) testing in 3.5 wt.% NaCl solution. The results demonstrated that the SCC susceptibility index (ISCC) of as-forged samples was 0.95 and its elongation-to-failure (εf) was only 1.1%. After T4 treatment, the SCC resistance was remarkably improved. The ISCC and εf values of T4 samples were 0.86 and 3.4%, respectively. Fractography and surface observation indicated that the stress corrosion cracking mode for as-forged samples was dominated by transgranular and partially intergranular morphology, whereas the cracking mode for T4 samples was transgranular. In both cases, the main cracking mechanism was associated with hydrogen embrittlement (HE). Through alleviating the corrosion attack of Mg matrix, the influence of HE on the SCC resistance of T4 samples can be greatly suppressed. PMID:27387817

  13. In-vitro biodegradation and corrosion-assisted cracking of a coated magnesium alloy in modified-simulated body fluid.

    PubMed

    Jafari, Sajjad; Singh Raman, R K

    2017-09-01

    A calcium phosphate coating was directly synthesized on AZ91D magnesium (Mg) alloy. Resistance of this coating to corrosion in a modified-simulated body fluid (m-SBF) was investigated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Mechanical properties of the bare and coated alloy were investigated using slow strain rate tensile (SSRT) and fatigue testing in air and m-SBF. Very little is reported in the literature on human-body-fluid-assisted cracking of Mg alloys, viz., resistance to corrosion fatigue (CF) and stress corrosion cracking (SCC). This study has a particular emphasis on the effect of bio-compatible coatings on mechanical and electrochemical degradations of Mg alloys for their applications as implants. The results suggest the coating to improve the general as well as pitting corrosion resistance of the alloy. The coating also provides visible improvement in resistance to SCC, but little improvement in CF resistance. This is explained on the basis of pitting behaviour in the presence and absence of the coating. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Motivational Influences on Response Inhibition Measures

    ERIC Educational Resources Information Center

    Leotti, Lauren A.; Wager, Tor D.

    2010-01-01

    Psychological research has placed great emphasis on inhibitory control due to its integral role in normal cognition and clinical disorders. The stop-signal task and associated measure--stop-signal reaction time (SSRT)--provides a well-established paradigm for measuring response inhibition. However, motivational influences on stop-signal…

  15. LSP/MAO composite bio-coating on AZ80 magnesium alloy for biomedical application.

    PubMed

    Xiong, Ying; Hu, Qiang; Song, Renguo; Hu, Xiaxia

    2017-06-01

    A composite bio-coating was fabricated on AZ80 magnesium (Mg) alloy by using micro-arc oxidation (MAO) under the pretreatment of laser shock peening (LSP) in order to improve the bio-corrosion resistance and the mechanical integrity. LSP treatment could induce grain refinement and compressive residual stress field on the surface of material. MAO bio-coating was grown in alkaline electrolyte with hydroxyapatite (HA, Ca 10 (PO4) 6 (OH) 2 ) to improve the biological properties of the material. The microstructure, element and phase composition for untreated based material (BM) and treated samples (LSP layer, MAO bio-coating and LSP/MAO composite bio-coating) were investigated by transmission electron microscopy (TEM), scanning electron microscope (SEM), energy dispersion spectroscopy (EDS) and X-ray diffraction (XRD). Electrochemical tests and slow strain rate tensile (SSRT) tests were used to evaluate the corrosion resistance and the stress corrosion susceptibility in simulated body fluid (SBF). The results indicated that LSP/MAO composite bio-coating can not only improve the corrosion resistance of Mg alloy substrate evidently but also increase the mechanical properties in SBF compared to LSP layer and MAO bio-coating. Mg alloy treated by LSP/MAO composite technique should be better suited as biodegradable orthopedic implants. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Acting without being in control: Exploring volition in Parkinson's disease with impulsive compulsive behaviours.

    PubMed

    Ricciardi, Lucia; Haggard, Patrick; de Boer, Lieke; Sorbera, Chiara; Stenner, Max-Philipp; Morgante, Francesca; Edwards, Mark J

    2017-07-01

    Several aspects of volitional control of action may be relevant in the pathophysiology of impulsive-compulsive behaviours (ICB) in Parkinson's disease (PD). We aimed to explore multiple aspects of action control, assessing reward-related behaviour, inhibition (externally and internally triggered) and sense of agency in PD patients, with and without ICB compared to healthy subjects. Nineteen PD patients with ICB (PD-ICB), 19 PD without ICB (PD-no-ICB) and 19 healthy controls (HC) underwent a battery of tests including: Intentional Binding task which measures sense of agency; Stop Signal Reaction Time (SSRT) measuring capacity for reactive inhibition; the Marble task, assessing intentional inhibition; Balloon Analog Risk Task for reward sensitivity. One-way ANOVA showed significant main effect of group for action binding (p = 0.004, F = 6.27). Post hoc analysis revealed that PD-ICB had significantly stronger action binding than HC (p = 0.004), and PD-no-ICB (p = 0.04). There was no difference between PD-no-ICB and HC. SSRT did not differ between PD groups, whereas a significant difference between PD-no-ICB and HC was detected (p = 0.01). No other differences were found among groups in the other tasks. PD patients with ICB have abnormal performance on a psychophysical task assessing sense of agency, which might be related to a deficit in action representation at cognitive/experiential level. Yet, they have no deficit on tasks evaluating externally and internally triggered inhibitory control, or in reward-based decision-making. We conclude that impaired sense of agency may be a factor contributing to ICB in PD patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Factors affecting stress assisted corrosion cracking of carbon steel under industrial boiler conditions

    NASA Astrophysics Data System (ADS)

    Yang, Dong

    Failure of carbon steel boiler tubes from waterside has been reported in the utility boilers and industrial boilers for a long time. In industrial boilers, most waterside tube cracks are found near heavy attachment welds on the outer surface and are typically blunt, with multiple bulbous features indicating a discontinuous growth. These types of tube failures are typically referred to as stress assisted corrosion (SAC). For recovery boilers in the pulp and paper industry, these failures are particularly important as any water leak inside the furnace can potentially lead to smelt-water explosion. Metal properties, environmental variables, and stress conditions are the major factors influencing SAC crack initation and propagation in carbon steel boiler tubes. Slow strain rate tests (SSRT) were conducted under boiler water conditions to study the effect of temperature, oxygen level, and stress conditions on crack initation and propagation on SA-210 carbon steel samples machined out of boiler tubes. Heat treatments were also performed to develop various grain size and carbon content on carbon steel samples, and SSRTs were conducted on these samples to examine the effect of microstructure features on SAC cracking. Mechanisms of SAC crack initation and propagation were proposed and validated based on interrupted slow strain tests (ISSRT). Water chemistry guidelines are provided to prevent SAC and fracture mechanics model is developed to predict SAC failure on industrial boiler tubes.

  18. Conflict anticipation in alcohol dependence - A model-based fMRI study of stop signal task.

    PubMed

    Hu, Sien; Ide, Jaime S; Zhang, Sheng; Sinha, Rajita; Li, Chiang-Shan R

    2015-01-01

    Our previous work characterized altered cerebral activations during cognitive control in individuals with alcohol dependence (AD). A hallmark of cognitive control is the ability to anticipate changes and adjust behavior accordingly. Here, we employed a Bayesian model to describe trial-by-trial anticipation of the stop signal and modeled fMRI signals of conflict anticipation in a stop signal task. Our goal is to characterize the neural correlates of conflict anticipation and its relationship to response inhibition and alcohol consumption in AD. Twenty-four AD and 70 age and gender matched healthy control individuals (HC) participated in the study. fMRI data were pre-processed and modeled with SPM8. We modeled fMRI signals at trial onset with individual events parametrically modulated by estimated probability of the stop signal, p(Stop), and compared regional responses to conflict anticipation between AD and HC. To address the link to response inhibition, we regressed whole-brain responses to conflict anticipation against the stop signal reaction time (SSRT). Compared to HC (54/70), fewer AD (11/24) showed a significant sequential effect - a correlation between p(Stop) and RT during go trials - and the magnitude of sequential effect is diminished, suggesting a deficit in proactive control. Parametric analyses showed decreased learning rate and over-estimated prior mean of the stop signal in AD. In fMRI, both HC and AD responded to p(Stop) in bilateral inferior parietal cortex and anterior pre-supplementary motor area, although the magnitude of response increased in AD. In contrast, HC but not AD showed deactivation of the perigenual anterior cingulate cortex (pgACC). Furthermore, deactivation of the pgACC to increasing p(Stop) is positively correlated with the SSRT in HC but not AD. Recent alcohol consumption is correlated with increased activation of the thalamus and cerebellum in AD during conflict anticipation. The current results highlight altered proactive control that may serve as an additional behavioral and neural marker of alcohol dependence.

  19. Cross-cultural standardization of the South Texas Assessment of Neurocognition in India.

    PubMed

    Cherkil, S; Satish, S; Mathew, S S; Dinesh, N; Kumar, C T S; Lombardo, L E; Glahn, D C; Frangou, S

    2012-08-01

    Despite the central role of cognition for mental disorders most studies have been conducted in western countries. Similar research from other parts of the world, particularly India, is very limited. As a first step in closing this gap this cross-cultural comparability study of the South Texas Assessment of Neurocognition (STAN) battery was conducted between USA and India. One hundred healthy adults from Kerala, India, were administered six language independent subtests of the Java Neuropsychological Test (JANET) version of the STAN, assessing aspects of general intellectual ability (Matrix Reasoning), attention (Identical Pairs Continuous Performance, 3 Symbol Version Test; IPCPTS), working memory (Spatial Capacity Delayed Response Test; SCAP), response inhibition (Stop Signal Reaction Time; SSRT), Emotional Recognition and Risk taking (Balloon Analogue Risk Task; BART). Test results were compared to a demographically matched US sample. Overall test performance in the Kerala sample was comparable to that of the US sample and commensurate to that generally described in studies from western countries. Our results support the metric equivalence of currently available cognitive test batteries developed in western countries for use in India. However, the sample was restricted to individuals who were literate and had completed basic primary and secondary education.

  20. 99mTc-EDDA/HYNIC-TOC somatostatin receptor scintigraphy in daily clinical practice.

    PubMed

    Chrapko, Beata Ewa; Nocuń, Anna; Gołebiewska, Renata; Stefaniak, Bogusław; Korobowicz, Elzbieta; Czekajska-Chehab, Elzbieta; Sawicki, Marek; Polkowski, Wojciech Piotr

    2010-04-01

    This study aimed to assess the impact of 99mTc-EDDA/HYNIC-TOC (99mTc-TOC) somatostatin receptor scintigraphy (SRS) in clinical practice. One hundred seventeen patients were divided into 6 groups: 1, initial detection and localization of suspected neuroendocrine tumor (NET); 2, tumor staging before therapy; 3, staging of NET of unknown origin, 4, restaging after surgery of primary tumor; 5, diagnosis of solitary pulmonary nodules (SPNs), and 6, follow-up after "cold" somatostatin analogues treatment. In group 1, clinical suspicions were not confirmed in any of the patients; in group 2, most of the primary lesions showed overexpression of somatostatin receptors (SSRT); in group 3, the primary tumor was not identified in any of the patients; in group 4, recurrences were depicted in 7 out of 47 patients; in group 5, only 1 malignant SPN was detected, and in group 6, regression of primary mass and metastases were seen on follow-up SRS in 1 patient. 99mTc-TOC SRS is useful in staging of SSRT-overexpressing tumors of known and unknown primary origin, as well as in restaging after primary tumor surgery. This method is less effective in detecting suspected NET and assessing SPNs. Further investigation is necessary to evaluate the usefulness of SRS in monitoring patients after biological treatment.

  1. Project management lessons learned on SDIO's Delta Star and Single Stage Rocket Technology programs

    NASA Technical Reports Server (NTRS)

    Klevatt, Paul L.

    1992-01-01

    The topics are presented in viewgraph form and include the following: a Delta Star (Delta 183) Program Overview, lessons learned, and rapid prototyping and the Single Stage Rocket Technology (SSRT) Program. The basic objective of the Strategic Defense Initiative Programs are to quickly reduce key uncertainties to a manageable range of parameters and solutions, and to yield results applicable to focusing subsequent research dollars on high payoff areas.

  2. Romantic Love Is Associated with Enhanced Inhibitory Control in an Emotional Stop-Signal Task

    PubMed Central

    Song, Sensen; Zou, Zhiling; Song, Hongwen; Wang, Yongming; d’Oleire Uquillas, Federico; Wang, Huijun; Chen, Hong

    2016-01-01

    Purpose: This study explored whether romantic lovers differ in emotion-related inhibitory control capacity from those who are single. Methods: 88 healthy undergraduate college students participated in the study. Half were currently in love and in a romantic relationship (love group, LG), and half were single and had never been in a romantic relationship (single group, SG). Based on duration of romantic relationship (i.e., love duration), the LG were further divided into two subgroups: “early stage love” and “longer periods of love”. All participants completed an emotional Stop Signal Task, consisting of a variety of human face stimuli displaying either sad or neutral affect. Results: Results found that relative to SG, lovers showed greater inhibitory control [shorter stop-signal reaction time (SSRT)] during negative emotion condition trials. Furthermore, in early stages of love, SSRT for negative emotion condition trials was significantly shorter compared to that in “longer periods of love” or SG individuals, with no significant differences between the two latter groups. Conclusion: Compared with individuals who were single, early stage lovers showed greater capacity for inhibiting action during presentation of negative emotional stimuli. Within a greater social context, greater inhibitory control capacity during early stages of love may be related to the successful formation of romantic relationships, particularly to the ability to persevere in goal-directed action despite negative emotional contexts such as that of sadness. PMID:27826260

  3. Effect of the Microstructure and Distribution of the Second Phase on the Stress Corrosion Cracking of Biomedical Mg-Zn-Zr-xSr Alloys

    PubMed Central

    Chen, Lianxi; Sheng, Yinying; Zhao, Xueyang; Liu, Hui; Li, Wei

    2018-01-01

    The stress corrosion cracking (SCC) properties of the bi-directional forged (BDF) Mg-4Zn-0.6Zr-xSr (ZK40-xSr, x = 0, 0.4, 0.8, 1.2, 1.6 wt %) alloys were studied by the slow strain rate tensile (SSRT) testing in modified simulated body fluid (m-SBF). The average grain size of the BDF alloys were approximately two orders of magnitude smaller than those of the as-cast alloys. However, grain refinement increased the hydrogen embrittlement effect, leading to a higher SCC susceptibility in the BDF ZK40-0/0.4Sr alloys. Apart from the grain refinements effect, the forging process also changed the distribution of second phase from the net-like shape along the grain boundary to a uniformly isolated island shape in the BDF alloys. The SCC susceptibility of the BDF ZK40-1.2/1.6Sr alloys were lower than those of the as-cast alloys. The change of distribution of the second phase suppressed the adverse effect of Sr on the SCC susceptibility in high Sr–containing magnesium alloys. The results indicated the stress corrosion behavior of magnesium alloys was related to the average grain size of matrix and the distribution and shape of the second phase. PMID:29614043

  4. Bilateral stimulation of the subthalamic nucleus has differential effects on reactive and proactive inhibition and conflict-induced slowing in Parkinson's disease.

    PubMed

    Obeso, Ignacio; Wilkinson, Leonora; Rodríguez-Oroz, Maria-Cruz; Obeso, Jose A; Jahanshahi, Marjan

    2013-05-01

    It has been proposed that the subthalamic nucleus (STN) mediates response inhibition and conflict resolution through the fronto-basal ganglia pathways. Our aim was to compare the effects of deep brain stimulation (DBS) of the STN on reactive and proactive inhibition and conflict resolution in Parkinson's disease using a single task. We used the conditional Stop signal reaction time task that provides the Stop signal reaction time (SSRT) as a measure of reactive inhibition, the response delay effect (RDE) as a measure of proactive inhibition and conflict-induced slowing (CIS) as a measure of conflict resolution. DBS of the STN significantly prolonged SSRT relative to stimulation off. However, while the RDE measure of proactive inhibition was not significantly altered by DBS of the STN, relative to healthy controls, RDE was significantly lower with DBS off but not DBS on. DBS of the STN did not alter the mean CIS but produced a significant differential effect on the slowest and fastest RTs on conflict trials, further prolonging the slowest RTs on the conflict trials relative to DBS off and to controls. These results are the first demonstration, using a single task in the same patient sample, that DBS of the STN produces differential effects on reactive and proactive inhibition and on conflict resolution, suggesting that these effects are likely to be mediated through the impact of STN stimulation on different fronto-basal ganglia pathways: hyperdirect, direct and indirect.

  5. Haloperidol 2 mg impairs inhibition but not visuospatial attention.

    PubMed

    Logemann, H N Alexander; Böcker, Koen B E; Deschamps, Peter K H; van Harten, Peter N; Koning, Jeroen; Kemner, Chantal; Logemann-Molnár, Zsófia; Kenemans, J Leon

    2017-01-01

    The dopaminergic system has been implicated in visuospatial attention and inhibition, but the exact role has yet to be elucidated. Scarce literature suggests that attenuation of dopaminergic neurotransmission negatively affects attentional focusing and inhibition. To the best of our knowledge, this is the first study that evaluated the effect of dopaminergic antagonism on stopping performance. Dopaminergic neurotransmission was attenuated in 28 healthy male participants by using 2 mg haloperidol. A repeated-measures placebo-controlled crossover design was implemented, and performance indices of attention and inhibition were assessed in the visual spatial cueing task (VSC) and stop signal task (SST). Additionally, the effect of haloperidol on motoric parameters was assessed. It was expected that haloperidol as contrasted to placebo would result in a reduction of the "validity effect," the benefit of valid cueing as opposed to invalid cueing of a target in terms of reaction time. Furthermore, an increase in stop signal reaction time (SSRT) in the SST was expected. Results partially confirmed the hypothesis. Haloperidol negatively affected inhibitory motor control in the SST as indexed by SSRT, but there were no indications that haloperidol affected bias or disengagement in the VSC task as indicated by a lack of an effect on RTs. Pertaining to secondary parameters, motor activity increased significantly under haloperidol. Haloperidol negatively affected reaction time variability and errors in both tasks, as well as omissions in the SST, indicating a decreased sustained attention, an increase in premature responses, and an increase in lapses of attention, respectively.

  6. The Multifrequency Siberian Radioheliograph

    NASA Astrophysics Data System (ADS)

    Lesovoi, S. V.; Altyntsev, A. T.; Ivanov, E. F.; Gubin, A. V.

    2012-10-01

    The ten-antenna prototype of the multifrequency Siberian radioheliograph is described. The prototype consists of four parts: antennas with broadband front-ends, analog back-ends, digital receivers and a correlator. The prototype antennas are mounted on the outermost stations of the Siberian Solar Radio Telescope (SSRT) array. A signal from each antenna is transmitted to a workroom by an analog fiber optical link, laid in an underground tunnel. After mixing, all signals are digitized and processed by digital receivers before the data are transmitted to the correlator. The digital receivers and the correlator are accessible by the Local Area Network (LAN). The frequency range of the prototype is from 4 to 8 GHz. Currently the frequency switching observing mode is used. The prototype data include both circular polarizations at a number of frequencies given by a list. This prototype is the first stage of the multifrequency Siberian radioheliograph development. It is assumed that the radioheliograph will consist of 96 antennas and will occupy stations of the West-East-South subarray of the SSRT. The radioheliograph will be fully constructed in the autumn of 2012. We plan to reach the brightness temperature sensitivity of about 100 K for the snapshot image, a spatial resolution up to 13 arcseconds at 8 GHz and a polarization measurement accuracy about a few percent. First results with the ten-antenna prototype are presented of observations of solar microwave bursts. The prototype's abilities to estimate source size and locations at different frequencies are discussed.

  7. Integrating impairments in reaction time and executive function using a diffusion model framework

    PubMed Central

    Karalunas, Sarah L.; Huang-Pollock, Cynthia L.

    2013-01-01

    Using Ratcliff’s diffusion model and ex-Gaussian decomposition, we directly evaluate the role individual differences in reaction time (RT) distribution components play in the prediction of inhibitory control and working memory (WM) capacity in children with and without ADHD. Children with (n=92, x̄ age= 10.2 years, 67% male) and without ADHD (n=62, x̄ age=10.6 years, 46% male) completed four tasks of WM and a stop signal reaction time (SSRT) task. Children with ADHD had smaller WM capacities and less efficient inhibitory control. Diffusion model analyses revealed that children with ADHD had slower drift rates (v) and faster non-decision times (Ter), but there were no group differences in boundary separations (a). Similarly, using an ex-Gaussian approach, children with ADHD had larger τ values than non-ADHD controls, but did not differ in µ or σ distribution components. Drift rate mediated the association between ADHD status and performance on both inhibitory control and WM capacity. τ also mediated the ADHD-executive function impairment associations; however, models were a poorer fit to the data. Impaired performance on RT and executive functioning tasks has long been associated with childhood ADHD. Both are believed to be important cognitive mechanisms to the disorder. We demonstrate here that drift rate, or the speed at which information accumulates towards a decision, is able to explain both. PMID:23334775

  8. Impairment of manual but not saccadic response inhibition following acute alcohol intoxication.

    PubMed

    Campbell, Anne Eileen; Chambers, Christopher D; Allen, Christopher P G; Hedge, Craig; Sumner, Petroc

    2017-12-01

    Alcohol impairs response inhibition; however, it remains contested whether such impairments affect a general inhibition system, or whether affected inhibition systems are embedded in, and specific to, each response modality. Further, alcohol-induced impairments have not been disambiguated between proactive and reactive inhibition mechanisms, and nor have the contributions of action-updating impairments to behavioural 'inhibition' deficits been investigated. Forty Participants (25 female) completed both a manual and a saccadic stop-signal reaction time (SSRT) task before and after a 0.8g/kg dose of alcohol and, on a separate day, before and after a placebo. Blocks in which participants were required to ignore the signal to stop or make an additional 'dual' response were included to obtain measures of proactive inhibition as well as updating of attention and action. Alcohol increased manual but not saccadic SSRT. Proactive inhibition was weakly reduced by alcohol, but increases in the reaction times used to baseline this contrast prevent clear conclusions regarding response caution. Finally, alcohol also increased secondary dual response times of the dual task uniformly as a function of the delay between tasks, indicating an effect of alcohol on action-updating or execution. The modality-specific effects of alcohol favour the theory that response inhibition systems are embedded within response modalities, rather than there existing a general inhibition system. Concerning alcohol, saccadic control appears relatively more immune to disruption than manual control, even though alcohol affects saccadic latency and velocity. Within the manual domain, alcohol affects multiple types of action updating, not just inhibition. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Microwave coherent emissions from solar flares - a look at through a large interferometer

    NASA Astrophysics Data System (ADS)

    Altyntsev, Alexandre; Sergei, Lesovoi; Natalia, Meshalkina; Dmitrii, Zhdanov; Natalia, Korolkova

    2013-04-01

    The report discusses the results of microwave observations of coherent emission sources with broadband spectropolarimeters and the Siberian Solar Radio Telescope (receiving frequency about 5.7 GHz). To date, more than 300 events with narrowband subsecond pulses were recorded. It is revealed that at the small real sizes of sources their apparent sizes can reach the SSRT beam width (≥ 15 arcsec) due to electromagnetic wave scattering by density fluctuations in the lower corona, or due to emission reflection from the underlying layers of the solar atmosphere. The fine emission sources usually occur near tops of the flare loops. In some events it was possible to reveal plasma parameters in the vicinity of the fine emission exciters from the X-ray, optical and continuum microwave images, and to identify the mechanisms of the coherent emission. The SSRT is an interferometer that allows to record spatial brightness distributions of a flare region at two close frequencies simultaneously. Such observations have showed that the frequency dynamics of fast drifting narrowband bursts (type III - like) is controlled not only by the velocity of exciter movement through gradients of the plasma parameters, but also by rapid changes in plasma parameters over time. We discuss the diagnostic potential of the observations of coherent emission sources and new possibilities of the instruments which are under construction now. The work is supported by the Ministry of education and science of the Russian Federation (State Contracts 16.518.11.7065 and 02.740.11.0576), and by the grants RFBR (12-02-91161-GFEN-a, 12-02-00616 and 12-02-00173-a

  10. Corrosion and Potentiostatic Polarization of an Al-Cu-Li Alloy under Tensile Stress

    NASA Astrophysics Data System (ADS)

    Li, Jin-feng; Zheng, Zi-qiao

    The stress corrosion cracking (SCC) of an Al-3.8Cu-1.5Li-0.5Zn-0.5Mg-0.3Mn alloy in 3.5% NaCl solution was studied through using slow strain rate tension(SSRT). The potentiodynamic polarization and anodic potentiostastic polarization of the stressed and stress free alloy with T6 temper were investigated. The tensile stress decreased the break down potential. The alloy was sensitive to intergranular SCC (IGSCC), due to the continuous distribution of anodic phase of T2(Al6CuLi3) along the grain boundary. During the potentiostastic polarization, the current-time curve of the stressed alloy displayed a repeated transient feature that the current increased suddenly followed by a slower recovery, and corrosion crack appeared along the grain boundary. While the stress free alloy did not show this current feature and corrosion crack along the grain boundary. The repeated current transient was associated with the crack tip propagation and crack wall passivation. This feature may be used to analyze the SCC process.

  11. Stress corrosion cracking behavior of irradiated model austenitic stainless steel alloys.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, H. M.; Karlsen, T. M.; Ruther, W. E.

    Slow-strain-rate tensile tests (SSRTs) and posttest fractographic analyses by scanning electron microscopy were conducted on 16 austenitic stainless steel (SS) alloys that were irradiated at 289 C in He. After irradiation to {approx}0.3 x 10{sup 21} n{center_dot}cm{sup {minus}2} and {approx}0.9 x 10{sup 21} n{center_dot}cm{sup {minus}2} (E >1 MeV), significant heat-to-heat variations in the degree of intergranular and transgranular stress corrosion cracking (IGSCC and TGSCC) were observed. Following irradiation to a fluence of {approx}0.3 x 10{sup 21} n{center_dot}cm{sup {minus}2}, a high-purity laboratory heat of Type 316L SS (Si {approx} 0.024 wt%) exhibited the highest susceptibility to IGSCC. The other 15 alloysmore » exhibited negligible susceptibility to IGSCC at this low fluence. The percentage of TGSCC on the fracture surfaces of SSRT specimens of the 16 alloys at {approx}0.3 x 10{sup 21} n{center_dot}cm{sup {minus}2} (E > 1 MeV) could be correlated well with N and Si concentrations; all alloys that contained <0.01 wt.% N and <1.0 wt. % Si were susceptible, whereas all alloys that contained >0.01 wt.% N or >1.0 wt.% Si were relatively resistant. High concentrations of Cr were beneficial. Alloys that contain <15.5 wt.% Cr exhibited greater percentages of TGSCC and IGSCC than those alloys with {approx}18 wt.% Cr, whereas an alloy that contains >21 wt.% Cr exhibited less susceptibility than the lower-Cr alloys under similar conditions.« less

  12. SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Obeid, L; Esteve, F; Adam, J

    2014-06-15

    Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0more » and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.« less

  13. The 26 December 2001 Solar Event Responsible for GLE63. I. Observations of a Major Long-Duration Flare with the Siberian Solar Radio Telescope

    NASA Astrophysics Data System (ADS)

    Grechnev, V. V.; Kochanov, A. A.

    2016-12-01

    Ground level enhancements (GLEs) of cosmic-ray intensity occur, on average, once a year. Because they are rare, studying the solar sources of GLEs is especially important to approach understanding their origin. The SOL2001-12-26 eruptive-flare event responsible for GLE63 seems to be challenging in some aspects. Deficient observations limited our understanding of it. Analysis of additional observations found for this event provided new results that shed light on the flare configuration and evolution. This article addresses the observations of this flare with the Siberian Solar Radio Telescope (SSRT). Taking advantage of its instrumental characteristics, we analyze the detailed SSRT observations of a major long-duration flare at 5.7 GHz without cleaning the images. The analysis confirms that the source of GLE63 was associated with an event in active region 9742 that comprised two flares. The first flare (04:30 - 05:03 UT) reached a GOES importance of about M1.6. Two microwave sources were observed, whose brightness temperatures at 5.7 GHz exceeded 10 MK. The main flare, up to an importance of M7.1, started at 05:04 UT and occurred in strong magnetic fields. The observed microwave sources reached a brightness temperature of about 250 MK. They were not static. After appearing on the weaker-field periphery of the active region, the microwave sources moved toward each other nearly along the magnetic neutral line, approaching the stronger-field core of the active region, and then moved away from the neutral line like expanding ribbons. These motions rule out an association of the non-thermal microwave sources with a single flaring loop.

  14. Integrating impairments in reaction time and executive function using a diffusion model framework.

    PubMed

    Karalunas, Sarah L; Huang-Pollock, Cynthia L

    2013-07-01

    Using Ratcliff's diffusion model and ex-Gaussian decomposition, we directly evaluate the role individual differences in reaction time (RT) distribution components play in the prediction of inhibitory control and working memory (WM) capacity in children with and without ADHD. Children with (n = 91, [Formula: see text] age = 10.2 years, 67 % male) and without ADHD (n = 62, [Formula: see text] age = 10.6 years, 46 % male) completed four tasks of WM and a stop signal reaction time (SSRT) task. Children with ADHD had smaller WM capacities and less efficient inhibitory control. Diffusion model analyses revealed that children with ADHD had slower drift rates (v) and faster non-decision times (Ter), but there were no group differences in boundary separations (a). Similarly, using an ex-Gaussian approach, children with ADHD had larger τ values than non-ADHD controls, but did not differ in μ or σ distribution components. Drift rate mediated the association between ADHD status and performance on both inhibitory control and WM capacity. τ also mediated the ADHD-executive function impairment associations; however, models were a poorer fit to the data. Impaired performance on RT and executive functioning tasks has long been associated with childhood ADHD. Both are believed to be important cognitive mechanisms to the disorder. We demonstrate here that drift rate, or the speed at which information accumulates towards a decision, is able to explain both.

  15. Inhibition of ongoing responses in patients with Parkinson's disease

    PubMed Central

    Gauggel, S; Rieger, M; Feghoff, T

    2004-01-01

    Objectives: We investigated the involvement of the basal ganglia in inhibiting ongoing responses in patients with Parkinson's disease (PD). Methods: Thirty two patients with PD and 31 orthopaedic controls performed the stop signal task, which allows an estimation of the time it takes to inhibit an ongoing reaction (stop signal reaction time, SSRT). Results: Patients with PD showed significantly longer SSRTs than the controls. This effect seemed to be independent of global cognitive impairment and severity of PD. Furthermore, in the PD patients, there was no significant relation between general slowing and inhibitory efficiency. Conclusions: Our results provide evidence for involvement of the basal ganglia in the inhibition of ongoing responses. PMID:15026491

  16. A dual but asymmetric role of the dorsal anterior cingulate cortex in response inhibition and switching from a non-salient to salient action

    PubMed Central

    Manza, Peter; Hu, Sien; Chao, Herta H.; Zhang, Sheng; Leung, Hoi-Chung; Li, Chiang-shan R.

    2016-01-01

    Response inhibition and salience detection are among the most studied psychological constructs of cognitive control. Despite a growing body of work, how inhibition and salience processing interact and engage regional brain activations remains unclear. Here, we examined this issue in a stop signal task (SST), where a prepotent response needs to be inhibited to allow an alternative, less dominant response. Sixteen adult individuals performed two versions of the SST each with 25% (SST25) and 75% (SST75) of stop trials. We posited that greater regional activations to the infrequent trial type in each condition (i.e., to stop as compared to go trials in SST25 and to go as compared to stop trials in SST75) support salience detection. Further, successful inhibition in stop trials requires attention to the stop signal to trigger motor inhibition, and the stop signal reaction time (SSRT) has been used to index the efficiency of motor response inhibition. Therefore, greater regional activations to stop as compared to go success trials in association with the stop signal reaction time (SSRT) serves to expedite response inhibition. In support of an interactive role, the dorsal anterior cingulate cortex (dACC) increases activation to salience detection in both SST25 and SST75, but only mediates response inhibition in SST75. Thus, infrequency response in the dACC supports motor inhibition only when stopping has become a routine. In contrast, although the evidence is less robust, the pre-supplementary motor area (pre-SMA) increases activity to the infrequent stimulus and supports inhibition in both SST25 and SST75. These findings clarify a unique role of the dACC and add to the literature that distinguishes dACC and pre-SMA functions in cognitive control. PMID:27126003

  17. A dual but asymmetric role of the dorsal anterior cingulate cortex in response inhibition and switching from a non-salient to salient action.

    PubMed

    Manza, Peter; Hu, Sien; Chao, Herta H; Zhang, Sheng; Leung, Hoi-Chung; Li, Chiang-Shan R

    2016-07-01

    Response inhibition and salience detection are among the most studied psychological constructs of cognitive control. Despite a growing body of work, how inhibition and salience processing interact and engage regional brain activations remains unclear. Here, we examined this issue in a stop signal task (SST), where a prepotent response needs to be inhibited to allow an alternative, less dominant response. Sixteen adult individuals performed two versions of the SST each with 25% (SST25) and 75% (SST75) of stop trials. We posited that greater regional activations to the infrequent trial type in each condition (i.e., to stop as compared to go trials in SST25 and to go as compared to stop trials in SST75) support salience detection. Further, successful inhibition in stop trials requires attention to the stop signal to trigger motor inhibition, and the stop signal reaction time (SSRT) has been used to index the efficiency of motor response inhibition. Therefore, greater regional activations to stop as compared to go success trials in association with the stop signal reaction time (SSRT) serve to expedite response inhibition. In support of an interactive role, the dorsal anterior cingulate cortex (dACC) increases activation to salience detection in both SST25 and SST75, but only mediates response inhibition in SST75. Thus, infrequency response in the dACC supports motor inhibition only when stopping has become a routine. In contrast, although the evidence is less robust, the pre-supplementary motor area (pre-SMA) increases activity to the infrequent stimulus and supports inhibition in both SST25 and SST75. These findings clarify a unique role of the dACC and add to the literature that distinguishes dACC and pre-SMA functions in cognitive control. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Tailoring the Kinetics of the Photoinitiated Cationic Polymerization of Polyoctahedral Oligomeric Silsesquioxane (POSS)-Containing Epoxy Monomers

    NASA Astrophysics Data System (ADS)

    Iordanov, Liubomir

    Within the aircraft industry, high strength steels have been used for aircraft components (e.g., main landing gear, fasteners, etc). These steels have traditionally been protected using cadmium electroplating. As a result of the carcinogenic nature of cadmium, its use has been severely restricted. Electroplated ZnNi has been identified as a replacement material for the cadmium coating. Demonstration plating lines have been implemented in both Air Force and NAVAIR depots. However, the effects of hydrogen generated from differences in electrochemical potential between the ZnNi coating and exposed steel at a defect site have raised concern. The objective of this work is to determine the potential effect of hydrogen on the susceptibility of ZnNi coated 4340 steel to Hydrogen Embrittlement. In this work, susceptibility of the substrate AISI 4340 steel to HE as a function of cathodic potential will be shown. Slow strain rate tests (SSRT) of smooth bar samples made of high strength AISI 4340 are being conducted to determine susceptibility to HE. In the first set of SSR experiments, bare steel samples were exposed to a NaCl immersion environment while being held at one of five different electrochemical potentials. The effect of potential on time to failure and other properties will be explored. A second set of SSR tests were performed under atmospheric exposure conditions at 84% RH. This value of RH is above the deliquescence point of NaCl and was controlled within the enclosed SSR test cell using a saturated solution of Sodium Sulfate at the bottom of the cell. NaCl salt was deposited on the SSR sample gauge section by a salt spray technique. Filter paper soaked in saturated NaCl solution was used to act as a salt bridge for the reference and counter electrodes under atmospheric condition. The effect of electrochemical potential on the cracking behavior of the atmospherically exposed samples will also be described. SEM characterization of the fractured samples was performed to validate embrittlement. Results from this effort will be used by both the Air Force and Navy to assess the need for enhanced risk based inspection of ZnNi coated steel parts. Engineering modeling was done for different defect sizes on the sample and results were used to validate engineering modeling approaches to predict corrosion and cracking performance during system design.

  19. Irradiation-assisted stress corrosion cracking of model austenitic stainless steel.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, H. M.; Ruther, W. E.; Strain, R. V.

    1999-10-26

    Slow-strain-rate tensile (SSRT) tests were conducted on model austenitic stainless steel (SS) alloys that were irradiated at 289 C in He. After irradiation to {approx}0.3 x 10{sup 21} n {center_dot} cm{sup 2} and {approx} 0.9 x 10{sup 21} n {center_dot} cm{sup -2} (E > 1 MeV), significant heat-to-heat variations in the degree of intergranular and transgranular stress corrosion cracking (IGSCC and TGSCC) were observed. At {approx}0.3 x 10{sup 21} n {center_dot} cm{sup -2}, a high-purity heat of Type 316L SS that contains a very low concentration of Si exhibited the highest susceptibility to IGSCC. In unirradiated state, Types 304 andmore » 304L SS did not exhibit a systematic effect of Si content on alloy strength. However, at {approx}0.3 x 10{sup 21} n {center_dot} cm{sup -2}, yield and maximum strengths decreased significantly as Si content was increased to >0.9 wt.%. Among alloys that contain low concentrations of C and N, ductility and resistance to TGSCC and IGSCC were significantly greater for alloys with >0.9 wt.% Si than for alloys with <0.47 wt.% Si. Initial data at {approx}0.9 x 10{sup 21} n {center_dot} cm{sup -2} were also consistent with the beneficial effect of high Si content. This indicates that to delay onset of and reduce susceptibility to irradiation-assisted stress corrosion cracking (IASCC), at least at low fluence levels, it is helpful to ensure a certain minimum concentration of Si. High concentrations of Cr were also beneficial; alloys that contain <15.5 wt.% Cr exhibited greater susceptibility to IASCC than alloys with {approx}18 wt.% Cr, whereas an alloy that contains >21 wt.% Cr exhibited less susceptibility than the lower-Cr alloys under similar conditions.« less

  20. Executive Functioning in Highly Talented Soccer Players

    PubMed Central

    Verburgh, Lot; Scherder, Erik J. A.; van Lange, Paul A.M.; Oosterlaan, Jaap

    2014-01-01

    Executive functions might be important for successful performance in sports, particularly in team sports requiring quick anticipation and adaptation to continuously changing situations in the field. The executive functions motor inhibition, attention and visuospatial working memory were examined in highly talented soccer players. Eighty-four highly talented youth soccer players (mean age 11.9), and forty-two age-matched amateur soccer players (mean age 11.8) in the age range 8 to 16 years performed a Stop Signal task (motor inhibition), the Attention Network Test (alerting, orienting, and executive attention) and a visuospatial working memory task. The highly talented soccer players followed the talent development program of the youth academy of a professional soccer club and played at the highest national soccer competition for their age. The amateur soccer players played at a regular soccer club in the same geographical region as the highly talented soccer players and play in a regular regional soccer competition. Group differences were tested using analyses of variance. The highly talented group showed superior motor inhibition as measured by stop signal reaction time (SSRT) on the Stop Signal task and a larger alerting effect on the Attention Network Test, indicating an enhanced ability to attain and maintain an alert state. No group differences were found for orienting and executive attention and visuospatial working memory. A logistic regression model with group (highly talented or amateur) as dependent variable and executive function measures that significantly distinguished between groups as predictors showed that these measures differentiated highly talented soccer players from amateur soccer players with 89% accuracy. Highly talented youth soccer players outperform youth amateur players on suppressing ongoing motor responses and on the ability to attain and maintain an alert state; both may be essential for success in soccer. PMID:24632735

  1. Stop feeling: inhibition of emotional interference following stop-signal trials.

    PubMed

    Kalanthroff, Eyal; Cohen, Noga; Henik, Avishai

    2013-01-01

    Although a great deal of literature has been dedicated to the mutual links between emotion and the selective attention component of executive control, there is very little data regarding the links between emotion and the inhibitory component of executive control. In the current study we employed an emotional stop-signal task in order to examine whether emotion modulates and is modulated by inhibitory control. Results replicated previous findings showing reduced inhibitory control [longer stop-signal reaction time (SSRT)] following negative, compared to neutral pictures. Most importantly, results show decreased emotional interference following stop-signal trials. These results show that the inhibitory control component of executive control can serve to decrease emotional effects. We suggest that inhibitory control and emotion have a two-way connection in which emotion disrupts inhibitory control and activation of inhibitory control disrupts emotion.

  2. General and food-specific inhibitory deficits in binge eating disorder.

    PubMed

    Svaldi, Jennifer; Naumann, Eva; Trentowska, Monika; Schmitz, Florian

    2014-07-01

    To investigate behavioral inhibition in individuals with binge eating disorder (BED) compared with overweight and obese individuals without BED (No-BED). Participants with BED (n = 31) and the weight-matched No-BED group (n = 29) completed an inhibitory control task (stop-signal task, SST) with food and neutral stimuli. The BED group needed more time to stop an ongoing response, as indicated by increased stop signal reaction time (SSRT) relative to the No-BED group. Additionally, compared with the No-BED group, the BED group displayed more difficulty inhibiting responses elicited by food stimuli. The deficits in behavioral response inhibition were also found to be related to the severity of reported symptoms. There is a general deficit in late stage behavioral inhibition in BED, and this may be particularly pronounced in the context of food stimuli. © 2014 Wiley Periodicals, Inc.

  3. Multiscale modelling and experimentation of hydrogen embrittlement in aerospace materials

    NASA Astrophysics Data System (ADS)

    Jothi, Sathiskumar

    Pulse plated nickel and nickel based superalloys have been used extensively in the Ariane 5 space launcher engines. Large structural Ariane 5 space launcher engine components such as combustion chambers with complex microstructures have usually been manufactured using electrodeposited nickel with advanced pulse plating techniques with smaller parts made of nickel based superalloys joined or welded to the structure to fabricate Ariane 5 space launcher engines. One of the major challenges in manufacturing these space launcher components using newly developed materials is a fundamental understanding of how different materials and microstructures react with hydrogen during welding which can lead to hydrogen induced cracking. The main objective of this research has been to examine and interpret the effects of microstructure on hydrogen diffusion and hydrogen embrittlement in (i) nickel based superalloy 718, (ii) established and (iii) newly developed grades of pulse plated nickel used in the Ariane 5 space launcher engine combustion chamber. Also, the effect of microstructures on hydrogen induced hot and cold cracking and weldability of three different grades of pulse plated nickel were investigated. Multiscale modelling and experimental methods have been used throughout. The effect of microstructure on hydrogen embrittlement was explored using an original multiscale numerical model (exploiting synthetic and real microstructures) and a wide range of material characterization techniques including scanning electron microscopy, 2D and 3D electron back scattering diffraction, in-situ and ex-situ hydrogen charged slow strain rate tests, thermal spectroscopy analysis and the Varestraint weldability test. This research shows that combined multiscale modelling and experimentation is required for a fundamental understanding of microstructural effects in hydrogen embrittlement in these materials. Methods to control the susceptibility to hydrogen induced hot and cold cracking and to improve the resistance to hydrogen embrittlement in aerospace materials are also suggested. This knowledge can play an important role in the development of new hydrogen embrittlement resistant materials. A novel micro/macro-scale coupled finite element method incorporating multi-scale experimental data is presented with which it is possible to perform full scale component analyses in order to investigate hydrogen embrittlement at the design stage. Finally, some preliminary and very encouraging results of grain boundary engineering based techniques to develop alloys that are resistant to hydrogen induced failure are presented. Keywords: Hydrogen embrittlement; Aerospace materials; Ariane 5 combustion chamber; Pulse plated nickel; Nickel based super alloy 718; SSRT test; Weldability test; TDA; SEM/EBSD; Hydrogen induced hot and cold cracking; Multiscale modelling and experimental methods.

  4. Corrosion of Advanced Steels: Challenges in the Oil and Gas Industry

    NASA Astrophysics Data System (ADS)

    Mishra, Brajendra; Apelian, Diran

    Drill pipe steels are in contact with CO2 and H2S environments, depending on the oil and gas field. These steels have to be resistant to various in-service conditions including aggressive environments containing CO2, H2S, O2, and chlorides, in addition to static and dynamic mechanical stresses. In this respect stress corrosion cracking susceptibility of two grades of drill pipe steel in CO2 environment have been studied simulating the bottom hole oil and gas well conditions. SSRT results show that SCC susceptibility or loss of ductility changes with temperature and increasing temperature increases the loss of ductility. No FeCO3 is observed below 100 °C, and density of FeCO3 is higher in grip section than gauge length and this is due to strain disturbance of growth of iron carbonate crystals. Material selection for down hole in CO2 containing environments needs has been reviewed and probability of SCC occurrence in higher temperatures has been included.

  5. Inhibitory Control in the Cortico-Basal Ganglia-Thalamocortical Loop: Complex Regulation and Interplay with Memory and Decision Processes.

    PubMed

    Wei, Wei; Wang, Xiao-Jing

    2016-12-07

    We developed a circuit model of spiking neurons that includes multiple pathways in the basal ganglia (BG) and is endowed with feedback mechanisms at three levels: cortical microcircuit, corticothalamic loop, and cortico-BG-thalamocortical system. We focused on executive control in a stop signal task, which is known to depend on BG across species. The model reproduces a range of experimental observations and shows that the newly discovered feedback projection from external globus pallidus to striatum is crucial for inhibitory control. Moreover, stopping process is enhanced by the cortico-subcortical reverberatory dynamics underlying persistent activity, establishing interdependence between working memory and inhibitory control. Surprisingly, the stop signal reaction time (SSRT) can be adjusted by weights of certain connections but is insensitive to other connections in this complex circuit, suggesting novel circuit-based intervention for inhibitory control deficits associated with mental illness. Our model provides a unified framework for inhibitory control, decision making, and working memory. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Retrieval-practice task affects relationship between working memory capacity and retrieval-induced forgetting.

    PubMed

    Storm, Benjamin C; Bui, Dung C

    2016-11-01

    Retrieving a subset of items from memory can cause forgetting of other items in memory, a phenomenon referred to as retrieval-induced forgetting (RIF). Individuals who exhibit greater amounts of RIF have been shown to also exhibit superior working memory capacity (WMC) and faster stop-signal reaction times (SSRTs), results which have been interpreted as suggesting that RIF reflects an inhibitory process that is mediated by the processes of executive control. Across four experiments, we sought to further elucidate this issue by manipulating the way in which participants retrieved items during retrieval practice and examining how the resulting effects of forgetting correlated with WMC (Experiments 1-3) and SSRT (Experiment 4). Significant correlations were observed when participants retrieved items from an earlier study phase (within-list retrieval practice), but not when participants generated items from semantic memory (extra-list retrieval practice). These results provide important new insight into the role of executive-control processes in RIF.

  7. Neurocognitive dysfunction and pharmacological intervention using guanfacine in a rhesus macaque model of self-injurious behavior

    PubMed Central

    Freeman, Z T; Rice, K A; Soto, P L; Pate, K A M; Weed, M R; Ator, N A; DeLeon, I G; Wong, D F; Zhou, Y; Mankowski, J L; Zink, M C; Adams, R J; Hutchinson, E K

    2015-01-01

    Self-injurious behavior (SIB) is a common comorbidity of psychiatric disorders but there is a dearth of information about neurological mechanisms underlying the behavior, and few animal models exist. SIB in humans is characterized by any intentional self-directed behavior that leads to wounds, whereas in macaques it is not always accompanied by wounds. We describe a cohort of rhesus macaques displaying SIB as adults, in which changes within the central nervous system were associated with the SIB. In these macaques, increases in central nervous system striatal dopamine (DA) receptor binding (BPND) measured by positron emission tomography (PET) [11C]raclopride imaging correlated with severity of wounding (rs=0.662, P=0.014). Furthermore, utilizing standardized cognitive function tests, we showed that impulsivity (stop signal reaction time, SSRT) and deficits in attentional set shifting (intra-/extradimensional shift) were correlated with increased severity of SIB (rs=0.563, P=0.045 and rs=0.692, P=0.009, respectively). We also tested the efficacy of guanfacine, an α2A adrenergic agonist that acts to improve postsynaptic transmission of neuronal impulses, in reducing SIB. A subset of these animals were enrolled in a randomized experimenter-blinded study that demonstrated guanfacine decreased the severity of wounding in treated animals compared with vehicle-only-treated controls (P=0.043), with residual beneficial effects seen for several weeks after cessation of therapy. Animals with the highest severity of SIB that received guanfacine also showed the most significant improvement (rs=−0.761, P=0.009). The elevated PET BPND was likely due to low intrasynaptic DA, which in turn may have been improved by guanfacine. With underlying physiology potentially representative of the human condition and the ability to affect outcome measures of disease using pharmacotherapy, this model represents a unique opportunity to further our understanding of the biology and treatment of SIB in both animals and humans. PMID:25989141

  8. Neurocognitive dysfunction and pharmacological intervention using guanfacine in a rhesus macaque model of self-injurious behavior.

    PubMed

    Freeman, Z T; Rice, K A; Soto, P L; Pate, K A M; Weed, M R; Ator, N A; DeLeon, I G; Wong, D F; Zhou, Y; Mankowski, J L; Zink, M C; Adams, R J; Hutchinson, E K

    2015-05-19

    Self-injurious behavior (SIB) is a common comorbidity of psychiatric disorders but there is a dearth of information about neurological mechanisms underlying the behavior, and few animal models exist. SIB in humans is characterized by any intentional self-directed behavior that leads to wounds, whereas in macaques it is not always accompanied by wounds. We describe a cohort of rhesus macaques displaying SIB as adults, in which changes within the central nervous system were associated with the SIB. In these macaques, increases in central nervous system striatal dopamine (DA) receptor binding (BPND) measured by positron emission tomography (PET) [11C]raclopride imaging correlated with severity of wounding (rs=0.662, P=0.014). Furthermore, utilizing standardized cognitive function tests, we showed that impulsivity (stop signal reaction time, SSRT) and deficits in attentional set shifting (intra-/extradimensional shift) were correlated with increased severity of SIB (rs=0.563, P=0.045 and rs=0.692, P=0.009, respectively). We also tested the efficacy of guanfacine, an α2A adrenergic agonist that acts to improve postsynaptic transmission of neuronal impulses, in reducing SIB. A subset of these animals were enrolled in a randomized experimenter-blinded study that demonstrated guanfacine decreased the severity of wounding in treated animals compared with vehicle-only-treated controls (P=0.043), with residual beneficial effects seen for several weeks after cessation of therapy. Animals with the highest severity of SIB that received guanfacine also showed the most significant improvement (rs=-0.761, P=0.009). The elevated PET BPND was likely due to low intrasynaptic DA, which in turn may have been improved by guanfacine. With underlying physiology potentially representative of the human condition and the ability to affect outcome measures of disease using pharmacotherapy, this model represents a unique opportunity to further our understanding of the biology and treatment of SIB in both animals and humans.

  9. Microdomain Yield Behaviour in an Ultra-High Strength Low Alloy Steel for Marine Use with Low Sensitivity of SCC

    NASA Astrophysics Data System (ADS)

    Yin, Jiang; Tao, Anxiang; Xu, Pingguang; Ping, Dehai

    The present paper involves a fundamental research on microdomain yield behavior of an ultrahigh strength low alloy steel with high temperature tempered bainite. The smooth cylinder specimen was took from deep water mooring chain links from the steel with the chemical composition of 0.23C-0.25Si -0.70Mn-3.55 (Cr+Ni+Mo) -0.13 (V+Nb+Ti) (mass %) ,which was quenched from 1253K and then tempered at 873K Its macroscopic yield strength is 1120MPa and the tensile strength is 1250MPa In-situ neutron diffraction measurements of loading tension have suggested that a good linear elastic deformation can be kept up to 500MPa stress, and then (200) priority non-linear elastic strain, that is the yield of crystal lattice occur at 700MPa and the (110) non-linear elastic strain was found at 800MPa. The (200) and (110) nonlinear elastic strain increases gradually when the stress was further increased, however, the (211) kept its linear elastic deformation stage as before. The sub-microstructural analysis carried out using TEM and additional determine the nature and quantitative analysis has revealed that there are three kinds of alloy carbides: (1) θ-M3C cementites with an average particle size of less than 50 nm which inside laths and lath boundaries; (2) ɛ-M2C formed uniformly within the ferrites with a length of less than 200 nm and width of less than 20 nm; (3) ultra-fine high density MC cohered with matrix α-Fe and its particle size is about 2 nm. The whole microdomain yield behaviour of the material was possibly influenced by the fcc-MC with high density. The results of CLT (constant load), SSRT (slow strain rate) and KIscc test of the present chain in seawater solution indicate, that threshold value of SCC (stress corrosion cracking) stress exceed 0.8 tensile strength and the chain's KIscc value is double of KIscc value of 4340 steel type parts. MC not only form strong hydrogen trap, but also slow down microdomain yield likely by means of increasing yield strength of crystal lattice, thus reduce SCC sensibility of the steel.

  10. Validated univariate and multivariate spectrophotometric methods for the determination of pharmaceuticals mixture in complex wastewater

    NASA Astrophysics Data System (ADS)

    Riad, Safaa M.; Salem, Hesham; Elbalkiny, Heba T.; Khattab, Fatma I.

