Creep and intergranular cracking of Ni-Cr-Fe-C in 360[degree]C argon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angeliu, T.M.; Was, G.S.
1994-06-01
The influence of carbon and chromium on the creep and intergranular (IG) cracking behavior of controlled-purity Ni-xCr-9Fe-yC alloys in 360 C argon was investigated using constant extension rate tension (CERT) and constant load tension (CLT) testing. The CERT test results at 360 C show that the degree of IG cracking increases with decreasing bulk chromium or carbon content. The CLT test results at 360 C and 430 C reveal that, as the amounts of chromium and carbon in solution decrease, the steady-state creep rate increases. The occurrence of severe IG cracking correlates with a high steady-state creep rate, suggesting thatmore » creep plays a role in the IG cracking behavior in argon at 360 C. The failure mode of IG cracking and the deformation mode of creep are coupled through the formation of grain boundary voids that interlink to form grain boundary cavities, resulting in eventual failure by IG cavitation and ductile overload of the remaining ligaments. Grain boundary sliding may be enhancing grain boundary cavitation by redistributing the stress from inclined to more perpendicular boundaries and concentrating stress at discontinuities for the boundaries oriented 45 deg with respect to the tensile axis. Additions of carbon or chromium, which reduce the creep rate over all stress levels, also reduce the amount of IG fracture in CERT experiments. A damage accumulation model was formulated and applied to CERT tests to determine whether creep damage during a CERT test controls failure. Results show that, while creep plays a significant role in CERT experiments, failure is likely controlled by ductile overload caused by reduction in area resulting from grain boundary void formation and interlinkage.« less
Study of IGA/SCC behavior of alloy 600 and 690 SG tubing materials in high temperature solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsujikawa, S.; Yashima, S.; Hattori, T.
1996-09-01
Intergranular attack/stress corrosion cracking (IGA/SCC) of Alloy 600 Steam Generator (SG) tubes in the secondary side has been recognized as a matter of great concern for PWRs. Here, IGA/SCC behavior of Alloy 600 and 690 in high temperature solutions was studied using constant extension rate testing (CERT) method under potentiostatic conditions. The IGA/SCC susceptible regions were investigated as a function of pH and electrode potential. The IGA/SCC resistance of SG tubing materials were ranked as, MA600 = TT600 {much_lt} TT690 in acidic solutions, and MA600 < TT600 < TT690 in alkaline solutions. TT690 showed higher corrosion resistance than MA600 andmore » TT600 in both acidic and alkaline conditions. To verify the results of CERT test, long term model boiler tests were also carried out. The model boiler which consists of combinations of several SG tubing materials and tube support plate configurations, operated for more than 15,000 hrs under the simulated operating plant conditions. The results of destructive examination showed good correspondence with the results of a fundamental study, CERT test. The improved performance of alternate SG tubing material was confirmed.« less
CERTS Microgrid Laboratory Test Bed - PIER Final Project Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eto, Joseph H.; Eto, Joseph H.; Lasseter, Robert
2008-07-25
The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on highmore » fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.« less
Corrosion studies of titanium in borated water for TPX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, D.F.; Pawel, S.J.; DeVan, J.H.
1995-12-31
Corrosion testing was performed to demonstrate the compatibility of the titanium vacuum vessel with borated water. Borated water is proposed to fill the annulus of the double wall vacuum vessel to provide effective radiation shielding. Borating the water with 110 grams of boric acid per liter is sufficient to reduce the nuclear heating in the Toroidal Field Coil set and limit the activation of components external to the vacuum vessel. Constant extension rate tensile (CERT) and electrochemical potentiodynamic tests were performed. Results of the CERT tests confirm that stress corrosion cracking is not significant for Ti-6Al4V or Ti-3AI-2.5V. Welded andmore » unwelded specimens were tested in air and in borated water at 150{degree}C. Strength, elongation, and time to failure were nearly identical for all test conditions, and all the samples exhibited ductile failure. Potentiodynamic tests on Ti-6A1-4V and Ti in borated water as a function of temperature showed low corrosion rates over a wide passive potential range. Further, this passivity appeared stable to anodic potentials substantially greater than those expected from MHD effects.« less
ERIC Educational Resources Information Center
Kovacs, Maria; Sherrill, Joel; George, Charles J.; Pollock, Myrna; Tumuluru, Rameshwari V.; Ho, Vincent
2006-01-01
Objective: To pilot test the acceptability and efficacy of contextual emotion-regulation therapy (CERT), a new, developmentally appropriate intervention for childhood depression, which focuses on the self-regulation of dysphoria. Method: Two samples of convenience (n = 29, n = 2) served to verify some CERT constructs; it was then operationalized…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Was, G.S.
1992-07-01
Stress corrosion cracking tests in constant extension rate tensile (CERT) and constant load tensile (CLT) tests were conducted on Ni-xCr- 9Fe-yC in Ar, water, and a LiOH-boric acid solution. Cr and C improve the resistance of Ni-base alloys to IG cracking in both Ar and water at 360C. Since creep plays a role in IG cracking, one possible explanation for the role of the environment involves its effect on the creep. Experiments were conducted on the role of C in the deformation behavior and failure mode of Ni-16Cr-9Fe. Constant load experiments were conducted on Ni-16Cr-9Fe to determine if the CLTmore » test is more aggressive than CERT. The electron backscattering technique in a SEM is being developed in order to extend the IG cracking studies to grain sizes typical of commercial alloys, 20-30 microns.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Was, G.S.
1992-07-01
Stress corrosion cracking tests in constant extension rate tensile (CERT) and constant load tensile (CLT) tests were conducted on Ni-xCr- 9Fe-yC in Ar, water, and a LiOH-boric acid solution. Cr and C improve the resistance of Ni-base alloys to IG cracking in both Ar and water at 360C. Since creep plays a role in IG cracking, one possible explanation for the role of the environment involves its effect on the creep. Experiments were conducted on the role of C in the deformation behavior and failure mode of Ni-16Cr-9Fe. Constant load experiments were conducted on Ni-16Cr-9Fe to determine if the CLTmore » test is more aggressive than CERT. The electron backscattering technique in a SEM is being developed in order to extend the IG cracking studies to grain sizes typical of commercial alloys, 20-30 microns.« less
77 FR 46439 - Medicare Program; Prior Authorization for Power Mobility Device (PMD) Demonstration
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-03
... DOJ. Medicare Fraud Strike Force teams are a key component of HEAT, since their inception and based on... primary focus of investigation for these strike forces. The Comprehensive Error Rate Testing (CERT... various prior authorization scenarios: Scenario 1: When a submitter sends a prior authorization request to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarver, J.M.; Doherty, P.E.; Doyle, D.M.
1995-12-31
Thermally treated Alloy 690 is the tubing material of choice for replacement steam generators in the United States. Throughout the world, it is manufactured using different melting and thermomechanical processing methods. The influence of different processing steps on the intergranular stress corrosion cracking (IGSCC) behavior of Alloy 690 has not been thoroughly evaluated. Evaluations were performed on Alloy 690 steam generator tubing produced using several different melting practices and thermomechanical processing procedures. The evaluations included extensive microstructural examinations as well as constant extension rate (CERT) tests. The CERT test results indicated that the thermally treated Alloy 690 tubing which wasmore » subjected to higher annealing temperatures displayed the highest degree of resistance to stress corrosion cracking (SCC). Examination of the microstructures indicated that the microstructural changes which are produced by increased annealing temperatures are subtle. In an attempt to further elucidate and quantify the effect of manufacturing processes on corrosion behavior, grain boundary character distribution (GBCD) measurements were performed on the same materials which were CERT tested. Analysis of GBCDs of the samples used in this study indicate that Alloy 690 exhibits a significantly larger fraction of special boundaries as compared to Alloy 600 and Alloy 800, regardless of the processing history of the tubing. Preliminary results indicate that a correlation may exist between processing method, GBCD`s and degree of IGSCC exhibited by the thermally treated samples examined in this study.« less
Chemical exchange rotation transfer imaging of intermediate-exchanging amines at 2 ppm.
Zu, Zhongliang; Louie, Elizabeth A; Lin, Eugene C; Jiang, Xiaoyu; Does, Mark D; Gore, John C; Gochberg, Daniel F
2017-10-01
Chemical exchange saturation transfer (CEST) imaging of amine protons exchanging at intermediate rates and whose chemical shift is around 2 ppm may provide a means of mapping creatine. However, the quantification of this effect may be compromised by the influence of overlapping CEST signals from fast-exchanging amines and hydroxyls. We aimed to investigate the exchange rate filtering effect of a variation of CEST, named chemical exchange rotation transfer (CERT), as a means of isolating creatine contributions at around 2 ppm from other overlapping signals. Simulations were performed to study the filtering effects of CERT for the selection of transfer effects from protons of specific exchange rates. Control samples containing the main metabolites in brain, bovine serum albumin (BSA) and egg white albumen (EWA) at their physiological concentrations and pH were used to study the ability of CERT to isolate molecules with amines at 2 ppm that exchange at intermediate rates, and corresponding methods were used for in vivo rat brain imaging. Simulations showed that exchange rate filtering can be combined with conventional filtering based on chemical shift. Studies on samples showed that signal contributions from creatine can be separated from those of other metabolites using this combined filter, but contributions from protein amines may still be significant. This exchange filtering can also be used for in vivo imaging. CERT provides more specific quantification of amines at 2 ppm that exchange at intermediate rates compared with conventional CEST imaging. Copyright © 2017 John Wiley & Sons, Ltd.
The effect of carbon distribution on deformation and cracking of Ni-16Cr-9Fe-C alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hertzberg, J.L.; Was, G.S.
1995-12-31
Constant extension rate tensile (CERT) tests and constant load tensile (CLT) tests were conducted on controlled purity Ni-16Cr-9Fe-C alloys. The amount and form of carbon were varied in order to investigate the roles of carbon in solution and as intergranular (IG) carbides in the deformation and IG cracking behavior in 360 C argon and primary water environments. Results show that the strength, ductility and creep resistance of these alloys are increased with carbon present in solid solution, while IG cracking on the fracture surface is suppressed. Alloys containing carbon in the form of IG carbides, however, exhibit reduced strength andmore » ductility relative to carbon in solution, while maintaining high IG cracking resistance with respect to carbon-free alloys. CERT results of commercial alloy 600 and controlled purity, carbon containing alloys yield comparable failure strains and IG cracking amounts. CLT comparisons with creep tests of alloy 600 suggest that alloys containing IG carbides are more susceptible to creep than those containing all carbon in solid solution.« less
2017-01-10
or enhance their CERT programs. It also offers suggestions for maintaining span of control and administration of active trained CERT volunteers with...federal frameworks. Lastly, the research examines the value of trained volunteers and offers an example of how they effectively save lives. A. CERT...to provide training that makes sense to the target audience. According to California Office of Emergency Service (CalOES), there are four phases of
CERT Resilience Management Model Capability Appraisal Method (CAM) Version 1.1
2011-10-01
the CERT-RMM CAM V1.1 method is that satisfaction of goals can be determined only upon detailed investigation of the extent to which each...achievement of a specific maturity level or the satisfaction of a process area must mean the same thing for different appraised organizations. The...rate the satisfaction of the goals, based on the extent of practice implementation, for the appraisal reference model and organizational scope
Ossey, Shamika; Sylvers, Sharon; Oksuzyan, Sona; Smith, Lisa V; Frye, Douglas; Family, Leila; Scott, Jannah; King, Jan B
2017-10-01
The Community Emergency Response Team (CERT) concept was initially developed for adult members of the community to help prepare for disasters and minimize damage when disasters occur. CERTs also served as a tool for building community capacity and self-sufficiency by supporting a diverse group of people working together in dealing with challenges affecting their communities. The novel approach to CERTs described here sought to involve high-risk youth from low-socioeconomic status communities in CERTs and first aid and cardiopulmonary resuscitation (CPR) training to help them build ties with communities, stay off the streets, and become leaders in the community. It also helped to provide different perspectives on life, while building more resilient communities better prepared to minimize damage when a disaster strikes. After the successful launch of the first high-risk teen CERT cohort in Watts (27 CERT-trained and 14 first aid/CPR-trained), the project was expanded to other community groups and organizations. Seven additional cohorts underwent CERT and first aid/CPR training in 2013 through 2014. This initiative increased CERT visibility within South Los Angeles. New partnerships were developed between governmental, nongovernmental, and community-based organizations and groups. This model can be used to expand CERT programs to other communities and organizations by involving high-risk teens or other high-risk groups in CERT training. (Disaster Med Public Health Preparedness. 2017;11:605-609).
Toribio, Jesús; Aguado, Leticia; Lorenzo, Miguel; Kharin, Viktor
2017-01-01
Stress corrosion cracking (SCC) of metals is an issue of major concern in engineering since this phenomenon causes many catastrophic failures of structural components in aggressive environments. SCC is even more harmful under cathodic conditions promoting the phenomenon known as hydrogen assisted cracking (HAC), hydrogen assisted fracture (HAF) or hydrogen embrittlement (HE). A common way to assess the susceptibility of a given material to HAC, HAF or HE is to subject a cracked rod to a constant extension rate tension (CERT) test until it fractures in this harsh environment. This paper analyzes the influence of a residual stress field generated by fatigue precracking on the sample’s posterior susceptibility to HAC. To achieve this goal, numerical simulations were carried out of hydrogen diffusion assisted by the stress field. Firstly, a mechanical simulation of the fatigue precracking was developed for revealing the residual stress field after diverse cyclic loading scenarios and posterior stress field evolution during CERT loading. Afterwards, a simulation of hydrogen diffusion assisted by stress was carried out considering the residual stresses after fatigue and the superposed rising stresses caused by CERT loading. Results reveal the key role of the residual stress field after fatigue precracking in the HAC phenomena in cracked steel rods as well as the beneficial effect of compressive residual stress. PMID:28772845
Testing First-Order Logic Axioms in AutoCert
NASA Technical Reports Server (NTRS)
Ahn, Ki Yung; Denney, Ewen
2009-01-01
AutoCert [2] is a formal verification tool for machine generated code in safety critical domains, such as aerospace control code generated from MathWorks Real-Time Workshop. AutoCert uses Automated Theorem Provers (ATPs) [5] based on First-Order Logic (FOL) to formally verify safety and functional correctness properties of the code. These ATPs try to build proofs based on user provided domain-specific axioms, which can be arbitrary First-Order Formulas (FOFs). These axioms are the most crucial part of the trusted base, since proofs can be submitted to a proof checker removing the need to trust the prover and AutoCert itself plays the part of checking the code generator. However, formulating axioms correctly (i.e. precisely as the user had really intended) is non-trivial in practice. The challenge of axiomatization arise from several dimensions. First, the domain knowledge has its own complexity. AutoCert has been used to verify mathematical requirements on navigation software that carries out various geometric coordinate transformations involving matrices and quaternions. Axiomatic theories for such constructs are complex enough that mistakes are not uncommon. Second, adjusting axioms for ATPs can add even more complexity. The axioms frequently need to be modified in order to have them in a form suitable for use with ATPs. Such modifications tend to obscure the axioms further. Thirdly, speculating validity of the axioms from the output of existing ATPs is very hard since theorem provers typically do not give any examples or counterexamples.
Structuring the Chief Information Security Officer Organization
2015-09-07
GP9 Objectively Evaluate Adherence CERT-RMM HRM Human Resource Management CERT-RMM ID Identity Management CERT-RMM IMC Incident Management and...Detect, triage, analyze, respond to, and recover from suspicious events and security incidents Security incident management IMC IR IR-1, IR- 2, IR-3...2015-TN-007 | SOFTWARE ENGINEERING INSTITUTE | CARNEGIE MELLON UNIVERSITY 6 Table 2: Source Acronyms3 CERT-RMM NIST 800-53 C2M2 IMC Incident
Home Computer and Internet User Security
2005-01-01
Information Security Model © 2005 Carnegie Mellon University (Lawrence R. Rogers, Author) Home Computer and Internet User Security...Carnegie Mellon University (Lawrence R. Rogers, Author) Home Computer and Internet User Security Version 1.0.4 – slide 50 Contact Information Lawrence R. Rogers • Email: cert@cert.org CERT website: http://www.cert.org/ ...U.S. Patent and Trademark Office Home Computer and Internet User Security Report Documentation Page Form ApprovedOMB
A Novel Program Trains Community‐Academic Teams to Build Research and Partnership Capacity
Brown, Jen; LeBailly, Susan; McGee, Richard; Bayldon, Barbara; Huber, Gail; Kaleba, Erin; Lowry, Kelly Walker; Martens, Joseph; Mason, Maryann; Nuñez, Abel
2013-01-01
Abstract The Community‐Engaged Research Team Support (CERTS) program was developed and tested to build research and partnership capacity for community‐engaged research (CEnR) teams. Led by the Northwestern University Clinical and Translational Sciences Institute (NUCATS), the goals of CERTS were: (1) to help community‐academic teams build capacity for conducting rigorous CEnR and (2) to support teams as they prepare federal grant proposal drafts. The program was guided by an advisory committee of community and clinical partners, and representatives from Chicago's Clinical and Translational Science Institutes. Monthly workshops guided teams to write elements of NIH‐style research proposals. Draft reviewing fostered a collaborative learning environment and helped teams develop equal partnerships. The program culminated in a mock‐proposal review. All teams clarified their research and acquired new knowledge about the preparation of NIH‐style proposals. Trust, partnership collaboration, and a structured writing strategy were assets of the CERTS approach. CERTS also uncovered gaps in resources and preparedness for teams to be competitive for federally funded grants. Areas of need include experience as principal investigators, publications on study results, mentoring, institutional infrastructure, and dedicated time for research. PMID:23751028
COMPLIANCE AND ENFORCEMENT REGIONAL TRACKING SYSTEM (CERTS)
The Compliance and Enforcement Regional Tracking System (CERTS) is a system that allows Region 10 employees integrated access to information in EPA national media data bases through the LAN system. CERTS will allow you to identify regulated facilities in a given location such as...
Co-evolution of sphingomyelin and the ceramide transport protein CERT.
Hanada, Kentaro
2014-05-01
Life creates many varieties of lipids. The choline-containing sphingophospholipid sphingomyelin (SM) exists ubiquitously or widely in vertebrates and lower animals, but is absent or rare in bacteria, fungi, protists, and plants. In the biosynthesis of SM, ceramide, which is synthesized in the endoplasmic reticulum, is transported to the Golgi region by the ceramide transport protein CERT, probably in a non-vesicular manner, and is then converted to SM by SM synthase, which catalyzes the reaction of phosphocholine transfer from phosphatidylcholine (PtdCho) to ceramide. Recent advances in genomics and lipidomics indicate that the phylogenetic occurrence of CERT and its orthologs is nearly parallel to that of SM. Based on the chemistry of lipids together with evolutionary aspects of SM and CERT, several concepts are here proposed. SM may serve as a chemically inert and robust, but non-covalently interactive lipid class at the outer leaflet of the plasma membrane. The functional domains and peptidic motifs of CERT are separated by exon units, suggesting an exon-shuffling mechanism for the generation of an ancestral CERT gene. CERT may have co-evolved with SM to bypass a competing metabolic reaction at the bifurcated point in the anabolism of ceramide. Human CERT is identical to the splicing variant of human Goodpasture antigen-binding protein (GPBP) annotated as an extracellular non-canonical serine/threonine protein kinase. The relationship between CERT and GPBP has also been discussed from an evolutionary aspect. Moreover, using an analogy of "compatible (or osmoprotective) solutes" that can accumulate to very high concentrations in the cytosol without denaturing proteins, choline phospholipids such as PtdCho and SM may act as compatible phospholipids in biomembranes. This article is part of a Special Issue entitled New Frontiers in Sphingolipid Biology. © 2013.
Consensus on Exercise Reporting Template (CERT): Explanation and Elaboration Statement.
Slade, Susan C; Dionne, Clermont E; Underwood, Martin; Buchbinder, Rachelle
2016-10-05
Exercise is effective for prevention and management of acute and chronic health conditions. However, trial descriptions of exercise interventions are often suboptimal, leaving readers unclear about the content of effective programmes. To address this, the 16-item internationally endorsed Consensus on Exercise Reporting Template (CERT) was developed. The aim is to present the final template and provide an Explanation and Elaboration Statement to operationalise the CERT. Development of the CERT was based on the EQUATOR Network methodological framework for developing reporting guidelines. We used a modified Delphi technique to gain consensus of international exercise experts and conducted 3 sequential rounds of anonymous online questionnaires and a Delphi workshop. The 16-item CERT is the minimum data set considered necessary to report exercise interventions. The contents may be included in online supplementary material, published as a protocol or located on websites and other electronic repositories. The Explanation and Elaboration Statement is intended to enhance the use, understanding and dissemination of the CERT and presents the meaning and rationale for each item, together with examples of good reporting. The CERT is designed specifically for the reporting of exercise programmes across all evaluative study designs for exercise research. The CERT can be used by authors to structure intervention reports, by reviewers and editors to assess completeness of exercise descriptions and by readers to facilitate the use of the published information. The CERT has the potential to increase clinical uptake of effective exercise programmes, enable research replication, reduce research waste and improve patient outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
49 CFR 22.21 - Participation criteria.
Code of Federal Regulations, 2010 CFR
2010-10-01
... certification form is available at http://www.osdbu.dot.gov/financial/docs/Cert_Debarment_DOT_F_2309-1.pdf. (j... available at http://www.osdbu.dot.gov/financial/docs/Cert_Drug-Free_DOT_F_2307-1.pdf.; and (k) It must.../financial/docs/Cert_Lobbying_DOT_F_2308-1.pdf. ...
NASA Astrophysics Data System (ADS)
Fournier, L.; Savoie, M.; Delafosse, D.
2007-06-01
The low cycle fatigue (LCF) behaviour of precipitation-strengthened A-286 austenitic stainless steel was first investigated at room temperature under 0.2% plastic strain control. LCF led to hardening for the first 20 cycles and then to significant softening. LCF-induced dislocation microstructure was characterized using both bright and dark-field imaging techniques in transmission electron microscopy. Cycling softening was correlated with the formation of precipitate-free localized deformation bands. The effect of these precipitate-free localized deformation bands on A-286 stress corrosion cracking (SCC) behaviour in PWR primary water was then examined by means of constant extension rate tensile (CERT) tests at 320 °C and 360 °C. Comparative CERT tests were performed on companion specimens with similar yield stress but pre-fatigued to a few cycles (4-8) or between 125 and 200 cycles. Specimens pre-fatigued to a few cycles with no precipitate-free localized deformation bands exhibited little susceptibility to intergranular SCC (IGSCC). In contrast, the presence of precipitate-free localized deformation bands formed by pre-fatigue to between 125 and 200 cycles strongly promoted IGSCC. The interest of the approach used in this study is to provide insight into the role of localized deformation in irradiation assisted stress corrosion cracking.
Overview of the CERT Resilience Management Model (CERT-RMM)
2014-01-23
Management Model (CERT®-RMM) Jim Cebula Technical Manager - Cyber Risk Management , CERT® Division Jim Cebula is the Technical Manager of the...Cyber Risk Management team in the Cyber Security Solutions Directorate of the CERT Division at the Software Engineering Institute (SEI), a unit of...Carnegie Mellon University. Cebula’s current activities include risk management methods along with assessment and management of operational
Bandet, Cécile L; Mahfouz, Rana; Véret, Julien; Sotiropoulos, Athanassia; Poirier, Maxime; Giussani, Paola; Campana, Mélanie; Philippe, Erwann; Blachnio-Zabielska, Agnieszka; Ballaire, Raphaëlle; Le Liepvre, Xavier; Bourron, Olivier; Berkeš, Dušan; Górski, Jan; Ferré, Pascal; Le Stunff, Hervé; Foufelle, Fabienne; Hajduch, Eric
2018-05-14
One main mechanism of insulin resistance (IR), a key feature of type-2 diabetes, is the accumulation of saturated fatty acids (FA) in muscles of obese and type-2 diabetic patients. Understanding the mechanism underlying lipid-induced IR is therefore a crucial challenge. Saturated FA are metabolized into lipid-derivatives called ceramides and their accumulation plays a central role in the development of muscle IR. Ceramides are produced in the endoplasmic reticulum (ER) and transported to the Golgi through a transporter called CERT, where they are converted into different sphingolipid species. We show here that CERT protein expression is reduced in all insulin resistance models studied due to a caspase-dependent cleavage. Inhibiting CERT activity in vitro potentiates the deleterious action of lipotoxicity on insulin signaling whereas overexpression of CERT in vitro or in vivo increases muscle ceramide content and improves insulin signaling. In addition, inhibition of caspase activity prevents ceramide-induced insulin signaling defects in C2C12 muscle cells. Altogether, these results demonstrate the importance of a physiological ER to Golgi ceramide traffic to preserve muscle cell insulin signaling and identifies CERT as a major actor in this process. © 2018 by the American Diabetes Association.
Study of the IGA/SCC behavior of Alloy 600 and 690 in high temperature solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsujikawa, S.; Yashima, S.; Ohnishi, K.
1995-09-01
IGA/SCC of Alloy 600 steam generator (SG) tubes in the secondary side has been recognized as a matter of great concern for PWRs. IGA/SCC behavior of Alloy 600 and 690 in high temperature solutions were studied using CERT method under potentiostatic conditions. The IGA/SCC susceptible regions were investigated as the function of pH and electrode potential. To understand the cause of IGA/SCC, the electrochemical measurements and surface film analysis were also performed in acidic and alkaline solutions. To verify the results of CERT test, the long term model boiler tests were also carried out. Thermally treated Alloy 690 showed highermore » IGA/SCC resistance than Alloy 600 under both acid and alkaline conditions.« less
A Formal Language for Cryptographic Protocol Requirements
1996-01-01
L;KAB; AgKBS ; fA; TAgKAB (4) B sends to A: fTA + 1gKAB Here A and B are two principals. By sending the rst message, A requests of the...A: CertB; fAKBgKA ; algchoiceB; fmd (fAKBgKA ; algchoiceB ; NA; alglistA)gK1 B (3) A sends to B: fAKAgKB ; fmd (fAKAgKB ; fAKBgKA)gK1 A CertX is a...alglistA 3. B sends to C: CertB ; fAKBgKC ; algchoiceB; fmd (fAKBgKC ; algchoiceB ; NA; alglistA)gK1 B (intercepted by I) 4. IB sends to A : CertB
Cyberspace: Devolution and Recovery
2011-03-23
time of the source of the burst and we do not know if it was accidental, an act of God , or a malicious attack. 28 The remainder of a speech like...Security 15 Mailing List, Federal Vulnerability Knowledgebase (VKB), US-CERT Portal, US-CERT Einstein Program, Internet Health and Status Service...The US-CERT portal is a website dedicated to sharing relevant information with participants. The Einstein Program is a program that allows for the
Characterization of cracking behavior using posttest fractographic analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobayashi, T.; Shockey, D.A.
A determination of time to initiation of stress corrosion cracking in structures and test specimens is important for performing structural failure analysis and for setting inspection intervals. Yet it is seldom possible to establish how much of a component's lifetime represents the time to initiation of fracture and how much represents postinitiation crack growth. This exploratory research project was undertaken to examine the feasibility of determining crack initiation times and crack growth rates from posttest examination of fracture surfaces of constant-extension-rate-test (CERT) specimens by using the fracture reconstruction applying surface topography analysis (FRASTA) technique. The specimens used in this studymore » were Type 304 stainless steel fractured in several boiling water reactor (BWR) aqueous environments. 2 refs., 25 figs., 2 tabs.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-24
...: Implementation of the iCERT Labor Certification Registry for the H-1B, H-1B1, E-3, H-2A, H-2B and Permanent Labor... new initiative to make available to the general public appropriately redacted copies of H-1B, H-1B1, E-3, H-2A, H-2B and permanent labor certification documents through its iCERT Visa Portal System. This...
Stress corrosion cracking of sensitized AA5083 (Al-4.5Mg-1.0Mn)
NASA Astrophysics Data System (ADS)
Searles, J. L.; Gouma, P. I.; Buchheit, R. G.
2001-11-01
The AA5083 (Al-4.4Mg-0.7Mn-0.15Cr) alloy is a nonheat-treatable aluminum alloy known for its excellent corrosion resistance. However, it can become susceptible to intergranular stress corrosion cracking (IGSCC) when exposed to temperatures ranging from 50 °C to 200 °C for sufficient lengths of time. This IGSCC is widely believed to be associated with dissolution of the electrochemically active β phase, Al3Mg2, which is precipitated on grain boundaries. Recently, alternative mechanisms have been invoked related to hydrogen effects and/or free Mg segregation or depletion in the grainboundary regions. To establish a baseline for the sensitization effect, constant-extension-rate tests (CERTs) were conducted under open-circuit conditions and under potential control in 3.5 pct NaCl on samples isothermally treated at 150 °C. To aid in interpreting the CERT results, grain-boundary precipitation and solute depletion were characterized by transmission electron microscopy (TEM). Additionally, the electrochemical behavior of the β phase was characterized by anodic polarization of the intermetallic compound synthesized in bulk form. In CERTs under open-circuit conditions, the measured ductility depended strongly on sensitization time, reaching a minimum at 189 hours, followed by a slight increase at longer times. This trend correlated well with the fractional coverage of β phase on grain boundaries, which increased up to 189 hours, where it existed with nearly continuous coverage. At longer times, this film coarsened and became discontinuous. Correspondingly, some resistance to IGSCC was recovered. In polarization experiments, bulk synthesized β phase was found to be spontaneously passive from its corrosion potential (-1.40 VSCE) up to about -0.92 VSCE, where passivity was observed to break down. Sensitized AA5083 samples polarized below the β-phase breakdown potential showed almost no evidence of IGSCC, indicating that a high β dissolution rate is a requirement for IGSCC. Mg-depleted zones were observed along grain boundaries in sensitized alloys, but a clear role for solute depletion in IGSCC could not be defined on the basis of the results developed in this study.
Oxygen Concentration Flammability Threshold Tests for the Constellation Program
NASA Technical Reports Server (NTRS)
Williams, James H.
2007-01-01
CEV atmosphere will likely change because craft will be used as LEO spacecraft, lunar spacecraft, orbital spacecraft. Possible O2 % increase and overall pressure decrease pressure vessel certs on spacecraft. Want 34% minimum threshold. Higher, better when atmosphere changes. WSTF suggests testing all materials/components to find flammability threshold, pressure and atmosphere.
US-CERT Control System Center Input/Output (I/O) Conceputal Design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2005-02-01
This document was prepared for the US-CERT Control Systems Center of the National Cyber Security Division (NCSD) of the Department of Homeland Security (DHS). DHS has been tasked under the Homeland Security Act of 2002 to coordinate the overall national effort to enhance the protection of the national critical infrastructure. Homeland Security Presidential Directive HSPD-7 directs the federal departments to identify and prioritize critical infrastructure and protect it from terrorist attack. The US-CERT National Strategy for Control Systems Security was prepared by the NCSD to address the control system security component addressed in the National Strategy to Secure Cyberspace andmore » the National Strategy for the Physical Protection of Critical Infrastructures and Key Assets. The US-CERT National Strategy for Control Systems Security identified five high-level strategic goals for improving cyber security of control systems; the I/O upgrade described in this document supports these goals. The vulnerability assessment Test Bed, located in the Information Operations Research Center (IORC) facility at Idaho National Laboratory (INL), consists of a cyber test facility integrated with multiple test beds that simulate the nation's critical infrastructure. The fundamental mission of the Test Bed is to provide industry owner/operators, system vendors, and multi-agency partners of the INL National Security Division a platform for vulnerability assessments of control systems. The Input/Output (I/O) upgrade to the Test Bed (see Work Package 3.1 of the FY-05 Annual Work Plan) will provide for the expansion of assessment capabilities within the IORC facility. It will also provide capabilities to connect test beds within the Test Range and other Laboratory resources. This will allow real time I/O data input and communication channels for full replications of control systems (Process Control Systems [PCS], Supervisory Control and Data Acquisition Systems [SCADA], and components). This will be accomplished through the design and implementation of a modular infrastructure of control system, communications, networking, computing and associated equipment, and measurement/control devices. The architecture upgrade will provide a flexible patching system providing a quick ''plug and play''configuration through various communication paths to gain access to live I/O running over specific protocols. This will allow for in-depth assessments of control systems in a true-to-life environment. The full I/O upgrade will be completed through a two-phased approach. Phase I, funded by DHS, expands the capabilities of the Test Bed by developing an operational control system in two functional areas, the Science & Technology Applications Research (STAR) Facility and the expansion of various portions of the Test Bed. Phase II (see Appendix A), funded by other programs, will complete the full I/O upgrade to the facility.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prashek, Jennifer; Bouyain, Samuel; Fu, Mingui
De novo synthesis of the sphingolipid sphingomyelin requires non-vesicular transport of ceramide from the endoplasmic reticulum to the Golgi by the multidomain protein ceramide transfer protein (CERT). CERT's N-terminal pleckstrin homology (PH) domain targets it to the Golgi by binding to phosphatidylinositol 4-phosphate (PtdIns(4)P) in the Golgi membrane, whereas its C-terminal StAR-related lipid transfer domain (START) carries out ceramide transfer. Hyperphosphorylation of a serine-rich motif immediately after the PH domain decreases both PtdIns(4)P binding and ceramide transfer by CERT. This down-regulation requires both the PH and START domains, suggesting a possible inhibitory interaction between the two domains. In this studymore » we show that isolated PH and START domains interact with each other. The crystal structure of a PH–START complex revealed that the START domain binds to the PH domain at the same site for PtdIns(4)P-binding, suggesting that the START domain competes with PtdIns(4)P for association with the PH domain. We further report that mutations disrupting the PH–START interaction increase both PtdIns(4)P-binding affinity and ceramide transfer activity of a CERT-serine–rich phosphorylation mimic. We also found that these mutations increase the Golgi localization of CERT inside the cell, consistent with enhanced PtdIns(4)P binding of the mutant. Collectively, our structural, biochemical, and cellular investigations provide important structural insight into the regulation of CERT function and localization.« less
77 FR 38306 - GFIRST Conference Stakeholder Evaluation
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-27
...), National Cyber Security Division (NCSD), United States Computer Emergency Readiness Team (US-CERT) will...- CERT, [email protected] . SUPPLEMENTARY INFORMATION: GFIRST is DHS's premier cyber conference and continually seeks to enhance collaborative efforts among cyber constituencies, partners, and stakeholders. The...
2005 8th Annual Systems Engineering Conference. Volume 1, Tuesday
2005-10-27
Services NCES Discovery Services Federated Search Denotes interface Service NCCP Oktoberfest 2004 101 Task: Global Strike Mission Planning NCCP Oktoberfest...Enterprise Service Management Security Services NCES Discovery Services Federated Search Service Test, cert and accreditation needs to be focused on small
Disaster Training: Monroe Community College
ERIC Educational Resources Information Center
McConkey, Diane
2005-01-01
This article discusses Monroe Community College's CERT (Community Emergency Response Team), a program designed to help neighborhoods and work sites prepare for effective disaster response through training and planning. The program requires 24 hours of theoretical and hands-on practice in self-help and mutual-aid emergency functions. CERT personnel…
CERT Resilience Management Model (CERT-RMM) V1.1: NIST Special Publication Crosswalk Version 1
2011-11-01
Organization for Standards ( ISO ) and International Electrotechnical Commission (IEC) 27000 series, COBIT, the British Standards Institution’s BS 25999...and ISO 24762 • includes quantitative process measurements that can be used to ensure operational resilience processes are performing as intended
Bobby Kannan, M; Singh Raman, R K; Witte, F; Blawert, C; Dietzel, W
2011-02-01
Applications of magnesium alloys as biodegradable orthopaedic implants are critically dependent on the mechanical integrity of the implant during service. In this study, the mechanical integrity of an AZ91 magnesium alloy was studied using a constant extension rate tensile (CERT) method. The samples in two different geometries that is, circumferentially notched (CN), and circumferentially notched and fatigue cracked (CNFC), were tested in air and in simulated body fluid (SBF). The test results show that the mechanical integrity of the AZ91 magnesium alloy decreased substantially (∼50%) in both the CN and CNFC samples exposed to SBF. Fracture surface analysis revealed secondary cracks suggesting stress corrosion cracking susceptibility of the alloy in SBF. Copyright © 2010 Wiley Periodicals, Inc.
Creating a Campus Based Community Emergency Response Team (CERT)
ERIC Educational Resources Information Center
Connolly, Maureen
2012-01-01
This article provides the reader with information regarding forming a community emergency response team (CERT) at a community college. College public safety departments are efficient entities in ordinary times. However, recent events at community colleges across the country have shown that there have been situations where their capabilities have…
2014-06-01
27000 series, COBIT, the British Standards Institution’s BS 25999, and ISO 24762 includes quantitative process measurements that can be used to...the NIST special publications 800 series, the International Organization for Standards ( ISO ) and International Electrotechnical Commission (IEC
4-H Teen Community Emergency Response Team (CERT)
ERIC Educational Resources Information Center
Black, Lynette; Powell, Pamela
2012-01-01
The Community Emergency Response Team (CERT) program is designed to train Americans to safely help themselves and their community in the event of a widespread disaster. This program is designed for adults. Despite youth increasingly becoming recognized as valuable resources, able to equally partner with adults in leadership and decision-making…
49 CFR 572.181 - General description.
Code of Federal Regulations, 2011 CFR
2011-10-01
... assembly Drawing number Head Assembly 175-1000 Neck Assembly Test/Cert 175-2000 Neck Bracket Including..., dated February 2008. (c) Weights of body segments (head, neck, upper and lower torso, arms and upper and... the convenience of the user, the added and revised text is set forth as follows: § 572.181 General...
78 FR 52912 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-27
... DEMI to be effective 8/19/2013. Filed Date: 8/19/13. Accession Number: 20130819-5103. Comments Due: 5 p...: Dominion Energy Brayton Point, LLC. Description: Compliance Filing--Amended Cert of Concurrence Chg to DEMI...: Dominion Retail, Inc. submits tariff filing per 35: Compliance--Amend Cert of Concurrence Chg to DEMI to be...
Understand the Big Picture So You Can Plan for Network Security
ERIC Educational Resources Information Center
Cervone, Frank
2005-01-01
This article discusses network security for libraries. It indicates that there were only six exploit (security exposure) problems, worldwide, reported to the CERT Coordination Center back in 1988. In that year, the CERT had just been established to provide a clearinghouse for exchanging information about network security problems. By 2003, the…
75 FR 8413 - Agency Forms Submitted for OMB Review, Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
..., consisting of RRB Form(s) AA-3, Application for Spouse/Divorced Spouse Annuity and AA-3cert, Application.... The RRB currently uses the electronic AA-3cert, Application Summary and Certification process and manual Form AA-3, Application for Spouse/ Divorced Spouse Annuity, to obtain the information needed to...
1991-09-01
iv III. THE ANALYTIC HIERARCHY PROCESS ..... ........ 15 A. INTRODUCTION ...... ................. 15 B. THE AHP PROCESS ...... ................ 16 C...INTRODUCTION ...... ................. 26 B. IMPLEMENTATION OF CERTS USING AHP ........ .. 27 1. Consistency ...... ................ 29 2. User Interface...the proposed technique into a Decision Support System. Expert Choice implements the Analytic Hierarchy Process ( AHP ), an approach to multi- criteria
CERT tribal internship program. Final intern report: Maria Perez, 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
Historically, American Indian Tribes have lacked sufficient numbers of trained, technical personnel from their communities to serve their communities; tribal expertise in the fields of science, business and engineering being extremely rare and programs to encourage these disciplines almost non-existent. Subsequently, Tribes have made crucial decisions about their land and other facets of Tribal existence based upon outside technical expertise, such as that provided by the United States government and/or private industries. These outside expert opinions rarely took into account the traditional and cultural values of the Tribes being advised. The purpose of this internship was twofold: Create and maintainmore » a working relationship between CERT and Colorado State University (CSU) to plan for the Summit on Tribal human resource development; and Evaluate and engage in current efforts to strengthen the Tribal Resource Institute in Business, Engineering and Science (TRIBES) program. The intern lists the following as the project results: Positive interactions and productive meetings between CERT and CSU; Gathered information from Tribes; CERT database structure modification; Experience as facilitator in participating methods; Preliminary job descriptions for staff of future TRIBES programs; and Additions for the intern`s personal database of professional contacts and resources.« less
Understanding the Value of a Computer Emergency Response Capability for Nuclear Security
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gasper, Peter Donald; Rodriguez, Julio Gallardo
The international nuclear community has a great understanding of the physical security needs relating to the prevention, detection, and response of malicious acts associated with nuclear facilities and radioactive material. International Atomic Energy Agency (IAEA) Nuclear Security Recommendations (INFCIRC_225_Rev 5) outlines specific guidelines and recommendations for implementing and maintaining an organization’s nuclear security posture. An important element for inclusion into supporting revision 5 is the establishment of a “Cyber Emergency Response Team (CERT)” focused on the international communities cybersecurity needs to maintain a comprehensive nuclear security posture. Cybersecurity and the importance of nuclear cybersecurity require that there be a specificmore » focus on developing an International Nuclear CERT (NS-CERT). States establishing contingency plans should have an understanding of the cyber threat landscape and the potential impacts to systems in place to protect and mitigate malicious activities. This paper will outline the necessary components, discuss the relationships needed within the international community, and outline a process by which the NS-CERT identifies, collects, processes, and reports critical information in order to establish situational awareness (SA) and support decision-making« less
Supporting the Use of CERT (registered trademark) Secure Coding Standards in DoD Acquisitions
2012-07-01
Capability Maturity Model IntegrationSM (CMMI®) [Davis 2009]. SM Team Software Process, TSP, and Capability Maturity Model Integration are service...STP Software Test Plan TEP Test and Evaluation Plan TSP Team Software Process V & V verification and validation CMU/SEI-2012-TN-016 | 47...Supporting the Use of CERT® Secure Coding Standards in DoD Acquisitions Tim Morrow ( Software Engineering Institute) Robert Seacord ( Software
29 CFR 780.134 - Performance “on a farm” generally.
Code of Federal Regulations, 2011 CFR
2011-07-01
... performed on a farm, such as “delivery to market,” is necessarily excluded, therefore, when performed by someone other than a farmer (see Farmers Reservoir Co. v. McComb, 337 U.S. 755; Chapman v. Durkin, 214 F. 2d 360, cert. denied 348 U.S. 897; Fort Mason Fruit Co. v. Durkin, 214 F. 2d 363, cert. denied 348 U...
29 CFR 780.134 - Performance “on a farm” generally.
Code of Federal Regulations, 2010 CFR
2010-07-01
... performed on a farm, such as “delivery to market,” is necessarily excluded, therefore, when performed by someone other than a farmer (see Farmers Reservoir Co. v. McComb, 337 U.S. 755; Chapman v. Durkin, 214 F. 2d 360, cert. denied 348 U.S. 897; Fort Mason Fruit Co. v. Durkin, 214 F. 2d 363, cert. denied 348 U...
CERT TST December 2015 Visit Summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Little, Robert Currier; Bailey, Teresa S.; Gamblin, G. Todd
2016-01-25
The annual PSAAP II TST visit to Texas A&M’s CERT Center was held on December 1-3, 2015. The agenda for the visit is attached. Non-TAMU attendees were: TST Members – Teresa Bailey (LLNL), Todd Gamblin (LLNL), Bob Little (LANL) – Chair, Chad Olinger (LANL), Shawn Pautz (SNL), Alan Williams (SNL);Other Lab staff – Skip Kahler (LANL), Ana Kupresanin (LLNL), and Rob Lowrie (LANL); AST Members – Nelson Hoffman (LANL) and Bob Voigt (Leidos) The TST wishes to express our appreciation to all involved with CERT for the high-quality posters and presentations and for the attention to logistics that enabled amore » successful visit. We have broken our comments into four sections: (1) Kudos, (2) Recommendations, (3) Feedback on Priorities for April Review, and (4) Follow-Up Activities with Labs.« less
Defining a Progress Metric for CERT RMM Improvement
2017-09-14
Table 1) should be used along with clear guidance on what is to be measured, to avoid subjective interpretations by different project managers . In some...products for each CERT-RMM practice. Project managers should be trained to help the organization improve the accuracy and consistency of its reporting...and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188), Washington, DC 20503. 1. AGENCY USE ONLY (Leave Blank) 2
29 CFR 780.156 - Transportation of farm products from the fields or farm.
Code of Federal Regulations, 2010 CFR
2010-07-01
...” meaning of agriculture, regardless of whether the transportation is included as “delivery to storage or to... the following cases, among others: Maneja v. Waialua, 349 U.S. 254; NLRB v. Olaa Sugar Co., 242 F. 2d..., 214 F. 2d 360, cert. denied, 348 U.S. 897; Fort Mason Fruit Co. v. Durkin, 214 F. 2d 363, cert. denied...
29 CFR 780.156 - Transportation of farm products from the fields or farm.
Code of Federal Regulations, 2011 CFR
2011-07-01
...” meaning of agriculture, regardless of whether the transportation is included as “delivery to storage or to... the following cases, among others: Maneja v. Waialua, 349 U.S. 254; NLRB v. Olaa Sugar Co., 242 F. 2d..., 214 F. 2d 360, cert. denied, 348 U.S. 897; Fort Mason Fruit Co. v. Durkin, 214 F. 2d 363, cert. denied...
2017 Emerging Technology Domains Risk Survey
2017-10-01
REV-03.18.2016.0 2017 Emerging Technology Domains Risk Survey Daniel Klinedinst Joel Land Kyle O’Meara October 2017 TECHNICAL REPORT CMU/SEI...to the CERT/CC 2016 Emerging Technol- ogy Domains Risk Survey [King 2016]. This list does not supersede previous reports. Many of the previously... Survey [King 2016]. Table 1: New and Emerging Technologies Gartner’s 2015 List of New Technology CERT’s List of Emerging Domains Trust Boundary
2012-11-01
Tradeoff Analysis Method; ATAM, Capability Maturity Model , Capability Maturity Modeling , Carnegie Mellon, CERT, CERT Coordination Center, CMM, CMMI...Hermansen, Product Design, Sphere of Influence (https://www.SphereOfInfluence.com) Joel McAteer, Information Assurance Manager, Modeling ...use of them does introduce some challenges related to delivering software features rapidly and/or in- crementally . • Challenges with respect to
Measuring Operational Resilience Using the CERT(Registered) Resilience Management Model
2010-09-01
such as ISO 27002 [ ISO 2005]) and then measure the implementation and performance of practices contained in the standard. This checklist-based ap...Security techniques – Code of practice for information security management. ISO /IEC 27002 :2005, June 2005. Also known as ISO /IEC 17799:2005. [ ISO 2007...Table 23: ISO 15939 Process Activities and Tasks 54 Table 24: CERT-RMM Measurement and Analysis Process Area Goals and Practices 55 CMU/SEI
Educational initiative for EE/RE engineering skills: Solar Two student interns. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norbeck, J.M.
1997-07-01
The US Department of Energy sponsored five student interns from the University of California, Riverside, College of Engineering to work during the summer of 1996 at the Solar Two Energy facility in the Mojave Desert. Through the DOE intern program, engineering students supported the Solar Two Project under the supervision of engineers from Southern California Edison. The prime purpose was to provide outreach and educational support for expanding interactions with university students to increase awareness of careers in renewable energy and energy efficiency fields. The College of Engineering-Center for Environmental Research and Technology (CE-CERT) coordinated this project. CE-CERT is primarilymore » a research facility focusing on air pollution and energy efficiency. CE-CERT serves undergraduate and graduate students by employing them on research projects, supporting them in the research and experimentation required for Senior Design Projects, and sponsoring them in student engineering competitions.« less
Use of adaptive walls in 2D tests
NASA Technical Reports Server (NTRS)
Archambaud, J. P.; Chevallier, J. P.
1984-01-01
A new method for computing the wall effects gives precise answers to some questions arising in adaptive wall concept applications: length of adapted regions, fairings with up and downstream regions, residual misadjustments effects, reference conditions. The acceleration of the iterative process convergence and the development of an efficient technology used in CERT T2 wind tunnels give in a single run the required test conditions. Samples taken from CAST 7 tests demonstrate the efficiency of the whole process to obtain significant results with considerations of tridimensional case extension.
NASA Technical Reports Server (NTRS)
Archambaud, J. P.; Dor, J. B.; Mignosi, A.; Lamarche, L.
1986-01-01
The test series was carried out at ONERA/CERT at the T2 wind tunnel in September 1984. The objective of this series was to minimize wall interference through a bidimensional adaptation around the models, inducing tridimensional flows. For this, three different models were used, measuring either the pressures or the forces and moment of pitch (balance). The adaptation was derived from a correction computation in the compressible axisymmetric tridimensional.
CERT Resilience Management Model - Mail-Specific Process Areas: Mail Revenue Assurance (Version 1.0)
2014-08-01
Revenue Assurance ( MRA ), Mail Transportation (MT), and Mail Delivery (MD)—were accepted by the USPIS, as well as an initial draft of the MRA PA...versions of two complete PAs, MI [Allen 2014b] and MRA , were accepted by the USPIS. Following this initial effort, the USPIS asked CERT to extend the...Revenue Assurance ( MRA ) is to ensure that the USPS is compensated for all mail that is accepted, transported, and delivered. Outline MRA:SG1
On the influence of manufacturing practices on the SCC behavior of Alloy 690 steam generator tubing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doherty, P.E.; Doyle, D.M.; Sarver, J.M.
1996-12-31
Thermally treated (TT) Alloy 690 is the tubing materials of choice for replacement steam generators (RSGs) throughout the world. It is manufactured using a variety of processing methods with regards to melt practice and thermomechanical forming. Studies assessing the IGSCC resistance of Alloy 690 TT SG tubing have identified a variability in the corrosion performance of nominally identical alloys. While tubing of comparable bulk chemistry may exhibit variations in microchemistry as a result of different melt practice, the correlation between melt practice and SCC resistance is difficult to assess due to other contributing factors. The other contributing factors are identifiedmore » in this investigation as microstructural features whose generation is dependent on features of particular strain-anneal forming methods by which SG tubes are fabricated. In this study the microstructural characteristics which appear to affect inservice corrosion performance of Alloy 690 TT SG tubes were evaluated. The studies included extensive microstructural examinations in addition to CERT tests performed on actual Alloy 690 TT nuclear SG tubing. The CERT test results indicate that Alloy 690 TT tubing processed at higher mill anneal temperatures display the highest degree of stress corrosion cracking (SCC) resistance. This observation is discussed with reference to carbide distributions, textural aspects and grain boundary orientation character.« less
Evaluation of CERT Secure Coding Rules through Integration with Source Code Analysis Tools
2008-06-01
Fortify SCA 3 2.2 Compass / ROSE 6 3 Project Analysis 9 3.1 Measuring and Analysis 9 4 Results 13 4.1 Fortify Results 13 4.1.1 CERT C++ Secure...Fortify C Rules 23 Appendix B Fortify C++ Rules 35 Appendix C C Rules Implemented in Compass Rose 43 Appendix D ROSE C++ Rules 51 References...to Daniel Quinlan at Lawrence Livermore National Laboratory for all his help getting us up and running with Compass /ROSE. Thanks to our SEI editor
2013-10-01
Technology Assets • EXD:SG2 Manage Risks Due to External Dependencies (SP1-SP2) • EXD:SG3.SP4 Formalize Relationships 5 . Data Backup Plan and...Information Access Management (C.E.R. § 164.308(a)(4)) 11 4.5. Security Awareness and Training (C.E.R. § 164.308(a)( 5 )) 13 4.6. Security Incident Procedures...for managing operational resilience. It has two primary objectives: • Establish the convergence of operational risk and resilience management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vittal, Vijay
2015-11-04
The Consortium for Electric Reliability Technology Solutions (CERTS) was formed in 1999 in response to a call from U.S. Congress to restart a federal transmission reliability R&D program to address concerns about the reliability of the U.S. electric power grid. CERTS is a partnership between industry, universities, national laboratories, and government agencies. It researches, develops, and disseminates new methods, tools, and technologies to protect and enhance the reliability of the U.S. electric power system and the efficiency of competitive electricity markets. It is funded by the U.S. Department of Energy’s Office of Electricity Delivery and Energy Reliability (OE). This reportmore » provides an overview of PSERC and CERTS, of the overall objectives and scope of the research, a summary of the major research accomplishments, highlights of the work done under the various elements of the NETL cooperative agreement, and brief reports written by the PSERC researchers on their accomplishments, including research results, publications, and software tools.« less
NOGA Online: a USGS resource for energy GIS data and services
Biewick, Laura; Gunther, Greg L.
