Human Schedule Performance, Protocol Analysis, and the "Silent Dog" Methodology
ERIC Educational Resources Information Center
Cabello, Francisco; Luciano, Carmen; Gomez, Inmaculada; Barnes-Holmes, Dermot
2004-01-01
The purpose of the current experiment was to investigate the role of private verbal behavior on the operant performances of human adults, using a protocol analysis procedure with additional methodological controls (the "silent dog" method). Twelve subjects were exposed to fixed ratio 8 and differential reinforcement of low rate 3-s schedules. For…
A simple protocol for NMR analysis of the enantiomeric purity of chiral hydroxylamines.
Tickell, David A; Mahon, Mary F; Bull, Steven D; James, Tony D
2013-02-15
A practically simple three-component chiral derivatization protocol for determining the enantiopurity of chiral hydroxylamines by (1)H NMR spectroscopic analysis is described, involving their treatment with 2-formylphenylboronic acid and enantiopure BINOL to afford a mixture of diastereomeric nitrono-boronate esters whose ratio is an accurate reflection of the enantiopurity of the parent hydroxylamine.
Tickell, David A; Lampard, Emma V; Lowe, John P; James, Tony D; Bull, Steven D
2016-08-05
A practically simple derivatization protocol for determining the enantiopurity of chiral diols by (1)H NMR spectroscopic analysis is described. Diols were treated with 0.5 equiv of 1,3-phenyldiboronic acid to afford mixtures of diastereomeric boronate esters whose homochiral/heterochiral ratios are an accurate reflection of the diol's enantiopurity.
A method for meta-analysis of epidemiological studies.
Einarson, T R; Leeder, J S; Koren, G
1988-10-01
This article presents a stepwise approach for conducting a meta-analysis of epidemiological studies based on proposed guidelines. This systematic method is recommended for practitioners evaluating epidemiological studies in the literature to arrive at an overall quantitative estimate of the impact of a treatment. Bendectin is used as an illustrative example. Meta-analysts should establish a priori the purpose of the analysis and a complete protocol. This protocol should be adhered to, and all steps performed should be recorded in detail. To aid in developing such a protocol, we present methods the researcher can use to perform each of 22 steps in six major areas. The illustrative meta-analysis confirmed previous traditional narrative literature reviews that Bendectin is not related to teratogenic outcomes in humans. The overall summary odds ratio was 1.01 (chi 2 = 0.05, p = 0.815) with a 95 percent confidence interval of 0.66-1.55. When the studies were separated according to study type, the summary odds ratio for cohort studies was 0.95 with a 95 percent confidence interval of 0.62-1.45. For case-control studies, the summary odds ratio was 1.27 with a 95 percent confidence interval of 0.83-1.94. The corresponding chi-square values were not statistically significant at the p = 0.05 level.
Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng
2013-01-01
Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method.
GAPR2: A DTN Routing Protocol for Communications in Challenged, Degraded, and Denied Environments
2015-09-01
Transmission Speed Vs. Latency Figure 4.7: Helsinki Simulation Set 2, High Network Load and Small Buffers Analysis of Delivery Ratio in Helsinki Simulation...ipnsig.org/. [17] MANET routing, class notes for CS4554: Network modeling and analysis . 119 [18] S. Basagni et al. Mobile ad hoc networking . John...Wiley & Sons, 2004. [19] E. Royer et al. A review of current routing protocols for ad hoc mobile wireless networks . Personal Communications, IEEE, 6(2
Comparing Usual Care With a Warfarin Initiation Protocol After Mechanical Heart Valve Replacement.
Roberts, Gregory; Razooqi, Rasha; Quinn, Stephen
2017-03-01
The immediate postoperative warfarin sensitivity for patients receiving heart valve prostheses is increased. Established warfarin initiation protocols may lack clinical applicability, resulting in dosing based on clinical judgment. To compare current practice for warfarin initiation with a known warfarin initiation protocol, with doses proportionally reduced to account for the increased postoperative sensitivity. We compared the Mechanical Heart Valve Warfarin Initiation Protocol (Protocol group) with current practice (clinical judgment-Empirical group) for patients receiving mechanical heart valves in an observational before-and-after format. End points were the time to achieve a stable therapeutic international normalized ratio (INR), doses held in the first 6 days, and overanticoagulation in the first 6 days. The Protocol group (n = 37) achieved a stable INR more rapidly than the Empirical group (n = 77; median times 5.1 and 8.7 days, respectively; P = 0.002). Multivariable analysis indicated that the Protocol group (hazard ratio [HR] = 2.22; P = 0.005) and men (HR = 1.76; P = 0.043) more rapidly achieved a stable therapeutic INR. Age, serum albumin, amiodarone, presence of severe heart failure, and surgery type had no impact. Protocol patients had fewer doses held (1.1% vs 10.1%, P < 0.001) and no difference in overanticoagulation (2.7% vs 9.1%, P = 0.27). The Mechanical Heart Valve Warfarin Initiation Protocol provided a reliable approach to initiating warfarin in patients receiving mechanical aortic or mitral valves.
Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng
2013-01-01
Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method. PMID:24358286
Yang, Xin-Jun; Yan, Hong-Tao; Nakahori, Yutaka
2003-08-01
To evaluate the effectiveness of laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) for correcting myopia. Study selection, data extraction, and quality assessment were performed by two of authors independently. Summary odds ratios and 95% confidence intervals were calculated by DerSimonian & Laird random-effects model and Mantel-Haenszel (fixed-effects) model. All calculations were based on an intention-to-treat and per protocol analysis. Five hundred and eighty eyes (476 patients) from 5 randomized controlled trials were included in this study. At > or = 6 months follow-up, by random-effects model, the pooled odds ratios (OR, for LASIK vs. PRK) of postoperative uncorrected visual acuity (UCVA) of 20/20 or better for all trials were 1.31 (95% CI=0.77-2.22) by per protocol analysis and 1.18 (95% CI=0.74-1.88) by intention-to-treat analysis. In the refractive outcome, the pooled OR of the postoperative spherical equivalent refraction within +/-0.5 diopter (D) of emmetropia did not show any statistical significance, for which the OR were 0.75 (95% CI=0.48-1.18) by per protocol analysis and 0.70 (95% CI=0.47-1.04) by intention-to-treat analysis. LASIK and PRK were found to be similarly effective for the correction of myopia from -1.5 to -15.0 D in a greater than 6 month follow-up.
Coconut coir pith lignin: A physicochemical and thermal characterization.
Asoka Panamgama, L; Peramune, P R U S K
2018-07-01
The structural and thermal features of coconut coir pith lignin, isolated by three different extraction protocols incorporating two different energy supply sources, were characterized by different analytical tools. The three different chemical extraction protocols were alkaline - 7.5% (w/v) NaOH, organosolv - 85% (v/v) formic and acetic acids at 7:3 (v/v) ratio and polyethylene glycol (PEG): water ratio at 80:20wt%. The two sources of energy were thermal or microwave. Raw lignins were modified by epichlorohydrin to enhance reactivity, and the characteristics of raw and modified lignins were comparatively analysed. Using the thermal energy source, the alkaline and organosolv processes obtained the highest and lowest lignin yields of 26.4±1.5wt% and 3.4±0.2wt%, respectively, as shown by wet chemical analysis. Specific functional group analysis by Fourier transform infrared spectra (FTIR) revealed that significantly different amounts of hydroxyl and carbonyl groups exist in alkaline, organosolv and PEG lignins. Thermogravimetric analysis (TGA) illustrated that the lowest degradation onset temperature was recorded for organosolv lignin, and the overall order was organosolv
Vaganan, M Mayil; Sarumathi, S; Nandakumar, A; Ravi, I; Mustaffa, M M
2015-02-01
Four protocols viz., the trichloroacetic acid-acetone (TCA), phenol-ammonium acetate (PAA), phenol/SDS-ammonium acetate (PSA) and trisbase-acetone (TBA) were evaluated with modifications for protein extraction from banana (Grand Naine) roots, considered as recalcitrant tissues for proteomic analysis. The two-dimensional electrophoresis (2-DE) separated proteins were compared based on protein yield, number of resolved proteins, sum of spot quantity, average spot intensity and proteins resolved in 4-7 pI range. The PAA protocol yielded more proteins (0.89 mg/g of tissues) and protein spots (584) in 2-DE gel than TCA and other protocols. Also, the PAA protocol was superior in terms of sum of total spot quantity and average spot intensity than TCA and other protocols, suggesting phenol as extractant and ammonium acetate as precipitant of proteins were the most suitable for banana rooteomics analysis by 2-DE. In addition, 1:3 ratios of root tissue to extraction buffer and overnight protein precipitation were most efficient to obtain maximum protein yield.
Saade, Charbel; Mohamad, May; Kerek, Racha; Hamieh, Nadine; Alsheikh Deeb, Ibrahim; El-Achkar, Bassam; Tamim, Hani; Abdul Razzak, Farah; Haddad, Maurice; Abi-Ghanem, Alain S; El-Merhi, Fadi
The aim of this article was to investigate the opacification of the renal vasculature and the urogenital system during computed tomography urography by using a quadruple-phase contrast media in a triphasic scan protocol. A total of 200 patients with possible urinary tract abnormalities were equally divided between 2 protocols. Protocol A used the conventional single bolus and quadruple-phase scan protocol (pre, arterial, venous, and delayed), retrospectively. Protocol B included a quadruple-phase contrast media injection with a triphasic scan protocol (pre, arterial and combined venous, and delayed), prospectively. Each protocol used 100 mL contrast and saline at a flow rate of 4.5 mL. Attenuation profiles and contrast-to-noise ratio of the renal arteries, veins, and urogenital tract were measured. Effective radiation dose calculation, data analysis by independent sample t test, receiver operating characteristic, and visual grading characteristic analyses were performed. In arterial circulation, only the inferior interlobular arteries in both protocols showed a statistical significance (P < 0.05). Venously, the inferior vena cava, proximal and distal renal veins demonstrated a significant opacification reduction in protocol B than in protocol A (P < 0.001). Protocol B showed a significantly higher mean contrast-to-noise ratio than protocol A (protocol B: 22.68 ± 13.72; protocol A: 14.75 ± 5.76; P < 0.001). Radiation dose was significantly reduced in protocol B (7.38 ± 2.22 mSv) than in protocol A (12.28 ± 2.72 mSv) (P < 0.001). Visual grading characteristic (P < 0.027) and receiver operating characteristic (P < 0.0001) analyses demonstrated a significant preference for protocol B. In computed tomography urography, augmented quadruple-phase contrast media and triphasic scan protocol usage increases the image quality at a reduced radiation dose.
NASA Astrophysics Data System (ADS)
Gkinis, Vasileios; Holme, Christian; Morris, Valerie; Thayer, Abigail Grace; Vaughn, Bruce; Kjaer, Helle Astrid; Vallelonga, Paul; Simonsen, Marius; Jensen, Camilla Marie; Svensson, Anders; Maffrezzoli, Niccolo; Vinther, Bo; Dallmayr, Remi
2017-04-01
We present a performance comparison study between two state of the art Cavity Ring Down Spectrometers (Picarro L2310-i, L2140-i). The comparison took place during the Continuous Flow Analysis (CFA) campaign for the measurement of the Renland ice core, over a period of three months. Instant and complete vaporisation of the ice core melt stream, as well as of in-house water reference materials is achieved by accurate control of microflows of liquid into a homemade calibration system by following simple principles of the Hagen-Poiseuille law. Both instruments share the same vaporisation unit in a configuration that minimises sample preparation discrepancies between the two analyses. We describe our SMOW-SLAP calibration and measurement protocols for such a CFA application and present quality control metrics acquired during the full period of the campaign on a daily basis. The results indicate an unprecedented performance for all 3 isotopic ratios (δ2H, δ17O, δ18O ) in terms of precision, accuracy and resolution. We also comment on the precision and accuracy of the second order excess parameters of HD16O and H217O over H218O (Dxs, Δ17O ). To our knowledge these are the first reported CFA measurements at this level of precision and accuracy for all three isotopic ratios. Differences on the performance of the two instruments are carefully assessed during the measurement and reported here. Our quality control protocols extend to the area of low water mixing ratios, a regime in which often atmospheric vapour measurements take place and Cavity Ring Down Analysers show a poorer performance due to the lower signal to noise ratios. We address such issues and propose calibration protocols from which water vapour isotopic analyses can benefit from.
Cai, Xiangran; Zhou, Qingchun; Yu, Juan; Xian, Zhaohui; Feng, Youzhen; Yang, Wencai; Mo, Xukai
2014-10-01
To evaluate the impact of reduced-radiation dual-energy (DE) protocols using 320-detector row computed tomography on the differentiation of urinary calculus components. A total of 58 urinary calculi were placed into the same phantom and underwent DE scanning with 320-detector row computed tomography. Each calculus was scanned 4 times with the DE protocols using 135 kV and 80 kV tube voltage and different tube current combinations, including 100 mA and 570 mA (group A), 50 mA and 290 mA (group B), 30 mA and 170 mA (group C), and 10 mA and 60 mA (group D). The acquisition data of all 4 groups were then analyzed by stone DE analysis software, and the results were compared with x-ray diffraction analysis. Noise, contrast-to-noise ratio, and radiation dose were compared. Calculi were correctly identified in 56 of 58 stones (96.6%) using group A and B protocols. However, only 35 stones (60.3%) and 16 stones (27.6%) were correctly diagnosed using group C and D protocols, respectively. Mean noise increased significantly and mean contrast-to-noise ratio decreased significantly from groups A to D (P <.05). In addition, the effective dose decreased markedly from groups A to D at 3.78, 1.81, 1.07, and 0.37 mSv, respectively. Decreasing the DE tube currents from 100 mA and 570 mA to 50 mA and 290 mA resulted in 96.6% accuracy for urinary calculus component analysis while reducing patient radiation exposure to 1.81 mSv. Further reduction of tube currents may compromise diagnostic accuracy. Copyright © 2014 Elsevier Inc. All rights reserved.
Gariani, Joanna; Martin, Steve P; Botsikas, Diomidis; Becker, Christoph D; Montet, Xavier
2018-06-14
To compare radiation dose and image quality of thoracoabdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (Sinogram Affirmed Iterative Reconstruction) in comparison to standard pitch reconstructed with filtered back projection (FBP) using dual source CT. 114 CT scans (Somatom Definition Flash, Siemens Healthineers, Erlangen, Germany), 39 thoracic scans, 54 thoracoabdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis were performed. Dose differences of the protocols used were compared. Dose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high-pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of volume CT dose index of 75% for thoracic scans, 64% for thoracoabdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors reflected in a reduction of 36% of the dose-length product for thoracic scans. This was not at the detriment of image quality, contrast-to-noise ratio, signal-to-noise ratio and the qualitative image analysis revealed a superior image quality in the high-pitch protocols. The combination of a high pitch protocol with iterative reconstruction allows significant dose reduction in routine chest and abdominal scans whilst maintaining or improving diagnostic image quality, with a further reduction in thoracic scans with stellar detectors. Advances in knowledge: High pitch imaging with iterative reconstruction is a tool that can be used to reduce dose without sacrificing image quality.
Nikkhoo, Mohammad; Hsu, Yu-Chun; Haghpanahi, Mohammad; Parnianpour, Mohamad; Wang, Jaw-Lin
2013-06-01
Finite element analysis is an effective tool to evaluate the material properties of living tissue. For an interactive optimization procedure, the finite element analysis usually needs many simulations to reach a reasonable solution. The meta-model analysis of finite element simulation can be used to reduce the computation of a structure with complex geometry or a material with composite constitutive equations. The intervertebral disc is a complex, heterogeneous, and hydrated porous structure. A poroelastic finite element model can be used to observe the fluid transferring, pressure deviation, and other properties within the disc. Defining reasonable poroelastic material properties of the anulus fibrosus and nucleus pulposus is critical for the quality of the simulation. We developed a material property updating protocol, which is basically a fitting algorithm consisted of finite element simulations and a quadratic response surface regression. This protocol was used to find the material properties, such as the hydraulic permeability, elastic modulus, and Poisson's ratio, of intact and degenerated porcine discs. The results showed that the in vitro disc experimental deformations were well fitted with limited finite element simulations and a quadratic response surface regression. The comparison of material properties of intact and degenerated discs showed that the hydraulic permeability significantly decreased but Poisson's ratio significantly increased for the degenerated discs. This study shows that the developed protocol is efficient and effective in defining material properties of a complex structure such as the intervertebral disc.
Packet-Based Protocol Efficiency for Aeronautical and Satellite Communications
NASA Technical Reports Server (NTRS)
Carek, David A.
2005-01-01
This paper examines the relation between bit error ratios and the effective link efficiency when transporting data with a packet-based protocol. Relations are developed to quantify the impact of a protocol s packet size and header size relative to the bit error ratio of the underlying link. These relations are examined in the context of radio transmissions that exhibit variable error conditions, such as those used in satellite, aeronautical, and other wireless networks. A comparison of two packet sizing methodologies is presented. From these relations, the true ability of a link to deliver user data, or information, is determined. Relations are developed to calculate the optimal protocol packet size forgiven link error characteristics. These relations could be useful in future research for developing an adaptive protocol layer. They can also be used for sizing protocols in the design of static links, where bit error ratios have small variability.
Acupuncture for patients with Alzheimer's disease: a systematic review protocol
Zhou, Jing; Peng, Weina; Li, Wang; Liu, Zhishun
2014-01-01
Introduction The aim of this protocol is to provide the methods used to assess the effectiveness and safety of acupuncture for the treatment of patients with Alzheimer's disease. Methods and analysis We will search the following electronic databases: The Cochrane Library, PubMed, Medline, Embase, PsycINFO, Chinese Biomedical Literature Database, Chinese Medical Current Contents and China National Knowledge Infrastructure without restriction of language and publication status. Other sources such as Chinese acupuncture journals and the reference list of selected studies will also be searched. After screening the studies, a meta-analysis of randomised controlled trials will be conducted, if possible. Results expressed as risk ratios for dichotomous data and standardised or weighted mean differences for continuous data, will be used for data synthesis. Dissemination The protocol of this systematic review will be disseminated in a peer-reviewed journal and presented at a relevant conference. Trial registration number PROSPERO CRD42014009619 PMID:25142265
Pre-Steady-State Kinetic Analysis of Single-Nucleotide Incorporation by DNA Polymerases
Su, Yan; Guengerich, F. Peter
2016-01-01
Pre-steady-state kinetic analysis is a powerful and widely used method to obtain multiple kinetic parameters. This protocol provides a step-by-step procedure for pre-steady-state kinetic analysis of single-nucleotide incorporation by a DNA polymerase. It describes the experimental details of DNA substrate annealing, reaction mixture preparation, handling of the RQF-3 rapid quench-flow instrument, denaturing polyacrylamide DNA gel preparation, electrophoresis, quantitation, and data analysis. The core and unique part of this protocol is the rationale for preparation of the reaction mixture (the ratio of the polymerase to the DNA substrate) and methods for conducting pre-steady-state assays on an RQF-3 rapid quench-flow instrument, as well as data interpretation after analysis. In addition, the methods for the DNA substrate annealing and DNA polyacrylamide gel preparation, electrophoresis, quantitation and analysis are suitable for use in other studies. PMID:27248785
Munro, Sarah A; Lund, Steven P; Pine, P Scott; Binder, Hans; Clevert, Djork-Arné; Conesa, Ana; Dopazo, Joaquin; Fasold, Mario; Hochreiter, Sepp; Hong, Huixiao; Jafari, Nadereh; Kreil, David P; Łabaj, Paweł P; Li, Sheng; Liao, Yang; Lin, Simon M; Meehan, Joseph; Mason, Christopher E; Santoyo-Lopez, Javier; Setterquist, Robert A; Shi, Leming; Shi, Wei; Smyth, Gordon K; Stralis-Pavese, Nancy; Su, Zhenqiang; Tong, Weida; Wang, Charles; Wang, Jian; Xu, Joshua; Ye, Zhan; Yang, Yong; Yu, Ying; Salit, Marc
2014-09-25
There is a critical need for standard approaches to assess, report and compare the technical performance of genome-scale differential gene expression experiments. Here we assess technical performance with a proposed standard 'dashboard' of metrics derived from analysis of external spike-in RNA control ratio mixtures. These control ratio mixtures with defined abundance ratios enable assessment of diagnostic performance of differentially expressed transcript lists, limit of detection of ratio (LODR) estimates and expression ratio variability and measurement bias. The performance metrics suite is applicable to analysis of a typical experiment, and here we also apply these metrics to evaluate technical performance among laboratories. An interlaboratory study using identical samples shared among 12 laboratories with three different measurement processes demonstrates generally consistent diagnostic power across 11 laboratories. Ratio measurement variability and bias are also comparable among laboratories for the same measurement process. We observe different biases for measurement processes using different mRNA-enrichment protocols.
Lelijveld, Natasha; Bailey, Jeanette; Mayberry, Amy; Trenouth, Lani; N'Diaye, Dieynaba S; Haghparast-Bidgoli, Hassan; Puett, Chloe
2018-04-24
Acute malnutrition is currently divided into severe (SAM) and moderate (MAM) based on level of wasting. SAM and MAM currently have separate treatment protocols and products, managed by separate international agencies. For SAM, the dose of treatment is allocated by the child's weight. A combined and simplified protocol for SAM and MAM, with a standardised dose of ready-to-use therapeutic food (RUTF), is being trialled for non-inferior recovery rates and may be more cost-effective than the current standard protocols for treating SAM and MAM. This is the protocol for the economic evaluation of the ComPAS trial, a cluster-randomised controlled, non-inferiority trial that compares a novel combined protocol for treating uncomplicated acute malnutrition compared to the current standard protocol in South Sudan and Kenya. We will calculate the total economic costs of both protocols from a societal perspective, using accounting data, interviews and survey questionnaires. The incremental cost of implementing the combined protocol will be estimated, and all costs and outcomes will be presented as a cost-consequence analysis. Incremental cost-effectiveness ratio will be calculated for primary and secondary outcome, if statistically significant. We hypothesise that implementing the combined protocol will be cost-effective due to streamlined logistics at clinic level, reduced length of treatment, especially for MAM, and reduced dosages of RUTF. The findings of this economic evaluation will be important for policymakers, especially given the hypothesised non-inferiority of the main health outcomes. The publication of this protocol aims to improve rigour of conduct and transparency of data collection and analysis. It is also intended to promote inclusion of economic evaluation in other nutrition intervention studies, especially for MAM, and improve comparability with other studies. ISRCTN 30393230 , date: 16/03/2017.
Bischel, Alexander; Stratis, Andreas; Kakar, Apoorv; Bosmans, Hilde; Jacobs, Reinhilde; Gassner, Eva-Maria; Puelacher, Wolfgang; Pauwels, Ruben
2016-01-01
Objective: The aim of this study was to evaluate whether application of ultralow dose protocols and iterative reconstruction technology (IRT) influence quantitative Hounsfield units (HUs) and contrast-to-noise ratio (CNR) in dentomaxillofacial CT imaging. Methods: A phantom with inserts of five types of materials was scanned using protocols for (a) a clinical reference for navigated surgery (CT dose index volume 36.58 mGy), (b) low-dose sinus imaging (18.28 mGy) and (c) four ultralow dose imaging (4.14, 2.63, 0.99 and 0.53 mGy). All images were reconstructed using: (i) filtered back projection (FBP); (ii) IRT: adaptive statistical iterative reconstruction-50 (ASIR-50), ASIR-100 and model-based iterative reconstruction (MBIR); and (iii) standard (std) and bone kernel. Mean HU, CNR and average HU error after recalibration were determined. Each combination of protocols was compared using Friedman analysis of variance, followed by Dunn's multiple comparison test. Results: Pearson's sample correlation coefficients were all >0.99. Ultralow dose protocols using FBP showed errors of up to 273 HU. Std kernels had less HU variability than bone kernels. MBIR reduced the error value for the lowest dose protocol to 138 HU and retained the highest relative CNR. ASIR could not demonstrate significant advantages over FBP. Conclusions: Considering a potential dose reduction as low as 1.5% of a std protocol, ultralow dose protocols and IRT should be further tested for clinical dentomaxillofacial CT imaging. Advances in knowledge: HU as a surrogate for bone density may vary significantly in CT ultralow dose imaging. However, use of std kernels and MBIR technology reduce HU error values and may retain the highest CNR. PMID:26859336
Cho, Eun-Suk; Kim, Joo Hee; Kim, Sungjun; Yu, Jeong-Sik; Chung, Jae-Joon; Yoon, Choon-Sik; Lee, Hyeon-Kyeong; Lee, Kyung Hee
2012-01-01
To prospectively investigate the feasibility of an 80-kilovolt (peak) (kVp) protocol in computed tomographic venography for varicose veins of the lower extremities by comparison with conventional 120-kVp protocol. Attenuation values and signal-to-noise ratio of iodine contrast medium (CM) were determined in a water phantom for 2 tube voltages (80 kVp and 120 kVp). Among 100 patients, 50 patients were scanned with 120 kVp and 150 effective milliampere second (mAs(eff)), and the other 50 patients were scanned with 80 kVp and 390 mAs(eff) after the administration of 1.7-mL/kg CM (370 mg of iodine per milliliter). The 2 groups were compared for venous attenuation, contrast-to-noise ratio, and subjective degree of venous enhancement, image noise, and overall diagnostic image quality. In the phantom, the attenuation value and signal-to-noise ratio value for iodine CM at 80 kVp were 63.8% and 33.0% higher, respectively, than those obtained at 120 kVp. The mean attenuation of the measured veins of the lower extremities was 148.3 Hounsfield units (HU) for the 80-kVp protocol and 94.8 HU for the 120-kVp protocol. Contrast-to-noise ratio was also significantly higher with the 80-kVp protocol. The overall diagnostic image quality of the 3-dimensional volume-rendered images was good with both protocols. The subjective score for venous enhancement was higher at the 80-kVp protocol. The mean volume computed tomography dose index of the 80-kVp (5.6 mGy) protocol was 23.3% lower than that of the 120-kVp (7.3 mGy) protocol. The use of the 80-kVp protocol improved overall venous attenuation, especially in perforating vein, and provided similarly high diagnostic image quality with a lower radiation dose when compared to the conventional 120-kVp protocol.
Naik, Bhiken I; Tsang, Siny; Knisely, Anne; Yerra, Sandeep; Durieux, Marcel E
2017-01-31
Enhanced recovery after surgery (ERAS) programs typically utilizes multi-modal analgesia to reduce perioperative opioid consumption. Systemic lidocaine is used in several of these ERAS algorithms and has been shown to reduce opioid use after colorectal surgery. However it is unclear how much the other components of an ERAS protocol contribute to the final outcome. Using a noninferiority analysis we sought to assess the role of perioperative lidocaine in an ERAS program for colorectal surgery, using pain and opioid consumption as outcomes. We conducted a retrospective review of patients who had received intravenous lidocaine perioperatively during colorectal surgery. We matched them with patients who were managed using a multi-component ERAS protocol, which included perioperative lidocaine. We tested a joint hypothesis of noninferiority of lidocaine infusion to ERAS protocol in postoperative pain scores and opioid consumption. We assigned a noninferiority margin of 1 point (on an 11-point numerical rating scale) difference in pain and a ratio [mean (lidocaine) / mean (ERAS)] of 1.2 in opioid consumption, respectively. Fifty-two patients in the lidocaine group were matched with patients in the ERAS group. With regards to opioid consumption, in the overall [1.68 (1.43-1.98)] [odds ratio (95% confidence interval)] analysis and on postoperative day (POD) 1 [2.38 (1.74-3.31)] lidocaine alone was inferior to multi-modal analgesia. On POD 2 and beyond, although the mean odds ratio for opioid consumption was 1.43 [1.43 (1.17-1.73)], the lower limit extended beyond the pre-defined cut-off of 1.2, rendering the outcome inconclusive. For pain scores lidocaine is non-inferior to ERAS [-0.17 (-1.08-0.74)] on POD 2 and beyond. Pain scores on POD 1 and in the overall cohort were inconclusive based on the noninferiority analysis. The addition of a multi-component ERAS protocol to intravenous lidocaine incrementally reduces opioid consumption, most evident on POD 1. For pain scores the data is inconclusive on POD 1, however on POD 2 and beyond lidocaine alone is non-inferior to an ERAS program with lidocaine. Opioid-related complications, including return of bowel function, were not different between the groups despite reduced opioid use in the ERAS group.
Balliana, Eleonora; Aramendía, Maite; Resano, Martin; Barbante, Carlo; Vanhaecke, Frank
2013-03-01
Although in many cases Pb isotopic analysis can be relied on for provenance determination of ancient bronzes, sometimes the use of "non-traditional" isotopic systems, such as those of Cu and Sn, is required. The work reported on in this paper aimed at revising the methodology for Cu and Sn isotope ratio measurements in archaeological bronzes via optimization of the analytical procedures in terms of sample pre-treatment, measurement protocol, precision, and analytical uncertainty. For Cu isotopic analysis, both Zn and Ni were investigated for their merit as internal standard (IS) relied on for mass bias correction. The use of Ni as IS seems to be the most robust approach as Ni is less prone to contamination, has a lower abundance in bronzes and an ionization potential similar to that of Cu, and provides slightly better reproducibility values when applied to NIST SRM 976 Cu isotopic reference material. The possibility of carrying out direct isotopic analysis without prior Cu isolation (with AG-MP-1 anion exchange resin) was investigated by analysis of CRM IARM 91D bronze reference material, synthetic solutions, and archaeological bronzes. Both procedures (Cu isolation/no Cu isolation) provide similar δ (65)Cu results with similar uncertainty budgets in all cases (±0.02-0.04 per mil in delta units, k = 2, n = 4). Direct isotopic analysis of Cu therefore seems feasible, without evidence of spectral interference or matrix-induced effect on the extent of mass bias. For Sn, a separation protocol relying on TRU-Spec anion exchange resin was optimized, providing a recovery close to 100 % without on-column fractionation. Cu was recovered quantitatively together with the bronze matrix with this isolation protocol. Isotopic analysis of this Cu fraction provides δ (65)Cu results similar to those obtained upon isolation using AG-MP-1 resin. This means that Cu and Sn isotopic analysis of bronze alloys can therefore be carried out after a single chromatographic separation using TRU-Spec resin. Tin isotopic analysis was performed relying on Sb as an internal standard used for mass bias correction. The reproducibility over a period of 1 month (n = 42) for the mass bias-corrected Sn isotope ratios is in the range of 0.06-0.16 per mil (2 s), for all the ratios monitored.
Energy Consumption Research of Mobile Data Collection Protocol for Underwater Nodes Using an USV.
Lv, Zhichao; Zhang, Jie; Jin, Jiucai; Li, Qi; Gao, Baoru
2018-04-16
The Unmanned Surface Vehicle (USV) integrated with an acoustic modem is a novel mobile vehicle for data collection, which has an advantage in terms of mobility, efficiency, and collection cost. In the scenario of data collection, the USV is controlled autonomously along the planning trajectory and the data of underwater nodes are dynamically collected. In order to improve the efficiency of data collection and extend the life of the underwater nodes, a mobile data collection protocol for underwater nodes using the USV was proposed. In the protocol, the stop-and-wait ARQ transmission mechanism is adopted, where the duty cycle is designed considering the ratio between the sleep mode and the detection mode, and the transmission ratio is defined by the duty cycle, wake-up signal cycles, and USV’s speed. According to protocol, the evaluation index for energy consumption is constructed based on the duty cycle and the transmission ratio. The energy consumption of the protocol is simulated and analyzed using the mobile communication experiment data of USV, taking into consideration USV’s speed, data sequence length, and duty cycle. Optimized protocol parameters are identified, which in turn denotes the proposed protocol’s feasibility and effectiveness.
Van Calster, B; Bobdiwala, S; Guha, S; Van Hoorde, K; Al-Memar, M; Harvey, R; Farren, J; Kirk, E; Condous, G; Sur, S; Stalder, C; Timmerman, D; Bourne, T
2016-11-01
A uniform rationalized management protocol for pregnancies of unknown location (PUL) is lacking. We developed a two-step triage protocol to select PUL at high risk of ectopic pregnancy (EP), based on serum progesterone level at presentation (step 1) and the serum human chorionic gonadotropin (hCG) ratio, defined as the ratio of hCG at 48 h to hCG at presentation (step 2). This was a cohort study of 2753 PUL (301 EP), involving a secondary analysis of prospectively and consecutively collected PUL data from two London-based university teaching hospitals. Using a chronological split we used 1449 PUL for development and 1304 for validation. We aimed to assign PUL as low risk with high confidence (high negative predictive value (NPV)) while classifying most EP as high risk (high sensitivity). The first triage step assigned PUL as low risk using a threshold of serum progesterone at presentation. The remaining PUL were triaged using a novel logistic regression risk model based on hCG ratio and initial serum progesterone (second step), defining low risk as an estimated EP risk of < 5%. On validation, initial serum progesterone ≤ 2 nmol/L (step 1) classified 16.1% PUL as low risk. Second-step classification with the risk model selected an additional 46.0% of all PUL as low risk. Overall, the two-step protocol classified 62.1% of PUL as low risk, with an NPV of 98.6% and a sensitivity of 92.0%. When the risk model was used in isolation (i.e. without the first step), 60.5% of PUL were classified as low risk with 99.1% NPV and 94.9% sensitivity. PUL can be classified efficiently into being either high or low risk for complications using a two-step protocol involving initial progesterone and hCG levels and the hCG ratio. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
A native Bayesian classifier based routing protocol for VANETS
NASA Astrophysics Data System (ADS)
Bao, Zhenshan; Zhou, Keqin; Zhang, Wenbo; Gong, Xiaolei
2016-12-01
Geographic routing protocols are one of the most hot research areas in VANET (Vehicular Ad-hoc Network). However, there are few routing protocols can take both the transmission efficient and the usage of ratio into account. As we have noticed, different messages in VANET may ask different quality of service. So we raised a Native Bayesian Classifier based routing protocol (Naive Bayesian Classifier-Greedy, NBC-Greedy), which can classify and transmit different messages by its emergency degree. As a result, we can balance the transmission efficient and the usage of ratio with this protocol. Based on Matlab simulation, we can draw a conclusion that NBC-Greedy is more efficient and stable than LR-Greedy and GPSR.
Thomas, Christoph; Krauss, Bernhard; Ketelsen, Dominik; Tsiflikas, Ilias; Reimann, Anja; Werner, Matthias; Schilling, David; Hennenlotter, Jörg; Claussen, Claus D; Schlemmer, Heinz-Peter; Heuschmid, Martin
2010-07-01
In dual energy (DE) computed tomography (CT), spectral shaping by additional filtration of the high energy spectrum can theoretically improve dual energy contrast. The aim of this in vitro study was to examine the influence of an additional tin filter for the differentiation of human urinary calculi by dual energy CT. A total of 36 pure human urinary calculi (uric acid, cystine, calciumoxalate monohydrate, calciumoxalate dihydrate, carbonatapatite, brushite, average diameter 10.5 mm) were placed in a phantom and imaged with 2 dual source CT scanners. One scanner was equipped with an additional tin (Sn) filter. Different combinations of tube voltages (140/80 kV, 140/100 kV, Sn140/100 kV, Sn140/80 kV, with Sn140 referring to 140 kV with the tin filter) were applied. Tube currents were adapted to yield comparable dose indices. Low- and high energy images were reconstructed. The calculi were segmented semiautomatically in the datasets and DE ratios (attenuation@low_kV/attenuation@high_kV) and were calculated for each calculus. DE contrasts (DE-ratio_material1/DE-ratio_material2) were computed for uric acid, cystine and calcified calculi and compared between the combinations of tube voltages. Using exclusively DE ratios, all uric acid, cystine and calcified calculi (as a group) could be differentiated in all protocols; the calcified calculi could not be differentiated among each other in any examination protocol. The highest DE ratios and DE contrasts were measured for the Sn140/80 protocol (53%-62% higher DE contrast than in the 140/80 kV protocol without additional filtration). The DE ratios and DE contrasts of the 80/140 kV and 100/Sn140 kV protocols were comparable. Uric acid, cystine and calcified calculi could be reliably differentiated by any of the protocols. A dose-neutral gain of DE contrast was found in the Sn-filter protocols, which might improve the differentiation of smaller calculi (Sn140/80 kV) and improve image quality and calculi differentiation in larger patients (Sn140/100 kV). However, even with the improved spectral separation of the Sn-filter protocols, the DE ratios of calcified calculi are not sufficiently distinct to allow a differentiation within this group.
NASA Astrophysics Data System (ADS)
Saiful Huq, M.; Andreo, Pedro; Song, Haijun
2001-11-01
The International Atomic Energy Agency (IAEA TRS-398) and the American Association of Physicists in Medicine (AAPM TG-51) have published new protocols for the calibration of radiotherapy beams. These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standards laboratory's reference quality beam. This paper compares the recommendations of the two protocols in two ways: (i) by analysing in detail the differences in the basic data included in the two protocols for photon and electron beam dosimetry and (ii) by performing measurements in clinical photon and electron beams and determining the absorbed dose to water following the recommendations of the two protocols. Measurements were made with two Farmer-type ionization chambers and three plane-parallel ionization chamber types in 6, 18 and 25 MV photon beams and 6, 8, 10, 12, 15 and 18 MeV electron beams. The Farmer-type chambers used were NE 2571 and PTW 30001, and the plane-parallel chambers were a Scanditronix-Wellhöfer NACP and Roos, and a PTW Markus chamber. For photon beams, the measured ratios TG-51/TRS-398 of absorbed dose to water Dw ranged between 0.997 and 1.001, with a mean value of 0.999. The ratios for the beam quality correction factors kQ were found to agree to within about +/-0.2% despite significant differences in the method of beam quality specification for photon beams and in the basic data entering into kQ. For electron beams, dose measurements were made using direct ND,w calibrations of cylindrical and plane-parallel chambers in a 60Co gamma-ray beam, as well as cross-calibrations of plane-parallel chambers in a high-energy electron beam. For the direct ND,w calibrations the ratios TG-51/TRS-398 of absorbed dose to water Dw were found to lie between 0.994 and 1.018 depending upon the chamber and electron beam energy used, with mean values of 0.996, 1.006, and 1.017, respectively, for the cylindrical, well-guarded and not well-guarded plane-parallel chambers. The Dw ratios measured for the cross-calibration procedures varied between 0.993 and 0.997. The largest discrepancies for electron beams between the two protocols arise from the use of different data for the perturbation correction factors pwall and pdis of cylindrical and plane-parallel chambers, all in 60Co. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors and the quantities in the two protocols.
Eriksson, Bjorn O.; Docherty Skogh, Ann-Charlott; Sommar, Pehr; Hammarstedt, Lalle; Gahm, Caroline
2017-01-01
Background: The impact of preoperative radiotherapy on microvascular reconstructive surgery outcome has been a subject of debate. However, data are conflicting and often dependent on local treatment protocols. We have studied the effects of radiotherapy in a unique, single-center setting where a treatment protocol change was undertaken from pre- to postoperative radiotherapy administration for microsurgical head and neck reconstructions. Methods: A cohort study was conducted for 200 consecutive head and neck free flap cases, where 100 were operated on before and 100 after the treatment protocol adjustment in 2006. Only direct cancer reconstructions were included. Complication rates of anastomosis-related (flap necrosis) and flap bed–related (infection, fistula, and wound dehiscence) complications were compared between irradiated and nonirradiated patients. A multivariate analysis was performed to correct for treatment period. Results: One hundred twenty-six patients had received radiotherapy before reconstruction due to cases of cancer recurrence. There were no significant differences in demographic data or risk factors between irradiated and nonirradiated cases. Irradiated cases had a higher rate of both flap loss (9.5% versus 1.4%; P = 0.034) and flap bed–related complications (29% versus 13%; P = 0.014). However, after multivariate analysis, there was only a significant relationship between preoperative irradiation and infection (odds ratio = 2.51; P = 0.033) and fistula formation (odds ratio = 3.13; P = 0.034). Conclusions: The current single-center study clearly indicates that preoperative radiotherapy is a risk factor for both infection and fistula formation, most likely related to an impaired flap bed. We suggest postoperative radiotherapy administration whenever possible for oncological reasons, otherwise proper antibiotic cover and meticulous flap insetting to prevent radiation-related infection and fistula formation. PMID:28458967
Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari
2014-02-01
Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.
Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima
2014-01-01
Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212
Lablanche, Jean-Marc; Leone, Attilio; Merkely, Bela; Morais, João; Alonso, Joaquim; Santini, Massimo; Eha, Jaan; Demil, Nacima; Licour, Muriel; Tardif, Jean-Claude
2010-03-01
The mechanism underlying statin-induced event reduction in patients with acute coronary syndrome remains unclear. To assess the efficacy of rosuvastatin 20mg versus atorvastatin 80 mg in reducing the apolipoprotein B/apolipoprotein A-1 (apoB/apoA-1) ratio at 3 months. Non-inferiority of rosuvastatin 20mg versus atorvastatin 80 mg in reducing low-density lipoprotein cholesterol at 1 and 3 months was also assessed. Patients with non-ST-elevation acute coronary syndrome were enrolled into this randomized, double blind, parallel-group trial. In total, 753 patients (369, rosuvastatin 20mg; 384, atorvastatin 80 mg) were included in the intention-to-treat analysis; 478 patients (226, rosuvastatin 20mg; 252, atorvastatin 80 mg) were included in the per-protocol analysis. Rosuvastatin 20mg was more effective than atorvastatin 80 mg in decreasing apoB/apoA-1 ratio at 1 month (-44.4% vs -42.9%, p=0.02) but not at 3 months (both -44.4%, p=0.87). Low-density lipoprotein cholesterol decreased by approximately 50% after 1 and 3 months in both groups. Non-inferiority of rosuvastatin 20mg versus atorvastatin 80 mg was demonstrated at 1 month (difference, -0.3% [95% confidence interval, -2.7; +2.1]), but not at 3 months (+1.0% [-1.6; 3.5]) (intention-to-treat analysis). In the per-protocol analysis, non-inferiority of rosuvastatin 20mg was demonstrated at both 1 (-0.7% [-3.5; 2.0]) and 3 (-0.5% [-3.5; 2.5]) months. In patients with non-ST-elevation acute coronary syndrome, rosuvastatin 20mg decreased apoB/apoA-1 ratio at 1 month more than atorvastatin 80 mg. No difference could be shown at 3 months; thus, the primary endpoint was not met.
Galloza, Marina Og; Jordão-Basso, Keren Cf; Bandeca, Matheus C; Costa, Samuel O; Borges, Alvaro H; Tonetto, Mateus R; Tirintan, Fabio C; Keine, Kátia C; Kuga, Milton C
2017-11-01
The aim of this study was to evaluate the effects of bleaching gel using 35% hydrogen peroxide (HP), associated with red carmine pigment (RC), in the 3:1 or 1:1 ratio, on fracture resistance and dentin microhardness of endodontically treated teeth. A total of 40 lower incisors were endodontically treated and divided into four groups (n = 10), according to the bleaching protocol: G1 (HP3), 35% HP + RC (3:1); G2 (HP1), 35% HP + RC (1:1); G3 (positive), 38% HP; and G4 (negative), unbleached. Four dental bleaching sessions were performed. The dental crowns were restored after the last session and submitted to the fracture resistance test. Totally, 60 specimens from the endodontically treated lower incisor crowns were prepared to evaluate the effects on dentin microhardness. The analysis was measured (in Knoop) prior to and after the last dental bleaching session using similar bleaching protocols. G2 presented the lowest fracture resistance (p < 0.05). The other groups were similar to each other (p > 0.05). No difference was observed in the reduction of dentin microhardness among the groups (p > 0.05). A 1:1 ratio (bleaching gel:pigment) caused a significant fracture resistance reduction in relation to the other protocols. No effect on the dentin microhardness reduction was observed. The pigment addition to the bleaching agent accelerates the bleaching chemical reaction. However, no studies have evaluated the ideal proportion to optimize tooth bleaching.
An improved PRoPHET routing protocol in delay tolerant network.
Han, Seung Deok; Chung, Yun Won
2015-01-01
In delay tolerant network (DTN), an end-to-end path is not guaranteed and packets are delivered from a source node to a destination node via store-carry-forward based routing. In DTN, a source node or an intermediate node stores packets in buffer and carries them while it moves around. These packets are forwarded to other nodes based on predefined criteria and finally are delivered to a destination node via multiple hops. In this paper, we improve the dissemination speed of PRoPHET (probability routing protocol using history of encounters and transitivity) protocol by employing epidemic protocol for disseminating message m, if forwarding counter and hop counter values are smaller than or equal to the threshold values. The performance of the proposed protocol was analyzed from the aspect of delivery probability, average delay, and overhead ratio. Numerical results show that the proposed protocol can improve the delivery probability, average delay, and overhead ratio of PRoPHET protocol by appropriately selecting the threshold forwarding counter and threshold hop counter values.
Tsujimoto, Yasushi; Tsujimoto, Hiraku; Kataoka, Yuki; Kimachi, Miho; Shimizu, Sayaka; Ikenoue, Tatsuyoshi; Fukuma, Shingo; Yamamoto, Yosuke; Fukuhara, Shunichi
2017-04-01
To describe the registration of systematic review (SR) protocols and examine whether or not registration reduced the outcome reporting bias in high-impact journals. We searched MEDLINE via PubMed to identify SRs of randomized controlled trials of interventions. We included SRs published between August 2009 and June 2015 in the 10 general and internal medicinal journals with the highest impact factors in 2013. We examined the proportion of SR protocol registration and investigated the relationship between registration and outcome reporting bias using multivariable logistic regression. Among the 284 included reviews, 60 (21%) protocols were registered. The proportion of registration increased from 5.6% in 2009 to 27% in 2015 (P for trend <0.001). Protocol registration was not associated with outcome reporting bias (adjusted odds ratio [OR] 0.85, 95% confidence interval [CI] 0.39-1.86). The association between Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) adherence and protocol registration was not statistically significant (OR 1.09, 95% CI 0.59-2.01). Six years after the launch of the PRISMA statement, the proportion of protocol registration in high-impact journals has increased some but remains low. The present study found no evidence suggesting that protocol registration reduced outcome reporting bias. Copyright © 2017 Elsevier Inc. All rights reserved.
Sobral, Ana Paula Taboada; de Godoy, Camila Leal H; Fernandes, Kristianne P Santos; Bussadori, Sandra Kalil; Ferrari, Raquel Agnelli Mesquita; Monken, Sonia F
2018-01-01
Introduction Epidemiological data show that the signs and symptoms of temporomandibular disorder (TMD) start becoming apparent from 6 years of age, and during adolescence these signs and symptoms are similar to those of adults. The present study aims to estimate the direct costs for treatment of chronic muscle pain with photobiomodulation therapy, occlusal splint and placebo in patients with TMD; to evaluate the effectiveness of photobiomodulation therapy and occlusal splint for treatment of muscle pain in patients with TMD; to analyse the cost-effectiveness of the two proposed treatments for pain; and to describe and compare the results of the analyses of these treatments. Methods and analysis This is a prospective trial of clinical and economic analyses that will include 135 patientswith TMD aged between 15 years and 25 years, randomly assigned to a treatment group: G1 (photobiomodulation), G2 (occlusal splint) and G3 (placebo). The analyses will be based on the cost of each treatment during the 12-month period. The outcome of the analysis of effectiveness will be pain, measured periodically by means of clinical examination of Research Diagnostic Criteria for Temporomandibular Disorders. The cost-effectiveness ratio will be calculated using, as end points, pain and the ratio of the differences in costs between the groups studied. The evaluation of the impact of the treatment on quality of life will be determined by applying the adapted EuroQol-5D. Ethics and dissemination This protocol has been ethically approved by the local medical ethical committee, protocol number 2.014.339. Results will be submitted to international peer-reviewed journals and presented at international conferences. Trial registration number NCT03096301. PMID:29730613
Chen, Xiao; Geng, Ling; Li, Hong
2014-04-01
To compare the clinical outcomes and cost-effectiveness of luteal phase down-regulation with gonadotrophin-releasing hormone (GnRH) agonist protocol and GnRH antagonist protocol in patients undergoing repeated in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) cycles. A retrospective analysis of clinical outcomes and costs was conducted among 198 patients undergoing repeated IVF-ICSI cycles, including 109 receiving luteal phase down-regulation with GnRH agonist protocol (group A) and 89 receiving GnRH antagonist protocol (group B). The numbers of oocytes retrieved and good embryos, clinical pregnancy rate, abortion rate, the live birth rate, mean total cost, and the cost-effective ratio were compared between the two groups. In patients undergoing repeated IVF-ICSI cycles, the two protocols produced no significant differences in the number of good embryos, clinical pregnancy rate, abortion rate, or twin pregnancy rate. Compared with group B, group A had better clinical outcomes though this difference was not statistically significant. The number of retrieved oocytes was significantly greater and live birth rate significantly higher in group A than in group B (9.13=4.98 vs 7.11=4.74, and 20.2% vs 9.0%, respectively). Compared with group B, group A had higher mean total cost per cycle but lower costs for each oocyte retrieved (2729.11 vs 3038.60 RMB yuan), each good embryo (8867.19 vs 9644.85 RMB yuan), each clinical pregnancy (77598.06 vs 96139.85 RMB yuan). For patients undergoing repeated IVF/ICSI cycle, luteal phase down-regulation with GnRH agonist protocol produces good clinical outcomes with also good cost-effectiveness in spite an unsatisfactory ovarian reserve.
An optimized immunohistochemistry protocol for detecting the guidance cue Netrin-1 in neural tissue.
Salameh, Samer; Nouel, Dominique; Flores, Cecilia; Hoops, Daniel
2018-01-01
Netrin-1, an axon guidance protein, is difficult to detect using immunohistochemistry. We performed a multi-step, blinded, and controlled protocol optimization procedure to establish an efficient and effective fluorescent immunohistochemistry protocol for characterizing Netrin-1 expression. Coronal mouse brain sections were used to test numerous antigen retrieval methods and combinations thereof in order to optimize the stain quality of a commercially available Netrin-1 antibody. Stain quality was evaluated by experienced neuroanatomists for two criteria: signal intensity and signal-to-noise ratio. After five rounds of testing protocol variants, we established a modified immunohistochemistry protocol that produced a Netrin-1 signal with good signal intensity and a high signal-to-noise ratio. The key protocol modifications are as follows: •Use phosphate buffer (PB) as the blocking solution solvent.•Use 1% sodium dodecyl sulfate (SDS) treatment for antigen retrieval. The original protocol was optimized for use with the Netrin-1 antibody produced by Novus Biologicals. However, we subsequently further modified the protocol to work with the antibody produced by Abcam. The Abcam protocol uses PBS as the blocking solution solvent and adds a citrate buffer antigen retrieval step.
Morelli, John N; Ai, Fei; Runge, Val M; Zhang, Wei; Li, Xiaoming; Schmitt, Peter; McNeal, Gary; Michaely, Henrick J; Schoenberg, Stefan O; Miller, Matthew; Gerdes, Clint M; Sincleair, Spencer T; Spratt, Heidi; Attenberger, Ulrike I
2012-09-01
To establish the minimum dose required for detection of renal artery stenosis using high temporal resolution, contrast enhanced MR angiography (MRA) in a porcine model. Surgically created renal artery stenoses were imaged with 3 Tesla MR and digital subtraction angiography (DSA) in 12 swine in this IACUC approved protocol. Gadobutrol was injected intravenously at doses of 0.5, 1, 2, and 4 mL for time-resolved MRA (1.5 × 1.5 mm(2) spatial resolution). Region of interest analysis was performed together with stenosis assessment and qualitative evaluation by two blinded readers. Mean signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were statistically significantly less with the 0.5-mL protocol (P < 0.001). There were no statistically significant differences among the other evaluated doses. Both readers found 10/12 cases with the 0.5-mL protocol to be of inadequate diagnostic quality (κ = 1.0). All other scans were found to be adequate for diagnosis. Accuracies in distinguishing between mild/insignificant (<50%) and higher grade stenoses (>50%) were comparable among the higher-dose protocols (sensitivities 73-93%, specificities 62-100%). Renal artery stenosis can be assessed with very low doses (~0.025 mmol/kg bodyweight) of a high concentration, high relaxivity gadolinium chelate formulation in a swine model, results which are promising with respect to limiting exposure to gadolinium based contrast agents. Copyright © 2012 Wiley Periodicals, Inc.
Protocolized fluid therapy in brain-dead donors: The multi-center randomized MOnIToR trial
Al-Khafaji, Ali; Elder, Michele; Lebovitz, Daniel J; Murugan, Raghavan; Souter, Michael; Stuart, Susan; Wahed, Abdus S.; Keebler, Ben; Dils, Dorrie; Mitchell, Stephanie; Shutterly, Kurt; Wilkerson, Dawn; Pearse, Rupert; Kellum, John A
2015-01-01
BACKGROUND Critical shortages of organs for transplantation jeopardize many lives. Observational data suggest that better fluid management for deceased organ donors could increase organ recovery. We conducted the first large multi-center randomized trial in brain-dead donors to determine whether protocolized fluid therapy increases organs transplanted. METHODS We randomly assigned donors to either protocolized or usual care in eight organ procurement organizations. A “protocol-guided fluid therapy” algorithm targeting cardiac index, mean arterial pressure and pulse pressure variation was used. Our primary outcome was the number of organs transplanted per donor and our primary analysis was intention-to-treat. Secondary analyses included: 1) modified intention-to-treat where only subjects able to receive the intervention were included, and 2) twelve-month survival in transplant recipients. The study was stopped early. RESULTS We enrolled 556 donors; 279 protocolized care, 277 usual care. Groups had similar characteristics at baseline. The study protocol could be implemented in 76% of subjects randomized to the intervention. There was no significant difference in mean number of organs transplanted per donor: 3.39 organs per donor, (95%CI: 3.14-3.63) with protocolized care, compared to usual care 3.29 (95%CI: 3.04-3.54) (mean difference, 0.1, 95%CI: -0.25 to 0.45; p=0.56). In modified intention-to-treat analysis the mean number of organs increased (3.52 organs per donor, 95%CI: 3.23-3.8) but was not statistically significant (mean difference, 0.23, 95%CI: -0.15-0.61; p=0.23). Among the 1430 recipients of organs from study subjects, with data available, 56 deaths (7.8%) occurred in the protocolized care arm and 56 (7.9%) in the usual care arm in the first year (Hazard Ratio: 0.97, p=0.86). CONCLUSIONS In brain-dead organ donors, protocol-guided fluid therapy compared to usual care may not increase the number of organs transplanted per donor. PMID:25583616
Hwang, Inpyeong; Cho, Jeong Yeon; Kim, Sang Youn; Oh, Seung-June; Ku, Ja Hyeon; Lee, Joongyup; Kim, Seung Hyup
2015-12-01
The aim of the present study was to investigate the feasibility and image quality of excretory CT urography performed using low iodine-concentration contrast media and low tube voltage. This prospective study enrolled 63 patients who undergoing CT urography. The subjects were randomized into two groups of an excretory phase CT urography protocol and received either 240 mg I/mL of contrast media and 80 kVp of tube voltage (low-concentration protocol, n=32) or 350 mg I/mL and 120 kVp (conventional protocol, n=31). Two readers qualitatively evaluated images for sharpness of the urinary tract, image noise, streak artifact and overall diagnostic acceptability. The mean attenuation, signal-to-noise ratio, contrast-to-noise ratio and figure of merit were measured in the urinary tract. The non-inferiority test assessed the diagnostic acceptability between the two protocol groups. The low-concentration protocol showed a significantly lower effective radiation dose (3.44 vs. 5.70 mSv, P<.001). The diagnostic acceptability was significantly lower in the low-concentration protocol with iterative reconstruction algorithm than in the conventional protocol (4.06±0.45 vs. 4.50±0.37, P<.001), however, all subjects showed at least more than standard diagnostic acceptability and the difference resided in the predefined non-inferiority margin. The signal-to-noise ratio, contrast-to-noise ratio and figure of merit were significantly higher in the low-concentration protocol along the entire urinary tract (P<.001). CT urography using 240 mg I/mL iodine contrast media, 80 kVp tube voltage and an iterative reconstruction algorithm is beneficial to reduce radiation dose and iodine load, and its objective image quality and subjective diagnostic acceptability is not inferior to that of conventional CT urography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
A Smart Collaborative Routing Protocol for Reliable Data Diffusion in IoT Scenarios.
Ai, Zheng-Yang; Zhou, Yu-Tong; Song, Fei
2018-06-13
It is knotty for current routing protocols to meet the needs of reliable data diffusion during the Internet of Things (IoT) deployments. Due to the random placement, limited resources and unattended features of existing sensor nodes, the wireless transmissions are easily exposed to unauthorized users, which becomes a vulnerable area for various malicious attacks, such as wormhole and Sybil attacks. However, the scheme based on geographic location is a suitable candidate to defend against them. This paper is inspired to propose a smart collaborative routing protocol, Geographic energy aware routing and Inspecting Node (GIN), for guaranteeing the reliability of data exchanging. The proposed protocol integrates the directed diffusion routing, Greedy Perimeter Stateless Routing (GPSR), and the inspecting node mechanism. We first discuss current wireless routing protocols from three diverse perspectives (improving transmission rate, shortening transmission range and reducing transmission consumption). Then, the details of GIN, including the model establishment and implementation processes, are presented by means of the theoretical analysis. Through leveraging the game theory, the inspecting node is elected to monitor the network behaviors. Thirdly, we evaluate the network performances, in terms of transmission delay, packet loss ratio, and throughput, between GIN and three traditional schemes (i.e., Flooding, GPSR, and GEAR). The simulation results illustrate that the proposed protocol is able to outperform the others.
Verification of the Jenkins and FIA sapling biomass equations for hardwood species in Maine
Andrew S. Nelson; Aaron R. Weiskittel; Robert G. Wagner; Michael R. Saunders
2012-01-01
In 2009, the Forest Inventory and Analysis Program (FIA) updated its biomass estimation protocols by switching to the component ratio method to estimate biomass of medium and large trees. Additionally, FIA switched from using regional equations to the current FIA aboveground sapling biomass equations that predict woody sapling (2.5 to 12.4 cm d.b.h.) biomass using the...
Latency correction of event-related potentials between different experimental protocols
NASA Astrophysics Data System (ADS)
Iturrate, I.; Chavarriaga, R.; Montesano, L.; Minguez, J.; Millán, JdR
2014-06-01
Objective. A fundamental issue in EEG event-related potentials (ERPs) studies is the amount of data required to have an accurate ERP model. This also impacts the time required to train a classifier for a brain-computer interface (BCI). This issue is mainly due to the poor signal-to-noise ratio and the large fluctuations of the EEG caused by several sources of variability. One of these sources is directly related to the experimental protocol or application designed, and may affect the amplitude or latency of ERPs. This usually prevents BCI classifiers from generalizing among different experimental protocols. In this paper, we analyze the effect of the amplitude and the latency variations among different experimental protocols based on the same type of ERP. Approach. We present a method to analyze and compensate for the latency variations in BCI applications. The algorithm has been tested on two widely used ERPs (P300 and observation error potentials), in three experimental protocols in each case. We report the ERP analysis and single-trial classification. Main results. The results obtained show that the designed experimental protocols significantly affect the latency of the recorded potentials but not the amplitudes. Significance. These results show how the use of latency-corrected data can be used to generalize the BCIs, reducing the calibration time when facing a new experimental protocol.
Saleem, Kashif; Derhab, Abdelouahid; Orgun, Mehmet A; Al-Muhtadi, Jalal; Rodrigues, Joel J P C; Khalil, Mohammed Sayim; Ali Ahmed, Adel
2016-03-31
The deployment of intelligent remote surveillance systems depends on wireless sensor networks (WSNs) composed of various miniature resource-constrained wireless sensor nodes. The development of routing protocols for WSNs is a major challenge because of their severe resource constraints, ad hoc topology and dynamic nature. Among those proposed routing protocols, the biology-inspired self-organized secure autonomous routing protocol (BIOSARP) involves an artificial immune system (AIS) that requires a certain amount of time to build up knowledge of neighboring nodes. The AIS algorithm uses this knowledge to distinguish between self and non-self neighboring nodes. The knowledge-building phase is a critical period in the WSN lifespan and requires active security measures. This paper proposes an enhanced BIOSARP (E-BIOSARP) that incorporates a random key encryption mechanism in a cost-effective manner to provide active security measures in WSNs. A detailed description of E-BIOSARP is presented, followed by an extensive security and performance analysis to demonstrate its efficiency. A scenario with E-BIOSARP is implemented in network simulator 2 (ns-2) and is populated with malicious nodes for analysis. Furthermore, E-BIOSARP is compared with state-of-the-art secure routing protocols in terms of processing time, delivery ratio, energy consumption, and packet overhead. The findings show that the proposed mechanism can efficiently protect WSNs from selective forwarding, brute-force or exhaustive key search, spoofing, eavesdropping, replaying or altering of routing information, cloning, acknowledgment spoofing, HELLO flood attacks, and Sybil attacks.
Saleem, Kashif; Derhab, Abdelouahid; Orgun, Mehmet A.; Al-Muhtadi, Jalal; Rodrigues, Joel J. P. C.; Khalil, Mohammed Sayim; Ali Ahmed, Adel
2016-01-01
The deployment of intelligent remote surveillance systems depends on wireless sensor networks (WSNs) composed of various miniature resource-constrained wireless sensor nodes. The development of routing protocols for WSNs is a major challenge because of their severe resource constraints, ad hoc topology and dynamic nature. Among those proposed routing protocols, the biology-inspired self-organized secure autonomous routing protocol (BIOSARP) involves an artificial immune system (AIS) that requires a certain amount of time to build up knowledge of neighboring nodes. The AIS algorithm uses this knowledge to distinguish between self and non-self neighboring nodes. The knowledge-building phase is a critical period in the WSN lifespan and requires active security measures. This paper proposes an enhanced BIOSARP (E-BIOSARP) that incorporates a random key encryption mechanism in a cost-effective manner to provide active security measures in WSNs. A detailed description of E-BIOSARP is presented, followed by an extensive security and performance analysis to demonstrate its efficiency. A scenario with E-BIOSARP is implemented in network simulator 2 (ns-2) and is populated with malicious nodes for analysis. Furthermore, E-BIOSARP is compared with state-of-the-art secure routing protocols in terms of processing time, delivery ratio, energy consumption, and packet overhead. The findings show that the proposed mechanism can efficiently protect WSNs from selective forwarding, brute-force or exhaustive key search, spoofing, eavesdropping, replaying or altering of routing information, cloning, acknowledgment spoofing, HELLO flood attacks, and Sybil attacks. PMID:27043572
Boudreau, Mathieu; Pike, G Bruce
2018-05-07
To develop and validate a regularization approach of optimizing B 1 insensitivity of the quantitative magnetization transfer (qMT) pool-size ratio (F). An expression describing the impact of B 1 inaccuracies on qMT fitting parameters was derived using a sensitivity analysis. To simultaneously optimize for robustness against noise and B 1 inaccuracies, the optimization condition was defined as the Cramér-Rao lower bound (CRLB) regularized by the B 1 -sensitivity expression for the parameter of interest (F). The qMT protocols were iteratively optimized from an initial search space, with and without B 1 regularization. Three 10-point qMT protocols (Uniform, CRLB, CRLB+B 1 regularization) were compared using Monte Carlo simulations for a wide range of conditions (e.g., SNR, B 1 inaccuracies, tissues). The B 1 -regularized CRLB optimization protocol resulted in the best robustness of F against B 1 errors, for a wide range of SNR and for both white matter and gray matter tissues. For SNR = 100, this protocol resulted in errors of less than 1% in mean F values for B 1 errors ranging between -10 and 20%, the range of B 1 values typically observed in vivo in the human head at field strengths of 3 T and less. Both CRLB-optimized protocols resulted in the lowest σ F values for all SNRs and did not increase in the presence of B 1 inaccuracies. This work demonstrates a regularized optimization approach for improving the robustness of auxiliary measurements (e.g., B 1 ) sensitivity of qMT parameters, particularly the pool-size ratio (F). Predicting substantially less B 1 sensitivity using protocols optimized with this method, B 1 mapping could even be omitted for qMT studies primarily interested in F. © 2018 International Society for Magnetic Resonance in Medicine.
Implementation of AICAR analysis by GC-C-IRMS for anti-doping purposes.
Buisson, C; Frelat, C; Mongongu, C; Martinat, N; Audran, M
2017-11-01
AICAR (5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside), is a naturally occurring substance which is part to the World Anti-Doping Agency (WADA) Prohibited List. It is claimed to improve physical performance when administered as a supplement. As for other endogenous compounds such as steroids, the gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) analysis remains an efficient tool to differentiate endogenous substances from exogenous ones. A protocol was described in the literature for the analysis of AICAR by GC-C-IRMS. The aim of the present study was to implement this protocol in our laboratory and to propose solutions to avoid the difficulties encountered. The first point discussed in this study is the derivatization step. Due to the structure of the AICAR molecule, conventional derivatization for GC-C-IRMS such as acetylation could not be applied and silylation was preferred. The improvement of the derivatives stability was achieved thanks to several derivatization conditions tested. This adjustment led to a reproducible derivatization pattern with the 3-TMS form as major derivative product. The second point discussed in this study is the diminution of extracts' background noise. Indeed, the implementation of the published protocol was not easy due to high performance liquid chromatography (HPLC) problems encountered when concentrated urine was injected into our system. Also, too many interferences in the endogenous reference compound fractions were observed. The addition of both a wash step before the HPLC purification and a HPLC purification step for the endogenous reference compound (ERC) fraction allowed us to increase the robustness of the method. This study presents the modified protocol compared to the original protocol as well as the evaluation of the whole method performances. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Advertisement-Based Energy Efficient Medium Access Protocols for Wireless Sensor Networks
NASA Astrophysics Data System (ADS)
Ray, Surjya Sarathi
One of the main challenges that prevents the large-scale deployment of Wireless Sensor Networks (WSNs) is providing the applications with the required quality of service (QoS) given the sensor nodes' limited energy supplies. WSNs are an important tool in supporting applications ranging from environmental and industrial monitoring, to battlefield surveillance and traffic control, among others. Most of these applications require sensors to function for long periods of time without human intervention and without battery replacement. Therefore, energy conservation is one of the main goals for protocols for WSNs. Energy conservation can be performed in different layers of the protocol stack. In particular, as the medium access control (MAC) layer can access and control the radio directly, large energy savings is possible through intelligent MAC protocol design. To maximize the network lifetime, MAC protocols for WSNs aim to minimize idle listening of the sensor nodes, packet collisions, and overhearing. Several approaches such as duty cycling and low power listening have been proposed at the MAC layer to achieve energy efficiency. In this thesis, I explore the possibility of further energy savings through the advertisement of data packets in the MAC layer. In the first part of my research, I propose Advertisement-MAC or ADV-MAC, a new MAC protocol for WSNs that utilizes the concept of advertising for data contention. This technique lets nodes listen dynamically to any desired transmission and sleep during transmissions not of interest. This minimizes the energy lost in idle listening and overhearing while maintaining an adaptive duty cycle to handle variable loads. Additionally, ADV-MAC enables energy efficient MAC-level multicasting. An analytical model for the packet delivery ratio and the energy consumption of the protocol is also proposed. The analytical model is verified with simulations and is used to choose an optimal value of the advertisement period. Simulations show that the optimized ADV-MAC provides substantial energy gains (50% to 70% less than other MAC protocols for WSNs such as T-MAC and S-MAC for the scenarios investigated) while faring as well as T-MAC in terms of packet delivery ratio and latency. Although ADV-MAC provides substantial energy gains over S-MAC and T-MAC, it is not optimal in terms of energy savings because contention is done twice -- once in the Advertisement Period and once in the Data Period. In the next part of my research, the second contention in the Data Period is eliminated and the advantages of contention-based and TDMA-based protocols are combined to form Advertisement based Time-division Multiple Access (ATMA), a distributed TDMA-based MAC protocol for WSNs. ATMA utilizes the bursty nature of the traffic to prevent energy waste through advertisements and reservations for data slots. Extensive simulations and qualitative analysis show that with bursty traffic, ATMA outperforms contention-based protocols (S-MAC, T-MAC and ADV-MAC), a TDMA based protocol (TRAMA) and hybrid protocols (Z-MAC and IEEE 802.15.4). ATMA provides energy reductions of up to 80%, while providing the best packet delivery ratio (close to 100%) and latency among all the investigated protocols. Simulations alone cannot reflect many of the challenges faced by real implementations of MAC protocols, such as clock-drift, synchronization, imperfect physical layers, and irregular interference from other transmissions. Such issues may cripple a protocol that otherwise performs very well in software simulations. Hence, to validate my research, I conclude with a hardware implementation of the ATMA protocol on SORA (Software Radio), developed by Microsoft Research Asia. SORA is a reprogrammable Software Defined Radio (SDR) platform that satisfies the throughput and timing requirements of modern wireless protocols while utilizing the rich general purpose PC development environment. Experimental results obtained from the hardware implementation of ATMA closely mirror the simulation results obtained for a single hop network with 4 nodes.
Saade, Charbel; El-Merhi, Fadi; El-Achkar, Bassam; Kerek, Racha; Vogl, Thomas J; Maroun, Gilbert Georges; Jamjoom, Lamia; Al-Mohiy, Hussain; Naffaa, Lena
Caudocranial scan direction and contrast injection timing based on measured patient vessel dynamics can significantly improve arterial and aneurysmal opacification and reduce both contrast and radiation dose in the assessment of thoracic aortic aneurysms (TAA) using helical thoracic computed tomography angiography (CTA). To investigate opacification of the thoracic aorta and TAA using a caudocranial scan direction and a patient-specific contrast protocol. Thoracic aortic CTA was performed in 160 consecutive patients with suspected TAA using a 256-slice computed tomography scanner and a dual barrel contrast injector. Patients were subjected in equal numbers to one of two contrast protocols. Patient age and sex were equally distributed across both groups. Protocol A, the department's standard protocol, consisted of a craniocaudal scan direction with 100 mL of contrast, intravenously injected at a flow rate of 4.5 mL/s. Protocol B involved a caudocranial scan direction and a novel contrast formula based on patient cardiovascular dynamics, followed by 100 mL of saline at 4.5 mL/s. Each scan acquisition comprised of 120 kVp, 200 mA with modulation, temporal resolution 0.27 seconds, and pitch 0.889:1. The dose length product was measured between each protocol and data generated were compared using Mann-Whitney U nonparametric statistics. Receiver operating characteristic analysis, visual grading characteristic (VGC), and κ analyses were performed. Mean opacification in the thoracic aorta and aneurysm measured was 24 % and 55%, respectively. The mean contrast volume was significantly lower in protocol B (73 ± 10 mL) compared with A (100 ± 1 mL) (P<0.001). The contrast-to-noise ratio demonstrated significant differences between the protocols (protocol A, 18.2 ± 12.9; protocol B, 29.7 ± 0.61; P < 0.003). Mean effective dose in protocol B (2.6 ± 0.4 mSv) was reduced by 19% compared with A (3.2 ± 0.8 mSv) (P < 0.004). Aneurysmal detectability demonstrated significant increases by receiver operating characteristic and visual grading characteristic analysis for protocol B compared with A (P < 0.02), and reader agreement increased from poor to excellent. Significant increase in the visualization of TAAs following a caudocranial scan direction during helical thoracic CTA can be achieved using low-contrast volume based on patient-specific contrast formula.
Featherall, Joseph; Brigati, David P; Faour, Mhamad; Messner, William; Higuera, Carlos A
2018-06-01
Standardized care pathways are evidence-based algorithms for optimizing an episode of care. Despite the theoretical promise of care pathways, there is an inconsistent literature demonstrating improvements in patient care. The authors hypothesized that implementing a care pathway, across 11 hospitals, would decrease hospital length of stay (LOS), decrease postoperative complications at 90 days, and increase discharges to home. A multidisciplinary team developed an evidence-based care pathway for total hip arthroplasty (THA) perioperative care. All patients receiving THA in 2013 (pre-protocol, historical control), 2014 (transition), and 2015 (full protocol implementation) were included in the analysis. Multivariable regression assessed the relationship of the care pathway to 90-day postoperative complications, LOS, and discharge disposition. Cost savings were estimated using previously published postarthroplasty episode and per diem hospital costs. A total of 6090 primary THAs were conducted during the study period. After adjusting for the covariates, the full protocol implementation was associated with a decrease in LOS (mean ratio, 0.747; 95% confidence interval [CI; 0.727, 0.767]) and an increase in discharges to home (odds ratio, 2.079; 95% CI [1.762, 2.456]). The full protocol implementation was not associated with a change in 90-day complications (odds ratio, 1.023; 95% CI [0.841, 1.245]). Payer-perspective-calculated theoretical cost savings, including both index admission and postdischarge costs, were $2533 per patient. The THA care pathway implementation was successful in reducing LOS and increasing discharges to home. The care pathway was not associated with a change in 90-day complications; further targeted interventions in this area are needed. Despite care standardization efforts, high-volume hospitals and surgeons had higher performance. Extrapolation of theoretical cost savings indicates that widespread THA care pathway adoption could lead to national healthcare savings of $1.2 billion annually. Copyright © 2018 Elsevier Inc. All rights reserved.
Bonny, Jean Marie; Boespflug-Tanguly, Odile; Zanca, Michel; Renou, Jean Pierre
2003-03-01
A solution for discrete multi-exponential analysis of T(2) relaxation decay curves obtained in current multi-echo imaging protocol conditions is described. We propose a preprocessing step to improve the signal-to-noise ratio and thus lower the signal-to-noise ratio threshold from which a high percentage of true multi-exponential detection is detected. It consists of a multispectral nonlinear edge-preserving filter that takes into account the signal-dependent Rician distribution of noise affecting magnitude MR images. Discrete multi-exponential decomposition, which requires no a priori knowledge, is performed by a non-linear least-squares procedure initialized with estimates obtained from a total least-squares linear prediction algorithm. This approach was validated and optimized experimentally on simulated data sets of normal human brains.
NASA Astrophysics Data System (ADS)
Wu, Cheng; Huang, X. H. Hilda; Ng, Wai Man; Griffith, Stephen M.; Zhen Yu, Jian
2016-09-01
Organic carbon (OC) and elemental carbon (EC) are operationally defined by analytical methods. As a result, OC and EC measurements are protocol dependent, leading to uncertainties in their quantification. In this study, more than 1300 Hong Kong samples were analyzed using both National Institute for Occupational Safety and Health (NIOSH) thermal optical transmittance (TOT) and Interagency Monitoring of Protected Visual Environment (IMPROVE) thermal optical reflectance (TOR) protocols to explore the cause of EC disagreement between the two protocols. EC discrepancy mainly (83 %) arises from a difference in peak inert mode temperature, which determines the allocation of OC4NSH, while the rest (17 %) is attributed to a difference in the optical method (transmittance vs. reflectance) applied for the charring correction. Evidence shows that the magnitude of the EC discrepancy is positively correlated with the intensity of the biomass burning signal, whereby biomass burning increases the fraction of OC4NSH and widens the disagreement in the inter-protocol EC determination. It is also found that the EC discrepancy is positively correlated with the abundance of metal oxide in the samples. Two approaches (M1 and M2) that translate NIOSH TOT OC and EC data into IMPROVE TOR OC and EC data are proposed. M1 uses direct relationship between ECNSH_TOT and ECIMP_TOR for reconstruction: M1 : ECIMP_TOR = a × ECNSH_TOT + b; while M2 deconstructs ECIMP_TOR into several terms based on analysis principles and applies regression only on the unknown terms: M2 : ECIMP_TOR = AECNSH + OC4NSH - (a × PCNSH_TOR + b), where AECNSH, apparent EC by the NIOSH protocol, is the carbon that evolves in the He-O2 analysis stage, OC4NSH is the carbon that evolves at the fourth temperature step of the pure helium analysis stage of NIOSH, and PCNSH_TOR is the pyrolyzed carbon as determined by the NIOSH protocol. The implementation of M1 to all urban site data (without considering seasonal specificity) yields the following equation: M1(urban data) : ECIMP_TOR = 2.20 × ECNSH_TOT - 0.05. While both M1 and M2 are acceptable, M2 with site-specific parameters provides the best reconstruction performance. Secondary OC (SOC) estimation using OC and EC by the two protocols is compared. An analysis of the usability of reconstructed ECIMP_TOR and OCIMP_TOR suggests that the reconstructed values are not suitable for SOC estimation due to the poor reconstruction of the OC / EC ratio.
Krzyzanowska, Agnieszka; Lippolis, Giuseppe; Helczynski, Leszek; Anand, Aseem; Peltola, Mari; Pettersson, Kim; Lilja, Hans; Bjartell, Anders
2016-05-01
Androgen receptor (AR) and prostate-specific antigen (PSA) are expressed in the prostate and are involved in prostate cancer (PCa). The aim of this study was to develop reliable protocols for reproducible quantification of AR and PSA in benign and malignant prostate tissue using time-resolved fluorescence (TRF) imaging techniques. AR and PSA were detected with TRF in tissue microarrays from 91 PCa patients. p63/ alpha-methylacyl-CoA racemase (AMACR) staining on consecutive sections was used to categorize tissue areas as benign or cancerous. Automated image analysis was used to quantify staining intensity. AR intensity was significantly higher in AMACR+ and lower in AMACR- cancer areas as compared with benign epithelium. The PSA intensity was significantly lower in cancer areas, particularly in AMACR- glands. The AR/PSA ratio varied significantly in the AMACR+ tumor cells as compared with benign glands. There was a trend of more rapid disease progression in patients with higher AR/PSA ratios in the AMACR- areas. This study demonstrates the feasibility of developing reproducible protocols for TRF imaging and automated image analysis to study the expression of AR and PSA in benign and malignant prostate. It also highlighted the differences in AR and PSA protein expression within AMACR- and AMACR+ cancer regions. © 2016 The Histochemical Society.
Spinner, Georg; Wyss, Michael; Erni, Stefan; Ettlin, Dominik A; Nanz, Daniel; Ulbrich, Erika J; Gallo, Luigi M; Andreisek, Gustav
2016-01-01
Objectives: To quantitatively and qualitatively compare MRI of the temporomandibular joint (TMJ) using an optimized high-resolution protocol at 3.0 T and a clinical standard protocol at 1.5 T. Methods: A phantom and 12 asymptomatic volunteers were MR imaged using a 2-channel surface coil (standard TMJ coil) at 1.5 and 3.0 T (Philips Achieva and Philips Ingenia, respectively; Philips Healthcare, Best, Netherlands). Imaging protocol consisted of coronal and oblique sagittal proton density-weighted turbo spin echo sequences. For quantitative evaluation, a spherical phantom was imaged. Signal-to-noise ratio (SNR) maps were calculated on a voxelwise basis. For qualitative evaluation, all volunteers underwent MRI of the TMJ with the jaw in closed position. Two readers independently assessed visibility and delineation of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale. Quantitative and qualitative measurements were compared between field strengths. Results: The quantitative analysis showed similar SNR for the high-resolution protocol at 3.0 T compared with the clinical protocol at 1.5 T. The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including the TMJ disc and pterygoid muscle as well as better overall image quality at 3.0 T than at 1.5 T. Conclusions: The presented results indicate that expected gains in SNR at 3.0 T can be used to increase the spatial resolution when imaging the TMJ, which translates into increased visibility and delineation of anatomical structures of the TMJ. Therefore, imaging at 3.0 T should be preferred over 1.5 T for imaging the TMJ. PMID:26371077
Manoliu, Andrei; Spinner, Georg; Wyss, Michael; Erni, Stefan; Ettlin, Dominik A; Nanz, Daniel; Ulbrich, Erika J; Gallo, Luigi M; Andreisek, Gustav
2016-01-01
To quantitatively and qualitatively compare MRI of the temporomandibular joint (TMJ) using an optimized high-resolution protocol at 3.0 T and a clinical standard protocol at 1.5 T. A phantom and 12 asymptomatic volunteers were MR imaged using a 2-channel surface coil (standard TMJ coil) at 1.5 and 3.0 T (Philips Achieva and Philips Ingenia, respectively; Philips Healthcare, Best, Netherlands). Imaging protocol consisted of coronal and oblique sagittal proton density-weighted turbo spin echo sequences. For quantitative evaluation, a spherical phantom was imaged. Signal-to-noise ratio (SNR) maps were calculated on a voxelwise basis. For qualitative evaluation, all volunteers underwent MRI of the TMJ with the jaw in closed position. Two readers independently assessed visibility and delineation of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale. Quantitative and qualitative measurements were compared between field strengths. The quantitative analysis showed similar SNR for the high-resolution protocol at 3.0 T compared with the clinical protocol at 1.5 T. The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including the TMJ disc and pterygoid muscle as well as better overall image quality at 3.0 T than at 1.5 T. The presented results indicate that expected gains in SNR at 3.0 T can be used to increase the spatial resolution when imaging the TMJ, which translates into increased visibility and delineation of anatomical structures of the TMJ. Therefore, imaging at 3.0 T should be preferred over 1.5 T for imaging the TMJ.
