The Sequential Probability Ratio Test and Binary Item Response Models
ERIC Educational Resources Information Center
Nydick, Steven W.
2014-01-01
The sequential probability ratio test (SPRT) is a common method for terminating item response theory (IRT)-based adaptive classification tests. To decide whether a classification test should stop, the SPRT compares a simple log-likelihood ratio, based on the classification bound separating two categories, to prespecified critical values. As has…
Zero-inflated Poisson model based likelihood ratio test for drug safety signal detection.
Huang, Lan; Zheng, Dan; Zalkikar, Jyoti; Tiwari, Ram
2017-02-01
In recent decades, numerous methods have been developed for data mining of large drug safety databases, such as Food and Drug Administration's (FDA's) Adverse Event Reporting System, where data matrices are formed by drugs such as columns and adverse events as rows. Often, a large number of cells in these data matrices have zero cell counts and some of them are "true zeros" indicating that the drug-adverse event pairs cannot occur, and these zero counts are distinguished from the other zero counts that are modeled zero counts and simply indicate that the drug-adverse event pairs have not occurred yet or have not been reported yet. In this paper, a zero-inflated Poisson model based likelihood ratio test method is proposed to identify drug-adverse event pairs that have disproportionately high reporting rates, which are also called signals. The maximum likelihood estimates of the model parameters of zero-inflated Poisson model based likelihood ratio test are obtained using the expectation and maximization algorithm. The zero-inflated Poisson model based likelihood ratio test is also modified to handle the stratified analyses for binary and categorical covariates (e.g. gender and age) in the data. The proposed zero-inflated Poisson model based likelihood ratio test method is shown to asymptotically control the type I error and false discovery rate, and its finite sample performance for signal detection is evaluated through a simulation study. The simulation results show that the zero-inflated Poisson model based likelihood ratio test method performs similar to Poisson model based likelihood ratio test method when the estimated percentage of true zeros in the database is small. Both the zero-inflated Poisson model based likelihood ratio test and likelihood ratio test methods are applied to six selected drugs, from the 2006 to 2011 Adverse Event Reporting System database, with varying percentages of observed zero-count cells.
DOT National Transportation Integrated Search
2010-11-01
The resilient modulus and Poissons ratio of base and sublayers in highway use are : important parameters in design and quality control process. The currently used techniques : include CBR (California Bearing Ratio) test, resilient modulus test,...
Cai, Zhen-bing; Zhao, Lei; Zhang, Xu; Yue, Wen; Zhu, Min-hao
2016-01-01
A ball-on-plate wear test was employed to investigate the effectiveness of graphene (GP) nanoparticles dispersed in a synthetic-oil-based lubricant in reducing wear. The effect by area ratio of elliptically shaped dimple textures and elevated temperatures were also explored. Pure PAO4 based oil and a mixture of this oil with 0.01 wt% GP were compared as lubricants. At pit area ratio of 5%, GP-base oil effectively reduced friction and wear, especially at 60 and 100°C. Under pure PAO4 oil lubrication, the untextured surfaces gained low friction coefficients (COFs) and wear rates under 60 and 100°C. With increasing laser—texture area ratio, the COF and wear rate decreased at 25 and 150°C but increased at 60 and 100°C. Under the GP-based oil lubrication, the textured surface with 5% area ratio achieved the lowest COF among those of the area ratios tested at all test temperatures. Meanwhile, the textured surface with 20% area ratio obtained the highest COF among those of the area ratios. With the joint action of GP and texture, the textured surface with 10% area ratio exhibited the best anti-wear performance among all of the textured surfaces at all test temperatures. PMID:27054762
Meta-analysis: accuracy of rapid tests for malaria in travelers returning from endemic areas.