2003-01-01
The PowerPoint presentation in this report was given at the BLM Resource Management Tools Conference in Phoenix, Arizona, April, 2003. Some diagrams that appeared in the original presentation have been updated in this report. It informs that the U.S. Geological Survey (USGS) Central Energy Resources Team (CERT) in Denver, Colorado, is providing National Oil and Gas Assessment (NOGA) results online at http://energy.cr.usgs.gov/oilgas/noga/. Available at this site are recently completed assessments of the potential for undiscovered oil and natural gas resources of five priority provinces (Montana Thrust Belt, Powder River Basin, San Juan Basin, Southwestern Wyoming, Uinta-Piceance) to meet the requirements of the Energy Policy and Conservation Act of 2000 (EPCA 2000). High demand for current assessment results and for the entirely digital, 1995 NOGA results for other provinces, prompted CERT to develop an internet map application using ArcIMS to deliver geologic data to the public. CERT continues to work on assessing oil and natural gas resources of priority basins in the United States; assessment results and GIS layers are made available at this site on an ongoing basis.
Hullin-Matsuda, Françoise; Tomishige, Nario; Sakai, Shota; Ishitsuka, Reiko; Ishii, Kumiko; Makino, Asami; Greimel, Peter; Abe, Mitsuhiro; Laviad, Elad L.; Lagarde, Michel; Vidal, Hubert; Saito, Tamio; Osada, Hiroyuki; Hanada, Kentaro; Futerman, Anthony H.; Kobayashi, Toshihide
2012-01-01
To identify novel inhibitors of sphingomyelin (SM) metabolism, a new and selective high throughput microscopy-based screening based on the toxicity of the SM-specific toxin, lysenin, was developed. Out of a library of 2011 natural compounds, the limonoid, 3-chloro-8β-hydroxycarapin-3,8-hemiacetal (CHC), rendered cells resistant to lysenin by decreasing cell surface SM. CHC treatment selectively inhibited the de novo biosynthesis of SM without affecting glycolipid and glycerophospholipid biosynthesis. Pretreatment with brefeldin A abolished the limonoid-induced inhibition of SM synthesis suggesting that the transport of ceramide (Cer) from the endoplasmic reticulum to the Golgi apparatus is affected. Unlike the Cer transporter (CERT) inhibitor HPA-12, CHC did not change the transport of a fluorescent short chain Cer analog to the Golgi apparatus or the formation of fluorescent and short chain SM from the corresponding Cer. Nevertheless, CHC inhibited the conversion of de novo synthesized Cer to SM. We show that CHC specifically inhibited the CERT-mediated extraction of Cer from the endoplasmic reticulum membranes in vitro. Subsequent biochemical screening of 21 limonoids revealed that some of them, such as 8β-hydroxycarapin-3,8-hemiacetal and gedunin, which exhibits anti-cancer activity, inhibited SM biosynthesis and CERT-mediated extraction of Cer from membranes. Model membrane studies suggest that 8β-hydroxycarapin-3,8-hemiacetal reduced the miscibility of Cer with membrane lipids and thus induced the formation of Cer-rich membrane domains. Our study shows that certain limonoids are novel inhibitors of SM biosynthesis and suggests that some biological activities of these limonoids are related to their effect on the ceramide metabolism. PMID:22605339
Kwon, Simona; Rideout, Catlin; Tseng, Winston; Islam, Nadia; Cook, Won Kim; Ro, Marguerite; Trinh-Shevrin, Chau
2012-01-01
Health promotion practice research conducted by or in partnership with community-based organizations (CBOs) serving Asian Americans, Native Hawaiians, and Pacific Islanders (AA and NHPI) can address health disparities. Few CBOs have the tools to integrate or initiate research into their programmatic agenda. The New York University (NYU) Center for the Study of Asian American Health (CSAAH) and the Asian & Pacific Islander American Health Forum (APIAHF) created a partnership with the goal to support CBO research infrastructure development by creating the Community Empowered Research Training (CERT) program. A survey was conducted and discussions held with CBO leaders representing AA and NHPI communities to inform the development of the CERT program. The majority of participants are engaged in service-related research and reported interest in building their research capacity. CBOs may require help reframing how data can be collected and used to better inform programmatic activities and to address health disparities facing AA and NHPI communities. CBOs possess both an interest in and access to local knowledge that can inform health priorities. Findings have been applied to the CERT program to build capacity to support community-initiated/driven research to address health disparities affecting AAs and NHPIs.
Software for Automated Testing of Mission-Control Displays
NASA Technical Reports Server (NTRS)
OHagan, Brian
2004-01-01
MCC Display Cert Tool is a set of software tools for automated testing of computerterminal displays in spacecraft mission-control centers, including those of the space shuttle and the International Space Station. This software makes it possible to perform tests that are more thorough, take less time, and are less likely to lead to erroneous results, relative to tests performed manually. This software enables comparison of two sets of displays to report command and telemetry differences, generates test scripts for verifying telemetry and commands, and generates a documentary record containing display information, including version and corrective-maintenance data. At the time of reporting the information for this article, work was continuing to add a capability for validation of display parameters against a reconfiguration file.
NASA Astrophysics Data System (ADS)
Kai, J. J.; Yu, G. P.; Tsai, C. H.; Liu, M. N.; Yao, S. C.
1989-10-01
A series of heat treatments were performed to study the sensitization and the stress corrosion cracking (SCC) behavior of INCONEL Alloy 690. The microstructural evaluation and the chromium depletion near grain boundaries were carefully studied using analytical electron microscopy (AEM). The measured chromium depletion profiles were matched well to the calculated results from a thermodynamic/kinetic model. The constant extension rate test (CERT) was performed in the solution containing 0.001 M sodium thiosulfate (Na2S2O3) to study the SCC resistance of this alloy. The Huey test was also performed in a boiling 65 pct HNO3 solution for 48 hours to study the intergranular attack (IGA) resistance of this alloy. Both tests showed that INCONEL 690 has very good corrosion resistance. It is believed that the superior IGA and SCC resistances of this alloy are due to the high chromium concentration (≈30 wt pct). It is concluded in this study that INCONEL 690 may be a better alloy than INCONEL 600 for use as the steam generator (S/G) tubing material for pressurized water reactors (PWR's)
Volatile organic compound analysis in wood combustion and meat cooking emissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zielinska, B.; McDonald, J.
1999-07-01
Residential wood combustion and meat cooking emissions were each analyzed for volatile organic compounds (VOC). Emissions were diluted 60--100 times, cooled to ambient temperature, and allowed 80 seconds for condensation prior to collection with the aid of a DRI-constructed dilution stack sampler. Fireplace and wood-stove emissions testing was conducted at the DRI facilities. Wood type, wood moisture, burn rate, and fuel load were varied for different experiments. Meat emissions testing was conducted at the CE-CERT stationary emissions lab, University of California, Riverside. Meat type, fat content, and cooking appliance were changed in different tests. VOCs were collected using stainless-steel 6more » L canisters and Tenax cartridges, whereas for carbonyl compound collection 2,4-dinitrophenylhydrazine (DNPH)-impregnated C{sub 18} SepPack cartridges were used. Analysis of VOC collected with canisters and Tenax cartridges was conducted by Gas Chromatography/Mass Spectrometry (GC/MS) and by GC/FID/ECD (flame ionization detection/electron capture detection). DNPH-impregnated cartridges were analyzed for fourteen C{sub 1}--C{sub 7} carbonyl compounds, using the HPLC method. The results of these measurements are discussed.« less
Haas, H; Mittelmeier, W
2014-06-01
EndoCert is an initiative of the Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie (DGOOC, German Society for Orthopedics and Orthopedic Surgery) which has been available since October 2012 and is the first system worldwide for certification of specialized arthroplasty centers. Before implementation of this certification concept two sequential pilot phases were carried out with representative treatment institutions. The results from these pilot clinics are presented with respect to quality improvement effects. Early effects on the quality of treatment have been achieved by rectification of nonconformities determined in the audit with respect to structural and process quality. A total of 172 nonconformities found in the 23 participating pilot clinics could be rectified. Long-term effects on the quality of results will in future be analyzed in cooperation with the German endoprosthesis register (EPRD) and by accompanying evaluations. A close feedback of the collated experiences and results to the certification committee, which is responsible for the procedure together with the DGOOC, allows continuous further development of the system EndoCert represents a substantial step towards a nationwide safety and improvement of the quality in arthroplasty treatment within the preoperative, perioperative and postoperative framework and can in future represent a decisive tool together with the EPRD in quality management.
Osmanski-Zenk, Katrin; Finze, Susanne; Lenz, Robert; Bader, Rainer; Mittelmeier, Wolfram
2018-06-26
The study aims to evaluate whether the postoperative outcome and the probability of complications of patients with total hip arthroplasty increases significantly when surgeons in training are in charge, assisted by a high volume surgeon, compared to a highly experienced orthopaedic surgeon, within the context of a high volume hospital certified to EndoCert. 192 patients with a primary hip arthroplasty were included. To assess the outcome, the Harris Hip Score, WOMAC, SF-36 and EuroQol-5D were surveyed pre- and 12 months postoperatively. As complications we considered the quality indicators defined by EndoCert. We found significant improvements in the postoperative score values with the qualifications of the surgeon in charge, even when a high volume surgeon or a surgeon in training was responsible. If a surgeon in training is assisted by a highly experienced surgeon, the risk of complications does not increase, although the operating time was significantly increased. Both the surgeon in training as well as the arthroplasty patient benefit from implementing the EndoCert system, because the postoperative outcome and the complication probability is independent of the qualifcation of the operating orthopaedic surgeon performing total hip arthroplasty when assisted by an experienced surgeon. Georg Thieme Verlag KG Stuttgart · New York.
1990-01-01
V’V for aqluatic organismls call be calclltteli wit Ii kmlowle’lle oIi 11151’ fatcto(rs. HIowI’ver , ai ke ,N un cert ainty remains in tile choice of...of the rapid rate of oxidation of Fe(II) at such pH and, possibly more importantly, the tendency of reduced iron to remain sorbed to particuiate iron...surface-located metal-organic complexes appears the most reasonable explanation for the ability of light to enhance colloid dissolution, much remains
BUILDING TRIBAL CAPABILITIES IN ENERGY RESOURCE TRIBES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mary Lopez
2003-04-01
The CERT Tribal Internship Program is part of the education and training opportunities provided by CERT to accelerate the development of American Indian technical professionals available to serve Tribes and expand the pool of these professionals. Tribes are severely impacted by the inadequate number of Indian professionals available to serve and facilitate Tribal participation and support of the energy future of Tribes,and subsequently the energy future of the nation. By providing interns with hands-on work experience in their field of study two goals are accomplished: (1) the intern is provided opportunities for professional enhancement; and (2) The pool of Indianmore » professionals available to meet the needs of Tribal government and Tribal communities in general is increased. As of January 17, 2003, Lance M Wyatt successfully completed his internship with the Interagency Working Group on Environmental Justice on the Task Force that specifically focuses their work on Tribal nations. While working as an intern with the National Transportation Program, Albuquerque operations, Jacqueline Agnew received an offer to work for the Alaska Native Health Board in Anchorage, Alaska. This was an opportunity that Ms. Agnew did not feel she could afford to forego and she left her internship position in February 2003. At present, CERT is in the process of finding another qualified individual to replace the internship position vacated by Ms. Agnew. Mr. Wyatt's and Ms. Agnew's final comments are given.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The purpose of the project was to: create a working relationship between CERT and Colorado State University (CSU); involve and create relationships among individuals and departments at CSU; empower Native communities to run their own affairs; establish programs for the benefit of Tribes; and create Native American Program Development Office at CSU. The intern lists the following as the project results: revised a Native American Program Development document; confirmation from 45 departments across campus for Summit attendance [Tribal Human Resource Development Summit]; created initial invitee list from CSU departments and colleges; and informed CERT and CSU staff of results. Muchmore » of the response from the campus community has been positive and enthusiastic. They are ready to develop new Native American programs on campus, but need the awareness of what they can do to be respectful of Tribal needs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Argonne National Laboratory's Summer Internship Program for American Indian & Native Alaska College Students. Supported by the Office of Indian Energy and Economic Development (IEED) in partnership with the Council of Energy Resource Tribes (CERT) and the U.S. Department of Energy.
NASA Astrophysics Data System (ADS)
Capell, Brent M.
2005-07-01
Selective internal oxidation (SIO) is a mechanism of grain boundary embrittlement through the formation of intergranular oxides of Cr2O3. SIO is proposed as a mechanism to explain intergranular stress corrosion cracking (IGSCC) of Ni-base alloys in pressurized water reactor environments. The purpose of this work is to investigate SIO through a series of experiments using controlled-purity alloys in a controlled, low-pressure steam environment in which the oxygen potential is varied. Five alloys; Ni-9Fe, Ni-5Cr, LCr (Ni-5Cr-9Fe), CD85 (Ni-16Cr-9Fe) and HCr (Ni-30Cr-9Fe), were used in corrosion coupon exposure tests and constant extension rate tensile (CERT) tests at 550°C and 400°C in an environment consisting of a controlled mixture of hydrogen, water vapor and argon. The hydrogen-to-water vapor partial pressure ratio (PPR) was varied between 0.001 and 0.9 to control the oxygen partial pressure. The Ni-9Fe, Ni-5Cr and LCr alloys formed a uniform Ni(OH)2 film at PPR values less than 0.09 while CD85 and HCr formed Cr2O 3 oxide films over the entire PPR range. Corrosion coupon results also show the formation of highly localized oxide particles at grain boundaries. Focused ion beam analysis revealed that intergranular oxides were observed at significant depths (>150 nm) down grain boundaries and the oxide morphology depended on the alloy composition and PPR value. Diffusion of oxygen along the grain boundary accounted for the growth of intergranular oxides. CERT test results showed that intergranular cracking was caused by creep-induced microvoid coalescence only at 550°C and did not depend on PPR. At 400°C, the cracking behavior depended on the PPR and resulted in a mixture of creep-induced microvoid coalescence and brittle intergranular failure. The cracked boundary fraction was higher at a PPR value where a Ni(OH)2 surface film formed. Alloy composition influenced cracking and the cracked boundary fraction decreased as the alloy chromium content increased. The compositions of oxides at intergranular crack tips were similar to intergranular oxides in corrosion coupons and demonstrated a link between intergranular oxide formation and intergranular cracking. The observation of intergranular oxides as well as the influence of alloy content on IG cracking was found to support SIO as a mechanism for IGSCC.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-22
... investigation resulting in-- (A) An affirmative determination of serious injury or threat thereof under section..., MN...... Inc., General Mills, Inc., Manpower, Certes, Salo, etc. The investigation revealed that the...
USGS National Assessment of Oil and Gas Online (NOGA Online)
Biewick, L.H.
2003-01-01
The Central Energy Resources Team (CERT) of the U.S. Geological Survey is providing results of the USGS National Assessment of Oil and Gas online (NOGA Online). In addition to providing resource estimates and geologic reports, NOGA Online includes an internet map application that allows interactive viewing and analysis of assessment data and results. CERT is in the process of reassessing domestic oil and natural gas resources in a series of priority basins in the United States using a Total Petroleum System (TPS) approach where the assessment unit is the basic appraisal unit (rather than the oil and gas play used in the 1995 study). Assessments of undiscovered oil and gas resources in five such priority provinces were recently completed to meet the requirements of the Energy Policy and Conservation Act of 2000 (EPCA 2000). New assessment results are made available at this site on an ongoing basis.
Ferderer, David A.
2001-01-01
Documented, reliable, and accessible data and information are essential building blocks supporting scientific research and applications that enhance society's knowledge base (fig. 1). The U.S. Geological Survey (USGS), a leading provider of science data, information, and knowledge, is uniquely positioned to integrate science and natural resource information to address societal needs. The USGS Central Energy Resources Team (USGS-CERT) provides critical information and knowledge on the quantity, quality, and distribution of the Nation's and the world's oil, gas, and coal resources. By using a life-cycle model, the USGS-CERT Data Management Project is developing an integrated data management system to (1) promote access to energy data and information, (2) increase data documentation, and (3) streamline product delivery to the public, scientists, and decision makers. The project incorporates web-based technology, data cataloging systems, data processing routines, and metadata documentation tools to improve data access, enhance data consistency, and increase office efficiency
Zanette, Sarah; Gao, Xiaoqing; Brunet, Megan; Bartlett, Marian Stewart; Lee, Kang
2016-10-01
The current study used computer vision technology to examine the nonverbal facial expressions of children (6-11years old) telling antisocial and prosocial lies. Children in the antisocial lying group completed a temptation resistance paradigm where they were asked not to peek at a gift being wrapped for them. All children peeked at the gift and subsequently lied about their behavior. Children in the prosocial lying group were given an undesirable gift and asked if they liked it. All children lied about liking the gift. Nonverbal behavior was analyzed using the Computer Expression Recognition Toolbox (CERT), which employs the Facial Action Coding System (FACS), to automatically code children's facial expressions while lying. Using CERT, children's facial expressions during antisocial and prosocial lying were accurately and reliably differentiated significantly above chance-level accuracy. The basic expressions of emotion that distinguished antisocial lies from prosocial lies were joy and contempt. Children expressed joy more in prosocial lying than in antisocial lying. Girls showed more joy and less contempt compared with boys when they told prosocial lies. Boys showed more contempt when they told prosocial lies than when they told antisocial lies. The key action units (AUs) that differentiate children's antisocial and prosocial lies are blink/eye closure, lip pucker, and lip raise on the right side. Together, these findings indicate that children's facial expressions differ while telling antisocial versus prosocial lies. The reliability of CERT in detecting such differences in facial expression suggests the viability of using computer vision technology in deception research. Copyright © 2016 Elsevier Inc. All rights reserved.
12 CFR 225.125 - Investment adviser activities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Court has upheld that determination. See Securities Industry Ass'n v. Board of Governors, 468 U.S. 207 (1984); see also Securities Industry Ass'n v. Board of Governors, 821 F.2d 810 (D.C. Cir. 1987), cert...
12 CFR 225.125 - Investment adviser activities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Court has upheld that determination. See Securities Industry Ass'n v. Board of Governors, 468 U.S. 207 (1984); see also Securities Industry Ass'n v. Board of Governors, 821 F.2d 810 (D.C. Cir. 1987), cert...
12 CFR 225.125 - Investment adviser activities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Court has upheld that determination. See Securities Industry Ass'n v. Board of Governors, 468 U.S. 207 (1984); see also Securities Industry Ass'n v. Board of Governors, 821 F.2d 810 (D.C. Cir. 1987), cert...
CERT Resilience Management Model, Version 1.0
2010-05-01
practice such as ISO 27000 , COBIT, or ITIL. If you are a member of an established process improvement community, particularly one centered on CMMI...Systems Audit and Control Association ISO International Organization for Standardization ISSA Information Systems Security Association IT
Indigenous Health Workforce Development: challenges and successes of the Vision 20:20 programme.
Curtis, Elana; Reid, Papaarangi
2013-01-01
There are significant health workforce inequities that exist internationally. The shortage of indigenous health professionals within Australia and New Zealand requires action across multiple sectors, including health and education. This article outlines the successes and challenges of the University of Auckland's Vision 20:20 programme, which aims to improve indigenous Māori and Pacific health workforce development via recruitment, bridging/foundation and tertiary retention support interventions within the Faculty of Medical and Health Sciences (FMHS). Seven years of student data (2005-2011) are presented for undergraduate Student Pass Rate (SPR) by ethnicity and Certificate in Health Sciences (CertHSc) SPR, enrolments and completions by ethnicity. Four key areas of development are described: (i) student selection and pathway planning; (ii) foundation programme refinement; (iii) academic/pastoral support; and (iv) re-development of the indigenous recruitment model. Key programme developments have had a positive impact on basic student data outcomes. The FMHS undergraduate SPR increased from 89% in 2005 to 94% in 2011 for Māori and from 81% in 2005 to 87% in 2011 for Pacific. The CertHSc SPR increased from 52% in 2005 to 92% in 2011 with a greater proportion of Māori and Pacific enrolments achieving completion over time (18-76% for Māori and 29-74% for Pacific). Tertiary institutions have the potential to make an important contribution to indigenous health workforce development. Key challenges remain including secondary school feeder issues, equity funding, programme evaluation, post-tertiary specialist workforce development and retention in Aotearoa, New Zealand. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.
INTERACTIVE WORKSHOP ON ARSENIC REMOVAL FROM DRINKING WATER
In 2005, EPA's Office of Water and Office of Research and Development collaborated to present eleven arsenic training events. The workshops provided in-depth treatment technology training to help those affected; state drinking water staff, design engineers, system owners and cert...
2014-01-23
was broken, the willow bent when it must and survived." Robert Jordan, The Fires of Heaven CERT I Software Engineering Institute I...transfer-of-wealth-in-history-7000000598/ 8. Caralli, Richard A.; Allen, Julia H.; White , David W. CERT® Resilience Management Model: A Maturity
Summer Internship Program for American Indian & Native Alaska College Students
None
2017-12-09
Argonne National Laboratory's Summer Internship Program for American Indian & Native Alaska College Students. Supported by the Office of Indian Energy and Economic Development (IEED) in partnership with the Council of Energy Resource Tribes (CERT) and the U.S. Department of Energy.
Bonn, Stephanie E; Alexandrou, Christina; Hjörleifsdottir Steiner, Kristin; Wiklander, Klara; Östenson, Claes-Göran; Löf, Marie; Trolle Lagerros, Ylva
2018-01-10
Physical activity can decrease the risk of complications related to diabetes type 2. Feasible and scalable strategies to implement support for a healthy lifestyle for patients in primary care are needed. The aim of the DiaCert-study is to evaluate a digital healthcare platform and the effect of a 12-week long smartphone-app physical activity intervention aiming at increasing physical activity (primary outcome) and improve levels of HbA1c (glycated hemoglobin), blood lipids, blood pressure, body composition, as well as other lifestyle factors and overall health in patients with diabetes type 2. The DiaCert-study is a two-arm, randomized controlled trial that will include 250 patients with diabetes type 2. At baseline, participants are randomized 1:1 to intervention, i.e. use of the smartphone-app, during 12 weeks, or to a control group receiving only standard care. Physical activity and sedentary behavior, is objectively measured using the Actigraph GT3X. Biomarkers including HbA1c and blood lipids are measured in fasting blood samples. Anthropometrics include height, weight, waist circumference and body composition, and a number of lifestyle factors including sleep, diet, self-efficacy, and quality of life, are assessed through an extensive questionnaire. Measurements are made at baseline and at follow-up after 3, 6 and 12 months. Using new technology, is one way to bridge the gap between what patients need and what health care can offer. This study evaluates a new digital health care platform and will show if use of a smartphone-app to promote daily steps is an effective and feasible method to increase physical activity and improve clinical markers in patients with diabetes type 2. ClinicalTrials.gov Identifier: NCT03053336 ; 7 Feb, 2017.
CERTS: Consortium for Electric Reliability Technology Solutions - Research Highlights
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eto, Joseph
2003-07-30
Historically, the U.S. electric power industry was vertically integrated, and utilities were responsible for system planning, operations, and reliability management. As the nation moves to a competitive market structure, these functions have been disaggregated, and no single entity is responsible for reliability management. As a result, new tools, technologies, systems, and management processes are needed to manage the reliability of the electricity grid. However, a number of simultaneous trends prevent electricity market participants from pursuing development of these reliability tools: utilities are preoccupied with restructuring their businesses, research funding has declined, and the formation of Independent System Operators (ISOs) andmore » Regional Transmission Organizations (RTOs) to operate the grid means that control of transmission assets is separate from ownership of these assets; at the same time, business uncertainty, and changing regulatory policies have created a climate in which needed investment for transmission infrastructure and tools for reliability management has dried up. To address the resulting emerging gaps in reliability R&D, CERTS has undertaken much-needed public interest research on reliability technologies for the electricity grid. CERTS' vision is to: (1) Transform the electricity grid into an intelligent network that can sense and respond automatically to changing flows of power and emerging problems; (2) Enhance reliability management through market mechanisms, including transparency of real-time information on the status of the grid; (3) Empower customers to manage their energy use and reliability needs in response to real-time market price signals; and (4) Seamlessly integrate distributed technologies--including those for generation, storage, controls, and communications--to support the reliability needs of both the grid and individual customers.« less
Chemical exchange rotation transfer (CERT) on human brain at 3 Tesla.
Lin, Eugene C; Li, Hua; Zu, Zhongliang; Louie, Elizabeth A; Lankford, Christopher L; Dortch, Richard D; Does, Mark D; Gore, John C; Gochberg, Daniel F
2018-05-25
To test the ability of a novel pulse sequence applied in vivo at 3 Tesla to separate the contributions to the water signal from amide proton transfer (APT) and relayed nuclear Overhauser enhancement (rNOE) from background direct water saturation and semisolid magnetization transfer (MT). The lack of such signal source isolation has confounded conventional chemical exchange saturation transfer (CEST) imaging. We quantified APT and rNOE signals using a chemical exchange rotation transfer (CERT) metric, MTR double . A range of duty cycles and average irradiation powers were applied, and results were compared with conventional CEST analyses using asymmetry (MTR asym ) and extrapolated magnetization transfer (EMR). Our results indicate that MTR double is more specific than MTR asym and, because it requires as few as 3 data points, is more rapid than methods requiring a complete Z-spectrum, such as EMR. In white matter, APT (1.5 ± 0.5%) and rNOE (2.1 ± 0.7%) were quantified by using MTR double with a 30% duty cycle and a 0.5-µT average power. In addition, our results suggest that MTR double is insensitive to B 0 inhomogeneity, further magnifying its speed advantage over CEST metrics that require a separate B 0 measurement. However, MTR double still has nontrivial sensitivity to B 1 inhomogeneities. We demonstrated that MTR double is an alternative metric to evaluate APT and rNOE, which is fast, robust to B 0 inhomogeneity, and easy to process. © 2018 International Society for Magnetic Resonance in Medicine.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-21
... purchased from the Commission's duplicating contractor, Best Copy and Printing, Inc. (BCPI), 445 12th Street.../ecfs/ . I. Background 1. In Council Tree Communications, Inc. v. FCC, 619 F.3d 235 (3d Cir. 2010), cert...
Summer Internship Program for American Indian and Native Alaska College Students
None
2017-12-11
Argonne National Laboratory's Summer Internship Program for American Indian & Native Alaska College Students. Supported by the Office of Indian Energy and Economic Development (IEED) in partnership with the Council of Energy Resource Tribes (CERT) and the U.S. Department of Energy.
Institutional Foundations for Cyber Security: Current Responses and New Challenges
2010-09-01
endowed with regional authority, they remain restricted in their capacity to respond to cyber criminals . National CERTs occupy a first-line responder role...economiccrime/ cybercrime/Documents/CountryProfiles/default_en.asp Federal Bureau of Investigation. (2006). Netting cyber criminals . Retrieved on February
Summer Internship Program for American Indian and Native Alaska College Students
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2010-01-01
Argonne National Laboratory's Summer Internship Program for American Indian & Native Alaska College Students. Supported by the Office of Indian Energy and Economic Development (IEED) in partnership with the Council of Energy Resource Tribes (CERT) and the U.S. Department of Energy.
Poluzzi, Elisabetta; Raschi, Emanuel; Motola, Domenico; Moretti, Ugo; De Ponti, Fabrizio
2010-04-01
Drug-induced torsades de pointes (TdP) is a complex regulatory and clinical problem due to the rarity of this sometimes fatal adverse event. In this context, the US FDA Adverse Event Reporting System (AERS) is an important source of information, which can be applied to the analysis of TdP liability of marketed drugs. To critically evaluate the risk of antimicrobial-induced TdP by detecting alert signals in the AERS, on the basis of both quantitative and qualitative analyses. Reports of TdP from January 2004 through December 2008 were retrieved from the public version of the AERS. The absolute number of cases and reporting odds ratio as a measure of disproportionality were evaluated for each antimicrobial drug (quantitative approach). A list of drugs with suspected TdP liability (provided by the Arizona Centre of Education and Research on Therapeutics [CERT]) was used as a reference to define signals. In a further analysis, to refine signal detection, we identified TdP cases without co-medications listed by Arizona CERT (qualitative approach). Over the 5-year period, 374 reports of TdP were retrieved: 28 antibacterials, 8 antifungals, 1 antileprosy and 26 antivirals were involved. Antimicrobials more frequently reported were levofloxacin (55) and moxifloxacin (37) among the antibacterials, fluconazole (47) and voriconazole (17) among the antifungals, and lamivudine (8) and nelfinavir (6) among the antivirals. A significant disproportionality was observed for 17 compounds, including several macrolides, fluoroquinolones, linezolid, triazole antifungals, caspofungin, indinavir and nelfinavir. With the qualitative approach, we identified the following additional drugs or fixed dose combinations, characterized by at least two TdP cases without co-medications listed by Arizona CERT: ceftriaxone, piperacillin/tazobactam, cotrimoxazole, metronidazole, ribavirin, lamivudine and lopinavir/ritonavir. Disproportionality for macrolides, fluoroquinolones and most of the azole antifungals should be viewed as 'expected' according to Arizona CERT list. By contrast, signals were generated by linezolid, caspofungin, posaconazole, indinavir and nelfinavir. Drugs detected only by the qualitative approach should be further investigated by increasing the sensitivity of the method, e.g. by searching also for the TdP surrogate marker, prolongation of the QT interval. The freely available version of the FDA AERS database represents an important source to detect signals of TdP. In particular, our analysis generated five signals among antimicrobials for which further investigations and active surveillance are warranted. These signals should be considered in evaluating the benefit-risk profile of these drugs.
75 FR 81632 - Australia Beef Imports Approved for the Electronic Certification System (eCERT)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-28
..., 2011, the export certification requirement for imports of beef from Australia subject to quantitative...: Background There are existing quantitative restraints on beef from Australia pursuant to U.S. Note 3... quantitative quota restrictions beginning January 3, 2011. Such imports that are entered, or withdrawn from...
What Happens after the Lease Is Signed?
ERIC Educational Resources Information Center
Richardson, Douglas
1980-01-01
The Council of Energy Resource Tribes (CERT) and 25 coal-owning tribes recently completed a study of issues associated with control and reclamation of surface mining. Article presents their seven recommendations for legislation enabling tribes to have greater control over the regulation and reclamation of strip mining on their lands. (Author/DS)
2014-08-01
IMPC. These threats may include natural and man-made disasters, damage, theft, fraud, and terrorism. Natural disasters such as hurricanes, earthquakes ...controls for mail sanctity include surveillance cameras, metal detectors , and X-ray screening to detect dangerous goods. (See IMT:SG2.SP1 and
29 CFR 4.187 - Recovery of underpayments.
Code of Federal Regulations, 2010 CFR
2010-07-01
...), cert. denied, 350 U.S. 902), and to give contracting agency reprocurement claims priority would be to.... United States, 132 Ct. Cl. 529 (1955), in which the courts gave priority to sureties who had paid unpaid..., PC-330, October 3, 1947; Reynolds Research Corp., Decision of the Administrator, PC-381, October 24...
Critical Homeland Infrastructure Protection
2007-01-01
talent. Examples include: * Detection of surveillance activities; * Stand-off detection of chemical, biological, nuclear, radiation and explosive ...Manager Guardian DARPA Overview Mr. Roger Gibbs DARPA LLNL Technologies in Support of Infrastructure Mr. Don Prosnitz LLNL Protection Sandia National...FP Antiterrorism/Force Protection CBRNE Chemical Biological Radiological Nuclear Explosive CERT Commuter Emergency Response Team CIA Central
SiLK: A Tool Suite for Unsampled Network Flow Analysis at Scale
2014-06-01
file format,” [Accessed: Feb 9, 2014]. [Online]. Available: https: //tools.netsa.cert.org/silk/faq.html#file-formats [12] “2012 data breach investigations...report (DBIR),” Verizon, Tech. Rep., 2012. [Online]. Available: http://www.verizonenterprise.com/DBIR/2012/ [13] “2013 data breach investigations
Natural Language Interface for Safety Certification of Safety-Critical Software
NASA Technical Reports Server (NTRS)
Denney, Ewen; Fischer, Bernd
2011-01-01
Model-based design and automated code generation are being used increasingly at NASA. The trend is to move beyond simulation and prototyping to actual flight code, particularly in the guidance, navigation, and control domain. However, there are substantial obstacles to more widespread adoption of code generators in such safety-critical domains. Since code generators are typically not qualified, there is no guarantee that their output is correct, and consequently the generated code still needs to be fully tested and certified. The AutoCert generator plug-in supports the certification of automatically generated code by formally verifying that the generated code is free of different safety violations, by constructing an independently verifiable certificate, and by explaining its analysis in a textual form suitable for code reviews.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vittal, Vijay; Lampis, Anna Rosa
The Power System Engineering Research Center (PSERC) engages in technological, market, and policy research for an efficient, secure, resilient, adaptable, and economic U.S. electric power system. PSERC, as a founding partner of the Consortium for Electric Reliability Technology Solutions (CERTS), conducted a multi-year program of research for U.S. Department of Energy (DOE) Office of Electricity Delivery and Energy Reliability (OE) to develop new methods, tools, and technologies to protect and enhance the reliability and efficiency of the U.S. electric power system as competitive electricity market structures evolve, and as the grid moves toward wide-scale use of decentralized generation (such asmore » renewable energy sources) and demand-response programs. Phase I of OE’s funding for PSERC, under cooperative agreement DE-FC26-09NT43321, started in fiscal year (FY) 2009 and ended in FY2013. It was administered by DOE’s National Energy Technology Laboratory (NETL) through a cooperative agreement with Arizona State University (ASU). ASU provided sub-awards to the participating PSERC universities. This document is PSERC’s final report to NETL on the activities for OE, conducted through CERTS, from September 2015 through September 2017 utilizing FY 2014 to FY 2015 funding under cooperative agreement DE-OE0000670. PSERC is a thirteen-university consortium with over 30 industry members. Since 1996, PSERC has been engaged in research and education efforts with the mission of “empowering minds to engineer the future electric energy system.” Its work is focused on achieving: • An efficient, secure, resilient, adaptable, and economic electric power infrastructure serving society • A new generation of educated technical professionals in electric power • Knowledgeable decision-makers on critical energy policy issues • Sustained, quality university programs in electric power engineering. PSERC core research is funded by industry, with a budget supporting approximately 30 principal investigators and some 70 graduate students and other researchers. Its researchers are multi-disciplinary, conducting research in three principal areas: power systems, power markets and policy, and transmission and distribution technologies. The research is collaborative; each project involves researchers typically at two universities working with industry advisors who have expressed interest in the project. Examples of topics for recent PSERC research projects include grid integration of renewables and energy storage, new tools for taking advantage of increased penetration of real-time system measurements, advanced system protection methods to maintain grid reliability, and risk and reliability assessment of increasingly complex cyber-enabled power systems. A PSERC’s objective is to proactively address the technical and policy challenges of U.S. electric power systems. To achieve this objective, PSERC works with CERTS to conduct technical research on advanced applications and investigate the design of fair and transparent electricity markets; these research topics align with CERTS research areas 1 and 2: Real-time Grid Reliability Management (Area 1), and Reliability and Markets (Area 2). The CERTS research areas overlap with the PSERC research stems: Power Systems, Power Markets, and Transmission and Distribution Technologies, as described on the PSERC website (see http://www.pserc.org/research/research_program.aspx). The performers were with Arizona State University (ASU), Cornell University (CU), University of California at Berkeley (UCB), and University of Illinois at Urbana-Champaign (UIUC). PSERC research activities in the area of reliability and markets focused on electric market and power policy analyses. The resulting studies suggest ways to frame best practices using organized markets for managing U.S. grid assets reliably and to identify highest priority areas for improvement. PSERC research activities in the area of advanced applications focused on mid- to long-term software research and development, with anticipated outcomes that move innovative ideas toward real-world application. Under the CERTS research area of Real-time Grid Reliability Management, PSERC has been focused on Advanced Applications Research and Development (AARD), a subgroup of activities that works to develop advanced applications and tools to more effectively operate the electricity delivery system, by enabling advanced analysis, visualization, monitoring and alarming, and decision support capabilities for grid operators.« less
Creep and intergranular cracking behavior of nickel-chromium-iron-carbon alloys in 360 C water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angeliu, T.M.; Paraventi, D.J.; Was, G.S.
1995-11-01
Mechanical testing of controlled-purity Ni-x% Cr-9% Fe-y% C alloys at 360 C revealed an environmental enhancement in intergranular (IG) cracking and time-dependent deformation in high-purity (HP) and primary water (PW) over that exhibited in argon. Dimples on the IG facets indicated a creep void nucleation and growth failure mode. IG cracking was located primarily in the interior of the specimen and was not necessarily linked to the environment. Controlled-potential constant extension rate tensile (CERT) experiments showed increases in IG cracking as the applied potential decreased, suggesting that hydrogen was detrimental to the mechanical properties. It was proposed that the environment,more » through the presence of hydrogen, enhanced IG cracking by enhancing the matrix dislocation mobility. This conclusion was based on observations that dislocation creep controlled IG cracking of controlled-purity Ni-x% Cr-9% Fe-y% C in argon at 360 C. Grain-boundary cavitation (GBC) and sliding (GBS) results showed environmental enhancement of the creep rate primarily resulted from an increase in matrix plastic deformation. However, controlled-potential constant load tensile (CLT) experiments did not indicate a change in the creep rate as the applied potential decreased. While this result did not support hydrogen-assisted creep, the material already may have been saturated with hydrogen at these applied potentials, and thus, no effect was realized. Chromium and carbon decreased IG cracking in HP and PW by increasing the creep resistance. The surface film did not play a significant role in the creep or IG cracking behavior under the conditions investigated.« less
Microbial control and food Preservation: Theory and practice:Principles of food preservation
USDA-ARS?s Scientific Manuscript database
Food preservation is an action or method used to maintain foods at certain desirable properties or quality to obtain maximum benefit. A good method of food preservation is one that slows down or prevents altogether the action of the agents of spoilage without damaging the food. To achieve this, cert...
78 FR 36548 - Filing Dates for the New Jersey Senate Special Elections
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-18
... Division, 999 E Street NW., Washington, DC 20463; Telephone: (202) 694- 1100; Toll Free (800) 424-9530... books for the applicable report(s). (See charts below for the closing date for each report.) Committees... Election Reg./cert. and Close of books overnight Filing Report \\1\\ mailing deadline deadline Quarterly...
Neighborhood organization activities: evacuation drills, clusters, and fire safety awareness
Dick White
1995-01-01
Emergency preparedness activities of one Berkeley-Oakland Hills neighborhood at the wildland/urban interface include establishing clusters that reduce fire hazards and fuel loads, setting aside emergency supplies, and identifying evacuation routes; taking emergency preparedness courses from the Offices of Emergency Services of Berkeley and Oakland (the CERT and CORE...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... treatment of multiple step plans for the acquisition of stock and CERTs involving members of a consolidated... language ``Service, 1111 Constitution Avenue NW.,'' is corrected to read ``Service, 1111 Constitution... from the bottom of the page, the language ``return group; (4) application of these'' is corrected to...
Vulnerability Discovery: Bridging the Gap Between Analysis and Engineering
2006-01-01
work in selected technologies © 2006 Carnegie Mellon University 16 An Easy Target: ActiveX 1995 – OLE 2 COM ActiveX 2000 – CERT/CC... ActiveX Security Workshop 2005 – VU#680526 New vector for exploiting COM vulnerabilities via Internet Explorer discovered 2006 – Dranzer, the COM Object
Production of synthetic fuels using syngas from a steam hydrogasification and reforming process
NASA Astrophysics Data System (ADS)
Raju, Arun Satheesh Kumar
This thesis is aimed at the research, optimization and development of a thermo-chemical process aimed at the production of synthesis gas (mixture of H2 and CO) with a flexible H2 to CO ratio using coupled steam hydrogasification and steam reforming processes. The steam hydrogasification step generates a product gas containing significant amounts of methane by gasifying a carbonaceous feed material with steam and internally generated H2. This product gas is converted to synthesis gas with an excess H2 to CO using the steam reformer. Research involving experimental and simulation work has been conducted on steam hydrogasification, steam reforming and the Fischer-Tropsch reaction. The Aspen Plus simulation tool has been used to develop a process model that can perform heat and mass balance calculations of the whole process using built-in reactor modules and an empirical FT model available in the literature. This model has been used to estimate optimum feed ratios and process conditions for specific feedstocks and products. Steam hydrogasification of coal and wood mixtures of varying coal to wood ratios has been performed in a stirred batch reactor. The carbon conversion of the feedstocks to gaseous products is around 60% at 700°C and 80% at 800°C. The coal to wood ratio of the feedstock does not exert a significant influence on the carbon conversion. The rates of formation of CO, CO 2 and CH4 during gasification have been calculated based on the experimental results using a simple kinetic model. Experimental research on steam reforming has been performed. It has been shown that temperature and the feed CO2/CH4 ratio play a dominant role in determining the product gas H2/CO ratio. Reforming of typical steam hydrogasification product-gas stream has been investigated over a commercial steam reforming catalyst. The results demonstrate that the combined use of steam hydrogasification process with a reformer can generate a synthesis gas with a predetermined H2/CO ratio from carbonaceous feedstocks. Experimental work on the Fischer-Tropsch synthesis has also been performed. A life cycle analysis has been performed with the objective of comparing the life cycle energy consumption and emissions of synthetic diesel fuel produced through the CE-CERT process with other fuel/vehicle combinations. The experimental and simulation results presented here demonstrate that the CE-CERT process is versatile and can potentially handle a number of different feedstocks. CE-CERT process appears to be suitable for commercialization in very large scales with a coal feedstock and also in a distributed network of smaller scale reactors utilizing localized renewable feedstocks.
NASA Astrophysics Data System (ADS)
Gupta, J.; Hure, J.; Tanguy, B.; Laffont, L.; Lafont, M.-C.; Andrieu, E.
2018-04-01
Irradiation Assisted Stress Corrosion Cracking (IASCC) is a complex phenomenon of degradation which can have a significant influence on maintenance time and cost of core internals of a Pressurized Water Reactor (PWR). Hence, it is an issue of concern, especially in the context of lifetime extension of PWRs. Proton irradiation is generally used as a representative alternative of neutron irradiation to improve the current understanding of the mechanisms involved in IASCC. This study assesses the possibility of using heavy ions irradiation to evaluate IASCC mechanisms by comparing the irradiation induced modifications (in microstructure and mechanical properties) and cracking susceptibility of SA 304 L after both type of irradiations: Fe irradiation at 450 °C and proton irradiation at 350 °C. Irradiation-induced defects are characterized and quantified along with nano-hardness measurements, showing a correlation between irradiation hardening and density of Frank loops that is well captured by Orowan's formula. Both irradiations (iron and proton) increase the susceptibility of SA 304 L to intergranular cracking on subjection to Constant Extension Rate Tensile tests (CERT) in simulated nominal PWR primary water environment at 340 °C. For these conditions, cracking susceptibility is found to be quantitatively similar for both irradiations, despite significant differences in hardening and degree of localization.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-21
... Fishers Lane, Rm. 1061, Rockville, MD 20852. FOR FURTHER INFORMATION CONTACT: Angela Krueger, Center for... 214 (D.C. Cir. 1985); Contact Lens Association v. FDA, 766 F.2d 592 (D.C. Cir.), cert. denied, 474 U.S... lymphedema) and/ or induration (e.g., stasis dermatitis) associated with chronic venous stasis; venous stasis...
2011-09-01
for Information Systems, National Communication Association, and cofounder and Chair of IFIP Working Group 8.6 on Diffusion , Transfer and...c;). -- -----• Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information ...the data needed, and completing and reviewing the collection of information . Send comments regarding this burden estimate or any other aspect of this
29 CFR 780.121 - What constitutes “raising” of livestock.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) includes such operations as the breeding, fattening, feeding, and general care of livestock. Thus... livestock is purchased to be fattened and is not bred on the premises does not characterize the fattening as.... 2d 626, cert. denied 311 U.S. 668; Walling v. Friend, 156 F. 2d 429). Employees of a cattle raisers...
29 CFR 780.121 - What constitutes “raising” of livestock.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) includes such operations as the breeding, fattening, feeding, and general care of livestock. Thus... livestock is purchased to be fattened and is not bred on the premises does not characterize the fattening as.... 2d 626, cert. denied 311 U.S. 668; Walling v. Friend, 156 F. 2d 429). Employees of a cattle raisers...
29 CFR 780.121 - What constitutes “raising” of livestock.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) includes such operations as the breeding, fattening, feeding, and general care of livestock. Thus... livestock is purchased to be fattened and is not bred on the premises does not characterize the fattening as.... 2d 626, cert. denied 311 U.S. 668; Walling v. Friend, 156 F. 2d 429). Employees of a cattle raisers...
By, With, and Through: The Theory and Practice of Special Operations Capacity-Building
2014-12-01
The Colombian Military..........................................................94 3. SOCSOUTH ON THE GROUND IN COLOMBIA .......................95...civil affairs operations CCOPE Colombian Joint Special Operations Command (Comando Conjunto de Operaciones Especiales) CERTE Colombian Army...Tactical Retraining Center CF Conventional forces CMO civil-military operations CMSE civil-military support element CNP Colombian National Police CNT
29 CFR 779.356 - Application of exemptions to employees.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Establishments Lumber and Building Materials Dealers § 779.356 Application of exemptions to employees. (a... materials qualifies as an exempt retail or service establishment under section 13(a)(2) or as an exempt... establishments (§ 779.310; McComb v. W. E. Wright Co., 168 F. 2d 40, cert. denied 335 U.S. 854). Neither...
29 CFR 779.356 - Application of exemptions to employees.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Establishments Lumber and Building Materials Dealers § 779.356 Application of exemptions to employees. (a... materials qualifies as an exempt retail or service establishment under section 13(a)(2) or as an exempt... establishments (§ 779.310; McComb v. W. E. Wright Co., 168 F. 2d 40, cert. denied 335 U.S. 854). Neither...
29 CFR 779.356 - Application of exemptions to employees.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Establishments Lumber and Building Materials Dealers § 779.356 Application of exemptions to employees. (a... materials qualifies as an exempt retail or service establishment under section 13(a)(2) or as an exempt... establishments (§ 779.310; McComb v. W. E. Wright Co., 168 F. 2d 40, cert. denied 335 U.S. 854). Neither...
29 CFR 779.356 - Application of exemptions to employees.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Establishments Lumber and Building Materials Dealers § 779.356 Application of exemptions to employees. (a... materials qualifies as an exempt retail or service establishment under section 13(a)(2) or as an exempt... establishments (§ 779.310; McComb v. W. E. Wright Co., 168 F. 2d 40, cert. denied 335 U.S. 854). Neither...
29 CFR 779.356 - Application of exemptions to employees.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Establishments Lumber and Building Materials Dealers § 779.356 Application of exemptions to employees. (a... materials qualifies as an exempt retail or service establishment under section 13(a)(2) or as an exempt... establishments (§ 779.310; McComb v. W. E. Wright Co., 168 F. 2d 40, cert. denied 335 U.S. 854). Neither...
Initial Teacher Training Courses and Non-Native Speaker Teachers
ERIC Educational Resources Information Center
Anderson, Jason
2016-01-01
This article reports on a study contrasting 41 native speakers (NSs) and 38 non-native speakers (NNSs) of English from two short initial teacher training courses, the Cambridge Certificate in English Language Teaching to Adults and the Trinity College London CertTESOL. After a brief history and literature review, I present findings on teachers'…
CERT Resiliency Engineering Framework
2007-03-01
Heightened threat level and increasing uncertainty Shorter-lived skills 5 Operational risk management problems Poor planning and execution No asset...increasingly effective & efficient Today’s operational environment No operational boundaries Pervasive & rapidly changing technology Dynamic & expanding risks ...management function Seen as a technical function or responsibility Searching for magic bullet: CobiT , ITIL, ISO17799, NFP1600 Poorly defined and measured
Setting Up a Grid-CERT: Experiences of an Academic CSIRT
ERIC Educational Resources Information Center
Moller, Klaus
2007-01-01
Purpose: Grid computing has often been heralded as the next logical step after the worldwide web. Users of grids can access dynamic resources such as computer storage and use the computing resources of computers under the umbrella of a virtual organisation. Although grid computing is often compared to the worldwide web, it is vastly more complex…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-24
... Commission has considered the proposed rule's impact on efficiency, competition, and capital formation. See... security.''). See also Newton v. Merrill, Lynch, Pierce, Fenner & Smith, Inc., 135 F.3d 266, at 271, 274 (3d Cir.), cert. denied, 525 U.S. 811 (1998); Payment for Order Flow, Securities Exchange Act Release...
CERT Resilience Management Model: A Maturity Model Approach to Managing Operational Resilience
2010-07-28
manufacturing, and energy 8 years @ SEI concentrating in information security risk management BS-Accounting; MBA Frequent lecturer in Carnegie...impact Move all operational risk management activities in the same direction Optimize cost/effectiveness Meet mission no-matter-what How do you...processes Effective operational risk management requires harmonization: convergence of these activities working toward the same goals Operational
ABCs of Operational Resilience
2014-01-23
Mission Success To be operationally resilient, cyber- and/or kinetic-enabled missions must address operational risk on a number of “planes...man ement, protection, and s stainme t begin. CERT® Operational Resilience: Manage, Protect, and Sustain Twitter #CERTopRES © 2014 Carnegie... t c e t ee Lo e CERT I Software Engineering Institute I CarnegieMellonUniversity CERT® Operational Resilience: Manage, Protect, and Sustain
2010-09-01
Operations and Procedures • Logistics and Facilities • Training • Exercises, Evaluation and Corrective Actions • Crisis Communications ...Assessment Team BCA Benefit-cost analysis CEO Chief Executive Officer CERT Community Emergency Response Team CFR Code of Federal Regulations...CHDS Center for Homeland Defense and Security CPG 101 Comprehensive Preparedness Guidelines 101 CPP Community Preparedness and Participation CPW
The Decline and Fall of Joint Acquisition Programs
2014-04-30
S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Studies have...Massachusetts Institute of Technology Ed Crawley, Massachusetts Institute of Technology Acquisition Risks in a World of Joint Capabilities: A Study of...University and a graduate assistant in the CERT Insider Threat Center. In addition to information security, Collins has focused his graduate studies
Government Procurement. Crimes and Offenses (Thesis I of a Two-Thesis Project)
1983-08-01
Borelli , 336 F.2d 376, 384 (2d Cir. 1964), cert.denied, 379 U.S. 960 (1965): The basic difficulty arises in applying the seven- teenth century notion...549, at 367-70; United States v. Kissel, supra note 460, at 608; United States v. Borelli , supra note 461, at 388-90; United States v. Stromberg, 268
Cruz, Antonio M; Barr, Cameron; Puñales-Pozo, Elsa
2008-01-01
This research's main goals were to build a predictor for a turnaround time (TAT) indicator for estimating its values and use a numerical clustering technique for finding possible causes of undesirable TAT values. The following stages were used: domain understanding, data characterisation and sample reduction and insight characterisation. Building the TAT indicator multiple linear regression predictor and clustering techniques were used for improving corrective maintenance task efficiency in a clinical engineering department (CED). The indicator being studied was turnaround time (TAT). Multiple linear regression was used for building a predictive TAT value model. The variables contributing to such model were clinical engineering department response time (CE(rt), 0.415 positive coefficient), stock service response time (Stock(rt), 0.734 positive coefficient), priority level (0.21 positive coefficient) and service time (0.06 positive coefficient). The regression process showed heavy reliance on Stock(rt), CE(rt) and priority, in that order. Clustering techniques revealed the main causes of high TAT values. This examination has provided a means for analysing current technical service quality and effectiveness. In doing so, it has demonstrated a process for identifying areas and methods of improvement and a model against which to analyse these methods' effectiveness.
Chlamydiae interaction with the endoplasmic reticulum: contact, function and consequences.
Derré, Isabelle
2015-07-01
Chlamydiae and chlamydiae-related organisms are obligate intracellular bacterial pathogens. They reside in a membrane-bound compartment termed the inclusion and have evolved sophisticated mechanisms to interact with cellular organelles. This review focuses on the nature, the function(s) and the consequences of chlamydiae-inclusion interaction with the endoplasmic reticulum (ER). The inclusion membrane establishes very close contact with the ER at specific sites termed ER-inclusion membrane contact sites (MCSs). These MCSs are constituted of a specific set of factors, including the C. trachomatis effector protein IncD and the host cell proteins CERT and VAPA/B. Because CERT and VAPA/B have a demonstrated role in the non-vesicular trafficking of lipids between the ER and the Golgi, it was proposed that Chlamydia establish MCSs with the ER to acquire host lipids. However, the recruitment of additional factors to ER-inclusion MCSs, such as the ER calcium sensor STIM1, may suggest additional functions unrelated to lipid acquisition. Finally, chlamydiae interaction with the ER appears to induce the ER stress response, but this response is quickly dampened by chlamydiae to promote host cell survival. © 2015 John Wiley & Sons Ltd.