    2015-04-01

    Five, accurate, precise, and sensitive univariate and multivariate spectrophotometric methods were developed for the simultaneous determination of a ternary mixture containing Trimethoprim (TMP), Sulphamethoxazole (SMZ) and Oxytetracycline (OTC) in waste water samples collected from different cites either production wastewater or livestock wastewater after their solid phase extraction using OASIS HLB cartridges. In univariate methods OTC was determined at its λmax 355.7 nm (0D), while (TMP) and (SMZ) were determined by three different univariate methods. Method (A) is based on successive spectrophotometric resolution technique (SSRT). The technique starts with the ratio subtraction method followed by ratio difference method for determination of TMP and SMZ. Method (B) is successive derivative ratio technique (SDR). Method (C) is mean centering of the ratio spectra (MCR). The developed multivariate methods are principle component regression (PCR) and partial least squares (PLS). The specificity of the developed methods is investigated by analyzing laboratory prepared mixtures containing different ratios of the three drugs. The obtained results are statistically compared with those obtained by the official methods, showing no significant difference with respect to accuracy and precision at p = 0.05.

  11. Validated univariate and multivariate spectrophotometric methods for the determination of pharmaceuticals mixture in complex wastewater.

    PubMed

    Riad, Safaa M; Salem, Hesham; Elbalkiny, Heba T; Khattab, Fatma I

    2015-04-05

    Five, accurate, precise, and sensitive univariate and multivariate spectrophotometric methods were developed for the simultaneous determination of a ternary mixture containing Trimethoprim (TMP), Sulphamethoxazole (SMZ) and Oxytetracycline (OTC) in waste water samples collected from different cites either production wastewater or livestock wastewater after their solid phase extraction using OASIS HLB cartridges. In univariate methods OTC was determined at its λmax 355.7 nm (0D), while (TMP) and (SMZ) were determined by three different univariate methods. Method (A) is based on successive spectrophotometric resolution technique (SSRT). The technique starts with the ratio subtraction method followed by ratio difference method for determination of TMP and SMZ. Method (B) is successive derivative ratio technique (SDR). Method (C) is mean centering of the ratio spectra (MCR). The developed multivariate methods are principle component regression (PCR) and partial least squares (PLS). The specificity of the developed methods is investigated by analyzing laboratory prepared mixtures containing different ratios of the three drugs. The obtained results are statistically compared with those obtained by the official methods, showing no significant difference with respect to accuracy and precision at p=0.05. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Investigation of in-vehicle speech intelligibility metrics for normal hearing and hearing impaired listeners

    NASA Astrophysics Data System (ADS)

    Samardzic, Nikolina

    The effectiveness of in-vehicle speech communication can be a good indicator of the perception of the overall vehicle quality and customer satisfaction. Currently available speech intelligibility metrics do not account in their procedures for essential parameters needed for a complete and accurate evaluation of in-vehicle speech intelligibility. These include the directivity and the distance of the talker with respect to the listener, binaural listening, hearing profile of the listener, vocal effort, and multisensory hearing. In the first part of this research the effectiveness of in-vehicle application of these metrics is investigated in a series of studies to reveal their shortcomings, including a wide range of scores resulting from each of the metrics for a given measurement configuration and vehicle operating condition. In addition, the nature of a possible correlation between the scores obtained from each metric is unknown. The metrics and the subjective perception of speech intelligibility using, for example, the same speech material have not been compared in literature. As a result, in the second part of this research, an alternative method for speech intelligibility evaluation is proposed for use in the automotive industry by utilizing a virtual reality driving environment for ultimately setting targets, including the associated statistical variability, for future in-vehicle speech intelligibility evaluation. The Speech Intelligibility Index (SII) was evaluated at the sentence Speech Receptions Threshold (sSRT) for various listening situations and hearing profiles using acoustic perception jury testing and a variety of talker and listener configurations and background noise. In addition, the effect of individual sources and transfer paths of sound in an operating vehicle to the vehicle interior sound, specifically their effect on speech intelligibility was quantified, in the framework of the newly developed speech intelligibility evaluation method. Lastly, as an example of the significance of speech intelligibility evaluation in the context of an applicable listening environment, as indicated in this research, it was found that the jury test participants required on average an approximate 3 dB increase in sound pressure level of speech material while driving and listening compared to when just listening, for an equivalent speech intelligibility performance and the same listening task.

  13. Single Stage Rocket Technology's real time data system

    NASA Technical Reports Server (NTRS)

    Voglewede, Steven D.

    1994-01-01

    The Single Stage Rocket Technology (SSRT) Delta Clipper Experimental (DC-X) Program is a United States Air Force Ballistic Missile Defense Organization (BMDO) rapid prototyping initiative that is currently demonstrating technology readiness for reusable suborbital rockets. The McDonnell Douglas DC-X rocket performed technology demonstrations at the U.S. Army White Sands Missile Range in New Mexico from April-October in 1993. The DC-X Flight Operations Control Center (FOCC) contains the ground control system that is used to monitor and control the DC-X vehicle and its Ground Support Systems (GSS). The FOCC is operated by a flight crew of three operators. Two operators manage the DC-X Flight Systems and one operator is the Ground Systems Manager. A group from McDonnell Douglas Aerospace at KSC developed the DC-X ground control system for the FOCC. This system is known as the Real Time Data System (RTDS). The RTDS is a distributed real time control and monitoring system that utilizes the latest available commercial off-the-shelf computer technology. The RTDS contains front end interfaces for the DC-X RF uplink/downlink and fiber optic interfaces to the GSS equipment. This paper describes the RTDS architecture and FOCC layout. The DC-X applications and ground operations are covered.

  14. Beamlines of the Biomedical Imaging and Therapy Facility at the Canadian Light Source - Part 2

    NASA Astrophysics Data System (ADS)

    Wysokinski, T. W.; Chapman, D.; Adams, G.; Renier, M.; Suortti, P.; Thomlinson, W.

    2013-03-01

    The BioMedical Imaging and Therapy (BMIT) facility provides a world class facility with unique synchrotron-specific imaging and therapy capabilities. This paper describes Insertion Device (ID) beamline 05ID-2 with the beam terminated in the first experimental hutch: POE-2. The experimental methods available in POE-2 include: Microbeam Radiation Therapy (MRT), Synchrotron Stereotactic Radiation Therapy (SSRT) and absorption imaging (projection and Computed Tomography (CT)). The source for the ID beamline is a multi-pole superconductive 4.3 T wiggler, which can generate ~30 kW of radiative power and deliver dose as high as 3000 Gy/s required for MRT program. The optics in POE-1 hutch prepares either monochromatic or filtered white beam that is used in POE-2. The Double Crystal (DC), bent Laue monochromator will prepare a beam over 10 cm wide at sample point, while spanning an energy range appropriate for imaging studies of animals (20-100+ keV). The experimental hutch will have a flexible positioning system that can handle subjects up to 120 kg. Several different cameras will be available with resolutions ranging from 4 μm to 150 μm. The latest update on the status of 05B1-1 bending magnet (BM) beamline, described in Part 1 [1], is also included.

  15. Gunslingers, poker players, and chickens 2: Decision-making under physical performance pressure in subelite athletes.

    PubMed

    Parkin, Beth L; Walsh, Vincent

    2017-01-01

    Having investigated the influence of acute physical exhaustion on decision-making in world-class elite athletes in Parkin et al. (2017), here a similar method is applied to subelite athletes. These subelite athletes were enrolled on a Team GB talent development program and were undergoing training for possible Olympic competition in 4-8 years. They differ from elite athletes examined previously according to expertise and age. While considered elite (Swann et al., 2015), the subelite athletes had approximately 8 years fewer sporting experience and were yet to obtain sustained success on the international stage. Additionally, the average age of the subelite sample is 20 years; thus, they are still undergoing the behavioral, cognitive, and neuronal changes that occur during the transition from late adolescence to young adulthood (Blakemore and Robbins, 2012). Previous work has used broad definitions of elite status in sport, and as such overlooked different categories within the spectrum of elite athletes (Swann et al., 2015). Therefore it is important to consider subelite athletes as a discrete point on the developmental trajectory of elite sporting expertise. This work aims to investigate the influence of physical pressure on key indicators of decision-making in subelite athletes. It forms part of a wider project examining decision-making across different stages of the developmental trajectory in elite sport. In doing so, it aims to examine how to apply and develop psychological insights useful to an elite sporting environment. 32 subelite athletes (18 males, mean age: 20 years) participated in the study. Performance across three categories of decision-making was assessed under conditions of low and high physical pressure. Decision-making under risk was measured with performance of the Cambridge Gambling Task (CGT; Rogers et al., 1999), decision-making under uncertainty with the Balloon Analogue Risk Task (BART; Lejuez et al., 2002), and fast reactive responses and inhibition via the Stop Signal Reaction Time Task (SSRT; Logan, 1994). Physical exhaustion was induced via intervals of maximal exertion exercise on a wattbike. Under pressure subelite athletes showed increased risk taking for both decisions where probability outcomes were explicit (on the CGT), and those where probability outcomes were unknown (on the BART). Despite making quicker decisions under pressure, with fewer errors, on the CGT, subelite athletes showed a reduced ability to optimally adjust betting behavior according to reward and loss contingencies. Fast reactive responses to perceptual stimuli and response inhibition did not change as a result of physical pressure. Individual responses to pressure showed a negative correlation in that a decrease in reaction times on the SSRT Task under pressure was associated with an increase in risk taking on the BART. When assessing the applicability of results based on group averages to individual athletes, 17% of the sample showed an "average" response (within 1 SD of the mean) to pressure across all three decision-making tasks. Indicators of decision-making in a sample of subelite athletes are influenced by physical pressure, with a shift toward increased indiscriminate risk taking. The influence that physical pressure has on decision-making was different to that observed in world-class elite athletes; this highlights the importance of distinguishing between athletes at the elite level (Swann et al., 2015). The application of this work to a novel subgroup of elite athletes, including the implementation of a decision-making taxonomy, is discussed. © 2017 Elsevier B.V. All rights reserved.

  16. A COLD FLARE WITH DELAYED HEATING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleishman, Gregory D.; Pal'shin, Valentin D.; Lysenko, Alexandra L.

    2016-05-10

    Recently, a number of peculiar flares have been reported that demonstrate significant nonthermal particle signatures with low, if any, thermal emission, which implies a close association of the observed emission with the primary energy release/electron acceleration region. This paper presents a flare that appears “cold” at the impulsive phase, while displaying delayed heating later on. Using hard X-ray data from Konus- Wind , microwave observations by SSRT, RSTN, NoRH, and NoRP, context observations, and three-dimensional modeling, we study the energy release, particle acceleration, and transport, and the relationships between the nonthermal and thermal signatures. The flaring process is found tomore » involve the interaction between a small loop and a big loop with the accelerated particles divided roughly equally between them. Precipitation of the electrons from the small loop produced only a weak thermal response because the loop volume was small, while the electrons trapped in the big loop lost most of their energy in the coronal part of the loop, which resulted in coronal plasma heating but no or only weak chromospheric evaporation, and thus unusually weak soft X-ray emission. The energy losses of the fast electrons in the big tenuous loop were slow, which resulted in the observed delay of the plasma heating. We determined that the impulsively accelerated electron population had a beamed angular distribution in the direction of the electric force along the magnetic field of the small loop. The accelerated particle transport in the big loop was primarily mediated by turbulent waves, which is similar to other reported cold flares.« less

  17. Family history of alcoholism interacts with alcohol to affect brain regions involved in behavioral inhibition

    PubMed Central

    Kareken, David A.; Dzemidzic, Mario; Wetherill, Leah; Eiler, William; Oberlin, Brandon G.; Harezlak, Jaroslaw; Wang, Yang; O’Connor, Sean J.

    2013-01-01

    Rationale Impulsive behavior is associated with both alcohol use disorders and a family history of alcoholism (FHA). One operational definition of impulsive behavior is the stop signal task (SST), which measures the time needed to stop a ballistic hand movement. Objective Employ functional magnetic resonance imaging (fMRI) to study right frontal responses to stop signals in heavy drinking subjects with and without FHA, and as a function of alcohol exposure. Methods Twenty two family history positive (FHP; age = 22.7 years, SD= 1.9) and 18 family history negative (FHN; age = 23.7, SD= 1.8) subjects performed the SST in fMRI in two randomized visits: once during intravenous infusion of alcohol, clamped at a steady-state breath alcohol (BrAC) concentration of 60mg%, and once during infusion of placebo saline. An independent reference group (n= 13, age= 23.7, SD= 1.8) was used to identify a priori right prefrontal regions activated by successful inhibition (Inh) trials, relative to ‘Go’ trials that carried no need for inhibition (Inh > Go). Results FHA interacted with alcohol exposure in right prefrontal cortex, where alcohol reduced [Inh > Go] activation in FHN subjects, but not in FHP subjects. Within this right frontal cortical region, stop signal reaction time (SSRT) also correlated negatively with [Inh > Go] activation, suggesting that the [Inh > Go] activity was related to inhibitory behavior. Conclusions The results are consistent with the low level of response theory (Schuckit, 1980; Quinn & Fromme, 2011), with FHP being less sensitive to alcohol’s effects. PMID:23468100

  18. Countermanding eye-head gaze shifts in humans: marching orders are delivered to the head first.

    PubMed

    Corneil, Brian D; Elsley, James K

    2005-07-01

    The countermanding task requires subjects to cancel a planned movement on appearance of a stop signal, providing insights into response generation and suppression. Here, we studied human eye-head gaze shifts in a countermanding task with targets located beyond the horizontal oculomotor range. Consistent with head-restrained saccadic countermanding studies, the proportion of gaze shifts on stop trials increased the longer the stop signal was delayed after target presentation, and gaze shift stop-signal reaction times (SSRTs: a derived statistic measuring how long it takes to cancel a movement) averaged approximately 120 ms across seven subjects. We also observed a marked proportion of trials (13% of all stop trials) during which gaze remained stable but the head moved toward the target. Such head movements were more common at intermediate stop signal delays. We never observed the converse sequence wherein gaze moved while the head remained stable. SSRTs for head movements averaged approximately 190 ms or approximately 70-75 ms longer than gaze SSRTs. Although our findings are inconsistent with a single race to threshold as proposed for controlling saccadic eye movements, movement parameters on stop trials attested to interactions consistent with a race model architecture. To explain our data, we tested two extensions to the saccadic race model. The first assumed that gaze shifts and head movements are controlled by parallel but independent races. The second model assumed that gaze shifts and head movements are controlled by a single race, preceded by terminal ballistic intervals not under inhibitory control, and that the head-movement branch is activated at a lower threshold. Although simulations of both models produced acceptable fits to the empirical data, we favor the second alternative as it is more parsimonious with recent findings in the oculomotor system. Using the second model, estimates for gaze and head ballistic intervals were approximately 25 and 90 ms, respectively, consistent with the known physiology of the final motor paths. Further, the threshold of the head movement branch was estimated to be 85% of that required to activate gaze shifts. From these results, we conclude that a commitment to a head movement is made in advance of gaze shifts and that the comparative SSRT differences result primarily from biomechanical differences inherent to eye and head motion.

  19. Components of inhibition in autogenous- and reactive-type obsessive-compulsive disorder: Dissociation of interference control.

    PubMed

    Fan, Jie; Liu, Wanting; Lei, Hui; Cai, Lin; Zhong, Mingtian; Dong, Jiaojiao; Zhou, Cheng; Zhu, Xiongzhao

    2016-05-01

    Obsessive-compulsive disorder (OCD) is characterized by unwanted, intrusive thoughts (obsessions) and/or repetitive, ritualistic behaviors (compulsions). Findings related to the two components of inhibition, namely interference control and behavioral inhibition, among OCD patients have been inconsistent. It might be that this inconsistency is due to the heterogeneity among OCD cases representing multiple subtypes of OCD, such as autogenous obsessions and reactive obsessions types (AOs vs. ROs). AOs and ROs are distinguished by the category of their most disturbing obsessions. The purpose of this study was to systematically examine whether inhibition functions differ between AO and RO patients. We assessed interference control and behavioral inhibition with the emotional Stroop task (EST) and stop-signal task (SST), respectively, in 42 AOs, 55 ROs and 62 healthy controls (HCs) and event-related potentials (ERPs) were recorded in a random subset of these subjects (25 AOs, 25 ROs, and 31HCs). Results showed that in the EST, AOs exhibited longer reaction times (RTs) for color-naming positive-, negative-, and neutral-valence word stimulus than both ROs and HCs, and demonstrated larger P2 and less negative N450 amplitudes than HCs and larger P3 amplitudes than ROs and HCs. In the SST, both AOs and ROs showed lengthened stop signal reaction time (SSRT) and reduced Stop-P3 amplitudes in successful inhibition (SI) trials compared to the HC group. These present findings suggest that behavioral inhibition impairment may reflect a common pathology in both the autogenous- and reactive-type OCD patients, whereas interference inhibition impairment appears to be specific to patients with autogenous obsessions. These findings strengthened the insight into the clinical heterogeneity and pathophysiology of OCD. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Investigating the Conditions of the Formation of a Type II Radio Burst on 2014 January 8

    NASA Astrophysics Data System (ADS)

    Su, W.; Cheng, X.; Ding, M. D.; Chen, P. F.; Ning, Z. J.; Ji, H. S.

    2016-10-01

    It is believed that type II radio bursts are generated by shock waves. In order to understand the generation conditions of type II radio bursts, we analyze the physical parameters of a shock front. The type II radio burst we selected was observed by the Siberian Solar Radio Telescope (SSRT) and Learmonth radio station and was associated with a limb coronal mass ejection (CME) occurring on 2014 January 8 observed by the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory. The evolution of the CME in the inner corona presents a double-layered structure that propagates outward. We fit the outer layer (OL) of the structure with a partial circle and divide it into seven directions from -45° to 45° with an angular separation of 15°. We measure the OL speed along the seven directions and find that the speed in the direction of -15° with respect to the central direction is the fastest. We use the differential emission measure method to calculate the physical parameters at the OL at the moment when the type II radio burst was initiated, including the temperature (T), emission measure (EM), temperature ratio ({T}d/{T}{{u}}), compression ratio (X), and Alfvén Mach number (M A). We compare the quantities X and M A to those obtained from band-splitting in the radio spectrum, and find that this type II radio burst is generated at a small region of the OL that is located at the sector in the 45° direction. The results suggest that the generation of type II radio bursts (shocks) requires larger values of X and M A rather than simply a higher speed of the disturbance.

  1. 26 CFR 1.1274-4 - Test rate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 11 2011-04-01 2011-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...

  2. 26 CFR 1.1274-4 - Test rate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 11 2014-04-01 2014-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...

  3. 26 CFR 1.1274-4 - Test rate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 11 2013-04-01 2013-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...

  4. 26 CFR 1.1274-4 - Test rate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 11 2012-04-01 2012-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...

  5. Test Report of Special Form Qualification Testing for the ORNL U ZipCan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, Oscar A.

    This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSImore » N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.« less

  6. Well hydraulics in pumping tests with exponentially decayed rates of abstraction in confined aquifers

    NASA Astrophysics Data System (ADS)

    Wen, Zhang; Zhan, Hongbin; Wang, Quanrong; Liang, Xing; Ma, Teng; Chen, Chen

    2017-05-01

    Actual field pumping tests often involve variable pumping rates which cannot be handled by the classical constant-rate or constant-head test models, and often require a convolution process to interpret the test data. In this study, we proposed a semi-analytical model considering an exponentially decreasing pumping rate started at a certain (higher) rate and eventually stabilized at a certain (lower) rate for cases with or without wellbore storage. A striking new feature of the pumping test with an exponentially decayed rate is that the drawdowns will decrease over a certain period of time during intermediate pumping stage, which has never been seen before in constant-rate or constant-head pumping tests. It was found that the drawdown-time curve associated with an exponentially decayed pumping rate function was bounded by two asymptotic curves of the constant-rate tests with rates equaling to the starting and stabilizing rates, respectively. The wellbore storage must be considered for a pumping test without an observation well (single-well test). Based on such characteristics of the time-drawdown curve, we developed a new method to estimate the aquifer parameters by using the genetic algorithm.

  7. 77 FR 75896 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ...-11213, Notice No. 16] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013... from FRA's Management Information System, the rail industry's random drug testing positive rate has... therefore determined that the minimum annual random drug testing rate for the period January 1, 2013...

  8. Acute and chronic effects of cannabidiol on Δ⁹-tetrahydrocannabinol (Δ⁹-THC)-induced disruption in stop signal task performance.

    PubMed

    Jacobs, David S; Kohut, Stephen J; Jiang, Shan; Nikas, Spyros P; Makriyannis, Alexandros; Bergman, Jack

    2016-10-01

    Recent clinical and preclinical research has suggested that cannabidiol (CBD) and Δ9-tetrahydrocannabinol (Δ9-THC) have interactive effects on measures of cognition; however, the nature of these interactions is not yet fully characterized. To address this, we investigated the effects of Δ9-THC and CBD independently and in combination with proposed therapeutic dose ratios of 1:1 and 1:3 Δ9-THC:CBD in adult rhesus monkeys (n = 6) performing a stop signal task (SST). Additionally, the development of tolerance to the effects of Δ9-THC on SST performance was evaluated by determining the effects of acutely administered Δ9-THC (0.1-3.2 mg/kg), during a 24-day chronic Δ9-THC treatment period with Δ9-THC alone or in combination with CBD. Results indicate that Δ9-THC (0.032-0.32 mg/kg) dose-dependently decreased go success but did not alter go reaction time (RT) or stop signal RT (SSRT); CBD (0.1-1.0 mg/kg) was without effect on all measures and, when coadministered in a 1:1 dose ratio, did not exacerbate or attenuate the effects of Δ9-THC. When coadministered in a 1:3 dose ratio, CBD (1.0 mg/kg) attenuated the disruptive effects of 0.32 mg/kg Δ9-THC but did not alter the effects of other Δ9-THC doses. Increases in ED50 values for the effects of Δ9-THC on SST performance were apparent during chronic Δ9-THC treatment, with little evidence for modification of changes in sensitivity by CBD. These results indicate that CBD, when combined with Δ9-THC in clinically available dose ratios, does not exacerbate and, under restricted conditions may even attenuate, Δ9-THC's behavioral effects. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Acute and chronic effects of cannabidiol on Δ9-tetrahydrocannabinol (Δ9-THC)-induced disruption in stop signal task performance

    PubMed Central

    Jacobs, David S.; Kohut, Stephen J.; Jiang, Shan; Nikas, Spyros P.; Makriyannis, Alexandros; Bergman, Jack

    2016-01-01

    Recent clinical and preclinical research suggests that cannabidiol (CBD) and Δ9-tetrahydrocannabinol (Δ9-THC) have interactive effects on measures of cognition; however, the nature of these interactions is not yet fully characterized. To address this, the effects of Δ9-THC and CBD were investigated independently and in combination with proposed therapeutic dose ratios of 1:1 and 1:3 Δ9-THC:CBD in adult rhesus monkeys (n=6) performing a stop signal task (SST). Additionally, the development of tolerance to the effects of THC on SST performance was evaluated by determining the effects of acutely administered Δ9-THC (0.1-3.2 mg/kg), during a 24-day chronic Δ9-THC treatment period with Δ9-THC alone or with CBD. Results indicate that Δ9-THC (0.032 - 0.32 mg/kg) dose-dependently decreased ‘go’ success but did not alter ‘go’ reaction time or stop signal reaction time (SSRT); CBD (0.1-1.0 mg/kg) was without effect on all measures and, when co-administered in a 1:1 dose-ratio, did not exacerbate or attenuate the effects of Δ9-THC. When co-administered in a 1:3 dose-ratio, CBD (1.0 mg/kg) attenuated the disruptive effects of 0.32 mg/kg Δ9-THC but did not alter the effects of other Δ9-THC doses. Increases in ED50 values for the effects of Δ9-THC on SST performance were apparent during chronic Δ9-THC treatment, with little evidence for modification of changes in sensitivity by CBD. These results indicate that CBD, when combined with THC in clinically available dose-ratios does not exacerbate and, under restricted conditions, may even attenuate Δ9-THC’s behavioral effects. PMID:27690502

  10. Variability in testing policies and impact on reported Clostridium difficile infection rates: results from the pilot Longitudinal European Clostridium difficile Infection Diagnosis surveillance study (LuCID).

    PubMed

    Davies, K; Davis, G; Barbut, F; Eckert, C; Petrosillo, N; Wilcox, M H

    2016-12-01

    Lack of standardised Clostridium difficile testing is a potential confounder when comparing infection rates. We used an observational, systematic, prospective large-scale sampling approach to investigate variability in C. difficile sampling to understand C. difficile infection (CDI) incidence rates. In-patient and institutional data were gathered from 60 European hospitals (across three countries). Testing methodology, testing/CDI rates and case profiles were compared between countries and institution types. The mean annual CDI rate per hospital was lowest in the UK and highest in Italy (1.5 vs. 4.7 cases/10,000 patient bed days [pbds], p < 0.001). The testing rate was highest in the UK compared with Italy and France (50.7/10,000 pbds vs. 31.5 and 30.3, respectively, p < 0.001). Only 58.4 % of diarrhoeal samples were tested for CDI across all countries. Overall, only 64 % of hospitals used recommended testing algorithms for laboratory testing. Small hospitals were significantly more likely to use standalone toxin tests (SATTs). There was an inverse correlation between hospital size and CDI testing rate. Hospitals using SATT or assays not detecting toxin reported significantly higher CDI rates than those using recommended methods, despite testing similar testing frequencies. These data are consistent with higher false-positive rates in such (non-recommended) testing scenarios. Cases in Italy and those diagnosed by SATT or methods NOT detecting toxin were significantly older. Testing occurred significantly earlier in the UK. Assessment of testing practice is paramount to the accurate interpretation and comparison of CDI rates.

  11. Temperature and Atomic Oxygen Effects on Helium Leak Rates of a Candidate Main Interface Seal

    NASA Technical Reports Server (NTRS)

    Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.

    2011-01-01

    Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two vehicles, while docked, to prevent the escape of breathable air from the vehicles and into the vacuum of space. Leak tests completed at nominal temperatures of -30, 20, and 50 C on untreated and atomic oxygen (AO) exposed test samples were examined to determine the influence of both test temperature and AO exposure on the performance of the composite seal assembly. Results obtained for untreated seal samples showed leak rates which increased with increased test temperature. This general trend was not observed in tests of the AO exposed specimens. Initial examination of collected test data suggested that AO exposure resulted in higher helium leak rates, however, further analysis showed that the differences observed in the 20 and 50 C tests between the untreated and AO exposed samples were within the experimental error of the test method. Lack of discernable trends in the test data prevented concrete conclusions about the effects of test temperature and AO exposure on helium leak rates of the candidate seal design from being drawn. To facilitate a comparison of the current test data with results from previous leak tests using air as the test fluid, helium leak rates were converted to air leak rates using standard conversion factors for viscous and molecular flow. Flow rates calculated using the viscous flow conversion factor were significantly higher than the experimental air leakage values, whereas values calculated using the molecular flow conversion factor were significantly lower than the experimentally obtained air leak rates. The difference in these sets of converted flow rates and their deviation from the experimentally obtained air leak rate data suggest that neither conversion factor can be used alone to accurately convert helium leak rates to equivalent air leak rates for the test seals evaluated in this study; other leak phenomena, including permeation, must also be considered.

  12. Fitness for duty in the nuclear power industry. Annual summary of program performance reports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silbernagel, M.; Brichoux, J.; Durbin, N.

    This report summarizes the data from the semiannual reports on fitness-for-duty programs submitted to the NRC by utilities for two reporting periods: January 1-June 30, 1995, and July 1 -December 31, 1995. During 1995, licensees reported that they had conducted 150,121 tests for the presence of illegal drugs and alcohol. Of these tests, 1,476 (.98%) were confirmed positive. The majority of positive test results (1, 122) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 180 positive tests from random testing and 139 positive tests from for-cause testing. Follow-up testing ofmore » workers who had previously tested positive resulted in 35 positive tests. For-cause testing resulted in the highest percentage of positive tests; about 18 percent of for-cause tests were positive. This compares with a positive test rate of 1.41 percent of pre-access tests and .27 percent of random tests. The positive test rate for workers with unescorted access was .50 percent. Positive test rates also varied by category of worker. When all types of tests are combined, short-term contractor personnel had the highest positive test rate at 1.44 percent. Licensee employees and long-term contractors had lower combined positive test rates (.34% and .40%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (53.08%), followed by cocaine (24.24%) and alcohol (17.17%). The overall positive test rate for 1995 (.98%) was higher than in 1994 (.84%). Several factors had an impact on the positive test rate across test categories for 1994 and 1995 compared to previous years. These factors include the NRC`s reduction in the mandatory random testing rate from 100 percent to 50 percent, effective in 1994, and initiatives by licensees such as lowered marijuana screening cutoff levels and reported improvements in licensees ability to detect subversion of the process.« less

  13. Long-term trends in Chlamydia trachomatis infections and related outcomes in a U.S. managed care population.

    PubMed

    Scholes, Delia; Satterwhite, Catherine L; Yu, Onchee; Fine, David; Weinstock, Hillard; Berman, Stuart

    2012-02-01

    Given recent increasing case rates of Chlamydia trachomatis infection, we evaluated trends in chlamydia rates and related health outcomes in women and men aged 15 to 44 years who were enrolled in a Pacific Northwest health plan. We identified chlamydia, pelvic inflammatory disease (PID), ectopic pregnancy, and male urethritis cases occurring annually during 1997-2007 using computerized health plan databases, calculating rates per 100,000 person-years (py) by gender and 5-year age groups. We also calculated annual chlamydia testing rates. In women, chlamydia testing rates increased by approximately 23% (220 tests per 1000 py in 1997 to 270 tests per 1000 in 2007). Chlamydia diagnosis rates rose from 449 cases/100,000 py in 1997 to 806/100,000 in 2007, a 79% increase (P = 0.01). Increases were greatest during 2005-2007, also the period of major conversion to nucleic acid amplification test. PID rates in this interval declined steadily from 823 cases/100,000 py to 473/100,000 (P < 0.01). Ectopic pregnancy rates remained unchanged. In men, chlamydia testing rates increased nearly 3.5-fold, from 12 to 42 tests per 1000 py. Chlamydia rates for men also rose significantly throughout the study interval (from 91 cases/100,000 py to 218/100,000; P < 0.01) as did urethritis diagnosis rates (P < 0.01). Between 1997 and 2007, annual health plan chlamydia rates increased significantly for both women and men. These trends may be due in part to increased testing rates and increased use of more sensitive tests, but they likely do not explain the increased urethritis rates. During this same interval, we observed steady declines in PID rates, consistent with other national data sources.

  14. 78 FR 4855 - Random Drug Testing Rate for Covered Crewmembers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-23

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2013 minimum random drug testing rate at 25 percent of...

  15. 76 FR 79204 - Random Drug Testing Rate for Covered Crewmembers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-21

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2012 minimum random drug testing rate at 50 percent of...

  16. 76 FR 1448 - Random Drug Testing Rate for Covered Crewmembers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-10

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2011 minimum random drug testing rate at 50 percent of...

  17. A study of the 200-metre fast walk test as a possible new assessment tool to predict maximal heart rate and define target heart rate for exercise training of coronary heart disease patients.

    PubMed

    Casillas, Jean-Marie; Joussain, Charles; Gremeaux, Vincent; Hannequin, Armelle; Rapin, Amandine; Laurent, Yves; Benaïm, Charles

    2015-02-01

    To develop a new predictive model of maximal heart rate based on two walking tests at different speeds (comfortable and brisk walking) as an alternative to a cardiopulmonary exercise test during cardiac rehabilitation. Evaluation of a clinical assessment tool. A Cardiac Rehabilitation Department in France. A total of 148 patients (133 men), mean age of 59 ±9 years, at the end of an outpatient cardiac rehabilitation programme. Patients successively performed a 6-minute walk test, a 200 m fast-walk test (200mFWT), and a cardiopulmonary exercise test, with measure of heart rate at the end of each test. An all-possible regression procedure was used to determine the best predictive regression models of maximal heart rate. The best model was compared with the Fox equation in term of predictive error of maximal heart rate using the paired t-test. Results of the two walking tests correlated significantly with maximal heart rate determined during the cardiopulmonary exercise test, whereas anthropometric parameters and resting heart rate did not. The simplified predictive model with the most acceptable mean error was: maximal heart rate = 130 - 0.6 × age + 0.3 × HR200mFWT (R(2) = 0.24). This model was superior to the Fox formula (R(2) = 0.138). The relationship between training target heart rate calculated from measured reserve heart rate and that established using this predictive model was statistically significant (r = 0.528, p < 10(-6)). A formula combining heart rate measured during a safe simple fast walk test and age is more efficient than an equation only including age to predict maximal heart rate and training target heart rate. © The Author(s) 2014.

  18. A Search for Factors Causing Training Costs to Rise by Examining the U. S. Navy’s AT, AW, and AX Ratings during their First Enlistment Period

    DTIC Science & Technology

    1986-09-01

    HYPOTHESIS TEST .................... 20 III. TIME TO GET RATED TWO FACTOR ANOVA RESULTS ......... 23 IV. TIME TO GET RATED TUKEY’S PAIRED COvfl’PARISON... TEST RESULTS A ............................................ 24 V. TIME TO GET RATED TUKEY’S PAIRED COMPARISON TEST RESULTS B...25 VI. SINGLE FACTOR ANOVA HYPOTHESIS TEST #I............... 27 VII. AT: TIME TO GET RATED ANOVA TEST RESULTS ............. 30

  19. The Application of Stress-Relaxation Test to Life Assessment of T911/T22 Weld Metal

    NASA Astrophysics Data System (ADS)

    Cao, Tieshan; Zhao, Jie; Cheng, Congqian; Li, Huifang

    2016-03-01

    A dissimilar weld metal was obtained through submerged arc welding of a T911 steel to a T22 steel, and its creep property was explored by stress-relaxation test assisted by some conventional creep tests. The creep rate information of the stress-relaxation test was compared to the minimum and the average creep rates of the conventional creep test. Log-log graph showed that the creep rate of the stress-relaxation test was in a linear relationship with the minimum creep rate of the conventional creep test. Thus, the creep rate of stress-relaxation test could be used in the Monkman-Grant relation to calculate the rupture life. The creep rate of the stress-relaxation test was similar to the average creep rate, and thereby the rupture life could be evaluated by a method of "time to rupture strain." The results also showed that rupture life which was assessed by the Monkman-Grant relation was more accurate than that obtained through the method of "time to rupture strain."

  20. T-SPOT.TB Interferon-γ Release Assay Performance in Healthcare Worker Screening at Nineteen U.S. Hospitals.

    PubMed

    King, Thomas C; Upfal, Mark; Gottlieb, Andrew; Adamo, Philip; Bernacki, Edward; Kadlecek, Chris P; Jones, Jeffrey G; Humphrey-Carothers, Frances; Rielly, Albert F; Drewry, Pamela; Murray, Kathy; DeWitt, Marcie; Matsubara, Janet; O'Dea, Louis; Balser, John; Wrighton-Smith, Peter

    2015-08-01

    Interferon-γ release assays have significant advantages over tuberculin skin testing in many clinical situations. However, recent studies have called into question their reliability in serial testing of healthcare workers because of reportedly high rates of positivity and high conversion/reversion rates on retesting. To define the performance characteristics of the T-SPOT.TB test, an interferon-γ release assay, during serial screening programs of healthcare workers at 19 U.S. hospitals. A total of 42,155 T-SPOT.TB test results from healthcare workers at 19 geographically diverse hospitals obtained for routine tuberculosis screening programs were analyzed to determine the rates of positivity, reversion, and conversion in serial testing data. In 19,630 evaluable serial pairs from 16,076 healthcare workers, the mean test positivity rate was 2.3% (range, 0.0-27.4%). The mean conversion rate was 0.8% (range, 0.0-2.5%), and the mean reversion rate was 17.6%. Positivity and conversion rates correlated with known tuberculosis risk factors including age and sex. The observed specificity of the T-SPOT.TB test was at least 98.6%. The high concordance and test completion rates in this study suggest that the T-SPOT.TB test is a reliable tool for healthcare worker serial screening. As expected, the observed positivity rates were lower compared with the tuberculin skin test, likely reflecting the higher specificity of this test. Furthermore, the observed rates of conversion were low and significantly correlated with the geographic incidence of tuberculosis. Our findings suggest that the T-SPOT.TB test is an accurate and reliable way to screen healthcare workers.

  1. 75 FR 76078 - Pipeline Safety: Random Drug Testing Rate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-07

    ... PHMSA-2010-0323] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... testing. SUMMARY: PHMSA has determined that the minimum random drug testing rate for covered employees... employees for random drug testing. Pursuant to 49 CFR 199.105(c)(2), (3), and (4), the PHMSA Administrator's...

  2. Stress Testing After Percutaneous Coronary Intervention in the Veterans Affairs HealthCare System: Insights from the Veterans Affairs Clinical Assessment, Reporting, and Tracking Program.

    PubMed

    Bradley, Steven M; Hess, Edward; Winchester, David E; Sussman, Jeremy B; Aggarwal, Vikas; Maddox, Thomas M; Barón, Anna E; Rumsfeld, John S; Ho, P Michael

    2015-09-01

    Stress testing after percutaneous coronary intervention (PCI) in fee-for-service settings is common and rates vary by hospital. Rates of stress testing after PCI within integrated healthcare systems, such as the Veterans Affairs (VA) are unknown. We evaluated all VA patients who underwent PCI from October 2007 through June 2010. To avoid the influence of Medicare eligibility on rates of stress testing use in the VA, we excluded Medicare eligible patients during the follow-up period. Hospital-level variation in risk-standardized rates of stress testing and the association with 1-year mortality and myocardial infarction was determined from Markov chain Monte Carlo methods. Among 10 293 patients undergoing PCI at 55 VA hospitals, 2239 (21.8%) had a stress test performed within 1 year of PCI and 3902 (37.9%) within 2 years. Most stress tests after PCI were performed with nuclear imaging (79.8%). The hospital-level risk-standardized rate of stress testing differed significantly from the average at 14 hospitals, with 8 (14.5%) hospitals significantly below and 6 (10.9%) hospitals significantly above the average stress testing rate. Hospital-level risk-standardized stress testing rates were not significantly correlated with risk-standardized mortality (Spearman ρ=-0.24; P=0.08) or myocardial infarction rates (Spearman ρ=0.20; P=0.14). In the VA, nearly 40% of patients underwent stress testing in the 2 years after PCI, which is a third less than published studies from other healthcare systems. However, stress testing rates varied across VA hospitals, suggesting opportunities to optimize the use of stress testing are still present in integrated healthcare systems. © 2015 American Heart Association, Inc.

  3. 26 CFR 1.483-3 - Test rate of interest applicable to a contract.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 6 2010-04-01 2010-04-01 false Test rate of interest applicable to a contract... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Adjustments § 1.483-3 Test rate of interest applicable to a contract. (a) General rule. For purposes of section 483, the test rate of interest for a contract is the...

  4. Ultra High Strain Rate Nanoindentation Testing.

    PubMed

    Sudharshan Phani, Pardhasaradhi; Oliver, Warren Carl

    2017-06-17

    Strain rate dependence of indentation hardness has been widely used to study time-dependent plasticity. However, the currently available techniques limit the range of strain rates that can be achieved during indentation testing. Recent advances in electronics have enabled nanomechanical measurements with very low noise levels (sub nanometer) at fast time constants (20 µs) and high data acquisition rates (100 KHz). These capabilities open the doors for a wide range of ultra-fast nanomechanical testing, for instance, indentation testing at very high strain rates. With an accurate dynamic model and an instrument with fast time constants, step load tests can be performed which enable access to indentation strain rates approaching ballistic levels (i.e., 4000 1/s). A novel indentation based testing technique involving a combination of step load and constant load and hold tests that enables measurement of strain rate dependence of hardness spanning over seven orders of magnitude in strain rate is presented. A simple analysis is used to calculate the equivalent uniaxial response from indentation data and compared to the conventional uniaxial data for commercial purity aluminum. Excellent agreement is found between the indentation and uniaxial data over several orders of magnitude of strain rate.

  5. Variation of strain rate sensitivity index of a superplastic aluminum alloy in different testing methods

    NASA Astrophysics Data System (ADS)

    Majidi, Omid; Jahazi, Mohammad; Bombardier, Nicolas; Samuel, Ehab

    2017-10-01

    The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.

  6. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    PubMed

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  7. 75 FR 17169 - Nextera Energy Duane Arnold, LLC, Duane Arnold Energy Center; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... leakage from the overall integrated leak rate test measurement. Main steam leakage includes leakage... integrated leakage rate (Type A) test measurement and from the sum of the leakage rates from local leakage... leakage rate (Type A) test [[Page 17170

  8. Diagnostic triage and the role of natriuretic peptide testing and echocardiography for suspected heart failure: an appropriateness ratings evaluation by UK GPs

    PubMed Central

    Campbell, Stephen M; Fuat, Ahmet; Summerton, Nick; Lancaster, Neil; Hobbs, FD Richard

    2011-01-01

    Background Some UK GPs are acquiring access to natriuretic peptide (NP) testing or echocardiography as diagnostic tests for heart failure. This study developed appropriateness ratings for the diagnostic application of these tests in routine general practice. Aim To develop appropriateness ratings for the diagnostic application of NP testing or echocardiography for heart failure in general practice. Design and setting An appropriateness ratings evaluation in UK general practice. Method Four presenting symptoms (cough, bilateral ankle swelling, dyspnoea, fatigue), three levels of risk of cardiovascular disease (low, intermediate, high), and dichotomous categorisations of cardiovascular/chest examination and electrocardiogram result, were used to create 540 appropriateness scenarios for patients in whom NP testing or echocardiography might be considered. These were rated by a 10-person expert panel, consisting of GPs and GPs with specialist interests in cardiology, in a two-round RAND Appropriateness Method. Results Onward referral for NP testing or echocardiography was rated as an appropriate next step in 217 (40.2%) of the 540 scenarios; in 194 (35.9%) it was rated inappropriate. The ratings also show where NP testing or echocardiography were ranked as equivalent next steps and when one test was seen as the more appropriate than the other. Conclusion NP testing should be the routine test for suspected heart failure where referral for diagnostic testing is considered appropriate. An abnormal electrocardiogram status makes referral to echocardiography an accompanying, or more appropriate, next step alongside NP testing, especially in the presence of dyspnoea. Abnormal NP testing should subsequently be followed up with referral for echocardiography. PMID:21722451

  9. [Study on the stability of tetrandrine microsphere].

    PubMed

    Cheng, Guohu; Luo, Jiabo

    2005-05-01

    To study the stability of Tetrandrine Microsphere. Higher speed test and room temperature test were adopted to investigate the indexes, such as properties of appearance, amount of medicine loaded, seal rate, seepage rate, microbial stability, etc. Through the test of six months, properties of appearance, amount of medicine loaded, seal rate, seepage rate, microbial stability have not obviously change. But after testing for 6 months with higher temperature, the seal rate was reduced, and the seepage rate was increased. Tetrandrine microsphere is steady under the room temperature condition, but is unstable to hot, and ought to keep in conformity with low-temperature.

  10. ASTM F739 method for testing the permeation resistance of protective clothing materials: critical analysis with proposed changes in procedure and test-cell design.

    PubMed

    Anna, D H; Zellers, E T; Sulewski, R

    1998-08-01

    ASTM (American Society for Testing and Materials) Method F739-96 specifies a test-cell design and procedures for measuring the permeation resistance of chemical protective clothing. Among the specifications are open-loop collection stream flow rates of 0.050 to 0.150 L/min for a gaseous medium. At elevated temperatures the test must be maintained within 1 degree C of the set point. This article presents a critical analysis of the effect of the collection stream flow rate on the measured permeation rate and on the temperature uniformity within the test cell. Permeation tests were conducted on four polymeric glove materials with 44 solvents at 25 degrees C. Flow rates > 0.5 L/min were necessary to obtain accurate steady-state permeation rate (SSPR) values in 25 percent of the tests. At the lower flow rates the true SSPR typically was underestimated by a factor of two or less, but errors of up to 33-fold were observed. No clear relationship could be established between the need for a higher collection stream flow rate and either the vapor pressure or the permeation rate of the solvent, but test results suggest that poor mixing within the collection chamber was a contributing factor. Temperature gradients between the challenge and collection chambers and between the bottom and the top of the collection chamber increased with the water-bath temperature and the collection stream flow rate. Use of a test cell modified to permit deeper submersion reduced the gradients to < or = 0.5 degrees C. It is recommended that all SSPR measurements include verification of the adequacy of the collection stream flow rate. For testing at nonambient temperatures, the modified test cell described here could be used to ensure temperature uniformity throughout the cell.

  11. Instrument Rating Practical Test Standards for Airplane, Helicopter, Airship

    DOT National Transportation Integrated Search

    1994-10-01

    The Instrument Rating Practical Test Standards (PTS) book has : been published by the Federal Aviation Administration (FAA) to : establish the standards for the instrument rating practical test for : airplanes, helicopters, and airships. FAA inspecto...

  12. The Dutch Review Process for Evaluating the Quality of Psychological Tests: History, Procedure, and Results

    ERIC Educational Resources Information Center

    Evers, Arne; Sijtsma, Klaas; Lucassen, Wouter; Meijer, Rob R.

    2010-01-01

    This article describes the 2009 revision of the Dutch Rating System for Test Quality and presents the results of test ratings from almost 30 years. The rating system evaluates the quality of a test on seven criteria: theoretical basis, quality of the testing materials, comprehensiveness of the manual, norms, reliability, construct validity, and…

  13. Improving Accuracy of Influenza-Associated Hospitalization Rate Estimates

    PubMed Central

    Reed, Carrie; Kirley, Pam Daily; Aragon, Deborah; Meek, James; Farley, Monica M.; Ryan, Patricia; Collins, Jim; Lynfield, Ruth; Baumbach, Joan; Zansky, Shelley; Bennett, Nancy M.; Fowler, Brian; Thomas, Ann; Lindegren, Mary L.; Atkinson, Annette; Finelli, Lyn; Chaves, Sandra S.

    2015-01-01

    Diagnostic test sensitivity affects rate estimates for laboratory-confirmed influenza–associated hospitalizations. We used data from FluSurv-NET, a national population-based surveillance system for laboratory-confirmed influenza hospitalizations, to capture diagnostic test type by patient age and influenza season. We calculated observed rates by age group and adjusted rates by test sensitivity. Test sensitivity was lowest in adults >65 years of age. For all ages, reverse transcription PCR was the most sensitive test, and use increased from <10% during 2003–2008 to ≈70% during 2009–2013. Observed hospitalization rates per 100,000 persons varied by season: 7.3–50.5 for children <18 years of age, 3.0–30.3 for adults 18–64 years, and 13.6–181.8 for adults >65 years. After 2009, hospitalization rates adjusted by test sensitivity were ≈15% higher for children <18 years, ≈20% higher for adults 18–64 years, and ≈55% for adults >65 years of age. Test sensitivity adjustments improve the accuracy of hospitalization rate estimates. PMID:26292017

  14. Enhanced Low Dose Rate Effects in Bipolar Circuits: A New Hardness Assurance Problem for NASA

    NASA Technical Reports Server (NTRS)

    Johnston, A.; Barnes, C.

    1995-01-01

    Many bipolar integrated circuits are much more susceptible to ionizing radiation at low dose rates than they are at high dose rates typically used for radiation parts testing. Since the low dose rate is equivalent to that seen in space, the standard lab test no longer can be considered conservative and has caused the Air Force to issue an alert. Although a reliable radiation hardness assurance test has not yet been designed, possible mechanisms for low dose rate enhancement and hardness assurance tests are discussed.

  15. Fighter pilots' heart rate, heart rate variation and performance during an instrument flight rules proficiency test.

    PubMed

    Mansikka, Heikki; Virtanen, Kai; Harris, Don; Simola, Petteri

    2016-09-01

    Increased task demand will increase the pilot mental workload (PMWL). When PMWL is increased, mental overload may occur resulting in degraded performance. During pilots' instrument flight rules (IFR) proficiency test, PMWL is typically not measured. Therefore, little is known about workload during the proficiency test and pilots' potential to cope with higher task demands than those experienced during the test. In this study, fighter pilots' performance and PMWL was measured during a real IFR proficiency test in an F/A-18 simulator. PMWL was measured using heart rate (HR) and heart rate variation (HRV). Performance was rated using Finnish Air Force's official rating scales. Results indicated that HR and HRV differentiate varying task demands in situations where variations in performance are insignificant. It was concluded that during a proficiency test, PMWL should be measured together with the task performance measurement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Autonomic changes after treatment of agoraphobia with panic attacks.

    PubMed

    Roth, W T; Telch, M J; Taylor, C B; Agras, W S

    1988-04-01

    Twenty-three patients meeting DSM-III criteria for agoraphobia with panic attacks and 14 age-, race-, and sex-matched nonanxious controls were tested in the laboratory and on a test walk in a shopping mall. The patients were tested before and after about 15 weeks of treatment with placebo and exposure therapy, imipramine and exposure therapy, or imipramine and initial antiexposure instructions. Controls were tested twice at a similar interval, but without any treatment. On test day 1, patients compared to controls showed higher average heart rate and skin conductance levels and greater numbers of skin conductance fluctuations in the laboratory, and higher heart rates before and during the test walk. Between pretreatment and posttreatment tests, clinical ratings improved and skin conductance levels decreased in all treatment groups. Heart rate levels in the laboratory, on the other hand, decreased in patients on placebo and rose in patients on imipramine. Thus, imipramine compromises the usefulness of heart rate as a measure of emotional arousal. Higher pretreatment heart rates predicted greater clinical improvement.

  17. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    PubMed

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  18. Validation of Test Methods for Air Leak Rate Verification of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Oravec, Heather Ann; Daniels, Christopher C.; Mather, Janice L.

    2017-01-01

    As deep space exploration continues to be the goal of NASAs human spaceflight program, verification of the performance of spaceflight hardware becomes increasingly critical. Suitable test methods for verifying the leak rate of sealing systems are identified in program qualification testing requirements. One acceptable method for verifying the air leak rate of gas pressure seals is the tracer gas leak detector method. In this method, a tracer gas (commonly helium) leaks past the test seal and is transported to the leak detector where the leak rate is quantified. To predict the air leak rate, a conversion factor of helium-to-air is applied depending on the magnitude of the helium flow rate. The conversion factor is based on either the molecular mass ratio or the ratio of the dynamic viscosities. The current work was aimed at validating this approach for permeation-level leak rates using a series of tests with a silicone elastomer O-ring. An established pressure decay method with constant differential pressure was used to evaluate both the air and helium leak rates of the O-ring under similar temperature and pressure conditions. The results from the pressure decay tests showed, for the elastomer O-ring, that neither the molecular flow nor the viscous flow helium-to-air conversion factors were applicable. Leak rate tests were also performed using nitrogen and argon as the test gas. Molecular mass and viscosity based helium-to-test gas conversion factors were applied, but did not correctly predict the measured leak rates of either gas. To further this study, the effect of pressure boundary conditions was investigated. Often, pressure decay leak rate tests are performed at a differential pressure of 101.3 kPa with atmospheric pressure on the downstream side of the test seal. In space applications, the differential pressure is similar, but with vacuum as the downstream pressure. The same O-ring was tested at four unique differential pressures ranging from 34.5 to 137.9 kPa. Up to six combinations of upstream and downstream pressures for each differential pressure were compared. For a given differential pressure, the various combinations of upstream and downstream dry air pressures did not significantly affect the leak rate. As expected, the leak rate of the O-ring increased with increasing differential pressure. The results suggested that the current leak test pressure conditions, used to verify spacecraft sealing systems with elastomer seals, produce accurate values even though the boundary conditions do not model the space application.

  19. 49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...

  20. 49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...

  1. 49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...

  2. 49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...

  3. 49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...

  4. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  5. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  6. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  7. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...

  8. Benign paroxysmal vertigo of childhood: diagnostic value of vestibular test and high stimulus rate auditory brainstem response test.

    PubMed

    Zhang, Daogong; Fan, Zhaomin; Han, Yuechen; Wang, Mingming; Xu, Lei; Luo, Jianfen; Ai, Yu; Wang, Haibo

    2012-01-01

    To investigate the diagnostic value of vestibular test and high stimulus rate auditory brainstem response (ABR) test and the possible mechanism responsible for benign paroxysmal vertigo of childhood (BPVC). Data of 56 patients with BPVC in vertigo clinic of our hospital from May 2007 to September 2008 were retrospectively analyzed in this study. Patients with BPVC were tested with pure tone audiometry, high stimulus rate auditory brainstem response test (ABR), transcranial Doppler sonography (TCD), bithermal caloric test, and VEMP. The results of the hearing and vestibular function test were compared and analyzed. There were 56 patients with BPVC, including 32 men, 24 women, aged 3-12 years old, with an average of 6.5 years. Among 56 cases of BPVC patients, the results of pure tone audiometry were all normal. High stimulus rate ABR was abnormal in 66.1% (37/56) of cases. TCD showed 57.1% abnormality in 56 cases, including faster flow rate in 28 cases and slower flow rate in 4 cases. High stimulus rate ABR and TCD were both abnormal in 48.2% (27/56) of cases. Bithermal caloric test was abnormal in 14.3% (8/56) of cases. VEMP showed 32.1% abnormality, including amplitude abnormality in 16 cases and latency abnormality in 2 cases. The abnormal rate of VEMP was much higher than that of caloric test. Vascular mechanisms might be involved in the pathogenesis of BPVC and there is strong evidence for close relationship between BPVC and migraine. High stimulus rate ABR is helpful in the diagnosis of BPVC. The inferior vestibular pathway is much more impaired than the superior vestibular pathway in BPVC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Fitness for duty in the nuclear power industry. Volume 2, Annual summary of program performance reports, CY 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, S.; Fleming, T.; Westra, C.