Iyama, Yuji; Nakaura, Takeshi; Yokoyama, Koichi; Kidoh, Masafumi; Harada, Kazunori; Oda, Seitaro; Tokuyasu, Shinichi; Yamashita, Yasuyuki
This study aimed to evaluate the feasibility of a low contrast, low-radiation dose protocol of 80-peak kilovoltage (kVp) with prospective electrocardiography-gated cardiac computed tomography (CT) using knowledge-based iterative model reconstruction (IMR). Thirty patients underwent an 80-kVp prospective electrocardiography-gated cardiac CT with low-contrast agent (222-mg iodine per kilogram of body weight) dose. We also enrolled 30 consecutive patients who were scanned with a 120-kVp cardiac CT with filtered back projection using the standard contrast agent dose (370-mg iodine per kilogram of body weight) as a historical control group. We evaluated the radiation dose for the 2 groups. The 80-kVp images were reconstructed with filtered back projection (protocol A), hybrid iterative reconstruction (HIR, protocol B), and IMR (protocol C). We compared CT numbers, image noise, and contrast-to-noise ratio among 120-kVp protocol, protocol A, protocol B, and protocol C. In addition, we compared the noise reduction rate between HIR and IMR. Two independent readers compared image contrast, image noise, image sharpness, unfamiliar image texture, and overall image quality among the 4 protocols. The estimated effective dose (ED) of the 80-kVp protocol was 74% lower than that of the 120-kVp protocol (1.4 vs 5.4 mSv). The contrast-to-noise ratio of protocol C was significantly higher than that of protocol A. The noise reduction rate of IMR was significantly higher than that of HIR (P < 0.01). There was no significant difference in almost all qualitative image quality between 120-kVp protocol and protocol C except for image contrast. A 80-kVp protocol with IMR yields higher image quality with 74% decreased radiation dose and 40% decreased contrast agent dose as compared with a 120-kVp protocol, while decreasing more image noise compared with the 80-kVp protocol with HIR.
Feasibility of satellite quantum key distribution
NASA Astrophysics Data System (ADS)
Bonato, C.; Tomaello, A.; Da Deppo, V.; Naletto, G.; Villoresi, P.
2009-04-01
In this paper, we present a novel analysis of the feasibility of quantum key distribution between a LEO satellite and a ground station. First of all, we study signal propagation through a turbulent atmosphere for uplinks and downlinks, discussing the contribution of beam spreading and beam wandering. Then we introduce a model for the background noise of the channel during night-time and day-time, calculating the signal-to-noise ratio for different configurations. We also discuss the expected error-rate due to imperfect polarization compensation in the channel. Finally, we calculate the expected key generation rate of a secure key for different configurations (uplink, downlink) and for different protocols (BB84 with and without decoy states, entanglement-based Ekert91 protocol).
Hsiao, K M; Lin, H M; Pan, H; Li, T C; Chen, S S; Jou, S B; Chiu, Y L; Wu, M F; Lin, C C; Li, S Y
1999-01-01
Myotonic dystrophy (DM) is caused by a CTG trinucleotide expansion mutation at exon 15 of the myotonic dystrophy protein kinase gene. The clinical severity of this disease correlates with the length of the CTG trinucleotide repeats. Determination of the CTG repeat length has been primarily relied on by Southern blot analysis of restriction enzyme-digested genomic DNA. The development of PCR-based Southern blotting methodology provides a much more sensitive and simpler protocol for DM diagnosis. However, the quality of the template and the high (G+C) ratio of the amplified region hamper the use of PCR on the diagnosis of DM. A modified PCR protocol to amplify different lengths of CTG repeat region using various concentrations of 7deaza-dGTP has been reported (1). Here we describe a procedure including sample collection, DNA purification, and PCR analysis of CTG repeat length without using 7-deaza-dGTP. This protocol is very sensitive and convenient because only a small number of nucleate cells are needed for detection of CTG expansion. Therefore, it could be very useful in clinical and prenatal diagnosis as well as in prevalence study of DM.
Znati, Sami A.; Chedid, Nicholas; Miao, Houxun; Chen, Lei; Bennett, Eric E.; Wen, Han
2016-01-01
Filling high-aspect-ratio trenches with gold is a frequent requirement in the fabrication of x-ray optics as well as micro-electronic components and other fabrication processes. Conformal electrodeposition of gold in sub-micron-width silicon trenches with an aspect ratio greater than 35 over a grating area of several square centimeters is challenging and has not been described in the literature previously. A comparison of pulsed plating and constant current plating led to a gold electroplating protocol that reliably filled trenches for such structures. PMID:27042384
Protocolized fluid therapy in brain-dead donors: the multicenter randomized MOnIToR trial.
Al-Khafaji, Ali; Elder, Michele; Lebovitz, Daniel J; Murugan, Raghavan; Souter, Michael; Stuart, Susan; Wahed, Abdus S; Keebler, Ben; Dils, Dorrie; Mitchell, Stephanie; Shutterly, Kurt; Wilkerson, Dawn; Pearse, Rupert; Kellum, John A
2015-03-01
Critical shortages of organs for transplantation jeopardize many lives. Observational data suggest that better fluid management for deceased organ donors could increase organ recovery. We conducted the first large multicenter randomized trial in brain-dead donors to determine whether protocolized fluid therapy increases the number of organs transplanted. We randomly assigned donors to either protocolized or usual care in eight organ procurement organizations. A "protocol-guided fluid therapy" algorithm targeting the cardiac index, mean arterial pressure and pulse pressure variation was used. Our primary outcome was the number of organs transplanted per donor, and our primary analysis was intention to treat. Secondary analyses included: (1) modified intention to treat where only subjects able to receive the intervention were included and (2) 12-month survival in transplant recipients. The study was stopped early. We enrolled 556 donors: 279 protocolized care and 277 usual care. Groups had similar characteristics at baseline. The study protocol could be implemented in 76 % of subjects randomized to the intervention. There was no significant difference in mean number of organs transplanted per donor: 3.39 organs per donor (95 % CI 3.14-3.63) with protocolized care compared to 3.29 usual care (95 % CI 3.04-3.54; mean difference, 0.1, 95 % CI -0.25 to 0.45; p = 0.56). In modified intention-to-treat analysis the mean number of organs increased (3.52 organs per donor, 95 % CI 3.23-3.8), but not statistically significantly (mean difference, 0.23, 95 % CI -0.15 to 0.61; p = 0.23). Among the 1,430 recipients of organs from study subjects with data available, 56 deaths (7.8 %) occurred in the protocolized care arm and 56 (7.9 %) in the usual care arm in the first year (hazard ratio: 0.97, p = 0.86). In brain-dead organ donors, protocol-guided fluid therapy compared to usual care may not increase the number of organs transplanted per donor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDowell, Lachlan J.; Huang, Shao Hui; Xu, Wei
Purpose: We evaluated the effect of consecutive protocols on overall survival (OS) for cervical esophageal carcinoma (CEC). Methods and Materials: All CEC cases that received definitive radiation therapy (RT) with or without chemotherapy from 1997 to 2013 in 3 consecutive protocols were reviewed. Protocol 1 (P1) consisted of 2-dimensional RT of 54 Gy in 20 fractions with 5-fluorouracil plus either mitomycin C or cisplatin. Protocol 2 (P2) consisted of 3-dimensional conformal RT (3DRT) of ≥60 Gy in 30 fractions plus elective nodal irradiation plus cisplatin. Protocol 3 (P3) consisted of intensity modulated RT (IMRT) of ≥60 Gy in 30 fractions plus elective nodalmore » irradiation plus cisplatin. Multivariable analyses were used to assess the effect of the treatment protocol, RT technique, and RT dose on OS, separately. Results: Of 81 cases (P1, 21; P2, 23; and P3, 37), 34 local (P1, 11 [52%]; P2, 12 [52%]; and P3, 11 [30%]), 16 regional (P1, 6 [29%]); P2, 3 [13%]; and P3, 7 [19%]), and 34 distant (P1, 10 [48%]; P2, 9 [39%]; and P3, 15 [41%]) failures were identified. After adjusting for age (P=.49) and chemotherapy (any vs none; hazard ratio [HR] 0.5, 95% confidence interval [CI] 0.3-0.9; P=.023), multivariable analysis showed P3 had improved OS compared with P1 (HR 0.4, 95% CI 0.2-0.8; P=.005), with a trend shown for benefit compared with P2 (HR 0.6, 95% CI 0.3-1.0; P=.061). OS between P1 and P2 did not differ (P=.29). Analyzed as a continuous variable, higher RT doses were associated with a borderline improved OS (HR 0.97, 95% CI 0.95-1.0; P=.075). IMRT showed improved OS compared with non-IMRT (HR 0.57, 95% CI 0.3-0.8; P=.008). Conclusions: The present retrospective consecutive cohort study showed improved OS with our current protocol (P3; high-dose IMRT with concurrent high-dose cisplatin) compared with historical protocols. The outcomes for patients with CEC remain poor, and novel approaches to improve the therapeutic ratio are warranted.« less
Dewan, Vinay; Lambert, Dennis; Edler, Joshua; Kymes, Steven; Apte, Rajendra S
2012-08-01
Perform a cost-effectiveness analysis of the treatment of diabetic macular edema (DME) with ranibizumab plus prompt or deferred laser versus triamcinolone plus prompt laser. Data for the analysis were drawn from reports of the Diabetic Retinopathy Clinical Research Network (DRCRnet) Protocol I. Computer simulation based on Protocol I data. Analyses were conducted from the payor perspective. Simulated participants assigned characteristics reflecting those seen in Protocol I. Markov models were constructed to replicate Protocol I's 104-week outcomes using a microsimulation approach to estimation. Baseline characteristics, visual acuity (VA), treatments, and complications were based on Protocol I data. Costs were identified by literature search. One-way sensitivity analysis was performed, and the results were validated against Protocol I data. Direct cost of care for 2 years, change in VA from baseline, and incremental cost-effectiveness ratio (ICER) measured as cost per additional letter gained from baseline (Early Treatment of Diabetic Retinopathy Study). For sham plus laser (S+L), ranibizumab plus prompt laser (R+pL), ranibizumab plus deferred laser (R+dL), and triamcinolone plus laser (T+L), effectiveness through 104 weeks was predicted to be 3.46, 7.07, 8.63, and 2.40 letters correct, respectively. The ICER values in terms of dollars per VA letter were $393 (S+L vs. T+L), $5943 (R+pL vs. S+L), and $20 (R+dL vs. R+pL). For pseudophakics, the ICER value for comparison triamcinolone with laser versus ranibizumab with deferred laser was $14 690 per letter gained. No clinically relevant changes in model variables altered outcomes. Internal validation demonstrated good similarity to Protocol I treatment patterns. In treatment of phakic patients with DME, ranibizumab with deferred laser provided an additional 6 letters correct compared with triamcinolone with laser at an additional cost of $19 216 over 2 years. That would indicate that if the gain in VA seen at 2 years is maintained in subsequent years, then the treatment of phakic patients with DME using ranibizumab may meet accepted standards of cost-effectiveness. For pseudophakic patients, first-line treatment with triamcinolone seems to be the most cost-effective option. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Verkest, K R; Fleeman, L M; Rand, J S; Morton, J M
2010-10-01
There is need for simple, inexpensive measures of glucose tolerance, insulin sensitivity, and insulin secretion in dogs. The aim of this study was to estimate the closeness of correlation between fasting and dynamic measures of insulin sensitivity and insulin secretion, the precision of fasting measures, and the agreement between results of standard and simplified glucose tolerance tests in dogs. A retrospective descriptive study using 6 naturally occurring obese and 6 lean dogs was conducted. Data from frequently sampled intravenous glucose tolerance tests (FSIGTTs) in 6 obese and 6 lean client-owned dogs were used to calculate HOMA, QUICKI, fasting glucose and insulin concentrations. Fasting measures of insulin sensitivity and secretion were compared with MINMOD analysis of FSIGTTs using Pearson correlation coefficients, and they were evaluated for precision by the discriminant ratio. Simplified sampling protocols were compared with standard FSIGTTs using Lin's concordance correlation coefficients, limits of agreement, and Pearson correlation coefficients. All fasting measures except fasting plasma glucose concentration were moderately correlated with MINMOD-estimated insulin sensitivity (|r| = 0.62-0.80; P < 0.03), and those that combined fasting insulin and glucose were moderately closely correlated with MINMOD-estimated insulin secretion (r = 0.60-0.79; P < 0.04). HOMA calculated using the nonlinear formulae had the closest estimated correlation (r = 0.77 and 0.74) and the best discrimination for insulin sensitivity and insulin secretion (discriminant ratio 4.4 and 3.4, respectively). Simplified sampling protocols with half as many samples collected over 3 h had close agreement with the full sampling protocol. Fasting measures and simplified intravenous glucose tolerance tests reflect insulin sensitivity and insulin secretion derived from frequently sampled glucose tolerance tests with MINMOD analysis in dogs. Copyright 2010 Elsevier Inc. All rights reserved.
A Geographical Heuristic Routing Protocol for VANETs
Urquiza-Aguiar, Luis; Tripp-Barba, Carolina; Aguilar Igartua, Mónica
2016-01-01
Vehicular ad hoc networks (VANETs) leverage the communication system of Intelligent Transportation Systems (ITS). Recently, Delay-Tolerant Network (DTN) routing protocols have increased their popularity among the research community for being used in non-safety VANET applications and services like traffic reporting. Vehicular DTN protocols use geographical and local information to make forwarding decisions. However, current proposals only consider the selection of the best candidate based on a local-search. In this paper, we propose a generic Geographical Heuristic Routing (GHR) protocol that can be applied to any DTN geographical routing protocol that makes forwarding decisions hop by hop. GHR includes in its operation adaptations simulated annealing and Tabu-search meta-heuristics, which have largely been used to improve local-search results in discrete optimization. We include a complete performance evaluation of GHR in a multi-hop VANET simulation scenario for a reporting service. Our study analyzes all of the meaningful configurations of GHR and offers a statistical analysis of our findings by means of MANOVA tests. Our results indicate that the use of a Tabu list contributes to improving the packet delivery ratio by around 5% to 10%. Moreover, if Tabu is used, then the simulated annealing routing strategy gets a better performance than the selection of the best node used with carry and forwarding (default operation). PMID:27669254
A Geographical Heuristic Routing Protocol for VANETs.
Urquiza-Aguiar, Luis; Tripp-Barba, Carolina; Aguilar Igartua, Mónica
2016-09-23
Vehicular ad hoc networks (VANETs) leverage the communication system of Intelligent Transportation Systems (ITS). Recently, Delay-Tolerant Network (DTN) routing protocols have increased their popularity among the research community for being used in non-safety VANET applications and services like traffic reporting. Vehicular DTN protocols use geographical and local information to make forwarding decisions. However, current proposals only consider the selection of the best candidate based on a local-search. In this paper, we propose a generic Geographical Heuristic Routing (GHR) protocol that can be applied to any DTN geographical routing protocol that makes forwarding decisions hop by hop. GHR includes in its operation adaptations simulated annealing and Tabu-search meta-heuristics, which have largely been used to improve local-search results in discrete optimization. We include a complete performance evaluation of GHR in a multi-hop VANET simulation scenario for a reporting service. Our study analyzes all of the meaningful configurations of GHR and offers a statistical analysis of our findings by means of MANOVA tests. Our results indicate that the use of a Tabu list contributes to improving the packet delivery ratio by around 5% to 10%. Moreover, if Tabu is used, then the simulated annealing routing strategy gets a better performance than the selection of the best node used with carry and forwarding (default operation).
Aristizabal, Paula; Singer, Jenelle; Cooper, Renee; Wells, Kristen J.; Nodora, Jesse; Milburn, Mehrzad; Gahagan, Sheila; Schiff, Deborah E.; Martinez, Maria Elena
2015-01-01
Background Survival rates in pediatric oncology have improved dramatically, in part due to high patient participation in clinical trials. Although racial/ethnic inequalities in clinical trial participation have been reported in adults, pediatric data and studies comparing participation rates by socio-demographic characteristics are scarce. The goal of this study was to assess differences in research protocol participation for childhood cancer by age, sex, race/ethnicity, parental language, cancer type and insurance status. Procedure Data on enrollment in any protocol, biospecimen, or therapeutic protocols were collected and analyzed for newly diagnosed pediatric patients with cancer from 2008–2012 at Rady Children’s Hospital. Results Among the 353 patients included in the analysis, 304 (86.1%) were enrolled in any protocol. Enrollment in biospecimen and therapeutic protocols was 84.2% (261/310) and 81.1% (206/254), respectively. Logistic regression analyses revealed significant enrollment underrepresentation in any protocol for Hispanics compared to Non-Hispanic whites (81% vs. 91%; Odds Ratio [OR], 0.43; 95% Confidence Interval [CI], 0.21–0.90; p=0.021) and among children of Spanish-speaking vs. English-speaking parents (78% vs. 89%; OR, 0.45; 95%CI, 0.23–0.87; p=0.016). Compared to patients aged 0–4 years, significant underrepresentation was also found among patients 15–21 years old (92% vs.72%; OR, 0.21; 95% CI, 0.09–0.48; p<0.001). Similar trends were observed when analyzing enrollment in biospecimen and therapeutic protocols separately. Conclusions There was significant underrepresentation in protocol participation for Hispanics, children of Spanish-speaking parents, and patients ages 15–21. Research is urgently needed to understand barriers to research participation among these groups underrepresented in pediatric oncology clinical trials. PMID:25755225
Distribution of Parvovirus B19 DNA in Blood Compartments and Persistence of Virus in Blood Donors
Lee, Tzong-Hae; Kleinman, Steven H.; Wen, Li; Montalvo, Lani; Todd, Deborah S.; Wright, David J.; Tobler, Leslie H.; Busch, Michael P.
2013-01-01
Introduction Because the receptor for Parvovirus B19 (B19V) is on erythrocytes, we investigated B19V distribution in blood by in-vitro spiking experiments and evaluated viral compartmentalization and persistence in natural infection. Methods Two whole blood protocols (ultracentrifugation and a rapid RBC lysis/removal protocol) were evaluated using quantitative real-time PCR. Whole blood (WB) was spiked with known concentrations of B19V and recovery in various blood fractions was determined. The rapid RBC lysis/removal protocol was then used to compare B19V concentrations in 104 paired whole blood and plasma samples collected longitudinally from 43 B19V infected donors with frozen specimens in the REDS Allogeneic Donor and Recipient Repository (RADAR). Results In B19V spiking experiments, ~one-third of viral DNA was recovered in plasma and two-thirds was loosely bound to erythrocytes. In the IgM positive stage of infection in blood donors when plasma B19V DNA concentrations were > 100 IU/mL, median DNA concentrations were ~30-fold higher in WB than in plasma. In contrast, when IgM was absent and when the B19V DNA concentration was lower, the median whole blood to plasma ratio was ~1. Analysis of longitudinal samples demonstrated persistent detection of B19V in WB but declining ratios of WB/plasma B19V with declining plasma VL levels and loss of IgM-reactivity. Conclusions The WB/plasma B19V DNA ratio varies by stage of infection. Further study is required to determine if this is related to the presence of circulating DNA-positive erythrocytes derived from B19V infected erythroblasts, B19V-specific IgM mediated binding of virus to cells, or other factors. PMID:21303368
NASA Astrophysics Data System (ADS)
Derwent, R. G.; Simmonds, P. G.; Greally, B. R.; O'doherty, S.; McCulloch, A.; Manning, A.; Reimann, S.; Folini, D.; Vollmer, M. K.
The mixing ratios of HCFC-141b (1,1-dichlorofluoroethane) and HCFC-142b (1-chloro-1,1-difluoroethane) have been rising steadily in baseline air at Mace Head, Ireland over the 10-year period from 1994 to 2004. These HCFCs are widely used replacements for the chlorofluorocarbons phased out under the Montreal Protocol and its subsequent amendments. Analysis of the HCFC content of regionally-polluted air arriving at Mace Head from the European continent shows that European emissions reached a peak during 2000-2001 and have declined subsequently, following the phase-out in their usage. European emissions of HCFC-141b have been further constrained by observations at the High-Alpine Jungfraujoch site. The reductions are consistent with the phase-out of HCFC production and use from the year 2001 onwards mandated by European regulations designed to exceed the requirements of the Montreal Protocol.
RNA isolation from mouse pancreas: a ribonuclease-rich tissue.
Azevedo-Pouly, Ana Clara P; Elgamal, Ola A; Schmittgen, Thomas D
2014-08-02
Isolation of high-quality RNA from ribonuclease-rich tissue such as mouse pancreas presents a challenge. As a primary function of the pancreas is to aid in digestion, mouse pancreas may contain as much a 75 mg of ribonuclease. We report modifications of standard phenol/guanidine thiocyanate lysis reagent protocols to isolate RNA from mouse pancreas. Guanidine thiocyanate is a strong protein denaturant and will effectively disrupt the activity of ribonuclease under most conditions. However, critical modifications to standard protocols are necessary to successfully isolate RNA from ribonuclease-rich tissues. Key steps include a high lysis reagent to tissue ratio, removal of undigested tissue prior to phase separation and inclusion of a ribonuclease inhibitor to the RNA solution. Using these and other modifications, we routinely isolate RNA with RNA Integrity Number (RIN) greater than 7. The isolated RNA is of suitable quality for routine gene expression analysis. Adaptation of this protocol to isolate RNA from ribonuclease rich tissues besides the pancreas should be readily achievable.
Gould, Francois D. H.
2014-01-01
Improvements in three-dimensional imaging technologies have renewed interest in the study of functional and ecological morphology. Quantitative approaches to shape analysis are used increasingly to study form-function relationships. These methods are computationally intensive, technically demanding, and time-consuming, which may limit sampling potential. There have been few side-by-side comparisons of the effectiveness of such approaches relative to more traditional analyses using linear measurements and ratios. Morphological variation in the distal femur of mammals has been shown to reflect differences in locomotor modes across clades. Thus I tested whether a geometric morphometric analysis of surface shape was superior to a multivariate analysis of ratios for describing ecomorphological patterns in distal femoral variation. A sample of 164 mammalian specimens from 44 genera was assembled. Each genus was assigned to one of six locomotor categories. The same hypotheses were tested using two methods. Six linear measurements of the distal femur were taken with calipers, from which four ratios were calculated. A 3D model was generated with a laser scanner, and analyzed using three dimensional geometric morphometrics. Locomotor category significantly predicted variation in distal femoral morphology in both analyses. Effect size was larger in the geometric morphometric analysis than in the analysis of ratios. Ordination reveals a similar pattern with arboreal and cursorial taxa as extremes on a continuum of morphologies in both analyses. Discriminant functions calculated from the geometric morphometric analysis were more accurate than those calculated from ratios. Both analysis of ratios and geometric morphometric surface analysis reveal similar, biologically meaningful relationships between distal femoral shape and locomotor mode. The functional signal from the morphology is slightly higher in the geometric morphometric analysis. The practical costs of conducting these sorts of analyses should be weighed against potentially slight increases in power when designing protocols for ecomorphological studies. PMID:24633081
Cox, Helen S; Mbhele, Slindile; Mohess, Neisha; Whitelaw, Andrew; Muller, Odelia; Zemanay, Widaad; Little, Francesca; Azevedo, Virginia; Simpson, John; Boehme, Catharina C; Nicol, Mark P
2014-11-01
Xpert MTB/RIF is approved for use in tuberculosis (TB) and rifampicin-resistance diagnosis. However, data are limited on the impact of Xpert under routine conditions in settings with high TB burden. A pragmatic prospective cluster-randomised trial of Xpert for all individuals with presumptive (symptomatic) TB compared to the routine diagnostic algorithm of sputum microscopy and limited use of culture was conducted in a large TB/HIV primary care clinic. The primary outcome was the proportion of bacteriologically confirmed TB cases not initiating TB treatment by 3 mo after presentation. Secondary outcomes included time to TB treatment and mortality. Unblinded randomisation occurred on a weekly basis. Xpert and smear microscopy were performed on site. Analysis was both by intention to treat (ITT) and per protocol. Between 7 September 2010 and 28 October 2011, 1,985 participants were assigned to the Xpert (n = 982) and routine (n = 1,003) diagnostic algorithms (ITT analysis); 882 received Xpert and 1,063 routine (per protocol analysis). 13% (32/257) of individuals with bacteriologically confirmed TB (smear, culture, or Xpert) did not initiate treatment by 3 mo after presentation in the Xpert arm, compared to 25% (41/167) in the routine arm (ITT analysis, risk ratio 0.51, 95% CI 0.33-0.77, p = 0.0052). The yield of bacteriologically confirmed TB cases among patients with presumptive TB was 17% (167/1,003) with routine diagnosis and 26% (257/982) with Xpert diagnosis (ITT analysis, risk ratio 1.57, 95% CI 1.32-1.87, p<0.001). This difference in diagnosis rates resulted in a higher rate of treatment initiation in the Xpert arm: 23% (229/1,003) and 28% (277/982) in the routine and Xpert arms, respectively (ITT analysis, risk ratio 1.24, 95% CI 1.06-1.44, p = 0.013). Time to treatment initiation was improved overall (ITT analysis, hazard ratio 0.76, 95% CI 0.63-0.92, p = 0.005) and among HIV-infected participants (ITT analysis, hazard ratio 0.67, 95% CI 0.53-0.85, p = 0.001). There was no difference in 6-mo mortality with Xpert versus routine diagnosis. Study limitations included incorrect intervention allocation for a high proportion of participants and that the study was conducted in a single clinic. These data suggest that in this routine primary care setting, use of Xpert to diagnose TB increased the number of individuals with bacteriologically confirmed TB who were treated by 3 mo and reduced time to treatment initiation, particularly among HIV-infected participants. Pan African Clinical Trials Registry PACTR201010000255244. Please see later in the article for the Editors' Summary.
NASA Astrophysics Data System (ADS)
Sztejnberg Goncalves-Carralves, Manuel Leonardo
This dissertation describes a novel Boron Neutron Capture Therapy (BNCT) application for the treatment of human epidermal growth factor receptor type 2 positive (HER2+) breast cancers. The original contribution of the dissertation is the development of the engineering simulation and the feasibility study of the radiation treatment protocol for this novel combination of BNCT and HER2+ breast cancer treatment. This new concept of BNCT, representing a radiation binary targeted treatment, consists of the combination of two approaches never used in a synergism before. This combination may offer realistic hope for relapsed and/or metastasized breast cancers. This treatment assumes that the boronated anti-HER2 monoclonal antibodies (MABs) are administrated to the patient and accumulate preferentially in the tumor. Then the tumor is destroyed when is exposed to neutron irradiation. Since the use of anti-HER2 MABs yields good and promising results, the proposed concept is expected to amplify the known effect and be considered as a possible additional treatment approach to the most severe breast cancers for patients with metastasized cancer for which the current protocol is not successful and for patients refusing to have the standard treatment protocol. This dissertation makes an original contribution with an integral numerical approach and proves feasible the combination of the aforementioned therapy and disease. With these goals, the dissertation describes the theoretical analysis of the proposed concept providing an integral engineering simulation study of the treatment protocol. An extensive analysis of the potential limitations, capabilities and optimization factors are well studied using simplified models, models based on real CT patients' images, cellular models, and Monte Carlo (MCNP5/X) transport codes. One of the outcomes of the integral dosimetry assessment originally developed for the proposed treatment of advanced breast cancers is the implementation of BNCT for HER2+ breast cancers for deep seated tumors using MITRII-FCB facility with an 8 cm diameter beam (port closest-to-tumor position), with boron concentrations in the tumor higher than 32 mug/g, and for a tumor-to-healthy tissue boron concentration ratio of 8:1. The therapeutic ratios for the proposed treatment would be higher than five for skin and adipose tissue and higher than three for tumor surrounding fibroglandular tissue. The microdosimetry study shows potential improvements in the therapeutic ratios based on the expected sub-cellular boron biodistributions. The engineering simulation study of clinical cases shows the advantages of using BNCT for HER+ breast cancers. Assuming an assured high efficiency of the boron agent delivery, the proposed concept can be considered for stage IV HER2+ breast cancers in treating the metastasized tumors in brain, head and neck, and lungs.
Heritability estimates on resting state fMRI data using ENIGMA analysis pipeline.
Adhikari, Bhim M; Jahanshad, Neda; Shukla, Dinesh; Glahn, David C; Blangero, John; Reynolds, Richard C; Cox, Robert W; Fieremans, Els; Veraart, Jelle; Novikov, Dmitry S; Nichols, Thomas E; Hong, L Elliot; Thompson, Paul M; Kochunov, Peter
2018-01-01
Big data initiatives such as the Enhancing NeuroImaging Genetics through Meta-Analysis consortium (ENIGMA), combine data collected by independent studies worldwide to achieve more generalizable estimates of effect sizes and more reliable and reproducible outcomes. Such efforts require harmonized image analyses protocols to extract phenotypes consistently. This harmonization is particularly challenging for resting state fMRI due to the wide variability of acquisition protocols and scanner platforms; this leads to site-to-site variance in quality, resolution and temporal signal-to-noise ratio (tSNR). An effective harmonization should provide optimal measures for data of different qualities. We developed a multi-site rsfMRI analysis pipeline to allow research groups around the world to process rsfMRI scans in a harmonized way, to extract consistent and quantitative measurements of connectivity and to perform coordinated statistical tests. We used the single-modality ENIGMA rsfMRI preprocessing pipeline based on modelfree Marchenko-Pastur PCA based denoising to verify and replicate resting state network heritability estimates. We analyzed two independent cohorts, GOBS (Genetics of Brain Structure) and HCP (the Human Connectome Project), which collected data using conventional and connectomics oriented fMRI protocols, respectively. We used seed-based connectivity and dual-regression approaches to show that the rsfMRI signal is consistently heritable across twenty major functional network measures. Heritability values of 20-40% were observed across both cohorts.
Molinié, Roland; Kwiecień, Renata A; Silvestre, Virginie; Robins, Richard J
2009-12-01
N-Demethylation of tropine is an important step in the degradation of this compound and related metabolites. With the purpose of understanding the reaction mechanism(s) involved, it is desirable to measure the 15N kinetic isotope effects (KIEs), which can be accessed through the 15N isotope shift (Deltadelta15N) during the reaction. To measure the isotope fractionation in 15N during tropine degradation necessitates the extraction of the residual substrate from dilute aqueous solution without introducing artefactual isotope fractionation. Three protocols have been compared for the extraction and measurement of the 15N/14N ratio of tropine from aqueous medium, involving liquid-liquid phase partitioning or silica-C18 solid-phase extraction. Quantification was by gas chromatography (GC) on the recovered organic phase and delta15N values were obtained by isotope ratio measurement mass spectrometry (irm-MS). Although all the protocols used can provide satisfactory data and both irm-EA-MS and irm-GC-MS can be used to obtain the delta15N values, the most convenient method is liquid-liquid extraction from a reduced aqueous volume combined with irm-GC-MS. The protocols are applied to the measurement of 15N isotope shifts during growth of a Pseudomonas strain that uses tropane alkaloids as sole source of carbon and nitrogen. The accuracy of the determination of the 15N/14N ratio is sufficient to be used for the determination of 15N-KIEs. Copyright 2009 John Wiley & Sons, Ltd.
Cicek, M N; Kahyaoglu, I; Kahyaoglu, S
2015-02-01
Elevated progesterone levels surpassing exact treshold values impede endometrial receptivity and decrease clinical pregnancy rates in different responder patients during assisted reproductive techniques. A progesterone (P): estradiol (E2) ratio of > 1 on the day of hCG administration has also been suggested to be a manifestation of low ovarian reserve. The clinical significance of P/E2 ratio on the day of hCG administration was investigated among poor responder patients. Based on the ESHRE Bologna consensus criteria related to poor ovarian response diagnosis, 48 poor responder patients were treated with the microdose flare-up regimen and 34 patients were treated with the multiple-dose GnRH antagonist protocol. All patients were destined to perform a ICSI-ET procedure at the end of the stimulation protocols. Progesterone levels and P/E2 ratios have been detected during controlled ovarian hyperstimulation. In the microdose flare-up group; the duration of stimulation, total gonadotropin dose used and hCG day E2 levels were significantly higher than the multiple dose antagonist group. However, the mean hCG day P/E2 rate in the microdose flare-up group was less than that in the multiple-dose antagonist group. The clinical pregnancy rates were non significantly higher in the multiple dose antagonist protocol group than in microdose flare-up group. Impaired endometrial receptivity caused by elevated P levels results with lower pregnancy rates. Regardless of the selected stimulation protocol, poor responder patients are not prone to exhibit high P and E2 secretion. Increased P/E2 ratio of > 1 on hCG day has limited value to predict cycle outcomes in poor responder patients because of ovarian follicle depletion.
NASA Astrophysics Data System (ADS)
Strocchi, Sabina; Colli, Vittoria; Novario, Raffaele; Carrafiello, Gianpaolo; Giorgianni, Andrea; Macchi, Aldo; Fugazzola, Carlo; Conte, Leopoldo
2007-03-01
Aim of this work is to compare the performances of a Xoran Technologies i-CAT Cone Beam CT for dental applications with those of a standard total body multislice CT (Toshiba Aquilion 64 multislice) used for dental examinations. Image quality and doses to patients have been compared for the three main i-CAT protocols, the Toshiba standard protocol and a Toshiba modified protocol. Images of two phantoms have been acquired: a standard CT quality control phantom and an Alderson Rando ® anthropomorphic phantom. Image noise, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and geometric accuracy have been considered. Clinical image quality was assessed. Effective dose and doses to main head and neck organs were evaluated by means of thermo-luminescent dosimeters (TLD-100) placed in the anthropomorphic phantom. A Quality Index (QI), defined as the ratio of squared CNR to effective dose, has been evaluated. The evaluated effective doses range from 0.06 mSv (i-CAT 10 s protocol) to 2.37 mSv (Toshiba standard protocol). The Toshiba modified protocol (halved tube current, higher pitch value) imparts lower effective dose (0.99 mSv). The conventional CT device provides lower image noise and better SNR, but clinical effectiveness similar to that of dedicated dental CT (comparable CNR and clinical judgment). Consequently, QI values are much higher for this second CT scanner. No geometric distortion has been observed with both devices. As a conclusion, dental volumetric CT supplies adequate image quality to clinical purposes, at doses that are really lower than those imparted by a conventional CT device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raterman, G; Gauntt, D
2014-06-01
Purpose: To propose a method other than CTDI phantom measurements for routine CT dosimetry QA. This consists of taking a series of air exposure measurements and calculating a factor for converting from this exposure measurement to the protocol's associated head or body CTDI value using DLP. The data presented are the ratios of phantom DLP to air exposure ratios for different scanners, as well as error in the displayed CTDI. Methods: For each scanner, the CTDI is measured at all available tube voltages using both the head and body phantoms. Then, the exposure is measured using a pencil chamber inmore » air at isocenter. A ratio of phantom DLP to exposure in air for a given protocol may be calculated and used for converting a simple air dose measurement to a head or body CTDI value. For our routine QA, the exposure in air for different collimations, mAs, and kVp is measured, and displayed CTDI is recorded. Therefore, the ratio calculated may convert these exposures to CTDI values that may then be compared to the displayed CTDI for a large range of acquisition parameter combinations. Results: It was found that all scanners tend to have a ratio factor that slightly increases with kVp. Also, Philips scanners appear to have less of a dependence on kVp; whereas, GE scanners have a lower ratio at lower kVp. The use of air exposure times the DLP conversion yielded CTDI values that were less than 10% different from the displayed CTDI on several scanners. Conclusion: This method may be used as a primary method for CT dosimetry QA. As a result of the ease of measurement, a dosimetry metric specific to that scanner may be calculated for a wide variety of CT protocols, which could also be used to monitor display CTDI value accuracy.« less
Zampieri, Fernando G; Lisboa, Thiago C; Correa, Thiago D; Bozza, Fernando A; Ferez, Marcus; Fernandes, Haggeas S; Japiassú, André M; Verdeal, Juan Carlos R; Carvalho, Ana Cláudia P; Knibel, Marcos F; Mazza, Bruno F; Colombari, Fernando; Vieira, José Mauro; Viana, William N; Costa, Roberto; Godoy, Michele M; Maia, Marcelo O; Caser, Eliana B; Salluh, Jorge I F; Soares, Marcio
2018-01-01
Introduction Higher mortality for patients admitted to intensive care units (ICUs) during the weekends has been occasionally reported with conflicting results that could be related to organisational factors. We investigated the effects of ICU organisational and staffing patterns on the potential association between weekend admission and outcomes in critically ill patients. Methods We included 59 614 patients admitted to 78 ICUs participating during 2013. We defined ‘weekend admission’ as any ICU admission from Friday 19:00 until Monday 07:00. We assessed the association between weekend admission with hospital mortality using a mixed logistic regression model controlling for both patient-level (illness severity, age, comorbidities, performance status and admission type) and ICU-level (decrease in nurse/bed ratio on weekend, full-time intensivist coverage, use of checklists on weekends and number of institutional protocols) confounders. We performed secondary analyses in the subgroup of scheduled surgical admissions. Results A total of 41 894 patients (70.3%) were admitted on weekdays and 17 720 patients (29.7%) on weekends. In univariable analysis, weekend admitted patients had higher ICU (10.9% vs 9.0%, P<0.001) and hospital (16.5% vs 13.5%, P<0.001) mortality. After adjusting for confounders, weekend admission was not associated with higher hospital mortality (OR 1.05, 95% CI 0.99 to 1.12, P=0.095). However, a ‘weekend effect’ was still observed in scheduled surgical admissions, as well as in ICUs not using checklists during the weekends. For unscheduled admissions, no ‘weekend effect’ was observed regardless of ICU’s characteristics. For scheduled surgical admissions, a ‘weekend effect’ was present only in ICUs with a low number of implemented protocols and those with a reduction in the nurse/bed ratio and not applying checklists during weekends. Conclusions ICU organisational factors, such as decreased nurse-to-patient ratio, absence of checklists and fewer standardised protocols, may explain, in part, increases in mortality in patients admitted to the ICU mortality on weekends. PMID:29371274
NASA Astrophysics Data System (ADS)
Cheng, Yuan; Duan, Feng-kui; He, Ke-bin; Du, Zhen-yu; Zheng, Mei; Ma, Yong-liang
2012-12-01
Three temperature protocols with different peak inert mode temperature (Tpeak-inert) were compared based on source and ambient samples (both untreated and extracted using a mixture of hexane, methylene chloride, and acetone) collected in Beijing, China. The ratio of EC580 (elemental carbon measured by the protocol with a Tpeak-inert of 580 °C; similar hereinafter) to EC850 could be as high as 4.8 for biomass smoke samples whereas the ratio was about 1.0 for diesel and gasoline exhaust samples. The EC580 to EC850 ratio averaged 1.95 ± 0.89 and 1.13 ± 0.20 for the untreated and extracted ambient samples, whereas the EC580 to EC650 ratio of ambient samples was 1.22 ± 0.10 and 1.20 ± 0.12 before and after extraction. It was suggested that there are two competing mechanisms for the effects of Tpeak-inert on the EC results such that when Tpeak-inert is increased, one mechanism tends to decrease EC by increasing the amount of charring whereas the other tends to increase EC through promoting more charring to evolve before native EC. Results from this study showed that EC does not always decrease when increasing the peak inert mode temperature. Moreover, reducing the charring amount could improve the protocols agreement on EC measurements, whereas temperature protocol would not influence the EC results if no charring is formed. This study also demonstrated the benefits of allowing for the OC and EC split occurring in the inert mode when a high Tpeak-inert is used (e.g., 850 °C).
Kobayashi, Yasuhiro; Kumita, Shin-ichiro; Fukushima, Yoshimitsu; Ishihara, Keiichi; Suda, Masaya; Sakurai, Minoru
2013-11-01
(18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) is a useful tool for evaluating inflammation. Because, myocardial-FDG uptake occurs with diverse physiology, it should be suppressed during evaluation of myocardial inflammation by FDG-PET/CT. Diets inducing fat-based metabolism, such as a low-carbohydrate, high-fat diet (LCHF), are used in uptake-suppression protocols. However, a complete suppression of myocardial-FDG uptake has not been established. Hence, we assessed the efficacy of 24-h carbohydrate restriction along with an LCHF diet compared to that of the conventional protocol in suppressing myocardial-FDG uptake and also compared fat and glucose metabolism between these protocols. Fourteen healthy volunteers agreed to undergo >24-h carbohydrate restriction (glucose, <10g) and drank an LCHF beverage an hour before FDG administration. A scan performed under conventional fasting protocol served as the control. The maximal standardized uptake values (SUVmax) of the left ventricular (LV) myocardium, and left atrium lumen (blood pool), liver, and lung fields as background, were measured. Blood sugar, free fatty acids (FFAs), insulin, and triglyceride concentrations were measured just before FDG injection and compared between the 2 protocols. Global LV myocardial uptake was significantly lower with the diet-preparation protocol (SUVmax 1.31 [1.15-1.49] vs. 2.98 [1.76-6.43], p=0.001). Target-to-background ratios [myocardium-to-blood ratio (MBR), myocardium-to-lung ratio (MLR), and myocardium-to-liver ratio (MLvR)] were also significantly lower with the diet-preparation protocol [MBR: 0.75 (0.68-0.84) vs. 1.63 (0.98-4.09), p<0.001; MLR: 1.87 (1.53-2.47) vs. 4.54 (2.53-12.78), p=0.004; MLvR: 0.48 (0.44-0.56) vs. 1.11 (0.63-2.32), p=0.002]. Only insulin levels were significantly different between the subjects in each protocol group (11.3 [6.2-15.1] vs. 3.9 [2.9-6.2]). Carbohydrate restriction together with an LCHF supplement administered 1h before FDG significantly suppressed myocardial-FDG uptake. FFAs and insulin might not directly affect myocardial-FDG uptake. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
2010-01-01
Introduction Accurate assessment of estrogen receptor (ER), progesterone receptor (PR), and Ki-67 is essential in the histopathologic diagnostics of breast cancer. Commercially available image analysis systems are usually bundled with dedicated analysis hardware and, to our knowledge, no easily installable, free software for immunostained slide scoring has been described. In this study, we describe a free, Internet-based web application for quantitative image analysis of ER, PR, and Ki-67 immunohistochemistry in breast cancer tissue sections. Methods The application, named ImmunoRatio, calculates the percentage of positively stained nuclear area (labeling index) by using a color deconvolution algorithm for separating the staining components (diaminobenzidine and hematoxylin) and adaptive thresholding for nuclear area segmentation. ImmunoRatio was calibrated using cell counts defined visually as the gold standard (training set, n = 50). Validation was done using a separate set of 50 ER, PR, and Ki-67 stained slides (test set, n = 50). In addition, Ki-67 labeling indexes determined by ImmunoRatio were studied for their prognostic value in a retrospective cohort of 123 breast cancer patients. Results The labeling indexes by calibrated ImmunoRatio analyses correlated well with those defined visually in the test set (correlation coefficient r = 0.98). Using the median Ki-67 labeling index (20%) as a cutoff, a hazard ratio of 2.2 was obtained in the survival analysis (n = 123, P = 0.01). ImmunoRatio was shown to adapt to various staining protocols, microscope setups, digital camera models, and image acquisition settings. The application can be used directly with web browsers running on modern operating systems (e.g., Microsoft Windows, Linux distributions, and Mac OS). No software downloads or installations are required. ImmunoRatio is open source software, and the web application is publicly accessible on our website. Conclusions We anticipate that free web applications, such as ImmunoRatio, will make the quantitative image analysis of ER, PR, and Ki-67 easy and straightforward in the diagnostic assessment of breast cancer specimens. PMID:20663194
Tuominen, Vilppu J; Ruotoistenmäki, Sanna; Viitanen, Arttu; Jumppanen, Mervi; Isola, Jorma
2010-01-01
Accurate assessment of estrogen receptor (ER), progesterone receptor (PR), and Ki-67 is essential in the histopathologic diagnostics of breast cancer. Commercially available image analysis systems are usually bundled with dedicated analysis hardware and, to our knowledge, no easily installable, free software for immunostained slide scoring has been described. In this study, we describe a free, Internet-based web application for quantitative image analysis of ER, PR, and Ki-67 immunohistochemistry in breast cancer tissue sections. The application, named ImmunoRatio, calculates the percentage of positively stained nuclear area (labeling index) by using a color deconvolution algorithm for separating the staining components (diaminobenzidine and hematoxylin) and adaptive thresholding for nuclear area segmentation. ImmunoRatio was calibrated using cell counts defined visually as the gold standard (training set, n = 50). Validation was done using a separate set of 50 ER, PR, and Ki-67 stained slides (test set, n = 50). In addition, Ki-67 labeling indexes determined by ImmunoRatio were studied for their prognostic value in a retrospective cohort of 123 breast cancer patients. The labeling indexes by calibrated ImmunoRatio analyses correlated well with those defined visually in the test set (correlation coefficient r = 0.98). Using the median Ki-67 labeling index (20%) as a cutoff, a hazard ratio of 2.2 was obtained in the survival analysis (n = 123, P = 0.01). ImmunoRatio was shown to adapt to various staining protocols, microscope setups, digital camera models, and image acquisition settings. The application can be used directly with web browsers running on modern operating systems (e.g., Microsoft Windows, Linux distributions, and Mac OS). No software downloads or installations are required. ImmunoRatio is open source software, and the web application is publicly accessible on our website. We anticipate that free web applications, such as ImmunoRatio, will make the quantitative image analysis of ER, PR, and Ki-67 easy and straightforward in the diagnostic assessment of breast cancer specimens.
Kirkpatrick, Daniel L; Hasham, Hasnain; Collins, Zachary; Johnson, Philip; Lemons, Steven; Shahzada, Hassan; Hunt, Suzanne L; Walter, Carissa; Hill, Jacqueline; Fahrbach, Thomas
2018-05-01
To determine whether treating benign biliary strictures via a stricture protocol reduced the probability of developing symptomatic recurrence and requiring surgical revision compared to nonprotocol treatment. A stricture protocol was designed to include serial upsizing of internal/external biliary drainage catheters to a target maximum dilation of 18-French, optional cholangioplasty at each upsizing, and maintenance of the largest catheter for at least 6 months. Patients were included in this retrospective analysis if they underwent biliary ductal dilation at a single institution from 2005 to 2016. Forty-two patients were included, 25 women and 17 men, with an average age of 51.9 years (standard deviation ± 14.6). Logistic regression models were used to determine the probability of symptomatic recurrence and surgical revision by stricture treatment type. Twenty-two patients received nonprotocol treatment, while 20 received treatment on a stricture protocol. After treatment, 7 (32%) patients in the nonprotocol group experienced clinical or laboratory recurrence of a benign stricture, whereas only 1 patient in the stricture protocol group experienced symptom recurrence. Patients in the protocol group were 8.9 times (95% confidence interval [CI] = 1.4-175.3) more likely to remain symptom free than patients in the nonprotocol group. Moreover, patients in the protocol group had an estimated 89% reduction in the probability of undergoing surgical revision compared to patients receiving nonprotocol treatment (odds ratio = .11, 95% CI = .01-.73). Establishing a stricture protocol may decrease the risk of stricture recurrence and the need for surgical revision when compared to a nonprotocol treatment approach. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
An improved ATAC-seq protocol reduces background and enables interrogation of frozen tissues.
Corces, M Ryan; Trevino, Alexandro E; Hamilton, Emily G; Greenside, Peyton G; Sinnott-Armstrong, Nicholas A; Vesuna, Sam; Satpathy, Ansuman T; Rubin, Adam J; Montine, Kathleen S; Wu, Beijing; Kathiria, Arwa; Cho, Seung Woo; Mumbach, Maxwell R; Carter, Ava C; Kasowski, Maya; Orloff, Lisa A; Risca, Viviana I; Kundaje, Anshul; Khavari, Paul A; Montine, Thomas J; Greenleaf, William J; Chang, Howard Y
2017-10-01
We present Omni-ATAC, an improved ATAC-seq protocol for chromatin accessibility profiling that works across multiple applications with substantial improvement of signal-to-background ratio and information content. The Omni-ATAC protocol generates chromatin accessibility profiles from archival frozen tissue samples and 50-μm sections, revealing the activities of disease-associated DNA elements in distinct human brain structures. The Omni-ATAC protocol enables the interrogation of personal regulomes in tissue context and translational studies.
Quantitative image feature variability amongst CT scanners with a controlled scan protocol
NASA Astrophysics Data System (ADS)
Ger, Rachel B.; Zhou, Shouhao; Chi, Pai-Chun Melinda; Goff, David L.; Zhang, Lifei; Lee, Hannah J.; Fuller, Clifton D.; Howell, Rebecca M.; Li, Heng; Stafford, R. Jason; Court, Laurence E.; Mackin, Dennis S.
2018-02-01
Radiomics studies often analyze patient computed tomography (CT) images acquired from different CT scanners. This may result in differences in imaging parameters, e.g. different manufacturers, different acquisition protocols, etc. However, quantifiable differences in radiomics features can occur based on acquisition parameters. A controlled protocol may allow for minimization of these effects, thus allowing for larger patient cohorts from many different CT scanners. In order to test radiomics feature variability across different CT scanners a radiomics phantom was developed with six different cartridges encased in high density polystyrene. A harmonized protocol was developed to control for tube voltage, tube current, scan type, pitch, CTDIvol, convolution kernel, display field of view, and slice thickness across different manufacturers. The radiomics phantom was imaged on 18 scanners using the control protocol. A linear mixed effects model was created to assess the impact of inter-scanner variability with decomposition of feature variation between scanners and cartridge materials. The inter-scanner variability was compared to the residual variability (the unexplained variability) and to the inter-patient variability using two different patient cohorts. The patient cohorts consisted of 20 non-small cell lung cancer (NSCLC) and 30 head and neck squamous cell carcinoma (HNSCC) patients. The inter-scanner standard deviation was at least half of the residual standard deviation for 36 of 49 quantitative image features. The ratio of inter-scanner to patient coefficient of variation was above 0.2 for 22 and 28 of the 49 features for NSCLC and HNSCC patients, respectively. Inter-scanner variability was a significant factor compared to patient variation in this small study for many of the features. Further analysis with a larger cohort will allow more thorough analysis with additional variables in the model to truly isolate the interscanner difference.
Chauhan, Balwantray C; Nicolela, Marcelo T; Artes, Paul H
2009-11-01
To determine whether glaucoma patients with progressive optic disc change have subsequent visual field progression earlier and at a faster rate compared with those without disc change. Prospective, longitudinal, cohort study. Eighty-one patients with open-angle glaucoma. Patients underwent confocal scanning laser tomography and standard automated perimetry every 6 months. The complete follow-up was divided into initial and subsequent periods. Two initial periods-first 3 years (Protocol A) and first half of the total follow-up (Protocol B)-were used, with the respective remainder being the subsequent follow-up. Disc change during the initial follow-up was determined with liberal, moderate, or conservative criteria of the Topographic Change Analysis. Subsequent field progression was determined with significant pattern deviation change in >or=3 locations (criterion used in the Early Manifest Glaucoma Trial). As a control analysis, field change during the initial follow-up was determined with significant pattern deviation change in >or=1, >or=2, or >or=3 locations. Survival time to subsequent field progression, rates of mean deviation (MD) change, and positive and negative likelihood ratios. The median (interquartile range) total follow-up was 11.0 (8.0-12.0) years with 22 (18-24) examinations. More patients had disc changes during the initial follow-up compared with field changes. The mean time to field progression was consistently shorter (protocol A, 0.8-1.7 years; protocol B, 0.3-0.7 years) in patients with prior disc change. In the control analysis, patients with prior field change had statistically earlier subsequent field progression (protocol A, 2.9-3.0 years; protocol B, 0.7-0.9). Similarly, patients with either prior disc or field change always had worse mean rates of subsequent MD change, although the distributions overlapped widely. Patients with subsequent field progression were up to 3 times more likely to have prior disc change compared with those without, and up to 5 times more likely to have prior field change compared with those without. Longitudinally measured optic disc change is predictive of subsequent visual field progression and may be an efficacious end point for functional outcomes in clinical studies and trials in glaucoma.
Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav
2017-01-01
Objectives: To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Methods: Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. Results: TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). Conclusions: MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T. PMID:27704872
Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav; Manoliu, Andrei
2017-01-01
To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T.
Management of Malignant Pleural Effusion: A Cost-Utility Analysis.
Shafiq, Majid; Frick, Kevin D; Lee, Hans; Yarmus, Lonny; Feller-Kopman, David J
2015-07-01
Malignant pleural effusion (MPE) is associated with a significant impact on health-related quality of life. Palliative interventions abound, with varying costs and degrees of invasiveness. We examined the relative cost-utility of 5 therapeutic alternatives for MPE among adults. Original studies investigating the management of MPE were extensively researched, and the most robust and current data particularly those from the TIME2 trial were chosen to estimate event probabilities. Medicare data were used for cost estimation. Utility estimates were adapted from 2 original studies and kept consistent with prior estimations. The decision tree model was based on clinical guidelines and authors' consensus opinion. Primary outcome of interest was the incremental cost-effectiveness ratio for each intervention over a less effective alternative over an analytical horizon of 6 months. Given the paucity of data on rapid pleurodesis protocol, a sensitivity analysis was conducted to address the uncertainty surrounding its efficacy in terms of achieving long-term pleurodesis. Except for repeated thoracentesis (RT; least effective), all interventions had similar effectiveness. Tunneled pleural catheter was the most cost-effective option with an incremental cost-effectiveness ratio of $45,747 per QALY gained over RT, assuming a willingness-to-pay threshold of $100,000/QALY. Multivariate sensitivity analysis showed that rapid pleurodesis protocol remained cost-ineffective even with an estimated probability of lasting pleurodesis up to 85%. Tunneled pleural catheter is the most cost-effective therapeutic alternative to RT. This, together with its relative convenience (requiring neither hospitalization nor thoracoscopic procedural skills), makes it an intervention of choice for MPE.
Clemensson, Erik Karl Håkan; Clemensson, Laura Emily; Fabry, Benedikt; Riess, Olaf; Nguyen, Huu Phuc
2017-01-01
Huntington disease is an inherited neurodegenerative disorder characterized by motor, cognitive, psychiatric and metabolic symptoms. We recently published a study describing that the BACHD rat model of HD shows an obesity phenotype, which might affect their motivation to perform food-based behavioral tests. Further, we argued that using a food restriction protocol based on matching BACHD and wild type rats' food consumption rates might resolve these motivational differences. In the current study, we followed up on these ideas in a longitudinal study of the rats' performance in a progressive ratio test. We also investigated the phenotype of reduced food consumption rate, which is typically seen in food-restricted BACHD rats, in greater detail. In line with our previous study, the BACHD rats were less motivated to perform the progressive ratio test compared to their wild type littermates, although the phenotype was no longer present when the rats' food consumption rates had been matched. However, video analysis of food consumption tests suggested that the reduced consumption rate found in the BACHD rats was not entirely based on differences in hunger, but likely involved motoric impairments. Thus, restriction protocols based on food consumption rates are not appropriate when working with BACHD rats. As an alternative, we suggest that studies where BACHD rats are used should investigate how the readouts of interest are affected by motivational differences, and use appropriate control tests to avoid misleading results. In addition, we show that BACHD rats display distinct behavioral changes in their progressive ratio performance, which might be indicative of striatal dysfunction.
Mhaskar, Rahul; Djulbegovic, Benjamin; Magazin, Anja; Soares, Heloisa P.; Kumar, Ambuj
2011-01-01
Objectives To assess whether reported methodological quality of randomized controlled trials (RCTs) reflect the actual methodological quality, and to evaluate the association of effect size (ES) and sample size with methodological quality. Study design Systematic review Setting Retrospective analysis of all consecutive phase III RCTs published by 8 National Cancer Institute Cooperative Groups until year 2006. Data were extracted from protocols (actual quality) and publications (reported quality) for each study. Results 429 RCTs met the inclusion criteria. Overall reporting of methodological quality was poor and did not reflect the actual high methodological quality of RCTs. The results showed no association between sample size and actual methodological quality of a trial. Poor reporting of allocation concealment and blinding exaggerated the ES by 6% (ratio of hazard ratio [RHR]: 0.94, 95%CI: 0.88, 0.99) and 24% (RHR: 1.24, 95%CI: 1.05, 1.43), respectively. However, actual quality assessment showed no association between ES and methodological quality. Conclusion The largest study to-date shows poor quality of reporting does not reflect the actual high methodological quality. Assessment of the impact of quality on the ES based on reported quality can produce misleading results. PMID:22424985
Inui, Yoshitaka; Ichihara, Takashi; Uno, Masaki; Ishiguro, Masanobu; Ito, Kengo; Kato, Katsuhiko; Sakuma, Hajime; Okazawa, Hidehiko; Toyama, Hiroshi
2018-06-01
Statistical image analysis of brain SPECT images has improved diagnostic accuracy for brain disorders. However, the results of statistical analysis vary depending on the institution even when they use a common normal database (NDB), due to different intrinsic spatial resolutions or correction methods. The present study aimed to evaluate the correction of spatial resolution differences between equipment and examine the differences in skull bone attenuation to construct a common NDB for use in multicenter settings. The proposed acquisition and processing protocols were those routinely used at each participating center with additional triple energy window (TEW) scatter correction (SC) and computed tomography (CT) based attenuation correction (CTAC). A multicenter phantom study was conducted on six imaging systems in five centers, with either single photon emission computed tomography (SPECT) or SPECT/CT, and two brain phantoms. The gray/white matter I-123 activity ratio in the brain phantoms was 4, and they were enclosed in either an artificial adult male skull, 1300 Hounsfield units (HU), a female skull, 850 HU, or an acrylic cover. The cut-off frequency of the Butterworth filters was adjusted so that the spatial resolution was unified to a 17.9 mm full width at half maximum (FWHM), that of the lowest resolution system. The gray-to-white matter count ratios were measured from SPECT images and compared with the actual activity ratio. In addition, mean, standard deviation and coefficient of variation images were calculated after normalization and anatomical standardization to evaluate the variability of the NDB. The gray-to-white matter count ratio error without SC and attenuation correction (AC) was significantly larger for higher bone densities (p < 0.05). The count ratio error with TEW and CTAC was approximately 5% regardless of bone density. After adjustment of the spatial resolution in the SPECT images, the variability of the NDB decreased and was comparable to that of the NDB without correction. The proposed protocol showed potential for constructing an appropriate common NDB from SPECT images with SC, AC and spatial resolution compensation.
Bengtsson, Henrik; Jönsson, Göran; Vallon-Christersson, Johan
2004-11-12
Non-linearities in observed log-ratios of gene expressions, also known as intensity dependent log-ratios, can often be accounted for by global biases in the two channels being compared. Any step in a microarray process may introduce such offsets and in this article we study the biases introduced by the microarray scanner and the image analysis software. By scanning the same spotted oligonucleotide microarray at different photomultiplier tube (PMT) gains, we have identified a channel-specific bias present in two-channel microarray data. For the scanners analyzed it was in the range of 15-25 (out of 65,535). The observed bias was very stable between subsequent scans of the same array although the PMT gain was greatly adjusted. This indicates that the bias does not originate from a step preceding the scanner detector parts. The bias varies slightly between arrays. When comparing estimates based on data from the same array, but from different scanners, we have found that different scanners introduce different amounts of bias. So do various image analysis methods. We propose a scanning protocol and a constrained affine model that allows us to identify and estimate the bias in each channel. Backward transformation removes the bias and brings the channels to the same scale. The result is that systematic effects such as intensity dependent log-ratios are removed, but also that signal densities become much more similar. The average scan, which has a larger dynamical range and greater signal-to-noise ratio than individual scans, can then be obtained. The study shows that microarray scanners may introduce a significant bias in each channel. Such biases have to be calibrated for, otherwise systematic effects such as intensity dependent log-ratios will be observed. The proposed scanning protocol and calibration method is simple to use and is useful for evaluating scanner biases or for obtaining calibrated measurements with extended dynamical range and better precision. The cross-platform R package aroma, which implements all described methods, is available for free from http://www.maths.lth.se/bioinformatics/.
Cox, Helen S.; Mbhele, Slindile; Mohess, Neisha; Whitelaw, Andrew; Muller, Odelia; Zemanay, Widaad; Little, Francesca; Azevedo, Virginia; Simpson, John; Boehme, Catharina C.; Nicol, Mark P.
2014-01-01
Background Xpert MTB/RIF is approved for use in tuberculosis (TB) and rifampicin-resistance diagnosis. However, data are limited on the impact of Xpert under routine conditions in settings with high TB burden. Methods and Findings A pragmatic prospective cluster-randomised trial of Xpert for all individuals with presumptive (symptomatic) TB compared to the routine diagnostic algorithm of sputum microscopy and limited use of culture was conducted in a large TB/HIV primary care clinic. The primary outcome was the proportion of bacteriologically confirmed TB cases not initiating TB treatment by 3 mo after presentation. Secondary outcomes included time to TB treatment and mortality. Unblinded randomisation occurred on a weekly basis. Xpert and smear microscopy were performed on site. Analysis was both by intention to treat (ITT) and per protocol. Between 7 September 2010 and 28 October 2011, 1,985 participants were assigned to the Xpert (n = 982) and routine (n = 1,003) diagnostic algorithms (ITT analysis); 882 received Xpert and 1,063 routine (per protocol analysis). 13% (32/257) of individuals with bacteriologically confirmed TB (smear, culture, or Xpert) did not initiate treatment by 3 mo after presentation in the Xpert arm, compared to 25% (41/167) in the routine arm (ITT analysis, risk ratio 0.51, 95% CI 0.33–0.77, p = 0.0052). The yield of bacteriologically confirmed TB cases among patients with presumptive TB was 17% (167/1,003) with routine diagnosis and 26% (257/982) with Xpert diagnosis (ITT analysis, risk ratio 1.57, 95% CI 1.32–1.87, p<0.001). This difference in diagnosis rates resulted in a higher rate of treatment initiation in the Xpert arm: 23% (229/1,003) and 28% (277/982) in the routine and Xpert arms, respectively (ITT analysis, risk ratio 1.24, 95% CI 1.06–1.44, p = 0.013). Time to treatment initiation was improved overall (ITT analysis, hazard ratio 0.76, 95% CI 0.63–0.92, p = 0.005) and among HIV-infected participants (ITT analysis, hazard ratio 0.67, 95% CI 0.53–0.85, p = 0.001). There was no difference in 6-mo mortality with Xpert versus routine diagnosis. Study limitations included incorrect intervention allocation for a high proportion of participants and that the study was conducted in a single clinic. Conclusions These data suggest that in this routine primary care setting, use of Xpert to diagnose TB increased the number of individuals with bacteriologically confirmed TB who were treated by 3 mo and reduced time to treatment initiation, particularly among HIV-infected participants. Trial registration Pan African Clinical Trials Registry PACTR201010000255244 Please see later in the article for the Editors' Summary PMID:25423041
Flow cytometry for enrichment and titration in massively parallel DNA sequencing
Sandberg, Julia; Ståhl, Patrik L.; Ahmadian, Afshin; Bjursell, Magnus K.; Lundeberg, Joakim
2009-01-01
Massively parallel DNA sequencing is revolutionizing genomics research throughout the life sciences. However, the reagent costs and labor requirements in current sequencing protocols are still substantial, although improvements are continuously being made. Here, we demonstrate an effective alternative to existing sample titration protocols for the Roche/454 system using Fluorescence Activated Cell Sorting (FACS) technology to determine the optimal DNA-to-bead ratio prior to large-scale sequencing. Our method, which eliminates the need for the costly pilot sequencing of samples during titration is capable of rapidly providing accurate DNA-to-bead ratios that are not biased by the quantification and sedimentation steps included in current protocols. Moreover, we demonstrate that FACS sorting can be readily used to highly enrich fractions of beads carrying template DNA, with near total elimination of empty beads and no downstream sacrifice of DNA sequencing quality. Automated enrichment by FACS is a simple approach to obtain pure samples for bead-based sequencing systems, and offers an efficient, low-cost alternative to current enrichment protocols. PMID:19304748
Multicasting in Wireless Communications (Ad-Hoc Networks): Comparison against a Tree-Based Approach
NASA Astrophysics Data System (ADS)
Rizos, G. E.; Vasiliadis, D. C.
2007-12-01
We examine on-demand multicasting in ad hoc networks. The Core Assisted Mesh Protocol (CAMP) is a well-known protocol for multicast routing in ad-hoc networks, generalizing the notion of core-based trees employed for internet multicasting into multicast meshes that have much richer connectivity than trees. On the other hand, wireless tree-based multicast routing protocols use much simpler structures for determining route paths, using only parent-child relationships. In this work, we compare the performance of the CAMP protocol against the performance of wireless tree-based multicast routing protocols, in terms of two important factors, namely packet delay and ratio of dropped packets.
Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.
Kim, Hyun Gi; Lee, Ho-Joon; Lee, Seung-Koo; Kim, Hyun Ji; Kim, Myung-Joon
2017-09-01
To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols. A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for <3-year-old patients and applied 30% ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V. Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P < 0.001). Qualitative analysis showed higher gray-white matter differentiation and sharpness and preserved overall diagnostic quality in the images with ASIR-V. Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality. • It is possible to reduce radiation dose and improve image quality with ASIR-V. • We improved noise and CNR and decreased radiation dose. • Sharpness improved with ASIR-V. • Total radiation dose was decreased by 12.8% to 34.0%.
Physician Nonadherence With a Hepatitis C Screening Program
Southern, William N.; Drainoni, Mari-Lynn; Smith, Bryce D.; Koppelman, Elisa; McKee, M. Diane; Christiansen, Cindy L.; Gifford, Allen L.; Weinbaum, Cindy M.; Litwin, Alain H.
2017-01-01
Background Testing for patients at risk for hepatitis C virus (HCV) infection is recommended, but it is unclear whether providers adhere to testing guidelines. We aimed to measure adherence to an HCV screening protocol during a multifaceted continuous intervention. Subjects and Methods Prospective cohort design to examine the associations between patient-level, physician-level, and visit-level characteristics and adherence to an HCV screening protocol. Study participants included all patients with a visit to 1 of the 3 study clinics and the physicians who cared for them. Adherence to the HCV screening protocol and patient-level, physician-level, and visit-level predictors of adherence were measured. Results A total of 8981 patients and 154 physicians were examined. Overall protocol adherence rate was 36.1%. In multivariate analysis, patient male sex (odds ratio [OR] = 1.18), new patient (OR = 1.23), morning visit (OR = 1.32), and patients’ preferred language being non-English (OR = 0.87) were significantly associated with screening adherence. There was a wide variation in overall adherence among physicians (range, 0%–92.4%). Screening adherence continuously declined from 59.1% in week 1 of the study to 13.7% in week 15 (final week). When implementing complex clinical practice guidelines, planners should address physician attitudinal barriers as well as gaps in knowledge to maximize adherence. PMID:24368717
Kaitani, Toshiko; Nakagami, Gojiro; Iizaka, Shinji; Fukuda, Takashi; Oe, Makoto; Igarashi, Ataru; Mori, Taketoshi; Takemura, Yukie; Mizokami, Yuko; Sugama, Junko; Sanada, Hiromi
2015-01-01
The high prevalence of severe pressure ulcers (PUs) is an important issue that requires to be highlighted in Japan. In a previous study, we devised an advanced PU management protocol to enable early detection of and intervention for deep tissue injury and critical colonization. This protocol was effective for preventing more severe PUs. The present study aimed to compare the cost-effectiveness of the care provided using an advanced PU management protocol, from a medical provider's perspective, implemented by trained wound, ostomy, and continence nurses (WOCNs), with that of conventional care provided by a control group of WOCNs. A Markov model was constructed for a 1-year time horizon to determine the incremental cost-effectiveness ratio of advanced PU management compared with conventional care. The number of quality-adjusted life-years gained, and the cost in Japanese yen (¥) ($US1 = ¥120; 2015) was used as the outcome. Model inputs for clinical probabilities and related costs were based on our previous clinical trial results. Univariate sensitivity analyses were performed. Furthermore, a Bayesian multivariate probability sensitivity analysis was performed using Monte Carlo simulations with advanced PU management. Two different models were created for initial cohort distribution. For both models, the expected effectiveness for the intervention group using advanced PU management techniques was high, with a low expected cost value. The sensitivity analyses suggested that the results were robust. Intervention by WOCNs using advanced PU management techniques was more effective and cost-effective than conventional care. © 2015 by the Wound Healing Society.
Ahmadizad, Sajad; Bassami, Minoo; Hadian, Mohsen; Eslami, Maryam
2016-01-01
Acute effects of continuous exercise on the markers of blood fluidity have been addressed in different populations and the changes are intensity related. However, the effect of different high intensity interval exercise (HIIE) on these variables is unclear. This study is designed to determine the effects of two different HIIE with different work/rest ratios but the same energy expenditure on the main determinants of blood fluidity. Ten overweight men (age, 26.3±1.7 yrs) completed two HIIE protocols on two separate occasions with one week intervening. The two HIIE encompassed performing: 1) 6 intervals of 2 min activity at 85% of VO2max interspersed by 2 min active recovery at 30% of VO2max (ratio 1 to 1, HIIE1/1), and 2) 6 intervals of 30 s activity at 110% of VO2max interspersed by 4 min active recovery at 40% of VO2max (ratio 1 to 8, HIIE1/8). Each exercise trial was followed by 30 min rest. Venous blood samples were obtained before exercise, immediately after exercise and after recovery and analyzed for blood and plasma viscosity, fibrinogen and red blood cell indices. The HIIE1/1 protocol led to higher reduction (P < 0.01) in plasma volume changes compared to HIIE1/8 (9.9% vs 5.7%). Moreover, increases in blood viscosity, plasma viscosity, hematocrit, RBC count and mean arterial blood pressure observed following HIIE1/1 were significantly (P < 0.05) higher than HIIE1/8 ; whereas, the changes in fibrinogen concentration neither were significant in response to both trials nor were significantly different between two protocols (P > 0.05). However, the changes in all variables during exercise were transient and returned to the baseline levels after 30 min recovery. It is concluded that the HIIE protocol with lower intensity and shorter rest intervals (higher work to rest ratio) clearly results in more physiological strain than HIIE with higher intensity but longer rest intervals (lower work to rest ratio) in overweight individuals, and that the work to rest ratio could be as important as exercise intensity when considering the hemorheological variables during HIIE.
Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki
2016-01-01
The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weiss, Kevin L; Meilleur, Flora; Blakeley, Matthew
2008-01-01
Neutron crystallography is used to locate hydrogen atoms in biological materials and can distinguish between negatively scattering hydrogen and positively scattering deuterium substituted positions in isomorphous neutron structures. Recently, Hauptman and Langs (2003) have shown that neutron diffraction data can be used to solve macromolecular structures by direct methods and that solution is aided by the presence of negatively scattering hydrogen atoms in the structure. Selective labeling protocols allow the design and production of H/D-labeled macromolecular structures in which the ratio of hydrogen to deuterium atoms can be precisely controlled. We have applied methyl-selective labeling protocols to introduce (1H-delta methyl)-leucinemore » and (1H-gamma methyl)-valine into deuterated rubredoxin from Pyrococcus furiosus (PfRd). Here we report on the production, crystallization, and preliminary neutron analysis of the selectively CH3-protonated, deuterated PfRd sample, which provided a high quality neutron data set extending to 1.75 resolution at the new LADI-III instrument at the Insititut Laue-Langevin. Preliminary analysis of neutron density maps allows unambiguous assignment of the positions of hydrogen atoms at the methyl groups of the valine and leucine residues in the otherwise deuterated rubredoxin structure.« less
Downing, Amanda; Mortimer, Molly; Hiers, Jill
2016-03-01
Warfarin is a high alert medication and a challenge to dose and monitor. Pharmacist-driven warfarin management has been shown to decrease the time international normalized ratio (INR) is out of range, which may reduce undesired outcomes. The purpose of this study is to assess the effect of the implementation of a pharmacist-driven warfarin management protocol on the achievement of therapeutic INRs. A warfarin management protocol was developed using evidence based literature and similar protocols from other institutions. Pharmacists utilized the protocol to provide patient specific warfarin dosing upon provider referral. To evaluate the protocol's impact, a retrospective chart review pre- and post-implementation was completed for admitted patients receiving warfarin. Three hundred twenty-seven charts were reviewed for pre- and post-implementation data. INRs within therapeutic range increased from 27.8% before protocol implementation to 38.5% after implementation. There was also a reduction in subtherapeutic INRs (55.3% pre to 39% post) and supratherapeutic INRs 5 or above (3.7% pre to 2.6% post). Supratherapeutic INRs between 3 and 5 did increase from 13.2% before protocol implementation to 19.9% in the pharmacist managed group. In addition to reducing the time to achievement of therapeutic INRs by 0.5 days, implementation of the protocol resulted in an increased the number of patients with at least one therapeutic INR during admission (35% pre to 40% post). The implementation of a pharmacist-driven warfarin dosing protocol increased therapeutic INRs, and decreased the time to therapeutic range, as well as the proportion of subtherapeutic INRs and supratherapeutic INRs 5 or greater. Additional benefits of the protocol include documentation of Joint Commission National Patient Safety Goal compliance, promotion of interdisciplinary collaboration and increased continuity of care. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
The Network Protocol Analysis Technique in Snort
NASA Astrophysics Data System (ADS)
Wu, Qing-Xiu
Network protocol analysis is a network sniffer to capture data for further analysis and understanding of the technical means necessary packets. Network sniffing is intercepted by packet assembly binary format of the original message content. In order to obtain the information contained. Required based on TCP / IP protocol stack protocol specification. Again to restore the data packets at protocol format and content in each protocol layer. Actual data transferred, as well as the application tier.
Sun, Ruoyu; Enrico, Maxime; Heimbürger, Lars-Eric; Scott, Clint; Sonke, Jeroen E
2013-08-01
High-precision mercury (Hg) stable isotopic analysis requires relatively large amounts of Hg (>10 ng). Consequently, the extraction of Hg from natural samples with low Hg concentrations (<1-20 ng/g) by wet chemistry is challenging. Combustion-trapping techniques have been shown to be an appropriate alternative. Here, we detail a modified off-line Hg pre-concentration protocol that is based on combustion and trapping. Hg in solid samples is thermally reduced and volatilized in a pure O2 stream using a temperature-programmed combustion furnace. A second furnace, kept at 1,000 °C, decomposes combustion products into H2O, CO2, SO2, etc. The O2 carrier gas, including combustion products and elemental Hg, is then purged into a 40% (v/v) acid-trapping solution. The method was optimized by assessing the variations of Hg pre-concentration efficiency and Hg isotopic compositions as a function of acid ratio, gas flow rate, and temperature ramp rate for two certified reference materials of bituminous coals. Acid ratios of 2HNO3/1HCl (v/v), 25 mL/min O2 flow rate, and a dynamic temperature ramp rate (15 °C/min for 25-150 and 600-900 °C; 2.5 °C/min for 150-600 °C) were found to give optimal results. Hg step-release experiments indicated that significant Hg isotopic fractionation occurred during sample combustion. However, no systematic dependence of Hg isotopic compositions on Hg recovery (81-102%) was observed. The tested 340 samples including coal, coal-associated rocks, fly ash, bottom ash, peat, and black shale sediments with Hg concentrations varying from <5 ng/g to 10 μg/g showed that most Hg recoveries were within the acceptable range of 80-120%. This protocol has the advantages of a short sample processing time (∼3.5 h) and limited transfer of residual sample matrix into the Hg trapping solution. This in turn limits matrix interferences on the Hg reduction efficiency of the cold vapor generator used for Hg isotopic analysis.
Fuller, Brian M; Ferguson, Ian T; Mohr, Nicholas M; Drewry, Anne M; Palmer, Christopher; Wessman, Brian T; Ablordeppey, Enyo; Keeperman, Jacob; Stephens, Robert J; Briscoe, Cristopher C; Kolomiets, Angelina A; Hotchkiss, Richard S; Kollef, Marin H
2017-09-01
We evaluated the efficacy of an emergency department (ED)-based lung-protective mechanical ventilation protocol for the prevention of pulmonary complications. This was a quasi-experimental, before-after study that consisted of a preintervention period, a run-in period of approximately 6 months, and a prospective intervention period. The intervention was a multifaceted ED-based mechanical ventilator protocol targeting lung-protective tidal volume, appropriate setting of positive end-expiratory pressure, rapid oxygen weaning, and head-of-bed elevation. A propensity score-matched analysis was used to evaluate the primary outcome, which was the composite incidence of acute respiratory distress syndrome and ventilator-associated conditions. A total of 1,192 patients in the preintervention group and 513 patients in the intervention group were included. Lung-protective ventilation increased by 48.4% in the intervention group. In the propensity score-matched analysis (n=490 in each group), the primary outcome occurred in 71 patients (14.5%) in the preintervention group compared with 36 patients (7.4%) in the intervention group (adjusted odds ratio 0.47; 95% confidence interval [CI] 0.31 to 0.71). There was an increase in ventilator-free days (mean difference 3.7; 95% CI 2.3 to 5.1), ICU-free days (mean difference 2.4; 95% CI 1.0 to 3.7), and hospital-free days (mean difference 2.4; 95% CI 1.2 to 3.6) associated with the intervention. The mortality rate was 34.1% in the preintervention group and 19.6% in the intervention group (adjusted odds ratio 0.47; 95% CI 0.35 to 0.63). Implementing a mechanical ventilator protocol in the ED is feasible and is associated with significant improvements in the delivery of safe mechanical ventilation and clinical outcome. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Wireless Energy Harvesting Two-Way Relay Networks with Hardware Impairments.
Peng, Chunling; Li, Fangwei; Liu, Huaping
2017-11-13
This paper considers a wireless energy harvesting two-way relay (TWR) network where the relay has energy-harvesting abilities and the effects of practical hardware impairments are taken into consideration. In particular, power splitting (PS) receiver is adopted at relay to harvests the power it needs for relaying the information between the source nodes from the signals transmitted by the source nodes, and hardware impairments is assumed suffered by each node. We analyze the effect of hardware impairments [-20]on both decode-and-forward (DF) relaying and amplify-and-forward (AF) relaying networks. By utilizing the obtained new expressions of signal-to-noise-plus-distortion ratios, the exact analytical expressions of the achievable sum rate and ergodic capacities for both DF and AF relaying protocols are derived. Additionally, the optimal power splitting (OPS) ratio that maximizes the instantaneous achievable sum rate is formulated and solved for both protocols. The performances of DF and AF protocols are evaluated via numerical results, which also show the effects of various network parameters on the system performance and on the OPS ratio design.
Control of size and aspect ratio in hydroquinone-based synthesis of gold nanorods
NASA Astrophysics Data System (ADS)
Morasso, Carlo; Picciolini, Silvia; Schiumarini, Domitilla; Mehn, Dora; Ojea-Jiménez, Isaac; Zanchetta, Giuliano; Vanna, Renzo; Bedoni, Marzia; Prosperi, Davide; Gramatica, Furio
2015-08-01
In this article, we describe how it is possible to tune the size and the aspect ratio of gold nanorods obtained using a highly efficient protocol based on the use of hydroquinone as a reducing agent by varying the amounts of CTAB and silver ions present in the "seed-growth" solution. Our approach not only allows us to prepare nanorods with a four times increased Au3+ reduction yield, when compared with the commonly used protocol based on ascorbic acid, but also allows a remarkable reduction of 50-60 % of the amount of CTAB needed. In fact, according to our findings, the concentration of CTAB present in the seed-growth solution do not linearly influence the final aspect ratio of the obtained nanorods, and an optimal concentration range between 30 and 50 mM has been identified as the one that is able to generate particles with more elongated shapes. On the optimized protocol, the effect of the concentration of Ag+ ions in the seed-growth solution and the stability of the obtained particles has also been investigated.