Marx, Arthur; Pewsner, Daniel; Egger, Matthias; Nüesch, Reto; Bucher, Heiner C; Genton, Blaise; Hatz, Christoph; Jüni, Peter
2005-05-17
Microscopic diagnosis of malaria is unreliable outside specialized centers. Rapid tests have become available in recent years, but their accuracy has not been assessed systematically. To determine the accuracy of rapid diagnostic tests for ruling out malaria in nonimmune travelers returning from malaria-endemic areas. The authors searched MEDLINE, EMBASE, CAB Health, and CINAHL (1988 to September 2004); hand-searched conference proceedings; checked reference lists; and contacted experts and manufacturers. Diagnostic accuracy studies in nonimmune individuals with suspected malaria were included if they compared rapid tests with expert microscopic examination or polymerase chain reaction tests. Data on study and patient characteristics and results were extracted in duplicate. The main outcome was the likelihood ratio for a negative test result (negative likelihood ratio) for Plasmodium falciparum malaria. Likelihood ratios were combined by using random-effects meta-analysis, stratified by the antigen targeted (histidine-rich protein-2 [HRP-2] or parasite lactate dehydrogenase [LDH]) and by test generation. Nomograms of post-test probabilities were constructed. The authors included 21 studies and 5747 individuals. For P. falciparum, HRP-2-based tests were more accurate than parasite LDH-based tests: Negative likelihood ratios were 0.08 and 0.13, respectively (P = 0.019 for difference). Three-band HRP-2 tests had similar negative likelihood ratios but higher positive likelihood ratios compared with 2-band tests (34.7 vs. 98.5; P = 0.003). For P. vivax, negative likelihood ratios tended to be closer to 1.0 for HRP-2-based tests than for parasite LDH-based tests (0.24 vs. 0.13; P = 0.22), but analyses were based on a few heterogeneous studies. Negative likelihood ratios for the diagnosis of P. malariae or P. ovale were close to 1.0 for both types of tests. In febrile travelers returning from sub-Saharan Africa, the typical probability of P. falciparum malaria is estimated at 1.1% (95% CI, 0.6% to 1.9%) after a negative 3-band HRP-2 test result and 97% (CI, 92% to 99%) after a positive test result. Few studies evaluated 3-band HRP-2 tests. The evidence is also limited for species other than P. falciparum because of the few available studies and their more heterogeneous results. Further studies are needed to determine whether the use of rapid diagnostic tests improves outcomes in returning travelers with suspected malaria. Rapid malaria tests may be a useful diagnostic adjunct to microscopy in centers without major expertise in tropical medicine. Initial decisions on treatment initiation and choice of antimalarial drugs can be based on travel history and post-test probabilities after rapid testing. Expert microscopy is still required for species identification and confirmation.
Wald Sequential Probability Ratio Test for Space Object Conjunction Assessment
NASA Technical Reports Server (NTRS)
Carpenter, James R.; Markley, F Landis
2014-01-01
This paper shows how satellite owner/operators may use sequential estimates of collision probability, along with a prior assessment of the base risk of collision, in a compound hypothesis ratio test to inform decisions concerning collision risk mitigation maneuvers. The compound hypothesis test reduces to a simple probability ratio test, which appears to be a novel result. The test satisfies tolerances related to targeted false alarm and missed detection rates. This result is independent of the method one uses to compute the probability density that one integrates to compute collision probability. A well-established test case from the literature shows that this test yields acceptable results within the constraints of a typical operational conjunction assessment decision timeline. Another example illustrates the use of the test in a practical conjunction assessment scenario based on operations of the International Space Station.
A more powerful test based on ratio distribution for retention noninferiority hypothesis.