    This report summarizes the data from the semi-annual reports on fitness-for-duty programs submitted to the NRC by 52 utilities for two reporting periods: January 1, 1991 to June 30,1991, and from July 1, 1991, to December 31, 1991. During 1991, licensees reported that they had conducted 262,597 tests for the presence of illegal drugs and alcohol. Of these tests, 1,722 (.66%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (983) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, theremore » were 510 positive tests from random testing and 167 positive tests from forcause testing. Follow-up testing of workers who had previously tested positive resulted in 62 positive tests. Forcause testing resulted in the highest percentage of positive tests; about 23 percent of forcause tests were positive. This compares to a positive test rate of .94 percent of preaccess tests and .33 percent of random tests. Positive test rates also varied by category of worker. Overall, short-term contractor personnel had the highest positive test rate at .98 percent. licensee employees and long-term contractors had lower positive test rates (33% and .56%, respectively). Of the substances tested, marijuana was responsible for the highest percentage (42.3%) of positive test results, followed by cocaine (31.2%) and alcohol (22.8%). Positive test results are also reported for NRC administrative regions, for plants experiencing or not experiencing an outage during a six-month period; and for plants located in areas with different rates of population density, crime, and drug and alcohol use. A comparison of positive test results in 1991 with those found in 1990 found a decrease in the positive test rate for each category of test and worker.« less

  10. Fitness for duty in the nuclear power industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, S.; Fleming, T.; Westra, C.

    This report summarizes the data from the semi-annual reports on fitness-for-duty programs submitted to the NRC by 52 utilities for two reporting periods: January 1, 1991 to June 30,1991, and from July 1, 1991, to December 31, 1991. During 1991, licensees reported that they had conducted 262,597 tests for the presence of illegal drugs and alcohol. Of these tests, 1,722 (.66%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (983) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, theremore » were 510 positive tests from random testing and 167 positive tests from forcause testing. Follow-up testing of workers who had previously tested positive resulted in 62 positive tests. Forcause testing resulted in the highest percentage of positive tests; about 23 percent of forcause tests were positive. This compares to a positive test rate of .94 percent of preaccess tests and .33 percent of random tests. Positive test rates also varied by category of worker. Overall, short-term contractor personnel had the highest positive test rate at .98 percent. licensee employees and long-term contractors had lower positive test rates (33% and .56%, respectively). Of the substances tested, marijuana was responsible for the highest percentage (42.3%) of positive test results, followed by cocaine (31.2%) and alcohol (22.8%). Positive test results are also reported for NRC administrative regions, for plants experiencing or not experiencing an outage during a six-month period; and for plants located in areas with different rates of population density, crime, and drug and alcohol use. A comparison of positive test results in 1991 with those found in 1990 found a decrease in the positive test rate for each category of test and worker.« less

  11. Cognitive tests predict real-world errors: the relationship between drug name confusion rates in laboratory-based memory and perception tests and corresponding error rates in large pharmacy chains

    PubMed Central

    Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L

    2017-01-01

    Background Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. Objectives We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Methods Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Results Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Conclusions Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. PMID:27193033

  12. Empirical Tests of the Assumptions Underlying Models for Foreign Exchange Rates.

    DTIC Science & Technology

    1984-03-01

    Research Report COs 481 EMPIRICAL TESTS OF THE ASSUMPTIO:IS UNDERLYING MODELS FOR FOREIGN EXCHANGE RATES by P. Brockett B. Golany 00 00 CENTER FOR...Research Report CCS 481 EMPIRICAL TESTS OF THE ASSUMPTIONS UNDERLYING MODELS FOR FOREIGN EXCHANGE RATES by P. Brockett B. Golany March 1984...applying these tests to the U.S. dollar to Japanese Yen foreign exchange rates . Conclusions and discussion is given in section VI. 1The previous authors

  13. Decreased Variability of the 6-Minute Walk Test by Heart Rate Correction in Patients with Neuromuscular Disease

    PubMed Central

    Prahm, Kira P.; Witting, Nanna; Vissing, John

    2014-01-01

    Objective The 6-minute walk test is widely used to assess functional status in neurological disorders. However, the test is subject to great inter-test variability due to fluctuating motivation, fatigue and learning effects. We investigated whether inter-test variability of the 6MWT can be reduced by heart rate correction. Methods Sixteen patients with neuromuscular diseases, including Facioscapulohumeral muscular dystrophy, Limb-girdle muscular dystrophy, Charcot-Marie-Tooths, Dystrophia Myotonica and Congenital Myopathy and 12 healthy subjects were studied. Patients were excluded if they had cardiac arrhythmias, if they received drug treatment for hypertension or any other medical conditions that could interfere with the interpretation of the heart rate and walking capability. All completed three 6-minute walk tests on three different test-days. Heart rate was measured continuously. Results Successive standard 6-minute walk tests showed considerable learning effects between Tests 1 and 2 (4.9%; P = 0.026), and Tests 2 and 3 (4.5%; P = 0.020) in patients. The same was seen in controls between Tests 1 and 2 (8.1%; P = 0.039)). Heart rate correction abolished this learning effect. Conclusion A modified 6-minute walk test, by correcting walking distance with average heart rate during walking, decreases the variability among repeated 6-minute walk tests, and should be considered as an alternative outcome measure to the standard 6-minute walk test in future clinical follow-up and treatment trials. PMID:25479403

  14. Errors of car wheels rotation rate measurement using roller follower on test benches

    NASA Astrophysics Data System (ADS)

    Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.

    2018-03-01

    The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.

  15. [Effect of Music Intervention on Maternal Anxiety and Fetal Heart Rate Pattern During Non-Stress Test].

    PubMed

    Oh, Myung Ok; Kim, Young Jeoum; Baek, Cho Hee; Kim, Ju Hee; Park, No Mi; Yu, Mi Jeong; Song, Han Sol

    2016-06-01

    The purpose of this cross-over experimental study was to examine effects of music intervention on maternal anxiety, fetal heart rate pattern and testing time during non-stress tests (NST) for antenatal fetal assessment. Sixty pregnant women within 28 to 40 gestational weeks were randomly assigned to either the experimental group (n=30) or control group (n=30). Music intervention was provided to pregnant women in the experimental group during NST. Degree of maternal anxiety and fetal heart rate pattern were our primary outcomes. State-trait anxiety inventory, blood pressure, pulse rate, and changes in peripheral skin temperature were assessed to determine the degree of maternal anxiety. Baseline fetal heart rate, frequency of acceleration in fetal heart rate, fetal movement test and testing time for reactive NST were assessed to measure the fetal heart rate pattern. The experimental group showed significantly lower scores in state anxiety than the control group. There were no significant differences in systolic blood pressure and pulse rate between the two groups. Baseline fetal heart rate was significantly lower in the experimental group than in the control group. Frequency of acceleration in fetal heart rate was significantly increased in the experimental group compared to the control group. There were no significant differences in fetal movement and testing time for reactive NST between the two groups. Present results suggest that music intervention could be an effective nursing intervention for alel viating anxiety during non-stress test.

  16. Total dose bias dependency and ELDRS effects in bipolar linear devices

    NASA Technical Reports Server (NTRS)

    Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.

    2002-01-01

    Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

  17. Measurement at low strain rates of the elastic properties of dental polymeric materials.

    PubMed

    Chabrier, F; Lloyd, C H; Scrimgeour, S N

    1999-01-01

    To evaluate a simple static test (i.e. a slow strain rate test) designed to measure Young's modulus and the bulk modulus of polymeric materials (The NOL Test). Though it is a 'mature' test as yet it has never been applied to dental materials. A small cylindrical specimen is contained in a close-fitting steel constraining ring and compressive force applied to the ends by steel pistons. The initial (unconstrained) deformation is controlled by Young's modulus. Lateral spreading leads to constraint from the ring and subsequent deformation is controlled by the bulk modulus. A range of dental materials and reference polymers were selected and both moduli measured. From these data Poisson's ratios were calculated. The test proved be a simple reliable method for obtaining values for these properties. For composite the value of Young's modulus was lower, bulk modulus relatively similar and Poisson's ratio higher than that obtained from high strain rate techniques (as expected for a strain rate sensitive material). This test does fulfil a requirement for a simple test to define fully the elastic properties of dental polymeric materials. Measurements are made at the strain rates used in conventional static tests and values reflect this test condition. The higher values obtained for Poisson's ratio at this slow strain rate has implications for FEA, in that analysis is concerned with static or slow rate loading situations.

  18. Prediction of failure pressure and leak rate of stress corrosion.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majumdar, S.; Kasza, K.; Park, J. Y.

    2002-06-24

    An ''equivalent rectangular crack'' approach was employed to predict rupture pressures and leak rates through laboratory generated stress corrosion cracks and steam generator tubes removed from the McGuire Nuclear Station. Specimen flaws were sized by post-test fractography in addition to a pre-test advanced eddy current technique. The predicted and observed test data on rupture and leak rate are compared. In general, the test failure pressures and leak rates are closer to those predicted on the basis of fractography than on nondestructive evaluation (NDE). However, the predictions based on NDE results are encouraging, particularly because they have the potential to determinemore » a more detailed geometry of ligamented cracks, from which failure pressure and leak rate can be more accurately predicted. One test specimen displayed a time-dependent increase of leak rate under constant pressure.« less

  19. Sample features associated with success rates in population-based EGFR mutation testing.

    PubMed

    Shiau, Carolyn J; Babwah, Jesse P; da Cunha Santos, Gilda; Sykes, Jenna R; Boerner, Scott L; Geddie, William R; Leighl, Natasha B; Wei, Cuihong; Kamel-Reid, Suzanne; Hwang, David M; Tsao, Ming-Sound

    2014-07-01

    Epidermal growth factor receptor (EGFR) mutation testing has become critical in the treatment of patients with advanced non-small-cell lung cancer. This study involves a large cohort and epidemiologically unselected series of EGFR mutation testing for patients with nonsquamous non-small-cell lung cancer in a North American population to determine sample-related factors that influence success in clinical EGFR testing. Data from consecutive cases of Canadian province-wide testing at a centralized diagnostic laboratory for a 24-month period were reviewed. Samples were tested for exon-19 deletion and exon-21 L858R mutations using a validated polymerase chain reaction method with 1% to 5% detection sensitivity. From 2651 samples submitted, 2404 samples were tested with 2293 samples eligible for analysis (1780 histology and 513 cytology specimens). The overall test-failure rate was 5.4% with overall mutation rate of 20.6%. No significant differences in the failure rate, mutation rate, or mutation type were found between histology and cytology samples. Although tumor cellularity was significantly associated with test-success or mutation rates in histology and cytology specimens, respectively, mutations could be detected in all specimen types. Significant rates of EGFR mutation were detected in cases with thyroid transcription factor (TTF)-1-negative immunohistochemistry (6.7%) and mucinous component (9.0%). EGFR mutation testing should be attempted in any specimen, whether histologic or cytologic. Samples should not be excluded from testing based on TTF-1 status or histologic features. Pathologists should report the amount of available tumor for testing. However, suboptimal samples with a negative EGFR mutation result should be considered for repeat testing with an alternate sample.

  20. Airline Transport Pilot and/or Type Rating - Practical Test Standards for Airplane, Helicopter

    DOT National Transportation Integrated Search

    1995-07-01

    The Airline Transport Pilot and/or Type Rating Practical Test Standards : (PTS) book has been published by the Federal Aviation Administration : (FAA) to establish the standards for Airline Transport Pilot and Type Rating : practical tests for airpla...

  1. Validation of Empirically Derived Rating Scales for a Story Retelling Speaking Test

    ERIC Educational Resources Information Center

    Hirai, Akiyo; Koizumi, Rie

    2013-01-01

    In recognition of the rating scale as a crucial tool of performance assessment, this study aims to establish a rating scale suitable for a Story Retelling Speaking Test (SRST), which is a semidirect test of speaking ability in English as a foreign language for classroom use. To identify an appropriate scale, three rating scales, all of which have…

  2. Dependency of Shear Strength on Test Rate in SiC/BSAS Ceramic Matrix Composite at Elevated Temperature

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Bansal, Narottam P.; Gyekenyesi, John P.

    2003-01-01

    Both interlaminar and in-plane shear strengths of a unidirectional Hi-Nicalon(TM) fiber-reinforced barium strontium aluminosilicate (SiC/BSAS) composite were determined at 1100 C in air as a function of test rate using double notch shear test specimens. The composite exhibited a significant effect of test rate on shear strength, regardless of orientation which was either in interlaminar or in in-plane direction, resulting in an appreciable shear-strength degradation of about 50 percent as test rate decreased from 3.3 10(exp -1) mm/s to 3.3 10(exp -5) mm/s. The rate dependency of composite's shear strength was very similar to that of ultimate tensile strength at 1100 C observed in a similar composite (2-D SiC/BSAS) in which tensile strength decreased by about 60 percent when test rate varied from the highest (5 MPa/s) to the lowest (0.005 MPa/s). A phenomenological, power-law slow crack growth formulation was proposed and formulated to account for the rate dependency of shear strength of the composite.

  3. Testing-adjusted chlamydia notification trends in New South Wales, Australia, 2000 to 2010.

    PubMed

    Cretikos, Michelle; Mayne, Darren; Reynolds, Roderick; Spokes, Paula; Madeddu, Daniel

    2014-01-01

    Between 2005 and 2010, Australian notification rates for chlamydia infection increased by 64% from 203 to 333 per 100 000 population. Interpreting this trend is difficult without examining rates and local patterns of testing. We examined the effect of adjusting for local testing rates on chlamydia notification trends in New South Wales (NSW), Australia from 2000 to 2010. We used testing data for NSW residents for Medicare Benefits Schedule items for chlamydia from 1 July 1999 to 30 June 2005 and 1 July 2007 to 30 June 2010. This data set excluded testing by public sector laboratories. We also obtained laboratory-confirmed genital chlamydia notifications in NSW residents for 1 July 1999 to 30 June 2010 and excluded notifications from public laboratories. We used negative binomial regression to assess trends in chlamydia notification rates by age and sex after adjusting for local government area (LGA)-level Medicare-funded testing rates, socioeconomic disadvantage, remoteness and Medicare provider density. Testing-adjusted rates of chlamydia notifications declined by 5.2% per annum (rate ratio [RR] = 0.95, 95% confidence interval (CI) = 0.93-0.96) for women overall, and 2.3% (RR = 0.98, 95% CI = 0.96-1.00) and 5.0% per annum (RR = 0.95, 95% CI = 0.93-0.98) for men in LGAs with moderate and high densities of Medicare providers, respectively. Notification rates remained stable for men in low Medicare provider density LGAs (RR = 1.01, 95% CI = 0.96-1.07). It is likely that increased testing for chlamydia has driven increases in chlamydia notification in NSW over the last decade. Notification data provide no evidence for a general increase in the prevalence of chlamydia in the NSW community for this period. Notification-based chlamydia surveillance should be routinely adjusted for local testing rates.

  4. Hepatitis C testing and re-testing among people attending sexual health services in Australia, and hepatitis C incidence among people with human immunodeficiency virus: analysis of national sentinel surveillance data.

    PubMed

    Boettiger, David C; Law, Matthew G; Dore, Gregory J; Guy, Rebecca; Callander, Denton; Donovan, Basil; O'Connor, Catherine C; Fairley, Christopher K; Hellard, Margaret; Matthews, Gail

    2017-12-01

    Direct acting antivirals are expected to drastically reduce the burden of hepatitis C virus (HCV) in people living with Human Immunodeficiency Virus (HIV). However, rates of HCV testing, re-testing and incident infection in this group remain uncertain in Australia. We assessed trends in HCV testing, re-testing and incident infection among HIV-positive individuals, and evaluated factors associated with HCV re-testing and incident infection. The study population consisted of HIV-positive individuals who visited a sexual health service involved in the Australian Collaboration for Coordinated Enhanced Sentinel Surveillance (ACCESS) between 2007 and 2015. Poisson regression was used to assess trends and to evaluate factors associated with HCV re-testing and incident HCV infection. There were 9227 HIV-positive individuals included in our testing rate analysis. Of 3799 HIV-positive/HCV-negative people that attended an ACCESS sexual health service more than once, 2079 (54.7%) were re-tested for HCV and were therefore eligible for our incidence analysis. The rate of HCV testing increased from 17.1 to 51.4 tests per 100 patient years between 2007 and 2015 (p for trend <0.01). Over the same period, HCV re-testing rates increased from 23.9 to 79.7 tests per 100 person years (p for trend <0.01). A clear increase in testing and re-testing began after 2011. Patients who identified as men who have sex with men and those with a history of injecting drug use experienced high rates of HCV re-testing over the course of the study period. Among those who re-tested, 157 incident HCV infections occurred at a rate of 2.5 events per 100 person years. Between 2007 and 2009, 2010-2011, 2012-2013 and 2014-2015, rates of incident HCV were 0.8, 1.5, 3.9 and 2.7 events per 100 person years, respectively (p for trend <0.01). Incident HCV was strongly associated with a history of injecting drug use. High rates of HCV testing and re-testing among HIV-positive individuals in Australia will assist strategies to achieve HCV elimination through rapid treatment scale up. Continued monitoring of HCV incidence in this population is essential for guiding both HCV prevention and treatment strategies.

  5. Effects of health information exchange adoption on ambulatory testing rates

    PubMed Central

    Ross, Stephen E; Radcliff, Tiffany A; LeBlanc, William G; Dickinson, L Miriam; Libby, Anne M; Nease, Donald E

    2013-01-01

    Objective To determine the effects of the adoption of ambulatory electronic health information exchange (HIE) on rates of laboratory and radiology testing and allowable charges. Design Claims data from the dominant health plan in Mesa County, Colorado, from 1 April 2005 to 31 December 2010 were matched to HIE adoption data on the provider level. Using mixed effects regression models with the quarter as the unit of analysis, the effect of HIE adoption on testing rates and associated charges was assessed. Results Claims submitted by 306 providers in 69 practices for 34 818 patients were analyzed. The rate of testing per provider was expressed as tests per 1000 patients per quarter. For primary care providers, the rate of laboratory testing increased over the time span (baseline 1041 tests/1000 patients/quarter, increasing by 13.9 each quarter) and shifted downward with HIE adoption (downward shift of 83, p<0.01). A similar effect was found for specialist providers (baseline 718 tests/1000 patients/quarter, increasing by 19.1 each quarter, with HIE adoption associated with a downward shift of 119, p<0.01). Even so, imputed charges for laboratory tests did not shift downward significantly in either provider group, possibly due to the skewed nature of these data. For radiology testing, HIE adoption was not associated with significant changes in rates or imputed charges in either provider group. Conclusions Ambulatory HIE adoption is unlikely to produce significant direct savings through reductions in rates of testing. The economic benefits of HIE may reside instead in other downstream outcomes of better informed, higher quality care. PMID:23698257

  6. Demonstration of load rating capabilities through physical load testing : Sioux County bridge case study.

    DOT National Transportation Integrated Search

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  7. Demonstration of load rating capabilities through physical load testing : Ida County bridge case study.

    DOT National Transportation Integrated Search

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  8. Demonstration of load rating capabilities through physical load testing : Johnson County bridge case study.

    DOT National Transportation Integrated Search

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  9. Fitness for duty in the nuclear power industry: Annual summary of program performance reports CY 1994. Volume 5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westra, C.; Durbin, N.; Field, I.

    This report summarizes the data from the semiannual reports on fitness-for-duty programs submitted to the NRC by utilities for two reporting periods: January 1 through June 30, 1994, and July I through December 31, 1994. During 1994, licensees reported that they had conducted 163,241 tests for the presence of illegal drugs and alcohol. Of these tests, 1,372 (.84%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (977) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 223 positivemore » tests from random testing and 122 positive tests from for-cause testing. Follow-up testing of workers who had previously tested positive resulted in 50 positive tests. For-cause testing resulted in the highest percentage of positive tests; about 16 percent of for-cause tests were positive. This compares with a positive test rate of 1.22 percent of pre-access tests and .28 percent of random tests. The positive test rate for badged workers (including only random, for-cause, and follow-up test results) was .48 percent. Positive test rates also varied by category of worker. When all types of tests are combined (pre-access, random, for-cause, and follow-up testing), short-term contractor personnel had the highest positive test rate at 1.22 percent. Licensee employees and long-term contractors had lower combined positive test rates (.33% and .49%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (52.07%), followed by cocaine (24.25%) and alcohol (17.45%).« less

  10. Melter Throughput Enhancements for High-Iron HLW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, A. A.; Gan, Hoa; Joseph, Innocent

    2012-12-26

    This report describes work performed to develop and test new glass and feed formulations in order to increase glass melting rates in high waste loading glass formulations for HLW with high concentrations of iron. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to assess melt rate using a vertical gradient furnace system and to develop new formulations with enhanced melt rate. Testing evaluated the effects of waste loading on glass properties and themore » maximum waste loading that can be achieved. The results from crucible-scale testing supported subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass and feed formulations on waste processing rate and product quality. The DM100 was selected as the platform for these tests due to its extensive previous use in processing rate determination for various HLW streams and glass compositions.« less

  11. Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential

    NASA Technical Reports Server (NTRS)

    Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.

  12. Organizational Benchmarks for Test Utilization Performance: An Example Based on Positivity Rates for Genetic Tests.

    PubMed

    Rudolf, Joseph; Jackson, Brian R; Wilson, Andrew R; Smock, Kristi J; Schmidt, Robert L

    2017-04-01

    Health care organizations are under increasing pressure to deliver value by improving test utilization management. Many factors, including organizational factors, could affect utilization performance. Past research has focused on the impact of specific interventions in single organizations. The impact of organizational factors is unknown. The objective of this study is to determine whether testing patterns are subject to organizational effects, ie, are utilization patterns for individual tests correlated within organizations. Comparative analysis of ordering patterns (positivity rates for three genetic tests) across 659 organizations. Hierarchical regression was used to assess the impact of organizational factors after controlling for test-level factors (mutation prevalence) and hospital bed size. Test positivity rates were correlated within organizations. Organizations have a statistically significant impact on the positivity rate of three genetic tests. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  13. Does Performing Preplacement Workplace Hair Drug Testing Influence US Department of Transportation Random and Postaccident Urine Drug Test Positivity Rates?

    PubMed

    Price, James W

    Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.

  14. Differences in state drug testing and reporting by driver type in U.S. fatal traffic crashes.

    PubMed

    Slater, Megan E; Castle, I-Jen P; Logan, Barry K; Hingson, Ralph W

    2016-07-01

    Driving under the influence of drugs, including marijuana, has become more prevalent in recent years despite local, state, and federal efforts to prevent such increases. The Fatality Analysis Reporting System (FARS) is the primary source of drugged driving data for fatal crashes in the United States but lacks the completeness required to calculate unbiased estimates of drug use among drivers involved in fatal crashes. This article uses the 2013 FARS dataset to present differences in state drug testing rates by driver type, driver fault type, and state-level factors; discusses limitations related to analysis and interpretation of drugged driving data; and offers suggestions for improvements that may enable appropriate use of FARS drug testing data in the future. Results showed that state drug testing rates were highest among drivers who died at the scene of the crash (median=70.8%) and drivers who died and were at fault in the crash (median=64.4%). The lowest testing rates were seen among surviving drivers who were not transported to a hospital (median=14.0%) and surviving drivers who were not at fault in the crash (median=10.0%). Drug testing rates differed by state blood alcohol content (BAC) testing rate across all driver types and driver fault types, and in general, states that tested a higher percentage of drivers for BAC had higher drug testing rates. Testing rates might be increased through standardization and mandatory testing policies. FARS data users should continue to be cautious about the limitations of using currently available data to quantify drugged driving. More efforts are needed to improve drug testing and reporting practices, and more research is warranted to establish drug concentration levels at which driving skills become impaired. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. 77 FR 21038 - Energy Conservation Program: Test Procedures for Light-Emitting Diode Lamps

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-09

    ... Photometric Measurements of Solid-State Lighting Products'' for determining lumen output, input power, and CCT.... Test Method 5. Test Calculations and Rounding C. Proposed Approach for Rated Lifetime Measurements 1... Test Method to Project Rated Lifetime 4. Test Conditions 5. Test Setup 6. Test Method and Measurements...

  16. The Test Validation Summary

    ERIC Educational Resources Information Center

    Frederick, Richard I.; Bowden, Stephen C.

    2009-01-01

    Common rates employed in classificatory testing are the true positive rate (TPR), false positive rate (FPR), positive predictive power (PPP), and negative predictive power (NPP). FPR and TPR are estimated from research samples representing populations to be distinguished by classificatory testing. PPP and NPP are used by clinicians to classify…

  17. An Assessment of Drug Testing within the Construction Industry.

    ERIC Educational Resources Information Center

    Gerber, Jonathan K.; Yacoubian, George S., Jr.

    2002-01-01

    Investigates the efficacy of workplace drug-testing programs in reducing injury incident rates and workers' compensation experience-rating modification factors within the construction industry. Analyses indicate that companies with drug-testing programs experienced a 51 percent reduction in incident rates within two years of implementation.…

  18. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  19. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  20. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  1. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  2. Interaction of heat production, strain rate and stress power in a plastically deforming body under tensile test

    NASA Technical Reports Server (NTRS)

    Paglietti, A.

    1982-01-01

    At high strain rates the heat produced by plastic deformation can give rise to a rate dependent response even if the material has rate independent constitutive equations. This effect has to be evaluated when interpreting a material test, or else it could erroneously be ascribed to viscosity. A general thermodynamic theory of tensile testing of elastic-plastic materials is given in this paper; it is valid for large strain at finite strain rates. It enables discovery of the parameters governing the thermodynamic strain rate effect, provides a method for proper interpretation of the results of the tests of dynamic plasticity, and suggests a way of planning experiments in order to detect the real contribution of viscosity.

  3. Do celebrity endorsements matter? Observational study of BRCA gene testing and mastectomy rates after Angelina Jolie’s New York Times editorial

    PubMed Central

    Desai, Sunita

    2016-01-01

    Objective To examine the effect on BRCA testing and mastectomy rates of a widely viewed 2013 New York Times editorial by public figure Angelina Jolie that endorsed BRCA testing and announced Jolie’s decision to undergo preventive mastectomy. Design Observational study with difference-in-difference analysis. Setting Commercially insured US population. Participants Women aged 18-64 years with claims in the Truven MarketScan commercial claims database (n=9 532 836). Main outcome measures Changes in BRCA testing rates in the 15 business days before versus after 14 May 2013 (editorial date) compared with the change in the same period in 2012; mastectomy rates in the months before and after publication, both overall and within 60 days of BRCA testing among women who were tested; national estimates of incremental tests and expenditures associated with Jolie’s article in the 15 days after publication. Results Daily BRCA test rates increased immediately after the 2013 editorial, from 0.71 tests/100 000 women in the 15 business days before to 1.13 tests/100 000 women in the 15 business days after publication. In comparison, daily test rates were similar in the same period in 2012 (0.58/100 000 women in the 15 business days before 14 May versus 0.55/100 000 women in the 15 business days after), implying a difference-in-difference absolute daily increase of 0.45 tests/100 000 women or a 64% relative increase (P<0.001). The editorial was associated with an estimated increase of 4500 BRCA tests and $13.5m (£10.8m; €12.8) expenditure nationally among commercially insured adult women in those 15 days. Increased BRCA testing rates were sustained throughout 2013. Overall mastectomy rates remained unchanged in the months after publication, but 60 day mastectomy rates among women who had a BRCA test fell from 10% in the months before publication to 7% in the months after publication, suggesting that women who underwent tests as a result of to the editorial had a lower pre-test probability of having the BRCA mutation than women tested before the editorial. Conclusions Celebrity endorsements can have a large and immediate effect on use of health services. Such announcements can be a low cost means of reaching a broad audience quickly, but they may not effectively target the subpopulations that are most at risk for the relevant underlying condition. PMID:27974323

  4. Fitness for duty in the nuclear power industry. Volume 3, Annual summary of program performance reports, CY 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, T.; Westra, C.; Field, I.

    This report summarizes the data from the semi-annual reports on fitness-for-duty programs submitted to the NRC by 52 utilities for two reporting periods: January 1 through June 30, 1992, and July 1 through December 31, 1992. During 1992, licensees reported that they had conducted 266,551 tests for the presence of illegal drugs and alcohol. Of these test, 1,818 (.68%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (1,110) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 461more » positive tests from random testing and 178 positive tests from for-cause testing. Follow-up testing of workers who had previously tested positive resulted in 69 positive tests. For-cause testing resulted in the highest percentage of positive-tests; about 26% of for-cause tests were positive. This compares to a positive test rate of 1.06 percent of pre-access tests and .29 percent of random tests. Positive test rates also varied by category of worker. Overall, short-term contractor personnel had the highest positive test rate at 1.00 percent. Licensee employees and long-term contractors had lower positive test rates (.29% and .63%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (50.3%), followed by cocaine (24.8%) and alcohol (22.6%). Positive test results are also reported for NRC administrative regions and for plants located in areas with different rates of population density.« less

  5. A Robust Semi-Parametric Test for Detecting Trait-Dependent Diversification.

    PubMed

    Rabosky, Daniel L; Huang, Huateng

    2016-03-01

    Rates of species diversification vary widely across the tree of life and there is considerable interest in identifying organismal traits that correlate with rates of speciation and extinction. However, it has been challenging to develop methodological frameworks for testing hypotheses about trait-dependent diversification that are robust to phylogenetic pseudoreplication and to directionally biased rates of character change. We describe a semi-parametric test for trait-dependent diversification that explicitly requires replicated associations between character states and diversification rates to detect effects. To use the method, diversification rates are reconstructed across a phylogenetic tree with no consideration of character states. A test statistic is then computed to measure the association between species-level traits and the corresponding diversification rate estimates at the tips of the tree. The empirical value of the test statistic is compared to a null distribution that is generated by structured permutations of evolutionary rates across the phylogeny. The test is applicable to binary discrete characters as well as continuous-valued traits and can accommodate extremely sparse sampling of character states at the tips of the tree. We apply the test to several empirical data sets and demonstrate that the method has acceptable Type I error rates. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Investigating Barriers in HIV-Testing Oncology Patients: The IBITOP Study, Phase I.

    PubMed

    Merz, Laurent; Zimmermann, Stefan; Peters, Solange; Cavassini, Matthias; Darling, Katharine E A

    2016-10-01

    Although the prevalence of non-AIDS-defining cancers (non-ADCs) among people living with HIV is rising, we observed HIV testing rates below 5% at our oncology center, against a regional HIV prevalence of 0.2%-0.4%. We performed the Investigating Barriers in HIV-Testing Oncology Patients (IBITOP) study among oncology physicians and patients. Between July 1 and October 31, 2013, patients of unknown HIV status newly diagnosed with solid-organ non-ADCs referred to Lausanne University Hospital Oncology Service, Switzerland, were offered free HIV testing as part of their oncology work-up. The primary endpoints were (a) physician willingness to offer and patient acceptance of HIV testing and (b) physicians' reasons for not offering testing. Of 239 patients of unknown HIV status with a new non-ADC diagnosis, 43 (18%) were offered HIV testing, of whom 4 declined (acceptance rate: 39 of 43; 91%). Except for 21 patients tested prior to oncology consultation, 175 patients (of 239; 73%) were not offered testing. Testing rate declined among patients who were >70 years old (12% versus 30%; p = .04); no non-European patients were tested. Physicians gave reasons for not testing in 16% of cases, the main reason being patient follow-up elsewhere (10 patients; 5.7%). HIV testing during the IBITOP study increased the HIV testing rate to 18%. Although the IBITOP study increased HIV testing rates, most patients were not tested. Testing was low or nonexistent among individuals at risk of late HIV presentation (older patients and migrants). Barriers to testing appear to be physician-led, because patient acceptance of testing offered was very high (91%). In November 2013, the Swiss HIV testing recommendations were updated to propose testing in cancer patients. Phase II of the IBITOP study is examining the effect of these recommendations on HIV testing rates and focusing on physician-led testing barriers. Patients of unknown HIV status newly diagnosed with solid-organ non-AIDS-defining cancers were offered free HIV testing. Physician and patient barriers to HIV testing were examined. Most patients (82%) were not offered testing, and testing of individuals at risk of late HIV presentation (older patients and migrants) was low or nonexistent. Conversely, patient acceptance of testing offered was very high (91%), suggesting that testing barriers in this setting are physician-led. Since this study, the Swiss HIV testing recommendations now advise testing cancer patients before chemotherapy. Phase II of the Investigating Barriers in HIV-Testing Oncology Patients study is examining the effect of these recommendations on testing rates and physician barriers. ©AlphaMed Press.

  7. 40 CFR 51.352 - Basic I/M performance standard.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...

  8. 40 CFR 51.352 - Basic I/M performance standard.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...

  9. 40 CFR 51.352 - Basic I/M performance standard.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...

  10. 40 CFR 51.352 - Basic I/M performance standard.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...

  11. 40 CFR 51.352 - Basic I/M performance standard.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...

  12. Mean Abnormal Result Rate: Proof of Concept of a New Metric for Benchmarking Selectivity in Laboratory Test Ordering.

    PubMed

    Naugler, Christopher T; Guo, Maggie

    2016-04-01

    There is a need to develop and validate new metrics to access the appropriateness of laboratory test requests. The mean abnormal result rate (MARR) is a proposed measure of ordering selectivity, the premise being that higher mean abnormal rates represent more selective test ordering. As a validation of this metric, we compared the abnormal rate of lab tests with the number of tests ordered on the same requisition. We hypothesized that requisitions with larger numbers of requested tests represent less selective test ordering and therefore would have a lower overall abnormal rate. We examined 3,864,083 tests ordered on 451,895 requisitions and found that the MARR decreased from about 25% if one test was ordered to about 7% if nine or more tests were ordered, consistent with less selectivity when more tests were ordered. We then examined the MARR for community-based testing for 1,340 family physicians and found both a wide variation in MARR as well as an inverse relationship between the total tests ordered per year per physician and the physician-specific MARR. The proposed metric represents a new utilization metric for benchmarking relative selectivity of test orders among physicians. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Accelerated Testing Methodology for the Determination of Slow Crack Growth of Advanced Ceramics

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Salem, Jonathan A.; Gyekenyesi, John P.

    1997-01-01

    Constant stress-rate (dynamic fatigue) testing has been used for several decades to characterize slow crack growth behavior of glass and ceramics at both ambient and elevated temperatures. The advantage of constant stress-rate testing over other methods lies in its simplicity: Strengths are measured in a routine manner at four or more stress rates by applying a constant crosshead speed or constant loading rate. The slow crack growth parameters (n and A) required for design can be estimated from a relationship between strength and stress rate. With the proper use of preloading in constant stress-rate testing, an appreciable saving of test time can be achieved. If a preload corresponding to 50 % of the strength is applied to the specimen prior to testing, 50 % of the test time can be saved as long as the strength remains unchanged regardless of the applied preload. In fact, it has been a common, empirical practice in strength testing of ceramics or optical fibers to apply some preloading (less then 40%). The purpose of this work is to study the effect of preloading on the strength to lay a theoretical foundation on such an empirical practice. For this purpose, analytical and numerical solutions of strength as a function of preloading were developed. To verify the solution, constant stress-rate testing using glass and alumina at room temperature and alumina silicon nitride, and silicon carbide at elevated temperatures was conducted in a range of preloadings from O to 90 %.

  14. Cognitive tests predict real-world errors: the relationship between drug name confusion rates in laboratory-based memory and perception tests and corresponding error rates in large pharmacy chains.

    PubMed

    Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L

    2017-05-01

    Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Testing for variation in taxonomic extinction probabilities: a suggested methodology and some results

    USGS Publications Warehouse

    Conroy, M.J.; Nichols, J.D.

    1984-01-01

    Several important questions in evolutionary biology and paleobiology involve sources of variation in extinction rates. In all cases of which we are aware, extinction rates have been estimated from data in which the probability that an observation (e.g., a fossil taxon) will occur is related both to extinction rates and to what we term encounter probabilities. Any statistical method for analyzing fossil data should at a minimum permit separate inferences on these two components. We develop a method for estimating taxonomic extinction rates from stratigraphic range data and for testing hypotheses about variability in these rates. We use this method to estimate extinction rates and to test the hypothesis of constant extinction rates for several sets of stratigraphic range data. The results of our tests support the hypothesis that extinction rates varied over the geologic time periods examined. We also present a test that can be used to identify periods of high or low extinction probabilities and provide an example using Phanerozoic invertebrate data. Extinction rates should be analyzed using stochastic models, in which it is recognized that stratigraphic samples are random varlates and that sampling is imperfect

  16. High-rate lithium thionyl chloride cells

    NASA Technical Reports Server (NTRS)

    Goebel, F.

    1982-01-01

    A high-rate C cell with disc electrodes was developed to demonstrate current rates which are comparable to other primary systems. The tests performed established the limits of abuse beyond which the cell becomes hazardous. Tests include: impact, shock, and vibration tests; temperature cycling; and salt water immersion of fresh cells.

  17. 46 CFR 107.260 - Rated load test for cranes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...

  18. 46 CFR 107.260 - Rated load test for cranes.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...

  19. 46 CFR 107.260 - Rated load test for cranes.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...

  20. 46 CFR 107.260 - Rated load test for cranes.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...

  1. 46 CFR 107.260 - Rated load test for cranes.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...

  2. 40 CFR 63.1384 - Performance test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during any performance test...

  3. Lagoon Seepage Testing Report for Central Facilities Area (CFA) Sewage Lagoons at Idaho National Laboratory, Butte County, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Bridger

    J-U-B ENGINEERS, Inc. (J-U-B) performed seepage tests on the CFA Wastewater Lagoons 1, 2, and 3 between August 26th and September 22nd, 2014. The lagoons were tested to satisfy the Idaho Department of Environmental Quality (DEQ) Rules (IDAPA 58.01.16) that require all lagoons be tested at a frequency of every 10 years and the Compliance Activity CA-141-03 in the DEQ Wastewater Reuse Permit for the CFA Sewage Treatment Plant (LA-000141-03). The lagoons were tested to determine if the average seepage rates are less than 0.25 in/day, the maximum seepage rate allowed for lagoons built prior to April 15, 2007. Themore » average seepage rates were estimated for each lagoon and are given in Table-ES1. The average seepage rates for Lagoons 1 and 2 are less than the allowable seepage rate of 0.25 in/day. Lagoon 1 and 2 passed the seepage test and will not have to be tested again until the year 20241. However, the average seepage rate for Lagoon 3 appears to exceed the allowable seepage rate of 0.25 in/day which means the potential source for the excessive leakage should be investigated further.« less

  4. Value of the "Test & Treat" Strategy for Uninvestigated Dyspepsia at Low Prevalence Rates of Helicobacter pylori in the Population.

    PubMed

    Agréus, Lars; Talley, Nicholas J; Jones, Michael

    2016-06-01

    In populations with a low prevalence rate of Helicobacter pylori (H. pylori) infection from Western countries, guidelines for the management of uninvestigated dyspepsia generally recommend that the "test and treat" strategy should be avoided in favor of empiric proton-pump inhibitor therapy in younger patients (on average < 50 years of age) without alarm symptoms and signs. The prevalence of H. pylori infection has fallen from about 30% to about 10% in Sweden and other countries. We aimed to explore whether the rationale for test and treat is relevant in contemporary clinical practice. In settings with an infection rate in the adult population of 30% and 10%, we modeled the positive and negative predictive values for indirect (nonendoscopy) tests on current H. pylori infection with a presumed sensitivity and specificity of 95%. We then calculated the difference in false-negative and false-positive test outcome, and eradication prescription rates in the two scenarios. While the positive predictive value for the test decreased from 0.89 to 0.68 when the prevalence of H. pylori fell from 30% to 10%, there were only 1% more false-negative tests and 1% less false-positive tests. The eradication prescription rate would decrease by 18% with a 10% prevalence rate. The recommendation to stop applying "test and treat" at lower prevalence rates of H. pylori should be reconsidered. The test and treat strategy is the preferred approach for most patients who present with dyspepsia. © 2015 John Wiley & Sons Ltd.

  5. Impact of introducing near patient testing for standard investigations in general practice.

    PubMed Central

    Rink, E; Hilton, S; Szczepura, A; Fletcher, J; Sibbald, B; Davies, C; Freeling, P; Stilwell, J

    1993-01-01

    OBJECTIVE--To assess the clinical and economic impact of surgery based near patient testing in general practice for six commonly used biochemical and bacteriological tests. DESIGN--After four months' monitoring, equipment for two bacteriological and four biochemical tests was introduced without cost into 12 practices using a crossover design. Structured request forms were used to monitor laboratory investigations. SETTING--12 general practices in west midlands and south west Thames with list sizes above 9000. MAIN OUTCOME MEASURES--Investigation rates per 1000 consultations. Changes from baseline rates. Reasons for requesting investigations and provisional diagnoses. Cost per test and sensitivity of costs to rate of use. RESULTS--Investigation rates for the six tests rose by 16.5% (from 78.6/1000 consultations to 91.6/1000) when equipment was available in the surgery and reverted to baseline rates when it was withdrawn. The average weekly number of tests when equipment was available ranged from 0.5 to 10.5 (mean 9.0). Cholesterol tests were used as an addition to laboratory testing, usually for screening. Midstream urine analysis was often done in the surgery instead of in the laboratory, although 30% of samples were tested by both methods. Doctors' reasons for investigation and conditions tested were largely unaffected by availability of surgery tests. Costs for surgery tests were higher for all tests except midstream urine. CONCLUSIONS--Availability of surgery based testing increased the number of tests performed. It was cost effective only for midstream urine analysis. PMID:8219952

  6. Facility-level association of preoperative stress testing and postoperative adverse cardiac events.

    PubMed

    Valle, Javier A; Graham, Laura; Thiruvoipati, Thejasvi; Grunwald, Gary; Armstrong, Ehrin J; Maddox, Thomas M; Hawn, Mary T; Bradley, Steven M

    2018-06-22

    Despite limited indications, preoperative stress testing is often used prior to non-cardiac surgery. Patient-level analyses of stress testing and outcomes are limited by case mix and selection bias. Therefore, we sought to describe facility-level rates of preoperative stress testing for non-cardiac surgery, and to determine the association between facility-level preoperative stress testing and postoperative major adverse cardiac events (MACE). We identified patients undergoing non-cardiac surgery within 2 years of percutaneous coronary intervention in the Veterans Affairs (VA) Health Care System, from 2004 to 2011, facility-level rates of preoperative stress testing and postoperative MACE (death, myocardial infarction (MI) or revascularisation within 30 days). We determined risk-standardised facility-level rates of stress testing and postoperative MACE, and the relationship between facility-level preoperative stress testing and postoperative MACE. Among 29 937 patients undergoing non-cardiac surgery at 131 VA facilities, the median facility rate of preoperative stress testing was 13.2% (IQR 9.7%-15.9%; range 6.0%-21.5%), and 30-day postoperative MACE was 4.0% (IQR 2.4%-5.4%). After risk standardisation, the median facility-level rate of stress testing was 12.7% (IQR 8.4%-17.4%) and postoperative MACE was 3.8% (IQR 2.3%-5.6%). There was no correlation between risk-standardised stress testing and composite MACE at the facility level (r=0.022, p=0.81), or with individual outcomes of death, MI or revascularisation. In a national cohort of veterans undergoing non-cardiac surgery, we observed substantial variation in facility-level rates of preoperative stress testing. Facilities with higher rates of preoperative stress testing were not associated with better postoperative outcomes. These findings suggest an opportunity to reduce variation in preoperative stress testing without sacrificing patient outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. A boundary-optimized rejection region test for the two-sample binomial problem.

    PubMed

    Gabriel, Erin E; Nason, Martha; Fay, Michael P; Follmann, Dean A

    2018-03-30

    Testing the equality of 2 proportions for a control group versus a treatment group is a well-researched statistical problem. In some settings, there may be strong historical data that allow one to reliably expect that the control proportion is one, or nearly so. While one-sample tests or comparisons to historical controls could be used, neither can rigorously control the type I error rate in the event the true control rate changes. In this work, we propose an unconditional exact test that exploits the historical information while controlling the type I error rate. We sequentially construct a rejection region by first maximizing the rejection region in the space where all controls have an event, subject to the constraint that our type I error rate does not exceed α for any true event rate; then with any remaining α we maximize the additional rejection region in the space where one control avoids the event, and so on. When the true control event rate is one, our test is the most powerful nonrandomized test for all points in the alternative space. When the true control event rate is nearly one, we demonstrate that our test has equal or higher mean power, averaging over the alternative space, than a variety of well-known tests. For the comparison of 4 controls and 4 treated subjects, our proposed test has higher power than all comparator tests. We demonstrate the properties of our proposed test by simulation and use our method to design a malaria vaccine trial. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  8. Prospective Evaluation of the Global Earthquake Activity Rate Model (GEAR1) Earthquake Forecast: Preliminary Results

    NASA Astrophysics Data System (ADS)

    Strader, Anne; Schorlemmer, Danijel; Beutin, Thomas

    2017-04-01

    The Global Earthquake Activity Rate Model (GEAR1) is a hybrid seismicity model, constructed from a loglinear combination of smoothed seismicity from the Global Centroid Moment Tensor (CMT) earthquake catalog and geodetic strain rates (Global Strain Rate Map, version 2.1). For the 2005-2012 retrospective evaluation period, GEAR1 outperformed both parent strain rate and smoothed seismicity forecasts. Since 1. October 2015, GEAR1 has been prospectively evaluated by the Collaboratory for the Study of Earthquake Predictability (CSEP) testing center. Here, we present initial one-year test results of the GEAR1, GSRM and GSRM2.1, as well as localized evaluation of GEAR1 performance. The models were evaluated on the consistency in number (N-test), spatial (S-test) and magnitude (M-test) distribution of forecasted and observed earthquakes, as well as overall data consistency (CL-, L-tests). Performance at target earthquake locations was compared between models using the classical paired T-test and its non-parametric equivalent, the W-test, to determine if one model could be rejected in favor of another at the 0.05 significance level. For the evaluation period from 1. October 2015 to 1. October 2016, the GEAR1, GSRM and GSRM2.1 forecasts pass all CSEP likelihood tests. Comparative test results show statistically significant improvement of GEAR1 performance over both strain rate-based forecasts, both of which can be rejected in favor of GEAR1. Using point process residual analysis, we investigate the spatial distribution of differences in GEAR1, GSRM and GSRM2 model performance, to identify regions where the GEAR1 model should be adjusted, that could not be inferred from CSEP test results. Furthermore, we investigate whether the optimal combination of smoothed seismicity and strain rates remains stable over space and time.

  9. An Efficient Implementation of Fixed Failure-Rate Ratio Test for GNSS Ambiguity Resolution.

    PubMed

    Hou, Yanqing; Verhagen, Sandra; Wu, Jie

    2016-06-23

    Ambiguity Resolution (AR) plays a vital role in precise GNSS positioning. Correctly-fixed integer ambiguities can significantly improve the positioning solution, while incorrectly-fixed integer ambiguities can bring large positioning errors and, therefore, should be avoided. The ratio test is an extensively used test to validate the fixed integer ambiguities. To choose proper critical values of the ratio test, the Fixed Failure-rate Ratio Test (FFRT) has been proposed, which generates critical values according to user-defined tolerable failure rates. This contribution provides easy-to-implement fitting functions to calculate the critical values. With a massive Monte Carlo simulation, the functions for many different tolerable failure rates are provided, which enriches the choices of critical values for users. Moreover, the fitting functions for the fix rate are also provided, which for the first time allows users to evaluate the conditional success rate, i.e., the success rate once the integer candidates are accepted by FFRT. The superiority of FFRT over the traditional ratio test regarding controlling the failure rate and preventing unnecessary false alarms is shown by a simulation and a real data experiment. In the real data experiment with a baseline of 182.7 km, FFRT achieved much higher fix rates (up to 30% higher) and the same level of positioning accuracy from fixed solutions as compared to the traditional critical value.

  10. Dose Rate Effects in Linear Bipolar Transistors

    NASA Technical Reports Server (NTRS)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  11. Microelectromechanical System (MEMS) Gyroscope Noise Analysis and Scale Factor Characterization over Temperature Variation

    DTIC Science & Technology

    2016-07-01

    bias and scale factor tests. By testing state-of-the-art gyroscopes, the effect of input rate stability and accuracy may be examined. Based on the...tumble test or bias analysis at a tilted position to remove the effect of Earth’s rotation in the scale factor test • A rate table with better rate...format guide and test procedure for coriolis vibratory gyros. Piscataway (NJ): IEEE; 2004 Dec. 3. Maio A, Smith G, Knight R, Nothwang W, Conroy J

  12. 76 FR 80781 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2012

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ...-11213, Notice No. 15] RIN 2130-AA81 Alcohol and Drug Testing: Determination of Minimum Random Testing.... According to data from FRA's Management Information System, the rail industry's random drug testing [[Page... Administrator (Administrator) has therefore determined that the minimum annual random drug testing rate for the...

  13. Temporal Trends in the Utilization of Noninvasive Diagnostic Tests for Coronary Artery Disease in Ontario Between 2008 and 2014: A Population-Based Study.

    PubMed

    Roifman, Idan; Wijeysundera, Harindra C; Austin, Peter C; Maclagan, Laura C; Rezai, Mohammad R; Wright, Graham A; Tu, Jack V

    2017-02-01

    The proliferation of cardiac diagnostic tests over the past few decades has received substantial attention from policymakers. However, contemporary population-based temporal trends of the utilization of noninvasive cardiac diagnostic tests for coronary artery disease are not known. Our objective was to examine the temporal trends in the utilization of coronary computed tomography angiography (CCTA), myocardial perfusion imaging (MPI), exercise stress testing (GXT), and stress echocardiography between 2008 and 2014. We performed a population-based repeated cross-sectional study of the adult population of Ontario between January 1, 2008 and December 31, 2014. Annual utilization rates of noninvasive cardiac diagnostic tests were computed. For each cardiac testing modality, a negative binomial regression model was used to assess temporal changes in test utilization. GXT and MPI collectively accounted for 88% of all cardiac noninvasive diagnostic tests throughout our study period. Age- and sex-standardized rates of GXT declined from 26.7/1000 adult population to 21.6/1000 adult population (mean annual reduction of 3.4%; P < 0.001). MPI rates declined from 21.1/1000 adult population to 19.5/1000 adult population (mean annual reduction of 1.3%; P < 0.001). Although utilization rates for both CCTA and stress echocardiography increased over time, the combined rate of all available tests decreased from 50.8/1000 adult population to 49.1/1000 adult population (mean annual reduction of 1.1%; P < 0.001). In conclusion, utilization rates for the most prevalent noninvasive cardiac diagnostic tests-GXT and MPI-declined over our study period. Furthermore, the overall test utilization rate also declined over time. We believe our findings are encouraging from a health policy perspective. Nonetheless, rising utilization rates for CCTA and stress echocardiography will need to be monitored in the future. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Hardware test program for evaluation of baseline range/range rate sensor concept

    NASA Technical Reports Server (NTRS)

    Pernic, E.

    1985-01-01

    The test program Phase II effort provides additional design information in terms of range and range rate (R/R) sensor performance when observing and tracking a typical spacecraft target. The target used in the test program was a one-third scale model of the Hubble Space Telescope (HST) available at the MSFC test site where the tests were performed. A modified Bendix millimeter wave radar served as the R/R sensor test bed for evaluation of range and range rate tracking performance, and generation of radar signature characteristics of the spacecraft target. A summary of program test results and conclusions are presented along with detailed description of the Bendix test bed radar with accompaning instrumentation. The MSFC test site and facilities are described. The test procedures used to establish background levels, and the calibration procedures used in the range accuracy tests and RCS (radar cross section) signature measurements, are presented and a condensed version of the daily log kept during the 5 September through 17 September test period is also presented. The test program results are given starting with the RCS signature measurements, then continuing with range measurement accuracy test results and finally the range and range rate tracking accuracy test results.

  15. A New High-Speed, High-Cycle, Gear-Tooth Bending Fatigue Test Capability

    NASA Technical Reports Server (NTRS)

    Stringer, David B.; Dykas, Brian D.; LaBerge, Kelsen E.; Zakrajsek, Andrew J.; Handschuh, Robert F.

    2011-01-01

    A new high-speed test capability for determining the high cycle bending-fatigue characteristics of gear teeth has been developed. Experiments were performed in the test facility using a standard spur gear test specimens designed for use in NASA Glenn s drive system test facilities. These tests varied in load condition and cycle-rate. The cycle-rate varied from 50 to 1000 Hz. The loads varied from high-stress, low-cycle loads to near infinite life conditions. Over 100 tests were conducted using AISI 9310 steel spur gear specimen. These results were then compared to previous data in the literature for correlation. Additionally, a cycle-rate sensitivity analysis was conducted by grouping the results according to cycle-rate and comparing the data sets. Methods used to study and verify load-path and facility dynamics are also discussed.

  16. Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors.

    PubMed

    Atay, Aysenur; Demir, Leyla; Cuhadar, Serap; Saglam, Gulcan; Unal, Hulya; Aksun, Saliha; Arslan, Banu; Ozkan, Asuman; Sutcu, Recep

    2014-01-01

    Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.