Yoo, Jae Ho; Lim, Bee Oh; Ha, Mina; Lee, Soo Won; Oh, Soo Jin; Lee, Yong Seuk; Kim, Jin Goo
2010-06-01
Female athletes are more prone to anterior cruciate ligament (ACL) injury than their male counterparts, presumably because of anatomical, hormonal, and neuromuscular differences. Of these three, only the neuromuscular component can be modified by preventive exercise. We aimed to evaluate the effect of a neuromuscular protocol on the prevention of ACL injury by performing meta-analysis, and to identify essential factors by subgroup analysis. An extensive literature review was conducted to identify relevant studies, and eventually, only seven randomized controlled trials or prospective cohort studies were included in the analysis. The odds ratios (OR) and the confidence interval (CI) for the overall effects of training and of potentially contributory factors were estimated. The OR and the 95% CI for the overall effect of the preventive training were 0.40 and [0.27, 0.60], respectively. Subgroup analysis revealed that an age under 18, soccer rather than handball, pre- and in-season training rather than either pre- or in-season training, and the plyometrics and strengthening components rather than balancing were significant. Meta-analysis showed that pre- and in-season neuromuscular training with an emphasis on plyometrics and strengthening exercises was effective at preventing ACL injury in female athletes, especially in those under 18 years of age. Further study is required to develop a relevant training program protocol of appropriate intensity.
Di Biase, Luigi; Gaita, Fiorenzo; Toso, Elisabetta; Santangeli, Pasquale; Mohanty, Prasant; Rutledge, Neal; Yan, Xue; Mohanty, Sanghamitra; Trivedi, Chintan; Bai, Rong; Price, Justin; Horton, Rodney; Gallinghouse, G Joseph; Beheiry, Salwa; Zagrodzky, Jason; Canby, Robert; Leclercq, Jean François; Halimi, Franck; Scaglione, Marco; Cesarani, Federico; Faletti, Riccardo; Sanchez, Javier; Burkhardt, J David; Natale, Andrea
2014-05-01
Silent cerebral ischemia (SCI) has been reported in 14% of cases after catheter ablation of atrial fibrillation (AF) with radiofrequency (RF) energy and discontinuation of warfarin before AF ablation procedures. The purpose of this study was to determine whether periprocedural anticoagulation management affects the incidence of SCI after RF ablation using an open irrigated catheter. Consecutive patients undergoing RF ablation for AF without warfarin discontinuation and receiving heparin bolus before transseptal catheterization (group I, n = 146) were compared with a group of patients who had protocol deviation in terms of maintaining the therapeutic preprocedural international normalized ratio (patients with subtherapeutic INR) and/or failure to receive pretransseptal heparin bolus infusion and/or ≥2 consecutive ACT measurements <300 seconds (noncompliant population, group II, n = 134) and with a group of patients undergoing RF ablation with warfarin discontinuation bridged with low molecular weight heparin (group III, n = 148). All patients underwent preablation and postablation (within 48 hours) diffusion magnetic resonance imaging. SCI was detected in 2% of patients (3/146) in group I, 7% (10/134) in group II, and 14% (21/148) in group III (P <.001). "Therapeutic INR" was strongly associated with a lower prevalence of postprocedural silent cerebral ischemia (SCI). Multivariable analysis demonstrated nonparoxysmal AF (odds ratio 3.8, 95% confidence interval 1.5-9.7, P = .005) and noncompliance to protocol (odds ratio 2.8, 95% confidence interval 1.5-5.1, P <.001] to be significant predictors of ischemic events. Strict adherence to an anticoagulation protocol significantly reduces the prevalence of SCI after catheter ablation of AF with RF energy. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Figueras, Francesc; Gratacos, Eduard; Rial, Marta; Gull, Ilan; Krofta, Ladislav; Lubusky, Marek; Rogelio, Cruz-Martinez; Mónica, Cruz-Lemini; Miguel, Martinez-Rodriguez; Socias, Pamela; Aleuanlli, Cristina; Cordero, Mauro C Parra
2017-01-01
Introduction Fetal growth restriction (FGR) affects 5%–10% of all pregnancies, contributing to 30%–50% of stillbirths. Unfortunately, growth restriction often is not detected antenatally. The last weeks of pregnancy are critical for preventing stillbirth among babies with FGR because there is a pronounced increase in stillbirths among growth-restricted fetuses after 37 weeks of pregnancy. Here we present a protocol (V.1, 23 May 2016) for the RATIO37 trial, which evaluates an integrated strategy for accurately selecting at-risk fetuses for delivery at term. The protocol is based on the combination of fetal biometry and cerebroplacental ratio (CPR). The primary objective is to reduce stillbirth rates. The secondary aims are to detect low birth weights and adverse perinatal outcomes. Methods and analysis The study is designed as multicentre (Spain, Chile, Mexico,Czech Republic and Israel), open-label, randomised trial with parallel groups. Singleton pregnancies will be invited to participate after routine second-trimester ultrasound scan (19+0–22+6 weeks of gestation), and participants will be randomly allocated to receive revealed or concealed CPR evaluation. Then, a routine ultrasound and Doppler scan will be performed at 36+0–37+6 weeks. Sociodemographic and clinical data will be collected at enrolment. Ultrasound and Doppler variables will be recorded at 36+0–37+6 weeks of pregnancy. Perinatal outcomes will be recorded after delivery. Univariate (with estimated effect size and its 95% CI) and multivariate (mixed-effects logistic regression) comparisons between groups will be performed. Ethics and dissemination The study will be conducted in accordance with the principles of Good Clinical Practice. This study was accepted by the Clinical Research Ethics Committee of Hospital Clinic Barcelona on 23May 2016. Subsequent approval by individual ethical committees and competent authorities was granted. The study results will be published in peer-reviewed journals and disseminated at international conferences. Trial registration number NCT02907242; pre-results. PMID:28619771
Suntharalingam, Saravanabavaan; Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael; Nassenstein, Kai
2017-01-01
To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; p<0.001). This 80 kVp standard pitch CTPA protocol with 25 ml contrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%.
Saade, Charbel; Mayat, Ahmad; El-Merhi, Fadi
2016-01-01
Matching contrast injection timing with vessel dynamics significantly improves vessel opacification and reduces contrast dose in the assessment of pulmonary embolism during computed tomography (CT) pulmonary angiography. The aim of this study was to investigate opacification of the pulmonary vasculature (PV) during CT pulmonary angiography using a patient-specific contrast formula (PSCF) and exponentially decelerated contrast media (EDCM) injection rate. Institutional review board approved this retrospective study. Computed tomography pulmonary angiography was performed on 200 patients with suspected pulmonary embolism using a 64-channel CT scanner. Patient demographics were equally distributed. Patients were randomly assigned to 2 equal protocol groups: protocol A used a PSCF, and protocol B involved the use of a PSCF combined with EDCM. The mean cross-sectional opacification profile of 8 central and 11 peripheral PVs were measured for each patient, and arteriovenous contrast ratio was calculated. Protocols were compared using Mann-Whitney U nonparametric statistics. Jackknife alternative free-response receiver operating characteristic analyses were used to assess diagnostic efficacy. Interobserver variations were investigated using kappa methods. A number of pulmonary arteries demonstrated increases in opacification (P < 0.02) for protocol B compared with A, whereas opacification in all veins was reduced in protocol B (P < 0.03). Subsequently, increased arteriovenous contrast ratio in protocol B compared with A was observed at all anatomic locations (P < 0.0002). An increase in jackknife alternative free-response receiver operating characteristic figure of merit (P < 0.0002) and interobserver variation was observed with protocol B compared with protocol A (κ = 0.3-0.73). Mean contrast volume was reduced in protocol B (29 [4] mL) compared with protocol A (33 [9] mL). Mean effective radiation dose in protocol B (1.2 [0.4] mSv) was reduced by 14% compared with protocol A (1.4 [0.6] mSv). Significant improvements in visualization of the PV can be achieved with a low contrast volume using an EDCM and PSCF. The reduced risk of cancer induction is highlighted.
Protocols for Automated Protist Analysis
2011-12-01
Report No: CG-D-14-13 Protocols for Automated Protist Analysis December 2011 Distribution Statement A: Approved for public...release; distribution is unlimited. Protocols for Automated Protist Analysis ii UNCLAS//Public | CG-926 RDC | B. Nelson, et al. | Public...Director United States Coast Guard Research & Development Center 1 Chelsea Street New London, CT 06320 Protocols for Automated Protist Analysis
Attitude determination for small satellites using GPS signal-to-noise ratio
NASA Astrophysics Data System (ADS)
Peters, Daniel
An embedded system for GPS-based attitude determination (AD) using signal-to-noise (SNR) measurements was developed for CubeSat applications. The design serves as an evaluation testbed for conducting ground based experiments using various computational methods and antenna types to determine the optimum AD accuracy. Raw GPS data is also stored to non-volatile memory for downloading and post analysis. Two low-power microcontrollers are used for processing and to display information on a graphic screen for real-time performance evaluations. A new parallel inter-processor communication protocol was developed that is faster and uses less power than existing standard protocols. A shorted annular patch (SAP) antenna was fabricated for the initial ground-based AD experiments with the testbed. Static AD estimations with RMS errors in the range of 2.5° to 4.8° were achieved over a range of off-zenith attitudes.
Zhang, Ying; Tobias, Herbert J; Brenna, J Thomas
2009-03-01
Carbon isotope ratio (CIR) analysis of urinary steroids using gas chromatography-combustion isotope ratio mass spectrometry (GCC-IRMS) is a recognized test to detect illicit doping with synthetic testosterone. There are currently no universally used steroid isotopic standards (SIS). We adapted a protocol to prepare isotopically uniform steroids for use as a calibrant in GCC-IRMS that can be analyzed under the same conditions as used for steroids extracted from urine. Two separate SIS containing a mixture of steroids were created and coded CU/USADA 33-1 and CU/USADA 34-1, containing acetates and native steroids, respectively. CU/USADA 33-1 contains 5alpha-androstan-3beta-ol acetate (5alpha-A-AC), 5alpha-androstan-3alpha-ol-17-one acetate (androsterone acetate, A-AC), 5beta-androstan-3alpha-ol-11, 17-dione acetate (11-ketoetiocholanolone acetate, 11k-AC) and 5alpha-cholestane (Cne). CU/USADA 34-1 contains 5beta-androstan-3alpha-ol-17-one (etiocholanolone, E), 5alpha-androstan-3alpha-ol-17-one (androsterone, A), and 5beta-pregnane-3alpha, 20alpha-diol (5betaP). Each mixture was prepared and dispensed into a set of about 100 ampoules using a protocol carefully designed to minimize isotopic fractionation and contamination. A natural gas reference material, NIST RM 8559, traceable to the international standard Vienna PeeDee Belemnite (VPDB) was used to calibrate the SIS. Absolute delta(13)C(VPDB) and Deltadelta(13)C(VPDB) values from randomly selected ampoules from both SIS indicate uniformity of steroid isotopic composition within measurement reproducibility, SD(delta(13)C)<0.2 per thousand. This procedure for creation of isotopic steroid mixtures results in consistent standards with isotope ratios traceable to the relevant international reference material.
Clemensson, Laura Emily; Fabry, Benedikt; Riess, Olaf; Nguyen, Huu Phuc
2017-01-01
Huntington disease is an inherited neurodegenerative disorder characterized by motor, cognitive, psychiatric and metabolic symptoms. We recently published a study describing that the BACHD rat model of HD shows an obesity phenotype, which might affect their motivation to perform food-based behavioral tests. Further, we argued that using a food restriction protocol based on matching BACHD and wild type rats’ food consumption rates might resolve these motivational differences. In the current study, we followed up on these ideas in a longitudinal study of the rats’ performance in a progressive ratio test. We also investigated the phenotype of reduced food consumption rate, which is typically seen in food-restricted BACHD rats, in greater detail. In line with our previous study, the BACHD rats were less motivated to perform the progressive ratio test compared to their wild type littermates, although the phenotype was no longer present when the rats’ food consumption rates had been matched. However, video analysis of food consumption tests suggested that the reduced consumption rate found in the BACHD rats was not entirely based on differences in hunger, but likely involved motoric impairments. Thus, restriction protocols based on food consumption rates are not appropriate when working with BACHD rats. As an alternative, we suggest that studies where BACHD rats are used should investigate how the readouts of interest are affected by motivational differences, and use appropriate control tests to avoid misleading results. In addition, we show that BACHD rats display distinct behavioral changes in their progressive ratio performance, which might be indicative of striatal dysfunction. PMID:28273120
Leverrier, Anthony; Grangier, Philippe
2009-05-08
We present a continuous-variable quantum key distribution protocol combining a discrete modulation and reverse reconciliation. This protocol is proven unconditionally secure and allows the distribution of secret keys over long distances, thanks to a reverse reconciliation scheme efficient at very low signal-to-noise ratio.
MAC Protocol for Ad Hoc Networks Using a Genetic Algorithm
Elizarraras, Omar; Panduro, Marco; Méndez, Aldo L.
2014-01-01
The problem of obtaining the transmission rate in an ad hoc network consists in adjusting the power of each node to ensure the signal to interference ratio (SIR) and the energy required to transmit from one node to another is obtained at the same time. Therefore, an optimal transmission rate for each node in a medium access control (MAC) protocol based on CSMA-CDMA (carrier sense multiple access-code division multiple access) for ad hoc networks can be obtained using evolutionary optimization. This work proposes a genetic algorithm for the transmission rate election considering a perfect power control, and our proposition achieves improvement of 10% compared with the scheme that handles the handshaking phase to adjust the transmission rate. Furthermore, this paper proposes a genetic algorithm that solves the problem of power combining, interference, data rate, and energy ensuring the signal to interference ratio in an ad hoc network. The result of the proposed genetic algorithm has a better performance (15%) compared to the CSMA-CDMA protocol without optimizing. Therefore, we show by simulation the effectiveness of the proposed protocol in terms of the throughput. PMID:25140339
Screening for Learning and Memory Mutations: A New Approach.
Gallistel, C R; King, A P; Daniel, A M; Freestone, D; Papachristos, E B; Balci, F; Kheifets, A; Zhang, J; Su, X; Schiff, G; Kourtev, H
2010-01-30
We describe a fully automated, live-in 24/7 test environment, with experimental protocols that measure the accuracy and precision with which mice match the ratio of their expected visit durations to the ratio of the incomes obtained from two hoppers, the progress of instrumental and classical conditioning (trials-to-acquisition), the accuracy and precision of interval timing, the effect of relative probability on the choice of a timed departure target, and the accuracy and precision of memory for the times of day at which food is available. The system is compact; it obviates the handling of the mice during testing; it requires negligible amounts of experimenter/technician time; and it delivers clear and extensive results from 3 protocols within a total of 7-9 days after the mice are placed in the test environment. Only a single 24-hour period is required for the completion of first protocol (the matching protocol), which is strong test of temporal and spatial estimation and memory mechanisms. Thus, the system permits the extensive screening of many mice in a short period of time and in limited space. The software is publicly available.
Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.
Schwindt, W; Kugel, H; Bachmann, R; Kloska, S; Allkemper, T; Maintz, D; Pfleiderer, B; Tombach, B; Heindel, W
2003-09-01
The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting.
Costa, Deena Kelly; Wallace, David J; Kahn, Jeremy M
2015-11-01
Daytime intensivist physician staffing is associated with improved outcomes in the ICU. However, it is unclear whether this association persists in the era of interprofessional, protocol-directed critical care. We sought to reexamine the association between daytime intensivist physician staffing and ICU mortality and determine if interprofessional rounding and protocols for mechanical ventilation in part mediate this relationship. Retrospective cohort study of ICUs in the Acute Physiology and Chronic Health Evaluation clinical information system from 2009 to 2010. Forty-nine ICUs in 25 U.S. hospitals. Adults (17 yr and older) admitted to a study ICU. None. We defined high-intensity daytime intensivist staffing as either a mandatory consult or closed ICU model; interprofessional rounds as rounds that included a respiratory therapist, pharmacist, physician and nurse; and protocol use as having protocols for liberation from mechanical ventilation and lung protective mechanical ventilation. Using multivariable logistic regression, we estimated the independent effect of daytime intensivist physician staffing on in-hospital mortality controlling for interprofessional rounds and protocols for mechanical ventilation, as well as other patient and hospital characteristics. Twenty-seven ICUs (55%) reported high-intensity daytime physician staffing, 42 ICUs (85%) reported daily interprofessional rounds, and 31 (63%) reported having protocols for mechanical ventilation. There was no association between daytime intensivist physician staffing and in-hospital mortality (adjusted odds ratio, 0.86; 95% CI, 0.65-1.14). After adjusting for interprofessional rounds and protocols for mechanical ventilation, the effect of daytime intensivist physician staffing remained nonsignificant (adjusted odds ratio, 0.90; 95% CI, 0.70-1.17). High-intensity daytime physician staffing in the ICU was not significantly associated with lower mortality in a modern cohort. This association was not affected by interprofessional rounds or protocols for mechanical ventilation.
Clark, Sean; Iltis, Peter W
2008-05-01
Controlled laboratory study. To compare postural performance measures of athletes with those of nonathletes when completing the standard Sensory Organization Test (SOT) and a modified SOT that included dynamic head tilts (DHT-SOT). Authors of recently published research have suggested that modifications to the SOT protocol (eg, introduction of pitch and roll head tilts) may enhance the test's sensitivity when assessing postural stability in individuals with higher balance capabilities or with well-compensated sensory deficits. Nineteen athletes and 19 nonathletes (group) completed both the SOT and DHT-SOT (protocol). During the SOT, participants stood upright as steadily as possible for 20 seconds during each of 6 different sensory conditions. As a variation of the SOT, the DHT-SOT incorporated active pitch and roll head tilts into the SOT protocol. Four 2-way mixed-model analyses of variance (with protocol as the repeated factor) were performed to determine if the composite equilibrium score or the visual, vestibular, or somatosensory ratio scores differed between the 2 groups across the 2 testing protocols. Significant group-by-protocol interaction effects were present for both the composite equilibrium score and visual ratio. Follow-up simple main-effects analyses indicated that these measures did not differ between groups for the SOT protocol but were significantly different on the DHT-SOT. The addition of dynamic head tilts to the SOT protocol resulted in subtle differences in balance function between athletes and nonathletes. Athletes demonstrated an increased ability to adapt to sensory disruptions during the DHT-SOT. Therapists should consider including active pitch and roll head tilts to the SOT when evaluating individuals with higher balance function or to detect subtle deficits in balance function. Diagnosis, level 3b.
The pharmacokinetics of commonly used antiepileptic drugs in immature CD1 mice
Markowitz, Geoffrey J.; Kadam, Shilpa D.; Boothe, Dawn M.; Irving, Natasha D.; Comi, Anne M.
2010-01-01
Rodents eliminate antiepileptic drugs (AEDs) faster than humans, creating challenges for designing clinically-relevant protocols. Half-lives of AEDs in immature mice are unknown. The pharmacokinetics of commonly-used AEDs were examined in CD1 mice using a single-dose protocol at post-natal day 19. Following intraperitoneal therapeutic dosing, blood serum concentrations spanning 1–48 hours post-administration and corresponding brain tissue concentrations at 4 hours were analyzed. Half-lives of valproate, phenobarbital, diazepam (and metabolites), phenytoin, and levetiracetam were 2.6, 15.8, 22.3, 16.3, and 3.2 hours respectively, compared to 0.8, 7.5, 7.7, 16.0, and 1.5 hours reported for adult mice. Brain-to-blood ratios were comparable to adult ratios. AEDs tested had longer half-lives and maintained therapeutic plasma concentrations longer than reported in mature mice, making clinically-relevant protocols feasible. PMID:20848732
Laurin, Nancy; Frégeau, Chantal
2012-01-01
The goal of this work was to optimize and validate a fast amplification protocol for the multiplex amplification of the STR loci included in AmpFlSTR(®) Profiler Plus(®) to expedite human DNA identification. By modifying the cycling conditions and by combining the use of a DNA polymerase optimized for high speed PCR (SpeedSTAR™ HS) and a more efficient thermal cycler instrument (Bio-RAD C1000™), we were able to reduce the amplification process from 4h to 26 min. No modification to the commercial AmpFlSTR(®) Profiler Plus(®) primer mix was required. When compared to the current Royal Canadian Mounted Police (RCMP) amplification protocol, no differences with regards to specificity, sensitivity, heterozygote peak height ratios and overall profile balance were noted. Moreover, complete concordance was obtained with profiles previously generated with the standard amplification protocol and minor alleles in mixture samples were reliably typed. An increase in n-4 stutter ratios (2.2% on average for all loci) was observed for profiles amplified with the fast protocol compared to the current procedure. Our results document the robustness of this rapid amplification protocol for STR profiling using the AmpFlSTR(®) Profiler Plus(®) primer set and demonstrate that comparable data can be obtained in substantially less time. This new approach could provide an alternative option to current multiplex STR typing amplification protocols in order to increase throughput or expedite time-sensitive cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Mhaskar, Rahul; Djulbegovic, Benjamin; Magazin, Anja; Soares, Heloisa P; Kumar, Ambuj
2012-06-01
To assess whether the reported methodological quality of randomized controlled trials (RCTs) reflects the actual methodological quality and to evaluate the association of effect size (ES) and sample size with methodological quality. Systematic review. This is a retrospective analysis of all consecutive phase III RCTs published by eight National Cancer Institute Cooperative Groups up to 2006. Data were extracted from protocols (actual quality) and publications (reported quality) for each study. Four hundred twenty-nine RCTs met the inclusion criteria. Overall reporting of methodological quality was poor and did not reflect the actual high methodological quality of RCTs. The results showed no association between sample size and actual methodological quality of a trial. Poor reporting of allocation concealment and blinding exaggerated the ES by 6% (ratio of hazard ratio [RHR]: 0.94; 95% confidence interval [CI]: 0.88, 0.99) and 24% (RHR: 1.24; 95% CI: 1.05, 1.43), respectively. However, actual quality assessment showed no association between ES and methodological quality. The largest study to date shows that poor quality of reporting does not reflect the actual high methodological quality. Assessment of the impact of quality on the ES based on reported quality can produce misleading results. Copyright © 2012 Elsevier Inc. All rights reserved.
Enhanced solid-phase recombinase polymerase amplification and electrochemical detection.
Del Río, Jonathan Sabaté; Lobato, Ivan Magriñà; Mayboroda, Olena; Katakis, Ioanis; O'Sullivan, Ciara K
2017-05-01
Recombinase polymerase amplification (RPA) is an elegant method for the rapid, isothermal amplification of nucleic acids. Here, we elucidate the optimal surface chemistry for rapid and efficient solid-phase RPA, which was fine-tuned in order to obtain a maximum signal-to-noise ratio, defining the optimal DNA probe density, probe-to-lateral spacer ratio (1:0, 1:1, 1:10 and 1:100) and length of a vertical spacer of the probe as well as investigating the effect of different types of lateral spacers. The use of different labelling strategies was also examined in order to reduce the number of steps required for the analysis, using biotin or horseradish peroxidase-labelled reverse primers. Optimisation of the amplification temperature used and the use of surface blocking agents were also pursued. The combination of these changes facilitated a significantly more rapid amplification and detection protocol, with a lowered limit of detection (LOD) of 1 · 10 -15 M. The optimised protocol was applied to the detection of Francisella tularensis in real samples from hares and a clear correlation with PCR and qPCR results observed and the solid-phase RPA demonstrated to be capable of detecting 500 fM target DNA in real samples. Graphical abstract Relative size of thiolated lateral spacers tested versus the primer and the uvsx recombinase protein.
Mangold, Stefanie; De Cecco, Carlo N; Wichmann, Julian L; Canstein, Christian; Varga-Szemes, Akos; Caruso, Damiano; Fuller, Stephen R; Bamberg, Fabian; Nikolaou, Konstantin; Schoepf, U Joseph
2016-05-01
To compare, on an intra-individual basis, the effect of automated tube voltage selection (ATVS), integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of aortic CTA studies using 2nd and 3rd generation dual-source CT (DSCT). We retrospectively evaluated 32 patients who had undergone CTA of the entire aorta with both 2nd generation DSCT at 120kV using filtered back projection (FBP) (protocol 1) and 3rd generation DSCT using ATVS, an integrated circuit detector and advanced iterative reconstruction (protocol 2). Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using a five-point scale. Radiation dose parameters were recorded. All studies were considered of diagnostic image quality. CNR was significantly higher with protocol 2 (15.0±5.2 vs 11.0±4.2; p<.0001). Subjective image quality analysis revealed no significant differences for evaluation of attenuation (p=0.08501) but image noise was rated significantly lower with protocol 2 (p=0.0005). Mean tube voltage and effective dose were 94.7±14.1kV and 6.7±3.9mSv with protocol 2; 120±0kV and 11.5±5.2mSv with protocol 1 (p<0.0001, respectively). Aortic CTA performed with 3rd generation DSCT, ATVS, integrated circuit detector, and advanced iterative reconstruction allow a substantial reduction of radiation exposure while improving image quality in comparison to 120kV imaging with FBP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kortz, Teresa Bleakly; Axelrod, David M; Chisti, Mohammod J; Kache, Saraswati
2017-01-01
Pediatric sepsis has a high mortality rate in limited resource settings. Sepsis protocols have been shown to be a cost-effective strategy to improve morbidity and mortality in a variety of populations and settings. At Dhaka Hospital in Bangladesh, mortality from pediatric sepsis in high-risk children previously approached 60%, which prompted the implementation of an evidenced-based protocol in 2010. The clinical effectiveness of this protocol had not been measured. We hypothesized that implementation of a pediatric sepsis protocol improved clinical outcomes, including reducing mortality and length of hospital stay. This was a retrospective cohort study of children 1-59 months old with a diagnosis of sepsis, severe sepsis or septic shock admitted to Dhaka Hospital from 10/25/2009-10/25/2011. The primary outcome was inpatient mortality pre- and post-protocol implementation. Secondary outcomes included fluid overload, heart failure, respiratory insufficiency, length of hospital stay, and protocol compliance, as measured by antibiotic and fluid bolus administration within 60 minutes of hospital presentation. 404 patients were identified by a key-word search of the electronic medical record; 328 patients with a primary diagnosis of sepsis, severe sepsis, or septic shock were included (143 pre- and185 post-protocol) in the analysis. Pre- and post-protocol mortality were similar and not statistically significant (32.17% vs. 34.59%, p = 0.72). The adjusted odds ratio (AOR) for post-protocol mortality was 1.55 (95% CI, 0.88-2.71). The odds for developing fluid overload were significantly higher post-protocol (AOR 3.45, 95% CI, 2.04-5.85), as were the odds of developing heart failure (AOR 4.52, 95% CI, 1.43-14.29) and having a longer median length of stay (AOR 1.81, 95% CI 1.10-2.96). There was no statistically significant difference in respiratory insufficiency (pre- 65.7% vs. post- 70.3%, p = 0.4) or antibiotic administration between the cohorts (pre- 16.08% vs. post- 12.43%, p = 0.42). Implementation of a pediatric sepsis protocol did not improve all-cause mortality or length of stay and may have been associated with increased fluid overload and heart failure during the study period in a large, non-governmental hospital in Bangladesh. Similar rates of early antibiotic administration may indicate poor protocol compliance. Though evidenced-based protocols are a potential cost-effective strategy to improve outcomes, future studies should focus on optimal implementation of context-relevant sepsis protocols in limited resource settings.
Strategies for Optimal MAC Parameters Tuning in IEEE 802.15.6 Wearable Wireless Sensor Networks.
Alam, Muhammad Mahtab; Ben Hamida, Elyes
2015-09-01
Wireless body area networks (WBAN) has penetrated immensely in revolutionizing the classical heath-care system. Recently, number of WBAN applications has emerged which introduce potential limits to existing solutions. In particular, IEEE 802.15.6 standard has provided great flexibility, provisions and capabilities to deal emerging applications. In this paper, we investigate the application-specific throughput analysis by fine-tuning the physical (PHY) and medium access control (MAC) parameters of the IEEE 802.15.6 standard. Based on PHY characterizations in narrow band, at the MAC layer, carrier sense multiple access collision avoidance (CSMA/CA) and scheduled access protocols are extensively analyzed. It is concluded that, IEEE 802.15.6 standard can satisfy most of the WBANs applications throughput requirements by maximum achieving 680 Kbps. However, those emerging applications which require high quality audio or video transmissions, standard is not able to meet their constraints. Moreover, delay, energy efficiency and successful packet reception are considered as key performance metrics for comparing the MAC protocols. CSMA/CA protocol provides the best results to meet the delay constraints of medical and non-medical WBAN applications. Whereas, the scheduled access approach, performs very well both in energy efficiency and packet reception ratio.
Cho, S H; Lowenstein, J R; Balter, P A; Wells, N H; Hanson, W F
2000-01-01
A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosimetry based on TG-51 may be somewhat different from those based on TG-21. The Radiological Physics Center has conducted a systematic comparison between the two protocols, in which photon and electron beam outputs following both protocols were compared under identical conditions. Cylindrical chambers used in this study were selected from the list given in the TG-51 report, covering the majority of current manufacturers. Measured ratios between absorbed-dose and air-kerma calibration factors, derived from the standards traceable to the NIST, were compared with calculated values using the TG-21 protocol. The comparison suggests that there is roughly a 1% discrepancy between measured and calculated ratios. This discrepancy may provide a reasonable measure of possible changes between the absorbed-dose to water determined by TG-51 and that determined by TG-21 for photon beam calibrations. The typical change in a 6 MV photon beam calibration following the implementation of the TG-51 protocol was about 1%, regardless of the chamber used, and the change was somewhat smaller for an 18 MV photon beam. On the other hand, the results for 9 and 16 MeV electron beams show larger changes up to 2%, perhaps because of the updated electron stopping power data used for the TG-51 protocol, in addition to the inherent 1% discrepancy presented in the calibration factors. The results also indicate that the changes may be dependent on the electron energy.
Measurement of fecal elastase improves performance of newborn screening for cystic fibrosis.
Barben, Juerg; Rueegg, Corina S; Jurca, Maja; Spalinger, Johannes; Kuehni, Claudia E
2016-05-01
The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Mutz, M; Boudreaux, B; Kearney, M; Stroda, K; Gaunt, S; Shiomitsu, K
2015-12-01
Canine multi-centric B-cell lymphoma shares similarities with diffuse large B-cell (Non-Hodgkin's) lymphoma (NHL) in people. In people with NHL, lymphopenia at diagnosis and first relapse and neutrophil/lymphocyte ratio (N:L) > 3.5 are negative prognostic factors for survival. The objective of this study was to determine if lymphocyte concentration at diagnosis and first relapse and N:L were prognostic for survival in dogs with newly diagnosed multi-centric lymphoma. Medical records of 77 dogs with multi-centric lymphoma treated with a CHOP-based chemotherapy protocol were retrospectively evaluated. Absolute lymphocyte concentration and N:L ratio at presentation of dogs pre-treated with steroids was not significantly different from dogs who had not received steroids. On multivariate analysis, only immunophenotype remained significant for progression-free survival (PFS), whereas no variables remained significant for ST. A prospective study of these haematologic variables is warranted to assess their true significance. © 2013 John Wiley & Sons Ltd.
Traffic noise analysis protocol for new highway construction and reconstruction projects.
DOT National Transportation Integrated Search
1998-10-01
The Traffic Noise Analysis Protocol (hereafter referred to as the Protocol) : contains Caltrans noise policies, which fulfill the highway noise analysis and : abatement/mitigation requirements stemming from the following State and : Federal environme...
Protocol vulnerability detection based on network traffic analysis and binary reverse engineering.
Wen, Shameng; Meng, Qingkun; Feng, Chao; Tang, Chaojing
2017-01-01
Network protocol vulnerability detection plays an important role in many domains, including protocol security analysis, application security, and network intrusion detection. In this study, by analyzing the general fuzzing method of network protocols, we propose a novel approach that combines network traffic analysis with the binary reverse engineering method. For network traffic analysis, the block-based protocol description language is introduced to construct test scripts, while the binary reverse engineering method employs the genetic algorithm with a fitness function designed to focus on code coverage. This combination leads to a substantial improvement in fuzz testing for network protocols. We build a prototype system and use it to test several real-world network protocol implementations. The experimental results show that the proposed approach detects vulnerabilities more efficiently and effectively than general fuzzing methods such as SPIKE.
Marcuzzo, Stefania; Bonanno, Silvia; Padelli, Francesco; Moreno-Manzano, Victoria; García-Verdugo, José Manuel; Bernasconi, Pia; Mantegazza, Renato; Bruzzone, Maria Grazia; Zucca, Ileana
2016-01-01
Diffusion-weighted Magnetic Resonance Imaging (dMRI) has relevant applications in the microstructural characterization of the spinal cord, especially in neurodegenerative diseases. Animal models have a pivotal role in the study of such diseases; however, in vivo spinal dMRI of small animals entails additional challenges that require a systematical investigation of acquisition parameters. The purpose of this study is to compare three acquisition protocols and identify the scanning parameters allowing a robust estimation of the main diffusion quantities and a good sensitivity to neurodegeneration in the mouse spinal cord. For all the protocols, the signal-to-noise and contrast-to noise ratios and the mean value and variability of Diffusion Tensor metrics were evaluated in healthy controls. For the estimation of fractional anisotropy less variability was provided by protocols with more diffusion directions, for the estimation of mean, axial and radial diffusivity by protocols with fewer diffusion directions and higher diffusion weighting. Intermediate features (12 directions, b = 1200 s/mm2) provided the overall minimum inter- and intra-subject variability in most cases. In order to test the diagnostic sensitivity of the protocols, 7 G93A-SOD1 mice (model of amyotrophic lateral sclerosis) at 10 and 17 weeks of age were scanned and the derived diffusion parameters compared with those estimated in age-matched healthy animals. The protocols with an intermediate or high number of diffusion directions provided the best differentiation between the two groups at week 17, whereas only few local significant differences were highlighted at week 10. According to our results, a dMRI protocol with an intermediate number of diffusion gradient directions and a relatively high diffusion weighting is optimal for spinal cord imaging. Further work is needed to confirm these results and for a finer tuning of acquisition parameters. Nevertheless, our findings could be important for the optimization of acquisition protocols for preclinical and clinical dMRI studies on the spinal cord. PMID:27560686
Seagle, Brandon-Luke L; Shahabi, Shohreh
2017-04-01
To determine the cost-effectiveness of dose-dense versus standard intravenous adjuvant chemotherapy for ovarian cancer using results from the no-bevacizumab cohort of the Gynecologic Oncology Group protocol 262 (GOG-262) randomized controlled trial, which reported a smaller absolute progression-free survival (PFS) benefit than the prior Japanese trial. A three-state Markov decision model from a healthcare system perspective with a 21day cycle length and 28month time-horizon was used to calculate incremental cost-effectiveness ratio (ICER) values per progression-free life-year saved (PFLYS) using results from GOG-262. Costs of chemotherapy, complications, and surveillance were from Medicare or institutional data. PFS, discontinuation, and complication rates were from GOG-262. Time-dependent transition probabilities and within-cycle corrections were used. One-way and probabilistic sensitivity analyses were performed. The model produces standard and dose-dense cohorts with 84.3% and 68.3% progression event proportions at 28months, matching GOG-262 rates at the trial's median follow-up. With a median PFS of 10.3months after standard chemotherapy and a hazard ratio for progression of 0.62 after dose-dense therapy, the ICER for dose-dense chemotherapy is $8074.25 (95% confidence interval: $7615.97-$10,207.16) per PFLYS. ICER estimates are sensitive only to the hazard ratio estimate but do not exceed $100,000 per PFLYS. 99.8% of ICER estimates met a more stringent willingness-to-pay of $50,000 per PFLYS. The willingness-to-pay value at which there is a 90% probability of dose-dense treatment being cost-effective is $12,000 per PFLYS. Dose-dense adjuvant chemotherapy is robustly cost-effective for advanced ovarian cancer from a healthcare system perspective based on results from GOG-262. Copyright © 2017 Elsevier Inc. All rights reserved.
Lishman, Hannah; Aylin, Paul; Alividza, Vivian; Castro-Sanchez, Enrique; Chatterjee, Anuja; Mariano, Victor; Johnson, Alan P; Jeraj, Samir; Costelloe, Céire
2017-12-11
Antibiotic resistance (ABR) is an urgent problem globally, with overuse and misuse of antibiotics being one of the main drivers of antibiotic-resistant infections. There is increasing evidence that the burden of community-acquired infections such as urinary tract infections and bloodstream infections (both susceptible and resistant) may differ by ethnicity, although the reasons behind this relationship are not well defined. It has been demonstrated that socioeconomic status and ethnicity are often highly correlated with each other; however, it is not yet known whether accounting for deprivation completely explains any discrepancy seen in infection risk. There have currently been no systematic reviews summarising the evidence for the relationship between ethnicity and antibiotic resistance or prescribing. This protocol will outline how we will conduct this systematic literature review and meta-analysis investigating whether there is an association between patient ethnicity and (1) risk of antibiotic-resistant infections or (2) levels of antibiotic prescribing in high-income countries. We will search PubMed/MEDLINE, EMBASE, Global Health, Scopus and CINAHL using MESH terms where applicable. Two reviewers will conduct title/abstract screening, data extraction and quality assessment independently. The Critical Appraisal Skills Programme (CASP) checklist will be used for cohort and case-control studies, and the Cochrane collaboration's risk of bias tool will be used for randomised control trials, if they are included. Meta-analyses will be performed by calculating the minority ethnic group to majority ethnic group odds ratios or risk ratios for each study and presenting an overall pooled odds ratio for the two outcomes. The Grading of Recommendations, Assessments, Development and Evaluation (GRADE) approach will be used to assess the overall quality of the body of evidence. In this systematic review and meta-analysis, we will aim to collate the available evidence of whether there is a difference in rates of AMR and/or antibiotic prescribing in minority vs. majority ethnic groups in high-income countries. Additionally, this review will highlight areas where more research needs to be conducted and may provide insight into what may cause differences in this relationship, should they be seen. PROSPERO ( CRD42016051533 ).
Hillard, Brent; El-Baz, Ayman S; Sears, Lonnie; Tasman, Allan; Sokhadze, Estate M
2013-07-01
Neurofeedback is a nonpharmacological treatment for attention-deficit hyperactivity disorder (ADHD). We propose that operant conditioning of electroencephalogram (EEG) in neurofeedback training aimed to mitigate inattention and low arousal in ADHD, will be accompanied by changes in EEG bands' relative power. Patients were 18 children diagnosed with ADHD. The neurofeedback protocol ("Focus/Alertness" by Peak Achievement Trainer) has a focused attention and alertness training mode. The neurofeedback protocol provides one for Focus and one for Alertness. This does not allow for collecting information regarding changes in specific EEG bands (delta, theta, alpha, low and high beta, and gamma) power within the 2 to 45 Hz range. Quantitative EEG analysis was completed on each of twelve 25-minute-long sessions using a custom-made MatLab application to determine the relative power of each of the aforementioned EEG bands throughout each session, and from the first session to the last session. Additional statistical analysis determined significant changes in relative power within sessions (from minute 1 to minute 25) and between sessions (from session 1 to session 12). Analysis was of relative power of theta, alpha, low and high beta, theta/alpha, theta/beta, and theta/low beta and theta/high beta ratios. Additional secondary measures of patients' post-neurofeedback outcomes were assessed, using an audiovisual selective attention test (IVA + Plus) and behavioral evaluation scores from the Aberrant Behavior Checklist. Analysis of data computed in the MatLab application, determined that theta/low beta and theta/alpha ratios decreased significantly from session 1 to session 12, and from minute 1 to minute 25 within sessions. The findings regarding EEG changes resulting from brain wave self-regulation training, along with behavioral evaluations, will help elucidate neural mechanisms of neurofeedback aimed to improve focused attention and alertness in ADHD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gingold, E; Dave, J
2014-06-01
Purpose: The purpose of this study was to compare a new model-based iterative reconstruction with existing reconstruction methods (filtered backprojection and basic iterative reconstruction) using quantitative analysis of standard image quality phantom images. Methods: An ACR accreditation phantom (Gammex 464) and a CATPHAN600 phantom were scanned using 3 routine clinical acquisition protocols (adult axial brain, adult abdomen, and pediatric abdomen) on a Philips iCT system. Each scan was acquired using default conditions and 75%, 50% and 25% dose levels. Images were reconstructed using standard filtered backprojection (FBP), conventional iterative reconstruction (iDose4) and a prototype model-based iterative reconstruction (IMR). Phantom measurementsmore » included CT number accuracy, contrast to noise ratio (CNR), modulation transfer function (MTF), low contrast detectability (LCD), and noise power spectrum (NPS). Results: The choice of reconstruction method had no effect on CT number accuracy, or MTF (p<0.01). The CNR of a 6 HU contrast target was improved by 1–67% with iDose4 relative to FBP, while IMR improved CNR by 145–367% across all protocols and dose levels. Within each scan protocol, the CNR improvement from IMR vs FBP showed a general trend of greater improvement at lower dose levels. NPS magnitude was greatest for FBP and lowest for IMR. The NPS of the IMR reconstruction showed a pronounced decrease with increasing spatial frequency, consistent with the unusual noise texture seen in IMR images. Conclusion: Iterative Model Reconstruction reduces noise and improves contrast-to-noise ratio without sacrificing spatial resolution in CT phantom images. This offers the possibility of radiation dose reduction and improved low contrast detectability compared with filtered backprojection or conventional iterative reconstruction.« less
Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael
2017-01-01
Objectives To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Materials and methods Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. Results There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; p<0.001). Conclusions This 80 kVp standard pitch CTPA protocol with 25 ml contrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%. PMID:29045463
Sun, Changling; Zhang, Yayun; Han, Xue; Du, Xiaodong
2018-03-01
Objective The purposes of this study were to verify the effectiveness of the narrow band imaging (NBI) system in diagnosing nasopharyngeal cancer (NPC) as compared with white light endoscopy. Data Sources PubMed, Cochrane Library, EMBASE, CNKI, and Wan Fang databases. Review Methods Data analyses were performed with Meta-Disc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with a Deeks asymmetry test. The registry number of the protocol published on PROSPERO is CRD42015026244. Results This meta-analysis included 10 studies of 1337 lesions. For NBI diagnosis of NPC, the pooled values were as follows: sensitivity, 0.83 (95% CI, 0.80-0.86); specificity, 0.91 (95% CI, 0.89-0.93); positive likelihood ratio, 8.82 (95% CI, 5.12-15.21); negative likelihood ratio, 0.18 (95% CI, 0.12-0.27); and diagnostic odds ratio, 65.73 (95% CI, 36.74-117.60). The area under the curve was 0.9549. For white light endoscopy in diagnosing NPC, the pooled values were as follows: sensitivity, 0.79 (95% CI, 0.75-0.83); specificity, 0.87 (95% CI, 0.84-0.90); positive likelihood ratio, 5.02 (95% CI, 1.99-12.65); negative likelihood ratio, 0.34 (95% CI, 0.24-0.49); and diagnostic odds ratio, 16.89 (95% CI, 5.98-47.66). The area under the curve was 0.8627. The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 0.326. No marked publication bias ( P = .68) existed in this meta-analysis. Conclusion The sensitivity and specificity of NBI for the diagnosis of NPC are similar to those of white light endoscopy, and the potential value of NBI for the diagnosis of NPC needs to be validated further.
Martelat, Benoit; Isnard, Helene; Vio, Laurent; Dupuis, Erwan; Cornet, Terence; Nonell, Anthony; Chartier, Frederic
2018-06-22
Precise isotopic and elemental characterization of spent nuclear fuel is a major concern for the validation of the neutronic calculation codes and waste management strategy in the nuclear industry. Generally, the elements of interest, particularly U and Pu which are the two major elements present in spent fuel, are purified by ion exchange or extractant resins before off-line measurements by thermal ionization mass spectrometry. The aim of the present work was to develop a new analytical approach based on capillary electrophoresis (CE) hyphenated to a multicollector inductively coupled plasma mass spectrometer (MC-ICPMS) for online isotope ratio measurements. An electrophoretic separation protocol of U, Pu and the fraction containing fission products and minor actinides (Am and Cm) was developed using acetic acid as the electrolyte and complexing agent. The instrumentation for CE was designed to be used in a glove box and a laboratory-built interface was developed for hyphenation with MC-ICPMS. The separation was realized with only a few nL of a solution of spent nuclear fuel and the reproducibilities obtained on the U and Pu isotope ratios were on the order of a few ‰ which is comparable to those obtained by thermal ionization mass spectrometer (TIMS). This innovative protocol allowed a tremendous reduction of the analyte masses from μg to ng and also a drastic reduction of the liquid waste production from mL to μL. In addition, the time of analysis was shorted by at least a factor three. All of these improved parameters are of major interest for nuclear applications.
Londra, Laura; Moreau, Caroline; Strobino, Donna; Bhasin, Aarti; Zhao, Yulian
2016-09-01
To evaluate the association between different ovarian hyperstimulation protocols and ectopic pregnancy (EP) in in vitro fertilization (IVF) cycles in fresh autologous embryo transfer cycles in the United States between 2008 and 2011 as reported to the Society of Assisted Reproductive Technology (SART). Historical cohort study. Not applicable. None. None. All autologous cycles that resulted in a clinical pregnancy after a fresh, intrauterine embryo transfer and described characteristics of cycles according to protocol were included: luteal GnRH agonist, GnRH agonist flare, or GnRH antagonist. Multivariate logistic regression was conducted to investigate the association between type of protocol and EP. Among 136,605 clinical pregnancies, 2,645 (1.94%) were EP. Ectopic pregnancy was more frequent with GnRH antagonist (2.4%) cycles than with GnRH agonist flare (2.1%) or luteal GnRH agonist (1.6%) cycles. After adjusting for maternal and treatment characteristics, the GnRH antagonist and the GnRH agonist flare protocols were associated with increased odds of EP (adjusted odds ratio [aOR] 1.52; 95% confidence interval [CI], 1.39-1.65; and aOR 1.25; 95% CI, 1.09-1.44, respectively) compared with luteal GnRH agonist. Analysis of differences in the factors related to EP in luteal GnRH agonist versus GnRH antagonist protocols indicated that diminished ovarian reserve was associated with an increased risk of EP in luteal GnRH agonist but not in GnRH antagonist cycles. The type of protocol used during ovarian hyperstimulation in fresh autologous cycles was associated with EP. This finding suggests a role for extrapituitary GnRH on the tubal and uterine environment during ovarian hyperstimulation treatment for IVF. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Monitoring fish distributions along electrofishing segments
Miranda, Leandro E.
2014-01-01
Electrofishing is widely used to monitor fish species composition and relative abundance in streams and lakes. According to standard protocols, multiple segments are selected in a body of water to monitor population relative abundance as the ratio of total catch to total sampling effort. The standard protocol provides an assessment of fish distribution at a macrohabitat scale among segments, but not within segments. An ancillary protocol was developed for assessing fish distribution at a finer scale within electrofishing segments. The ancillary protocol was used to estimate spacing, dispersion, and association of two species along shore segments in two local reservoirs. The added information provided by the ancillary protocol may be useful for assessing fish distribution relative to fish of the same species, to fish of different species, and to environmental or habitat characteristics.
Zendehdel, Manoosh; Niakan, Babak; Keshtkar, Abbasali; Rafiei, Elahe; Salamat, Fatemeh
2018-01-01
Breast cancer is a multifactorial disease. Benign breast disease (BBD) is one of the most important risk factors for breast cancer. The etiology of BBD is unknown. It is divided into nonproliferative and proliferative diseases. The selection of studies will be based on titles, abstract screening, inclusion and exclusion criteria, and quality assessment. Previous studies have shown that all types of BBD increase the risk of breast cancer, but the risk degree is different for each one. Accurate risk estimation of breast cancer in each category can be very important for proper clinical management. This systematic review and meta-analysis will be conducted on observational studies (traditional case control, nested case control, case cohort, and cohort) published in the Web of Science (ISI), PubMed (MEDLINE), Scopus, Google Scholar, and the key journals of this field such as Breast Cancer Research and Treatment and Cancer Research from January 2000 to June 2015. Reference lists and gray literature will be reviewed too. All the initial retrievals will be performed by 2 researchers independently. The data extraction form will consist of general information concerning the studies, study eligibility, method, risk of bias assessment, and results—including odds ratios, risk ratios, rate ratios, and hazard ratios. The PRISMA and MOOSE guidelines will be used to report our findings. Registration Details: PROSPERO-42016035243 PMID:29398746
Zendehdel, Manoosh; Niakan, Babak; Keshtkar, Abbasali; Rafiei, Elahe; Salamat, Fatemeh
2018-01-01
Breast cancer is a multifactorial disease. Benign breast disease (BBD) is one of the most important risk factors for breast cancer. The etiology of BBD is unknown. It is divided into nonproliferative and proliferative diseases. The selection of studies will be based on titles, abstract screening, inclusion and exclusion criteria, and quality assessment. Previous studies have shown that all types of BBD increase the risk of breast cancer, but the risk degree is different for each one. Accurate risk estimation of breast cancer in each category can be very important for proper clinical management. This systematic review and meta-analysis will be conducted on observational studies (traditional case control, nested case control, case cohort, and cohort) published in the Web of Science (ISI), PubMed (MEDLINE), Scopus, Google Scholar, and the key journals of this field such as Breast Cancer Research and Treatment and Cancer Research from January 2000 to June 2015. Reference lists and gray literature will be reviewed too. All the initial retrievals will be performed by 2 researchers independently. The data extraction form will consist of general information concerning the studies, study eligibility, method, risk of bias assessment, and results-including odds ratios, risk ratios, rate ratios, and hazard ratios. The PRISMA and MOOSE guidelines will be used to report our findings. Registration Details: PROSPERO-42016035243.
A two-hop based adaptive routing protocol for real-time wireless sensor networks.
Rachamalla, Sandhya; Kancherla, Anitha Sheela
2016-01-01
One of the most important and challenging issues in wireless sensor networks (WSNs) is to optimally manage the limited energy of nodes without degrading the routing efficiency. In this paper, we propose an energy-efficient adaptive routing mechanism for WSNs, which saves energy of nodes by removing the much delayed packets without degrading the real-time performance of the used routing protocol. It uses the adaptive transmission power algorithm which is based on the attenuation of the wireless link to improve the energy efficiency. The proposed routing mechanism can be associated with any geographic routing protocol and its performance is evaluated by integrating with the well known two-hop based real-time routing protocol, PATH and the resulting protocol is energy-efficient adaptive routing protocol (EE-ARP). The EE-ARP performs well in terms of energy consumption, deadline miss ratio, packet drop and end-to-end delay.
Feasibility of Developing a Protocol for Automated Protist Analysis
2010-03-01
Acquisition Directorate Research & Development Center Report No: CG-D-02-ll Feasibility of Developing a Protocol for Automated Protist Analysis...Technical Information Service, Springfield, VA 22161. March 2010 Homeland Security Feasibility of Developing a Protocol for Automated Protist ...March 21)10 Feasibility of Developing a Protocol for Automated Protist Analysis 00 00 o CM Technical Report Documentation Page 1. Report No CG-D
NASA Technical Reports Server (NTRS)
Mueller, J. L. (Editor); Fargion, Giuletta S. (Editor); McClain, Charles R. (Editor); Pegau, Scott; Zaneveld, J. Ronald V.; Mitchell, B. Gregg; Kahru, Mati; Wieland, John; Stramska, Malgorzat
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.
NASA Technical Reports Server (NTRS)
Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.
Screening for Learning and Memory Mutations: A New Approach
Gallistel, C. R.; King, A. P.; Daniel, A. M.; Freestone, D.; Papachristos, E. B.; Balci, F.; Kheifets, A.; Zhang, J.; Su, X.; Schiff, G.; Kourtev, H.
2010-01-01
We describe a fully automated, live-in 24/7 test environment, with experimental protocols that measure the accuracy and precision with which mice match the ratio of their expected visit durations to the ratio of the incomes obtained from two hoppers, the progress of instrumental and classical conditioning (trials-to-acquisition), the accuracy and precision of interval timing, the effect of relative probability on the choice of a timed departure target, and the accuracy and precision of memory for the times of day at which food is available. The system is compact; it obviates the handling of the mice during testing; it requires negligible amounts of experimenter/technician time; and it delivers clear and extensive results from 3 protocols within a total of 7–9 days after the mice are placed in the test environment. Only a single 24-hour period is required for the completion of first protocol (the matching protocol), which is strong test of temporal and spatial estimation and memory mechanisms. Thus, the system permits the extensive screening of many mice in a short period of time and in limited space. The software is publicly available. PMID:20352069
Evaluation of a continuous-rotation, high-speed scanning protocol for micro-computed tomography.
Kerl, Hans Ulrich; Isaza, Cristina T; Boll, Hanne; Schambach, Sebastian J; Nolte, Ingo S; Groden, Christoph; Brockmann, Marc A
2011-01-01
Micro-computed tomography is used frequently in preclinical in vivo research. Limiting factors are radiation dose and long scan times. The purpose of the study was to compare a standard step-and-shoot to a continuous-rotation, high-speed scanning protocol. Micro-computed tomography of a lead grid phantom and a rat femur was performed using a step-and-shoot and a continuous-rotation protocol. Detail discriminability and image quality were assessed by 3 radiologists. The signal-to-noise ratio and the modulation transfer function were calculated, and volumetric analyses of the femur were performed. The radiation dose of the scan protocols was measured using thermoluminescence dosimeters. The 40-second continuous-rotation protocol allowed a detail discriminability comparable to the step-and-shoot protocol at significantly lower radiation doses. No marked differences in volumetric or qualitative analyses were observed. Continuous-rotation micro-computed tomography significantly reduces scanning time and radiation dose without relevantly reducing image quality compared with a normal step-and-shoot protocol.
Chian, Teo Chee; Nassir, Norziana Mat; Ibrahim, Mohd Izuan; Yusof, Ahmad Khairuddin Md; Sabarudin, Akmal
2017-02-01
This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.
Kamei, Daigo; Moriyama, Takahito; Takei, Takashi; Wakai, Sachiko; Nitta, Kosaku
2014-04-01
In recent years, tonsillectomy and steroid pulse (TSP) therapy have been widely performed in Japan. However, there is no consensus about the treatment protocol and indication. In this retrospective analysis, we compared patients who received tonsillectomy plus intermittent steroid pulse (SP) therapy three times in 6 months (ISP group, n = 44) with patients who received tonsillectomy plus 3 weeks of consecutive SP therapy (CSP group, n = 46) within 1 year after renal biopsy. These two different protocols were performed at two different institutions. We analyzed the clinical and histological background and clinical remission (CR), defined as disappearance of urine abnormalities at 18 months after starting treatment. Before treatment, there was no significant difference in the clinical findings except for sex between the two groups. In ISP group and CSP group, mean estimated glomerular filtration rate was 82.1 ± 20.9 and 85.9 ± 19.1 ml/min/1.73 m(2), median proteinuria was 0.55 and 0.56 g/day, and median urinary red blood cells were 20 (10-20) and 20 (6-30)/high power filed. The histological (H) grade was lower in the CSP than the ISP group (p = 0.022). The remission rate of proteinuria, hematuria, and rate of CR by the Kaplan-Meier method and logrank test were significantly higher in the CSP group than in the ISP group (CSP vs. ISP group; proteinuria: 97.8 vs. 77.3 %, p < 0.001, hematuria: 97.8 vs. 75.0 %, p = 0.005, CR: 95.6 vs. 63.6 %, p < 0.001). In the Cox proportional hazard model (forced entry), SP protocol and proteinuria before treatment were significantly associated with CR [SP protocol: hazard ratio (HR) 2.50, 95 % confidence interval (CI) 1.46-4.30, p = 0.001, proteinuria: HR 0.81, 95 % CI 0.68-0.96, p = 0.013)]. However H-grade was associated with remission of proteinuria (H-grade: hazard ratio (HR) 0.56, 95 % confidence interval (CI) 0.37-0.85, p = 0.006), and this result meant histological bias affected the remission of proteinuria. The difference of the protocol of TSP therapy may have some effect on the CR of IgAN, though the histological bias was observed in this study. The appropriate protocol and indication of TSP therapy must be analyzed and determined in the randomized controlled trial.
Absolute quantitation of intracellular metabolite concentrations by an isotope ratio-based approach
Bennett, Bryson D; Yuan, Jie; Kimball, Elizabeth H; Rabinowitz, Joshua D
2009-01-01
This protocol provides a method for quantitating the intracellular concentrations of endogenous metabolites in cultured cells. The cells are grown in stable isotope-labeled media to near-complete isotopic enrichment and then extracted in organic solvent containing unlabeled internal standards in known concentrations. The ratio of endogenous metabolite to internal standard in the extract is determined using mass spectrometry (MS). The product of this ratio and the unlabeled standard amount equals the amount of endogenous metabolite present in the cells. The cellular concentration of the metabolite can then be calculated on the basis of intracellular volume of the extracted cells. The protocol is exemplified using Escherichia coli and primary human fibroblasts fed uniformly with 13C-labeled carbon sources, with detection of 13C-assimilation by liquid chromatography–tandem MS. It enables absolute quantitation of several dozen metabolites over ~1 week of work. PMID:18714298
Estimating the strength of bone using linear response
NASA Astrophysics Data System (ADS)
Gunaratne, Gemunu H.
2002-12-01
Accurate diagnostic tools are required for effective management of osteoporosis; one method to identify additional diagnostics is to search for observable consequences of bone loss. An analysis of a model system is used to show that weakening of a bone is accompanied by a reduction of the fraction of the bone that participates in load transmission. On the basis of this observation, it is argued that the ratio Γ of linear responses of a network to dc and high-frequency ac driving can be used as a surrogate for their strength. Protocols needed to obtain Γ for bone samples are discussed.
Axelrod, David M.; Chisti, Mohammod J.; Kache, Saraswati
2017-01-01
Background Pediatric sepsis has a high mortality rate in limited resource settings. Sepsis protocols have been shown to be a cost-effective strategy to improve morbidity and mortality in a variety of populations and settings. At Dhaka Hospital in Bangladesh, mortality from pediatric sepsis in high-risk children previously approached 60%, which prompted the implementation of an evidenced-based protocol in 2010. The clinical effectiveness of this protocol had not been measured. We hypothesized that implementation of a pediatric sepsis protocol improved clinical outcomes, including reducing mortality and length of hospital stay. Materials and methods This was a retrospective cohort study of children 1–59 months old with a diagnosis of sepsis, severe sepsis or septic shock admitted to Dhaka Hospital from 10/25/2009-10/25/2011. The primary outcome was inpatient mortality pre- and post-protocol implementation. Secondary outcomes included fluid overload, heart failure, respiratory insufficiency, length of hospital stay, and protocol compliance, as measured by antibiotic and fluid bolus administration within 60 minutes of hospital presentation. Results 404 patients were identified by a key-word search of the electronic medical record; 328 patients with a primary diagnosis of sepsis, severe sepsis, or septic shock were included (143 pre- and185 post-protocol) in the analysis. Pre- and post-protocol mortality were similar and not statistically significant (32.17% vs. 34.59%, p = 0.72). The adjusted odds ratio (AOR) for post-protocol mortality was 1.55 (95% CI, 0.88–2.71). The odds for developing fluid overload were significantly higher post-protocol (AOR 3.45, 95% CI, 2.04–5.85), as were the odds of developing heart failure (AOR 4.52, 95% CI, 1.43–14.29) and having a longer median length of stay (AOR 1.81, 95% CI 1.10–2.96). There was no statistically significant difference in respiratory insufficiency (pre- 65.7% vs. post- 70.3%, p = 0.4) or antibiotic administration between the cohorts (pre- 16.08% vs. post- 12.43%, p = 0.42). Conclusions Implementation of a pediatric sepsis protocol did not improve all-cause mortality or length of stay and may have been associated with increased fluid overload and heart failure during the study period in a large, non-governmental hospital in Bangladesh. Similar rates of early antibiotic administration may indicate poor protocol compliance. Though evidenced-based protocols are a potential cost-effective strategy to improve outcomes, future studies should focus on optimal implementation of context-relevant sepsis protocols in limited resource settings. PMID:28753618
Grenet, Guillaume; Lajoinie, Audrey; Ribault, Shams; Nguyen, Gia Bao; Linet, Thomas; Metge, Augustin; Cornu, Catherine; Cucherat, Michel; Moulin, Philippe; Gueyffier, François
2017-06-01
The aim of this study was to propose a ranking of the currently available antidiabetic drugs, regarding vascular clinical outcomes, in patients with type 2 diabetes, through a network meta-analysis approach. Randomized clinical trials, regardless of the blinding design, testing contemporary antidiabetic drugs, and considering clinically relevant outcomes in patients with type 2 diabetes mellitus will be included. The primary outcomes of this analysis will be overall mortality, cardiovascular mortality, and major cardiovascular events. Diabetic microangiopathy will be a secondary outcome. Adverse events, hypoglycemia, weight evolution, bariatric surgery, and discontinuation of the treatment will also be recorded. Each drug will be analyzed according to its therapeutic class: biguanide, alpha-glucosidase inhibitors, sulfonylureas, glitazones, glinides, insulin, DPP-4 inhibitors, GLP-1 analogs, and gliflozins. The treatment effect of each drug class will be compared using pairwise meta-analysis and a Bayesian random model network meta-analysis. Sensitivity analyses will be conducted according to the quality of the studies and the glycemic control. The report will follow the PRISMA checklist for network meta-analysis. Results of the search strategy and of the study selection will be presented in a PRISMA compliant flowchart. The treatment effects will be summarized with odds ratio (OR) estimates and their 95% credible intervals. A ranking of the drugs will be proposed. Our network meta-analysis should allow a clinically relevant ranking of the contemporary antidiabetic drugs. © 2016 Société Française de Pharmacologie et de Thérapeutique.
Greene, Stephen J; Hernandez, Adrian F; Sun, Jie-Lena; Metra, Marco; Butler, Javed; Ambrosy, Andrew P; Ezekowitz, Justin A; Starling, Randall C; Teerlink, John R; Schulte, Phillip J; Voors, Adriaan A; Armstrong, Paul W; O'Connor, Christopher M; Mentz, Robert J
2016-09-01
Most international acute heart failure trials have failed to show benefit with respect to key end points. The impact of site enrollment and protocol execution on trial performance is unclear. We assessed the impact of varying site enrollment volume among all 7141 acute heart failure patients from the ASCEND-HF trial (Acute Study of Clinical Effectiveness of Nesiritide in Decompensated Heart Failure). Overall, 398 sites enrolled ≥1 patient, and median enrollment was 12 patients (interquartile range, 5-23). Patients from high enrolling sites (>60 patients/site) tended to have lower ejection fraction, worse New York Heart Association functional class, and lower utilization of guideline-directed medical therapy but fewer comorbidities and lower B-type natriuretic peptide level. Every 10 patient increase (up to 100 patients) in site enrollment correlated with lower likelihood of protocol noncompletion (odds ratio, 0.93; 95% confidence interval [CI], 0.89-0.98). After adjustment, increasing site enrollment predicted higher risk of persistent dyspnea at 6 hours (per 10 patient increase: odds ratio 1.02; 95% CI, 1.01-1.03) but not at 24 hours (odds ratio, 0.99; 95% CI, 0.98-1.00). Higher site enrollment was independently associated with lower risk of 30-day death or rehospitalization (per 10 patient increase: odds ratio, 0.98, 95% CI, 0.96-0.99) but not 180-day mortality (hazard ratio, 0.99; 95% CI, 0.98-1.01). The influence of increasing site enrollment on clinical end points varied across geographic regions with strongest associations in Latin America and Asia-Pacific (all interaction P<0.01). In this large, acute heart failure trial, site enrollment correlated with protocol completion and was independently associated with trial end points. Individual and regional site performance present challenges to be considered in design of future acute heart failure trials. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00475852. © 2016 American Heart Association, Inc.
Bullich, Santiago; Barthel, Henryk; Koglin, Norman; Becker, Georg A; De Santi, Susan; Jovalekic, Aleksandar; Stephens, Andrew W; Sabri, Osama
2017-11-24
Accurate amyloid PET quantification is necessary for monitoring amyloid-beta accumulation and response to therapy. Currently, most of the studies are analyzed using the static standardized uptake value ratio (SUVR) approach because of its simplicity. However, this approach may be influenced by changes in cerebral blood flow (CBF) or radiotracer clearance. Full tracer kinetic models require arterial blood sampling and dynamic image acquisition. The objectives of this work were: (1) to validate a non-invasive kinetic modeling approach for 18 F-florbetaben PET using an acquisition protocol with the best compromise between quantification accuracy and simplicity and (2) to assess the impact of CBF changes and radiotracer clearance on SUVRs and non-invasive kinetic modeling data in 18 F-florbetaben PET. Methods: Data from twenty subjects (10 patients with probable Alzheimer's dementia/ 10 healthy volunteers) were used to compare the binding potential (BP ND ) obtained from the full kinetic analysis to the SUVR and to non-invasive tracer kinetic methods (simplified reference tissue model (SRTM), and multilinear reference tissue model 2 (MRTM2)). Different approaches using shortened or interrupted acquisitions were compared to the results of the full acquisition (0-140 min). Simulations were carried out to assess the effect of CBF and radiotracer clearance changes on SUVRs and non-invasive kinetic modeling outputs. Results: A 0-30 and 120-140 min dual time-window acquisition protocol using appropriate interpolation of the missing time points provided the best compromise between patient comfort and quantification accuracy. Excellent agreement was found between BP ND obtained using full and dual time-window (2TW) acquisition protocols (BP ND,2TW =0.01+ 1.00 BP ND,FULL , R2=0.97 (MRTM2); BP ND,2TW = 0.05+ 0.92·BP ND,FULL , R2=0.93 (SRTM)). Simulations showed a limited impact of CBF and radiotracer clearance changes on MRTM parameters and SUVRs. Conclusion: This study demonstrates accurate non-invasive kinetic modeling of 18 F-florbetaben PET data using a dual time-window acquisition protocol, thus providing a good compromise between quantification accuracy, scan duration and patient burden. The influence of CBF and radiotracer clearance changes on amyloid-beta load estimates was small. For most clinical research applications, the SUVR approach is appropriate. However, for longitudinal studies in which a maximum quantification accuracy is desired, this non-invasive dual time-window acquisition protocol and kinetic analysis is recommended. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Pharmacoeconomic comparison of Helicobacter pylori eradication regimens.
Sancar, Mesut; Izzettin, Fikret Vehbi; Apikoglu-Rabus, Sule; Besisik, Fatih; Tozun, Nurdan; Dulger, Gul
2006-08-01
Helicobacter pylori is the most important etiologic agent for development of peptic ulcer, chronic gastritis and gastric carcinomas. It is now well established that H. pylori eradication treatment is more cost-effective than acid suppressing therapies alone for the treatment of peptic ulcer disease. However, the comparative cost-effectiveness of various H. pylori eradication regimens is still not clear. This study was designed to make a pharmacoeconomic comparison of different H. pylori eradication regimens in patients with peptic ulcer disease or chronic gastritis, using real-world cost and effectiveness data. Istanbul University Hospital and Marmara University Hospital. A total of 75 patients diagnosed as H. pylori (+) by endoscopy were randomized to receive one of the seven H. pylori treatment protocols. These protocols were as follows: (LAC) = 'lansoprazole 30 mg bid + amoxicillin 1 g bid + clarithromycin 500 mg bid' for 7 days and (OCM) = 'omeprazole 20 mg bid + clarithromycin 250 mg bid + metronidazole 500 mg bid'; (OAM) = 'omeprazole 40 mg qd + amoxicillin 500 mg tid + metronidazole 500 mg tid'; (MARB) = 'metronidazole 250 mg tid + amoxicillin 500 mg qid + ranitidine 300 mg hs + bismuth 300 mg qid'; (OAC) = omeprazole 20 mg bid + amoxicillin 1 g bid + clarithromycin 500 mg bid'; (OCA) = omeprazole 40 mg bid + clarithromycin 500 mg bid + amoxicillin 1 g bid'; (OAB) = 'omeprazole 20 mg bid + amoxicillin 500 mg tid + bismuth 300 mg qid' each for 14 days. Only direct costs were included in the analysis. Effectiveness was measured in terms of "successful eradication". The cost-effectiveness ratios of the regimens were calculated using these effectiveness and cost data. The perspective of the study was assumed as the Government's perspective. Cost-effectiveness ratios of eradication regimens. MARB and OCA regimens were found to be more cost-effective than the other treatment regimens. The eradication rates and cost-effectiveness ratios calculated for these protocols were 90% (158.7 euros) for MARB and 90% (195.8 euros) for OCA regimen. This study confirms the importance of using local pharmacoeconomic data. Analyses such as this give decision-makers the tools to choose a better treatment option which is both highly effective yet and has a low cost.
Lipid Extraction Techniques for Stable Isotope Analysis and Ecological Assays.
Elliott, Kyle H; Roth, James D; Crook, Kevin
2017-01-01
Lipid extraction is an important component of many ecological and ecotoxicological measurements. For instance, percent lipid is often used as a measure of body condition, under the assumption that those individuals with higher lipid reserves are healthier. Likewise, lipids are depleted in 13 C compared with protein, and it is consequently a routine to remove lipids prior to measuring carbon isotopes in ecological studies so that variation in lipid content does not obscure variation in diet. We provide detailed methods for two different protocols for lipid extraction: Soxhlet apparatus and manual distillation. We also provide methods for polar and nonpolar solvents. Neutral (nonpolar) solvents remove some lipids but few non-lipid compounds, whereas polar solvents remove most lipids but also many non-lipid compounds. We discuss each of the methods and provide guidelines for best practices. We recommend that, for stable isotope analysis, researchers test for a relationship between the change in carbon stable isotope ratio and the amount of lipid extracted to see if the degree of extraction has an impact on isotope ratios. Stable isotope analysis is widely used by ecologists, and we provide a detailed methodology that minimizes known biases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inoue, Masaharu; Koga, Fumitaka, E-mail: f-koga@cick.jp; Yoshida, Soichiro
2014-10-01
Purpose: To investigate the associations of ERBB 2 overexpression with chemoradiation therapy (CRT) resistance and cancer-specific survival (CSS) in muscle-invasive bladder cancer (MIBC) patients treated with the CRT-based bladder-sparing protocol. Methods and Materials: From 1997 to 2012, 201 patients with cT2-4aN0M0 bladder cancer were treated with CRT (40 Gy with concurrent cisplatin) following transurethral resection of bladder tumor (TURBT). Basically, patients with tumors that showed good CRT response and were amenable to segmental resection underwent partial cystectomy (PC) with pelvic lymph node dissection for bladder preservation; otherwise, radical cystectomy (RC) was recommended. Included in this study were 119 patients in whom TURBTmore » specimens were available for immunohistochemical analysis of ERBB 2 expression. Following CRT, 30 and 65 patients underwent PC or RC, respectively; the remaining 24 patients did not undergo cystectomy. Tumors were defined as CRT-resistant when patients did not achieve complete response after CRT. Associations of ERBB 2 overexpression with CRT resistance and CSS were evaluated. Results: CRT resistance was observed clinically in 56% (67 of 119 patients) and pathologically (in cystectomy specimens) in 55% (52 of 95 patients). ERBB 2 overexpression was observed in 45 patients (38%). On multivariate analysis, ERBB 2 overexpression was an independent predictor for CRT resistance clinically (odds ratio, 3.6; P=.002) and pathologically (odds ratio, 2.9; P=.031). ERBB 2 overexpression was associated with shorter CSS (5-year CSS rates, 56% vs 87% for the ERBB 2 overexpression group vs the others; P=.001). ERBB 2 overexpression was also an independent risk factor for bladder cancer death at all time points of our bladder-sparing protocol (pre-CRT, post-CRT, and post-cystectomy). Conclusions: ERBB 2 overexpression appears relevant to CRT resistance and unfavorable CSS in MIBC patients treated with the CRT-based bladder-sparing protocol. ERBB 2-targeting treatment may improve the outcomes of such patients.« less
Inoue, Masaharu; Koga, Fumitaka; Yoshida, Soichiro; Tamura, Tomoki; Fujii, Yasuhisa; Ito, Eisaku; Kihara, Kazunori
2014-10-01
To investigate the associations of ERBB 2 overexpression with chemoradiation therapy (CRT) resistance and cancer-specific survival (CSS) in muscle-invasive bladder cancer (MIBC) patients treated with the CRT-based bladder-sparing protocol. From 1997 to 2012, 201 patients with cT2-4aN0M0 bladder cancer were treated with CRT (40 Gy with concurrent cisplatin) following transurethral resection of bladder tumor (TURBT). Basically, patients with tumors that showed good CRT response and were amenable to segmental resection underwent partial cystectomy (PC) with pelvic lymph node dissection for bladder preservation; otherwise, radical cystectomy (RC) was recommended. Included in this study were 119 patients in whom TURBT specimens were available for immunohistochemical analysis of ERBB 2 expression. Following CRT, 30 and 65 patients underwent PC or RC, respectively; the remaining 24 patients did not undergo cystectomy. Tumors were defined as CRT-resistant when patients did not achieve complete response after CRT. Associations of ERBB 2 overexpression with CRT resistance and CSS were evaluated. CRT resistance was observed clinically in 56% (67 of 119 patients) and pathologically (in cystectomy specimens) in 55% (52 of 95 patients). ERBB 2 overexpression was observed in 45 patients (38%). On multivariate analysis, ERBB 2 overexpression was an independent predictor for CRT resistance clinically (odds ratio, 3.6; P=.002) and pathologically (odds ratio, 2.9; P=.031). ERBB 2 overexpression was associated with shorter CSS (5-year CSS rates, 56% vs 87% for the ERBB 2 overexpression group vs the others; P=.001). ERBB 2 overexpression was also an independent risk factor for bladder cancer death at all time points of our bladder-sparing protocol (pre-CRT, post-CRT, and post-cystectomy). ERBB 2 overexpression appears relevant to CRT resistance and unfavorable CSS in MIBC patients treated with the CRT-based bladder-sparing protocol. ERBB 2-targeting treatment may improve the outcomes of such patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Hanousek, Ondrej; Berger, Torsten W; Prohaska, Thomas
2016-01-01
Analysis of (34)S/(32)S of sulfate in rainwater and soil solutions can be seen as a powerful tool for the study of the sulfur cycle. Therefore, it is considered as a useful means, e.g., for amelioration and calibration of ecological or biogeochemical models. Due to several analytical limitations, mainly caused by low sulfate concentration in rainwater, complex matrix of soil solutions, limited sample volume, and high number of samples in ecosystem studies, a straightforward analytical protocol is required to provide accurate S isotopic data on a large set of diverse samples. Therefore, sulfate separation by anion exchange membrane was combined with precise isotopic measurement by multicollector inductively coupled plasma mass spectrometry (MC ICP-MS). The separation method proved to be able to remove quantitatively sulfate from matrix cations (Ca, K, Na, or Li) which is a precondition in order to avoid a matrix-induced analytical bias in the mass spectrometer. Moreover, sulfate exchange on the resin is capable of preconcentrating sulfate from low concentrated solutions (to factor 3 in our protocol). No significant sulfur isotope fractionation was observed during separation and preconcentration. MC ICP-MS operated at edge mass resolution has enabled the direct (34)S/(32)S analysis of sulfate eluted from the membrane, with an expanded uncertainty U (k = 2) down to 0.3 ‰ (a single measurement). The protocol was optimized and validated using different sulfate solutions and different matrix compositions. The optimized method was applied in a study on solute samples retrieved in a beech (Fagus sylvatica) forest in the Vienna Woods. Both rainwater (precipitation and tree throughfall) and soil solution δ (34)SVCDT ranged between 4 and 6 ‰, the ratio in soil solution being slightly lower. The lower ratio indicates that a considerable portion of the atmospherically deposited sulfate is cycled through the organic S pool before being released to the soil solution. Nearly the same trends and variations were observed in soil solution and rainwater δ (34)SVCDT values showing that sulfate adsorption/desorption are not important processes in the studied soil.
NASA Astrophysics Data System (ADS)
Li, S.; Park, S.; Park, M.; Kim, J.; Muhle, J.; Fang, X.; Stohl, A.; Weiss, R. F.; Kim, K.
2013-12-01
In this study we estimate the emission rates of anthropogenic halocarbons, which include CFC-11, CFC-12, HCFC-22, HCFC-141b, HCFC-142b, HFC-23, HFC-134a, HFC-32, HFC-125 and HFC-152a for China during the period of 2008 and 2012 using an interspecies correlation method (Kim et al., 2010; Li et al., 2011), which is a unique 'top-down' approach using in situ high-precision measurements at Gosan, a remote station on Jeju Island, Korea. Mixing ratios of ambient halocarbons have been measured every two hours using a cryogenic pre-concentration system coupled with gas chromatograph and mass selective detector (GC-MSD) as part of the Advanced Global Atmospheric Gases Experiment network. We first separated air-mass segments originating from China using a back-trajectory analysis to identify Chinese emission from the observations, and found that the mixing ratios of most of compounds presented significant correlations against those of HCFC-22. Based on the correlations, we analyzed emission strengths of individual compounds, which correspond to their slopes against HCFC-22 since the slope can be a useful proxy to demonstrate their emission trends with an assumption of relatively constant emission of HCFC-22 during the analysis period. The analysis showed about 14% increase in the emissions strengths of CFCs (mainly due to CFC-12) between 2008 and 2012 in China. Interestingly, HCFC-141b and HCFC-142b that are commonly known to be used for foam blowing agents revealed opposite trends in their emission strengths: ca. 48% increase of HCFC-141b versus ca. 22% decrease of HCFC-142b, suggesting the possibility of other major sources in case of China. The emission strengths of HFCs have been increasing due to significant emissions of HFC-32, HFC-125 and HFC-134a during the analysis period. However, HFC-23 which is a well-known byproduct of HCFC-22 production processes, showed decrease by about 22% in the emission strength. Reduction in HFC-23 emissions is most likely due to the nationwide effort for the Clean Development Mechanism project benefit of the Kyoto protocol. Emission rates of the halocarbons determined from the empirical emission strengths will certainly vary according to emission trend of our reference species, HCFC-22 in China from 2008 and 2012. Annual and average of HCFC-22 emissions from 2008 to 2012 will be calculated with an inverse method based on FLEXPART transport model. More detailed discussion on the emission rate estimation and its related caveats will be made in the presentation, but overall our analysis highlights the significance of long-term continuous monitoring for CFCs, HCFCs and HFCs in China to investigate impacts of Montreal Protocol regulations.
Liu, Wei; Yin, Huiyong; Akazawa, Yoko Ogawa; Yoshida, Yasukazu; Niki, Etsuo; Porter, Ned A.
2010-01-01
The primary products from peroxidation of linoleate in biological tissues and fluids are the hydroperoxy octadecadienoates and the products normally assayed, after reduction of the hydroperoxides, are the corresponding hydroxy octadecadienoates (HODEs). The HODEs are found in tissues and fluids as a mixture of Z,E and E,E stereoisomers. Two regioisomeric sets of Z,E and E,E stereoisomers are normally observed with substitution at the 9 and 13 position of the 18-carbon chain. The Z,E/E,E product ratio has proved to be a useful means for assessing the reducing capacity of the medium undergoing peroxidation. The HODE Z,E/E,E product ratios previously reported for tissues such as liver and brain vary from 0.5 to 2.0 and plasma ratios are somewhat higher, between 2.0 and 3.0. The reported literature protocols for HODE assay in tissues involve homogenization, reduction with sodium borohydride in the presence of BHT, and ester hydrolysis with KOH to give the free HODEs. This is followed by either reverse-phase HPLC of the free acid HODEs or by conversion to TMS derivatives and GC/MS. When sodium borohydride is replaced in the protocol by triphenylphosphine, a gentler reducing agent, HODE Z,E/E,E product ratios are much higher and lower total HODEs levels of are found. It is proposed that inclusion of sodium borohydride in the isolation procedures leads to ex vivo reactions that are avoided if triphenylphosphine is used as the reducing agent. Modified protocols for HODE analyses (Tissue and Plasma Methods #2) are described that should be used for assays of tissues and fluids. PMID:20423158
A Tree Based Broadcast Scheme for (m, k)-firm Real-Time Stream in Wireless Sensor Networks.