Deng, Ling; Chen, Gang
2013-03-11
Rothmann et al. ( 2003 ) proposed a method for the statistical inference of fraction retention noninferiority (NI) hypothesis. A fraction retention hypothesis is defined as a ratio of the new treatment effect verse the control effect in the context of a time to event endpoint. One of the major concerns using this method in the design of an NI trial is that with a limited sample size, the power of the study is usually very low. This makes an NI trial not applicable particularly when using time to event endpoint. To improve power, Wang et al. ( 2006 ) proposed a ratio test based on asymptotic normality theory. Under a strong assumption (equal variance of the NI test statistic under null and alternative hypotheses), the sample size using Wang's test was much smaller than that using Rothmann's test. However, in practice, the assumption of equal variance is generally questionable for an NI trial design. This assumption is removed in the ratio test proposed in this article, which is derived directly from a Cauchy-like ratio distribution. In addition, using this method, the fundamental assumption used in Rothmann's test, that the observed control effect is always positive, that is, the observed hazard ratio for placebo over the control is greater than 1, is no longer necessary. Without assuming equal variance under null and alternative hypotheses, the sample size required for an NI trial can be significantly reduced if using the proposed ratio test for a fraction retention NI hypothesis.
DEVELOPMENT OF AN ARMY STATIONARY AXLE TEST STAND FOR LUBRICANT EFFICIENCY EVALUATION-PART II
2017-01-13
value was estimated based on the engines maximum peak torque output, multiplied by the transmissions 1st gear ratio, high range transfer case ratio...efficiency test stand to allow for laboratory based investigation of Fuel Efficient Gear Oils (FEGO) and their impact on vehicle efficiency. Development...their impact on vehicle efficiency. The test stand was designed and developed with the following goals: • Provide a lower cost alternative for
Vexler, Albert; Tanajian, Hovig; Hutson, Alan D
In practice, parametric likelihood-ratio techniques are powerful statistical tools. In this article, we propose and examine novel and simple distribution-free test statistics that efficiently approximate parametric likelihood ratios to analyze and compare distributions of K groups of observations. Using the density-based empirical likelihood methodology, we develop a Stata package that applies to a test for symmetry of data distributions and compares K -sample distributions. Recognizing that recent statistical software packages do not sufficiently address K -sample nonparametric comparisons of data distributions, we propose a new Stata command, vxdbel, to execute exact density-based empirical likelihood-ratio tests using K samples. To calculate p -values of the proposed tests, we use the following methods: 1) a classical technique based on Monte Carlo p -value evaluations; 2) an interpolation technique based on tabulated critical values; and 3) a new hybrid technique that combines methods 1 and 2. The third, cutting-edge method is shown to be very efficient in the context of exact-test p -value computations. This Bayesian-type method considers tabulated critical values as prior information and Monte Carlo generations of test statistic values as data used to depict the likelihood function. In this case, a nonparametric Bayesian method is proposed to compute critical values of exact tests.
NASA Astrophysics Data System (ADS)
Ma, Longzhou; Roy, Shawoon K.
2013-04-01
The fatigue crack propagation (FCP) behavior of two solid-solution-strengthened Ni-based superalloys, INCONEL 617 and HAYNES 230, were studied simultaneously in laboratory air using a constant stress intensity factor (K)-controlled mode with different load ratios (R-ratio) at 700 °C. The FCP tests were performed in both cycle and time-dependent FCP domains to examine the effect of R-ratio on the FCP rate, da/dn. For cycle-dependent FCP test, a 1-s sinusoidal fatigue was applied for a compact tension (CT) specimen of INCONEL 617 and HAYNES 230 to measure their FCP rates. For time-dependent FCP test, a 3-s sinusoidal fatigue with a hold time of 300 s at maximum load was applied. Both cycle/time-dependent FCP behaviors were characterized and analyzed. The results showed that increasing R-ratio would introduce the fatigue incubation and decrease the FCP rates at cycle-dependent FCP tests. On the contrary, fatigue incubation was not observed at time-dependent FCP tests for both INCONEL 617 and HAYNES 230 at each tested R-ratio, suggesting that association of maximum load (Kmax) with crack tip open displacement (CTOD) and environmental factor governed the FCP process. Also, for time-dependent FCP, HAYNES 230 showed lower FCP rates than INCONEL 617 regardless of R-ratio. However, for cycle-dependent FCP, HAYNES 230 showed the lower FCP rates only at high R-ratios. Fracture surface of specimens were examined using SEM to investigate the cracking mechanism under cycle/time-dependent FCP condition with various R-ratios.