  17. Sample Results from MCU Solids Outage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T.; Washington, A.; Oji, L.

    2014-09-22

    Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate;more » An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or additional details are provided below as recommendations. From this point on, IC-Anions analyses of the DSSHT should be part of the monthly routine analysis in order to spot negative trends in the oxalate leaving the MCU system. Care must be taken to monitor the oxalate content to watch for sudden precipitation of oxalate salts in the system; Conduct a study to optimize the cleaning strategy at ARP-MCU through decreasing the concentration or entirely eliminating the oxalic acid; The contents of the SSFT should remain unagitated. Routine visual observation should be maintained to ensure there is not a large buildup of solids. As water with agitation provided sufficient removal of the solids in the feed tank, it should be considered as a good means for dissolving oxalate solids if they are found in the future; Conduct a study to improve prediction of oxalate solubility in salt batch feed materials. As titanium and mercury have been found in various solids in this report, evaluate if either element plays a role in oxalate solubility during processing; Salt batch characterization focuses primarily on characterization and testing of unaltered Tank 21H material; however, non-typical feeds are developed through cleaning, washing, and/or sump transfers. As these solutions are processed through MCU, they may precipitate solids or reduce performance. Salt batch characterization and testing should be expanded to encompass a broader range of feeds that may be processed through ARPMCU.« less

  18. 7 CFR 1714.7 - Interest rate cap.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Interest rate cap. 1714.7 Section 1714.7 Agriculture... PRE-LOAN POLICIES AND PROCEDURES FOR INSURED ELECTRIC LOANS General § 1714.7 Interest rate cap. Except... section, or both the rate disparity test for the interest rate cap and the consumer income test set forth...

  19. Silicon Carbide Diodes Performance Characterization and Comparison With Silicon Devices

    NASA Technical Reports Server (NTRS)

    Lebron-Velilla, Ramon C.; Schwarze, Gene E.; Trapp, Scott

    2003-01-01

    Commercially available silicon carbide (SiC) Schottky diodes from different manufacturers were electrically tested and characterized at room temperature. Performed electrical tests include steady state forward and reverse I-V curves, as well as switching transient tests performed with the diodes operating in a hard switch dc-to-dc buck converter. The same tests were performed in current state of the art silicon (Si) and gallium arsenide (GaAs) Schottky and pn junction devices for evaluation and comparison purposes. The SiC devices tested have a voltage rating of 200, 300, and 600 V. The comparison parameters are forward voltage drop at rated current, reverse current at rated voltage and peak reverse recovery currents in the dc to dc converter. Test results show that steady state characteristics of the tested SiC devices are not superior to the best available Si Schottky and ultra fast pn junction devices. Transient tests reveal that the tested SiC Schottky devices exhibit superior transient behavior. This is more evident at the 300 and 600 V rating where SiC Schottky devices showed drastically lower reverse recovery currents than Si ultra fast pn diodes of similar rating.

  20. 40 CFR 280.104 - Local government bond rating test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Local government bond rating test. 280... STORAGE TANKS (UST) Financial Responsibility § 280.104 Local government bond rating test. (a) A general purpose local government owner or operator and/or local government serving as a guarantor may satisfy the...

  1. 21 CFR 864.6700 - Erythrocyte sedimentation rate test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...

  2. 21 CFR 864.6700 - Erythrocyte sedimentation rate test.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...

  3. 21 CFR 864.6700 - Erythrocyte sedimentation rate test.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...

  4. 21 CFR 864.6700 - Erythrocyte sedimentation rate test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...

  5. 21 CFR 864.6700 - Erythrocyte sedimentation rate test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...

  6. The optimal power puzzle: scrutiny of the monotone likelihood ratio assumption in multiple testing.

    PubMed

    Cao, Hongyuan; Sun, Wenguang; Kosorok, Michael R

    2013-01-01

    In single hypothesis testing, power is a non-decreasing function of type I error rate; hence it is desirable to test at the nominal level exactly to achieve optimal power. The puzzle lies in the fact that for multiple testing, under the false discovery rate paradigm, such a monotonic relationship may not hold. In particular, exact false discovery rate control may lead to a less powerful testing procedure if a test statistic fails to fulfil the monotone likelihood ratio condition. In this article, we identify different scenarios wherein the condition fails and give caveats for conducting multiple testing in practical settings.

  7. Reliability of psychophysiological responses across multiple motion sickness stimulation tests

    NASA Technical Reports Server (NTRS)

    Stout, C. S.; Toscano, W. B.; Cowings, P. S.

    1995-01-01

    Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.

  8. Examination of changes in pathology tests ordered by Diagnosis-Related Group (DRGs) following CPOE introduction.

    PubMed

    Vecellio, Elia; Georgiou, Andrew; Toouli, George; Eigenstetter, Alex; Li, Ling; Wilson, Roger; Westbrook, Johanna I

    2013-01-01

    Electronic test ordering, via the Electronic Medical Record (EMR), which incorporates computerised provider order entry (CPOE), is widely considered as a useful tool to support appropriate pathology test ordering. Diagnosis-related groups (DRGs) are clinically meaningful categories that allow comparisons in pathology utilisation by patient groups by controlling for many potentially confounding variables. This study used DRG data linked to pathology test data to examine changes in rates of test ordering across four years coinciding with the introduction of an EMR in six hospitals in New South Wales, Australia. This method generated a list of high pathology utilisation DRGs. We investigated patients with a Chest pain DRG to examine whether tests rates changed for specific test groups by hospital emergency department (ED) pre- and post-EMR. There was little change in testing rates between EDs or between time periods pre- and post-EMR. This is a valuable method for monitoring the impact of EMR and clinical decision support on test order rates.

  9. Modeling the Declining Positivity Rates for Human Immunodeficiency Virus Testing in New York State.

    PubMed

    Martin, Erika G; MacDonald, Roderick H; Smith, Lou C; Gordon, Daniel E; Lu, Tao; OʼConnell, Daniel A

    2015-01-01

    New York health care providers have experienced declining percentages of positive human immunodeficiency virus (HIV) tests among patients. Furthermore, observed positivity rates are lower than expected on the basis of the national estimate that one-fifth of HIV-infected residents are unaware of their infection. We used mathematical modeling to evaluate whether this decline could be a result of declining numbers of HIV-infected persons who are unaware of their infection, a measure that is impossible to measure directly. A stock-and-flow mathematical model of HIV incidence, testing, and diagnosis was developed. The model includes stocks for uninfected, infected and unaware (in 4 disease stages), and diagnosed individuals. Inputs came from published literature and time series (2006-2009) for estimated new infections, newly diagnosed HIV cases, living diagnosed cases, mortality, and diagnosis rates in New York. Primary model outcomes were the percentage of HIV-infected persons unaware of their infection and the percentage of HIV tests with a positive result (HIV positivity rate). In the base case, the estimated percentage of unaware HIV-infected persons declined from 14.2% in 2006 (range, 11.9%-16.5%) to 11.8% in 2010 (range, 9.9%-13.1%). The HIV positivity rate, assuming testing occurred independent of risk, was 0.12% in 2006 (range, 0.11%-0.15%) and 0.11% in 2010 (range, 0.10%-0.13%). The observed HIV positivity rate was more than 4 times the expected positivity rate based on the model. HIV test positivity is a readily available indicator, but it cannot distinguish causes of underlying changes. Findings suggest that the percentage of unaware HIV-infected New Yorkers is lower than the national estimate and that the observed HIV test positivity rate is greater than expected if infected and uninfected individuals tested at the same rate, indicating that testing efforts are appropriately targeting undiagnosed cases.

  10. Internet-based cohort study of HIV testing over 1 year among men who have sex with men living in England and exposed to a social marketing intervention promoting testing.

    PubMed

    Hickson, Ford; Tomlin, Keith; Hargreaves, James; Bonell, Chris; Reid, David; Weatherburn, Peter

    2015-02-01

    Increasing HIV testing among men who have sex with men (MSM) is a major policy goal in the UK. Social marketing is a common intervention to increase testing uptake. We used an online panel of MSM to examine rates of HIV testing behaviour and the impact of a social marketing intervention on them. MSM in England were recruited to a longitudinal internet panel through community websites and a previous survey. Following an enrolment survey, respondents were invited to self-complete 13 surveys at monthly intervals throughout 2011. A unique alphanumeric code linked surveys for individuals. Rates of HIV testing were compared relative to prompted recognition of a multi-part media campaign aiming to normalise HIV testing. Of 3386 unique enrolments, 2047 respondents were included in the analysis, between them submitting 15,353 monthly surveys (equivalent to 1279 years of follow-up), and recording 1517 HIV tests taken, giving an annual rate of tests per participant of 1.19 (95% CI 1.13 to 1.25). Tests were highly clustered in individuals (61% reported no test during the study). Testing rates were higher in London, single men and those aged 25-34 years. Only 7.6% recognised the intervention when prompted. After controlling for sociodemographic characteristics and exposure to other health promotion campaigns, intervention recognition was not associated with increased likelihood of testing. Higher rates of testing were strongly associated with higher number of casual sexual partners and how recently men had HIV tested before study enrolment. This social marketing intervention was not associated with increased rates of HIV testing. More effective promotion of HIV testing is needed among MSM in England to reduce the average duration of undiagnosed infection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Comparing peak and submaximal cardiorespiratory responses during field walking tests with incremental cycle ergometry in COPD.

    PubMed

    Hill, Kylie; Dolmage, Thomas E; Woon, Lynda; Coutts, Debbie; Goldstein, Roger; Brooks, Dina

    2012-02-01

    Field and laboratory-based tests are used to measure exercise capacity in people with COPD. A comparison of the cardiorespiratory responses to field tests, referenced to a laboratory test, is needed to appreciate the relative physiological demands. We sought to compare peak and submaximal cardiorespiratory responses to the 6-min walk test, incremental shuttle walk test and endurance shuttle walk test with a ramp cycle ergometer test (CET) in patients with COPD. Twenty-four participants (FEV(1) 50 ± 14%; 66.5 ± 7.7 years; 15 men) completed four sessions, separated by ≥24 h. During an individual session, participants completed either two 6-min walk tests, incremental shuttle walk tests, endurance shuttle walk tests using standardized protocols, or a single CET, wearing a portable gas analysis unit (Cosmed K4b(2)) which included measures of heart rate and arterial oxygen saturation (SpO(2)). Between tests, no difference was observed in the peak rate of oxygen uptake (F(3,69) = 1.2; P = 0.31), end-test heart rate (F(2,50) = 0.6; P = 0.58) or tidal volume (F(3,69) = 1.5; P = 0.21). Compared with all walking tests, the CET elicited a higher peak rate of carbon dioxide output (1173 ± 350 mL/min; F(3,62) = 4.8; P = 0.006), minute ventilation (48 ± 17 L/min; F(3,69) = 10.2; P < 0.001) and a higher end-test SpO(2) (95 ± 4%; F(3,63) = 24.9; P < 0.001). In patients with moderate COPD, field walking tests elicited a similar peak rate of oxygen uptake and heart rate as a CET, demonstrating that both self- and externally paced walking tests progress to high intensities. © 2011 The Authors. Respirology © 2011 Asian Pacific Society of Respirology.

  12. Advanced clinical interpretation of the Delis-Kaplan Executive Function System: multivariate base rates of low scores.

    PubMed

    Karr, Justin E; Garcia-Barrera, Mauricio A; Holdnack, James A; Iverson, Grant L

    2018-01-01

    Multivariate base rates allow for the simultaneous statistical interpretation of multiple test scores, quantifying the normal frequency of low scores on a test battery. This study provides multivariate base rates for the Delis-Kaplan Executive Function System (D-KEFS). The D-KEFS consists of 9 tests with 16 Total Achievement scores (i.e. primary indicators of executive function ability). Stratified by education and intelligence, multivariate base rates were derived for the full D-KEFS and an abbreviated four-test battery (i.e. Trail Making, Color-Word Interference, Verbal Fluency, and Tower Test) using the adult portion of the normative sample (ages 16-89). Multivariate base rates are provided for the full and four-test D-KEFS batteries, calculated using five low score cutoffs (i.e. ≤25th, 16th, 9th, 5th, and 2nd percentiles). Low scores occurred commonly among the D-KEFS normative sample, with 82.6 and 71.8% of participants obtaining at least one score ≤16th percentile for the full and four-test batteries, respectively. Intelligence and education were inversely related to low score frequency. The base rates provided herein allow clinicians to interpret multiple D-KEFS scores simultaneously for the full D-KEFS and an abbreviated battery of commonly administered tests. The use of these base rates will support clinicians when differentiating between normal variations in cognitive performance and true executive function deficits.

  13. Statistical inference methods for two crossing survival curves: a comparison of methods.

    PubMed

    Li, Huimin; Han, Dong; Hou, Yawen; Chen, Huilin; Chen, Zheng

    2015-01-01

    A common problem that is encountered in medical applications is the overall homogeneity of survival distributions when two survival curves cross each other. A survey demonstrated that under this condition, which was an obvious violation of the assumption of proportional hazard rates, the log-rank test was still used in 70% of studies. Several statistical methods have been proposed to solve this problem. However, in many applications, it is difficult to specify the types of survival differences and choose an appropriate method prior to analysis. Thus, we conducted an extensive series of Monte Carlo simulations to investigate the power and type I error rate of these procedures under various patterns of crossing survival curves with different censoring rates and distribution parameters. Our objective was to evaluate the strengths and weaknesses of tests in different situations and for various censoring rates and to recommend an appropriate test that will not fail for a wide range of applications. Simulation studies demonstrated that adaptive Neyman's smooth tests and the two-stage procedure offer higher power and greater stability than other methods when the survival distributions cross at early, middle or late times. Even for proportional hazards, both methods maintain acceptable power compared with the log-rank test. In terms of the type I error rate, Renyi and Cramér-von Mises tests are relatively conservative, whereas the statistics of the Lin-Xu test exhibit apparent inflation as the censoring rate increases. Other tests produce results close to the nominal 0.05 level. In conclusion, adaptive Neyman's smooth tests and the two-stage procedure are found to be the most stable and feasible approaches for a variety of situations and censoring rates. Therefore, they are applicable to a wider spectrum of alternatives compared with other tests.

  14. Statistical Inference Methods for Two Crossing Survival Curves: A Comparison of Methods

    PubMed Central

    Li, Huimin; Han, Dong; Hou, Yawen; Chen, Huilin; Chen, Zheng

    2015-01-01

    A common problem that is encountered in medical applications is the overall homogeneity of survival distributions when two survival curves cross each other. A survey demonstrated that under this condition, which was an obvious violation of the assumption of proportional hazard rates, the log-rank test was still used in 70% of studies. Several statistical methods have been proposed to solve this problem. However, in many applications, it is difficult to specify the types of survival differences and choose an appropriate method prior to analysis. Thus, we conducted an extensive series of Monte Carlo simulations to investigate the power and type I error rate of these procedures under various patterns of crossing survival curves with different censoring rates and distribution parameters. Our objective was to evaluate the strengths and weaknesses of tests in different situations and for various censoring rates and to recommend an appropriate test that will not fail for a wide range of applications. Simulation studies demonstrated that adaptive Neyman’s smooth tests and the two-stage procedure offer higher power and greater stability than other methods when the survival distributions cross at early, middle or late times. Even for proportional hazards, both methods maintain acceptable power compared with the log-rank test. In terms of the type I error rate, Renyi and Cramér—von Mises tests are relatively conservative, whereas the statistics of the Lin-Xu test exhibit apparent inflation as the censoring rate increases. Other tests produce results close to the nominal 0.05 level. In conclusion, adaptive Neyman’s smooth tests and the two-stage procedure are found to be the most stable and feasible approaches for a variety of situations and censoring rates. Therefore, they are applicable to a wider spectrum of alternatives compared with other tests. PMID:25615624

  15. Racial Differences in Receipt of Chlamydia Testing Among Medicaid-Insured Women in 2013.

    PubMed

    Patel, Chirag G; Chesson, Harrell W; Tao, Guoyu

    2016-03-01

    To estimate the percentage of young, sexually active Medicaid-insured women who were tested for chlamydia by age, race/ethnicity, and history of sexually transmitted disease (STD) diagnosis. We used the medical diagnostic and procedural codes from Truven Health MarketScan Medicaid claims data from 10 states in 2012 and 2013 to estimate the rates of chlamydia testing in 2013 and previous STD diagnosis (diagnosed in 2012) among Medicaid-insured women aged 15-25 years who were sexually active in 2013. We also used a logit model to assess the association between chlamydia testing and women's age, race/ethnicity, and previous STD diagnosis. Overall, among approximately 261,000 Medicaid-insured women aged 15-25 years in 2013 who were classified as sexually active, 50.2% were tested for chlamydia in 2013. The chlamydia testing rate was 45.6% for white women and 57.5% for black women. The chlamydia testing rate was 63.5% for women diagnosed as having an STD in 2012 and 46.8% for women not diagnosed as having an STD in 2012. The chlamydia testing rate was significantly (P < 0.05) associated with previous STD diagnosis, age, and race/ethnicity in our logit model. Higher chlamydia testing rates among black women can be explained in part by higher rates of previous STD diagnoses. Our finding that black women have the highest chlamydia testing rates is encouraging, as improved access to STD prevention services among racial/ethnic minorities can help to reduce racial/ethnic disparities in STDs. However, chlamydia screening remains an underused preventive health service for young women of all racial and ethnic groups.

  16. Do celebrity endorsements matter? Observational study of BRCA gene testing and mastectomy rates after Angelina Jolie's New York Times editorial.

    PubMed

    Desai, Sunita; Jena, Anupam B

    2016-12-14

     To examine the effect on BRCA testing and mastectomy rates of a widely viewed 2013 New York Times editorial by public figure Angelina Jolie that endorsed BRCA testing and announced Jolie's decision to undergo preventive mastectomy.  Observational study with difference-in-difference analysis.  Commercially insured US population.  Women aged 18-64 years with claims in the Truven MarketScan commercial claims database (n=9 532 836).  Changes in BRCA testing rates in the 15 business days before versus after 14 May 2013 (editorial date) compared with the change in the same period in 2012; mastectomy rates in the months before and after publication, both overall and within 60 days of BRCA testing among women who were tested; national estimates of incremental tests and expenditures associated with Jolie's article in the 15 days after publication.  Daily BRCA test rates increased immediately after the 2013 editorial, from 0.71 tests/100 000 women in the 15 business days before to 1.13 tests/100 000 women in the 15 business days after publication. In comparison, daily test rates were similar in the same period in 2012 (0.58/100 000 women in the 15 business days before 14 May versus 0.55/100 000 women in the 15 business days after), implying a difference-in-difference absolute daily increase of 0.45 tests/100 000 women or a 64% relative increase (P<0.001). The editorial was associated with an estimated increase of 4500 BRCA tests and $13.5m (£10.8m; €12.8) expenditure nationally among commercially insured adult women in those 15 days. Increased BRCA testing rates were sustained throughout 2013. Overall mastectomy rates remained unchanged in the months after publication, but 60 day mastectomy rates among women who had a BRCA test fell from 10% in the months before publication to 7% in the months after publication, suggesting that women who underwent tests as a result of to the editorial had a lower pre-test probability of having the BRCA mutation than women tested before the editorial.  Celebrity endorsements can have a large and immediate effect on use of health services. Such announcements can be a low cost means of reaching a broad audience quickly, but they may not effectively target the subpopulations that are most at risk for the relevant underlying condition. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Investigating Barriers in HIV-Testing Oncology Patients: The IBITOP Study, Phase I

    PubMed Central

    Merz, Laurent; Zimmermann, Stefan; Peters, Solange; Cavassini, Matthias

    2016-01-01

    Background. Although the prevalence of non-AIDS-defining cancers (non-ADCs) among people living with HIV is rising, we observed HIV testing rates below 5% at our oncology center, against a regional HIV prevalence of 0.2%–0.4%. We performed the Investigating Barriers in HIV-Testing Oncology Patients (IBITOP) study among oncology physicians and patients. Methods. Between July 1 and October 31, 2013, patients of unknown HIV status newly diagnosed with solid-organ non-ADCs referred to Lausanne University Hospital Oncology Service, Switzerland, were offered free HIV testing as part of their oncology work-up. The primary endpoints were (a) physician willingness to offer and patient acceptance of HIV testing and (b) physicians’ reasons for not offering testing. Results. Of 239 patients of unknown HIV status with a new non-ADC diagnosis, 43 (18%) were offered HIV testing, of whom 4 declined (acceptance rate: 39 of 43; 91%). Except for 21 patients tested prior to oncology consultation, 175 patients (of 239; 73%) were not offered testing. Testing rate declined among patients who were >70 years old (12% versus 30%; p = .04); no non-European patients were tested. Physicians gave reasons for not testing in 16% of cases, the main reason being patient follow-up elsewhere (10 patients; 5.7%). HIV testing during the IBITOP study increased the HIV testing rate to 18%. Conclusion. Although the IBITOP study increased HIV testing rates, most patients were not tested. Testing was low or nonexistent among individuals at risk of late HIV presentation (older patients and migrants). Barriers to testing appear to be physician-led, because patient acceptance of testing offered was very high (91%). In November 2013, the Swiss HIV testing recommendations were updated to propose testing in cancer patients. Phase II of the IBITOP study is examining the effect of these recommendations on HIV testing rates and focusing on physician-led testing barriers. Implications for Practice: Patients of unknown HIV status newly diagnosed with solid-organ non-AIDS-defining cancers were offered free HIV testing. Physician and patient barriers to HIV testing were examined. Most patients (82%) were not offered testing, and testing of individuals at risk of late HIV presentation (older patients and migrants) was low or nonexistent. Conversely, patient acceptance of testing offered was very high (91%), suggesting that testing barriers in this setting are physician-led. Since this study, the Swiss HIV testing recommendations now advise testing cancer patients before chemotherapy. Phase II of the Investigating Barriers in HIV-Testing Oncology Patients study is examining the effect of these recommendations on testing rates and physician barriers. PMID:27440062

  18. Guidelines for Design and Test of a Built-In Self Test (BIST) Circuit For Space Radiation Studies of High-Speed IC Technologies

    NASA Technical Reports Server (NTRS)

    Carts, M. A.; Marshall, P. W.; Reed, R.; Curie, S.; Randall, B.; LaBel, K.; Gilbert, B.; Daniel, E.

    2006-01-01

    Serial Bit Error Rate Testing under radiation to characterize single particle induced errors in high-speed IC technologies generally involves specialized test equipment common to the telecommunications industry. As bit rates increase, testing is complicated by the rapidly increasing cost of equipment able to test at-speed. Furthermore as rates extend into the tens of billions of bits per second test equipment ceases to be broadband, a distinct disadvantage for exploring SEE mechanisms in the target technologies. In this presentation the authors detail the testing accomplished in the CREST project and apply the knowledge gained to establish a set of guidelines suitable for designing arbitrarily high speed radiation effects tests.

  19. 49 CFR Appendix B to Part 173 - Procedure for Testing Chemical Compatibility and Rate of Permeation in Plastic Packaging and...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other..., App. B Appendix B to Part 173—Procedure for Testing Chemical Compatibility and Rate of Permeation in... °C. (64 °F.) b. Test Method 2: 28 days at a temperature no lower than 50 °C. (122 °F.) c. Test Method...

  20. Somatic and gastrointestinal in vivo biotransformation rates of hydrophobic chemicals in fish.

    PubMed

    Lo, Justin C; Campbell, David A; Kennedy, Christopher J; Gobas, Frank A P C

    2015-10-01

    To improve current bioaccumulation assessment methods, a methodology is developed, applied, and investigated for measuring in vivo biotransformation rates of hydrophobic organic substances in the body (soma) and gastrointestinal tract of the fish. The method resembles the Organisation for Economic Co-operation and Development (OECD) 305 dietary bioaccumulation test but includes reference chemicals to determine both somatic and gastrointestinal biotransformation rates of test chemicals. Somatic biotransformation rate constants for the test chemicals ranged between 0 d(-1) and 0.38 (standard error [SE] 0.03)/d(-1) . Gastrointestinal biotransformation rate constants varied from 0 d(-1) to 46 (SE 7) d(-1) . Gastrointestinal biotransformation contributed more to the overall biotransformation in fish than somatic biotransformation for all test substances but 1. Results suggest that biomagnification tests can reveal the full extent of biotransformation in fish. The common presumption that the liver is the main site of biotransformation may not apply to many substances exposed through the diet. The results suggest that the application of quantitative structure-activity relationships (QSARs) for somatic biotransformation rates and hepatic in vitro models to assess the effect of biotransformation on bioaccumulation can underestimate biotransformation rates and overestimate the biomagnification potential of chemicals that are biotransformed in the gastrointestinal tract. With some modifications, the OECD 305 test can generate somatic and gastrointestinal biotransformation data to develop biotransformation QSARs and test in vitro-in vivo biotransformation extrapolation methods. © 2015 SETAC.

  1. A Bayesian hierarchical model with novel prior specifications for estimating HIV testing rates

    PubMed Central

    An, Qian; Kang, Jian; Song, Ruiguang; Hall, H. Irene

    2016-01-01

    Human immunodeficiency virus (HIV) infection is a severe infectious disease actively spreading globally, and acquired immunodeficiency syndrome (AIDS) is an advanced stage of HIV infection. The HIV testing rate, that is, the probability that an AIDS-free HIV infected person seeks a test for HIV during a particular time interval, given no previous positive test has been obtained prior to the start of the time, is an important parameter for public health. In this paper, we propose a Bayesian hierarchical model with two levels of hierarchy to estimate the HIV testing rate using annual AIDS and AIDS-free HIV diagnoses data. At level one, we model the latent number of HIV infections for each year using a Poisson distribution with the intensity parameter representing the HIV incidence rate. At level two, the annual numbers of AIDS and AIDS-free HIV diagnosed cases and all undiagnosed cases stratified by the HIV infections at different years are modeled using a multinomial distribution with parameters including the HIV testing rate. We propose a new class of priors for the HIV incidence rate and HIV testing rate taking into account the temporal dependence of these parameters to improve the estimation accuracy. We develop an efficient posterior computation algorithm based on the adaptive rejection metropolis sampling technique. We demonstrate our model using simulation studies and the analysis of the national HIV surveillance data in the USA. PMID:26567891

  2. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  3. Test Scores, Dropout Rates, and Transfer Rates as Alternative Indicators of High School Performance

    ERIC Educational Resources Information Center

    Rumberger, Russell W.; Palardy, Gregory J.

    2005-01-01

    This study investigated the relationships among several different indicators of high school performance: test scores, dropout rates, transfer rates, and attrition rates. Hierarchical linear models were used to analyze panel data from a sample of 14,199 students who took part in the National Education Longitudinal Survey of 1988. The results…

  4. A Comparison of Validity Rates between Paper-and-Pencil and Computerized Testing with the MMPI-2

    ERIC Educational Resources Information Center

    Blazek, Nicole L.; Forbey, Johnathan D.

    2011-01-01

    Although the use of computerized testing in psychopathology assessment has increased in recent years, limited research has examined the impact of this format in terms of potential differences in test validity rates. The current study explores potential differences in the rates of valid and invalid Minnesota Multiphasic Personality Inventory--2…

  5. 10 CFR 431.264 - Uniform test method for the measurement of flow rate for commercial prerinse spray valves.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., the water consumption flow rate of commercial prerinse spray valves. (b) Testing and Calculations. The test procedure to determine the water consumption flow rate for prerinse spray valves, expressed in... the previous step. Round the final water consumption value to one decimal place as follows: (1) A...

  6. Rapid-Rate Compression Testing of Sheet Materials at High Temperatures

    NASA Technical Reports Server (NTRS)

    Bernett, E. C.; Gerberich, W. W.

    1961-01-01

    This Report describes the test equipment that was developed and the procedures that were used to evaluate structural sheet-material compression properties at preselected constant strain rates and/or loads. Electrical self-resistance was used to achieve a rapid heating rate of 200 F/sec. Four materials were tested at maximum temperatures which ranged from 600 F for the aluminum alloy to 2000 F for the Ni-Cr-Co iron-base alloy. Tests at 0.1, 0.001, and 0.00001 in./in./sec showed that strain rate has a major effect on the measured strength, especially at the high temperatures. The tests, under conditions of constant temperature and constant compression stress, showed that creep deformation can be a critical factor even when the time involved is on the order of a few seconds or less. The theoretical and practical aspects of rapid-rate compression testing are presented, and suggestions are made regarding possible modifications of the equipment which would improve the over-all capabilities.

  7. Investigation of the relationship between anxiety and heart rate variability in fibromyalgia: A new quantitative approach to evaluate anxiety level in fibromyalgia syndrome.

    PubMed

    Bilgin, Suleyman; Arslan, Evren; Elmas, Onur; Yildiz, Sedat; Colak, Omer H; Bilgin, Gurkan; Koyuncuoglu, Hasan Rifat; Akkus, Selami; Comlekci, Selcuk; Koklukaya, Etem

    2015-12-01

    Fibromyalgia syndrome (FMS) is identified by widespread musculoskeletal pain, sleep disturbance, nonrestorative sleep, fatigue, morning stiffness and anxiety. Anxiety is very common in Fibromyalgia and generally leads to a misdiagnosis. Self-rated Beck Anxiety Inventory (BAI) and doctor-rated Hamilton Anxiety Inventory (HAM-A) are frequently used by specialists to determine anxiety that accompanies fibromyalgia. However, these semi-quantitative anxiety tests are still subjective as the tests are scored using doctor-rated or self-rated scales. In this study, we investigated the relationship between heart rate variability (HRV) frequency subbands and anxiety tests. The study was conducted with 56 FMS patients and 34 healthy controls. BAI and HAM-A test scores were determined for each participant. ECG signals were then recruited and 71 HRV subbands were obtained from these ECG signals using Wavelet Packet Transform (WPT). The subbands and anxiety tests scores were analyzed and compared using multilayer perceptron neural networks (MLPNN). The results show that a HRV high frequency (HF) subband in the range of 0.15235Hz to 0.40235Hz, is correlated with BAI scores and another HRV HF subband, frequency range of 0.15235Hz to 0.28907Hz is correlated with HAM-A scores. The overall accuracy is 91.11% for HAM-A and 90% for BAI with MLPNN analysis. Doctor-rated or self-rated anxiety tests should be supported with quantitative and more objective methods. Our results show that the HRV parameters will be able to support the anxiety tests in the clinical evaluation of fibromyalgia. In other words, HRV parameters can potentially be used as an auxiliary diagnostic method in conjunction with anxiety tests. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Resistance to Soybean Aphid Among Soybean Lines, Growth-chamber Tests, 2006 Through 2008

    USDA-ARS?s Scientific Manuscript database

    We tested for resistance to the soybean aphid (SBA, Aphis glycines) among several soybean lines, and rated lines as resistant or susceptible in seven tests. The ratings of plants with respect to SBA infestation differed among lines in all tests. Kosamame (PI 171451, test II), Bhart (PI 165989, tes...

  9. Accelerated Testing Methodology Developed for Determining the Slow Crack Growth of Advanced Ceramics

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    1998-01-01

    Constant stress-rate ("dynamic fatigue") testing has been used for several decades to characterize the slow crack growth behavior of glass and structural ceramics at both ambient and elevated temperatures. The advantage of such testing over other methods lies in its simplicity: strengths are measured in a routine manner at four or more stress rates by applying a constant displacement or loading rate. The slow crack growth parameters required for component design can be estimated from a relationship between strength and stress rate. With the proper use of preloading in constant stress-rate testing, test time can be reduced appreciably. If a preload corresponding to 50 percent of the strength is applied to the specimen prior to testing, 50 percent of the test time can be saved as long as the applied preload does not change the strength. In fact, it has been a common, empirical practice in the strength testing of ceramics or optical fibers to apply some preloading (<40 percent). The purpose of this work at the NASA Lewis Research Center is to study the effect of preloading on measured strength in order to add a theoretical foundation to the empirical practice.

  10. Implementing a routine, voluntary HIV testing program in a Massachusetts county prison.

    PubMed

    Liddicoat, Rebecca V; Zheng, Hui; Internicola, Jeanne; Werner, Barbara G; Kazianis, Arthur; Golan, Yoav; Rubinstein, Eric P; Freedberg, Kenneth A; Walensky, Rochelle P

    2006-11-01

    Although U.S. prison inmates have higher rates of HIV infection than the general population, most inmates are not routinely tested for HIV infection at prison entry. The study objective was to implement a routine, voluntary HIV testing program in a Massachusetts county prison. During admission, inmates were given group HIV pre-test counseling and were subsequently offered private HIV testing. This intervention was compared to a control period during which HIV testing was provided only upon inmate or physician request. Between November 2004 and April 2005, 1,004 inmates met inclusion criteria and were offered routine, voluntary HIV testing. Of these, 734 (73.1%) accepted, 2 (0.3%) were HIV-infected, and 457 (45.5%) had been tested for HIV in the previous year. The testing rate of 73.1% was significantly increased from the rate of 18.0% (318 of 1,723) during the control period (p<0.001). Among the inmates tested for HIV in the prior year, 78.2% had received their last HIV test in the prison setting. Careful attention should be paid to prevent redundancy of testing efforts in the prison population. Implementing a routine HIV testing program among prison inmates greatly increased testing rates compared to on-request testing.

  11. Experimental investigation of time dependent behavior of welded Topopah Spring Tuff

    NASA Astrophysics Data System (ADS)

    Ma, Lumin

    Four types of laboratory tests have been performed. Specimens were attained from four lithophysal zones of the welded Topopah Spring Tuff unit at Yucca Mountain, Nevada: upper lithophysal, middle nonlithophysal, lower lithophysal and lower nonlithophysal zones. Two types of tests are conducted to study time-dependent behavior: constant strain rate and creep tests. Sixty-five specimens from the middle nonlithophysal zone were tested at six strain rates: 10-2, 10-4, 10-5, 10-6, 10-7, and 10-8 s-1. Test durations range from 2 seconds to 7 days. Fourteen specimens from middle nonlithophysal, lower lithophysal and lower nonlithophysal zones are creep tested by incremental stepwise loading. All the tests are conducted under uniaxial compression at room temperature and humidity. Specimens exhibit extremely brittle fracture and fail by axial splitting, and show very little dilatancy if any. It is assumed that microfracturing dominates the inelastic deformation and failure of the tuff. Nonlinear regression is applied to the results of the constant strain rate tests to estimate the relations between peak strength, peak axial strain, secant modulus and strain rate. All three these parameters decrease with a decrease of strain rate and follow power functions: sigmapeak = 271.37 3˙0.0212 0.0212, epsilonpeak = 0.006 3˙0.0083 , ES = 41985.4 3˙0.015 . Secant modulus is introduced mainly as a tool to analyze strain rate dependent axial strain. Two threshold stresses define creep behavior. Below about 50% of peak strength, a specimen does not creep. Above about 94% of peak strength, a specimen creeps at an accelerating rate. Between the two threshold stresses, a power law relates strain rate and stress. One hundred fifty-eight Brazilian (Indirect tensile splitting) tests have been performed at six different constant strain rates. Nineteen lithophysal specimens were tested in uniaxial compression to study their fracture pattern. These specimens have a far less brittle failure mode. They slowly crumble, collapse, and maintain considerable relative strength beyond the peak. Due to the presence of multiple relatively large lithophysal cavities, they are far weaker and softer than the nonlithophysal specimens.

  12. Biofeedback-assisted relaxation training to decrease test anxiety in nursing students.

    PubMed

    Prato, Catherine A; Yucha, Carolyn B

    2013-01-01

    Nursing students experiencing debilitating test anxiety may be unable to demonstrate their knowledge and have potential for poor academic performance. A biofeedback-assisted relaxation training program was created to reduce test anxiety. Anxiety was measured using Spielberger's Test Anxiety Inventory and monitoring peripheral skin temperature, pulse, and respiration rates during the training. Participants were introduced to diaphragmatic breathing, progressive muscle relaxation, and autogenic training. Statistically significant changes occurred in respiratory rates and skin temperatures during the diaphragmatic breathing session; respiratory rates and peripheral skin temperatures during progressive muscle relaxation session; respiratory and pulse rates, and peripheral skin temperatures during the autogenic sessions. No statistically significant difference was noted between the first and second TAI. Subjective test anxiety scores of the students did not decrease by the end of training. Autogenic training session was most effective in showing a statistically significant change in decreased respiratory and pulse rates and increased peripheral skin temperature.

  13. Relation between gastric emptying rate and energy intake in children compared with adults.

    PubMed Central

    Maes, B D; Ghoos, Y F; Geypens, B J; Hiele, M I; Rutgeerts, P J

    1995-01-01

    Measurement of gastric emptying rate of solids in children is difficult because the available methods are either invasive or induce a substantial radiation burden. In this study the newly developed 13C octanoic acid breath test was used to examine the gastric emptying rate of solids and milk in healthy children and to compare gastric emptying in children and adults. Fifteen healthy children and three groups of nine healthy adults were studied, using three different test meals labelled with 50 mg of 13C octanoic acid: a low caloric pancake (150 kcal), a high caloric pancake (250 kcal), and 210 ml of milk (134 kcal). Breath samples were taken before and at regular intervals after ingestion of the test meal, and analysed by isotope ratio mass spectrometry. The gastric emptying parameters were derived from the 13CO2 excretion curves by non-linear regression analysis. No significant difference was found between children and adults in the emptying rate of the low caloric solid test meal. In children as well as in adults, increasing the energy content of the solid meal resulted in a significantly slower emptying rate. The milk test meal, however, was emptied at a faster rate in adults and at slower rate in children compared with the low caloric solid test meal. Moreover, the emptying rate of milk in children was significantly slower than in adults. In conclusion, a similar gastric emptying rate of solids but a slower emptying of full cream milk was shown in children of school age compared with adults, using the non-radioactive 13C octanoic acid breath test. PMID:7883214

  14. Physiological and perceptual responses to incremental exercise testing in healthy men: effect of exercise test modality.

    PubMed

    Muscat, Kristina M; Kotrach, Houssam G; Wilkinson-Maitland, Courtney A; Schaeffer, Michele R; Mendonca, Cassandra T; Jensen, Dennis

    2015-11-01

    In a randomized cross-over study of 15 healthy men aged 20-30 years, we compared physiological and perceptual responses during treadmill and cycle exercise test protocols matched for increments in work rate - the source of increased locomotor muscle metabolic and contractile demands. The rates of O2 consumption and CO2 production were higher at the peak of treadmill versus cycle testing (p ≤ 0.05). Nevertheless, work rate, minute ventilation, tidal volume (VT), breathing frequency (fR), inspiratory capacity (IC), inspiratory reserve volume (IRV), tidal esophageal (Pes,tidal) and transdiaphragmatic pressure swings (Pdi,tidal), peak expiratory gastric pressures (Pga,peak), the root mean square of the diaphragm electromyogram (EMGdi,rms) expressed as a percentage of maximum EMGdi,rms (EMGdi,rms%max), and dyspnea ratings were similar at the peak of treadmill versus cycle testing (p > 0.05). Ratings of leg discomfort were higher at the peak of cycle versus treadmill exercise (p ≤ 0.05), even though peak O2 consumption was lower during cycling. Oxygen consumption, CO2 production, minute ventilation, fR, Pes,tidal, Pdi,tidal and Pga,peak were higher (p ≤ 0.05), while VT, IC, IRV, EMGdi,rms%max, and ratings of dyspnea and leg discomfort were similar (p > 0.05) at all or most submaximal work rates during treadmill versus cycle exercise. Our findings highlight important differences (and similarities) in physiological and perceptual responses at maximal and submaximal work rates during incremental treadmill and cycle exercise testing protocols. The lack of effect of exercise test modality on peak work rate advocates for the use of this readily available parameter to optimize training intensity determination, regardless of exercise training mode.

  15. Outlier removal, sum scores, and the inflation of the Type I error rate in independent samples t tests: the power of alternatives and recommendations.

    PubMed

    Bakker, Marjan; Wicherts, Jelte M

    2014-09-01

    In psychology, outliers are often excluded before running an independent samples t test, and data are often nonnormal because of the use of sum scores based on tests and questionnaires. This article concerns the handling of outliers in the context of independent samples t tests applied to nonnormal sum scores. After reviewing common practice, we present results of simulations of artificial and actual psychological data, which show that the removal of outliers based on commonly used Z value thresholds severely increases the Type I error rate. We found Type I error rates of above 20% after removing outliers with a threshold value of Z = 2 in a short and difficult test. Inflations of Type I error rates are particularly severe when researchers are given the freedom to alter threshold values of Z after having seen the effects thereof on outcomes. We recommend the use of nonparametric Mann-Whitney-Wilcoxon tests or robust Yuen-Welch tests without removing outliers. These alternatives to independent samples t tests are found to have nominal Type I error rates with a minimal loss of power when no outliers are present in the data and to have nominal Type I error rates and good power when outliers are present. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  16. Increasing chlamydia test of re-infection rates using SMS reminders and incentives.

    PubMed

    Downing, Sandra Gaye; Cashman, Colette; McNamee, Heather; Penney, Debbie; Russell, Darren B; Hellard, Margaret E

    2013-02-01

    Clients diagnosed and treated for Chlamydia trachomatis are a recognised high-risk group for subsequent infection. An estimated 8% of clients treated for chlamydia at Cairns Sexual Health Service return for re-testing within the recommended 3-4-month period. There is no recall or reminder system in place. This study assesses the effectiveness of using short messaging service (SMS) reminders with and without incentive payments to increase re-testing rates. Eligible consenting clients were randomly allocated to one of three groups. Group 1 (controls) received the standard advice from the clinician to return for re-testing in 3-4 months. Group 2 received the standard advice and an SMS reminder at 10-12 weeks post-treatment. Group 3 received the standard advice and the SMS reminder, which also offered an incentive payment on clinic attendance. 32 participants were recruited to groups 1 and 2 and 30 participants to group 3. 62 SMS reminders were sent with 13 (21.0%) reported as undelivered. Re-testing rates were 6.3%, 28.1% and 26.7% for groups 1, 2 and 3, respectively. SMS reminders with or without an incentive payment increased re-testing rates in our clients who were diagnosed and treated for chlamydia. However, re-testing remained less than ideal, and the high rate of undelivered SMS reminders suggest that this intervention alone will not achieve desired re-testing rates and that a range of strategies will be required to increase re-testing in this population.

  17. Affected sib pair tests in inbred populations.

    PubMed

    Liu, W; Weir, B S

    2004-11-01

    The affected-sib-pair (ASP) method for detecting linkage between a disease locus and marker loci was first established 50 years ago, and since then numerous modifications have been made. We modify two identity-by-state (IBS) test statistics of Lange (Lange, 1986a, 1986b) to allow for inbreeding in the population. We evaluate the power and false positive rates of the modified tests under three disease models, using simulated data. Before estimating false positive rates, we demonstrate that IBS tests are tests of both linkage and linkage disequilibrium between marker and disease loci. Therefore, the null hypothesis of IBS tests should be no linkage and no LD. When the population inbreeding coefficient is large, the false positive rates of Lange's tests become much larger than the nominal value, while those of our modified tests remain close to the nominal value. To estimate power with a controlled false positive rate, we choose the cutoff values based on simulated datasets under the null hypothesis, so that both Lange's tests and the modified tests generate same false positive rate. The powers of Lange's z-test and our modified z-test are very close and do not change much with increasing inbreeding. The power of the modified chi-square test also stays stable when the inbreeding coefficient increases. However, the power of Lange's chi-square test increases with increasing inbreeding, and is larger than that of our modified chi-square test for large inbreeding coefficients. The power is high under a recessive disease model for both Lange's tests and the modified tests, though the power is low for additive and dominant disease models. Allowing for inbreeding is therefore appropriate, at least for diseases known to be recessive.

  18. Observations on the predictive value of short-term stake tests

    Treesearch

    Stan Lebow; Bessie Woodward; Patricia Lebow

    2008-01-01

    This paper compares average ratings of test stakes after 3, 4, 5, and 7 years exposure to their subsequent ratings after 11 years. Average ratings from over 200 treatment groups exposed in plots in southern Mississippi were compared to average ratings of a reference preservative. The analysis revealed that even perfect ratings after three years were not a reliable...

  19. Certainty rating in pre-and post-tests of study modules in an online clinical pharmacy course - A pilot study to evaluate teaching and learning.

    PubMed

    Luetsch, Karen; Burrows, Judith

    2016-10-14

    Graduate and post-graduate education for health professionals is increasingly delivered in an e-learning environment, where automated, continuous formative testing with integrated feedback can guide students' self-assessment and learning. Asking students to rate the certainty they assign to the correctness of their answers to test questions can potentially provide deeper insights into the success of teaching, with test results informing course designers whether learning outcomes have been achieved. It may also have implications for decision making in clinical practice. A study of pre-and post-tests for five study modules was designed to evaluate the teaching and learning within a pharmacotherapeutic course in an online postgraduate clinical pharmacy program. Certainty based marking of multiple choice questions (MCQ) was adapted for formative pre- and post-study module testing by asking students to rate their certainty of correctness of MCQ answers. Paired t-tests and a coding scheme were used to analyse changes in answers and certainty between pre-and post-tests. A survey evaluated students' experience with the novel formative testing design. Twenty-nine pharmacists enrolled in the postgraduate program participated in the study. Overall 1315 matched pairs of MCQ answers and certainty ratings between pre- and post-module tests were available for evaluation. Most students identified correct answers in post-tests and increased their certainty compared to pre-tests. Evaluation of certainty ratings in addition to correctness of answers identified MCQs and topic areas for revision to course designers. A survey of students showed that assigning certainty ratings to their answers assisted in structuring and focusing their learning throughout online study modules, facilitating identification of areas of uncertainty and gaps in their clinical knowledge. Adding certainty ratings to MCQ answers seems to engage students with formative testing and feedback and focus their learning in a web-based postgraduate pharmacy course. It also offers deeper insight into the successful delivery of online course content, identifying areas for improvement of teaching and content delivery as well as test question design.

  20. Estimation procedures to measure and monitor failure rates of components during thermal-vacuum testing

    NASA Technical Reports Server (NTRS)

    Williams, R. E.; Kruger, R.

    1980-01-01

    Estimation procedures are described for measuring component failure rates, for comparing the failure rates of two different groups of components, and for formulating confidence intervals for testing hypotheses (based on failure rates) that the two groups perform similarly or differently. Appendix A contains an example of an analysis in which these methods are applied to investigate the characteristics of two groups of spacecraft components. The estimation procedures are adaptable to system level testing and to monitoring failure characteristics in orbit.

  1. Fuel cladding behavior under rapid loading conditions

    NASA Astrophysics Data System (ADS)

    Yueh, K.; Karlsson, J.; Stjärnsäter, J.; Schrire, D.; Ledergerber, G.; Munoz-Reja, C.; Hallstadius, L.

    2016-02-01

    A modified burst test (MBT) was used in an extensive test program to characterize fuel cladding failure behavior under rapid loading conditions. The MBT differs from a normal burst test with the use of a driver tube to simulate the expansion of a fuel pellet, thereby producing a partial strain driven deformation condition similar to that of a fuel pellet expansion in a reactivity insertion accident (RIA). A piston/cylinder assembly was used to pressurize the driver tube. By controlling the speed and distance the piston travels the loading rate and degree of sample deformation could be controlled. The use of a driver tube with a machined gauge section localizes deformation and allows for continuous monitoring of the test sample diameter change at the location of maximum hoop strain, during each test. Cladding samples from five irradiated fuel rods were tested between 296 and 553 K and loading rates from 1.5 to 3.5/s. The test rods included variations of Zircaloy-2 with different liners and ZIRLO, ranging in burn-up from 41 to 74 GWd/MTU. The test results show cladding ductility is strongly temperature and loading rate dependent. Zircaloy-2 cladding ductility degradation due to operational hydrogen pickup started to recover at approximately 358 K for test condition used in the study. This recovery temperature is strongly loading rate dependent. At 373 K, ductility recovery was small for loading rates less than 8 ms equivalent RIA pulse width, but longer than 8 ms the ductility recovery increased exponentially with increasing pulse width, consistent with literature observations of loading rate dependent brittle-to-ductile (BTD) transition temperature. The cladding ductility was also observed to be strongly loading rate/pulse width dependent for BWR cladding below the BTD temperature and Pressurized Water Reactor (PWR) cladding at both 296 and 553 K.

  2. 26 CFR 15a.453-1 - Installment method reporting for sales of real property and casual sales of personal property.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the contingent price sale agreement at a rate equal to or greater than the applicable prescribed test... stated below the applicable test rate, or interest is stated under a payment recharacterization provision... section 483 test rate, there is no internal interest under the agreement. The stated maximum selling price...

  3. Error Rates in Measuring Teacher and School Performance Based on Student Test Score Gains. NCEE 2010-4004

    ERIC Educational Resources Information Center

    Schochet, Peter Z.; Chiang, Hanley S.

    2010-01-01

    This paper addresses likely error rates for measuring teacher and school performance in the upper elementary grades using value-added models applied to student test score gain data. Using realistic performance measurement system schemes based on hypothesis testing, we develop error rate formulas based on OLS and Empirical Bayes estimators.…

  4. Highlights of the high-temperature falling particle receiver project: 2012 - 2016

    NASA Astrophysics Data System (ADS)

    Ho, C. K.; Christian, J.; Yellowhair, J.; Jeter, S.; Golob, M.; Nguyen, C.; Repole, K.; Abdel-Khalik, S.; Siegel, N.; Al-Ansary, H.; El-Leathy, A.; Gobereit, B.

    2017-06-01

    A 1 MWt continuously recirculating falling particle receiver has been demonstrated at Sandia National Laboratories. Free-fall and obstructed-flow receiver designs were tested with particle mass flow rates of ˜1 - 7 kg/s and average irradiances up to 1,000 suns. Average particle outlet temperatures exceeded 700 °C for the free-fall tests and reached nearly 800 °C for the obstructed-flow tests, with peak particle temperatures exceeding 900 °C. High particle heating rates of ˜50 to 200 °C per meter of illuminated drop length were achieved for the free-fall tests with mass flow rates ranging from 1 - 7 kg/s and for average irradiances up to ˜ 700 kW/m2. Higher temperatures were achieved at the lower particle mass flow rates due to less shading. The obstructed-flow design yielded particle heating rates over 300 °C per meter of illuminated drop length for mass flow rates of 1 - 3 kg/s for irradiances up to ˜1,000 kW/m2. The thermal efficiency was determined to be ˜60 - 70% for the free-falling particle tests and up to ˜80% for the obstructed-flow tests. Challenges encountered during the tests include particle attrition and particle loss through the aperture, reduced particle mass flow rates at high temperatures due to slot aperture narrowing and increased friction, and deterioration of the obstructed-flow structures due to wear and oxidation. Computational models were validated using the test data and will be used in future studies to design receiver configurations that can increase the thermal efficiency.

  5. Preliminary test results for Li-SOCl2 high-rate D cells

    NASA Technical Reports Server (NTRS)

    Bragg, Bobby J.; Johnson, Paul

    1992-01-01

    The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.

  6. Preliminary test results for Li-SOCl2 high-rate D cells

    NASA Astrophysics Data System (ADS)

    Bragg, Bobby J.; Johnson, Paul

    1992-02-01

    The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.

  7. Advanced Nanoindentation Testing for Studying Strain-Rate Sensitivity and Activation Volume

    NASA Astrophysics Data System (ADS)

    Maier-Kiener, Verena; Durst, Karsten

    2017-11-01

    Nanoindentation became a versatile tool for testing local mechanical properties beyond hardness and modulus. By adapting standard nanoindentation test methods, simple protocols capable of probing thermally activated deformation processes can be accomplished. Abrupt strain-rate changes within one indentation allow determining the strain-rate dependency of hardness at various indentation depths. For probing lower strain-rates and excluding thermal drift influences, long-term creep experiments can be performed by using the dynamic contact stiffness for determining the true contact area. From both procedures hardness and strain-rate, and consequently strain-rate sensitivity and activation volume can be reliably deducted within one indentation, permitting information on the locally acting thermally activated deformation mechanism. This review will first discuss various testing protocols including possible challenges and improvements. Second, it will focus on different examples showing the direct influence of crystal structure and/or microstructure on the underlying deformation behavior in pure and highly alloyed material systems.

  8. Fitness for duty in the Nuclear Power Industry. Annual summary of program performance reports CY 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westra, C.; Forslund, C.; Field, I.

    This report summarizes the data from the semiannual reports on fitness-for-duty programs submitted to the NRC by utilities for two reporting periods: January 1 through June 30, 1993, and July 1 through December 31, 1993. During 1993, licensees reported that they had conducted 242,966 tests for the presence of illegal drugs and alcohol. Of these tests, 1,512 (.62%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (952) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 341 positivemore » tests from random testing and 163 positive tests from for-cause testing. Follow-up testing of workers who had previously tested positive resulted in 56 positive tests. For-cause testing resulted in the highest percentage of positive tests; about 22 percent of for-cause tests were positive. This compares with a positive test rate of 1.04 percent of pre-access tests and .23 percent of random tests. Positive test rates also varied by category of worker. When all types of tests are combined (pre-access, random, for-cause, and follow-up testing), short-term contractor personnel had the highest positive test rate at.97 percent. Licensee employees and long-term contractors had lower combined positive test rates (.25% and .21%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (49.56%), followed by cocaine (23.41 %) and alcohol (22.65%).« less

  9. Inactivating Influenza Viruses on Surfaces Using Hydrogen Peroxide or Triethylene Glycol at Low Vapor Concentrations

    DTIC Science & Technology

    2009-04-01

    would not be expected to have a very sgnficant effect on the TEG vapor concentraton. Tests of Natural Die Off Rate. Our normal meth- odology for...to get consstent results. For tests to measure the natural de-off rate of nflu- enza vruses, ths methodology could not be used because the durat...on of the test was too long, so an alternatve procedure was employed. In preparaton for an exper- mental test to measure the natural de-off rate

  10. High-Strain-Rate Compression Testing of Ice

    NASA Technical Reports Server (NTRS)

    Shazly, Mostafa; Prakash, Vikas; Lerch, Bradley A.