Efficient Transmission of DoD PKI Certificates in Tactical Networks
2010-01-01
011 the COlll- mand line. To extract individual fields from cert ifica tes, we used the X.509 subset of the C API included with OpenSSL (vl.O.0-bcta2...www.disa.mil/nces. [17J NSA Suite Il Cryptogt"aphy. http://vvv . nsa.gov/ial programs/suiteb_cryptography/index.shtml. [18J OpenSSL : The Open Source toolk
2017-03-01
has developed multiple programs addressing community engagement,2 and these have often focused on small groups within law enforcement organizations... groups or a “one-size-fits-all” approach to community outreach, the cultural intelligence model focuses on developing the cultural competency of the...Response Teams (CERT). These community engagement programs offer a limited approach to developing relationships with community groups and
2007-05-01
business processes and services. 4. Security operations management addresses the day-to-day activities that the organization performs to protect the...Management TM – Technology Management Security Operations Management SOM – Security Operations Management 5.7.2 Important Operations Competency...deals with the provision of access rights to informa- tion and technical assets SOM – Security Operations Management , which addresses the fundamental
Manual for Courts-Martial, United States, 1984. Revision.
1984-01-01
301(d); 301a(c). See also S. Rep. No. 544. 89th Cong., Ist Sess. 13 (1965) which equates "all out war" to a declared war. The legislative history... Hammett v. Texas, 448 U.S. 725 )1974): Shellmun v. U.S. Lines, Inc.. 528 F. 2d 675 (9th Cir. 1975), cert. denied, 425 U.S. 936 (1976). Subsection (41 is
Learning From Errors in Ambulatory Pediatrics
2005-01-01
355 Learning from Errors in Ambulatory Pediatrics Julie J. Mohr, Carole M. Lannon, Kathleen A. Thoma, Donna Woods, Eric J. Slora, Richard C...for Healthcare Research and Quality (AHRQ) as part of the University of North Carolina (UNC) Center for Education and Research on Therapeutics...CERTs), in partnership with the American Academy of Pediatrics (AAP) Pediatric Research in Office Settings (PROS) Network. Purpose: Learning from Errors
Report of the Defense Science Board Task Force on Critical Homeland Infrastructure Protection
2007-01-01
nuclear, radiation and explosive hazards; • Monitoring “people of interest” while protecting civil liberties; • Detection of hostile intent; • Detect...Guardian DARPA Overview Mr. Roger Gibbs DARPA LLNL Technologies in Support of Infrastructure Protection Mr. Don Prosnitz LLNL Sandia National...Mechanical Engineers AT/FP Antiterrorism/Force Protection CBRNE Chemical Biological Radiological Nuclear Explosive CERT Commuter Emergency Response Team
2013-08-08
theft in the CERT Insider Threat Database were associated with foreign social network connections. 1 Verizon. “The 2013 Data Breach Investigations...passwords, opening infected attachments or web sites, etc. 1 Verizon. “The 2013 Data Breach Investigations Report.” http...were experienced by 38% of respondents1 • The 2013 Verizon Data Breach Report2 reveals • 29% of breaches studied leveraged social tactics • A
The creep and intergranular cracking behavior of Ni-Cr-Fe-C alloys in 360{degree}C water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angeliu, T.M.; Paraventi, D.J.; Was, G.S.
1995-09-01
Mechanical testing of controlled-purity Ni-xCr-9Fe-yC alloys at 360 C revealed an environmental enhancement in IG cracking and time-dependent deformation in high purity and primary water over that exhibited in argon. Dimples on the IG facets indicate a creep void nucleation and growth failure mode. IG cracking was primarily located at the interior of the specimen and not necessarily linked to direct contact with the environment. Controlled potential CERT experiments showed increases in IG cracking as the applied potential decreased, suggesting that hydrogen is detrimental to the mechanical properties. It is proposed that the environment, through the presence of hydrogen, enhancesmore » IG cracking by enhancing the matrix dislocation mobility. This is based on observations that dislocation-controlled creep controls the IG cracking of controlled-purity Ni-xCr-9Fe-yC in argon at 360 C and grain boundary cavitation and sliding results that show the environmental enhancement of the creep rate is primarily due to an increase in matrix plastic deformation. However, controlled potential CLT experiments did not exhibit a change in the creep rate as the applied potential decreased. While this does not clearly support hydrogen assisted creep, the material may already be saturated with hydrogen at these applied potentials and thus no effect was realized. Chromium and carbon decrease the IG cracking in high purity and primary water by increasing the creep resistance. The surface film does not play a significant role in the creep or IG cracking behavior under the conditions investigated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, D.T.
1995-10-01
A corrosion investigation was conducted to determine corrosion behavior and stress corrosion cracking (SCC) susceptibility of S30400 and S31600 stainless steel exposed to soldering flux paste containing 25 wt% zinc chloride. Electrochemical test results indicated that soldering flux paste was not corrosive to S30400 and S31600 at room temperature. The wax phase (light phase) of soldering flux was also not corrosive to S30400 and S31600. However, the heavy phase of solder flux was corrosive to S30400 and S31600 at elevated temperatures. In heavy phase, S30400 did not passivate, while S31600 passivated at temperatures up to 80 C while no passivitymore » was observed at 85 C and above. AC impedance test results showed that S30400 and S31600 corroded at rates of less than 0.1 mpy in solder flux pastes at room temperature. In the soldering flux heavy phase, corrosion rates were about 2 mpy or less for S30400 at temperatures up to 75 C and S31600 at temperatures up to 70 C. However, corrosion rates of S30400 in the soldering flux heavy phase increased to 5, 8, 10, and 22 mpy at 80, 85, 90, and 95 C while corrosion rates of S31600 sst in the soldering flux heavy phase increased to 4, 5, 7, and 11, and 30 mpy at 75, 80, 85, 90 and 95 C, respectively. CERT results revealed that no SCC susceptibility when S30400 and S31600 were exposed to soldering flux paste at room temperature and wax phase at 65 and 95 C. However, both test alloys were susceptible to transgranular SCC when exposed to the soldering flux heavy phase at temperatures of 65+ C. Severity of SCC increased with temperature increase. SCC fractures were characterized by reduction of ductility and numerous SCC secondary cracks on the specimen gage length. The most severe SCC fracture was observed on a S30400 specimen partially submersed in the soldering flux heavy phase and partially submersed in the soldering flux wax phase at 95 C. No similar cracking was observed on S31600.« less
Evaluation of the Susceptibility to SCC Initiation of Alloy 690 in Simulated PWR Primary Water
NASA Astrophysics Data System (ADS)
Tsutsumi, Kazuya; Couvant, Thierry
Alloy 690 has been widely used in fabricating components of LWR plants as an alternative material to Alloy 600 which has exhibited a significant susceptibility to PWSCC. However, some authors have reported that Alloy 690 can suffer a significant susceptibility to SCC crack growth when highly cold worked. While most of the recent studies emphasize SCC propagation phase, EDF and its partners are focusing on the material's resistance to SCC initiation. This paper summarizes the current work carried out at EDF MAI on the SCC initiation. By means of constant elongation rate tests (CERTs) and constant displacement tests, experimental investigation of the susceptibility to PWSCC were performed. No SCC was observed on either an extruded bar or on two plates, even after 24%-1D cold rolling, confirming the superior PWSCC resistance of Alloy 690 independent of a amount of intergranular precipitation of carbides, and also revealing that such cold rolling does not necessarily decrease the resistance to SCC. On the other hand, a experimental steam generator tube that has a degraded microstructure due to specific heat-treatment revealed its susceptibility to SCC, probably because of the interactive effect of microstructure with heavy intragranular carbide precipitations and the cold worked superficial layer. This phenomenon is in good agreement with results previously published. In this study, the maximal crack depth slightly increased when DH increased from 5 to 60 cc.kg-1H2O. No significant prior ageing effect on the crack depth was observed, even when ageing was combined with high DH.
Improving the Automated Detection and Analysis of Secure Coding Violations
2014-06-01
eliminating software vulnerabilities and other flaws. The CERT Division produces books and courses that foster a security mindset in developers, and...website also provides a virtual machine containing a complete build of the Rosecheckers project on Linux . The Rosecheckers project leverages the...Compass/ROSE6 project developed at Law- rence Livermore National Laboratory. This project provides a high-level API for accessing the abstract syntax tree
Software Engineering Institute: Year in Review 2008
2008-01-01
security information they need. Now, new podcasts are uploaded every two weeks to the CERT website and iTunes . The series has become increasingly...reused throughout an organization— customer lookup, account lookup, and credit card validation are some examples. 2008 YEAR IN REVIEW...were charged in August 2008 with the theft of more than 40 million credit and debit card numbers from T.J. Maxx, Marshall’s, Barnes & Noble
Insider Threat Study: Illicit Cyber Activity in the Banking and Finance Sector
2005-06-01
as a computer fraud case investigated by the Secret Service. Each case was analyzed from a behavioral and a technical perspective to identify...insider threat and address the issue from an approach that draws on human resources, corporate security, and information security perspectives. The ... Secret Service National Threat Assessment Center and the CERT Coordination Center of Carnegie Mellon University’s Software Engineering Institute joined
The CERT Guide to Coordinated Vulnerability Disclosure
2017-08-11
Incident vs. Vulnerability Response 6 1.3 Why Coordinate Vulnerability Disclosures? 6 1.4 Previewing the Remainder of this Document 7 2 Principles of...Accidental Leaks 53 6.5 Independent Discovery 54 6.6 Active Exploitation 55 6.7 Relationships that Go Sideways 55 6.8 Hype, Marketing , and...guide provides an introduction to the key concepts, principles , and roles necessary to establish a successful CVD process. It also provides insights
Low Cost Technical Solutions to Jump Start an Insider Threat Program
2016-05-11
Low Cost Technical Solutions to Jump Start an Insider Threat Program George J. Silowash Derrick L. Spooner Daniel L. Costa Michael J...Albrethsen May 2016 TECHNICAL NOTE CMU/SEI-2016-TN-004 CERT Division http://www.sei.cmu.edu Copyright 2016 Carnegie Mellon University This... technical note will explore tools that may be suitable for satisfying the basic technical needs of an insider threat program, giving organizations a
Combating the Insider Cyber Threat
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greitzer, Frank L.; Moore, Andrew P.; Cappelli, Dawn M.
This article represents a collaboration between PNNL, CERT/CMU, and AFRL that describes needs and related efforts by these institutions to develop technologies and approaches to counter cyber threats by insiders to informatin systems. The main focus of this article is on the need for effective training on insider threat to raise staff awareness and encourage organizations to adopt a more effective approach to identifying potential risks and take proactive steps to mitigate them.
CERT Research Annual Report 2009
2009-01-01
Domain Name System (DNS), which maps names to IP addresses, is a vital component of the Internet. Nearly every transaction on the Internet begins by...many different ASNs (Autonomous System Numbers, which map to Internet Service Providers) there are. If there are more than 20, then it is extremely...functions, that is, mappings from their domains to ranges, or inputs to outputs. These mappings are pre-defined as a starting point for the FX
Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy
2012-03-01
for the consumer at the mo- ment but will soon become a commoditized, basic requirement. For example, as the baby boomers grow older, mobile services...Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy The WEA Project Team March 2012 SPECIAL REPORT CMU/SEI-2012-TR-019 CERT...report presents a taxonomy developed for the Commercial Mobile Alert Service (CMAS). The CMAS Alerting Pipeline Taxonomy is a hierarchical classification
Blacklist Ecosystem Analysis Update: 2014
2014-12-01
example, we checked to see if any of the blacklisted IP addresses were known sinkhole IP addresses. This information would essentially invalidate the...indicator as an indicator of malicious activity, since sinkholes are operated by CERTCC-2014-82 4 Blacklist Ecosystem Analysis CERT/CC network defenders who...clean up and collect intelligence on threats. Only one list out of 67, LI_3, contained any sinkhole IP addresses and that list contained only 10. All
High Frontier, The Journal for Space & Missile Professionals. Volume 5, Number 3
2009-05-01
assume cyberspace responsibilities as directed by CORONA Fall. General Kehler has commanded at the squadron, group, and twice at the wing level, and has...October 2008 CORONA conference, the Air Force Space Command (AFSPC), in con- cert with Air Force Cyberspace Command (Provisional), is working diligently...which include electronic jamming equipment, computer viruses , directed-energy weapons, laser beam weapons, and non-directed-energy weapons
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-28
... DEPARTMENT OF LABOR Employment and Training Administration Electronic Filing of H-2A and H-2B... certification applications under the H-2A and H-2B visa programs through the Department of Labor's (Department... will be able to submit H-2B applications electronically beginning on October 15, 2012, and H-2A...
Perception of studying dental law and ethics among postgraduate dental students in the UK.
Wassif, H S
2015-08-14
Law and ethics is an integral part of medical and dental professional practice. The subject is touched upon in the undergraduate curriculum. Historically, dentists interested in postgraduate study in this subject have accessed courses on medical law and ethics. While there are areas of shared interest (for example, consent, confidentiality) there are differences in emphasis and content (for example, end of life care, organ transplants, etc) which are not relevant to dentistry. A new postgraduate certificate (PgCert) course was approved by the University of Bedfordshire designed specifically for dental practitioners, making it the only university accredited course in the UK that is specific to dental staff. Students' perception of the subject of dental law and ethics at a postgraduate level was not known. The first PgCert student cohort was assessed at the start and the end of the course using two questionnaires. Sixteen students, all qualified dental practitioners working in the UK, took part. The perception toward the subject of dental law and ethics was in-line with the current guideline and regulations governing the dental profession. Perception of dental law was clearer at the end of the course compared to the beginning while dental ethics remained a challenging subject.
2011-09-01
concert with a physical attack. Additionally, the importance of preventive measures implemented by a social human network to counteract a cyber attack...integrity of the data stored on specific computers. This coordinated cyber attack would have been successful if not for the trusted social network...established by Mr. Hillar Aarelaid, head of the Estonian computer 6 emergency response team (CERT). This social network consisted of Mr. Hillar Aarelaid
Making DidFail Succeed: Enhancing the CERT Static Taint Analyzer for Android App Sets
2015-03-01
privileged task for an application without permissions. The Epicc [3] tool precisely analyzes inter-app communication in Android . By looking at intents...security. By placing adjustable limitations on what resources applications can use, Android allows users a large degree of control over how much trust...the user’s location, contacts, and other personal details. One of the core assumptions of the Android permission system is that an application that
Making DidFail Succeed: Enhancing the CERT Static Taint Analyzer for Android App Sets
2015-03-31
privileged task for an application without permissions. The Epicc [3] tool precisely analyzes inter-app communication in Android . By looking at intents...security. By placing adjustable limitations on what resources applications can use, Android allows users a large degree of control over how much trust...the user’s location, contacts, and other personal details. One of the core assumptions of the Android permission system is that an application that
CERT tribal internship program. Final intern report: Melinda Jacquez, 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
The purpose of the intern project was to write a comprehensive booklet on all state legislation proposed in 1995 on Native American issues. A second purpose was to contact tribal governments and request an ordinance, law or resolution on hazardous and nuclear waste transportation. This intern report contains a summary of bills proposed in 37 state legislatures pertaining to Native American issues. Time ran out before the second project objective could be met.
Estimation of AFEES (Armed Forces Entrance Examination Stations) Survey Weights.
1984-01-01
DISTRIBUTION OF POPULATION CHARACTERISTICS IN SPRING WAVE % Unweighted % Weighted % Population Characteristic Survey Survey Eligible Education Level HS...4’ - 22 - Table 10 EFFECT OF WEIGHTING ON ESTIMATED DISTRIBUTION OF POPULATION CHARACTERISTICS IN FALL WAVE % Unweighted % Weighted % Population ... Characteristic Survey Survey Eligible Education Level HS grad or beyond 64.6 59.9 54.4 Cert of gen educ develop 7.4 6.4 4.9 Not HS grad 27.9 33.6 40.5
Source Code Analysis Laboratory (SCALe) for Energy Delivery Systems
2010-12-01
the software for reevaluation. Once the ree- valuation process is completed, CERT provides the client a report detailing the software’s con - formance...Flagged Nonconformities (FNC) Software System TP/FNC Ratio Mozilla Firefox version 2.0 6/12 50% Linux kernel version 2.6.15 10/126 8% Wine...inappropriately tuned for analysis of the Linux kernel, which has anomalous results. Customizing SCALe to work with energy system software will help
An Analysis of Security Incidents on the Internet 1989-1995
1997-04-07
DeHart, Derek Simmel, and James Stevens. Thanks to the Engineering and Public Policy Department for their support, both intellectually and financially...stated in Chapter 4, the first of these categories, the judgment of CERT@/CC personnel, was given sa- ong weight in determining the scope of an...Coh95] [DSB96] [FIR961 [Fri78] References Derek Atkins, Paul Buis, Chris Hare, Robert Kelley, Carey Nachenberg Anthony B. Nelson, Paul Phillips, Tim
Report from the First CERT-RMM Users Group Workshop Series
2012-04-01
deploy processes to support our programs – Benchmark our programs to determine current gaps – Complements current work in CMMI® and ISO 27001 19...benchmarking program performance through process analytics and Lean/Six Sigma activities to ensure Performance Excellence. • Provides ISO Standards...Office www.cmu.edu/ iso 29 Carnegie Mellon University • Est 1967 in Pittsburgh, PA • Global, private research university • Ranked 22nd • 15,000
Successful Hazwaste Program Halts Annual State Inspection
2011-05-01
ES) Red River Army Depot ,100 James Carlow Drive, Texarkana ,TX,75507-5000 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY...MAIN DRIVE. TEXARKANA . lX 75507 ~5000103 334~3333 Accumulation Start Date ** Cert1fied F1ll Date. WC$0oocr- IIFiol ----= CUSTOMIZE YOUR OWN...MARKING/LABELING TO COMPLY BE AMERICA’S BEST Con tamer: *RRA0023678* RRAD023678 Hazardous Waste RED RIVER ARMY DEPOT 100 MAIN DRIVE TEXARKANA , 1X
Verified Separate Compilation for C
2015-06-01
simulations, says that the visible set is closed under reachability. These two conditions, plus (6.2) and monotonicity of the REACH relation, imply...erase to a CompCert memory m. By erasure, we mean the removal of the “ juice ” that is unnecessary for execution (as in Curry-style type erasure of...simply typed lambda calculus). The “ juice ” has several components: permission shares controlling access to objects in the program logic; predicates in the
Survivability of Autonomous Microgrid during Overload Events
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Wei; Lasseter, Robert H.; Khalsa, Amrit S.
Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources’ frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sourcesmore » in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Lastly, simulation and field tests from CERTS/AEP microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter & generator mixed microgrids.« less
Survivability of Autonomous Microgrid during Overload Events
Du, Wei; Lasseter, Robert H.; Khalsa, Amrit S.
2018-04-23
Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources’ frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sourcesmore » in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Lastly, simulation and field tests from CERTS/AEP microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter & generator mixed microgrids.« less
NASA Astrophysics Data System (ADS)
Zeitz, Christian; Scheidat, Tobias; Dittmann, Jana; Vielhauer, Claus; González Agulla, Elisardo; Otero Muras, Enrique; García Mateo, Carmen; Alba Castro, José L.
2008-02-01
Beside the optimization of biometric error rates the overall security system performance in respect to intentional security attacks plays an important role for biometric enabled authentication schemes. As traditionally most user authentication schemes are knowledge and/or possession based, firstly in this paper we present a methodology for a security analysis of Internet-based biometric authentication systems by enhancing known methodologies such as the CERT attack-taxonomy with a more detailed view on the OSI-Model. Secondly as proof of concept, the guidelines extracted from this methodology are strictly applied to an open source Internet-based biometric authentication system (BioWebAuth). As case studies, two exemplary attacks, based on the found security leaks, are investigated and the attack performance is presented to show that during the biometric authentication schemes beside biometric error performance tuning also security issues need to be addressed. Finally, some design recommendations are given in order to ensure a minimum security level.
Making DidFail Succeed: Enhancing the CERT Static Taint Analyzer for Android App Sets
2015-03-01
limitations on what resources applications can use, Android allows users a large degree of control over how much trust should be given to specific...and other personal details. One of the core assumptions of the Android permission system is that an application that lacks permission to access a...the Android permission system is well suited for controlling access for applications in isolation, it can fail to protect resources on the device
2007-05-01
Organizational Structure 40 6.1.3 Funding Model 40 6.1.4 Role of Information Technology 40 6.2 Considering Process Improvement 41 6.2.1 Dimensions of...to the process definition for resiliency engineering. 6.1.3 Funding Model Just as organizational structures tend to align across security and...responsibility. Adopting an enter- prise view of operational resiliency and a process improvement approach requires that the funding model evolve to one
Teaching Security Requirements Engineering Using SQUARE
2011-02-01
data to show the benefit of the approach we have discussed here. So far there have been some 300 downloads of the SQUARE educational material from the...CERT website. One of our goals this year is to conduct a sur- vey to find out about the usage of the material and its results. It is our hope that in...results. For exam- ple, SQUARE educational material was translated into Chinese and delivered at National Defence University in Taiwan. Feedback from
SMC Systems Engineering: Specialty Engineering Disciplines Framework and Descriptions. Volume 2
2011-10-03
Engineering Disciplines Updale SNiEng Planning to Meet Program Objectives 1- -----:;..._- .-----------------, I Update SIW Eng T as1<s & Timing ol T asl<s...Analyses 1-Dev SNi Eng Products e.g. Assessmenls, Rills, Certs 1- ID & Manage Resources: Tools, Equip, Skills Assess Contractors’ Compian<:e to SIW Eng...Approaches to Meet SIW Ol>jeclives S1ipulale Contraclllal Risk and Actions lot Mitigations Review Contraclors’ Tech Data (Technical & Training Manuals
NASA Astrophysics Data System (ADS)
Capell, Brent M.; Was, Gary S.
2007-06-01
The mechanism of selective internal oxidation (SIO) for intergranular stress corrosion cracking (IGSCC) of nickel-base alloys has been investigated through a series of experiments using high-purity alloys and a steam environment to control the formation of NiO on the surface. Five alloys (Ni-9Fe, Ni-5Cr, Ni-5Cr-9Fe, Ni-16Cr-9Fe, and Ni-30Cr-9Fe) were used to investigate oxidation and intergranular cracking behavior for hydrogen-to-water vapor partial pressure ratios (PPRs) between 0.001 and 0.9. The Ni-9Fe, Ni-5Cr, and Ni-5Cr-9Fe alloys formed a uniform Ni(OH)2 film at PPRs less than 0.09, and the higher chromium alloys formed chromium-rich oxide films over the entire PPR range studied. Corrosion coupon results show that grain boundary oxides extended for significant depths (>150 nm) below the sample surface for all but the highest Cr containing alloy. Constant extension rate tensile (CERT) test results showed that intergranular cracking varied with PPR and cracking was more pronounced at a PPR value where nonprotective Ni(OH)2 was able to form and a link between the nonprotective Ni(OH)2 film and the formation of grain boundary oxides is suggested. The observation of grain boundary oxides in stressed and unstressed samples as well as the influence of alloy content on IG cracking and oxidation support SIO as a mechanism for IGSCC.
ERIC Educational Resources Information Center
Burris, Christopher E.
1975-01-01
Wulff v. Singleton represents the first case in which a physician has been granted standing when his sole injury arose from the possibility that he might not be paid for performing abortions. It also represents the first time a physician, as opposed to his patient, has been held to be denied equal protection. The court's rationale is examined.…
Bibliography of Publications and Presentations from July 1971 Through December 1981
1982-01-01
Bureau of Business Education, Los Angeles, California, Los Angeles, CA., January 1972; issued as Professional Paper 6-73, June 1973. PB-221 830. ED-130...Cert:. .n Types of Uniforms and Accessories (Department of the Army) Changes in Morale Subsequent to Issue Infantry Blue Clothin2 Items, by Robert L...34Bibliography of Publications as of 30 June 1971," listing and annotating the research reports issued during HumRRO’s first 20 years, 1951-71. This
2-Extendability in Two Classes of Claw-Free Graphs
1992-01-01
extendability of planar graphs, Discrete Math ., 96, 1991, 81-99. [Lai M. Las Verguas, A note on matchings in graphs, Colloque sur la Thiorie des Graphes...43, 1987, 187-222. [LP L. Loviss and M.D. Plummet, Matching Theory, Ann. Discrete Math . 29, North-Holland, Amsterdam, 1986. [P11 M.D. Plummer, On n...extendable graphs, Discrete Math . 31, 1960, 201-210. [P21 Extending matchinp in planar graphs IV, Proc. of the Conference in honor of Cert Sabidussi, Ann
Dynamic Impact Deformation Analysis Using High-speed Cameras and ARAMIS Photogrammetry Software
2010-06-01
NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Research Laboratory ATTN: RDRL-WMM-B...Aberdeen Proving Ground, MD 21005-5425 8. PERFORMING ORGANIZATION REPORT NUMBER ARL-TR-5212 9. SPONSORING/MONITORING AGENCY NAME(S) AND...desired (highlighted) panel, and then selecting the Edit option. The values in the “Name,” “Calibration scale,” “Cert. Temp.,” and “Exp. Coff
2015-01-27
Separate from analysis Indexing: • Timestamp Files • BPF Filters • GUI tools • Splunk 5 YAF PCAP Features Rolling PCAP dump • Rotates files using time...PCAP file for each flow. • Use with BPF filters. 6 Gh0st Rat Investigation 7 Gh0st Chinese remote access Trojan Free source code Easy to modify...Merge PCAP files w/ mergecap PCAP Write a BPF filter that will return session Separate Flows TCPDUMP YAF 26 Questions? CERT NetSA tools website
An Analysis of Two Layers of Encryption to Protect Network Traffic
2010-06-01
Published: 06/18/2001 CVSS Severity: 7.5 (HIGH) CVE-2001-1141 Summary: The Pseudo-Random Number Generator (PRNG) in SSLeay and OpenSSL be- fore 0.9.6b allows...x509cert function in KAME Racoon successfully verifies certifi- cates even when OpenSSL validation fails, which could allow remote attackers to...montgomery function in crypto/bn/bn mont.c in OpenSSL 0.9.8e and earlier does not properly perform Montgomery multiplication, which might allow local users to
2013-03-01
Arlington, VA 22202–4302, and to the Office of Management and Budget, Paperwork Reduction Project (0704–0188) Washington DC 20503. 1. AGENCY USE ONLY...University, 2004 Submitted in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE IN INFORMATION TECHNOLOGY MANAGEMENT...Fulp Second Reader Dr. Dan Boger Chair, Department of Information Sciences iv THIS PAGE INTENTIONALLY LEFT BLANK v ABSTRACT To secure
CERT TST November 2016 Visit Summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Little, Robert Currier; Bailey, Teresa S.; Kahler, III, Albert Comstock
2017-04-27
The dozen plus presentations covered the span of the Center’s activities, including experimental progress, simulations of the experiments (both for calibration and validation), UQ analysis, nuclear data impacts, status of simulation codes, methods development, computational science progress, and plans for upcoming priorities. All three institutions comprising the Center (Texas A&M, University of Colorado Boulder, and Simon Fraser University) were represented. Center-supported students not only gave two of the oral presentations, but also highlighted their research in a number of excellent posters.
1998-07-30
properties of gases, there are some major ite Gases, Academic Press, New York (1969). defects common to gas kinetic treatments. In hy- (1988). drodynamic...the incondensable gas are Recently, serious defects in classical gasdynamics comparable. in describing the behavior of a gas in the contin- We use the...Transition of Hypersonic, Chemically Reacting Boundary Layers J. Perraud, D. Arnal, F. Thivet ONERA CERT, DMAE , Toulouse, France 1 Introduction of
ERIC Educational Resources Information Center
Wolf, Sara Straight
1975-01-01
The author argues that if the positive values which private foundations can provide are to continue, the finding of state action in the granting of tax exemptions to private foundations cannot be permitted to stand. Other existing methods for disallowing tax exemptions for foundations dedicated to invidiously discriminatory practices are…
Secondary organic aerosol formation from primary aliphatic amines with NO3 radical
NASA Astrophysics Data System (ADS)
Malloy, Q. G. J.; Qi, Li; Warren, B.; Cocker, D. R., III; Erupe, M. E.; Silva, P. J.
2009-03-01
Primary aliphatic amines are an important class of nitrogen containing compounds emitted from automobiles, waste treatment facilities and agricultural animal operations. A series of experiments conducted at the UC-Riverside/CE-CERT Environmental Chamber is presented in which oxidation of methylamine, ethylamine, propylamine, and butylamine with O3 and NO3 have been investigated. Very little aerosol formation is observed in the presence of O3 only. However, after addition of NO, and by extension NO3, large aerosol mass yields (~44% for butylamine) are seen. Aerosol generated was determined to be organic in nature due to the small fraction of NO and NO2 in the total signal (<1% for all amines tested) as detected by an aerosol mass spectrometer (AMS). We propose a reaction mechanism between carbonyl containing species and the parent amine leading to formation of particulate imine products. These findings can have significant impacts on rural communities with elevated nighttime PM loadings, when significant levels of NO3 exist.
Secondary organic aerosol formation from primary aliphatic amines with NO3 radical
NASA Astrophysics Data System (ADS)
Malloy, Q. G. J.; Qi, Li; Warren, B.; Cocker, D. R., III; Erupe, M. E.; Silva, P. J.
2008-07-01
Primary aliphatic amines are an important class of nitrogen containing compounds found to be emitted from automobiles, waste treatment facilities and agricultural animal operations. A series of experiments conducted at the UC-Riverside/CE-CERT Environmental Chamber is presented in which oxidation of methylamine, ethylamine, propylamine, and butylamine with NO3 has been investigated. Very little aerosol formation is observed in the presence of O3 only. However, after addition of NO, and by extension NO3, large yields of aerosol mass loadings (~44% for butylamine) are seen. Aerosol generated was determined to be organic in nature due to the small fraction of NO and NO2 in the total signal (<17% for all amines tested) as detected by an aerosol mass spectrometer (AMS). We propose a reaction mechanism between carbonyl containing species and the parent amine leading to formation of particulate imine products. These findings can have significant impacts on rural communities and lead to elevated nighttime PM loadings, when significant levels on NO3 exist.
Yamaji, Toshiyuki; Horie, Aya; Tachida, Yuriko; Sakuma, Chisato; Suzuki, Yusuke; Kushi, Yasunori; Hanada, Kentaro
2016-10-21
Ceramide is a common precursor of sphingomyelin (SM) and glycosphingolipids (GSLs) in mammalian cells. Ceramide synthase 2 (CERS2), one of the six ceramide synthase isoforms, is responsible for the synthesis of very long chain fatty acid (C20-26 fatty acids) (VLC)-containing ceramides (VLC-Cer). It is known that the proportion of VLC species in GSLs is higher than that in SM. To address the mechanism of the VLC-preference of GSLs, we used genome editing to establish three HeLa cell mutants that expressed different amounts of CERS2 and compared the acyl chain lengths of SM and GSLs by metabolic labeling experiments. VLC-sphingolipid expression was increased along with that of CERS2, and the proportion of VLC species in glucosylceramide (GlcCer) was higher than that in SM for all expression levels of CERS2. This higher proportion was still maintained even when the proportion of C16-Cer to the total ceramides was increased by disrupting the ceramide transport protein (CERT)-dependent C16-Cer delivery pathway for SM synthesis. On the other hand, merging the Golgi apparatus and the endoplasmic reticulum (ER) by Brefeldin A decreased the proportion of VLC species in GlcCer probably due to higher accessibility of UDP-glucose ceramide glucosyltransferase (UGCG) to C16-rich ceramides. These results suggest the existence of a yet-to-be-identified mechanism rendering VLC-Cer more accessible than C16-Cer to UGCG, which is independent of CERT.
Active drug safety surveillance: a tool to improve public health.
Platt, Richard; Madre, Leanne; Reynolds, Robert; Tilson, Hugh
2008-12-01
Ensuring that drugs have an acceptable safety profile and are used safely is a major public health priority. The Centers for Education and Research on Therapeutics (CERTs) convened experts from academia, government, and industry to assess strategies to increase the speed and predictive value of generating and evaluating safety signals, and to identify next steps to improve the US system for identifying and evaluating potential safety signals. The CERTs convened a think tank comprising representatives of the groups noted above to address these goals. Participants observed that, with the increasing availability of electronic health data, opportunities have emerged to more accurately characterize and confirm potential safety issues. The gain for public health from a highly coordinated network of population-based databases for active surveillance is great and within reach, although operational questions remain. A collaborative network must create a working definition of a safety signal, screening algorithms, and criteria and strategies to confirm or refute a signal once identified through screening. Guidelines are needed for when and how to communicate a signal exists and is being evaluated, as well as the outcome of that evaluation. A public-private partnership to create a network of government and private databases to routinely evaluate and prioritize safety questions is in the public interest. Better methods are needed, and a knowledgeable workforce is required to conduct the surveillance and understand how to interpret the results. The international community will benefit from the availability of better methods and more experts. Copyright (c) 2008 John Wiley & Sons, Ltd.
International Space Agency CIO Forum Industrial Control System (ICS) and Cyber
NASA Technical Reports Server (NTRS)
Powell, Robert
2017-01-01
This briefing covers Industrial Control System (ICS) best practices for enhancing cyber protection. The briefing provides a very high-level overview of best practices currently being pursued by NASA as well as by other US government agencies such as NIST and DHS ICS-CERT. All information presented in this slide deck is publicly available and no sensitive information is provided in these slides. These slides will be used to generate discussion around best practices within the international community in the area of ICS cyber protections.
CERT tribal internship program. Final intern report: David Conrad, 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
The intern`s report contains a Master`s thesis entitled, ``An implementation analysis of the US Department of Energy`s American Indian policy as part of its environmental restoration and waste management mission.`` This thesis examines the implementation of a working relationship between the Nez Perce Tribe and the US Department of Energy`s Office of Environmental Restoration and Waste Management at the Hanford reservation. It examines the relationship using a qualitative methodology and three generations of policy analysis literature to gain a clear understanding of the potential for successful implementation.
CERT Resilience Management Model (RMM) v1.1: Code of Practice Crosswalk Commercial Version 1.1
2011-10-01
ISO /IEC 24762:2008 (E) 6 2.8 ISO /IEC 27002 :2005 (E) 6 2.9 ISO /IEC 27005:2008 (E) 6 2.10 ISO /IEC 31000:2009 (E) 6 2.11...webstore.ansi.org/. 2.8 ISO /IEC 27002 :2005 (E) ISO /IEC 27002 , “Code of practice for information security management” [ ISO /IEC 2005b], broaches the full...scope of security management, at points touching upon both IT management and disaster recovery. ISO /IEC 27002 is part of a growing “27000
Using social network analysis to understand Missouri's system of public health emergency planners.
Harris, Jenine K; Clements, Bruce
2007-01-01
Effective response to large-scale public health threats requires well-coordinated efforts among individuals and agencies. While guidance is available to help states put emergency planning programs into place, little has been done to evaluate the human infrastructure that facilitates successful implementation of these programs. This study examined the human infrastructure of the Missouri public health emergency planning system in 2006. The Center for Emergency Response and Terrorism (CERT) at the Missouri Department of Health and Senior Services has responsibility for planning, guiding, and funding statewide emergency response activities. Thirty-two public health emergency planners working primarily in county health departments contract with CERT to support statewide preparedness. We surveyed the planners to determine whom they communicate with, work with, seek expertise from, and exchange guidance with regarding emergency preparedness in Missouri. Most planners communicated regularly with planners in their region but seldom with planners outside their region. Planners also reported working with an average of 12 local entities (e.g., emergency management, hospitals/ clinics). Planners identified the following leaders in Missouri's public health emergency preparedness system: local public health emergency planners, state epidemiologists, the state vaccine and grant coordinator, regional public health emergency planners, State Emergency Management Agency area coordinators, the state Strategic National Stockpile coordinator, and Federal Bureau of Investigation Weapons of Mass Destruction coordinators. Generally, planners listed few federal-level or private-sector individuals in their emergency preparedness networks. While Missouri public health emergency planners maintain large and varied emergency preparedness networks, there are opportunities for strengthening existing ties and seeking additional connections.
CERT tribal internship program. Final intern report: Manuel Steele, 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The purpose of this internship was to facilitate transfer of advancements in renewable energy to Native American lands for economic and educational benefits and to assist in evaluation of proposals submitted for government funding under Title 26 Indian Energy Resources Program. Specific objectives were to examine specific cost factors stated by each Tribe for economic assessment of each proposal; assess environmental impacts of proposed scope of work presented by each Tribe; monitor existing grants for disbursement of requested funds; and provide Tribal governments with a fair and impartial review of grant proposals for funding by the Department of Energy.
NASA Astrophysics Data System (ADS)
Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves
2018-05-01
Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity (about 0.4) and with good uniformity of emissivity values (within ±0.015).
Goto, Asako; Charman, Mark; Ridgway, Neale D.
2016-01-01
Oxysterol-binding protein (OSBP) exchanges cholesterol and phosphatidylinositol 4-phosphate (PI-4P) at contact sites between the endoplasmic reticulum (ER) and the trans-Golgi/trans-Golgi network. 25-Hydroxycholesterol (25OH) competitively inhibits this exchange reaction in vitro and causes the constitutive localization of OSBP at the ER/Golgi interface and PI-4P-dependent recruitment of ceramide transfer protein (CERT) for sphingomyelin synthesis. We used PI-4P probes and mass analysis to determine how OSBP controls the availability of PI-4P for this metabolic pathway. Treatment of fibroblasts or Chinese hamster ovary (CHO) cells with 25OH caused a 50–70% reduction in Golgi-associated immunoreactive PI-4P that correlated with Golgi localization of OSBP. In contrast, 25OH caused an OSBP-dependent enrichment in Golgi PI-4P that was detected with a pleckstrin homology domain probe. The cellular mass of phosphatidylinositol monophosphates and Golgi PI-4P measured with an unbiased PI-4P probe (P4M) was unaffected by 25OH and OSBP silencing, indicating that OSBP shifts the distribution of PI-4P upon localization to ER-Golgi contact sites. The PI-4P and sterol binding activities of OSBP were both required for 25OH activation of sphingomyelin synthesis, suggesting that 25OH must be exchanged for PI-4P to be concentrated at contact sites. We propose a model wherein 25OH activation of OSBP promotes the binding and retention of PI-4P at ER-Golgi contact sites. This pool of PI-4P specifically recruits pleckstrin homology domain-containing proteins involved in lipid transfer and metabolism, such as CERT. PMID:26601944
Goto, Asako; Charman, Mark; Ridgway, Neale D
2016-01-15
Oxysterol-binding protein (OSBP) exchanges cholesterol and phosphatidylinositol 4-phosphate (PI-4P) at contact sites between the endoplasmic reticulum (ER) and the trans-Golgi/trans-Golgi network. 25-Hydroxycholesterol (25OH) competitively inhibits this exchange reaction in vitro and causes the constitutive localization of OSBP at the ER/Golgi interface and PI-4P-dependent recruitment of ceramide transfer protein (CERT) for sphingomyelin synthesis. We used PI-4P probes and mass analysis to determine how OSBP controls the availability of PI-4P for this metabolic pathway. Treatment of fibroblasts or Chinese hamster ovary (CHO) cells with 25OH caused a 50-70% reduction in Golgi-associated immunoreactive PI-4P that correlated with Golgi localization of OSBP. In contrast, 25OH caused an OSBP-dependent enrichment in Golgi PI-4P that was detected with a pleckstrin homology domain probe. The cellular mass of phosphatidylinositol monophosphates and Golgi PI-4P measured with an unbiased PI-4P probe (P4M) was unaffected by 25OH and OSBP silencing, indicating that OSBP shifts the distribution of PI-4P upon localization to ER-Golgi contact sites. The PI-4P and sterol binding activities of OSBP were both required for 25OH activation of sphingomyelin synthesis, suggesting that 25OH must be exchanged for PI-4P to be concentrated at contact sites. We propose a model wherein 25OH activation of OSBP promotes the binding and retention of PI-4P at ER-Golgi contact sites. This pool of PI-4P specifically recruits pleckstrin homology domain-containing proteins involved in lipid transfer and metabolism, such as CERT. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Integration& Operation of a Microgrid at Santa Rita Jail
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chevron Energy Solutions; Alameda County; DeForest, Nicholas
2011-05-01
Santa Rita Jail is a 4,500 inmate facility located in Dublin CA, approximately 40 miles (65 km) east of San Francisco. Over the past decade, a series of Distributed Energy Resources (DER) installations and efficiency measures have been undertaken to transform the 3MW facility into a"Green Jail". These include a 1.2MW rated rooftop PV system installed in 2002, a 1MW molten carbonate fuel cell with CHP, and retrofits to lighting and HVAC systems to reduce peak loads. With the upcoming installation of a large-scale battery and fast static disconnect switch, Santa Rita Jail will become a true microgrid, with fullmore » CERTS Microgrid functionality. Consequently, the jail will be able to seamlessly disconnect from the grid and operate as an island in the event of a disturbance, reconnecting again once the disturbance has dissipated. The extent to which that jail is capable of islanding is principally dependant on the energy capacity of the battery-one focus of this investigation. Also presented here are overviews of the DER currently installed at the jail, as well as the value it provides by offsetting the purchase of electricity under the current Pacific Gas& Electric (PG&E) tariff.« less
CERT: Center of Excellence in Rotorcraft Technology
NASA Technical Reports Server (NTRS)
2002-01-01
The research objectives of this effort are to understand the physical processes that influence the formation of the tip vortex of a rotor in advancing flight, and to develop active and passive means of weakening the tip vortex during conditions when strong blade-vortex-interaction effects are expected. A combined experimental, analytical, and computational effort is being employed. Specifically, the following efforts are being pursued: 1. Analytical evaluation and design of combined elastic tailoring and active material actuators applicable to rotor blade tips. 2. Numerical simulations of active and passive tip devices. 3. LDV Measurement of the near and far wake behind rotors in forward flight.
Cyber Security Testing and Training Programs for Industrial Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel Noyes
2012-03-01
Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall securitymore » posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These trainings vary from web-based cyber security trainings for control systems engineers to more advanced hands-on training that culminates with a Red Team/ Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.« less
Handschu, René; Scibor, Mateusz; Wacker, Angela; Stark, David R; Köhrmann, Martin; Erbguth, Frank; Oschmann, Patrick; Schwab, Stefan; Marquardt, Lars
2014-12-01
Stroke care networks with and without telemedicine have been established in several countries over the last decade to provide specialized stroke expertise to patients in rural areas. Acute consultation is a first step in the management of stroke, but not the only one. Methods of standardization of care and treatment are much needed. So far, quality management systems have only been used for single stroke units. To the best of our knowledge, we are the first stroke network worldwide to aim for certification of a network-wide quality management system. The Stroke Network Using Telemedicine in Northern Bavaria (STENO), currently with 20 associated medical institutions, is one of the world's largest stroke networks, caring for over 5000 stroke patients each year. In 2010, we initiated the implementation of a network-wide 'total' quality management system according to ISO standard 9001:2008 in cooperation with the German Stroke Society and a third-party certification organization (LGA InterCert). Certification according to ISO 9001:2008 was awarded in March 2011 and maintained over a complete certification cycle of 3 years without major deviation from the norm in three external third-party audits. Thrombolysis rate significantly increased from 8·2% (2009) to 12·8% (2012). Certified quality management within a large stroke network using telemedicine is possible and might improve stroke care procedures and thrombolysis rates. Outcome studies comparing conventional stroke care and telestroke care are inevitable. © 2014 World Stroke Organization.
Curtis, Elana; Wikaire, Erena; Jiang, Yannan; McMillan, Louise; Loto, Rob; Airini; Reid, Papaarangi
2015-01-20
Achieving health equity for indigenous and ethnic minority populations requires the development of an ethnically diverse health workforce. This study explores a tertiary admission programme targeting Māori and Pacific applicants to nursing, pharmacy and health sciences (a precursor to medicine) at the University of Auckland (UoA), Aotearoa New Zealand (NZ). Application of cognitive and non-cognitive selection tools, including a Multiple Mini Interview (MMI), are examined. Indigenous Kaupapa Māori methodology guided analysis of the Māori and Pacific Admission Scheme (MAPAS) for the years 2008-2012. Multiple logistic regression models were used to identify the predicted effect of admission variables on the final MAPAS recommendation of best starting point for success in health professional study i.e. 'CertHSc' (Certificate in Health Sciences, bridging/foundation), 'Bachelor' (degree-level) or 'Not FMHS' (Faculty of Medical and Health Sciences). Regression analyses controlled for interview year, gender and ancestry. Of the 918 MAPAS interviewees: 35% (319) were Māori, 58% (530) Pacific, 7% (68) Māori/Pacific; 71% (653) school leavers; 72% (662) females. The average rank score was 167/320, 40-80 credits below guaranteed FMHS degree offers. Just under half of all interviewees were recommended 'CertHSc' 47% (428), 13% (117) 'Bachelor' and 38% (332) 'Not FMHS' as the best starting point. Strong associations were identified between Bachelor recommendation and exposure to Any 2 Sciences (OR:7.897, CI:3.855-16.175; p < 0.0001), higher rank score (OR:1.043, CI:1.034-1.052; p < 0.0001) and higher scores on MAPAS mathematics test (OR:1.043, CI:1.028-1.059; p < 0.0001). MMI stations had mixed associations, with academic preparation and career aspirations more consistently associated with recommendations. Our findings raise concerns about the ability of the secondary education sector to prepare Māori and Pacific students adequately for health professional study. A comprehensive tertiary admissions process using multiple tools for selection (cognitive and non-cognitive) and the provision of alternative entry pathways are recommended for indigenous and ethnic minority health workforce development. The application of the MMI within an equity and indigenous cultural context can support a holistic assessment of an applicant's potential to succeed within tertiary study. The new MAPAS admissions process may provide an exemplar for other tertiary institutions looking to widen participation via equity-targeted admission processes.
The Pericles Space Case: Preserving Earth Observation Data for the Future
NASA Astrophysics Data System (ADS)
Muller, C.; Pandey, P.; Pericles Consortium
2016-08-01
PERICLES (Promoting and Enhancing the Reuse of Information throughout the Content Lifecycle exploiting Evolving Semantics) is an FP7 project started on February 2013. It aims at preserving by design large and complex data sets. PERICLES is coordinated by King's College London, UK and its partners are University of Borås (Sweden), CERT (Greece), DotSoft(Greece), GeorgAugustUniversität, Göttingen (Germany), University of Liverpool (UK), Space Application Services (Belgium), XEROX France and University of Edinburgh (UK). Two additional partners provide the case studies: Tate Gallery (UK) brings the digital art and media case study and B.USOC (Belgian Users Support and Operations Centre) brings the space science case study.
A Novel Control Strategy for Autonomous Operation of Isolated Microgrid with Prioritized Loads
NASA Astrophysics Data System (ADS)
Kumar, R. Hari; Ushakumari, S.
2018-05-01
Maintenance of power balance between generation and demand is one of the most critical requirements for the stable operation of a power system network. To mitigate the power imbalance during the occurrence of any disturbance in the system, fast acting algorithms are inevitable. This paper proposes a novel algorithm for load shedding and network reconfiguration in an isolated microgrid with prioritized loads and multiple islands, which will help to quickly restore the system in the event of a fault. The performance of the proposed algorithm is enhanced using genetic algorithm and its effectiveness is illustrated with simulation results on modified Consortium for Electric Reliability Technology Solutions (CERTS) microgrid.
Insider Threat Assessment: Model, Analysis and Tool
NASA Astrophysics Data System (ADS)
Chinchani, Ramkumar; Ha, Duc; Iyer, Anusha; Ngo, Hung Q.; Upadhyaya, Shambhu
Insider threat is typically attributed to legitimate users who maliciously leverage their system privileges, and familiarity and proximity to their computational environment to compromise valuable information or inflict damage. According to the annual CSI/FBI surveys conducted since 1996, internal attacks and insider abuse form a significant portion of reported incidents. The strongest indication yet that insider threat is very real is given by the recent study [2] jointly conducted by CERT and the US Secret Service; the first of its kind, which provides an in-depth insight into the problem in a real-world setting. However, there is no known body of work which addresses this problem effectively. There are several challenges, beginning with understanding the threat.
CERT tribal internship program. Final intern report: Lewis Yellowrobe, 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
The purpose of this internship was to present state legislators with the history and an overview of the Department of Energy`s policies towards occupational health and safety during cleanup of nuclear weapons production facilities. The approach used library research and phone and personal interviews to acquire information on DOE policies. This intern report contains the final report to legislators entitled ``Environmental restoration and waste management: Worker health and safety concerns during nuclear facility cleanup.`` It presents the current status of DOE occupational health and safety at production facilities, Congressional intent, past DOE occupational policies, and options for state legislators tomore » use to get involved with DOE policy direction.« less
L'Italien, G; Ford, I; Norrie, J; LaPuerta, P; Ehreth, J; Jackson, J; Shepherd, J
2000-03-15
The clinical decision to treat hypercholesterolemia is premised on an awareness of patient risk, and cardiac risk prediction models offer a practical means of determining such risk. However, these models are based on observational cohorts where estimates of the treatment benefit are largely inferred. The West of Scotland Coronary Prevention Study (WOSCOPS) provides an opportunity to develop a risk-benefit prediction model from the actual observed primary event reduction seen in the trial. Five-year Cox model risk estimates were derived from all WOSCOPS subjects (n = 6,595 men, aged 45 to 64 years old at baseline) using factors previously shown to be predictive of definite fatal coronary heart disease or nonfatal myocardial infarction. Model risk factors included age, diastolic blood pressure, total cholesterol/ high-density lipoprotein ratio (TC/HDL), current smoking, diabetes, family history of fatal coronary heart disease, nitrate use or angina, and treatment (placebo/ 40-mg pravastatin). All risk factors were expressed as categorical variables to facilitate risk assessment. Risk estimates were incorporated into a simple, hand-held slide rule or risk tool. Risk estimates were identified for 5-year age bands (45 to 65 years), 4 categories of TC/HDL ratio (<5.5, 5.5 to <6.5, 6.5 to <7.5, > or = 7.5), 2 levels of diastolic blood pressure (<90, > or = 90 mm Hg), from 0 to 3 additional risk factors (current smoking, diabetes, family history of premature fatal coronary heart disease, nitrate use or angina), and pravastatin treatment. Five-year risk estimates ranged from 2% in very low-risk subjects to 61% in the very high-risk subjects. Risk reduction due to pravastatin treatment averaged 31%. Thus, the Cardiovascular Event Reduction Tool (CERT) is a risk prediction model derived from the WOSCOPS trial. Its use will help physicians identify patients who will benefit from cholesterol reduction.
Meaningful Use of Electronic Health Records: Experiences From the Field and Future Opportunities.
Slight, Sarah Patricia; Berner, Eta S; Galanter, William; Huff, Stanley; Lambert, Bruce L; Lannon, Carole; Lehmann, Christoph U; McCourt, Brian J; McNamara, Michael; Menachemi, Nir; Payne, Thomas H; Spooner, S Andrew; Schiff, Gordon D; Wang, Tracy Y; Akincigil, Ayse; Crystal, Stephen; Fortmann, Stephen P; Bates, David W
2015-09-18
With the aim of improving health care processes through health information technology (HIT), the US government has promulgated requirements for "meaningful use" (MU) of electronic health records (EHRs) as a condition for providers receiving financial incentives for the adoption and use of these systems. Considerable uncertainty remains about the impact of these requirements on the effective application of EHR systems. The Agency for Healthcare Research and Quality (AHRQ)-sponsored Centers for Education and Research in Therapeutics (CERTs) critically examined the impact of the MU policy relating to the use of medications and jointly developed recommendations to help inform future HIT policy. We gathered perspectives from a wide range of stakeholders (N=35) who had experience with MU requirements, including academicians, practitioners, and policy makers from different health care organizations including and beyond the CERTs. Specific issues and recommendations were discussed and agreed on as a group. Stakeholders' knowledge and experiences from implementing MU requirements fell into 6 domains: (1) accuracy of medication lists and medication reconciliation, (2) problem list accuracy and the shift in HIT priorities, (3) accuracy of allergy lists and allergy-related standards development, (4) support of safer and effective prescribing for children, (5) considerations for rural communities, and (6) general issues with achieving MU. Standards are needed to better facilitate the exchange of data elements between health care settings. Several organizations felt that their preoccupation with fulfilling MU requirements stifled innovation. Greater emphasis should be placed on local HIT configurations that better address population health care needs. Although MU has stimulated adoption of EHRs, its effects on quality and safety remain uncertain. Stakeholders felt that MU requirements should be more flexible and recognize that integrated models may achieve information-sharing goals in alternate ways. Future certification rules and requirements should enhance EHR functionalities critical for safer prescribing of medications in children.