Park, HoSung; Kim, Beom-Su; Kim, Kyong Hoon; Shah, Babar; Kim, Ki-Il
2017-11-09
Recently, various unicast routing protocols have been proposed to deliver measured data from the sensor node to the sink node within the predetermined deadline in wireless sensor networks. In parallel with their approaches, some applications demand the specific service, which is based on broadcast to all nodes within the deadline, the feasible real-time traffic model and improvements in energy efficiency. However, current protocols based on either flooding or one-to-one unicast cannot meet the above requirements entirely. Moreover, as far as the authors know, there is no study for the real-time broadcast protocol to support the application-specific traffic model in WSN yet. Based on the above analysis, in this paper, we propose a new ( m , k )-firm-based Real-time Broadcast Protocol (FRBP) by constructing a broadcast tree to satisfy the ( m , k )-firm, which is applicable to the real-time model in resource-constrained WSNs. The broadcast tree in FRBP is constructed by the distance-based priority scheme, whereas energy efficiency is improved by selecting as few as nodes on a tree possible. To overcome the unstable network environment, the recovery scheme invokes rapid partial tree reconstruction in order to designate another node as the parent on a tree according to the measured ( m , k )-firm real-time condition and local states monitoring. Finally, simulation results are given to demonstrate the superiority of FRBP compared to the existing schemes in terms of average deadline missing ratio, average throughput and energy consumption.
2014-01-01
Controlling harmful algae blooms (HABs) using microbial algicides is cheap, efficient and environmental-friendly. However, obtaining high yield of algicidal microbes to meet the need of field test is still a big challenge since qualitative and quantitative analysis of algicidal compounds is difficult. In this study, we developed a protocol to increase the yield of both biomass and algicidal compound present in a novel algicidal actinomycete Streptomyces alboflavus RPS, which kills Phaeocystis globosa. To overcome the problem in algicidal compound quantification, we chose algicidal ratio as the index and used artificial neural network to fit the data, which was appropriate for this nonlinear situation. In this protocol, we firstly determined five main influencing factors through single factor experiments and generated the multifactorial experimental groups with a U15(155) uniform-design-table. Then, we used the traditional quadratic polynomial stepwise regression model and an accurate, fully optimized BP-neural network to simulate the fermentation. Optimized with genetic algorithm and verified using experiments, we successfully increased the algicidal ratio of the fermentation broth by 16.90% and the dry mycelial weight by 69.27%. These results suggested that this newly developed approach is a viable and easy way to optimize the fermentation conditions for algicidal microorganisms. PMID:24886410
Cai, Guanjing; Zheng, Wei; Yang, Xujun; Zhang, Bangzhou; Zheng, Tianling
2014-05-24
Controlling harmful algae blooms (HABs) using microbial algicides is cheap, efficient and environmental-friendly. However, obtaining high yield of algicidal microbes to meet the need of field test is still a big challenge since qualitative and quantitative analysis of algicidal compounds is difficult. In this study, we developed a protocol to increase the yield of both biomass and algicidal compound present in a novel algicidal actinomycete Streptomyces alboflavus RPS, which kills Phaeocystis globosa. To overcome the problem in algicidal compound quantification, we chose algicidal ratio as the index and used artificial neural network to fit the data, which was appropriate for this nonlinear situation. In this protocol, we firstly determined five main influencing factors through single factor experiments and generated the multifactorial experimental groups with a U15(155) uniform-design-table. Then, we used the traditional quadratic polynomial stepwise regression model and an accurate, fully optimized BP-neural network to simulate the fermentation. Optimized with genetic algorithm and verified using experiments, we successfully increased the algicidal ratio of the fermentation broth by 16.90% and the dry mycelial weight by 69.27%. These results suggested that this newly developed approach is a viable and easy way to optimize the fermentation conditions for algicidal microorganisms.
Melilli, Edoardo; Crespo, Elena; Sandoval, Diego; Manonelles, Anna; Sala, Neus; Mast, Richard; Padulles, Ariadna; Grinyo, Josep M; Bestard, Oriol; Cruzado, Josep Maria
2015-11-01
The use of generic formulations of immunosuppressive drugs in renal transplantation has been and still is a controversial subject. The lack of clinical studies about safety and efficacy in transplant patients is one of the factors restricting the diffusion of generic drugs in the renal transplant field. Since March 2013, our transplant unit has incorporated generic tacrolimus (Adoport(®) ; Sandoz), replacing the one we were currently using (Prograf(®) ; Astellas). When carrying out our retrospective analysis comparing the two different formulations, we evaluated several clinical results: tacrolimus trough concentrations (C0) at 5-7 days; 1, 3, and 6 months post-transplantation; concentration/dose ratio at 6 months; acute rejection incidence; delayed graft function (DGF); renal function (as CKD-EPI); and proteinuria at 6 months in 120 patients (1:1 ratio of Prograf(®) versus Adoport(®) ), noticing no important differences. We also evaluated the results of protocol biopsies at 6 months in a subgroup of patients, thus verifying the safety and efficacy of this particular generic drug versus the reference product on a histological basis as well. No difference in the development of dnDSA (de novo donor-specific antibody) was found between the two groups. © 2015 Steunstichting ESOT.
Constructing and assessing brain templates from Chinese pediatric MRI data using SPM
NASA Astrophysics Data System (ADS)
Yin, Qingjie; Ye, Qing; Yao, Li; Chen, Kewei; Jin, Zhen; Liu, Gang; Wu, Xingchun; Wang, Tingting
2005-04-01
Spatial normalization is a very important step in the processing of magnetic resonance imaging (MRI) data. So the quality of brain templates is crucial for the accuracy of MRI analysis. In this paper, using the classical protocol and the optimized protocol plus nonlinear deformation, we constructed the T1 whole brain templates and apriori brain tissue data from 69 Chinese pediatric MRI data (age 7-16 years). Then we proposed a new assessment method to evaluate our templates. 10 pediatric subjects were chosen to do the assessment as the following steps. First, the cerebellum region, the region of interest (ROI), was located on both the pediatric volume and the template volume by an experienced neuroanatomist. Second, the pediatric whole brain was mapped to the template with affine and nonlinear deformation. Third, the parameter, derived from the second step, was used to only normalize the ROI of the child to the ROI of the template. Last, the overlapping ratio, which described the overlapping rate between the ROI of the template and the normalized ROI of the child, was calculated. The mean of overlapping ratio normalized to the classical template was 0.9687, and the mean normalized to the optimized template was 0.9713. The results show that the two Chinese pediatric brain templates are comparable and their accuracy is adequate to our studies.
Sibille, Louis; Chambert, Benjamin; Alonso, Sandrine; Barrau, Corinne; D'Estanque, Emmanuel; Al Tabaa, Yassine; Collombier, Laurent; Demattei, Christophe; Kotzki, Pierre-Olivier; Boudousq, Vincent
2016-07-01
The purpose of this study was to compare a routine bone SPECT/CT protocol using CT reconstructed with filtered backprojection (FBP) with an optimized protocol using low-dose CT images reconstructed with adaptive statistical iterative reconstruction (ASiR). In this prospective study, enrolled patients underwent bone SPECT/CT, with 1 SPECT acquisition followed by 2 randomized CT acquisitions: FBP CT (FBP; noise index, 25) and ASiR CT (70% ASiR; noise index, 40). The image quality of both attenuation-corrected SPECT and CT images was visually (5-point Likert scale, 2 interpreters) and quantitatively (contrast ratio [CR] and signal-to-noise ratio [SNR]) estimated. The CT dose index volume, dose-length product, and effective dose were compared. Seventy-five patients were enrolled in the study. Quantitative attenuation-corrected SPECT evaluation showed no inferiority for contrast ratio and SNR issued from FBP CT or ASiR CT (respectively, 13.41 ± 7.83 vs. 13.45 ± 7.99 and 2.33 ± 0.83 vs. 2.32 ± 0.84). Qualitative image analysis showed no difference between attenuation-corrected SPECT images issued from FBP CT or ASiR CT for both interpreters (respectively, 3.5 ± 0.6 vs. 3.5 ± 0.6 and 3.6 ± 0.5 vs. 3.6 ± 0.5). Quantitative CT evaluation showed no inferiority for SNR between FBP and ASiR CT images (respectively, 0.93 ± 0.16 and 1.07 ± 0.17). Qualitative image analysis showed no quality difference between FBP and ASiR CT images for both interpreters (respectively, 3.8 ± 0.5 vs. 3.6 ± 0.5 and 4.0 ± 0.1 vs. 4.0 ± 0.2). Mean CT dose index volume, dose-length product, and effective dose for ASiR CT (3.0 ± 2.0 mGy, 148 ± 85 mGy⋅cm, and 2.2 ± 1.3 mSv) were significantly lower than for FBP CT (8.5 ± 3.7 mGy, 365 ± 160 mGy⋅cm, and 5.5 ± 2.4 mSv). The use of 70% ASiR blending in bone SPECT/CT can reduce the CT radiation dose by 60%, with no sacrifice in attenuation-corrected SPECT and CT image quality, compared with the conventional protocol using FBP CT reconstruction technique. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Evaluation of N-ratio in selecting patients for adjuvant chemoradiotherapy after d2-gastrectomy.
Costa Junior, Wilson Luiz da; Coimbra, Felipe José Fernández; Batista, Thales Paulo; Ribeiro, Héber Salvador de Castro; Diniz, Alessandro Landskron
2013-01-01
Whether adjuvant chemoradiotherapy may contribute to improve survival outcomes after D2-gastrectomy remains controversial. To explore the clinical utility of N-Ratio in selecting gastric cancer patients for adjuvant chemoradiotherapy after D2-gastrectomy. A retrospective cohort study was carried out on gastric cancer patients who underwent D2-gastrectomy alone or D2-gastrectomy plus adjuvant chemoradiotherapy (INT-0116 protocol) at the Hospital A. C. Camargo from September 1998 to December 2008. Statistical analysis were performed using multiple conventional methods, such as c-statistic, adjusted Cox's regression and stratified survival analysis. Our analysis involved 128 patients. According to c-statistic, the N-Ratio (i.e., as a continuous variable) presented "area under ROC curve" (AUC) of 0.713, while the number of metastatic nodes presented AUC of 0.705. After categorization, the cut-offs provide by Marchet et al. displayed the highest discriminating power - AUC value of 0.702. This N-Ratio categorization was confirmed as an independent predictor of survival using multivariate analyses. There also was a trend of better survival by adding of adjuvant chemoradiotherapy only for patients with milder degrees of lymphatic spread - 5-year survival of 23.1% vs 66.9%, respectively (HR = 0.426, 95% CI 0.150-1.202; P = 0.092). This study confirms the N-Ratio as a tool to improve the lymph node metastasis staging in gastric cancer and suggests the cut-offs provided by Marchet et al. as the best way for its categorization after a D2-gastrectomy. In these settings, the N-Ratio appears a useful tool to select patients for adjuvant chemoradiotherapy, and the benefit of adding this type of adjuvancy to D2-gastrectomy is suggested to be limited to patients with milder degrees of lymphatic spread (i.e., NR2, 10%-25%).
Saieg, Mauro Ajaj; Geddie, William R; Boerner, Scott L; Liu, Ni; Tsao, Ming; Zhang, Tong; Kamel-Reid, Suzanne; da Cunha Santos, Gilda
2012-06-25
Novel high-throughput molecular technologies have made the collection and storage of cells and small tissue specimens a critical issue. The FTA card provides an alternative to cryopreservation for biobanking fresh unfixed cells. The current study compared the quality and integrity of the DNA obtained from 2 types of FTA cards (Classic and Elute) using 2 different extraction protocols ("Classic" and "Elute") and assessed the feasibility of performing multiplex mutational screening using fine-needle aspiration (FNA) biopsy samples. Residual material from 42 FNA biopsies was collected in the cards (21 Classic and 21 Elute cards). DNA was extracted using the Classic protocol for Classic cards and both protocols for Elute cards. Polymerase chain reaction for p53 (1.5 kilobase) and CARD11 (500 base pair) was performed to assess DNA integrity. Successful p53 amplification was achieved in 95.2% of the samples from the Classic cards and in 80.9% of the samples from the Elute cards using the Classic protocol and 28.5% using the Elute protocol (P = .001). All samples (both cards) could be amplified for CARD11. There was no significant difference in the DNA concentration or 260/280 purity ratio when the 2 types of cards were compared. Five samples were also successfully analyzed by multiplex MassARRAY spectrometry, with a mutation in KRAS found in 1 case. High molecular weight DNA was extracted from the cards in sufficient amounts and quality to perform high-throughput multiplex mutation assays. The results of the current study also suggest that FTA Classic cards preserve better DNA integrity for molecular applications compared with the FTA Elute cards. Copyright © 2012 American Cancer Society.
Fu, Xi; Qiao, Jia; Girod, Sabine; Niu, Feng; Liu, Jian Feng; Lee, Gordon K; Gui, Lai
2017-09-01
Mandible contour surgery, including reduction gonioplasty and genioplasty, has become increasingly popular in East Asia. However, it is technically challenging and, hence, leads to a long learning curve and high complication rates and often needs secondary revisions. The increasing use of 3-dimensional (3D) technology makes accurate single-stage mandible contour surgery with minimum complication rates possible with a virtual surgical plan (VSP) and 3-D surgical templates. This study is to establish a standardized protocol for VSP and 3-D surgical templates-assisted mandible contour surgery and evaluate the accuracy of the protocol. In this study, we enrolled 20 patients for mandible contour surgery. Our protocol is to perform VSP based on 3-D computed tomography data. Then, design and 3-D print surgical templates based on preoperative VSP. The accuracy of the method was analyzed by 3-D comparison of VSP and postoperative results using detailed computer analysis. All patients had symmetric, natural osteotomy lines and satisfactory facial ratios in a single-stage operation. The average relative error of VSP and postoperative result on the entire skull was 0.41 ± 0.13 mm. The average new left gonial error was 0.43 ± 0.77 mm. The average new right gonial error was 0.45 ± 0.69 mm. The average pognion error was 0.79 ± 1.21 mm. Patients were very satisfied with the aesthetic results. Surgeons were very satisfied with the performance of surgical templates to facilitate the operation. Our standardized protocol of VSP and 3-D printed surgical templates-assisted single-stage mandible contour surgery results in accurate, safe, and predictable outcome in a single stage.
Kuppens, S M I; Hasaart, T H M; van der Donk, M W P; Huibers, M; Franssen, M J; de Becker, B M J; Wijnen, H A A; Pop, V J M
2008-06-07
Identification of determinants affecting the outcome of external cephalic version (ECV) in breech presentation, and investigation of the impact of ECV--performed according to a standardized protocol in an outpatient clinic--on the mode of delivery. Retrospective analysis. In 2003 a standardized protocol of ECV was developed in the outpatient clinic for obstetrics of the Catharina Hospital in Eindhoven, the Netherlands; it was tested in 'version office visits'. Obstetric characteristics of all pregnant women who underwent attempts of ECV in the clinic from January 2004 until June 2006 during these sessions, and the subsequent births, were analysed. 85% of all ECVs were performed by the same hospital midwife and gynaecologist, in accordance with the protocol. ECV was successful in 96 of 209 pregnant women (46%). In 1 pregnant woman an emergency caesarean section was performed after ECV because of partial abruptio placentae. Nulliparity, incomplete breech presentation and low birth weight of the baby were associated with a lower success rate of ECV in this study. In the group with a successful ECV the percentage of caesarean deliveries was substantially lower (9 versus 83%; odds ratio: 0.21; 95% CI: 0.09-0.51). A regular team consisting of a hospital midwife and a gynaecologist working according to a standardized protocol for ECV in a case of breech presentation proved successful: the number of term breech presentations substantially diminished and therefore the percentage of caesarean sections was lower in the group in which ECV had been successful. This could have considerable impact on health care in the Netherlands in terms of reduced maternal morbidity and cost savings.
Analyzing the effect of routing protocols on media access control protocols in radio networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrett, C. L.; Drozda, M.; Marathe, A.
2002-01-01
We study the effect of routing protocols on the performance of media access control (MAC) protocols in wireless radio networks. Three well known MAC protocols: 802.11, CSMA, and MACA are considered. Similarly three recently proposed routing protocols: AODV, DSR and LAR scheme 1 are considered. The experimental analysis was carried out using GloMoSim: a tool for simulating wireless networks. The main focus of our experiments was to study how the routing protocols affect the performance of the MAC protocols when the underlying network and traffic parameters are varied. The performance of the protocols was measured w.r.t. five important parameters: (i)more » number of received packets, (ii) average latency of each packet, (iii) throughput (iv) long term fairness and (v) number of control packets at the MAC layer level. Our results show that combinations of routing and MAC protocols yield varying performance under varying network topology and traffic situations. The result has an important implication; no combination of routing protocol and MAC protocol is the best over all situations. Also, the performance analysis of protocols at a given level in the protocol stack needs to be studied not locally in isolation but as a part of the complete protocol stack. A novel aspect of our work is the use of statistical technique, ANOVA (Analysis of Variance) to characterize the effect of routing protocols on MAC protocols. This technique is of independent interest and can be utilized in several other simulation and empirical studies.« less
40 CFR 1048.110 - How must my engines diagnose malfunctions?
Code of Federal Regulations, 2013 CFR
2013-07-01
... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...
40 CFR 1048.110 - How must my engines diagnose malfunctions?
Code of Federal Regulations, 2012 CFR
2012-07-01
... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...
40 CFR 1048.110 - How must my engines diagnose malfunctions?
Code of Federal Regulations, 2014 CFR
2014-07-01
... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...
Widmann, G; Juranek, D; Waldenberger, F; Schullian, P; Dennhardt, A; Hoermann, R; Steurer, M; Gassner, E-M; Puelacher, W
2017-08-01
Dose reduction on CT scans for surgical planning and postoperative evaluation of midface and orbital fractures is an important concern. The purpose of this study was to evaluate the variability of various low-dose and iterative reconstruction techniques on the visualization of orbital soft tissues. Contrast-to-noise ratios of the optic nerve and inferior rectus muscle and subjective scores of a human cadaver were calculated from CT with a reference dose protocol (CT dose index volume = 36.69 mGy) and a subsequent series of low-dose protocols (LDPs I-4: CT dose index volume = 4.18, 2.64, 0.99, and 0.53 mGy) with filtered back-projection (FBP) and adaptive statistical iterative reconstruction (ASIR)-50, ASIR-100, and model-based iterative reconstruction. The Dunn Multiple Comparison Test was used to compare each combination of protocols (α = .05). Compared with the reference dose protocol with FBP, the following statistically significant differences in contrast-to-noise ratios were shown (all, P ≤ .012) for the following: 1) optic nerve: LDP-I with FBP; LDP-II with FBP and ASIR-50; LDP-III with FBP, ASIR-50, and ASIR-100; and LDP-IV with FBP, ASIR-50, and ASIR-100; and 2) inferior rectus muscle: LDP-II with FBP, LDP-III with FBP and ASIR-50, and LDP-IV with FBP, ASIR-50, and ASIR-100. Model-based iterative reconstruction showed the best contrast-to-noise ratio in all images and provided similar subjective scores for LDP-II. ASIR-50 had no remarkable effect, and ASIR-100, a small effect on subjective scores. Compared with a reference dose protocol with FBP, model-based iterative reconstruction may show similar diagnostic visibility of orbital soft tissues at a CT dose index volume of 2.64 mGy. Low-dose technology and iterative reconstruction technology may redefine current reference dose levels in maxillofacial CT. © 2017 by American Journal of Neuroradiology.
Birth weight and optic nerve head parameters.
Samarawickrama, Chameen; Huynh, Son C; Liew, Gerald; Burlutsky, George; Mitchell, Paul
2009-06-01
To assess the relationship of birth weight, birth length, and head circumference as proxy markers of intrauterine growth, cup/disc ratio, and other optic disc parameters measured using optical coherence tomography (OCT). Population-based cross sectional analysis. The Sydney Childhood Eye Study examined 2353 primarily 12-year-old children from 21 randomly selected secondary schools during 2003 to 2005. Of 2353 children examined, 2134 (90.7%) had OCT scans (Zeiss Stratus OCT, Carl Zeiss Meditec, Dublin, CA) and are included in this study. The "fast" optic disc scan protocol was used. Birth weight, birth length, and head circumference were ascertained from health records. Height and weight were measured using standardized protocols, body mass index (BMI) was defined as weight (kilograms)/ height squared (meters), and sociodemographic information was collected in a questionnaire completed by parents. Low birth weight was defined as birth weight
DOT National Transportation Integrated Search
2006-08-01
The purpose of this Traffic Noise Analysis Protocol for New Highway : Construction, Reconstruction, and Retrofit Barrier Projects (Protocol) is : to present California Department of Transportation (Caltrans) policies and : procedures for applying 23 ...
Okayama, Tetsuya; Ishikawa, Takeshi; Sugatani, Kazuko; Yoshida, Naohisa; Kokura, Satoshi; Matsuda, Kiyomi; Tsukamoto, Shigeru; Ihara, Norihiko; Kuriu, Yoshiaki; Nakanishi, Masayoshi; Nakamura, Terukazu; Kamada, Kazuhiro; Katada, Kazuhiro; Uchiyama, Kazuhiko; Takagi, Tomohisa; Handa, Osamu; Konishi, Hideyuki; Yagi, Nobuaki; Naito, Yuji; Otsuji, Eigo; Hosoi, Hajime; Miki, Tsuneharu; Itoh, Yoshito
2015-06-01
We examined the clinical data of patients treated with oxaliplatin to determine the risk factors of oxaliplatin-related hypersensitivity reaction (HSR). In addition, we evaluated the efficacy of rechallenging patients with HSRs with oxaliplatin using prophylactic agents or desensitization procedures. This study consisted of 162 patients with colorectal cancer (88 men and 74 women) who were treated consecutively at the outpatient chemotherapy department at University Hospital, Kyoto Prefectural University of Medicine. Patients underwent chemotherapy, including oxaliplatin, between March 2006 and June 2012. We analyzed the patients' clinical backgrounds (eg, age, sex, performance status, disease stage, and allergic history) to uncover any connections to the development of HSR to oxaliplatin. In addition, we rechallenged 10 patients who had oxaliplatin-related HSR using prophylactic agents or desensitization procedures. Of 162 patients, 28 (17.2%) developed oxaliplatin-related HSRs (16, 2, 9 and 1 patient had grade 1, 2, 3, and 4 HSRs, respectively). The total cumulative dose of oxaliplatin at the onset of the HSR was 301 to 1126 mg/m(2) (median, 582 mg/m(2)), and the first reactions developed in these patients after 5 to 17 infusions of oxaliplatin (median, 8 infusions). Logistic regression analysis indicated that sex (male: odds ratio = 3.624; 95% CI, 1.181-11.122; P = 0.024) and eosinophil count in peripheral blood (odds ratio = 35.118; 95% CI, 1.058-1166.007; P = 0.046) were independent variables for oxaliplatin-related HSRs. Rechallenging patients with prophylactic agents was successful in 2 (28.6%) of 7 patients who successfully completed their treatment. On the other hand, all 3 patients rechallenged with oxaliplatin using a desensitization protocol successfully completed their treatment without new HSRs. In this retrospective study, we observed that being male and having higher counts of peripheral eosinophil could be predictors for HSR to oxaliplatin. In addition, this study confirms that oxaliplatin desensitization protocol allows patients who developed HSRs to continue with their treatment. However, the optimum desensitization protocol for oxaliplatin administration in terms of tolerability and efficacy needs to be defined. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.
Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction.
Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko
2015-02-01
Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student's T test was used. There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction.
Evaluating the features of the brain waves to quantify ADHD improvement by neurofeedback.
Dehghanpour, Peyman; Einalou, Zahra
2017-10-23
Attention-deficit/hyperactivity disorder (ADHD), as one of the most common neurological disorders in children and adolescents, is characterized by decentralization, slow learning, distraction and hyperactivity. Studies have shown that in addition to medication, neurofeedback training can also be used to partially control the brain activity of these patients. In this study, using the brain signals processing before and after the treatment in 10 children treated by neurofeedback, the changes were evaluated by non-parametric statistical analysis and impact of neurofeedback on brain frequency bands was investigated. Finally, the results were compared with the protocols introduced in this paper and before researches. The results of Kruskal-Wallis test showed an approximately significant increase in the relative power of gamma and an approximately significant reduction in the ratio of relative power of alpha/beta. It represents the emotional response, elicited by the successful learning and diminished ratio of slow learning to active learning respectively.
Erez, Aharon; Kivity, Shaye; Berkovitch, Anat; Milwidsky, Assi; Klempfner, Robert; Segev, Shlomo; Goldenberg, Ilan; Sidi, Yechezkel; Maor, Elad
2015-06-01
We aimed to evaluate whether reduced cardiovascular fitness has a direct or indirect effect for the development of cardiovascular disease. We investigated 15,595 men and women who were annually screened in a tertiary medical center. All subjects were free of ischemic heart disease and had completed maximal exercise stress test according to the Bruce protocol at their first visit. Fitness was categorized into age- and sex-specific quintiles (Q) according to Bruce protocol treadmill time with Q1 as lowest fitness. Subjects were categorized at baseline into 3 groups: low fitness (Q1), moderate fitness (Q2-Q4), and high fitness (Q5). The primary end point of the current analysis was the development of a first cardiovascular event during follow-up. Mean age of study patients was 48 ± 10 years, and 73% were men. A total of 679 events occurred during 92,092 person-years of follow-up. Kaplan-Meier survival analysis showed that the cumulative probability of cardiovascular events at 6 years was significantly higher among subjects with low fitness (P < .001). Low fitness was associated with known cardiovascular risk factors, including hypercholesterolemia (odds ratio [OR] 1.58, 95% CI 1.31-1.89), diabetes mellitus (OR 2.32, 95% CI 1.58-3.41), and obesity (OR 10.46, 95% CI 8.43-12.98). The effect of low fitness on cardiovascular events was no longer significant when including diabetes mellitus, hypercholesterolemia, and obesity as mediators (hazard ratio 0.99, 95% CI 0.82-1.19). The association between cardiovascular fitness and adverse cardiovascular outcomes may be modulated through traditional cardiovascular risk factors. These findings need to be further validated in prospective clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.
Seven-Year Efficacy of RTS,S/AS01 Malaria Vaccine among Young African Children.
Olotu, Ally; Fegan, Gregory; Wambua, Juliana; Nyangweso, George; Leach, Amanda; Lievens, Marc; Kaslow, David C; Njuguna, Patricia; Marsh, Kevin; Bejon, Philip
2016-06-30
The candidate malaria vaccine RTS,S/AS01 is being evaluated in order to inform a decision regarding its inclusion in routine vaccination schedules. We conducted 7 years of follow-up in children who had been randomly assigned, at 5 to 17 months of age, to receive three doses of either the RTS,S/AS01 vaccine or a rabies (control) vaccine. The end point was clinical malaria (temperature of ≥37.5°C and infection with Plasmodium falciparum of >2500 parasites per cubic millimeter). In an analysis that was not prespecified, the malaria exposure of each child was estimated with the use of information on the prevalence of malaria among residents within a 1-km radius of the child's home. Vaccine efficacy was defined as 1 minus the hazard ratio or the incidence-rate ratio, multiplied by 100, in the RTS,S/AS01 group versus the control group. Over 7 years of follow-up, we identified 1002 episodes of clinical malaria among 223 children randomly assigned to the RTS,S/AS01 group and 992 episodes among 224 children randomly assigned to the control group. The vaccine efficacy, as assessed by negative binomial regression, was 4.4% (95% confidence interval [CI], -17.0 to 21.9; P=0.66) in the intention-to-treat analysis and 7.0% (95% CI, -14.5 to 24.6; P=0.52) in the per-protocol analysis. Vaccine efficacy waned over time (P=0.006 for the interaction between vaccination and time), including negative efficacy during the fifth year among children with higher-than-average exposure to malaria parasites (intention-to-treat analysis: -43.5%; 95% CI, -100.3 to -2.8 [P=0.03]; per-protocol analysis: -56.8%; 95% CI, -118.7 to -12.3 [P=0.008]). A three-dose vaccination with RTS,S/AS01 was initially protective against clinical malaria, but this result was offset by rebound in later years in areas with higher-than-average exposure to malaria parasites. (Funded by the PATH Malaria Vaccine Initiative and others; ClinicalTrials.gov number, NCT00872963.).
1992-12-21
in preparation). Foundations of artificial intelligence. Cambridge, MA: MIT Press. O’Reilly, R. C. (1991). X3DNet: An X- Based Neural Network ...2.2.3 Trace based protocol analysis 19 2.2A Summary of important data features 21 2.3 Tools related to process model testing 23 2.3.1 Tools for building...algorithm 57 3. Requirements for testing process models using trace based protocol 59 analysis 3.1 Definition of trace based protocol analysis (TBPA) 59
Region-Based Collision Avoidance Beaconless Geographic Routing Protocol in Wireless Sensor Networks.
Lee, JeongCheol; Park, HoSung; Kang, SeokYoon; Kim, Ki-Il
2015-06-05
Due to the lack of dependency on beacon messages for location exchange, the beaconless geographic routing protocol has attracted considerable attention from the research community. However, existing beaconless geographic routing protocols are likely to generate duplicated data packets when multiple winners in the greedy area are selected. Furthermore, these protocols are designed for a uniform sensor field, so they cannot be directly applied to practical irregular sensor fields with partial voids. To prevent the failure of finding a forwarding node and to remove unnecessary duplication, in this paper, we propose a region-based collision avoidance beaconless geographic routing protocol to increase forwarding opportunities for randomly-deployed sensor networks. By employing different contention priorities into the mutually-communicable nodes and the rest of the nodes in the greedy area, every neighbor node in the greedy area can be used for data forwarding without any packet duplication. Moreover, simulation results are given to demonstrate the increased packet delivery ratio and shorten end-to-end delay, rather than well-referred comparative protocols.
Region-Based Collision Avoidance Beaconless Geographic Routing Protocol in Wireless Sensor Networks
Lee, JeongCheol; Park, HoSung; Kang, SeokYoon; Kim, Ki-Il
2015-01-01
Due to the lack of dependency on beacon messages for location exchange, the beaconless geographic routing protocol has attracted considerable attention from the research community. However, existing beaconless geographic routing protocols are likely to generate duplicated data packets when multiple winners in the greedy area are selected. Furthermore, these protocols are designed for a uniform sensor field, so they cannot be directly applied to practical irregular sensor fields with partial voids. To prevent the failure of finding a forwarding node and to remove unnecessary duplication, in this paper, we propose a region-based collision avoidance beaconless geographic routing protocol to increase forwarding opportunities for randomly-deployed sensor networks. By employing different contention priorities into the mutually-communicable nodes and the rest of the nodes in the greedy area, every neighbor node in the greedy area can be used for data forwarding without any packet duplication. Moreover, simulation results are given to demonstrate the increased packet delivery ratio and shorten end-to-end delay, rather than well-referred comparative protocols. PMID:26057037
Chian, Teo Chee; Nassir, Norziana Mat; Ibrahim, Mohd Izuan; Yusof, Ahmad Khairuddin Md
2017-01-01
Background This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. Methods Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. Results Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. Conclusions There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient. PMID:28275559
Saleem, Zikria; Ahmad, Mobasher; Hashmi, Furqan Khurshid; Saeed, Hamid; Aziz, Muhammad Tahir
2016-09-01
Doxorubicin and Cyclophosphamide (AC protocol) combination is usually considered as a first line therapy in newly diagnosed breast cancer patients. Thus, a retrospective observational study was conducted to monitor the effect of AC protocol on liver synthetic functions and production of plasma proteins in breast cancer patients, reporting to specialized cancer care hospital of Lahore, Pakistan. A total of 75 patients (n=75) on AC protocol with breast cancer were observed in this study. The patient data including age, gender, body surface area, dosage, disease status and laboratory biochemical values were recorded by reviewing historical treatment records. Pre-treatment values were taken as baseline values for albumin, globulin, blood urea nitrogen (BUN), albumin/globulin (A/G) ratio and total proteins. The baseline values were compared after each cycle of by applying ANOVA using statistical tool SPSS® version 21. The plasma levels of blood urea nitrogen (BUN), total protein and globulin dropped significantly (p<0.05) in patients of all age groups. However, the albumin levels were not significantly changed (p>0.05). The A/G ratio level increased (p<0.05) as a result of reduction in globulin levels. Significant changes in plasma protein levels were observed in the elderly patients (50 to 65 years) than patients between 20 to 50 years of age. AC protocol impairs liver synthetic functions as observed by decreased blood urea nitrogen (BUN) and plasma protein levels.
Annoni, Andrea Daniele; Mancini, Maria E; Andreini, Daniele; Formenti, Alberto; Mushtaq, Saima; Nobili, Enrica; Guglielmo, Marco; Baggiano, Andrea; Conte, Edoardo; Pepi, Mauro
2017-10-01
Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV. Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols. © 2017 The Royal Australian and New Zealand College of Radiologists.
Aouad, Marie T; Alfahel, Waseem S; Kaddoum, Roland N; Siddik-Sayyid, Sahar M
2017-04-11
Sugammadex reverses the effect of rocuronium more rapidly and effectively than neostigmine, at all levels of neuromuscular blockade (NMB). However, its cost is prohibitive. The combination of half dose sugammadex with neostigmine would be non-inferior to full dose sugammadex for the reversal of deep NMB. This approach would reduce the cost of sugammadex while preserving its efficacy. Patients were randomly allocated to receive sugammadex 4 mg/kg (Group S) or sugammadex 2 mg/kg with neostigmine 50 μg/kg and glycopyrrolate 10 μg/kg (Group NS) for reversal of rocuronium deep NMB. The primary outcome was the percentage of patients who recovered to 90% Train of Four (TOF) ratio within 5 min. The non-inferiority margin was set at 10%. Twenty eight patients were enrolled in each group. The number of patients who reached 90% TOF ratio within 5 min was 27 out of 28 (96%) in group S versus 25 out of 28 (89%) in group NS by intention-to-treat (difference: 7%, 95% CI of the difference: -9% to 24%). The number of patients who reached 90% TOF ratio within 5 min was 26 out of 26 (100%) in group S versus 23 out of 25 (92%) in group NS by per-protocol (difference: 8%, 95% CI of the difference: -6% to 25%). Sugammadex 2 mg/kg with neostigmine 50 μg/kg was at worst 9% and 6% less effective than sugammadex 4 mg/kg by intention-to-treat and by per-protocol analysis respectively. Hence, the combination is non-inferior to the recommended dose of sugammadex. Clinicaltrials.gov NCT 02375217 , registered on February 11, 2015.
NASA Technical Reports Server (NTRS)
Mueller, J. L. (Editor); Fargion, Giulietta S. (Editor); McClain, Charles R. (Editor)
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.
Protocol for Cohesionless Sample Preparation for Physical Experimentation
2016-05-01
protocol for specimen preparation that will enable the use of soil strength curves based on expedient field classification testing (e.g., grain-size...void ratio and relative compaction, which compares field compaction to a laboratory maximum density. Gradation charts for the two materials used in...the failure stress. Ring shear testing was performed using the GCTS Residual-Ring Shear System SRS-150 in order to measure the peak torsional
Distributed reservation control protocols for random access broadcasting channels
NASA Technical Reports Server (NTRS)
Greene, E. P.; Ephremides, A.
1981-01-01
Attention is given to a communication network consisting of an arbitrary number of nodes which can communicate with each other via a time-division multiple access (TDMA) broadcast channel. The reported investigation is concerned with the development of efficient distributed multiple access protocols for traffic consisting primarily of single packet messages in a datagram mode of operation. The motivation for the design of the protocols came from the consideration of efficient multiple access utilization of moderate to high bandwidth (4-40 Mbit/s capacity) communication satellite channels used for the transmission of short (1000-10,000 bits) fixed length packets. Under these circumstances, the ratio of roundtrip propagation time to packet transmission time is between 100 to 10,000. It is shown how a TDMA channel can be adaptively shared by datagram traffic and constant bandwidth users such as in digital voice applications. The distributed reservation control protocols described are a hybrid between contention and reservation protocols.
Rod Electroretinograms Elicited by Silent Substitution Stimuli from the Light-Adapted Human Eye
Maguire, John; Parry, Neil R. A.; Kremers, Jan; Kommanapalli, Deepika; Murray, Ian J.; McKeefry, Declan J.
2016-01-01
Purpose To demonstrate that silent substitution stimuli can be used to generate electroretinograms (ERGs) that effectively isolate rod photoreceptor function in humans without the need for dark adaptation, and that this approach constitutes a viable alternative to current clinical standard testing protocols. Methods Rod-isolating and non-isolating sinusoidal flicker stimuli were generated on a 4 primary light-emitting diode (LED) Ganzfeld stimulator to elicit ERGs from participants with normal and compromised rod function who had not undergone dark-adaptation. Responses were subjected to Fourier analysis, and the amplitude and phase of the fundamental were used to examine temporal frequency and retinal illuminance response characteristics. Results Electroretinograms elicited by rod-isolating silent substitution stimuli exhibit low-pass temporal frequency response characteristics with an upper response limit of 30 Hz. Responses are optimal between 5 and 8 Hz and between 10 and 100 photopic trolands (Td). There is a significant correlation between the response amplitudes obtained with the silent substitution method and current standard clinical protocols. Analysis of signal-to-noise ratios reveals significant differences between subjects with normal and compromised rod function. Conclusions Silent substitution provides an effective method for the isolation of human rod photoreceptor function in subjects with normal as well as compromised rod function when stimuli are used within appropriate parameter ranges. Translational Relevance This method of generating rod-mediated ERGs can be achieved without time-consuming periods of dark adaptation, provides improved isolation of rod- from cone-based activity, and will lead to the development of faster clinical electrophysiologic testing protocols with improved selectivity. PMID:27617180
Kooij, Marcel J.; Heerdink, Eibert R.; van Dijk, Liset; van Geffen, Erica C. G.; Belitser, Svetlana V.; Bouvy, Marcel L.
2016-01-01
Objectives: To assess the effect of a pharmacist telephone counseling intervention on patients' medication adherence. Design: Pragmatic cluster randomized controlled trial. Setting: 53 Community pharmacies in The Netherlands. Participants: Patients ≥18 years initiating treatment with antidepressants, bisphosphonates, Renin-Angiotensin System (RAS)-inhibitors, or statins (lipid lowering drugs). Pharmacies in arm A provided the intervention for antidepressants and bisphosphonates and usual care for RAS-inhibitors and statins. Pharmacies in arm B provided the intervention for RAS-inhibitors and statins and usual care for antidepressants and bisphosphonates. Intervention: Intervention consisted of a telephone counseling intervention 7–21 days after the start of therapy. Counseling included assessment of practical and perceptual barriers and provision of information and motivation. Main outcome measure: Primary outcome was refill adherence measured over 1 year expressed as continuous outcome and dichotomous (refill rate≥80%). Secondary outcome was discontinuation within 1 year. Results: In the control arms 3627 patients were eligible and in the intervention arms 3094 patients. Of the latter, 1054 patients (34%) received the intervention. Intention to treat analysis showed no difference in adherence rates between the intervention and the usual care arm (74.7%, SD 37.5 respectively 74.5%, 37.9). More patients starting with RAS-inhibitors had a refill ratio ≥80% in the intervention arm compared to usual care (81.4 vs. 74.9% with odds ratio (OR) 1.43, 95%CI 1.11–1.99). Comparing patients with counseling to patients with usual care (per protocol analysis), adherence was statistically significant higher for patients starting with RAS-inhibitors, statins and bisphosphonates. Patients initiating antidepressants did not benefit from the intervention. Conclusions: Telephone counseling at start of therapy improved adherence in patients initiating RAS-inhibitors. The per protocol analysis indicated an improvement for lipid lowering drugs and bisphosphonates. No effect for on adherence in patients initiating antidepressants was found. The trial was registered at www.trialregister.nl under the identifier NTR3237. PMID:27625605
2014-01-01
Background There is a high unmet need for effective treatments for patients with squamous non-small cell lung cancer (NSCLC). Eli Lilly and Company is conducting a phase III, randomized, multicenter, open-label study of gemcitabine plus cisplatin plus necitumumab (GC + N) versus gemcitabine plus cisplatin (GC) for the first-line treatment of patients with stage IV squamous NSCLC. Given GC is not the only treatment commonly used for the treatment of squamous NSCLC, this study was designed to compare the survival, toxicity, and quality of life outcomes of current treatment strategies for squamous NSCLC in the first-line setting. Methods/Design A systematic review and meta-analysis (including indirect comparisons) of treatments used in squamous NSCLC will be conducted to assess the clinical efficacy (overall and progression-free survival), health-related quality of life (HRQoL), and safety (grade 3–4 toxicity) of GC + N compared to other treatments used in squamous NSCLC. PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines will be followed for all aspects of this study. A systematic literature review will be conducted to identify randomized controlled trials evaluating chemotherapy treatment in first-line NSCLC. Eligible articles will be restricted to randomized controlled trials (RCTs) among chemotherapy-naïve advanced NSCLC cancer patients that report outcome data (survival, toxicity, or quality of life) for patients with squamous histology. Following data extraction and validation, data consistency and study heterogeneity will be assessed. A network meta-analysis will be conducted based on the available hazard ratios for overall and progression-free survival, odds ratios for published toxicity data, and mean difference of HRQoL scales. Sensitivity analyses will be conducted. Discussion This is a presentation of the study protocol only. Results and conclusions are pending completion of this study. Systematic review registration PROSPERO CRD42014008968 PMID:25227571
Choi, Jun Hwan; Kim, Bo Ryun; Joo, Seung Jae; Han, Eun Young; Kim, Song Yi; Kim, Sun Mi; Lee, So Young; Yoon, Ho Min
2015-01-01
To investigate cardiorespiratory responses during exercise stress tests using an aquatic treadmill and a land-based treadmill in patients with coronary artery disease (CAD). Twenty-one stable CAD patients were enrolled. All patients participated in 2 symptom-limited incremental exercise tests, using both an aquatic and a land treadmill. For the aquatic treadmill protocol, patients were submerged to the upper waist in 28°C water. The treadmill speed started at 2.0 km/h and increased 0.5 km/h every minute thereafter. For the land treadmill protocol, the speed and gradient were started at 2.4 km/h and 1.5%, respectively. The speed was increased by 0.3 km/h and grade by 1% every minute thereafter. Oxygen consumption ((Equation is included in full-text article.)O2), heart rate (HR), and respiratory exchange ratio were measured continuously and peak values recorded. Rating of perceived exertion, percentage of age-predicted maximal HR, and total exercise duration were also recorded. Peak cardiorespiratory responses during both protocols were compared. The peak (Equation is included in full-text article.)O2 and peak HR did not show any significant differences. The peak respiratory exchange ratio was significantly greater using the land treadmill than the aquatic treadmill protocol. Rating of perceived exertion, age-predicted maximal HR percentage, and total exercise duration were similar for both protocols. There was a significant linear relationship between HR and (Equation is included in full-text article.)O2 with both protocols. This study demonstrated that aquatic treadmill exercise elicits similar peak cardiorespiratory responses compared with land treadmill exercise, suggesting that aquatic treadmill exercise may be effective for CAD patients in cardiac rehabilitation.
Design and analysis issues for economic analysis alongside clinical trials.
Marshall, Deborah A; Hux, Margaret
2009-07-01
Clinical trials can offer a valuable and efficient opportunity to collect the health resource use and outcomes data for economic evaluation. However, economic and clinical studies differ fundamentally in the question they seek to answer. The design and analysis of trial-based cost-effectiveness studies require special consideration, which are reviewed in this article. Traditional randomized controlled trials, using an experimental design with a controlled protocol, are designed to measure safety and efficacy for product registration. Cost-effectiveness analysis seeks to measure effectiveness in the context of routine clinical practice, and requires collection of health care resources to allow estimation of cost over an equal timeframe for each treatment alternative. In assessing suitability of a trial for economic data collection, the comparator treatment and other protocol factors need to reflect current clinical practice and the trial follow-up must be sufficiently long to capture important costs and effects. The broadest available population and a measure of effectiveness reflecting important benefits for patients are preferred for economic analyses. Special analytical issues include dealing with missing and censored cost data, assessing uncertainty of the incremental cost-effectiveness ratio, and accounting for the underlying heterogeneity in patient subgroups. Careful consideration also needs to be given to data from multinational studies since practice patterns can differ across countries. Although clinical trials can be an efficient opportunity to collect data for economic evaluation, careful consideration of the suitability of the study design, and appropriate analytical methods must be applied to obtain rigorous results.
Zarb, Francis; McEntee, Mark F; Rainford, Louise
2015-06-01
To evaluate visual grading characteristics (VGC) and ordinal regression analysis during head CT optimisation as a potential alternative to visual grading assessment (VGA), traditionally employed to score anatomical visualisation. Patient images (n = 66) were obtained using current and optimised imaging protocols from two CT suites: a 16-slice scanner at the national Maltese centre for trauma and a 64-slice scanner in a private centre. Local resident radiologists (n = 6) performed VGA followed by VGC and ordinal regression analysis. VGC alone indicated that optimised protocols had similar image quality as current protocols. Ordinal logistic regression analysis provided an in-depth evaluation, criterion by criterion allowing the selective implementation of the protocols. The local radiology review panel supported the implementation of optimised protocols for brain CT examinations (including trauma) in one centre, achieving radiation dose reductions ranging from 24 % to 36 %. In the second centre a 29 % reduction in radiation dose was achieved for follow-up cases. The combined use of VGC and ordinal logistic regression analysis led to clinical decisions being taken on the implementation of the optimised protocols. This improved method of image quality analysis provided the evidence to support imaging protocol optimisation, resulting in significant radiation dose savings. • There is need for scientifically based image quality evaluation during CT optimisation. • VGC and ordinal regression analysis in combination led to better informed clinical decisions. • VGC and ordinal regression analysis led to dose reductions without compromising diagnostic efficacy.
Experience of implementing a National pre-hospital Code Red bleeding protocol in Scotland.
Reed, Matthew J; Glover, Alison; Byrne, Lauren; Donald, Michael; McMahon, Niall; Hughes, Neil; Littlewood, Nicola K; Garrett, Justin; Innes, Catherine; McGarvey, Margaret; Hazra, Eleanor; Rawlinson, P Sam M
2017-01-01
The Scottish Transfusion and Laboratory Support in Trauma Group (TLSTG) have introduced a unified National pre-hospital Code Red protocol. This paper reports the results of a study aiming to establish whether current pre-hospital Code Red activation criteria for trauma patients successfully predict need for in hospital transfusion or haemorrhagic death, the current admission coagulation profile and Concentrated Red Cell (CRC): Fresh Frozen Plasma (FFP) ratio being used, and whether use of the protocol leads to increased blood component discards? Prospective cohort study. Clinical and transfusion leads for each of Scotland's pre-hospital services and their receiving hospitals agreed to enter data into the study for all trauma patients for whom a pre-hospital Code Red was activated. Outcome data collected included survival 24h after Code Red activation, survival to hospital discharge, death in the Emergency Department and death in hospital. Between June 1st 2013 and October 31st 2015 there were 53 pre-hospital Code Red activations. Median Injury Severity Score (ISS) was 24 (IQR 14-37) and mortality 38%. 16 patients received pre-hospital blood. The pre-hospital Code Red protocol was sensitive for predicting transfusion or haemorrhagic death (89%). Sensitivity, specificity, positive and negative predictive values of the pre-hospital SBP <90mmHg component were 63%, 33%, 86% and 12%. 19% had an admission prothrombin time >14s and 27% had a fibrinogen <1.5g/L. CRC: FFP ratios did not drop to below 2:1 until 150min after arrival in the ED. 16 red cell units, 33 FFP and 6 platelets were discarded. This was not significantly increased compared to historical data. A National pre-hospital Code Red protocol is sensitive for predicting transfusion requirement in bleeding trauma patients and does not lead to increased blood component discards. A significant number of patients are coagulopathic and there is a need to improve CRC: FFP ratios and time to transfusion support especially FFP provision. Training clinicians to activate pre-hospital Code Red earlier during the pre-hospital phase may give blood bank more time to thaw and prepare FFP and may improve FFP administration times and ratios so long as components are used upon their availability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Influence of signal intensity non-uniformity on brain volumetry using an atlas-based method.
Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni
2012-01-01
Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.
Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method
Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni
2012-01-01
Objective Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Materials and Methods Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. Results A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. Conclusion The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials. PMID:22778560
Ratkevicius, A; Skurvydas, A; Povilonis, E; Quistorff, B; Lexell, J
1998-04-01
The aims of this study were to investigate if low-frequency fatigue (LFF) dependent on the duration of repeated muscle contractions and to compare LFF in voluntary and electrically induced exercise. Male subjects performed three 9-min periods of repeated isometric knee extensions at 40% maximal voluntary contraction with contraction plus relaxation periods of 30 plus 60 s, 15 plus 30 s and 5 plus 10 s in protocols 1, 2 and 3, respectively. The same exercise protocols were repeated using feedback-controlled electrical stimulation at 40% maximal tetanic torque. Before and 15 min after each exercise period, knee extension torque at 1, 7, 10, 15, 20, 50 and 100 Hz was assessed. During voluntary exercise, electromyogram root mean square (EMGrms) of the vastus lateralis muscle was evaluated. The 20-Hz torque:100-Hz torque (20:100 Hz torque) ratio was reduced more after electrically induced than after voluntary exercise (P < 0.05). During electrically induced exercise, the decrease in 20:100 Hz torque ratio was gradually (P < 0.05) reduced as the individual contractions shortened. During voluntary exercise, the decrease in 20:100 Hz torque ratio and the increase in EMGrms were greater in protocol 1 (P < 0.01) than in protocols 2 and 3, which did not differ from each other. In conclusion, our results showed that LFF is dependent on the duration of individual muscle contractions during repetitive isometric exercise and that the electrically induced exercise produced a more pronounced LFF compared to voluntary exercise of submaximal intensity. It is suggested that compensatory recruitment of faster-contracting motor units is an additional factor affecting the severity of LFF during voluntary exercise.
Yokoyama, Hikaru; Sato, Koji; Ogawa, Tetsuya; Yamamoto, Shin-Ichiro; Nakazawa, Kimitaka; Kawashima, Noritaka
2018-01-01
The adaptability of human bipedal locomotion has been studied using split-belt treadmill walking. Most of previous studies utilized experimental protocol under remarkably different split ratios (e.g. 1:2, 1:3, or 1:4). While, there is limited research with regard to adaptive process under the small speed ratios. It is important to know the nature of adaptive process under ratio smaller than 1:2, because systematic evaluation of the gait adaptation under small to moderate split ratios would enable us to examine relative contribution of two forms of adaptation (reactive feedback and predictive feedforward control) on gait adaptation. We therefore examined a gait behavior due to on split-belt treadmill adaptation under five belt speed difference conditions (from 1:1.2 to 1:2). Gait parameters related to reactive control (stance time) showed quick adjustments immediately after imposing the split-belt walking in all five speed ratios. Meanwhile, parameters related to predictive control (step length and anterior force) showed a clear pattern of adaptation and subsequent aftereffects except for the 1:1.2 adaptation. Additionally, the 1:1.2 ratio was distinguished from other ratios by cluster analysis based on the relationship between the size of adaptation and the aftereffect. Our findings indicate that the reactive feedback control was involved in all the speed ratios tested and that the extent of reaction was proportionally dependent on the speed ratio of the split-belt. On the contrary, predictive feedforward control was necessary when the ratio of the split-belt was greater. These results enable us to consider how a given split-belt training condition would affect the relative contribution of the two strategies on gait adaptation, which must be considered when developing rehabilitation interventions for stroke patients.
Optimization of image quality in pulmonary CT angiography with low dose of contrast material
NASA Astrophysics Data System (ADS)
Assi, Abed Al Nasser; Abu Arra, Ali
2017-06-01
Aim: The aim of this study was to compare objective image quality data for patient pulmonary embolism between a conventional pulmonary CTA protocol with respect to a novel acquisition protocol performed with optimize radiation dose and less amount of iodinated contrast medium injected to the patients during PE scanning. Materials and Methods: Sixty- four patients with Pulmonary Embolism (PE) possibility, were examined using angio-CT protocol. Patients were randomly assigned to two groups: A (16 women and 16 men, with age ranging from 19-89 years) mean age, 62 years with standard deviation 16; range, 19-89 years) - injected contrast agent: 35-40 ml. B (16 women and 16 men, with age ranging from 28-86 years) - injected contrast agent: 70-80 ml. Other scanning parameters were kept constant. Pulmonary vessel enhancement and image noise were quantified; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective vessel contrast was assessed by two radiologists in consensus. Result: A total of 14 cases of PE (22 %) were found in the evaluated of subjects (nine in group A, and five in group B). All PE cases were detected by the two readers. There was no significant difference in the size or location of the PEs between the two groups, the average image noise was 14 HU for group A and 19 HU for group B. The difference was not statistically significant (p = 0.09). Overall, the SNR and CNR were slightly higher on group B (24.4 and 22.5 respectively) compared with group A (19.4 and 16.4 respectively), but those differences were not statistically significant (p = 0.71 and p = 0.35, respectively). Conclusion and Discussion: Both groups that had been evaluated by pulmonary CTA protocol allow similar image quality to be achieved as compared with each other's, with optimize care dose for both protocol and contrast volume were reduced by 50 % in new protocol comparing to the conventional protocol.
Mahalingam, Harshavardhan; Lal, Anupam; Mandal, Arup K; Singh, Shrawan Kumar; Bhattacharyya, Shalmoli; Khandelwal, Niranjan
2015-08-01
This study aimed to assess the accuracy of low-dose dual-energy computed tomography (DECT) in predicting the composition of urinary calculi. A total of 52 patients with urinary calculi were scanned with a 128-slice dual-source DECT scanner by use of a low-dose protocol. Dual-energy (DE) ratio, weighted average Hounsfield unit (HU) of calculi, radiation dose, and image noise levels were recorded. Two radiologists independently rated study quality. Stone composition was assessed after extraction by Fourier transform infrared spectroscopy (FTIRS). Analysis of variance was used to determine if the differences in HU values and DE ratios between the various calculus groups were significant. Threshold cutoff values to classify the calculi into separate groups were identified by receiver operating characteristic curve analysis. A total of 137 calculi were detected. FTIRS analysis differentiated the calculi into five groups: uric acid (n=17), struvite (n=3), calcium oxalate monohydrate and dihydrate (COM-COD, n=84), calcium oxalate monohydrate (COM, n=28), and carbonate apatite (n=5). The HU value could differentiate only uric acid calculi from calcified calculi (p<0.001). The DE ratio could confidently differentiate uric acid, struvite, calcium oxalate, and carbonate apatite calculi (p<0.001) with cutoff values of 1.12, 1.34, and 1.66, respectively, giving >80% sensitivity and specificity to differentiate them. The DE ratio could not differentiate COM from COM-COD calculi. No study was rated poor in quality by either of the observers. The mean radiation dose was 1.8 mSv. Low-dose DECT accurately predicts urinary calculus composition in vivo while simultaneously reducing radiation exposure without compromising study quality.
Measuring Audience Engagement for Public Health Twitter Chats: Insights From #LiveFitNOLA
Croston, Merriah A
2017-01-01
Background Little empirical evidence exists on the effectiveness of using Twitter as a two-way communication tool for public health practice, such as Twitter chats. Objective We analyzed whether Twitter chats facilitate engagement in two-way communications between public health entities and their audience. We also describe how to measure two-way communications, incoming and outgoing mentions, between users in a protocol using free and publicly available tools (Symplur, OpenRefine, and Gephi). Methods We used a mixed-methods approach, social network analysis, and content analysis. The study population comprised individuals and organizations participating or who were mentioned in the first #LiveFitNOLA chat, during a 75-min period on March 5, 2015, from 12:00 PM to 1:15 PM Central Time. We assessed audience engagement in two-way communications with two metrics: engagement ratio and return on engagement (ROE). Results The #LiveFitNOLA chat had 744 tweets and 66 participants with an average of 11 tweets per participant. The resulting network had 134 network members and 474 engagements. The engagement ratios and ROEs for the #LiveFitNOLA organizers were 1:1, 40% (13/32) (@TulanePRC) and 2:1, −40% (−25/63) (@FitNOLA). Content analysis showed information sharing (63.9%, 314/491) and health information (27.9%, 137/491) as the most salient theme and sub-theme, respectively. Conclusions Our findings suggest Twitter chats facilitate audience engagement in two-way communications between public health entities and their audience. The #LiveFitNOLA organizers’ engagement ratios and ROEs indicated a moderate level of engagement with their audience. The practical significance of the engagement ratio and ROE depends on the audience, context, scope, scale, and goal of a Twitter chat or other organized hashtag-based communications on Twitter. PMID:28596149
Mahalingam, Harshavardhan; Mandal, Arup K; Singh, Shrawan Kumar; Bhattacharyya, Shalmoli; Khandelwal, Niranjan
2015-01-01
Purpose This study aimed to assess the accuracy of low-dose dual-energy computed tomography (DECT) in predicting the composition of urinary calculi. Materials and Methods A total of 52 patients with urinary calculi were scanned with a 128-slice dual-source DECT scanner by use of a low-dose protocol. Dual-energy (DE) ratio, weighted average Hounsfield unit (HU) of calculi, radiation dose, and image noise levels were recorded. Two radiologists independently rated study quality. Stone composition was assessed after extraction by Fourier transform infrared spectroscopy (FTIRS). Analysis of variance was used to determine if the differences in HU values and DE ratios between the various calculus groups were significant. Threshold cutoff values to classify the calculi into separate groups were identified by receiver operating characteristic curve analysis. Results A total of 137 calculi were detected. FTIRS analysis differentiated the calculi into five groups: uric acid (n=17), struvite (n=3), calcium oxalate monohydrate and dihydrate (COM-COD, n=84), calcium oxalate monohydrate (COM, n=28), and carbonate apatite (n=5). The HU value could differentiate only uric acid calculi from calcified calculi (p<0.001). The DE ratio could confidently differentiate uric acid, struvite, calcium oxalate, and carbonate apatite calculi (p<0.001) with cutoff values of 1.12, 1.34, and 1.66, respectively, giving >80% sensitivity and specificity to differentiate them. The DE ratio could not differentiate COM from COM-COD calculi. No study was rated poor in quality by either of the observers. The mean radiation dose was 1.8 mSv. Conclusions Low-dose DECT accurately predicts urinary calculus composition in vivo while simultaneously reducing radiation exposure without compromising study quality. PMID:26279828
A Logical Analysis of Quantum Voting Protocols
NASA Astrophysics Data System (ADS)
Rad, Soroush Rafiee; Shirinkalam, Elahe; Smets, Sonja
2017-12-01
In this paper we provide a logical analysis of the Quantum Voting Protocol for Anonymous Surveying as developed by Horoshko and Kilin in (Phys. Lett. A 375, 1172-1175 2011). In particular we make use of the probabilistic logic of quantum programs as developed in (Int. J. Theor. Phys. 53, 3628-3647 2014) to provide a formal specification of the protocol and to derive its correctness. Our analysis is part of a wider program on the application of quantum logics to the formal verification of protocols in quantum communication and quantum computation.
An Evaluation Methodology for Protocol Analysis Systems
2007-03-01
Main Memory Requirement NS: Needham-Schroeder NSL: Needham-Schroeder-Lowe OCaml : Objective Caml POSIX: Portable Operating System...methodology is needed. A. PROTOCOL ANALYSIS FIELD As with any field, there is a specialized language used within the protocol analysis community. Figure...ProVerif requires that Objective Caml ( OCaml ) be installed on the system, OCaml version 3.09.3 was installed. C. WINDOWS CONFIGURATION OS
Laumbach, Robert J.; Rich, David Q.; Gandhi, Sampada; Amorosa, Louis; Schneider, Stephen; Zhang, Junfeng; Ohman-Strickland, Pamela; Gong, Jicheng; Lelyanov, Oleksiy; Kipen, Howard M.
2014-01-01
Objective To pilot a protocol to evaluate acute cardiovascular effects in in-vehicle exposure to traffic air pollutants in people with diabetes. Methods Twenty-one volunteers with type 2 diabetes were passengers on 90- to 110-minute car rides on a busy highway. We measured in-vehicle particle number and mass (PM2.5) nitrogen dioxide, and carbon monoxide and heart rate, heart rate variability (HRV), and blood pressure. Results Compared with pre-ride measurements, we found a decrease in high frequency (HF) HRV from pre-ride to next day (ratio 0.66, 95% CI = 0.47 to 0.93) and an increase in low frequency to HF ratio at post-ride (ratio 1.92, 95% CI = 1.21 to 3.05) at post-ride. Interquartile range increases in measured pollutants were associated with next-day decreases in HR HRV. Conclusions This protocol appears useful for assessing acute adverse cardiovascular effects of in-vehicle exposures among people who have diabetes. PMID:20190650
Optimization of the quenching method for metabolomics analysis of Lactobacillus bulgaricus.
Chen, Ming-ming; Li, Ai-li; Sun, Mao-cheng; Feng, Zhen; Meng, Xiang-chen; Wang, Ying
2014-04-01
This study proposed a quenching protocol for metabolite analysis of Lactobacillus delbrueckii subsp. bulgaricus. Microbial cells were quenched with 60% methanol/water, 80% methanol/glycerol, or 80% methanol/water. The effect of the quenching process was assessed by the optical density (OD)-based method, flow cytometry, and gas chromatography-mass spectrometry (GC-MS). The principal component analysis (PCA) and orthogonal partial least squares-discriminant analysis (OPLS-DA) were employed for metabolite identification. The results indicated that quenching with 80% methanol/water solution led to less damage to the L. bulgaricus cells, characterized by the lower relative fraction of prodium iodide (PI)-labeled cells and the higher OD recovery ratio. Through GC-MS analysis, higher levels of intracellular metabolites (including focal glutamic acid, aspartic acid, alanine, and AMP) and a lower leakage rate were detected in the sample quenched with 80% methanol/water compared with the others. In conclusion, we suggested a higher concentration of cold methanol quenching for L. bulgaricus metabolomics due to its decreasing metabolite leakage.
Optimization of the quenching method for metabolomics analysis of Lactobacillus bulgaricus *
Chen, Ming-ming; Li, Ai-li; Sun, Mao-cheng; Feng, Zhen; Meng, Xiang-chen; Wang, Ying
2014-01-01
This study proposed a quenching protocol for metabolite analysis of Lactobacillus delbrueckii subsp. bulgaricus. Microbial cells were quenched with 60% methanol/water, 80% methanol/glycerol, or 80% methanol/water. The effect of the quenching process was assessed by the optical density (OD)-based method, flow cytometry, and gas chromatography-mass spectrometry (GC-MS). The principal component analysis (PCA) and orthogonal partial least squares-discriminant analysis (OPLS-DA) were employed for metabolite identification. The results indicated that quenching with 80% methanol/water solution led to less damage to the L. bulgaricus cells, characterized by the lower relative fraction of prodium iodide (PI)-labeled cells and the higher OD recovery ratio. Through GC-MS analysis, higher levels of intracellular metabolites (including focal glutamic acid, aspartic acid, alanine, and AMP) and a lower leakage rate were detected in the sample quenched with 80% methanol/water compared with the others. In conclusion, we suggested a higher concentration of cold methanol quenching for L. bulgaricus metabolomics due to its decreasing metabolite leakage. PMID:24711354
Riaz, Irbaz Bin; Dhoble, Abhijeet; Mizyed, Ahmad; Hsu, Chiu-Hsieh; Husnain, Muhammad; Lee, Justin Z; Lotun, Kapildeo; Lee, Kwan S
2013-12-11
There is an association between cryptogenic stroke and patent foramen ovale (PFO). The optimal treatment strategy for secondary prevention remains unclear. The purpose of this study was to analyze aggregate data examining the safety and efficacy of transcatheter device closure versus standard medical therapy in patients with PFO and cryptogenic stroke. A search of published data identified 3 randomized clinical trials for inclusion. The primary outcome was a composite end-point of death, stroke and transient-ischemic attack (TIA). Pre-defined subgroup analysis was performed with respect to baseline characteristics including age, sex, atrial septal aneurysm and shunt size. Data was synthesized using a random effects model and results presented as hazard ratios (HRs) with 95% confidence intervals (CIs). A cohort of 2,303 patients with a history of cryptogenic stroke and PFO were randomized to device closure (n = 1150) and medical therapy (n = 1153). Mean follow-up was 2.5 years. Transcatheter closure was not superior to medical therapy in the secondary prevention of stroke or TIA in intention-to-treat analysis (HR: 0.66, 95% CI: 0.43 to 1.01; p = 0.056). However, the results were statistically significant using per-protocol analysis (HR: 0.64, 95% CI: 0.41 to 0.98; p = 0.043). Males had significant benefit with device closure (HR: 0.48, 95% CI: 0.24 to 0.96; p = 0.038). In this meta-analysis, using intention-to-treat analysis, transcatheter device closure of PFO was not superior to standard medical therapy in the secondary prevention of cryptogenic stroke. Transcatheter closure was superior using per-protocol analysis.
2015-09-01
Gateway 2 4. Voice Packet Flow: SIP , Session Description Protocol (SDP), and RTP 3 5. Voice Data Analysis 5 6. Call Analysis 6 7. Call Metrics 6...analysis processing is designed for a general VoIP system architecture based on Session Initiation Protocol ( SIP ) for negotiating call sessions and...employs Skinny Client Control Protocol for network communication between the phone and the local CallManager (e.g., for each dialed digit), SIP
NHEXAS PHASE I MARYLAND STUDY--LIST OF AVAILABLE DOCUMENTS: PROTOCOLS AND SOPS
This document lists available protocols and SOPs for the NHEXAS Phase I Maryland study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis and general laboratory procedures, (3) Data Analysis Proced...
Henzl, Michael T; Markus, Lindsey A; Davis, Meredith E; McMillan, Andrew T
2013-03-01
Capable of providing a detailed thermodynamic picture of noncovalent association reactions, isothermal titration calorimetry (ITC) has become a popular method for studying protein-ligand interactions. We routinely employ the technique to study divalent ion-binding by two-site EF-hand proteins from the parvalbumin- and polcalcin lineages. The combination of high Ca(2+) affinity and relatively low Mg(2+) affinity, and the attendant complication of parameter correlation, conspire to make the simultaneous extraction of binding constants and -enthalpies for both ions challenging. Although global analysis of multiple ITC experiments can overcome these hurdles, our current experimental protocol includes upwards of 10 titrations - requiring a substantial investment in labor, machine time, and material. This paper explores the potential for using a smaller suite of experiments that includes simultaneous titrations with Ca(2+) and Mg(2+) at different ratios of the two ions. The results obtained for four proteins, differing substantially in their divalent ion-binding properties, suggest that the approach has merit. The Ca(2+)- and Mg(2+)-binding constants afforded by the streamlined analysis are in reasonable agreement with those obtained from the standard analysis protocol. Likewise, the abbreviated analysis provides comparable values for the Ca(2+)-binding enthalpies. However, the streamlined analysis can yield divergent values for the Mg(2+)-binding enthalpies - particularly those for lower affinity sites. This shortcoming can be remedied, in large measure, by including data from a direct Ca(2+) titration in the presence of a high, fixed Mg(2+) concentration. Copyright © 2013. Published by Elsevier Inc.
A framework for the definition of standardized protocols for measuring upper-extremity kinematics.
Kontaxis, A; Cutti, A G; Johnson, G R; Veeger, H E J
2009-03-01
Increasing interest in upper extremity biomechanics has led to closer investigations of both segment movements and detailed joint motion. Unfortunately, conceptual and practical differences in the motion analysis protocols used up to date reduce compatibility for post data and cross validation analysis and so weaken the body of knowledge. This difficulty highlights a need for standardised protocols, each addressing a set of questions of comparable content. The aim of this work is therefore to open a discussion and propose a flexible framework to support: (1) the definition of standardised protocols, (2) a standardised description of these protocols, and (3) the formulation of general recommendations. Proposal of a framework for the definition of standardized protocols. The framework is composed by two nested flowcharts. The first defines what a motion analysis protocol is by pointing out its role in a motion analysis study. The second flowchart describes the steps to build a protocol, which requires decisions on the joints or segments to be investigated and the description of their mechanical equivalent model, the definition of the anatomical or functional coordinate frames, the choice of marker or sensor configuration and the validity of their use, the definition of the activities to be measured and the refinements that can be applied to the final measurements. Finally, general recommendations are proposed for each of the steps based on the current literature, and open issues are highlighted for future investigation and standardisation. Standardisation of motion analysis protocols is urgent. The proposed framework can guide this process through the rationalisation of the approach.
Cirrus: Inducing Subject Models from Protocol Data
1988-08-16
behavior scientists, and more recently, by knowledge engineers who wish to embed the knowledge of human experts in an expert system. However, protocol...analysis is notoriously difficult and time comsuming . Several systems have been developed to aid in protocol analysis. Waterman and Newell (1971, 1973...developed a system that could read the natural langauge of the protocol and produce a formal trace of it (a problem behavior graph). The system, however
Asymptotically optimal data analysis for rejecting local realism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yanbao; Applied and Computational Mathematics Division, National Institute of Standards and Technology, Boulder, Colorado 80305; Glancy, Scott
2011-12-15
Reliable experimental demonstrations of violations of local realism are highly desirable for fundamental tests of quantum mechanics. One can quantify the violation witnessed by an experiment in terms of a statistical p value, which can be defined as the maximum probability according to local realism of a violation at least as high as that witnessed. Thus, high violation corresponds to small p value. We propose a prediction-based-ratio (PBR) analysis protocol whose p values are valid even if the prepared quantum state varies arbitrarily and local realistic models can depend on previous measurement settings and outcomes. It is therefore not subjectmore » to the memory loophole [J. Barrett et al., Phys. Rev. A 66, 042111 (2002)]. If the prepared state does not vary in time, the p values are asymptotically optimal. For comparison, we consider protocols derived from the number of standard deviations of violation of a Bell inequality and from martingale theory [R. Gill, e-print arXiv:quant-ph/0110137]. We find that the p values of the former can be too small and are therefore not statistically valid, while those derived from the latter are suboptimal. PBR p values do not require a predetermined Bell inequality and can be used to compare results from different tests of local realism independent of experimental details.« less
Inter-laboratory validation of bioaccessibility testing for metals.
Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R
2014-10-01
Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.
Feasible logic Bell-state analysis with linear optics
Zhou, Lan; Sheng, Yu-Bo
2016-01-01
We describe a feasible logic Bell-state analysis protocol by employing the logic entanglement to be the robust concatenated Greenberger-Horne-Zeilinger (C-GHZ) state. This protocol only uses polarization beam splitters and half-wave plates, which are available in current experimental technology. We can conveniently identify two of the logic Bell states. This protocol can be easily generalized to the arbitrary C-GHZ state analysis. We can also distinguish two N-logic-qubit C-GHZ states. As the previous theory and experiment both showed that the C-GHZ state has the robustness feature, this logic Bell-state analysis and C-GHZ state analysis may be essential for linear-optical quantum computation protocols whose building blocks are logic-qubit entangled state. PMID:26877208
Feasible logic Bell-state analysis with linear optics.
Zhou, Lan; Sheng, Yu-Bo
2016-02-15
We describe a feasible logic Bell-state analysis protocol by employing the logic entanglement to be the robust concatenated Greenberger-Horne-Zeilinger (C-GHZ) state. This protocol only uses polarization beam splitters and half-wave plates, which are available in current experimental technology. We can conveniently identify two of the logic Bell states. This protocol can be easily generalized to the arbitrary C-GHZ state analysis. We can also distinguish two N-logic-qubit C-GHZ states. As the previous theory and experiment both showed that the C-GHZ state has the robustness feature, this logic Bell-state analysis and C-GHZ state analysis may be essential for linear-optical quantum computation protocols whose building blocks are logic-qubit entangled state.
Optimizing otoacoustic emission protocols for a UNHS program.
Hatzopoulos, S; Petruccelli, J; Ciorba, A; Martini, A
2009-01-01
To identify the optimal test protocol to screen for hearing problems in newborns, an evaluation of three distortion product otoacoustic emission (DPOAE) protocols was conducted in neonates, from a well-baby nursery (WBN) and from a neonatal intensive care unit (NICU) and compared to the performance in newborns of a more standard protocol based on transient-evoked OAEs (TEOAEs). The DPOAE protocols used asymmetrical stimulus intensities (L(1) > L(2)) with a frequency ratio of 1.22, in the following format: (P1), L(1) = 60, L(2) = 50 dB SPL; (P2), L(1) = 65, L(2) = 55 dB SPL, and (P3), L(1) = 75, L(2) = 65 dB SPL. Linear TEOAE responses, evoked by click stimuli of 75 dB peSPL, were used as controls of normal cochlear function. Five frequencies at 1.5, 2.0, 3.0, 4.0 and 5.0 kHz were tested with a common commercially available macro-based software subroutine (Otodynamics Corp, ILO-92). The project evaluated the responses from 1200 WBN infants (average age 48 h) and 350 low-birth-weight NICU infants, all randomly selected. Statistical analyses comparing the signal-to-noise ratios (S/N), at the predefined f(2) frequencies, indicated that the P1 and P2 DPOAE protocols generated similar responses. Significant S/N differences were observed in the P3 to P2 dataset comparisons. DPOAE scoring criteria were estimated from the P3 dataset using a one-sided, distribution-free confidence intervals. The scoring criteria for a 'pass' were estimated as a minimum S/N of 6.0, 7.0 and 6.0 dB at 2.0, 3.0 and 4.0 kHz, respectively. In terms of feasibility, the P3 protocol generated responses in 98% of the WBN and 94.8% of the NICU infants. All three DPOAE protocols demonstrated shorter time-recording requirements than the standard TEOAE test. The false-positive and false-negative rates for the NICU infants were estimated as 0.0028 and 0.003%, respectively.
Genome-wide analysis of replication timing by next-generation sequencing with E/L Repli-seq.
Marchal, Claire; Sasaki, Takayo; Vera, Daniel; Wilson, Korey; Sima, Jiao; Rivera-Mulia, Juan Carlos; Trevilla-García, Claudia; Nogues, Coralin; Nafie, Ebtesam; Gilbert, David M
2018-05-01
This protocol is an extension to: Nat. Protoc. 6, 870-895 (2014); doi:10.1038/nprot.2011.328; published online 02 June 2011Cycling cells duplicate their DNA content during S phase, following a defined program called replication timing (RT). Early- and late-replicating regions differ in terms of mutation rates, transcriptional activity, chromatin marks and subnuclear position. Moreover, RT is regulated during development and is altered in diseases. Here, we describe E/L Repli-seq, an extension of our Repli-chip protocol. E/L Repli-seq is a rapid, robust and relatively inexpensive protocol for analyzing RT by next-generation sequencing (NGS), allowing genome-wide assessment of how cellular processes are linked to RT. Briefly, cells are pulse-labeled with BrdU, and early and late S-phase fractions are sorted by flow cytometry. Labeled nascent DNA is immunoprecipitated from both fractions and sequenced. Data processing leads to a single bedGraph file containing the ratio of nascent DNA from early versus late S-phase fractions. The results are comparable to those of Repli-chip, with the additional benefits of genome-wide sequence information and an increased dynamic range. We also provide computational pipelines for downstream analyses, for parsing phased genomes using single-nucleotide polymorphisms (SNPs) to analyze RT allelic asynchrony, and for direct comparison to Repli-chip data. This protocol can be performed in up to 3 d before sequencing, and requires basic cellular and molecular biology skills, as well as a basic understanding of Unix and R.
A Tree Based Broadcast Scheme for (m, k)-firm Real-Time Stream in Wireless Sensor Networks
Park, HoSung; Kim, Beom-Su; Kim, Kyong Hoon; Shah, Babar; Kim, Ki-Il
2017-01-01
Recently, various unicast routing protocols have been proposed to deliver measured data from the sensor node to the sink node within the predetermined deadline in wireless sensor networks. In parallel with their approaches, some applications demand the specific service, which is based on broadcast to all nodes within the deadline, the feasible real-time traffic model and improvements in energy efficiency. However, current protocols based on either flooding or one-to-one unicast cannot meet the above requirements entirely. Moreover, as far as the authors know, there is no study for the real-time broadcast protocol to support the application-specific traffic model in WSN yet. Based on the above analysis, in this paper, we propose a new (m, k)-firm-based Real-time Broadcast Protocol (FRBP) by constructing a broadcast tree to satisfy the (m, k)-firm, which is applicable to the real-time model in resource-constrained WSNs. The broadcast tree in FRBP is constructed by the distance-based priority scheme, whereas energy efficiency is improved by selecting as few as nodes on a tree possible. To overcome the unstable network environment, the recovery scheme invokes rapid partial tree reconstruction in order to designate another node as the parent on a tree according to the measured (m, k)-firm real-time condition and local states monitoring. Finally, simulation results are given to demonstrate the superiority of FRBP compared to the existing schemes in terms of average deadline missing ratio, average throughput and energy consumption. PMID:29120404
[Endovascular treatment in acute ischaemic stroke. A stroke care plan for the region of Madrid].
Alonso de Leciñana, M; Díaz-Guzmán, J; Egido, J A; García Pastor, A; Martínez-Sánchez, P; Vivancos, J; Díez-Tejedor, E
2013-09-01
Endovascular therapies (intra-arterial thrombolysis and mechanical thrombectomy) after acute ischaemic stroke are being implemented in the clinical setting even as they are still being researched. Since we lack sufficient data to establish accurate evidence-based recommendations for use of these treatments, we must develop clinical protocols based on current knowledge and carefully monitor all procedures. After review of the literature and holding work sessions to reach a consensus among experts, we developed a clinical protocol including indications and contraindications for endovascular therapies use in acute ischaemic stroke. The protocol includes methodology recommendations for diagnosing and selecting patients, performing revascularisation procedures, and for subsequent patient management. Its objective is to increase the likelihood of efficacy and treatment benefit and minimise risk of complications and ineffective recanalisation. Based on an analysis of healthcare needs and available resources, a cooperative inter-hospital care system has been developed. This helps to ensure availability of endovascular therapies to all patients, a fast response time, and a good cost-to-efficacy ratio. It includes also a prospective register which serves to monitor procedures in order to identify any opportunities for improvement. Implementation of endovascular techniques for treating acute ischaemic stroke requires the elaboration of evidence-based clinical protocols and the establishment of appropriate cooperative healthcare networks guaranteeing both the availability and the quality of these actions. Such procedures must be monitored in order to improve methodology. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Migliozzi, D.; Nguyen, H. T.; Gijs, M. A. M.
2018-02-01
Immunohistochemistry (IHC) is one of the main techniques currently used in the clinics for biomarker characterization. It consists in colorimetric labeling with specific antibodies followed by microscopy analysis. The results are then used for diagnosis and therapeutic targeting. Well-known drawbacks of such protocols are their limited accuracy and precision, which prevent the clinicians from having quantitative and robust IHC results. With our work, we combined rapid microfluidic immunofluorescent staining with efficient image-based cell segmentation and signal quantification to increase the robustness of both experimental and analytical protocols. The experimental protocol is very simple and based on fast-fluidic-exchange in a microfluidic chamber created on top of the formalin-fixed-paraffin-embedded (FFPE) slide by clamping it a silicon chip with a polydimethyl siloxane (PDMS) sealing ring. The image-processing protocol is based on enhancement and subsequent thresholding of the local contrast of the obtained fluorescence image. As a case study, given that the human epidermal growth factor receptor 2 (HER2) protein is often used as a biomarker for breast cancer, we applied our method to HER2+ and HER2- cell lines. We report very fast (5 minutes) immunofluorescence staining of both HER2 and cytokeratin (a marker used to define the tumor region) on FFPE slides. The image-processing program can segment cells correctly and give a cell-based quantitative immunofluorescent signal. With this method, we found a reproducible well-defined separation for the HER2-to-cytokeratin ratio for positive and negative control samples.
Couderc, Carine; Nappez, Claude; Drancourt, Michel
2012-03-30
It is recommended that harmful Biosafety Level 3 (BSL-3) bacteria be inactivated prior to identification by mass spectrometry, yet optimal effects of inactivation protocol have not been defined. Here, we compare trifluoroacetic acid inactivation (protocol A) with ethanol inactivation (protocol B) of Yersinia organisms prior to identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The total number of peaks detected was 10.5 ± 1.7 for protocol A and 15.7 ± 4.2 for protocol B (ρ <0.001, ANOVA test). The signal-to-noise ratio for the m/z 6049 peak present in all of the tested Yersinia isolates was 9.7 ± 3.1 for protocol A and 18.1 ± 4.6 for protocol B (ρ < 0.001). Compared with spectra in our local database containing 48 Yersinia spp., including 20 strains of Y. pestis, the identification score was 1.79 ± 0.2 for protocol A and 1.97 ± 0.19 for protocol B (ρ = 0.0024). Our observations indicate that for the identification of Yersinia organisms, ethanol inactivation yielded MALDI-TOF-MS spectra of significantly higher quality than spectra derived from trifluoroacetic acid inactivation. Combined with previously published data, our results permit the updating of protocols for inactivating BSL-3 bacteria. Copyright © 2012 John Wiley & Sons, Ltd.