    2006-01-01

    In the present study a modified split Hopkinson pressure bar (SHPB) was employed to study the effect of strain rate on the dynamic material response of ice. Disk-shaped ice specimens with flat, parallel end faces were either provided by Dartmouth College (Hanover, NH) or grown at Case Western Reserve University (Cleveland, OH). The SHPB was adapted to perform tests at high strain rates in the range 60 to 1400/s at test temperatures of -10 and -30 C. Experimental results showed that the strength of ice increases with increasing strain rates and this occurs over a change in strain rate of five orders of magnitude. Under these strain rate conditions the ice microstructure has a slight influence on the strength, but it is much less than the influence it has under quasi-static loading conditions. End constraint and frictional effects do not influence the compression tests like they do at slower strain rates, and therefore the diameter/thickness ratio of the samples is not as critical. The strength of ice at high strain rates was found to increase with decreasing test temperatures. Ice has been identified as a potential source of debris to impact the shuttle; data presented in this report can be used to validate and/or develop material models for ice impact analyses for shuttle Return to Flight efforts.

  11. Effects of normal acceleration on transient burning rate augmentation of an aluminized solid propellant

    NASA Technical Reports Server (NTRS)

    Northam, G. B.

    1972-01-01

    Instantaneous burning rate data for a polybutadiene acrylic acid propellant, containing 16 weight percent aluminum, were calculated from the pressure histories of a test motor with 96.77 sq cm of burning area and a 5.08-cm-thick propellant web. Additional acceleration tests were conducted with reduced propellant web thicknesses of 3.81, 2.54, and 1.27 cm. The metallic residue collected from the various web thickness tests was characterized by weight and shape and correlated with the instantaneous burning rate measurements. Rapid depressurization extinction tests were conducted in order that surface pitting characteristics due to localized increased burning rate could be correlated with the residue analysis and the instantaneous burning rate data. The acceleration-induced burning rate augmentation was strongly dependent on propellant distance burned, or burning time, and thus was transient in nature. The results from the extinction tests and the residue analyses indicate that the transient rate augmentation was highly dependent on local enhancement of the combustion zone heat feedback to the surface by the growth of molten residue particles on or just above the burning surface. The size, shape, and number density of molten residue particles, rather than the total residue weight, determined the acceleration-induced burning rate augmentation.

  12. Understanding High Recession Rates of Carbon Ablators Seen in Shear Tests in an Arc Jet

    NASA Technical Reports Server (NTRS)

    Driver, David M.; Olson, Michael W.; Barnhardt, Michael D.; MacLean, Matthew

    2010-01-01

    High rates of recession in arc jet shear tests of Phenolic Impregnated Carbon Ablator (PICA) inspired a series of tests and analysis on FiberForm (a carbon preform used in the fabrication of PICA). Arc jet tests were performed on FiberForm in both air and pure nitrogen for stagnation and shear configurations. The nitrogen tests showed little or no recession, while the air tests of FiberForm showed recession rates similar to that of PICA (when adjusted for the difference in density). While mechanical erosion can not be ruled out, this is the first step in doing so. Analysis using a carbon oxidation boundary condition within DPLR was used to predict the recession rate of FiberForm. The analysis indicates that much of the anomalous recession behavior seen in shear tests may simply be an artifact of the non-flight like test configuration (copper upstream of the test article) a result of dissimilar enthalpy and oxygen concentration profiles on the copper. Shape change effects were also investigated and shown to be relatively small.

  13. Association Between Direct-to-Consumer Advertising and Testosterone Testing and Initiation in the United States, 2009-2013.

    PubMed

    Layton, J Bradley; Kim, Yoonsang; Alexander, G Caleb; Emery, Sherry L

    2017-03-21

    Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. To investigate associations between televised DTCA and testosterone testing and initiation in the United States. Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009-2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004-1.008), initiation (RR, 1.007; 95% CI, 1.004-1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002-1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09-0.19), 0.05 new initiations (95% CI, 0.03-0.08), and 0.02 initiations without a recent test (95% CI, 0.01-0.03) per 10 000 men for each monthly ad exposure over the entire period. Among US men residing in the 75 designated market areas, regional exposure to televised direct-to-consumer advertising was associated with greater testosterone testing, new initiation, and initiation without recent testing.

  14. A Bayesian hierarchical model with novel prior specifications for estimating HIV testing rates.

    PubMed

    An, Qian; Kang, Jian; Song, Ruiguang; Hall, H Irene

    2016-04-30

    Human immunodeficiency virus (HIV) infection is a severe infectious disease actively spreading globally, and acquired immunodeficiency syndrome (AIDS) is an advanced stage of HIV infection. The HIV testing rate, that is, the probability that an AIDS-free HIV infected person seeks a test for HIV during a particular time interval, given no previous positive test has been obtained prior to the start of the time, is an important parameter for public health. In this paper, we propose a Bayesian hierarchical model with two levels of hierarchy to estimate the HIV testing rate using annual AIDS and AIDS-free HIV diagnoses data. At level one, we model the latent number of HIV infections for each year using a Poisson distribution with the intensity parameter representing the HIV incidence rate. At level two, the annual numbers of AIDS and AIDS-free HIV diagnosed cases and all undiagnosed cases stratified by the HIV infections at different years are modeled using a multinomial distribution with parameters including the HIV testing rate. We propose a new class of priors for the HIV incidence rate and HIV testing rate taking into account the temporal dependence of these parameters to improve the estimation accuracy. We develop an efficient posterior computation algorithm based on the adaptive rejection metropolis sampling technique. We demonstrate our model using simulation studies and the analysis of the national HIV surveillance data in the USA. Copyright © 2015 John Wiley & Sons, Ltd.

  15. SLUDGE BATCH 4 BASELINE MELT RATE FURNACE AND SLURRY-FED MELT RATE FURNACE TESTS WITH FRITS 418 AND 510 (U)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M. E.; Jones, T. M.; Miller, D. H.

    Several Slurry-Fed Melt Rate Furnace (SMRF) tests with earlier projections of the Sludge Batch 4 (SB4) composition have been performed.1,2 The first SB4 SMRF test used Frits 418 and 320, however it was found after the test that the REDuction/OXidation (REDOX) correlation at that time did not have the proper oxidation state for manganese. Because the manganese level in the SB4 sludge was higher than previous sludge batches tested, the impact of the higher manganese oxidation state was greater. The glasses were highly oxidized and very foamy, and therefore the results were inconclusive. After resolving this REDOX issue, Frits 418,more » 425, and 503 were tested in the SMRF with the updated baseline SB4 projection. Based on dry-fed Melt Rate Furnace (MRF) tests and the above mentioned SMRF tests, two previous frit recommendations were made by the Savannah River National Laboratory (SRNL) for processing of SB4 in the Defense Waste Processing Facility (DWPF). The first was Frit 503 based on the June 2006 composition projections.3 The recommendation was changed to Frit 418 as a result of the October 2006 composition projections (after the Tank 40 decant was implemented as part of the preparation plan). However, the start of SB4 processing was delayed due to the control room consolidation outage and the repair of the valve box in the Tank 51 to Tank 40 transfer line. These delays resulted in changes to the projected SB4 composition. Due to the slight change in composition and based on preliminary dry-fed MRF testing, SRNL believed that Frit 510 would increase throughput in processing SB4 in DWPF. Frit 418, which was used in processing Sludge Batch 3 (SB3), was a viable candidate and available in DWPF. Therefore, it was used during the initial SB4 processing. Due to the potential for higher melt rates with Frit 510, SMRF tests with the latest SB4 composition (1298 canisters) and Frits 510 and 418 were performed at a targeted waste loading (WL) of 35%. The '1298 canisters' describes the number of equivalent canisters that would be produced from the beginning of the current contract period before SB3 is blended with SB4. The melt rate for the SMRF SB4/Frit 510 test was 14.6 grams/minute. Due to cold cap mounding problems with the SMRF SB4/Frit 418 feed at 50 weight % solids that prevented a melt rate determination, this feed was diluted to 45 weight % solids. The melt rate for this diluted feed was 8.9 grams/minute. A correction factor of 1.2 for estimating the melt rate at 50 weight % solids from 45 weight % solids test results (based on previous SMRF testing5) was then used to estimate a melt rate of 10.7 grams/minute for SB4/Frit 418 at 50 weight % solids. Therefore, the use of Frit 510 versus Frit 418 with SB4 resulted in a higher melt rate (14.6 versus an estimated 10.7 grams/minute). For reference, a previous SMRF test with SB3/Frit 418 feed at 35% waste loading and 50 weight % solids resulted in a melt rate of 14.1 grams/minute. Therefore, depending on the actual feed rheology, the use of Frit 510 with SB4 could result in similar melt rates as experienced with SB3/Frit 418 feed in the DWPF.« less

  16. Failure Pressure and Leak Rate of Steam Generator Tubes With Stress Corrosion Cracks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majumdar, S.; Kasza, K.; Park, J.Y.

    2002-07-01

    This paper illustrates the use of an 'equivalent rectangular crack' approach to predict leak rates through laboratory generated stress corrosion cracks. A comparison between predicted and observed test data on rupture and leak rate from laboratory generated stress corrosion cracks are provided. Specimen flaws were sized by post-test fractography in addition to pre-test advanced eddy current technique. The test failure pressures and leak rates are shown to be closer to those predicted on the basis of fractography than on NDE. However, the predictions based on NDE results are encouraging, particularly because they have the potential to determine a more detailedmore » geometry of ligamentous cracks from which more accurate predictions of failure pressure and leak rate can be made in the future. (authors)« less

  17. 78 FR 41129 - Market Test of Experimental Product - International Merchandise Return Service-Non-Published Rates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-09

    ...--Non-Published Rates AGENCY: U.S. Postal Service\\TM\\. ACTION: Notice. SUMMARY: The Postal Service hereby gives notice of a market test for International Merchandise Return Service--Non-Published Rates in... Return Service (IMRS) Non-published Rate (NPR) experimental product on August 15, 2013. The Postal...

  18. 40 CFR 62.14635 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...

  19. 40 CFR 62.14635 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...

  20. 40 CFR 62.14635 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...

  1. 40 CFR 62.14635 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...

  2. 40 CFR 62.14635 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...

  3. 12 CFR 563e.28 - Assigned ratings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Assigned ratings. 563e.28 Section 563e.28 Banks... for Assessing Performance § 563e.28 Assigned ratings. (a) Ratings in general. Subject to paragraphs (b... performance under the lending, investment and service tests, the community development test, the small savings...

  4. On a problematic procedure to manipulate response biases in recognition experiments: the case of "implied" base rates.

    PubMed

    Bröder, Arndt; Malejka, Simone

    2017-07-01

    The experimental manipulation of response biases in recognition-memory tests is an important means for testing recognition models and for estimating their parameters. The textbook manipulations for binary-response formats either vary the payoff scheme or the base rate of targets in the recognition test, with the latter being the more frequently applied procedure. However, some published studies reverted to implying different base rates by instruction rather than actually changing them. Aside from unnecessarily deceiving participants, this procedure may lead to cognitive conflicts that prompt response strategies unknown to the experimenter. To test our objection, implied base rates were compared to actual base rates in a recognition experiment followed by a post-experimental interview to assess participants' response strategies. The behavioural data show that recognition-memory performance was estimated to be lower in the implied base-rate condition. The interview data demonstrate that participants used various second-order response strategies that jeopardise the interpretability of the recognition data. We thus advice researchers against substituting actual base rates with implied base rates.

  5. FINAL REPORT INTEGRATED DM1200 MELTER TESTING OF BUBBLER CONFIGURATIONS USING HLW AZ-101 SIMULANTS VSL-04R4800-4 REV 0 10/5/04

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KRUGER AA; MATLACK KS; GONG W

    2011-12-29

    This report documents melter and off-gas performance results obtained on the DM1200 HLW Pilot Melter during processing of AZ-101 HLW simulants. The tests reported herein are a subset of six tests from a larger series of tests described in the Test Plan for the work; results from the other tests have been reported separately. The solids contents of the melter feeds were based on the WTP baseline value for the solids content of the feeds from pretreatment which changed during these tests from 20% to 15% undissolved solids resulting in tests conducted at two feed solids contents. Based on themore » results of earlier tests with single outlet 'J' bubblers, initial tests were performed with a total bubbling rate of 651 pm. The first set of tests (Tests 1A-1E) addressed the effects of skewing this total air flow rate back and forth between the two installed bubblers in comparison to a fixed equal division of flow between them. The second set of tests (2A-2D) addressed the effects of bubbler depth. Subsequently, as the location, type and number of bubbling outlets were varied, the optimum bubbling rate for each was determined. A third (3A-3C) and fourth (8A-8C) set of tests evaluated the effects of alternative bubbler designs with two gas outlets per bubbler instead of one by placing four bubblers in positions simulating multiple-outlet bubblers. Data from the simulated multiple outlet bubblers were used to design bubblers with two outlets for an additional set of tests (9A-9C). Test 9 was also used to determine the effect of small sugar additions to the feed on ruthenium volatility. Another set of tests (10A-10D) evaluated the effects on production rate of spiking the feed with chloride and sulfate. Variables held constant to the extent possible included melt temperature, plenum temperature, cold cap coverage, the waste simulant composition, and the target glass composition. The feed rate was increased to the point that a constant, essentially complete, cold cap was achieved, which was used as an indicator of a maximized feed rate for each test. The first day of each test was used to build the cold cap and decrease the plenum temperature. The remainder of each test was split into two- to six-day segments, each with a different bubbling rate, bubbler orientation, or feed concentration of chloride and sulfur.« less

  6. Test Plan for SSR Antenna Rotation Rate Stabilization

    DOT National Transportation Integrated Search

    1981-10-01

    A comprehensive test plan is presented to evaluate the impact of wind and ice loading on the rotation rate stability of a Secondary Surveillance Radar (SSR) antenna used for air traffic control surveillance. Antenna rotation rate variations may intro...

  7. Special Tests for Monitoring Fetal Health

    MedlinePlus

    ... a nonstress test? The nonstress test measures the fetal heart rate in response to fetal movement over time. The ... A belt with a sensor that measures the fetal heart rate is placed around your abdomen. The fetal heart ...

  8. Failure of introduction of food allergens after negative oral food challenge tests in children.

    PubMed

    van der Valk, J P M; Gerth van Wijk, R; Vergouwe, Y; de Jong, N W

    2015-08-01

    One of the purposes to perform an oral food challenge (FC) test is to avoid unnecessary elimination of food allergens. In case of a negative FC test result, the food can be introduced. It is, however, unknown if patients act according to the outcome of the test. This study evaluates the rate of introduction of peanut, hazelnut, cow's milk or hen's egg allergens after a negative FC test. We investigated the introduction rate of children (0-18 years) with a negative FC test visiting the Department of Allergology, Erasmus Medical Centre Rotterdam from 2008 till 2013 and the factors that influence the rate of introduction. Patients were asked to complete a comprehensive questionnaire about their FC test. In total, 157 (38% girls, mean age during challenge 6.9 years) participated in the study. Of these FC tests, 104 (56%) were followed by a successful introduction, 30 (16%) by a partly introduction (traces or processed foods) and 52 (28%) by a failed introduction. Peanut and hazelnut showed a statistically significant lower successful introduction rate. Age, gender, symptoms during FC test, dietary advice and time period to introduction significantly influenced the rate of introduction. One fourth of the children with failure of introducing foods experienced symptoms during the introduction. More than one quarter of all children with a negative FC test result did not introduce the food. The FC test in its current form does not achieve its objective for this group of children.

  9. Physiologic and anti-G suit performance data from YF-16 flight tests

    NASA Technical Reports Server (NTRS)

    Gillingham, K. K.; Winter, W. R.

    1976-01-01

    Biomedical data were collected during high-G portions of 11 YF-16 test flights. Test pilots monitored revealed increased respiratory rate and volume, decreased tidal volume, and increased heart rate at higher G levels, with one pilot exhibiting various cardiac arrhythmias. Anti-G suit inflation and pressurization lags varied inversely with G-onset rate, and suit pressurization slope was near the design value.

  10. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    PubMed

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  11. Creep Strain and Strain Rate Response of 2219 Al Alloy at High Stress Levels

    NASA Technical Reports Server (NTRS)

    Taminger, Karen M. B.; Wagner, John A.; Lisagor, W. Barry

    1998-01-01

    As a result of high localized plastic deformation experienced during proof testing in an International Space Station connecting module, a study was undertaken to determine the deformation response of a 2219-T851 roll forging. After prestraining 2219-T851 Al specimens to simulate strains observed during the proof testing, creep tests were conducted in the temperature range from ambient temperature to 107 C (225 F) at stress levels approaching the ultimate tensile strength of 2219-T851 Al. Strain-time histories and strain rate responses were examined. The strain rate response was extremely high initially, but decayed rapidly, spanning as much as five orders of magnitude during primary creep. Select specimens were subjected to incremental step loading and exhibited initial creep rates of similar magnitude for each load step. Although the creep rates decreased quickly at all loads, the creep rates dropped faster and reached lower strain rate levels for lower applied loads. The initial creep rate and creep rate decay associated with primary creep were similar for specimens with and without prestrain; however, prestraining (strain hardening) the specimens, as in the aforementioned proof test, resulted in significantly longer creep life.

  12. Baroreflex modulation of muscle sympathetic nerve activity during cold pressor test in humans

    NASA Technical Reports Server (NTRS)

    Cui, Jian; Wilson, Thad E.; Crandall, Craig G.

    2002-01-01

    The purpose of this project was to test the hypothesis that baroreceptor modulation of muscle sympathetic nerve activity (MSNA) and heart rate is altered during the cold pressor test. Ten subjects were exposed to a cold pressor test by immersing a hand in ice water for 3 min while arterial blood pressure, heart rate, and MSNA were recorded. During the second and third minute of the cold pressor test, blood pressure was lowered and then raised by intravenous bolus infusions of sodium nitroprusside and phenylephrine HCl, respectively. The slope of the relationship between MSNA and diastolic blood pressure was more negative (P < 0.005) during the cold pressor test (-244.9 +/- 26.3 units x beat(-1) x mmHg(-1)) when compared with control conditions (-138.8 +/- 18.6 units x beat(-1) x mmHg(-1)), whereas no significant change in the slope of the relationship between heart rate and systolic blood pressure was observed. These data suggest that baroreceptors remain capable of modulating MSNA and heart rate during a cold pressor test; however, the sensitivity of baroreflex modulation of MSNA is elevated without altering the sensitivity of baroreflex control of heart rate.

  13. CO2 Washout Testing of the REI and EM-ACES Space Suits

    NASA Technical Reports Server (NTRS)

    Mitchell, Kathryn C.; Norcross, Jason

    2012-01-01

    When a space suit is used during ground testing, adequate carbon dioxide (CO2) washout must be provided for the suited subject. Symptoms of acute CO2 exposure depend on partial pressure of CO2 (ppCO2), metabolic rate of the subject, and other factors. This test was done to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) for a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of about 500 to 3000 BTU/hr. Supply airflow was varied between 6, 5, and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored in real time by gas analyzers with sampling tubes connected to the mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the suit air outlet. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was affected mainly by the metabolic rate of the subject: increased metabolic rate significantly (P < 0.05) increased inspired ppCO2. Decreased air flow caused small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates . 2000 BTU/hr. CO2 washout values of the EM-ACES were slightly but not significantly better than those of the REI suit. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology, and results as well as implications for future ground testing in the REI-suit and EM-ACES.

  14. Pharmaceutical container/closure integrity. II: The relationship between microbial ingress and helium leak rates in rubber-stoppered glass vials.

    PubMed

    Kirsch, L E; Nguyen, L; Moeckly, C S; Gerth, R

    1997-01-01

    Helium leak rate measurements were quantitatively correlated to the probability of microbial ingress for rubber-stoppered glass vials subjected to immersion challenge. Standard 10-mL tubing glass vials were modified by inserting micropipettes of various sizes (0.1 to 10 microns nominal diameter) into a side wall hole and securing them with epoxy. Butyl rubber closures and aluminum crimps were used to seal the vials. The test units were sealed in a helium-filled glove bag, then the absolute helium leak rates were determined. The test units were disassembled, filled with media, resealed, and autoclaved. The test units were thermally treated to eliminate airlocks within the micropipette lumen and establish a liquid path between microbial challenge media and the test units' contents. Microbial challenge was performed by immersing the test units in a 35 degrees C bath containing magnesium ion and 8 to 10 logs of viable P. diminuta and E. coli for 24 hours. The test units were then incubated at 35 degrees C for an additional 13 days. Microbial ingress was detected by turbidity and plating on blood agar. The elimination of airlocks was confirmed by the presence of magnesium ions in the vial contents by atomic absorption spectrometry. A total of 288 vials were subjected to microbial challenge testing. Those test units whose contents failed to show detectable magnesium ions were eliminated from further analysis. At large leak rates, the probability of microbial ingress approached 100% and at very low leak rates microbial ingress rates were 0%. A dramatic increase in microbial failure occurred in the leak rate region 10(-4.5) to 10(-3) std cc/sec, which roughly corresponded to leak diameters ranging from 0.4 to 2 microns. Below a leak rate of 10(-4.5) std cc/sec the microbial failure rate was < 10%. The critical leak rate in our studies, i.e. the value below which microbial ingress cannot occur because the leak is too small, was observed to be between 10(-5) and 10(-5.8) std cc/sec, which corresponds to an approximate leak diameter of 0.2-0.3 micron.

  15. Pneumatic testing in 45-degree-inclined boreholes in ash-flow tuff near Superior, Arizona

    USGS Publications Warehouse

    LeCain, G.D.

    1995-01-01

    Matrix permeability values determined by single-hole pneumatic testing in nonfractured ash-flow tuff ranged from 5.1 to 20.3 * 1046 m2 (meters squared), depending on the gas-injection rate and analysis method used. Results from the single-hole tests showed several significant correlations between permeability and injection rate and between permeability and test order. Fracture permeability values determined by cross-hole pneumatic testing in fractured ash-flow tuff ranged from 0.81 to 3.49 * 1044 m2, depending on injection rate and analysis method used. Results from the cross-hole tests monitor intervals showed no significant correlation between permeability and injection rate; however, results from the injection interval showed a significant correlation between injection rate and permeability. Porosity estimates from the 'cross-hole testing range from 0.8 to 2.0 percent. The maximum temperature change associated with the pneumatic testing was 1.2'(2 measured in the injection interval during cross-hole testing. The maximum temperature change in the guard and monitor intervals was O.Ip C. The maximum error introduced into the permeability values due to temperature fluctuations is approximately 4 percent. Data from temperature monitoring in the borehole indicated a positive correlation between the temperature decrease in the injection interval during recovery testing and the gas-injection rate. The thermocouple psychrometers indicated that water vapor was condensing in the boreholes during testing. The psychrometers in the guard and monitor intervals detected the drier injected gas as an increase in the dry bulb reading. The relative humidity in the test intervals was always higher than the upper measurement limit of the psychrometers. Although the installation of the packer system may have altered the water balance of the borehole, the gas-injection testing resulted in minimal or no changes in the borehole relative humidity.

  16. Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.

    PubMed

    Stern, C H; Jaasma, D R; Champion, M R

    1993-03-01

    A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.

  17. Are elite cricketers more prone to suicide? A psychological autopsy study of Test cricketer suicides.

    PubMed

    Shah, Ajit; Sava-Shah, Shrenik; Wijeratne, Chanaka; Draper, Brian

    2016-06-01

    It has been hypothesised that the very nature of the game predisposes elite cricketers to higher rates of suicide. We aim to estimate the suicide rate of male Test cricketers and to determine the reasons for suicide. The suicide rate in male Test cricketers was determined. A psychological autopsy was conducted using published biographical data. Twenty suicides amongst 2794 male Test cricketers from 1877 to 2014 yielded a suicide rate of 715.4 per 100,000 for that period. Health, financial and relationship issues were prominent; depression and alcohol misuse were common. Most suicides in Test cricketers occurred post-retirement in mid to late life with similar correlates to those found in the general male population. The idiosyncrasies of cricket are unlikely to contribute to suicide; however, the post-retirement welfare of Test cricketers should remain a focus of concern and the greater supports available to contemporary Test cricketers needs to extend beyond retirement. © The Royal Australian and New Zealand College of Psychiatrists 2016.

  18. Verification of International Space Station Component Leak Rates by Helium Accumulation Method

    NASA Technical Reports Server (NTRS)

    Underwood, Steve D.; Smith, Sherry L.

    2003-01-01

    Discovery of leakage on several International Space Station U.S. Laboratory Module ammonia system quick disconnects (QDs) led to the need for a process to quantify total leakage without removing the QDs from the system. An innovative solution was proposed allowing quantitative leak rate measurement at ambient external pressure without QD removal. The method utilizes a helium mass spectrometer configured in the detector probe mode to determine helium leak rates inside a containment hood installed on the test component. The method was validated through extensive developmental testing. Test results showed the method was viable, accurate and repeatable for a wide range of leak rates. The accumulation method has been accepted by NASA and is currently being used by Boeing Huntsville, Boeing Kennedy Space Center and Boeing Johnson Space Center to test welds and valves and will be used by Alenia to test the Cupola. The method has been used in place of more expensive vacuum chamber testing which requires removing the test component from the system.

  19. Technology diffusion and diagnostic testing for prostate cancer

    PubMed Central

    Schroeck, Florian R.; Kaufman, Samuel R.; Jacobs, Bruce L.; Skolarus, Ted A.; Miller, David C.; Weizer, Alon Z.; Montgomery, Jeffrey S.; Wei, John T.; Shahinian, Vahakn B.; Hollenbeck, Brent K.

    2013-01-01

    Purpose While the dissemination of robotic prostatectomy and intensity-modulated radiotherapy (IMRT) may fuel increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with receipt of prostate specific antigen (PSA) testing and prostate biopsy. Methods In this retrospective cohort study, we included 117,857 men age 66 and older from the 5% sample of Medicare beneficiaries living in the Surveillance Epidemiology and End Results (SEER) areas from 2003 – 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or IMRT per population in a healthcare market (i.e., hospital referral region). We assessed the association of technology penetration with rates of PSA testing and prostate biopsy with generalized estimating equations. Results High technology penetration was associated with increased rates of PSA testing (442 versus 425 per 1,000 person-years, p<0.01) and similar rates of prostate biopsy (10.1 versus 9.9 per 1,000 person-years, p=0.69). The impact of technology penetration on PSA testing and prostate biopsy was much smaller than the effect of age, race, and comorbidity (e.g., PSA testing rate per 1,000 person-years: 485 versus 373 for men with only one versus 3+ co-morbid conditions, p<0.01). Conclusions Increased technology penetration was associated with slightly higher rates of PSA testing and no change in prostate biopsy rates. Collectively, our findings temper concerns that adoption of new technology accelerates diagnostic testing for prostate cancer. PMID:23669564

  20. Expanded HIV Testing in the US Department of Veterans Affairs, 2009–2011

    PubMed Central

    Halloran, CNS, James; Pedati, Caitlin; Dursa, Erin K.; Durfee, Janet; Martinello, Richard; Davey, Victoria; Ross, David

    2013-01-01

    Objectives. We measured HIV testing and seropositivity among veterans in Veterans Affairs (VA) care for calendar years 2009 through 2011 and analyzed 2011 results by patient demographics. Methods. We performed a repeated-measures cross-sectional study using standardized electronic data extraction from the VA electronic health records for all veterans with at least 1 outpatient visit during 2009 through 2011. We analyzed testing rates and seropositivity by demographic characteristics for 2011. Results. Of veterans with an outpatient visit, 20.0% had an HIV test in 2011, compared with 9.2% in 2009. Documented HIV testing rates were highest in women and Blacks. Of confirmed positive test results, 67.0% were in outpatients older than 50 years. Seropositivity was highest among men aged 30 to 49 years, women aged 50 to 69 years, and Black outpatients of both genders. Implementation of an electronic clinical reminder was associated with higher testing rates. Conclusions. The significant effect of an electronic clinical reminder suggests that such decision support tools can substantially increase testing rates. The frequency of positive test results in older individuals suggests the need for additional work to define optimum approaches to HIV testing in this population. PMID:24134344

  1. 105-KE Isolation Barrier Leak Rate Acceptance Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCracken, K.J.

    1995-06-14

    This Acceptance Test Report (ATR) contains the completed and signed Acceptance Procedure (ATP) for the 105-KE Isolations Barrier Leak Rate Test. The Test Engineer`s log, the completed sections of the ATP in the Appendix for Repeat Testing (Appendix K), the approved WHC J-7s (Appendix H), the data logger files (Appendices T and U), and the post test calibration checks (Appendix V) are included.

  2. Comparisons of false negative rates from a trend test alone and from a trend test jointly with a control-high groups pairwise test in the determination of the carcinogenicity of new drugs.

    PubMed

    Lin, Karl K; Rahman, Mohammad A

    2018-05-21

    Interest has been expressed in using a joint test procedure that requires that the results of both a trend test and a pairwise comparison test between the control and the high groups be statistically significant simultaneously at the levels of significance recommended in the FDA 2001 draft guidance for industry document for the separate tests in order for the drug effect on the development of an individual tumor type to be considered as statistically significant. Results of our simulation studies show that there is a serious consequence of large inflations of the false negative rate through large decreases of false positive rate in the use of the above joint test procedure in the final interpretation of the carcinogenicity potential of a new drug if the levels of significance recommended for separate tests are used. The inflation can be as high as 204.5% of the false negative rate when the trend test alone is required to test if the effect is statistically significant. To correct the problem, new sets of levels of significance have also been developed for those who want to use the joint test in reviews of carcinogenicity studies.

  3. In vitro dynamic solubility test: influence of various parameters.

    PubMed Central

    Thélohan, S; de Meringo, A

    1994-01-01

    This article discusses the dissolution of mineral fibers in simulated physiological fluids (SPF), and the parameters that affect the solubility measurement in a dynamic test where an SPF runs through a cell containing fibers (Scholze and Conradt test). Solutions simulate either the extracellular fluid (pH 7.6) or the intracellular fluid (pH 4.5). The fibers have various chemical compositions and are either continuously drawn or processed as wool. The fiber solubility is determined by the amount of SiO2 (and occasionally other ions) released in the solution. Results are stated as percentage of the initial silica content released or as dissolution rate v in nm/day. The reproducibility of the test is higher with the less soluble fibers (10% solubility), than with highly soluble fibers (20% solubility). The influence of test parameters, including SPF, test duration, and surface area/volume (SA/V), has been studied. The pH and the inorganic buffer salts have a major influence: industrial glasswool composition is soluble at pH 7.6 but not at pH 4.5. The opposite is true for rock- (basalt) wool composition. For slightly soluble fibers, the dissolution rate v remains constant with time, whereas for highly soluble fibers, the dissolution rate decreases rapidly. The dissolution rates believed to occur are v1, initial dissolution rate, and v2, dissolution rate of the residual fibers. The SA of fibers varies with the mass of the fibers tested, or with the fiber diameter at equal mass. Volume, V, is the chosen flow rate. An increase in the SA/V ratio leads to a decrease in the dissolution rate.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7882964

  4. In vitro dynamic solubility test: influence of various parameters.

    PubMed

    Thélohan, S; de Meringo, A

    1994-10-01

    This article discusses the dissolution of mineral fibers in simulated physiological fluids (SPF), and the parameters that affect the solubility measurement in a dynamic test where an SPF runs through a cell containing fibers (Scholze and Conradt test). Solutions simulate either the extracellular fluid (pH 7.6) or the intracellular fluid (pH 4.5). The fibers have various chemical compositions and are either continuously drawn or processed as wool. The fiber solubility is determined by the amount of SiO2 (and occasionally other ions) released in the solution. Results are stated as percentage of the initial silica content released or as dissolution rate v in nm/day. The reproducibility of the test is higher with the less soluble fibers (10% solubility), than with highly soluble fibers (20% solubility). The influence of test parameters, including SPF, test duration, and surface area/volume (SA/V), has been studied. The pH and the inorganic buffer salts have a major influence: industrial glasswool composition is soluble at pH 7.6 but not at pH 4.5. The opposite is true for rock- (basalt) wool composition. For slightly soluble fibers, the dissolution rate v remains constant with time, whereas for highly soluble fibers, the dissolution rate decreases rapidly. The dissolution rates believed to occur are v1, initial dissolution rate, and v2, dissolution rate of the residual fibers. The SA of fibers varies with the mass of the fibers tested, or with the fiber diameter at equal mass. Volume, V, is the chosen flow rate. An increase in the SA/V ratio leads to a decrease in the dissolution rate.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Comparison of denitrification activity measurements in groundwater using cores and natural-gradient tracer tests

    USGS Publications Warehouse

    Smith, R.L.; Garabedian, S.P.; Brooks, M.H.

    1996-01-01

    The transport of many solutes in groundwater is dependent upon the relative rates of physical flow and microbial metabolism. Quantifying rates of microbial processes under subsurface conditions is difficult and is most commonly approximated using laboratory studies with aquifer materials. In this study, we measured in situ rates of denitrification in a nitrate- contaminated aquifer using small-scale, natural-gradient tracer tests and compared the results with rates obtained from laboratory incubations with aquifer core material. Activity was measured using the acetylene block technique. For the tracer tests, co-injection of acetylene and bromide into the aquifer produced a 30 ??M increase in nitrous oxide after 10 m of transport (23-30 days). An advection-dispersion transport model was modified to include an acetylene-dependent nitrous oxide production term and used to simulate the tracer breakthrough curves. The model required a 4-day lag period and a relatively low sensitivity to acetylene to match the narrow nitrous oxide breakthrough curves. Estimates of in situ denitrification rates were 0.60 and 1.51 nmol of N2O produced cm-3 aquifer day-1 for two successive tests. Aquifer core material collected from the tracer test site and incubated as mixed slurries in flasks and as intact cores yielded rates that were 1.2-26 times higher than the tracer test rate estimates. Results with the coring-dependent techniques were variable and subject to the small- scale heterogeneity within the aquifer, while the tracer tests integrated the heterogeneity along a flow path, giving a rate estimate that is more applicable to transport at the scale of the aquifer.

  6. Evaluation of sulfate reduction at experimentally induced mixing interfaces using small-scale push-pull tests in an aquifer-wetland system

    USGS Publications Warehouse

    Kneeshaw, T.A.; McGuire, J.T.; Smith, E.W.; Cozzarelli, I.M.

    2007-01-01

    This paper presents small-scale push-pull tests designed to evaluate the kinetic controls on SO42 - reduction in situ at mixing interfaces between a wetland and aquifer impacted by landfill leachate at the Norman Landfill research site, Norman, OK. Quantifying the rates of redox reactions initiated at interfaces is of great interest because interfaces have been shown to be zones of increased biogeochemical transformations and thus may play an important role in natural attenuation. To mimic the aquifer-wetland interface and evaluate reaction rates, SO42 --rich anaerobic aquifer water (??? 100 mg / L SO42 -) was introduced into SO42 --depleted wetland porewater via push-pull tests. Results showed SO42 - reduction was stimulated by the mixing of these waters and first-order rate coefficients were comparable to those measured in other push-pull studies. However, rate data were complex involving either multiple first-order rate coefficients or a more complex rate order. In addition, a lag phase was observed prior to SO42 - reduction that persisted until the mixing interface between test solution and native water was recovered, irrespective of temporal and spatial constraints. The lag phase was not eliminated by the addition of electron donor (acetate) to the injected test solution. Subsequent push-pull tests designed to elucidate the nature of the lag phase support the importance of the mixing interface in controlling terminal electron accepting processes. These data suggest redox reactions may occur rapidly at the mixing interface between injected and native waters but not in the injected bulk water mass. Under these circumstances, push-pull test data should be evaluated to ensure the apparent rate is actually a function of time and that complexities in rate data be considered. ?? 2007 Elsevier Ltd. All rights reserved.

  7. Single neuropsychological test scores associated with rate of cognitive decline in early Alzheimer disease.

    PubMed

    Parikh, Mili; Hynan, Linda S; Weiner, Myron F; Lacritz, Laura; Ringe, Wendy; Cullum, C Munro

    2014-01-01

    Alzheimer disease (AD) characteristically begins with episodic memory impairment followed by other cognitive deficits; however, the course of illness varies, with substantial differences in the rate of cognitive decline. For research and clinical purposes it would be useful to distinguish between persons who will progress slowly from persons who will progress at an average or faster rate. Our objective was to use neurocognitive performance features and disease-specific and health information to determine a predictive model for the rate of cognitive decline in participants with mild AD. We reviewed the records of a series of 96 consecutive participants with mild AD from 1995 to 2011 who had been administered selected neurocognitive tests and clinical measures. Based on Clinical Dementia Rating (CDR) of functional and cognitive decline over 2 years, participants were classified as Faster (n = 45) or Slower (n = 51) Progressors. Stepwise logistic regression analyses using neurocognitive performance features, disease-specific, health, and demographic variables were performed. Neuropsychological scores that distinguished Faster from Slower Progressors included Trail Making Test - A, Digit Symbol, and California Verbal Learning Test (CVLT) Total Learned and Primacy Recall. No disease-specific, health, or demographic variable predicted rate of progression; however, history of heart disease showed a trend. Among the neuropsychological variables, Trail Making Test - A best distinguished Faster from Slower Progressors, with an overall accuracy of 68%. In an omnibus model including neuropsychological, disease-specific, health, and demographic variables, only Trail Making Test - A distinguished between groups. Several neuropsychological performance features were associated with the rate of cognitive decline in mild AD, with baseline Trail Making Test - A performance best separating those who declined at an average or faster rate from those who showed slower progression.

  8. Multiple hypotheses testing based on ordered p values--a historical survey with applications to medical research.

    PubMed

    Hommel, Gerhard; Bretz, Frank; Maurer, Willi

    2011-07-01

    Global tests and multiple test procedures are often based on ordered p values. Such procedures are available for arbitrary dependence structures as well as for specific dependence assumptions of the test statistics. Most of these procedures have been considered as global tests. Multiple test procedures can be obtained by applying the closure principle in order to control the familywise error rate, or by using the false discovery rate as a criterion for type I error rate control. We provide an overview and present examples showing the importance of these procedures in medical research. Finally, we discuss modifications when different weights for the hypotheses of interest are chosen.

  9. Investigation of creep by use of closed loop servo-hydraulic test system

    NASA Technical Reports Server (NTRS)

    Wu, H. C.; Yao, J. C.

    1981-01-01

    Creep tests were conducted by means of a closed loop servo-controlled materials test system. These tests are different from the conventional creep tests in that the strain history prior to creep may be carefully monitored. Tests were performed for aluminum alloy 6061-0 at 150 C and monitored by a PDP 11/04 minicomputer at a preset constant plastic-strain rate prehistory. The results show that the plastic-strain rate prior to creep plays a significant role in creep behavior. The endochronic theory of viscoplasticity was applied to describe the observed creep curves. The concepts of intrinsic time and strain rate sensitivity function are employed and modified according to the present observation.

  10. HIV Testing and Diagnosis Rates in Kiev, Ukraine: April 2013-March 2014.

    PubMed

    Simmons, Ruth; Malyuta, Ruslan; Chentsova, Nelli; Medoeva, Antonia; Kruglov, Yuri; Yurchenko, Alexander; Copas, Andrew; Porter, Kholoud

    2015-01-01

    Data from Ukraine on risk factors for HIV acquisition are limited. We describe the characteristics of individuals testing for HIV in the main testing centres of the Ukrainian capital Kiev, including HIV risk factors, testing rates, and positivity rates. As part of a larger study to estimate HIV incidence within Kiev City, we included questions on possible risk factors for HIV acquisition and testing history to existing systems in 4 infectious disease clinics. Data were provided by the person requesting an HIV test using a handheld electronic tablet. All persons (≥16 yrs) presenting for an HIV test April 2013-March 2014 were included. Rates per 100,000 were calculated using region-specific denominators for Kiev. During the study period 6370 individuals tested for HIV, equivalent to a testing rate of 293.2 per 100,000. Of these, 467 (7.8%) were HIV-positive, with the highest proportion positive among 31-35 year olds (11.2%), males (9.4%), people who inject drugs (PWID) (17.9%) and men who have sex with men (MSM) (24.1%). Using published population size estimates of MSM, diagnosis rates for MSM ranged from 490.6 to 1548.3/100,000. A higher proportion of heterosexual women compared to heterosexual men reported contact with PWID, (16% vs. 4.7%) suggesting a bridging in risk between PWID and their sexual partners. Collection of HIV risk factor information in Kiev, essential for the purposes of developing effective HIV prevention and response tools, is feasible. The high percentage of MSM among those testing positive for HIV, may indicate a significant level of undisclosed sex between men in national figures.

  11. Preloading To Accelerate Slow-Crack-Growth Testing

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, John P.; Choi, Sung R.; Pawlik, Ralph J.

    2004-01-01

    An accelerated-testing methodology has been developed for measuring the slow-crack-growth (SCG) behavior of brittle materials. Like the prior methodology, the accelerated-testing methodology involves dynamic fatigue ( constant stress-rate) testing, in which a load or a displacement is applied to a specimen at a constant rate. SCG parameters or life prediction parameters needed for designing components made of the same material as that of the specimen are calculated from the relationship between (1) the strength of the material as measured in the test and (2) the applied stress rate used in the test. Despite its simplicity and convenience, dynamic fatigue testing as practiced heretofore has one major drawback: it is extremely time-consuming, especially at low stress rates. The present accelerated methodology reduces the time needed to test a specimen at a given rate of applied load, stress, or displacement. Instead of starting the test from zero applied load or displacement as in the prior methodology, one preloads the specimen and increases the applied load at the specified rate (see Figure 1). One might expect the preload to alter the results of the test and indeed it does, but fortunately, it is possible to account for the effect of the preload in interpreting the results. The accounting is done by calculating the normalized strength (defined as the strength in the presence of preload the strength in the absence of preload) as a function of (1) the preloading factor (defined as the preload stress the strength in the absence of preload) and (2) a SCG parameter, denoted n, that is used in a power-law crack-speed formulation. Figure 2 presents numerical results from this theoretical calculation.

  12. HIV Testing and Diagnosis Rates in Kiev, Ukraine: April 2013 - March 2014

    PubMed Central

    Simmons, Ruth; Malyuta, Ruslan; Medoeva, Antonia; Kruglov, Yuri; Yurchenko, Alexander; Copas, Andrew; Porter, Kholoud

    2015-01-01

    Objective Data from Ukraine on risk factors for HIV acquisition are limited. We describe the characteristics of individuals testing for HIV in the main testing centres of the Ukrainian capital Kiev, including HIV risk factors, testing rates, and positivity rates. Methods As part of a larger study to estimate HIV incidence within Kiev City, we included questions on possible risk factors for HIV acquisition and testing history to existing systems in 4 infectious disease clinics. Data were provided by the person requesting an HIV test using a handheld electronic tablet. All persons (≥16yrs) presenting for an HIV test April 2013–March 2014 were included. Rates per 100,000 were calculated using region-specific denominators for Kiev. Results During the study period 6370 individuals tested for HIV, equivalent to a testing rate of 293.2 per 100,000. Of these, 467 (7.8%) were HIV-positive, with the highest proportion positive among 31–35 year olds (11.2%), males (9.4%), people who inject drugs (PWID) (17.9%) and men who have sex with men (MSM) (24.1%). Using published population size estimates of MSM, diagnosis rates for MSM ranged from 490.6to 1548.3/100,000. A higher proportion of heterosexual women compared to heterosexual men reported contact with PWID, (16% vs. 4.7%) suggesting a bridging in risk between PWID and their sexual partners. Conclusion Collection of HIV risk factor information in Kiev, essential for the purposes of developing effective HIV prevention and response tools, is feasible. The high percentage of MSM among those testing positive for HIV, may indicate a significant level of undisclosed sex between men in national figures. PMID:26322977

  13. Spacecraft Parachute Recovery System Testing from a Failure Rate Perspective

    NASA Technical Reports Server (NTRS)

    Stewart, Christine E.

    2013-01-01

    Spacecraft parachute recovery systems, especially those with a parachute cluster, require testing to identify and reduce failures. This is especially important when the spacecraft in question is human-rated. Due to the recent effort to make spaceflight affordable, the importance of determining a minimum requirement for testing has increased. The number of tests required to achieve a mature design, with a relatively constant failure rate, can be estimated from a review of previous complex spacecraft recovery systems. Examination of the Apollo parachute testing and the Shuttle Solid Rocket Booster recovery chute system operation will clarify at which point in those programs the system reached maturity. This examination will also clarify the risks inherent in not performing a sufficient number of tests prior to operation with humans on-board. When looking at complex parachute systems used in spaceflight landing systems, a pattern begins to emerge regarding the need for a minimum amount of testing required to wring out the failure modes and reduce the failure rate of the parachute system to an acceptable level for human spaceflight. Not only a sufficient number of system level testing, but also the ability to update the design as failure modes are found is required to drive the failure rate of the system down to an acceptable level. In addition, sufficient data and images are necessary to identify incipient failure modes or to identify failure causes when a system failure occurs. In order to demonstrate the need for sufficient system level testing prior to an acceptable failure rate, the Apollo Earth Landing System (ELS) test program and the Shuttle Solid Rocket Booster Recovery System failure history will be examined, as well as some experiences in the Orion Capsule Parachute Assembly System will be noted.

  14. Effects of air ventilation during stationary exercise testing.

    PubMed

    Van Schuylenbergh, R; Vanden Eynde, B; Hespel, P

    2004-07-01

    The impact of air ventilation on performance and physiological responses during stationary exercise in the laboratory was studied. Fourteen well-trained cyclists performed three exercise tests on a cycle ergometer, each separated by a 1-week interval. The first test was a graded test to determine the power output corresponding with the 4-mmol l(-1) lactate level. Tests 2 and 3 were 30-min constant-load tests at a power output corresponding with this 4-mmol l(-1) lactate threshold. One constant-load test was performed in the absence (NAV), whilst the other was performed in the presence (AV) of air ventilation (3 m s(-1)). During the constant-load tests, heart rate, tympanic temperature, blood lactate concentration and oxygen uptake (VO2) were measured at 10-min intervals and at the end of the test. Differences between the two test conditions were evaluated using paired t-tests. During NAV, 12 subjects interrupted the test due to premature exhaustion (exercise duration <30 min), versus only seven in AV ( P<0.05). At the end of the test tympanic temperature was 35.9 (0.2) degrees C in AV and was higher in NAV [36.7 (0.2) degrees C, P<0.05]. Exercise heart rate increased at a faster rate during NAV [+2.2 (0.3) beats min(-1)] than during AV [+1.5 (0.2) beats min(-1), P<0.05]. Blood lactate concentration and VO2 were similar between conditions. Air ventilation is essential to prevent an upward shift in the lactate:heart rate as well as the power output:heart rate relationship during laboratory exercise testing and indoor exercise training.

  15. Miniature bulge test and energy release rate in HIPed aluminum/aluminum interfacial fracture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, C.; Lovato, M. L.; Clarke, K. D.

    We summarize the development of a technique of using miniature bulge test combined with three-dimensional digital image correlation (3D-DIC) for measuring energy release rate or fracture toughness of bimaterial interface of thin metal foils. Furthermore, the energy release rate associated with the HIPed aluminum/aluminum interfacial delamination is determined experimentally using the proposed technique. Detailed discussions of the schemes of preparing and conducting the bulge test, and computing various quantities required for the determination of the energy release rate are presented.

  16. Miniature bulge test and energy release rate in HIPed aluminum/aluminum interfacial fracture

    DOE PAGES

    Liu, C.; Lovato, M. L.; Clarke, K. D.; ...

    2017-10-13

    We summarize the development of a technique of using miniature bulge test combined with three-dimensional digital image correlation (3D-DIC) for measuring energy release rate or fracture toughness of bimaterial interface of thin metal foils. Furthermore, the energy release rate associated with the HIPed aluminum/aluminum interfacial delamination is determined experimentally using the proposed technique. Detailed discussions of the schemes of preparing and conducting the bulge test, and computing various quantities required for the determination of the energy release rate are presented.

  17. Biofidelity assessment of the 6-year-old ATDs in lateral impact.

    PubMed

    Yaek, J L; Li, Y; Lemanski, P J; Begeman, P C; Rouhana, S W; Cavanaugh, J M

    2016-07-03

    The objective of this study was to assess and compare the current lateral impact biofidelity of the shoulder, thorax, abdomen, and pelvis of the Q6, Q6s, and Hybrid III (HIII) 6-year-old anthropomorphic test devices (ATDs) through lateral impact testing. A series of lateral impact pendulum tests, vertical drop tests, and Wayne State University (WSU) sled tests was performed, based on the procedures detailed in ISO/TR 9790 (1999) and scaling to the 6-year-old using Irwin et al. ( 2002 ). The HIII used in this study was tested with the Ford-designed abdomen described in Rouhana ( 2006 ) and Elhagediab et al. ( 2006 ). The data collected from the 3 different ATDs were filtered using SAE J211 (SAE International 2003 ), aligned using the methodology described by Donnelly and Moorhouse ( 2012 ), and compared for each body region tested (shoulder, thorax, abdomen, and pelvis). The biofidelity performance in lateral impact for the 3 ATDs was assessed against the scaled biofidelity targets published in Irwin et al. ( 2002 ), the abdominal biofidelity target suggested in van Ratingen et al. ( 1997 ), and the biofidelity targets published in Rhule et al. ( 2013 ). Regional and overall biofidelity rankings for each of the 3 ATDs were performed using both the ISO 9790 biofidelity rating system (ISO/TR 9790 1999) and the NHTSA's external biofidelity ranking system (BRS; Rhule et al. 2013 ). All 3 6-year-old ATD's pelvises were rated as least biofidelic of the 4 body regions tested, based on both the ISO and BRS biofidelity rating systems, followed by the shoulder and abdomen, respectively. The thorax of all 3 ATDs was rated as the most biofidelic body region using the aforementioned biofidelity rating systems. The HIII 6-year-old ATD was rated last in overall biofidelity of the 3 tested ATDs, based on both rating systems. The Q6s ATD was rated as having the best overall biofidelity using both rating systems. All 3 ATDs are more biofidelic in the thorax and abdomen than the shoulder and pelvis, with the pelvis being the least biofidelic of all 4 tested body regions. None of the 3 tested 6-year-old ATDs had an overall ranking of 2.0 or less, based on the BRS ranking. Therefore, it is expected that none of the 3 ATDs would mechanically respond like a postmortem human subject (PMHS) in a lateral impact crash test based on this ranking system. With respect to the ISO biofidelity rating, the HIII dummy would be considered unsuitable and the Q-series dummies would be considered marginal for assessing side impact occupant protection.

  18. Soil-test N recommendations augmented with PEST optimized RZWQM simulations

    USDA-ARS?s Scientific Manuscript database

    Fertilizer application rates based on soil nitrate tests may help reduce N loss to the environment. The late spring nitrate test (LSNT) is one such test and improving our understanding of year-to-year N rate differences may increase its use. It is known that annual plant available soil N is associat...

  19. 77 FR 71669 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-03

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2013, through December 31, 2013, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...

  20. 76 FR 74843 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-01

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2012, through December 31, 2012, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...

  1. 75 FR 76069 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-07

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... minimum random drug and alcohol testing percentage rates for the period January 1, 2011, through December 31, 2011, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...

  2. 78 FR 77196 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2014, through December 31, 2014, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...

  3. Controlling Item Exposure Conditional on Ability in Computerized Adaptive Testing.

    ERIC Educational Resources Information Center

    Stocking, Martha L.; Lewis, Charles

    1998-01-01

    Ensuring item and pool security in a continuous testing environment is explored through a new method of controlling exposure rate of items conditional on ability level in computerized testing. Properties of this conditional control on exposure rate, when used in conjunction with a particular adaptive testing algorithm, are explored using simulated…

  4. 14 CFR 61.405 - What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating? 61.405 Section 61.405 Aeronautics and Space... flight instructor certificate with a sport pilot rating you must pass the following tests: (a) Knowledge...

  5. 14 CFR 61.405 - What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating? 61.405 Section 61.405 Aeronautics and Space... flight instructor certificate with a sport pilot rating you must pass the following tests: (a) Knowledge...

  6. Space Station Freedom seal leakage rate analysis and testing summary: Air leaks in ambient versus vacuum exit conditions

    NASA Technical Reports Server (NTRS)

    Rodriguez, P. I.; Markovitch, R.

    1992-01-01

    This report is intended to reveal the apparent relationship of air seal leakage rates between 2 atmospheres (atm) to 1 atm and 1 atm to vacuum conditions. Gas dynamics analysis is provided as well as data summarizing the MSFC test report, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study With Delta Pressure Leak Rate Comparison Test Report'.