Kornacka, Monika; Buczny, Jacek; Layton, Rebekah L
2016-01-01
Repetitive negative thinking (RNT) is a transdiagnostic process involved in the risk, maintenance, and relapse of serious conditions including mood disorders, anxiety, eating disorders, and addictions. Processing mode theory provides a theoretical model to assess, research, and treat RNT using a transdiagnostic approach. Clinical researchers also often employ categorical approaches to RNT, including a focus on depressive rumination or worry, for similar purposes. Three widely used self-report questionnaires have been developed to assess these related constructs: the Ruminative Response Scale (RRS), the Perseverative Thinking Questionnaire (PTQ), and the Mini-Cambridge Exeter Repetitive Thought Scale (Mini-CERTS). Yet these scales have not previously been used in conjunction, despite useful theoretical distinctions only available in Mini-CERTS. The present validation of the methods in a Polish speaking population provides psychometric parameters estimates that contribute to current efforts to increase reliable replication of theoretical outcomes. Moreover, the following study aims to present particular characteristics and a comparison of the three methods. Although there has been some exploration of a categorical approach, the comparison of transdiagnostic methods is still lacking. These methods are particularly relevant for developing and evaluating theoretically based interventions like concreteness training, an emerging field of increasing interest, which can be used to address the maladaptive processing mode in RNT that can lead to depression and other disorders. Furthermore, the translation of these measures enables the examination of possible cross-cultural structural differences that may lead to important theoretical progress in the measurement and classification of RNT. The results support the theoretical hypothesis. As expected, the dimensions of brooding, general repetitive negative thinking, as well as abstract analytical thinking, can all be classified as unconstructive repetitive thinking. The particular characteristics of each scale and potential practical applications in clinical and research are discussed.
Bennie, Jason A; Thornton, Lukar E; van Uffelen, Jannique G Z; Banting, Lauren K; Biddle, Stuart J H
2016-07-11
Leisure-time physical activity and strength training participation levels are low and socioeconomically distributed. Fitness trainers (e.g. gym/group instructors) may have a role in increasing these participation levels. However, it is not known whether the training location and characteristics of Australian fitness trainers vary between areas that differ in socioeconomic status. In 2014, a sample of 1,189 Australian trainers completed an online survey with questions about personal and fitness industry-related characteristics (e.g. qualifications, setting, and experience) and postcode of their usual training location. The Australian Bureau of Statistics 'Index of Relative Socioeconomic Disadvantage' (IRSD) was matched to training location and used to assess where fitness professionals trained and whether their experience, qualification level and delivery methods differed by area-level disadvantage. Linear regression analysis was used to examine the relationship between IRSD score and selected characteristics adjusting for covariates (e.g. sex, age). Overall, 47 % of respondents worked in areas within the three least-disadvantaged deciles. In contrast, only 14.8 % worked in the three most-disadvantaged deciles. In adjusted regression models, fitness industry qualification was positively associated with a higher IRSD score (i.e. working in the least-disadvantaged areas) (Cert III: ref; Cert IV β:13.44 [95 % CI 3.86-23.02]; Diploma β:15.77 [95 % CI: 2.17-29.37]; Undergraduate β:23.14 [95 % CI: 9.41-36.86]). Fewer Australian fitness trainers work in areas with high levels of socioeconomic disadvantaged areas than in areas with low levels of disadvantage. A higher level of fitness industry qualifications was associated with working in areas with lower levels of disadvantage. Future research should explore the effectiveness of providing incentives that encourage more fitness trainers and those with higher qualifications to work in more socioeconomically disadvantaged areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orvis, W.J.
1993-11-03
The Computer Incident Advisory Capability (CIAC) operates two information servers for the DOE community, FELICIA (formerly FELIX) and IRBIS. FELICIA is a computer Bulletin Board System (BBS) that can be accessed by telephone with a modem. IRBIS is an anonymous ftp server that can be accessed on the Internet. Both of these servers contain all of the publicly available CIAC, CERT, NIST, and DDN bulletins, virus descriptions, the VIRUS-L moderated virus bulletin board, copies of public domain and shareware virus- detection/protection software, and copies of useful public domain and shareware utility programs. This guide describes how to connect these systemsmore » and obtain files from them.« less
Adding the Fourth "R": A Systems Approach to Solving the Hacker's Arms Race
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endicott-Popovsky, Barbara E.; Frincke, Deborah A.
2006-01-01
In this paper, the authors propose a modification of CERT's 3 R model to include a 4 th R, the discipline of Redress, identified as a necessary step to end the hacker arms race. Redress will require implementation of computer forensic investigation methods, tools and techniques that will permit evidence gathered to be admissible in a court of law, a standard not often understood or followed by many who are responsible for securing networks today. This leads the authors to conclude that there is a need for future work that will involve re-examination of the mechanisms and procedures used tomore » collect evidence of network intrusions in order to ensure that the Rules of Evidence requirements are considered.« less
CERT tribal internship program. Final intern report: D`Lisa Penney, 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
The purpose of this intern`s project was to: education the Nez Perce people of the Hanford situation; begin researching into past and present health effects from the Hanford site; and inform and educate the Nez Perce people of the Hanford site and past exposures. The specific objectives were to begin researching the history of Nez Perce people and Hanford; create an understanding for the importance of this research; define the radiation and risks and how they occur; inform the Nez Perce people of the issue; and write the paper so it is easy to understand. This intern report contains amore » copy of the final paper written for the Nez Perce people. Because the dose reconstruction for Hanford is not complete, the health effects section is informative, but not definitive.« less
NASA Astrophysics Data System (ADS)
Chen, Chia-Li; Li, Lijie; Tang, Ping; Cocker, David R.
2018-05-01
SOA formation is not well predicted in current models in urban area. The interaction among multiple anthropogenic volatile organic compounds is essential for the SOA formation in the complex urban atmosphere. Secondary organic aerosol (SOA) from the photooxidation of naphthalene, 1-methylnaphthalene, and 2-methylnaphthalene as well as individual polycyclic aromatic hydrocarbons (PAHs) mixed with m-xylene or an atmospheric surrogate mixture was explored in the UCR CE-CERT environmental chamber under urban relevant low NOx and extremely low NOx (H2O2) conditions. Addition of m-xylene suppressed SOA formation from the individual PAH precursor. A similar suppression effect on SOA formation was observed during the surrogate mixture photooxidation suggesting the importance of gas-phase chemical reactivity to SOA formation. The SOA growth rate for different PAH-m-xylene mixtures was strongly correlated with initial [HO2]/[RO2] ratio but negatively correlated with initial m-xylene/NO ratio. Decreasing SOA formation was observed for increasing m-xylene/PAHs ratios and increasing initial m-xylene/NO ratio. The SOA chemical composition characteristics such as f44 versus f43, H/C ratio, O/C ratio, and the oxidation state of the carbon OSbarc were consistent with a continuously aging with the SOA exhibiting characteristics of both individual precursors. SOA formation from PAHs was also suppressed within an atmospheric surrogate mixture compared to the SOA formed from individual PAHs, indicating that atmospheric reactivity directly influences SOA formation from PAHs.
Treatment of maladaptive aggression in youth: CERT guidelines II. Treatments and ongoing management.
Scotto Rosato, Nancy; Correll, Christoph U; Pappadopulos, Elizabeth; Chait, Alanna; Crystal, Stephen; Jensen, Peter S
2012-06-01
To develop guidelines for management and treatment of maladaptive aggression in youth in the areas of psychosocial interventions, medication treatments, and side-effect management. Evidence was assembled and evaluated in a multistep process, including systematic reviews of published literature; an expert survey of recommended practices; a consensus conference of researchers, policymakers, clinicians, and family advocates; and review by the steering committee of successive drafts of the recommendations. The Center for Education and Research on Mental Health Therapeutics Treatment of Maladaptive Aggression in Youth guidelines reflect a synthesis of the available evidence, based on this multistep process. This article describes the content, rationale, and evidence for 11 recommendations. Key treatment principles include considering psychosocial interventions, such as evidence-based parent and child skills training as the first line of treatment; targeting the underlying disorder first following evidence-based guidelines; considering individual psychosocial and medical factors, including cardiovascular risk in the selection of agents if medication treatment (ideally with the best evidence base) is initiated; avoiding the use of multiple psychotropic medications simultaneously; and careful monitoring of treatment response, by using structured rating scales, as well as close medical monitoring for side effects, including metabolic changes. Treatment of children with maladaptive aggression is a "moving target" requiring ongoing assimilation of new evidence as it emerges. Based on the existing evidence, the Treatment of Maladaptive Aggression in Youth guidelines provide a framework for management of maladaptive aggression in youth, appropriate for use by primary care clinicians and mental health providers.
Assessing the Macro-Level Correlates of Malware Infections Using a Routine Activities Framework.
Holt, Thomas J; Burruss, George W; Bossler, Adam M
2018-05-01
The ability to gain unauthorized access to computer systems to engage in espionage and data theft poses a massive threat to individuals worldwide. There has been minimal focus, however, on the role of malicious software, or malware, which can automate this process. This study examined the macro-correlates of malware infection at the national level by using an open repository of known malware infections and utilizing a routine activities framework. Negative inflated binomial models for counts indicated that nations with greater technological infrastructure, more political freedoms, and with less organized crime financial impact were more likely to report malware infections. The number of Computer Emergency Response Teams (CERTs) in a nation was not significantly related with reported malware infection. The implications of the study for the understanding of malware infection, routine activity theory, and target-hardening strategies are discussed.
Practical Computer Security through Cryptography
NASA Technical Reports Server (NTRS)
McNab, David; Twetev, David (Technical Monitor)
1998-01-01
The core protocols upon which the Internet was built are insecure. Weak authentication and the lack of low level encryption services introduce vulnerabilities that propagate upwards in the network stack. Using statistics based on CERT/CC Internet security incident reports, the relative likelihood of attacks via these vulnerabilities is analyzed. The primary conclusion is that the standard UNIX BSD-based authentication system is by far the most commonly exploited weakness. Encryption of Sensitive password data and the adoption of cryptographically-based authentication protocols can greatly reduce these vulnerabilities. Basic cryptographic terminology and techniques are presented, with attention focused on the ways in which technology such as encryption and digital signatures can be used to protect against the most commonly exploited vulnerabilities. A survey of contemporary security software demonstrates that tools based on cryptographic techniques, such as Kerberos, ssh, and PGP, are readily available and effectively close many of the most serious security holes. Nine practical recommendations for improving security are described.
NINJA: a noninvasive framework for internal computer security hardening
NASA Astrophysics Data System (ADS)
Allen, Thomas G.; Thomson, Steve
2004-07-01
Vulnerabilities are a growing problem in both the commercial and government sector. The latest vulnerability information compiled by CERT/CC, for the year ending Dec. 31, 2002 reported 4129 vulnerabilities representing a 100% increase over the 2001 [1] (the 2003 report has not been published at the time of this writing). It doesn"t take long to realize that the growth rate of vulnerabilities greatly exceeds the rate at which the vulnerabilities can be fixed. It also doesn"t take long to realize that our nation"s networks are growing less secure at an accelerating rate. As organizations become aware of vulnerabilities they may initiate efforts to resolve them, but quickly realize that the size of the remediation project is greater than their current resources can handle. In addition, many IT tools that suggest solutions to the problems in reality only address "some" of the vulnerabilities leaving the organization unsecured and back to square one in searching for solutions. This paper proposes an auditing framework called NINJA (acronym for Network Investigation Notification Joint Architecture) for noninvasive daily scanning/auditing based on common security vulnerabilities that repeatedly occur in a network environment. This framework is used for performing regular audits in order to harden an organizations security infrastructure. The framework is based on the results obtained by the Network Security Assessment Team (NSAT) which emulates adversarial computer network operations for US Air Force organizations. Auditing is the most time consuming factor involved in securing an organization's network infrastructure. The framework discussed in this paper uses existing scripting technologies to maintain a security hardened system at a defined level of performance as specified by the computer security audit team. Mobile agents which were under development at the time of this writing are used at a minimum to improve the noninvasiveness of our scans. In general, noninvasive scans with an adequate framework performed on a daily basis reduce the amount of security work load as well as the timeliness in performing remediation, as verified by the NINJA framework. A vulnerability assessment/auditing architecture based on mobile agent technology is proposed and examined at the end of the article as an enhancement to the current NINJA architecture.
Prony Ringdown GUI (CERTS Prony Ringdown, part of the DSI Tool Box)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuffner, Francis; Marinovici, PNNL Laurentiu; Hauer, PNNL John
2014-02-21
The PNNL Prony Ringdown graphical user interface is one analysis tool included in the Dynamic System Identification toolbox (DSI Toolbox). The Dynamic System Identification toolbox is a MATLAB-based collection of tools for parsing and analyzing phasor measurement unit data, especially in regards to small signal stability. It includes tools to read the data, preprocess it, and perform small signal analysis. 5. Method of Solution: The Dynamic System Identification Toolbox (DSI Toolbox) is designed to provide a research environment for examining phasor measurement unit data and performing small signal stability analysis. The software uses a series of text-driven menus to helpmore » guide users and organize the toolbox features. Methods for reading in populate phasor measurement unit data are provided, with appropriate preprocessing options for small-signal-stability analysis. The toolbox includes the Prony Ringdown GUI and basic algorithms to estimate information on oscillatory modes of the system, such as modal frequency and damping ratio.« less
Defining and Enabling Resiliency of Electric Distribution Systems With Multiple Microgrids
Chanda, Sayonsom; Srivastava, Anurag K.
2016-05-02
This paper presents a method for quantifying and enabling the resiliency of a power distribution system (PDS) using analytical hierarchical process and percolation theory. Using this metric, quantitative analysis can be done to analyze the impact of possible control decisions to pro-actively enable the resilient operation of distribution system with multiple microgrids and other resources. Developed resiliency metric can also be used in short term distribution system planning. The benefits of being able to quantify resiliency can help distribution system planning engineers and operators to justify control actions, compare different reconfiguration algorithms, develop proactive control actions to avert power systemmore » outage due to impending catastrophic weather situations or other adverse events. Validation of the proposed method is done using modified CERTS microgrids and a modified industrial distribution system. Furthermore, simulation results show topological and composite metric considering power system characteristics to quantify the resiliency of a distribution system with the proposed methodology, and improvements in resiliency using two-stage reconfiguration algorithm and multiple microgrids.« less
Saxon, Leslie A; Varma, Niraj; Epstein, Laurence M; Ganz, Leonard I; Epstein, Andrew E
2018-05-10
In August 2017, the first major recall for cybersecurity vulnerabilities in pacemakers capable of remote connectivity was released that impacted 465,000 United States patients. 1,2 The FDA approved a firmware update designed by the manufacturer of the devices as a remediation (Abbott , formally St. Jude Medical). The recall was in response to the public disclosure of vulnerability by an investment firm and produced in a lab environment that could allow an unauthorized party in close proximity to a patient to impact the performance of the device or modify device settings via radio frequency communication. 3 While an exploit has not occurred in a patient and requires a high degree of resources and skill to execute, if accomplished, it could pose a significant risk to device safety and essential performance and cause patient harm. The FDA defines this as an uncontrolled vulnerability. 2 The recall recommendations were coordinated between the FDA, the Industrial Control Systems Cyber Emergency Response Team (ICS-CERT), a division of Homeland Security that responds to and coordinates disclosure of critical infrastructure cybersecurity vulnerabilities and Abbott. 1 All parties urged caution and shared decision making between patient and clinician as to whether to have the device firmware update, a process that requires a clinic visit to implement with a device programmer. The manufacturer bench tested the firmware update but the only prior experience with an implanted device firmware updates was a 2012 ICD firmware update that demonstrated a 0.197% risk of device back-up mode pacing after the upgrade was performed.
Slade, Susan C; Hay-Smith, Jean; Mastwyk, Sally; Morris, Meg E; Frawley, Helena
2018-05-24
The experiences and information needs of clinicians who use pelvic floor muscle training to manage urinary incontinence were explored. Qualitative methods were used to conduct thematic analysis of data collected from clinician focus groups and interviews. Participants were registered physiotherapists and continence nurses in Melbourne, Australia. Recruitment was through a combination of purposive and "snowball" sampling and continued until data adequacy was reached. Twenty-eight physiotherapists and one continence nurse participated in seven focus groups and one interview. The main finding communicated by the participants was that pelvic floor muscle training requires comprehensive descriptions of program details in order for clinicians to implement evidence-based interventions. The following themes were identified: (1) pelvic floor muscle training tailored to the needs of each individual is essential; (2) training-specific cues and verbal prompts assist patients to learn and engage with exercises; and (3) clinicians can benefit from research summaries and reports that provide explicit and comprehensive descriptions and decision rules about intervention content and progression. The data indicated that some clinicians can have difficulty interpreting and applying research findings because it is not always well reported. Clinicians who use pelvic floor muscle training to treat urinary incontinence advised can benefit from accessing explicit details of interventions tested in research and reported as effective. They viewed tailoring therapy to individual goals and the use of verbal prompts and visualization cues as important engagement strategies for effective exercise performance. Explicit reporting could be facilitated by using an exercise guideline template, such as the Consensus on Exercise Reporting Template (CERT). © 2018 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Sung, J. K.; Koch, J.; Angeliu, T.; Was, G. S.
1992-10-01
The role of chromium, carbon, chromium carbides, and phosphorus on the intergranular stress corrosion cracking (IGSCC) resistance of Ni-Cr-Fe alloys in 50 pct NaOH at 140 °C is studied using controlled-purity alloys. The effect of carbon is studied using heats in which the carbon level is varied between 0.002 and 0.063 wt pct while the Cr level is fixed at 16.8 wt pct. The effect of Cr is studied using alloys with Cr concentrations between 5 and 30 wt pct. The effect of grain boundary Cr and C together is studied by heat-treating the nominal alloy composition of Ni-16Cr-9Fe-0.035C, and the effect of P is studied using a high-purity, P-doped alloy and a carbon-containing, P-doped alloy. Constant extension rate tensile (CERT) results show that the crack depth increases with decreasing alloy Cr content and increasing alloy C content. Crack- ing severity also correlates inversely with thermal treatment time at 700 °C, during which the grain boundary Cr content rises and the grain boundary C content falls. Phosphorus is found to have a slightly beneficial effect on IG cracking susceptibility. Potentiodynamic polarization and potentiostatic current decay experiments confirm that Cr depletion or grain boundary C enhances the dissolution at the grain boundary. Results support a film rupture-anodic dissolution model in which Cr depletion or grain boundary C (independently or additively) enhances dissolution of nickel from the grain boundary region and leads to increased IG cracking.
A Multimodal Emotion Detection System during Human-Robot Interaction
Alonso-Martín, Fernando; Malfaz, María; Sequeira, João; Gorostiza, Javier F.; Salichs, Miguel A.
2013-01-01
In this paper, a multimodal user-emotion detection system for social robots is presented. This system is intended to be used during human–robot interaction, and it is integrated as part of the overall interaction system of the robot: the Robotics Dialog System (RDS). Two modes are used to detect emotions: the voice and face expression analysis. In order to analyze the voice of the user, a new component has been developed: Gender and Emotion Voice Analysis (GEVA), which is written using the Chuck language. For emotion detection in facial expressions, the system, Gender and Emotion Facial Analysis (GEFA), has been also developed. This last system integrates two third-party solutions: Sophisticated High-speed Object Recognition Engine (SHORE) and Computer Expression Recognition Toolbox (CERT). Once these new components (GEVA and GEFA) give their results, a decision rule is applied in order to combine the information given by both of them. The result of this rule, the detected emotion, is integrated into the dialog system through communicative acts. Hence, each communicative act gives, among other things, the detected emotion of the user to the RDS so it can adapt its strategy in order to get a greater satisfaction degree during the human–robot dialog. Each of the new components, GEVA and GEFA, can also be used individually. Moreover, they are integrated with the robotic control platform ROS (Robot Operating System). Several experiments with real users were performed to determine the accuracy of each component and to set the final decision rule. The results obtained from applying this decision rule in these experiments show a high success rate in automatic user emotion recognition, improving the results given by the two information channels (audio and visual) separately. PMID:24240598
Materials for Advanced Ultrasupercritical Steam Turbines Task 4: Cast Superalloy Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thangirala, Mani
The Steam Turbine critical stationary structural components are high integrity Large Shell and Valve Casing heavy section Castings, containing high temperature steam under high pressures. Hence to support the development of advanced materials technology for use in an AUSC steam turbine capable of operating with steam conditions of 760°C (1400°F) and 35 Mpa (5000 psia), Casting alloy selection and evaluation of mechanical, metallurgical properties and castability with robust manufacturing methods are mandated. Alloy down select from Phase 1 based on producability criteria and creep rupture properties tested by NETL-Albany and ORNL directed the consortium to investigate cast properties of Haynesmore » 282 and Haynes 263. The goals of Task 4 in Phase 2 are to understand a broader range of mechanical properties, the impact of manufacturing variables on those properties. Scale up the size of heats to production levels to facilitate the understanding of the impact of heat and component weight, on metallurgical and mechanical behavior. GE Power & Water Materials and Processes Engineering for the Phase 2, Task 4.0 Castings work, systematically designed and executed casting material property evaluation, multiple test programs. Starting from 15 lbs. cylinder castings to world’s first 17,000 lbs. poured weight, heavy section large steam turbine partial valve Haynes 282 super alloy casting. This has demonstrated scalability of the material for steam Turbine applications. Activities under Task 4.0, Investigated and characterized various mechanical properties of Cast Haynes 282 and Cast Nimonic 263. The development stages involved were: 1) Small Cast Evaluation: 4 inch diam. Haynes 282 and Nimonic 263 Cylinders. This provided effects of liquidus super heat range and first baseline mechanical data on cast versions of conventional vacuum re-melted and forged Ni based super alloys. 2) Step block castings of 300 lbs. and 600 lbs. Haynes 282 from 2 foundry heats were evaluated which demonstrated the importance of proper heat treat cycles for Homogenization, and Solutionizing parameters selection and implementation. 3) Step blocks casting of Nimonic 263: Carried out casting solidification simulation analysis, NDT inspection methods evaluation, detailed test matrix for Chemical, Tensile, LCF, stress rupture, CVN impact, hardness and J1C Fracture toughness section sensitivity data and were reported. 4) Centrifugal Casting of Haynes 282, weighing 1400 lbs. with hybrid mold (half Graphite and half Chromite sand) mold assembly was cast using compressor casing production tooling. This test provided Mold cooling rates influence on centrifugally cast microstructure and mechanical properties. Graphite mold section out performs sand mold across all temperatures for 0.2% YS; %Elongation, %RA, UTS at 1400°F. Both Stress-LMP and conditional Fracture toughness plots data were in the scatter band of the wrought alloy. 5) Fundamental Studies on Cooling rates and SDAS test program. Evaluated the influence of 6 mold materials Silica, Chromite, Alumina, Silica with Indirect Chills, Zircon and Graphite on casting solidification cooling rates. Actual Casting cooling rates through Liquidus to Solidus phase transition were measured with 3 different locations based thermocouples placed in each mold. Compared with solidification simulation cooling rates and measurement of SDAS, microstructure features were reported. The test results provided engineered casting potential methods, applicable for heavy section Haynes 282 castings for optimal properties, with foundry process methods and tools. 6) Large casting of Haynes 282 Drawings and Engineering FEM models and supplemental requirements with applicable specifications were provided to suppliers for the steam turbine proto type feature valve casing casting. Molding, melting and casting pouring completed per approved Manufacturing Process Plan during 2014 Q4. The partial valve casing was successfully cast after casting methods were validated with solidification simulation analysis and the casting met NDT inspection and acceptance criteria. Heat treated and sectioned to extract trepan samples at different locations comparing with cast on coupons test data. Material properties requisite for design, such as tensile, creep/rupture, LCF, Fracture Toughness, Charpy V-notch chemical analysis testing were carried out. The test results will be presented in the final report. The typical Haynes 282 large size Steam Turbine production casting from Order to Delivery foundry schedule with the activity break up is shown in Figures 107 and 108. • From Purchase Order placement to Casting pouring ~ 26 weeks. 1. Sales and commercial review 3 2. Engineering Drawings/models review 4 3. Pattern and core box manufacturing 6 4. Casting process engineering review 4 5. FEM and solidification simulation analysis 4 6. Gating & Feeder Attachments, Ceramic tiling 2 7. Molding and coremaking production scheduling 6 8. Melting planning and schedule 3 9. Pouring, cooling and shake out 2 • From Pouring to casting Delivery ~ 29 weeks 10. Shot blast and riser cutting, gates removal 3 11. Homogenizing , solutionizing HT furnace prep 4 12. Grinding, Fettling 2 13. Aging HT Cycle, cooling 2 14. VT and LPT NDT inspections 2 15. Radiographic inspection 4 16. Mechanical testing, Chemical analysis test certs 4 17. Casting weld repair upgrades and Aging PWHT 4 18. NDT after weld repairs and casting upgrades 3 19. Casting Final Inspection and test certifications 3 20. Package and delivery 2 Hence the Total Lead time from P.O to Casting delivery is approximately 55 weeks. The Task 4.2 and Task 4.3 activities and reporting completed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eto, Joseph H.; Parashar, Manu; Lewis, Nancy Jo
The Real Time System Operations (RTSO) 2006-2007 project focused on two parallel technical tasks: (1) Real-Time Applications of Phasors for Monitoring, Alarming and Control; and (2) Real-Time Voltage Security Assessment (RTVSA) Prototype Tool. The overall goal of the phasor applications project was to accelerate adoption and foster greater use of new, more accurate, time-synchronized phasor measurements by conducting research and prototyping applications on California ISO's phasor platform - Real-Time Dynamics Monitoring System (RTDMS) -- that provide previously unavailable information on the dynamic stability of the grid. Feasibility assessment studies were conducted on potential application of this technology for small-signal stabilitymore » monitoring, validating/improving existing stability nomograms, conducting frequency response analysis, and obtaining real-time sensitivity information on key metrics to assess grid stress. Based on study findings, prototype applications for real-time visualization and alarming, small-signal stability monitoring, measurement based sensitivity analysis and frequency response assessment were developed, factory- and field-tested at the California ISO and at BPA. The goal of the RTVSA project was to provide California ISO with a prototype voltage security assessment tool that runs in real time within California ISO?s new reliability and congestion management system. CERTS conducted a technical assessment of appropriate algorithms, developed a prototype incorporating state-of-art algorithms (such as the continuation power flow, direct method, boundary orbiting method, and hyperplanes) into a framework most suitable for an operations environment. Based on study findings, a functional specification was prepared, which the California ISO has since used to procure a production-quality tool that is now a part of a suite of advanced computational tools that is used by California ISO for reliability and congestion management.« less
Richmond, Helen; Lait, Clare; Srikesavan, Cynthia; Williamson, Esther; Moser, Jane; Newman, Meredith; Betteley, Lauren; Fordham, Beth; Rees, Sophie; Lamb, Sarah E; Bruce, Julie
2018-06-18
Musculoskeletal shoulder problems are common after breast cancer treatment. There is some evidence to suggest that early postoperative exercise is safe and may improve shoulder function. We describe the development and delivery of a complex intervention for evaluation within a randomised controlled trial (RCT), designed to target prevention of musculoskeletal shoulder problems after breast cancer surgery (The Prevention of Shoulder Problems Trial; PROSPER). A pragmatic, multicentre RCT to compare the clinical and cost-effectiveness of best practice usual care versus a physiotherapy-led exercise and behavioural support intervention in women at high risk of shoulder problems after breast cancer treatment. PROSPER will recruit 350 women from approximately 15 UK centres, with follow-up at 6 and 12 months. The primary outcome is shoulder function at 12 months; secondary outcomes include postoperative pain, health related quality of life, adverse events and healthcare resource use. A multi-phased approach was used to develop the PROSPER intervention which was underpinned by existing evidence and modified for implementation after input from clinical experts and women with breast cancer. The intervention was tested and refined further after qualitative interviews with patients newly diagnosed with breast cancer; a pilot RCT was then conducted at three UK clinical centres. The PROSPER intervention incorporates three main components: shoulder-specific exercises targeting range of movement and strength; general physical activity; and behavioural strategies to encourage adherence and support exercise behaviour. The final PROSPER intervention is fully manualised with clear, documented pathways for clinical assessment, exercise prescription, use of behavioural strategies, and with guidance for treatment of postoperative complications. This paper adheres to TIDieR and CERT recommendations for the transparent, comprehensive and explicit reporting of complex interventions. International Standard Randomised Controlled Trial Number: ISRCTN 35358984 .
The HACMS program: using formal methods to eliminate exploitable bugs
Launchbury, John; Richards, Raymond
2017-01-01
For decades, formal methods have offered the promise of verified software that does not have exploitable bugs. Until recently, however, it has not been possible to verify software of sufficient complexity to be useful. Recently, that situation has changed. SeL4 is an open-source operating system microkernel efficient enough to be used in a wide range of practical applications. Its designers proved it to be fully functionally correct, ensuring the absence of buffer overflows, null pointer exceptions, use-after-free errors, etc., and guaranteeing integrity and confidentiality. The CompCert Verifying C Compiler maps source C programs to provably equivalent assembly language, ensuring the absence of exploitable bugs in the compiler. A number of factors have enabled this revolution, including faster processors, increased automation, more extensive infrastructure, specialized logics and the decision to co-develop code and correctness proofs rather than verify existing artefacts. In this paper, we explore the promise and limitations of current formal-methods techniques. We discuss these issues in the context of DARPA’s HACMS program, which had as its goal the creation of high-assurance software for vehicles, including quadcopters, helicopters and automobiles. This article is part of the themed issue ‘Verified trustworthy software systems’. PMID:28871050
Protecting ICS Systems Within the Energy Sector from Cyber Attacks
NASA Astrophysics Data System (ADS)
Barnes, Shaquille
Advance persistent threat (APT) groups are continuing to attack the energy sector through cyberspace, which poses a risk to our society, national security, and economy. Industrial control systems (ICSs) are not designed to handle cyber-attacks, which is why asset owners need to implement the correct proactive and reactive measures to mitigate the risk to their ICS environments. The Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) responded to 290 incidents for fiscal year 2016, where 59 of those incidents came from the Energy Sector. APT groups know how vulnerable energy sector ICS systems are and the destruction they can cause when they go offline such as loss of production, loss of life, and economic impact. Defending against APT groups requires more than just passive controls such as firewalls and antivirus solutions. Asset owners should implement a combination of best practices and active defense in their environment to defend against APT groups. Cyber-attacks against critical infrastructure will become more complex and harder to detect and respond to with traditional security controls. The purpose of this paper was to provide asset owners with the correct security controls and methodologies to help defend against APT groups.
The HACMS program: using formal methods to eliminate exploitable bugs.
Fisher, Kathleen; Launchbury, John; Richards, Raymond
2017-10-13
For decades, formal methods have offered the promise of verified software that does not have exploitable bugs. Until recently, however, it has not been possible to verify software of sufficient complexity to be useful. Recently, that situation has changed. SeL4 is an open-source operating system microkernel efficient enough to be used in a wide range of practical applications. Its designers proved it to be fully functionally correct, ensuring the absence of buffer overflows, null pointer exceptions, use-after-free errors, etc., and guaranteeing integrity and confidentiality. The CompCert Verifying C Compiler maps source C programs to provably equivalent assembly language, ensuring the absence of exploitable bugs in the compiler. A number of factors have enabled this revolution, including faster processors, increased automation, more extensive infrastructure, specialized logics and the decision to co-develop code and correctness proofs rather than verify existing artefacts. In this paper, we explore the promise and limitations of current formal-methods techniques. We discuss these issues in the context of DARPA's HACMS program, which had as its goal the creation of high-assurance software for vehicles, including quadcopters, helicopters and automobiles.This article is part of the themed issue 'Verified trustworthy software systems'. © 2017 The Authors.
A Green Prison: The Santa Rita Jail Campus Microgrid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marnay, Chris; DeForest, Nicholas; Lai, Judy
2012-01-22
A large microgrid project is nearing completion at Alameda County’s twenty-two-year-old 45 ha 4,000-inmate Santa Rita Jail, about 70 km east of San Francisco. Often described as a green prison, it has a considerable installed base of distributed energy resources (DER) including an eight-year old 1.2 MW PV array, a five-year old 1 MW fuel cell with heat recovery, and considerable efficiency investments. A current US$14 M expansion adds a 2 MW-4 MWh Li-ion battery, a static disconnect switch, and various controls upgrades. During grid blackouts, or when conditions favor it, the Jail can now disconnect from the grid andmore » operate as an island, using the on-site resources described together with its back-up diesel generators. In other words, the Santa Rita Jail is a true microgrid, or μgrid, because it fills both requirements, i.e. it is a locally controlled system, and it can operate both grid connected and islanded. The battery’s electronics includes Consortium for Electric Reliability Technology (CERTS) Microgrid technology. This enables the battery to maintain energy balance using droops without need for a fast control system.« less
NASA Astrophysics Data System (ADS)
Nazé, Yaël
2006-03-01
Qui détient le record des découvertes de comètes ? Une femme. Qui a permis de comprendre comment est organisée la population des étoiles ? Une femme. Qui a découvert la loi permettant d'arpenter l'Univers, a trouvé des phares dans l'espace, a compris le fonctionnement des forges stellaires et a bouleversé notre vision de l'Univers ? Encore et toujours une femme... Pourtant, quand on doit citer un astronome -- historique -- au hasard, on pense le plus souvent -- des hommes : Ptolémée, Galilée, Copernic ou, plus près de nous par exemple, Hubble. Certes, au cours des siècles, les femmes n'ont guère eu accès aux sciences en général et -- l'astronomie en particulier mais ce n'est pas une raison pour croire en l'absence totale de contributions dues au beau sexe ! C'est ce que dévoile ici l'auteur. Loin de toute forme de féminisme enragé, on suivra le parcours de quelques scientifiques importantes qui ont par hasard en commun une même particularité : leur sexe.
New Approaches to Tsunami Hazard Mitigation Demonstrated in Oregon
NASA Astrophysics Data System (ADS)
Priest, G. R.; Rizzo, A.; Madin, I.; Lyles Smith, R.; Stimely, L.
2012-12-01
Oregon Department of Geology and Mineral Industries and Oregon Emergency Management collaborated over the last four years to increase tsunami preparedness for residents and visitors to the Oregon coast. Utilizing support from the National Tsunami Hazards Mitigation Program (NTHMP), new approaches to outreach and tsunami hazard assessment were developed and then applied. Hazard assessment was approached by first doing two pilot studies aimed at calibrating theoretical models to direct observations of tsunami inundation gleaned from the historical and prehistoric (paleoseismic/paleotsunami) data. The results of these studies were then submitted to peer-reviewed journals and translated into 1:10,000-12,000-scale inundation maps. The inundation maps utilize a powerful new tsunami model, SELFE, developed by Joseph Zhang at the Oregon Health & Science University. SELFE uses unstructured computational grids and parallel processing technique to achieve fast accurate simulation of tsunami interactions with fine-scale coastal morphology. The inundation maps were simplified into tsunami evacuation zones accessed as map brochures and an interactive mapping portal at http://www.oregongeology.org/tsuclearinghouse/. Unique in the world are new evacuation maps that show separate evacuation zones for distant versus locally generated tsunamis. The brochure maps explain that evacuation time is four hours or more for distant tsunamis but 15-20 minutes for local tsunamis that are invariably accompanied by strong ground shaking. Since distant tsunamis occur much more frequently than local tsunamis, the two-zone maps avoid needless over evacuation (and expense) caused by one-zone maps. Inundation mapping for the entire Oregon coast will be complete by ~2014. Educational outreach was accomplished first by doing a pilot study to measure effectiveness of various approaches using before and after polling and then applying the most effective methods. In descending order, the most effective methods were: (1) door-to-door (person-to-person) education, (2) evacuation drills, (3) outreach to K-12 schools, (4) media events, and (5) workshops targeted to key audiences (lodging facilities, teachers, and local officials). Community organizers were hired to apply these five methods to clusters of small communities, measuring performance by before and after polling. Organizers were encouraged to approach the top priority, person-to-person education, by developing Community Emergency Response Teams (CERT) or CERT-like organizations in each community, thereby leaving behind a functioning volunteer-based group that will continue the outreach program and build long term resiliency. One of the most effective person-to-person educational tools was the Map Your Neighborhood program that brings people together so they can sketch the basic layout of their neighborhoods to depict key earthquake and tsunami hazards and mitigation solutions. The various person-to-person volunteer efforts and supporting outreach activities are knitting communities together and creating a permanent culture of tsunami and earthquake preparedness. All major Oregon coastal population centers will have been covered by this intensive outreach program by ~2014.
NASA Astrophysics Data System (ADS)
Artous, Sébastien; Bombardier, Pierre; Derrough, Samir; Locatelli, Dominique; Nobile, Pierre; Durand, Catherine
2013-04-01
The implementation in many products of manufactured nanoparticles is in strong growth and raises new questions. For this purpose, the CEA - NanoSafety Platform is developing various research topics for health and safety, environment and nanoparticles exposure in professional activities. The working group Nano-CERT/MTD, driven by INERIS, federates actors of the sector: experts, research organizations, industrial users and manufacturers of collective protection. The main activity of this group is to establish specific guidelines or a voluntary certification of collective protection, at a national scale, but with the possibility of a further extension at an European level. The group aims to establish an experimental protocol of certification to characterize collective protections for workers faced with nanomaterials potential exposure. The NanoSafety Platform provides in this presentation a method of collective protection characterization based on the developments in nanoparticles metrology and on the study of existing standards and practices in related areas (chemicals, dust, microbiological and nuclear). This study presents the results obtained during the experimental characterization of a potential nanoparticles transfer in a prototype laboratory fume hood by the use of a particulate tracer of sodium-fluorescein. The efficiency of the equipment and more specifically the efficiency of dynamical air barrier is evaluated, with the experimental results, by calculating the backward diffusion coefficient.
CERT tribal internship program. Final intern report: Duane Gopher, 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Rocky Boy Indian Reservation in north-central Montana has had difficulty in establishing a dependable source of drinking water. In 1993, due to a water shortage on the Rocky Boy Reservation, the Chippewa-Cree Council began negotiating water rights with the State of Montana in order to construct a pipeline that would pump water from an off-reservation source to reservation homes. The proposed plan is to pipe water from the Tiber Dam, located approximately 53 miles west, to the Rocky Boy Indian Reservation for treatment and distribution. The purpose of this internship was to initiate a ground water investigation on themore » Rocky Boy Reservation by writing a report and submitting it to the Tribe. The intern undertook this project because he felt there was no need for an expensive pipeline and from familiarity with the Reservation, thought a dependable supply of drinking water may already exist on the Reservation. The intern obtained topographic maps from the USGS, requested well logs, conducted a literature survey, and requested planimetric maps from the Montana Bureau of Mines. The preliminary ground water report has been completed, but final results of the investigation are dependent upon the review by the Rocky Boy Tribal Council. This intern report contains biographical data on the intern and his mentor, as well as the completed preliminary report submitted to the Tribal Council.« less
NASA Astrophysics Data System (ADS)
Padgett, Barbara Nicole
Recently developed Al-Li-Cu alloys show great potential for implementation in the aerospace industry because of the attractive mix of good mechanical properties and low density. AA2099 is an Al-Li-Cu alloy with the following composition Al-2.69wt%Cu-1.8wt%Li-0.6wt%Zn-0.3wt%Mg-0.3wt%Mn-0.08wt%Zr. The environmental assisted cracking and localized corrosion behavior of the AA2099 was investigated in this thesis. The consequences of uncontrolled grain boundary precipitation via friction stir welding on the stress corrosion cracking (SCC) behavior of AA2099 was investigated first. Using constant extension rate testing, intergranular corrosion immersion experiments, and potentiodynamic scans, the heat-affected zone on the trailing edge of the weld (HTS) was determined to be most susceptible of the weld zones. The observed SCC behavior for the HTS was linked to the dissolution of an active phase (Al2CuLi, T1) populating the grain boundary. It should be stated that the SCC properties of AA2099 in the as-received condition were determined to be good. Focus was then given to the electrochemical behavior of precipitate phases that may occupy grain and sub-grain boundaries in AA2099. The grain boundary micro-chemistry and micro-electrochemistry have been alluded to within the literature as having significant influence on the SCC behavior of Al-Li-Cu alloys. Major precipitates found in this alloy system are T1 (Al 2CuLi), T2 (Al7.5Cu4Li), T B (Al6CuLi3), and theta (Al2 Cu). These phases were produced in bulk form so that the electrochemical nature of each phase could be characterized. It was determined T1 was most active electrochemically and theta was least. When present on grain boundaries in the alloy, electrochemical behavior of the individual precipitates aligned with the observed corrosion behavior of the alloy (e.g. TB was accompanied by general pitting corrosion and T 1 was accompanied by intergranular corrosion attack). In addition to the electrochemical behavior of the above-mentioned intermetallics, the phenomenon of Zn substituting for Cu in T1 was also studied. It was determined that for Zn substitutions up to 8.4wt%, improved corrosion behavior of T 1 would occur by dealloying of Zn and Li. Lastly, isothermal aging treatments at 160°C and 190°C were conducted to vary the grain boundary structures in a systematic way. The SCC behaviors for the under-aged, peak-aged, and over-aged condition were studied using CERT and alternate immersion testing at each temperature. The severely under-aged condition (≤ 9 hours) at 160°C proved to have poorest SCC resistance. The over-aged condition at 160°C (≥ 24 hours) also had degraded SCC resistance. In contrast the 190°C isothermal aging condition produced better SCC resistance than 160°C isothermal aging temperature for all conditions. The differences in behavior were linked to the species populating the grain boundaries in each isothermal aging condition (T2 at 190°C and T1 at 160°C).
Dead Cert: Measuring Cell Death.
Crowley, Lisa C; Marfell, Brooke J; Scott, Adrian P; Boughaba, Jeanne A; Chojnowski, Grace; Christensen, Melinda E; Waterhouse, Nigel J
2016-12-01
Many cells in the body die at specific times to facilitate healthy development or because they have become old, damaged, or infected. Defects in cells that result in their inappropriate survival or untimely death can negatively impact development or contribute to a variety of human pathologies, including cancer, AIDS, autoimmune disorders, and chronic infection. Cell death may also occur following exposure to environmental toxins or cytotoxic chemicals. Although this is often harmful, it can be beneficial in some cases, such as in the treatment of cancer. The ability to objectively measure cell death in a laboratory setting is therefore essential to understanding and investigating the causes and treatments of many human diseases and disorders. Often, it is sufficient to know the extent of cell death in a sample; however, the mechanism of death may also have implications for disease progression, treatment, and the outcomes of experimental investigations. There are a myriad of assays available for measuring the known forms of cell death, including apoptosis, necrosis, autophagy, necroptosis, anoikis, and pyroptosis. Here, we introduce a range of assays for measuring cell death in cultured cells, and we outline basic techniques for distinguishing healthy cells from apoptotic or necrotic cells-the two most common forms of cell death. We also provide personal insight into where these assays may be useful and how they may or may not be used to distinguish apoptotic cell death from other death modalities. © 2016 Cold Spring Harbor Laboratory Press.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 11 2011-04-01 2011-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 11 2014-04-01 2014-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 11 2013-04-01 2013-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 11 2012-04-01 2012-04-01 false Test rate. 1.1274-4 Section 1.1274-4 Internal... TAXES (CONTINUED) Special Rules for Determining Capital Gains and Losses § 1.1274-4 Test rate. (a) Determination of test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in...
Test Report of Special Form Qualification Testing for the ORNL U ZipCan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, Oscar A.
This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSImore » N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.« less
NASA Astrophysics Data System (ADS)
Wen, Zhang; Zhan, Hongbin; Wang, Quanrong; Liang, Xing; Ma, Teng; Chen, Chen
2017-05-01
Actual field pumping tests often involve variable pumping rates which cannot be handled by the classical constant-rate or constant-head test models, and often require a convolution process to interpret the test data. In this study, we proposed a semi-analytical model considering an exponentially decreasing pumping rate started at a certain (higher) rate and eventually stabilized at a certain (lower) rate for cases with or without wellbore storage. A striking new feature of the pumping test with an exponentially decayed rate is that the drawdowns will decrease over a certain period of time during intermediate pumping stage, which has never been seen before in constant-rate or constant-head pumping tests. It was found that the drawdown-time curve associated with an exponentially decayed pumping rate function was bounded by two asymptotic curves of the constant-rate tests with rates equaling to the starting and stabilizing rates, respectively. The wellbore storage must be considered for a pumping test without an observation well (single-well test). Based on such characteristics of the time-drawdown curve, we developed a new method to estimate the aquifer parameters by using the genetic algorithm.
77 FR 75896 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-26
...-11213, Notice No. 16] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013... from FRA's Management Information System, the rail industry's random drug testing positive rate has... therefore determined that the minimum annual random drug testing rate for the period January 1, 2013...
Davies, K; Davis, G; Barbut, F; Eckert, C; Petrosillo, N; Wilcox, M H
2016-12-01
Lack of standardised Clostridium difficile testing is a potential confounder when comparing infection rates. We used an observational, systematic, prospective large-scale sampling approach to investigate variability in C. difficile sampling to understand C. difficile infection (CDI) incidence rates. In-patient and institutional data were gathered from 60 European hospitals (across three countries). Testing methodology, testing/CDI rates and case profiles were compared between countries and institution types. The mean annual CDI rate per hospital was lowest in the UK and highest in Italy (1.5 vs. 4.7 cases/10,000 patient bed days [pbds], p < 0.001). The testing rate was highest in the UK compared with Italy and France (50.7/10,000 pbds vs. 31.5 and 30.3, respectively, p < 0.001). Only 58.4 % of diarrhoeal samples were tested for CDI across all countries. Overall, only 64 % of hospitals used recommended testing algorithms for laboratory testing. Small hospitals were significantly more likely to use standalone toxin tests (SATTs). There was an inverse correlation between hospital size and CDI testing rate. Hospitals using SATT or assays not detecting toxin reported significantly higher CDI rates than those using recommended methods, despite testing similar testing frequencies. These data are consistent with higher false-positive rates in such (non-recommended) testing scenarios. Cases in Italy and those diagnosed by SATT or methods NOT detecting toxin were significantly older. Testing occurred significantly earlier in the UK. Assessment of testing practice is paramount to the accurate interpretation and comparison of CDI rates.
Outpatient use of cardiovascular drugs during pregnancy.
Andrade, Susan E; Raebel, Marsha A; Brown, Jeffrey; Lane, Kimberly; Livingston, James; Boudreau, Denise; Rolnick, Sharon J; Roblin, Douglas; Smith, David H; Dal Pan, Gerald J; Scott, Pamela E; Platt, Richard
2008-03-01
To provide information on the prevalence of use of cardiovascular drugs, some of which may have fetotoxic or teratogenic effects, in the outpatient setting among pregnant women in the United States. A retrospective study was conducted using the automated databases of seven health plans participating in the HMO Research Network Center for Education and Research on Therapeutics (CERT). Women who delivered an infant from 1 January 2001 to 31 December 2005 were identified. Cardiovascular drug use was evaluated assuming a gestational duration of 270 days. During the period 2001 through 2005, 118,935 deliveries were identified that met the criteria for study; 3.1% of women (N = 3672) were dispensed an antihypertensive medication and 0.12% of women (N = 146) were dispensed an antihyperlipidemic medication at any time during pregnancy. The most common antihypertensive drugs dispensed during pregnancy were nifedipine (1219 deliveries; 1.0%), methyldopa (961 deliveries; 0.8%), atenolol (593 deliveries; 0.5%), and labetalol (576 deliveries; 0.5%). Overall, 134 women (0.11%) received an angiotensin converting enzyme (ACE) inhibitor and 7 women (0.006%) received an angiotensin II receptor blocker (ARB) during pregnancy. Statins were the most commonly dispensed antihyperlipidemic drugs (71 deliveries; 0.06%). The prevalence of use of cardiovascular drugs that are suspected to be fetotoxic or teratogenic (ACE inhibitors, ARBs, and statins) was low in this cohort of pregnant women. Differing patterns of use across health plans suggests that further research is needed to evaluate the potential differential effects of cardiovascular drugs to assist prescribers and patients in making informed treatment decisions. Copyright 2008 John Wiley & Sons, Ltd.
The importance of news media in pharmaceutical risk communication: proceedings of a workshop.
Mebane, Felicia E
2005-05-01
In response to mass media's role in the national and global system of pharmaceutical risk communication, the Centers for Education and Research on Therapeutics (CERTs) convened a 'think tank' session on the 'Importance of Media in Pharmaceutical Risk Communication'. Prominent journalists and experts from the pharmaceutical industry, academia, medical practice and government were invited to consider the benefits and challenges of improving the way we communicate the benefits and risks of therapeutics via mass media, especially news media. Workshop discussions revealed a paucity of systematic research directed towards understanding how and why news media report on therapeutic risk, the impact of this coverage and how coverage can be improved. Consequently, participants produced a research agenda capturing the key aspects of the flow of information around this topic, including the meaning of risk, how news audiences process and use therapeutic risk information in the news, how and why news organizations report on therapeutic risk, and the role and impact of the pharmaceutical industry, government officials and academic researchers as sources of therapeutic risk information. The workshop ended with a discussion on action items addressing what news professionals, representatives of regulatory agencies and the medical products industry, and academic researchers can and should do to enable news media to effectively report therapeutic risk information. In sum, this proceedings report provides an outline for developing mass media risk communication research, influencing the practices of journalists and expert sources and ultimately, improving the quality of the public's life. Copyright (c) 2004 John Wiley & Sons, Ltd.
Temperature and Atomic Oxygen Effects on Helium Leak Rates of a Candidate Main Interface Seal
NASA Technical Reports Server (NTRS)
Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.
2011-01-01
Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two vehicles, while docked, to prevent the escape of breathable air from the vehicles and into the vacuum of space. Leak tests completed at nominal temperatures of -30, 20, and 50 C on untreated and atomic oxygen (AO) exposed test samples were examined to determine the influence of both test temperature and AO exposure on the performance of the composite seal assembly. Results obtained for untreated seal samples showed leak rates which increased with increased test temperature. This general trend was not observed in tests of the AO exposed specimens. Initial examination of collected test data suggested that AO exposure resulted in higher helium leak rates, however, further analysis showed that the differences observed in the 20 and 50 C tests between the untreated and AO exposed samples were within the experimental error of the test method. Lack of discernable trends in the test data prevented concrete conclusions about the effects of test temperature and AO exposure on helium leak rates of the candidate seal design from being drawn. To facilitate a comparison of the current test data with results from previous leak tests using air as the test fluid, helium leak rates were converted to air leak rates using standard conversion factors for viscous and molecular flow. Flow rates calculated using the viscous flow conversion factor were significantly higher than the experimental air leakage values, whereas values calculated using the molecular flow conversion factor were significantly lower than the experimentally obtained air leak rates. The difference in these sets of converted flow rates and their deviation from the experimentally obtained air leak rate data suggest that neither conversion factor can be used alone to accurately convert helium leak rates to equivalent air leak rates for the test seals evaluated in this study; other leak phenomena, including permeation, must also be considered.
Fitness for duty in the nuclear power industry. Annual summary of program performance reports
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silbernagel, M.; Brichoux, J.; Durbin, N.
This report summarizes the data from the semiannual reports on fitness-for-duty programs submitted to the NRC by utilities for two reporting periods: January 1-June 30, 1995, and July 1 -December 31, 1995. During 1995, licensees reported that they had conducted 150,121 tests for the presence of illegal drugs and alcohol. Of these tests, 1,476 (.98%) were confirmed positive. The majority of positive test results (1, 122) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 180 positive tests from random testing and 139 positive tests from for-cause testing. Follow-up testing ofmore » workers who had previously tested positive resulted in 35 positive tests. For-cause testing resulted in the highest percentage of positive tests; about 18 percent of for-cause tests were positive. This compares with a positive test rate of 1.41 percent of pre-access tests and .27 percent of random tests. The positive test rate for workers with unescorted access was .50 percent. Positive test rates also varied by category of worker. When all types of tests are combined, short-term contractor personnel had the highest positive test rate at 1.44 percent. Licensee employees and long-term contractors had lower combined positive test rates (.34% and .40%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (53.08%), followed by cocaine (24.24%) and alcohol (17.17%). The overall positive test rate for 1995 (.98%) was higher than in 1994 (.84%). Several factors had an impact on the positive test rate across test categories for 1994 and 1995 compared to previous years. These factors include the NRC`s reduction in the mandatory random testing rate from 100 percent to 50 percent, effective in 1994, and initiatives by licensees such as lowered marijuana screening cutoff levels and reported improvements in licensees ability to detect subversion of the process.« less
Scholes, Delia; Satterwhite, Catherine L; Yu, Onchee; Fine, David; Weinstock, Hillard; Berman, Stuart
2012-02-01
Given recent increasing case rates of Chlamydia trachomatis infection, we evaluated trends in chlamydia rates and related health outcomes in women and men aged 15 to 44 years who were enrolled in a Pacific Northwest health plan. We identified chlamydia, pelvic inflammatory disease (PID), ectopic pregnancy, and male urethritis cases occurring annually during 1997-2007 using computerized health plan databases, calculating rates per 100,000 person-years (py) by gender and 5-year age groups. We also calculated annual chlamydia testing rates. In women, chlamydia testing rates increased by approximately 23% (220 tests per 1000 py in 1997 to 270 tests per 1000 in 2007). Chlamydia diagnosis rates rose from 449 cases/100,000 py in 1997 to 806/100,000 in 2007, a 79% increase (P = 0.01). Increases were greatest during 2005-2007, also the period of major conversion to nucleic acid amplification test. PID rates in this interval declined steadily from 823 cases/100,000 py to 473/100,000 (P < 0.01). Ectopic pregnancy rates remained unchanged. In men, chlamydia testing rates increased nearly 3.5-fold, from 12 to 42 tests per 1000 py. Chlamydia rates for men also rose significantly throughout the study interval (from 91 cases/100,000 py to 218/100,000; P < 0.01) as did urethritis diagnosis rates (P < 0.01). Between 1997 and 2007, annual health plan chlamydia rates increased significantly for both women and men. These trends may be due in part to increased testing rates and increased use of more sensitive tests, but they likely do not explain the increased urethritis rates. During this same interval, we observed steady declines in PID rates, consistent with other national data sources.