Yang, J Y; Ruiz, M; Calnon, D A; Watson, D D; Beller, G A; Glover, D K
1999-05-01
123I-labeled iodophenylpentadecanoic acid (IPPA) is a synthetic fatty acid that may be useful for determination of myocardial viability. We investigated the uptake and clearance kinetics of this tracer in canine models of ischemia and infarction. In protocol 1, 185 MBq (5 mCi) 123I-IPPA were injected intravenously in 19 dogs with 50% left anterior descending artery (LAD) flow reduction. In 9 dogs, 201TI was coinjected. In protocol 2, 5 dogs underwent LAD occlusion for 3 h, and 123I-IPPA was injected 60 min after reperfusion. All dogs had flow measured by microspheres, regional systolic thickening by ultrasonic crystals and measurements of postmortem risk area and infarct size. Tracer activities were quantified by gamma well counting and by serial imaging. In protocol 1 dogs with sustained low flow (50% +/- 4%) and absence of systolic thickening (-3.2% +/- 1%), 123I-IPPA defect magnitude (LAD/left circumflex artery [LCX] count ratios) decreased from 0.65 +/- 0.02 to 0.74 +/- 0.02 at 30 min and to 0.84 +/- 0.03 at 2 h (P < 0.01), indicative of rest redistribution. Final transmural 123I-IPPA LAD/LCX activity ratio (0.99 +/- 0.05) was significantly greater than the flow ratio (0.53 +/- 0.04) at injection, confirming complete rest redistribution. The final 123I-IPPA activity ratio was significantly greater than the 201TI ratio over the 2-h period (P < 0.01). In protocol 2 dogs that underwent 3 h of total LAD occlusion and reflow (infarct size = 51% +/- 13% of risk area), viability was overestimated with 123I-IPPA, because uptake averaged 64% of normal in the central necrotic region, where flow averaged < 10% of normal. These findings suggest that serial 123I-IPPA imaging may be useful for assessing myocardial viability under conditions of sustained low flow and myocardial asynergy, such as appears to exist in patients with chronic coronary artery disease and depressed left ventricular function. In contrast, 123I-IPPA given early after reperfusion following prolonged coronary occlusion overestimates the degree of viability and therefore may not provide useful information pertaining to the degree of myocardial salvage after reflow in the setting of acute myocardial infarction.
Davies, O; Szladovits, B; Polton, G; Garden, O A; Leo, C; Lara-Garcia, A
2018-06-01
Canine lymphoma is a heterogeneous group of diseases and many previous studies have evaluated the response of a mixed population of lymphoma cases to one specific treatment protocol. The aim of this retrospective study was to describe the outcome and prognostic factors in 42 cases of multicentric centroblastic diffuse large B-cell lymphoma treated with either a COP-type (35%) or CHOP-type (64%) induction chemotherapy. The objective response rate to induction therapy was 94%; entire dogs had a greater rate of complete vs partial remissions than neutered dogs (P = .017). Median progression-free survival for the first remission (PFS1) was 182 days; absence of anaemia at diagnosis (P = .002) and pretreatment neutrophil:lymphocyte ratio (NLR) below 9.44 (P = .015) were independently predictive of longer PFS1. Fifty-eight percent of dogs received rescue protocols with an objective response rate of 81%; 31% of dogs received further rescue protocols (up to a total of 5) and the median number of protocols administered were 2. Median overall survival (OS) was 322 days, the 1-year survival rate was 38% and the 2-year survival rate was 9%. Lymphocyte:monocyte ratio above 1.43 (P = .031), NLR below 11.44 (P = .009), the combination of induction and rescue therapy (P = .030) and the total number of doxorubicin doses used (P = .002) were independently predictive of longer OS. Use of a COP-type protocol induction compared with CHOP did not undermine OS providing doxorubicin was used as rescue therapy. © 2017 John Wiley & Sons Ltd.
Homeopathy for allergic rhinitis: protocol for a systematic review
2014-01-01
Background Allergic rhinitis is a global health problem that is often treated with homeopathy. The objective of this review will be to evaluate the effectiveness of homeopathic treatment of allergic rhinitis. Methods/Design The authors will conduct a systematic review. We will search Medline, CENTRAL, CINAHL, EMBASE, AMED, CAM-Quest, Google Scholar and reference lists of identified studies up to December 2013. The review will include randomized controlled trials that evaluate homeopathic treatment of allergic rhinitis. Studies with participants of all ages, with acute or chronic comorbidities will be included. Patients with immunodeficiency will not be included. The diagnosis will be based on the published guidelines of diagnosis and classification. Studies of all homeopathy modalities (clinical, complex and classical homeopathy, and isopathy) will be included. We will include trials with both active controls (conventional therapy, standard care) and placebo controls. The primary outcomes are: an improvement of global symptoms recorded in validated daily or weekly diaries and any scores from validated visual analogue scales; the total Quality of Life Score (such as the Juniper RQLQ);individual symptoms scores which include any appropriate measures of nasal obstruction, runny nose, sneezing, itching, and eye symptoms; and number of days requiring medication. Secondary outcomes selected will include serum immunoglobin E (IgE) levels, individual ocular symptoms, adverse events, and the use of rescue medication. Treatment effects will be measured by calculating the mean difference and the standardized mean difference with 95% confidence interval (CI) for continuous data. Risk ratio or, if feasible, odds ratio will be calculated with 95% CI for dichotomous data. After assessing clinical and statistical heterogeneity, meta-analysis will be performed, if appropriate. The individual participant will be the unit of analysis. Descriptive information on missing data will be included about participants missing due to drop out, whether there was intention to treat or per protocol analysis and missing statistics. A number of subgroups, homeopathic potency, age groups, and types of allergic rhinitis (seasonal or perennial) will be analyzed. Sensitivity analysis will be performed to explore the impact of risk of bias on overall treatment effect. Systematic review registration PROSPERO CRD42013006741 PMID:24913155
Clark, Andrea J.; Petty, Howard R.
2016-01-01
This protocol describes the methods and steps involved in performing biomarker ratio imaging microscopy (BRIM) using formalin fixed paraffin-embedded (FFPE) samples of human breast tissue. The technique is based on the acquisition of two fluorescence images of the same microscopic field using two biomarkers and immunohistochemical tools. The biomarkers are selected such that one biomarker correlates with breast cancer aggressiveness while the second biomarker anti-correlates with aggressiveness. When the former image is divided by the latter image, a computed ratio image is formed that reflects the aggressiveness of tumor cells while increasing contrast and eliminating path-length and other artifacts from the image. For example, the aggressiveness of epithelial cells may be assessed by computing ratio images of N-cadherin and E-cadherin images or CD44 and CD24 images, which specifically reflect the mesenchymal or stem cell nature of the constituent cells, respectively. This methodology is illustrated for tissue samples of ductal carcinoma in situ (DCIS) and invasive breast cancer. This tool should be useful in tissue studies of experimental cancer as well as the management of cancer patients. PMID:27857940
Grieser, Christian; Denecke, Timm; Steffen, Ingo G; Werner, Scarlett; Kröncke, Thomas; Guckelberger, Olaf; Pape, Ulrich-Frank; Meier, Johannes; Thiel, Regina; Kivelitz, Dietmar; Sturm, Andreas; Hamm, Bernd; Röttgen, Rainer
2012-04-01
To evaluate fat saturated (fs) T2-weighted (w) fast relaxation fast spin echo (FRFSE)-sequences compared to the standard protocol with contrast agent for the evaluation of inflammatory activity in patients with Crohn's Disease (CD). Fourty-eight patients (male, 17; female, 33; mean age, 37 years) with suspicion of inflammatory activity in proven CD who underwent MR enteroclysis (MRE) at 1.5T (GE Healthcare) were retrospectively included. Two blinded radiologists analyzed MRE images for presence and extent of CD lesions and degree of local inflammation for fsT2-w FRFSE and contrast enhanced T1-w images (T2-activity; T1-activity; score, 1-4) in consensus. Furthermore, mural signal intensity (SI) ratios (T2-ratio; T1-ratio) were recorded. Patient based MRE findings were correlated with endoscopic (45 patients), surgical (6 patients), histopathological, and clinical data (CDAI) as a surrogate reference standard. In total, 24 of 48 eligible patients presented with acute inflammatory activity with 123 affected bowel segments. ROC analysis of the total inflammatory score presented an AUC of 0.93 (p<0.001) for T2-activity (T1-activity, AUC 0.63; p=0.019). ROC analysis revealed an AUC of 0.76 (p<0.001) for the T2-ratio (T1-ratio, AUC 0.51; p=0.93). General linear regression model revealed T2-activity (p=0.001) and age (p=0.024) as predictive factors of acute bowel inflammation. T2-w FRFSE-sequences can depict CD lesions and help to assess the inflammation activity, even with improved accuracy as compared to contrast-enhanced T1-w sequences. Copyright © 2011 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Benson, Sarah J; Lennard, Christopher J; Hill, David M; Maynard, Philip; Roux, Claude
2010-01-01
A significant amount of research has been conducted into the use of stable isotopes to assist in determining the origin of various materials. The research conducted in the forensic field shows the potential of isotope ratio mass spectrometry (IRMS) to provide a level of discrimination not achievable utilizing traditional forensic techniques. Despite the research there have been few, if any, publications addressing the validation and measurement uncertainty of the technique for forensic applications. This study, the first in a planned series, presents validation data for the measurement of bulk nitrogen isotope ratios in ammonium nitrate (AN) using the DELTA(plus)XP (Thermo Finnigan) IRMS instrument equipped with a ConFlo III interface and FlashEA 1112 elemental analyzer (EA). Appropriate laboratory standards, analytical methods and correction calculations were developed and evaluated. A validation protocol was developed in line with the guidelines provided by the National Association of Testing Authorities, Australia (NATA). Performance characteristics including: accuracy, precision/repeatability, reproducibility/ruggedness, robustness, linear range, and measurement uncertainty were evaluated for the measurement of nitrogen isotope ratios in AN. AN (99.5%) and ammonium thiocyanate (99.99+%) were determined to be the most suitable laboratory standards and were calibrated against international standards (certified reference materials). All performance characteristics were within an acceptable range when potential uncertainties, including the manufacturer's uncertainty of the technique and standards, were taken into account. The experiments described in this article could be used as a model for validation of other instruments for similar purposes. Later studies in this series will address the more general issue of demonstrating that the IRMS technique is scientifically sound and fit-for-purpose in the forensic explosives analysis field.
Xu, Mei-Mei; Jia, Hong-Yu; Yan, Li-Li; Li, Shan-Shan; Zheng, Yue
2017-01-01
Abstract Background: This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. Methods: We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. Results: Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%–95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%–91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65–28.14) and 0.16 (95% CI, 0.12–0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65–28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12–0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87–18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09–0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. Conclusion: Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS–FNA. PMID:28151856
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Jacobson, David; Metoyer, Jarred
The specific measure described here involves improving the overall efficiency in air-conditioning systems as a whole (compressor, evaporator, condenser, and supply fan). The efficiency rating is expressed as the energy efficiency ratio (EER), seasonal energy efficiency ratio (SEER), and integrated energy efficiency ratio (IEER). The higher the EER, SEER or IEER, the more efficient the unit is.
Stopping-power and mass energy-absorption coefficient ratios for Solid Water.
Ho, A K; Paliwal, B R
1986-01-01
The AAPM Task Group 21 protocol provides tables of ratios of average restricted stopping powers and ratios of mean energy-absorption coefficients for different materials. These values were based on the work of Cunningham and Schulz. We have calculated these quantities for Solid Water (manufactured by RMI), using the same x-ray spectra and method as that used by Cunningham and Schulz. These values should be useful to people who are using Solid Water for high-energy photon calibration.
The use of a photoionization detector to detect harmful volatile chemicals by emergency personnel
Patel, Neil D; Fales, William D; Farrell, Robert N
2009-01-01
Objective The objective of this investigation was to determine if a photoionization detector (PID) could be used to detect the presence of a simulated harmful chemical on simulated casualties of a chemical release. Methods A screening protocol, based on existing radiation screening protocols, was developed for the purposes of the investigation. Three simulated casualties were contaminated with a simulated chemical agent and two groups of emergency responders were involved in the trials. The success–failure ratio of the participants was used to judge the performance of the PID in this application. Results A high success rate was observed when the screening protocol was properly adhered to (97.67%). Conversely, the success rate suffered when participants deviated from the protocol (86.31%). With one exception, all failures were noted to have been the result of a failure to correctly observe the established screening protocol. Conclusions The results of this investigation indicate that the PID may be an effective screening tool for emergency responders. However, additional study is necessary to both confirm the effectiveness of the PID and refine the screening protocol if necessary. PMID:27147829
RNA isolation from loquat and other recalcitrant woody plants with high quality and yield.
Morante-Carriel, Jaime; Sellés-Marchart, Susana; Martínez-Márquez, Ascensión; Martínez-Esteso, María José; Luque, Ignacio; Bru-Martínez, Roque
2014-05-01
RNA isolation is difficult in plants that contain large amounts of polysaccharides and polyphenol compounds. To date, no commercial kit has been developed for the isolation of high-quality RNA from tissues with these characteristics, especially for fruit. The common protocols for RNA isolation are tedious and usually result in poor yields when applied to recalcitrant plant tissues. Here an efficient RNA isolation protocol based on cetyltrimethylammonium bromide (CTAB) and two successive precipitations with 10 M lithium chloride (LiCl) was developed specifically for loquat fruits, but it was proved to work efficiently in other tissues of loquat and woody plants. The RNA isolated by this improved protocol was not only of high purity and integrity (A260/A280 ratios ranged from 1.90 to 2.04 and A260/A230 ratios were>2.0) but also of high yield (up to 720 μg on average [coefficient of variation=21%] total RNA per gram fresh tissue). The protocol was tested on loquat fruit (different stages of development, postharvest, ripening, and bruising), leaf, root, flower, stem, and bud; quince fruit and root; grapevine cells in liquid culture; and rose petals. The RNA obtained with this method is amenable to enzymatic treatments and can be efficiently applied for research on gene characterization, expression, and function. Copyright © 2014 Elsevier Inc. All rights reserved.
Comparison of two progressive treadmill tests in patients with peripheral arterial disease.
Riebe, D; Patterson, R B; Braun, C M
2001-11-01
In a vascular rehabilitation program, 28% of our frail elderly patients are unable to be tested with traditional progressive exercise protocols at program entry due to the high (2.0 miles/h or 3.2 km/h) initial treadmill speeds. The purpose of this investigation was to compare a new progressive treadmill protocol which has a reduced initial speed (1.0 mile/h or 1.6 km/h) to an established protocol performed at 2.0 miles/h (3.2 km/h) to determine the comparability and reproducibility of the new protocol. Eleven patients with arterial claudication performed three symptom-limited exercise tests in random order. Two tests used the new protocol while the remaining trial used the established protocol. Claudication pain was measured using a 5-point scale. Oxygen consumption, heart rate, minute ventilation, respiratory exchange ratio and blood pressure at peak exercise were similar among the three trials. There were strong intraclass correlations for peak oxygen consumption (r = 0.97), onset of claudication (r = 0.96) and maximum walking time (r = 0.98) between the two trials using the new protocol. There was also a significant correlation between the new protocol and the established protocol for peak oxygen consumption (r = 0.90) and maximum walking time (r = 0.89). The new progressive treadmill protocol represents a valid, reliable protocol for patients with arterial claudication. This protocol may be useful for testing patients with a low functional capacity so that clinically appropriate exercise prescriptions can be established and the efficacy of treatments can be determined.
Impact of a lung transplantation donor-management protocol on lung donation and recipient outcomes.
Angel, Luis F; Levine, Deborah J; Restrepo, Marcos I; Johnson, Scott; Sako, Edward; Carpenter, Andrea; Calhoon, John; Cornell, John E; Adams, Sandra G; Chisholm, Gary B; Nespral, Joe; Roberson, Ann; Levine, Stephanie M
2006-09-15
One of the limitations associated with lung transplantation is the lack of available organs. To determine whether a lung donor-management protocol could increase the number of lungs for transplantation without affecting the survival rates of the recipients. We implemented the San Antonio Lung Transplant protocol for managing potential lung donors according to modifications of standard criteria for donor selection and strategies for donor management. We then compared information gathered during a 4-yr period, during which the protocol was used with information gathered during a 4-yr period before protocol implementation. Primary outcome measures were the procurement rate of lungs and the 30-d and 1-yr survival rates of recipients. We reviewed data from 711 potential lung donors. The mean rate of lung procurement was significantly higher (p < 0.0001) during the protocol period (25.5%) than during the pre-protocol period (11.5%), with an estimated risk ratio of 2.2 in favor of the protocol period. More patients received transplants during the protocol period (n = 121) than during the pre-protocol period (n = 53; p < 0.0001). Of 98 actual lung donors during the protocol period, 53 (54%) had initially been considered poor donors; these donors provided 64 (53%) of the 121 lung transplants. The type of donor was not associated with significant differences in recipients' 30-d and 1-yr survival rates or any clinical measures of adequate graft function. The protocol was associated with a significant increase in the number of lung donors and transplant procedures without compromising pulmonary function, length of stay, or survival of the recipients.
Real-Time Noninvasive Assessment of Pancreatic ATP Levels During Cold Preservation
Scott, W.E.; Matsumoto, S.; Tanaka, T.; Avgoustiniatos, E.S.; Graham, M.L.; Williams, P.C.; Tempelman, L.A.; Sutherland, D.E.; Hering, B.J.; Hammer, B.E.; Papas, K.K.
2008-01-01
31P-NMR spectroscopy was utilized to investigate rat and porcine pancreatic ATP:Pi ratios to assess the efficacy of existing protocols for cold preservation (CP) in maintaining organ quality. Following sacrifice, rat pancreata were immediately excised or left enclosed in the body for 15 minutes of warm ischemia (WI). After excision, rat pancreata were stored at 6°C to 8°C using histidine-tryptophan-ketoglutarate solution (HTK) presaturated with air (S1), HTK presaturated with O2 (S2), or the HTK/perfluorodecalin two-layer method (TLM) with both liquids presaturated with O2 (S3). 31P-NMR spectra were sequentially collected at 3, 6, 9, 12, and 24 hours of CP from pancreata stored with each of the three protocols examined. The ATP:Pi ratio for rat pancreata exposed to 15 minutes of WI and stored with S3 increased during the first 9 hours of CP, approaching values observed for organs procured with no WI. A marked reduction in the ATP:Pi ratio was observed beyond 12 hours of CP with S3. After 6 hours of CP, the ATP:Pi ratio was highest for S3, substantially decreased for S2, and below detection for S1. In sharp contrast to the rat model, ATP was barely detectable in porcine pancreata exposed to minimal warm ischemia (<15 minutes) stored with the TLM regardless of CP time. We conclude that 31P-NMR spectroscopy is a powerful tool that can be used to (1) noninvasively evaluate pancreata prior to islet isolation, (2) assess the efficacy of different preservation protocols, (3) precisely define the timing of reversible versus irreversible damage, and (4) assess whether intervention will extend this timing. PMID:18374082
Finite-key analysis for the 1-decoy state QKD protocol
NASA Astrophysics Data System (ADS)
Rusca, Davide; Boaron, Alberto; Grünenfelder, Fadri; Martin, Anthony; Zbinden, Hugo
2018-04-01
It has been shown that in the asymptotic case of infinite-key length, the 2-decoy state Quantum Key Distribution (QKD) protocol outperforms the 1-decoy state protocol. Here, we present a finite-key analysis of the 1-decoy method. Interestingly, we find that for practical block sizes of up to 108 bits, the 1-decoy protocol achieves for almost all experimental settings higher secret key rates than the 2-decoy protocol. Since using only one decoy is also easier to implement, we conclude that it is the best choice for QKD, in most common practical scenarios.
Wadhwa, Leena; Mishra, Mona
2018-01-01
Objective: The objective of the study was (1) “to evaluate the therapeutic efficacy of endometrial scratching in repeated controlled ovarian stimulation (COS) failure cycles.” And (2) “to compare differences in pregnancy outcome by endometrial scratching in early (D2–D4) and late follicular phases (D7–D9) of the same stimulation cycle.” Materials and Methods: Women attending infertility clinic in a tertiary care center and who have two or more repeated COS failure cycles and planned for COS with intrauterine insemination (IUI) were included in the study which is a prospective parallel, interventional, single-blinded, randomized control study, in 1:1 allocation ratio. A total of 165 patients were recruited and randomly allocated into three groups: Group A (n = 55) underwent endometrial scratching on D2–D4 of the same COS cycle, Group B (n = 55) on D7–D9, and Group C (n = 55) no intervention done. All the patients underwent COS according to standard protocol followed by IUI. Results: Clinical pregnancy rate was 12.73% (odds ratio [OR] =0.87 95% confidence interval [CI] =0.288–2.55, P = 1), 16.36% (OR = 1.15; 95% CI = 0.40–3.23, P = 1), and 14.54%, respectively, in Group A, B, and C, respectively (P = 0.86), as per intention to treat analysis. Using Chi-square test, P value between Group A and B was 0.787, between Group A and C was 1.000, and between Group B and C was 1.000. As per protocol analysis, clinical pregnancy rate was 13.46% (OR = 0.83; 95% CI = 0.27–2.5, P = 0.74), 19.57% (OR = 1.3 95%; CI = 0.45–3.73, P = 0.41), and 15.69%. Using Chi-square test, Pvalue between Group A and B was 0.588, between Group A and C was 0.967, and between Group B and C was 0.815. No abortions and multiple pregnancies occurred in either of the groups. Conclusion: The effect found was of good quantum in Group B as per protocol analysis which could be of clinical relevance if larger sample size would have been taken. Endometrial scratching is a cost-effective and easy technique which may improve clinical pregnancy rates in previous COS failure cycles, but more trials are needed to be conducted using larger sample size to achieve the improved and significant outcome. PMID:29681718
Thermogravimetric Analysis of Single-Wall Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Arepalli, Sivram; Nikolaev, Pavel; Gorelik, Olga
2010-01-01
An improved protocol for thermogravimetric analysis (TGA) of samples of single-wall carbon nanotube (SWCNT) material has been developed to increase the degree of consistency among results so that meaningful comparisons can be made among different samples. This improved TGA protocol is suitable for incorporation into the protocol for characterization of carbon nanotube material. In most cases, TGA of carbon nanotube materials is performed in gas mixtures that contain oxygen at various concentrations. The improved protocol is summarized.
Receiver-Based Ad Hoc On Demand Multipath Routing Protocol for Mobile Ad Hoc Networks
Al-Nahari, Abdulaziz; Mohamad, Mohd Murtadha
2016-01-01
Decreasing the route rediscovery time process in reactive routing protocols is challenging in mobile ad hoc networks. Links between nodes are continuously established and broken because of the characteristics of the network. Finding multiple routes to increase the reliability is also important but requires a fast update, especially in high traffic load and high mobility where paths can be broken as well. The sender node keeps re-establishing path discovery to find new paths, which makes for long time delay. In this paper we propose an improved multipath routing protocol, called Receiver-based ad hoc on demand multipath routing protocol (RB-AOMDV), which takes advantage of the reliability of the state of the art ad hoc on demand multipath distance vector (AOMDV) protocol with less re-established discovery time. The receiver node assumes the role of discovering paths when finding data packets that have not been received after a period of time. Simulation results show the delay and delivery ratio performances are improved compared with AOMDV. PMID:27258013
NASA Astrophysics Data System (ADS)
Wang, Xiao-Jun; An, Long-Xi; Yu, Xu-Tao; Zhang, Zai-Chen
2017-10-01
A multilayer quantum secret sharing protocol based on GHZ state is proposed. Alice has the secret carried by quantum state and wants to distribute this secret to multiple agent nodes in the network. In this protocol, the secret is transmitted and shared layer by layer from root Alice to layered agents. The number of agents in each layer is a geometric sequence with a specific common ratio. By sharing GHZ maximally entangled states and making generalized Bell basis measurement, one qubit state can be distributed to multiparty agents and the secret is shared. Only when all agents at the last layer cooperate together, the secret can be recovered. Compared with other protocols based on the entangled state, this protocol adopts layered construction so that secret can be distributed to more agents with fewer particles GHZ state. This quantum secret sharing protocol can be used in wireless network to ensure the security of information delivery.
Receiver-Based Ad Hoc On Demand Multipath Routing Protocol for Mobile Ad Hoc Networks.
Al-Nahari, Abdulaziz; Mohamad, Mohd Murtadha
2016-01-01
Decreasing the route rediscovery time process in reactive routing protocols is challenging in mobile ad hoc networks. Links between nodes are continuously established and broken because of the characteristics of the network. Finding multiple routes to increase the reliability is also important but requires a fast update, especially in high traffic load and high mobility where paths can be broken as well. The sender node keeps re-establishing path discovery to find new paths, which makes for long time delay. In this paper we propose an improved multipath routing protocol, called Receiver-based ad hoc on demand multipath routing protocol (RB-AOMDV), which takes advantage of the reliability of the state of the art ad hoc on demand multipath distance vector (AOMDV) protocol with less re-established discovery time. The receiver node assumes the role of discovering paths when finding data packets that have not been received after a period of time. Simulation results show the delay and delivery ratio performances are improved compared with AOMDV.
Social-aware data dissemination in opportunistic mobile social networks
NASA Astrophysics Data System (ADS)
Yang, Yibo; Zhao, Honglin; Ma, Jinlong; Han, Xiaowei
Opportunistic Mobile Social Networks (OMSNs), formed by mobile users with social relationships and characteristics, enhance spontaneous communication among users that opportunistically encounter each other. Such networks can be exploited to improve the performance of data forwarding. Discovering optimal relay nodes is one of the important issues for efficient data propagation in OMSNs. Although traditional centrality definitions to identify the nodes features in network, they cannot identify effectively the influential nodes for data dissemination in OMSNs. Existing protocols take advantage of spatial contact frequency and social characteristics to enhance transmission performance. However, existing protocols have not fully exploited the benefits of the relations and the effects between geographical information, social features and user interests. In this paper, we first evaluate these three characteristics of users and design a routing protocol called Geo-Social-Interest (GSI) protocol to select optimal relay nodes. We compare the performance of GSI using real INFOCOM06 data sets. The experiment results demonstrate that GSI overperforms the other protocols with highest data delivery ratio and low communication overhead.
Association between heart rhythm and cortical sound processing.
Marcomini, Renata S; Frizzo, Ana Claúdia F; de Góes, Viviane B; Regaçone, Simone F; Garner, David M; Raimundo, Rodrigo D; Oliveira, Fernando R; Valenti, Vitor E
2018-04-26
Sound signal processing signifies an important factor for human conscious communication and it may be assessed through cortical auditory evoked potentials (CAEP). Heart rate variability (HRV) provides information about heart rate autonomic regulation. We investigated the association between resting HRV and CAEP. We evaluated resting HRV in the time and frequency domain and the CAEP components. The subjects remained at rest for 10 minutes for HRV recording, then they performed the CAEP examinations through frequency and duration protocols in both ears. Linear regression indicated that the amplitude of the N2 wave of the CAEP in the left ear (not right ear) was significantly influenced by standard deviation of normal-to-normal RR-intervals (17.7%) and percentage of adjacent RR-intervals with a difference of duration greater than 50 milliseconds (25.3%) time domain HRV indices in the frequency protocol. In the duration protocol and in the left ear the latency of the P2 wave was significantly influenced by low (LF) (20.8%) and high frequency (HF) bands in normalized units (21%) and LF/HF ratio (22.4%) indices of HRV spectral analysis. The latency of the N2 wave was significantly influenced by LF (25.8%), HF (25.9%) and LF/HF (28.8%). In conclusion, we promote the supposition that resting heart rhythm is associated with thalamo-cortical, cortical-cortical and auditory cortex pathways involved with auditory processing in the right hemisphere.
Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices.
Brower, Kara; White, Adam K; Fordyce, Polly M
2017-01-27
Microfluidic systems have enabled powerful new approaches to high-throughput biochemical and biological analysis. However, there remains a barrier to entry for non-specialists who would benefit greatly from the ability to develop their own microfluidic devices to address research questions. Particularly lacking has been the open dissemination of protocols related to photolithography, a key step in the development of a replica mold for the manufacture of polydimethylsiloxane (PDMS) devices. While the fabrication of single height silicon masters has been explored extensively in literature, fabrication steps for more complicated photolithography features necessary for many interesting device functionalities (such as feature rounding to make valve structures, multi-height single-mold patterning, or high aspect ratio definition) are often not explicitly outlined. Here, we provide a complete protocol for making multilayer microfluidic devices with valves and complex multi-height geometries, tunable for any application. These fabrication procedures are presented in the context of a microfluidic hydrogel bead synthesizer and demonstrate the production of droplets containing polyethylene glycol (PEG diacrylate) and a photoinitiator that can be polymerized into solid beads. This protocol and accompanying discussion provide a foundation of design principles and fabrication methods that enables development of a wide variety of microfluidic devices. The details included here should allow non-specialists to design and fabricate novel devices, thereby bringing a host of recently developed technologies to their most exciting applications in biological laboratories.
Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction
Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko
2015-01-01
Introduction: Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. Subjects and methods: In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student’s T test was used. Results: There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Conclusion: Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction. PMID:25870471
NASA Astrophysics Data System (ADS)
Lye, J. E.; Butler, D. J.; Oliver, C. P.; Alves, A.; Lehmann, J.; Gibbons, F. P.; Williams, I. M.
2016-07-01
Dosimetry protocols for external beam radiotherapy currently in use, such as the IAEA TRS-398 and AAPM TG-51, were written for conventional linear accelerators. In these accelerators, a flattening filter is used to produce a beam which is uniform at water depths where the ionization chamber is used to measure the absorbed dose. Recently, clinical linacs have been implemented without the flattening filter, and published theoretical analysis suggested that with these beams a dosimetric error of order 0.6% could be expected for IAEA TRS-398, because the TPR20,10 beam quality index does not accurately predict the stopping power ratio (water to air) for the softer flattening-filter-free (FFF) beam spectra. We measured doses on eleven FFF linacs at 6 MV and 10 MV using both dosimetry protocols and found average differences of 0.2% or less. The expected shift due to stopping powers was not observed. We present Monte Carlo k Q calculations which show a much smaller difference between FFF and flattened beams than originally predicted. These results are explained by the inclusion of the added backscatter plates and build-up filters used in modern clinical FFF linacs, compared to a Monte Carlo model of an FFF linac in which the flattening filter is removed and no additional build-up or backscatter plate is added.
Parel, I; Cutti, A G; Kraszewski, A; Verni, G; Hillstrom, H; Kontaxis, A
2014-03-01
Multi-center clinical trials incorporating shoulder kinematics are currently uncommon. The absence of repeatability and limits of agreement (LoA) studies between different centers employing different motion analysis protocols has led to a lack dataset compatibility. Therefore, the aim of this work was to determine the repeatability and LoA between two shoulder kinematic protocols. The first one uses a scapula tracker (ST), the International Society of Biomechanics anatomical frames and an optoelectronic measurement system, and the second uses a spine tracker, the INAIL Shoulder and Elbow Outpatient protocol (ISEO) and an inertial and magnetic measurement system. First within-protocol repeatability for each approach was assessed on a group of 23 healthy subjects and compared with the literature. Then, the between-protocol agreement was evaluated. The within-protocol repeatability was similar for the ST ([Formula: see text] = 2.35°, [Formula: see text] = 0.97°, SEM = 2.5°) and ISEO ([Formula: see text] = 2.24°, [Formula: see text] = 0.97°, SEM = 2.3°) protocols and comparable with data from published literature. The between-protocol agreement analysis showed comparable scapula medio-lateral rotation measurements for up to 120° of flexion-extension and up to 100° of scapula plane ab-adduction. Scapula protraction-retraction measurements were in agreement for a smaller range of humeral elevation. The results of this study suggest comparable repeatability for the ST and ISEO protocols and between-protocol agreement for two scapula rotations. Different thresholds for repeatability and LoA may be adapted to suit different clinical hypotheses.
Changing the Management of Paracetamol Poisoning.
Bateman, D Nicholas
2015-09-01
The management of paracetamol poisoning was revolutionized after use of acetylcysteine in the 1970s. The protocol used, 3 weight-related infusions, requires almost 24 hours in hospital. It is associated with adverse events in treated patients, particularly anaphylactoid reactions and vomiting. Present treatment nomograms were based on a small series of untreated patients: only 5 of 22 (23%) and 6 of 25 (24%) between the 100 to 200 mg/L and 200 to 300 mg/L nomogram lines, respectively, developed liver injury (alanine transaminase >1000 IU/L). Many patients treated today are unlikely to be at actual risk for major hepatotoxicity. This article discusses the background to future prospects in this area. The history behind approaches to the use of acetylcysteine is presented briefly. The rationale for, and key findings of, a new 12-hour antidote regimen for paracetamol poisoning are detailed. Newer markers of hepatotoxicity, such as miR-122, HMGB1, and necrosis K18, which predict patients at risk more reliably and earlier than existing tests, are discussed. A 2-phase 12-hour acetylcysteine infusion protocol (100 mg/kg over 2 hours: 200 mg/kg over 10 hours) was studied in a formal factorial design against the traditional 3-phase 20.25-hour infusion protocol, with and without pretreatment with ondansetron or placebo. The 12-hour regimen was associated with very significant reductions in anaphylactoid reactions (odds ratio = 0.23; 95% CI, 0.12-0.43; P < 0.0001) and vomiting (odds ratio = 0.37; 95% CI, 0.18-0.79; P = .003) compared with the 20.25-hour infusion protocol. There were few withdrawals from the clinical trial, indicating the feasibility of conducting such studies in Europe. Novel proteomic markers are better than existing standard tests (alanine transaminase and international normalized ratio) early in the course of paracetamol poisoning. Together with these new biomarkers of hepatotoxicity, a 12-hour acetylcysteine protocol offers clinicians and patients the possibility for better targeting of therapy, fewer adverse effects, a simpler dosing regimen, and shorter hospital stay. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.
Pérula-de-Torres, Luis Á; Martínez-Adell, Miguel Á; González-Blanco, Virginia; Baena-Díez, José M; Martín-Rioboó, Enrique; Parras-Rejano, Juan M; González-Lama, Jesús; Martín-Alvarez, Remedios; Ruiz-Moral, Roger; Fernández-García, José Á; Pérez-Díaz, Modesto; Ruiz-de-Castroviejo, Joaquin; Pérula-de-Torres, Carlos; Valero-Martín, Antonio; Roldán-Villalobos, Ana; Criado-Larumbe, Margarita; Burdoy-Joaquín, Emili; Coma-Solé, Montserrat; Cervera-León, Mercè; Cuixart-Costa, Lluís
2012-10-30
Clinical Practice Guidelines recommend using peripheral blood pulse measuring as a screening test for Atrial Fibrillation. However, there is no adequate evidence supporting the efficacy of such procedure in primary care clinical practice. This paper describes a study protocol designed to verify whether early opportunistic screening for Atrial Fibrillation by measuring blood pulse is more effective than regular practice in subjects aged 65 years attending primary care centers. An cluster-randomized controlled trial conducted in Primary Care Centers of the Spanish National Health Service. A total of 269 physicians and nurses will be allocated to one of the two arms of the trial by stratified randomization with a 3:2 ratio (three practitioners will be assigned to the Control Group for every two practitioners assigned to the Experimental Group). As many as 12 870 patients aged 65 years or older and meeting eligibility criteria will be recruited (8 580 will be allocated to the Experimental Group and 4 290 to the Control Group). Randomization and allocation to trial groups will be carried out by a central computer system. The Experimental Group practitioners will conduct an opportunistic case finding for patients with Atrial Fibrillation, while the Control Group practitioners will follow the regular guidelines. The first step will be finding new Atrial Fibrillation cases. A descriptive inferential analysis will be performed (bivariate and multivariate by multilevel logistic regression analysis). If our hypothesis is confirmed, we expect Primary Care professionals to take a more proactive approach and adopt a new protocol when a patient meeting the established screening criteria is identified. Finally, we expect this measure to be incorporated into Clinical Practice Guidelines. The study is registered as NCT01291953 (ClinicalTrials.gob).
Chang, Ke-Vin; Hung, Chen-Yu; Han, Der-Sheng; Chen, Wen-Shiang; Wang, Tyng-Guey; Chien, Kuo-Liong
2015-05-01
Postoperative shoulder stiffness complicates functional recovery after arthroscopic rotator cuff repair. To compare early passive range of motion (ROM) exercise with a delayed rehabilitation protocol with regard to the effectiveness of stiffness reduction and functional improvements and rates of improper healing in patients undergoing arthroscopic repair for torn rotator cuffs. Systematic review and meta-analysis. Randomized controlled trials (RCTs) comparing both rehabilitation approaches were identified in PubMed and Scopus. Between-group differences in shoulder function were transformed to effect sizes for comparisons, whereas the effectiveness against stiffness and the risk of tendon failure were reported using standardized mean differences of ROM degrees and odds ratios (ORs) of recurrent tears, respectively. Six RCTs were included, consisting of 482 patients. No significant difference in shoulder function existed across both protocols. The early ROM group demonstrated more improvement in shoulder forward flexion than the delayed rehabilitation group, with a standardized mean difference of 7.45° (95% CI, 3.20°-11.70°) at 6 months and 3.51° (95% CI, 0.31°-6.71°) at 12 months. Early ROM exercise tended to cause a higher rate of recurrent tendon tears (OR, 1.43; 95% CI, 0.90-2.28), and the effect became statistically significant (OR, 1.93; 95% CI, 1.04-3.60) after excluding 2 RCTs that recruited only those patients with small to medium-sized tears. Early ROM exercise accelerated recovery from postoperative stiffness for patients after arthroscopic rotator cuff repair but was likely to result in improper tendon healing in shoulders with large-sized tears. The choice of either protocol should be based on an accommodation of the risks of recurrent tears and postoperative shoulder stiffness. © 2014 The Author(s).
Jeziorowska, Dorota; Fontaine, Vincent; Jouve, Charlène; Villard, Eric; Dussaud, Sébastien; Akbar, David; Letang, Valérie; Cervello, Pauline; Itier, Jean-Michiel; Pruniaux, Marie-Pierre; Hulot, Jean-Sébastien
2017-01-01
Human induced pluripotent stem cells (iPSCs) represent a powerful human model to study cardiac disease in vitro, notably channelopathies and sarcomeric cardiomyopathies. Different protocols for cardiac differentiation of iPSCs have been proposed either based on embroid body formation (3D) or, more recently, on monolayer culture (2D). We performed a direct comparison of the characteristics of the derived cardiomyocytes (iPSC-CMs) on day 27 ± 2 of differentiation between 3D and 2D differentiation protocols with two different Wnt-inhibitors were compared: IWR1 (inhibitor of Wnt response) or IWP2 (inhibitor of Wnt production). We firstly found that the level of Troponin T (TNNT2) expression measured by FACS was significantly higher for both 2D protocols as compared to the 3D protocol. In the three methods, iPSC-CM show sarcomeric structures. However, iPSC-CM generated in 2D protocols constantly displayed larger sarcomere lengths as compared to the 3D protocol. In addition, mRNA and protein analyses reveal higher cTNi to ssTNi ratios in the 2D protocol using IWP2 as compared to both other protocols, indicating a higher sarcomeric maturation. Differentiation of cardiac myocytes with 2D monolayer-based protocols and the use of IWP2 allows the production of higher yield of cardiac myocytes that have more suitable characteristics to study sarcomeric cardiomyopathies. PMID:28587156
APOE Genotyping, Cardiovascular Disease
... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... tests are most often done as part of research protocols to help understand the role of genetic ...
Tumor Content Chart-Assisted HER2/CEP17 Digital PCR Analysis of Gastric Cancer Biopsy Specimens.
Matsusaka, Keisuke; Ishikawa, Shumpei; Nakayama, Atsuhito; Ushiku, Tetsuo; Nishimoto, Aiko; Urabe, Masayuki; Kaneko, Nobuyuki; Kunita, Akiko; Kaneda, Atsushi; Aburatani, Hiroyuki; Fujishiro, Mitsuhiro; Seto, Yasuyuki; Fukayama, Masashi
2016-01-01
Evaluating HER2 gene amplification is an essential component of therapeutic decision-making for advanced or metastatic gastric cancer. A simple method that is applicable to small, formalin-fixed, paraffin-embedded biopsy specimens is desirable as an adjunct to or as a substitute for currently used HER2 immunohistochemistry and in situ hybridization protocols. In this study, we developed a microfluidics-based digital PCR method for determining HER2 and chromosome 17 centromere (CEP17) copy numbers and estimating tumor content ratio (TCR). The HER2/CEP17 ratio is determined by three variables-TCR and absolute copy numbers of HER2 and CEP17-by examining tumor cells; only the ratio of the latter two can be obtained by digital PCR using the whole specimen without purifying tumor cells. TCR was determined by semi-automatic image analysis. We developed a Tumor Content chart, which is a plane of rectangular coordinates consisting of HER2/CEP17 digital PCR data and TCR that delineates amplified, non-amplified, and equivocal areas. By applying this method, 44 clinical gastric cancer biopsy samples were classified as amplified (n = 13), non-amplified (n = 25), or equivocal (n = 6). By comparison, 11 samples were positive, 11 were negative, and 22 were equivocally immunohistochemistry. Thus, our novel method reduced the number of equivocal samples from 22 to 6, thereby obviating the need for confirmation by fluorescence or dual-probe in situ hybridization to < 30% of cases. Tumor content chart-assisted digital PCR analysis is also applicable to multiple sites in surgically resected tissues. These results indicate that this analysis is a useful alternative to HER2 immunohistochemistry in gastric cancers that can serve as a basis for the automated evaluation of HER2 status.
Tumor Content Chart-Assisted HER2/CEP17 Digital PCR Analysis of Gastric Cancer Biopsy Specimens
Matsusaka, Keisuke; Ishikawa, Shumpei; Nakayama, Atsuhito; Ushiku, Tetsuo; Nishimoto, Aiko; Urabe, Masayuki; Kaneko, Nobuyuki; Kunita, Akiko; Kaneda, Atsushi; Aburatani, Hiroyuki; Fujishiro, Mitsuhiro; Seto, Yasuyuki; Fukayama, Masashi
2016-01-01
Evaluating HER2 gene amplification is an essential component of therapeutic decision-making for advanced or metastatic gastric cancer. A simple method that is applicable to small, formalin-fixed, paraffin-embedded biopsy specimens is desirable as an adjunct to or as a substitute for currently used HER2 immunohistochemistry and in situ hybridization protocols. In this study, we developed a microfluidics-based digital PCR method for determining HER2 and chromosome 17 centromere (CEP17) copy numbers and estimating tumor content ratio (TCR). The HER2/CEP17 ratio is determined by three variables—TCR and absolute copy numbers of HER2 and CEP17—by examining tumor cells; only the ratio of the latter two can be obtained by digital PCR using the whole specimen without purifying tumor cells. TCR was determined by semi-automatic image analysis. We developed a Tumor Content chart, which is a plane of rectangular coordinates consisting of HER2/CEP17 digital PCR data and TCR that delineates amplified, non-amplified, and equivocal areas. By applying this method, 44 clinical gastric cancer biopsy samples were classified as amplified (n = 13), non-amplified (n = 25), or equivocal (n = 6). By comparison, 11 samples were positive, 11 were negative, and 22 were equivocally immunohistochemistry. Thus, our novel method reduced the number of equivocal samples from 22 to 6, thereby obviating the need for confirmation by fluorescence or dual-probe in situ hybridization to < 30% of cases. Tumor content chart-assisted digital PCR analysis is also applicable to multiple sites in surgically resected tissues. These results indicate that this analysis is a useful alternative to HER2 immunohistochemistry in gastric cancers that can serve as a basis for the automated evaluation of HER2 status. PMID:27119558
Cost effectiveness of a protocol using palivizumab in preterm infants.
Hernández-Gago, Yolanda; Lombardero-Pin, Marina; Ortega de la Cruz, Casilda; Maciuniak, Pablo A; Díez Del Pino, Alicia
2017-03-01
The main objective was to evaluate the cost-effectiveness of protocol use of palivizumab in premature established by consensus in our Hospital comparing it based on the recommendations of various Scientific Societies. As a secondary objective risk factors and severity of hospitalized patients attending the established protocol in our Hospital were analyzed. The study period was 4 seasons with the expanded protocol (retrospective data) versus 2 with restricted or agreed protocol (prospective data). The perspective of the study was the Health System, including the costs of hospitalization and palivizumab our center. The calculation of the effectiveness was determined with the admission rate of premature patients stratified by weeks of gestational age <29, <32; and <35. For the analysis of risk factors and severity in patients admitted seasons with the new protocol are collected prospectively clinical data and environmental and social factors. In the range of gestational age <29 years old and <32 greater effectiveness of the extended protocol was not demonstrated against the consensus. Only more effective for EG <35 in the accumulated data and comparing seasons 12/13 and 08/09 to 13/14 for individual data was observed. This range has an associated incremental cost effectiveness ratio of € 53 250,07 (range: € 14 793,39 to € 90 446,47 for singles data and € 50 525,53 (€ 28 688.22 to € 211 575,65) for accumulated. The establishment of this protocol in our center meant an average saving per season € 169 911,51. A cost-effectiveness of the extended protocol appropriate relationship is found if the cost of palivizumab per patient was less than € 1 206,67 (calculated for maximum use of the vial) and a higher rate of hospitalization of 9.21%. Children entering the season with the new protocol (season 12/13 and 13/14) are 63.4% in children under 3 months and 90% are term infants who do not belong to any population at risk, while many of them have associated risk factors you vary as have school-age siblings, rural residence, parental smoking, poor educational background of parents, lack of artificial feeding and family history of allergy. The consensus protocol has not been a significant increase in hospitalization rates in preterm infants <32 weeks gestational age patients. In those <35 has been observed a higher rate of hospitalization, with a very unfavorable cost-effectiveness for all clinical scenarios valued relationship. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Qu, Shu-Gen; Gao, Jin; Tang, Bo; Yu, Bo; Shen, Yue-Ping; Tu, Yu
2018-05-01
Low-dose ionizing radiation (LDIR) may increase the mortality of solid cancers in nuclear industry workers, but only few individual cohort studies exist, and the available reports have low statistical power. The aim of the present study was to focus on solid cancer mortality risk from LDIR in the nuclear industry using standard mortality ratios (SMRs) and 95% confidence intervals. A systematic literature search through the PubMed and Embase databases identified 27 studies relevant to this meta-analysis. There was statistical significance for total, solid and lung cancers, with meta-SMR values of 0.88, 0.80, and 0.89, respectively. There was evidence of stochastic effects by IR, but more definitive conclusions require additional analyses using standardized protocols to determine whether LDIR increases the risk of solid cancer-related mortality.
Kasenda, Benjamin; Schandelmaier, Stefan; Sun, Xin; von Elm, Erik; You, John; Blümle, Anette; Tomonaga, Yuki; Saccilotto, Ramon; Amstutz, Alain; Bengough, Theresa; Meerpohl, Joerg J; Stegert, Mihaela; Olu, Kelechi K; Tikkinen, Kari A O; Neumann, Ignacio; Carrasco-Labra, Alonso; Faulhaber, Markus; Mulla, Sohail M; Mertz, Dominik; Akl, Elie A; Bassler, Dirk; Busse, Jason W; Ferreira-González, Ignacio; Lamontagne, Francois; Nordmann, Alain; Gloy, Viktoria; Raatz, Heike; Moja, Lorenzo; Rosenthal, Rachel; Ebrahim, Shanil; Vandvik, Per O; Johnston, Bradley C; Walter, Martin A; Burnand, Bernard; Schwenkglenks, Matthias; Hemkens, Lars G; Bucher, Heiner C; Guyatt, Gordon H; Briel, Matthias
2014-07-16
To investigate the planning of subgroup analyses in protocols of randomised controlled trials and the agreement with corresponding full journal publications. Cohort of protocols of randomised controlled trial and subsequent full journal publications. Six research ethics committees in Switzerland, Germany, and Canada. 894 protocols of randomised controlled trial involving patients approved by participating research ethics committees between 2000 and 2003 and 515 subsequent full journal publications. Of 894 protocols of randomised controlled trials, 252 (28.2%) included one or more planned subgroup analyses. Of those, 17 (6.7%) provided a clear hypothesis for at least one subgroup analysis, 10 (4.0%) anticipated the direction of a subgroup effect, and 87 (34.5%) planned a statistical test for interaction. Industry sponsored trials more often planned subgroup analyses compared with investigator sponsored trials (195/551 (35.4%) v 57/343 (16.6%), P<0.001). Of 515 identified journal publications, 246 (47.8%) reported at least one subgroup analysis. In 81 (32.9%) of the 246 publications reporting subgroup analyses, authors stated that subgroup analyses were prespecified, but this was not supported by 28 (34.6%) corresponding protocols. In 86 publications, authors claimed a subgroup effect, but only 36 (41.9%) corresponding protocols reported a planned subgroup analysis. Subgroup analyses are insufficiently described in the protocols of randomised controlled trials submitted to research ethics committees, and investigators rarely specify the anticipated direction of subgroup effects. More than one third of statements in publications of randomised controlled trials about subgroup prespecification had no documentation in the corresponding protocols. Definitive judgments regarding credibility of claimed subgroup effects are not possible without access to protocols and analysis plans of randomised controlled trials. © The DISCO study group 2014.
Bjerneld, Erik J; Johansson, Johan D; Laurin, Ylva; Hagner-McWhirter, Åsa; Rönn, Ola; Karlsson, Robert
2015-09-01
A pre-labeling protocol based on Cy5 N-hydroxysuccinimide (NHS) ester labeling of proteins has been developed for one-dimensional sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analysis. We show that a fixed amount of sulfonated Cy5 can be used in the labeling reaction to label proteins over a broad concentration range-more than three orders of magnitude. The optimal amount of Cy5 was found to be 50 to 250pmol in 20μl using a Tris-HCl labeling buffer at pH 8.7. Labeling protein samples with a fixed amount of dye in this range balances the requirements of sub-nanogram detection sensitivity and low dye-to-protein (D/P) ratios for SDS-PAGE. Simulations of the labeling reaction reproduced experimental observations of both labeling kinetics and D/P ratios. Two-dimensional electrophoresis was used to examine the labeling of proteins in a cell lysate using both sulfonated and non-sulfonated Cy5. For both types of Cy5, we observed efficient labeling across a broad range of molecular weights and isoelectric points. Copyright © 2015 Elsevier Inc. All rights reserved.
Quantifying learning in biotracer studies.
Brown, Christopher J; Brett, Michael T; Adame, Maria Fernanda; Stewart-Koster, Ben; Bunn, Stuart E
2018-04-12
Mixing models have become requisite tools for analyzing biotracer data, most commonly stable isotope ratios, to infer dietary contributions of multiple sources to a consumer. However, Bayesian mixing models will always return a result that defaults to their priors if the data poorly resolve the source contributions, and thus, their interpretation requires caution. We describe an application of information theory to quantify how much has been learned about a consumer's diet from new biotracer data. We apply the approach to two example data sets. We find that variation in the isotope ratios of sources limits the precision of estimates for the consumer's diet, even with a large number of consumer samples. Thus, the approach which we describe is a type of power analysis that uses a priori simulations to find an optimal sample size. Biotracer data are fundamentally limited in their ability to discriminate consumer diets. We suggest that other types of data, such as gut content analysis, must be used as prior information in model fitting, to improve model learning about the consumer's diet. Information theory may also be used to identify optimal sampling protocols in situations where sampling of consumers is limited due to expense or ethical concerns.
NASA Astrophysics Data System (ADS)
Preciado, C., Jr.
2016-12-01
Compound-specific stable isotope analysis (CSIA) has become a powerful tool for reconstructing consumer-resource relationships in modern and ancient systems. Stable nitrogen isotope analysis (δ15N) of "trophic" and "source" amino acids provides independent proxies of trophic position and the δ15N value at the base of the food web, respectively. When applied to avian egg tissues (e.g., shell protein, membrane), which can be preserved in the archaeological record, this approach can be used to address complex questions in food web architecture and biogeochemical cycling. In this study, we examined how sample-processing protocols affected the chromatography and reliability of δ15N values of individual amino acids in avian (chicken and penguin) egg components (shell protein, membrane, yolk, and albumen) via gas chromatography-combustion-isotope ratio mass spectrometry. "Unprocessed" egg tissues underwent standard acid hydrolysis protocols prior to derivatization, and resulted in poor chromatography with highly variable δ15N values across replicates. "Processed" samples were eluted through cation exchange columns (Dowex 50WX*400) prior to derivatization, followed by a P-buffer (KH2PO4 + Na2HPO4)-chloroform centrifugation extraction to remove confounding peaks and matrix impurities. These additional procedures greatly improved the chromatography of the "processed" samples, revealing better peak separation and baseline integration as well as lower δ15N variability. Additionally, a standard lipid extraction was necessary for yolk but not membrane, albumen, and shell. While the additional procedures applied to the "columned" samples did result in a significant reduction in sample yield ( 20%), it was non-fractionating and thus only affected the total sample sizes necessary for δ15N CSIA (shell protein 50mg and membrane, yolk, and albumen 0.5mg). The protocols developed here will streamline CSIA of egg tissues for future work in avian ecology.
Abuodeh, Yazan; Naghavi, Arash O; Echevarria, Michelle; DeMarco, MaryLou; Tonner, Brian; Feygelman, Vladimir; Stevens, Craig W; Perez, Bradford A; Dilling, Thomas J
2018-01-01
A previous meta-analysis (MA) found postoperative radiotherapy (PORT) in lung cancer patients to be detrimental in N0/N1 patients and equivocal in the N2 setting. We hypothesized that treatment plans generated using MA protocols had worse dosimetric outcomes compared to modern plans. We retrieved plans for 13 patients who received PORT with modern planning. A plan was recreated for each patient using the 8 protocols included in MA. Dosimetric values were then compared between the modern and simulated MA plans. A total of 104 MA plans were generated. Median prescribed dose was 50.4 (range, 50-60) Gy in the modern plans and 53.2 (30-60) Gy in the MA protocols. Median planning volume coverage was 96% (93%-100%) in the modern plans, versus 58% (0%-100%) in the MA plans (P < .001). Internal target volume coverage was 100% (99%-100%) versus 65% (0%-100%), respectively (P < .001). Organs at risk received the following doses: spinal cord maximum dose, 36.8 (4.6-50.4) Gy versus 46.8 (2.9-74.0) Gy (P < .001); esophageal mean dose, 22.9 (5.5-35) Gy versus 30.5 (11.1-52.5) Gy (P = .003); heart V30 (percentage of volume of an organ receiving at least a dose of 30 Gy), 16% (0%-45%) versus 35% (0%-79%) (P = .047); mean lung dose, 12.4 (3.4-24.3) Gy versus 14.8 (4.1-27.4) Gy (P = .008); and lung V20, 18% (4%-34%) versus 25% (8%-67%) (P = .023). We quantitatively confirm the inferiority of the techniques used in the PORT MA. Our analysis showed a lower therapeutic ratio in the MA plans, which may explain the poor outcomes in the MA. The findings of the MA are not relevant in the era of modern treatment planning. Copyright © 2017 Elsevier Inc. All rights reserved.
Quantification of the thorax-to-abdomen breathing ratio for breathing motion modeling.
White, Benjamin M; Zhao, Tianyu; Lamb, James; Bradley, Jeffrey D; Low, Daniel A
2013-06-01
The purpose of this study was to develop a methodology to quantitatively measure the thorax-to-abdomen breathing ratio from a 4DCT dataset for breathing motion modeling and breathing motion studies. The thorax-to-abdomen breathing ratio was quantified by measuring the rate of cross-sectional volume increase throughout the thorax and abdomen as a function of tidal volume. Twenty-six 16-slice 4DCT patient datasets were acquired during quiet respiration using a protocol that acquired 25 ciné scans at each couch position. Fifteen datasets included data from the neck through the pelvis. Tidal volume, measured using a spirometer and abdominal pneumatic bellows, was used as breathing-cycle surrogates. The cross-sectional volume encompassed by the skin contour when compared for each CT slice against the tidal volume exhibited a nearly linear relationship. A robust iteratively reweighted least squares regression analysis was used to determine η(i), defined as the amount of cross-sectional volume expansion at each slice i per unit tidal volume. The sum Ση(i) throughout all slices was predicted to be the ratio of the geometric expansion of the lung and the tidal volume; 1.11. The Xiphoid process was selected as the boundary between the thorax and abdomen. The Xiphoid process slice was identified in a scan acquired at mid-inhalation. The imaging protocol had not originally been designed for purposes of measuring the thorax-to-abdomen breathing ratio so the scans did not extend to the anatomy with η(i) = 0. Extrapolation of η(i)-η(i) = 0 was used to include the entire breathing volume. The thorax and abdomen regions were individually analyzed to determine the thorax-to-abdomen breathing ratios. There were 11 image datasets that had been scanned only through the thorax. For these cases, the abdomen breathing component was equal to 1.11 - Ση(i) where the sum was taken throughout the thorax. The average Ση(i) for thorax and abdomen image datasets was found to be 1.20 ± 0.17, close to the expected value of 1.11. The thorax-to-abdomen breathing ratio was 0.32 ± 0.24. The average Ση(i) was 0.26 ± 0.14 in the thorax and 0.93 ± 0.22 in the abdomen. In the scan datasets that encompassed only the thorax, the average Ση(i) was 0.21 ± 0.11. A method to quantify the relationship between abdomen and thoracic breathing was developed and characterized.
Bakhru, Rita N; McWilliams, David J; Wiebe, Douglas J; Spuhler, Vicki J; Schweickert, William D
2016-09-01
Early mobilization (EM) improves outcomes for mechanically ventilated patients. Variation in structure and organizational characteristics may affect implementation of EM practices. We queried intensive care unit (ICU) environment and standardized ICU practices to evaluate organizational characteristics that enable EM practice. We recruited 151 ICUs in France, 150 in Germany, 150 in the United Kingdom, and 500 in the United States by telephone. Survey domains included respondent characteristics, hospital and ICU characteristics, and ICU practices and protocols. We surveyed 1,484 ICU leaders and received a 64% response rate (951 ICUs). Eighty-eight percent of respondents were in nursing leadership roles; the remainder were physiotherapists. Surveyed ICUs were predominantly mixed medical-surgical units (67%), and 27% were medical ICUs. ICU staffing models differed significantly (P < 0.001 each) by country for high-intensity staffing, nurse/patient ratios, and dedicated physiotherapists. ICU practices differed by country, with EM practices present in 40% of French ICUs, 59% of German ICUs, 52% of U.K. ICUs, and 45% of U.S. ICUs. Formal written EM protocols were present in 24%, 30%, 20%, and 30%, respectively, of those countries' ICUs. In multivariate analysis, EM practice was associated with multidisciplinary rounds (odds ratio [OR], 1.77; P = 0.001), setting daily goals for patients (OR, 1.62; P = 0.02), presence of a dedicated physiotherapist (OR, 2.48; P < 0.001), and the ICU's being located in Germany (reference, United States; OR, 2.84; P < 0.001). EM practice was also associated with higher nurse staffing levels (1:1 nurse/patient ratio as a reference; 1:2 nurse/patient ratio OR, 0.59; P = 0.05; 1:3 nurse/patient ratio OR, 0.33; P = 0.005; 1:4 or less nurse/patient ratio OR, 0.37; P = 0.005). Those responding rarely cited ambulation of mechanically ventilated patients, use of a bedside cycle, or neuromuscular electrical stimulation as part of their EM practice. Physical therapy initiation, barriers to EM practice, and EM equipment were highly variable among respondents. International ICU structure and practice is quite heterogeneous, and several factors (multidisciplinary rounds, setting daily goals for patients, presence of a dedicated physiotherapist, country, and nurse/patient staffing ratio) are significantly associated with the practice of EM. Practice and barriers may be far different based upon staffing structure. To achieve successful implementation, whether through trials or quality improvement, ICU staffing and practice patterns must be taken into account.
Probability Elicitation Under Severe Time Pressure: A Rank-Based Method.
Jaspersen, Johannes G; Montibeller, Gilberto
2015-07-01
Probability elicitation protocols are used to assess and incorporate subjective probabilities in risk and decision analysis. While most of these protocols use methods that have focused on the precision of the elicited probabilities, the speed of the elicitation process has often been neglected. However, speed is also important, particularly when experts need to examine a large number of events on a recurrent basis. Furthermore, most existing elicitation methods are numerical in nature, but there are various reasons why an expert would refuse to give such precise ratio-scale estimates, even if highly numerate. This may occur, for instance, when there is lack of sufficient hard evidence, when assessing very uncertain events (such as emergent threats), or when dealing with politicized topics (such as terrorism or disease outbreaks). In this article, we adopt an ordinal ranking approach from multicriteria decision analysis to provide a fast and nonnumerical probability elicitation process. Probabilities are subsequently approximated from the ranking by an algorithm based on the principle of maximum entropy, a rule compatible with the ordinal information provided by the expert. The method can elicit probabilities for a wide range of different event types, including new ways of eliciting probabilities for stochastically independent events and low-probability events. We use a Monte Carlo simulation to test the accuracy of the approximated probabilities and try the method in practice, applying it to a real-world risk analysis recently conducted for DEFRA (the U.K. Department for the Environment, Farming and Rural Affairs): the prioritization of animal health threats. © 2015 Society for Risk Analysis.
2015-01-06
Carnegie Mellon University rwcut Default Display By default • sIP , sPort • dIP, dPort • protocol • packets, bytes • flags • sTime, eTime, duration...TCP/IP SOCKET IP address: 10.0.0.1 L4 protocol : TCP High-numbered ephemeral port # TCP/IP SOCKET IP address: 203.0.113.1 L4 protocol : TCP Low-numbered...Fields found to be useful in analysis: • source address, destination address • source port, destination port (Internet Control Message Protocol
NASA Astrophysics Data System (ADS)
Lahiri, B. B.; Ranoo, Surojit; Philip, John
2017-11-01
Magnetic fluid hyperthermia (MFH) is becoming a viable cancer treatment methodology where the alternating magnetic field induced heating of magnetic fluid is utilized for ablating the cancerous cells or making them more susceptible to the conventional treatments. The heating efficiency in MFH is quantified in terms of specific absorption rate (SAR), which is defined as the heating power generated per unit mass. In majority of the experimental studies, SAR is evaluated from the temperature rise curves, obtained under non-adiabatic experimental conditions, which is prone to various thermodynamic uncertainties. A proper understanding of the experimental uncertainties and its remedies is a prerequisite for obtaining accurate and reproducible SAR. Here, we study the thermodynamic uncertainties associated with peripheral heating, delayed heating, heat loss from the sample and spatial variation in the temperature profile within the sample. Using first order approximations, an adiabatic reconstruction protocol for the measured temperature rise curves is developed for SAR estimation, which is found to be in good agreement with those obtained from the computationally intense slope corrected method. Our experimental findings clearly show that the peripheral and delayed heating are due to radiation heat transfer from the heating coils and slower response time of the sensor, respectively. Our results suggest that the peripheral heating is linearly proportional to the sample area to volume ratio and coil temperature. It is also observed that peripheral heating decreases in presence of a non-magnetic insulating shielding. The delayed heating is found to contribute up to ~25% uncertainties in SAR values. As the SAR values are very sensitive to the initial slope determination method, explicit mention of the range of linear regression analysis is appropriate to reproduce the results. The effect of sample volume to area ratio on linear heat loss rate is systematically studied and the results are compared using a lumped system thermal model. The various uncertainties involved in SAR estimation are categorized as material uncertainties, thermodynamic uncertainties and parametric uncertainties. The adiabatic reconstruction is found to decrease the uncertainties in SAR measurement by approximately three times. Additionally, a set of experimental guidelines for accurate SAR estimation using adiabatic reconstruction protocol is also recommended. These results warrant a universal experimental and data analysis protocol for SAR measurements during field induced heating of magnetic fluids under non-adiabatic conditions.
Thomas, C; Patschan, O; Ketelsen, D; Tsiflikas, I; Reimann, A; Brodoefel, H; Buchgeister, M; Nagele, U; Stenzl, A; Claussen, C; Kopp, A; Heuschmid, M; Schlemmer, H-P
2009-06-01
The efficiency and radiation dose of a low-dose dual-energy (DE) CT protocol for the evaluation of urinary calculus disease were evaluated. A low-dose dual-source DE-CT renal calculi protocol (140 kV, 46 mAs; 80 kV, 210 mAs) was derived from the single-energy (SE) CT protocol used in our institution for the detection of renal calculi (120 kV, 75 mAs). An Alderson-Rando phantom was equipped with thermoluminescence dosimeters and examined by CT with both protocols. The effective doses were calculated. Fifty-one patients with suspected or known urinary calculus disease underwent DE-CT. DE analysis was performed if calculi were detected using a dedicated software tool. Results were compared to chemical analysis after invasive calculus extraction. An effective dose of 3.43 mSv (male) and 5.30 mSv (female) was measured in the phantom for the DE protocol (vs. 3.17/4.57 mSv for the SE protocol). Urinary calculi were found in 34 patients; in 28 patients, calculi were removed and analyzed (23 patients with calcified calculi, three with uric acid calculi, one with 2,8-dihyxdroxyadenine-calculi, one patient with a mixed struvite calculus). DE analysis was able to distinguish between calcified and non-calcified calculi in all cases. In conclusion, dual-energy urinary calculus analysis is effective also with a low-dose protocol. The protocol tested in this study reliably identified calcified urinary calculi in vivo.
Tisdale, Evgenia; Wilkins, Charles
2014-04-11
The influence of the sample preparation parameters (the choice of the solvent and of the matrix:analyte ratio) was investigated and optimal conditions were established for MALDI mass spectrometry analysis of the pristine low molecular weight polyvinyl acetate (PVAc). It was demonstrated that comparison of polymer's and solvent's Hansen solubility parameters could be used as a guide when choosing the solvent for MALDI sample preparation. The highest intensity PVAc signals were obtained when ethyl acetate was used as a solvent along with the lowest matrix-analyte ratio (2,5-dihydroxybenzoic acid was used as a matrix in all experiments). The structure of the PVAc was established with high accuracy using the matrix-assisted laser desorption/ionization-Fourier transform mass spectrometry (MALDI-FTMS) analysis. It was demonstrated that PVAc undergoes unimolecular decomposition by losing acetic acid molecules from its backbone under the conditions of FTMS measurements. Number and weight average molecular weights as well as polydispersity indices were determined with both MALDI-TOF and MALDI-FTMS methods. The sample preparation protocol developed was applied to the analysis of a chewing gum and the molecular weight and structure of the polyvinyl acetate present in the sample were established. Thus, it was shown that optimized MALDI mass spectrometry could be used successfully for characterization of polyvinyl acetate in commercially available chewing gum. Copyright © 2014 Elsevier B.V. All rights reserved.
Sawyer, Kelly N; Kurz, Michael C; Elswick, R K
2014-06-01
Targeted temperature management (TTM) improves outcome after out-of-hospital cardiac arrest (OHCA). We hypothesized that there may be a significant relationship between the dose of hypothermia, the time to return of spontaneous circulation (ROSC), and survival to discharge. Retrospective pilot investigation on 99 consecutive OHCA patients with initial shockable rhythm, surviving to admission, and undergoing TTM between 2008 and 2011. Dose of hypothermia was defined as the sum of the induction interval (time to target temperature [from ROSC to 33°C]); the controlled hypothermia interval (from reaching 33°C until rewarming); and the rewarming interval (from 33°C to 37°C). Time to ROSC was measured from pulselessness or 911 call time to ROSC. The ratio between the two was termed the hypothermic to ischemic ratio. Purposeful variable selection for logistic regression modeling was used to assess the influence of the hypothermic/ischemic ratio on survival. Odds ratios (OR) were used to examine the effects of predictor variables on survival. Of 99 patients, eight were excluded for deviation from protocol, death during protocol, or missing data. From the univariate models, survivors were more likely to be younger, have a shorter time to ROSC, and have a larger hypothermic/ischemic ratio. Survivors also had a nonsignificant trend toward a longer time to target temperature. In multivariable modeling, the hypothermic/ischemic ratio was the most significant predictor for survival (OR 2.161 [95% confidence interval 1.371, 3.404]). In this pilot study, the hypothermic to ischemic ratio was significantly associated with survival to discharge for patients with an initial shockable rhythm. Further investigation of the relationship between the dose of hypothermia and time to ROSC for postresuscitation TTM is needed.
2015-09-01
the network Mac8 Medium Access Control ( Mac ) (Ethernet) address observed as destination for outgoing packets subsessionid8 Zero-based index of...15. SUBJECT TERMS tactical networks, data reduction, high-performance computing, data analysis, big data 16. SECURITY CLASSIFICATION OF: 17...Integer index of row cts_deid Device (instrument) Identifier where observation took place cts_collpt Collection point or logical observation point on
Zimmerman, Christian E.; Nielsen, Roger L.
2003-01-01
The use of strontium-to-calcium (Sr/Ca) ratios in otoliths is becoming a standard method to describe life history type and the chronology of migrations between freshwater and seawater habitats in teleosts (e.g. Kalish, 1990; Radtke et al., 1990; Secor, 1992; Rieman et al., 1994; Radtke, 1995; Limburg, 1995; Tzeng et al. 1997; Volk et al., 2000; Zimmerman, 2000; Zimmerman and Reeves, 2000, 2002). This method provides critical information concerning the relationship and ecology of species exhibiting phenotypic variation in migratory behavior (Kalish, 1990; Secor, 1999). Methods and procedures, however, vary among laboratories because a standard method or protocol for measurement of Sr in otoliths does not exist. In this note, we examine the variations in analytical conditions in an effort to increase precision of Sr/Ca measurements. From these findings we argue that precision can be maximized with higher beam current (although there is specimen damage) than previously recommended by Gunn et al. (1992).
Fiorello, Christine V; Freeman, Kate; Elias, Becky A; Whitmer, Emily; Ziccardi, Michael H
2016-12-15
The safety of chemical dispersants used during oil spill responses is largely unknown in birds. We captured common murres in Monterey Bay, CA and exposed them to Corexit EC9500a, crude oil, or a combination in artificial seawater. We performed ophthalmic examinations and measured intraocular pressures and tear production before and after exposure. Loglinear analysis found that exposure to oil or dispersant was related to the development of conjunctivitis and corneal ulcers. Odds ratios for birds exposed to oil or dispersant were positive and significant for the development of conjunctivitis, while odds ratios for the development of corneal ulcers were positive and significant only for birds exposed to a high concentration of oil. Ocular exposure to dispersants and petroleum in seabirds may cause conjunctivitis and may play a role in the development of corneal ulcers. These results have implications for policymakers who develop protocols for the use of dispersants during marine oil spills. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kelly, Janet L; Hirsch, Irl B; Furnary, Anthony P
2006-01-01
Diabetes mellitus is the fourth most common comorbid condition among hospitalized patients, and 30% of patients undergoing open-heart surgery have diabetes. The link between hyperglycemia and poor outcome has been well described, and large clinical trials have shown that aggressive control of blood glucose with an insulin infusion can improve these outcomes. The barriers to implementing an insulin infusion protocol are numerous, despite the fact that doing so is paramount to clinical success. Barriers include safety concerns, such as fear of hypoglycemia, insufficient nursing staff to patient ratios, lack of administrative and physician support, various system and procedural issues, and resistance to change. Key steps to overcome the barriers include building support with multidisciplinary champions, involving key staff, educating staff, and administrators of the clinical and economic benefits of improving glycemic control, setting realistic goals, selecting a validated insulin infusion protocol, and internally marketing the success of the protocol.
Hao, Kun; Jin, Zhigang; Shen, Haifeng; Wang, Ying
2015-05-28
Efficient routing protocols for data packet delivery are crucial to underwater sensor networks (UWSNs). However, communication in UWSNs is a challenging task because of the characteristics of the acoustic channel. Network coding is a promising technique for efficient data packet delivery thanks to the broadcast nature of acoustic channels and the relatively high computation capabilities of the sensor nodes. In this work, we present GPNC, a novel geographic routing protocol for UWSNs that incorporates partial network coding to encode data packets and uses sensor nodes' location information to greedily forward data packets to sink nodes. GPNC can effectively reduce network delays and retransmissions of redundant packets causing additional network energy consumption. Simulation results show that GPNC can significantly improve network throughput and packet delivery ratio, while reducing energy consumption and network latency when compared with other routing protocols.
Sabarudin, Akmal; Sun, Zhonghua; Yusof, Ahmad Khairuddin Md
2013-09-30
This study is conducted to investigate and compare image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated coronary CT angiography (CCTA) with the use of single-source CT (SSCT) and dual-source CT (DSCT). A total of 209 patients who underwent CCTA with suspected coronary artery disease scanned with SSCT (n=95) and DSCT (n=114) scanners using prospective ECG-triggered and retrospective ECG-gated protocols were recruited from two institutions. The image was assessed by two experienced observers, while quantitative assessment was performed by measuring the image noise, the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). Effective dose was calculated using the latest published conversion coefficient factor. A total of 2087 out of 2880 coronary artery segments were assessable, with 98.0% classified as of sufficient and 2.0% as of insufficient image quality for clinical diagnosis. There was no significant difference in overall image quality between prospective ECG-triggered and retrospective gated protocols, whether it was performed with DSCT or SSCT scanners. Prospective ECG-triggered protocol was compared in terms of radiation dose calculation between DSCT (6.5 ± 2.9 mSv) and SSCT (6.2 ± 1.0 mSv) scanners and no significant difference was noted (p=0.99). However, the effective dose was significantly lower with DSCT (18.2 ± 8.3 mSv) than with SSCT (28.3 ± 7.0 mSv) in the retrospective gated protocol. Prospective ECG-triggered CCTA reduces radiation dose significantly compared to retrospective ECG-gated CCTA, while maintaining good image quality. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Emulation Platform for Cyber Analysis of Wireless Communication Network Protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Leeuwen, Brian P.; Eldridge, John M.
Wireless networking and mobile communications is increasing around the world and in all sectors of our lives. With increasing use, the density and complexity of the systems increase with more base stations and advanced protocols to enable higher data throughputs. The security of data transported over wireless networks must also evolve with the advances in technologies enabling more capable wireless networks. However, means for analysis of the effectiveness of security approaches and implementations used on wireless networks are lacking. More specifically a capability to analyze the lower-layer protocols (i.e., Link and Physical layers) is a major challenge. An analysis approachmore » that incorporates protocol implementations without the need for RF emissions is necessary. In this research paper several emulation tools and custom extensions that enable an analysis platform to perform cyber security analysis of lower layer wireless networks is presented. A use case of a published exploit in the 802.11 (i.e., WiFi) protocol family is provided to demonstrate the effectiveness of the described emulation platform.« less
Gagnon, Keith T.; Li, Liande; Janowski, Bethany A.; Corey, David R.
2014-01-01
RNA interference (RNAi) is well known for its ability to regulate gene expression in the cytoplasm of mammalian cells. In mammalian cell nuclei, however, the impact of RNAi has remained more controversial. A key technical hurdle has been a lack of optimized protocols for the isolation and analysis of cell nuclei. Here we describe a simplified protocol for nuclei isolation from cultured cells that incorporates a method for obtaining nucleoplasmic and chromatin fractions and removing cytoplasmic contamination. Cell fractions can then be used to detect the presence and activity of RNAi factors in the nucleus. We present a protocol for investigating an early step in RNAi, Argonaute protein loading with small RNAs, which is enabled by our improved extract preparations. These protocols facilitate characterization of nuclear RNAi and can be applied to the analysis of other nuclear proteins and pathways. From cellular fractionation to analysis of Argonaute loading results, this protocol takes 4–6 d to complete. PMID:25079428
Toftager, Mette; Sylvest, Randi; Schmidt, Lone; Bogstad, Jeanette; Løssl, Kristine; Prætorius, Lisbeth; Zedeler, Anne; Bryndorf, Thue; Pinborg, Anja
2018-01-01
To compare self-reported quality of life, psychosocial well-being, and physical well-being during assisted reproductive technology (ART) treatment in 1,023 women allocated to either a short GnRH antagonist or long GnRH agonist protocol. Secondary outcome of a prospective phase 4, open-label, randomized controlled trial. Four times during treatment a questionnaire on self-reported physical well-being was completed. Further, a questionnaire on self-reported quality of life and psychosocial well-being was completed at the day of hCG testing. Fertility clinics at university hospitals. Women referred for their first ART treatment were randomized in a 1:1 ratio and started standardized ART protocols. Gonadotropin-releasing hormone analogue; 528 women allocated to a short GnRH antagonist protocol and 495 women allocated to a long GnRH agonist protocol. Self-reported quality of life, psychosocial well-being, and physical well-being based on questionnaires developed for women receiving ART treatment. Baseline characteristics were similar, and response rates were 79.4% and 74.3% in the GnRH antagonist and GnRH agonist groups, respectively. Self-reported quality of life during ART treatment was rated similar and slightly below normal in both groups. However, women in the GnRH antagonist group felt less emotional (adjusted odds ratio [AOR] 0.69), less limited in their everyday life (AOR 0.74), experienced less unexpected crying (AOR 0.71), and rated quality of sleep better (AOR 1.55). Further, women receiving GnRH agonist treatment felt worse physically. Women in a short GnRH antagonist protocol rated psychosocial and physical well-being during first ART treatment better than did women in a long GnRH agonist protocol. However, the one item on self-reported general quality of life was rated similarly. NCT00756028. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
2014-01-01
Background Single-pass, contrast-enhanced whole body multidetector computed tomography (MDCT) emerged as the diagnostic standard for evaluating patients with major trauma. Modern iterative image algorithms showed high image quality at a much lower radiation dose in the non-trauma setting. This study aims at investigating whether the radiation dose can safely be reduced in trauma patients without compromising the diagnostic accuracy and image quality. Methods/Design Prospective observational study with two consecutive cohorts of patients. Setting: A high-volume, academic, supra-regional trauma centre in Germany. Study population: Consecutive male and female patients who 1. had been exposed to a high-velocity trauma mechanism, 2. present with clinical evidence or high suspicion of multiple trauma (predicted Injury Severity Score [ISS] ≥16) and 3. are scheduled for primary MDCT based on the decision of the trauma leader on call. Imaging protocols: In a before/after design, a consecutive series of 500 patients will undergo single-pass, whole-body 128-row multi-detector computed tomography (MDCT) with a standard, as low as possible radiation dose. This will be followed by a consecutive series of 500 patients undergoing an approved ultra-low dose MDCT protocol using an image processing algorithm. Data: Routine administrative data and electronic patient records, as well as digital images stored in a picture archiving and communications system will serve as the primary data source. The protocol was approved by the institutional review board. Main outcomes: (1) incidence of delayed diagnoses, (2) diagnostic accuracy, as correlated to the reference standard of a synopsis of all subsequent clinical, imaging, surgical and autopsy findings, (3) patients’ safety, (4) radiation exposure (e.g. effective dose), (5) subjective image quality (assessed independently radiologists and trauma surgeons on a 100-mm visual analogue scale), (6) objective image quality (e.g., contrast-to-noise ratio). Analysis: Multivariate regression will be employed to adjust and correct the findings for time and cohort effects. An exploratory interim analysis halfway after introduction of low-dose MDCT will be conducted to assess whether this protocol is clearly inferior or superior to the current standard. Discussion Although non-experimental, this study will generate first large-scale data on the utility of imaging-enhancing algorithms in whole-body MDCT for major blunt trauma. Trial registration Current Controlled Trials ISRCTN74557102. PMID:24589310
Effect of different analyte diffusion/adsorption protocols on SERS signals
NASA Astrophysics Data System (ADS)
Li, Ruoping; Petschek, Rolfe G.; Han, Junhe; Huang, Mingju
2018-07-01
The effect of different analyte diffusion/adsorption protocols was studied which is often overlooked in surface-enhanced Raman scattering (SERS) technique. Three protocols: highly concentrated dilution (HCD) protocol, half-half dilution (HHD) protocol and layered adsorption (LA) protocol were studied and the SERS substrates were monolayer films of 80 nm Ag nanoparticles (NPs) which were modified by polyvinylpyrrolidone. The diffusion/adsorption mechanisms were modelled using the diffusion equation and the electromagnetic field distribution of two adjacent Ag NPs was simulated by the finite-different time-domain method. All experimental data and theoretical analysis suggest that different diffusion/adsorption behaviour of analytes will cause different SERS signal enhancements. HHD protocol could produce the most uniform and reproducible samples, and the corresponding signal intensity of the analyte is the strongest. This study will help to understand and promote the use of SERS technique in quantitative analysis.