  7. HIV counselling and testing practices for children seen in an urban emergency department of a tertiary referral hospital in Dar es Salaam, Tanzania: a retrospective cross-sectional study

    PubMed Central

    Sawe, Hendry R; Mfinanga, Juma A; Ringo, Faith H; Mwafongo, Victor; Reynolds, Teri A; Runyon, Michael S

    2016-01-01

    Objectives To describe the HIV counselling and testing practices for children presenting to an emergency department (ED) in a low-income country. Setting The ED of a large east African national referral hospital. Participants This retrospective review of all paediatric (<18 years old) ED visits in 2012 enrolled patients who had an HIV test ordered and excluded those without testing. Files were available for 5540/5774 (96%) eligible patients and 1632 (30%) were tested for HIV, median age 1.3 years (IQR 9 months to 4 years), 58% <18 months old and 61% male. Primary and secondary outcome measures The primary outcome measure was documentation of pretest and post-test counselling, or deferral of counselling, for children tested for HIV in the ED. Secondary measures included the overall rate of HIV testing, rate of counselling documented in the inpatient record when deferred in the ED, rate of counselling documented when testing was initiated by the inpatient service, rate of counselling documented by test result (positive vs negative) and the rate of referral to follow-up HIV care among patients testing positive. Results Of 418 patients tested in the ED, counselling, or deferral of counselling, was documented for 70 (17%). When deferred to the ward, subsequent counselling was documented for 15/42 (36%). Counselling was documented in 33% of patients testing positive versus 1.1% patients testing negative (OR 43 (95% CI 23 to 83). Of 199 patients who tested positive and survived to hospital discharge, 76 (38%) were referred for follow-up at the HIV clinic on discharge. Conclusions Physicians documented the provision, or deferral, of counselling for <20% of children tested for HIV in the ED. Counselling was much more likely to be documented when the test result was positive. Less than 40% of those testing positive were referred for follow-up care. PMID:26880672

  8. Live load testing and load rating of five reinforced concrete bridges.

    DOT National Transportation Integrated Search

    2014-10-01

    Five cast-in-place concrete T-beam bridges Eustis #5341, Whitefield #3831, Cambridge #3291, Eddington #5107, : and Albion #2832 were live load tested. Revised load ratings were computed either using test data or detailed : analysis when possi...

  9. Influence of the wording of evaluation items on outcome-based evaluation results for large-group teaching in anatomy, biochemistry and legal medicine.

    PubMed

    Anders, Sven; Pyka, Katharina; Mueller, Tjark; von Streinbuechel, Nicole; Raupach, Tobias

    2016-11-01

    Student learning outcome is an important dimension of teaching quality in undergraduate medical education. Measuring an increase in knowledge during teaching requires repetitive objective testing which is usually not feasible. As an alternative, student learning outcome can be calculated from student self-ratings. Comparative self-assessment (CSA) gain reflects the performance difference before and after teaching, adjusted for initial knowledge. It has been shown to be a valid proxy measure of actual learning outcome derived from objective tests. However, student self-ratings are prone to a number of confounding factors. In the context of outcome-based evaluation, the wording of self-rating items is crucial to the validity of evaluation results. This randomized trial assessed whether including qualifiers in these statements impacts on student ratings and CSA gain. First-year medical students self-rated their initial (then-test) and final (post-test) knowledge for lectures in anatomy, biochemistry and legal medicine, respectively, and 659 questionnaires were retrieved. Six-point scales were used for self-ratings with 1 being the most positive option. Qualifier use did not affect then-test ratings but was associated with slightly less favorable post-test ratings. Consecutively, mean CSA gain was smaller for items containing qualifiers than for items lacking qualifiers (50.6±15.0% vs. 56.3±14.6%, p=0.079). The effect was more pronounced (Cohen's d=0.82) for items related to anatomy. In order to increase fairness of outcome-based evaluation and increase the comparability of CSA gain data across subjects, medical educators should agree on a consistent approach (qualifiers for all items or no qualifiers at all) when drafting self-rating statements for outcome-based evaluation. Copyright © 2016 Elsevier GmbH. All rights reserved.

  10. Do gifts increase consent to home-based HIV testing? A difference-in-differences study in rural KwaZulu-Natal, South Africa

    PubMed Central

    McGovern, Mark E; Herbst, Kobus; Tanser, Frank; Mutevedzi, Tinofa; Canning, David; Gareta, Dickman; Pillay, Deenan; Bärnighausen, Till

    2016-01-01

    Abstract Background: Despite the importance of HIV testing for controlling the HIV epidemic, testing rates remain low. Efforts to scale up testing coverage and frequency in hard-to-reach and at-risk populations commonly focus on home-based HIV testing. This study evaluates the effect of a gift (a US$5 food voucher for families) on consent rates for home-based HIV testing. Methods: We use data on 18 478 individuals (6 418 men and 12 060 women) who were successfully contacted to participate in the 2009 and 2010 population-based HIV surveillance carried out by the Wellcome Trust's Africa Health Research Institute in rural KwaZulu-Natal, South Africa. Of 18 478 potential participants contacted in both years, 35% (6 518) consented to test in 2009, and 41% (7 533) consented to test in 2010. Our quasi-experimental difference-in-differences approach controls for unobserved confounding in estimating the causal effect of the intervention on HIV-testing consent rates. Results: Allocation of the gift to a family in 2010 increased the probability of family members consenting to test in the same year by 25 percentage points [95% confidence interval (CI) 21–30 percentage points; P < 0.001]. The intervention effect persisted, slightly attenuated, in the year following the intervention (2011). Conclusions: In HIV hyperendemic settings, a gift can be highly effective at increasing consent rates for home-based HIV testing. Given the importance of HIV testing for treatment uptake and individual health, as well as for HIV treatment-as-prevention strategies and for monitoring the population impact of the HIV response, gifts should be considered as a supportive intervention for HIV-testing initiatives where consent rates have been low. PMID:27940483

  11. LM193 Dual Differential Comparator Total Ionizing Dose Test Report

    NASA Technical Reports Server (NTRS)

    Topper, Alyson; Forney, James; Campola, Michael

    2017-01-01

    The purpose of this test was to characterize the flight lot of Texas Instruments' LM193 (flight part number is 5962-9452601Q2A) for total dose response. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) was determined.

  12. Standardized Testing Practices: Effect on Graduation and NCLEX® Pass Rates.

    PubMed

    Randolph, Pamela K

    The use standardized testing in pre-licensure nursing programs has been accompanied by conflicting reports of effective practices. The purpose of this project was to describe standardized testing practices in one states' nursing programs and discover if the use of a cut score or oversight of remediation had any effect on (a) first time NCLEX® pass rates, (b) on-time graduation (OTG) or (c) the combination of (a) and (b). Administrators of 38 nursing programs in one Southwest state were sent surveys; surveys were returned by 34 programs (89%). Survey responses were compared to each program's NCLEX pass rate and on-time graduation rate; t-tests were conducted for significant differences associated with a required minimum score (cut score) and oversight of remediation. There were no significant differences in NCLEX pass or on-time graduation rates related to establishment of a cut score. There was a significant difference when the NCLEX pass rate and on-time graduation rate were combined (Outcome Index "OI") with significantly higher program outcomes (P=.02.) for programs without cut-scores. There were no differences associated with faculty oversight of remediation. The results of this study do not support establishment of a cut-score when implementing a standardized testing. Copyright © 2016. Published by Elsevier Inc.

  13. Propagation mode of Portevin-Le Chatelier plastic instabilities in an aluminium-magnesium alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeghloul, A.; Mliha-Touati, M.; Bakir, S.

    1996-11-01

    The Portevin-Le Chatelier (PLC) effect is characterized by the appearance of serrations in load (hard tensile machine for constant strain rate tests) or by steps (soft tensile machine for constant stress rate tests) or by steps (soft tensile machine for constant stress rate tests) on the stress-strain curves. It is now widely accepted that the PLC propagative instability stems from the dynamic interaction between diffusing solute atoms and mobile dislocations in the temperature and strain rate ranges where dynamic strain ageing (DSA) takes place. This competition results in a negative strain-rate sensitivity. However, in some alloys, like concentrated solid solutions,more » shearing of precipitates accompanied by their dissolution and subsequent reprecipitation during tensile test may also lead to a negative strain rate sensitivity. In view of the renewed theoretical interest in propagative instabilities, it is important that the experimental features of band propagation be well characterized. In this work the authors present experimental results that are obtained from the investigation of the PLC bands associated with discontinuous yielding. These results show that the band strain, the band velocity and the propagation mode of the bands depend on the stress rate when the test is carried out on a soft tensile machine.« less

  14. CO2 Washout Testing of the REI and EM-ACES Space Suits

    NASA Technical Reports Server (NTRS)

    Mitchell, Kate; Norcross, Jason

    2011-01-01

    Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. The objective of this test was to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) across a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice to allow for comparison between tests. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of approximately 500 to 3000 BTU/hr. Supply airflow was varied at 6, 5 and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was primarily affected by the metabolic rate of the subject, with increased metabolic rate resulting in increased inspired ppCO2. Suit flow rate also affected inspired ppCO2, with decreased flow causing small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates greater than or equal to 2000 BTU/hr. Results were consistent between suits, with the EM-ACES demonstrating slightly better CO2 washout than the REI suit, but not statistically significant. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future ground testing in the REI and EM-ACES.

  15. The Effect of the Laboratory Specimen on Fatigue Crack Growth Rate

    NASA Technical Reports Server (NTRS)

    Forth, S. C.; Johnston, W. M.; Seshadri, B. R.

    2006-01-01

    Over the past thirty years, laboratory experiments have been devised to develop fatigue crack growth rate data that is representative of the material response. The crack growth rate data generated in the laboratory is then used to predict the safe operating envelope of a structure. The ability to interrelate laboratory data and structural response is called similitude. In essence, a nondimensional term, called the stress intensity factor, was developed that includes the applied stresses, crack size and geometric configuration. The stress intensity factor is then directly related to the rate at which cracks propagate in a material, resulting in the material property of fatigue crack growth response. Standardized specimen configurations and experimental procedures have been developed for laboratory testing to generate crack growth rate data that supports similitude of the stress intensity factor solution. In this paper, the authors present laboratory fatigue crack growth rate test data and finite element analyses that show similitude between standard specimen configurations tested using the constant stress ratio test method is unobtainable.

  16. Electrical, thermal and abusive tests on lithium thionyl chloride cells

    NASA Technical Reports Server (NTRS)

    Frank, H. A.

    1980-01-01

    Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.

  17. Electrical, thermal and abusive tests on lithium thionyl chloride cells

    NASA Astrophysics Data System (ADS)

    Frank, H. A.

    1980-04-01

    Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.

  18. 75 FR 9018 - Pipeline Safety: Random Drug Testing Rate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2010-0034] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...

  19. 77 FR 2606 - Pipeline Safety: Random Drug Testing Rate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-18

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2012-0004] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...

  20. Association Between Direct-to-Consumer Advertising and Testosterone Testing and Initiation in the United States, 2009–2013

    PubMed Central

    Layton, J. Bradley; Kim, Yoonsang; Alexander, G. Caleb; Emery, Sherry L.

    2017-01-01

    IMPORTANCE Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. OBJECTIVE To investigate associations between televised DTCA and testosterone testing and initiation in the United States. DESIGN, SETTING, AND POPULATION Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009–2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. EXPOSURES Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. MAIN OUTCOMES AND MEASURES (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. RESULTS Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004–1.008), initiation (RR, 1.007; 95% CI, 1.004–1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002–1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09–0.19), 0.05 new initiations (95% CI, 0.03–0.08), and 0.02 initiations without a recent test (95% CI, 0.01–0.03) per 10 000 men for each monthly ad exposure over the entire period. CONCLUSIONS AND RELEVANCE Among US men residing in the 75 designated market areas, regional exposure to televised direct-to-consumer advertising was associated with greater testosterone testing, new initiation, and initiation without recent testing. PMID:28324090

  1. Instrument Pilot: Airplane. Flight Test Guide, Part 61 Revised 1973, AC 61-56.

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.

    This flight test guide is designed to assist the applicant and his instructor in preparing for the flight test for Instrument Pilot Airplane Rating under Part 61 (revised) of Federal Aviation Regulations. It contains information concerning pilot operations, procedures, and maneuvers relevant to the flight test required for the Instrument Rating.…

  2. The Frequency of Optical Coherence Tomography Testing in Glaucoma at a Single Academic Medical Center.

    PubMed

    Griffith, Joseph F; Goldberg, Jeffrey L

    2016-03-01

    To determine the frequency of optical coherence tomography (OCT) examinations compared with clinical examinations and visual field (VF) tests in patients with 5 types of glaucoma. A retrospective, longitudinal cohort study was conducted of 5154 patients treated between 2003 and 2010 at a single academic medical center. Patients were classified using billing records as having primary open-angle glaucoma, low-tension open-angle glaucoma (NTG), pigmentary open-angle glaucoma, chronic angle-closure glaucoma, or pseudoexfoliation glaucoma. Analysis of variance, χ test, and exact χ test were performed to identify associations between glaucoma type and test frequency. Pigmentary open-angle glaucoma and NTG patients had a higher rate of undergoing at least 2 VFs (94.4%, 94.9%), and chronic angle-closure glaucoma patients had a lower rate of undergoing at least 2 OCTs (25.3%) than all other glaucoma types. NTG patients also had the highest rate of undergoing at least 2 OCTs and at least 2 VFs (36.6%). Overall, the rate of clinical examinations (2.68 examinations/y) exceeded the rates of OCTs (1.39 examinations/y), which exceeded the rate of VF tests (1.24 tests/y). There were no differences in OCT frequency between glaucoma types (0.91 to 1.63 OCTs/y). Within each glaucoma diagnosis, patients had clinical examinations more frequently than OCTs and clinical examinations more frequently than VFs. Primary open-angle glaucoma and pseudoexfoliation glaucoma patients also had OCTs more frequently than VFs. More patients had at least 2 VF tests than at least 2 OCTs (4481 vs. 1679). The relative use of clinical examinations, VF testing, and OCT imaging varies among glaucoma diagnoses.

  3. Technology diffusion and diagnostic testing for prostate cancer.

    PubMed

    Schroeck, Florian R; Kaufman, Samuel R; Jacobs, Bruce L; Skolarus, Ted A; Miller, David C; Weizer, Alon Z; Montgomery, Jeffrey S; Wei, John T; Shahinian, Vahakn B; Hollenbeck, Brent K

    2013-11-01

    While the dissemination of robotic prostatectomy and intensity modulated radiotherapy may fuel the increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with the receipt of prostate specific antigen testing and prostate biopsy. In this retrospective cohort study we included 117,857 men 66 years old or older from the 5% sample of Medicare beneficiaries living in Surveillance, Epidemiology and End Results (SEER) areas from 2003 to 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or intensity modulated radiotherapy per population in a health care market, ie hospital referral region. We assessed the association of technology penetration with the prostate specific antigen testing rate and prostate biopsy using generalized estimating equations. High technology penetration was associated with an increased rate of prostate specific antigen testing (442 vs 425/1,000 person-years, p<0.01) and a similar rate of prostate biopsy (10.1 vs 9.9/1,000 person-years, p=0.69). The impact of technology penetration on prostate specific antigen testing and prostate biopsy was much less than the effect of age, race and comorbidity, eg the prostate specific antigen testing rate per 1,000 person-years was 485 vs 373 for men with only 1 vs 3+ comorbid conditions (p<0.01). Increased technology penetration is associated with a slightly higher rate of prostate specific antigen testing and no change in the prostate biopsy rate. Collectively, our findings temper concerns that adopting new technology accelerates diagnostic testing for prostate cancer. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. The value of Bayes' theorem for interpreting abnormal test scores in cognitively healthy and clinical samples.

    PubMed

    Gavett, Brandon E

    2015-03-01

    The base rates of abnormal test scores in cognitively normal samples have been a focus of recent research. The goal of the current study is to illustrate how Bayes' theorem uses these base rates--along with the same base rates in cognitively impaired samples and prevalence rates of cognitive impairment--to yield probability values that are more useful for making judgments about the absence or presence of cognitive impairment. Correlation matrices, means, and standard deviations were obtained from the Wechsler Memory Scale--4th Edition (WMS-IV) Technical and Interpretive Manual and used in Monte Carlo simulations to estimate the base rates of abnormal test scores in the standardization and special groups (mixed clinical) samples. Bayes' theorem was applied to these estimates to identify probabilities of normal cognition based on the number of abnormal test scores observed. Abnormal scores were common in the standardization sample (65.4% scoring below a scaled score of 7 on at least one subtest) and more common in the mixed clinical sample (85.6% scoring below a scaled score of 7 on at least one subtest). Probabilities varied according to the number of abnormal test scores, base rates of normal cognition, and cutoff scores. The results suggest that interpretation of base rates obtained from cognitively healthy samples must also account for data from cognitively impaired samples. Bayes' theorem can help neuropsychologists answer questions about the probability that an individual examinee is cognitively healthy based on the number of abnormal test scores observed.

  5. Carbon Dioxide Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

    NASA Technical Reports Server (NTRS)

    Korona, F. Adam; Norcross, Jason; Conger, Bruce; Navarro, Moses

    2014-01-01

    Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy, and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject, and physiological differences between subjects. Computational Fluid Dynamics (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit, and the Enhanced Mobility Advanced Crew Escape Suit. Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

  6. How much does a reminder letter increase cervical screening among under-screened women in NSW?

    PubMed

    Morrell, Stephen; Taylor, Richard; Zeckendorf, Sue; Niciak, Amanda; Wain, Gerard; Ross, Jayne

    2005-02-01

    To evaluate a direct mail-out campaign to increase Pap screening rates in women who have not had a test in 48 months. Ninety thousand under-screened women were randomised to be mailed a 48-month reminder letter to have a Pap test (n=60,000), or not to be mailed a letter (n=30,000). Differences in Pap test rates were assessed by Kaplan-Meier survival analysis, by chi2 tests of significance between Pap test rates in letter versus no-letter groups, and by proportional hazards regression modelling of predictors of a Pap test with letter versus no-letter as the main study variable. T-tests were conducted on mean time to Pap test to assess whether time to Pap test was significantly different between the intervention and control groups. After 90 days following each mail-out, Pap test rates in the letter group were significantly higher than in the non-letter group, by approximately two percentage points. After controlling for potential confounders, the hazard ratio of a Pap test within 90 days of a mail-out in the letter group was 1.5 compared with 1.0 in the no-letter group. Hazard ratios of having a Pap test within 90 days decreased significantly with time since last Pap test (p<0.0001); were significantly higher than 1.0 for most non-metropolitan areas of NSW compared with metropolitan areas; and increased significantly with age (p<0.0001). Pap test hazard ratios were not associated with socio-economic status of area of residence, but the hazard ratio was significantly higher than 1.0 if the reminder letter was sent after the Christmas/New Year break. No significant differences in mean time to Pap test were found between the letter and no-letter groups. Being sent a reminder letter is associated with higher Pap testing rates in under-screened women.

  7. [The maximum heart rate in the exercise test: the 220-age formula or Sheffield's table?].

    PubMed

    Mesquita, A; Trabulo, M; Mendes, M; Viana, J F; Seabra-Gomes, R

    1996-02-01

    To determine in the maximum cardiac rate in exercise test of apparently healthy individuals may be more properly estimated through 220-age formula (Astrand) or the Sheffield table. Retrospective analysis of clinical history and exercises test of apparently healthy individuals submitted to cardiac check-up. Sequential sampling of 170 healthy individuals submitted to cardiac check-up between April 1988 and September 1992. Comparison of maximum cardiac rate of individuals studied by the protocols of Bruce and modified Bruce, in interrupted exercise test by fatigue, and with the estimated values by the formulae: 220-age versus Sheffield table. The maximum cardiac heart rate is similar with both protocols. This parameter in normal individuals is better predicted by the 220-age formula. The theoretic maximum cardiac heart rate determined by 220-age formula should be recommended for a healthy, and for this reason the Sheffield table has been excluded from our clinical practice.

  8. Final Report - Melt Rate Enhancement for High Aluminum HLW Glass Formulation, VSL-08R1360-1, Rev. 0, dated 12/19/08

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, Albert A.; Pegg, I. L.; Chaudhuri, M.

    2013-11-13

    The principal objective of the work reported here was to develop and identify HLW glass compositions that maximize waste processing rates for the aluminum limted waste composition specified by ORP while maintaining high waste loadings and acceptable glass properties. This was accomplished through a combination of crucible-scale tests, confirmation tests on the DM100 melter system, and demonstration at pilot scale (DM1200). The DM100-BL unit was selected for these tests since it was used previously with the HLW waste streams evaluated in this study, was used for tests on HLW glass compositions to support subsequent tests on the HLW Pilot Melter,more » conduct tests to determine the effect of various glass properties (viscosity and conductivity) and oxide concentrations on glass production rates with HLW feed streams, and to assess the volatility of cesium and technetium during the vitrification of an HLW AZ-102 composition. The same melter was selected for the present tests in order to maintain comparisons between the previously collected data. These tests provide information on melter processing characteristics and off-gas data, including formation of secondary phases and partitioning. Once DM100 tests were completed, one of the compositions was selected for further testing on the DM1200; the DM1200 system has been used for processing a variety of simulated Hanford waste streams. Tests on the larger melter provide processing data at one third of the scale of the actual WTP HLW melter and, therefore, provide a more accurate and reliable assessment of production rates and potential processing issues. The work focused on maximizing waste processing rates for high aluminum HLW compositions. In view of the diversity of forms of aluminum in the Hanford tanks, tests were also conducted on the DM100 to determine the effect of changes in the form of aluminum on feed properties and production rate. In addition, the work evaluated the effect on production rate of modest increases in melter operating temperature. Glass composition development was based on one of the HLW waste compositions specified by ORP that has a high concentration of aluminum. Small-scale tests were used to provide an initial screening of various glass formulations with respect to melt rates; more definitive screening was provided by the subsequent DM100 tests. Glass properties evaluated included: viscosity, electrical conductivity, crystallinity, gross glass phase separation and the 7- day Product Consistency Test (ASTM-1285). Glass property limits were based upon the reference properties for the WTP HLW melter. However, the WTP crystallinity limit (< 1 vol% at 950oC) was relaxed slightly as a waste loading constraint for the crucible melts.« less

  9. Biodegradation of the surfactant linear alkylbenzenesulfonate in sewage- contaminated groundwater: A comparison of column experiments and field tracer tests

    USGS Publications Warehouse

    Krueger, C.J.; Radakovich, K.M.; Sawyer, T.E.; Barber, L.B.; Smith, R.L.; Field, J.A.

    1998-01-01

    Transport and biodegradation of linear alkylbenzenesulfonate (LAS) in sewage-contaminated groundwater were investigated for a range of dissolved oxygen concentrations. Both laboratory column and an 80-day continuous injection tracer test field experiments were conducted. The rates of LAS biodegradation increased with increasing dissolved oxygen concentrations and indicated the preferential biodegradation of the longer alkyl chain LAS homologues (i.e., C12 and C13) and external isomers (i.e., 2-and 3- phenyl). However, for similar dissolved oxygen concentrations, mass removal rates for LAS generally were 2-3 times greater in laboratory column experiments than in the field tracer test. Under low oxygen conditions (<1 mg/L) only a fraction of the LAS mixture biodegraded in both laboratory and field experiments. Biodegradation rate constants for the continuous injection field test (0.002-0.08 day-1) were comparable to those estimated for a 3-h injection (pulsed) tracer test conducted under similar biogeochemical conditions, indicating that increasing the exposure time of aquifer sediments to LAS did not increase biodegradation rates.Transport and biodegradation of linear alkylbenzenesulfonate (LAS) in sewage-contaminated groundwater were investigated for a range of dissolved oxygen concentrations. Both laboratory column and an 80-day continuous injection tracer test field experiments were conducted. The rates of LAS biodegradation increased with increasing dissolved oxygen concentrations and indicated the preferential biodegradation of the longer alkyl chain LAS homologues (i.e., C12 and C13) and external isomers (i.e., 2- and 3-phenyl). However, for similar dissolved oxygen concentrations, mass removal rates for LAS generally were 2-3 times greater in laboratory column experiments than in the field tracer test. Under low oxygen conditions (<1 mg/L) only a fraction of the LAS mixture biodegraded in both laboratory and field experiments. Biodegradation rate constants for the continuous injection field test (0.002-0.08 day-1) were comparable to those estimated for a 3-h injection (pulsed) tracer test conducted under similar biogeochemical conditions, indicating that increasing the exposure time of aquifer sediments to LAS did not increase biodegradation rates.

  10. Variation in healthcare services for specialist genetic testing and implications for planning genetic services: the example of inherited retinal dystrophy in the English NHS.

    PubMed

    Harrison, Mark; Birch, Stephen; Eden, Martin; Ramsden, Simon; Farragher, Tracey; Payne, Katherine; Hall, Georgina; Black, Graeme Cm

    2015-04-01

    This study aims to identify and quantify the extent of current variation in service provision of a genetic testing service for dominant and X-linked retinal dystrophies in the English National Health Service (NHS). National audit data (all test requests and results (n = 1839) issued between 2003 and 2011) and survey of English regional genetic testing services were used. Age- and gender-adjusted standardised testing rates were calculated using indirect standardisation, and survey responses were transcribed verbatim and data collated and summarised. The cumulative incidence rate of testing in England was 4.5 per 100,000 population for males and 2.6 per 100,000 population for females. The standardised testing rate (STR) varied widely between regions of England, being particularly low in the North-east (STR 0.485), with half as many tests as expected based on the size and demographic distribution of the population and high in the South-east (STR 1.355), with 36 % more tests than expected. Substantial and significantly different rates of testing were found between regional populations. Specific policy mechanisms to promote, monitor and evaluate the regional distribution of access to genetic and genomic testing are required. However, commissioners will require information on the scope and role of genetic services and the population at risk of the conditions for which patients are tested.

  11. Implementation and Operational Research: Effectiveness and Patient Acceptability of a Sexually Transmitted Infection Self-Testing Program in an HIV Care Setting.

    PubMed

    Barbee, Lindley A; Tat, Susana; Dhanireddy, Shireesha; Marrazzo, Jeanne M

    2016-06-01

    Rates of screening for bacterial sexually transmitted infections (STI) among men who have sex with men in HIV care settings remain low despite high prevalence of these infections. STI self-testing may help increase screening rates in clinical settings. We implemented an STI self-testing program at a large, urban HIV care clinic and evaluated its effectiveness and acceptability. We compared measures obtained during the first year of the STI self-testing program (Intervention Year, April 1, 2013-March 31, 2014) to Baseline Year (January 1, 2012-December 31, 2012) to determine: (1) overall clinic change in STI testing coverage and diagnostic yield and; (2) program-specific outcomes including appropriate anatomic site screening and patient-reported acceptability. Overall, testing for gonorrhea and chlamydia increased significantly between Baseline and Intervention Year, and 50% more gonococcal and 47% more chlamydial infections were detected. Syphilis testing coverage remained unchanged. Nearly 95% of 350 men who participated in the STI self-testing program completed site-specific testing appropriately based on self-reported exposures, and 92% rated their self-testing experience as "good" or "very good." STI self-testing in HIV care settings significantly increases testing coverage and detection of gonorrhea and chlamydia, and the program is acceptable to patients. Additional interventions to increase syphilis screening rates are needed.

  12. Aerosol collection of the (Bladewerx Corporation) breathing zone monitor and portable workplace monitor.

    PubMed

    Moore, Murray E; Kennedy, Trevor J; Dimmerling, Paul J

    2007-11-01

    The Radiation Protection Group at the Los Alamos National Laboratory has a wind tunnel capable of measuring the aerosol collection efficiencies of air sampling devices. In the fall of 2005, the group received an internal Los Alamos request to perform aerosol collection efficiency tests on two air samplers manufactured by the Bladewerx Corporation (Rio Rancho, NM). This paper presents the results from tests performed in the wind tunnel facility at a test velocity of 0.5 m s. The SabreAlert (Portable Workplace Monitor) and the SabreBZM (Breathing Zone Monitor) are both designed to detect and measure the presence of alpha emitting isotopes in atmospheres. The SabreAlert was operated at two test air flow rates of 6 and 45 liters per minute (LPM), and the SabreBZM was operated at two test air flow rates of 3 and 19 LPM. The aerosol collection efficiencies of both samplers were evaluated with oleic acid (monodisperse) liquid droplet aerosols tagged with sodium fluorescein tracer. These test aerosols varied in size from about 2.3 to 17.2 microns (aerodynamic equivalent diameter). The SabreAlert was roughly 100% efficient in aerosol collection at a flow rate of 6 LPM, and had an aerodynamic cutpoint diameter of 11.3 microns at the 45 LPM flow rate. The SabreBZM had an aerodynamic cutpoint diameter of 6.7 microns at the 3 LPM flow rate, but the SabreBZM aerosol collection efficiency never exceeded 13.6% at the 19 LPM test flow rate condition.

  13. Intraoperatively Testing the Anastomotic Integrity of Esophagojejunostomy Using Methylene Blue.

    PubMed

    Celik, S; Almalı, N; Aras, A; Yılmaz, Ö; Kızıltan, R

    2017-03-01

    Intraoperative testing of gastrointestinal anastomosis effectively ensures anastomotic integrity. This study investigated whether the routine use of methylene blue intraoperatively identified leaks to reduce the postoperative proportion of clinical leaks. This study retrospectively analyzed consecutive total gastrectomies performed from January 2007 to December 2014 in a university hospital setting by a general surgical group that exclusively used the methylene blue test. All surgeries were performed for gastric or junctional cancers (n = 198). All reconstructions (Roux-en Y esophagojejunostomy) were performed using a stapler. The methylene blue test was used in 108 cases (group 1) via a nasojejunal tube. No test was performed for the other 90 cases (group 2). Intraoperative leakage rate, postoperative clinical leakage rate, length of hospitalization, and mortality rate were the outcome measures. The intraoperative leakage rate was 7.4% in group 1. The postoperative clinical leakage rate was 8.6%. The postoperative clinical leakage rate was 3.7% in group 1 and 14.4% in group 2 (p = 0.007). There were no postoperative clinical leaks when an intraoperative leak led to concomitant intraoperative repair. The median length of hospital stay was 6 days in group 1 and 8 days in group 2 (p < 0.001). One death occurred in each group. No test-related complications were observed. The methylene blue test for esophagojejunostomy is a safe and reliable method for the assessment of anastomosis integrity, especially in cases with difficult esophagojejunostomic construction.

  14. Assessing personality in San Joaquin kit fox in situ: efficacy of field-based experimental methods and implications for conservation management.

    PubMed

    Bremner-Harrison, Samantha; Cypher, Brian L; Van Horn Job, Christine; Harrison, Stephen W R

    2018-01-01

    Utilisation of animal personality has potential benefit for conservation management. Due to logistics of robust behavioural evaluation in situ, the majority of studies on wild animals involve taking animals into captivity for testing, potentially compromising results. Three in situ tests for evaluation of boldness in San Joaquin kit fox ( Vulpes macrotis mutica ) were developed (ENOT: extended novel object test; RNOT: rapid novel object test; TH: trap/handling test). Each test successfully identified variation in boldness within its target age class(es). The TH test was suitable for use across all age classes. Tests were assessed for in situ suitability and for quantity/quality of data yielded. ENOT was rated as requiring high levels of time, cost and labour with greater likelihood of failure. However, it was rated highly for data quantity/quality. The TH test was rated as requiring little time, labour and cost, but yielding lower quality data. RNOT was rated in the middle. Each test had merit and could be adapted to suit project or species constraints. We recommend field-based evaluation of personality, reducing removal of animals from the wild and facilitating routine incorporation of personality assessment into conservation projects.

  15. Slow Crack Growth Analysis of Advanced Structural Ceramics Under Combined Loading Conditions: Damage Assessment in Life Prediction Testing

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    2000-01-01

    Slow crack growth analysis was performed with three different loading histories including constant stress-rate/constant stress-rate testing (Case 1 loading), constant stress/constant stress-rate testing (Case 2 loading), and cyclic stress/constant stress-rate testing (Case 2 loading). Strength degradation due to slow crack growth and/or damage accumulation was determined numerically as a function of percentage of interruption time between the two loading sequences for a given loading history. The numerical solutions were examined with the experimental data determined at elevated temperatures using four different advanced ceramic materials, two silicon nitrides, one silicon carbide and one alumina for the Case 1 loading history, and alumina for the Case 3 loading history. The numerical solutions were in reasonable agreement with the experimental data, indicating that notwithstanding some degree of creep deformation presented for some test materials slow crack growth was a governing mechanism associated with failure for all the test materials.

  16. Slow Crack Growth Analysis of Advanced Structural Ceramics Under Combined Loading Conditions: Damage Assessment in Life Prediction Testing

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    2000-01-01

    Slow crack growth analysis was performed with three different loading histories including constant stress-rate/constant stress-rate testing (Case I loading), constant stress/constant stress-rate testing (Case II loading), and cyclic stress/constant stress-rate testing (Case III loading). Strength degradation due to slow crack growth arid/or damage accumulation was determined numerically as a Function of percentage of interruption time between the two loading sequences for a given loading history. The numerical solutions were examined with the experimental data determined at elevated temperatures using four different advanced ceramic materials, two silicon nitrides, one silicon carbide and one alumina for the Case I loading history, and alumina for the Case II loading history. The numerical solutions were in reasonable agreement with the experimental data, indicating that notwithstanding some degree of creep deformation presented for some test materials slow crack growth was a governing mechanism associated with failure for all the test material&

  17. Accelerated Testing Methodology in Constant Stress-Rate Testing for Advanced Structural Ceramics: A Preloading Technique

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.; Huebert, Dean; Bartlett, Allen; Choi, Han-Ho

    2001-01-01

    Preloading technique was used as a means of an accelerated testing methodology in constant stress-rate ('dynamic fatigue') testing for two different brittle materials. The theory developed previously for fatigue strength as a function of preload was further verified through extensive constant stress-rate testing for glass-ceramic and CRT glass in room temperature distilled water. The preloading technique was also used in this study to identify the prevailing failure mechanisms at elevated temperatures, particularly at lower test rate in which a series of mechanisms would be associated simultaneously with material failure, resulting in significant strength increase or decrease. Two different advanced ceramics including SiC whisker-reinforced composite silicon nitride and 96 wt% alumina were used at elevated temperatures. It was found that the preloading technique can be used as an additional tool to pinpoint the dominant failure mechanism that is associated with such a phenomenon of considerable strength increase or decrease.

  18. Accelerated Testing Methodology in Constant Stress-Rate Testing for Advanced Structural Ceramics: A Preloading Technique

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.; Huebert, Dean; Bartlett, Allen; Choi, Han-Ho

    2001-01-01

    Preloading technique was used as a means of an accelerated testing methodology in constant stress-rate (dynamic fatigue) testing for two different brittle materials. The theory developed previously for fatigue strength as a function of preload was further verified through extensive constant stress-rate testing for glass-ceramic and CRT glass in room temperature distilled water. The preloading technique was also used in this study to identify the prevailing failure mechanisms at elevated temperatures, particularly at lower test rates in which a series of mechanisms would be associated simultaneously with material failure, resulting in significant strength increase or decrease. Two different advanced ceramics including SiC whisker-reinforced composite silicon nitride and 96 wt% alumina were used at elevated temperatures. It was found that the preloading technique can be used as an additional tool to pinpoint the dominant failure mechanism that is associated with such a phenomenon of considerable strength increase or decrease.

  19. Streptococcal Pharyngitis and Appendicitis in Children.

    PubMed

    Nielsen, Jason W; Abel, Stuart A; Kenney, Brian

    2018-01-01

    Several pathologies, including pharyngitis, are associated with abdominal pain that can mimic appendicitis. We sought to further understand the link between appendicitis-like symptoms and streptococcal (strep) pharyngitis. All patients undergoing ultrasound imaging for appendicitis in our emergency department during 2013 were reviewed (n = 1572). A total of 207 patients were identified who underwent both ultrasound for appendicitis and testing for strep pharyngitis. Demographic and outcomes data between rule out appendicitis patients who underwent strep testing and those who did not were compared. Strep testing was more common in younger patients (mean age = 8.26 vs 10.26 years P < .001) and evenly matched by gender (104 male, 103 female). Of the 207 patients tested for strep pharyngitis, 8 (3.9%) patients had appendicitis and 35 (16.9%) patients tested positive for strep pharyngitis. No cases of concurrent strep pharyngitis and appendicitis were identified. The negative appendectomy rate in the strep pharyngitis tested group was 38.5% (5/13), compared with 7.7% (23/296) ( P = .003) in the nontested group. The appendicitis rate among the strep tested group was 3.8% (8/207) compared with 20% (273/1365) in the nontested group ( P < .001). Patients undergoing testing for strep pharyngitis were younger, had lower rates of appendicitis, and had a higher rate of negative appendectomy. A diagnosis of concurrent appendicitis and strep pharyngitis is rare. In cases of patients with sufficient symptoms to warrant testing for strep pharyngitis a diagnosis of appendicitis is less likely and surgical intervention leads to higher negative appendectomy rates.

  20. A General Class of Test Statistics for Van Valen’s Red Queen Hypothesis

    PubMed Central

    Wiltshire, Jelani; Huffer, Fred W.; Parker, William C.

    2014-01-01

    Van Valen’s Red Queen hypothesis states that within a homogeneous taxonomic group the age is statistically independent of the rate of extinction. The case of the Red Queen hypothesis being addressed here is when the homogeneous taxonomic group is a group of similar species. Since Van Valen’s work, various statistical approaches have been used to address the relationship between taxon age and the rate of extinction. We propose a general class of test statistics that can be used to test for the effect of age on the rate of extinction. These test statistics allow for a varying background rate of extinction and attempt to remove the effects of other covariates when assessing the effect of age on extinction. No model is assumed for the covariate effects. Instead we control for covariate effects by pairing or grouping together similar species. Simulations are used to compare the power of the statistics. We apply the test statistics to data on Foram extinctions and find that age has a positive effect on the rate of extinction. A derivation of the null distribution of one of the test statistics is provided in the supplementary material. PMID:24910489

  1. A General Class of Test Statistics for Van Valen's Red Queen Hypothesis.

    PubMed

    Wiltshire, Jelani; Huffer, Fred W; Parker, William C

    2014-09-01

    Van Valen's Red Queen hypothesis states that within a homogeneous taxonomic group the age is statistically independent of the rate of extinction. The case of the Red Queen hypothesis being addressed here is when the homogeneous taxonomic group is a group of similar species. Since Van Valen's work, various statistical approaches have been used to address the relationship between taxon age and the rate of extinction. We propose a general class of test statistics that can be used to test for the effect of age on the rate of extinction. These test statistics allow for a varying background rate of extinction and attempt to remove the effects of other covariates when assessing the effect of age on extinction. No model is assumed for the covariate effects. Instead we control for covariate effects by pairing or grouping together similar species. Simulations are used to compare the power of the statistics. We apply the test statistics to data on Foram extinctions and find that age has a positive effect on the rate of extinction. A derivation of the null distribution of one of the test statistics is provided in the supplementary material.

  2. Utilization of stat test priority in the clinical laboratory: a College of American Pathologists q-probes study of 52 institutions.

    PubMed

    Volmar, Keith E; Wilkinson, David S; Wagar, Elizabeth A; Lehman, Christopher M

    2013-02-01

    Utilization of stat testing priority is a balance between safe, efficient patient management and resource expenditure. To determine the rate of stat testing, compare rates among institutions, and determine the distribution of turnaround time expectations for different turnaround time priorities. During a 7-day period, participants prospectively determined the total number of chemistry, hematology, and coagulation billable tests from inpatients and emergency department patients. Among these, the total numbers of billable tests performed stat were identified. Laboratories also reported the levels of test priority they offered and turnaround expectations for each level of test priority. Fifty institutions submitted data for the study, with 2 additional participants submitting partial results. Participants identified 639 589 chemistry, hematology, and coagulation billable tests, with 229 896 (35.9%) performed stat. The stat rate varied from 21.3% at the 10th percentile to 55.4% at the 90th percentile, with a median of 37.0% of participants' tests performed stat. Laboratories include a mean of 206 tests in chemistry, hematology, and coagulation test menus, with 67% of these tests offered stat. The fraction of the test menu offered stat varied from 29.0% at the 10th percentile to 97.8% at the 90th percentile, with a median of 73.3% of tests on the menu offered stat. The most common number of testing priorities offered by participating laboratories was 3 (44.2%). Among the 52 participating laboratories, the median stat testing rate was 37.0% and a median 73.3% of the test menu was offered stat.

  3. Factors Affecting Specific-Capacity Tests and their Application--A Study of Six Low-Yielding Wells in Fractured-Bedrock Aquifers in Pennsylvania

    USGS Publications Warehouse

    Risser, Dennis W.

    2010-01-01

    This report by the U.S. Geological Survey, prepared in cooperation with the Pennsylvania Department of Environmental Protection, Bureau of Mining and Reclamation, evaluates factors affecting the application of specific-capacity tests in six low-yielding water wells in areas of coal mining or quarrying in Pennsylvania. Factors such as pumping rate, duration of pumping, aquifer properties, wellbore storage, and turbulent flow were assessed by theoretical analysis and by completing multiple well tests, selected to be representative of low-yielding household-supply wells in areas of active coal mining or quarrying. All six wells were completed in fractured-bedrock aquifers--five in coal-bearing shale, siltstone, sandstone, limestone, and coal of Pennsylvanian and Permian age and one in limestone of Cambrian age. The wells were pumped 24 times during 2007-09 at rates from 0.57 to 14 gallons per minute during tests lasting from 22 to 240 minutes. Geophysical logging and video surveys also were completed to determine the depth, casing length, and location of water-yielding zones in each of the test wells, and seasonal water-level changes were measured during 2007-09 by continuous monitoring at each well. The tests indicated that specific-capacity values were reproducible within about ? 20 percent if the tests were completed at the same pumping rate and duration. A change in pumping duration, pumping rate, or saturated aquifer thickness can have a substantial effect on the comparability of repeated tests. The largest effect was caused by a change in aquifer thickness in well YO 1222 causing specific capacity from repeated tests to vary by a factor of about 50. An increase in the duration of pumping from 60 to 180 minutes caused as much as a 62 percent decrease in specific capacity. The effect of differing pumping rates on specific capacity depends on whether or not the larger rate causes the water level in the well to fall below a major water-yielding zone; when this decline happened at well CA 462, specific capacity was reduced by about 63 percent. Estimates of the maximum yield for low-yielding wells that are computed by multiplying the available drawdown by the specific-capacity value may contain large errors if the wells were pumped at low rates that do not cause much water-level drawdown. The estimates of yield are likely to be too large because the effects of lowering the water level in the well below water-yielding zones have not been incorporated. Better yield estimates can be made by the use of step-drawdown tests or by over-pumping at a rate large enough to dewater most of the wellbore. The maximum well yield, after overpumping, can be estimated from the rate of water-level recovery or by subtracting the incremental rate of change of borehole storage at the end of the test from the pumping rate.

  4. A High Frame Rate Test System for the HEPS-BPIX Based on NI-sbRIO Board

    NASA Astrophysics Data System (ADS)

    Gu, Jingzi; Zhang, Jie; Wei, Wei; Ning, Zhe; Li, Zhenjie; Jiang, Xiaoshan; Fan, Lei; Shen, Wei; Ren, Jiayi; Ji, Xiaolu; Lan, Allan K.; Lu, Yunpeng; Ouyang, Qun; Liu, Peng; Zhu, Kejun; Wang, Zheng

    2017-06-01

    HEPS-BPIX is a silicon pixel detector designed for the future large scientific facility, high-energy photon sources (HEPS) in Beijing, China. It is a high frame rate hybrid pixel detector which works in the single-photon-counting mode. High frame rate leads to much higher readout data bandwidth than former systems, which is also the difficulty of the design. Aiming to test and calibrate the pixel detector, a test system based on the National Instruments single-board RIO 9626 and LabVIEW program environment has been designed. A series of tests has been carried out with X-ray machine as well as on the Beijing Synchrotron Radiation Facility 1W2B beamline. The test results show that the threshold uniformity is better than 60 electrons and the equivalent noise charge is less than 120 electrons. Besides, the required highest frame rate of 1.2 kHz has been realized. This paper will elaborate the test system design and present the latest testing results of the HEPS-BPIX system.

  5. Experimental Assessment of the Reciprocating Feed System

    NASA Technical Reports Server (NTRS)

    Eddleman, David E.; Blackmon, James B.; Morton, Christopher D.

    2006-01-01

    The primary goal of this project was to design, construct, and test a full scale, high pressure simulated propellant feed system test bed that could evaluate the ability of the Reciprocating Feed System (RFS) to provide essentially constant flow rates and pressures to a rocket engine. The two key issues addressed were the effects of the transition of the drain cycle from tank to tank and the benefits of other hardware such as accumulators to provide a constant pressure flow rate out of the RFS. The test bed provided 500 psi flow at rates of the order of those required for engines in the 20,000 lbf thrust class (e.g., 20 to 40 lb/sec). A control system was developed in conjunction with the test article and automated system operation was achieved. Pre-test planning and acceptance activities such as a documented procedure and hazard analysis were conducted and the operation of the test article was approved by, and conducted in coordination with, appropriate NASA Marshall Space Flight Center personnel under a Space Act Agreement. Tests demonstrated successful control of flow rates and pressures.

  6. Interventions to Improve Rate of Diabetes Testing Postpartum in Women With Gestational Diabetes Mellitus.

    PubMed

    Hamel, Maureen S; Werner, Erika F

    2017-02-01

    Gestational diabetes mellitus (GDM) is one of the most common medical complications of pregnancy. In the USA, four million women are screened annually for GDM in pregnancy in part to improve pregnancy outcomes but also because diagnosis predicts a high risk of future type 2 diabetes mellitus (T2DM). Therefore, among women with GDM, postpartum care should be focused on T2DM prevention. This review describes the current literature aimed to increase postpartum diabetes testing among women with GDM. Data suggest that proactive patient contact via a health educator, a phone call, or even postal mail is associated with higher rates of postpartum diabetes testing. There may also be utility to changing the timing of postpartum diabetes testing. Despite the widespread knowledge regarding the importance of postpartum testing for women with GDM, testing rates remain low. Alternative testing strategies and large randomized trials addressing postpartum testing are warranted.

  7. Physiotherapist agreement when visually rating movement quality during lower extremity functional screening tests.

    PubMed

    Whatman, Chris; Hing, Wayne; Hume, Patria

    2012-05-01

    To investigate physiotherapist agreement in rating movement quality during lower extremity functional tests using two visual rating methods and physiotherapists with differing clinical experience. Clinical measurement. Six healthy individuals were rated by 44 physiotherapists. These raters were in three groups (inexperienced, novice, experienced). Video recordings of all six individuals performing four lower extremity functional tests were visually rated (dichotomous or ordinal scale) using two rating methods (overall or segment) on two occasions separated by 3-4 weeks. Intra and inter-rater agreement for physiotherapists was determined using overall percentage agreement (OPA) and the first order agreement coefficient (AC1). Intra-rater agreement for overall and segment methods ranged from slight to almost perfect (OPA: 29-96%, AC1: 0.01 to 0.96). AC1 agreement was better in the experienced group (84-99% likelihood) and for dichotomous rating (97-100% likelihood). Inter-rater agreement ranged from fair to good (OPA: 45-79%; AC1: 0.22-0.71). AC1 agreement was not influenced by clinical experience but was again better using dichotomous rating. Physiotherapists' visual rating of movement quality during lower extremity functional tests resulted in slight to almost perfect intra-rater agreement and fair to good inter-rater agreement. Agreement improved with increased level of clinical experience and use of dichotomous rating. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. A Finite Rate Chemical Analysis of Nitric Oxide Flow Contamination Effects on Scramjet Performance

    NASA Technical Reports Server (NTRS)

    Cabell, Karen F.; Rock, Kenneth E.

    2003-01-01

    The level of nitric oxide contamination in the test gas of the Langley Research Center Arc-Heated Scramjet Test Facility and the effect of the contamination on scramjet test engine performance were investigated analytically. A finite rate chemical analysis was performed to determine the levels of nitric oxide produced in the facility at conditions corresponding to Mach 6 to 8 flight simulations. Results indicate that nitric oxide levels range from one to three mole percent, corroborating previously obtained measurements. A three-stream combustor code with finite rate chemistry was used to investigate the effects of nitric oxide on scramjet performance. Results indicate that nitric oxide in the test gas causes a small increase in heat release and thrust performance for the test conditions investigated. However, a rate constant uncertainty analysis suggests that the effect of nitric oxide ranges from no net effect, to an increase of about 10 percent in thrust performance.

  9. The Impact of a Social Marketing Campaign on HIV and Sexually Transmissible Infection Testing Among Men Who Have Sex With Men in Australia.

    PubMed

    Wilkinson, Anna L; Pedrana, Alisa E; El-Hayek, Carol; Vella, Alyce M; Asselin, Jason; Batrouney, Colin; Fairley, Christopher K; Read, Tim R H; Hellard, Margaret; Stoové, Mark

    2016-01-01

    In response to increasing HIV and other sexually transmissible infection (HIV/STI) notifications in Australia, a social marketing campaign Drama Downunder (DDU) was launched in 2008 to promote HIV/STI testing among men who have sex with men (MSM). We analyzed prospective data from (1) an online cohort of MSM and (2) clinic-level HIV/STI testing to evaluate the impact of DDU on HIV, syphilis, gonorrhea, and chlamydia testing. (1) Cohort participants who completed 3 surveys (2010-2014) contributed to a Poisson regression model examining predictors of recent HIV testing.(2) HIV, syphilis, gonorrhea, and chlamydia tests among MSM attending high caseload primary care clinics (2007-2013) were included in an interrupted time series analysis. (1) Although campaign awareness was high among 242 MSM completing 726 prospective surveys, campaign recall was not associated with self-reported HIV testing. Reporting previous regular HIV testing (adjusted incidence rate ratio, 2.4; 95% confidence interval, 1.3-4.4) and more than 10 partners in the previous 6 months (adjusted incidence rate ratio, 1.2; 95% confidence interval, 1.1-1.4) was associated with recent HIV testing. (2) Analysis of 257,023 tests showed increasing monthly HIV, syphilis, gonorrhea, and chlamydia tests pre-DDU. Post-DDU, gonorrhea test rates increased significantly among HIV-negative MSM, with modest and nonsignificant increasing rates of HIV, syphilis, and chlamydia testing. Among HIV-positive MSM, no change in gonorrhea or chlamydia testing occurred and syphilis testing declined significantly. Increasing HIV/STI testing trends among MSM occurred pre- and post-DDU, coinciding with other plausible drivers of testing. Modest changes in HIV testing post-DDU suggest that structural changes to improve testing access may need to occur alongside health promotion to increase testing frequency.

  10. 14 CFR 61.405 - What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... flight instructor certificate with a sport pilot rating? 61.405 Section 61.405 Aeronautics and Space..., FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS Flight Instructors With a Sport Pilot Rating § 61.405 What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating? To obtain a...

  11. 14 CFR 61.405 - What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... flight instructor certificate with a sport pilot rating? 61.405 Section 61.405 Aeronautics and Space..., FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS Flight Instructors With a Sport Pilot Rating § 61.405 What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating? To obtain a...

  12. 14 CFR 61.405 - What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... flight instructor certificate with a sport pilot rating? 61.405 Section 61.405 Aeronautics and Space..., FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS Flight Instructors With a Sport Pilot Rating § 61.405 What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating? To obtain a...

  13. 40 CFR 63.1384 - Performance test requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... parameter. (3) During each performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during...

  14. 40 CFR 63.1384 - Performance test requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... parameter. (3) During each performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during...

  15. Crash test ratings and real-world frontal crash outcomes: a CIREN study.

    PubMed

    Ryb, Gabriel E; Burch, Cynthia; Kerns, Timothy; Dischinger, Patricia C; Ho, Shiu

    2010-05-01

    To establish whether the Insurance Institute for Highway Safety (IIHS) offset crash test ratings are linked to different mortality rates in real world frontal crashes. The study used Crash Injury Research Engineering Network drivers of age older than 15 years who were involved in frontal crashes. The Crash Injury Research Engineering Network is a convenience sample of persons injured in crashes with at least one Abbreviated Injury Scale score of 3+ injury or two Abbreviated Injury Scale score of 2+ injuries who were either treated at a Level I trauma center or died. Cases were grouped by IIHS crash test ratings (i.e., good, acceptable, marginal, poor, and not rated). Those rated marginal were excluded because of their small numbers. Mortality rates experienced by these ratings-based groups were compared using the Mantel-Haenszel chi test. Multiple logistic regression models were built to adjust for confounders (i.e., occupant, vehicular, and crash factors). A total of 1,226 cases were distributed within not rated (59%), poor (12%), average (16%), and good (14%) categories. Those rated good and average experienced a lower unadjusted mortality rate. After adjustment by confounders, those in vehicles rated good experienced a lower risk of death (adjusted OR 0.38 [0.16-0.90]) than those in vehicles rated poor. There was no significant effect for "acceptable" rating. Other factors influencing the occurrence of death were age, DeltaV >or=70 km/h, high body mass index, and lack of restraint use. After adjusting for occupant, vehicular, and crash factors, drivers of vehicles rated good by the IIHS experienced a lower risk of death in frontal crashes.

  16. First-language raters' opinions when validating word recordings for a newly developed speech reception threshold test.