78 FR 4855 - Random Drug Testing Rate for Covered Crewmembers
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-23
... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2013 minimum random drug testing rate at 25 percent of...
76 FR 79204 - Random Drug Testing Rate for Covered Crewmembers
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-21
... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2012 minimum random drug testing rate at 50 percent of...
76 FR 1448 - Random Drug Testing Rate for Covered Crewmembers
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-10
... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2009-0973] Random Drug Testing Rate for Covered Crewmembers AGENCY: Coast Guard, DHS. ACTION: Notice of minimum random drug testing rate. SUMMARY: The Coast Guard has set the calendar year 2011 minimum random drug testing rate at 50 percent of...
Casillas, Jean-Marie; Joussain, Charles; Gremeaux, Vincent; Hannequin, Armelle; Rapin, Amandine; Laurent, Yves; Benaïm, Charles
2015-02-01
To develop a new predictive model of maximal heart rate based on two walking tests at different speeds (comfortable and brisk walking) as an alternative to a cardiopulmonary exercise test during cardiac rehabilitation. Evaluation of a clinical assessment tool. A Cardiac Rehabilitation Department in France. A total of 148 patients (133 men), mean age of 59 ±9 years, at the end of an outpatient cardiac rehabilitation programme. Patients successively performed a 6-minute walk test, a 200 m fast-walk test (200mFWT), and a cardiopulmonary exercise test, with measure of heart rate at the end of each test. An all-possible regression procedure was used to determine the best predictive regression models of maximal heart rate. The best model was compared with the Fox equation in term of predictive error of maximal heart rate using the paired t-test. Results of the two walking tests correlated significantly with maximal heart rate determined during the cardiopulmonary exercise test, whereas anthropometric parameters and resting heart rate did not. The simplified predictive model with the most acceptable mean error was: maximal heart rate = 130 - 0.6 × age + 0.3 × HR200mFWT (R(2) = 0.24). This model was superior to the Fox formula (R(2) = 0.138). The relationship between training target heart rate calculated from measured reserve heart rate and that established using this predictive model was statistically significant (r = 0.528, p < 10(-6)). A formula combining heart rate measured during a safe simple fast walk test and age is more efficient than an equation only including age to predict maximal heart rate and training target heart rate. © The Author(s) 2014.
1986-09-01
HYPOTHESIS TEST .................... 20 III. TIME TO GET RATED TWO FACTOR ANOVA RESULTS ......... 23 IV. TIME TO GET RATED TUKEY’S PAIRED COvfl’PARISON... TEST RESULTS A ............................................ 24 V. TIME TO GET RATED TUKEY’S PAIRED COMPARISON TEST RESULTS B...25 VI. SINGLE FACTOR ANOVA HYPOTHESIS TEST #I............... 27 VII. AT: TIME TO GET RATED ANOVA TEST RESULTS ............. 30
The Application of Stress-Relaxation Test to Life Assessment of T911/T22 Weld Metal
NASA Astrophysics Data System (ADS)
Cao, Tieshan; Zhao, Jie; Cheng, Congqian; Li, Huifang
2016-03-01
A dissimilar weld metal was obtained through submerged arc welding of a T911 steel to a T22 steel, and its creep property was explored by stress-relaxation test assisted by some conventional creep tests. The creep rate information of the stress-relaxation test was compared to the minimum and the average creep rates of the conventional creep test. Log-log graph showed that the creep rate of the stress-relaxation test was in a linear relationship with the minimum creep rate of the conventional creep test. Thus, the creep rate of stress-relaxation test could be used in the Monkman-Grant relation to calculate the rupture life. The creep rate of the stress-relaxation test was similar to the average creep rate, and thereby the rupture life could be evaluated by a method of "time to rupture strain." The results also showed that rupture life which was assessed by the Monkman-Grant relation was more accurate than that obtained through the method of "time to rupture strain."
King, Thomas C; Upfal, Mark; Gottlieb, Andrew; Adamo, Philip; Bernacki, Edward; Kadlecek, Chris P; Jones, Jeffrey G; Humphrey-Carothers, Frances; Rielly, Albert F; Drewry, Pamela; Murray, Kathy; DeWitt, Marcie; Matsubara, Janet; O'Dea, Louis; Balser, John; Wrighton-Smith, Peter
2015-08-01
Interferon-γ release assays have significant advantages over tuberculin skin testing in many clinical situations. However, recent studies have called into question their reliability in serial testing of healthcare workers because of reportedly high rates of positivity and high conversion/reversion rates on retesting. To define the performance characteristics of the T-SPOT.TB test, an interferon-γ release assay, during serial screening programs of healthcare workers at 19 U.S. hospitals. A total of 42,155 T-SPOT.TB test results from healthcare workers at 19 geographically diverse hospitals obtained for routine tuberculosis screening programs were analyzed to determine the rates of positivity, reversion, and conversion in serial testing data. In 19,630 evaluable serial pairs from 16,076 healthcare workers, the mean test positivity rate was 2.3% (range, 0.0-27.4%). The mean conversion rate was 0.8% (range, 0.0-2.5%), and the mean reversion rate was 17.6%. Positivity and conversion rates correlated with known tuberculosis risk factors including age and sex. The observed specificity of the T-SPOT.TB test was at least 98.6%. The high concordance and test completion rates in this study suggest that the T-SPOT.TB test is a reliable tool for healthcare worker serial screening. As expected, the observed positivity rates were lower compared with the tuberculin skin test, likely reflecting the higher specificity of this test. Furthermore, the observed rates of conversion were low and significantly correlated with the geographic incidence of tuberculosis. Our findings suggest that the T-SPOT.TB test is an accurate and reliable way to screen healthcare workers.
75 FR 76078 - Pipeline Safety: Random Drug Testing Rate
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
... PHMSA-2010-0323] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... testing. SUMMARY: PHMSA has determined that the minimum random drug testing rate for covered employees... employees for random drug testing. Pursuant to 49 CFR 199.105(c)(2), (3), and (4), the PHMSA Administrator's...
Bradley, Steven M; Hess, Edward; Winchester, David E; Sussman, Jeremy B; Aggarwal, Vikas; Maddox, Thomas M; Barón, Anna E; Rumsfeld, John S; Ho, P Michael
2015-09-01
Stress testing after percutaneous coronary intervention (PCI) in fee-for-service settings is common and rates vary by hospital. Rates of stress testing after PCI within integrated healthcare systems, such as the Veterans Affairs (VA) are unknown. We evaluated all VA patients who underwent PCI from October 2007 through June 2010. To avoid the influence of Medicare eligibility on rates of stress testing use in the VA, we excluded Medicare eligible patients during the follow-up period. Hospital-level variation in risk-standardized rates of stress testing and the association with 1-year mortality and myocardial infarction was determined from Markov chain Monte Carlo methods. Among 10 293 patients undergoing PCI at 55 VA hospitals, 2239 (21.8%) had a stress test performed within 1 year of PCI and 3902 (37.9%) within 2 years. Most stress tests after PCI were performed with nuclear imaging (79.8%). The hospital-level risk-standardized rate of stress testing differed significantly from the average at 14 hospitals, with 8 (14.5%) hospitals significantly below and 6 (10.9%) hospitals significantly above the average stress testing rate. Hospital-level risk-standardized stress testing rates were not significantly correlated with risk-standardized mortality (Spearman ρ=-0.24; P=0.08) or myocardial infarction rates (Spearman ρ=0.20; P=0.14). In the VA, nearly 40% of patients underwent stress testing in the 2 years after PCI, which is a third less than published studies from other healthcare systems. However, stress testing rates varied across VA hospitals, suggesting opportunities to optimize the use of stress testing are still present in integrated healthcare systems. © 2015 American Heart Association, Inc.
26 CFR 1.483-3 - Test rate of interest applicable to a contract.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 6 2010-04-01 2010-04-01 false Test rate of interest applicable to a contract... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Adjustments § 1.483-3 Test rate of interest applicable to a contract. (a) General rule. For purposes of section 483, the test rate of interest for a contract is the...
Ultra High Strain Rate Nanoindentation Testing.
Sudharshan Phani, Pardhasaradhi; Oliver, Warren Carl
2017-06-17
Strain rate dependence of indentation hardness has been widely used to study time-dependent plasticity. However, the currently available techniques limit the range of strain rates that can be achieved during indentation testing. Recent advances in electronics have enabled nanomechanical measurements with very low noise levels (sub nanometer) at fast time constants (20 µs) and high data acquisition rates (100 KHz). These capabilities open the doors for a wide range of ultra-fast nanomechanical testing, for instance, indentation testing at very high strain rates. With an accurate dynamic model and an instrument with fast time constants, step load tests can be performed which enable access to indentation strain rates approaching ballistic levels (i.e., 4000 1/s). A novel indentation based testing technique involving a combination of step load and constant load and hold tests that enables measurement of strain rate dependence of hardness spanning over seven orders of magnitude in strain rate is presented. A simple analysis is used to calculate the equivalent uniaxial response from indentation data and compared to the conventional uniaxial data for commercial purity aluminum. Excellent agreement is found between the indentation and uniaxial data over several orders of magnitude of strain rate.
NASA Astrophysics Data System (ADS)
Majidi, Omid; Jahazi, Mohammad; Bombardier, Nicolas; Samuel, Ehab
2017-10-01
The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.
Beardsley, Chris; Egerton, Tim; Skinner, Brendon
2016-01-01
Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.
75 FR 17169 - Nextera Energy Duane Arnold, LLC, Duane Arnold Energy Center; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
... leakage from the overall integrated leak rate test measurement. Main steam leakage includes leakage... integrated leakage rate (Type A) test measurement and from the sum of the leakage rates from local leakage... leakage rate (Type A) test [[Page 17170
Campbell, Stephen M; Fuat, Ahmet; Summerton, Nick; Lancaster, Neil; Hobbs, FD Richard
2011-01-01
Background Some UK GPs are acquiring access to natriuretic peptide (NP) testing or echocardiography as diagnostic tests for heart failure. This study developed appropriateness ratings for the diagnostic application of these tests in routine general practice. Aim To develop appropriateness ratings for the diagnostic application of NP testing or echocardiography for heart failure in general practice. Design and setting An appropriateness ratings evaluation in UK general practice. Method Four presenting symptoms (cough, bilateral ankle swelling, dyspnoea, fatigue), three levels of risk of cardiovascular disease (low, intermediate, high), and dichotomous categorisations of cardiovascular/chest examination and electrocardiogram result, were used to create 540 appropriateness scenarios for patients in whom NP testing or echocardiography might be considered. These were rated by a 10-person expert panel, consisting of GPs and GPs with specialist interests in cardiology, in a two-round RAND Appropriateness Method. Results Onward referral for NP testing or echocardiography was rated as an appropriate next step in 217 (40.2%) of the 540 scenarios; in 194 (35.9%) it was rated inappropriate. The ratings also show where NP testing or echocardiography were ranked as equivalent next steps and when one test was seen as the more appropriate than the other. Conclusion NP testing should be the routine test for suspected heart failure where referral for diagnostic testing is considered appropriate. An abnormal electrocardiogram status makes referral to echocardiography an accompanying, or more appropriate, next step alongside NP testing, especially in the presence of dyspnoea. Abnormal NP testing should subsequently be followed up with referral for echocardiography. PMID:21722451
[Study on the stability of tetrandrine microsphere].
Cheng, Guohu; Luo, Jiabo
2005-05-01
To study the stability of Tetrandrine Microsphere. Higher speed test and room temperature test were adopted to investigate the indexes, such as properties of appearance, amount of medicine loaded, seal rate, seepage rate, microbial stability, etc. Through the test of six months, properties of appearance, amount of medicine loaded, seal rate, seepage rate, microbial stability have not obviously change. But after testing for 6 months with higher temperature, the seal rate was reduced, and the seepage rate was increased. Tetrandrine microsphere is steady under the room temperature condition, but is unstable to hot, and ought to keep in conformity with low-temperature.
Anna, D H; Zellers, E T; Sulewski, R
1998-08-01
ASTM (American Society for Testing and Materials) Method F739-96 specifies a test-cell design and procedures for measuring the permeation resistance of chemical protective clothing. Among the specifications are open-loop collection stream flow rates of 0.050 to 0.150 L/min for a gaseous medium. At elevated temperatures the test must be maintained within 1 degree C of the set point. This article presents a critical analysis of the effect of the collection stream flow rate on the measured permeation rate and on the temperature uniformity within the test cell. Permeation tests were conducted on four polymeric glove materials with 44 solvents at 25 degrees C. Flow rates > 0.5 L/min were necessary to obtain accurate steady-state permeation rate (SSPR) values in 25 percent of the tests. At the lower flow rates the true SSPR typically was underestimated by a factor of two or less, but errors of up to 33-fold were observed. No clear relationship could be established between the need for a higher collection stream flow rate and either the vapor pressure or the permeation rate of the solvent, but test results suggest that poor mixing within the collection chamber was a contributing factor. Temperature gradients between the challenge and collection chambers and between the bottom and the top of the collection chamber increased with the water-bath temperature and the collection stream flow rate. Use of a test cell modified to permit deeper submersion reduced the gradients to < or = 0.5 degrees C. It is recommended that all SSPR measurements include verification of the adequacy of the collection stream flow rate. For testing at nonambient temperatures, the modified test cell described here could be used to ensure temperature uniformity throughout the cell.
Instrument Rating Practical Test Standards for Airplane, Helicopter, Airship
DOT National Transportation Integrated Search
1994-10-01
The Instrument Rating Practical Test Standards (PTS) book has : been published by the Federal Aviation Administration (FAA) to : establish the standards for the instrument rating practical test for : airplanes, helicopters, and airships. FAA inspecto...
ERIC Educational Resources Information Center
Evers, Arne; Sijtsma, Klaas; Lucassen, Wouter; Meijer, Rob R.
2010-01-01
This article describes the 2009 revision of the Dutch Rating System for Test Quality and presents the results of test ratings from almost 30 years. The rating system evaluates the quality of a test on seven criteria: theoretical basis, quality of the testing materials, comprehensiveness of the manual, norms, reliability, construct validity, and…
Improving Accuracy of Influenza-Associated Hospitalization Rate Estimates
Reed, Carrie; Kirley, Pam Daily; Aragon, Deborah; Meek, James; Farley, Monica M.; Ryan, Patricia; Collins, Jim; Lynfield, Ruth; Baumbach, Joan; Zansky, Shelley; Bennett, Nancy M.; Fowler, Brian; Thomas, Ann; Lindegren, Mary L.; Atkinson, Annette; Finelli, Lyn; Chaves, Sandra S.
2015-01-01
Diagnostic test sensitivity affects rate estimates for laboratory-confirmed influenza–associated hospitalizations. We used data from FluSurv-NET, a national population-based surveillance system for laboratory-confirmed influenza hospitalizations, to capture diagnostic test type by patient age and influenza season. We calculated observed rates by age group and adjusted rates by test sensitivity. Test sensitivity was lowest in adults >65 years of age. For all ages, reverse transcription PCR was the most sensitive test, and use increased from <10% during 2003–2008 to ≈70% during 2009–2013. Observed hospitalization rates per 100,000 persons varied by season: 7.3–50.5 for children <18 years of age, 3.0–30.3 for adults 18–64 years, and 13.6–181.8 for adults >65 years. After 2009, hospitalization rates adjusted by test sensitivity were ≈15% higher for children <18 years, ≈20% higher for adults 18–64 years, and ≈55% for adults >65 years of age. Test sensitivity adjustments improve the accuracy of hospitalization rate estimates. PMID:26292017
Enhanced Low Dose Rate Effects in Bipolar Circuits: A New Hardness Assurance Problem for NASA
NASA Technical Reports Server (NTRS)
Johnston, A.; Barnes, C.
1995-01-01
Many bipolar integrated circuits are much more susceptible to ionizing radiation at low dose rates than they are at high dose rates typically used for radiation parts testing. Since the low dose rate is equivalent to that seen in space, the standard lab test no longer can be considered conservative and has caused the Air Force to issue an alert. Although a reliable radiation hardness assurance test has not yet been designed, possible mechanisms for low dose rate enhancement and hardness assurance tests are discussed.
Mansikka, Heikki; Virtanen, Kai; Harris, Don; Simola, Petteri
2016-09-01
Increased task demand will increase the pilot mental workload (PMWL). When PMWL is increased, mental overload may occur resulting in degraded performance. During pilots' instrument flight rules (IFR) proficiency test, PMWL is typically not measured. Therefore, little is known about workload during the proficiency test and pilots' potential to cope with higher task demands than those experienced during the test. In this study, fighter pilots' performance and PMWL was measured during a real IFR proficiency test in an F/A-18 simulator. PMWL was measured using heart rate (HR) and heart rate variation (HRV). Performance was rated using Finnish Air Force's official rating scales. Results indicated that HR and HRV differentiate varying task demands in situations where variations in performance are insignificant. It was concluded that during a proficiency test, PMWL should be measured together with the task performance measurement. Copyright © 2016 Elsevier Ltd. All rights reserved.
Autonomic changes after treatment of agoraphobia with panic attacks.
Roth, W T; Telch, M J; Taylor, C B; Agras, W S
1988-04-01
Twenty-three patients meeting DSM-III criteria for agoraphobia with panic attacks and 14 age-, race-, and sex-matched nonanxious controls were tested in the laboratory and on a test walk in a shopping mall. The patients were tested before and after about 15 weeks of treatment with placebo and exposure therapy, imipramine and exposure therapy, or imipramine and initial antiexposure instructions. Controls were tested twice at a similar interval, but without any treatment. On test day 1, patients compared to controls showed higher average heart rate and skin conductance levels and greater numbers of skin conductance fluctuations in the laboratory, and higher heart rates before and during the test walk. Between pretreatment and posttreatment tests, clinical ratings improved and skin conductance levels decreased in all treatment groups. Heart rate levels in the laboratory, on the other hand, decreased in patients on placebo and rose in patients on imipramine. Thus, imipramine compromises the usefulness of heart rate as a measure of emotional arousal. Higher pretreatment heart rates predicted greater clinical improvement.
Levine, C; Younglove, T; Barth, M
2000-10-01
Recent studies have shown large increases in vehicle emissions when the air conditioner (AC) compressor is engaged. Factors that affect the compressor-on percentage can have a significant impact on vehicle emissions and can also lead to prediction errors in current emissions models if not accounted for properly. During 1996 and 1997, the University of California, Riverside, College of Engineering-Center for Environmental Research and Technology (CE-CERT) conducted a vehicle activity study for the California Air Resources Board (CARB) in the Sacramento, CA, region. The vehicles were randomly selected from all registered vehicles in the region. As part of this study, ten vehicles were instrumented to collect AC compressor on/off data on a second-by-second basis in the summer of 1997. Temperature and humidity data were obtained and averaged on an hourly basis. The ten drivers were asked to complete a short survey about AC operational preferences. This paper examines the effects of temperature, humidity, refrigerant type, and driver preferences on air conditioning compressor activity. Overall, AC was in use in 69.1% of the trips monitored. The compressor was on an average of 64% of the time during the trips. The personal preference settings had a significant effect on the AC compressor-on percentage but did not interact with temperature. The refrigerant types, however, exhibited a differential response across temperature, which may necessitate separate modeling of the R12 refrigerant-equipped vehicles from the R134A-equipped vehicles. It should be noted that some older vehicles do get retrofitted with new compressors that use R134A; however, none of the vehicles in this study had been retrofitted.
Résultats fonctionnels des lésions des tendons fléchisseurs de la main: à propos de 90 cas
Boussakri, Hassan; Azarkane, Mohamad; Elidrissi, Mohamad; Shimi, Mohamad; Elibrahimi, Abdelhalim; Elmrini, Abdelmajid
2013-01-01
Les auteurs rapportent une série de 90 patients, présentant une section tendineuse des fléchisseurs de la main, et suivis avec un recul moyen de 8 mois (min: 2 mois; max: 13 mois). La lésion était localisée dans 12% des cas en zone I, 46% des cas en zone II, 2% en zone III et 25% des cas en zone IV et V. Pour le pouce (13 patients), 10 cas en zone T2 et 3 cas en zone T3. La technique opératoire utilisée était les sutures tendineuses en cadre de Kessler modifié, associée à un surjet épitendineux. Nous avons obtenus 54% de très bons résultats, 34% de résultats moyens et 12% de mauvais résultats. Pour le pouce les résultats semble moins bons avec un taux de résultats médiocre de 48%. Certes les chiffres de cette série sont moins bons que ceux des autres séries publiées dans la littérature. Les facteurs influençant les résultats sont d'abord l'utilisation d'immobilisation postopératoire systématique ainsi que le mécanisme d'agression, et la localisation à la zone II et au pouce. Les complications mécaniques sont représentées par 7% de rupture, toutes au niveau de pouce, et 31% des adhérences tendineuses (soit 30 cas), dont 19 en zone II, l'infections (22%) et 4% des cas d'algodystrophies. PMID:23847698
NASA Astrophysics Data System (ADS)
Kacarab, Mary; Li, Lijie; Carter, William P. L.; Cocker, David R., III
2016-04-01
Two different surrogate mixtures of anthropogenic and biogenic volatile organic compounds (VOCs) were developed to study secondary organic aerosol (SOA) formation at atmospheric reactivities similar to urban regions with varying biogenic influence levels. Environmental chamber simulations were designed to enable the study of the incremental aerosol formation from select anthropogenic (m-Xylene, 1,2,4-Trimethylbenzene, and 1-Methylnaphthalene) and biogenic (α-pinene) precursors under the chemical reactivity set by the two different surrogate mixtures. The surrogate reactive organic gas (ROG) mixtures were based on that used to develop the maximum incremental reactivity (MIR) factors for evaluation of O3 forming potential. Multiple incremental aerosol formation experiments were performed in the University of California Riverside (UCR) College of Engineering Center for Environmental Research and Technology (CE-CERT) dual 90m3 environmental chambers. Incremental aerosol yields were determined for each of the VOCs studied and compared to yields found from single precursor studies. Aerosol physical properties of density, volatility, and hygroscopicity were monitored throughout experiments. Bulk elemental chemical composition from high-resolution time of flight aerosol mass spectrometer (HR-ToF-AMS) data will also be presented. Incremental yields and SOA chemical and physical characteristics will be compared with data from previous single VOC studies conducted for these aerosol precursors following traditional VOC/NOx chamber experiments. Evaluation of the incremental effects of VOCs on SOA formation and properties are paramount in evaluating how to best extrapolate environmental chamber observations to the ambient atmosphere and provides useful insights into current SOA formation models. Further, the comparison of incremental SOA from VOCs in varying surrogate urban atmospheres (with and without strong biogenic influence) allows for a unique perspective on the impacts different compounds have on aerosol formation in different urban regions.
Development of a database for chemical mechanism assignments for volatile organic emissions.
Carter, William P L
2015-10-01
The development of a database for making model species assignments when preparing total organic gas (TOG) emissions input for atmospheric models is described. This database currently has assignments of model species for 12 different gas-phase chemical mechanisms for over 1700 chemical compounds and covers over 3000 chemical categories used in five different anthropogenic TOG profile databases or output by two different biogenic emissions models. This involved developing a unified chemical classification system, assigning compounds to mixtures, assigning model species for the mechanisms to the compounds, and making assignments for unknown, unassigned, and nonvolatile mass. The comprehensiveness of the assignments, the contributions of various types of speciation categories to current profile and total emissions data, inconsistencies with existing undocumented model species assignments, and remaining speciation issues and areas of needed work are also discussed. The use of the system to prepare input for SMOKE, the Speciation Tool, and for biogenic models is described in the supplementary materials. The database, associated programs and files, and a users manual are available online at http://www.cert.ucr.edu/~carter/emitdb . Assigning air quality model species to the hundreds of emitted chemicals is a necessary link between emissions data and modeling effects of emissions on air quality. This is not easy and makes it difficult to implement new and more chemically detailed mechanisms in models. If done incorrectly, it is similar to errors in emissions speciation or the chemical mechanism used. Nevertheless, making such assignments is often an afterthought in chemical mechanism development and emissions processing, and existing assignments are usually undocumented and have errors and inconsistencies. This work is designed to address some of these problems.
Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda
2014-10-01
This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.
Validation of Test Methods for Air Leak Rate Verification of Spaceflight Hardware
NASA Technical Reports Server (NTRS)
Oravec, Heather Ann; Daniels, Christopher C.; Mather, Janice L.
2017-01-01
As deep space exploration continues to be the goal of NASAs human spaceflight program, verification of the performance of spaceflight hardware becomes increasingly critical. Suitable test methods for verifying the leak rate of sealing systems are identified in program qualification testing requirements. One acceptable method for verifying the air leak rate of gas pressure seals is the tracer gas leak detector method. In this method, a tracer gas (commonly helium) leaks past the test seal and is transported to the leak detector where the leak rate is quantified. To predict the air leak rate, a conversion factor of helium-to-air is applied depending on the magnitude of the helium flow rate. The conversion factor is based on either the molecular mass ratio or the ratio of the dynamic viscosities. The current work was aimed at validating this approach for permeation-level leak rates using a series of tests with a silicone elastomer O-ring. An established pressure decay method with constant differential pressure was used to evaluate both the air and helium leak rates of the O-ring under similar temperature and pressure conditions. The results from the pressure decay tests showed, for the elastomer O-ring, that neither the molecular flow nor the viscous flow helium-to-air conversion factors were applicable. Leak rate tests were also performed using nitrogen and argon as the test gas. Molecular mass and viscosity based helium-to-test gas conversion factors were applied, but did not correctly predict the measured leak rates of either gas. To further this study, the effect of pressure boundary conditions was investigated. Often, pressure decay leak rate tests are performed at a differential pressure of 101.3 kPa with atmospheric pressure on the downstream side of the test seal. In space applications, the differential pressure is similar, but with vacuum as the downstream pressure. The same O-ring was tested at four unique differential pressures ranging from 34.5 to 137.9 kPa. Up to six combinations of upstream and downstream pressures for each differential pressure were compared. For a given differential pressure, the various combinations of upstream and downstream dry air pressures did not significantly affect the leak rate. As expected, the leak rate of the O-ring increased with increasing differential pressure. The results suggested that the current leak test pressure conditions, used to verify spacecraft sealing systems with elastomer seals, produce accurate values even though the boundary conditions do not model the space application.
49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...
49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...
49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...
49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...
49 CFR 219.602 - FRA Administrator's determination of random drug testing rate.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Random Alcohol and Drug Testing Programs § 219.602 FRA Administrator's determination of random drug... percentage rate for random drug testing must be 50 percent of covered employees. (b) The FRA Administrator's decision to increase or decrease the minimum annual percentage rate for random drug testing is based on the...
7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...
7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...
7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...
7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Standard hourly fee rate for laboratory testing... AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS SERVICES AND GENERAL INFORMATION Fees and Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The...
Zhang, Daogong; Fan, Zhaomin; Han, Yuechen; Wang, Mingming; Xu, Lei; Luo, Jianfen; Ai, Yu; Wang, Haibo
2012-01-01
To investigate the diagnostic value of vestibular test and high stimulus rate auditory brainstem response (ABR) test and the possible mechanism responsible for benign paroxysmal vertigo of childhood (BPVC). Data of 56 patients with BPVC in vertigo clinic of our hospital from May 2007 to September 2008 were retrospectively analyzed in this study. Patients with BPVC were tested with pure tone audiometry, high stimulus rate auditory brainstem response test (ABR), transcranial Doppler sonography (TCD), bithermal caloric test, and VEMP. The results of the hearing and vestibular function test were compared and analyzed. There were 56 patients with BPVC, including 32 men, 24 women, aged 3-12 years old, with an average of 6.5 years. Among 56 cases of BPVC patients, the results of pure tone audiometry were all normal. High stimulus rate ABR was abnormal in 66.1% (37/56) of cases. TCD showed 57.1% abnormality in 56 cases, including faster flow rate in 28 cases and slower flow rate in 4 cases. High stimulus rate ABR and TCD were both abnormal in 48.2% (27/56) of cases. Bithermal caloric test was abnormal in 14.3% (8/56) of cases. VEMP showed 32.1% abnormality, including amplitude abnormality in 16 cases and latency abnormality in 2 cases. The abnormal rate of VEMP was much higher than that of caloric test. Vascular mechanisms might be involved in the pathogenesis of BPVC and there is strong evidence for close relationship between BPVC and migraine. High stimulus rate ABR is helpful in the diagnosis of BPVC. The inferior vestibular pathway is much more impaired than the superior vestibular pathway in BPVC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, S.; Fleming, T.; Westra, C.
This report summarizes the data from the semi-annual reports on fitness-for-duty programs submitted to the NRC by 52 utilities for two reporting periods: January 1, 1991 to June 30,1991, and from July 1, 1991, to December 31, 1991. During 1991, licensees reported that they had conducted 262,597 tests for the presence of illegal drugs and alcohol. Of these tests, 1,722 (.66%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (983) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, theremore » were 510 positive tests from random testing and 167 positive tests from forcause testing. Follow-up testing of workers who had previously tested positive resulted in 62 positive tests. Forcause testing resulted in the highest percentage of positive tests; about 23 percent of forcause tests were positive. This compares to a positive test rate of .94 percent of preaccess tests and .33 percent of random tests. Positive test rates also varied by category of worker. Overall, short-term contractor personnel had the highest positive test rate at .98 percent. licensee employees and long-term contractors had lower positive test rates (33% and .56%, respectively). Of the substances tested, marijuana was responsible for the highest percentage (42.3%) of positive test results, followed by cocaine (31.2%) and alcohol (22.8%). Positive test results are also reported for NRC administrative regions, for plants experiencing or not experiencing an outage during a six-month period; and for plants located in areas with different rates of population density, crime, and drug and alcohol use. A comparison of positive test results in 1991 with those found in 1990 found a decrease in the positive test rate for each category of test and worker.« less
Fitness for duty in the nuclear power industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, S.; Fleming, T.; Westra, C.
This report summarizes the data from the semi-annual reports on fitness-for-duty programs submitted to the NRC by 52 utilities for two reporting periods: January 1, 1991 to June 30,1991, and from July 1, 1991, to December 31, 1991. During 1991, licensees reported that they had conducted 262,597 tests for the presence of illegal drugs and alcohol. Of these tests, 1,722 (.66%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (983) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, theremore » were 510 positive tests from random testing and 167 positive tests from forcause testing. Follow-up testing of workers who had previously tested positive resulted in 62 positive tests. Forcause testing resulted in the highest percentage of positive tests; about 23 percent of forcause tests were positive. This compares to a positive test rate of .94 percent of preaccess tests and .33 percent of random tests. Positive test rates also varied by category of worker. Overall, short-term contractor personnel had the highest positive test rate at .98 percent. licensee employees and long-term contractors had lower positive test rates (33% and .56%, respectively). Of the substances tested, marijuana was responsible for the highest percentage (42.3%) of positive test results, followed by cocaine (31.2%) and alcohol (22.8%). Positive test results are also reported for NRC administrative regions, for plants experiencing or not experiencing an outage during a six-month period; and for plants located in areas with different rates of population density, crime, and drug and alcohol use. A comparison of positive test results in 1991 with those found in 1990 found a decrease in the positive test rate for each category of test and worker.« less
Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L
2017-01-01
Background Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. Objectives We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Methods Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Results Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Conclusions Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. PMID:27193033
Empirical Tests of the Assumptions Underlying Models for Foreign Exchange Rates.
1984-03-01
Research Report COs 481 EMPIRICAL TESTS OF THE ASSUMPTIO:IS UNDERLYING MODELS FOR FOREIGN EXCHANGE RATES by P. Brockett B. Golany 00 00 CENTER FOR...Research Report CCS 481 EMPIRICAL TESTS OF THE ASSUMPTIONS UNDERLYING MODELS FOR FOREIGN EXCHANGE RATES by P. Brockett B. Golany March 1984...applying these tests to the U.S. dollar to Japanese Yen foreign exchange rates . Conclusions and discussion is given in section VI. 1The previous authors
Prahm, Kira P.; Witting, Nanna; Vissing, John
2014-01-01
Objective The 6-minute walk test is widely used to assess functional status in neurological disorders. However, the test is subject to great inter-test variability due to fluctuating motivation, fatigue and learning effects. We investigated whether inter-test variability of the 6MWT can be reduced by heart rate correction. Methods Sixteen patients with neuromuscular diseases, including Facioscapulohumeral muscular dystrophy, Limb-girdle muscular dystrophy, Charcot-Marie-Tooths, Dystrophia Myotonica and Congenital Myopathy and 12 healthy subjects were studied. Patients were excluded if they had cardiac arrhythmias, if they received drug treatment for hypertension or any other medical conditions that could interfere with the interpretation of the heart rate and walking capability. All completed three 6-minute walk tests on three different test-days. Heart rate was measured continuously. Results Successive standard 6-minute walk tests showed considerable learning effects between Tests 1 and 2 (4.9%; P = 0.026), and Tests 2 and 3 (4.5%; P = 0.020) in patients. The same was seen in controls between Tests 1 and 2 (8.1%; P = 0.039)). Heart rate correction abolished this learning effect. Conclusion A modified 6-minute walk test, by correcting walking distance with average heart rate during walking, decreases the variability among repeated 6-minute walk tests, and should be considered as an alternative outcome measure to the standard 6-minute walk test in future clinical follow-up and treatment trials. PMID:25479403
Errors of car wheels rotation rate measurement using roller follower on test benches
NASA Astrophysics Data System (ADS)
Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.
2018-03-01
The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.
Oh, Myung Ok; Kim, Young Jeoum; Baek, Cho Hee; Kim, Ju Hee; Park, No Mi; Yu, Mi Jeong; Song, Han Sol
2016-06-01
The purpose of this cross-over experimental study was to examine effects of music intervention on maternal anxiety, fetal heart rate pattern and testing time during non-stress tests (NST) for antenatal fetal assessment. Sixty pregnant women within 28 to 40 gestational weeks were randomly assigned to either the experimental group (n=30) or control group (n=30). Music intervention was provided to pregnant women in the experimental group during NST. Degree of maternal anxiety and fetal heart rate pattern were our primary outcomes. State-trait anxiety inventory, blood pressure, pulse rate, and changes in peripheral skin temperature were assessed to determine the degree of maternal anxiety. Baseline fetal heart rate, frequency of acceleration in fetal heart rate, fetal movement test and testing time for reactive NST were assessed to measure the fetal heart rate pattern. The experimental group showed significantly lower scores in state anxiety than the control group. There were no significant differences in systolic blood pressure and pulse rate between the two groups. Baseline fetal heart rate was significantly lower in the experimental group than in the control group. Frequency of acceleration in fetal heart rate was significantly increased in the experimental group compared to the control group. There were no significant differences in fetal movement and testing time for reactive NST between the two groups. Present results suggest that music intervention could be an effective nursing intervention for alel viating anxiety during non-stress test.
Total dose bias dependency and ELDRS effects in bipolar linear devices
NASA Technical Reports Server (NTRS)
Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.
2002-01-01
Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.
Measurement at low strain rates of the elastic properties of dental polymeric materials.
Chabrier, F; Lloyd, C H; Scrimgeour, S N
1999-01-01
To evaluate a simple static test (i.e. a slow strain rate test) designed to measure Young's modulus and the bulk modulus of polymeric materials (The NOL Test). Though it is a 'mature' test as yet it has never been applied to dental materials. A small cylindrical specimen is contained in a close-fitting steel constraining ring and compressive force applied to the ends by steel pistons. The initial (unconstrained) deformation is controlled by Young's modulus. Lateral spreading leads to constraint from the ring and subsequent deformation is controlled by the bulk modulus. A range of dental materials and reference polymers were selected and both moduli measured. From these data Poisson's ratios were calculated. The test proved be a simple reliable method for obtaining values for these properties. For composite the value of Young's modulus was lower, bulk modulus relatively similar and Poisson's ratio higher than that obtained from high strain rate techniques (as expected for a strain rate sensitive material). This test does fulfil a requirement for a simple test to define fully the elastic properties of dental polymeric materials. Measurements are made at the strain rates used in conventional static tests and values reflect this test condition. The higher values obtained for Poisson's ratio at this slow strain rate has implications for FEA, in that analysis is concerned with static or slow rate loading situations.
Prediction of failure pressure and leak rate of stress corrosion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majumdar, S.; Kasza, K.; Park, J. Y.
2002-06-24
An ''equivalent rectangular crack'' approach was employed to predict rupture pressures and leak rates through laboratory generated stress corrosion cracks and steam generator tubes removed from the McGuire Nuclear Station. Specimen flaws were sized by post-test fractography in addition to a pre-test advanced eddy current technique. The predicted and observed test data on rupture and leak rate are compared. In general, the test failure pressures and leak rates are closer to those predicted on the basis of fractography than on nondestructive evaluation (NDE). However, the predictions based on NDE results are encouraging, particularly because they have the potential to determinemore » a more detailed geometry of ligamented cracks, from which failure pressure and leak rate can be more accurately predicted. One test specimen displayed a time-dependent increase of leak rate under constant pressure.« less
Sample features associated with success rates in population-based EGFR mutation testing.
Shiau, Carolyn J; Babwah, Jesse P; da Cunha Santos, Gilda; Sykes, Jenna R; Boerner, Scott L; Geddie, William R; Leighl, Natasha B; Wei, Cuihong; Kamel-Reid, Suzanne; Hwang, David M; Tsao, Ming-Sound
2014-07-01
Epidermal growth factor receptor (EGFR) mutation testing has become critical in the treatment of patients with advanced non-small-cell lung cancer. This study involves a large cohort and epidemiologically unselected series of EGFR mutation testing for patients with nonsquamous non-small-cell lung cancer in a North American population to determine sample-related factors that influence success in clinical EGFR testing. Data from consecutive cases of Canadian province-wide testing at a centralized diagnostic laboratory for a 24-month period were reviewed. Samples were tested for exon-19 deletion and exon-21 L858R mutations using a validated polymerase chain reaction method with 1% to 5% detection sensitivity. From 2651 samples submitted, 2404 samples were tested with 2293 samples eligible for analysis (1780 histology and 513 cytology specimens). The overall test-failure rate was 5.4% with overall mutation rate of 20.6%. No significant differences in the failure rate, mutation rate, or mutation type were found between histology and cytology samples. Although tumor cellularity was significantly associated with test-success or mutation rates in histology and cytology specimens, respectively, mutations could be detected in all specimen types. Significant rates of EGFR mutation were detected in cases with thyroid transcription factor (TTF)-1-negative immunohistochemistry (6.7%) and mucinous component (9.0%). EGFR mutation testing should be attempted in any specimen, whether histologic or cytologic. Samples should not be excluded from testing based on TTF-1 status or histologic features. Pathologists should report the amount of available tumor for testing. However, suboptimal samples with a negative EGFR mutation result should be considered for repeat testing with an alternate sample.
Airline Transport Pilot and/or Type Rating - Practical Test Standards for Airplane, Helicopter
DOT National Transportation Integrated Search
1995-07-01
The Airline Transport Pilot and/or Type Rating Practical Test Standards : (PTS) book has been published by the Federal Aviation Administration : (FAA) to establish the standards for Airline Transport Pilot and Type Rating : practical tests for airpla...
Validation of Empirically Derived Rating Scales for a Story Retelling Speaking Test
ERIC Educational Resources Information Center
Hirai, Akiyo; Koizumi, Rie
2013-01-01
In recognition of the rating scale as a crucial tool of performance assessment, this study aims to establish a rating scale suitable for a Story Retelling Speaking Test (SRST), which is a semidirect test of speaking ability in English as a foreign language for classroom use. To identify an appropriate scale, three rating scales, all of which have…
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Bansal, Narottam P.; Gyekenyesi, John P.
2003-01-01
Both interlaminar and in-plane shear strengths of a unidirectional Hi-Nicalon(TM) fiber-reinforced barium strontium aluminosilicate (SiC/BSAS) composite were determined at 1100 C in air as a function of test rate using double notch shear test specimens. The composite exhibited a significant effect of test rate on shear strength, regardless of orientation which was either in interlaminar or in in-plane direction, resulting in an appreciable shear-strength degradation of about 50 percent as test rate decreased from 3.3 10(exp -1) mm/s to 3.3 10(exp -5) mm/s. The rate dependency of composite's shear strength was very similar to that of ultimate tensile strength at 1100 C observed in a similar composite (2-D SiC/BSAS) in which tensile strength decreased by about 60 percent when test rate varied from the highest (5 MPa/s) to the lowest (0.005 MPa/s). A phenomenological, power-law slow crack growth formulation was proposed and formulated to account for the rate dependency of shear strength of the composite.
Testing-adjusted chlamydia notification trends in New South Wales, Australia, 2000 to 2010.
Cretikos, Michelle; Mayne, Darren; Reynolds, Roderick; Spokes, Paula; Madeddu, Daniel
2014-01-01
Between 2005 and 2010, Australian notification rates for chlamydia infection increased by 64% from 203 to 333 per 100 000 population. Interpreting this trend is difficult without examining rates and local patterns of testing. We examined the effect of adjusting for local testing rates on chlamydia notification trends in New South Wales (NSW), Australia from 2000 to 2010. We used testing data for NSW residents for Medicare Benefits Schedule items for chlamydia from 1 July 1999 to 30 June 2005 and 1 July 2007 to 30 June 2010. This data set excluded testing by public sector laboratories. We also obtained laboratory-confirmed genital chlamydia notifications in NSW residents for 1 July 1999 to 30 June 2010 and excluded notifications from public laboratories. We used negative binomial regression to assess trends in chlamydia notification rates by age and sex after adjusting for local government area (LGA)-level Medicare-funded testing rates, socioeconomic disadvantage, remoteness and Medicare provider density. Testing-adjusted rates of chlamydia notifications declined by 5.2% per annum (rate ratio [RR] = 0.95, 95% confidence interval (CI) = 0.93-0.96) for women overall, and 2.3% (RR = 0.98, 95% CI = 0.96-1.00) and 5.0% per annum (RR = 0.95, 95% CI = 0.93-0.98) for men in LGAs with moderate and high densities of Medicare providers, respectively. Notification rates remained stable for men in low Medicare provider density LGAs (RR = 1.01, 95% CI = 0.96-1.07). It is likely that increased testing for chlamydia has driven increases in chlamydia notification in NSW over the last decade. Notification data provide no evidence for a general increase in the prevalence of chlamydia in the NSW community for this period. Notification-based chlamydia surveillance should be routinely adjusted for local testing rates.
Boettiger, David C; Law, Matthew G; Dore, Gregory J; Guy, Rebecca; Callander, Denton; Donovan, Basil; O'Connor, Catherine C; Fairley, Christopher K; Hellard, Margaret; Matthews, Gail
2017-12-01
Direct acting antivirals are expected to drastically reduce the burden of hepatitis C virus (HCV) in people living with Human Immunodeficiency Virus (HIV). However, rates of HCV testing, re-testing and incident infection in this group remain uncertain in Australia. We assessed trends in HCV testing, re-testing and incident infection among HIV-positive individuals, and evaluated factors associated with HCV re-testing and incident infection. The study population consisted of HIV-positive individuals who visited a sexual health service involved in the Australian Collaboration for Coordinated Enhanced Sentinel Surveillance (ACCESS) between 2007 and 2015. Poisson regression was used to assess trends and to evaluate factors associated with HCV re-testing and incident HCV infection. There were 9227 HIV-positive individuals included in our testing rate analysis. Of 3799 HIV-positive/HCV-negative people that attended an ACCESS sexual health service more than once, 2079 (54.7%) were re-tested for HCV and were therefore eligible for our incidence analysis. The rate of HCV testing increased from 17.1 to 51.4 tests per 100 patient years between 2007 and 2015 (p for trend <0.01). Over the same period, HCV re-testing rates increased from 23.9 to 79.7 tests per 100 person years (p for trend <0.01). A clear increase in testing and re-testing began after 2011. Patients who identified as men who have sex with men and those with a history of injecting drug use experienced high rates of HCV re-testing over the course of the study period. Among those who re-tested, 157 incident HCV infections occurred at a rate of 2.5 events per 100 person years. Between 2007 and 2009, 2010-2011, 2012-2013 and 2014-2015, rates of incident HCV were 0.8, 1.5, 3.9 and 2.7 events per 100 person years, respectively (p for trend <0.01). Incident HCV was strongly associated with a history of injecting drug use. High rates of HCV testing and re-testing among HIV-positive individuals in Australia will assist strategies to achieve HCV elimination through rapid treatment scale up. Continued monitoring of HCV incidence in this population is essential for guiding both HCV prevention and treatment strategies.
Effects of health information exchange adoption on ambulatory testing rates
Ross, Stephen E; Radcliff, Tiffany A; LeBlanc, William G; Dickinson, L Miriam; Libby, Anne M; Nease, Donald E
2013-01-01
Objective To determine the effects of the adoption of ambulatory electronic health information exchange (HIE) on rates of laboratory and radiology testing and allowable charges. Design Claims data from the dominant health plan in Mesa County, Colorado, from 1 April 2005 to 31 December 2010 were matched to HIE adoption data on the provider level. Using mixed effects regression models with the quarter as the unit of analysis, the effect of HIE adoption on testing rates and associated charges was assessed. Results Claims submitted by 306 providers in 69 practices for 34 818 patients were analyzed. The rate of testing per provider was expressed as tests per 1000 patients per quarter. For primary care providers, the rate of laboratory testing increased over the time span (baseline 1041 tests/1000 patients/quarter, increasing by 13.9 each quarter) and shifted downward with HIE adoption (downward shift of 83, p<0.01). A similar effect was found for specialist providers (baseline 718 tests/1000 patients/quarter, increasing by 19.1 each quarter, with HIE adoption associated with a downward shift of 119, p<0.01). Even so, imputed charges for laboratory tests did not shift downward significantly in either provider group, possibly due to the skewed nature of these data. For radiology testing, HIE adoption was not associated with significant changes in rates or imputed charges in either provider group. Conclusions Ambulatory HIE adoption is unlikely to produce significant direct savings through reductions in rates of testing. The economic benefits of HIE may reside instead in other downstream outcomes of better informed, higher quality care. PMID:23698257
DOT National Transportation Integrated Search
2013-08-01
The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...
DOT National Transportation Integrated Search
2013-08-01
The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...
DOT National Transportation Integrated Search
2013-08-01
The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westra, C.; Durbin, N.; Field, I.
This report summarizes the data from the semiannual reports on fitness-for-duty programs submitted to the NRC by utilities for two reporting periods: January 1 through June 30, 1994, and July I through December 31, 1994. During 1994, licensees reported that they had conducted 163,241 tests for the presence of illegal drugs and alcohol. Of these tests, 1,372 (.84%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (977) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 223 positivemore » tests from random testing and 122 positive tests from for-cause testing. Follow-up testing of workers who had previously tested positive resulted in 50 positive tests. For-cause testing resulted in the highest percentage of positive tests; about 16 percent of for-cause tests were positive. This compares with a positive test rate of 1.22 percent of pre-access tests and .28 percent of random tests. The positive test rate for badged workers (including only random, for-cause, and follow-up test results) was .48 percent. Positive test rates also varied by category of worker. When all types of tests are combined (pre-access, random, for-cause, and follow-up testing), short-term contractor personnel had the highest positive test rate at 1.22 percent. Licensee employees and long-term contractors had lower combined positive test rates (.33% and .49%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (52.07%), followed by cocaine (24.25%) and alcohol (17.45%).« less
Melter Throughput Enhancements for High-Iron HLW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, A. A.; Gan, Hoa; Joseph, Innocent
2012-12-26
This report describes work performed to develop and test new glass and feed formulations in order to increase glass melting rates in high waste loading glass formulations for HLW with high concentrations of iron. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to assess melt rate using a vertical gradient furnace system and to develop new formulations with enhanced melt rate. Testing evaluated the effects of waste loading on glass properties and themore » maximum waste loading that can be achieved. The results from crucible-scale testing supported subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass and feed formulations on waste processing rate and product quality. The DM100 was selected as the platform for these tests due to its extensive previous use in processing rate determination for various HLW streams and glass compositions.« less
Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.
2015-01-01
An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.
Rudolf, Joseph; Jackson, Brian R; Wilson, Andrew R; Smock, Kristi J; Schmidt, Robert L
2017-04-01
Health care organizations are under increasing pressure to deliver value by improving test utilization management. Many factors, including organizational factors, could affect utilization performance. Past research has focused on the impact of specific interventions in single organizations. The impact of organizational factors is unknown. The objective of this study is to determine whether testing patterns are subject to organizational effects, ie, are utilization patterns for individual tests correlated within organizations. Comparative analysis of ordering patterns (positivity rates for three genetic tests) across 659 organizations. Hierarchical regression was used to assess the impact of organizational factors after controlling for test-level factors (mutation prevalence) and hospital bed size. Test positivity rates were correlated within organizations. Organizations have a statistically significant impact on the positivity rate of three genetic tests. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Price, James W
Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.
Differences in state drug testing and reporting by driver type in U.S. fatal traffic crashes.
Slater, Megan E; Castle, I-Jen P; Logan, Barry K; Hingson, Ralph W
2016-07-01
Driving under the influence of drugs, including marijuana, has become more prevalent in recent years despite local, state, and federal efforts to prevent such increases. The Fatality Analysis Reporting System (FARS) is the primary source of drugged driving data for fatal crashes in the United States but lacks the completeness required to calculate unbiased estimates of drug use among drivers involved in fatal crashes. This article uses the 2013 FARS dataset to present differences in state drug testing rates by driver type, driver fault type, and state-level factors; discusses limitations related to analysis and interpretation of drugged driving data; and offers suggestions for improvements that may enable appropriate use of FARS drug testing data in the future. Results showed that state drug testing rates were highest among drivers who died at the scene of the crash (median=70.8%) and drivers who died and were at fault in the crash (median=64.4%). The lowest testing rates were seen among surviving drivers who were not transported to a hospital (median=14.0%) and surviving drivers who were not at fault in the crash (median=10.0%). Drug testing rates differed by state blood alcohol content (BAC) testing rate across all driver types and driver fault types, and in general, states that tested a higher percentage of drivers for BAC had higher drug testing rates. Testing rates might be increased through standardization and mandatory testing policies. FARS data users should continue to be cautious about the limitations of using currently available data to quantify drugged driving. More efforts are needed to improve drug testing and reporting practices, and more research is warranted to establish drug concentration levels at which driving skills become impaired. Copyright © 2016 Elsevier Ltd. All rights reserved.
77 FR 21038 - Energy Conservation Program: Test Procedures for Light-Emitting Diode Lamps
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-09
... Photometric Measurements of Solid-State Lighting Products'' for determining lumen output, input power, and CCT.... Test Method 5. Test Calculations and Rounding C. Proposed Approach for Rated Lifetime Measurements 1... Test Method to Project Rated Lifetime 4. Test Conditions 5. Test Setup 6. Test Method and Measurements...
ERIC Educational Resources Information Center
Frederick, Richard I.; Bowden, Stephen C.
2009-01-01
Common rates employed in classificatory testing are the true positive rate (TPR), false positive rate (FPR), positive predictive power (PPP), and negative predictive power (NPP). FPR and TPR are estimated from research samples representing populations to be distinguished by classificatory testing. PPP and NPP are used by clinicians to classify…
An Assessment of Drug Testing within the Construction Industry.
ERIC Educational Resources Information Center
Gerber, Jonathan K.; Yacoubian, George S., Jr.
2002-01-01
Investigates the efficacy of workplace drug-testing programs in reducing injury incident rates and workers' compensation experience-rating modification factors within the construction industry. Analyses indicate that companies with drug-testing programs experienced a 51 percent reduction in incident rates within two years of implementation.…
40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...
40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...
40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...
40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...
NASA Technical Reports Server (NTRS)
Paglietti, A.
1982-01-01
At high strain rates the heat produced by plastic deformation can give rise to a rate dependent response even if the material has rate independent constitutive equations. This effect has to be evaluated when interpreting a material test, or else it could erroneously be ascribed to viscosity. A general thermodynamic theory of tensile testing of elastic-plastic materials is given in this paper; it is valid for large strain at finite strain rates. It enables discovery of the parameters governing the thermodynamic strain rate effect, provides a method for proper interpretation of the results of the tests of dynamic plasticity, and suggests a way of planning experiments in order to detect the real contribution of viscosity.