Anti-Noise Bidirectional Quantum Steganography Protocol with Large Payload
NASA Astrophysics Data System (ADS)
Qu, Zhiguo; Chen, Siyi; Ji, Sai; Ma, Songya; Wang, Xiaojun
2018-06-01
An anti-noise bidirectional quantum steganography protocol with large payload protocol is proposed in this paper. In the new protocol, Alice and Bob enable to transmit classical information bits to each other while teleporting secret quantum states covertly. The new protocol introduces the bidirectional quantum remote state preparation into the bidirectional quantum secure communication, not only to expand secret information from classical bits to quantum state, but also extract the phase and amplitude values of secret quantum state for greatly enlarging the capacity of secret information. The new protocol can also achieve better imperceptibility, since the eavesdropper can hardly detect the hidden channel or even obtain effective secret quantum states. Comparing with the previous quantum steganography achievements, due to its unique bidirectional quantum steganography, the new protocol can obtain higher transmission efficiency and better availability. Furthermore, the new algorithm can effectively resist quantum noises through theoretical analysis. Finally, the performance analysis proves the conclusion that the new protocol not only has good imperceptibility, high security, but also large payload.
Anti-Noise Bidirectional Quantum Steganography Protocol with Large Payload
NASA Astrophysics Data System (ADS)
Qu, Zhiguo; Chen, Siyi; Ji, Sai; Ma, Songya; Wang, Xiaojun
2018-03-01
An anti-noise bidirectional quantum steganography protocol with large payload protocol is proposed in this paper. In the new protocol, Alice and Bob enable to transmit classical information bits to each other while teleporting secret quantum states covertly. The new protocol introduces the bidirectional quantum remote state preparation into the bidirectional quantum secure communication, not only to expand secret information from classical bits to quantum state, but also extract the phase and amplitude values of secret quantum state for greatly enlarging the capacity of secret information. The new protocol can also achieve better imperceptibility, since the eavesdropper can hardly detect the hidden channel or even obtain effective secret quantum states. Comparing with the previous quantum steganography achievements, due to its unique bidirectional quantum steganography, the new protocol can obtain higher transmission efficiency and better availability. Furthermore, the new algorithm can effectively resist quantum noises through theoretical analysis. Finally, the performance analysis proves the conclusion that the new protocol not only has good imperceptibility, high security, but also large payload.
A Secure Region-Based Geographic Routing Protocol (SRBGR) for Wireless Sensor Networks
Adnan, Ali Idarous; Hanapi, Zurina Mohd; Othman, Mohamed; Zukarnain, Zuriati Ahmad
2017-01-01
Due to the lack of dependency for routing initiation and an inadequate allocated sextant on responding messages, the secure geographic routing protocols for Wireless Sensor Networks (WSNs) have attracted considerable attention. However, the existing protocols are more likely to drop packets when legitimate nodes fail to respond to the routing initiation messages while attackers in the allocated sextant manage to respond. Furthermore, these protocols are designed with inefficient collection window and inadequate verification criteria which may lead to a high number of attacker selections. To prevent the failure to find an appropriate relay node and undesirable packet retransmission, this paper presents Secure Region-Based Geographic Routing Protocol (SRBGR) to increase the probability of selecting the appropriate relay node. By extending the allocated sextant and applying different message contention priorities more legitimate nodes can be admitted in the routing process. Moreover, the paper also proposed the bound collection window for a sufficient collection time and verification cost for both attacker identification and isolation. Extensive simulation experiments have been performed to evaluate the performance of the proposed protocol in comparison with other existing protocols. The results demonstrate that SRBGR increases network performance in terms of the packet delivery ratio and isolates attacks such as Sybil and Black hole. PMID:28121992
A Secure Region-Based Geographic Routing Protocol (SRBGR) for Wireless Sensor Networks.
Adnan, Ali Idarous; Hanapi, Zurina Mohd; Othman, Mohamed; Zukarnain, Zuriati Ahmad
2017-01-01
Due to the lack of dependency for routing initiation and an inadequate allocated sextant on responding messages, the secure geographic routing protocols for Wireless Sensor Networks (WSNs) have attracted considerable attention. However, the existing protocols are more likely to drop packets when legitimate nodes fail to respond to the routing initiation messages while attackers in the allocated sextant manage to respond. Furthermore, these protocols are designed with inefficient collection window and inadequate verification criteria which may lead to a high number of attacker selections. To prevent the failure to find an appropriate relay node and undesirable packet retransmission, this paper presents Secure Region-Based Geographic Routing Protocol (SRBGR) to increase the probability of selecting the appropriate relay node. By extending the allocated sextant and applying different message contention priorities more legitimate nodes can be admitted in the routing process. Moreover, the paper also proposed the bound collection window for a sufficient collection time and verification cost for both attacker identification and isolation. Extensive simulation experiments have been performed to evaluate the performance of the proposed protocol in comparison with other existing protocols. The results demonstrate that SRBGR increases network performance in terms of the packet delivery ratio and isolates attacks such as Sybil and Black hole.
A comparison of protocols and observer precision for measuring physical stream attributes
Whitacre, H.W.; Roper, B.B.; Kershner, J.L.
2007-01-01
Stream monitoring programs commonly measure physical attributes to assess the effect of land management on stream habitat. Variability associated with the measurement of these attributes has been linked to a number of factors, but few studies have evaluated variability due to differences in protocols. We compared six protocols, five used by the U.S. Department of Agriculture Forest Service and one by the U.S. Environmental Protection Agency, on six streams in Oregon and Idaho to determine whether differences in protocol affect values for 10 physical stream attributes. Results from Oregon and Idaho were combined for groups participating in both states, with significant differences in attribute means for 9 out of the 10 stream attributes. Significant differences occurred in 5 of 10 in Idaho, and 10 of 10 in Oregon. Coefficients of variation, signal-to-noise ratio, and root mean square error were used to evaluate measurement precision. There were differences among protocols for all attributes when states were analyzed separately and as a combined dataset. Measurement differences were influenced by choice of instruments, measurement method, measurement location, attribute definitions, and training approach. Comparison of data gathered by observers using different protocols will be difficult unless a core set of protocols for commonly measured stream attributes can be standardized among monitoring programs.
Huang, Yan; Van Dessel, Jeroen; Liang, Xin; Depypere, Maarten; Zhong, Weijian; Ma, Guowu; Lambrichts, Ivo; Maes, Frederik; Jacobs, Reinhilde
2014-12-01
To develop a method for characterizing trabecular bone microarchitecture using cone beam computed tomography (CBCT) and to evaluate trabecular bone changes after rehabilitation using immediate versus delayed implant protocols. Six mongrel dogs randomly received 27 titanium implants in the maxillary incisor or mandibular premolar areas, following one of four protocols: (1) normal extraction socket healing; (2) immediate implant placement and immediate loading; (3) delayed implant placement and delayed loading; (4) delayed implant placement and immediate loading. The animals were euthanized at 8 weeks, and block biopsies were scanned using high resolution CBCT. Standard bone structural variables were assessed in coronal, middle, and apical levels. Coronal and middle regions had more compact, more platelike, and thicker trabeculae. Protocols (2), (3), and (4) had significantly higher values (p < 0.001) than protocol (1) for bone surface density, bone surface volume ratio, and connectivity density, while significantly lower values (p < 0.001) were found for trabecular separation and fractal dimension. However, protocols (2), (3), and (4) did not show significantly different bone remodeling. Compared with normal extraction healing, the implant protocols have an improved bone structural integration. Results do not suggest a different bone remodeling pattern when a delayed versus an immediate implant protocol is used. © 2013 Wiley Periodicals, Inc.
Ediani Machado, Michely; Tomazoni, Fernanda; Ruffo Ortiz, Fernanda; Ardenghi, Thiago Machado; Zanatta, Fabricio Batistin
2017-07-01
It is not clear how using partial-mouth periodontal examination (PMPE) protocols affects estimates of the association between gingival bleeding (GB) and oral health-related quality of life (OHRQoL). The aim of the present study is to assess impact of different PMPEs on the association between GB and OHRQoL in 12-year-old adolescents. A total of 1,134 adolescents were evaluated for clinical and subjective variables. GB was determined by full-mouth examination (FME) of six sites (disto-buccal [DB], mid-buccal [B], mesio-buccal [MB], disto-lingual [DL], mid-lingual, and mesio-lingual [ML]) and different PMPEs were calculated using a 15% cut-off point: 1) full-mouth (MB-B-DB/MB-B-DL); 2) two diagonal quadrants (six sites/MB-B-DB/MB-B-DL); 3) two randomly selected half-mouth quadrants (six sites/MB-B-DB/ MB-B-DL/MB-DB-ML-DL); and 4) the community periodontal index. OHRQoL was assessed using the Child Perceptions Questionnaire (CPQ 11-14 ). Adjusted negative binomial regression models were used to calculate the rate ratio of CPQ 11-14 scores for each PMPE. Adolescents with GB showed significantly poorer OHRQoL than their counterparts when FME was used. In contrast, more than half of PMPE protocols did not detect significant associations between GB and CPQ 11-14 scores in the adjusted analysis. Using PMPE to assess GB in adolescents significantly affects associations with OHRQoL outcomes, depending on the protocol used. PMPEs that evaluated MB-B-DL sites of randomly selected half-mouth quadrants (1 or 2 and 3 or 4) achieved results closer to those obtained with FME.
T2AR: trust-aware ad-hoc routing protocol for MANET.
Dhananjayan, Gayathri; Subbiah, Janakiraman
2016-01-01
Secure data transfer against the malicious attacks is an important issue in an infrastructure-less independent network called mobile ad-hoc network (MANET). Trust assurance between MANET nodes is the key parameter in the high-security provision under dynamic topology variations and open wireless constraints. But, the malicious behavior of nodes reduces the trust level of the nodes that leads to an insecure data delivery. The increase in malicious attacks causes the excessive energy consumption that leads to a reduction of network lifetime. The lack of positional information update of the nodes in ad-hoc on-demand vector (AODV) protocol during the connection establishment offers less trust level between the nodes. Hence, the trust rate computation using energy and mobility models and its update are the essential tasks for secure data delivery. This paper proposes a trust-aware ad-hoc routing (T2AR) protocol to improve the trust level between the nodes in MANET. The proposed method modifies the traditional AODV routing protocol with the constraints of trust rate, energy, mobility based malicious behavior prediction. The packet sequence ID matching from the log reports of neighbor nodes determine the trust rate that avoids the malicious report generation. Besides, the direct and indirect trust observation schemes utilization increases the trust level. Besides, the received signal strength indicator utilization determines the trusted node is within the communication range or not. The comparative analysis between the proposed T2AR with the existing methods such as TRUNCMAN, RBT, GR, FBR and DICOTIDS regarding the average end-to-end delay, throughput, false positives, packet delivery ratio shows the effectiveness of T2AR in the secure MANET environment design.
Dy, Jessica; Rainey, Jenna; Walker, Mark C; Fraser, William; Smith, Graeme N; White, Ruth Rennicks; Waddell, Patti; Janoudi, Ghayath; Corsi, Daniel J; Wei, Shu Qin
2018-06-01
The primary objective was to determine the feasibility of a large RCT assessing the effectiveness of an accelerated oxytocin titration (AOT) protocol compared with a standard gradual oxytocin titration (GOT) in reducing the risk of CS in nulliparous women diagnosed with dystocia in the first stage of labour. The secondary objective was to obtain preliminary data on the safety and efficacy of the foregoing AOT protocol. This was a multicentre, double-masked, parallel-group pilot RCT. This study was conducted in three Canadian birthing centres. A total of 79 term nulliparous women carrying a singleton pregnancy in spontaneous labour, with a diagnosis of labour dystocia, were randomized to receive either GOT (initial dose 2 mU/min with increments of 2 mU/min) or AOT (initial dose 4 mU/min with increments of 4 mU/min), in a 1:1 ratio. An intention-to-treat analysis was applied. A total of 252 women were screened and approached, 137 (54.4%) consented, and 79 (31.3%) were randomized. Overall protocol adherence was 76 of 79 (96.2%). Of the women randomized, 10 (25.6%) allocated to GOT had a CS compared with six (15.0%) allocated to AOT (Fisher exact test P = 0.27). This pilot study demonstrated that a large, multicentre RCT is not only feasible, but also necessary to assess the effectiveness and safety of an AOT protocol for labour augmentation with regard to CS rate and indicators of maternal and perinatal morbidities. Copyright © 2018 Society of Obstetricians and Gynaecologists of Canada. Published by Elsevier Inc. All rights reserved.
Duan, Yongbo; Zhai, Chenguang; Li, Hao; Li, Juan; Mei, Wenqian; Gui, Huaping; Ni, Dahu; Song, Fengshun; Li, Li; Zhang, Wanggen; Yang, Jianbo
2012-09-01
A number of Agrobacterium-mediated rice transformation systems have been developed and widely used in numerous laboratories and research institutes. However, those systems generally employ antibiotics like kanamycin and hygromycin, or herbicide as selectable agents, and are used for the small-scale experiments. To address high-throughput production of transgenic rice plants via Agrobacterium-mediated transformation, and to eliminate public concern on antibiotic markers, we developed a comprehensive efficient protocol, covering from explant preparation to the acquisition of low copy events by real-time PCR analysis before transplant to field, for high-throughput production of transgenic plants of Japonica rice varieties Wanjing97 and Nipponbare using Escherichia coli phosphomannose isomerase gene (pmi) as a selectable marker. The transformation frequencies (TF) of Wanjing97 and Nipponbare were achieved as high as 54.8 and 47.5%, respectively, in one round of selection of 7.5 or 12.5 g/L mannose appended with 5 g/L sucrose. High-throughput transformation from inoculation to transplant of low copy events was accomplished within 55-60 days. Moreover, the Taqman assay data from a large number of transformants showed 45.2% in Wanjing97 and 31.5% in Nipponbare as a low copy rate, and the transformants are fertile and follow the Mendelian segregation ratio. This protocol facilitates us to perform genome-wide functional annotation of the open reading frames and utilization of the agronomically important genes in rice under a reduced public concern on selectable markers. We describe a comprehensive protocol for large scale production of transgenic Japonica rice plants using non-antibiotic selectable agent, at simplified, cost- and labor-saving manners.
Meda, John; Kalluvya, Samuel; Downs, Jennifer A; Chofle, Awilly A; Seni, Jeremiah; Kidenya, Benson; Fitzgerald, Daniel W; Peck, Robert N
2014-06-01
Cryptococcal meningitis (CM) has a mortality rate of ∼70% among HIV-infected adults in low-income countries. Controlling intracranial pressure (ICP) is essential in CM, but it is difficult in low-income countries because manometers and practical ICP management protocols are lacking. As part of a continuous quality improvement project, our Tanzanian hospital initiated a new protocol for ICP management for CM. All adult inpatients with CM are included in a prospective patient registry. At the time of analysis, this registry included data from 2 years before the initiation of this new ICP management protocol and for a 9-month period after. ICP was measured at baseline and at days 3, 7, and 14 by both manometer and intravenous (IV) tubing set. All patients were given IV fluconazole according to Tanzanian treatment guidelines and were followed until 30 days after admission. Among adult inpatients with CM, 32 of 35 patients (91%) had elevated ICP on admission. Cerebrospinal fluid pressure measurements using the improvised IV tubing set demonstrated excellent agreement (r = 0.96) with manometer measurements. Compared with historical controls, the new ICP management protocol was associated with a significant reduction in 30-day mortality (16/35 [46%] vs. 48/64 [75%] in historical controls; hazard ratio = 2.1 [95% CI: 1.1 to 3.8]; P = 0.018]. Increased ICP is almost universal among HIV-infected adults admitted with CM in Tanzania. Intensive ICP management with a strict schedule of serial lumbar punctures reduced in-hospital mortality compared with historical controls. ICP measurement with IV tubing sets may be a good alternative in resource-limited health facilities where manometers are not available.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahmood, U; Erdi, Y; Wang, W
Purpose: To assess the impact of General Electrics (GE) automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of an adult anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, Auto mA (180 to 380 mA), noise index (NI) = 14, adaptive iterative statistical reconstruction (ASiR) of 20%, 0.8s rotation time. Image quality was evaluated by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACRmore » CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: The CNR for the adult male was found to decrease from CNR = 0.912 ± 0.045 for the baseline protocol without kVa to a CNR = 0.756 ± 0.049 with kVa activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.903 ± 0.023. The difference in the central liver dose with and without kVa was found to be 0.07%. Conclusion: Dose reduction was insignificant in the adult phantom. As determined by NPS analysis, ASiR of 40% produced images with similar noise texture to the baseline protocol. However, the CNR at ASiR of 40% with kVa fails to meet the current ACR CNR passing requirement of 1.0.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahmood, U; Erdi, Y; Wang, W
Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document.more » NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients.« less
The Benefit of Remote Microphones Using Four Wireless Protocols.
Rodemerk, Krishna S; Galster, Jason A
2015-09-01
Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearing aids. As a result, commercial remote microphone systems use a variety of different protocols for wireless audio transmission. It is not known how these systems compare, with regard to adult speech recognition in noise. The primary goal of this investigation was to determine the speech recognition benefits of four different commercially available remote microphone systems, each with a different wireless audio transmission protocol. A repeated-measures design was used in this study. Sixteen adults, ages 52 to 81 yr, with mild to severe sensorineural hearing loss participated in this study. Participants were fit with three different sets of bilateral hearing aids and four commercially available remote microphone systems (FM, 900 MHz, 2.4 GHz, and Bluetooth(®) paired with near-field magnetic induction). Speech recognition scores were measured by an adaptive version of the Hearing in Noise Test (HINT). The participants were seated both 6 and 12' away from the talker loudspeaker. Participants repeated HINT sentences with and without hearing aids and with four commercially available remote microphone systems in both seated positions with and without contributions from the hearing aid or environmental microphone (24 total conditions). The HINT SNR-50, or the signal-to-noise ratio required for correct repetition of 50% of the sentences, was recorded for all conditions. A one-way repeated measures analysis of variance was used to determine statistical significance of microphone condition. The results of this study revealed that use of the remote microphone systems statistically improved speech recognition in noise relative to unaided and hearing aid-only conditions across all four wireless transmission protocols at 6 and 12' away from the talker. Participants showed a significant improvement in speech recognition in noise when comparing four remote microphone systems with different wireless transmission methods to hearing aids alone. American Academy of Audiology.
Comparison: Mediation Solutions of WSMOLX and WebML/WebRatio
NASA Astrophysics Data System (ADS)
Zaremba, Maciej; Zaharia, Raluca; Turati, Andrea; Brambilla, Marco; Vitvar, Tomas; Ceri, Stefano
In this chapter we compare the WSMO/WSML/WSMX andWebML/WebRatio approaches to the SWS-Challenge workshop mediation scenario in terms of the utilized underlying technologies and delivered solutions. In the mediation scenario one partner uses Roset-taNet to define its B2B protocol while the other one operates on a proprietary solution. Both teams shown how these partners could be semantically integrated.
Menditto, Vincenzo G; Lucci, Moira; Polonara, Stefano; Pomponio, Giovanni; Gabrielli, Armando
2012-06-01
Patients receiving warfarin who experience minor head injury are at risk of intracranial hemorrhage, and optimal management after a single head computed tomography (CT) scan is unclear. We evaluate a protocol of 24-hour observation followed by a second head CT scan. In this prospective case series, we enrolled consecutive patients receiving warfarin and showing no intracranial lesions on a first CT scan after minor head injury treated at a Level II trauma center. We implemented a structured clinical pathway, including 24-hour observation and a CT scan performed before discharge. We then evaluated the frequency of death, admission, neurosurgery, and delayed intracranial hemorrhage. We enrolled and observed 97 consecutive patients. Ten refused the second CT scan and were well during 30-day follow-up. Repeated CT scanning in the remaining 87 patients revealed a new hemorrhage lesion in 5 (6%), with 3 subsequently hospitalized and 1 receiving craniotomy. Two patients discharged after completing the study protocol with 2 negative CT scan results were admitted 2 and 8 days later with symptomatic subdural hematomas; neither received surgery. Two of the 5 patients with delayed bleeding at 24 hours had an initial international normalized ratio greater than 3.0, as did both patients with delayed bleeding beyond 24 hours. The relative risk of delayed hemorrhage with an initial international normalized ratio greater than 3.0 was 14 (95% confidence interval 4 to 49). For patients receiving warfarin who experience minor head injury and have a negative initial head CT scan result, a protocol of 24-hour observation followed by a second CT scan will identify most occurrences of delayed bleeding. An initial international normalized ratio greater than 3 suggests higher risk. Copyright © 2011 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Automating Security Protocol Analysis
2004-03-01
language that allows easy representation of pattern interaction. Using CSP, Lowe tests whether a protocol achieves authentication. In the case of...only to correctly code whatever protocol they intend to evaluate. The tool, OCaml 3.04 [1], translates the protocol into Horn clauses and then...model protocol transactions. One example of automated modeling software is Maude [19]. Maude was the intended language for this research, but Java
Validation of a school-based amblyopia screening protocol in a kindergarten population.
Casas-Llera, Pilar; Ortega, Paula; Rubio, Inmaculada; Santos, Verónica; Prieto, María J; Alio, Jorge L
2016-08-04
To validate a school-based amblyopia screening program model by comparing its outcomes to those of a state-of-the-art conventional ophthalmic clinic examination in a kindergarten population of children between the ages of 4 and 5 years. An amblyopia screening protocol, which consisted of visual acuity measurement using Lea charts, ocular alignment test, ocular motility assessment, and stereoacuity with TNO random-dot test, was performed at school in a pediatric 4- to 5-year-old population by qualified healthcare professionals. The outcomes were validated in a selected group by a conventional ophthalmologic examination performed in a fully equipped ophthalmologic center. The ophthalmologic evaluation was used to confirm whether or not children were correctly classified by the screening protocol. The sensitivity and specificity of the test model to detect amblyopia were established. A total of 18,587 4- to 5-year-old children were subjected to the amblyopia screening program during the 2010-2011 school year. A population of 100 children were selected for the ophthalmologic validation screening. A sensitivity of 89.3%, specificity of 93.1%, positive predictive value of 83.3%, negative predictive value of 95.7%, positive likelihood ratio of 12.86, and negative likelihood ratio of 0.12 was obtained for the amblyopia screening validation model. The amblyopia screening protocol model tested in this investigation shows high sensitivity and specificity in detecting high-risk cases of amblyopia compared to the standard ophthalmologic examination. This screening program may be highly relevant for amblyopia screening at schools.
Ter Wee, Marieke M; Coupé, Veerle Mh; den Uyl, Debby; Blomjous, Birgit S; Kooijmans, Esmee; Kerstens, Pit Jsm; Nurmohamed, Mike T; van Schaardenburg, Dirkjan; Voskuyl, Alexandre E; Boers, Maarten; Lems, Willem F
2017-01-01
To evaluate if COmbinatie therapie Bij Reumatoïde Artritis (COBRA)-light therapy is cost-effective in treating patients with early rheumatoid arthritis (RA) compared with COBRA therapy. This economic evaluation was performed next to the open-label, randomised non-inferiority COBRA-light trial in 164 patients with early RA. Non-responders to COBRA or COBRA-light received etanercept (50 mg/week) for 3-6 months. The societal perspective analysis took medical direct, non-medical direct and indirect costs into account. Costs were measured with patient cost diaries for the follow-up period of 52 weeks. Bootstrapping techniques estimated uncertainty around the cost-effectiveness ratios, presented in cost-effectiveness planes. 164 patients were randomised to either COBRA or COBRA-light strategy. At week 52, COBRA-light proved to be non-inferior to COBRA therapy on all clinical outcome measures. The results of the base-case cost-utility analysis (intention-to-treat analyses) revealed that COBRA-light strategy is more expensive (k€9.3 (SD 0.9) compared with COBRA (k€7.2 (SD 0.8)), but the difference in costs were not significant (k€2.0; 95% CI -0.3 to 4.4). Also, both strategies produced similar quality-adjusted life-years (QALYs). The sensitivity analyses showed robustness of these results. In a per-protocol sensitivity analysis, in which costs of etanercept were assumed to be provided as prescribed according to protocol, both arms had much higher costs: COBRA-light: k€11.5 (8.3) compared with k€8.5 (6.8) for COBRA, and the difference in costs was significant (k€2.9; 0.6 to 5.3). In the base-case cost-utility analysis, the two strategies produced similar QALYs for similar costs. But it is anticipated that if protocol had been followed correctly, the COBRA-light strategy would have been more costly due to additional etanercept costs, for a limited health gain. Given the limited added benefit and high costs of starting etanercept in the presence of low disease activity in our trial, such a strategy needs better justification than is available now. 55552928, Results.
Tan, Whye Kit; Lee, Sang-Gon; Lam, Jun Huy; Yoo, Seong-Moo
2013-01-01
Wireless mesh networks (WMNs) can act as a scalable backbone by connecting separate sensor networks and even by connecting WMNs to a wired network. The Hybrid Wireless Mesh Protocol (HWMP) is the default routing protocol for the 802.11s WMN. The routing protocol is one of the most important parts of the network, and it requires protection, especially in the wireless environment. The existing security protocols, such as the Broadcast Integrity Protocol (BIP), Counter with cipher block chaining message authentication code protocol (CCMP), Secure Hybrid Wireless Mesh Protocol (SHWMP), Identity Based Cryptography HWMP (IBC-HWMP), Elliptic Curve Digital Signature Algorithm HWMP (ECDSA-HWMP), and Watchdog-HWMP aim to protect the HWMP frames. In this paper, we have analyzed the vulnerabilities of the HWMP and developed security requirements to protect these identified vulnerabilities. We applied the security requirements to analyze the existing secure schemes for HWMP. The results of our analysis indicate that none of these protocols is able to satisfy all of the security requirements. We also present a quantitative complexity comparison among the protocols and an example of a security scheme for HWMP to demonstrate how the result of our research can be utilized. Our research results thus provide a tool for designing secure schemes for the HWMP. PMID:24002231
Tan, Whye Kit; Lee, Sang-Gon; Lam, Jun Huy; Yoo, Seong-Moo
2013-09-02
Wireless mesh networks (WMNs) can act as a scalable backbone by connecting separate sensor networks and even by connecting WMNs to a wired network. The Hybrid Wireless Mesh Protocol (HWMP) is the default routing protocol for the 802.11s WMN. The routing protocol is one of the most important parts of the network, and it requires protection, especially in the wireless environment. The existing security protocols, such as the Broadcast Integrity Protocol (BIP), Counter with cipher block chaining message authentication code protocol (CCMP), Secure Hybrid Wireless Mesh Protocol (SHWMP), Identity Based Cryptography HWMP (IBC-HWMP), Elliptic Curve Digital Signature Algorithm HWMP (ECDSA-HWMP), and Watchdog-HWMP aim to protect the HWMP frames. In this paper, we have analyzed the vulnerabilities of the HWMP and developed security requirements to protect these identified vulnerabilities. We applied the security requirements to analyze the existing secure schemes for HWMP. The results of our analysis indicate that none of these protocols is able to satisfy all of the security requirements. We also present a quantitative complexity comparison among the protocols and an example of a security scheme for HWMP to demonstrate how the result of our research can be utilized. Our research results thus provide a tool for designing secure schemes for the HWMP.
Francis, Arul Prakash; Murthy, Prakhya Balakishna; Devas, Thiyagarajan
2014-07-01
We have optimized a protocol for the preparation of bisdemethoxy curcumin analog nanoparticles (BDMCA-NP) by the solvent assisted process. The structural similarities between bulk and nano BDMCA were determined by Co-TLC, NMR and F-TIR. This shows that our synthesis protocol enhanced the dispersibility and reduce the size of BDMCA without altering the integrity of functional moieties and structure, which is crucial for anticancer and antioxidant activities. The morphology and size of BDMCA-NP as determined by SEM, HRTEM and DLS was found to be around 80 nm. BDMCA-NP treated breast cancer cell lines (MCF 7) showed cell death as characterized by MTT assay. Flow cytometric analysis of BDMCA-NP treated MCF 7 cell lines showed an increase of cell count in G2/M phase indicates the cell cycle arrest. Western blot analysis revealed the presence of caspase 3, caspase 9, cleaved fragments of PARP and Bax proteins in the BDMCA-NP treated MCF 7 cell lines, but not in untreated cell lines. To recap, we have prepared BDMCA-NP by solvent assisted process, which exerted anticancer activity against breast cancer cells, which may be due to (i) enhanced dispersibility and surface: volume ratio, (ii) apoptosis (iii) mitochondrial pathway induced cell death, (iv) G2/M phase cell cycle arrest and (v) disassembly of mitotic spindle of the cancer cells. Thus, nano BDMCA can be used as a potent anticancer agent.
Gallistel, C. R.; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam
2014-01-01
We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer. PMID:24637442
Gallistel, C R; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam
2014-02-26
We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer.
Kohara, Norihito; Kaneko, Masayuki; Narukawa, Mamoru
2018-01-01
The concept of the risk-based approach has been introduced as an effort to secure the quality of clinical trials. In the risk-based approach, identification and evaluation of risk in advance are considered important. For recently completed clinical trials, we investigated the relationship between study characteristics and protocol deviations leading to the exclusion of subjects from Per Protocol Set (PPS) efficacy analysis. New drugs approved in Japan in the fiscal year 2014-2015 were targeted in the research. The reasons for excluding subjects from the PPS efficacy analysis were described in 102 trials out of 492 in the summary of new drug application documents, which was publicly disclosed after the drug's regulatory approval. The author extracted these reasons along with the numbers of the cases and the study characteristics of each clinical trial. Then, the direct comparison, univariate regression analysis, and multivariate regression analysis was carried out based on the exclusion rate. The study characteristics for which exclusion of subjects from the PPS efficacy analysis were frequently observed was multiregional clinical trials in study region; inhalant and external use in administration route; Anti-infective for systemic use; Respiratory system, Dermatologicals, and Nervous system in therapeutic drug under the Anatomical Therapeutic Chemical Classification. In the multivariate regression analysis, the clinical trial variables of inhalant, Respiratory system, or Dermatologicals were selected as study characteristics leading to a higher exclusion rate. The characteristics of the clinical trial that is likely to cause protocol deviations that will affect efficacy analysis were suggested. These studies should be considered for specific attention and priority observation in the trial protocol or its monitoring plan and execution, such as a clear description of inclusion/exclusion criteria in the protocol, development of training materials to site staff, and/or trial subjects as specific risk-alleviating measures.
Ogawa, Tetsuya; Yamamoto, Shin-Ichiro; Nakazawa, Kimitaka
2018-01-01
The adaptability of human bipedal locomotion has been studied using split-belt treadmill walking. Most of previous studies utilized experimental protocol under remarkably different split ratios (e.g. 1:2, 1:3, or 1:4). While, there is limited research with regard to adaptive process under the small speed ratios. It is important to know the nature of adaptive process under ratio smaller than 1:2, because systematic evaluation of the gait adaptation under small to moderate split ratios would enable us to examine relative contribution of two forms of adaptation (reactive feedback and predictive feedforward control) on gait adaptation. We therefore examined a gait behavior due to on split-belt treadmill adaptation under five belt speed difference conditions (from 1:1.2 to 1:2). Gait parameters related to reactive control (stance time) showed quick adjustments immediately after imposing the split-belt walking in all five speed ratios. Meanwhile, parameters related to predictive control (step length and anterior force) showed a clear pattern of adaptation and subsequent aftereffects except for the 1:1.2 adaptation. Additionally, the 1:1.2 ratio was distinguished from other ratios by cluster analysis based on the relationship between the size of adaptation and the aftereffect. Our findings indicate that the reactive feedback control was involved in all the speed ratios tested and that the extent of reaction was proportionally dependent on the speed ratio of the split-belt. On the contrary, predictive feedforward control was necessary when the ratio of the split-belt was greater. These results enable us to consider how a given split-belt training condition would affect the relative contribution of the two strategies on gait adaptation, which must be considered when developing rehabilitation interventions for stroke patients. PMID:29694404
Alvarez-Cuesta, E; Madrigal-Burgaleta, R; Angel-Pereira, D; Ureña-Tavera, A; Zamora-Verduga, M; Lopez-Gonzalez, P; Berges-Gimeno, M P
2015-07-01
Evidence regarding drug provocation test (DPT) with antineoplastic and biological agents is scarce. Our aim was to assess the usefulness of including DPT as a paramount gold standard diagnostic tool (prior to desensitization). Prospective, observational, longitudinal study with patients who, during a 3-year period, were referred to the Desensitization Program at Ramon y Cajal University Hospital. Patients underwent a structured diagnostic protocol by means of anamnesis, skin tests (ST), risk assessment, and DPT. Oxaliplatin-specific IgE was determined in oxaliplatin-reactive patients (who underwent DPT regardless of oxaliplatin-specific IgE results). Univariate analysis and multivariate analysis were used to identify predictors of the final diagnosis among several variables. A total of 186 patients were assessed. A total of 104 (56%) patients underwent DPT. Sixty-four percent of all DPTs were negative (i.e., hypersensitivity was excluded). Sensitivity for oxaliplatin-specific IgE (0.35 UI/l cutoff point) was 34%, specificity 90.3%, negative predictive value 45.9%, positive predictive value 85%, negative likelihood ratio 0.7, and positive likelihood ratio 3.5. These are the first reported data based on more than 100 DPTs with antineoplastic and biological agents (paclitaxel, oxaliplatin, rituximab, infliximab, irinotecan, and other drugs). Implementation of DPT in diagnostic protocols helps exclude hypersensitivity (in 36% of all referred patients), and avoids unnecessary desensitizations in nonhypersensitive patients (30-56% of patients, depending on culprit-drug). Drug provocation test is vital to validate diagnostic tools; consequently, quality data are shown on oxaliplatin-specific IgE and oxaliplatin-ST in the largest series of oxaliplatin-reactive patients reported to date (74 oxaliplatin-reactive patients). Identifying phenotypes and predictors of a diagnosis of hypersensitivity may be helpful for tailored plans. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dynamical jumping real-time fault-tolerant routing protocol for wireless sensor networks.
Wu, Guowei; Lin, Chi; Xia, Feng; Yao, Lin; Zhang, He; Liu, Bing
2010-01-01
In time-critical wireless sensor network (WSN) applications, a high degree of reliability is commonly required. A dynamical jumping real-time fault-tolerant routing protocol (DMRF) is proposed in this paper. Each node utilizes the remaining transmission time of the data packets and the state of the forwarding candidate node set to dynamically choose the next hop. Once node failure, network congestion or void region occurs, the transmission mode will switch to jumping transmission mode, which can reduce the transmission time delay, guaranteeing the data packets to be sent to the destination node within the specified time limit. By using feedback mechanism, each node dynamically adjusts the jumping probabilities to increase the ratio of successful transmission. Simulation results show that DMRF can not only efficiently reduce the effects of failure nodes, congestion and void region, but also yield higher ratio of successful transmission, smaller transmission delay and reduced number of control packets.
Measuring signal-to-noise ratio in partially parallel imaging MRI
Goerner, Frank L.; Clarke, Geoffrey D.
2011-01-01
Purpose: To assess five different methods of signal-to-noise ratio (SNR) measurement for partially parallel imaging (PPI) acquisitions. Methods: Measurements were performed on a spherical phantom and three volunteers using a multichannel head coil a clinical 3T MRI system to produce echo planar, fast spin echo, gradient echo, and balanced steady state free precession image acquisitions. Two different PPI acquisitions, generalized autocalibrating partially parallel acquisition algorithm and modified sensitivity encoding with acceleration factors (R) of 2–4, were evaluated and compared to nonaccelerated acquisitions. Five standard SNR measurement techniques were investigated and Bland–Altman analysis was used to determine agreement between the various SNR methods. The estimated g-factor values, associated with each method of SNR calculation and PPI reconstruction method, were also subjected to assessments that considered the effects on SNR due to reconstruction method, phase encoding direction, and R-value. Results: Only two SNR measurement methods produced g-factors in agreement with theoretical expectations (g ≥ 1). Bland–Altman tests demonstrated that these two methods also gave the most similar results relative to the other three measurements. R-value was the only factor of the three we considered that showed significant influence on SNR changes. Conclusions: Non-signal methods used in SNR evaluation do not produce results consistent with expectations in the investigated PPI protocols. Two of the methods studied provided the most accurate and useful results. Of these two methods, it is recommended, when evaluating PPI protocols, the image subtraction method be used for SNR calculations due to its relative accuracy and ease of implementation. PMID:21978049
Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szpala, Stanislaw; Kohli, Kirpal S.
Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancymore » of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.« less
Feasibility of a Clinical Pathway with Early Oral Intake and Discharge for Laparoscopic Gastrectomy.
Nakagawa, M; Tomii, C; Inokuchi, M; Otsuki, S; Kojima, K
2017-12-01
Although some studies have reported the safety of early oral intake after gastrectomy, it still remains controversial. This study focused on the feasibility of a clinical pathway with early oral intake and discharge setting for exclusively laparoscopic distal gastrectomy. A clinical pathway was applied to 403 patients until December 2014. In the protocol, patients are allowed to take a sip of water and a soft diet on the first and second days after the operation, respectively, and the discharge day is set as the fifth to seventh day after the operation. Clinicopathological variables were prospectively collected, and risk factors for discharge variances were analyzed. The completion rate of the clinical pathway was 76.9%. There were five re-admissions (1.2%). The overall morbidity rate was 18% ( n = 72), and major complications (Clavien-Dindo IIIa or greater) occurred in 13 patients (3%). Complications were the causes for discharge variances in 68 cases (73%), while the attending surgeons' judgment was the cause in 25 cases (27%). On multivariate analysis, age (odds ratio = 2.23, 95% confidence interval = 1.38-3.60, p = 0.001) and operative time (odds ratio = 2.38, 95% confidence interval = 1.45-3.98, p = 0.001) were independent risk factors for discharge variances. A high completion rate of a clinical pathway with early oral intake and discharge setting for laparoscopic distal gastrectomy was achievable with an acceptably low re-admission rate. Laparoscopic distal gastrectomy is recommended as a first step for a clinical pathway with an early oral intake and discharge protocol.
Aissa, Joel; Boos, Johannes; Rubbert, Christian; Caspers, Julian; Schleich, Christoph; Thomas, Christoph; Kröpil, Patric; Antoch, Gerald; Miese, Falk
2017-06-01
The aim of this study was to evaluate the objective and subjective image quality of a novel computed tomography (CT) protocol with reduced radiation dose for body packing with 80 kVp and automated tube current modulation (ATCM) compared to a standard body packing CT protocol. 80 individuals who were examined between March 2012 and July 2015 in suspicion of ingested drug packets were retrospectively included in this study. Thirty-one CT examinations were performed using ATCM and a fixed tube voltage of 80 kVp (group A). Forty-nine CT examinations were performed using a standard protocol with a tube voltage of 120 kVp and a fixed tube current time product of 40 mAs (group B). Subjective and objective image quality and visibility of drug packets were assessed. Radiation exposure of both protocols was compared. Contrast-to-noise ratio (group A: 0.56 ± 0.36; group B: 1.13 ± 0.91) and Signal-to-noise ratio (group A: 3.69 ± 0.98; group B: 7.08 ± 2.67) were significantly lower for group A compared to group B (p < 0.001). Subjectively, image quality was decreased for group A compared to group B (2.5 ± 0.8 vs. 1.2 ± 0.4; p < 0.001). Attenuation of body packets was higher with the new protocol (group A: 362.2 ± 70.3 Hounsfield Units (HU); group B: 210.6 ± 60.2 HU; p = 0.005). Volumetric Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) were significantly lower in group A (CTDIvol 2.2 ± 0.9 mGy, DLP 105.7 ± 52.3 mGycm) as compared to group B (CTDIvol 2.7 ± 0.1 mGy, DLP 126.0 ± 9.7 mGycm, p = 0.002 and p = 0.01). The novel 80 kVp CT protocol with ATCM leads to a significant dose reduction compared to a standard CT body packing protocol. The novel protocol led to a diagnostic image quality and cocaine body packets were reliably detected due to the high attenuation.
Sanchez, Sophie; Fernandez, Vincent; Pierce, Stephanie E; Tafforeau, Paul
2013-09-01
Propagation phase-contrast synchrotron radiation microtomography (PPC-SRμCT) has proved to be very successful for examining fossils. Because fossils range widely in taphonomic preservation, size, shape and density, X-ray computed tomography protocols are constantly being developed and refined. Here we present a 1-h procedure that combines a filtered high-energy polychromatic beam with long-distance PPC-SRμCT (sample to detector: 4-16 m) and an attenuation protocol normalizing the absorption profile (tested on 13-cm-thick and 5.242 g cm(-3) locally dense samples but applicable to 20-cm-thick samples). This approach provides high-quality imaging results, which show marked improvement relative to results from images obtained without the attenuation protocol in apparent transmission, contrast and signal-to-noise ratio. The attenuation protocol involves immersing samples in a tube filled with aluminum or glass balls in association with a U-shaped aluminum profiler. This technique therefore provides access to a larger dynamic range of the detector used for tomographic reconstruction. This protocol homogenizes beam-hardening artifacts, thereby rendering it effective for use with conventional μCT scanners.
A Novel Cross-Layer Routing Protocol Based on Network Coding for Underwater Sensor Networks.
Wang, Hao; Wang, Shilian; Bu, Renfei; Zhang, Eryang
2017-08-08
Underwater wireless sensor networks (UWSNs) have attracted increasing attention in recent years because of their numerous applications in ocean monitoring, resource discovery and tactical surveillance. However, the design of reliable and efficient transmission and routing protocols is a challenge due to the low acoustic propagation speed and complex channel environment in UWSNs. In this paper, we propose a novel cross-layer routing protocol based on network coding (NCRP) for UWSNs, which utilizes network coding and cross-layer design to greedily forward data packets to sink nodes efficiently. The proposed NCRP takes full advantages of multicast transmission and decode packets jointly with encoded packets received from multiple potential nodes in the entire network. The transmission power is optimized in our design to extend the life cycle of the network. Moreover, we design a real-time routing maintenance protocol to update the route when detecting inefficient relay nodes. Substantial simulations in underwater environment by Network Simulator 3 (NS-3) show that NCRP significantly improves the network performance in terms of energy consumption, end-to-end delay and packet delivery ratio compared with other routing protocols for UWSNs.
Kylander, M E; Weiss, D J; Jeffries, T E; Kober, B; Dolgopolova, A; Garcia-Sanchez, R; Coles, B J
2007-01-16
An analytical protocol for rapid and reliable laser ablation-quadrupole (LA-Q)- and multi-collector (MC-) inductively coupled plasma-mass spectrometry (ICP-MS) analysis of Pb isotope ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb) in peats and lichens is developed. This technique is applicable to source tracing atmospheric Pb deposition in biomonitoring studies and sample screening. Reference materials and environmental samples were dry ashed and pressed into pellets for introduction by laser ablation. No binder was used to reduce contamination. LA-MC-ICP-MS internal and external precisions were <1.1% and <0.3%, respectively, on both (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios. LA-Q-ICP-MS internal precisions on (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios were lower with values for the different sample sets <14.3% while external precisions were <2.9%. The level of external precision acquired in this study is high enough to distinguish between most modern Pb sources. LA-MC-ICP-MS measurements differed from thermal ionisation mass spectrometry (TIMS) values by 1% or less while the accuracy obtained using LA-Q-ICP-MS compared to solution MC-ICP-MS was 3.1% or better using a run bracketing (RB) mass bias correction method. Sample heterogeneity and detector switching when measuring (208)Pb by Q-ICP-MS are identified as sources of reduced analytical performance.
Yigzaw, Kassaye Yitbarek; Michalas, Antonis; Bellika, Johan Gustav
2017-01-03
Techniques have been developed to compute statistics on distributed datasets without revealing private information except the statistical results. However, duplicate records in a distributed dataset may lead to incorrect statistical results. Therefore, to increase the accuracy of the statistical analysis of a distributed dataset, secure deduplication is an important preprocessing step. We designed a secure protocol for the deduplication of horizontally partitioned datasets with deterministic record linkage algorithms. We provided a formal security analysis of the protocol in the presence of semi-honest adversaries. The protocol was implemented and deployed across three microbiology laboratories located in Norway, and we ran experiments on the datasets in which the number of records for each laboratory varied. Experiments were also performed on simulated microbiology datasets and data custodians connected through a local area network. The security analysis demonstrated that the protocol protects the privacy of individuals and data custodians under a semi-honest adversarial model. More precisely, the protocol remains secure with the collusion of up to N - 2 corrupt data custodians. The total runtime for the protocol scales linearly with the addition of data custodians and records. One million simulated records distributed across 20 data custodians were deduplicated within 45 s. The experimental results showed that the protocol is more efficient and scalable than previous protocols for the same problem. The proposed deduplication protocol is efficient and scalable for practical uses while protecting the privacy of patients and data custodians.
NASA Astrophysics Data System (ADS)
Jiang, Yang; Gong, Yuanzheng; Wang, Thomas D.; Seibel, Eric J.
2017-02-01
Multimodal endoscopy, with fluorescence-labeled probes binding to overexpressed molecular targets, is a promising technology to visualize early-stage cancer. T/B ratio is the quantitative analysis used to correlate fluorescence regions to cancer. Currently, T/B ratio calculation is post-processing and does not provide real-time feedback to the endoscopist. To achieve real-time computer assisted diagnosis (CAD), we establish image processing protocols for calculating T/B ratio and locating high-risk fluorescence regions for guiding biopsy and therapy in Barrett's esophagus (BE) patients. Methods: Chan-Vese algorithm, an active contour model, is used to segment high-risk regions in fluorescence videos. A semi-implicit gradient descent method was applied to minimize the energy function of this algorithm and evolve the segmentation. The surrounding background was then identified using morphology operation. The average T/B ratio was computed and regions of interest were highlighted based on user-selected thresholding. Evaluation was conducted on 50 fluorescence videos acquired from clinical video recordings using a custom multimodal endoscope. Results: With a processing speed of 2 fps on a laptop computer, we obtained accurate segmentation of high-risk regions examined by experts. For each case, the clinical user could optimize target boundary by changing the penalty on area inside the contour. Conclusion: Automatic and real-time procedure of calculating T/B ratio and identifying high-risk regions of early esophageal cancer was developed. Future work will increase processing speed to <5 fps, refine the clinical interface, and apply to additional GI cancers and fluorescence peptides.
Qu, Shu-Gen; Gao, Jin; Tang, Bo; Yu, Bo; Shen, Yue-Ping; Tu, Yu
2018-01-01
Low-dose ionizing radiation (LDIR) may increase the mortality of solid cancers in nuclear industry workers, but only few individual cohort studies exist, and the available reports have low statistical power. The aim of the present study was to focus on solid cancer mortality risk from LDIR in the nuclear industry using standard mortality ratios (SMRs) and 95% confidence intervals. A systematic literature search through the PubMed and Embase databases identified 27 studies relevant to this meta-analysis. There was statistical significance for total, solid and lung cancers, with meta-SMR values of 0.88, 0.80, and 0.89, respectively. There was evidence of stochastic effects by IR, but more definitive conclusions require additional analyses using standardized protocols to determine whether LDIR increases the risk of solid cancer-related mortality. PMID:29725540
Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Revised
NASA Technical Reports Server (NTRS)
Fargion, Giulietta S.; Mueller, James L.
2000-01-01
The document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. This document supersedes the earlier version (Mueller and Austin 1995) published as Volume 25 in the SeaWiFS Technical Report Series. This document marks a significant departure from, and improvement on, theformat and content of Mueller and Austin (1995). The authorship of the protocols has been greatly broadened to include experts specializing in some key areas. New chapters have been added to provide detailed and comprehensive protocols for stability monitoring of radiometers using portable sources, abovewater measurements of remote-sensing reflectance, spectral absorption measurements for discrete water samples, HPLC pigment analysis and fluorometric pigment analysis. Protocols were included in Mueller and Austin (1995) for each of these areas, but the new treatment makes significant advances in each topic area. There are also new chapters prescribing protocols for calibration of sun photometers and sky radiance sensors, sun photometer and sky radiance measurements and analysis, and data archival. These topic areas were barely mentioned in Mueller and Austin (1995).
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).
Rummel, John D; Kminek, Gerhard
2018-04-01
The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.
Barbanti, A.; Bothner, Michael H.
1993-01-01
A method to separate sediments into discrete size fractions for geochemical analysis has been tested. The procedures were chosen to minimize the destruction or formation of aggregates and involved gentle sieving and settling of wet samples. Freeze-drying and sonication pretreatments, known to influence aggregates, were used for comparison. Freeze-drying was found to increase the silt/clay ratio by an average of 180 percent compared to analysis of a wet sample that had been wet sieved only. Sonication of a wet sample decreased the silt/clay ratio by 51 percent. The concentrations of metals and organic carbon in the separated fractions changed depending on the pretreatment procedures in a manner consistent with the hypothesis that aggregates consist of fine-grained organic- and metal-rich particles. The coarse silt fraction of a freeze-dried sample contained 20–44 percent higher concentrations of Zn, Cu, and organic carbon than the coarse silt fraction of the wet sample. Sonication resulted in concentrations of these analytes that were 18–33 percent lower in the coarse silt fraction than found in the wet sample. Sonication increased the concentration of lead in the clay fraction by an average of 40 percent compared to an unsonicated sample. Understanding the magnitude of change caused by different analysis protocols is an aid in designing future studies that seek to interpret the spatial distribution of contaminated sediments and their transport mechanisms.
Analysis of possible factors of vocal interference during the teaching activity
Silva, Bárbara Gabriela; Chammas, Tiago Visacre; Zenari, Marcia Simões; Moreira, Renata Rodrigues; Samelli, Alessandra Giannella; Nemr, Kátia
2017-01-01
ABSTRACT OBJECTIVE To measure the risk of dysphonia in teachers, as well as investigate whether the perceptual-auditory and acoustic aspects of the voice of teachers in situations of silence and noise, the signal-to-noise ratio, and the noise levels in the classroom are associated with the presence of dysphonia. METHODS This is an observational cross-sectional research with 23 primary and secondary school teachers from a private school in the municipality of São Paulo, Brazil, divided into the groups without dysphonia and with dysphonia. We performed the following procedures: general Dysphonia Risk Screening Protocol (General-DRSP) and complementary to speaking voice - teacher (Specific-DRSP), voice recording during class and in an individual situation in a silent room, and measurement of the signal-to-noise ratio and noise levels of classrooms. RESULTS We have found differences between groups regarding physical activity (General-DRSP) and particularities of the profession (Specific-DRSP), as well as in all aspects of the perceptual-auditory vocal analysis. We have found signs of voice wear in the group without dysphonia. Regarding the vocal resources in the situations of noise and silence, we have identified a difference for the production of abrupt vocal attack and the tendency of a more precise speech in the situation of noise. Both the signal-to-noise ratio and the room noise levels during class were high in both groups. CONCLUSIONS Teachers in both groups are at high risk for developing dysphonia and have negative vocal signals to a greater or lesser extent. Signal-to-noise ratio was inadequate in most classrooms, considering the standards for both children with normal hearing and with hearing loss, as well as equivalent noise levels. PMID:29236878
Tanner, Julie-Anne; Novalen, Maria; Jatlow, Peter; Huestis, Marilyn A.; Murphy, Sharon E.; Kaprio, Jaakko; Kankaanpää, Aino; Galanti, Laurence; Stefan, Cristiana; George, Tony P.; Benowitz, Neal L.; Lerman, Caryn; Tyndale, Rachel F.
2015-01-01
Background The highly genetically variable enzyme CYP2A6 metabolizes nicotine to cotinine (COT) and COT to trans-3′-hydroxycotinine (3HC). The nicotine metabolite ratio (NMR, 3HC/COT) is commonly used as a biomarker of CYP2A6 enzymatic activity, rate of nicotine metabolism, and total nicotine clearance; NMR is associated with numerous smoking phenotypes, including smoking cessation. Our objective was to investigate the impact of different measurement methods, at different sites, on plasma and urinary NMR measures from ad libitum smokers. Methods Plasma (n=35) and urine (n=35) samples were sent to eight different laboratories, which employed similar and different methods of COT and 3HC measurements to derive the NMR. We used Bland-Altman analysis to assess agreement, and Pearson correlations to evaluate associations, between NMR measured by different methods. Results Measures of plasma NMR were in strong agreement between methods according to Bland-Altman analysis (ratios 0.82–1.16) and were highly correlated (all Pearson r>0.96, P<0.0001). Measures of urinary NMR were in relatively weaker agreement (ratios 0.62–1.71) and less strongly correlated (Pearson r values of 0.66–0.98, P<0.0001) between different methods. Plasma and urinary COT and 3HC concentrations, while weaker than NMR, also showed good agreement in plasma, which was better than in urine, as was observed for NMR. Conclusions Plasma is a very reliable biological source for the determination of NMR, robust to differences in these analytical protocols or assessment site. Impact Together this indicates a reduced need for differential interpretation of plasma NMR results based on the approach used, allowing for direct comparison of different studies. PMID:26014804
Analysis of possible factors of vocal interference during the teaching activity.
Silva, Bárbara Gabriela; Chammas, Tiago Visacre; Zenari, Marcia Simões; Moreira, Renata Rodrigues; Samelli, Alessandra Giannella; Nemr, Kátia
2017-12-11
To measure the risk of dysphonia in teachers, as well as investigate whether the perceptual-auditory and acoustic aspects of the voice of teachers in situations of silence and noise, the signal-to-noise ratio, and the noise levels in the classroom are associated with the presence of dysphonia. This is an observational cross-sectional research with 23 primary and secondary school teachers from a private school in the municipality of São Paulo, Brazil, divided into the groups without dysphonia and with dysphonia. We performed the following procedures: general Dysphonia Risk Screening Protocol (General-DRSP) and complementary to speaking voice - teacher (Specific-DRSP), voice recording during class and in an individual situation in a silent room, and measurement of the signal-to-noise ratio and noise levels of classrooms. We have found differences between groups regarding physical activity (General-DRSP) and particularities of the profession (Specific-DRSP), as well as in all aspects of the perceptual-auditory vocal analysis. We have found signs of voice wear in the group without dysphonia. Regarding the vocal resources in the situations of noise and silence, we have identified a difference for the production of abrupt vocal attack and the tendency of a more precise speech in the situation of noise. Both the signal-to-noise ratio and the room noise levels during class were high in both groups. Teachers in both groups are at high risk for developing dysphonia and have negative vocal signals to a greater or lesser extent. Signal-to-noise ratio was inadequate in most classrooms, considering the standards for both children with normal hearing and with hearing loss, as well as equivalent noise levels.
NASA Astrophysics Data System (ADS)
Bocsi, Jozsef; Mittag, Anja; Varga, Viktor S.; Molnar, Bela; Tulassay, Zsolt; Sack, Ulrich; Lenz, Dominik; Tarnok, Attila
2006-02-01
Scanning Fluorescence Microscope (SFM) is a new technique for automated motorized microscopes to measure multiple fluorochrome labeled cells (Bocsi et al. Cytometry 2004, 61A:1). The ratio of CD4+/CD8+ cells is an important in immune diagnostics in immunodeficiency and HIV. Therefor a four-color staining protocol (DNA, CD3, CD4 and CD8) for automated SFM analysis of lymphocytes was developed. EDTA uncoagulated blood was stained with organic and inorganic (Quantum dots) fluorochromes in different combinations. Aliquots of samples were measured by Flow Cytometry (FCM) and SFM. By SFM specimens were scanned and digitized using four fluorescence filter sets. Automated cell detection (based on Hoechst 33342 fluorescence), CD3, CD4 and CD8 detection were performed, CD4/CD8 ratio was calculated. Fluorescence signals were well separable on SFM and FCM. Passing and Bablok regression of all CD4/CD8 ratios obtained by FCM and SFM (F(X)=0.0577+0.9378x) are in the 95% confidence interval. Cusum test did not show significant deviation from linearity (P>0.10). This comparison indicates that there is no systemic bias between the two different methods. In SFM analyses the inorganic Quantum dot staining was very stable in PBS in contrast to the organic fluorescent dyes, but bleached shortly after mounting with antioxidant and free radical scavenger mounting media. This shows the difficulty of combinations of organic dyes and Quantum dots. Slide based multi-fluorescence labeling system and automated SFM are applicable tools for the CD4/CD8 ratio determination in peripheral blood samples. Quantum Dots are stable inorganic fluorescence labels that may be used as reliable high resolution dyes for cell labeling.
METHODS AND ANALYSES FOR IMPLEMENTING NATURAL ATTENUATION PROTOCOLS
Technical protocols for evaluating natural attenuation at petroleum hydrocarbon and chlorinated solvent contaminated sites specify the analysis of electron acceptors and metabolic by-products for identifying and quantifying natural attenuation processes. However, these protocols ...
Cirrus: Inducing Subject Models from Protocol Data
1988-08-16
Protocol analysis is used routinely by psychologists and other behavior scientists, and more recently, by knowledge engineers who wish to embed the...knowledge of human experts in an expert system. However, protocol analysis is notoriously difficult and time comsuming . Several systems have been developed to...formal trace of it (a problem behavior graph). The system, however, did not produce an abstract model of the subject. Bhaskar and Simon (1977) avoided the
IRB Process Improvements: A Machine Learning Analysis.
Shoenbill, Kimberly; Song, Yiqiang; Cobb, Nichelle L; Drezner, Marc K; Mendonca, Eneida A
2017-06-01
Clinical research involving humans is critically important, but it is a lengthy and expensive process. Most studies require institutional review board (IRB) approval. Our objective is to identify predictors of delays or accelerations in the IRB review process and apply this knowledge to inform process change in an effort to improve IRB efficiency, transparency, consistency and communication. We analyzed timelines of protocol submissions to determine protocol or IRB characteristics associated with different processing times. Our evaluation included single variable analysis to identify significant predictors of IRB processing time and machine learning methods to predict processing times through the IRB review system. Based on initial identified predictors, changes to IRB workflow and staffing procedures were instituted and we repeated our analysis. Our analysis identified several predictors of delays in the IRB review process including type of IRB review to be conducted, whether a protocol falls under Veteran's Administration purview and specific staff in charge of a protocol's review. We have identified several predictors of delays in IRB protocol review processing times using statistical and machine learning methods. Application of this knowledge to process improvement efforts in two IRBs has led to increased efficiency in protocol review. The workflow and system enhancements that are being made support our four-part goal of improving IRB efficiency, consistency, transparency, and communication.
A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.
Mehmood, Zahid; Chen, Gongliang; Li, Jianhua; Li, Linsen; Alzahrani, Bander
2017-01-01
Over the past few years, Session Initiation Protocol (SIP) is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.
Laffey, Ann O; Krigbaum, John; Zimmerman, Andrew R
2017-02-15
Bone lipid compound-specific isotope analysis (CSIA) and bone collagen and apatite stable isotope ratio analysis are important sources of ecological and paleodietary information. Pressurized liquid extraction (PLE) is quicker and utilizes less solvent than traditional methods of lipid extraction such as soxhlet and ultrasonication. This study facilitates dietary analysis by optimizing and testing a standardized methodology for PLE of bone cholesterol. Modern and archaeological bones were extracted by PLE using varied temperatures, solvent solutions, and sample weights. The efficiency of PLE was assessed via quantification of cholesterol yields. Stable isotopic ratio integrity was evaluated by comparing isotopic signatures (δ 13 C and δ 18 O values) of cholesterol derived from whole bone, bone collagen and bone apatite. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography isotope ratio mass spectrometry (GC/IRMS) were conducted on purified collagen and lipid extracts to assess isotopic responses to PLE. Lipid yield was optimized at two PLE extraction cycles of 75 °C using dichloromethane/methanol (2:1 v/v) as a solvent with 0.25-0.75 g bone sample. Following lipid extraction, saponification combined with the derivatization of the neutral fraction using trimethylsilylation yielded nearly twice the cholesterol of non-saponified or non-derivatized samples. It was also found that lipids extracted from purified bone collagen and apatite could be used for cholesterol CSIA. There was no difference in the bulk δ 13 C values of collagen extracted from bone with or without lipid. However, there was a significant depletion in 18 O of bone apatite due to lipid presence or processing. These results should assist sample selection and provide an effective, alternative extraction method for bone cholesterol that may be used for isotopic and paleodietary analysis. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Measuring Audience Engagement for Public Health Twitter Chats: Insights From #LiveFitNOLA.
Rabarison, Kristina M; Croston, Merriah A; Englar, Naomi K; Bish, Connie L; Flynn, Shelbi M; Johnson, Carolyn C
2017-06-08
Little empirical evidence exists on the effectiveness of using Twitter as a two-way communication tool for public health practice, such as Twitter chats. We analyzed whether Twitter chats facilitate engagement in two-way communications between public health entities and their audience. We also describe how to measure two-way communications, incoming and outgoing mentions, between users in a protocol using free and publicly available tools (Symplur, OpenRefine, and Gephi). We used a mixed-methods approach, social network analysis, and content analysis. The study population comprised individuals and organizations participating or who were mentioned in the first #LiveFitNOLA chat, during a 75-min period on March 5, 2015, from 12:00 PM to 1:15 PM Central Time. We assessed audience engagement in two-way communications with two metrics: engagement ratio and return on engagement (ROE). The #LiveFitNOLA chat had 744 tweets and 66 participants with an average of 11 tweets per participant. The resulting network had 134 network members and 474 engagements. The engagement ratios and ROEs for the #LiveFitNOLA organizers were 1:1, 40% (13/32) (@TulanePRC) and 2:1, -40% (-25/63) (@FitNOLA). Content analysis showed information sharing (63.9%, 314/491) and health information (27.9%, 137/491) as the most salient theme and sub-theme, respectively. Our findings suggest Twitter chats facilitate audience engagement in two-way communications between public health entities and their audience. The #LiveFitNOLA organizers' engagement ratios and ROEs indicated a moderate level of engagement with their audience. The practical significance of the engagement ratio and ROE depends on the audience, context, scope, scale, and goal of a Twitter chat or other organized hashtag-based communications on Twitter. ©Kristina M Rabarison, Merriah A Croston, Naomi K Englar, Connie L Bish, Shelbi M Flynn, Carolyn C Johnson. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 08.06.2017.
Mishra, Nibha; Saxena, Sandeep; Ruia, Surabhi; Prasad, Senthamizh; Singh, Vinita; Khanna, Vinay; Staffa, Robert; Gaspar, Ludovit; Kruzliak, Peter
2016-07-01
To evaluate the association of serum levels of N(ε)- Carboxy methyl lysine (N(ε)-CML), an advanced glycation end product with topographic alterations in retinal pigment epithelium (RPE) in diabetic retinopathy on spectral domain optical coherence tomography (SD-OCT). Consecutive cases of type 2 diabetes mellitus with no retinopathy (n=20); non-proliferative diabetic retinopathy (n=20); proliferative diabetic retinopathy (n=20) and healthy controls (n=20) between the ages of 40 and 65years were included. RPE alterations were graded on segmentation map of SD-OCT: grade 0, No RPE alterations; grade 1, RPE alterations in up to two quadrants and grade 2, RPE alterations in more than two quadrants. Serum level of N(ε)-CML and glycated hemoglobin (HbA1c) was analyzed using the standard protocol. Statistical analysis was done. Significant increase in N(ε)-CML was observed with increased severity of diabetic retinopathy (F=34.1; p<0.0001). Fisher exact test revealed significant increase in grades of RPE alterations with increased severity of diabetic retinopathy (p<0.001). Univariate ordinal regression analysis was done to calculate the risk of progression in grades of RPE alteration with individual changes in variables like duration of diabetes (odds ratio=1.37; p=0.001), HbA1c (odds ratio=1.37; p=0.002) and Nε-CML (odds ratio=1.37; p<0.0001). Multivariate ordinal regression analysis for predicting progression in grades of RPE alteration revealed Nε-CML to be an independent predictor of increase in grades of RPE alteration (adjusted odds ratio=1.07; p<0.01) when duration of diabetes and HbA1c were held constant. Increase in serum levels of N(ε)- Carboxy methyl lysine is significantly associated with topographic alterations in RPE. Grades of RPE alteration increase significantly with increased severity of diabetic retinopathy. Copyright © 2016 Elsevier Inc. All rights reserved.
Campoy, Irene; Lanau, Lucia; Altadill, Tatiana; Sequeiros, Tamara; Cabrera, Silvia; Cubo-Abert, Montserrat; Pérez-Benavente, Assumpción; Garcia, Angel; Borrós, Salvador; Santamaria, Anna; Ponce, Jordi; Matias-Guiu, Xavier; Reventós, Jaume; Gil-Moreno, Antonio; Rigau, Marina; Colas, Eva
2016-06-18
Uterine aspirates are used in the diagnostic process of endometrial disorders, yet further applications could emerge if its complex milieu was simplified. Exosome-like vesicles isolated from uterine aspirates could become an attractive source of biomarkers, but there is a need to standardize isolation protocols. The objective of the study was to determine whether exosome-like vesicles exist in the fluid fraction of uterine aspirates and to compare protocols for their isolation, characterization, and analysis. We collected uterine aspirates from 39 pre-menopausal women suffering from benign gynecological diseases. The fluid fraction of 27 of those aspirates were pooled and split into equal volumes to evaluate three differential centrifugation-based procedures: (1) a standard protocol, (2) a filtration protocol, and (3) a sucrose cushion protocol. Characterization of isolated vesicles was assessed by electron microscopy, nanoparticle tracking analysis and immunoblot. Specifically for RNA material, we evaluate the effect of sonication and RNase A treatment at different steps of the protocol. We finally confirmed the efficiency of the selected methods in non-pooled samples. All protocols were useful to isolate exosome-like vesicles. However, the Standard procedure was the best performing protocol to isolate exosome-like vesicles from uterine aspirates: nanoparticle tracking analysis revealed a higher concentration of vesicles with a mode of 135 ± 5 nm, and immunoblot showed a higher expression of exosome-related markers (CD9, CD63, and CD81) thus verifying an enrichment in this type of vesicles. RNA contained in exosome-like vesicles was successfully extracted with no sonication treatment and exogenous nucleic acids digestion with RNaseA, allowing the analysis of the specific inner cargo by Real-Time qPCR. We confirmed the existence of exosome-like vesicles in the fluid fraction of uterine aspirates. They were successfully isolated by differential centrifugation giving sufficient proteomic and transcriptomic material for further analyses. The Standard protocol was the best performing procedure since the other two tested protocols did not ameliorate neither yield nor purity of exosome-like vesicles. This study contributes to establishing the basis for future comparative studies to foster the field of biomarker research in gynecology.
Clock Scan Protocol for Image Analysis: ImageJ Plugins.
Dobretsov, Maxim; Petkau, Georg; Hayar, Abdallah; Petkau, Eugen
2017-06-19
The clock scan protocol for image analysis is an efficient tool to quantify the average pixel intensity within, at the border, and outside (background) a closed or segmented convex-shaped region of interest, leading to the generation of an averaged integral radial pixel-intensity profile. This protocol was originally developed in 2006, as a visual basic 6 script, but as such, it had limited distribution. To address this problem and to join similar recent efforts by others, we converted the original clock scan protocol code into two Java-based plugins compatible with NIH-sponsored and freely available image analysis programs like ImageJ or Fiji ImageJ. Furthermore, these plugins have several new functions, further expanding the range of capabilities of the original protocol, such as analysis of multiple regions of interest and image stacks. The latter feature of the program is especially useful in applications in which it is important to determine changes related to time and location. Thus, the clock scan analysis of stacks of biological images may potentially be applied to spreading of Na + or Ca ++ within a single cell, as well as to the analysis of spreading activity (e.g., Ca ++ waves) in populations of synaptically-connected or gap junction-coupled cells. Here, we describe these new clock scan plugins and show some examples of their applications in image analysis.
Wade, Darryl; Varker, Tracey; Forbes, David; O'Donnell, Meaghan
2014-01-01
The Alcohol Use Disorders Identification Test-Consumption (AUDIT-C) is a brief alcohol screening test and a candidate for inclusion in recommended screening and brief intervention protocols for acute injury patients. The objective of the current study was to examine the performance of the AUDIT-C to risk stratify injury patients with regard to their probability of having an alcohol use disorder. Participants (n = 1,004) were from a multisite Australian acute injury study. Stratum-specific likelihood ratio (SSLR) analysis was used to examine the performance of previously recommended AUDIT-C risk zones based on a dichotomous cut-point (0 to 3, 4 to 12) and risk zones derived from SSLR analysis to estimate the probability of a current alcohol use disorder. Almost a quarter (23%) of patients met criteria for a current alcohol use disorder. SSLR analysis identified multiple AUDIT-C risk zones (0 to 3, 4 to 5, 6, 7 to 8, 9 to 12) with a wide range of posttest probabilities of alcohol use disorder, from 5 to 68%. The area under receiver operating characteristic curve (AUROC) score was 0.82 for the derived AUDIT-C zones and 0.70 for the recommended AUDIT-C zones. A comparison between AUROCs revealed that overall the derived zones performed significantly better than the recommended zones in being able to discriminate between patients with and without alcohol use disorder. The findings of SSLR analysis can be used to improve estimates of the probability of alcohol use disorder in acute injury patients based on AUDIT-C scores. In turn, this information can inform clinical interventions and the development of screening and intervention protocols in a range of settings. Copyright © 2013 by the Research Society on Alcoholism.
Watanabe, Tsubasa; Hattori, Yoshihide; Ohta, Youichiro; Ishimura, Miki; Nakagawa, Yosuke; Sanada, Yu; Tanaka, Hiroki; Fukutani, Satoshi; Masunaga, Shin-Ichiro; Hiraoka, Masahiro; Ono, Koji; Suzuki, Minoru; Kirihata, Mitsunori
2016-11-08
Boron neutron capture therapy (BNCT) is a cellular-level particle radiation therapy that combines the selective delivery of boron compounds to tumour tissue with neutron irradiation. L-p-Boronophenylalanine (L-BPA) is a boron compound now widely used in clinical situations. Determination of the boron distribution is required for successful BNCT prior to neutron irradiation. Thus, positron emission tomography with [ 18 F]-L-FBPA, an 18 F-labelled radiopharmaceutical analogue of L-BPA, was developed. However, several differences between L-BPA and [ 18 F]-L-FBPA have been highlighted, including the different injection doses and administration protocols. The purpose of this study was to clarify the equivalence between L-BPA and [ 19 F]-L-FBPA as alternatives to [ 18 F]-L-FBPA. SCC-VII was subcutaneously inoculated into the legs of C3H/He mice. The same dose of L-BPA or [ 19 F]-L-FBPA was subcutaneously injected. The time courses of the boron concentrations in blood, tumour tissue, and normal tissue were compared between the groups. Next, we administered the therapeutic dose of L-BPA or the same dose of [ 19 F]-L-FBPA by continuous infusion and compared the effects of the administration protocol on boron accumulation in tissues. There were no differences between L-BPA and [ 19 F]-L-FBPA in the transition of boron concentrations in blood, tumour tissue, and normal tissue using the same administration protocol. However, the normal tissue to blood ratio of the boron concentrations in the continuous-infusion group was lower than that in the subcutaneous injection group. No difference was noted in the time course of the boron concentrations in tumour tissue and normal tissues between L-BPA and [ 19 F]-L-FBPA. However, the administration protocol had effects on the normal tissue to blood ratio of the boron concentration. In estimating the BNCT dose in normal tissue by positron emission tomography (PET), we should consider the possible overestimation of the normal tissue to blood ratio of the boron concentrations derived from the values measured by PET on dose calculation.
Eschner, Andrew K; Mugnai, Kristen
2015-02-10
In North America, Borrelia burgdorferi is the causative bacterial agent of canine Lyme borreliosis and is transmitted following prolonged attachment and feeding of vector ticks, Ixodes scapularis or Ixodes pacificus. Its prevention is predicated upon tick-avoidance, effective on-animal tick control and effective immunization strategies. The purpose of this study is to characterize dogs that are newly seropositive for Borrelia burgdorferi infection in relation to compliant use of a recombinant OspA canine Lyme borreliosis vaccine. Specifically, Preventive Fractions (PF) and Risk Ratios (RR) associated with the degree of vaccine compliancy (complete versus incomplete) are determined. 6,202 dogs were tested over a five year period in a single veterinary hospital utilizing a non-adjuvanted, recombinant OspA vaccine according to a 0, 1, 6 month (then yearly) protocol. Rates of newly acquired "Lyme-positive" antibody test results were compared between protocol compliant and poorly compliant (incompletely and/or non-vaccinated) dogs. Over the five-year span, one percent (range 0.39 - 1.3) of protocol compliant vaccinated, previously antibody negative dogs became seropositive for infection. Approximately twenty-one percent (range 16.8 - 33.3) of incompletely vaccinated dogs became positive for infection-specific antibodies. The Preventative Fraction for testing positive for antibodies specific for infection with Borrelia burgdorferi in any given year based on optimal vaccine compliance was, on average, 95.3% (range 93.29 - 98.08). The Risk Ratio for becoming infected with Borrelia burgdorferi antibodies in any given year if vaccine non-compliant was 21.41 (range 14.9 - 52.1). There was a high statistically significant relationship (p = <0.0001) in the observed data in terms of vaccination protocol compliance and the probability of Borrelia burgdorferi infection in each of the five years under study. The recombinant outer surface protein A (rOspA) vaccine for dogs is highly effective in preventing new seropositive cases of Borrelia burgdoferi infection over a five-year period in dogs living in an endemic area. Dogs that were vaccine protocol-compliant were significantly less likely to become infected (as indirectly assessed by antibody) with the agent of canine Lyme borreliosis as measured by Preventive Fraction and Risk Ratio calculations.
Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang
2017-01-01
To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.
Sun, Changling; Han, Xue; Li, Xiaoying; Zhang, Yayun; Du, Xiaodong
2017-04-01
Objective To evaluate the performance of narrow band imaging (NBI) for the diagnosis of laryngeal cancer and to compare the diagnostic value of NBI with that of white light endoscopy. Data Sources PubMed, Embase, Cochrane Library, and CNKI databases. Review Methods Data analyses were performed with Meta-DiSc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with the Deeks's asymmetry test. The protocol used in this article has been published on PROSPERO and is in accordance with the PRISMA checklist. The registry number for this study is CRD42015025866. Results Six studies including 716 lesions were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio for the NBI diagnosis of laryngeal cancer were 0.94 (95% confidence interval [95% CI]: 0.91-0.96), 0.89 (95% CI: 0.85-0.92), and 142.12 (95% CI: 46.42-435.15), respectively, and the area under receiver operating characteristics curve was 0.97. Among the 6 studies, 3 evaluated the diagnostic value of white light endoscopy, with a sensitivity of 0.81 (95% CI: 0.76-0.86), a specificity of 0.92 (95% CI: 0.88-0.95), and a diagnostic odds ratio of 33.82 (95% CI: 14.76-77.49). The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 66%. No marked publication bias ( P = .84) was detected in this meta-analysis. Conclusion The sensitivity of NBI is superior to white light endoscopy, and the potential value of NBI needs to be validated in future studies.
Hamon, Martial; Coste, Pierre; Van't Hof, Arnoud; Ten Berg, Jurrien; Clemmensen, Peter; Tabone, Xavier; Benamer, Hakim; Kristensen, Steen D; Cavallini, Claudio; Marzocchi, Antonio; Hamm, Christian; Kanic, Vojko; Bernstein, Debra; Anthopoulos, Prodromos; Deliargyris, Efthymios N; Steg, Philippe Gabriel
2015-06-01
In European Ambulance Acute Coronary Syndrome Angiography (EUROMAX), bivalirudin improved 30-day clinical outcomes with reduced major bleeding compared with heparins plus optional glycoprotein IIb/IIIa inhibitors. We assessed whether choice of access site (radial or femoral) had an impact on 30-day outcomes and whether it interacted with the benefit of bivalirudin. In EUROMAX, choice of arterial access was left to operator discretion. Overall, 47% of patients underwent radial and 53% femoral access. Baseline risk was higher in the femoral access group. Unadjusted proportions for the primary outcome (death or noncoronary artery bypass graft protocol major bleeding at 30 days) were lower with radial access, however, without differences in major or major plus minor bleeding proportions. After multivariable adjustment, ischemic outcomes were no longer different between access site groups, except for a lower risk of stroke in radial patients. Bivalirudin was associated with lower proportions of the primary outcome in both the radial (odds ratio, 0.58; 95% CI, 0.33-1.03; P=0.058) and the femoral groups (odds ratio, 0.59; 95% CI, 0.37-0.93; P=0.022; interaction P=0.97). Bleeding was significantly lower in the bivalirudin group both in the radial- and femoral-treated patients but no significant difference was observed in ischemic outcomes. In multivariable analysis, bivalirudin emerged as the only independent predictor of reduced major bleeding (odds ratio, 0.45; 95% CI, 0.27-0.74; P=0.002). In this prespecified analysis from EUROMAX, radial access was preferred in lower risk patients and did not improve clinical outcomes. Bivalirudin was associated with less bleeding irrespective of access site. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01087723. © 2015 American Heart Association, Inc.
Wörmer, Lars; Elvert, Marcus; Fuchser, Jens; Lipp, Julius Sebastian; Buttigieg, Pier Luigi; Zabel, Matthias; Hinrichs, Kai-Uwe
2014-01-01
Marine microorganisms adapt to their habitat by structural modification of their membrane lipids. This concept is the basis of numerous molecular proxies used for paleoenvironmental reconstruction. Archaeal tetraether lipids from ubiquitous marine planktonic archaea are particularly abundant, well preserved in the sedimentary record and used in several molecular proxies. We here introduce the direct, extraction-free analysis of these compounds in intact sediment core sections using laser desorption ionization (LDI) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). LDI FTICR-MS can detect the target lipids in single submillimeter-sized spots on sediment sections, equivalent to a sample mass in the nanogram range, and could thus pave the way for biomarker-based reconstruction of past environments and ecosystems at subannual to decadal resolution. We demonstrate that ratios of selected archaeal tetraethers acquired by LDI FTICR-MS are highly correlated with values obtained by conventional liquid chromatography/MS protocols. The ratio of the major archaeal lipids, caldarchaeol and crenarchaeol, analyzed in a 6.2-cm intact section of Mediterranean sapropel S1 at 250-µm resolution (∼4-y temporal resolution), provides an unprecedented view of the fine-scale patchiness of sedimentary biomarker distributions and the processes involved in proxy signal formation. Temporal variations of this lipid ratio indicate a strong influence of the ∼200-y de Vries solar cycle on reconstructed sea surface temperatures with possible amplitudes of several degrees, and suggest signal amplification by a complex interplay of ecological and environmental factors. Laser-based biomarker analysis of geological samples has the potential to revolutionize molecular stratigraphic studies of paleoenvironments. PMID:25331871
Bahm, Sarah M; Karkazis, Katrina; Magnus, David
2013-09-01
To identify and analyze existing posthumous sperm procurement (PSP) protocols in order to outline central themes for institutions to consider when developing future policies. Qualitative content analysis. Large academic institutions across the United States. We performed a literature search and contacted 40 institutions to obtain nine full PSP protocols. We then performed a content analysis on these policies to identify major themes and factors to consider when developing a PSP protocol. Presence of a PSP policy. We identified six components of a thorough PSP protocol: Standard of Evidence, Terms of Eligibility, Sperm Designee, Restrictions on Use in Reproduction, Logistics, and Contraindications. We also identified two different approaches to policy structure. In the Limited Role approach, institutions have stricter consent requirements and limit their involvement to the time of procurement. In the Family-Centered approach, substituted judgment is permitted but a mandatory wait period is enforced before sperm use in reproduction. Institutions seeking to implement a PSP protocol will benefit from considering the six major building blocks of a thorough protocol and where they would like to fall on the spectrum from a Limited Role to a Family-Centered approach. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Chaimani, Anna; Caldwell, Deborah M; Li, Tianjing; Higgins, Julian P T; Salanti, Georgia
2017-03-01
The number of systematic reviews that aim to compare multiple interventions using network meta-analysis is increasing. In this study, we highlight aspects of a standard systematic review protocol that may need modification when multiple interventions are to be compared. We take the protocol format suggested by Cochrane for a standard systematic review as our reference and compare the considerations for a pairwise review with those required for a valid comparison of multiple interventions. We suggest new sections for protocols of systematic reviews including network meta-analyses with a focus on how to evaluate their assumptions. We provide example text from published protocols to exemplify the considerations. Standard systematic review protocols for pairwise meta-analyses need extensions to accommodate the increased complexity of network meta-analysis. Our suggested modifications are widely applicable to both Cochrane and non-Cochrane systematic reviews involving network meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.