    PubMed

    Panday, Seema; Kathard, Harsha; Pillay, Mershen; Wilson, Wayne

    2018-03-29

     The purpose of this study was to consider the value of adding first-language speaker ratings to the process of validating word recordings for use in a new speech reception threshold (SRT) test in audiology. Previous studies had identified 28 word recordings as being suitable for use in a new SRT test. These word recordings had been shown to satisfy the linguistic criteria of familiarity, phonetic dissimilarity and tone, and the psychometric criterion of homogeneity of audibility. Objectives: The aim of the study was to consider the value of adding first-language speakers' ratings when validating word recordings for a new SRT test. Method: A single observation, cross-sectional design was used to collect and analyse quantitative data in this study. Eleven first-language isiZulu speakers, purposively selected, were asked to rate each of the word recordings for pitch, clarity, naturalness, speech rate and quality on a 5-point Likert scale. The percent agreement and Friedman test were used for analysis. Results: More than 20% of these 11 participants rated the three-word recordings below 'strongly agree' in the category of pitch or tone, and one-word recording below 'strongly agree' in the categories of pitch or tone, clarity or articulation and naturalness or dialect. Conclusion: The first-language speaker ratings proved to be a valuable addition to the process of selecting word recordings for use in a new SRT test. In particular, these ratings identified potentially problematic word recordings in the new SRT test that had been missed by the previously and more commonly used linguistic and psychometric selection criteria.

  17. Autonomic Evaluation of Patients With Gastroparesis and Neurostimulation: Comparisons of Direct/Systemic and Indirect/Cardiac Measures

    PubMed Central

    Stocker, Abigail; Abell, Thomas L.; Rashed, Hani; Kedar, Archana; Boatright, Ben; Chen, Jiande

    2016-01-01

    Background Disorders of nausea, vomiting, abdominal pain, and related problems often are manifestations of gastrointestinal, neuromuscular, and/or autonomic dysfunction. Many of these patients respond to neurostimulation, either gastric electrical stimulation or electroacupuncture. Both of these therapeutic techniques appear to influence the autonomic nervous system which can be evaluated directly by traditional testing and indirectly by heart rate variability. Methods We studied patients undergoing gastric neuromodulation by both systemic autonomic testing (39 patients, six males and 33 females, mean age 38 years) and systemic autonomic testing and heart rate variability (35 patients, seven males and 28 females, mean age 37 years) testing before and after gastric neuromodulation. We also performed a pilot study using both systemic autonomic testing and heart rate variability in a small number of patients (five patients, all females, mean age 48.6 years) with diabetic gastroparesis at baseline to compare the two techniques at baseline. Systemic autonomic testing and heart rate variability were performed with standardized techniques and gastric electrical stimulation was performed as previously described with electrodes implanted serosally in the myenteric plexus. Results Both systemic autonomic testing and heart rate variability measures were often abnormal at baseline and showed changes after gastric neuromodulation therapy in two groups of symptomatic patients. Pilot data on a small group of similar patients with systemic automatic nervous measures and heart rate variability showed good concordance between the two techniques. Conclusions Both traditional direct autonomic measures and indirect measures such as heart rate variability were evaluated, including a pilot study of both methods in the same patient group. Both appear to be useful in evaluation of patients at baseline and after stimulation therapies; however, a future full head-to-head comparison is warranted. PMID:27785318

  18. Burning of CP Titanium (Grade 2) in Oxygen-Enriched Atmospheres

    NASA Technical Reports Server (NTRS)

    Stoltzfus, Joel M.; Jeffers, Nathan; Gallus, Timothy D.

    2012-01-01

    The flammability in oxygen-enriched atmospheres of commercially pure (CP) titanium rods as a function of diameter and test gas pressure was determined. Test samples of varying diameters were ignited at the bottom and burned upward in 70% O2/balance N2 and in 99.5+% O2 at various pressures. The burning rate of each ignited sample was determined by observing the apparent regression rate of the melting interface (RRMI) of the burning samples. The burning rate or RRMI increased with decreasing test sample diameter and with increasing test gas pressure and oxygen concentration

  19. Service evaluation of an educational intervention to improve sexual health services in primary care implemented using a step-wedge design: analysis of chlamydia testing and diagnosis rate changes.

    PubMed

    Town, Katy; McNulty, Cliodna A M; Ricketts, Ellie J; Hartney, Thomas; Nardone, Anthony; Folkard, Kate A; Charlett, Andre; Dunbar, J Kevin

    2016-08-02

    Providing sexual health services in primary care is an essential step towards universal provision. However they are not offered consistently. We conducted a national pilot of an educational intervention to improve staff's skills and confidence to increase chlamydia testing rates and provide condoms with contraceptive information plus HIV testing according to national guidelines, known as 3Cs&HIV. The effectiveness of the pilot on chlamydia testing and diagnosis rates in general practice was evaluated. The pilot was implemented using a step-wedge design over three phases during 2013 and 2014 in England. The intervention combined educational workshops with posters, testing performance feedback and continuous support. Chlamydia testing and diagnosis rates in participating general practices during the control and intervention periods were compared adjusting for seasonal trends in chlamydia testing and differences in practice size. Intervention effect modification was assessed for the following general practice characteristics: chlamydia testing rate compared to national median, number of general practice staff employed, payment for chlamydia screening, practice urban/rurality classification, and proximity to sexual health clinics. The 460 participating practices conducted 26,021 tests in the control period and 18,797 tests during the intervention period. Intention-to-treat analysis showed no change in the unadjusted median tests and diagnoses per month per practice after receiving training: 2.7 vs 2.7; 0.1 vs 0.1. Multivariable negative binomial regression analysis found no significant change in overall testing or diagnoses post-intervention (incidence rate ratio (IRR) 1.01, 95 % confidence interval (CI) 0.96-1.07, P = 0.72; 0.98 CI 0.84-1.15, P = 0.84, respectively). Stratified analysis showed testing increased significantly in practices where payments were in place prior to the intervention (IRR 2.12 CI 1.41-3.18, P < 0.001) and in practices with 6-15 staff (6-10 GPs IRR 1.35 (1.07-1.71), P = 0.012; 11-15 GPs IRR 1.37 (1.09-1.73), P = 0.007). This national pilot of short educational training sessions found no overall effect on chlamydia testing in primary care. However, in certain sub-groups chlamydia testing rates increased due to the intervention. This demonstrates the importance of piloting and evaluating any service improvement intervention to assess the impact before widespread implementation, and the need for detailed understanding of local services in order to select effective interventions.

  20. Criterion validation of two submaximal aerobic fitness tests, the self-monitoring Fox-walk test and the Åstrand cycle test in people with rheumatoid arthritis.

    PubMed

    Nordgren, Birgitta; Fridén, Cecilia; Jansson, Eva; Österlund, Ted; Grooten, Wilhelmus Johannes; Opava, Christina H; Rickenlund, Anette

    2014-09-17

    Aerobic capacity tests are important to evaluate exercise programs and to encourage individuals to have a physically active lifestyle. Submaximal tests, if proven valid and reliable could be used for estimation of maximal oxygen uptake (VO2max). The purpose of the study was to examine the criterion-validity of the submaximal self-monitoring Fox-walk test and the submaximal Åstrand cycle test against a maximal cycle test in people with rheumatoid arthritis (RA). A secondary aim was to study the influence of different formulas for age predicted maximal heart rate when estimating VO2max by the Åstrand test. Twenty seven subjects (81% female), mean (SD) age 62 (8.1) years, diagnosed with RA since 17.9 (11.7) years, participated in the study. They performed the Fox-walk test (775 meters), the Åstrand test and the maximal cycle test (measured VO2max test). Pearson's correlation coefficients were calculated to determine the direction and strength of the association between the tests, and paired t-tests were used to test potential differences between the tests. Bland and Altman methods were used to assess whether there was any systematic disagreement between the submaximal tests and the maximal test. The correlation between the estimated and measured VO2max values were strong and ranged between r = 0.52 and r = 0.82 including the use of different formulas for age predicted maximal heart rate, when estimating VO2max by the Åstrand test. VO2max was overestimated by 30% by the Fox-walk test and underestimated by 10% by the Åstrand test corrected for age. When the different formulas for age predicted maximal heart rate were used, the results showed that two formulas better predicted maximal heart rate and consequently a more precise estimation of VO2max. Despite the fact that the Fox-walk test overestimated VO2max substantially, the test is a promising method for self-monitoring VO2max and further development of the test is encouraged. The Åstrand test should be considered as highly valid and feasible and the two newly developed formulas for predicting maximal heart rate according to age are preferable to use when estimating VO2max by the Åstrand test.

  1. Control of rail integrity by self-adaptive scheduling of rail tests

    DOT National Transportation Integrated Search

    1990-06-01

    A guide for the scheduling of in-service tests of rail to detect defects is presented. The guide is designed for self-adaptation to changing track conditions, as reflected by the total rate of defect occurrence per test, the rate of 'service' defect ...

  2. 49 CFR 219.608 - FRA Administrator's determination of random alcohol testing rate.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alcohol testing rate. 219.608 Section 219.608 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.608 FRA Administrator's determination of random alcohol...

  3. 49 CFR 219.608 - FRA Administrator's determination of random alcohol testing rate.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... alcohol testing rate. 219.608 Section 219.608 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.608 FRA Administrator's determination of random alcohol...

  4. 49 CFR 219.608 - FRA Administrator's determination of random alcohol testing rate.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... alcohol testing rate. 219.608 Section 219.608 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.608 FRA Administrator's determination of random alcohol...

  5. 49 CFR 219.608 - FRA Administrator's determination of random alcohol testing rate.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... alcohol testing rate. 219.608 Section 219.608 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.608 FRA Administrator's determination of random alcohol...

  6. 49 CFR 219.608 - FRA Administrator's determination of random alcohol testing rate.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... alcohol testing rate. 219.608 Section 219.608 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.608 FRA Administrator's determination of random alcohol...

  7. Binning in Gaussian Kernel Regularization

    DTIC Science & Technology

    2005-04-01

    OSU-SVM Matlab package, the SVM trained on 966 bins has a comparable test classification rate as the SVM trained on 27,179 samples, but reduces the...71.40%) on 966 randomly sampled data. Using the OSU-SVM Matlab package, the SVM trained on 966 bins has a comparable test classification rate as the...the OSU-SVM Matlab package, the SVM trained on 966 bins has a comparable test classification rate as the SVM trained on 27,179 samples, and reduces

  8. Do Self Concept Tests Test Self Concept? An Evaluation of the Validity of Items on the Piers Harris and Coopersmith Measures.

    ERIC Educational Resources Information Center

    Lynch, Mervin D.; Chaves, John

    Items from Peirs-Harris and Coopersmith self-concept tests were evaluated against independent measures on three self-constructs, idealized, empathic, and worth. Construct measurements were obtained with the semantic differential and D statistic. Ratings were obtained from 381 children, grades 4-6. For each test, item ratings and construct measures…

  9. Frequency of HIV Testing among Persons with Disabilities: Results from the National Health Interview Survey, 2002

    ERIC Educational Resources Information Center

    Neri, Steven V.; Bradley, Elizabeth H.; Groce, Nora E.

    2007-01-01

    We examined rates of HIV testing of persons with disabilities relative to HIV testing rates of people without disabilities in the United States. Using data from the 2002 NHIS we examined the association between self-reported disability and having ever been tested for HIV. Adults with disability were more likely than nondisabled adults to report…

  10. Experimental evaluation of wall Mach number distributions of the octagonal test section proposed for NASA Lewis Research Center's altitude wind tunnel

    NASA Technical Reports Server (NTRS)

    Harrington, Douglas E.; Burley, Richard R.; Corban, Robert R.

    1986-01-01

    Wall Mach number distributions were determined over a range of test-section free-stream Mach numbers from 0.2 to 0.92. The test section was slotted and had a nominal porosity of 11 percent. Reentry flaps located at the test-section exit were varied from 0 (fully closed) to 9 (fully open) degrees. Flow was bled through the test-section slots by means of a plenum evacuation system (PES) and varied from 0 to 3 percent of tunnel flow. Variations in reentry flap angle or PES flow rate had little or no effect on the Mach number distributions in the first 70 percent of the test section. However, in the aft region of the test section, flap angle and PES flow rate had a major impact on the Mach number distributions. Optimum PES flow rates were nominally 2 to 2.5 percent wtih the flaps fully closed and less than 1 percent when the flaps were fully open. The standard deviation of the test-section wall Mach numbers at the optimum PES flow rates was 0.003 or less.

  11. Dynamic testing of a single-degree-of-freedom strapdown gyroscope

    NASA Technical Reports Server (NTRS)

    Lory, C. B.; Feldman, J.; Sinkiewicz, J. S., Jr.

    1971-01-01

    Test methods and results are presented for the equivalent average input rate of a single-degree-of-freedom gyroscope operated both open loop and with a ternary-logic pulse-torque-to-balance loop during multiaxis angular oscillation. For the open-loop tests, good agreement was obtained with theoretical results. Two-axis testing was performed for oscillations about the Input-Output axes, the Input-Spin axes, and the Spin-Output axes. These tests run in the torque-to-balance mode revealed significant departures from open-loop results in the induced drift rate. An analysis is developed explaining much of the closed-loop data presented. Test data for the gryoscope in a ternary torque-to-balance loop with constant input rates is presented. The tests demonstrate that the instrument rate linearity does not change with interrogation frequency from 3,600 to 14,400 Hz if the torque coil is tuned to offer a resistive load to the current switch. Analysis cited shows that gyroscope lag compensation eliminates multiple pulsing and other equivalent forms of degraded resolution in a wide variety of quantizing loops. This result is test verified for the ternary delta-modulator loop.

  12. Fertility, income distribution, and economic growth: theory and cross-country evidence.

    PubMed

    Galor, O; Zang, H

    1997-05-01

    The authors perform discriminatory, empirical tests of a theoretical model that predicts that family size adversely affects output per capita and nonsteady state growth rates. Neoclassical models posit that adverse output and nonsteady growth rates are affected by labor force growth (LFG) or population growth (PG). This study tests whether family size (FS) will be more significant than LFG or PG in explaining differences in economic growth (EG) rates across countries during 1960-88. A proxy variable for the public education system was used to separate government interventions on human capital formation from market forces. Data were obtained for 73 countries, which exclude centrally planned economies, oil-producing countries, and those with less than 1 million population. The empirical test is run with 58-country, 45-country, and 96-country samples to test for robustness and reliability. The empirical test supports the theoretical model. It demonstrates that equal distribution of income and smaller FS enhance EG. With income inequality, the effect of FS was significant, and the effect of the LFG rate or PG rate was insignificant. With a given FS, LFG was positively correlated with EG. A reduction of the net fertility rate by one point would increase the worker output growth rate by 0.25%, and the differences in growth rates between high- and low-fertility countries would be 1%. An increase in the income share of the bottom 60% would increase the growth rate of worker output by about 1%. Higher investments in public or private education would be conducive to growth.

  13. Total Ionizing Dose Test of Microsemi's Silicon Switching Transistors JANTXV2N2222AUB and 2N2907AUB

    NASA Technical Reports Server (NTRS)

    Campola, M.; Freeman, B.; Yau, K.

    2017-01-01

    Microsemi's silicon switching transistors, JANTXV2N2222AUB and 2N2907AUB, were tested for total ionizing dose (TID) response beginning on July 11, 2016. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

  14. Dynamic Brazilian Test of Rock Under Intermediate Strain Rate: Pendulum Hammer-Driven SHPB Test and Numerical Simulation

    NASA Astrophysics Data System (ADS)

    Zhu, W. C.; Niu, L. L.; Li, S. H.; Xu, Z. H.

    2015-09-01

    The tensile strength of rock subjected to dynamic loading constitutes many engineering applications such as rock drilling and blasting. The dynamic Brazilian test of rock specimens was conducted with the split Hopkinson pressure bar (SHPB) driven by pendulum hammer, in order to determine the indirect tensile strength of rock under an intermediate strain rate ranging from 5.2 to 12.9 s-1, which is achieved when the incident bar is impacted by pendulum hammer with different velocities. The incident wave excited by pendulum hammer is triangular in shape, featuring a long rising time, and it is considered to be helpful for achieving a constant strain rate in the rock specimen. The dynamic indirect tensile strength of rock increases with strain rate. Then, the numerical simulator RFPA-Dynamics, a well-recognized software for simulating the rock failure under dynamic loading, is validated by reproducing the Brazilian test of rock when the incident stress wave retrieved at the incident bar is input as the boundary condition, and then it is employed to study the Brazilian test of rock under the higher strain rate. Based on the numerical simulation, the strain-rate dependency of tensile strength and failure pattern of the Brazilian disc specimen under the intermediate strain rate are numerically simulated, and the associated failure mechanism is clarified. It is deemed that the material heterogeneity should be a reason for the strain-rate dependency of rock.

  15. A music quality rating test battery for cochlear implant users to compare the FSP and HDCIS strategies for music appreciation.

    PubMed

    Looi, Valerie; Winter, Philip; Anderson, Ilona; Sucher, Catherine

    2011-08-01

    The purpose of this study was to develop a music quality rating test battery (MQRTB) and pilot test it by comparing appraisal ratings from cochlear implant (CI) recipients using the fine-structure processing (FSP) and high-definition continuous interleaved sampling (HDCIS) speech processing strategies. The development of the MQRTB involved three stages: (1) Selection of test items for the MQRTB; (2) Verification of its length and complexity with normally-hearing individuals; and (3) Pilot testing with CI recipients. Part 1 involved 65 adult listeners, Part 2 involved 10 normally-hearing adults, and Part 3 involved five adult MED-EL CI recipients. The MQRTB consisted of ten songs, with ratings made on scales assessing pleasantness, naturalness, richness, fullness, sharpness, and roughness. Results of the pilot study, which compared FSP and HDCIS for music, indicated that acclimatization to a strategy had a significant effect on ratings (p < 0.05). When acclimatized to FSP, the group rated FSP as closer to 'exactly as I want it to sound' than HDCIS (p < 0.05), and that HDCIS sounded significantly sharper and rougher than FSP. However when acclimatized to HDCIS, there were no significant differences between ratings. There was no effect of song familiarity or genre on ratings. Overall the results suggest that the use of FSP as the default strategy for MED-EL recipients would have a positive effect on music appreciation, and that the MQRTB is an effective tool for assessing music sound quality.

  16. Hepatitis C Testing Increased Among Baby Boomers Following The 2012 Change To CDC Testing Recommendations.

    PubMed

    Barocas, Joshua A; Wang, Jianing; White, Laura F; Tasillo, Abriana; Salomon, Joshua A; Freedberg, Kenneth A; Linas, Benjamin P

    2017-12-01

    In 2012 the Centers for Disease Control and Prevention recommended routine testing for hepatitis C for people born in the period 1945-65. Until now, the recommendation's impact on hepatitis C screening rates in the United States has not been fully understood. We used an interrupted time series with comparison group design to analyze hepatitis C screening rates in the period 2010-14 among 2.8 million commercially insured adults in the MarketScan database. Hepatitis C screening rates increased yearly between 2010 and 2014, from 1.65 to 2.59 per 100 person-years. A 49 percent increase in screening rates among people born during 1945-65 followed the release of the recommendation, but no such increase was observed among adults born after 1965. The effect among the target population was sustained, and by twenty-four months after the recommendation's release, screening rates had increased 106 percent. We conclude that the hepatitis C testing policy change resulted in significantly increased testing among the target population and may have decreased the magnitude of the hepatitis C epidemic.

  17. Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests

    NASA Technical Reports Server (NTRS)

    Stout, Cynthia S.; Toscano, William B.; Cowings, Patricia S.

    1993-01-01

    There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.

  18. Test Performance and Test-Retest Reliability of the Vestibular/Ocular Motor Screening and King-Devick Test in Adolescent Athletes During a Competitive Sport Season.

    PubMed

    Worts, Phillip R; Schatz, Philip; Burkhart, Scott O

    2018-05-01

    The Vestibular/Ocular Motor Screening (VOMS) and King-Devick (K-D) test are tools designed to assess ocular or vestibular function after a sport-related concussion. To determine the test-retest reliability and rate of false-positive results of the VOMS and K-D test in a healthy athlete sample. Cohort study (diagnosis); Level of evidence, 2. Forty-five healthy high school student-athletes (mean age, 16.11 ± 1.43 years) completed self-reported demographics and medical history and were administered the VOMS and K-D test during rest on day 1 (baseline). The VOMS and K-D test were administered again once during rest (prepractice) and once within 5 minutes of removal from sport practice on day 2 (removal). The Borg rating of perceived exertion scale was administered at removal. Intraclass correlation coefficients were used to determine test-retest reliability on the K-D test and the average near point of convergence (NPC) distance on the VOMS. Level of agreement was used to examine VOMS symptom provocation over the 3 administration times. Multivariate base rates were used to determine the rate of false-positive results when simultaneously considering multiple clinical cutoffs. Test-retest reliability of total time on the K-D test (0.91 [95% CI, 0.86-0.95]) and NPC distance (0.91 [95% CI, 0.85-0.95]) was high across the 3 administration times. Level of agreement ranged from 48.9% to 88.9% across all 3 times for the VOMS items. Using established clinical cutoffs, false-positive results occurred in 2% of the sample using the VOMS at removal and 36% using the K-D test. The VOMS displayed a false-positive rate of 2% in this high school student-athlete cohort. The K-D test's false-positive rate was 36% while maintaining a high level of test-retest reliability (0.91). Results from this study support future investigation of VOMS administration in an acutely injured high school athletic sample. Going forward, the VOMS may be more stable than other neurological and symptom report screening measures and less vulnerable to false-positive results than the K-D test.

  19. First-trimester contingent screening for trisomies 21, 18 and 13 by biomarkers and maternal blood cell-free DNA testing.

    PubMed

    Nicolaides, K H; Syngelaki, A; Poon, L C; Gil, M M; Wright, D

    2014-01-01

    To examine potential performance of screening for trisomies by cell-free (cf) DNA testing in maternal blood contingent on results of first-line testing by combinations of fetal translucency thickness (NT), fetal heart rate (FHR), ductus venosus pulsatility index (DV PIV), and serum-free β-human chorionic gonadotropin (β-hCG), pregnancy-associated plasma protein-A (PAPP-A), placental growth factor (PLGF) and α-fetoprotein (AFP). Performance was estimated for firstly, screening by cfDNA in all pregnancies and secondly, cfDNA testing contingent on results of first-line testing by combinations of ultrasound and biochemical markers. In first-line screening by cfDNA testing, the detection rate for trisomy 21 and trisomies 18 or 13 would be 99 and 96%, respectively, after invasive testing in 1% of the population. In contingent screening, a detection rate of 98% for trisomy 21 and 96% for trisomy 18 or 13, at an invasive testing rate of 0.7%, can be achieved by carrying out cfDNA testing in about 35, 20 and 11% of cases identified by first-line screening with the combined test alone (age, NT, FHR, β-hCG, PAPP-A), the combined test plus PLGF and AFP and the combined test plus PLGF, AFP and DV PIV, respectively. Effective first-trimester screening for trisomies can be achieved by contingent screening incorporating biomarkers and cfDNA testing. © 2013 S. Karger AG, Basel.

  20. Life Prediction/Reliability Data of Glass-Ceramic Material Determined for Radome Applications

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    2002-01-01

    Brittle materials, ceramics, are candidate materials for a variety of structural applications for a wide range of temperatures. However, the process of slow crack growth, occurring in any loading configuration, limits the service life of structural components. Therefore, it is important to accurately determine the slow crack growth parameters required for component life prediction using an appropriate test methodology. This test methodology also should be useful in determining the influence of component processing and composition variables on the slow crack growth behavior of newly developed or existing materials, thereby allowing the component processing and composition to be tailored and optimized to specific needs. Through the American Society for Testing and Materials (ASTM), the authors recently developed two test methods to determine the life prediction parameters of ceramics. The two test standards, ASTM 1368 for room temperature and ASTM C 1465 for elevated temperatures, were published in the 2001 Annual Book of ASTM Standards, Vol. 15.01. Briefly, the test method employs constant stress-rate (or dynamic fatigue) testing to determine flexural strengths as a function of the applied stress rate. The merit of this test method lies in its simplicity: strengths are measured in a routine manner in flexure at four or more applied stress rates with an appropriate number of test specimens at each applied stress rate. The slow crack growth parameters necessary for life prediction are then determined from a simple relationship between the strength and the applied stress rate. Extensive life prediction testing was conducted at the NASA Glenn Research Center using the developed ASTM C 1368 test method to determine the life prediction parameters of a glass-ceramic material that the Navy will use for radome applications.

  1. An extended sequential goodness-of-fit multiple testing method for discrete data.

    PubMed

    Castro-Conde, Irene; Döhler, Sebastian; de Uña-Álvarez, Jacobo

    2017-10-01

    The sequential goodness-of-fit (SGoF) multiple testing method has recently been proposed as an alternative to the familywise error rate- and the false discovery rate-controlling procedures in high-dimensional problems. For discrete data, the SGoF method may be very conservative. In this paper, we introduce an alternative SGoF-type procedure that takes into account the discreteness of the test statistics. Like the original SGoF, our new method provides weak control of the false discovery rate/familywise error rate but attains false discovery rate levels closer to the desired nominal level, and thus it is more powerful. We study the performance of this method in a simulation study and illustrate its application to a real pharmacovigilance data set.

  2. A likelihood ratio test for evolutionary rate shifts and functional divergence among proteins

    PubMed Central

    Knudsen, Bjarne; Miyamoto, Michael M.

    2001-01-01

    Changes in protein function can lead to changes in the selection acting on specific residues. This can often be detected as evolutionary rate changes at the sites in question. A maximum-likelihood method for detecting evolutionary rate shifts at specific protein positions is presented. The method determines significance values of the rate differences to give a sound statistical foundation for the conclusions drawn from the analyses. A statistical test for detecting slowly evolving sites is also described. The methods are applied to a set of Myc proteins for the identification of both conserved sites and those with changing evolutionary rates. Those positions with conserved and changing rates are related to the structures and functions of their proteins. The results are compared with an earlier Bayesian method, thereby highlighting the advantages of the new likelihood ratio tests. PMID:11734650

  3. Herpes

    MedlinePlus

    ... Testing Epstein-Barr Virus (EBV) Antibody Tests Erythrocyte Sedimentation Rate (ESR) Erythropoietin Estimated Glomerular Filtration Rate (eGFR) ... Available online at http://health.lifestyle.yahoo.ca/channel_section_details.asp?text_id=1364&channel_id= ...

  4. Nickel-hydrogen battery state of charge during low rate trickle charging

    NASA Technical Reports Server (NTRS)

    Lurie, C.; Foroozan, S.; Brewer, J.; Jackson, L.

    1995-01-01

    Battery temperature increase, due to low rate trickle charging, has been determined experimentally, using a six cell battery module in a test setup simulating the anticipated AXAF-1 prelaunch environment. Test results indicate trickle charge rates less than or equal to the self discharge rate do not increase dissipation beyond that due to the self discharge. Significant trickle charge rates (approximately C/500) result in battery temperatures only a few degrees (F) higher than those observed during periods of open circuit stand.

  5. Respiratory protection against Mycobacterium tuberculosis: quantitative fit test outcomes for five type N95 filtering-facepiece respirators.

    PubMed

    Lee, Kiyoung; Slavcev, Andrea; Nicas, Mark

    2004-01-01

    In preparing to fit test a large workforce, a respirator program manager needs to initially choose respirators that will fit the greatest proportion of employees and achieve the best fits. This article discusses our strategy in selecting respirators from an initial array of seven NIOSH-certified Type N95 filtering-facepiece devices for a respiratory protection program against Mycobacterium tuberculosis (M. tb) aerosol. The seven respirators were screened based on manufacturer-provided fit test data, comfort, and cost. From these 7 devices, 5 were chosen for quantitative fit testing on 40 subjects who were a convenience sample from a cohort of approximately 30,000 workers scheduled to undergo fit testing. Across the five brands, medium/regular-size respirators fit from 8% to 95% of the subjects; providing another size of the same brand improved the pass rates slightly. Gender was not found to significantly affect fit test pass rates for any respirator brand. Among test panel members, an Aearo Corporation respirator (TC 84A-2630) and a 3M Company respirator (TC 84A-0006) provided the highest overall pass rates of 98% and 90%, respectively. We selected these two brands for fit testing in the larger worker cohort. To date, these two respirators have provided overall pass rates of 98% (1793/1830) and 88% (50/57), respectively, which are similar to the test panel results. Among 1850 individuals who have been fit tested, 1843 (99.6%) have been successfully fitted with one or the other brand. In a separate analysis, we used the test panel pass rates to estimate the reduction in M. tb infection risk afforded by the medium/regular-size of five filtering-facepiece respirators. We posed a low-exposure versus a high-exposure scenario for health care workers and assumed that respirators could be assigned without conducting fit testing, as proposed by many hospital infection control practitioners. Among those who would pass versus fail the fit test, we assumed an average respirator penetration (primarily due to faceseal leakage) of .04 and 0.3, respectively. The respirator with the highest overall pass rate (95%) reduced M. tb infection risk by 95%, while the respirator with the lowest pass rate (8%) reduced M. tb infection risk by only 70%. To promote the marketing of respirators that will successfully fit the highest proportion of wearers, and to increase protection for workers who might use respirators without the benefit of being fit tested, we recommend that fit testing be part of the NIOSH certification process for negative-pressure air-purifying respirators with tightly fitting facepieces. At a minimum, we recommend that respirator manufacturers generate and provide pass rate data to assist in selecting candidate respirators. In any event, program managers can initially select candidate respirators by comparing quantitative fit tests for a representative sample of their employee population.

  6. TEST METHODS TO CHARACTERIZE PARTICULATE MATTER EMISSIONS AND DEPOSITION RATES IN A RESEARCH HOUSE

    EPA Science Inventory

    The paper discusses test methods to characterize particulate matter (PM) emissions and deposition rates in a research house. In a room in the research house, specially configured for PM source testing, a high-efficiency particulate air (HEPA)-filtered air supply system, used for...

  7. 76 FR 28131 - Federal Motor Vehicle Safety Standards; Motorcycle Helmets

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ..., this final rule sets a quasi-static load application rate for the helmet retention system; revises the... Analysis and Conclusion e. Quasi-Static Retention Test f. Helmet Conditioning Tolerances g. Other... it as a quasi-static test, instead of a static test. Specifying the application rate will aid...

  8. An assessment of false positive rates for malaria rapid diagnostic tests caused by non-Plasmodium infectious agents and immunological factors.

    PubMed

    Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J

    2018-01-01

    Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.

  9. Effect of Control Mode and Test Rate on the Measured Fracture Toughness of Advanced Ceramics

    NASA Technical Reports Server (NTRS)

    Hausmann, Bronson D.; Salem, Jonathan A.

    2018-01-01

    The effects of control mode and test rate on the measured fracture toughness of ceramics were evaluated by using chevron-notched flexure specimens in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% (statistically insignificant) variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or crack mouth opening displacement (CMOD) control gave approx. 5% (statistically significant) variation over a very wide range of rates (1 to 80 µm/m/s), with the measurements being a function of rate. However, the rate effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of a nitrogen environment during strain controlled tests, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micons/m/s). CMOD or strain control did allow stable crack extension well past maximum force, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM Test Method C1421 on fracture toughness measurement.

  10. Stationarity test with a direct test for heteroskedasticity in exchange rate forecasting models

    NASA Astrophysics Data System (ADS)

    Khin, Aye Aye; Chau, Wong Hong; Seong, Lim Chee; Bin, Raymond Ling Leh; Teng, Kevin Low Lock

    2017-05-01

    Global economic has been decreasing in the recent years, manifested by the greater exchange rates volatility on international commodity market. This study attempts to analyze some prominent exchange rate forecasting models on Malaysian commodity trading: univariate ARIMA, ARCH and GARCH models in conjunction with stationarity test on residual diagnosis direct testing of heteroskedasticity. All forecasting models utilized the monthly data from 1990 to 2015. Given a total of 312 observations, the data used to forecast both short-term and long-term exchange rate. The forecasting power statistics suggested that the forecasting performance of ARIMA (1, 1, 1) model is more efficient than the ARCH (1) and GARCH (1, 1) models. For ex-post forecast, exchange rate was increased from RM 3.50 per USD in January 2015 to RM 4.47 per USD in December 2015 based on the baseline data. For short-term ex-ante forecast, the analysis results indicate a decrease in exchange rate on 2016 June (RM 4.27 per USD) as compared with 2015 December. A more appropriate forecasting method of exchange rate is vital to aid the decision-making process and planning on the sustainable commodities' production in the world economy.

  11. Performance-based tests versus behavioral ratings in the assessment of executive functioning in preschoolers: associations with ADHD symptoms and reading achievement.

    PubMed

    Miranda, Ana; Colomer, Carla; Mercader, Jessica; Fernández, M Inmaculada; Presentación, M Jesús

    2015-01-01

    The early assessment of the executive processes using ecologically valid instruments is essential for identifying deficits and planning actions to deal with possible adverse consequences. The present study has two different objectives. The first objective is to analyze the relationship between preschoolers' performance on tests of Working Memory and Inhibition and parents' and teachers' ratings of these executive functions (EFs) using the Behavior Rating Inventory of Executive Function (BRIEF). The second objective consists of studying the predictive value of the different EF measures (performance-based test and rating scales) on Inattention and Hyperactivity/Impulsivity behaviors and on indicators of word reading performance. The participants in the study were 209 children in the last year of preschool, their teachers and their families. Performance-based tests of Working Memory and Inhibition were administered, as well as word reading measures (accuracy and speed). The parents and teachers filled out rating scales of the EF and typical behaviors of attention deficit hyperactivity disorder (ADHD) symptomatology. Moderate correlation values were found between the different EF assessments procedures, although the results varied depending on the different domains. Metacognition Index from the BRIEF presented stronger correlations with verbal working memory tests than with inhibition tests. Both the rating scales and the performance-based tests were significant predictors of Inattention and Hyperactivity/Impulsivity behaviors and the reading achievement measures. However, the BRIEF explained a greater percentage of variance in the case of the ADHD symptomatology, while the performance-based tests explained reading achievement to a greater degree. The implications of the findings for research and clinical practice are discussed.

  12. The Generation Rate of Respirable Dust from Cutting Fiber Cement Siding Using Different Tools

    PubMed Central

    Qi, Chaolong; Echt, Alan; Gressel, Michael G

    2017-01-01

    This article describes the evaluation of the generation rate of respirable dust (GAPS, defined as the mass of respirable dust generated per unit linear length cut) from cutting fiber cement siding using different tools in a laboratory testing system. We used an aerodynamic particle sizer spectrometer (APS) to continuously monitor the real-time size distributions of the dust throughout cutting tests when using a variety of tools, and calculated the generation rate of respirable dust for each testing condition using the size distribution data. The test result verifies that power shears provided an almost dust-free operation with a GAPS of 0.006 gram meter−1 (g m−1) at the testing condition. For the same power saws, the cuts using saw blades with more teeth generated more respirable dusts. Using the same blade for all four miter saws tested in this study, a positive linear correlation was found between the saws’ blade rotating speed and its dust generation rate. In addition, a circular saw running at the highest blade rotating speed of 9068 RPM generated the greatest amount of dust. All the miter saws generated less dust in the ‘chopping mode’ than in the ‘chopping and sliding’ mode. For the tested saws, GAPS consistently decreased with the increases of the saw cutting feed rate and the number of board in the stack. All the test results point out that fewer cutting interactions between the saw blade’s teeth and the siding board for a unit linear length of cut tend to result in a lower generation rate of respirable dust. These results may help guide optimal operation in practice and future tool development aimed at minimizing dust generation while producing a satisfactory cut. PMID:28395343

  13. The Generation Rate of Respirable Dust from Cutting Fiber Cement Siding Using Different Tools.

    PubMed

    Qi, Chaolong; Echt, Alan; Gressel, Michael G

    2017-03-01

    This article describes the evaluation of the generation rate of respirable dust (GAPS, defined as the mass of respirable dust generated per unit linear length cut) from cutting fiber cement siding using different tools in a laboratory testing system. We used an aerodynamic particle sizer spectrometer (APS) to continuously monitor the real-time size distributions of the dust throughout cutting tests when using a variety of tools, and calculated the generation rate of respirable dust for each testing condition using the size distribution data. The test result verifies that power shears provided an almost dust-free operation with a GAPS of 0.006 g m-1 at the testing condition. For the same power saws, the cuts using saw blades with more teeth generated more respirable dusts. Using the same blade for all four miter saws tested in this study, a positive linear correlation was found between the saws' blade rotating speed and its dust generation rate. In addition, a circular saw running at the highest blade rotating speed of 9068 rpm generated the greatest amount of dust. All the miter saws generated less dust in the 'chopping mode' than in the 'chopping and sliding' mode. For the tested saws, GAPS consistently decreased with the increases of the saw cutting feed rate and the number of board in the stack. All the test results point out that fewer cutting interactions between the saw blade's teeth and the siding board for a unit linear length of cut tend to result in a lower generation rate of respirable dust. These results may help guide optimal operation in practice and future tool development aimed at minimizing dust generation while producing a satisfactory cut. Published by Oxford University Press on behalf of The British Occupational Hygiene Society 2017.

  14. Performance-based tests versus behavioral ratings in the assessment of executive functioning in preschoolers: associations with ADHD symptoms and reading achievement

    PubMed Central

    Miranda, Ana; Colomer, Carla; Mercader, Jessica; Fernández, M. Inmaculada; Presentación, M. Jesús

    2015-01-01

    The early assessment of the executive processes using ecologically valid instruments is essential for identifying deficits and planning actions to deal with possible adverse consequences. The present study has two different objectives. The first objective is to analyze the relationship between preschoolers’ performance on tests of Working Memory and Inhibition and parents’ and teachers’ ratings of these executive functions (EFs) using the Behavior Rating Inventory of Executive Function (BRIEF). The second objective consists of studying the predictive value of the different EF measures (performance-based test and rating scales) on Inattention and Hyperactivity/Impulsivity behaviors and on indicators of word reading performance. The participants in the study were 209 children in the last year of preschool, their teachers and their families. Performance-based tests of Working Memory and Inhibition were administered, as well as word reading measures (accuracy and speed). The parents and teachers filled out rating scales of the EF and typical behaviors of attention deficit hyperactivity disorder (ADHD) symptomatology. Moderate correlation values were found between the different EF assessments procedures, although the results varied depending on the different domains. Metacognition Index from the BRIEF presented stronger correlations with verbal working memory tests than with inhibition tests. Both the rating scales and the performance-based tests were significant predictors of Inattention and Hyperactivity/Impulsivity behaviors and the reading achievement measures. However, the BRIEF explained a greater percentage of variance in the case of the ADHD symptomatology, while the performance-based tests explained reading achievement to a greater degree. The implications of the findings for research and clinical practice are discussed. PMID:25972833

  15. Scale factor measure method without turntable for angular rate gyroscope

    NASA Astrophysics Data System (ADS)

    Qi, Fangyi; Han, Xuefei; Yao, Yanqing; Xiong, Yuting; Huang, Yuqiong; Wang, Hua

    2018-03-01

    In this paper, a scale factor test method without turntable is originally designed for the angular rate gyroscope. A test system which consists of test device, data acquisition circuit and data processing software based on Labview platform is designed. Taking advantage of gyroscope's sensitivity of angular rate, a gyroscope with known scale factor, serves as a standard gyroscope. The standard gyroscope is installed on the test device together with a measured gyroscope. By shaking the test device around its edge which is parallel to the input axis of gyroscope, the scale factor of the measured gyroscope can be obtained in real time by the data processing software. This test method is fast. It helps test system miniaturized, easy to carry or move. Measure quarts MEMS gyroscope's scale factor multi-times by this method, the difference is less than 0.2%. Compare with testing by turntable, the scale factor difference is less than 1%. The accuracy and repeatability of the test system seems good.

  16. HIV counselling and testing practices for children seen in an urban emergency department of a tertiary referral hospital in Dar es Salaam, Tanzania: a retrospective cross-sectional study.

    PubMed

    Sawe, Hendry R; Mfinanga, Juma A; Ringo, Faith H; Mwafongo, Victor; Reynolds, Teri A; Runyon, Michael S

    2016-02-15

    To describe the HIV counselling and testing practices for children presenting to an emergency department (ED) in a low-income country. The ED of a large east African national referral hospital. This retrospective review of all paediatric (<18 years old) ED visits in 2012 enrolled patients who had an HIV test ordered and excluded those without testing. Files were available for 5540/5774 (96%) eligible patients and 1632 (30%) were tested for HIV, median age 1.3 years (IQR 9 months to 4 years), 58% <18 months old and 61% male. The primary outcome measure was documentation of pretest and post-test counselling, or deferral of counselling, for children tested for HIV in the ED. Secondary measures included the overall rate of HIV testing, rate of counselling documented in the inpatient record when deferred in the ED, rate of counselling documented when testing was initiated by the inpatient service, rate of counselling documented by test result (positive vs negative) and the rate of referral to follow-up HIV care among patients testing positive. Of 418 patients tested in the ED, counselling, or deferral of counselling, was documented for 70 (17%). When deferred to the ward, subsequent counselling was documented for 15/42 (36%). Counselling was documented in 33% of patients testing positive versus 1.1% patients testing negative (OR 43 (95% CI 23 to 83). Of 199 patients who tested positive and survived to hospital discharge, 76 (38%) were referred for follow-up at the HIV clinic on discharge. Physicians documented the provision, or deferral, of counselling for <20% of children tested for HIV in the ED. Counselling was much more likely to be documented when the test result was positive. Less than 40% of those testing positive were referred for follow-up care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Working with Sparse Data in Rated Language Tests: Generalizability Theory Applications

    ERIC Educational Resources Information Center

    Lin, Chih-Kai

    2017-01-01

    Sparse-rated data are common in operational performance-based language tests, as an inevitable result of assigning examinee responses to a fraction of available raters. The current study investigates the precision of two generalizability-theory methods (i.e., the rating method and the subdividing method) specifically designed to accommodate the…

  18. Sex Ratios, Economic Power, and Women's Roles: A Theoretical Extension and Empirical Test.

    ERIC Educational Resources Information Center

    South, Scott J.

    1988-01-01

    Tested hypotheses concerning sex ratios, women's roles, and economic power with data from 111 countries. Found undersupply of women positively associated with proportion of women who marry and fertility rate; inversely associated with women's average age at marriage, literacy rate, and divorce rate. Suggests women's economic power may counteract…

  19. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...

  20. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...

  1. GAS-PHASE MASS TRANSFER MODEL FOR PREDICTING VOLATILE ORGANIC COMPOUND (VOC) EMISSION RATES FROM INDOOR POLLUTANT SOURCES

    EPA Science Inventory

    Analysis of the impact of sources on indoor pollutant concentrations and occupant exposure to indoor pollutants requires knowledge of the emission rates from the sources. Emission rates are often determined by chamber testing and the data from the chamber test are fitted to an em...

  2. 40 CFR 63.1656 - Performance testing, test methods, and compliance demonstrations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... points. (2) Method 2 to determine the volumetric flow rate of the stack gas. (3) Method 3 to determine... matter concentration and volumetric flow rate of the stack gas for positive pressure baghouses without...) Determine the particulate matter concentration and volumetric flow rate using Method 5 or 5D, as applicable...

  3. 40 CFR 63.1656 - Performance testing, test methods, and compliance demonstrations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... points. (2) Method 2 to determine the volumetric flow rate of the stack gas. (3) Method 3 to determine... matter concentration and volumetric flow rate of the stack gas for positive pressure baghouses without...) Determine the particulate matter concentration and volumetric flow rate using Method 5 or 5D, as applicable...

  4. 40 CFR 63.1656 - Performance testing, test methods, and compliance demonstrations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... points. (2) Method 2 to determine the volumetric flow rate of the stack gas. (3) Method 3 to determine... matter concentration and volumetric flow rate of the stack gas for positive pressure baghouses without...) Determine the particulate matter concentration and volumetric flow rate using Method 5 or 5D, as applicable...

  5. Calorimeter measures high nuclear heating rates and their gradients across a reactor test hole

    NASA Technical Reports Server (NTRS)

    Burwell, D.; Coombe, J. R.; Mc Bride, J.

    1970-01-01

    Pedestal-type calorimeter measures gamma-ray heating rates from 0.5 to 7.0 watts per gram of aluminum. Nuclear heating rate is a function of cylinder temperature change, measured by four chromel-alumel thermocouples attached to the calorimeter, and known thermoconductivity of the tested material.

  6. Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

    NASA Technical Reports Server (NTRS)

    Olson, Sandra

    2011-01-01

    To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

  7. Development of a high sensitivity pinhole type gamma camera using semiconductors for low dose rate fields

    NASA Astrophysics Data System (ADS)

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Yoshida, Akira; Umegaki, Kikuo

    2018-06-01

    We developed a pinhole type gamma camera, using a compact detector module of a pixelated CdTe semiconductor, which has suitable sensitivity and quantitative accuracy for low dose rate fields. In order to improve the sensitivity of the pinhole type semiconductor gamma camera, we adopted three methods: a signal processing method to set the discriminating level lower, a high sensitivity pinhole collimator and a smoothing image filter that improves the efficiency of the source identification. We tested basic performances of the developed gamma camera and carefully examined effects of the three methods. From the sensitivity test, we found that the effective sensitivity was about 21 times higher than that of the gamma camera for high dose rate fields which we had previously developed. We confirmed that the gamma camera had sufficient sensitivity and high quantitative accuracy; for example, a weak hot spot (0.9 μSv/h) around a tree root could be detected within 45 min in a low dose rate field test, and errors of measured dose rates with point sources were less than 7% in a dose rate accuracy test.

  8. DSN telemetry system performance using a maximum likelihood convolutional decoder

    NASA Technical Reports Server (NTRS)

    Benjauthrit, B.; Kemp, R. P.

    1977-01-01

    Results are described of telemetry system performance testing using DSN equipment and a Maximum Likelihood Convolutional Decoder (MCD) for code rates 1/2 and 1/3, constraint length 7 and special test software. The test results confirm the superiority of the rate 1/3 over that of the rate 1/2. The overall system performance losses determined at the output of the Symbol Synchronizer Assembly are less than 0.5 db for both code rates. Comparison of the performance is also made with existing mathematical models. Error statistics of the decoded data are examined. The MCD operational threshold is found to be about 1.96 db.

  9. Effects of Test Level Discrimination and Difficulty on Answer-Copying Indices

    ERIC Educational Resources Information Center

    Sunbul, Onder; Yormaz, Seha

    2018-01-01

    In this study Type I Error and the power rates of omega (?) and GBT (generalized binomial test) indices were investigated for several nominal alpha levels and for 40 and 80-item test lengths with 10,000-examinee sample size under several test level restrictions. As a result, Type I error rates of both indices were found to be below the acceptable…

  10. Implementing a Standardized Social Networks Testing Strategy in a Low HIV Prevalence Jurisdiction.

    PubMed

    Schumann, Casey; Kahn, Danielle; Broaddus, Michelle; Dougherty, Jacob; Elderbrook, Megan; Vergeront, James; Westergaard, Ryan

    2018-05-15

    Alternative HIV testing strategies are needed to engage individuals not reached by traditional clinical or non-clinical testing programs. A social networks recruitment strategy, in which people at risk for or living with HIV are enlisted and trained by community-based agencies to recruit individuals from their social, sexual, or drug-using networks for HIV testing, demonstrates higher positivity rates compared to other non-clinical recruitment strategies in some jurisdictions. During 2013-2015, a social networks testing protocol was implemented in Wisconsin to standardize an existing social networks testing program. Six community-based, non-clinical agencies with multiple sites throughout the state implemented the protocol over the 2-year period. Both quantitative and qualitative data were collected. The new positivity rate (0.49%) through social networks testing did not differ from that of traditional counseling, testing, and referral recruitment methods (0.48%). Although social networks testing did not yield a higher new positivity rate compared to other testing strategies, it proved to be successful at reaching high risk individuals who may not otherwise engage in HIV testing.

  11. A study of the rheological properties of endodontic sealers.

    PubMed

    Lacey, S; Pitt Ford, T R; Watson, T F; Sherriff, M

    2005-08-01

    To test the hypothesis that there would be no statistically significant difference in viscosity-related measures of endodontic sealers or change in these with strain rate, internal diameter or powder : liquid ratio in a capillary system. Materials used were Apexit, Tubliseal EWT, Grossman's sealer and Ketac-endo. Viscosity-related measures were tested in a two-plate test, and in a capillary rheometer. The mean values (n = 12) for thickness and diameter of material formed between two glass plates were tested with one-way analysis of variance. Pressure was applied to a capillary rheometer at strain rates 5 and 10 mm min(-1) in tubes of internal diameter 0.6 and 1.2 mm. Tubliseal EWT had a thinner film thickness than the other sealers (alpha = 0.05). The difference in diameter between Tubliseal EWT and the other sealers was significant apart from Apexit. Increased strain rate gave a significant increase (alpha = 0.05) in the flow of all sealers. Narrower tubes produced increased velocity, which was significant for all sealers, and reduced volumetric flow, which was significant for all sealers except Grossman's 2 : 1 (Wilcoxon signed rank test). Reduction in powder : liquid ratio of Grossman's significantly increased flow in narrow tubes and at higher strain rate (Mann-Whitney test). There was a significant difference between the flow of Tubliseal EWT and the other sealers tested in the two-plate test; capillary flow was affected by sealer, internal diameter, strain rate and powder : liquid ratio. The null hypotheses were rejected.

  12. Regression rate study of porous axial-injection, endburning hybrid fuel grains

    NASA Astrophysics Data System (ADS)

    Hitt, Matthew A.

    This experimental and theoretical work examines the effects of gaseous oxidizer flow rates and pressure on the regression rates of porous fuels for hybrid rocket applications. Testing was conducted using polyethylene as the porous fuel and both gaseous oxygen and nitrous oxide as the oxidizer. Nominal test articles were tested using 200, 100, 50, and 15 micron fuel pore sizes. Pressures tested ranged from atmospheric to 1160 kPa for the gaseous oxygen tests and from 207 kPa to 1054 kPa for the nitrous oxide tests, and oxidizer injection velocities ranged from 35 m/s to 80 m/s for the gaseous oxygen tests and from 7.5 m/s to 16.8 m/s for the nitrous oxide tests. Regression rates were determined using pretest and posttest length measurements of the solid fuel. Experimental results demonstrated that the regression rate of the porous axial-injection, end-burning hybrid was a function of the chamber pressure, as opposed to the oxidizer mass flux typical in conventional hybrids. Regression rates ranged from approximately 0.75 mm/s at atmospheric pressure to 8.89 mm/s at 1160 kPa for the gaseous oxygen tests and 0.21 mm/s at 207 kPa to 1.44 mm/s at 1054 kPa for the nitrous oxide tests. The analytical model was developed based on a standard ablative model modified to include oxidizer flow through the grain. The heat transfer from the flame was primarily modeled using an empirically determined flame coefficient that included all heat transfer mechanisms in one term. An exploratory flame model based on the Granular Diffusion Flame model used for solid rocket motors was also adapted for comparison with the empirical flame coefficient. This model was then evaluated quantitatively using the experimental results of the gaseous oxygen tests as well as qualitatively using the experimental results of the nitrous oxide tests. The model showed agreement with the experimental results indicating it has potential for giving insight into the flame structure in this motor configuration. Results from the model suggested that both kinetic and diffusion processes could be relevant to the combustion depending on the chamber pressure.

  13. Experimental and Numerical Study on Tensile Strength of Concrete under Different Strain Rates

    PubMed Central

    Min, Fanlu; Yao, Zhanhu; Jiang, Teng

    2014-01-01

    The dynamic characterization of concrete is fundamental to understand the material behavior in case of heavy earthquakes and dynamic events. The implementation of material constitutive law is of capital importance for the numerical simulation of the dynamic processes as those caused by earthquakes. Splitting tensile concrete specimens were tested at strain rates of 10−7 s−1 to 10−4 s−1 in an MTS material test machine. Results of tensile strength versus strain rate are presented and compared with compressive strength and existing models at similar strain rates. Dynamic increase factor versus strain rate curves for tensile strength were also evaluated and discussed. The same tensile data are compared with strength data using a thermodynamic model. Results of the tests show a significant strain rate sensitive behavior, exhibiting dynamic tensile strength increasing with strain rate. In the quasistatic strain rate regime, the existing models often underestimate the experimental results. The thermodynamic theory for the splitting tensile strength of concrete satisfactorily describes the experimental findings of strength as effect of strain rates. PMID:24883355

  14. Patterns of HIV and STI testing among MSM couples in the U.S.

    PubMed Central

    Mitchell, Jason W.; Petroll, Andrew E.