Desai, Sunita
2016-01-01
Objective To examine the effect on BRCA testing and mastectomy rates of a widely viewed 2013 New York Times editorial by public figure Angelina Jolie that endorsed BRCA testing and announced Jolie’s decision to undergo preventive mastectomy. Design Observational study with difference-in-difference analysis. Setting Commercially insured US population. Participants Women aged 18-64 years with claims in the Truven MarketScan commercial claims database (n=9 532 836). Main outcome measures Changes in BRCA testing rates in the 15 business days before versus after 14 May 2013 (editorial date) compared with the change in the same period in 2012; mastectomy rates in the months before and after publication, both overall and within 60 days of BRCA testing among women who were tested; national estimates of incremental tests and expenditures associated with Jolie’s article in the 15 days after publication. Results Daily BRCA test rates increased immediately after the 2013 editorial, from 0.71 tests/100 000 women in the 15 business days before to 1.13 tests/100 000 women in the 15 business days after publication. In comparison, daily test rates were similar in the same period in 2012 (0.58/100 000 women in the 15 business days before 14 May versus 0.55/100 000 women in the 15 business days after), implying a difference-in-difference absolute daily increase of 0.45 tests/100 000 women or a 64% relative increase (P<0.001). The editorial was associated with an estimated increase of 4500 BRCA tests and $13.5m (£10.8m; €12.8) expenditure nationally among commercially insured adult women in those 15 days. Increased BRCA testing rates were sustained throughout 2013. Overall mastectomy rates remained unchanged in the months after publication, but 60 day mastectomy rates among women who had a BRCA test fell from 10% in the months before publication to 7% in the months after publication, suggesting that women who underwent tests as a result of to the editorial had a lower pre-test probability of having the BRCA mutation than women tested before the editorial. Conclusions Celebrity endorsements can have a large and immediate effect on use of health services. Such announcements can be a low cost means of reaching a broad audience quickly, but they may not effectively target the subpopulations that are most at risk for the relevant underlying condition. PMID:27974323
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fleming, T.; Westra, C.; Field, I.
This report summarizes the data from the semi-annual reports on fitness-for-duty programs submitted to the NRC by 52 utilities for two reporting periods: January 1 through June 30, 1992, and July 1 through December 31, 1992. During 1992, licensees reported that they had conducted 266,551 tests for the presence of illegal drugs and alcohol. Of these test, 1,818 (.68%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (1,110) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 461more » positive tests from random testing and 178 positive tests from for-cause testing. Follow-up testing of workers who had previously tested positive resulted in 69 positive tests. For-cause testing resulted in the highest percentage of positive-tests; about 26% of for-cause tests were positive. This compares to a positive test rate of 1.06 percent of pre-access tests and .29 percent of random tests. Positive test rates also varied by category of worker. Overall, short-term contractor personnel had the highest positive test rate at 1.00 percent. Licensee employees and long-term contractors had lower positive test rates (.29% and .63%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (50.3%), followed by cocaine (24.8%) and alcohol (22.6%). Positive test results are also reported for NRC administrative regions and for plants located in areas with different rates of population density.« less
A Robust Semi-Parametric Test for Detecting Trait-Dependent Diversification.
Rabosky, Daniel L; Huang, Huateng
2016-03-01
Rates of species diversification vary widely across the tree of life and there is considerable interest in identifying organismal traits that correlate with rates of speciation and extinction. However, it has been challenging to develop methodological frameworks for testing hypotheses about trait-dependent diversification that are robust to phylogenetic pseudoreplication and to directionally biased rates of character change. We describe a semi-parametric test for trait-dependent diversification that explicitly requires replicated associations between character states and diversification rates to detect effects. To use the method, diversification rates are reconstructed across a phylogenetic tree with no consideration of character states. A test statistic is then computed to measure the association between species-level traits and the corresponding diversification rate estimates at the tips of the tree. The empirical value of the test statistic is compared to a null distribution that is generated by structured permutations of evolutionary rates across the phylogeny. The test is applicable to binary discrete characters as well as continuous-valued traits and can accommodate extremely sparse sampling of character states at the tips of the tree. We apply the test to several empirical data sets and demonstrate that the method has acceptable Type I error rates. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Investigating Barriers in HIV-Testing Oncology Patients: The IBITOP Study, Phase I.
Merz, Laurent; Zimmermann, Stefan; Peters, Solange; Cavassini, Matthias; Darling, Katharine E A
2016-10-01
Although the prevalence of non-AIDS-defining cancers (non-ADCs) among people living with HIV is rising, we observed HIV testing rates below 5% at our oncology center, against a regional HIV prevalence of 0.2%-0.4%. We performed the Investigating Barriers in HIV-Testing Oncology Patients (IBITOP) study among oncology physicians and patients. Between July 1 and October 31, 2013, patients of unknown HIV status newly diagnosed with solid-organ non-ADCs referred to Lausanne University Hospital Oncology Service, Switzerland, were offered free HIV testing as part of their oncology work-up. The primary endpoints were (a) physician willingness to offer and patient acceptance of HIV testing and (b) physicians' reasons for not offering testing. Of 239 patients of unknown HIV status with a new non-ADC diagnosis, 43 (18%) were offered HIV testing, of whom 4 declined (acceptance rate: 39 of 43; 91%). Except for 21 patients tested prior to oncology consultation, 175 patients (of 239; 73%) were not offered testing. Testing rate declined among patients who were >70 years old (12% versus 30%; p = .04); no non-European patients were tested. Physicians gave reasons for not testing in 16% of cases, the main reason being patient follow-up elsewhere (10 patients; 5.7%). HIV testing during the IBITOP study increased the HIV testing rate to 18%. Although the IBITOP study increased HIV testing rates, most patients were not tested. Testing was low or nonexistent among individuals at risk of late HIV presentation (older patients and migrants). Barriers to testing appear to be physician-led, because patient acceptance of testing offered was very high (91%). In November 2013, the Swiss HIV testing recommendations were updated to propose testing in cancer patients. Phase II of the IBITOP study is examining the effect of these recommendations on HIV testing rates and focusing on physician-led testing barriers. Patients of unknown HIV status newly diagnosed with solid-organ non-AIDS-defining cancers were offered free HIV testing. Physician and patient barriers to HIV testing were examined. Most patients (82%) were not offered testing, and testing of individuals at risk of late HIV presentation (older patients and migrants) was low or nonexistent. Conversely, patient acceptance of testing offered was very high (91%), suggesting that testing barriers in this setting are physician-led. Since this study, the Swiss HIV testing recommendations now advise testing cancer patients before chemotherapy. Phase II of the Investigating Barriers in HIV-Testing Oncology Patients study is examining the effect of these recommendations on testing rates and physician barriers. ©AlphaMed Press.
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2010 CFR
2010-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2014 CFR
2014-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2011 CFR
2011-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2012 CFR
2012-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
40 CFR 51.352 - Basic I/M performance standard.
Code of Federal Regulations, 2013 CFR
2013-07-01
...% emission test failure rate among pre-1981 model year vehicles. (10) Waiver rate. A 0% waiver rate. (11... 20% emission test failure rate among pre-1981 model year vehicles. (11) Waiver rate. A 0% waiver rate... Requirements § 51.352 Basic I/M performance standard. (a) Basic I/M programs shall be designed and implemented...
Naugler, Christopher T; Guo, Maggie
2016-04-01
There is a need to develop and validate new metrics to access the appropriateness of laboratory test requests. The mean abnormal result rate (MARR) is a proposed measure of ordering selectivity, the premise being that higher mean abnormal rates represent more selective test ordering. As a validation of this metric, we compared the abnormal rate of lab tests with the number of tests ordered on the same requisition. We hypothesized that requisitions with larger numbers of requested tests represent less selective test ordering and therefore would have a lower overall abnormal rate. We examined 3,864,083 tests ordered on 451,895 requisitions and found that the MARR decreased from about 25% if one test was ordered to about 7% if nine or more tests were ordered, consistent with less selectivity when more tests were ordered. We then examined the MARR for community-based testing for 1,340 family physicians and found both a wide variation in MARR as well as an inverse relationship between the total tests ordered per year per physician and the physician-specific MARR. The proposed metric represents a new utilization metric for benchmarking relative selectivity of test orders among physicians. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Accelerated Testing Methodology for the Determination of Slow Crack Growth of Advanced Ceramics
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Salem, Jonathan A.; Gyekenyesi, John P.
1997-01-01
Constant stress-rate (dynamic fatigue) testing has been used for several decades to characterize slow crack growth behavior of glass and ceramics at both ambient and elevated temperatures. The advantage of constant stress-rate testing over other methods lies in its simplicity: Strengths are measured in a routine manner at four or more stress rates by applying a constant crosshead speed or constant loading rate. The slow crack growth parameters (n and A) required for design can be estimated from a relationship between strength and stress rate. With the proper use of preloading in constant stress-rate testing, an appreciable saving of test time can be achieved. If a preload corresponding to 50 % of the strength is applied to the specimen prior to testing, 50 % of the test time can be saved as long as the strength remains unchanged regardless of the applied preload. In fact, it has been a common, empirical practice in strength testing of ceramics or optical fibers to apply some preloading (less then 40%). The purpose of this work is to study the effect of preloading on the strength to lay a theoretical foundation on such an empirical practice. For this purpose, analytical and numerical solutions of strength as a function of preloading were developed. To verify the solution, constant stress-rate testing using glass and alumina at room temperature and alumina silicon nitride, and silicon carbide at elevated temperatures was conducted in a range of preloadings from O to 90 %.
Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L
2017-05-01
Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Conroy, M.J.; Nichols, J.D.
1984-01-01
Several important questions in evolutionary biology and paleobiology involve sources of variation in extinction rates. In all cases of which we are aware, extinction rates have been estimated from data in which the probability that an observation (e.g., a fossil taxon) will occur is related both to extinction rates and to what we term encounter probabilities. Any statistical method for analyzing fossil data should at a minimum permit separate inferences on these two components. We develop a method for estimating taxonomic extinction rates from stratigraphic range data and for testing hypotheses about variability in these rates. We use this method to estimate extinction rates and to test the hypothesis of constant extinction rates for several sets of stratigraphic range data. The results of our tests support the hypothesis that extinction rates varied over the geologic time periods examined. We also present a test that can be used to identify periods of high or low extinction probabilities and provide an example using Phanerozoic invertebrate data. Extinction rates should be analyzed using stochastic models, in which it is recognized that stratigraphic samples are random varlates and that sampling is imperfect
High-rate lithium thionyl chloride cells
NASA Technical Reports Server (NTRS)
Goebel, F.
1982-01-01
A high-rate C cell with disc electrodes was developed to demonstrate current rates which are comparable to other primary systems. The tests performed established the limits of abuse beyond which the cell becomes hazardous. Tests include: impact, shock, and vibration tests; temperature cycling; and salt water immersion of fresh cells.
46 CFR 107.260 - Rated load test for cranes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...
46 CFR 107.260 - Rated load test for cranes.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...
46 CFR 107.260 - Rated load test for cranes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...
46 CFR 107.260 - Rated load test for cranes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...
46 CFR 107.260 - Rated load test for cranes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Rated load test for cranes. 107.260 Section 107.260 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet...
40 CFR 63.1384 - Performance test requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during any performance test...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrison, Bridger
J-U-B ENGINEERS, Inc. (J-U-B) performed seepage tests on the CFA Wastewater Lagoons 1, 2, and 3 between August 26th and September 22nd, 2014. The lagoons were tested to satisfy the Idaho Department of Environmental Quality (DEQ) Rules (IDAPA 58.01.16) that require all lagoons be tested at a frequency of every 10 years and the Compliance Activity CA-141-03 in the DEQ Wastewater Reuse Permit for the CFA Sewage Treatment Plant (LA-000141-03). The lagoons were tested to determine if the average seepage rates are less than 0.25 in/day, the maximum seepage rate allowed for lagoons built prior to April 15, 2007. Themore » average seepage rates were estimated for each lagoon and are given in Table-ES1. The average seepage rates for Lagoons 1 and 2 are less than the allowable seepage rate of 0.25 in/day. Lagoon 1 and 2 passed the seepage test and will not have to be tested again until the year 20241. However, the average seepage rate for Lagoon 3 appears to exceed the allowable seepage rate of 0.25 in/day which means the potential source for the excessive leakage should be investigated further.« less
Agréus, Lars; Talley, Nicholas J; Jones, Michael
2016-06-01
In populations with a low prevalence rate of Helicobacter pylori (H. pylori) infection from Western countries, guidelines for the management of uninvestigated dyspepsia generally recommend that the "test and treat" strategy should be avoided in favor of empiric proton-pump inhibitor therapy in younger patients (on average < 50 years of age) without alarm symptoms and signs. The prevalence of H. pylori infection has fallen from about 30% to about 10% in Sweden and other countries. We aimed to explore whether the rationale for test and treat is relevant in contemporary clinical practice. In settings with an infection rate in the adult population of 30% and 10%, we modeled the positive and negative predictive values for indirect (nonendoscopy) tests on current H. pylori infection with a presumed sensitivity and specificity of 95%. We then calculated the difference in false-negative and false-positive test outcome, and eradication prescription rates in the two scenarios. While the positive predictive value for the test decreased from 0.89 to 0.68 when the prevalence of H. pylori fell from 30% to 10%, there were only 1% more false-negative tests and 1% less false-positive tests. The eradication prescription rate would decrease by 18% with a 10% prevalence rate. The recommendation to stop applying "test and treat" at lower prevalence rates of H. pylori should be reconsidered. The test and treat strategy is the preferred approach for most patients who present with dyspepsia. © 2015 John Wiley & Sons Ltd.
Impact of introducing near patient testing for standard investigations in general practice.
Rink, E; Hilton, S; Szczepura, A; Fletcher, J; Sibbald, B; Davies, C; Freeling, P; Stilwell, J
1993-01-01
OBJECTIVE--To assess the clinical and economic impact of surgery based near patient testing in general practice for six commonly used biochemical and bacteriological tests. DESIGN--After four months' monitoring, equipment for two bacteriological and four biochemical tests was introduced without cost into 12 practices using a crossover design. Structured request forms were used to monitor laboratory investigations. SETTING--12 general practices in west midlands and south west Thames with list sizes above 9000. MAIN OUTCOME MEASURES--Investigation rates per 1000 consultations. Changes from baseline rates. Reasons for requesting investigations and provisional diagnoses. Cost per test and sensitivity of costs to rate of use. RESULTS--Investigation rates for the six tests rose by 16.5% (from 78.6/1000 consultations to 91.6/1000) when equipment was available in the surgery and reverted to baseline rates when it was withdrawn. The average weekly number of tests when equipment was available ranged from 0.5 to 10.5 (mean 9.0). Cholesterol tests were used as an addition to laboratory testing, usually for screening. Midstream urine analysis was often done in the surgery instead of in the laboratory, although 30% of samples were tested by both methods. Doctors' reasons for investigation and conditions tested were largely unaffected by availability of surgery tests. Costs for surgery tests were higher for all tests except midstream urine. CONCLUSIONS--Availability of surgery based testing increased the number of tests performed. It was cost effective only for midstream urine analysis. PMID:8219952
Facility-level association of preoperative stress testing and postoperative adverse cardiac events.
Valle, Javier A; Graham, Laura; Thiruvoipati, Thejasvi; Grunwald, Gary; Armstrong, Ehrin J; Maddox, Thomas M; Hawn, Mary T; Bradley, Steven M
2018-06-22
Despite limited indications, preoperative stress testing is often used prior to non-cardiac surgery. Patient-level analyses of stress testing and outcomes are limited by case mix and selection bias. Therefore, we sought to describe facility-level rates of preoperative stress testing for non-cardiac surgery, and to determine the association between facility-level preoperative stress testing and postoperative major adverse cardiac events (MACE). We identified patients undergoing non-cardiac surgery within 2 years of percutaneous coronary intervention in the Veterans Affairs (VA) Health Care System, from 2004 to 2011, facility-level rates of preoperative stress testing and postoperative MACE (death, myocardial infarction (MI) or revascularisation within 30 days). We determined risk-standardised facility-level rates of stress testing and postoperative MACE, and the relationship between facility-level preoperative stress testing and postoperative MACE. Among 29 937 patients undergoing non-cardiac surgery at 131 VA facilities, the median facility rate of preoperative stress testing was 13.2% (IQR 9.7%-15.9%; range 6.0%-21.5%), and 30-day postoperative MACE was 4.0% (IQR 2.4%-5.4%). After risk standardisation, the median facility-level rate of stress testing was 12.7% (IQR 8.4%-17.4%) and postoperative MACE was 3.8% (IQR 2.3%-5.6%). There was no correlation between risk-standardised stress testing and composite MACE at the facility level (r=0.022, p=0.81), or with individual outcomes of death, MI or revascularisation. In a national cohort of veterans undergoing non-cardiac surgery, we observed substantial variation in facility-level rates of preoperative stress testing. Facilities with higher rates of preoperative stress testing were not associated with better postoperative outcomes. These findings suggest an opportunity to reduce variation in preoperative stress testing without sacrificing patient outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
A boundary-optimized rejection region test for the two-sample binomial problem.
Gabriel, Erin E; Nason, Martha; Fay, Michael P; Follmann, Dean A
2018-03-30
Testing the equality of 2 proportions for a control group versus a treatment group is a well-researched statistical problem. In some settings, there may be strong historical data that allow one to reliably expect that the control proportion is one, or nearly so. While one-sample tests or comparisons to historical controls could be used, neither can rigorously control the type I error rate in the event the true control rate changes. In this work, we propose an unconditional exact test that exploits the historical information while controlling the type I error rate. We sequentially construct a rejection region by first maximizing the rejection region in the space where all controls have an event, subject to the constraint that our type I error rate does not exceed α for any true event rate; then with any remaining α we maximize the additional rejection region in the space where one control avoids the event, and so on. When the true control event rate is one, our test is the most powerful nonrandomized test for all points in the alternative space. When the true control event rate is nearly one, we demonstrate that our test has equal or higher mean power, averaging over the alternative space, than a variety of well-known tests. For the comparison of 4 controls and 4 treated subjects, our proposed test has higher power than all comparator tests. We demonstrate the properties of our proposed test by simulation and use our method to design a malaria vaccine trial. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
NASA Astrophysics Data System (ADS)
Strader, Anne; Schorlemmer, Danijel; Beutin, Thomas
2017-04-01
The Global Earthquake Activity Rate Model (GEAR1) is a hybrid seismicity model, constructed from a loglinear combination of smoothed seismicity from the Global Centroid Moment Tensor (CMT) earthquake catalog and geodetic strain rates (Global Strain Rate Map, version 2.1). For the 2005-2012 retrospective evaluation period, GEAR1 outperformed both parent strain rate and smoothed seismicity forecasts. Since 1. October 2015, GEAR1 has been prospectively evaluated by the Collaboratory for the Study of Earthquake Predictability (CSEP) testing center. Here, we present initial one-year test results of the GEAR1, GSRM and GSRM2.1, as well as localized evaluation of GEAR1 performance. The models were evaluated on the consistency in number (N-test), spatial (S-test) and magnitude (M-test) distribution of forecasted and observed earthquakes, as well as overall data consistency (CL-, L-tests). Performance at target earthquake locations was compared between models using the classical paired T-test and its non-parametric equivalent, the W-test, to determine if one model could be rejected in favor of another at the 0.05 significance level. For the evaluation period from 1. October 2015 to 1. October 2016, the GEAR1, GSRM and GSRM2.1 forecasts pass all CSEP likelihood tests. Comparative test results show statistically significant improvement of GEAR1 performance over both strain rate-based forecasts, both of which can be rejected in favor of GEAR1. Using point process residual analysis, we investigate the spatial distribution of differences in GEAR1, GSRM and GSRM2 model performance, to identify regions where the GEAR1 model should be adjusted, that could not be inferred from CSEP test results. Furthermore, we investigate whether the optimal combination of smoothed seismicity and strain rates remains stable over space and time.
An Efficient Implementation of Fixed Failure-Rate Ratio Test for GNSS Ambiguity Resolution.
Hou, Yanqing; Verhagen, Sandra; Wu, Jie
2016-06-23
Ambiguity Resolution (AR) plays a vital role in precise GNSS positioning. Correctly-fixed integer ambiguities can significantly improve the positioning solution, while incorrectly-fixed integer ambiguities can bring large positioning errors and, therefore, should be avoided. The ratio test is an extensively used test to validate the fixed integer ambiguities. To choose proper critical values of the ratio test, the Fixed Failure-rate Ratio Test (FFRT) has been proposed, which generates critical values according to user-defined tolerable failure rates. This contribution provides easy-to-implement fitting functions to calculate the critical values. With a massive Monte Carlo simulation, the functions for many different tolerable failure rates are provided, which enriches the choices of critical values for users. Moreover, the fitting functions for the fix rate are also provided, which for the first time allows users to evaluate the conditional success rate, i.e., the success rate once the integer candidates are accepted by FFRT. The superiority of FFRT over the traditional ratio test regarding controlling the failure rate and preventing unnecessary false alarms is shown by a simulation and a real data experiment. In the real data experiment with a baseline of 182.7 km, FFRT achieved much higher fix rates (up to 30% higher) and the same level of positioning accuracy from fixed solutions as compared to the traditional critical value.
Dose Rate Effects in Linear Bipolar Transistors
NASA Technical Reports Server (NTRS)
Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis
2011-01-01
Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.
2016-07-01
bias and scale factor tests. By testing state-of-the-art gyroscopes, the effect of input rate stability and accuracy may be examined. Based on the...tumble test or bias analysis at a tilted position to remove the effect of Earth’s rotation in the scale factor test • A rate table with better rate...format guide and test procedure for coriolis vibratory gyros. Piscataway (NJ): IEEE; 2004 Dec. 3. Maio A, Smith G, Knight R, Nothwang W, Conroy J
76 FR 80781 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2012
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
...-11213, Notice No. 15] RIN 2130-AA81 Alcohol and Drug Testing: Determination of Minimum Random Testing.... According to data from FRA's Management Information System, the rail industry's random drug testing [[Page... Administrator (Administrator) has therefore determined that the minimum annual random drug testing rate for the...
Roifman, Idan; Wijeysundera, Harindra C; Austin, Peter C; Maclagan, Laura C; Rezai, Mohammad R; Wright, Graham A; Tu, Jack V
2017-02-01
The proliferation of cardiac diagnostic tests over the past few decades has received substantial attention from policymakers. However, contemporary population-based temporal trends of the utilization of noninvasive cardiac diagnostic tests for coronary artery disease are not known. Our objective was to examine the temporal trends in the utilization of coronary computed tomography angiography (CCTA), myocardial perfusion imaging (MPI), exercise stress testing (GXT), and stress echocardiography between 2008 and 2014. We performed a population-based repeated cross-sectional study of the adult population of Ontario between January 1, 2008 and December 31, 2014. Annual utilization rates of noninvasive cardiac diagnostic tests were computed. For each cardiac testing modality, a negative binomial regression model was used to assess temporal changes in test utilization. GXT and MPI collectively accounted for 88% of all cardiac noninvasive diagnostic tests throughout our study period. Age- and sex-standardized rates of GXT declined from 26.7/1000 adult population to 21.6/1000 adult population (mean annual reduction of 3.4%; P < 0.001). MPI rates declined from 21.1/1000 adult population to 19.5/1000 adult population (mean annual reduction of 1.3%; P < 0.001). Although utilization rates for both CCTA and stress echocardiography increased over time, the combined rate of all available tests decreased from 50.8/1000 adult population to 49.1/1000 adult population (mean annual reduction of 1.1%; P < 0.001). In conclusion, utilization rates for the most prevalent noninvasive cardiac diagnostic tests-GXT and MPI-declined over our study period. Furthermore, the overall test utilization rate also declined over time. We believe our findings are encouraging from a health policy perspective. Nonetheless, rising utilization rates for CCTA and stress echocardiography will need to be monitored in the future. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Hardware test program for evaluation of baseline range/range rate sensor concept
NASA Technical Reports Server (NTRS)
Pernic, E.
1985-01-01
The test program Phase II effort provides additional design information in terms of range and range rate (R/R) sensor performance when observing and tracking a typical spacecraft target. The target used in the test program was a one-third scale model of the Hubble Space Telescope (HST) available at the MSFC test site where the tests were performed. A modified Bendix millimeter wave radar served as the R/R sensor test bed for evaluation of range and range rate tracking performance, and generation of radar signature characteristics of the spacecraft target. A summary of program test results and conclusions are presented along with detailed description of the Bendix test bed radar with accompaning instrumentation. The MSFC test site and facilities are described. The test procedures used to establish background levels, and the calibration procedures used in the range accuracy tests and RCS (radar cross section) signature measurements, are presented and a condensed version of the daily log kept during the 5 September through 17 September test period is also presented. The test program results are given starting with the RCS signature measurements, then continuing with range measurement accuracy test results and finally the range and range rate tracking accuracy test results.
A New High-Speed, High-Cycle, Gear-Tooth Bending Fatigue Test Capability
NASA Technical Reports Server (NTRS)
Stringer, David B.; Dykas, Brian D.; LaBerge, Kelsen E.; Zakrajsek, Andrew J.; Handschuh, Robert F.
2011-01-01
A new high-speed test capability for determining the high cycle bending-fatigue characteristics of gear teeth has been developed. Experiments were performed in the test facility using a standard spur gear test specimens designed for use in NASA Glenn s drive system test facilities. These tests varied in load condition and cycle-rate. The cycle-rate varied from 50 to 1000 Hz. The loads varied from high-stress, low-cycle loads to near infinite life conditions. Over 100 tests were conducted using AISI 9310 steel spur gear specimen. These results were then compared to previous data in the literature for correlation. Additionally, a cycle-rate sensitivity analysis was conducted by grouping the results according to cycle-rate and comparing the data sets. Methods used to study and verify load-path and facility dynamics are also discussed.
Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors.
Atay, Aysenur; Demir, Leyla; Cuhadar, Serap; Saglam, Gulcan; Unal, Hulya; Aksun, Saliha; Arslan, Banu; Ozkan, Asuman; Sutcu, Recep
2014-01-01
Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.
7 CFR 1714.7 - Interest rate cap.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 11 2010-01-01 2010-01-01 false Interest rate cap. 1714.7 Section 1714.7 Agriculture... PRE-LOAN POLICIES AND PROCEDURES FOR INSURED ELECTRIC LOANS General § 1714.7 Interest rate cap. Except... section, or both the rate disparity test for the interest rate cap and the consumer income test set forth...
Silicon Carbide Diodes Performance Characterization and Comparison With Silicon Devices
NASA Technical Reports Server (NTRS)
Lebron-Velilla, Ramon C.; Schwarze, Gene E.; Trapp, Scott
2003-01-01
Commercially available silicon carbide (SiC) Schottky diodes from different manufacturers were electrically tested and characterized at room temperature. Performed electrical tests include steady state forward and reverse I-V curves, as well as switching transient tests performed with the diodes operating in a hard switch dc-to-dc buck converter. The same tests were performed in current state of the art silicon (Si) and gallium arsenide (GaAs) Schottky and pn junction devices for evaluation and comparison purposes. The SiC devices tested have a voltage rating of 200, 300, and 600 V. The comparison parameters are forward voltage drop at rated current, reverse current at rated voltage and peak reverse recovery currents in the dc to dc converter. Test results show that steady state characteristics of the tested SiC devices are not superior to the best available Si Schottky and ultra fast pn junction devices. Transient tests reveal that the tested SiC Schottky devices exhibit superior transient behavior. This is more evident at the 300 and 600 V rating where SiC Schottky devices showed drastically lower reverse recovery currents than Si ultra fast pn diodes of similar rating.
40 CFR 280.104 - Local government bond rating test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Local government bond rating test. 280... STORAGE TANKS (UST) Financial Responsibility § 280.104 Local government bond rating test. (a) A general purpose local government owner or operator and/or local government serving as a guarantor may satisfy the...
21 CFR 864.6700 - Erythrocyte sedimentation rate test.
Code of Federal Regulations, 2010 CFR
2010-04-01
... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...
21 CFR 864.6700 - Erythrocyte sedimentation rate test.
Code of Federal Regulations, 2014 CFR
2014-04-01
... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...
21 CFR 864.6700 - Erythrocyte sedimentation rate test.
Code of Federal Regulations, 2012 CFR
2012-04-01
... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...
21 CFR 864.6700 - Erythrocyte sedimentation rate test.
Code of Federal Regulations, 2011 CFR
2011-04-01
... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...
21 CFR 864.6700 - Erythrocyte sedimentation rate test.
Code of Federal Regulations, 2013 CFR
2013-04-01
... sedimentation rate test. (a) Identification. An erythrocyte sedimentation rate test is a device that measures the length of time required for the red cells in a blood sample to fall a specified distance or a... device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter...
The optimal power puzzle: scrutiny of the monotone likelihood ratio assumption in multiple testing.
Cao, Hongyuan; Sun, Wenguang; Kosorok, Michael R
2013-01-01
In single hypothesis testing, power is a non-decreasing function of type I error rate; hence it is desirable to test at the nominal level exactly to achieve optimal power. The puzzle lies in the fact that for multiple testing, under the false discovery rate paradigm, such a monotonic relationship may not hold. In particular, exact false discovery rate control may lead to a less powerful testing procedure if a test statistic fails to fulfil the monotone likelihood ratio condition. In this article, we identify different scenarios wherein the condition fails and give caveats for conducting multiple testing in practical settings.
Reliability of psychophysiological responses across multiple motion sickness stimulation tests
NASA Technical Reports Server (NTRS)
Stout, C. S.; Toscano, W. B.; Cowings, P. S.
1995-01-01
Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.
Vecellio, Elia; Georgiou, Andrew; Toouli, George; Eigenstetter, Alex; Li, Ling; Wilson, Roger; Westbrook, Johanna I
2013-01-01
Electronic test ordering, via the Electronic Medical Record (EMR), which incorporates computerised provider order entry (CPOE), is widely considered as a useful tool to support appropriate pathology test ordering. Diagnosis-related groups (DRGs) are clinically meaningful categories that allow comparisons in pathology utilisation by patient groups by controlling for many potentially confounding variables. This study used DRG data linked to pathology test data to examine changes in rates of test ordering across four years coinciding with the introduction of an EMR in six hospitals in New South Wales, Australia. This method generated a list of high pathology utilisation DRGs. We investigated patients with a Chest pain DRG to examine whether tests rates changed for specific test groups by hospital emergency department (ED) pre- and post-EMR. There was little change in testing rates between EDs or between time periods pre- and post-EMR. This is a valuable method for monitoring the impact of EMR and clinical decision support on test order rates.
Modeling the Declining Positivity Rates for Human Immunodeficiency Virus Testing in New York State.
Martin, Erika G; MacDonald, Roderick H; Smith, Lou C; Gordon, Daniel E; Lu, Tao; OʼConnell, Daniel A
2015-01-01
New York health care providers have experienced declining percentages of positive human immunodeficiency virus (HIV) tests among patients. Furthermore, observed positivity rates are lower than expected on the basis of the national estimate that one-fifth of HIV-infected residents are unaware of their infection. We used mathematical modeling to evaluate whether this decline could be a result of declining numbers of HIV-infected persons who are unaware of their infection, a measure that is impossible to measure directly. A stock-and-flow mathematical model of HIV incidence, testing, and diagnosis was developed. The model includes stocks for uninfected, infected and unaware (in 4 disease stages), and diagnosed individuals. Inputs came from published literature and time series (2006-2009) for estimated new infections, newly diagnosed HIV cases, living diagnosed cases, mortality, and diagnosis rates in New York. Primary model outcomes were the percentage of HIV-infected persons unaware of their infection and the percentage of HIV tests with a positive result (HIV positivity rate). In the base case, the estimated percentage of unaware HIV-infected persons declined from 14.2% in 2006 (range, 11.9%-16.5%) to 11.8% in 2010 (range, 9.9%-13.1%). The HIV positivity rate, assuming testing occurred independent of risk, was 0.12% in 2006 (range, 0.11%-0.15%) and 0.11% in 2010 (range, 0.10%-0.13%). The observed HIV positivity rate was more than 4 times the expected positivity rate based on the model. HIV test positivity is a readily available indicator, but it cannot distinguish causes of underlying changes. Findings suggest that the percentage of unaware HIV-infected New Yorkers is lower than the national estimate and that the observed HIV test positivity rate is greater than expected if infected and uninfected individuals tested at the same rate, indicating that testing efforts are appropriately targeting undiagnosed cases.
Hickson, Ford; Tomlin, Keith; Hargreaves, James; Bonell, Chris; Reid, David; Weatherburn, Peter
2015-02-01
Increasing HIV testing among men who have sex with men (MSM) is a major policy goal in the UK. Social marketing is a common intervention to increase testing uptake. We used an online panel of MSM to examine rates of HIV testing behaviour and the impact of a social marketing intervention on them. MSM in England were recruited to a longitudinal internet panel through community websites and a previous survey. Following an enrolment survey, respondents were invited to self-complete 13 surveys at monthly intervals throughout 2011. A unique alphanumeric code linked surveys for individuals. Rates of HIV testing were compared relative to prompted recognition of a multi-part media campaign aiming to normalise HIV testing. Of 3386 unique enrolments, 2047 respondents were included in the analysis, between them submitting 15,353 monthly surveys (equivalent to 1279 years of follow-up), and recording 1517 HIV tests taken, giving an annual rate of tests per participant of 1.19 (95% CI 1.13 to 1.25). Tests were highly clustered in individuals (61% reported no test during the study). Testing rates were higher in London, single men and those aged 25-34 years. Only 7.6% recognised the intervention when prompted. After controlling for sociodemographic characteristics and exposure to other health promotion campaigns, intervention recognition was not associated with increased likelihood of testing. Higher rates of testing were strongly associated with higher number of casual sexual partners and how recently men had HIV tested before study enrolment. This social marketing intervention was not associated with increased rates of HIV testing. More effective promotion of HIV testing is needed among MSM in England to reduce the average duration of undiagnosed infection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Hill, Kylie; Dolmage, Thomas E; Woon, Lynda; Coutts, Debbie; Goldstein, Roger; Brooks, Dina
2012-02-01
Field and laboratory-based tests are used to measure exercise capacity in people with COPD. A comparison of the cardiorespiratory responses to field tests, referenced to a laboratory test, is needed to appreciate the relative physiological demands. We sought to compare peak and submaximal cardiorespiratory responses to the 6-min walk test, incremental shuttle walk test and endurance shuttle walk test with a ramp cycle ergometer test (CET) in patients with COPD. Twenty-four participants (FEV(1) 50 ± 14%; 66.5 ± 7.7 years; 15 men) completed four sessions, separated by ≥24 h. During an individual session, participants completed either two 6-min walk tests, incremental shuttle walk tests, endurance shuttle walk tests using standardized protocols, or a single CET, wearing a portable gas analysis unit (Cosmed K4b(2)) which included measures of heart rate and arterial oxygen saturation (SpO(2)). Between tests, no difference was observed in the peak rate of oxygen uptake (F(3,69) = 1.2; P = 0.31), end-test heart rate (F(2,50) = 0.6; P = 0.58) or tidal volume (F(3,69) = 1.5; P = 0.21). Compared with all walking tests, the CET elicited a higher peak rate of carbon dioxide output (1173 ± 350 mL/min; F(3,62) = 4.8; P = 0.006), minute ventilation (48 ± 17 L/min; F(3,69) = 10.2; P < 0.001) and a higher end-test SpO(2) (95 ± 4%; F(3,63) = 24.9; P < 0.001). In patients with moderate COPD, field walking tests elicited a similar peak rate of oxygen uptake and heart rate as a CET, demonstrating that both self- and externally paced walking tests progress to high intensities. © 2011 The Authors. Respirology © 2011 Asian Pacific Society of Respirology.
Karr, Justin E; Garcia-Barrera, Mauricio A; Holdnack, James A; Iverson, Grant L
2018-01-01
Multivariate base rates allow for the simultaneous statistical interpretation of multiple test scores, quantifying the normal frequency of low scores on a test battery. This study provides multivariate base rates for the Delis-Kaplan Executive Function System (D-KEFS). The D-KEFS consists of 9 tests with 16 Total Achievement scores (i.e. primary indicators of executive function ability). Stratified by education and intelligence, multivariate base rates were derived for the full D-KEFS and an abbreviated four-test battery (i.e. Trail Making, Color-Word Interference, Verbal Fluency, and Tower Test) using the adult portion of the normative sample (ages 16-89). Multivariate base rates are provided for the full and four-test D-KEFS batteries, calculated using five low score cutoffs (i.e. ≤25th, 16th, 9th, 5th, and 2nd percentiles). Low scores occurred commonly among the D-KEFS normative sample, with 82.6 and 71.8% of participants obtaining at least one score ≤16th percentile for the full and four-test batteries, respectively. Intelligence and education were inversely related to low score frequency. The base rates provided herein allow clinicians to interpret multiple D-KEFS scores simultaneously for the full D-KEFS and an abbreviated battery of commonly administered tests. The use of these base rates will support clinicians when differentiating between normal variations in cognitive performance and true executive function deficits.
Statistical inference methods for two crossing survival curves: a comparison of methods.
Li, Huimin; Han, Dong; Hou, Yawen; Chen, Huilin; Chen, Zheng
2015-01-01
A common problem that is encountered in medical applications is the overall homogeneity of survival distributions when two survival curves cross each other. A survey demonstrated that under this condition, which was an obvious violation of the assumption of proportional hazard rates, the log-rank test was still used in 70% of studies. Several statistical methods have been proposed to solve this problem. However, in many applications, it is difficult to specify the types of survival differences and choose an appropriate method prior to analysis. Thus, we conducted an extensive series of Monte Carlo simulations to investigate the power and type I error rate of these procedures under various patterns of crossing survival curves with different censoring rates and distribution parameters. Our objective was to evaluate the strengths and weaknesses of tests in different situations and for various censoring rates and to recommend an appropriate test that will not fail for a wide range of applications. Simulation studies demonstrated that adaptive Neyman's smooth tests and the two-stage procedure offer higher power and greater stability than other methods when the survival distributions cross at early, middle or late times. Even for proportional hazards, both methods maintain acceptable power compared with the log-rank test. In terms of the type I error rate, Renyi and Cramér-von Mises tests are relatively conservative, whereas the statistics of the Lin-Xu test exhibit apparent inflation as the censoring rate increases. Other tests produce results close to the nominal 0.05 level. In conclusion, adaptive Neyman's smooth tests and the two-stage procedure are found to be the most stable and feasible approaches for a variety of situations and censoring rates. Therefore, they are applicable to a wider spectrum of alternatives compared with other tests.
Statistical Inference Methods for Two Crossing Survival Curves: A Comparison of Methods
Li, Huimin; Han, Dong; Hou, Yawen; Chen, Huilin; Chen, Zheng
2015-01-01
A common problem that is encountered in medical applications is the overall homogeneity of survival distributions when two survival curves cross each other. A survey demonstrated that under this condition, which was an obvious violation of the assumption of proportional hazard rates, the log-rank test was still used in 70% of studies. Several statistical methods have been proposed to solve this problem. However, in many applications, it is difficult to specify the types of survival differences and choose an appropriate method prior to analysis. Thus, we conducted an extensive series of Monte Carlo simulations to investigate the power and type I error rate of these procedures under various patterns of crossing survival curves with different censoring rates and distribution parameters. Our objective was to evaluate the strengths and weaknesses of tests in different situations and for various censoring rates and to recommend an appropriate test that will not fail for a wide range of applications. Simulation studies demonstrated that adaptive Neyman’s smooth tests and the two-stage procedure offer higher power and greater stability than other methods when the survival distributions cross at early, middle or late times. Even for proportional hazards, both methods maintain acceptable power compared with the log-rank test. In terms of the type I error rate, Renyi and Cramér—von Mises tests are relatively conservative, whereas the statistics of the Lin-Xu test exhibit apparent inflation as the censoring rate increases. Other tests produce results close to the nominal 0.05 level. In conclusion, adaptive Neyman’s smooth tests and the two-stage procedure are found to be the most stable and feasible approaches for a variety of situations and censoring rates. Therefore, they are applicable to a wider spectrum of alternatives compared with other tests. PMID:25615624
Racial Differences in Receipt of Chlamydia Testing Among Medicaid-Insured Women in 2013.
Patel, Chirag G; Chesson, Harrell W; Tao, Guoyu
2016-03-01
To estimate the percentage of young, sexually active Medicaid-insured women who were tested for chlamydia by age, race/ethnicity, and history of sexually transmitted disease (STD) diagnosis. We used the medical diagnostic and procedural codes from Truven Health MarketScan Medicaid claims data from 10 states in 2012 and 2013 to estimate the rates of chlamydia testing in 2013 and previous STD diagnosis (diagnosed in 2012) among Medicaid-insured women aged 15-25 years who were sexually active in 2013. We also used a logit model to assess the association between chlamydia testing and women's age, race/ethnicity, and previous STD diagnosis. Overall, among approximately 261,000 Medicaid-insured women aged 15-25 years in 2013 who were classified as sexually active, 50.2% were tested for chlamydia in 2013. The chlamydia testing rate was 45.6% for white women and 57.5% for black women. The chlamydia testing rate was 63.5% for women diagnosed as having an STD in 2012 and 46.8% for women not diagnosed as having an STD in 2012. The chlamydia testing rate was significantly (P < 0.05) associated with previous STD diagnosis, age, and race/ethnicity in our logit model. Higher chlamydia testing rates among black women can be explained in part by higher rates of previous STD diagnoses. Our finding that black women have the highest chlamydia testing rates is encouraging, as improved access to STD prevention services among racial/ethnic minorities can help to reduce racial/ethnic disparities in STDs. However, chlamydia screening remains an underused preventive health service for young women of all racial and ethnic groups.
Desai, Sunita; Jena, Anupam B
2016-12-14
To examine the effect on BRCA testing and mastectomy rates of a widely viewed 2013 New York Times editorial by public figure Angelina Jolie that endorsed BRCA testing and announced Jolie's decision to undergo preventive mastectomy. Observational study with difference-in-difference analysis. Commercially insured US population. Women aged 18-64 years with claims in the Truven MarketScan commercial claims database (n=9 532 836). Changes in BRCA testing rates in the 15 business days before versus after 14 May 2013 (editorial date) compared with the change in the same period in 2012; mastectomy rates in the months before and after publication, both overall and within 60 days of BRCA testing among women who were tested; national estimates of incremental tests and expenditures associated with Jolie's article in the 15 days after publication. Daily BRCA test rates increased immediately after the 2013 editorial, from 0.71 tests/100 000 women in the 15 business days before to 1.13 tests/100 000 women in the 15 business days after publication. In comparison, daily test rates were similar in the same period in 2012 (0.58/100 000 women in the 15 business days before 14 May versus 0.55/100 000 women in the 15 business days after), implying a difference-in-difference absolute daily increase of 0.45 tests/100 000 women or a 64% relative increase (P<0.001). The editorial was associated with an estimated increase of 4500 BRCA tests and $13.5m (£10.8m; €12.8) expenditure nationally among commercially insured adult women in those 15 days. Increased BRCA testing rates were sustained throughout 2013. Overall mastectomy rates remained unchanged in the months after publication, but 60 day mastectomy rates among women who had a BRCA test fell from 10% in the months before publication to 7% in the months after publication, suggesting that women who underwent tests as a result of to the editorial had a lower pre-test probability of having the BRCA mutation than women tested before the editorial. Celebrity endorsements can have a large and immediate effect on use of health services. Such announcements can be a low cost means of reaching a broad audience quickly, but they may not effectively target the subpopulations that are most at risk for the relevant underlying condition. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Investigating Barriers in HIV-Testing Oncology Patients: The IBITOP Study, Phase I
Merz, Laurent; Zimmermann, Stefan; Peters, Solange; Cavassini, Matthias
2016-01-01
Background. Although the prevalence of non-AIDS-defining cancers (non-ADCs) among people living with HIV is rising, we observed HIV testing rates below 5% at our oncology center, against a regional HIV prevalence of 0.2%–0.4%. We performed the Investigating Barriers in HIV-Testing Oncology Patients (IBITOP) study among oncology physicians and patients. Methods. Between July 1 and October 31, 2013, patients of unknown HIV status newly diagnosed with solid-organ non-ADCs referred to Lausanne University Hospital Oncology Service, Switzerland, were offered free HIV testing as part of their oncology work-up. The primary endpoints were (a) physician willingness to offer and patient acceptance of HIV testing and (b) physicians’ reasons for not offering testing. Results. Of 239 patients of unknown HIV status with a new non-ADC diagnosis, 43 (18%) were offered HIV testing, of whom 4 declined (acceptance rate: 39 of 43; 91%). Except for 21 patients tested prior to oncology consultation, 175 patients (of 239; 73%) were not offered testing. Testing rate declined among patients who were >70 years old (12% versus 30%; p = .04); no non-European patients were tested. Physicians gave reasons for not testing in 16% of cases, the main reason being patient follow-up elsewhere (10 patients; 5.7%). HIV testing during the IBITOP study increased the HIV testing rate to 18%. Conclusion. Although the IBITOP study increased HIV testing rates, most patients were not tested. Testing was low or nonexistent among individuals at risk of late HIV presentation (older patients and migrants). Barriers to testing appear to be physician-led, because patient acceptance of testing offered was very high (91%). In November 2013, the Swiss HIV testing recommendations were updated to propose testing in cancer patients. Phase II of the IBITOP study is examining the effect of these recommendations on HIV testing rates and focusing on physician-led testing barriers. Implications for Practice: Patients of unknown HIV status newly diagnosed with solid-organ non-AIDS-defining cancers were offered free HIV testing. Physician and patient barriers to HIV testing were examined. Most patients (82%) were not offered testing, and testing of individuals at risk of late HIV presentation (older patients and migrants) was low or nonexistent. Conversely, patient acceptance of testing offered was very high (91%), suggesting that testing barriers in this setting are physician-led. Since this study, the Swiss HIV testing recommendations now advise testing cancer patients before chemotherapy. Phase II of the Investigating Barriers in HIV-Testing Oncology Patients study is examining the effect of these recommendations on testing rates and physician barriers. PMID:27440062
NASA Technical Reports Server (NTRS)
Carts, M. A.; Marshall, P. W.; Reed, R.; Curie, S.; Randall, B.; LaBel, K.; Gilbert, B.; Daniel, E.
2006-01-01
Serial Bit Error Rate Testing under radiation to characterize single particle induced errors in high-speed IC technologies generally involves specialized test equipment common to the telecommunications industry. As bit rates increase, testing is complicated by the rapidly increasing cost of equipment able to test at-speed. Furthermore as rates extend into the tens of billions of bits per second test equipment ceases to be broadband, a distinct disadvantage for exploring SEE mechanisms in the target technologies. In this presentation the authors detail the testing accomplished in the CREST project and apply the knowledge gained to establish a set of guidelines suitable for designing arbitrarily high speed radiation effects tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other..., App. B Appendix B to Part 173—Procedure for Testing Chemical Compatibility and Rate of Permeation in... °C. (64 °F.) b. Test Method 2: 28 days at a temperature no lower than 50 °C. (122 °F.) c. Test Method...
Somatic and gastrointestinal in vivo biotransformation rates of hydrophobic chemicals in fish.
Lo, Justin C; Campbell, David A; Kennedy, Christopher J; Gobas, Frank A P C
2015-10-01
To improve current bioaccumulation assessment methods, a methodology is developed, applied, and investigated for measuring in vivo biotransformation rates of hydrophobic organic substances in the body (soma) and gastrointestinal tract of the fish. The method resembles the Organisation for Economic Co-operation and Development (OECD) 305 dietary bioaccumulation test but includes reference chemicals to determine both somatic and gastrointestinal biotransformation rates of test chemicals. Somatic biotransformation rate constants for the test chemicals ranged between 0 d(-1) and 0.38 (standard error [SE] 0.03)/d(-1) . Gastrointestinal biotransformation rate constants varied from 0 d(-1) to 46 (SE 7) d(-1) . Gastrointestinal biotransformation contributed more to the overall biotransformation in fish than somatic biotransformation for all test substances but 1. Results suggest that biomagnification tests can reveal the full extent of biotransformation in fish. The common presumption that the liver is the main site of biotransformation may not apply to many substances exposed through the diet. The results suggest that the application of quantitative structure-activity relationships (QSARs) for somatic biotransformation rates and hepatic in vitro models to assess the effect of biotransformation on bioaccumulation can underestimate biotransformation rates and overestimate the biomagnification potential of chemicals that are biotransformed in the gastrointestinal tract. With some modifications, the OECD 305 test can generate somatic and gastrointestinal biotransformation data to develop biotransformation QSARs and test in vitro-in vivo biotransformation extrapolation methods. © 2015 SETAC.
A Bayesian hierarchical model with novel prior specifications for estimating HIV testing rates
An, Qian; Kang, Jian; Song, Ruiguang; Hall, H. Irene
2016-01-01
Human immunodeficiency virus (HIV) infection is a severe infectious disease actively spreading globally, and acquired immunodeficiency syndrome (AIDS) is an advanced stage of HIV infection. The HIV testing rate, that is, the probability that an AIDS-free HIV infected person seeks a test for HIV during a particular time interval, given no previous positive test has been obtained prior to the start of the time, is an important parameter for public health. In this paper, we propose a Bayesian hierarchical model with two levels of hierarchy to estimate the HIV testing rate using annual AIDS and AIDS-free HIV diagnoses data. At level one, we model the latent number of HIV infections for each year using a Poisson distribution with the intensity parameter representing the HIV incidence rate. At level two, the annual numbers of AIDS and AIDS-free HIV diagnosed cases and all undiagnosed cases stratified by the HIV infections at different years are modeled using a multinomial distribution with parameters including the HIV testing rate. We propose a new class of priors for the HIV incidence rate and HIV testing rate taking into account the temporal dependence of these parameters to improve the estimation accuracy. We develop an efficient posterior computation algorithm based on the adaptive rejection metropolis sampling technique. We demonstrate our model using simulation studies and the analysis of the national HIV surveillance data in the USA. PMID:26567891
Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome
Wald, Nicholas J.; Bestwick, Jonathan P.
2013-01-01
Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014
Test Scores, Dropout Rates, and Transfer Rates as Alternative Indicators of High School Performance
ERIC Educational Resources Information Center
Rumberger, Russell W.; Palardy, Gregory J.
2005-01-01
This study investigated the relationships among several different indicators of high school performance: test scores, dropout rates, transfer rates, and attrition rates. Hierarchical linear models were used to analyze panel data from a sample of 14,199 students who took part in the National Education Longitudinal Survey of 1988. The results…
A Comparison of Validity Rates between Paper-and-Pencil and Computerized Testing with the MMPI-2
ERIC Educational Resources Information Center
Blazek, Nicole L.; Forbey, Johnathan D.
2011-01-01
Although the use of computerized testing in psychopathology assessment has increased in recent years, limited research has examined the impact of this format in terms of potential differences in test validity rates. The current study explores potential differences in the rates of valid and invalid Minnesota Multiphasic Personality Inventory--2…
Code of Federal Regulations, 2010 CFR
2010-01-01
..., the water consumption flow rate of commercial prerinse spray valves. (b) Testing and Calculations. The test procedure to determine the water consumption flow rate for prerinse spray valves, expressed in... the previous step. Round the final water consumption value to one decimal place as follows: (1) A...
Rapid-Rate Compression Testing of Sheet Materials at High Temperatures
NASA Technical Reports Server (NTRS)
Bernett, E. C.; Gerberich, W. W.
1961-01-01
This Report describes the test equipment that was developed and the procedures that were used to evaluate structural sheet-material compression properties at preselected constant strain rates and/or loads. Electrical self-resistance was used to achieve a rapid heating rate of 200 F/sec. Four materials were tested at maximum temperatures which ranged from 600 F for the aluminum alloy to 2000 F for the Ni-Cr-Co iron-base alloy. Tests at 0.1, 0.001, and 0.00001 in./in./sec showed that strain rate has a major effect on the measured strength, especially at the high temperatures. The tests, under conditions of constant temperature and constant compression stress, showed that creep deformation can be a critical factor even when the time involved is on the order of a few seconds or less. The theoretical and practical aspects of rapid-rate compression testing are presented, and suggestions are made regarding possible modifications of the equipment which would improve the over-all capabilities.