Improvement of burn pain management through routine pain monitoring and pain management protocol.
Yang, Hyeong Tae; Hur, Giyeun; Kwak, In-Suk; Yim, Haejun; Cho, Yong Suk; Kim, Dohern; Hur, Jun; Kim, Jong Hyun; Lee, Boung Chul; Seo, Cheong Hoon; Chun, Wook
2013-06-01
Pain management is an important aspect of burn management. We developed a routine pain monitoring system and pain management protocol for burn patients. The purpose of this study is to evaluate the effectiveness of our new pain management system. From May 2011 to November 2011, the prospective study was performed with 107 burn patients. We performed control group (n=58) data analysis and then developed the pain management protocol and monitoring system. Next, we applied our protocol to patients and performed protocol group (n=49) data analysis, and compared this to control group data. Data analysis was performed using the Numeric Rating Scale (NRS) of background pain and procedural pain, Clinician-Administered PTSD Scale (CAPS), Hamilton Depression Rating Scale (HDRS), State-Trait Anxiety Inventory Scale (STAIS), and Holmes and Rahe Stress Scale (HRSS). The NRS of background pain for the protocol group was significantly decreased compared to the control group (2.8±2.0 versus 3.9±1.9), and the NRS of procedural pain of the protocol group was significantly decreased compared to the control group (4.8±2.8 versus 3.7±2.5). CAPS and HDRS were decreased in the protocol group, but did not have statistical significance. STAIS and HRSS were decreased in the protocol group, but only the STAIS had statistical significance. Our new pain management system was effective in burn pain management. However, adequate pain management can only be accomplished by a continuous and thorough effort. Therefore, pain control protocol and pain monitoring systems need to be under constant revision and improvement using creative ideas and approaches. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Design and development of compact monitoring system for disaster remote health centres.
Santhi, S; Sadasivam, G S
2015-02-01
To enhance speedy communication between the patient and the doctor through newly proposed routing protocol at the mobile node. The proposed model is applied for a telemedicine application during disaster recovery management. In this paper, Energy Efficient Link Stability Routing Protocol (EELSRP) has been developed by simulation and real time. This framework is designed for the immediate healing of affected persons in remote areas, especially at the time of the disaster where there is no hospital proximity. In case of disasters, there might be an outbreak of infectious diseases. In such cases, the patient's medical record is also transferred by the field operator from disaster place to the hospital to facilitate the identification of the disease-causing agent and to prescribe the necessary medication. The heterogeneous networking framework provides reliable, energy efficientand speedy communication between the patient and the doctor using the proposed routing protocol at the mobile node. The performance of the simulation and real time versions of the Energy Efficient Link Stability Routing Protocol (EELSRP) protocol has been analyzed. Experimental results prove the efficiency of the real-time version of EESLRP protocol. The packet delivery ratio and throughput of the real time version of EELSRP protocol is increased by 3% and 10%, respectively, when compared to the simulated version of EELSRP. The end-to-end delay and energy consumption are reduced by 10% and 2% in the real time version of EELSRP.
Yousefzadeh, Abbas; Olyaei, Gholam Reza; Naseri, Nasrin; Khazaeipour, Zahra
2018-01-01
Objective The Hölmich protocol in therapeutic exercise is the most appropriate method for the treatment of long-standing adductor-related groin pain (LSAGP). Herein, we evaluated a modified Hölmich protocol to resolve the possible limitations intrinsic to the Hölmich protocol in terms of the rate of return to sport and the recovery period for athletes with LSAGP. Design The study followed a single-blind, before/after study design, where 15 athletes with LSAGP (mean age = 26.13 years; SD = 4.48) performed a 10-week modified Hölmich therapeutic exercise protocol. Results Outcome scores related to pain, hip adductor and abductor muscle strengths, and the ratio of maximum isometric and eccentric hip adduction to abduction strength increased significantly. Likewise, hip abduction and internal rotation ROM improved significantly compared to that at baseline. Furthermore, functional records (t-test, Edgren Side Step Test, and Triple Hop Test) showed significant improvement after treatment. Finally, 13 athletes (86.6% of the participants) successfully returned to sports activity in a mean time of 12.06 weeks (SD = 3.41). Conclusion The findings of this study objectively show that the modified Hölmich protocol may be safer and more effective than the Hölmich protocol in athletes with LSAGP in promoting their return to sports activity. This trial is registered with IRCT2016080829269N1. PMID:29721339
Zebrack, Brad; Kayser, Karen; Bybee, Deborah; Padgett, Lynne; Sundstrom, Laura; Jobin, Chad; Oktay, Julianne
2017-07-01
Background: This study examined the extent to which cancer programs demonstrated adherence to their own prescribed screening protocol, and whether adherence to that protocol was associated with medical service utilization. The hypothesis is that higher rates of service utilization are associated with lower rates of adherence to screening protocols. Methods: Oncology social workers at Commission on Cancer-accredited cancer programs reviewed electronic health records (EHRs) in their respective cancer programs during a 2-month period in 2014. Rates of overall adherence to a prescribed distress screening protocol were calculated based on documentation in the EHR that screening adherence and an appropriate clinical response had occurred. We examined documentation of emergency department (ED) use and hospitalization within 2 months after the screening visit. Results: Review of 8,409 EHRs across 55 cancer centers indicated that the overall adherence rate to screening protocols was 62.7%. The highest rates of adherence were observed in Community Cancer Programs (76.3%) and the lowest rates were in NCI-designated Cancer Centers (43.3%). Rates of medical service utilization were significantly higher than expected when overall protocol adherence was lacking. After controlling for patient and institutional characteristics, risk ratios for ED use (0.82) and hospitalization (0.81) suggest that when overall protocol adherence was documented, 18% to 19% fewer patients used these medical services. Conclusions: The observed associations between a mandated psychosocial care protocol and medical service utilization suggest opportunities for operational efficiencies and costs savings. Further investigations of protocol integrity, as well as the clinical care models by which psychosocial care is delivered, are warranted. Copyright © 2017 by the National Comprehensive Cancer Network.
A comparison of VO2max and metabolic variables between treadmill running and treadmill skating.
Koepp, Kriston K; Janot, Jeffrey M
2008-03-01
The purpose of this study was to determine differences in VO2max and metabolic variables between treadmill running and treadmill skating. This study also examined VO2max responses during a continuous skating treadmill protocol and a discontinuous skating treadmill protocol. Sixteen male high school hockey players, who had a mean age of 16 +/- 1 years and were of an above-average fitness level, participated in this study. All subjects completed 4 exercise trials: a 1-hour skating treadmill familiarization trial, a treadmill running trial, and 2 randomized skating treadmill trials. Minute ventilation (VE), oxygen consumption VO2), carbon dioxide production VCO2), respiratory exchange ratio (RER), and heart rate were averaged every 15 seconds up to VO2max for each exercise test. The results showed that there was a significant difference (P < 0.05) for VO2max (mL.kg.min) and maximal VCO2 (L.min) between the running treadmill protocol and discontinuous skating treadmill protocol. There was also a significant difference for maximal RER between the discontinuous and continuous skating treadmill protocol and between the discontinuous skating treadmill protocol and running treadmill protocol. In conclusion, the running treadmill elicited a greater VO2max (mL.kg.min) than the skating treadmill did, but when it comes to specificity of ice skating, the skating treadmill may be ideal. Also, there was no significant difference between the discontinuous and continuous skating treadmill protocols. Therefore, a continuous protocol is possible on the skating treadmill without compromising correct skating position and physiologic responses. However, the continuous skating treadmill protocol should undergo validation before other scientists, coaches, and strength and conditioning professionals can apply it correctly.
[Acoustic voice analysis using the Praat program: comparative study with the Dr. Speech program].
Núñez Batalla, Faustino; González Márquez, Rocío; Peláez González, M Belén; González Laborda, Irene; Fernández Fernández, María; Morato Galán, Marta
2014-01-01
The European Laryngological Society (ELS) basic protocol for functional assessment of voice pathology includes 5 different approaches: perception, videostroboscopy, acoustics, aerodynamics and subjective rating by the patient. In this study we focused on acoustic voice analysis. The purpose of the present study was to correlate the results obtained by the commercial software Dr. Speech and the free software Praat in 2 fields: 1. Narrow-band spectrogram (the presence of noise according to Yanagihara, and the presence of subharmonics) (semi-quantitative). 2. Voice acoustic parameters (jitter, shimmer, harmonics-to-noise ratio, fundamental frequency) (quantitative). We studied a total of 99 voice samples from individuals with Reinke's oedema diagnosed using videostroboscopy. One independent observer used Dr. Speech 3.0 and a second one used the Praat program (Phonetic Sciences, University of Amsterdam). The spectrographic analysis consisted of obtaining a narrow-band spectrogram from the previous digitalised voice samples by the 2 independent observers. They then determined the presence of noise in the spectrogram, using the Yanagihara grades, as well as the presence of subharmonics. As a final result, the acoustic parameters of jitter, shimmer, harmonics-to-noise ratio and fundamental frequency were obtained from the 2 acoustic analysis programs. The results indicated that the sound spectrogram and the numerical values obtained for shimmer and jitter were similar for both computer programs, even though types 1, 2 and 3 voice samples were analysed. The Praat and Dr. Speech programs provide similar results in the acoustic analysis of pathological voices. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Pore network quantification of sandstones under experimental CO2 injection using image analysis
NASA Astrophysics Data System (ADS)
Berrezueta, Edgar; González-Menéndez, Luís; Ordóñez-Casado, Berta; Olaya, Peter
2015-04-01
Automated-image identification and quantification of minerals, pores and textures together with petrographic analysis can be applied to improve pore system characterization in sedimentary rocks. Our case study is focused on the application of these techniques to study the evolution of rock pore network subjected to super critical CO2-injection. We have proposed a Digital Image Analysis (DIA) protocol that guarantees measurement reproducibility and reliability. This can be summarized in the following stages: (i) detailed description of mineralogy and texture (before and after CO2-injection) by optical and scanning electron microscopy (SEM) techniques using thin sections; (ii) adjustment and calibration of DIA tools; (iii) data acquisition protocol based on image capture with different polarization conditions (synchronized movement of polarizers); (iv) study and quantification by DIA that allow (a) identification and isolation of pixels that belong to the same category: minerals vs. pores in each sample and (b) measurement of changes in pore network, after the samples have been exposed to new conditions (in our case: SC-CO2-injection). Finally, interpretation of the petrography and the measured data by an automated approach were done. In our applied study, the DIA results highlight the changes observed by SEM and microscopic techniques, which consisted in a porosity increase when CO2 treatment occurs. Other additional changes were minor: variations in the roughness and roundness of pore edges, and pore aspect ratio, shown in the bigger pore population. Additionally, statistic tests of pore parameters measured were applied to verify that the differences observed between samples before and after CO2-injection were significant.
Velasco-Orjuela, Gina P; Domínguez-Sanchéz, María A; Hernández, Enrique; Correa-Bautista, Jorge E; Triana-Reina, Héctor R; García-Hermoso, Antonio; Peña-Ibagon, Jhonatan C; Izquierdo, Mikel; Cadore, Eduardo L; Hackney, Anthony C; Ramírez-Vélez, Robinson
2018-06-22
The purpose of this study was to compare the hormonal responses to one session of high-intensity interval training (HIIT, 4 × 4 min intervals at 85-95% maximum heart rate [HRmax], interspersed with 4 min of recovery at 75-85% HRmax), resistance training (RT at 50-70% of one repetition maximum 12-15 repetitions per set with 60s of recovery) or both (HIIT+RT) exercise protocol in a cohort of physical inactivity, overweight adults (age 18-30 years old). Randomized, parallel-group clinical trial among fifty-one men (23.6 ± 3.5 yr; 83.5 ± 7.8 kg; 28.0 ± 1.9 kg/m2), physical inactivity (i.e., <150 min of moderate-intensity exercise per week for >6 months), with abdominal obesity (waist circumference ≥90 cm) or body mass index ≥25 and ≤30 kg/m 2 were randomized to the following 4 groups: high-intensity interval training (HIIT, n = 14), resistance training (RT, n = 12), combined high-intensity interval and resistance training (HIIT+RT, n = 13), or non-exercising control (CON, n = 12). Cortisol, total- and free-testosterone and total-testosterone/cortisol-ratio (T/C) assessments (all in serum) were determined before (pre) and 1-min post-exercise for each protocol session. Decreases in cortisol levels were -57.08 (95%CI, -75.58 to -38.58; P = 0.001; ɳ 2 = 0.61) and - 37.65 (95%CI, -54.36 to -20.93; P = 0.001; ɳ 2 = 0.51) in the HIIT and control group, respectively. Increases in T/C ratio were 0.022 (95%CI, 0.012 to 0.031; P = 0.001; ɳ 2 = 0.49) and 0.015 (95%CI, 0.004 to 0.025; P = 0.007; ɳ 2 = 0.29) in the HIIT and control group, respectively. In per-protocol analyses revealed a significant change in cortisol levels [interaction effect F( 7.777 ), ɳ 2 = 0.33] and T/C ratio [interaction effect F( 5.298 ), ɳ 2 = 0.25] between groups over time. Additionally, we showed that in both the intention-to-treat (ITT) and per protocol analyses, HIIT+RT did not change serum cortisol, total or free testosterone. The present data indicate a HIIT reduced cortisol and increased total-testosterone/cortisol-ratio levels significantly in physically inactive adults. Further study is required to determine the biological importance of these changes in hormonal responses in overweight men. Copyright © 2018. Published by Elsevier Inc.
Sánchez-Doblado, F; Andreo, P; Capote, R; Leal, A; Perucha, M; Arráns, R; Núñez, L; Mainegra, E; Lagares, J I; Carrasco, E
2003-07-21
Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the same level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm2 beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm2, confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s(w,air) was up to 1.1%, indicating that the use of protocol data for narrow beams in such cases is less accurate than at low energies, and detailed calculations of the dosimetry parameters involved should be performed if similar accuracy to that of 6 MV is sought.
NASA Astrophysics Data System (ADS)
Torres, Veronica C.; Wilson, Todd; Staneviciute, Austeja; Byrne, Richard W.; Tichauer, Kenneth M.
2018-03-01
Skull base tumors are particularly difficult to visualize and access for surgeons because of the crowded environment and close proximity of vital structures, such as cranial nerves. As a result, accidental nerve damage is a significant concern and the likelihood of tumor recurrence is increased because of more conservative resections that attempt to avoid injuring these structures. In this study, a paired-agent imaging method with direct administration of fluorophores is applied to enhance cranial nerve identification. Here, a control imaging agent (ICG) accounts for non-specific uptake of the nerve-targeting agent (Oxazine 4), and ratiometric data analysis is employed to approximate binding potential (BP, a surrogate of targeted biomolecule concentration). For clinical relevance, animal experiments and simulations were conducted to identify parameters for an optimized stain and rinse protocol using the developed paired-agent method. Numerical methods were used to model the diffusive and kinetic behavior of the imaging agents in tissue, and simulation results revealed that there are various combinations of stain time and rinse number that provide improved contrast of cranial nerves, as suggested by optimal measures of BP and contrast-to-noise ratio.
Fatigue influences lower extremity angular velocities during a single-leg drop vertical jump.
Tamura, Akihiro; Akasaka, Kiyokazu; Otsudo, Takahiro; Shiozawa, Junya; Toda, Yuka; Yamada, Kaori
2017-03-01
[Purpose] Fatigue alters lower extremity landing strategies and decreases the ability to attenuate impact during landing. The purpose of this study was to reveal the influence of fatigue on dynamic alignment and joint angular velocities in the lower extremities during a single leg landing. [Subjects and Methods] The 34 female college students were randomly assigned to either the fatigue or control group. The fatigue group performed single-leg drop vertical jumps before, and after, the fatigue protocol, which was performed using a bike ergometer. Lower extremity kinematic data were acquired using a three-dimensional motion analysis system. The ratio of each variable (%), for the pre-fatigue to post-fatigue protocols, were calculated to compare differences between each group. [Results] Peak hip and knee flexion angular velocities increased significantly in the fatigue group compared with the control group. Furthermore, hip flexion angular velocity increased significantly between each group at 40 milliseconds after initial ground contact. [Conclusion] Fatigue reduced the ability to attenuate impact by increasing angular velocities in the direction of hip and knee flexion during landings. These findings indicate a requirement to evaluate movement quality over time by measuring hip and knee flexion angular velocities in landings during fatigue conditions.
Comparative analysis of protocols for DNA extraction from soybean caterpillars.
Palma, J; Valmorbida, I; da Costa, I F D; Guedes, J V C
2016-04-07
Genomic DNA extraction is crucial for molecular research, including diagnostic and genome characterization of different organisms. The aim of this study was to comparatively analyze protocols of DNA extraction based on cell lysis by sarcosyl, cetyltrimethylammonium bromide, and sodium dodecyl sulfate, and to determine the most efficient method applicable to soybean caterpillars. DNA was extracted from specimens of Chrysodeixis includens and Spodoptera eridania using the aforementioned three methods. DNA quantification was performed using spectrophotometry and high molecular weight DNA ladders. The purity of the extracted DNA was determined by calculating the A260/A280 ratio. Cost and time for each DNA extraction method were estimated and analyzed statistically. The amount of DNA extracted by these three methods was sufficient for PCR amplification. The sarcosyl method yielded DNA of higher purity, because it generated a clearer pellet without viscosity, and yielded high quality amplification products of the COI gene I. The sarcosyl method showed lower cost per extraction and did not differ from the other methods with respect to preparation times. Cell lysis by sarcosyl represents the best method for DNA extraction in terms of yield, quality, and cost effectiveness.
Performance analysis of optimal power allocation in wireless cooperative communication systems
NASA Astrophysics Data System (ADS)
Babikir Adam, Edriss E.; Samb, Doudou; Yu, Li
2013-03-01
Cooperative communication has been recently proposed in wireless communication systems for exploring the inherent spatial diversity in relay channels.The Amplify-and-Forward (AF) cooperation protocols with multiple relays have not been sufficiently investigated even if it has a low complexity in term of implementation. We consider in this work a cooperative diversity system in which a source transmits some information to a destination with the help of multiple relay nodes with AF protocols and investigate the optimality of allocating powers both at the source and the relays system by optimizing the symbol error rate (SER) performance in an efficient way. Firstly we derive a closedform SER formulation for MPSK signal using the concept of moment generating function and some statistical approximations in high signal to noise ratio (SNR) for the system under studied. We then find a tight corresponding lower bound which converges to the same limit as the theoretical upper bound and develop an optimal power allocation (OPA) technique with mean channel gains to minimize the SER. Simulation results show that our scheme outperforms the equal power allocation (EPA) scheme and is tight to the theoretical approximation based on the SER upper bound in high SNR for different number of relays.
Kinesio Taping for pain control during labor: Protocol of a randomized, controlled trial.
Miquelutti, Maria Amelia; Cecatti, José Guilherme
2017-03-01
This study protocol will evaluate the effectiveness and safety during labor and delivery of the Kinesio Taping bandage for pain sensation, satisfaction of patients, and obstetric and neonatal outcomes. A randomized controlled trial with 60 participants divided into two groups will be conducted. The intervention group will receive bandage application on the vertebral regions corresponding to uterine dermatomes - from T10 to L1 and from S2 to S4. The control group will receive bandage application away from uterine dermatomes, from T1 to T4. The primary endpoint is pain during labor. Secondary endpoints are perinatal outcomes and patient satisfaction with the bandage and with her labor. Pain levels will be evaluated on an hourly basis during labor, and intention-to-treat analysis will be performed. Risk ratios and 95% confidence intervals will be calculated. Findings on effectiveness of pain control with no adverse effects to both the mother and neonate are the first step in evaluating the systematic use of Kinesio Taping during labor. Since self-control may affect birthing experience satisfaction, discovering new alternatives for pain control may allow for a better experience. © 2017 John Wiley & Sons Australia, Ltd.
Bush, M; Raath, J P; Phillips, L G; Lance, W
2004-03-01
A combination of medetomidine hydrochloride (medetomidine) and ketamine hydrochloride (ketamine) was evaluated in 16 boma-confined and 19 free-ranging impalas (Aepyceros melampus) to develop a non-opiate immobilisation protocol. In free-ranging impala a dose of 220 +/- 34 microg/kg medetomidine and 4.4 +/- 0.7 mg/kg ketamine combined with 7500 IU of hyaluronidase induced recumbency within 4.5 +/- 1.5 min, with good muscle relaxation, a stable heart rate and blood pH. PaCO2 was maintained within acceptable ranges. The animals were hypoxic with reduced oxygen saturation and low PaO2 in the presence of an elevated respiration rate, therefore methods for respiratory support are indicated. The depth of sedation was adequate for minor manipulations but additional anaesthesia is indicated for painful manipulations. Immobilisation was reversed by 467 +/- 108 microg/kg atipamezole hydrochloride (atipamezole) intramuscularly, but re-sedation was observed several hours later, possibly due to a low atipamezole:medetomidine ratio of 2:1. Therefore, this immobilisation and reversal protocol would subject impalas to possible predation or conspecific aggression following reversal if they were released into the wild. If the protocol is used on free-ranging impala, an atipamezole:medetomidine ratio of 5:1 should probably be used to prevent re-sedation.
Nishizawa, Toshihiro; Nishizawa, Yuko; Yahagi, Naohisa; Kanai, Takanori; Takahashi, Masahiko; Suzuki, Hidekazu
2014-12-01
Several studies have reported that the application of rebamipide during the eradication of Helicobacter pylori can improve the eradication rate. However, the efficacy and safety are controversial. The present study systematically evaluated whether rebamipide improves the eradication rate of H. pylori by conducting a meta-analysis based on randomized controlled trials (RCTs). Literature searches were conducted in the following database: PubMed, the Cochrane Library, and the Igaku-chuo-zasshi database in Japan. A meta-analysis of all RCTs comparing rebamipide supplementation with non-rebamipide-containing therapy was performed. We identified six randomized trials (611 patients). Pooled H. pylori eradication rates by per-protocol analysis were 73.3% and 61.4% for patients with or without rebamipide, respectively. The odds ratio was 1.74 (95% confidence interval. 1.19-2.53). Supplementation with rebamipide might be effective in increasing the H. pylori eradication rates of proton-pump inhibitor-amoxicillin dual therapy. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Pilot proficiency testing study for second tier congenital adrenal hyperplasia newborn screening.
De Jesús, Víctor R; Simms, David A; Schiffer, Jarad; Kennedy, Meredith; Mei, Joanne V; Hannon, W Harry
2010-11-11
Congenital adrenal hyperplasia (CAH) is caused by inherited defects in steroid biosynthesis. The Newborn Screening Quality Assurance Program (NSQAP) initiated a pilot, dried-blood spot (DBS)-based proficiency testing program designed to investigate materials and laboratory performance for second tier CAH screening by tandem mass spectrometry (MS/MS). The ratio of 17-α-hydroxyprogesterone (17-OHP), androstenedione (4-AD) and cortisol is used as an indicator of CAH in laboratory protocols for second tier analysis of DBS specimens. DBS prepared by NSQAP contained a range of steroid concentrations resulting in different clinical ratios. Laboratories received blind-coded DBS specimens and reported results to NSQAP for evaluation. Quantitative values reported by participants for 17-OHP, 4-AD, and cortisol, reflected small differences in their analytical methods. Average quantitative values for 17-OHP increased from 81% to 107% recovery over the 3.5-year period; cortisol recoveries increased from 61.9% to 89.5%; and 4-AD recoveries decreased from 184% to 68%. Laboratory participation in the CAH second tier proficiency testing program has resulted in improved analyte recoveries and enhanced sample preparation methodologies. NSQAP services for the second tier CAH analysis in DBS demonstrate the need for surveillance to ensure harmonization and continuous improvements, and to achieve sustained high-performance of newborn screening laboratories worldwide. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Vadivel, R.; Bhaskaran, V. Murali
2010-10-01
The main reason for packet loss in ad hoc networks is the link failure or node failure. In order to increase the path stability, it is essential to distinguish and moderate the failures. By knowing individual link stability along a path, path stability can be identified. In this paper, we develop an adaptive reliable routing protocol using combined link stability estimation for mobile ad hoc networks. The main objective of this protocol is to determine a Quality of Service (QoS) path along with prolonging the network life time and to reduce the packet loss. We calculate a combined metric for a path based on the parameters Link Expiration Time, Node Remaining Energy and Node Velocity and received signal strength to predict the link stability or lifetime. Then, a bypass route is established to retransmit the lost data, when a link failure occurs. By simulation results, we show that the proposed reliable routing protocol achieves high delivery ratio with reduced delay and packet drop.
An Energy-Efficient and Robust Multipath Routing Protocol for Cognitive Radio Ad Hoc Networks.
Singh, Kishor; Moh, Sangman
2017-09-04
Routing in cognitive radio ad hoc networks (CRAHNs) is a daunting task owing to dynamic topology, intermittent connectivity, spectrum heterogeneity, and energy constraints. Other prominent aspects such as channel stability, path reliability, and route discovery frequency should also be exploited. Several routing protocols have been proposed for CRAHNs in the literature. By stressing on one of the aspects more than any other, however, they do not satisfy all requirements of throughput, energy efficiency, and robustness. In this paper, we propose an energy-efficient and robust multipath routing (ERMR) protocol for CRAHNs by considering all prominent aspects including residual energy and channel stability in design. Even when the current routing path fails, the alternative routing path is immediately utilized. In establishing primary and alternative routing paths, both residual energy and channel stability are exploited simultaneously. Our simulation study shows that the proposed ERMR outperforms the conventional protocol in terms of network throughput, packet delivery ratio, energy consumption, and end-to-end delay.
Adaptive and reliably acknowledged FSO communications
NASA Astrophysics Data System (ADS)
Fitz, Michael P.; Halford, Thomas R.; Kose, Cenk; Cromwell, Jonathan; Gordon, Steven
2015-05-01
Atmospheric turbulence causes the receive signal intensity on free space optical (FSO) communication links to vary over time. Scintillation fades can stymie connectivity for milliseconds at a time. To approach the information-theoretic limits of communication in such time-varying channels, it necessary to either code across extremely long blocks of data - thereby inducing unacceptable delays - or to vary the code rate according to the instantaneous channel conditions. We describe the design, laboratory testing, and over-the-air testing of an FSO modem that employs a protocol with adaptive coded modulation (ACM) and hybrid automatic repeat request. For links with fixed throughput, this protocol provides a 10dB reduction in the required received signal-to-noise ratio (SNR); for links with fixed range, this protocol provides the greater than a 3x increase in throughput. Independent U.S. Government tests demonstrate that our protocol effectively adapts the code rate to match the instantaneous channel conditions. The modem is able to provide throughputs in excess of 850 Mbps on links with ranges greater than 15 kilometers.
PRP: peripheral routing protocol for WSN realistic marginal mobility model
NASA Astrophysics Data System (ADS)
Tudorache, I. G.; Popescu, A. M.; Kemp, A. H.
2017-02-01
This article proposes a new routing protocol called Peripheral Routing Protocol (PRP) for the scenario where the mobile destination (D) moves at the wireless sensor network (WSN) periphery for gathering data. From a connectivity point of view, when D follows the marginal mobility model (MMM), the WSN becomes a hybrid network: a sparse network, because of the interrupted connectivity between D and the rest of the nodes and a well-connected network, because of the connectivity between all the other nodes of the WSN except D. It will be proven through MATLAB simulations that, for a military application scenario where D's connectivity to the WSN varies between 10% and 95%, compared with the 100% case, PRP outperforms routing protocols recommended for Mobile Ad-hoc Networks (MANET) in three ways: it maintains an average Packet Delivery Ratio (PDR) over 90%, a below 10% and 5% increase for the Average End to End Delay (AETED) and energy per transmitted packet.
An Energy-Efficient and Robust Multipath Routing Protocol for Cognitive Radio Ad Hoc Networks
Singh, Kishor
2017-01-01
Routing in cognitive radio ad hoc networks (CRAHNs) is a daunting task owing to dynamic topology, intermittent connectivity, spectrum heterogeneity, and energy constraints. Other prominent aspects such as channel stability, path reliability, and route discovery frequency should also be exploited. Several routing protocols have been proposed for CRAHNs in the literature. By stressing on one of the aspects more than any other, however, they do not satisfy all requirements of throughput, energy efficiency, and robustness. In this paper, we propose an energy-efficient and robust multipath routing (ERMR) protocol for CRAHNs by considering all prominent aspects including residual energy and channel stability in design. Even when the current routing path fails, the alternative routing path is immediately utilized. In establishing primary and alternative routing paths, both residual energy and channel stability are exploited simultaneously. Our simulation study shows that the proposed ERMR outperforms the conventional protocol in terms of network throughput, packet delivery ratio, energy consumption, and end-to-end delay. PMID:28869551
Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.
Stern, C H; Jaasma, D R; Champion, M R
1993-03-01
A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.
Jost, Gregor; Endrikat, Jan; Pietsch, Hubertus
2017-01-01
To compare injector-based contrast agent (CA) administration with hand injection in magnetic resonance angiography (MRA). Gadobutrol was administered in 6 minipigs with 3 protocols: (a) hand injection (one senior technician), (b) hand injection (6 less-experienced technicians), and (c) power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.
Chu-Su, Yu; Shukuya, Kenichi; Yokoyama, Takashi; Lin, Wei-Chou; Chiang, Chih-Kang; Lin, Chii-Wann
2017-01-11
Urinary sediment is used to evaluate patients with possible urinary tract diseases. Currently, numerous protocols are applied to detect dysmorphic red blood cells (RBCs) and renal tubular epithelial cells (RTECs) in urinary sediment. However, distinct protocols are used by nephrologists and medical technologists for specimen concentration and observation, which leads to major discrepancies in the differential counts of formed elements such as dysmorphic RBCs and RTECs and might interfere with an accurate clinical diagnosis. To resolve these problems, we first tested a modified urinalysis protocol with an increased relative centrifuge force and concentration factor in 20 biopsy-confirmed glomerulonephritis patients with haematuria. We successfully improved the recovery ratio of dysmorphic RBCs in clinical specimens from 34.7% to 42.0% (P < 0.001). Furthermore, we confirmed the correlation between counts by the modified urinary protocol and Sysmex UF-1000i urinary flow cytometer (r ≥ 0.898, P < 0.001). A total of 28 types of isomorphic and dysmorphic RBCs were detected using a bright field microscope, with results comparable to those using a standard phase contrast microscope. Finally, we applied Sternheimer stain to enhance the contrast of RTECs in the urinary sediments. We concluded that this modified urinalysis protocol significantly enhanced the quality of urinalysis.
Chu-Su, Yu; Shukuya, Kenichi; Yokoyama, Takashi; Lin, Wei-Chou; Chiang, Chih-Kang; Lin, Chii-Wann
2017-01-01
Urinary sediment is used to evaluate patients with possible urinary tract diseases. Currently, numerous protocols are applied to detect dysmorphic red blood cells (RBCs) and renal tubular epithelial cells (RTECs) in urinary sediment. However, distinct protocols are used by nephrologists and medical technologists for specimen concentration and observation, which leads to major discrepancies in the differential counts of formed elements such as dysmorphic RBCs and RTECs and might interfere with an accurate clinical diagnosis. To resolve these problems, we first tested a modified urinalysis protocol with an increased relative centrifuge force and concentration factor in 20 biopsy-confirmed glomerulonephritis patients with haematuria. We successfully improved the recovery ratio of dysmorphic RBCs in clinical specimens from 34.7% to 42.0% (P < 0.001). Furthermore, we confirmed the correlation between counts by the modified urinary protocol and Sysmex UF-1000i urinary flow cytometer (r ≥ 0.898, P < 0.001). A total of 28 types of isomorphic and dysmorphic RBCs were detected using a bright field microscope, with results comparable to those using a standard phase contrast microscope. Finally, we applied Sternheimer stain to enhance the contrast of RTECs in the urinary sediments. We concluded that this modified urinalysis protocol significantly enhanced the quality of urinalysis. PMID:28074941
Pan, Hui; Ba-Thein, William
2018-01-01
Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.
Failure of antiarrhythmic drugs to prevent experimental reperfusion ventricular fibrillation.
Naito, M; Michelson, E L; Kmetzo, J J; Kaplinsky, E; Dreifus, L S
1981-01-01
Ninety-nine adult mongrel dogs underwent acute ligation of the proximal left anterior descending coronary artery. Thirty minutes later, the occlusion was released to evaluate the effectiveness of five antiarrhythmic protocols in eliminating reperfusion ventricular fibrillation. The five protocols included: protocol 1 --i.v. lidocaine, preligation and prerelease (n = 19); protocol 2 -- i.v. lidocaine, prereperfusion only (n = 22); protocol 3 -- chronic, oral, daily amiodarone for 2 weeks preligation (n = 19); protocol 4 -- i.v. procainamide, preligation and prereperfusion (n = 21); and protocol 5 -- i.v. verapamil, prereperfusion (n = 18). Each regimen was evaluated with respect to the incidence of reperfusion ventricular fibrillation in dogs that survived to reperfusion, and the results were compared to 77 control dogs that underwent identical coronary artery occlusion and release procedures without drug therapy. The incidence of reperfusion ventricular fibrillation was as follows: protocol 1 -- seven of 15 dogs (47%); protocol 2 -- six of 18 (33%); protocol 3 -- 11 of 16 dogs (69%); protocol 4 -- eight of 17 dogs (47%); and protocol 5 -- 10 of 17 dogs (59%), compared with 36 of 60 (60%) in control dogs. Using chi-square analysis, protocol 2 was beneficial (p < 0.05). The dogs were then stratified into high- and low-risk subgroups based on the arrhythmic events of the antecedent coronary artery ligation periods, and predictive risk indexes for the occurrence of reperfusion ventricular fibrillation were developed. the Mantel-Haenszel method of statistical analysis revealed that none of these protocols resulted in a statistically significant reduction in the incidence of reperfusion ventricular fibrillation. Thus, use of these predictive indexes plus appropriate statistical methods has revealed, unexpectedly, limitations in the efficacy of a spectrum of antiarrhythmic agents in preventing reperfusion ventricular fibrillation.
Wang, Jiun-Long; Chin, Chun-Shih; Chang, Ming-Chen; Yi, Chi-Yuan; Shih, Sou-Jen; Hsu, Jeng-Yuan; Wu, Chieh-Liang
2009-10-01
Severe sepsis and septic shock are life-threatening disorders. Integrating treatments into a bundle strategy has been proposed to facilitate timely resuscitation, but is difficult to implement. We implemented protocol-driven therapy for severe sepsis, and analyzed retrospectively the key process indicators of mortality in managing sepsis. Continuous quality improvement was begun to implement a tailored protocol-driven therapy for sepsis in a 24-bed respiratory intensive care unit (RICU) of Taichung Veterans General Hospital from January 2007 to February 2008. Patients, who were admitted to the RICU directly, or within 24 hours, were enrolled if they met the criteria for severe sepsis and septic shock. Disease severity [Acute Physiology and Chronic Health Evaluation (APACHE) II and lactate level], causes of sepsis, comorbidity and site of sepsis onset were recorded. Process-of-care indicators included resuscitation time (Tr-s), RICU bed availability (Ti-s) and the ratio of completing the elements of the protocol at 1, 2, 4 and 6 hours. The structure and process-of-care indicators reflated to mortality at 7 days after RICU admission and at RICU discharge were identified retrospectively. Eighty-six patients (mean age, 71 +/- 14 years, 72 men, 14 women, APACHE II, 25.0 +/- 7.0) were enrolled. APACHE II scores and lactate levels were higher for mortality than survival at 7 days after RICU admission (p < 0.01). For the process-of-care indicators, Ti-s (562.2 +/- 483.3 vs.1017.3 +/- 557.8 minutes, p = 0.03) and Tr-s (60.7 +/- 207.8 vs. 248.5 +/- 453.1 minutes, p = 0.07) were shorter for survival than mortality at 7 days after RICU admission. The logistic regression study showed that Tr-s was an important indicator. The ratio of completing the elements of protocols at 1, 2, 4 and 6 hours ranged from 70% to 90% and was not related to mortality. Protocol-driven therapy for sepsis was put into clinical practice. Early resuscitation and ICU bed availability were key process indicators in managing sepsis, to reduce mortality.
Sreemany, Arpita; Bera, Melinda Kumar; Sarkar, Anindya
2017-12-30
The elaborate sampling and analytical protocol associated with conventional dual-inlet isotope ratio mass spectrometry has long hindered high-resolution climate studies from biogenic accretionary carbonates. Laser-based on-line systems, in comparison, produce rapid data, but suffer from unresolvable matrix effects. It is, therefore, necessary to resolve these matrix effects to take advantage of the automated laser-based method. Two marine bivalve shells (one aragonite and one calcite) and one fish otolith (aragonite) were first analysed using a CO 2 laser ablation system attached to a continuous flow isotope ratio mass spectrometer under different experimental conditions (different laser power, sample untreated vs vacuum roasted). The shells and the otolith were then micro-drilled and the isotopic compositions of the powders were measured in a dual-inlet isotope ratio mass spectrometer following the conventional acid digestion method. The vacuum-roasted samples (both aragonite and calcite) produced mean isotopic ratios (with a reproducibility of ±0.2 ‰ for both δ 18 O and δ 13 C values) almost identical to the values obtained using the conventional acid digestion method. As the isotopic ratio of the acid digested samples fall within the analytical precision (±0.2 ‰) of the laser ablation system, this suggests the usefulness of the method for studying the biogenic accretionary carbonate matrix. When using laser-based continuous flow isotope ratio mass spectrometry for the high-resolution isotopic measurements of biogenic carbonates, the employment of a vacuum-roasting step will reduce the matrix effect. This method will be of immense help to geologists and sclerochronologists in exploring short-term changes in climatic parameters (e.g. seasonality) in geological times. Copyright © 2017 John Wiley & Sons, Ltd.
Sichilongo, Kwenga
2004-12-01
Synthetic pyrethroids fragment extensively under electron ionization (EI) conditions to give low mass ions, most of them with the same m/z ratios. This fragmentation is primarily due to the labile ester linkage found in these compounds. In this research we established the best gas chromatography (GC) conditions in the EI mode that served as a benchmark in the development of a chemical ionization (CI) protocol for ten selected synthetic pyrethroids. Based on proton affinity data, several reagent gases were evaluated in the positive CI ionization mode. Methanol was found to produce higher average ion counts relative to the other gases evaluated, which led to the development of an optimized method consisting of selective ejection chemical ionization (SECI) and MS/MS. Standard stainless steel ion trap electrodes produced significant degradation of chromatographic performance on late eluting compounds, which was attributed to electrode surface chemistry. A dramatic improvement in signal-to-noise (S/N) ratios was observed when the chromatographically inert Silcosteel coated electrodes were used. The resulting method, that has significant S/N ratio improvements resulting from a combination of septum programmable injections (SPI), optimized CI and inert Silcosteel-coated electrodes, was used to determine instrument detection limits.
Vitrification and xenografting of human ovarian tissue.
Amorim, Christiani Andrade; Dolmans, Marie-Madeleine; David, Anu; Jaeger, Jonathan; Vanacker, Julie; Camboni, Alessandra; Donnez, Jacques; Van Langendonckt, Anne
2012-11-01
To assess the efficiency of two vitrification protocols to cryopreserve human preantral follicles with the use of a xenografting model. Pilot study. Gynecology research unit in a university hospital. Ovarian biopsies were obtained from seven women aged 30-41 years. Ovarian tissue fragments were subjected to one of three cryopreservation protocols (slow freezing, vitrification protocol 1, and vitrification protocol 2) and xenografted for 1 week to nude mice. The number of morphologically normal follicles after cryopreservation and grafting and fibrotic surface area were determined by histologic analysis. Apoptosis was assessed by the TUNEL method. Morphometric analysis of TUNEL-positive surface area also was performed. Follicle proliferation was evaluated by immunohistochemistry. After xenografting, a difference was observed between the cryopreservation procedures applied. According to TUNEL analysis, both vitrification protocols showed better preservation of preantral follicles than the conventional freezing method. Moreover, histologic evaluation showed a significantly higher proportion of primordial follicles in vitrified (protocol 2)-warmed ovarian tissue than in frozen-thawed tissue. The proportion of growing follicles and fibrotic surface area was similar in all groups. Vitrification procedures appeared to preserve not only the morphology and survival of preantral follicles after 1 week of xenografting, but also their ability to resume folliculogenesis. In addition, vitrification protocol 2 had a positive impact on the quiescent state of primordial follicles after xenografting. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Screening Protocol for Early Identification of Brazilian Children at Risk for Dyslexia
Germano, Giseli D.; César, Alexandra B. P. de C.; Capellini, Simone A.
2017-01-01
Early identification of students at risk of dyslexia has been an educational challenge in the past years. This research had two main goals. First, we aimed to develop a screening protocol for early identification of Brazilian children at risk for dyslexia; second, we aimed to identify the predictive variables of this protocol using Principal Component Analysis. The major step involved in developing this protocol was the selection of variables, which were chosen based on the literature review and linguistic criteria. The screening protocol was composed of seven cognitive-linguistic skills: Letter naming; Phonological Awareness (which comprises the following subtests: Rhyme production, Rhyme identification, Syllabic segmentation, Production of words from a given phoneme, Phonemic Synthesis, and Phonemic analysis); Phonological Working memory, Rapid naming Speed; Silent reading; Reading of words and non-words; and Auditory Comprehension of sentences from pictures. A total of 149 children, aged from 6 years to 6 and 11, of both genders who were enrolled in the 1st grade of elementary public schools were submitted to the screening protocol. Principal Component Analysis revealed four factors, accounting for 64.45% of the variance of the Protocol variables: first factor (“pre-reading”), second factor (“decoding”), third factor (“Reading”), and fourth factor “Auditory processing.” The factors found corroborate those reported in the National and International literature and have been described as early signs of dyslexia and reading problems. PMID:29163246
The purpose of this protocol is to provide guidelines for the analysis of hair samples for total mercury by cold vapor atomic fluorescence (CVAFS) spectrometry. This protocol describes the methodology and all other analytical aspects involved in the analysis. Keywords: hair; s...
Gebhard, Cathérine; Fuchs, Tobias A; Fiechter, Michael; Stehli, Julia; Stähli, Barbara E; Gaemperli, Oliver; Kaufmann, Philipp A
2013-10-01
The accuracy of coronary computed tomography angiography (CCTA) in obese persons is compromised by increased image noise. We investigated CCTA image quality acquired on a high-definition 64-slice CT scanner using modern adaptive statistical iterative reconstruction (ASIR). Seventy overweight and obese patients (24 males; mean age 57 years, mean body mass index 33 kg/m(2)) were studied with clinically-indicated contrast enhanced CCTA. Thirty-five patients underwent a standard definition protocol with filtered backprojection reconstruction (SD-FBP) while 35 patients matched for gender, age, body mass index and coronary artery calcifications underwent a novel high definition protocol with ASIR (HD-ASIR). Segment by segment image quality was assessed using a four-point scale (1 = excellent, 2 = good, 3 = moderate, 4 = non-diagnostic) and revealed better scores for HD-ASIR compared to SD-FBP (1.5 ± 0.43 vs. 1.8 ± 0.48; p < 0.05). The smallest detectable vessel diameter was also improved, 1.0 ± 0.5 mm for HD-ASIR as compared to 1.4 ± 0.4 mm for SD-FBP (p < 0.001). Average vessel attenuation was higher for HD-ASIR (388.3 ± 109.6 versus 350.6 ± 90.3 Hounsfield Units, HU; p < 0.05), while image noise, signal-to-noise ratio and contrast-to noise ratio did not differ significantly between reconstruction protocols (p = NS). The estimated effective radiation doses were similar, 2.3 ± 0.1 and 2.5 ± 0.1 mSv (HD-ASIR vs. SD-ASIR respectively). Compared to a standard definition backprojection protocol (SD-FBP), a newer high definition scan protocol in combination with ASIR (HD-ASIR) incrementally improved image quality and visualization of distal coronary artery segments in overweight and obese individuals, without increasing image noise and radiation dose.
A Novel Cross-Layer Routing Protocol Based on Network Coding for Underwater Sensor Networks
Wang, Hao; Wang, Shilian; Bu, Renfei; Zhang, Eryang
2017-01-01
Underwater wireless sensor networks (UWSNs) have attracted increasing attention in recent years because of their numerous applications in ocean monitoring, resource discovery and tactical surveillance. However, the design of reliable and efficient transmission and routing protocols is a challenge due to the low acoustic propagation speed and complex channel environment in UWSNs. In this paper, we propose a novel cross-layer routing protocol based on network coding (NCRP) for UWSNs, which utilizes network coding and cross-layer design to greedily forward data packets to sink nodes efficiently. The proposed NCRP takes full advantages of multicast transmission and decode packets jointly with encoded packets received from multiple potential nodes in the entire network. The transmission power is optimized in our design to extend the life cycle of the network. Moreover, we design a real-time routing maintenance protocol to update the route when detecting inefficient relay nodes. Substantial simulations in underwater environment by Network Simulator 3 (NS-3) show that NCRP significantly improves the network performance in terms of energy consumption, end-to-end delay and packet delivery ratio compared with other routing protocols for UWSNs. PMID:28786915
WEAMR — A Weighted Energy Aware Multipath Reliable Routing Mechanism for Hotline-Based WSNs
Tufail, Ali; Qamar, Arslan; Khan, Adil Mehmood; Baig, Waleed Akram; Kim, Ki-Hyung
2013-01-01
Reliable source to sink communication is the most important factor for an efficient routing protocol especially in domains of military, healthcare and disaster recovery applications. We present weighted energy aware multipath reliable routing (WEAMR), a novel energy aware multipath routing protocol which utilizes hotline-assisted routing to meet such requirements for mission critical applications. The protocol reduces the number of average hops from source to destination and provides unmatched reliability as compared to well known reactive ad hoc protocols i.e., AODV and AOMDV. Our protocol makes efficient use of network paths based on weighted cost calculation and intelligently selects the best possible paths for data transmissions. The path cost calculation considers end to end number of hops, latency and minimum energy node value in the path. In case of path failure path recalculation is done efficiently with minimum latency and control packets overhead. Our evaluation shows that our proposal provides better end-to-end delivery with less routing overhead and higher packet delivery success ratio compared to AODV and AOMDV. The use of multipath also increases overall life time of WSN network using optimum energy available paths between sender and receiver in WDNs. PMID:23669714
WEAMR-a weighted energy aware multipath reliable routing mechanism for hotline-based WSNs.
Tufail, Ali; Qamar, Arslan; Khan, Adil Mehmood; Baig, Waleed Akram; Kim, Ki-Hyung
2013-05-13
Reliable source to sink communication is the most important factor for an efficient routing protocol especially in domains of military, healthcare and disaster recovery applications. We present weighted energy aware multipath reliable routing (WEAMR), a novel energy aware multipath routing protocol which utilizes hotline-assisted routing to meet such requirements for mission critical applications. The protocol reduces the number of average hops from source to destination and provides unmatched reliability as compared to well known reactive ad hoc protocols i.e., AODV and AOMDV. Our protocol makes efficient use of network paths based on weighted cost calculation and intelligently selects the best possible paths for data transmissions. The path cost calculation considers end to end number of hops, latency and minimum energy node value in the path. In case of path failure path recalculation is done efficiently with minimum latency and control packets overhead. Our evaluation shows that our proposal provides better end-to-end delivery with less routing overhead and higher packet delivery success ratio compared to AODV and AOMDV. The use of multipath also increases overall life time of WSN network using optimum energy available paths between sender and receiver in WDNs.
Shamseer, Larissa; Moher, David; Clarke, Mike; Ghersi, Davina; Liberati, Alessandro; Petticrew, Mark; Shekelle, Paul; Stewart, Lesley A
2015-01-02
Protocols of systematic reviews and meta-analyses allow for planning and documentation of review methods, act as a guard against arbitrary decision making during review conduct, enable readers to assess for the presence of selective reporting against completed reviews, and, when made publicly available, reduce duplication of efforts and potentially prompt collaboration. Evidence documenting the existence of selective reporting and excessive duplication of reviews on the same or similar topics is accumulating and many calls have been made in support of the documentation and public availability of review protocols. Several efforts have emerged in recent years to rectify these problems, including development of an international register for prospective reviews (PROSPERO) and launch of the first open access journal dedicated to the exclusive publication of systematic review products, including protocols (BioMed Central's Systematic Reviews). Furthering these efforts and building on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines, an international group of experts has created a guideline to improve the transparency, accuracy, completeness, and frequency of documented systematic review and meta-analysis protocols--PRISMA-P (for protocols) 2015. The PRISMA-P checklist contains 17 items considered to be essential and minimum components of a systematic review or meta-analysis protocol.This PRISMA-P 2015 Explanation and Elaboration paper provides readers with a full understanding of and evidence about the necessity of each item as well as a model example from an existing published protocol. This paper should be read together with the PRISMA-P 2015 statement. Systematic review authors and assessors are strongly encouraged to make use of PRISMA-P when drafting and appraising review protocols. © BMJ Publishing Group Ltd 2014.
Metaplasticity in human primary somatosensory cortex: effects on physiology and tactile perception
Jones, Christina B.; Lulic, Tea; Bailey, Aaron Z.; Mackenzie, Tanner N.; Mi, Yi Qun; Tommerdahl, Mark
2016-01-01
Theta-burst stimulation (TBS) over human primary motor cortex evokes plasticity and metaplasticity, the latter contributing to the homeostatic balance of excitation and inhibition. Our knowledge of TBS-induced effects on primary somatosensory cortex (SI) is limited, and it is unknown whether TBS induces metaplasticity within human SI. Sixteen right-handed participants (6 females, mean age 23 yr) received two TBS protocols [continuous TBS (cTBS) and intermittent TBS (iTBS)] delivered in six different combinations over SI in separate sessions. TBS protocols were delivered at 30 Hz and were as follows: a single cTBS protocol, a single iTBS protocol, cTBS followed by cTBS, iTBS followed by iTBS, cTBS followed by iTBS, and iTBS followed by cTBS. Measures included the amplitudes of the first and second somatosensory evoked potentials (SEPs) via median nerve stimulation, their paired-pulse ratio (PPR), and temporal order judgment (TOJ). Dependent measures were obtained before TBS and at 5, 25, 50, and 90 min following stimulation. Results indicate similar effects following cTBS and iTBS; increased amplitudes of the second SEP and PPR without amplitude changes to SEP 1, and impairments in TOJ. Metaplasticity was observed such that TOJ impairments following a single cTBS protocol were abolished following consecutive cTBS protocols. Additionally, consecutive iTBS protocols altered the time course of effects when compared with a single iTBS protocol. In conclusion, 30-Hz cTBS and iTBS protocols delivered in isolation induce effects consistent with a TBS-induced reduction in intracortical inhibition within SI. Furthermore, cTBS- and iTBS-induced metaplasticity appear to follow homeostatic and nonhomeostatic rules, respectively. PMID:26984422
Metaplasticity in human primary somatosensory cortex: effects on physiology and tactile perception.
Jones, Christina B; Lulic, Tea; Bailey, Aaron Z; Mackenzie, Tanner N; Mi, Yi Qun; Tommerdahl, Mark; Nelson, Aimee J
2016-05-01
Theta-burst stimulation (TBS) over human primary motor cortex evokes plasticity and metaplasticity, the latter contributing to the homeostatic balance of excitation and inhibition. Our knowledge of TBS-induced effects on primary somatosensory cortex (SI) is limited, and it is unknown whether TBS induces metaplasticity within human SI. Sixteen right-handed participants (6 females, mean age 23 yr) received two TBS protocols [continuous TBS (cTBS) and intermittent TBS (iTBS)] delivered in six different combinations over SI in separate sessions. TBS protocols were delivered at 30 Hz and were as follows: a single cTBS protocol, a single iTBS protocol, cTBS followed by cTBS, iTBS followed by iTBS, cTBS followed by iTBS, and iTBS followed by cTBS. Measures included the amplitudes of the first and second somatosensory evoked potentials (SEPs) via median nerve stimulation, their paired-pulse ratio (PPR), and temporal order judgment (TOJ). Dependent measures were obtained before TBS and at 5, 25, 50, and 90 min following stimulation. Results indicate similar effects following cTBS and iTBS; increased amplitudes of the second SEP and PPR without amplitude changes to SEP 1, and impairments in TOJ. Metaplasticity was observed such that TOJ impairments following a single cTBS protocol were abolished following consecutive cTBS protocols. Additionally, consecutive iTBS protocols altered the time course of effects when compared with a single iTBS protocol. In conclusion, 30-Hz cTBS and iTBS protocols delivered in isolation induce effects consistent with a TBS-induced reduction in intracortical inhibition within SI. Furthermore, cTBS- and iTBS-induced metaplasticity appear to follow homeostatic and nonhomeostatic rules, respectively. Copyright © 2016 the American Physiological Society.
Schaun, Gustavo Z; Del Vecchio, Fabrício B
2018-01-01
Schaun, GZ and Del Vecchio, FB. High-intensity interval exercises' acute impact on heart rate variability: comparison between whole-body and cycle ergometer protocols. J Strength Cond Res 32(1): 223-229, 2018-Study aimed to compare the effects of 2 high-intensity interval training (HIIT) protocols on heart rate variability. Twelve young adult males (23.3 ± 3.9 years, 177.8 ± 7.4 cm, 76.9 ± 12.9 kg) volunteered to participate. In a randomized cross-over design, subjects performed 2 HIIT protocols, 1 on a cycle ergometer (Tabata protocol [TBT]; eight 20-second bouts at 170% Pmax interspersed by 10-second rest) and another with whole-body calisthenic exercises (McRae protocol; eight 20-second all-out intervals interspersed by 10-second rest). Heart rate variability outcomes in the time, frequency, and nonlinear domains were assessed on 3 moments: (a) presession; (b) immediately postsession; and (c) 24 hours postsession. Results revealed that RRmean, Ln rMSSD, Ln high frequency (HF), and Ln low frequency (LF) were significantly reduced immediately postsession (p ≤ 0.001) and returned to baseline 24 h after both protocols. In addition, LF/HF ratio was reduced 24 h postsession (p ≤ 0.01) and SD2 was significantly lower immediately postsession only in TBT. Our main finding was that responses from heart rate autonomic control were similar in both protocols, despite different modes of exercise performed. Specifically, exercises resulted in a high parasympathetic inhibition immediately after session with subsequent recovery within 1 day. These results suggest that subjects were already recovered the day after and can help coaches to better program training sessions with such protocols.
A guideline for the validation of likelihood ratio methods used for forensic evidence evaluation.
Meuwly, Didier; Ramos, Daniel; Haraksim, Rudolf
2017-07-01
This Guideline proposes a protocol for the validation of forensic evaluation methods at the source level, using the Likelihood Ratio framework as defined within the Bayes' inference model. In the context of the inference of identity of source, the Likelihood Ratio is used to evaluate the strength of the evidence for a trace specimen, e.g. a fingermark, and a reference specimen, e.g. a fingerprint, to originate from common or different sources. Some theoretical aspects of probabilities necessary for this Guideline were discussed prior to its elaboration, which started after a workshop of forensic researchers and practitioners involved in this topic. In the workshop, the following questions were addressed: "which aspects of a forensic evaluation scenario need to be validated?", "what is the role of the LR as part of a decision process?" and "how to deal with uncertainty in the LR calculation?". The questions: "what to validate?" focuses on the validation methods and criteria and "how to validate?" deals with the implementation of the validation protocol. Answers to these questions were deemed necessary with several objectives. First, concepts typical for validation standards [1], such as performance characteristics, performance metrics and validation criteria, will be adapted or applied by analogy to the LR framework. Second, a validation strategy will be defined. Third, validation methods will be described. Finally, a validation protocol and an example of validation report will be proposed, which can be applied to the forensic fields developing and validating LR methods for the evaluation of the strength of evidence at source level under the following propositions. Copyright © 2016. Published by Elsevier B.V.
Pastore, Lisa M; Williams, Christopher D; Jenkins, Jeffrey; Patrie, James T
2011-10-01
Acupuncture may represent a nonpharmaceutical treatment for women with polycystic ovary syndrome (PCOS), based on four studies. The objective of the study was to determine whether true, as compared with sham, acupuncture normalizes pituitary gonadotropin hormones and increases ovulatory frequency in women with PCOS. This was a randomized, double-blind, sham-controlled clinical trial (5 month protocol). The study was conducted in central Virginia. Eighty-four reproductive-aged women completed the intervention. Eligibility required a PCOS diagnosis and no hormonal intervention 60 d before enrollment. Intervention included 12 sessions of true or sham acupuncture (Park sham device) for 8 wk. Serum LH and FSH at baseline, after intervention, and 3 months later were measured. Ovulation was measured with weekly urine or blood samples. Both arms demonstrated a similar mean ovulation rate over the 5 months (0.37/month among n = 40 true acupuncture and 0.40/month among n = 44 sham participants, P = 0.6), similar LH to FSH ratio improvement (-0.5 and -0.8 true and sham, respectively, P < 0.04 after intervention vs. baseline) and a similar decline in LH over the 5-month protocol (P < 0.05). Neither arm experienced a change in FSH. There were seven pregnancies (no difference by intervention, P = 0.7). Lower fasting insulin and free testosterone were highly correlated with a higher ovulation rate within the true acupuncture group only (P = 0.03), controlling for prestudy menstrual frequency and body mass index. We were unable to discern a difference between the true and sham acupuncture protocols for these women with PCOS, and both groups had a similar improvement in their LH/FSH ratio.
Fouda, Usama M; Sayed, Ahmed M
2011-12-01
To compare the efficacy and cost-effectiveness of extended high dose letrozole regimen/HPuFSH-gonadotropin releasing hormone antagonist (GnRHant) protocol with short low dose letrozole regimen/HPuFSH-GnRHant protocol in poor responders undergoing IVF-ET. In this randomized controlled trial, 136 women who responded poorly to GnRH agonist long protocol in their first IVF cycle were randomized into two equal groups using computer generated list and were treated in the second IVF cycle by either extended letrozole regimen (5 mg/day during the first 5 days of cycle and 2.5 mg/day during the subsequent 3 days) combined with HPuFSH-GnRHant protocol or short letrozole regimen (2.5 mg/day from cycle day 3-7) combined with HPuFSH-GnRHant protocol. There were no significant differences between both groups with regard to number of oocytes retrieved and clinical pregnancy rate (5.39 ± 2.08 vs. 5.20 ± 1.88 and 22.06% vs. 16.18%, respectively).The total gonadotropins dose and medications cost per cycle were significantly lower in extended letrozole group (44.87 ± 9.16 vs. 59.97 ± 14.91 ampoules and 616.52 ± 94.97 vs. 746.84 ± 149.21 US Dollars ($), respectively).The cost-effectiveness ratio was 2794 $ in extended letrozole group and 4616 $ in short letrozole group. Extended letrozole regimen/HPuFSH-GnRHant protocol was more cost-effective than short letrozole regimen/HPuFSH-GnRHant protocol in poor responders undergoing IVF-ET.
Zarzycki, Paweł K; Portka, Joanna K
2015-09-01
Pentacyclic triterpenoids, particularly hopanoids, are organism-specific compounds and are generally considered as useful biomarkers that allow fingerprinting and classification of biological, environmental and geological samples. Simultaneous quantification of various hopanoids together with battery of related non-polar and low-molecular mass compounds may provide principal information for geochemical and environmental research focusing on both modern and ancient investigations. Target compounds can be derived from microbial biomass, water columns, sediments, coals, crude fossils or rocks. This create number of analytical problems due to different composition of the analytical matrix and interfering compounds and therefore, proper optimization of quantification protocols for such biomarkers is still the challenge. In this work we summarizing typical analytical protocols that were recently applied for quantification of hopanoids like compounds from different samples. Main steps including components of interest extraction, pre-purification, fractionation, derivatization and quantification involving gas (1D and 2D) as well as liquid separation techniques (liquid-liquid extraction, solid-phase extraction, planar and low resolution column chromatography, high-performance liquid chromatography) are described and discussed from practical point of view, mainly based on the experimental papers that were published within last two years, where significant increase in hopanoids research was noticed. The second aim of this review is to describe the latest research trends concerning determination of hopanoids and related low-molecular mass lipids analyzed in various samples including sediments, rocks, coals, crude oils and plant fossils as well as stromatolites and microbial biomass cultivated under different conditions. It has been found that majority of the most recent papers are based on uni- or bivariate approach for complex data analysis. Data interpretation involves number of physicochemical parameters and hopanoids quantities or given biomarkers mass ratios derived from high-throughput separation and detection systems, typically GC-MS and HPLC-MS. Based on quantitative data reported in recently published experimental works it has been demonstrated that multivariate data analysis using e.g. principal components computations may significantly extend our knowledge concerning proper biomarkers selection and samples classification by means of hopanoids and related non-polar compounds. Copyright © 2015 Elsevier Ltd. All rights reserved.
Bebko, Serge P; Green, David M; Awad, Samir S
2015-05-01
Surgical site infections (SSIs), commonly caused by methicillin-resistant Staphylococcus aureus (MRSA), are associated with significant morbidity and mortality, specifically when hardware is implanted in the patient. Previously, we have demonstrated that a preoperative decontamination protocol using chlorhexidine gluconate washcloths and intranasal antiseptic ointment is effective in eradicating MRSA in the nose and on the skin of patients. To examine the effect of a decontamination protocol on SSIs in patients undergoing elective orthopedic surgery with hardware implantation. A prospective database of patients undergoing elective orthopedic surgery with hardware implantation at the Michael E. DeBakey Veterans Affairs Medical Center in Houston, Texas, was analyzed from October 1, 2012, to December 31, 2013. Cohort groups before and after the intervention were compared. Starting in May 2013, during their preoperative visit, all of the patients watched an educational video about MRSA decontamination and were given chlorhexidine washcloths and oral rinse and nasal povidone-iodine solution to be used the night before and the morning of scheduled surgery. Thirty-day SSI rates were collected according to the definitions of the Centers for Disease Control and Prevention National Nosocomial Infections Surveillance. Data on demographics, comorbidities such as chronic obstructive pulmonary disease and coronary artery disease, tobacco use, alcohol use, and body mass index were also collected. Univariate analysis was performed between the 2 groups of patients. Multivariate analysis was used to identify independent predictors of SSI. A total of 709 patients were analyzed (344 controls and 365 patients who were decolonized). Both groups were well matched with no significant differences in age, body mass index, sex, or comorbidities. All of the patients (100%) completed the MRSA decontamination protocol. The SSI rate in the intervention group was significantly lower (1.1%; 4 of 365 patients developed an SSI) than the SSI rate in the control group (3.8%; 13 of 344 patients developed an SSI) (P = .02). Multivariate logistic regression identified MRSA decontamination as an independent predictor of not developing an SSI (adjusted odds ratio, 0.24 [95% CI, 0.08-0.77]; P = .02). Our study demonstrates that preoperative MRSA decontamination with chlorhexidine washcloths and oral rinse and intranasal povidone-iodine decreased the SSI rate by more than 50% among patients undergoing elective orthopedic surgery with hardware implantation. Universal decontamination using this low-cost protocol may be considered as an additional prevention strategy for SSIs in patients undergoing orthopedic surgery with hardware implantation and warrants further study.
Behbehani, Gregory K.; Thom, Colin; Zunder, Eli R.; Finck, Rachel; Gaudilliere, Brice; Fragiadakis, Gabriela K.; Fantl, Wendy J.; Nolan, Garry P.
2015-01-01
Fluorescent cellular barcoding and mass-tag cellular barcoding are cytometric methods that enable high sample throughput, minimize inter-sample variation, and reduce reagent consumption. Previously employed barcoding protocols require that barcoding be performed after surface marker staining, complicating combining the technique with measurement of alcohol-sensitive surface epitopes. This report describes a method of barcoding fixed cells after a transient partial permeabilization with 0.02% saponin that results in efficient and consistent barcode staining with fluorescent or mass-tagged reagents while preserving surface marker staining. This approach simplifies barcoding protocols and allows direct comparison of surface marker staining of multiple samples without concern for variations in the antibody cocktail volume, antigen-antibody ratio, or machine sensitivity. Using this protocol, cellular barcoding can be used to reliably detect subtle differences in surface marker expression. PMID:25274027
OSI-compatible protocols for mobile-satellite communications: The AMSS experience
NASA Technical Reports Server (NTRS)
Moher, Michael
1990-01-01
The protocol structure of the international aeronautical mobile satellite service (AMSS) is reviewed with emphasis on those aspects of protocol performance, validation, and conformance which are peculiar to mobile services. This is in part an analysis of what can be learned from the AMSS experience with protocols which is relevant to the design of other mobile satellite data networks, e.g., land mobile.
Protocol Analysis: A Methodology for Exploring the Information Processing of Gifted Students.
ERIC Educational Resources Information Center
Anderson, Margaret A.
1986-01-01
Protocol analysis techniques, in which subjects are taught to think aloud, can provide information on the mental operations used by gifted learners. Concerns over the use of such data are described and new directions for the technique are proposed. (CL)
MASTER ANALYTICAL SCHEME FOR ORGANIC COMPOUNDS IN WATER: PART 1. PROTOCOLS
A Master Analytical Scheme (MAS) has been developed for the analysis of volatile (gas chromatographable) organic compounds in water. In developing the MAS, it was necessary to evaluate and modify existing analysis procedures and develop new techniques to produce protocols that pr...
Suntharalingam, Saravanabavaan; Mikat, Christian; Wetter, Axel; Guberina, Nika; Salem, Ahmed; Heil, Philipp; Forsting, Michael; Nassenstein, Kai
2018-06-01
The aim of this study was to investigate the radiation dose and image quality of a whole-body low-dose CT (WBLDCT) using spectral shaping at 100 kV (Sn 100 kV) for the assessment of osteolytic lesions in patients with multiple myeloma. Thirty consecutive patients were retrospectively selected, who underwent a WBLDCT on a third-generation dual-source CT (DSCT) (Sn 100 kV, ref. mAs: 130). They were matched with patients, who were examined on a second-generation DSCT with a standard low-dose protocol (100 kV, ref. mAs: 111). Objective and subjective image quality, radiation exposure as well as the frequency of osteolytic lesions were evaluated. All scans were of diagnostic image quality. Subjective overall image quality was significantly higher in the study group (p = 0.0003). Objective image analysis revealed that signal intensities, signal-to-noise ratio and contrast-to-noise ratio of the bony structures were equal or significantly higher in the control group. There was no significant difference in the frequency of osteolytic lesions (p = 0.259). The median effective dose of the study protocol was significantly lower (1.45 mSv vs. 5.65 mSv; p < 0.0001). WBLDCT with Sn 100 kV can obtain sufficient image quality for the depiction of osteolytic lesions while reducing the radiation dose by approximately 74%. • Spectral shaping using tin filtration is beneficial for whole-body low-dose CT • Sn 100 kV yields sufficient image quality for depiction of osteolytic lesions • Whole-body low-dose CT can be performed with a median dose of 1.5 mSv.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, David L., E-mail: david.schwartz@utsw.edu; Harris, Jonathan; Yao, Min
2015-03-15
Purpose: To evaluate candidate fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) imaging biomarkers for head-and-neck chemoradiotherapy outcomes in the cooperative group trial setting. Methods and Materials: Radiation Therapy Oncology Group (RTOG) protocol 0522 patients consenting to a secondary FDG-PET/CT substudy were serially imaged at baseline and 8 weeks after radiation. Maximum standardized uptake value (SUVmax), SUV peak (mean SUV within a 1-cm sphere centered on SUVmax), and metabolic tumor volume (MTV) using 40% of SUVmax as threshold were obtained from primary tumor and involved nodes. Results: Of 940 patients entered onto RTOG 0522, 74 were analyzable for this substudy. Neither high baselinemore » SUVmax nor SUVpeak from primary or nodal disease were associated with poor treatment outcomes. However, primary tumor MTV above the cohort median was associated with worse local-regional control (hazard ratio 4.01, 95% confidence interval 1.28-12.52, P=.02) and progression-free survival (hazard ratio 2.34, 95% confidence interval 1.02-5.37, P=.05). Although MTV and T stage seemed to correlate (mean MTV 6.4, 13.2, and 26.8 for T2, T3, and T4 tumors, respectively), MTV remained a strong independent prognostic factor for progression-free survival in bivariate analysis that included T stage. Primary MTV remained prognostic in p16-associated oropharyngeal cancer cases, although sample size was limited. Conclusion: High baseline primary tumor MTV was associated with worse treatment outcomes in this limited patient subset of RTOG 0522. Additional confirmatory work will be required to validate primary tumor MTV as a prognostic imaging biomarker for patient stratification in future trials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kail, Brian W; Link, Dirk D; Morreale, Bryan D
A method for selectively determining both free fatty acids (FFA) and triacylglycerides (TAGs) in biological oils was investigated and optimized using gas chromatography after esterification of the target species to their corresponding fatty acid methyl esters (FAMEs). The method used acid catalyzed esterification in methanolic solutions under conditions of varying severity to achieve complete conversion of more reactive FFAs while preserving the concentration of TAGs. Complete conversion of both free acids and glycerides to corresponding FAMEs was found to require more rigorous reaction conditions involving heating to 120°C for up to 2 h. Method validation was provided using gas chromatography–flamemore » ionization detection, gas chromatography–mass spectrometry, and liquid chromatography–mass spectrometry. The method improves on existing methods because it allows the total esterified lipid to be broken down by FAMEs contributed by FFA compared to FAMEs from both FFA and TAGs. Single and mixed-component solutions of pure fatty acids and triglycerides, as well as a sesame oil sample to simulate a complex biological oil, were used to optimize the methodologies. Key parameters that were investigated included: HCl-to-oil ratio, temperature and reaction time. Pure free fatty acids were found to esterify under reasonably mild conditions (10 min at 50°C with a 2.1:1 HCl to fatty acid ratio) with 97.6 ± 2.3% recovery as FAMEs, while triglycerides were largely unaffected under these reaction conditions. The optimized protocol demonstrated that it is possible to use esterification reactions to selectively determine the free acid content, total lipid content, and hence, glyceride content in biological oils. This protocol also allows gas chromatography analysis of FAMEs as a more ideal analyte than glyceride species in their native state.« less
Creatinine reduction ratio: a useful marker to identify medium and high-risk renal transplants.
Vilar, Enric; Varagunam, Mira; Yaqoob, Muhammad M; Raftery, Martin; Thuraisingham, Raj
2010-01-15
Delayed graft function (DGF) has a major impact on long-term renal transplant survival. However, it is a diagnosis made retrospectively with little opportunity to modify treatment protocols. A classification based on creatinine reduction ratio between days 1 and 2 (CRR2) suggests that patients with CRR2 less than or equal to 30% (nondialysis requiring DGF [ND-DGF]) have similar outcomes to those with dialysis-requiring delayed graft function (D-DGF). We retrospectively applied this definition in our cohort of patients to examine outcomes. We studied the association between CRR2 and graft outcomes in all 367 patients transplanted between 1996 and 2004 at our center. Patients were divided into the following three groups: IGF (immediate graft function; CRR2 >30%), D-DGF, and ND-DGF. Mean follow-up was 4.2 years. IGF accounted for 36% of patients, D-DGF for 22%, and ND-DGF for 42%. CRR2 was inversely correlated with serum creatinine on days 7, 30, 90, and 365 (r ranging from -0.65 to -0.22, P<0.001). Graft survival at 5 years was 98% (IGF), 74% (D-DGF), and 89% (ND-DGF). There was a significant difference in graft survival between IGF and D-DGF (P<0.001) and IGF and ND-DGF (P=0.005). In a multivariate analysis adjusting for recipient age and sex, donor age and sex, and human leukocyte antigen mismatch, graft failure was 2.4 times more likely to occur in patients with D-DGF than those with ND-DGF(P=0.02). Our study shows CRR2 influences long-term graft outcomes. Unlike the original description, patients with ND-DGF carry an intermediate risk and perhaps should be considered on day 2 for alternative treatment protocols.
Jay D. Miller; Eric E. Knapp; Carl H. Key; Carl N. Skinner; Clint J. Isbell; R. Max Creasy; Joseph W. Sherlock
2009-01-01
Multispectral satellite data have become a common tool used in the mapping of wildland fire effects. Fire severity, defined as the degree to which a site has been altered, is often the variable mapped. The Normalized Burn Ratio (NBR) used in an absolute difference change detection protocol (dNBR), has become the remote sensing method of choice for US Federal land...
Global Monitoring of Clouds and Aerosols Using a Network of Micro-Pulse Lidar Systems
NASA Technical Reports Server (NTRS)
Welton, Ellsworth J.; Campbell, James R.; Spinhirne, James D.; Scott, V. Stanley
2000-01-01
Long-term global radiation programs, such as AERONET and BSRN, have shown success in monitoring column averaged cloud and aerosol optical properties. Little attention has been focused on global measurements of vertically resolved optical properties. Lidar systems are the preferred instrument for such measurements. However, global usage of lidar systems has not been achieved because of limits imposed by older systems that were large, expensive, and logistically difficult to use in the field. Small, eye-safe, and autonomous lidar systems are now currently available and overcome problems associated with older systems. The first such lidar to be developed is the Micro-pulse lidar System (MPL). The MPL has proven to be useful in the field because it can be automated, runs continuously (day and night), is eye-safe, can easily be transported and set up, and has a small field-of-view which removes multiple scattering concerns. We have developed successful protocols to operate and calibrate MPL systems. We have also developed a data analysis algorithm that produces data products such as cloud and aerosol layer heights, optical depths, extinction profiles, and the extinction-backscatter ratio. The algorithm minimizes the use of a priori assumptions and also produces error bars for all data products. Here we present an overview of our MPL protocols and data analysis techniques. We also discuss the ongoing construction of a global MPL network in conjunction with the AERONET program. Finally, we present some early results from the MPL network.
NASA Technical Reports Server (NTRS)
Loftin, K. C.; Conkin, J.; Powell, M. R.
1997-01-01
BACKGROUND: Several previous studies indicated that exercise during prebreathe with 100% O2 decreased the incidence of hypobaric decompression sickness (DCS). We report a meta-analysis of these investigations combined with a new study in our laboratory to develop a statistical model as a predictive tool for DCS. HYPOTHESIS: Exercise during prebreathe increases N2 elimination in a theoretical 360-min half-time compartment decreasing the incidence of DCS. METHODS: A dose-response probability tissue ratio (TR) model with 95% confidence limits was created for two groups, prebreathe with exercise (n = 113) and resting prebreathe (n = 113), using nonlinear regression analysis with maximum likelihood optimization. RESULTS: The model predicted that prebreathe exercise would reduce the residual N2 in a 360-min half-time compartment to a level analogous to that in a 180-min compartment. This finding supported the hypothesis. The incidence of DCS for the exercise prebreathe group was significantly decreased (Chi-Square = 17.1, p < 0.0001) from the resting prebreathe group. CONCLUSIONS: The results suggested that exercise during prebreathe increases tissue perfusion and N2 elimination approximately 2-fold and markedly lowers the risk of DCS. Based on the model, the prebreathe duration may be reduced from 240 min to a predicted 91 min for the protocol in our study, but this remains to be verified. The model provides a useful planning tool to develop and test appropriate prebreathe exercise protocols and to predict DCS risks for astronauts.
Sinha, Rajesh; Kumar Ojha, Amit; Sarangi, Soumendra; Nair, Nirmala; Tripathy, Prasanta; Sachdev, H S; Bhattacharyya, Sanghita; Gope, Rajkumar; Rath, Shibanand; Rath, Suchitra; Srivastava, Aradhana; Pulkki-Brännström, Anni-Maria; Costello, Anthony; Copas, Andrew; Saville, Naomi; Prost, Audrey; Haghparast-Bidgoli, Hassan
2016-01-01
Introduction Undernutrition affects ∼165 million children globally and contributes up to 45% of all child deaths. India has the highest proportion of global undernutrition-related morbidity and mortality. This protocol describes the planned economic evaluation of a community-based intervention to improve growth in children under 2 years of age in two rural districts of eastern India. The intervention is being evaluated through a cluster-randomised controlled trial (cRCT, the CARING trial). Methods and analysis A cost-effectiveness and cost–utility analysis nested within a cRCT will be conducted from a societal perspective, measuring programme, provider, household and societal costs. Programme costs will be collected prospectively from project accounts using a standardised tool. These will be supplemented with time sheets and key informant interviews to inform the allocation of joint costs. Direct and indirect costs incurred by providers will be collected using key informant interviews and time use surveys. Direct and indirect household costs will be collected prospectively, using time use and consumption surveys. Incremental cost-effectiveness ratios (ICERs) will be calculated for the primary outcome measure, that is, cases of stunting prevented, and other outcomes such as cases of wasting prevented, cases of infant mortality averted, life years saved and disability-adjusted life years (DALYs) averted. Sensitivity analyses will be conducted to assess the robustness of results. Ethics and dissemination There is a shortage of robust evidence regarding the cost-effectiveness of strategies to improve early child growth. As this economic evaluation is nested within a large scale, cRCT, it will contribute to understanding the fiscal space for investment in early child growth, and the relative (in)efficiency of prioritising resources to this intervention over others to prevent stunting in this and other comparable contexts. The protocol has all necessary ethical approvals and the findings will be disseminated within academia and the wider policy sphere. Trial registration number ISRCTN51505201; pre-results. PMID:27807084
2012-01-01
Background Clinical Practice Guidelines recommend using peripheral blood pulse measuring as a screening test for Atrial Fibrillation. However, there is no adequate evidence supporting the efficacy of such procedure in primary care clinical practice. This paper describes a study protocol designed to verify whether early opportunistic screening for Atrial Fibrillation by measuring blood pulse is more effective than regular practice in subjects aged 65 years attending primary care centers. Methods/design An cluster-randomized controlled trial conducted in Primary Care Centers of the Spanish National Health Service. A total of 269 physicians and nurses will be allocated to one of the two arms of the trial by stratified randomization with a 3:2 ratio (three practitioners will be assigned to the Control Group for every two practitioners assigned to the Experimental Group). As many as 12 870 patients aged 65 years or older and meeting eligibility criteria will be recruited (8 580 will be allocated to the Experimental Group and 4 290 to the Control Group). Randomization and allocation to trial groups will be carried out by a central computer system. The Experimental Group practitioners will conduct an opportunistic case finding for patients with Atrial Fibrillation, while the Control Group practitioners will follow the regular guidelines. The first step will be finding new Atrial Fibrillation cases. A descriptive inferential analysis will be performed (bivariate and multivariate by multilevel logistic regression analysis). Discussion If our hypothesis is confirmed, we expect Primary Care professionals to take a more proactive approach and adopt a new protocol when a patient meeting the established screening criteria is identified. Finally, we expect this measure to be incorporated into Clinical Practice Guidelines. Trial registration The study is registered as NCT01291953 (ClinicalTrials.gob) PMID:23130754
Wang, Yao; Sokhadze, Estate M.; El-Baz, Ayman S.; Li, Xiaoli; Sears, Lonnie; Casanova, Manuel F.; Tasman, Allan
2016-01-01
Neurofeedback is a mode of treatment that is potentially useful for improving self-regulation skills in persons with autism spectrum disorder. We proposed that operant conditioning of EEG in neurofeedback mode can be accompanied by changes in the relative power of EEG bands. However, the details on the change of the relative power of EEG bands during neurofeedback training course in autism are not yet well explored. In this study, we analyzed the EEG recordings of children diagnosed with autism and enrolled in a prefrontal neurofeedback treatment course. The protocol used in this training was aimed at increasing the ability to focus attention, and the procedure represented the wide band EEG amplitude suppression training along with upregulation of the relative power of gamma activity. Quantitative EEG analysis was completed for each session of neurofeedback using wavelet transform to determine the relative power of gamma and theta/beta ratio, and further to detect the statistical changes within and between sessions. We found a linear decrease of theta/beta ratio and a liner increase of relative power of gamma activity over 18 weekly sessions of neurofeedback in 18 high functioning children with autism. The study indicates that neurofeedback is an effective method for altering EEG characteristics associated with the autism spectrum disorder. Also, it provides information about specific changes of EEG activities and details the correlation between changes of EEG and neurofeedback indexes during the course of neurofeedback. This pilot study contributes to the development of more effective approaches to EEG data analysis during prefrontal neurofeedback training in autism. PMID:26834615
Cipryan, Lukas
2017-02-01
The aim of this study was to investigate changes of interleukin-6 (IL-6), total antioxidant capacity (TAC) and muscle damage markers (creatine kinase (CK), myoglobin and lactate dehydrogenase (LDH)) in response to three different high-intensity interval training (HIIT) protocols of identical external work. Twelve moderately-trained males participated in the three HIIT trials which consisted of a warm-up, followed by 12 min of 15 s, 30 s or 60 s HIIT sequences with the work/rest ratio 1. The biochemical markers of inflammation, oxidative stress and muscle damage were analysed POST, 3 h and 24 h after the exercise. All HIIT protocols caused an immediate increase in IL-6, TAC, CK, myoglobin and LDH. The most pronounced between-trials differences were found for the POST-exercise changes in IL-6 (Effect size ± 90% confidence interval: 1.51 ± 0.63, 0.84 ± 0.34 and 1.80 ± 0.60 for the 15s/15s, 30s/30s and 60s/60s protocol, respectively) and myoglobin (1.11 ± 0.29, 0.45 ± 0.48 and 1.09 ± 0.22 for the 15s/15s, 30s/30s and 60s/60s protocol, respectively). There were no substantial between-trial differences in other biochemical variables. In conclusion, the 15s/15s and 60s/60s protocols might be preferred to the 30s/30s protocols in order to maximize the training stimulus.