    2012-01-01

    Background Most MSM within the U.S. acquire HIV while in a same-sex relationship. Few studies have examined HIV and STI testing rates among MSM couples. Interestingly, the patterns that MSM test for HIV while in their relationships remain largely unknown. The present study helps fill this gap in knowledge by assessing HIV testing patterns and HIV and STI testing rates from a large convenience sample of Internet-using MSM couples. Methods : The present study used a cross-sectional study design to collect dyadic data from 361 MSM couples who lived throughout the US. A novel recruitment strategy that included placing paid, targeted advertisements on Facebook enrolled both men in the couple to independently complete the confidential, electronic survey. Results Nearly half of the HIV-negative men indicated either not having been tested for HIV since their relationship started or only testing if they felt they were at risk. Few men reported testing every 3-4 months. HIV/STI testing rates varied among the sample of couples. Few men reported having been diagnosed with a recent STI. Testing patterns and rates were mostly similar, irrespective of whether UAI was practiced within and/or outside the relationship. Conclusions HIV testing and prevention services must target men who are at risk for acquiring HIV within MSM couples. To help accomplish this goal, additional research is needed to examine the specific barriers and facilitators to HIV and STI testing among MSM in couples. PMID:23060078

  15. Field test comparison of two dermal tolerance assessment methods of hand hygiene products.

    PubMed

    Girard, R; Carré, E; Pires-Cronenberger, S; Bertin-Mandy, M; Favier-Bulit, M C; Coyault, C; Coudrais, S; Billard, M; Regard, A; Kerhoas, A; Valdeyron, M L; Cracco, B; Misslin, P

    2008-06-01

    This study aimed to compare the sensitivity and workload requirement of two dermal tolerance assessment methods of hand hygiene products, in order to select a suitable pilot testing method for field tests. An observer-rating method and a self-assessment method were compared in 12 voluntary hospital departments (autumn/winter of 2005-2006). Three test-periods of three weeks were separated by two-week intervals during which the routine products were reintroduced. The observer rating method scored dryness and irritation on four-point scales. In the self-assessment method, the user rated appearance, intactness, moisture content, and sensation on a visual analogue scale which was converted into a 10-point numerical scale. Eleven products (soaps) were tested (223/250 complete reports for observer rating, 131/251 for self-assessment). Two products were significantly less well tolerated than the routine product according to the observers, four products according to the self-assessments. There was no significant difference between the two methods when products were classified according to tolerance (Fisher's test: P=0.491). For the symptom common to both assessment methods (dryness), there is a good correlation between the two methods (Spearman's Rho: P=0.032). The workload was higher for observer rating method (288 h of observer time plus 122 h of prevention team and pharmacist time compared with 15 h of prevention team and pharmacist time for self-assessment). In conclusion, the self-assessment method was considered more suitable for pilot testing, although further time should be allocated for educational measures as the return rate of complete self-assessment forms was poor.

  16. Respiratory muscle strength test: is it realistic in young children?

    PubMed Central

    Heinzmann-Filho, João Paulo; Donadio, Márcio Vinícius Fagundes

    2015-01-01

    Objective: To determine the success rate of the manovacuometry test in children between 4 and 12 years of age. Methods: Cross-sectional study involving children and adolescents from 4 to 12 years of age, enrolled in three basic education schools. All subjects had the anthropometric and respiratory muscle strength (maximum inspiratory pressure and maximum expiratory pressure) data measured. Students whose parents did not authorize participation or who did not want to undergo the test were excluded. The test was considered successful when the subject reached acceptability (no air leaks) and reproducibility (variation <10% between the two major maneuvers) criteria established by guidelines. Failure was defined when subjects did not meet the above criteria. Data were expressed as mean and standard deviation and the categorical variables in absolute and relative frequency. The comparison between proportions was performed using the chi-square test. Results: We included 196 children and adolescents, mean age of 8.4±2.5 years, 53.1% female. The success rate of the manovacuometry test in children and adolescents evaluated was 92.3%. When comparing the differences between the success rates of preschool children with those children and adolescents of school age, there was a significantly lower success rate in the pre-school (85.1%) group compared to the school group (94.6%) (p=0.032). However, no significant differences (p=0.575) were found when gender comparisons were performed. Conclusions: The manovacuometry test showed a high success rate in both preschool and school population assessed. Furthermore, the rate of success appears to be related to aging. PMID:26137867

  17. Long-term ongoing pregnancy rate and mode of conception after a positive and negative post-coital test.

    PubMed

    Hessel, Marloes; Brandes, Monique; de Bruin, Jan Peter; Bots, Rob S G M; Kremer, Jan A M; Nelen, Willianne L D M; Hamilton, Carl J C M

    2014-09-01

    Many fertility clinics have decided to abolish the post-coital test. Yet, it is a significant factor in prognostic models that predict the spontaneous pregnancy rate within one year. The aim of this study was to evaluate (1) the long-term outcome of infertile couples with a positive or a negative post-coital test during their fertility work-up and (2) the contribution of the different modes of conception. Retrospective cohort study. Three fertility clinics in the Netherlands, of which two are secondary care training hospitals and is a one tertiary care academic training hospital. 2476 newly referred infertile couples, where a post-coital test was performed in 1624 couples. After basic fertility work-up, couples were treated according to the national treatment protocols. Spontaneous and overall ongoing pregnancy rate. The spontaneous and overall ongoing pregnancy rates after three years were 37.7 and 77.5% after a positive post-coital test compared with 26.9 and 68.8% after a negative test (p < 0.001). Even in couples with severe male factor infertility (total motile sperm count <3) (p = 0.005) and mild male factor infertility (total motile sperm count 3-20) (p < 0.001), there was a significantly higher spontaneous ongoing pregnancy rate, justifying expectant management. After a follow-up of three years a positive post-coital test is still associated with a higher spontaneous and a higher overall ongoing pregnancy rate, even in couples with severe male factor infertility. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.

  18. The Impact of an Electronic Expensive Test Notification.

    PubMed

    Riley, Jacquelyn D; Stanley, Glenn; Wyllie, Robert; Kottke-Marchant, Kandice; Procop, Gary W

    2018-04-25

    The impact of clinical decision support tools (CDSTs) that display test cost information has been variable. We retrospectively analyzed the 3-year impact of a passive CDST that notified providers when the test order cost was $1,000 or more. We determined the most common expensive tests ordered, the frequency with which providers abandoned the order after notification, and the costs saved through this intervention. The average monthly abandonment rate was 12.5% (2014), 12.9% (2015), and 14.3% (2016). The cost savings from tests not performed for this 3-year period was $696,007. Molecular hematopathology assays were the most frequently ordered tests, with variable abandonment rates. Although this CDST was passive (ie, could be overridden at the point of order entry) and was associated with a relatively low abandonment rate, it achieved a considerable cost savings each year since each abandoned test saved the institution $1,000 or more.

  19. The rate of epinephrine administration associated with allergy skin testing in a suburban allergy practice from 1997 to 2010.

    PubMed

    Swender, David A; Chernin, Leah R; Mitchell, Chris; Sher, Theodore; Hostoffer, Robert; Tcheurekdjian, Haig

    2012-01-01

    Allergy skin testing is considered a safe method for testing for IgE-mediated allergic responses although anaphylactic events can occur. Reported rates of anaphylaxis per patient are not consistent and range from 0.008 to 4%. The aim of this study was to determine the rate of epinephrine use associated with allergy skin-prick testing (SPT) and intradermal testing (IDT) in a suburban practice over 13 years. This retrospective chart review used billing and procedure coding records during the time period from January 1997 to June 2010 to identify encounters where epinephrine was administered after SPT or IDT. Patient encounters with procedure codes for skin testing plus either parenteral epinephrine, corticosteroid, antihistamine, or i.v. fluid administration were identified. These patient charts were reviewed to determine if epinephrine was administered, whether systemic reactions developed, and rates of epinephrine administration were calculated. There were 28,907 patient encounters for SPT and 18,212 for IDT. Epinephrine was administered in six patient encounters (0.02%) where SPT was performed; no IDT encounters led to epinephrine administration. There were no fatalities. Allergy skin testing to a variety of allergens, when administered by well-trained personnel, is a safe procedure. This study, involving the largest population to date, showed a rate of systemic reactions requiring epinephrine of 20 per 100,000 SPT visits. No epinephrine was given after IDT.

  20. The rate of epinephrine administration associated with allergy skin testing in a suburban allergy practice from 1997 to 2010

    PubMed Central

    Chernin, Leah R.; Mitchell, Chris; Sher, Theodore; Hostoffer, Robert; Tcheurekdjian, Haig

    2012-01-01

    Allergy skin testing is considered a safe method for testing for IgE-mediated allergic responses although anaphylactic events can occur. Reported rates of anaphylaxis per patient are not consistent and range from 0.008 to 4%. The aim of this study was to determine the rate of epinephrine use associated with allergy skin-prick testing (SPT) and intradermal testing (IDT) in a suburban practice over 13 years. This retrospective chart review used billing and procedure coding records during the time period from January 1997 to June 2010 to identify encounters where epinephrine was administered after SPT or IDT. Patient encounters with procedure codes for skin testing plus either parenteral epinephrine, corticosteroid, antihistamine, or i.v. fluid administration were identified. These patient charts were reviewed to determine if epinephrine was administered, whether systemic reactions developed, and rates of epinephrine administration were calculated. There were 28,907 patient encounters for SPT and 18,212 for IDT. Epinephrine was administered in six patient encounters (0.02%) where SPT was performed; no IDT encounters led to epinephrine administration. There were no fatalities. Allergy skin testing to a variety of allergens, when administered by well-trained personnel, is a safe procedure. This study, involving the largest population to date, showed a rate of systemic reactions requiring epinephrine of 20 per 100,000 SPT visits. No epinephrine was given after IDT. PMID:23342290

  1. Promoted Combustion Test Propagation Rate Data

    NASA Technical Reports Server (NTRS)

    Borstorff, J.; Jones, P.; Lowery, F.

    2002-01-01

    Combustion propagation rate data were examined for potential use in benchmarking a thermal model of the Promoted Combustion Test (PCT), and also for potential use in measuring the repeatability of PCT results.

  2. HIV testing among male partners of pregnant women in Nigeria: a missing link in the elimination of mother-to-child transmission of HIV.

    PubMed

    Olakunde, Babayemi O; Adeyinka, Daniel A; Oladele, Tolulope; Ozigbu, Chamberline E

    2018-03-01

    In this study, we assessed male partner testing and the serodiscordance rate among pregnant women and their partners in the prevention of mother-to-child transmission (PMTCT) programme in Nigeria. We conducted a retrospective analysis of the consolidated national health sector PMTCT data over a five-year period (2012-2016). Over the period, a total of 11,833,062 pregnant women were tested for HIV with a positivity rate of 2.2%. About 266,188 (2.2%) of sexual partners of pregnant women who presented at PMTCT clinics had an HIV test within the period. The uptake of male partner testing varied across the years, ranging from 22,269 (1.7%) in 2012 to 90,603 (2.9%) in 2014 (χ 2 for trend = 1320; p < 0.001). Overall, the proportion of partners of HIV-negative pregnant women who tested was higher than the proportion of partners of HIV-positive pregnant women (81% versus 19%, respectively). The serodiscordance rate among partners who tested over the five-year period was 18%. The serodiscordance rate declined from 24% in 2012 to 13% in 2016 (χ 2 for trend = 1202; p < 0.001). Partner testing in the PMTCT programme in Nigeria has remained low in the last five years while the clinic-based serodiscordance rate among partners appears to be declining. There is a need for multilevel interventions to address the possible barriers to partner testing in the PMTCT programme and intensification of the HIV combination prevention approach in the HIV response.

  3. Identification of differentially expressed genes and false discovery rate in microarray studies.

    PubMed

    Gusnanto, Arief; Calza, Stefano; Pawitan, Yudi

    2007-04-01

    To highlight the development in microarray data analysis for the identification of differentially expressed genes, particularly via control of false discovery rate. The emergence of high-throughput technology such as microarrays raises two fundamental statistical issues: multiplicity and sensitivity. We focus on the biological problem of identifying differentially expressed genes. First, multiplicity arises due to testing tens of thousands of hypotheses, rendering the standard P value meaningless. Second, known optimal single-test procedures such as the t-test perform poorly in the context of highly multiple tests. The standard approach of dealing with multiplicity is too conservative in the microarray context. The false discovery rate concept is fast becoming the key statistical assessment tool replacing the P value. We review the false discovery rate approach and argue that it is more sensible for microarray data. We also discuss some methods to take into account additional information from the microarrays to improve the false discovery rate. There is growing consensus on how to analyse microarray data using the false discovery rate framework in place of the classical P value. Further research is needed on the preprocessing of the raw data, such as the normalization step and filtering, and on finding the most sensitive test procedure.

  4. The Evaluation of Olfactory Function in Patients With Schizophrenia.

    PubMed

    Robabeh, Soleimani; Mohammad, Jalali Mir; Reza, Ahmadi; Mahan, Badri

    2015-04-23

    The aim of this study was to compare olfactory threshold, smell identification, intensity and pleasantness ratings between patients with schizophrenia and healthy controls, and (2) to evaluate correlations between ratings of olfactory probes and illness characteristics. Thirty one patients with schizophrenia and 31 control subjects were assessed with the olfactory n-butanol threshold test, the Iran smell identification test (Ir-SIT), and the suprathreshold amyl acetate odor intensity and odor pleasantness rating test. All olfactory tasks were performed unirhinally. Patients with schizophrenia showed disrupted olfaction in all four measures. Longer duration of schizophrenia was associated with a larger impairment of olfactory threshold or microsmic range on the Ir-SIT (P=0.04, P=0.05, respectively). In patients with schizophrenia, female subjects' ratings of pleasantness followed the same trend as control subjects, whereas male patients' ratings showed an opposite trend. Patients exhibiting high positive score on the positive and negative syndrome scale (PANSS) performed better on the olfactory threshold test (r=0.37, P=0.04). The higher odor pleasantness ratings of patients were associated with presence of positive symptoms. The results suggest that both male and female patients with schizophrenia had difficulties on the olfactory threshold and smell identification tests, but appraisal of odor pleasantness was more disrupted in male patients.

  5. Fatigue crack growth in 7475-T651 aluminum alloy plate in hard vacuum and water vapor. M.S. Thesis - George Washington Univ.

    NASA Technical Reports Server (NTRS)

    Dicus, D. L.

    1981-01-01

    Compact specimens of 25 mm thick aluminum alloy plate were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Crack growth rates were determined at frequencies of 1 Hz and 10 Hz in hard vacuum and laboratory air, and in mixtures of water vapor and nitrogen at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. A significant effect of water vapor on fatigue crack growth rates was observed at the lowest water vapor pressure tested. Crack rates changed little for pressures up to 1.03 kPa, but abruptly accelerated at higher pressures. At low stress intensity factor ranges, cracking rates at the lowest and highest water vapor pressure tested were, respectively, two and five times higher than rates in vacuum. Although a frequency was observed in laboratory air, cracking rates in water vapor and vacuum are insensitive to a ten-fold change in frequency. Surfaces of specimens tested in water vapor and vacuum exhibited different amounts of residual deformation. Reduced deformation on the fracture surfaces of the specimens tested in water vapor suggests embrittlement of the plastic zone ahead of the crack tip as a result of environmental interaction.

  6. Sinusoidal high-intensity exercise does not elicit ventilatory limitation in chronic obstructive pulmonary disease.

    PubMed

    Porszasz, Janos; Rambod, Mehdi; van der Vaart, Hester; Rossiter, Harry B; Ma, Shuyi; Kiledjian, Rafi; Casaburi, Richard

    2013-06-01

    During exercise at critical power (CP) in chronic obstructive pulmonary disease (COPD) patients, ventilation approaches its maximum. As a result of the slow ventilatory dynamics in COPD, ventilatory limitation during supramaximal exercise might be escaped using rapid sinusoidal forcing. Nine COPD patients [age, 60.2 ± 6.9 years; forced expiratory volume in the first second (FEV(1)), 42 ± 17% of predicted; and FEV(1)/FVC, 39 ± 12%] underwent an incremental cycle ergometer test and then four constant work rate cycle ergometer tests; tolerable duration (t(lim)) was recorded. Critical power was determined from constant work rate testing by linear regression of work rate versus 1/t(lim). Patients then completed fast (FS; 60 s period) and slow (SS; 360 s period) sinusoidally fluctuating exercise tests with mean work rate at CP and peak at 120% of peak incremental test work rate, and one additional test at CP; each for a 20 min target. The value of t(lim) did not differ between CP (19.8 ± 0.6 min) and FS (19.0 ± 2.5 min), but was shorter in SS (13.2 ± 4.2 min; P < 0.05). The sinusoidal ventilatory amplitude was minimal (37.4 ± 34.9 ml min(-1) W(-1)) during FS but much larger during SS (189.6 ± 120.4 ml min(-1) W(-1)). The total ventilatory response in SS reached 110 ± 8.0% of the incremental test peak, suggesting ventilatory limitation. Slow components in ventilation during constant work rate and FS exercises were detected in most subjects and contributed appreciably to the total response asymptote. The SS exercise was associated with higher mid-exercise lactate concentrations (5.2 ± 1.7, 7.6 ± 1.7 and 4.5 ± 1.3 mmol l(-1) in FS, SS and CP). Large-amplitude, rapid sinusoidal fluctuation in work rate yields little fluctuation in ventilation despite reaching 120% of the incremental test peak work rate. This high-intensity exercise strategy might be suitable for programmes of rehabilitative exercise training in COPD.

  7. O-Ring-Testing Fixture

    NASA Technical Reports Server (NTRS)

    Turner, James E.; Mccluney, D. Scott

    1991-01-01

    Fixture tests O-rings for sealing ability under dynamic conditions after extended periods of compression. Hydraulic cylinder moves plug in housing. Taper of 15 degrees on plug and cavity of housing ensures that gap created between O-ring under test and wall of cavity. Secondary O-rings above and below test ring maintain pressure applied to test ring. Evaluates effects of variety of parameters, including temperature, pressure, rate of pressurization, rate and magnitude of radial gap movement, and pretest compression time.

  8. Language of administration and neuropsychological test performance in neurologically intact Hispanic American bilingual adults.

    PubMed

    Gasquoine, Philip Gerard; Croyle, Kristin L; Cavazos-Gonzalez, Cynthia; Sandoval, Omar

    2007-11-01

    This study compared the performance of Hispanic American bilingual adults on Spanish and English language versions of a neuropsychological test battery. Language achievement test scores were used to divide 36 bilingual, neurologically intact, Hispanic Americans from south Texas into Spanish-dominant, balanced, and English-dominant bilingual groups. They were administered the eight subtests of the Bateria Neuropsicologica and the Matrix Reasoning subtest of the WAIS-III in Spanish and English. Half the participants were tested in Spanish first. Balanced bilinguals showed no significant differences in test scores between Spanish and English language administrations. Spanish and/or English dominant bilinguals showed significant effects of language of administration on tests with higher language compared to visual perceptual weighting (Woodcock-Munoz Language Survey-Revised, Letter Fluency, Story Memory, and Stroop Color and Word Test). Scores on tests with higher visual-perceptual weighting (Matrix Reasoning, Figure Memory, Wisconsin Card Sorting Test, and Spatial Span), were not significantly affected by language of administration, nor were scores on the Spanish/California Verbal Learning Test, and Digit Span. A problem was encountered in comparing false positive rates in each language, as Spanish norms fell below English norms, resulting in a much higher false positive rate in English across all bilingual groupings. Use of a comparison standard (picture vocabulary score) reduced false positive rates in both languages, but the higher false positive rate in English persisted.

  9. Method of Testing Oxygen Regulators

    NASA Technical Reports Server (NTRS)

    Sontag, Harcourt; Borlik, E L

    1935-01-01

    Oxygen regulators are used in aircraft to regulate automatically the flow of oxygen to the pilot from a cylinder at pressures ranging up to 150 atmospheres. The instruments are adjusted to open at an altitude of about 15,000 ft. and thereafter to deliver oxygen at a rate which increases with the altitude. The instruments are tested to determine the rate of flow of oxygen delivered at various altitudes and to detect any mechanical defects which may exist. A method of testing oxygen regulators was desired in which the rate of flow could be determined more accurately than by the test method previously used (reference 1) and by which instruments defective mechanically could be detected. The new method of test fulfills these requirements.

  10. Parental versus non-parental-directed donation: an 11-year experience of infectious disease testing at a pediatric tertiary care blood donor center.

    PubMed

    Jacquot, Cyril; Seo, Andrew; Miller, Peter M; Lezama, Niara; Criss, Valli R; Colvin, Camilla; Luban, Naomi L C; Wong, Edward C C

    2017-11-01

    Directed donation is associated with a higher prevalence of donations that are positive for infectious disease markers; however, little is known about the positive rates among parental-directed, non-parental-directed, and allogeneic donations. We reviewed blood-collection records from January 1997 through December 2008, including infectious disease results, among parental, non-parental, and community donations. Infectious disease rates were compared by Mann-Whitney U test. In total, 1532 parental, 4910 non-parental, and 17,423 community donations were examined. Among parental donors, the median rate of positive infectious disease testing was 8.66% (interquartile range (IQR), 4.49%) for first-time donors and 1.26% (IQR, 5.86%) for repeat donors; among non-parental donors, the rate was 1.09% (IQR, 0.98%) for first-time donors and 0% (IQR, 0.83%) for repeat donors; and, among community donors, the rate was 2.95% (IQR, 1.50%) for first-time donors and 0.45% (IQR, 0.82%) for repeat donors. The mean rate of positive infectious disease testing for first-time parental donors was significantly higher (7.63%), whereas all repeat donors had similar rates. However, the rate of positive infectious disease testing among first-time non-parental donors was significantly lower than that in the other groups, especially for the period from 2001 through 2008. First-time non-parental and community donors had significantly higher infectious disease risk than the respective repeat donors. First-time parental donors had the highest rates of positive infectious disease testing. We suggest that first-time parental blood donation should be discouraged. Repeat community donors or first-time non-parental donors provide a safer alternative. These findings can foster better patient education, donor selection, and possibly a reduced risk of infectious disease. © 2017 AABB.

  11. Do gifts increase consent to home-based HIV testing? A difference-in-differences study in rural KwaZulu-Natal, South Africa.

    PubMed

    McGovern, Mark E; Herbst, Kobus; Tanser, Frank; Mutevedzi, Tinofa; Canning, David; Gareta, Dickman; Pillay, Deenan; Bärnighausen, Till

    2016-12-01

    Despite the importance of HIV testing for controlling the HIV epidemic, testing rates remain low. Efforts to scale up testing coverage and frequency in hard-to-reach and at-risk populations commonly focus on home-based HIV testing. This study evaluates the effect of a gift (a US$5 food voucher for families) on consent rates for home-based HIV testing. We use data on 18 478 individuals (6 418 men and 12 060 women) who were successfully contacted to participate in the 2009 and 2010 population-based HIV surveillance carried out by the Wellcome Trust's Africa Health Research Institute in rural KwaZulu-Natal, South Africa. Of 18 478 potential participants contacted in both years, 35% (6 518) consented to test in 2009, and 41% (7 533) consented to test in 2010. Our quasi-experimental difference-in-differences approach controls for unobserved confounding in estimating the causal effect of the intervention on HIV-testing consent rates. Allocation of the gift to a family in 2010 increased the probability of family members consenting to test in the same year by 25 percentage points [95% confidence interval (CI) 21-30 percentage points; P  < 0.001]. The intervention effect persisted, slightly attenuated, in the year following the intervention (2011). In HIV hyperendemic settings, a gift can be highly effective at increasing consent rates for home-based HIV testing. Given the importance of HIV testing for treatment uptake and individual health, as well as for HIV treatment-as-prevention strategies and for monitoring the population impact of the HIV response, gifts should be considered as a supportive intervention for HIV-testing initiatives where consent rates have been low. © The Author 2016. Published by Oxford University Press on behalf of the International Epidemiological Association

  12. Assessing the Medication Adherence App Marketplace From the Health Professional and Consumer Vantage Points

    PubMed Central

    2017-01-01

    Background Nonadherence produces considerable health consequences and economic burden to patients and payers. One approach to improve medication nonadherence that has gained interest in recent years is the use of smartphone adherence apps. The development of smartphone adherence apps has increased rapidly since 2012; however, literature evaluating the clinical app and effectiveness of smartphone adherence apps to improve medication adherence is generally lacking. Objective The aims of this study were to (1) provide an updated evaluation and comparison of medication adherence apps in the marketplace by assessing the features, functionality, and health literacy (HL) of the highest-ranking adherence apps and (2) indirectly measure the validity of our rating methodology by determining the relationship between our app evaluations and Web-based consumer ratings. Methods Two independent reviewers assessed the features and functionality using a 4-domain rating tool of all adherence apps identified based on developer claims. The same reviewers downloaded and tested the 100 highest-ranking apps including an additional domain for assessment of HL. Pearson product correlations were estimated between the consumer ratings and our domain and total scores. Results A total of 824 adherence apps were identified; of these, 645 unique apps were evaluated after applying exclusion criteria. The median initial score based on descriptions was 14 (max of 68; range 0-60). As a result, 100 of the highest-scoring unique apps underwent user testing. The median overall user-tested score was 31.5 (max of 73; range 0-60). The majority of the user tested the adherence apps that underwent user testing reported a consumer rating score in their respective online marketplace. The mean consumer rating was 3.93 (SD 0.84). The total user-tested score was positively correlated with consumer ratings (r=.1969, P=.04). Conclusions More adherence apps are available in the Web-based marketplace, and the quality of these apps varies considerably. Consumer ratings are positively but weakly correlated with user-testing scores suggesting that our rating tool has some validity but that consumers and clinicians may assess adherence app quality differently. PMID:28428169

  13. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    PubMed

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. The Effects of a Normal Rate versus a Slow Intervalled Rate of Oral Nutrient Intake and Intravenous Low Rate Macronutrient Application on Psychophysical Function - Two Pilot Studies.

    PubMed

    Denzer-Lippmann, Melanie Y; Bachlechner, Stephan; Wielopolski, Jan; Fischer, Marie; Buettner, Andrea; Doerfler, Arndt; Schöfl, Christof; Münch, Gerald; Kornhuber, Johannes; Thürauf, Norbert

    2017-01-01

    Stomach distension and energy per time are factors influencing satiety. Moreover, different rates of nutrient intake induce different stomach distension. The goal of our studies was to elucidate the influence of different oral rates of nutrient intake (normal rate versus slow intervalled rate; study I) and intravenous low rate macronutrient application (protein, carbohydrate, fat) or placebo (study II) on psychophysical function. The pilot studies investigated the effects of 1) study I: a mixed nutrient solution (1/3 protein, 1/3 fat, 1/3 carbohydrates) 2) study II: intravenous macronutrient infusions (protein, carbohydrate, fat) or placebo on psychophysical function (mood, hunger, food craving, alertness, smell intensity ratings and hedonic ratings) in human subjects. In study I 10 male subjects (age range: 21-30 years) completed the study protocol participating in both test conditions and in study II 20 male subjects (age range: 19-41 years) completed the study protocol participating in all test conditions. Additionally, metabolic function was analyzed and cognitive and olfactory tests were conducted twice starting 100 min before the beginning of the intervention and 240 min after. Psychophysical (mood, hunger, fat-, protein-, carbohydrate-, sweets- and vegetable-craving), alertness and metabolic function tests were performed seven times on each examination day. Greater effects on hunger and food cravings were observed for normal rate of intake compared to slow intervalled rate of intake and intravenous low rate macronutrient application. Our findings potentially confirm that volume of the food ingested and a higher rate of energy per time contribute to satiety during normal rate of food intake, while slow intervalled rate of food intake and intravenous low rate macronutrient application showed no effects on satiation. Our results motivate the view that a certain amount of volume of the food ingested and a certain energy per time ratio are necessary to reduce hunger and food craving.

  15. The effect of branding on consumer palatability ratings of beef strip loin steaks.

    PubMed

    Wilfong, A K; McKillip, K V; Gonzalez, J M; Houser, T A; Unruh, J A; Boyle, E A E; O'Quinn, T G

    2016-11-01

    The objective of this study was to determine the influence of knowing the brand or USDA grade on consumer palatability ratings of beef strip loin steaks. Strip loins were selected to represent 5 USDA grades and brands, USDA Select, Choice, Prime, Certified Angus Beef (CAB; upper 2/3 Choice), and Select, from carcasses of cattle classified as Angus on the basis of phenotype. After 21 d of aging, 2.5-cm-thick steaks were cut, consecutively cut steaks were paired for consumer evaluation. Consumer panelists ( = 112) evaluated samples for tenderness, juiciness, flavor liking, and overall liking. Additionally, consumers rated each palatability trait as either acceptable or unacceptable. Samples were fed in 2 rounds on the same day: blind and informed testing. In the first round, blind testing, consumers were served 1 sample from each treatment, with no product information provided. In the second round, consumers were informed of the brand or quality grade prior to sampling. During blind testing, CAB rated similar ( > 0.05) to Choice for all palatability traits; however, CAB rated greater ( < 0.05) than Choice for all traits during informed testing. Additionally, Angus Select and Select were rated similar > 0.05) for all traits when tested blind, but Angus Select was rated greater ( < 0.05) than Select for flavor and overall liking when brand was declared. When comparing blind and informed ratings, Angus Select and CAB had greater ( < 0.05) ratings for juiciness, flavor liking, and overall liking, and Prime had increased ( < 0.05) ratings for flavor liking and overall liking because of brand disclosure. However, ratings for Choice and Select samples were unaffected ( > 0.05) when brand was disclosed. Brand knowledge increased ( < 0.05) the percentage of Prime samples rated as acceptable for flavor and the percentage of Angus Select samples rated as acceptable for flavor and overall liking. Conversely, there was no difference ( > 0.05) in the percentage of Choice and Select samples rated as acceptable for all palatability traits. These data indicate that Prime, CAB, and Angus Select steaks receive an increase in consumer palatability perception, or "brand lift," which does not occur for Choice and Select beef.

  16. Clinical decision making in response to performance validity test failure in a psychiatric setting.

    PubMed

    Marcopulos, Bernice A; Caillouet, Beth A; Bailey, Christopher M; Tussey, Chriscelyn; Kent, Julie-Ann; Frederick, Richard

    2014-01-01

    This study examined the clinical utility of a performance validity test (PVT) for screening consecutive referrals (N = 436) to a neuropsychology service at a state psychiatric hospital treating both civilly committed and forensic patients. We created a contingency table with Test of Memory Malingering (TOMM) pass/fail (355/81) and secondary gain present/absent (181/255) to examine pass rates associated with patient demographic, clinical and forensic status characteristics. Of the 81 failed PVTs, 48 had secondary gain defined as active criminal legal charges; 33 failed PVTs with no secondary gain. These individuals tended to be older, female, Caucasian, and civilly committed compared with the group with secondary gain who failed. From estimations of TOMM False Positive Rate and True Positive Rate we estimated base rates of neurocognitive malingering for our clinical population using the Test Validation Summary (TVS; Frederick & Bowden, 2009 ). Although PVT failure is clearly more common in a group with secondary gain (31%), there were a number of false positives (11%). Clinical ratings of patients without gain who failed suggested cognitive deficits, behavioral issues, and inattention. Low scores on PVTs in the absence of secondary gain provide useful information on test engagement and can inform clinical decisions about testing.

  17. Bit-error-rate testing of fiber optic data links for MMIC-based phased array antennas

    NASA Technical Reports Server (NTRS)

    Shalkhauser, K. A.; Kunath, R. R.; Daryoush, A. S.

    1990-01-01

    The measured bit-error-rate (BER) performance of a fiber optic data link to be used in satellite communications systems is presented and discussed. In the testing, the link was measured for its ability to carry high burst rate, serial-minimum shift keyed (SMSK) digital data similar to those used in actual space communications systems. The fiber optic data link, as part of a dual-segment injection-locked RF fiber optic link system, offers a means to distribute these signals to the many radiating elements of a phased array antenna. Test procedures, experimental arrangements, and test results are presented.

  18. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    PubMed

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  19. The relationship between change in subjective outcome and change in disease: a potential paradox.

    PubMed

    Kievit, Wietske; Hendrikx, Jos; Stalmeier, Peep F M; van de Laar, Mart A F J; Van Riel, Piet L C M; Adang, Eddy M

    2010-09-01

    Response shift theory suggests that improvements in health lead patients to change their internal standards and re-assess former health states as worse than initially rated when using retrospective ratings via the then-test. The predictions of response shift theory can be illustrated using prospect theory, whereby a change in current health causes a change in reference frame. Therefore, if health deteriorates, the former health state will receive a better rating, whereas if it improves, the former health state will receive a worse rating. To explore the predictions of response shift and prospect theory by relating subjective change to objective change. Baseline and 3-month follow-up data from a cohort of rheumatoid arthritis patients (N = 197) starting on TNFalpha-blocking agents were used. Objective disease change was classified according to a disease-specific clinical outcome measure (DAS28). Visual analogue scales (VAS) for general health (GH) and pain were used as self-reported measures. Three months after starting on anti-TNFalpha, patients used the then-test to re-rate their baseline health with regard to general health and pain. Differences between then-test value and baseline values were calculated and tested between improved, non-improved and deteriorated patients by the Student t-test. At 3 months, 51 (25.9%) patients had good improvement in health, 83 (42.1%) had moderate improvement, and 63 (32.0%) had no improvement or deteriorated in health. All patients no matter whether they improved, did not improve, or even became worse rated their health as worse retrospectively. The difference between the then-test rating and the baseline value was similarly sized in all groups. More positive ratings of retrospective health are independent of disease change. This suggests that patients do not necessarily change their standards in line with their disease change, and therefore it is inappropriate to use the then-test to correct for such a change. If a then-test is used to correct for shifts in internal standards, it might lead to the paradoxical result that patients who do not improve or even deteriorate increase significantly on self-reported health and pain. An alternative explanation for differences in retrospective and prospective ratings of health is the implicit theory of change which is more successful in explaining our results than prospect theory.

  20. TVT-O vs. TVT for the treatment of SUI: a non-inferiority study.

    PubMed

    Yang, Xiang; Jiang, Min; Chen, Xinliang; Tong, Xiaowen; Li, Huaifang; Qiu, Jin; Shao, Lingyun

    2012-01-01

    This study aimed to prospectively compare, in terms of efficacy and safety, the tension-free vaginal tape (TVT) and the transobturator vaginal tape inside-out (TVT-O) procedure for stress urinary incontinence. A cough stress test was applied to the objective outcomes, while urinary incontinence-specific quality of life questionnaire was applied to the subjective outcomes. A test for non-inferiority was carried out for detecting the success rate between the two groups. The objective success rates were found to be 95.4% (62/65) in the TVT group and 96.4% (108/112) in the TVT-O group. No significant difference was found between these two groups in the success rate by non-inferiority test (P < 0.0005), with significant improvement in quality of life and no significant difference in patient satisfaction rates in the two groups (P > 0.05). In the study, the TVT-O procedure could be defined to be identical to the TVT approach in success rate by non-inferiority test.

  1. Effect of Load Rate on Ultimate Tensile Strength of Ceramic Matrix Composites at Elevated Temperatures

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    2001-01-01

    The strengths of three continuous fiber-reinforced ceramic composites, including SiC/CAS-II, SiC/MAS-5 and SiC/SiC, were determined as a function of test rate in air at 1100 to 1200 C. All three composite materials exhibited a strong dependency of strength on test rate, similar to the behavior observed in many advanced monolithic ceramics at elevated temperatures. The application of the preloading technique as well as the prediction of life from one loading configuration (constant stress-rate) to another (constant stress loading) suggested that the overall macroscopic failure mechanism of the composites would be the one governed by a power-law type of damage evolution/accumulation, analogous to slow crack growth commonly observed in advanced monolithic ceramics. It was further found that constant stress-rate testing could be used as an alternative to life prediction test methodology even for composite materials, at least for short range of lifetimes and when ultimate strength is used as the failure criterion.

  2. Silicon Isotopes doping experiments to measure quartz dissolution and precipitation rates at equilibrium and test the principle of detailed balance

    NASA Astrophysics Data System (ADS)

    Zhu, C.; Rimstidt, J. D.; Liu, Z.; Yuan, H.

    2016-12-01

    The principle of detailed balance (PDB) has been a cornerstone for irreversible thermodynamics and chemical kinetics for a long time, and its wide application in geochemistry has mostly been implicit and without experimental testing of its applicability. Nevertheless, many extrapolations based on PDB without experimental validation have far reaching impacts on society's mega environmental enterprises. Here we report an isotope doping method that independently measures simultaneous dissolution and precipitation rates and can test this principle. The technique reacts a solution enriched in a rare isotope of an element with a solid having natural isotopic abundances (Beck et al., 1992; Gaillardet, 2008; Gruber et al., 2013). Dissolution and precipitation rates are found from the changing isotopic ratios. Our quartz experiment doped with 29Si showed that the equilibrium dissolution rate remains unchanged at all degrees of undersaturation. We recommend this approach to test the validity of using the detailed balance relationship in rate equations for other substances.

  3. Ultimate Tensile Strength as a Function of Test Rate for Various Ceramic Matrix Composites at Elevated Temperatures

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Bansal, Narottam P.; Gyekenyesi, John P.

    2002-01-01

    Ultimate tensile strength of five different continuous fiber-reinforced ceramic composites, including SiC/BSAS (2D 2 types), SiC/MAS-5 (2D), SiC/SiC (2D enhanced), and C/SiC(2D) was determined as a function of test rate at I 100 to 1200 'C in air. All five composite materials exhibited a significant dependency of ultimate strength on test rate such that the ultimate strength decreased with decreasing test rate, similar to the behavior observed in many advanced monolithic ceramics at elevated temperatures. The application of the preloading technique as well as the prediction of life from one loading configuration (constant stress rate) to another (constant stress loading) for SiC/BSAS suggested that the overall macroscopic failure mechanism of the composites would be the one governed by a power-law type of damage evolution/accumulation, analogous to slow crack growth commonly observed in advanced monolithic ceramics.

  4. Leak rate measurements for satellite subsystems and residual gas analysis during space environment tests. [thermal vacuum and solar simulation tests

    NASA Technical Reports Server (NTRS)

    Nuss, H. E.

    1975-01-01

    The measuring and evaluation procedure for the determination of leak rates of satellite subsystems with a quadrupole mass spectrometer, and the results of the residual gas analysis are described. The method selected for leak rate determination was placing the system into a vacuum chamber and furnishing the chamber with a mass spectrometer and calibrated leaks. The residual gas of a thermal vacuum test facility, in which the thermal balance test radiation input was simulated by a heated canister, was analyzed with the mass spectrometer in the atomic mass unit range up to 300 amu. In addition to the measurements during the space environment tests, mass spectrometric studies were performed with samples of spacecraft materials. The studies were carried out during tests for the projects HELIOS, AEROS B and SYMPHONIE.

  5. Relative User Ratings of MMPI-2 Computer-Based Test Interpretations

    ERIC Educational Resources Information Center

    Williams, John E.; Weed, Nathan C.

    2004-01-01

    There are eight commercially available computer-based test interpretations (CBTIs) for the Minnesota Multiphasic Personality Inventory-2 (MMPI-2), of which few have been empirically evaluated. Prospective users of these programs have little scientific data to guide choice of a program. This study compared ratings of these eight CBTIs. Test users…

  6. 49 CFR 173.319 - Cryogenic liquids in tank cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... increase more than 25 microns during the 24-hour period; or (ii) Calculated heat transfer rate test. The insulation system must be performance tested as prescribed in § 179.400-4 of this subchapter. When the calculated heat transfer rate test is performed, the absolute pressure in the annular space of the loaded...

  7. 49 CFR 173.319 - Cryogenic liquids in tank cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... increase more than 25 microns during the 24-hour period; or (ii) Calculated heat transfer rate test. The insulation system must be performance tested as prescribed in § 179.400-4 of this subchapter. When the calculated heat transfer rate test is performed, the absolute pressure in the annular space of the loaded...

  8. 49 CFR 173.319 - Cryogenic liquids in tank cars.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... increase more than 25 microns during the 24-hour period; or (ii) Calculated heat transfer rate test. The insulation system must be performance tested as prescribed in § 179.400-4 of this subchapter. When the calculated heat transfer rate test is performed, the absolute pressure in the annular space of the loaded...

  9. 49 CFR 173.319 - Cryogenic liquids in tank cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... increase more than 25 microns during the 24-hour period; or (ii) Calculated heat transfer rate test. The insulation system must be performance tested as prescribed in § 179.400-4 of this subchapter. When the calculated heat transfer rate test is performed, the absolute pressure in the annular space of the loaded...

  10. 49 CFR 173.319 - Cryogenic liquids in tank cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... increase more than 25 microns during the 24-hour period; or (ii) Calculated heat transfer rate test. The insulation system must be performance tested as prescribed in § 179.400-4 of this subchapter. When the calculated heat transfer rate test is performed, the absolute pressure in the annular space of the loaded...

  11. Regional Expertise and Culture Proficiency

    DTIC Science & Technology

    2012-09-01

    Tool for Planners ............................................................................................25 Developing and Testing REC Rating...rated each competency and each behavior as more important than those respondents who had been deployed. We computed an independent sample t- test to...each group, however, it was likely that the homogeneity of variance assumption of the t- test was violated. Therefore, we pooled the variance across

  12. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  13. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  14. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  15. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  16. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  17. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Standard hourly fee rate for laboratory testing, analysis, and other services. 91.37 Section 91.37 Agriculture Regulations of the Department of Agriculture... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and...

  18. 7 CFR 91.39 - Premium hourly fee rates for overtime and legal holiday service.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... overtime work. When analytical testing in a Science and Technology facility requires the services of... (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.39 Premium hourly fee rates for overtime and legal holiday service. (a) When analytical testing in a Science...

  19. 7 CFR 91.39 - Premium hourly fee rates for overtime and legal holiday service.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... overtime work. When analytical testing in a Science and Technology facility requires the services of... (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.39 Premium hourly fee rates for overtime and legal holiday service. (a) When analytical testing in a Science...

  20. 7 CFR 91.39 - Premium hourly fee rates for overtime and legal holiday service.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... overtime work. When analytical testing in a Science and Technology facility requires the services of... (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.39 Premium hourly fee rates for overtime and legal holiday service. (a) When analytical testing in a Science...

  1. 7 CFR 91.39 - Premium hourly fee rates for overtime and legal holiday service.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... overtime work. When analytical testing in a Science and Technology facility requires the services of... (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.39 Premium hourly fee rates for overtime and legal holiday service. (a) When analytical testing in a Science...

  2. Immediate Effects of Smoking on Cardiorespiratory Responses During Dynamic Exercise: Arm Vs. Leg Ergometry.

    PubMed

    Chen, Chien-Liang; Tang, Jing-Shia; Li, Ping-Chia; Chou, Pi-Ling

    2015-01-01

    This study compared the immediate effects of smoking on cardiorespiratory responses to dynamic arm and leg exercises. This randomized crossover study recruited 14 college students. Each participant underwent two sets of arm-cranking (AC) and leg-cycling (LC) exercise tests. The testing sequences of the control trial (participants refrained from smoking for 8 h before testing) and the experimental trial (participants smoked two cigarettes immediately before testing) were randomly chosen. We observed immediate changes in pulmonary function and heart rate variability after smoking and before the exercise test. The participants then underwent graded exercise tests of their arms and legs until reaching exhaustion. We compared the peak work achieved and time to exhaustion during the exercise tests with various cardiorespiratory indices [i.e., heart rate, oxygen consumption (VO2), minute ventilation (VE)]. The differences between the smoking and control trials were calculated using paired t-tests. For the exercise test periods, VO2, heart rate, and VE values were calculated at every 10% increment of the maximal effort time. The main effects of the time and trial, as well as their trial-by-time (4 × 10) interaction effects on the outcome measures, were investigated using repeated measure ANOVA with trend analysis. 5 min after smoking, the participants exhibited reduced forced vital capacities and forced expiratory volumes in the first second (P < 0.05), in addition to elevated resting heart rates (P < 0.001). The high-frequency, low-frequency, and the total power of the heart rate variability were also reduced (P < 0.05) at rest. For the exercise test periods, smoking reduced the time to exhaustion (P = 0.005) and the ventilatory threshold (P < 0.05) in the LC tests, whereas no significant effects were observed in the AC tests. A trend analysis revealed a significant trial-by-time interaction effect for heart rate, VO2, and VE during the graded exercise test (all P < 0.001). Lower VO2 and VE levels were exhibited in the exercise response of the smoking trial than in those of the control LC trials, whereas no discernable inter-trial difference was observed in the AC trials. Moreover, the differences in heart rate and VE response between the LC and AC exercises were significantly smaller after the participants smoked. This study verified that smoking significantly decreased performance and cardiorespiratory responses to leg exercises. However, the negative effects of smoking on arm exercise performance were not as pronounced.

  3. Adhesives: Test Method, Group Assignment, and Categorization Guide for High-Loading Rate Applications - History and Rationale

    DTIC Science & Technology

    2017-04-20

    Categorization Guide for High -Loading- Rate Applications – History and Rationale by Robert Jensen, David Flanagan, Daniel DeSchepper, and Charles...Adhesives: Test Method, Group Assignment, and Categorization Guide for High -Loading- Rate Applications – History and Rationale by Robert Jensen...Categorization Guide for High - Loading-Rate Applications – History and Rationale 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  4. Fatigue crack growth in SA508-CL2 steel in a high temperature, high purity water environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerber, T.L.; Heald, J.D.; Kiss, E.

    1974-10-01

    Fatigue crack growth tests were conducted with 1 in. plate specimens of SA508-CL 2 steel in room temperature air, 550$sup 0$F air and in a 550$sup 0$F, high purity, water environment. Zero-tension load controlled tests were run at cyclic frequencies as low as 0.037 CPM. Results show that growth rates in the simulated Boiling Water Reactor (BWR) water environment are faster than growth rates observed in 550$sup 0$F air and these rates are faster than the room temperature rate. In the BWR water environment, lowering the cyclic frequency from 0.37 to 0.037 CPM caused only a slight increase in themore » fatigue crack growth rate. All growth rates measured in these tests were below the upper bound design curve presented in Section XI of the ASME Code. (auth)« less

  5. Applying Reactive Barrier Technology to Enhance Microbially-mediated Denitrification during Managed Aquifer Recharge

    NASA Astrophysics Data System (ADS)

    Beganskas, S.; Weir, W. B.; Harmon, R. E.; Gorski, G.; Fisher, A. T.; Saltikov, C.; Young, K. S.; Runneals, D.; Teo, E. K.; Stoneburner, B.; Hernandez, J.

    2015-12-01

    We are running field experiments to observe and quantify microbially-mediated water quality improvement via denitrification during infiltration in the shallow subsurface. Nitrate is a pervasive groundwater contaminant, and nitrate removal through denitrification can occur during infiltration in natural and anthropogenic systems, including during managed aquifer recharge (MAR). The rate of denitrification can vary depending on factors such as infiltration rate; previous work suggests that denitrification rates can increase monotonically with infiltration rates until reaching a critical threshold. We are performing controlled field tests of variables that affect denitrification rate, including sampling to link water chemistry changes to microbial ecology and activity. This study explores how microbial activity and denitrification rates respond to different infiltration rates and the presence or absence of a reactive material (wood chips, a carbon source). We are conducting four two-week-long tests, each under different conditions. For each test, we measure bulk infiltration rate (the sum of lateral and vertical infiltration), vertical infiltration rate using heat as a tracer, and water level. We collect surface and subsurface water samples daily, and we collect soil samples at the start and end of each test. For each water sample, we are measuring NO3-, NO2-, NH3, DOC, and N and O isotopes in nitrate. Soil samples will be tested for grain size, total C/N, and the presence of microbiological genes associated with denitrification. These results will expand our knowledge of the conditions under which denitrification occurs by implicating specific microorganisms and physical infiltration parameters. Our design has the potential for additional experimentation with variables that impact water chemistry during infiltration. This study has broad applications for designing MAR systems that effectively improve water supply and water quality.

  6. CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

    NASA Technical Reports Server (NTRS)

    Korona, F. Adam; Norcross, Jason; Conger, Bruce; Navarro, Moses

    2014-01-01

    Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Realtime metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

  7. CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

    NASA Technical Reports Server (NTRS)

    Korona, F. Adam; Norcross, Jason; Conger, Bruce; Navarro, Moses

    2014-01-01

    Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

  8. Testing the effect of specific socioeconomic factors on the ischemic mortality rate. The case of Greece

    PubMed Central

    Mouza, AM

    2008-01-01

    In this paper we present a model to evaluate the effect of certain majors socioeconomic factors (such as alcohol and fat consumption, cigarettes smoking, unemployment rate as a proxy for uncertainty which results frustration, number of passenger cars as a proxy for physical exercise and per capita GDP as a proxy for nutrition quality), to the ischemic mortality rate. Since the existing research works on this field, suffer from the proper model testing, we analytically present all the tests necessary to justify the reliability of the result obtained. For this purpose, after specifying and estimating the model, we applied the specification error test, the linearity, multicollinearity and heteroscedasticity tests, the autocorrelation and stability tests and the ARCH effect test. Finally, we present the aggregate efect of the above socioeconomic factors. In brief, we found that an increase of cigarettes smoked, of fat and alcohol consumption and the number of passenger cars will result to a relevant increase regarding mortality. The latter one is also affected by the changes in unemployment rate. On the other hand, an increase of personal disposable income may negatively affect mortality, by almost the same portion. PMID:18923751

  9. Testing the effect of specific socioeconomic factors on the ischemic mortality rate. The case of Greece.

    PubMed

    Mouza, A M

    2008-01-01

    In this paper we present a model to evaluate the effect of certain majors socioeconomic factors (such as alcohol and fat consumption, cigarettes smoking, unemployment rate as a proxy for uncertainty which results frustration, number of passenger cars as a proxy for physical exercise and per capita GDP as a proxy for nutrition quality), to the ischemic mortality rate. Since the existing research works on this field, suffer from the proper model testing, we analytically present all the tests necessary to justify the reliability of the result obtained. For this purpose, after specifying and estimating the model, we applied the specification error test, the linearity, multicollinearity and heteroscedasticity tests, the autocorrelation and stability tests and the ARCH effect test. Finally, we present the aggregate effect of the above socioeconomic factors. In brief, we found that an increase of cigarettes smoked, of fat and alcohol consumption and the number of passenger cars will result to a relevant increase regarding mortality. The latter one is also affected by the changes in unemployment rate. On the other hand, an increase of personal disposable income may negatively affect mortality, by almost the same portion.

  10. 14 CFR 65.79 - Skill requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.79 Skill requirements. Each applicant for a mechanic certificate or rating must pass an oral and a practical test on the rating he seeks. The tests...

  11. 14 CFR 65.79 - Skill requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.79 Skill requirements. Each applicant for a mechanic certificate or rating must pass an oral and a practical test on the rating he seeks. The tests...

  12. 14 CFR 65.79 - Skill requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.79 Skill requirements. Each applicant for a mechanic certificate or rating must pass an oral and a practical test on the rating he seeks. The tests...

  13. 14 CFR 65.79 - Skill requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.79 Skill requirements. Each applicant for a mechanic certificate or rating must pass an oral and a practical test on the rating he seeks. The tests...

  14. 14 CFR 65.79 - Skill requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... CERTIFICATION: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Mechanics § 65.79 Skill requirements. Each applicant for a mechanic certificate or rating must pass an oral and a practical test on the rating he seeks. The tests...

  15. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  16. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  17. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  18. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  19. Cross-reactions among parabens, para-phenylenediamine, and benzocaine: a retrospective analysis of patch testing.

    PubMed

    Turchin, Irina; Moreau, Linda; Warshaw, Erin; Sasseville, Denis

    2006-12-01

    Parabens are alkyl ester derivatives of para-hydroxybenzoic acid and are the most commonly used preservatives in the cosmetic industry. Cross-reactions with para-amino compounds, namely, benzocaine and para-phenylenediamine (PPD), have been reported but are thought to be extremely rare. To evaluate the rate of cross-reactivity between parabens, PPD, and benzocaine in a population of patients patch-tested in a hospital-based contact dermatitis clinic. A retrospective analysis of 4,368 patients consecutively patch-tested between July 1989 and June 2005. Our study demonstrated that the rate of cross-reactions to parabens in PPD- and benzocaine-positive patients combined is 2%. This cross-reaction rate is significant in the tested population but still falls within the previously reported rates of sensitivity to parabens in the general population (0 to 3.5%).

  20. Loading rate and test temperature effects on fracture of In Situ niobium silicide-niobium composites

    NASA Astrophysics Data System (ADS)

    Rigney, Joseph D.; Lewandowski, John J.

    1996-10-01

    Arc cast, extruded, and heat-treated in situ composites of niobium suicide (Nb5Si3) intermetallic with niobium phases (primary—Nbp and secondary—Nbs) exhibited high fracture resistance in comparison to monolithic Nb5Si3. In toughness tests conducted at 298 K and slow applied loading rates, the fracture process proceeded by the microcracking of the Nb5Si3 and plastic deformation of the Nbp and Nbs phases, producing resistance-curve behavior and toughnesses of 28 MPa√m with damage zone lengths less than 500 μm. The effects of changes in the Nbp yield strength and fracture behavior on the measured toughnesses were investigated by varying the loading rates during fracture tests at both 77 and 298 K. Quantitative fractography was utilized to completely characterize each fracture surface created at 298 K in order to determine the type of fracture mode ( i.e., dimpled, cleavage) exhibited by the Nbp. Specimens tested at either higher loading rates or lower test temperatures consistently exhibited a greater amount of cleavage fracture in the Nbp, while the Nbs, always remained ductile. However, the fracture toughness values determined from experiments spanning six orders of magnitude in loading rate at 298 and 77 K exhibited little variation, even under conditions when the majority of Nbp phases failed by cleavage at 77 K. The changes in fracture mode with increasing loading rate and/or decreasing test temperature and their effects on fracture toughness are rationalized by comparison to existing theoretical models.

Top