Bilgin, Suleyman; Arslan, Evren; Elmas, Onur; Yildiz, Sedat; Colak, Omer H; Bilgin, Gurkan; Koyuncuoglu, Hasan Rifat; Akkus, Selami; Comlekci, Selcuk; Koklukaya, Etem
2015-12-01
Fibromyalgia syndrome (FMS) is identified by widespread musculoskeletal pain, sleep disturbance, nonrestorative sleep, fatigue, morning stiffness and anxiety. Anxiety is very common in Fibromyalgia and generally leads to a misdiagnosis. Self-rated Beck Anxiety Inventory (BAI) and doctor-rated Hamilton Anxiety Inventory (HAM-A) are frequently used by specialists to determine anxiety that accompanies fibromyalgia. However, these semi-quantitative anxiety tests are still subjective as the tests are scored using doctor-rated or self-rated scales. In this study, we investigated the relationship between heart rate variability (HRV) frequency subbands and anxiety tests. The study was conducted with 56 FMS patients and 34 healthy controls. BAI and HAM-A test scores were determined for each participant. ECG signals were then recruited and 71 HRV subbands were obtained from these ECG signals using Wavelet Packet Transform (WPT). The subbands and anxiety tests scores were analyzed and compared using multilayer perceptron neural networks (MLPNN). The results show that a HRV high frequency (HF) subband in the range of 0.15235Hz to 0.40235Hz, is correlated with BAI scores and another HRV HF subband, frequency range of 0.15235Hz to 0.28907Hz is correlated with HAM-A scores. The overall accuracy is 91.11% for HAM-A and 90% for BAI with MLPNN analysis. Doctor-rated or self-rated anxiety tests should be supported with quantitative and more objective methods. Our results show that the HRV parameters will be able to support the anxiety tests in the clinical evaluation of fibromyalgia. In other words, HRV parameters can potentially be used as an auxiliary diagnostic method in conjunction with anxiety tests. Copyright © 2015 Elsevier Ltd. All rights reserved.
Resistance to Soybean Aphid Among Soybean Lines, Growth-chamber Tests, 2006 Through 2008
USDA-ARS?s Scientific Manuscript database
We tested for resistance to the soybean aphid (SBA, Aphis glycines) among several soybean lines, and rated lines as resistant or susceptible in seven tests. The ratings of plants with respect to SBA infestation differed among lines in all tests. Kosamame (PI 171451, test II), Bhart (PI 165989, tes...
Accelerated Testing Methodology Developed for Determining the Slow Crack Growth of Advanced Ceramics
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Gyekenyesi, John P.
1998-01-01
Constant stress-rate ("dynamic fatigue") testing has been used for several decades to characterize the slow crack growth behavior of glass and structural ceramics at both ambient and elevated temperatures. The advantage of such testing over other methods lies in its simplicity: strengths are measured in a routine manner at four or more stress rates by applying a constant displacement or loading rate. The slow crack growth parameters required for component design can be estimated from a relationship between strength and stress rate. With the proper use of preloading in constant stress-rate testing, test time can be reduced appreciably. If a preload corresponding to 50 percent of the strength is applied to the specimen prior to testing, 50 percent of the test time can be saved as long as the applied preload does not change the strength. In fact, it has been a common, empirical practice in the strength testing of ceramics or optical fibers to apply some preloading (<40 percent). The purpose of this work at the NASA Lewis Research Center is to study the effect of preloading on measured strength in order to add a theoretical foundation to the empirical practice.
Implementing a routine, voluntary HIV testing program in a Massachusetts county prison.
Liddicoat, Rebecca V; Zheng, Hui; Internicola, Jeanne; Werner, Barbara G; Kazianis, Arthur; Golan, Yoav; Rubinstein, Eric P; Freedberg, Kenneth A; Walensky, Rochelle P
2006-11-01
Although U.S. prison inmates have higher rates of HIV infection than the general population, most inmates are not routinely tested for HIV infection at prison entry. The study objective was to implement a routine, voluntary HIV testing program in a Massachusetts county prison. During admission, inmates were given group HIV pre-test counseling and were subsequently offered private HIV testing. This intervention was compared to a control period during which HIV testing was provided only upon inmate or physician request. Between November 2004 and April 2005, 1,004 inmates met inclusion criteria and were offered routine, voluntary HIV testing. Of these, 734 (73.1%) accepted, 2 (0.3%) were HIV-infected, and 457 (45.5%) had been tested for HIV in the previous year. The testing rate of 73.1% was significantly increased from the rate of 18.0% (318 of 1,723) during the control period (p<0.001). Among the inmates tested for HIV in the prior year, 78.2% had received their last HIV test in the prison setting. Careful attention should be paid to prevent redundancy of testing efforts in the prison population. Implementing a routine HIV testing program among prison inmates greatly increased testing rates compared to on-request testing.
Experimental investigation of time dependent behavior of welded Topopah Spring Tuff
NASA Astrophysics Data System (ADS)
Ma, Lumin
Four types of laboratory tests have been performed. Specimens were attained from four lithophysal zones of the welded Topopah Spring Tuff unit at Yucca Mountain, Nevada: upper lithophysal, middle nonlithophysal, lower lithophysal and lower nonlithophysal zones. Two types of tests are conducted to study time-dependent behavior: constant strain rate and creep tests. Sixty-five specimens from the middle nonlithophysal zone were tested at six strain rates: 10-2, 10-4, 10-5, 10-6, 10-7, and 10-8 s-1. Test durations range from 2 seconds to 7 days. Fourteen specimens from middle nonlithophysal, lower lithophysal and lower nonlithophysal zones are creep tested by incremental stepwise loading. All the tests are conducted under uniaxial compression at room temperature and humidity. Specimens exhibit extremely brittle fracture and fail by axial splitting, and show very little dilatancy if any. It is assumed that microfracturing dominates the inelastic deformation and failure of the tuff. Nonlinear regression is applied to the results of the constant strain rate tests to estimate the relations between peak strength, peak axial strain, secant modulus and strain rate. All three these parameters decrease with a decrease of strain rate and follow power functions: sigmapeak = 271.37 3˙0.0212 0.0212, epsilonpeak = 0.006 3˙0.0083 , ES = 41985.4 3˙0.015 . Secant modulus is introduced mainly as a tool to analyze strain rate dependent axial strain. Two threshold stresses define creep behavior. Below about 50% of peak strength, a specimen does not creep. Above about 94% of peak strength, a specimen creeps at an accelerating rate. Between the two threshold stresses, a power law relates strain rate and stress. One hundred fifty-eight Brazilian (Indirect tensile splitting) tests have been performed at six different constant strain rates. Nineteen lithophysal specimens were tested in uniaxial compression to study their fracture pattern. These specimens have a far less brittle failure mode. They slowly crumble, collapse, and maintain considerable relative strength beyond the peak. Due to the presence of multiple relatively large lithophysal cavities, they are far weaker and softer than the nonlithophysal specimens.
Biofeedback-assisted relaxation training to decrease test anxiety in nursing students.
Prato, Catherine A; Yucha, Carolyn B
2013-01-01
Nursing students experiencing debilitating test anxiety may be unable to demonstrate their knowledge and have potential for poor academic performance. A biofeedback-assisted relaxation training program was created to reduce test anxiety. Anxiety was measured using Spielberger's Test Anxiety Inventory and monitoring peripheral skin temperature, pulse, and respiration rates during the training. Participants were introduced to diaphragmatic breathing, progressive muscle relaxation, and autogenic training. Statistically significant changes occurred in respiratory rates and skin temperatures during the diaphragmatic breathing session; respiratory rates and peripheral skin temperatures during progressive muscle relaxation session; respiratory and pulse rates, and peripheral skin temperatures during the autogenic sessions. No statistically significant difference was noted between the first and second TAI. Subjective test anxiety scores of the students did not decrease by the end of training. Autogenic training session was most effective in showing a statistically significant change in decreased respiratory and pulse rates and increased peripheral skin temperature.
Relation between gastric emptying rate and energy intake in children compared with adults.
Maes, B D; Ghoos, Y F; Geypens, B J; Hiele, M I; Rutgeerts, P J
1995-01-01
Measurement of gastric emptying rate of solids in children is difficult because the available methods are either invasive or induce a substantial radiation burden. In this study the newly developed 13C octanoic acid breath test was used to examine the gastric emptying rate of solids and milk in healthy children and to compare gastric emptying in children and adults. Fifteen healthy children and three groups of nine healthy adults were studied, using three different test meals labelled with 50 mg of 13C octanoic acid: a low caloric pancake (150 kcal), a high caloric pancake (250 kcal), and 210 ml of milk (134 kcal). Breath samples were taken before and at regular intervals after ingestion of the test meal, and analysed by isotope ratio mass spectrometry. The gastric emptying parameters were derived from the 13CO2 excretion curves by non-linear regression analysis. No significant difference was found between children and adults in the emptying rate of the low caloric solid test meal. In children as well as in adults, increasing the energy content of the solid meal resulted in a significantly slower emptying rate. The milk test meal, however, was emptied at a faster rate in adults and at slower rate in children compared with the low caloric solid test meal. Moreover, the emptying rate of milk in children was significantly slower than in adults. In conclusion, a similar gastric emptying rate of solids but a slower emptying of full cream milk was shown in children of school age compared with adults, using the non-radioactive 13C octanoic acid breath test. PMID:7883214
Muscat, Kristina M; Kotrach, Houssam G; Wilkinson-Maitland, Courtney A; Schaeffer, Michele R; Mendonca, Cassandra T; Jensen, Dennis
2015-11-01
In a randomized cross-over study of 15 healthy men aged 20-30 years, we compared physiological and perceptual responses during treadmill and cycle exercise test protocols matched for increments in work rate - the source of increased locomotor muscle metabolic and contractile demands. The rates of O2 consumption and CO2 production were higher at the peak of treadmill versus cycle testing (p ≤ 0.05). Nevertheless, work rate, minute ventilation, tidal volume (VT), breathing frequency (fR), inspiratory capacity (IC), inspiratory reserve volume (IRV), tidal esophageal (Pes,tidal) and transdiaphragmatic pressure swings (Pdi,tidal), peak expiratory gastric pressures (Pga,peak), the root mean square of the diaphragm electromyogram (EMGdi,rms) expressed as a percentage of maximum EMGdi,rms (EMGdi,rms%max), and dyspnea ratings were similar at the peak of treadmill versus cycle testing (p > 0.05). Ratings of leg discomfort were higher at the peak of cycle versus treadmill exercise (p ≤ 0.05), even though peak O2 consumption was lower during cycling. Oxygen consumption, CO2 production, minute ventilation, fR, Pes,tidal, Pdi,tidal and Pga,peak were higher (p ≤ 0.05), while VT, IC, IRV, EMGdi,rms%max, and ratings of dyspnea and leg discomfort were similar (p > 0.05) at all or most submaximal work rates during treadmill versus cycle exercise. Our findings highlight important differences (and similarities) in physiological and perceptual responses at maximal and submaximal work rates during incremental treadmill and cycle exercise testing protocols. The lack of effect of exercise test modality on peak work rate advocates for the use of this readily available parameter to optimize training intensity determination, regardless of exercise training mode.
Bakker, Marjan; Wicherts, Jelte M
2014-09-01
In psychology, outliers are often excluded before running an independent samples t test, and data are often nonnormal because of the use of sum scores based on tests and questionnaires. This article concerns the handling of outliers in the context of independent samples t tests applied to nonnormal sum scores. After reviewing common practice, we present results of simulations of artificial and actual psychological data, which show that the removal of outliers based on commonly used Z value thresholds severely increases the Type I error rate. We found Type I error rates of above 20% after removing outliers with a threshold value of Z = 2 in a short and difficult test. Inflations of Type I error rates are particularly severe when researchers are given the freedom to alter threshold values of Z after having seen the effects thereof on outcomes. We recommend the use of nonparametric Mann-Whitney-Wilcoxon tests or robust Yuen-Welch tests without removing outliers. These alternatives to independent samples t tests are found to have nominal Type I error rates with a minimal loss of power when no outliers are present in the data and to have nominal Type I error rates and good power when outliers are present. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Increasing chlamydia test of re-infection rates using SMS reminders and incentives.
Downing, Sandra Gaye; Cashman, Colette; McNamee, Heather; Penney, Debbie; Russell, Darren B; Hellard, Margaret E
2013-02-01
Clients diagnosed and treated for Chlamydia trachomatis are a recognised high-risk group for subsequent infection. An estimated 8% of clients treated for chlamydia at Cairns Sexual Health Service return for re-testing within the recommended 3-4-month period. There is no recall or reminder system in place. This study assesses the effectiveness of using short messaging service (SMS) reminders with and without incentive payments to increase re-testing rates. Eligible consenting clients were randomly allocated to one of three groups. Group 1 (controls) received the standard advice from the clinician to return for re-testing in 3-4 months. Group 2 received the standard advice and an SMS reminder at 10-12 weeks post-treatment. Group 3 received the standard advice and the SMS reminder, which also offered an incentive payment on clinic attendance. 32 participants were recruited to groups 1 and 2 and 30 participants to group 3. 62 SMS reminders were sent with 13 (21.0%) reported as undelivered. Re-testing rates were 6.3%, 28.1% and 26.7% for groups 1, 2 and 3, respectively. SMS reminders with or without an incentive payment increased re-testing rates in our clients who were diagnosed and treated for chlamydia. However, re-testing remained less than ideal, and the high rate of undelivered SMS reminders suggest that this intervention alone will not achieve desired re-testing rates and that a range of strategies will be required to increase re-testing in this population.
Affected sib pair tests in inbred populations.
Liu, W; Weir, B S
2004-11-01
The affected-sib-pair (ASP) method for detecting linkage between a disease locus and marker loci was first established 50 years ago, and since then numerous modifications have been made. We modify two identity-by-state (IBS) test statistics of Lange (Lange, 1986a, 1986b) to allow for inbreeding in the population. We evaluate the power and false positive rates of the modified tests under three disease models, using simulated data. Before estimating false positive rates, we demonstrate that IBS tests are tests of both linkage and linkage disequilibrium between marker and disease loci. Therefore, the null hypothesis of IBS tests should be no linkage and no LD. When the population inbreeding coefficient is large, the false positive rates of Lange's tests become much larger than the nominal value, while those of our modified tests remain close to the nominal value. To estimate power with a controlled false positive rate, we choose the cutoff values based on simulated datasets under the null hypothesis, so that both Lange's tests and the modified tests generate same false positive rate. The powers of Lange's z-test and our modified z-test are very close and do not change much with increasing inbreeding. The power of the modified chi-square test also stays stable when the inbreeding coefficient increases. However, the power of Lange's chi-square test increases with increasing inbreeding, and is larger than that of our modified chi-square test for large inbreeding coefficients. The power is high under a recessive disease model for both Lange's tests and the modified tests, though the power is low for additive and dominant disease models. Allowing for inbreeding is therefore appropriate, at least for diseases known to be recessive.
Observations on the predictive value of short-term stake tests
Stan Lebow; Bessie Woodward; Patricia Lebow
2008-01-01
This paper compares average ratings of test stakes after 3, 4, 5, and 7 years exposure to their subsequent ratings after 11 years. Average ratings from over 200 treatment groups exposed in plots in southern Mississippi were compared to average ratings of a reference preservative. The analysis revealed that even perfect ratings after three years were not a reliable...
Luetsch, Karen; Burrows, Judith
2016-10-14
Graduate and post-graduate education for health professionals is increasingly delivered in an e-learning environment, where automated, continuous formative testing with integrated feedback can guide students' self-assessment and learning. Asking students to rate the certainty they assign to the correctness of their answers to test questions can potentially provide deeper insights into the success of teaching, with test results informing course designers whether learning outcomes have been achieved. It may also have implications for decision making in clinical practice. A study of pre-and post-tests for five study modules was designed to evaluate the teaching and learning within a pharmacotherapeutic course in an online postgraduate clinical pharmacy program. Certainty based marking of multiple choice questions (MCQ) was adapted for formative pre- and post-study module testing by asking students to rate their certainty of correctness of MCQ answers. Paired t-tests and a coding scheme were used to analyse changes in answers and certainty between pre-and post-tests. A survey evaluated students' experience with the novel formative testing design. Twenty-nine pharmacists enrolled in the postgraduate program participated in the study. Overall 1315 matched pairs of MCQ answers and certainty ratings between pre- and post-module tests were available for evaluation. Most students identified correct answers in post-tests and increased their certainty compared to pre-tests. Evaluation of certainty ratings in addition to correctness of answers identified MCQs and topic areas for revision to course designers. A survey of students showed that assigning certainty ratings to their answers assisted in structuring and focusing their learning throughout online study modules, facilitating identification of areas of uncertainty and gaps in their clinical knowledge. Adding certainty ratings to MCQ answers seems to engage students with formative testing and feedback and focus their learning in a web-based postgraduate pharmacy course. It also offers deeper insight into the successful delivery of online course content, identifying areas for improvement of teaching and content delivery as well as test question design.
NASA Technical Reports Server (NTRS)
Williams, R. E.; Kruger, R.
1980-01-01
Estimation procedures are described for measuring component failure rates, for comparing the failure rates of two different groups of components, and for formulating confidence intervals for testing hypotheses (based on failure rates) that the two groups perform similarly or differently. Appendix A contains an example of an analysis in which these methods are applied to investigate the characteristics of two groups of spacecraft components. The estimation procedures are adaptable to system level testing and to monitoring failure characteristics in orbit.
Fuel cladding behavior under rapid loading conditions
NASA Astrophysics Data System (ADS)
Yueh, K.; Karlsson, J.; Stjärnsäter, J.; Schrire, D.; Ledergerber, G.; Munoz-Reja, C.; Hallstadius, L.
2016-02-01
A modified burst test (MBT) was used in an extensive test program to characterize fuel cladding failure behavior under rapid loading conditions. The MBT differs from a normal burst test with the use of a driver tube to simulate the expansion of a fuel pellet, thereby producing a partial strain driven deformation condition similar to that of a fuel pellet expansion in a reactivity insertion accident (RIA). A piston/cylinder assembly was used to pressurize the driver tube. By controlling the speed and distance the piston travels the loading rate and degree of sample deformation could be controlled. The use of a driver tube with a machined gauge section localizes deformation and allows for continuous monitoring of the test sample diameter change at the location of maximum hoop strain, during each test. Cladding samples from five irradiated fuel rods were tested between 296 and 553 K and loading rates from 1.5 to 3.5/s. The test rods included variations of Zircaloy-2 with different liners and ZIRLO, ranging in burn-up from 41 to 74 GWd/MTU. The test results show cladding ductility is strongly temperature and loading rate dependent. Zircaloy-2 cladding ductility degradation due to operational hydrogen pickup started to recover at approximately 358 K for test condition used in the study. This recovery temperature is strongly loading rate dependent. At 373 K, ductility recovery was small for loading rates less than 8 ms equivalent RIA pulse width, but longer than 8 ms the ductility recovery increased exponentially with increasing pulse width, consistent with literature observations of loading rate dependent brittle-to-ductile (BTD) transition temperature. The cladding ductility was also observed to be strongly loading rate/pulse width dependent for BWR cladding below the BTD temperature and Pressurized Water Reactor (PWR) cladding at both 296 and 553 K.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the contingent price sale agreement at a rate equal to or greater than the applicable prescribed test... stated below the applicable test rate, or interest is stated under a payment recharacterization provision... section 483 test rate, there is no internal interest under the agreement. The stated maximum selling price...
ERIC Educational Resources Information Center
Schochet, Peter Z.; Chiang, Hanley S.
2010-01-01
This paper addresses likely error rates for measuring teacher and school performance in the upper elementary grades using value-added models applied to student test score gain data. Using realistic performance measurement system schemes based on hypothesis testing, we develop error rate formulas based on OLS and Empirical Bayes estimators.…
Highlights of the high-temperature falling particle receiver project: 2012 - 2016
NASA Astrophysics Data System (ADS)
Ho, C. K.; Christian, J.; Yellowhair, J.; Jeter, S.; Golob, M.; Nguyen, C.; Repole, K.; Abdel-Khalik, S.; Siegel, N.; Al-Ansary, H.; El-Leathy, A.; Gobereit, B.
2017-06-01
A 1 MWt continuously recirculating falling particle receiver has been demonstrated at Sandia National Laboratories. Free-fall and obstructed-flow receiver designs were tested with particle mass flow rates of ˜1 - 7 kg/s and average irradiances up to 1,000 suns. Average particle outlet temperatures exceeded 700 °C for the free-fall tests and reached nearly 800 °C for the obstructed-flow tests, with peak particle temperatures exceeding 900 °C. High particle heating rates of ˜50 to 200 °C per meter of illuminated drop length were achieved for the free-fall tests with mass flow rates ranging from 1 - 7 kg/s and for average irradiances up to ˜ 700 kW/m2. Higher temperatures were achieved at the lower particle mass flow rates due to less shading. The obstructed-flow design yielded particle heating rates over 300 °C per meter of illuminated drop length for mass flow rates of 1 - 3 kg/s for irradiances up to ˜1,000 kW/m2. The thermal efficiency was determined to be ˜60 - 70% for the free-falling particle tests and up to ˜80% for the obstructed-flow tests. Challenges encountered during the tests include particle attrition and particle loss through the aperture, reduced particle mass flow rates at high temperatures due to slot aperture narrowing and increased friction, and deterioration of the obstructed-flow structures due to wear and oxidation. Computational models were validated using the test data and will be used in future studies to design receiver configurations that can increase the thermal efficiency.
Preliminary test results for Li-SOCl2 high-rate D cells
NASA Technical Reports Server (NTRS)
Bragg, Bobby J.; Johnson, Paul
1992-01-01
The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.
Preliminary test results for Li-SOCl2 high-rate D cells
NASA Astrophysics Data System (ADS)
Bragg, Bobby J.; Johnson, Paul
1992-02-01
The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.
Advanced Nanoindentation Testing for Studying Strain-Rate Sensitivity and Activation Volume
NASA Astrophysics Data System (ADS)
Maier-Kiener, Verena; Durst, Karsten
2017-11-01
Nanoindentation became a versatile tool for testing local mechanical properties beyond hardness and modulus. By adapting standard nanoindentation test methods, simple protocols capable of probing thermally activated deformation processes can be accomplished. Abrupt strain-rate changes within one indentation allow determining the strain-rate dependency of hardness at various indentation depths. For probing lower strain-rates and excluding thermal drift influences, long-term creep experiments can be performed by using the dynamic contact stiffness for determining the true contact area. From both procedures hardness and strain-rate, and consequently strain-rate sensitivity and activation volume can be reliably deducted within one indentation, permitting information on the locally acting thermally activated deformation mechanism. This review will first discuss various testing protocols including possible challenges and improvements. Second, it will focus on different examples showing the direct influence of crystal structure and/or microstructure on the underlying deformation behavior in pure and highly alloyed material systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westra, C.; Forslund, C.; Field, I.
This report summarizes the data from the semiannual reports on fitness-for-duty programs submitted to the NRC by utilities for two reporting periods: January 1 through June 30, 1993, and July 1 through December 31, 1993. During 1993, licensees reported that they had conducted 242,966 tests for the presence of illegal drugs and alcohol. Of these tests, 1,512 (.62%) were confirmed positive. Positive test results varied by category of test and category of worker. The majority of positive test results (952) were obtained through pre-access testing. Of tests conducted on workers having access to the protected area, there were 341 positivemore » tests from random testing and 163 positive tests from for-cause testing. Follow-up testing of workers who had previously tested positive resulted in 56 positive tests. For-cause testing resulted in the highest percentage of positive tests; about 22 percent of for-cause tests were positive. This compares with a positive test rate of 1.04 percent of pre-access tests and .23 percent of random tests. Positive test rates also varied by category of worker. When all types of tests are combined (pre-access, random, for-cause, and follow-up testing), short-term contractor personnel had the highest positive test rate at.97 percent. Licensee employees and long-term contractors had lower combined positive test rates (.25% and .21%, respectively). Of the substances tested, marijuana was responsible for the highest percentage of positive test results (49.56%), followed by cocaine (23.41 %) and alcohol (22.65%).« less
2009-04-01
would not be expected to have a very sgnficant effect on the TEG vapor concentraton. Tests of Natural Die Off Rate. Our normal meth- odology for...to get consstent results. For tests to measure the natural de-off rate of nflu- enza vruses, ths methodology could not be used because the durat...on of the test was too long, so an alternatve procedure was employed. In preparaton for an exper- mental test to measure the natural de-off rate
High-Strain-Rate Compression Testing of Ice
NASA Technical Reports Server (NTRS)
Shazly, Mostafa; Prakash, Vikas; Lerch, Bradley A.
2006-01-01
In the present study a modified split Hopkinson pressure bar (SHPB) was employed to study the effect of strain rate on the dynamic material response of ice. Disk-shaped ice specimens with flat, parallel end faces were either provided by Dartmouth College (Hanover, NH) or grown at Case Western Reserve University (Cleveland, OH). The SHPB was adapted to perform tests at high strain rates in the range 60 to 1400/s at test temperatures of -10 and -30 C. Experimental results showed that the strength of ice increases with increasing strain rates and this occurs over a change in strain rate of five orders of magnitude. Under these strain rate conditions the ice microstructure has a slight influence on the strength, but it is much less than the influence it has under quasi-static loading conditions. End constraint and frictional effects do not influence the compression tests like they do at slower strain rates, and therefore the diameter/thickness ratio of the samples is not as critical. The strength of ice at high strain rates was found to increase with decreasing test temperatures. Ice has been identified as a potential source of debris to impact the shuttle; data presented in this report can be used to validate and/or develop material models for ice impact analyses for shuttle Return to Flight efforts.
NASA Technical Reports Server (NTRS)
Northam, G. B.
1972-01-01
Instantaneous burning rate data for a polybutadiene acrylic acid propellant, containing 16 weight percent aluminum, were calculated from the pressure histories of a test motor with 96.77 sq cm of burning area and a 5.08-cm-thick propellant web. Additional acceleration tests were conducted with reduced propellant web thicknesses of 3.81, 2.54, and 1.27 cm. The metallic residue collected from the various web thickness tests was characterized by weight and shape and correlated with the instantaneous burning rate measurements. Rapid depressurization extinction tests were conducted in order that surface pitting characteristics due to localized increased burning rate could be correlated with the residue analysis and the instantaneous burning rate data. The acceleration-induced burning rate augmentation was strongly dependent on propellant distance burned, or burning time, and thus was transient in nature. The results from the extinction tests and the residue analyses indicate that the transient rate augmentation was highly dependent on local enhancement of the combustion zone heat feedback to the surface by the growth of molten residue particles on or just above the burning surface. The size, shape, and number density of molten residue particles, rather than the total residue weight, determined the acceleration-induced burning rate augmentation.
Understanding High Recession Rates of Carbon Ablators Seen in Shear Tests in an Arc Jet
NASA Technical Reports Server (NTRS)
Driver, David M.; Olson, Michael W.; Barnhardt, Michael D.; MacLean, Matthew
2010-01-01
High rates of recession in arc jet shear tests of Phenolic Impregnated Carbon Ablator (PICA) inspired a series of tests and analysis on FiberForm (a carbon preform used in the fabrication of PICA). Arc jet tests were performed on FiberForm in both air and pure nitrogen for stagnation and shear configurations. The nitrogen tests showed little or no recession, while the air tests of FiberForm showed recession rates similar to that of PICA (when adjusted for the difference in density). While mechanical erosion can not be ruled out, this is the first step in doing so. Analysis using a carbon oxidation boundary condition within DPLR was used to predict the recession rate of FiberForm. The analysis indicates that much of the anomalous recession behavior seen in shear tests may simply be an artifact of the non-flight like test configuration (copper upstream of the test article) a result of dissimilar enthalpy and oxygen concentration profiles on the copper. Shape change effects were also investigated and shown to be relatively small.
Layton, J Bradley; Kim, Yoonsang; Alexander, G Caleb; Emery, Sherry L
2017-03-21
Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. To investigate associations between televised DTCA and testosterone testing and initiation in the United States. Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009-2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004-1.008), initiation (RR, 1.007; 95% CI, 1.004-1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002-1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09-0.19), 0.05 new initiations (95% CI, 0.03-0.08), and 0.02 initiations without a recent test (95% CI, 0.01-0.03) per 10 000 men for each monthly ad exposure over the entire period. Among US men residing in the 75 designated market areas, regional exposure to televised direct-to-consumer advertising was associated with greater testosterone testing, new initiation, and initiation without recent testing.
A Bayesian hierarchical model with novel prior specifications for estimating HIV testing rates.
An, Qian; Kang, Jian; Song, Ruiguang; Hall, H Irene
2016-04-30
Human immunodeficiency virus (HIV) infection is a severe infectious disease actively spreading globally, and acquired immunodeficiency syndrome (AIDS) is an advanced stage of HIV infection. The HIV testing rate, that is, the probability that an AIDS-free HIV infected person seeks a test for HIV during a particular time interval, given no previous positive test has been obtained prior to the start of the time, is an important parameter for public health. In this paper, we propose a Bayesian hierarchical model with two levels of hierarchy to estimate the HIV testing rate using annual AIDS and AIDS-free HIV diagnoses data. At level one, we model the latent number of HIV infections for each year using a Poisson distribution with the intensity parameter representing the HIV incidence rate. At level two, the annual numbers of AIDS and AIDS-free HIV diagnosed cases and all undiagnosed cases stratified by the HIV infections at different years are modeled using a multinomial distribution with parameters including the HIV testing rate. We propose a new class of priors for the HIV incidence rate and HIV testing rate taking into account the temporal dependence of these parameters to improve the estimation accuracy. We develop an efficient posterior computation algorithm based on the adaptive rejection metropolis sampling technique. We demonstrate our model using simulation studies and the analysis of the national HIV surveillance data in the USA. Copyright © 2015 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, M. E.; Jones, T. M.; Miller, D. H.
Several Slurry-Fed Melt Rate Furnace (SMRF) tests with earlier projections of the Sludge Batch 4 (SB4) composition have been performed.1,2 The first SB4 SMRF test used Frits 418 and 320, however it was found after the test that the REDuction/OXidation (REDOX) correlation at that time did not have the proper oxidation state for manganese. Because the manganese level in the SB4 sludge was higher than previous sludge batches tested, the impact of the higher manganese oxidation state was greater. The glasses were highly oxidized and very foamy, and therefore the results were inconclusive. After resolving this REDOX issue, Frits 418,more » 425, and 503 were tested in the SMRF with the updated baseline SB4 projection. Based on dry-fed Melt Rate Furnace (MRF) tests and the above mentioned SMRF tests, two previous frit recommendations were made by the Savannah River National Laboratory (SRNL) for processing of SB4 in the Defense Waste Processing Facility (DWPF). The first was Frit 503 based on the June 2006 composition projections.3 The recommendation was changed to Frit 418 as a result of the October 2006 composition projections (after the Tank 40 decant was implemented as part of the preparation plan). However, the start of SB4 processing was delayed due to the control room consolidation outage and the repair of the valve box in the Tank 51 to Tank 40 transfer line. These delays resulted in changes to the projected SB4 composition. Due to the slight change in composition and based on preliminary dry-fed MRF testing, SRNL believed that Frit 510 would increase throughput in processing SB4 in DWPF. Frit 418, which was used in processing Sludge Batch 3 (SB3), was a viable candidate and available in DWPF. Therefore, it was used during the initial SB4 processing. Due to the potential for higher melt rates with Frit 510, SMRF tests with the latest SB4 composition (1298 canisters) and Frits 510 and 418 were performed at a targeted waste loading (WL) of 35%. The '1298 canisters' describes the number of equivalent canisters that would be produced from the beginning of the current contract period before SB3 is blended with SB4. The melt rate for the SMRF SB4/Frit 510 test was 14.6 grams/minute. Due to cold cap mounding problems with the SMRF SB4/Frit 418 feed at 50 weight % solids that prevented a melt rate determination, this feed was diluted to 45 weight % solids. The melt rate for this diluted feed was 8.9 grams/minute. A correction factor of 1.2 for estimating the melt rate at 50 weight % solids from 45 weight % solids test results (based on previous SMRF testing5) was then used to estimate a melt rate of 10.7 grams/minute for SB4/Frit 418 at 50 weight % solids. Therefore, the use of Frit 510 versus Frit 418 with SB4 resulted in a higher melt rate (14.6 versus an estimated 10.7 grams/minute). For reference, a previous SMRF test with SB3/Frit 418 feed at 35% waste loading and 50 weight % solids resulted in a melt rate of 14.1 grams/minute. Therefore, depending on the actual feed rheology, the use of Frit 510 with SB4 could result in similar melt rates as experienced with SB3/Frit 418 feed in the DWPF.« less
Failure Pressure and Leak Rate of Steam Generator Tubes With Stress Corrosion Cracks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majumdar, S.; Kasza, K.; Park, J.Y.
2002-07-01
This paper illustrates the use of an 'equivalent rectangular crack' approach to predict leak rates through laboratory generated stress corrosion cracks. A comparison between predicted and observed test data on rupture and leak rate from laboratory generated stress corrosion cracks are provided. Specimen flaws were sized by post-test fractography in addition to pre-test advanced eddy current technique. The test failure pressures and leak rates are shown to be closer to those predicted on the basis of fractography than on NDE. However, the predictions based on NDE results are encouraging, particularly because they have the potential to determine a more detailedmore » geometry of ligamentous cracks from which more accurate predictions of failure pressure and leak rate can be made in the future. (authors)« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-09
...--Non-Published Rates AGENCY: U.S. Postal Service\\TM\\. ACTION: Notice. SUMMARY: The Postal Service hereby gives notice of a market test for International Merchandise Return Service--Non-Published Rates in... Return Service (IMRS) Non-published Rate (NPR) experimental product on August 15, 2013. The Postal...
40 CFR 62.14635 - What operating limits must I meet and by when?
Code of Federal Regulations, 2012 CFR
2012-07-01
..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...
40 CFR 62.14635 - What operating limits must I meet and by when?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...
40 CFR 62.14635 - What operating limits must I meet and by when?
Code of Federal Regulations, 2014 CFR
2014-07-01
..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...
40 CFR 62.14635 - What operating limits must I meet and by when?
Code of Federal Regulations, 2010 CFR
2010-07-01
..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...
40 CFR 62.14635 - What operating limits must I meet and by when?
Code of Federal Regulations, 2013 CFR
2013-07-01
..., maximum charge rate is 110 percent of the average charge rate measured during the most recent performance... charge rate is 110 percent of the daily charge rate measured during the most recent performance test... during the most recent performance test demonstrating compliance with the particulate matter emission...
12 CFR 563e.28 - Assigned ratings.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Assigned ratings. 563e.28 Section 563e.28 Banks... for Assessing Performance § 563e.28 Assigned ratings. (a) Ratings in general. Subject to paragraphs (b... performance under the lending, investment and service tests, the community development test, the small savings...
Bröder, Arndt; Malejka, Simone
2017-07-01
The experimental manipulation of response biases in recognition-memory tests is an important means for testing recognition models and for estimating their parameters. The textbook manipulations for binary-response formats either vary the payoff scheme or the base rate of targets in the recognition test, with the latter being the more frequently applied procedure. However, some published studies reverted to implying different base rates by instruction rather than actually changing them. Aside from unnecessarily deceiving participants, this procedure may lead to cognitive conflicts that prompt response strategies unknown to the experimenter. To test our objection, implied base rates were compared to actual base rates in a recognition experiment followed by a post-experimental interview to assess participants' response strategies. The behavioural data show that recognition-memory performance was estimated to be lower in the implied base-rate condition. The interview data demonstrate that participants used various second-order response strategies that jeopardise the interpretability of the recognition data. We thus advice researchers against substituting actual base rates with implied base rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
KRUGER AA; MATLACK KS; GONG W
2011-12-29
This report documents melter and off-gas performance results obtained on the DM1200 HLW Pilot Melter during processing of AZ-101 HLW simulants. The tests reported herein are a subset of six tests from a larger series of tests described in the Test Plan for the work; results from the other tests have been reported separately. The solids contents of the melter feeds were based on the WTP baseline value for the solids content of the feeds from pretreatment which changed during these tests from 20% to 15% undissolved solids resulting in tests conducted at two feed solids contents. Based on themore » results of earlier tests with single outlet 'J' bubblers, initial tests were performed with a total bubbling rate of 651 pm. The first set of tests (Tests 1A-1E) addressed the effects of skewing this total air flow rate back and forth between the two installed bubblers in comparison to a fixed equal division of flow between them. The second set of tests (2A-2D) addressed the effects of bubbler depth. Subsequently, as the location, type and number of bubbling outlets were varied, the optimum bubbling rate for each was determined. A third (3A-3C) and fourth (8A-8C) set of tests evaluated the effects of alternative bubbler designs with two gas outlets per bubbler instead of one by placing four bubblers in positions simulating multiple-outlet bubblers. Data from the simulated multiple outlet bubblers were used to design bubblers with two outlets for an additional set of tests (9A-9C). Test 9 was also used to determine the effect of small sugar additions to the feed on ruthenium volatility. Another set of tests (10A-10D) evaluated the effects on production rate of spiking the feed with chloride and sulfate. Variables held constant to the extent possible included melt temperature, plenum temperature, cold cap coverage, the waste simulant composition, and the target glass composition. The feed rate was increased to the point that a constant, essentially complete, cold cap was achieved, which was used as an indicator of a maximized feed rate for each test. The first day of each test was used to build the cold cap and decrease the plenum temperature. The remainder of each test was split into two- to six-day segments, each with a different bubbling rate, bubbler orientation, or feed concentration of chloride and sulfur.« less
Test Plan for SSR Antenna Rotation Rate Stabilization
DOT National Transportation Integrated Search
1981-10-01
A comprehensive test plan is presented to evaluate the impact of wind and ice loading on the rotation rate stability of a Secondary Surveillance Radar (SSR) antenna used for air traffic control surveillance. Antenna rotation rate variations may intro...
Special Tests for Monitoring Fetal Health
... a nonstress test? The nonstress test measures the fetal heart rate in response to fetal movement over time. The ... A belt with a sensor that measures the fetal heart rate is placed around your abdomen. The fetal heart ...
Failure of introduction of food allergens after negative oral food challenge tests in children.
van der Valk, J P M; Gerth van Wijk, R; Vergouwe, Y; de Jong, N W
2015-08-01
One of the purposes to perform an oral food challenge (FC) test is to avoid unnecessary elimination of food allergens. In case of a negative FC test result, the food can be introduced. It is, however, unknown if patients act according to the outcome of the test. This study evaluates the rate of introduction of peanut, hazelnut, cow's milk or hen's egg allergens after a negative FC test. We investigated the introduction rate of children (0-18 years) with a negative FC test visiting the Department of Allergology, Erasmus Medical Centre Rotterdam from 2008 till 2013 and the factors that influence the rate of introduction. Patients were asked to complete a comprehensive questionnaire about their FC test. In total, 157 (38% girls, mean age during challenge 6.9 years) participated in the study. Of these FC tests, 104 (56%) were followed by a successful introduction, 30 (16%) by a partly introduction (traces or processed foods) and 52 (28%) by a failed introduction. Peanut and hazelnut showed a statistically significant lower successful introduction rate. Age, gender, symptoms during FC test, dietary advice and time period to introduction significantly influenced the rate of introduction. One fourth of the children with failure of introducing foods experienced symptoms during the introduction. More than one quarter of all children with a negative FC test result did not introduce the food. The FC test in its current form does not achieve its objective for this group of children.
Physiologic and anti-G suit performance data from YF-16 flight tests
NASA Technical Reports Server (NTRS)
Gillingham, K. K.; Winter, W. R.
1976-01-01
Biomedical data were collected during high-G portions of 11 YF-16 test flights. Test pilots monitored revealed increased respiratory rate and volume, decreased tidal volume, and increased heart rate at higher G levels, with one pilot exhibiting various cardiac arrhythmias. Anti-G suit inflation and pressurization lags varied inversely with G-onset rate, and suit pressurization slope was near the design value.
[*C]octanoic acid breath test to measure gastric emptying rate of solids.
Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G
1994-12-01
We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.
Creep Strain and Strain Rate Response of 2219 Al Alloy at High Stress Levels
NASA Technical Reports Server (NTRS)
Taminger, Karen M. B.; Wagner, John A.; Lisagor, W. Barry
1998-01-01
As a result of high localized plastic deformation experienced during proof testing in an International Space Station connecting module, a study was undertaken to determine the deformation response of a 2219-T851 roll forging. After prestraining 2219-T851 Al specimens to simulate strains observed during the proof testing, creep tests were conducted in the temperature range from ambient temperature to 107 C (225 F) at stress levels approaching the ultimate tensile strength of 2219-T851 Al. Strain-time histories and strain rate responses were examined. The strain rate response was extremely high initially, but decayed rapidly, spanning as much as five orders of magnitude during primary creep. Select specimens were subjected to incremental step loading and exhibited initial creep rates of similar magnitude for each load step. Although the creep rates decreased quickly at all loads, the creep rates dropped faster and reached lower strain rate levels for lower applied loads. The initial creep rate and creep rate decay associated with primary creep were similar for specimens with and without prestrain; however, prestraining (strain hardening) the specimens, as in the aforementioned proof test, resulted in significantly longer creep life.
Baroreflex modulation of muscle sympathetic nerve activity during cold pressor test in humans
NASA Technical Reports Server (NTRS)
Cui, Jian; Wilson, Thad E.; Crandall, Craig G.
2002-01-01
The purpose of this project was to test the hypothesis that baroreceptor modulation of muscle sympathetic nerve activity (MSNA) and heart rate is altered during the cold pressor test. Ten subjects were exposed to a cold pressor test by immersing a hand in ice water for 3 min while arterial blood pressure, heart rate, and MSNA were recorded. During the second and third minute of the cold pressor test, blood pressure was lowered and then raised by intravenous bolus infusions of sodium nitroprusside and phenylephrine HCl, respectively. The slope of the relationship between MSNA and diastolic blood pressure was more negative (P < 0.005) during the cold pressor test (-244.9 +/- 26.3 units x beat(-1) x mmHg(-1)) when compared with control conditions (-138.8 +/- 18.6 units x beat(-1) x mmHg(-1)), whereas no significant change in the slope of the relationship between heart rate and systolic blood pressure was observed. These data suggest that baroreceptors remain capable of modulating MSNA and heart rate during a cold pressor test; however, the sensitivity of baroreflex modulation of MSNA is elevated without altering the sensitivity of baroreflex control of heart rate.
CO2 Washout Testing of the REI and EM-ACES Space Suits
NASA Technical Reports Server (NTRS)
Mitchell, Kathryn C.; Norcross, Jason
2012-01-01
When a space suit is used during ground testing, adequate carbon dioxide (CO2) washout must be provided for the suited subject. Symptoms of acute CO2 exposure depend on partial pressure of CO2 (ppCO2), metabolic rate of the subject, and other factors. This test was done to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) for a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of about 500 to 3000 BTU/hr. Supply airflow was varied between 6, 5, and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored in real time by gas analyzers with sampling tubes connected to the mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the suit air outlet. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was affected mainly by the metabolic rate of the subject: increased metabolic rate significantly (P < 0.05) increased inspired ppCO2. Decreased air flow caused small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates . 2000 BTU/hr. CO2 washout values of the EM-ACES were slightly but not significantly better than those of the REI suit. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology, and results as well as implications for future ground testing in the REI-suit and EM-ACES.
Kirsch, L E; Nguyen, L; Moeckly, C S; Gerth, R
1997-01-01
Helium leak rate measurements were quantitatively correlated to the probability of microbial ingress for rubber-stoppered glass vials subjected to immersion challenge. Standard 10-mL tubing glass vials were modified by inserting micropipettes of various sizes (0.1 to 10 microns nominal diameter) into a side wall hole and securing them with epoxy. Butyl rubber closures and aluminum crimps were used to seal the vials. The test units were sealed in a helium-filled glove bag, then the absolute helium leak rates were determined. The test units were disassembled, filled with media, resealed, and autoclaved. The test units were thermally treated to eliminate airlocks within the micropipette lumen and establish a liquid path between microbial challenge media and the test units' contents. Microbial challenge was performed by immersing the test units in a 35 degrees C bath containing magnesium ion and 8 to 10 logs of viable P. diminuta and E. coli for 24 hours. The test units were then incubated at 35 degrees C for an additional 13 days. Microbial ingress was detected by turbidity and plating on blood agar. The elimination of airlocks was confirmed by the presence of magnesium ions in the vial contents by atomic absorption spectrometry. A total of 288 vials were subjected to microbial challenge testing. Those test units whose contents failed to show detectable magnesium ions were eliminated from further analysis. At large leak rates, the probability of microbial ingress approached 100% and at very low leak rates microbial ingress rates were 0%. A dramatic increase in microbial failure occurred in the leak rate region 10(-4.5) to 10(-3) std cc/sec, which roughly corresponded to leak diameters ranging from 0.4 to 2 microns. Below a leak rate of 10(-4.5) std cc/sec the microbial failure rate was < 10%. The critical leak rate in our studies, i.e. the value below which microbial ingress cannot occur because the leak is too small, was observed to be between 10(-5) and 10(-5.8) std cc/sec, which corresponds to an approximate leak diameter of 0.2-0.3 micron.
Pneumatic testing in 45-degree-inclined boreholes in ash-flow tuff near Superior, Arizona
LeCain, G.D.
1995-01-01
Matrix permeability values determined by single-hole pneumatic testing in nonfractured ash-flow tuff ranged from 5.1 to 20.3 * 1046 m2 (meters squared), depending on the gas-injection rate and analysis method used. Results from the single-hole tests showed several significant correlations between permeability and injection rate and between permeability and test order. Fracture permeability values determined by cross-hole pneumatic testing in fractured ash-flow tuff ranged from 0.81 to 3.49 * 1044 m2, depending on injection rate and analysis method used. Results from the cross-hole tests monitor intervals showed no significant correlation between permeability and injection rate; however, results from the injection interval showed a significant correlation between injection rate and permeability. Porosity estimates from the 'cross-hole testing range from 0.8 to 2.0 percent. The maximum temperature change associated with the pneumatic testing was 1.2'(2 measured in the injection interval during cross-hole testing. The maximum temperature change in the guard and monitor intervals was O.Ip C. The maximum error introduced into the permeability values due to temperature fluctuations is approximately 4 percent. Data from temperature monitoring in the borehole indicated a positive correlation between the temperature decrease in the injection interval during recovery testing and the gas-injection rate. The thermocouple psychrometers indicated that water vapor was condensing in the boreholes during testing. The psychrometers in the guard and monitor intervals detected the drier injected gas as an increase in the dry bulb reading. The relative humidity in the test intervals was always higher than the upper measurement limit of the psychrometers. Although the installation of the packer system may have altered the water balance of the borehole, the gas-injection testing resulted in minimal or no changes in the borehole relative humidity.
Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.
Stern, C H; Jaasma, D R; Champion, M R
1993-03-01
A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.
Shah, Ajit; Sava-Shah, Shrenik; Wijeratne, Chanaka; Draper, Brian
2016-06-01
It has been hypothesised that the very nature of the game predisposes elite cricketers to higher rates of suicide. We aim to estimate the suicide rate of male Test cricketers and to determine the reasons for suicide. The suicide rate in male Test cricketers was determined. A psychological autopsy was conducted using published biographical data. Twenty suicides amongst 2794 male Test cricketers from 1877 to 2014 yielded a suicide rate of 715.4 per 100,000 for that period. Health, financial and relationship issues were prominent; depression and alcohol misuse were common. Most suicides in Test cricketers occurred post-retirement in mid to late life with similar correlates to those found in the general male population. The idiosyncrasies of cricket are unlikely to contribute to suicide; however, the post-retirement welfare of Test cricketers should remain a focus of concern and the greater supports available to contemporary Test cricketers needs to extend beyond retirement. © The Royal Australian and New Zealand College of Psychiatrists 2016.
Verification of International Space Station Component Leak Rates by Helium Accumulation Method
NASA Technical Reports Server (NTRS)
Underwood, Steve D.; Smith, Sherry L.
2003-01-01
Discovery of leakage on several International Space Station U.S. Laboratory Module ammonia system quick disconnects (QDs) led to the need for a process to quantify total leakage without removing the QDs from the system. An innovative solution was proposed allowing quantitative leak rate measurement at ambient external pressure without QD removal. The method utilizes a helium mass spectrometer configured in the detector probe mode to determine helium leak rates inside a containment hood installed on the test component. The method was validated through extensive developmental testing. Test results showed the method was viable, accurate and repeatable for a wide range of leak rates. The accumulation method has been accepted by NASA and is currently being used by Boeing Huntsville, Boeing Kennedy Space Center and Boeing Johnson Space Center to test welds and valves and will be used by Alenia to test the Cupola. The method has been used in place of more expensive vacuum chamber testing which requires removing the test component from the system.
Technology diffusion and diagnostic testing for prostate cancer
Schroeck, Florian R.; Kaufman, Samuel R.; Jacobs, Bruce L.; Skolarus, Ted A.; Miller, David C.; Weizer, Alon Z.; Montgomery, Jeffrey S.; Wei, John T.; Shahinian, Vahakn B.; Hollenbeck, Brent K.
2013-01-01
Purpose While the dissemination of robotic prostatectomy and intensity-modulated radiotherapy (IMRT) may fuel increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with receipt of prostate specific antigen (PSA) testing and prostate biopsy. Methods In this retrospective cohort study, we included 117,857 men age 66 and older from the 5% sample of Medicare beneficiaries living in the Surveillance Epidemiology and End Results (SEER) areas from 2003 – 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or IMRT per population in a healthcare market (i.e., hospital referral region). We assessed the association of technology penetration with rates of PSA testing and prostate biopsy with generalized estimating equations. Results High technology penetration was associated with increased rates of PSA testing (442 versus 425 per 1,000 person-years, p<0.01) and similar rates of prostate biopsy (10.1 versus 9.9 per 1,000 person-years, p=0.69). The impact of technology penetration on PSA testing and prostate biopsy was much smaller than the effect of age, race, and comorbidity (e.g., PSA testing rate per 1,000 person-years: 485 versus 373 for men with only one versus 3+ co-morbid conditions, p<0.01). Conclusions Increased technology penetration was associated with slightly higher rates of PSA testing and no change in prostate biopsy rates. Collectively, our findings temper concerns that adoption of new technology accelerates diagnostic testing for prostate cancer. PMID:23669564
Expanded HIV Testing in the US Department of Veterans Affairs, 2009–2011
Halloran, CNS, James; Pedati, Caitlin; Dursa, Erin K.; Durfee, Janet; Martinello, Richard; Davey, Victoria; Ross, David
2013-01-01
Objectives. We measured HIV testing and seropositivity among veterans in Veterans Affairs (VA) care for calendar years 2009 through 2011 and analyzed 2011 results by patient demographics. Methods. We performed a repeated-measures cross-sectional study using standardized electronic data extraction from the VA electronic health records for all veterans with at least 1 outpatient visit during 2009 through 2011. We analyzed testing rates and seropositivity by demographic characteristics for 2011. Results. Of veterans with an outpatient visit, 20.0% had an HIV test in 2011, compared with 9.2% in 2009. Documented HIV testing rates were highest in women and Blacks. Of confirmed positive test results, 67.0% were in outpatients older than 50 years. Seropositivity was highest among men aged 30 to 49 years, women aged 50 to 69 years, and Black outpatients of both genders. Implementation of an electronic clinical reminder was associated with higher testing rates. Conclusions. The significant effect of an electronic clinical reminder suggests that such decision support tools can substantially increase testing rates. The frequency of positive test results in older individuals suggests the need for additional work to define optimum approaches to HIV testing in this population. PMID:24134344
105-KE Isolation Barrier Leak Rate Acceptance Test Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCracken, K.J.
1995-06-14
This Acceptance Test Report (ATR) contains the completed and signed Acceptance Procedure (ATP) for the 105-KE Isolations Barrier Leak Rate Test. The Test Engineer`s log, the completed sections of the ATP in the Appendix for Repeat Testing (Appendix K), the approved WHC J-7s (Appendix H), the data logger files (Appendices T and U), and the post test calibration checks (Appendix V) are included.
Lin, Karl K; Rahman, Mohammad A
2018-05-21
Interest has been expressed in using a joint test procedure that requires that the results of both a trend test and a pairwise comparison test between the control and the high groups be statistically significant simultaneously at the levels of significance recommended in the FDA 2001 draft guidance for industry document for the separate tests in order for the drug effect on the development of an individual tumor type to be considered as statistically significant. Results of our simulation studies show that there is a serious consequence of large inflations of the false negative rate through large decreases of false positive rate in the use of the above joint test procedure in the final interpretation of the carcinogenicity potential of a new drug if the levels of significance recommended for separate tests are used. The inflation can be as high as 204.5% of the false negative rate when the trend test alone is required to test if the effect is statistically significant. To correct the problem, new sets of levels of significance have also been developed for those who want to use the joint test in reviews of carcinogenicity studies.
In vitro dynamic solubility test: influence of various parameters.