Steinbacher, M; Vollmer, M K; Buchmann, B; Reimann, S
2008-03-01
A combination of reconstructed histories, long-term time series and recent quasi-continuous observations of non-CO2 greenhouse gases at the high-Alpine site Jungfraujoch is used to assess their current global radiative forcing budget and the influence of regulations due to the Montreal Protocol on Substances that Deplete the Ozone Layer in terms of climate change. Extrapolated atmospheric greenhouse gases trends from 1989 assuming a business-as-usual scenario, i.e. no Montreal Protocol restriction, are presented and compared to the observations. The largest differences between hypothetical business-as-usual mixing ratios and current atmospheric observations over the last 16 years were found for chlorinated species, in particular methyl chloroform (CH3CCl3) at 167 to 203 ppt and chlorofluorocarbon-12 (CFC-12) at 121 to 254 ppt. These prevented increases were used to estimate the effects of their restrictions on the radiative forcing budget. The net direct effect due to the Montreal Protocol regulations reduces global warming and offsets about 14 to 30% of the positive greenhouse effect related to the major greenhouse gases CO2, CH4, N2O and also SF6, and about 12 to 22% of the hypothetical current radiative forcing increase without Montreal Protocol restrictions. Thus, the Montreal Protocol succeeded not only in reducing the atmospheric chlorine content in the atmosphere but also dampened global warming. Nevertheless, the Montreal Protocol controlled species still add to global warming.
Wang, Xiaojie; Zheng, Hong; Shou, Tao; Tang, Chunming; Miao, Kun; Wang, Ping
2017-03-29
Osteosarcoma is the most common malignant bone tumour. Due to the high metastasis rate and drug resistance of this disease, multi-drug regimens are necessary to control tumour cells at various stages of the cell cycle, eliminate local or distant micrometastases, and reduce the emergence of drug-resistant cells. Many adjuvant chemotherapy protocols have shown different efficacies and controversial results. Therefore, we classified the types of drugs used for adjuvant chemotherapy and evaluated the differences between single- and multi-drug chemotherapy regimens using network meta-analysis. We searched electronic databases, including PubMed (MEDLINE), EmBase, and the Cochrane Library, through November 2016 using the keywords "osteosarcoma", "osteogenic sarcoma", "chemotherapy", and "random*" without language restrictions. The major outcome in the present analysis was progression-free survival (PFS), and the secondary outcome was overall survival (OS). We used a random effect network meta-analysis for mixed multiple treatment comparisons. We included 23 articles assessing a total of 5742 patients in the present systematic review. The analysis of PFS indicated that the T12 protocol (including adriamycin, bleomycin, cyclophosphamide, dactinomycin, methotrexate, cisplatin) plays a more critical role in osteosarcoma treatment (surface under the cumulative ranking (SUCRA) probability 76.9%), with a better effect on prolonging the PFS of patients when combined with ifosfamide (94.1%) or vincristine (81.9%). For the analysis of OS, we separated the regimens to two groups, reflecting the disconnection. The T12 protocol plus vincristine (94.7%) or the removal of cisplatinum (89.4%) is most likely the best regimen. We concluded that multi-drug regimens have a better effect on prolonging the PFS and OS of osteosarcoma patients, and the T12 protocol has a better effect on prolonging the PFS of osteosarcoma patients, particularly in combination with ifosfamide or vincristine. The OS analysis showed that the T12 protocol plus vincristine or the T12 protocol with the removal of cisplatinum might be a better regimen for improving the OS of patients. However, well-designed randomized controlled trials of chemotherapeutic protocols are still necessary.
ERIC Educational Resources Information Center
Monroe, Steven D.
2012-01-01
The purpose of this study was to explore how the use of video in the cognitive task analysis (CTA) retrospective verbal protocol analysis (RVPA) during a job analysis affects: (a) the quality of performing the CTA, (b) the time to complete the CTA, and (c) the cost to execute the CTA. Research has shown when using the simultaneous VPA during a CTA…
A novel assay system for macrophage-activating factor activity using a human U937 cell line.
Ishikawa, Mami; Inoue, Takahiro; Inui, Toshio; Kuchiike, Daisuke; Kubo, Kentaro; Uto, Yoshihiro; Nishikata, Takahito
2014-08-01
Macrophages play important roles in antitumor immunity, and immunotherapy with the group-specific component protein-derived macrophage-activating factor (GcMAF) has been reported to be effective in patients with various types of cancers. However, in macrophage research, it is important to properly evaluate macrophage activity. U937 macrophages were induced by 12-O-tetradecanoyl-13-phorbolacetate (TPA). The phagocytic activity of macrophages was evaluated as the internalized beads ratio. The MAF activity was assessed at 30 min after MAF addition as the activation ratio. We established a novel assay for phagocytic activities using differentiated U937 macrophages. The novel protocol was simple and rapid and was sensitive for GcMAF. This protocol should be useful not only for basic studies, such as those on molecular mechanisms underlying macrophage activation, but also for clinical studies, such as assessment of GcMAF activity prior to clinical use. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Srivastava, Saurabh Kumar; Singh, Sandeep Kumar; Suri, Jasjit S
2018-04-13
A machine learning (ML)-based text classification system has several classifiers. The performance evaluation (PE) of the ML system is typically driven by the training data size and the partition protocols used. Such systems lead to low accuracy because the text classification systems lack the ability to model the input text data in terms of noise characteristics. This research study proposes a concept of misrepresentation ratio (MRR) on input healthcare text data and models the PE criteria for validating the hypothesis. Further, such a novel system provides a platform to amalgamate several attributes of the ML system such as: data size, classifier type, partitioning protocol and percentage MRR. Our comprehensive data analysis consisted of five types of text data sets (TwitterA, WebKB4, Disease, Reuters (R8), and SMS); five kinds of classifiers (support vector machine with linear kernel (SVM-L), MLP-based neural network, AdaBoost, stochastic gradient descent and decision tree); and five types of training protocols (K2, K4, K5, K10 and JK). Using the decreasing order of MRR, our ML system demonstrates the mean classification accuracies as: 70.13 ± 0.15%, 87.34 ± 0.06%, 93.73 ± 0.03%, 94.45 ± 0.03% and 97.83 ± 0.01%, respectively, using all the classifiers and protocols. The corresponding AUC is 0.98 for SMS data using Multi-Layer Perceptron (MLP) based neural network. All the classifiers, the best accuracy of 91.84 ± 0.04% is shown to be of MLP-based neural network and this is 6% better over previously published. Further we observed that as MRR decreases, the system robustness increases and validated by standard deviations. The overall text system accuracy using all data types, classifiers, protocols is 89%, thereby showing the entire ML system to be novel, robust and unique. The system is also tested for stability and reliability.
NASA Technical Reports Server (NTRS)
Clare, L. P.; Yan, T.-Y.
1985-01-01
The analysis of the ALOHA random access protocol for communications channels with fading is presented. The protocol is modified to send multiple contiguous copies of a message at each transmission attempt. Both pure and slotted ALOHA channels are considered. A general two state model is used for the channel error process to account for the channel fading memory. It is shown that greater throughput and smaller delay may be achieved using repetitions. The model is applied to the analysis of the delay-throughput performance in a fading mobile communications environment. Numerical results are given for NASA's Mobile Satellite Experiment.
Rethinking Protocol Analysis from a Cultural Perspective.
ERIC Educational Resources Information Center
Smagorinsky, Peter
2001-01-01
Outlines a cultural-historical activity theory (CHAT) perspective that accounts for protocol analysis along three key dimensions: the relationship between thinking and speech from a representational standpoint; the social role of speech in research methodology; and the influence of speech on thinking and data collection. (Author/VWL)
MASTER ANALYTICAL SCHEME FOR ORGANIC COMPOUNDS IN WATER. PART 2. APPENDICES TO PROTOCOLS
A Master Analytical Scheme (MAS) has been developed for the analysis of volatile (gas chromatographable) organic compounds in water. In developing the MAS, it was necessary to evaluate and modify existing analysis procedures and develop new techniques to produce protocols that pr...
Pinkerton, Steven D.; Pearson, Cynthia R.; Eachus, Susan R.; Berg, Karina M.; Grimes, Richard M.
2008-01-01
Summary Maximizing our economic investment in HIV prevention requires balancing the costs of candidate interventions against their effects and selecting the most cost-effective interventions for implementation. However, many HIV prevention intervention trials do not collect cost information, and those that do use a variety of cost data collection methods and analysis techniques. Standardized cost data collection procedures, instrumentation, and analysis techniques are needed to facilitate the task of assessing intervention costs and to ensure comparability across intervention trials. This article describes the basic elements of a standardized cost data collection and analysis protocol and outlines a computer-based approach to implementing this protocol. Ultimately, the development of such a protocol would require contributions and “buy-in” from a diverse range of stakeholders, including HIV prevention researchers, cost-effectiveness analysts, community collaborators, public health decision makers, and funding agencies. PMID:18301128
Song, Jun; Braun, Gordon; Bevis, Eric; Doncaster, Kristen
2006-08-01
Fruit tissues are considered recalcitrant plant tissue for proteomic analysis. Three phenol-free protein extraction procedures for 2-DE were compared and evaluated on apple fruit proteins. Incorporation of hot SDS buffer, extraction with TCA/acetone precipitation was found to be the most effective protocol. The results from SDS-PAGE and 2-DE analysis showed high quality proteins. More than 500 apple polypeptides were separated on a small scale 2-DE gel. The successful protocol was further tested on banana fruit, in which 504 and 386 proteins were detected in peel and flesh tissues, respectively. To demonstrate the quality of the extracted proteins, several protein spots from apple and banana peels were cut from 2-DE gels, analyzed by MS and have been tentatively identified. The protocol described in this study is a simple procedure which could be routinely used in proteomic studies of many types of recalcitrant fruit tissues.
Imahiyerobo, Thomas A.; Liang, Fan; Fahradyan, Artur; Urbinelli, Leo; Lau, Jennifer; Matar, Marla; Magee, William; Urata, Mark
2017-01-01
Background: The optimal timing for cleft lip repair has yet to be established. Advances in neonatal anesthesia, along with a growing body of literature, suggesting benefits of earlier cleft lip and nasal repair, have set the stage for a reexamination of current practices. Methods: In this prospective study, cleft lip and nasal repair occurred on average at 34.8 days (13–69 days). Nasal correction was achieved primarily through molding the nasal cartilage without the placement of nasal sutures at the time of repair. A standardized anesthetic protocol aimed at limiting neurotoxicity was utilized in all cases. Anesthetic and postoperative complications were assessed. A 3-dimensional nasal analysis compared pre- and postoperative nasal symmetry for unilateral clefts. Surveys assessed familial response to repair. Results: Thirty-two patients were included (27 unilateral and 5 bilateral clefts). In this study, the overall complication rate was 3.1%. Anthropometric measurements taken from 3-dimensional-image models showed statistically significant improvement in ratios of nostril height (preoperative mean, 0.59; postoperative mean, 0.80), nasal base width (preoperative mean, 1.96; postoperative mean, 1.12), columella length (preoperative mean, 0.62; postoperative mean, 0.89; and columella angle (preoperative mean, 30.73; postoperative mean, 9.1). Survey data indicated that families uniformly preferred earlier repair. Conclusions: We present evidence that early cleft lip and nasal repair can be performed safely and is effective at improving nasal symmetry without the placement of any nasal sutures. Utilization of this protocol has the potential to be a paradigm shift in the treatment of cleft lip and nasal deformity. PMID:28740766
Golestani, Mina; Eshghi, Peyman; Rasekh, Hamid Reza; Cheraghali, Abdoll Majid; Salamzadeh, Jamshid; Naderi, Majid; Managhchi, Mohammad Reza; Hoorfar, Hamid; Toogeh, Gholam Reza; Imani, Ali; Khodayari, Mohammad Taghi; Habibpanah, Behnaz; Hantooshzadeh, Razieh
2016-01-01
Nowadays, bypassing agents such as recombinant activated factor VII (rFVIIa) and activated prothrombin complex concentrates (aPCC) are used to treat bleeding episodes in the Hemophilia patients with inhibitors. AryoSeven® is an Iranian biogeneric rFVIIa with homogeneity of efficacy and the nature to NovoSeven in a comparative trial. The current clinical trial aimed to evaluate the cost-effectiveness of FEIBA and AryoSeven® by Decision Analytic Model according to the Iranian healthcare system. An open label, multi-center, cross-over clinical trial was designed. Patients were categorized into 3 groups based on their prior tendency to one or none of the products. To determine the premium therapeutic strategy, the Incremental cost-effectiveness ratio (ICER) was calculated. Protocol F led to more treatment success in group F than the other groups (P= 0.03). Also, there was a significant statistical difference between the mean of effectiveness scores in the groups using protocol F (P = 0.01). The effectiveness of protocol F and A were 89% and 72%, respectively. ICER cost US$ to manage an episode of bleeding to get one more unit of effectiveness using FEIBA VS. AryoSeven. Although the results showed that AryoSeven was more cost-effective compared to FEIBA, the two strategies were undominated. In other words, both medicines can be applied in the first line of the treatment if the cost of FEIBA was reduced. The present clinical trial was registered at IRCT website, under ID No.2013020612380N1.
High throughput film dosimetry in homogeneous and heterogeneous media for a small animal irradiator
Wack, L.; Ngwa, W.; Tryggestad, E.; Tsiamas, P.; Berbeco, R.; Ng, S.K.; Hesser, J.
2013-01-01
Purpose We have established a high-throughput Gafchromic film dosimetry protocol for narrow kilo-voltage beams in homogeneous and heterogeneous media for small-animal radiotherapy applications. The kV beam characterization is based on extensive Gafchromic film dosimetry data acquired in homogeneous and heterogeneous media. An empirical model is used for parameterization of depth and off-axis dependence of measured data. Methods We have modified previously published methods of film dosimetry to suit the specific tasks of the study. Unlike film protocols used in previous studies, our protocol employs simultaneous multichannel scanning and analysis of up to nine Gafchromic films per scan. A scanner and background correction were implemented to improve accuracy of the measurements. Measurements were taken in homogeneous and inhomogeneous phantoms at 220 kVp and a field size of 5 × 5 mm2. The results were compared against Monte Carlo simulations. Results Dose differences caused by variations in background signal were effectively removed by the corrections applied. Measurements in homogeneous phantoms were used to empirically characterize beam data in homogeneous and heterogeneous media. Film measurements in inhomogeneous phantoms and their empirical parameterization differed by about 2%–3%. The model differed from MC by about 1% (water, lung) to 7% (bone). Good agreement was found for measured and modelled off-axis ratios. Conclusions EBT2 films are a valuable tool for characterization of narrow kV beams, though care must be taken to eliminate disturbances caused by varying background signals. The usefulness of the empirical beam model in interpretation and parameterization of film data was demonstrated. PMID:23510532
Auditory-Perceptual and Acoustic Methods in Measuring Dysphonia Severity of Korean Speech.
Maryn, Youri; Kim, Hyung-Tae; Kim, Jaeock
2016-09-01
The purpose of this study was to explore the criterion-related concurrent validity of two standardized auditory-perceptual rating protocols and the Acoustic Voice Quality Index (AVQI) for measuring dysphonia severity in Korean speech. Sixty native Korean subjects with various voice disorders were asked to sustain the vowel [a:] and to read aloud the Korean text "Walk." A 3-second midvowel portion of the sustained vowel and two sentences (with 25 syllables) were edited, concatenated, and analyzed according to methods described elsewhere. From 56 participants, both continuous speech and sustained vowel recordings had sufficiently high signal-to-noise ratios (35.5 dB and 37 dB on average, respectively) and were therefore subjected to further dysphonia severity analysis with (1) "G" or Grade from the GRBAS protocol, (2) "OS" or Overall Severity from the Consensus Auditory-Perceptual Evaluation of Voice protocol, and (3) AVQI. First, high correlations were found between G and OS (rS = 0.955 for sustained vowels; rS = 0.965 for continuous speech). Second, the AVQI showed a strong correlation with G (rS = 0.911) as well as OS (rP = 0.924). These findings are in agreement with similar studies dealing with continuous speech in other languages. The present study highlights the criterion-related concurrent validity of these methods in Korean speech. Furthermore, it supports the cross-linguistic robustness of the AVQI as a valid and objective marker of overall dysphonia severity. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Hammoudeh, Jeff A; Imahiyerobo, Thomas A; Liang, Fan; Fahradyan, Artur; Urbinelli, Leo; Lau, Jennifer; Matar, Marla; Magee, William; Urata, Mark
2017-06-01
The optimal timing for cleft lip repair has yet to be established. Advances in neonatal anesthesia, along with a growing body of literature, suggesting benefits of earlier cleft lip and nasal repair, have set the stage for a reexamination of current practices. In this prospective study, cleft lip and nasal repair occurred on average at 34.8 days (13-69 days). Nasal correction was achieved primarily through molding the nasal cartilage without the placement of nasal sutures at the time of repair. A standardized anesthetic protocol aimed at limiting neurotoxicity was utilized in all cases. Anesthetic and postoperative complications were assessed. A 3-dimensional nasal analysis compared pre- and postoperative nasal symmetry for unilateral clefts. Surveys assessed familial response to repair. Thirty-two patients were included (27 unilateral and 5 bilateral clefts). In this study, the overall complication rate was 3.1%. Anthropometric measurements taken from 3-dimensional-image models showed statistically significant improvement in ratios of nostril height (preoperative mean, 0.59; postoperative mean, 0.80), nasal base width (preoperative mean, 1.96; postoperative mean, 1.12), columella length (preoperative mean, 0.62; postoperative mean, 0.89; and columella angle (preoperative mean, 30.73; postoperative mean, 9.1). Survey data indicated that families uniformly preferred earlier repair. We present evidence that early cleft lip and nasal repair can be performed safely and is effective at improving nasal symmetry without the placement of any nasal sutures. Utilization of this protocol has the potential to be a paradigm shift in the treatment of cleft lip and nasal deformity.
León, Ileana R.; Schwämmle, Veit; Jensen, Ole N.; Sprenger, Richard R.
2013-01-01
The majority of mass spectrometry-based protein quantification studies uses peptide-centric analytical methods and thus strongly relies on efficient and unbiased protein digestion protocols for sample preparation. We present a novel objective approach to assess protein digestion efficiency using a combination of qualitative and quantitative liquid chromatography-tandem MS methods and statistical data analysis. In contrast to previous studies we employed both standard qualitative as well as data-independent quantitative workflows to systematically assess trypsin digestion efficiency and bias using mitochondrial protein fractions. We evaluated nine trypsin-based digestion protocols, based on standard in-solution or on spin filter-aided digestion, including new optimized protocols. We investigated various reagents for protein solubilization and denaturation (dodecyl sulfate, deoxycholate, urea), several trypsin digestion conditions (buffer, RapiGest, deoxycholate, urea), and two methods for removal of detergents before analysis of peptides (acid precipitation or phase separation with ethyl acetate). Our data-independent quantitative liquid chromatography-tandem MS workflow quantified over 3700 distinct peptides with 96% completeness between all protocols and replicates, with an average 40% protein sequence coverage and an average of 11 peptides identified per protein. Systematic quantitative and statistical analysis of physicochemical parameters demonstrated that deoxycholate-assisted in-solution digestion combined with phase transfer allows for efficient, unbiased generation and recovery of peptides from all protein classes, including membrane proteins. This deoxycholate-assisted protocol was also optimal for spin filter-aided digestions as compared with existing methods. PMID:23792921
Aloisio, Michelangelo; Bortot, Barbara; Gandin, Ilaria; Severini, Giovanni Maria; Athanasakis, Emmanouil
2017-02-01
Chimerism status evaluation of post-allogeneic hematopoietic stem cell transplantation samples is essential to predict post-transplant relapse. The most commonly used technique capable of detecting small increments of chimerism is quantitative real-time PCR. Although this method is already used in several laboratories, previously described protocols often lack sensitivity and the amount of the DNA required for each chimerism analysis is too high. In the present study, we compared a novel semi-nested allele-specific real-time PCR (sNAS-qPCR) protocol with our in-house standard allele-specific real-time PCR (gAS-qPCR) protocol. We selected two genetic markers and analyzed technical parameters (slope, y-intercept, R2, and standard deviation) useful to determine the performances of the two protocols. The sNAS-qPCR protocol showed better sensitivity and precision. Moreover, the sNAS-qPCR protocol requires, as input, only 10 ng of DNA, which is at least 10-fold less than the gAS-qPCR protocols described in the literature. Finally, the proposed sNAS-qPCR protocol could prove very useful for performing chimerism analysis with a small amount of DNA, as in the case of blood cell subsets.
A secure distributed logistic regression protocol for the detection of rare adverse drug events
El Emam, Khaled; Samet, Saeed; Arbuckle, Luk; Tamblyn, Robyn; Earle, Craig; Kantarcioglu, Murat
2013-01-01
Background There is limited capacity to assess the comparative risks of medications after they enter the market. For rare adverse events, the pooling of data from multiple sources is necessary to have the power and sufficient population heterogeneity to detect differences in safety and effectiveness in genetic, ethnic and clinically defined subpopulations. However, combining datasets from different data custodians or jurisdictions to perform an analysis on the pooled data creates significant privacy concerns that would need to be addressed. Existing protocols for addressing these concerns can result in reduced analysis accuracy and can allow sensitive information to leak. Objective To develop a secure distributed multi-party computation protocol for logistic regression that provides strong privacy guarantees. Methods We developed a secure distributed logistic regression protocol using a single analysis center with multiple sites providing data. A theoretical security analysis demonstrates that the protocol is robust to plausible collusion attacks and does not allow the parties to gain new information from the data that are exchanged among them. The computational performance and accuracy of the protocol were evaluated on simulated datasets. Results The computational performance scales linearly as the dataset sizes increase. The addition of sites results in an exponential growth in computation time. However, for up to five sites, the time is still short and would not affect practical applications. The model parameters are the same as the results on pooled raw data analyzed in SAS, demonstrating high model accuracy. Conclusion The proposed protocol and prototype system would allow the development of logistic regression models in a secure manner without requiring the sharing of personal health information. This can alleviate one of the key barriers to the establishment of large-scale post-marketing surveillance programs. We extended the secure protocol to account for correlations among patients within sites through generalized estimating equations, and to accommodate other link functions by extending it to generalized linear models. PMID:22871397
A secure distributed logistic regression protocol for the detection of rare adverse drug events.
El Emam, Khaled; Samet, Saeed; Arbuckle, Luk; Tamblyn, Robyn; Earle, Craig; Kantarcioglu, Murat
2013-05-01
There is limited capacity to assess the comparative risks of medications after they enter the market. For rare adverse events, the pooling of data from multiple sources is necessary to have the power and sufficient population heterogeneity to detect differences in safety and effectiveness in genetic, ethnic and clinically defined subpopulations. However, combining datasets from different data custodians or jurisdictions to perform an analysis on the pooled data creates significant privacy concerns that would need to be addressed. Existing protocols for addressing these concerns can result in reduced analysis accuracy and can allow sensitive information to leak. To develop a secure distributed multi-party computation protocol for logistic regression that provides strong privacy guarantees. We developed a secure distributed logistic regression protocol using a single analysis center with multiple sites providing data. A theoretical security analysis demonstrates that the protocol is robust to plausible collusion attacks and does not allow the parties to gain new information from the data that are exchanged among them. The computational performance and accuracy of the protocol were evaluated on simulated datasets. The computational performance scales linearly as the dataset sizes increase. The addition of sites results in an exponential growth in computation time. However, for up to five sites, the time is still short and would not affect practical applications. The model parameters are the same as the results on pooled raw data analyzed in SAS, demonstrating high model accuracy. The proposed protocol and prototype system would allow the development of logistic regression models in a secure manner without requiring the sharing of personal health information. This can alleviate one of the key barriers to the establishment of large-scale post-marketing surveillance programs. We extended the secure protocol to account for correlations among patients within sites through generalized estimating equations, and to accommodate other link functions by extending it to generalized linear models.
Pérez-Portela, Rocío; Riesgo, Ana
2013-09-01
Transcriptomic information provides fundamental insights into biological processes. Extraction of quality RNA is a challenging step, and preservation and extraction protocols need to be adjusted in many cases. Our objectives were to optimize preservation protocols for isolation of high-quality RNA from diverse echinoderm tissues and to compare the utility of parameters as absorbance ratios and RIN values to assess RNA quality. Three different tissues (gonad, oesophagus and coelomocytes) were selected from the sea urchin Arbacia lixula. Solid tissues were flash-frozen and stored at -80 °C until processed. Four preservation treatments were applied to coelomocytes: flash freezing and storage at -80 °C, RNAlater and storage at -20 °C, preservation in TRIzol reagent and storage at -80 °C and direct extraction with TRIzol from fresh cells. Extractions of total RNA were performed with a modified TRIzol protocol for all tissues. Our results showed high values of RNA quantity and quality for all tissues, showing nonsignificant differences among them. However, while flash freezing was effective for solid tissues, it was inadequate for coelomocytes because of the low quality of the RNA extractions. Coelomocytes preserved in RNAlater displayed large variability in RNA integrity and insufficient RNA amount for further isolation of mRNA. TRIzol was the most efficient system for stabilizing RNA which resulted on high RNA quality and quantity. We did not detect correlation between absorbance ratios and RNA integrity. The best strategies for assessing RNA integrity was the visualization of 18S rRNA and 28S rRNA bands in agarose gels and estimation of RIN values with Agilent Bioanalyzer chips. © 2013 John Wiley & Sons Ltd.
Sodhi, Kanwalpreet; Singla, Manender Kumar; Shrivastava, Anupam
2015-02-01
Despite advances in cardiopulmonary resuscitation and widespread life-support trainings, the outcomes of resuscitation are variable. There is a definitive need for organizational inputs to strengthen the resuscitation process. Our hospital authorities introduced certain changes at the organizational level in our in-house resuscitation protocol. We aimed to study the impact of these changes on the outcomes of resuscitation. The hospital code blue committee decided to reformulate the resuscitation protocols and reframe the code blue team. Various initiatives were taken in the form of infrastructural changes, procurement of equipment, organising certified training programs, conduct of mock code and simulation drills etc. A prospective and retrospective observational study was made over 6 years: a pre-intervention period, which included all cardiac arrests from January 2007 to December 2009, before the implementation of the program, and a post-intervention period from January 2010 to December 2012, after the implementation of the program. The outcomes of interest were response time, immediate survival, day/night survival and survival to discharge ratio. 2,164 in-hospital cardiac arrests were included in the study, 1,042 during the pre-intervention period and 1,122 during the post-intervention period. The survival percentage increased from 26.7 to 40.8 % (p < 0.05), and the survival to discharge ratio increased from 23.4 to 66.6 % (p < 0.05). Both day- and night-time survival improved (p < 0.05) and response time improved from 4 to 1.5 min. A strong hospital-based resuscitation policy with well-defined protocols and infrastructure has potential synergistic effect and plays a big role in improving the outcomes of resuscitation.
COLORECTAL CANCER PREVENTION BY AN OPTIMIZED COLONOSCOPY PROTOCOL IN ROUTINE PRACTICE
Xirasagar, Sudha; Li, Yi-Jhen; Hurley, Thomas G.; Tsai, Meng Han; Hardin, James W.; Hurley, Deborah M.; Hebert, James R.; de Groen, Piet C.
2014-01-01
We conducted a retrospective cohort study to investigate the colorectal cancer (CRC) incidence and mortality prevention achievable in clinical practice with an optimized colonoscopy protocol targeting near-complete polyp clearance. The protocol consisted of: a) telephonic reinforcement of bowel preparation instructions; b) active inspection for polyps throughout insertion and circumferential withdrawal; and, c) timely updating of the protocol and documentation to incorporate the latest guidelines. Of 17,312 patients provided screening colonoscopies by 59 endoscopists in South Carolina, USA from 09/2001 through 12/2008, 997 were excluded using accepted exclusion criteria. Data on 16,315 patients were merged with the South Carolina Central Cancer Registry and Vital Records Registry data from 01/1996 – 12/2009 to identify incident CRC cases and deaths, incident lung cancers and brain cancer deaths (comparison control cancers). The standardized incidence ratios (SIR) and standardized mortality ratios (SMR) relative to South Carolina and US SEER-18 population rates were calculated. Over 78,375 person-years of observation, 18 patients developed CRC vs. 104.11 expected for an SIR of 0.17, or 83% CRC protection, the rates being 68% and 91%, respectively among the adenoma- and adenoma-free subgroups (all p<0.001). Restricting the cohort to ensure minimum 5-year follow-up (mean follow-up 6.58 years) did not change the results. The CRC mortality reduction was 89% (p<0.001; 4 CRC deaths vs. 35.95 expected). The lung cancer SIR was 0.96 (p=0.67), and brain cancer SMR was 0.92 (p=0.35). Over 80% reduction in CRC incidence and mortality is achievable in routine practice by implementing key colonoscopy principles targeting near-complete polyp clearance. PMID:25242510
Ultimate Data Hiding in Quantum Mechanics and Beyond
NASA Astrophysics Data System (ADS)
Lami, Ludovico; Palazuelos, Carlos; Winter, Andreas
2018-06-01
The phenomenon of data hiding, i.e. the existence of pairs of states of a bipartite system that are perfectly distinguishable via general entangled measurements yet almost indistinguishable under LOCC, is a distinctive signature of nonclassicality. The relevant figure of merit is the maximal ratio (called data hiding ratio) between the distinguishability norms associated with the two sets of measurements we are comparing, typically all measurements vs LOCC protocols. For a bipartite {n× n} quantum system, it is known that the data hiding ratio scales as n, i.e. the square root of the real dimension of the local state space of density matrices. We show that for bipartite {n_A× n_B} systems the maximum data hiding ratio against LOCC protocols is Θ(\\min{n_A,n_B}) . This scaling is better than the previously obtained upper bounds O(√{n_A n_B}) and \\min{n_A^2, n_B^2} , and moreover our intuitive argument yields constants close to optimal. In this paper, we investigate data hiding in the more general context of general probabilistic theories (GPTs), an axiomatic framework for physical theories encompassing only the most basic requirements about the predictive power of the theory. The main result of the paper is the determination of the maximal data hiding ratio obtainable in an arbitrary GPT, which is shown to scale linearly in the minimum of the local dimensions. We exhibit an explicit model achieving this bound up to additive constants, finding that quantum mechanical data hiding ratio is only of the order of the square root of the maximal one. Our proof rests crucially on an unexpected link between data hiding and the theory of projective and injective tensor products of Banach spaces. Finally, we develop a body of techniques to compute data hiding ratios for a variety of restricted classes of GPTs that support further symmetries.
21 CFR 312.83 - Treatment protocols.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Treatment protocols. 312.83 Section 312.83 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR...-debilitating Illnesses § 312.83 Treatment protocols. If the preliminary analysis of phase 2 test results...
21 CFR 312.83 - Treatment protocols.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Treatment protocols. 312.83 Section 312.83 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR...-debilitating Illnesses § 312.83 Treatment protocols. If the preliminary analysis of phase 2 test results...
21 CFR 312.83 - Treatment protocols.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Treatment protocols. 312.83 Section 312.83 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR...-debilitating Illnesses § 312.83 Treatment protocols. If the preliminary analysis of phase 2 test results...
40 CFR 766.28 - Expert review of protocols.
Code of Federal Regulations, 2013 CFR
2013-07-01
... CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS Specific Chemical Testing/Reporting Requirements § 766.28 Expert review of protocols. EPA will gather a panel of experts in analysis of chemical matrices for HDDs... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Expert review of protocols. 766.28...
40 CFR 766.28 - Expert review of protocols.
Code of Federal Regulations, 2014 CFR
2014-07-01
... CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS Specific Chemical Testing/Reporting Requirements § 766.28 Expert review of protocols. EPA will gather a panel of experts in analysis of chemical matrices for HDDs... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Expert review of protocols. 766.28...
40 CFR 766.28 - Expert review of protocols.
Code of Federal Regulations, 2011 CFR
2011-07-01
... CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS Specific Chemical Testing/Reporting Requirements § 766.28 Expert review of protocols. EPA will gather a panel of experts in analysis of chemical matrices for HDDs... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Expert review of protocols. 766.28...
40 CFR 766.28 - Expert review of protocols.
Code of Federal Regulations, 2012 CFR
2012-07-01
... CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS Specific Chemical Testing/Reporting Requirements § 766.28 Expert review of protocols. EPA will gather a panel of experts in analysis of chemical matrices for HDDs... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Expert review of protocols. 766.28...
75 FR 53273 - Federal Aquatic Nuisance Species Research Risk Analysis Protocol
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
....)]. The Protocol encourages the incorporation of a Hazard Analysis and Critical Control Point (HACCP) approach for prevention planning within research activities. Information about the use of HACCP is available at http://www.seagrant.umn.edu/ais/haccp . A web site detailing the application of HACCP to...
ter Wee, Marieke M; Coupé, Veerle MH; den Uyl, Debby; Blomjous, Birgit S; Kooijmans, Esmee; Kerstens, Pit JSM; Nurmohamed, Mike T; van Schaardenburg, Dirkjan; Voskuyl, Alexandre E; Boers, Maarten; Lems, Willem F
2017-01-01
Objective To evaluate if COmbinatie therapie Bij Reumatoïde Artritis (COBRA)-light therapy is cost-effective in treating patients with early rheumatoid arthritis (RA) compared with COBRA therapy. Methods This economic evaluation was performed next to the open-label, randomised non-inferiority COBRA-light trial in 164 patients with early RA. Non-responders to COBRA or COBRA-light received etanercept (50 mg/week) for 3–6 months. The societal perspective analysis took medical direct, non-medical direct and indirect costs into account. Costs were measured with patient cost diaries for the follow-up period of 52 weeks. Bootstrapping techniques estimated uncertainty around the cost-effectiveness ratios, presented in cost-effectiveness planes. Results 164 patients were randomised to either COBRA or COBRA-light strategy. At week 52, COBRA-light proved to be non-inferior to COBRA therapy on all clinical outcome measures. The results of the base-case cost-utility analysis (intention-to-treat analyses) revealed that COBRA-light strategy is more expensive (k€9.3 (SD 0.9) compared with COBRA (k€7.2 (SD 0.8)), but the difference in costs were not significant (k€2.0; 95% CI –0.3 to 4.4). Also, both strategies produced similar quality-adjusted life-years (QALYs). The sensitivity analyses showed robustness of these results. In a per-protocol sensitivity analysis, in which costs of etanercept were assumed to be provided as prescribed according to protocol, both arms had much higher costs: COBRA-light: k€11.5 (8.3) compared with k€8.5 (6.8) for COBRA, and the difference in costs was significant (k€2.9; 0.6 to 5.3). Conclusions In the base-case cost-utility analysis, the two strategies produced similar QALYs for similar costs. But it is anticipated that if protocol had been followed correctly, the COBRA-light strategy would have been more costly due to additional etanercept costs, for a limited health gain. Given the limited added benefit and high costs of starting etanercept in the presence of low disease activity in our trial, such a strategy needs better justification than is available now. Trial registration number 55552928, Results. PMID:29119006
NASA Technical Reports Server (NTRS)
James, Jeffrey M.; Sanderson, Penelope M.; Seidler, Karen S.
1990-01-01
As modern transport environments become increasingly complex, issues such as crew communication, interaction with automation, and workload management have become crucial. Much research is being focused on holistic aspects of social and cognitive behavior, such as the strategies used to handle workload, the flow of information, the scheduling of tasks, the verbal and non-verbal interactions between crew members. Traditional laboratory performance measures no longer sufficiently meet the needs of researchers addressing these issues. However observational techniques are better equipped to capture the type of data needed and to build models of the requisite level of sophistication. Presented here is SHAPA, an interactive software tool for performing both verbal and non-verbal protocol analysis. It has been developed with the idea of affording the researchers the closest possible degree of engagement with protocol data. The researcher can configure SHAPA to encode protocols using any theoretical framework or encoding vocabulary that is desired. SHAPA allows protocol analysis to be performed at any level of analysis, and it supplies a wide variety of tools for data aggregation, manipulation. The output generated by SHAPA can be used alone or in combination with other performance variables to get a rich picture of the influences on sequences of verbal or nonverbal behavior.
Cloostermans, Laura; Wendel-Vos, Wanda; Doornbos, Gerda; Howard, Bethany; Craig, Cora Lynn; Kivimäki, Mika; Tabak, Adam G; Jefferis, Barbara J; Ronkainen, Kimmo; Brown, Wendy J; Picavet, Susan H S J; Ben-Shlomo, Yoav; Laukkanen, Jari Antero; Kauhanen, Jussi; Bemelmans, Wanda J E
2015-12-01
The aim of this harmonized meta-analysis was to examine the independent and combined effects of physical activity and BMI on the incidence of type 2 diabetes. Our systematic literature review in 2011 identified 127 potentially relevant prospective studies of which 9 fulfilled the inclusion criteria (total N = 117,878, 56.2 % female, mean age = 50.0 years, range = 25-65 years). Measures of baseline physical activity (low, intermediate, high), BMI-category [BMI < 18.4 (underweight), 18.5-24.9 (normal weight), 25.0-29.9 (overweight), 30+ (obese)] and incident type 2 diabetes were harmonized across studies. The associations between physical activity, BMI and incident type 2 diabetes were analyzed using Cox regression with a standardized analysis protocol including adjustments for age, gender, educational level, and smoking. Hazard ratios from individual studies were combined in a random-effects meta-analysis. Mean follow-up time was 9.1 years. A total of 11,237 incident type 2 diabetes cases were recorded. In mutually adjusted models, being overweight or obese (compared with normal weight) and having low physical activity (compared with high physical activity) were associated with an increased risk of incident type 2 diabetes (hazard ratios 2.33, 95 % CI 1.95-2.78; 6.10, 95 % CI: 4.63-8.04, and 1.23, 95 % CI: 1.09-1.39, respectively). Individuals who were both obese and had low physical activity had 7.4-fold (95 % CI 3.47-15.89) increased risk of type 2 diabetes compared with normal weight, high physically active participants. This harmonized meta-analysis shows the importance of maintaining a healthy weight and being physically active in diabetes prevention.
de Oliveira, Marcus Vinicius Linhares; Santos, António Carvalho; Paulo, Graciano; Campos, Paulo Sergio Flores; Santos, Joana
2017-06-01
The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.
Sacarlal, Jahit; Muchanga, Vasco; Mabutana, Carlos; Mabui, Matilde; Mariamo, Arlete; Cuamba, Assa Júlio; Fumo, Leida Artur; Silveira, Jacinta; Heitman, Elizabeth; Moon, Troy D
2018-05-23
Mozambique has seen remarkable growth in biomedical research over the last decade. To meet a growing need, the National Committee for Bioethics in Health of Mozambique (CNBS) encouraged the development of ethical review processes at institutions that regularly conduct medical and social science research. In 2012, the Faculty of Medicine (FM) of University Eduardo Mondlane (UEM) and the Maputo Central Hospital (MCH) established a joint Institutional Committee on Bioethics for Health (CIBS FM & MCH). This study examines the experience of the first 4 years of the CIBS FM & MCH. This study provides a descriptive, retrospective analysis of research protocols submitted to and approved by the CIBS FM & MCH between March 1, 2013 and December 31, 2016, together with an analysis of the Committee's respective reviews and actions. A total of 356 protocols were submitted for review during the period under analysis, with 309 protocols approved. Sixty-four percent were submitted by students, faculty, and researchers from UEM, mainly related to Master's degree research (42%). Descriptive cross-sectional studies were the most frequently reviewed research (61%). The majority were prospective (71%) and used quantitative methodologies (51%). The Departments of Internal Medicine at MCH and Community Health at the FM submitted the most protocols from their respective institutions, with 38 and 53% respectively. The CIBS's average time to final approval for all protocols was 56 days, rising to 161 for the 40 protocols that required subsequent national-level review by the CNBS. Our results show that over its first 4 years, the CIBS FM & MCH has been successful in managing a constant demand for protocol review and that several broad quality improvement initiatives, such as investigator mentoring and an electronic protocol submission platform have improved efficiency in the review process and the overall quality of the protocols submitted. Beyond Maputo, long-term investments in training and ethical capacity building for CIBS across the country continue to be needed, as Mozambique develops greater capacity for research and makes progress toward improving the health of all its citizens.
Modelling the protocol stack in NCS with deterministic and stochastic petri net
NASA Astrophysics Data System (ADS)
Hui, Chen; Chunjie, Zhou; Weifeng, Zhu
2011-06-01
Protocol stack is the basis of the networked control systems (NCS). Full or partial reconfiguration of protocol stack offers both optimised communication service and system performance. Nowadays, field testing is unrealistic to determine the performance of reconfigurable protocol stack; and the Petri net formal description technique offers the best combination of intuitive representation, tool support and analytical capabilities. Traditionally, separation between the different layers of the OSI model has been a common practice. Nevertheless, such a layered modelling analysis framework of protocol stack leads to the lack of global optimisation for protocol reconfiguration. In this article, we proposed a general modelling analysis framework for NCS based on the cross-layer concept, which is to establish an efficiency system scheduling model through abstracting the time constraint, the task interrelation, the processor and the bus sub-models from upper and lower layers (application, data link and physical layer). Cross-layer design can help to overcome the inadequacy of global optimisation based on information sharing between protocol layers. To illustrate the framework, we take controller area network (CAN) as a case study. The simulation results of deterministic and stochastic Petri-net (DSPN) model can help us adjust the message scheduling scheme and obtain better system performance.
Hamuro, Yoshitomo
2017-03-01
A new strategy to analyze amide hydrogen/deuterium exchange mass spectrometry (HDX-MS) data is proposed, utilizing a wider time window and isotope envelope analysis of each peptide. While most current scientific reports present HDX-MS data as a set of time-dependent deuteration levels of peptides, the ideal HDX-MS data presentation is a complete set of backbone amide hydrogen exchange rates. The ideal data set can provide single amide resolution, coverage of all exchange events, and the open/close ratio of each amide hydrogen in EX2 mechanism. Toward this goal, a typical HDX-MS protocol was modified in two aspects: measurement of a wider time window in HDX-MS experiments and deconvolution of isotope envelope of each peptide. Measurement of a wider time window enabled the observation of deuterium incorporation of most backbone amide hydrogens. Analysis of the isotope envelope instead of centroid value provides the deuterium distribution instead of the sum of deuteration levels in each peptide. A one-step, global-fitting algorithm optimized exchange rate and deuterium retention during the analysis of each amide hydrogen by fitting the deuterated isotope envelopes at all time points of all peptides in a region. Application of this strategy to cytochrome c yielded 97 out of 100 amide hydrogen exchange rates. A set of exchange rates determined by this approach is more appropriate for a patent or regulatory filing of a biopharmaceutical than a set of peptide deuteration levels obtained by a typical protocol. A wider time window of this method also eliminates false negatives in protein-ligand binding site identification. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Hamuro, Yoshitomo
2017-03-01
A new strategy to analyze amide hydrogen/deuterium exchange mass spectrometry (HDX-MS) data is proposed, utilizing a wider time window and isotope envelope analysis of each peptide. While most current scientific reports present HDX-MS data as a set of time-dependent deuteration levels of peptides, the ideal HDX-MS data presentation is a complete set of backbone amide hydrogen exchange rates. The ideal data set can provide single amide resolution, coverage of all exchange events, and the open/close ratio of each amide hydrogen in EX2 mechanism. Toward this goal, a typical HDX-MS protocol was modified in two aspects: measurement of a wider time window in HDX-MS experiments and deconvolution of isotope envelope of each peptide. Measurement of a wider time window enabled the observation of deuterium incorporation of most backbone amide hydrogens. Analysis of the isotope envelope instead of centroid value provides the deuterium distribution instead of the sum of deuteration levels in each peptide. A one-step, global-fitting algorithm optimized exchange rate and deuterium retention during the analysis of each amide hydrogen by fitting the deuterated isotope envelopes at all time points of all peptides in a region. Application of this strategy to cytochrome c yielded 97 out of 100 amide hydrogen exchange rates. A set of exchange rates determined by this approach is more appropriate for a patent or regulatory filing of a biopharmaceutical than a set of peptide deuteration levels obtained by a typical protocol. A wider time window of this method also eliminates false negatives in protein-ligand binding site identification.
Kloß, Sandra; Lorenz, Björn; Dees, Stefan; Labugger, Ines; Rösch, Petra; Popp, Jürgen
2015-11-01
Lower respiratory tract infections are the fourth leading cause of death worldwide. Here, a timely identification of the causing pathogens is crucial to the success of the treatment. Raman spectroscopy allows for quick identification of bacterial cells without the need for time-consuming cultivation steps, which is the current gold standard to detect pathogens. However, before Raman spectroscopy can be used to identify pathogens, they have to be isolated from the sample matrix, i.e., sputum in case of lower respiratory tract infections. In this study, we report an isolation protocol for single bacterial cells from sputum samples for Raman spectroscopic identification. Prior to the isolation, a liquefaction step using the proteolytic enzyme mixture Pronase E is required in order to deal with the high viscosity of sputum. The extraction of the bacteria was subsequently performed via different filtration and centrifugation steps, whereby isolation ratios between 46 and 57 % were achieved for sputa spiked with 6·10(7) to 6·10(4) CFU/mL of Staphylococcus aureus. The compatibility of such a liquefaction and isolation procedure towards a Raman spectroscopic classification was shown for five different model species, namely S. aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Klebsiella pneumoniae, and Pseudomonas aeruginosa. A classification of single-cell Raman spectra of these five species with an accuracy of 98.5 % could be achieved on the basis of a principal component analysis (PCA) followed by a linear discriminant analysis (LDA). These classification results could be validated with an independent test dataset, where 97.4 % of all spectra were identified correctly. Graphical Abstract Development of an isolation protocol of bacterial cells out of sputum samples followed by Raman spectroscopic measurement and species identification using chemometrical models.
La Monica, Michael B; Fukuda, David H; Beyer, Kyle S; Hoffman, Mattan W; Miramonti, Amelia A; Riffe, Josh J; Baker, Kayla M; Fragala, Maren S; Hoffman, Jay R; Stout, Jeffrey R
2016-02-01
This study examined the influence of recovery time on fatigue indices, performance (total work [TW], peak power [PP], and mean power [MP]), and oxygen consumption during repeated sprint ability (RSA) on a cycle ergometer. Eight recreationally-trained men performed 3 RSA protocols consisting of 10 × 6 s sprints with 12 s, 18 s, and 24 s rest intervals between each sprint. Fatigue indices were determined as percent decrement (%Dec) and rate of decline using either a log transform method or standard slope approach for TW, PP, and MP during respective RSA protocols. The maximal VO2 value in response to given sprint intervals and the minimal VO2 value in response to given rest periods (VO2 work and VO2 rest, respectively) were recorded. A repeated measures analysis of variance was used to analyze all variables. Average VO2 work was not different among rest interval trials. Average VO2 rest with 12 s rest was greater than 18 s and 24 s (2.16 ± 0.17 L · min(-1), 1.91 ± 0.18 L · min(-1), 1.72 ± 0.15 L · min(-1), respectively), while 18 s was greater than 24 s. Average TW and MP were greater with 24 s rest than 12 s (4,604.44 ± 915.98 J vs. 4,305.46 ± 727.17 J, respectively), with no differences between RSA protocols for PP. No differences in %Dec were observed. Both methods of calculating rates of decline per sprint for PP and TW were greater during 12 s than 18 s or 24 s. Since changes were only noted between the 12 s and 24 s protocols, a 6 s differential in rest intervals may not be enough to elicit alterations in TW, PP, MP, or %Dec in RSA performance. Rate of decline may be a more sensitive measure of fatigue than %Dec.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katsuta, Y; Kadoya, N; Shimizu, E
2015-06-15
Purpose: A successful VMAT plan delivery includes precise modulations of dose rate, gantry rotational and multi-leaf collimator shapes. The purpose of this research is to construct routine QA protocol which focuses on VMAT delivery technique and to obtain a baseline including dose error, fluence distribution and mechanical accuracy during VMAT. Methods: The mock prostate, head and neck (HN) cases supplied from AAPM were used in this study. A VMAT plans were generated in Monaco TPS according to TG-119 protocol. Plans were created using 6 MV and 10 MV photon beams for each case. The phantom based measurement, fluence measurement andmore » log files analysis were performed. The dose measurement was performed using 0.6 cc ion chamber, which located at isocenter. The fluence distribution were acquired using the MapCHECK2 mounted in the MapPHAN. The trajectory log files recorded inner 20 leaf pairs and gantry angle positions at every 0.25 sec interval were exported to in-house software developed by MATLAB and determined those RMS values. Results: The dose difference is expressed as a ratio of the difference between measured and planned doses. The dose difference for 6 MV was 0.91%, for 10 MV was 0.67%. In turn, the fluence distribution using gamma criteria of 2%/2 mm with a 50% minimum dose threshold for 6 MV was 98.8%, for 10 MV was 97.5%, respectively. The RMS values of MLC for 6 MV and 10 MV were 0.32 mm and 0.37 mm, of gantry were 0.33 degree and 0.31 degree. Conclusion: In this study, QA protocol to assess VMAT delivery accuracy is constructed and results acquired in this study are used as a baseline of VMAT delivery performance verification.« less
Vandenberg, Curt; Niswander, Cameron; Carry, Patrick; Bloch, Nikki; Pan, Zhaoxing; Erickson, Mark; Garg, Sumeet
A multidisciplinary task force, designated Target Zero, has developed protocols for prevention of surgical site infection (SSI) for spine surgery at our institution. The purpose of this study was to evaluate how compliance with an antibiotic bundle impacts infection incidences in pediatric spine surgery. After institutional review board approval, a consecutive series of 511 patients (517 procedures) who underwent primary spine procedures from 2008 to 2012 were retrospectively reviewed to identify patients who developed SSI. Patients were followed for a minimum of 90 days postoperatively. Compliance data were collected prospectively in 511 consecutive patients and a total of 517 procedures. Three criteria were required for antibiotic bundle compliance: appropriate antibiotics completely administered within 1 hour before incision, antibiotics appropriately redosed intraoperatively for blood loss and time, and antibiotics discontinued within 24 hours postoperatively. A multivariable logistic regression analysis was used to test the association between compliance and the development of an infection. Overall antibiotic bundle compliance rate was 85%. After adjusting for risk category, estimated blood loss, and study year, the likelihood of an infection was increased in the noncompliant group compared with the compliant group (adjusted odds ratio: 3.0, 95% CI, 0.96-9.47, P=0.0587). When expressed as the number needed to treat, strict adherence to antibiotic bundle compliance prevented 1 SSI within 90 days of surgery for every 26 patients treated with the antibiotic bundle. Reasons for noncompliance included failure to infuse preoperative antibiotics 1 hour before incision (10.3%), failure to redose antibiotics intraoperatively based on time or blood loss (5.5%), and failure to discontinue antibiotics within 24 hours postoperatively (1.9%). Compliance with a comprehensive antibiotic protocol can lead to meaningful reductions in SSI incidences in pediatric spine surgery. Institutions should focus on improving compliance with prophylactic antibiotic protocols to decrease SSI in pediatric spine surgery. Level III-retrospective cohort study.
Geyer, L L; Körner, M; Hempel, R; Deak, Z; Mueck, F G; Linsenmaier, U; Reiser, M F; Wirth, S
2013-07-01
To evaluate radiation exposure for 64-row computed tomography (CT) of the cervical spine comparing two optimized protocols using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR), respectively. Sixty-seven studies using FBP (scanner 1) were retrospectively compared with 80 studies using ASIR (scanner 2). The key scanning parameters were identical (120 kV dose modulation, 64 × 0.625 mm collimation, pitch 0.531:1). In protocol 2, the noise index (NI) was increased from 5 to 25, and ASIR and the high-definition (HD) mode were used. The scan length, CT dose index (CTDI), and dose-length product (DLP) were recorded. The image quality was analysed subjectively by using a three-point scale (0; 1; 2), and objectively by using a region of interest (ROI) analysis. Mann-Whitney U and Wilcoxon's test were used. In the FBP group, the mean CTDI was 21.43 mGy, mean scan length 186.3 mm, and mean DLP 441.15 mGy cm. In the ASIR group, the mean CTDI was 9.57 mGy, mean scan length 195.21 mm, and mean DLP 204.23 mGy cm. The differences were significant for CTDI and DLP (p < 0.001) and scan length (p = 0.01). There was no significant difference in the subjective image quality (p > 0.05). The estimated mean effective dose decreased from 2.38 mSv (FBP) to 1.10 mSv (ASIR). The radiation dose of 64-row MDCT can be reduced to a level comparable to plain radiography without loss of subjective image quality by implementation of ASIR in a dedicated cervical spine trauma protocol. These results might contribute to an improved relative risk-to-benefit ratio and support the justification of CT as a first-line imaging tool to evaluate cervical spine trauma. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Counterfactual Quantum Deterministic Key Distribution
NASA Astrophysics Data System (ADS)
Zhang, Sheng; Wang, Jian; Tang, Chao-Jing
2013-01-01
We propose a new counterfactual quantum cryptography protocol concerning about distributing a deterministic key. By adding a controlled blocking operation module to the original protocol [T.G. Noh, Phys. Rev. Lett. 103 (2009) 230501], the correlation between the polarizations of the two parties, Alice and Bob, is extended, therefore, one can distribute both deterministic keys and random ones using our protocol. We have also given a simple proof of the security of our protocol using the technique we ever applied to the original protocol. Most importantly, our analysis produces a bound tighter than the existing ones.
One Step Quantum Key Distribution Based on EPR Entanglement.
Li, Jian; Li, Na; Li, Lei-Lei; Wang, Tao
2016-06-30
A novel quantum key distribution protocol is presented, based on entanglement and dense coding and allowing asymptotically secure key distribution. Considering the storage time limit of quantum bits, a grouping quantum key distribution protocol is proposed, which overcomes the vulnerability of first protocol and improves the maneuverability. Moreover, a security analysis is given and a simple type of eavesdropper's attack would introduce at least an error rate of 46.875%. Compared with the "Ping-pong" protocol involving two steps, the proposed protocol does not need to store the qubit and only involves one step.
Shih, Weichung Joe; Li, Gang; Wang, Yining
2016-03-01
Sample size plays a crucial role in clinical trials. Flexible sample-size designs, as part of the more general category of adaptive designs that utilize interim data, have been a popular topic in recent years. In this paper, we give a comparative review of four related methods for such a design. The likelihood method uses the likelihood ratio test with an adjusted critical value. The weighted method adjusts the test statistic with given weights rather than the critical value. The dual test method requires both the likelihood ratio statistic and the weighted statistic to be greater than the unadjusted critical value. The promising zone approach uses the likelihood ratio statistic with the unadjusted value and other constraints. All four methods preserve the type-I error rate. In this paper we explore their properties and compare their relationships and merits. We show that the sample size rules for the dual test are in conflict with the rules of the promising zone approach. We delineate what is necessary to specify in the study protocol to ensure the validity of the statistical procedure and what can be kept implicit in the protocol so that more flexibility can be attained for confirmatory phase III trials in meeting regulatory requirements. We also prove that under mild conditions, the likelihood ratio test still preserves the type-I error rate when the actual sample size is larger than the re-calculated one. Copyright © 2015 Elsevier Inc. All rights reserved.
Threshold Things That Think: Authorisation for Resharing
NASA Astrophysics Data System (ADS)
Peeters, Roel; Kohlweiss, Markulf; Preneel, Bart
As we are evolving towards ubiquitous computing, users carry an increasing number of mobile devices with sensitive information. The security of this information can be protected using threshold cryptography, in which secret computations are shared between multiple devices. Threshold cryptography can be made more robust by resharing protocols, which allow recovery from partial compromises. This paper introduces user-friendly and secure protocols for the authorisation of resharing protocols. We present both automatic and manual protocols, utilising a group manual authentication protocol to add a new device. We analyse the security of these protocols: our analysis considers permanent and temporary compromises, denial of service attacks and manual authentications errors of the user.
NASA Astrophysics Data System (ADS)
Everaers, Ralf
2012-08-01
We show that the front factor appearing in the shear modulus of a phantom network, Gph=(1-2/f)(ρkBT)/Ns, also controls the ratio of the strand length, Ns, and the number of monomers per Kuhn length of the primitive paths, NphPPKuhn, characterizing the average network conformation. In particular, NphPPKuhn=Ns/(1-2/f) and Gph=(ρkBT)/NphPPKuhn. Neglecting the difference between cross-links and slip-links, these results can be transferred to entangled systems and the interpretation of primitive path analysis data. In agreement with the tube model, the analogy to phantom networks suggest that the rheological entanglement length, Nerheo=(ρkBT)/Ge, should equal NePPKuhn. Assuming binary entanglements with f=4 functional junctions, we expect that Nerheo should be twice as large as the topological entanglement length, Netopo. These results are in good agreement with reported primitive path analysis results for model systems and a wide range of polymeric materials. Implications for tube and slip-link models are discussed.
A Hybrid Analysis for Security Protocols with State
2014-07-16
Approved for Public Release; Distribution Unlimited. 14-1013. A Hybrid Analysis for Security Protocols with State∗ John D. Ramsdell Daniel J ...their consequences in the anno - tated protocol theory Tannot(Π, ) use only the limited vocabulary of Tbnd(Π); we call them bridge lemmas. Lemma 3 is a...and we proved it using pvs. Lemma 1 (Prefix Boot Extend). ∀π ∈ path, t :>, i, k ∈ N. i ≤ k ∧ π(k) has t ⊃ subterm(π(i), π(k)) ∨ ∃ j ∈ N. i ≤ j < k ∧ π
Castle, John; Garrett-Engele, Phil; Armour, Christopher D; Duenwald, Sven J; Loerch, Patrick M; Meyer, Michael R; Schadt, Eric E; Stoughton, Roland; Parrish, Mark L; Shoemaker, Daniel D; Johnson, Jason M
2003-01-01
Microarrays offer a high-resolution means for monitoring pre-mRNA splicing on a genomic scale. We have developed a novel, unbiased amplification protocol that permits labeling of entire transcripts. Also, hybridization conditions, probe characteristics, and analysis algorithms were optimized for detection of exons, exon-intron edges, and exon junctions. These optimized protocols can be used to detect small variations and isoform mixtures, map the tissue specificity of known human alternative isoforms, and provide a robust, scalable platform for high-throughput discovery of alternative splicing.
Castle, John; Garrett-Engele, Phil; Armour, Christopher D; Duenwald, Sven J; Loerch, Patrick M; Meyer, Michael R; Schadt, Eric E; Stoughton, Roland; Parrish, Mark L; Shoemaker, Daniel D; Johnson, Jason M
2003-01-01
Microarrays offer a high-resolution means for monitoring pre-mRNA splicing on a genomic scale. We have developed a novel, unbiased amplification protocol that permits labeling of entire transcripts. Also, hybridization conditions, probe characteristics, and analysis algorithms were optimized for detection of exons, exon-intron edges, and exon junctions. These optimized protocols can be used to detect small variations and isoform mixtures, map the tissue specificity of known human alternative isoforms, and provide a robust, scalable platform for high-throughput discovery of alternative splicing. PMID:14519201
Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel
2017-01-01
ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile. PMID:29340488
Medini, Salim; Janin, Myriam; Verdoux, Patrick; Techer, Isabelle
2015-03-15
The lack of a geographical identification protocol for olive oils can lead to fraud and health risks. As some works call for Sr isotopes for the geographical identification of agri-food products, this study focus on the feasibility of extracting Sr from olive oils for isotopic measurements by TIMS. In fact, existing protocols for purification of Sr are unsuitable for lipid matrix. The defined protocol is applied to samples of PDO Nîmes olive oil. The accuracy of the extraction procedure is tested against isotopic standards. The values obtained are in conformity with NIST certified values. This consistency demonstrates that no modification of (87)Sr/(86)Sr ratio is brought about by this protocol. Consequently, the method is preliminary used on PDO Nîmes and Moroccan oils to evaluate the feasibility of a discriminant Sr signature on the two geographical products. This study provides promising results for the geographical discrimination and identification of PDO olive oils. Copyright © 2014 Elsevier Ltd. All rights reserved.
Suraniti, Emmanuel; Studer, Vincent; Sojic, Neso; Mano, Nicolas
2011-04-01
Immobilization and electrical wiring of enzymes is of particular importance for the elaboration of efficient biosensors and can be cumbersome. Here, we report a fast and easy protocol for enzyme immobilization, and as a proof of concept, we applied it to the immobilization of bilirubin oxidase, a labile enzyme. In the first step, bilirubin oxidase is mixed with a redox hydrogel "wiring" the enzyme reaction centers to electrodes. Then, this adduct is covered by an outer layer of PEGDA made by photoinitiated polymerization of poly(ethylene-glycol) diacrylate (PEGDA) and a photoclivable precursor, DAROCUR. This two-step protocol is 18 times faster than the current state-of-the-art protocol and leads to currents 25% higher. In addition, the outer layer of PEGDA acts as a protective layer increasing the lifetime of the electrode by 100% when operating continuously for 2000 s and by 60% when kept in dry state for 24 h. This new protocol is particularly appropriate for labile enzymes that quickly denaturate. In addition, by tuning the ratio PEGDA/DAROCUR, it is possible to make the enzyme electrodes even more active or more stable.
Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel
2017-01-01
To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.
A secure RFID authentication protocol adopting error correction code.
Chen, Chien-Ming; Chen, Shuai-Min; Zheng, Xinying; Chen, Pei-Yu; Sun, Hung-Min
2014-01-01
RFID technology has become popular in many applications; however, most of the RFID products lack security related functionality due to the hardware limitation of the low-cost RFID tags. In this paper, we propose a lightweight mutual authentication protocol adopting error correction code for RFID. Besides, we also propose an advanced version of our protocol to provide key updating. Based on the secrecy of shared keys, the reader and the tag can establish a mutual authenticity relationship. Further analysis of the protocol showed that it also satisfies integrity, forward secrecy, anonymity, and untraceability. Compared with other lightweight protocols, the proposed protocol provides stronger resistance to tracing attacks, compromising attacks and replay attacks. We also compare our protocol with previous works in terms of performance.
A Secure RFID Authentication Protocol Adopting Error Correction Code
Zheng, Xinying; Chen, Pei-Yu
2014-01-01
RFID technology has become popular in many applications; however, most of the RFID products lack security related functionality due to the hardware limitation of the low-cost RFID tags. In this paper, we propose a lightweight mutual authentication protocol adopting error correction code for RFID. Besides, we also propose an advanced version of our protocol to provide key updating. Based on the secrecy of shared keys, the reader and the tag can establish a mutual authenticity relationship. Further analysis of the protocol showed that it also satisfies integrity, forward secrecy, anonymity, and untraceability. Compared with other lightweight protocols, the proposed protocol provides stronger resistance to tracing attacks, compromising attacks and replay attacks. We also compare our protocol with previous works in terms of performance. PMID:24959619
Peres, Marco A.; Peres, Karen G.; Cascaes, Andreia M.; Correa, Marcos B.; Demarco, Flávio F.; Hallal, Pedro C.; Horta, Bernardo L.; Gigante, Denise P.; Menezes, Ana B.
2012-01-01
Background Most studies comparing prevalence of periodontal disease and risk factors by using partial protocols were performed in adult populations, with several studies being conducted in clinical settings. The aim of this study is to assess the accuracy of partial protocols in estimating the prevalence of periodontal outcomes in adolescents and young adults from two population-based birth cohorts from Pelotas, Brazil, and to assess differences in the estimation and strength of the effect measures when partial protocols are adopted compared to full-mouth examination. Methods Gingival bleeding at probing among adolescents (n = 339) and young adults (n = 720) and dental calculus and periodontal probing depth among young adults were assessed using full-mouth examinations and four partial protocols: Ramfjord teeth (RT), community periodontal index (CPI), and two random diagonal quadrants (1 and 3, 2 and 4). Socioeconomic, demographic, and periodontal health-related variables were also collected. Sensitivity, absolute and relative bias, and inflation factors were calculated. Prevalence ratio for each periodontal outcome for the risk factors was estimated. Results Two diagonal quadrants showed better accuracy; RT had the worst, whereas CPI presented an intermediate pattern when compared to full-mouth examination. For bleeding assessment in adolescence, RT and CPI underestimated by 18.4% and 16.2%, respectively, the true outcome prevalence, whereas among young adults, all partial protocols underestimated the prevalence. All partial protocols presented similar magnitude of association measures for all investigated periodontal potential risk factors. Conclusion Two diagonal quadrants protocol may be effective in identifying the risk factors for the most relevant periodontal outcomes in adolescence and in young adulthood. PMID:21859320
Peres, Marco A; Peres, Karen G; Cascaes, Andreia M; Correa, Marcos B; Demarco, Flávio F; Hallal, Pedro C; Horta, Bernardo L; Gigante, Denise P; Menezes, Ana B
2012-03-01
Most studies comparing prevalence of periodontal disease and risk factors by using partial protocols were performed in adult populations, with several studies being conducted in clinical settings. The aim of this study is to assess the accuracy of partial protocols in estimating the prevalence of periodontal outcomes in adolescents and young adults from two population-based birth cohorts from Pelotas, Brazil, and to assess differences in the estimation and strength of the effect measures when partial protocols are adopted compared to full-mouth examination. Gingival bleeding at probing among adolescents (n = 339) and young adults (n = 720) and dental calculus and periodontal probing depth among young adults were assessed using full-mouth examinations and four partial protocols: Ramfjord teeth (RT), community periodontal index (CPI), and two random diagonal quadrants (1 and 3, 2 and 4). Socioeconomic, demographic, and periodontal health-related variables were also collected. Sensitivity, absolute and relative bias, and inflation factors were calculated. Prevalence ratio for each periodontal outcome for the risk factors was estimated. Two diagonal quadrants showed better accuracy; RT had the worst, whereas CPI presented an intermediate pattern when compared to full-mouth examination. For bleeding assessment in adolescence, RT and CPI underestimated by 18.4% and 16.2%, respectively, the true outcome prevalence, whereas among young adults, all partial protocols underestimated the prevalence. All partial protocols presented similar magnitude of association measures for all investigated periodontal potential risk factors. Two diagonal quadrants protocol may be effective in identifying the risk factors for the most relevant periodontal outcomes in adolescence and in young adulthood.
Nagayama, Y; Nakaura, T; Oda, S; Tsuji, A; Urata, J; Furusawa, M; Tanoue, S; Utsunomiya, D; Yamashita, Y
2018-02-01
To perform an intra-individual investigation of the usefulness of a contrast medium (CM) and radiation dose-reduction protocol using single-source computed tomography (CT) combined with 100 kVp and sinogram-affirmed iterative reconstruction (SAFIRE) for whole-body CT (WBCT; chest-abdomen-pelvis CT) in oncology patients. Forty-three oncology patients who had undergone WBCT under both 120 and 100 kVp protocols at different time points (mean interscan intervals: 98 days) were included retrospectively. The CM doses for the 120 and 100 kVp protocols were 600 and 480 mg iodine/kg, respectively; 120 kVp images were reconstructed with filtered back-projection (FBP), whereas 100 kVp images were reconstructed with FBP (100 kVp-F) and the SAFIRE (100 kVp-S). The size-specific dose estimate (SSDE), iodine load and image quality of each protocol were compared. The SSDE and iodine load of 100 kVp protocol were 34% and 21%, respectively, lower than of 120 kVp protocol (SSDE: 10.6±1.1 versus 16.1±1.8 mGy; iodine load: 24.8±4versus 31.5±5.5 g iodine, p<0.01). Contrast enhancement, objective image noise, contrast-to-noise-ratio, and visual score of 100 kVp-S were similar to or better than of 120 kVp protocol. Compared with the 120 kVp protocol, the combined use of 100 kVp and SAFIRE in WBCT for oncology assessment with an SSCT facilitated substantial reduction in the CM and radiation dose while maintaining image quality. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Kawakami, Shuji; Hasegawa, Takuya; Imachi, Hiroyuki; Yamaguchi, Takashi; Harada, Hideki; Ohashi, Akiyoshi; Kubota, Kengo
2012-02-01
In situ detection of functional genes with single-cell resolution is currently of interest to microbiologists. Here, we developed a two-pass tyramide signal amplification (TSA)-fluorescence in situ hybridization (FISH) protocol with PCR-derived polynucleotide probes for the detection of single-copy genes in prokaryotic cells. The mcrA gene and the apsA gene in methanogens and sulfate-reducing bacteria, respectively, were targeted. The protocol showed bright fluorescence with a good signal-to-noise ratio and achieved a high efficiency of detection (>98%). The discrimination threshold was approximately 82-89% sequence identity. Microorganisms possessing the mcrA or apsA gene in anaerobic sludge samples were successfully detected by two-pass TSA-FISH with polynucleotide probes. The developed protocol is useful for identifying single microbial cells based on functional gene sequences. Copyright © 2011 Elsevier B.V. All rights reserved.
Frenzel, S.A.
1996-01-01
Ninety-one stream sites in central Nebraska were classified into four clusters on the basis of a cluster analysis (TWINSPAN) of macroinvertebrate data. Rapid bioassessment protocol scores for macroinvertebrate species were significantly different among sites grouped by teh first division into two clusters. This division may have distinguished sites on the basis of water-quality imparement. Individual metrics that differed between clusters of sites were the Hilsenhoff Biotic Index, the number of Ephemeroptera, Plecoptera, and Trichoptera (EPT) taxa, and the ratio of individuals in EPT to Chironomidae taxa. Canonical correspondence analysis of 57 of 91 sites showed that stream width, site altitude, latitude, soil permeability, water temperature, and mean annual precipitation were the most important environmental variables describing variance in the species-environment relation. Stream width and soil permeability reflected streamflow characteristics of a site, whereas site altitude and latitude were factors related to general climatic conditions. Mean annual precipitation related to both streamflow and climatic conditions.
Asiimwe, Stephen; Oloya, James; Song, Xiao; Whalen, Christopher C
2014-12-01
Unsupervised HIV self-testing (HST) has potential to increase knowledge of HIV status; however, its accuracy is unknown. To estimate the accuracy of unsupervised HST in field settings in Uganda, we performed a non-blinded, randomized controlled, non-inferiority trial of unsupervised compared with supervised HST among selected high HIV risk fisherfolk (22.1 % HIV Prevalence) in three fishing villages in Uganda between July and September 2013. The study enrolled 246 participants and randomized them in a 1:1 ratio to unsupervised HST or provider-supervised HST. In an intent-to-treat analysis, the HST sensitivity was 90 % in the unsupervised arm and 100 % among the provider-supervised, yielding a difference 0f -10 % (90 % CI -21, 1 %); non-inferiority was not shown. In a per protocol analysis, the difference in sensitivity was -5.6 % (90 % CI -14.4, 3.3 %) and did show non-inferiority. We conclude that unsupervised HST is feasible in rural Africa and may be non-inferior to provider-supervised HST.
Analysis of splicing complexes on native gels.
Ares, Manuel
2013-10-01
Splicing requires a complex set of ATP-dependent macromolecular associations that lead to the rearrangement of just a few covalent bonds in the pre-mRNA substrate. Seeing only the covalent bonds breaking and forming is seeing only a very small part of the process. Analysis of native splicing complexes into which the radiolabeled substrate has been assembled, but not necessarily completely reacted, has provided a good understanding of the process. This protocol describes a gel method for detecting and analyzing yeast splicing complexes formed in vitro on a radiolabeled pre-mRNA substrate. Complexes formed during the splicing reaction are quenched by dilution and addition of an excess of RNA, which is thought to strip nonspecifically bound proteins from the labeled substrate RNA. After loading on a low-percentage, low-cross-linking ratio composite agarose-acrylamide gel (in 10% glycerol), labeled bands are detected. These can be extracted and shown to contain small nuclear RNAs (snRNAs) and partly reacted pre-mRNA.
Santos, Ana A. S.; Silva, Anne K. F.; Vanderlei, Franciele M.; Christofaro, Diego G. D.; Gonçalves, Aline F. L.; Vanderlei, Luiz C. M.
2016-01-01
ABSTRACT Background Cardiac risk stratification is related to the risk of the occurrence of events induced by exercise. Despite the existence of several protocols to calculate risk stratification, studies indicating that there is similarity between these protocols are still unknown. Objective To evaluate the agreement between the existing protocols on cardiac risk rating in cardiac patients. Method The records of 50 patients from a cardiac rehabilitation program were analyzed, from which the following information was extracted: age, sex, weight, height, clinical diagnosis, medical history, risk factors, associated diseases, and the results from the most recent laboratory and complementary tests performed. This information was used for risk stratification of the patients in the protocols of the American College of Sports Medicine, the Brazilian Society of Cardiology, the American Heart Association, the protocol designed by Frederic J. Pashkow, the American Association of Cardiovascular and Pulmonary Rehabilitation, the Société Française de Cardiologie, and the Sociedad Española de Cardiología. Descriptive statistics were used to characterize the sample and the analysis of agreement between the protocols was calculated using the Kappa coefficient. Differences were considered with a significance level of 5%. Results Of the 21 analyses of agreement, 12 were considered significant between the protocols used for risk classification, with nine classified as moderate and three as low. No agreements were classified as excellent. Different proportions were observed in each risk category, with significant differences between the protocols for all risk categories. Conclusion The agreements between the protocols were considered low and moderate and the risk proportions differed between protocols. PMID:27556385
Judges' Agreement and Disagreement Patterns When Encoding Verbal Protocols.
ERIC Educational Resources Information Center
Schael, Jocelyne; Dionne, Jean-Paul
The basis of agreement or disagreement among judges/evaluators when applying a coding scheme to concurrent verbal protocols was studied. The sample included 20 university graduates, from varied backgrounds; 10 subjects had and 10 subjects did not have experience in protocol analysis. The total sample was divided into four balanced groups according…
Teaching Integrity in Empirical Research: A Protocol for Documenting Data Management and Analysis
ERIC Educational Resources Information Center
Ball, Richard; Medeiros, Norm
2012-01-01
This article describes a protocol the authors developed for teaching undergraduates to document their statistical analyses for empirical research projects so that their results are completely reproducible and verifiable. The protocol is guided by the principle that the documentation prepared to accompany an empirical research project should be…
An Overview and Analysis of Mobile Internet Protocols in Cellular Environments.
ERIC Educational Resources Information Center
Chao, Han-Chieh
2001-01-01
Notes that cellular is the inevitable future architecture for the personal communication service system. Discusses the current cellular support based on Mobile Internet Protocol version 6 (Ipv6) and points out the shortfalls of using Mobile IP. Highlights protocols especially for mobile management schemes which can optimize a high-speed mobile…
Continuous variable quantum cryptography using coherent states.
Grosshans, Frédéric; Grangier, Philippe
2002-02-04
We propose several methods for quantum key distribution (QKD) based on the generation and transmission of random distributions of coherent or squeezed states, and we show that they are secure against individual eavesdropping attacks. These protocols require that the transmission of the optical line between Alice and Bob is larger than 50%, but they do not rely on "sub-shot-noise" features such as squeezing. Their security is a direct consequence of the no-cloning theorem, which limits the signal-to-noise ratio of possible quantum measurements on the transmission line. Our approach can also be used for evaluating various QKD protocols using light with Gaussian statistics.
Wang, Jindong; Qin, Xiaojuan; Jiang, Yinzhu; Wang, Xiaojing; Chen, Liwei; Zhao, Feng; Wei, Zhengjun; Zhang, Zhiming
2016-04-18
A proof-of-principle demonstration of a one-way polarization encoding quantum key distribution (QKD) system is demonstrated. This approach can automatically compensate for birefringence and phase drift. This is achieved by constructing intrinsically stable polarization-modulated units (PMUs) to perform the encoding and decoding, which can be used with four-state protocol, six-state protocol, and the measurement-device-independent (MDI) scheme. A polarization extinction ratio of about 30 dB was maintained for several hours over a 50 km optical fiber without any adjustments to our setup, which evidences its potential for use in practical applications.
TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Chan, F; Newman, B
2014-06-15
Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less
On the Analysis of Two-Person Problem Solving Protocols.
ERIC Educational Resources Information Center
Schoenfeld, Alan H.
Methodological issues in the use of protocol analysis for research into human problem solving processes are examined through a case study in which two students were videotaped as they worked together to solve mathematical problems "out loud." The students' chosen strategic or executive behavior in examining and solving a problem was…
Analysis of the Impacts of an Early Start for Compliance with the Kyoto Protocol
1999-01-01
This report describes the Energy Information Administration's analysis of the impacts of an early start, using the same methodology as in Impacts of the Kyoto Protocol on U.S. Energy Markets and Economic Activity, with only those changes in assumptions caused by the early start date.
Protocol Analysis as a Method for Analyzing Conversational Data.
ERIC Educational Resources Information Center
Aleman, Carlos G.; Vangelisti, Anita L.
Protocol analysis, a technique that uses people's verbal reports about their cognitions as they engage in an assigned task, has been used in a number of applications to provide insight into how people mentally plan, assess, and carry out those assignments. Using a system of networked computers where actors communicate with each other over…
Automatic Coding of Dialogue Acts in Collaboration Protocols
ERIC Educational Resources Information Center
Erkens, Gijsbert; Janssen, Jeroen
2008-01-01
Although protocol analysis can be an important tool for researchers to investigate the process of collaboration and communication, the use of this method of analysis can be time consuming. Hence, an automatic coding procedure for coding dialogue acts was developed. This procedure helps to determine the communicative function of messages in online…
Establishing an effective TMS protocol for craving in substance addiction: Is it possible?
Enokibara, Mailu; Trevizol, Alisson; Shiozawa, Pedro; Cordeiro, Quirino
2016-01-01
Repetitive transcranial magnetic stimulation (TMS) is a non-invasive tool with known therapeutic efficacy in various neuropsychiatric disorders, such as depression, schizophrenia, mania, and anxiety disorders. We hereby, briefly present a brief review and meta-analysis on the use of TMS for craving in substance addiction. We present our brief review and meta-analysis following the recommendations of the Cochrane group. A total of eight randomized controlled trials fulfilled eligibility criteria and were selected. A total of 199 patients were studied. We found active stimulation to be superior than sham protocols only for trials focused on right DLPFC (with Hedge's g = 1.48; ES (95%CI: 0.126-2.834), p = 0.032. Main meta-analysis limitations include small number of studies, high heterogeneity among studies, and high publication bias. However challenging, our exploratory analysis underscored the amelioration of craving in substance addiction for trials using high frequency TMS protocols over the right DLPFC. We hereby, propose the use of this particular TMS protocol as a promising tool in clinical research. © American Academy of Addiction Psychiatry.