Thélohan, S; de Meringo, A
1994-01-01
This article discusses the dissolution of mineral fibers in simulated physiological fluids (SPF), and the parameters that affect the solubility measurement in a dynamic test where an SPF runs through a cell containing fibers (Scholze and Conradt test). Solutions simulate either the extracellular fluid (pH 7.6) or the intracellular fluid (pH 4.5). The fibers have various chemical compositions and are either continuously drawn or processed as wool. The fiber solubility is determined by the amount of SiO2 (and occasionally other ions) released in the solution. Results are stated as percentage of the initial silica content released or as dissolution rate v in nm/day. The reproducibility of the test is higher with the less soluble fibers (10% solubility), than with highly soluble fibers (20% solubility). The influence of test parameters, including SPF, test duration, and surface area/volume (SA/V), has been studied. The pH and the inorganic buffer salts have a major influence: industrial glasswool composition is soluble at pH 7.6 but not at pH 4.5. The opposite is true for rock- (basalt) wool composition. For slightly soluble fibers, the dissolution rate v remains constant with time, whereas for highly soluble fibers, the dissolution rate decreases rapidly. The dissolution rates believed to occur are v1, initial dissolution rate, and v2, dissolution rate of the residual fibers. The SA of fibers varies with the mass of the fibers tested, or with the fiber diameter at equal mass. Volume, V, is the chosen flow rate. An increase in the SA/V ratio leads to a decrease in the dissolution rate.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7882964
In vitro dynamic solubility test: influence of various parameters.
Thélohan, S; de Meringo, A
1994-10-01
This article discusses the dissolution of mineral fibers in simulated physiological fluids (SPF), and the parameters that affect the solubility measurement in a dynamic test where an SPF runs through a cell containing fibers (Scholze and Conradt test). Solutions simulate either the extracellular fluid (pH 7.6) or the intracellular fluid (pH 4.5). The fibers have various chemical compositions and are either continuously drawn or processed as wool. The fiber solubility is determined by the amount of SiO2 (and occasionally other ions) released in the solution. Results are stated as percentage of the initial silica content released or as dissolution rate v in nm/day. The reproducibility of the test is higher with the less soluble fibers (10% solubility), than with highly soluble fibers (20% solubility). The influence of test parameters, including SPF, test duration, and surface area/volume (SA/V), has been studied. The pH and the inorganic buffer salts have a major influence: industrial glasswool composition is soluble at pH 7.6 but not at pH 4.5. The opposite is true for rock- (basalt) wool composition. For slightly soluble fibers, the dissolution rate v remains constant with time, whereas for highly soluble fibers, the dissolution rate decreases rapidly. The dissolution rates believed to occur are v1, initial dissolution rate, and v2, dissolution rate of the residual fibers. The SA of fibers varies with the mass of the fibers tested, or with the fiber diameter at equal mass. Volume, V, is the chosen flow rate. An increase in the SA/V ratio leads to a decrease in the dissolution rate.(ABSTRACT TRUNCATED AT 250 WORDS)
Smith, R.L.; Garabedian, S.P.; Brooks, M.H.
1996-01-01
The transport of many solutes in groundwater is dependent upon the relative rates of physical flow and microbial metabolism. Quantifying rates of microbial processes under subsurface conditions is difficult and is most commonly approximated using laboratory studies with aquifer materials. In this study, we measured in situ rates of denitrification in a nitrate- contaminated aquifer using small-scale, natural-gradient tracer tests and compared the results with rates obtained from laboratory incubations with aquifer core material. Activity was measured using the acetylene block technique. For the tracer tests, co-injection of acetylene and bromide into the aquifer produced a 30 ??M increase in nitrous oxide after 10 m of transport (23-30 days). An advection-dispersion transport model was modified to include an acetylene-dependent nitrous oxide production term and used to simulate the tracer breakthrough curves. The model required a 4-day lag period and a relatively low sensitivity to acetylene to match the narrow nitrous oxide breakthrough curves. Estimates of in situ denitrification rates were 0.60 and 1.51 nmol of N2O produced cm-3 aquifer day-1 for two successive tests. Aquifer core material collected from the tracer test site and incubated as mixed slurries in flasks and as intact cores yielded rates that were 1.2-26 times higher than the tracer test rate estimates. Results with the coring-dependent techniques were variable and subject to the small- scale heterogeneity within the aquifer, while the tracer tests integrated the heterogeneity along a flow path, giving a rate estimate that is more applicable to transport at the scale of the aquifer.
Kneeshaw, T.A.; McGuire, J.T.; Smith, E.W.; Cozzarelli, I.M.
2007-01-01
This paper presents small-scale push-pull tests designed to evaluate the kinetic controls on SO42 - reduction in situ at mixing interfaces between a wetland and aquifer impacted by landfill leachate at the Norman Landfill research site, Norman, OK. Quantifying the rates of redox reactions initiated at interfaces is of great interest because interfaces have been shown to be zones of increased biogeochemical transformations and thus may play an important role in natural attenuation. To mimic the aquifer-wetland interface and evaluate reaction rates, SO42 --rich anaerobic aquifer water (??? 100 mg / L SO42 -) was introduced into SO42 --depleted wetland porewater via push-pull tests. Results showed SO42 - reduction was stimulated by the mixing of these waters and first-order rate coefficients were comparable to those measured in other push-pull studies. However, rate data were complex involving either multiple first-order rate coefficients or a more complex rate order. In addition, a lag phase was observed prior to SO42 - reduction that persisted until the mixing interface between test solution and native water was recovered, irrespective of temporal and spatial constraints. The lag phase was not eliminated by the addition of electron donor (acetate) to the injected test solution. Subsequent push-pull tests designed to elucidate the nature of the lag phase support the importance of the mixing interface in controlling terminal electron accepting processes. These data suggest redox reactions may occur rapidly at the mixing interface between injected and native waters but not in the injected bulk water mass. Under these circumstances, push-pull test data should be evaluated to ensure the apparent rate is actually a function of time and that complexities in rate data be considered. ?? 2007 Elsevier Ltd. All rights reserved.
Parikh, Mili; Hynan, Linda S; Weiner, Myron F; Lacritz, Laura; Ringe, Wendy; Cullum, C Munro
2014-01-01
Alzheimer disease (AD) characteristically begins with episodic memory impairment followed by other cognitive deficits; however, the course of illness varies, with substantial differences in the rate of cognitive decline. For research and clinical purposes it would be useful to distinguish between persons who will progress slowly from persons who will progress at an average or faster rate. Our objective was to use neurocognitive performance features and disease-specific and health information to determine a predictive model for the rate of cognitive decline in participants with mild AD. We reviewed the records of a series of 96 consecutive participants with mild AD from 1995 to 2011 who had been administered selected neurocognitive tests and clinical measures. Based on Clinical Dementia Rating (CDR) of functional and cognitive decline over 2 years, participants were classified as Faster (n = 45) or Slower (n = 51) Progressors. Stepwise logistic regression analyses using neurocognitive performance features, disease-specific, health, and demographic variables were performed. Neuropsychological scores that distinguished Faster from Slower Progressors included Trail Making Test - A, Digit Symbol, and California Verbal Learning Test (CVLT) Total Learned and Primacy Recall. No disease-specific, health, or demographic variable predicted rate of progression; however, history of heart disease showed a trend. Among the neuropsychological variables, Trail Making Test - A best distinguished Faster from Slower Progressors, with an overall accuracy of 68%. In an omnibus model including neuropsychological, disease-specific, health, and demographic variables, only Trail Making Test - A distinguished between groups. Several neuropsychological performance features were associated with the rate of cognitive decline in mild AD, with baseline Trail Making Test - A performance best separating those who declined at an average or faster rate from those who showed slower progression.
Hommel, Gerhard; Bretz, Frank; Maurer, Willi
2011-07-01
Global tests and multiple test procedures are often based on ordered p values. Such procedures are available for arbitrary dependence structures as well as for specific dependence assumptions of the test statistics. Most of these procedures have been considered as global tests. Multiple test procedures can be obtained by applying the closure principle in order to control the familywise error rate, or by using the false discovery rate as a criterion for type I error rate control. We provide an overview and present examples showing the importance of these procedures in medical research. Finally, we discuss modifications when different weights for the hypotheses of interest are chosen.
Investigation of creep by use of closed loop servo-hydraulic test system
NASA Technical Reports Server (NTRS)
Wu, H. C.; Yao, J. C.
1981-01-01
Creep tests were conducted by means of a closed loop servo-controlled materials test system. These tests are different from the conventional creep tests in that the strain history prior to creep may be carefully monitored. Tests were performed for aluminum alloy 6061-0 at 150 C and monitored by a PDP 11/04 minicomputer at a preset constant plastic-strain rate prehistory. The results show that the plastic-strain rate prior to creep plays a significant role in creep behavior. The endochronic theory of viscoplasticity was applied to describe the observed creep curves. The concepts of intrinsic time and strain rate sensitivity function are employed and modified according to the present observation.
HIV Testing and Diagnosis Rates in Kiev, Ukraine: April 2013-March 2014.
Simmons, Ruth; Malyuta, Ruslan; Chentsova, Nelli; Medoeva, Antonia; Kruglov, Yuri; Yurchenko, Alexander; Copas, Andrew; Porter, Kholoud
2015-01-01
Data from Ukraine on risk factors for HIV acquisition are limited. We describe the characteristics of individuals testing for HIV in the main testing centres of the Ukrainian capital Kiev, including HIV risk factors, testing rates, and positivity rates. As part of a larger study to estimate HIV incidence within Kiev City, we included questions on possible risk factors for HIV acquisition and testing history to existing systems in 4 infectious disease clinics. Data were provided by the person requesting an HIV test using a handheld electronic tablet. All persons (≥16 yrs) presenting for an HIV test April 2013-March 2014 were included. Rates per 100,000 were calculated using region-specific denominators for Kiev. During the study period 6370 individuals tested for HIV, equivalent to a testing rate of 293.2 per 100,000. Of these, 467 (7.8%) were HIV-positive, with the highest proportion positive among 31-35 year olds (11.2%), males (9.4%), people who inject drugs (PWID) (17.9%) and men who have sex with men (MSM) (24.1%). Using published population size estimates of MSM, diagnosis rates for MSM ranged from 490.6 to 1548.3/100,000. A higher proportion of heterosexual women compared to heterosexual men reported contact with PWID, (16% vs. 4.7%) suggesting a bridging in risk between PWID and their sexual partners. Collection of HIV risk factor information in Kiev, essential for the purposes of developing effective HIV prevention and response tools, is feasible. The high percentage of MSM among those testing positive for HIV, may indicate a significant level of undisclosed sex between men in national figures.
Preloading To Accelerate Slow-Crack-Growth Testing
NASA Technical Reports Server (NTRS)
Gyekenyesi, John P.; Choi, Sung R.; Pawlik, Ralph J.
2004-01-01
An accelerated-testing methodology has been developed for measuring the slow-crack-growth (SCG) behavior of brittle materials. Like the prior methodology, the accelerated-testing methodology involves dynamic fatigue ( constant stress-rate) testing, in which a load or a displacement is applied to a specimen at a constant rate. SCG parameters or life prediction parameters needed for designing components made of the same material as that of the specimen are calculated from the relationship between (1) the strength of the material as measured in the test and (2) the applied stress rate used in the test. Despite its simplicity and convenience, dynamic fatigue testing as practiced heretofore has one major drawback: it is extremely time-consuming, especially at low stress rates. The present accelerated methodology reduces the time needed to test a specimen at a given rate of applied load, stress, or displacement. Instead of starting the test from zero applied load or displacement as in the prior methodology, one preloads the specimen and increases the applied load at the specified rate (see Figure 1). One might expect the preload to alter the results of the test and indeed it does, but fortunately, it is possible to account for the effect of the preload in interpreting the results. The accounting is done by calculating the normalized strength (defined as the strength in the presence of preload the strength in the absence of preload) as a function of (1) the preloading factor (defined as the preload stress the strength in the absence of preload) and (2) a SCG parameter, denoted n, that is used in a power-law crack-speed formulation. Figure 2 presents numerical results from this theoretical calculation.
HIV Testing and Diagnosis Rates in Kiev, Ukraine: April 2013 - March 2014
Simmons, Ruth; Malyuta, Ruslan; Medoeva, Antonia; Kruglov, Yuri; Yurchenko, Alexander; Copas, Andrew; Porter, Kholoud
2015-01-01
Objective Data from Ukraine on risk factors for HIV acquisition are limited. We describe the characteristics of individuals testing for HIV in the main testing centres of the Ukrainian capital Kiev, including HIV risk factors, testing rates, and positivity rates. Methods As part of a larger study to estimate HIV incidence within Kiev City, we included questions on possible risk factors for HIV acquisition and testing history to existing systems in 4 infectious disease clinics. Data were provided by the person requesting an HIV test using a handheld electronic tablet. All persons (≥16yrs) presenting for an HIV test April 2013–March 2014 were included. Rates per 100,000 were calculated using region-specific denominators for Kiev. Results During the study period 6370 individuals tested for HIV, equivalent to a testing rate of 293.2 per 100,000. Of these, 467 (7.8%) were HIV-positive, with the highest proportion positive among 31–35 year olds (11.2%), males (9.4%), people who inject drugs (PWID) (17.9%) and men who have sex with men (MSM) (24.1%). Using published population size estimates of MSM, diagnosis rates for MSM ranged from 490.6to 1548.3/100,000. A higher proportion of heterosexual women compared to heterosexual men reported contact with PWID, (16% vs. 4.7%) suggesting a bridging in risk between PWID and their sexual partners. Conclusion Collection of HIV risk factor information in Kiev, essential for the purposes of developing effective HIV prevention and response tools, is feasible. The high percentage of MSM among those testing positive for HIV, may indicate a significant level of undisclosed sex between men in national figures. PMID:26322977
Spacecraft Parachute Recovery System Testing from a Failure Rate Perspective
NASA Technical Reports Server (NTRS)
Stewart, Christine E.
2013-01-01
Spacecraft parachute recovery systems, especially those with a parachute cluster, require testing to identify and reduce failures. This is especially important when the spacecraft in question is human-rated. Due to the recent effort to make spaceflight affordable, the importance of determining a minimum requirement for testing has increased. The number of tests required to achieve a mature design, with a relatively constant failure rate, can be estimated from a review of previous complex spacecraft recovery systems. Examination of the Apollo parachute testing and the Shuttle Solid Rocket Booster recovery chute system operation will clarify at which point in those programs the system reached maturity. This examination will also clarify the risks inherent in not performing a sufficient number of tests prior to operation with humans on-board. When looking at complex parachute systems used in spaceflight landing systems, a pattern begins to emerge regarding the need for a minimum amount of testing required to wring out the failure modes and reduce the failure rate of the parachute system to an acceptable level for human spaceflight. Not only a sufficient number of system level testing, but also the ability to update the design as failure modes are found is required to drive the failure rate of the system down to an acceptable level. In addition, sufficient data and images are necessary to identify incipient failure modes or to identify failure causes when a system failure occurs. In order to demonstrate the need for sufficient system level testing prior to an acceptable failure rate, the Apollo Earth Landing System (ELS) test program and the Shuttle Solid Rocket Booster Recovery System failure history will be examined, as well as some experiences in the Orion Capsule Parachute Assembly System will be noted.
Effects of air ventilation during stationary exercise testing.
Van Schuylenbergh, R; Vanden Eynde, B; Hespel, P
2004-07-01
The impact of air ventilation on performance and physiological responses during stationary exercise in the laboratory was studied. Fourteen well-trained cyclists performed three exercise tests on a cycle ergometer, each separated by a 1-week interval. The first test was a graded test to determine the power output corresponding with the 4-mmol l(-1) lactate level. Tests 2 and 3 were 30-min constant-load tests at a power output corresponding with this 4-mmol l(-1) lactate threshold. One constant-load test was performed in the absence (NAV), whilst the other was performed in the presence (AV) of air ventilation (3 m s(-1)). During the constant-load tests, heart rate, tympanic temperature, blood lactate concentration and oxygen uptake (VO2) were measured at 10-min intervals and at the end of the test. Differences between the two test conditions were evaluated using paired t-tests. During NAV, 12 subjects interrupted the test due to premature exhaustion (exercise duration <30 min), versus only seven in AV ( P<0.05). At the end of the test tympanic temperature was 35.9 (0.2) degrees C in AV and was higher in NAV [36.7 (0.2) degrees C, P<0.05]. Exercise heart rate increased at a faster rate during NAV [+2.2 (0.3) beats min(-1)] than during AV [+1.5 (0.2) beats min(-1), P<0.05]. Blood lactate concentration and VO2 were similar between conditions. Air ventilation is essential to prevent an upward shift in the lactate:heart rate as well as the power output:heart rate relationship during laboratory exercise testing and indoor exercise training.
Miniature bulge test and energy release rate in HIPed aluminum/aluminum interfacial fracture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, C.; Lovato, M. L.; Clarke, K. D.
We summarize the development of a technique of using miniature bulge test combined with three-dimensional digital image correlation (3D-DIC) for measuring energy release rate or fracture toughness of bimaterial interface of thin metal foils. Furthermore, the energy release rate associated with the HIPed aluminum/aluminum interfacial delamination is determined experimentally using the proposed technique. Detailed discussions of the schemes of preparing and conducting the bulge test, and computing various quantities required for the determination of the energy release rate are presented.
Miniature bulge test and energy release rate in HIPed aluminum/aluminum interfacial fracture
Liu, C.; Lovato, M. L.; Clarke, K. D.; ...
2017-10-13
We summarize the development of a technique of using miniature bulge test combined with three-dimensional digital image correlation (3D-DIC) for measuring energy release rate or fracture toughness of bimaterial interface of thin metal foils. Furthermore, the energy release rate associated with the HIPed aluminum/aluminum interfacial delamination is determined experimentally using the proposed technique. Detailed discussions of the schemes of preparing and conducting the bulge test, and computing various quantities required for the determination of the energy release rate are presented.
Biofidelity assessment of the 6-year-old ATDs in lateral impact.
Yaek, J L; Li, Y; Lemanski, P J; Begeman, P C; Rouhana, S W; Cavanaugh, J M
2016-07-03
The objective of this study was to assess and compare the current lateral impact biofidelity of the shoulder, thorax, abdomen, and pelvis of the Q6, Q6s, and Hybrid III (HIII) 6-year-old anthropomorphic test devices (ATDs) through lateral impact testing. A series of lateral impact pendulum tests, vertical drop tests, and Wayne State University (WSU) sled tests was performed, based on the procedures detailed in ISO/TR 9790 (1999) and scaling to the 6-year-old using Irwin et al. ( 2002 ). The HIII used in this study was tested with the Ford-designed abdomen described in Rouhana ( 2006 ) and Elhagediab et al. ( 2006 ). The data collected from the 3 different ATDs were filtered using SAE J211 (SAE International 2003 ), aligned using the methodology described by Donnelly and Moorhouse ( 2012 ), and compared for each body region tested (shoulder, thorax, abdomen, and pelvis). The biofidelity performance in lateral impact for the 3 ATDs was assessed against the scaled biofidelity targets published in Irwin et al. ( 2002 ), the abdominal biofidelity target suggested in van Ratingen et al. ( 1997 ), and the biofidelity targets published in Rhule et al. ( 2013 ). Regional and overall biofidelity rankings for each of the 3 ATDs were performed using both the ISO 9790 biofidelity rating system (ISO/TR 9790 1999) and the NHTSA's external biofidelity ranking system (BRS; Rhule et al. 2013 ). All 3 6-year-old ATD's pelvises were rated as least biofidelic of the 4 body regions tested, based on both the ISO and BRS biofidelity rating systems, followed by the shoulder and abdomen, respectively. The thorax of all 3 ATDs was rated as the most biofidelic body region using the aforementioned biofidelity rating systems. The HIII 6-year-old ATD was rated last in overall biofidelity of the 3 tested ATDs, based on both rating systems. The Q6s ATD was rated as having the best overall biofidelity using both rating systems. All 3 ATDs are more biofidelic in the thorax and abdomen than the shoulder and pelvis, with the pelvis being the least biofidelic of all 4 tested body regions. None of the 3 tested 6-year-old ATDs had an overall ranking of 2.0 or less, based on the BRS ranking. Therefore, it is expected that none of the 3 ATDs would mechanically respond like a postmortem human subject (PMHS) in a lateral impact crash test based on this ranking system. With respect to the ISO biofidelity rating, the HIII dummy would be considered unsuitable and the Q-series dummies would be considered marginal for assessing side impact occupant protection.
Soil-test N recommendations augmented with PEST optimized RZWQM simulations
USDA-ARS?s Scientific Manuscript database
Fertilizer application rates based on soil nitrate tests may help reduce N loss to the environment. The late spring nitrate test (LSNT) is one such test and improving our understanding of year-to-year N rate differences may increase its use. It is known that annual plant available soil N is associat...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-03
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2013, through December 31, 2013, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-01
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2012, through December 31, 2012, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... minimum random drug and alcohol testing percentage rates for the period January 1, 2011, through December 31, 2011, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2014, through December 31, 2014, will remain at 25 percent of safety- sensitive employees for random drug testing and 10...
Controlling Item Exposure Conditional on Ability in Computerized Adaptive Testing.
ERIC Educational Resources Information Center
Stocking, Martha L.; Lewis, Charles
1998-01-01
Ensuring item and pool security in a continuous testing environment is explored through a new method of controlling exposure rate of items conditional on ability level in computerized testing. Properties of this conditional control on exposure rate, when used in conjunction with a particular adaptive testing algorithm, are explored using simulated…
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating? 61.405 Section 61.405 Aeronautics and Space... flight instructor certificate with a sport pilot rating you must pass the following tests: (a) Knowledge...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false What tests do I have to take to obtain a flight instructor certificate with a sport pilot rating? 61.405 Section 61.405 Aeronautics and Space... flight instructor certificate with a sport pilot rating you must pass the following tests: (a) Knowledge...
NASA Technical Reports Server (NTRS)
Rodriguez, P. I.; Markovitch, R.
1992-01-01
This report is intended to reveal the apparent relationship of air seal leakage rates between 2 atmospheres (atm) to 1 atm and 1 atm to vacuum conditions. Gas dynamics analysis is provided as well as data summarizing the MSFC test report, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study With Delta Pressure Leak Rate Comparison Test Report'.
Sawe, Hendry R; Mfinanga, Juma A; Ringo, Faith H; Mwafongo, Victor; Reynolds, Teri A; Runyon, Michael S
2016-01-01
Objectives To describe the HIV counselling and testing practices for children presenting to an emergency department (ED) in a low-income country. Setting The ED of a large east African national referral hospital. Participants This retrospective review of all paediatric (<18 years old) ED visits in 2012 enrolled patients who had an HIV test ordered and excluded those without testing. Files were available for 5540/5774 (96%) eligible patients and 1632 (30%) were tested for HIV, median age 1.3 years (IQR 9 months to 4 years), 58% <18 months old and 61% male. Primary and secondary outcome measures The primary outcome measure was documentation of pretest and post-test counselling, or deferral of counselling, for children tested for HIV in the ED. Secondary measures included the overall rate of HIV testing, rate of counselling documented in the inpatient record when deferred in the ED, rate of counselling documented when testing was initiated by the inpatient service, rate of counselling documented by test result (positive vs negative) and the rate of referral to follow-up HIV care among patients testing positive. Results Of 418 patients tested in the ED, counselling, or deferral of counselling, was documented for 70 (17%). When deferred to the ward, subsequent counselling was documented for 15/42 (36%). Counselling was documented in 33% of patients testing positive versus 1.1% patients testing negative (OR 43 (95% CI 23 to 83). Of 199 patients who tested positive and survived to hospital discharge, 76 (38%) were referred for follow-up at the HIV clinic on discharge. Conclusions Physicians documented the provision, or deferral, of counselling for <20% of children tested for HIV in the ED. Counselling was much more likely to be documented when the test result was positive. Less than 40% of those testing positive were referred for follow-up care. PMID:26880672
Live load testing and load rating of five reinforced concrete bridges.
DOT National Transportation Integrated Search
2014-10-01
Five cast-in-place concrete T-beam bridges Eustis #5341, Whitefield #3831, Cambridge #3291, Eddington #5107, : and Albion #2832 were live load tested. Revised load ratings were computed either using test data or detailed : analysis when possi...
Anders, Sven; Pyka, Katharina; Mueller, Tjark; von Streinbuechel, Nicole; Raupach, Tobias
2016-11-01
Student learning outcome is an important dimension of teaching quality in undergraduate medical education. Measuring an increase in knowledge during teaching requires repetitive objective testing which is usually not feasible. As an alternative, student learning outcome can be calculated from student self-ratings. Comparative self-assessment (CSA) gain reflects the performance difference before and after teaching, adjusted for initial knowledge. It has been shown to be a valid proxy measure of actual learning outcome derived from objective tests. However, student self-ratings are prone to a number of confounding factors. In the context of outcome-based evaluation, the wording of self-rating items is crucial to the validity of evaluation results. This randomized trial assessed whether including qualifiers in these statements impacts on student ratings and CSA gain. First-year medical students self-rated their initial (then-test) and final (post-test) knowledge for lectures in anatomy, biochemistry and legal medicine, respectively, and 659 questionnaires were retrieved. Six-point scales were used for self-ratings with 1 being the most positive option. Qualifier use did not affect then-test ratings but was associated with slightly less favorable post-test ratings. Consecutively, mean CSA gain was smaller for items containing qualifiers than for items lacking qualifiers (50.6±15.0% vs. 56.3±14.6%, p=0.079). The effect was more pronounced (Cohen's d=0.82) for items related to anatomy. In order to increase fairness of outcome-based evaluation and increase the comparability of CSA gain data across subjects, medical educators should agree on a consistent approach (qualifiers for all items or no qualifiers at all) when drafting self-rating statements for outcome-based evaluation. Copyright © 2016 Elsevier GmbH. All rights reserved.
McGovern, Mark E; Herbst, Kobus; Tanser, Frank; Mutevedzi, Tinofa; Canning, David; Gareta, Dickman; Pillay, Deenan; Bärnighausen, Till
2016-01-01
Abstract Background: Despite the importance of HIV testing for controlling the HIV epidemic, testing rates remain low. Efforts to scale up testing coverage and frequency in hard-to-reach and at-risk populations commonly focus on home-based HIV testing. This study evaluates the effect of a gift (a US$5 food voucher for families) on consent rates for home-based HIV testing. Methods: We use data on 18 478 individuals (6 418 men and 12 060 women) who were successfully contacted to participate in the 2009 and 2010 population-based HIV surveillance carried out by the Wellcome Trust's Africa Health Research Institute in rural KwaZulu-Natal, South Africa. Of 18 478 potential participants contacted in both years, 35% (6 518) consented to test in 2009, and 41% (7 533) consented to test in 2010. Our quasi-experimental difference-in-differences approach controls for unobserved confounding in estimating the causal effect of the intervention on HIV-testing consent rates. Results: Allocation of the gift to a family in 2010 increased the probability of family members consenting to test in the same year by 25 percentage points [95% confidence interval (CI) 21–30 percentage points; P < 0.001]. The intervention effect persisted, slightly attenuated, in the year following the intervention (2011). Conclusions: In HIV hyperendemic settings, a gift can be highly effective at increasing consent rates for home-based HIV testing. Given the importance of HIV testing for treatment uptake and individual health, as well as for HIV treatment-as-prevention strategies and for monitoring the population impact of the HIV response, gifts should be considered as a supportive intervention for HIV-testing initiatives where consent rates have been low. PMID:27940483
LM193 Dual Differential Comparator Total Ionizing Dose Test Report
NASA Technical Reports Server (NTRS)
Topper, Alyson; Forney, James; Campola, Michael
2017-01-01
The purpose of this test was to characterize the flight lot of Texas Instruments' LM193 (flight part number is 5962-9452601Q2A) for total dose response. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) was determined.
Standardized Testing Practices: Effect on Graduation and NCLEX® Pass Rates.
Randolph, Pamela K
The use standardized testing in pre-licensure nursing programs has been accompanied by conflicting reports of effective practices. The purpose of this project was to describe standardized testing practices in one states' nursing programs and discover if the use of a cut score or oversight of remediation had any effect on (a) first time NCLEX® pass rates, (b) on-time graduation (OTG) or (c) the combination of (a) and (b). Administrators of 38 nursing programs in one Southwest state were sent surveys; surveys were returned by 34 programs (89%). Survey responses were compared to each program's NCLEX pass rate and on-time graduation rate; t-tests were conducted for significant differences associated with a required minimum score (cut score) and oversight of remediation. There were no significant differences in NCLEX pass or on-time graduation rates related to establishment of a cut score. There was a significant difference when the NCLEX pass rate and on-time graduation rate were combined (Outcome Index "OI") with significantly higher program outcomes (P=.02.) for programs without cut-scores. There were no differences associated with faculty oversight of remediation. The results of this study do not support establishment of a cut-score when implementing a standardized testing. Copyright © 2016. Published by Elsevier Inc.
Propagation mode of Portevin-Le Chatelier plastic instabilities in an aluminium-magnesium alloy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeghloul, A.; Mliha-Touati, M.; Bakir, S.
1996-11-01
The Portevin-Le Chatelier (PLC) effect is characterized by the appearance of serrations in load (hard tensile machine for constant strain rate tests) or by steps (soft tensile machine for constant stress rate tests) or by steps (soft tensile machine for constant stress rate tests) on the stress-strain curves. It is now widely accepted that the PLC propagative instability stems from the dynamic interaction between diffusing solute atoms and mobile dislocations in the temperature and strain rate ranges where dynamic strain ageing (DSA) takes place. This competition results in a negative strain-rate sensitivity. However, in some alloys, like concentrated solid solutions,more » shearing of precipitates accompanied by their dissolution and subsequent reprecipitation during tensile test may also lead to a negative strain rate sensitivity. In view of the renewed theoretical interest in propagative instabilities, it is important that the experimental features of band propagation be well characterized. In this work the authors present experimental results that are obtained from the investigation of the PLC bands associated with discontinuous yielding. These results show that the band strain, the band velocity and the propagation mode of the bands depend on the stress rate when the test is carried out on a soft tensile machine.« less
CO2 Washout Testing of the REI and EM-ACES Space Suits
NASA Technical Reports Server (NTRS)
Mitchell, Kate; Norcross, Jason
2011-01-01
Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. The objective of this test was to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) across a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice to allow for comparison between tests. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of approximately 500 to 3000 BTU/hr. Supply airflow was varied at 6, 5 and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was primarily affected by the metabolic rate of the subject, with increased metabolic rate resulting in increased inspired ppCO2. Suit flow rate also affected inspired ppCO2, with decreased flow causing small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates greater than or equal to 2000 BTU/hr. Results were consistent between suits, with the EM-ACES demonstrating slightly better CO2 washout than the REI suit, but not statistically significant. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future ground testing in the REI and EM-ACES.
The Effect of the Laboratory Specimen on Fatigue Crack Growth Rate
NASA Technical Reports Server (NTRS)
Forth, S. C.; Johnston, W. M.; Seshadri, B. R.
2006-01-01
Over the past thirty years, laboratory experiments have been devised to develop fatigue crack growth rate data that is representative of the material response. The crack growth rate data generated in the laboratory is then used to predict the safe operating envelope of a structure. The ability to interrelate laboratory data and structural response is called similitude. In essence, a nondimensional term, called the stress intensity factor, was developed that includes the applied stresses, crack size and geometric configuration. The stress intensity factor is then directly related to the rate at which cracks propagate in a material, resulting in the material property of fatigue crack growth response. Standardized specimen configurations and experimental procedures have been developed for laboratory testing to generate crack growth rate data that supports similitude of the stress intensity factor solution. In this paper, the authors present laboratory fatigue crack growth rate test data and finite element analyses that show similitude between standard specimen configurations tested using the constant stress ratio test method is unobtainable.
Electrical, thermal and abusive tests on lithium thionyl chloride cells
NASA Technical Reports Server (NTRS)
Frank, H. A.
1980-01-01
Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.
Electrical, thermal and abusive tests on lithium thionyl chloride cells
NASA Astrophysics Data System (ADS)
Frank, H. A.
1980-04-01
Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.
75 FR 9018 - Pipeline Safety: Random Drug Testing Rate
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-26
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2010-0034] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...
77 FR 2606 - Pipeline Safety: Random Drug Testing Rate
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-18
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2012-0004] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...
Layton, J. Bradley; Kim, Yoonsang; Alexander, G. Caleb; Emery, Sherry L.
2017-01-01
IMPORTANCE Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. OBJECTIVE To investigate associations between televised DTCA and testosterone testing and initiation in the United States. DESIGN, SETTING, AND POPULATION Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009–2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. EXPOSURES Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. MAIN OUTCOMES AND MEASURES (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. RESULTS Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004–1.008), initiation (RR, 1.007; 95% CI, 1.004–1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002–1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09–0.19), 0.05 new initiations (95% CI, 0.03–0.08), and 0.02 initiations without a recent test (95% CI, 0.01–0.03) per 10 000 men for each monthly ad exposure over the entire period. CONCLUSIONS AND RELEVANCE Among US men residing in the 75 designated market areas, regional exposure to televised direct-to-consumer advertising was associated with greater testosterone testing, new initiation, and initiation without recent testing. PMID:28324090
Instrument Pilot: Airplane. Flight Test Guide, Part 61 Revised 1973, AC 61-56.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
This flight test guide is designed to assist the applicant and his instructor in preparing for the flight test for Instrument Pilot Airplane Rating under Part 61 (revised) of Federal Aviation Regulations. It contains information concerning pilot operations, procedures, and maneuvers relevant to the flight test required for the Instrument Rating.…
Griffith, Joseph F; Goldberg, Jeffrey L
2016-03-01
To determine the frequency of optical coherence tomography (OCT) examinations compared with clinical examinations and visual field (VF) tests in patients with 5 types of glaucoma. A retrospective, longitudinal cohort study was conducted of 5154 patients treated between 2003 and 2010 at a single academic medical center. Patients were classified using billing records as having primary open-angle glaucoma, low-tension open-angle glaucoma (NTG), pigmentary open-angle glaucoma, chronic angle-closure glaucoma, or pseudoexfoliation glaucoma. Analysis of variance, χ test, and exact χ test were performed to identify associations between glaucoma type and test frequency. Pigmentary open-angle glaucoma and NTG patients had a higher rate of undergoing at least 2 VFs (94.4%, 94.9%), and chronic angle-closure glaucoma patients had a lower rate of undergoing at least 2 OCTs (25.3%) than all other glaucoma types. NTG patients also had the highest rate of undergoing at least 2 OCTs and at least 2 VFs (36.6%). Overall, the rate of clinical examinations (2.68 examinations/y) exceeded the rates of OCTs (1.39 examinations/y), which exceeded the rate of VF tests (1.24 tests/y). There were no differences in OCT frequency between glaucoma types (0.91 to 1.63 OCTs/y). Within each glaucoma diagnosis, patients had clinical examinations more frequently than OCTs and clinical examinations more frequently than VFs. Primary open-angle glaucoma and pseudoexfoliation glaucoma patients also had OCTs more frequently than VFs. More patients had at least 2 VF tests than at least 2 OCTs (4481 vs. 1679). The relative use of clinical examinations, VF testing, and OCT imaging varies among glaucoma diagnoses.
Technology diffusion and diagnostic testing for prostate cancer.
Schroeck, Florian R; Kaufman, Samuel R; Jacobs, Bruce L; Skolarus, Ted A; Miller, David C; Weizer, Alon Z; Montgomery, Jeffrey S; Wei, John T; Shahinian, Vahakn B; Hollenbeck, Brent K
2013-11-01
While the dissemination of robotic prostatectomy and intensity modulated radiotherapy may fuel the increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with the receipt of prostate specific antigen testing and prostate biopsy. In this retrospective cohort study we included 117,857 men 66 years old or older from the 5% sample of Medicare beneficiaries living in Surveillance, Epidemiology and End Results (SEER) areas from 2003 to 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or intensity modulated radiotherapy per population in a health care market, ie hospital referral region. We assessed the association of technology penetration with the prostate specific antigen testing rate and prostate biopsy using generalized estimating equations. High technology penetration was associated with an increased rate of prostate specific antigen testing (442 vs 425/1,000 person-years, p<0.01) and a similar rate of prostate biopsy (10.1 vs 9.9/1,000 person-years, p=0.69). The impact of technology penetration on prostate specific antigen testing and prostate biopsy was much less than the effect of age, race and comorbidity, eg the prostate specific antigen testing rate per 1,000 person-years was 485 vs 373 for men with only 1 vs 3+ comorbid conditions (p<0.01). Increased technology penetration is associated with a slightly higher rate of prostate specific antigen testing and no change in the prostate biopsy rate. Collectively, our findings temper concerns that adopting new technology accelerates diagnostic testing for prostate cancer. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Gavett, Brandon E
2015-03-01
The base rates of abnormal test scores in cognitively normal samples have been a focus of recent research. The goal of the current study is to illustrate how Bayes' theorem uses these base rates--along with the same base rates in cognitively impaired samples and prevalence rates of cognitive impairment--to yield probability values that are more useful for making judgments about the absence or presence of cognitive impairment. Correlation matrices, means, and standard deviations were obtained from the Wechsler Memory Scale--4th Edition (WMS-IV) Technical and Interpretive Manual and used in Monte Carlo simulations to estimate the base rates of abnormal test scores in the standardization and special groups (mixed clinical) samples. Bayes' theorem was applied to these estimates to identify probabilities of normal cognition based on the number of abnormal test scores observed. Abnormal scores were common in the standardization sample (65.4% scoring below a scaled score of 7 on at least one subtest) and more common in the mixed clinical sample (85.6% scoring below a scaled score of 7 on at least one subtest). Probabilities varied according to the number of abnormal test scores, base rates of normal cognition, and cutoff scores. The results suggest that interpretation of base rates obtained from cognitively healthy samples must also account for data from cognitively impaired samples. Bayes' theorem can help neuropsychologists answer questions about the probability that an individual examinee is cognitively healthy based on the number of abnormal test scores observed.
Carbon Dioxide Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit
NASA Technical Reports Server (NTRS)
Korona, F. Adam; Norcross, Jason; Conger, Bruce; Navarro, Moses
2014-01-01
Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy, and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject, and physiological differences between subjects. Computational Fluid Dynamics (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit, and the Enhanced Mobility Advanced Crew Escape Suit. Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.
How much does a reminder letter increase cervical screening among under-screened women in NSW?
Morrell, Stephen; Taylor, Richard; Zeckendorf, Sue; Niciak, Amanda; Wain, Gerard; Ross, Jayne
2005-02-01
To evaluate a direct mail-out campaign to increase Pap screening rates in women who have not had a test in 48 months. Ninety thousand under-screened women were randomised to be mailed a 48-month reminder letter to have a Pap test (n=60,000), or not to be mailed a letter (n=30,000). Differences in Pap test rates were assessed by Kaplan-Meier survival analysis, by chi2 tests of significance between Pap test rates in letter versus no-letter groups, and by proportional hazards regression modelling of predictors of a Pap test with letter versus no-letter as the main study variable. T-tests were conducted on mean time to Pap test to assess whether time to Pap test was significantly different between the intervention and control groups. After 90 days following each mail-out, Pap test rates in the letter group were significantly higher than in the non-letter group, by approximately two percentage points. After controlling for potential confounders, the hazard ratio of a Pap test within 90 days of a mail-out in the letter group was 1.5 compared with 1.0 in the no-letter group. Hazard ratios of having a Pap test within 90 days decreased significantly with time since last Pap test (p<0.0001); were significantly higher than 1.0 for most non-metropolitan areas of NSW compared with metropolitan areas; and increased significantly with age (p<0.0001). Pap test hazard ratios were not associated with socio-economic status of area of residence, but the hazard ratio was significantly higher than 1.0 if the reminder letter was sent after the Christmas/New Year break. No significant differences in mean time to Pap test were found between the letter and no-letter groups. Being sent a reminder letter is associated with higher Pap testing rates in under-screened women.
[The maximum heart rate in the exercise test: the 220-age formula or Sheffield's table?].
Mesquita, A; Trabulo, M; Mendes, M; Viana, J F; Seabra-Gomes, R
1996-02-01
To determine in the maximum cardiac rate in exercise test of apparently healthy individuals may be more properly estimated through 220-age formula (Astrand) or the Sheffield table. Retrospective analysis of clinical history and exercises test of apparently healthy individuals submitted to cardiac check-up. Sequential sampling of 170 healthy individuals submitted to cardiac check-up between April 1988 and September 1992. Comparison of maximum cardiac rate of individuals studied by the protocols of Bruce and modified Bruce, in interrupted exercise test by fatigue, and with the estimated values by the formulae: 220-age versus Sheffield table. The maximum cardiac heart rate is similar with both protocols. This parameter in normal individuals is better predicted by the 220-age formula. The theoretic maximum cardiac heart rate determined by 220-age formula should be recommended for a healthy, and for this reason the Sheffield table has been excluded from our clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, Albert A.; Pegg, I. L.; Chaudhuri, M.
2013-11-13
The principal objective of the work reported here was to develop and identify HLW glass compositions that maximize waste processing rates for the aluminum limted waste composition specified by ORP while maintaining high waste loadings and acceptable glass properties. This was accomplished through a combination of crucible-scale tests, confirmation tests on the DM100 melter system, and demonstration at pilot scale (DM1200). The DM100-BL unit was selected for these tests since it was used previously with the HLW waste streams evaluated in this study, was used for tests on HLW glass compositions to support subsequent tests on the HLW Pilot Melter,more » conduct tests to determine the effect of various glass properties (viscosity and conductivity) and oxide concentrations on glass production rates with HLW feed streams, and to assess the volatility of cesium and technetium during the vitrification of an HLW AZ-102 composition. The same melter was selected for the present tests in order to maintain comparisons between the previously collected data. These tests provide information on melter processing characteristics and off-gas data, including formation of secondary phases and partitioning. Once DM100 tests were completed, one of the compositions was selected for further testing on the DM1200; the DM1200 system has been used for processing a variety of simulated Hanford waste streams. Tests on the larger melter provide processing data at one third of the scale of the actual WTP HLW melter and, therefore, provide a more accurate and reliable assessment of production rates and potential processing issues. The work focused on maximizing waste processing rates for high aluminum HLW compositions. In view of the diversity of forms of aluminum in the Hanford tanks, tests were also conducted on the DM100 to determine the effect of changes in the form of aluminum on feed properties and production rate. In addition, the work evaluated the effect on production rate of modest increases in melter operating temperature. Glass composition development was based on one of the HLW waste compositions specified by ORP that has a high concentration of aluminum. Small-scale tests were used to provide an initial screening of various glass formulations with respect to melt rates; more definitive screening was provided by the subsequent DM100 tests. Glass properties evaluated included: viscosity, electrical conductivity, crystallinity, gross glass phase separation and the 7- day Product Consistency Test (ASTM-1285). Glass property limits were based upon the reference properties for the WTP HLW melter. However, the WTP crystallinity limit (< 1 vol% at 950oC) was relaxed slightly as a waste loading constraint for the crucible melts.« less
Krueger, C.J.; Radakovich, K.M.; Sawyer, T.E.; Barber, L.B.; Smith, R.L.; Field, J.A.
1998-01-01
Transport and biodegradation of linear alkylbenzenesulfonate (LAS) in sewage-contaminated groundwater were investigated for a range of dissolved oxygen concentrations. Both laboratory column and an 80-day continuous injection tracer test field experiments were conducted. The rates of LAS biodegradation increased with increasing dissolved oxygen concentrations and indicated the preferential biodegradation of the longer alkyl chain LAS homologues (i.e., C12 and C13) and external isomers (i.e., 2-and 3- phenyl). However, for similar dissolved oxygen concentrations, mass removal rates for LAS generally were 2-3 times greater in laboratory column experiments than in the field tracer test. Under low oxygen conditions (<1 mg/L) only a fraction of the LAS mixture biodegraded in both laboratory and field experiments. Biodegradation rate constants for the continuous injection field test (0.002-0.08 day-1) were comparable to those estimated for a 3-h injection (pulsed) tracer test conducted under similar biogeochemical conditions, indicating that increasing the exposure time of aquifer sediments to LAS did not increase biodegradation rates.Transport and biodegradation of linear alkylbenzenesulfonate (LAS) in sewage-contaminated groundwater were investigated for a range of dissolved oxygen concentrations. Both laboratory column and an 80-day continuous injection tracer test field experiments were conducted. The rates of LAS biodegradation increased with increasing dissolved oxygen concentrations and indicated the preferential biodegradation of the longer alkyl chain LAS homologues (i.e., C12 and C13) and external isomers (i.e., 2- and 3-phenyl). However, for similar dissolved oxygen concentrations, mass removal rates for LAS generally were 2-3 times greater in laboratory column experiments than in the field tracer test. Under low oxygen conditions (<1 mg/L) only a fraction of the LAS mixture biodegraded in both laboratory and field experiments. Biodegradation rate constants for the continuous injection field test (0.002-0.08 day-1) were comparable to those estimated for a 3-h injection (pulsed) tracer test conducted under similar biogeochemical conditions, indicating that increasing the exposure time of aquifer sediments to LAS did not increase biodegradation rates.
Harrison, Mark; Birch, Stephen; Eden, Martin; Ramsden, Simon; Farragher, Tracey; Payne, Katherine; Hall, Georgina; Black, Graeme Cm
2015-04-01
This study aims to identify and quantify the extent of current variation in service provision of a genetic testing service for dominant and X-linked retinal dystrophies in the English National Health Service (NHS). National audit data (all test requests and results (n = 1839) issued between 2003 and 2011) and survey of English regional genetic testing services were used. Age- and gender-adjusted standardised testing rates were calculated using indirect standardisation, and survey responses were transcribed verbatim and data collated and summarised. The cumulative incidence rate of testing in England was 4.5 per 100,000 population for males and 2.6 per 100,000 population for females. The standardised testing rate (STR) varied widely between regions of England, being particularly low in the North-east (STR 0.485), with half as many tests as expected based on the size and demographic distribution of the population and high in the South-east (STR 1.355), with 36 % more tests than expected. Substantial and significantly different rates of testing were found between regional populations. Specific policy mechanisms to promote, monitor and evaluate the regional distribution of access to genetic and genomic testing are required. However, commissioners will require information on the scope and role of genetic services and the population at risk of the conditions for which patients are tested.
Barbee, Lindley A; Tat, Susana; Dhanireddy, Shireesha; Marrazzo, Jeanne M
2016-06-01
Rates of screening for bacterial sexually transmitted infections (STI) among men who have sex with men in HIV care settings remain low despite high prevalence of these infections. STI self-testing may help increase screening rates in clinical settings. We implemented an STI self-testing program at a large, urban HIV care clinic and evaluated its effectiveness and acceptability. We compared measures obtained during the first year of the STI self-testing program (Intervention Year, April 1, 2013-March 31, 2014) to Baseline Year (January 1, 2012-December 31, 2012) to determine: (1) overall clinic change in STI testing coverage and diagnostic yield and; (2) program-specific outcomes including appropriate anatomic site screening and patient-reported acceptability. Overall, testing for gonorrhea and chlamydia increased significantly between Baseline and Intervention Year, and 50% more gonococcal and 47% more chlamydial infections were detected. Syphilis testing coverage remained unchanged. Nearly 95% of 350 men who participated in the STI self-testing program completed site-specific testing appropriately based on self-reported exposures, and 92% rated their self-testing experience as "good" or "very good." STI self-testing in HIV care settings significantly increases testing coverage and detection of gonorrhea and chlamydia, and the program is acceptable to patients. Additional interventions to increase syphilis screening rates are needed.
Moore, Murray E; Kennedy, Trevor J; Dimmerling, Paul J
2007-11-01
The Radiation Protection Group at the Los Alamos National Laboratory has a wind tunnel capable of measuring the aerosol collection efficiencies of air sampling devices. In the fall of 2005, the group received an internal Los Alamos request to perform aerosol collection efficiency tests on two air samplers manufactured by the Bladewerx Corporation (Rio Rancho, NM). This paper presents the results from tests performed in the wind tunnel facility at a test velocity of 0.5 m s. The SabreAlert (Portable Workplace Monitor) and the SabreBZM (Breathing Zone Monitor) are both designed to detect and measure the presence of alpha emitting isotopes in atmospheres. The SabreAlert was operated at two test air flow rates of 6 and 45 liters per minute (LPM), and the SabreBZM was operated at two test air flow rates of 3 and 19 LPM. The aerosol collection efficiencies of both samplers were evaluated with oleic acid (monodisperse) liquid droplet aerosols tagged with sodium fluorescein tracer. These test aerosols varied in size from about 2.3 to 17.2 microns (aerodynamic equivalent diameter). The SabreAlert was roughly 100% efficient in aerosol collection at a flow rate of 6 LPM, and had an aerodynamic cutpoint diameter of 11.3 microns at the 45 LPM flow rate. The SabreBZM had an aerodynamic cutpoint diameter of 6.7 microns at the 3 LPM flow rate, but the SabreBZM aerosol collection efficiency never exceeded 13.6% at the 19 LPM test flow rate condition.
Intraoperatively Testing the Anastomotic Integrity of Esophagojejunostomy Using Methylene Blue.
Celik, S; Almalı, N; Aras, A; Yılmaz, Ö; Kızıltan, R
2017-03-01
Intraoperative testing of gastrointestinal anastomosis effectively ensures anastomotic integrity. This study investigated whether the routine use of methylene blue intraoperatively identified leaks to reduce the postoperative proportion of clinical leaks. This study retrospectively analyzed consecutive total gastrectomies performed from January 2007 to December 2014 in a university hospital setting by a general surgical group that exclusively used the methylene blue test. All surgeries were performed for gastric or junctional cancers (n = 198). All reconstructions (Roux-en Y esophagojejunostomy) were performed using a stapler. The methylene blue test was used in 108 cases (group 1) via a nasojejunal tube. No test was performed for the other 90 cases (group 2). Intraoperative leakage rate, postoperative clinical leakage rate, length of hospitalization, and mortality rate were the outcome measures. The intraoperative leakage rate was 7.4% in group 1. The postoperative clinical leakage rate was 8.6%. The postoperative clinical leakage rate was 3.7% in group 1 and 14.4% in group 2 (p = 0.007). There were no postoperative clinical leaks when an intraoperative leak led to concomitant intraoperative repair. The median length of hospital stay was 6 days in group 1 and 8 days in group 2 (p < 0.001). One death occurred in each group. No test-related complications were observed. The methylene blue test for esophagojejunostomy is a safe and reliable method for the assessment of anastomosis integrity, especially in cases with difficult esophagojejunostomic construction.
Bremner-Harrison, Samantha; Cypher, Brian L; Van Horn Job, Christine; Harrison, Stephen W R
2018-01-01
Utilisation of animal personality has potential benefit for conservation management. Due to logistics of robust behavioural evaluation in situ, the majority of studies on wild animals involve taking animals into captivity for testing, potentially compromising results. Three in situ tests for evaluation of boldness in San Joaquin kit fox ( Vulpes macrotis mutica ) were developed (ENOT: extended novel object test; RNOT: rapid novel object test; TH: trap/handling test). Each test successfully identified variation in boldness within its target age class(es). The TH test was suitable for use across all age classes. Tests were assessed for in situ suitability and for quantity/quality of data yielded. ENOT was rated as requiring high levels of time, cost and labour with greater likelihood of failure. However, it was rated highly for data quantity/quality. The TH test was rated as requiring little time, labour and cost, but yielding lower quality data. RNOT was rated in the middle. Each test had merit and could be adapted to suit project or species constraints. We recommend field-based evaluation of personality, reducing removal of animals from the wild and facilitating routine incorporation of personality assessment into conservation projects.
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Gyekenyesi, John P.
2000-01-01
Slow crack growth analysis was performed with three different loading histories including constant stress-rate/constant stress-rate testing (Case 1 loading), constant stress/constant stress-rate testing (Case 2 loading), and cyclic stress/constant stress-rate testing (Case 2 loading). Strength degradation due to slow crack growth and/or damage accumulation was determined numerically as a function of percentage of interruption time between the two loading sequences for a given loading history. The numerical solutions were examined with the experimental data determined at elevated temperatures using four different advanced ceramic materials, two silicon nitrides, one silicon carbide and one alumina for the Case 1 loading history, and alumina for the Case 3 loading history. The numerical solutions were in reasonable agreement with the experimental data, indicating that notwithstanding some degree of creep deformation presented for some test materials slow crack growth was a governing mechanism associated with failure for all the test materials.
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Gyekenyesi, John P.
2000-01-01
Slow crack growth analysis was performed with three different loading histories including constant stress-rate/constant stress-rate testing (Case I loading), constant stress/constant stress-rate testing (Case II loading), and cyclic stress/constant stress-rate testing (Case III loading). Strength degradation due to slow crack growth arid/or damage accumulation was determined numerically as a Function of percentage of interruption time between the two loading sequences for a given loading history. The numerical solutions were examined with the experimental data determined at elevated temperatures using four different advanced ceramic materials, two silicon nitrides, one silicon carbide and one alumina for the Case I loading history, and alumina for the Case II loading history. The numerical solutions were in reasonable agreement with the experimental data, indicating that notwithstanding some degree of creep deformation presented for some test materials slow crack growth was a governing mechanism associated with failure for all the test material&