Defense Contracting: Key Data Not Routinely Used in Progress Payment Reviews
1992-01-14
the amount of pay- By .ments based on the fair value of undelivered work. Contractors may Distibtion ] submit requests for progress payments monthly and...exceed the Federal Acquisition Regulation limitations. These checks are based on contractor data and include the fair value and the loss ratio tests. The... fair value test is intended to ensure that progress payments for work in process do not exceed the value of that work. The loss ratio test is intended
Sinharay, Sandip
2017-09-01
Benefiting from item preknowledge is a major type of fraudulent behavior during educational assessments. Belov suggested the posterior shift statistic for detection of item preknowledge and showed its performance to be better on average than that of seven other statistics for detection of item preknowledge for a known set of compromised items. Sinharay suggested a statistic based on the likelihood ratio test for detection of item preknowledge; the advantage of the statistic is that its null distribution is known. Results from simulated and real data and adaptive and nonadaptive tests are used to demonstrate that the Type I error rate and power of the statistic based on the likelihood ratio test are very similar to those of the posterior shift statistic. Thus, the statistic based on the likelihood ratio test appears promising in detecting item preknowledge when the set of compromised items is known.
Strahm, E; Emery, C; Saugy, M; Dvorak, J; Saudan, C
2009-12-01
The determination of the carbon isotope ratio in androgen metabolites has been previously shown to be a reliable, direct method to detect testosterone misuse in the context of antidoping testing. Here, the variability in the 13C/12C ratios in urinary steroids in a widely heterogeneous cohort of professional soccer players residing in different countries (Argentina, Italy, Japan, South Africa, Switzerland and Uganda) is examined. Carbon isotope ratios of selected androgens in urine specimens were determined using gas chromatography/combustion/isotope ratio mass spectrometry (GC-C-IRMS). Urinary steroids in Italian and Swiss populations were found to be enriched in 13C relative to other groups, reflecting higher consumption of C3 plants in these two countries. Importantly, detection criteria based on the difference in the carbon isotope ratio of androsterone and pregnanediol for each population were found to be well below the established threshold value for positive cases. The results obtained with the tested diet groups highlight the importance of adapting the criteria if one wishes to increase the sensitivity of exogenous testosterone detection. In addition, confirmatory tests might be rendered more efficient by combining isotope ratio mass spectrometry with refined interpretation criteria for positivity and subject-based profiling of steroids.
A temporal discriminability account of children's eyewitness suggestibility.
Bright-Paul, Alexandra; Jarrold, Christopher
2009-07-01
Children's suggestibility is typically measured using a three-stage 'event-misinformation-test' procedure. We examined whether suggestibility is influenced by the time delays imposed between these stages, and in particular whether the temporal discriminability of sources (event and misinformation) predicts performance. In a novel approach, the degree of source discriminability was calculated as the relative magnitude of two intervals (the ratio of event-misinformation and misinformation-test intervals), based on an adaptation of existing 'ratio-rule' accounts of memory. Five-year-olds (n =150) watched an event, and were exposed to misinformation, before memory for source was tested. The absolute event-test delay (12 versus 24 days) and the 'ratio' of event-misinformation/misinformation-test intervals (11:1, 3:1, 1:1, 1:3 and 1:11) were manipulated across participants. The temporal discriminability of sources, measured by the ratio, was indeed a strong predictor of suggestibility. Most importantly, if the ratio was constant (e.g. 18/6 versus 9/3 days), performance was remarkably similar despite variations in absolute delay (e.g. 24 versus 12 days). This intriguing finding not only extends the ratio-rule of distinctiveness to misinformation paradigms, but also serves to illustrate a new empirical means of differentiating between explanations of suggestibility based on interference between sources and disintegration of source information over time.
Computerized Classification Testing with the Rasch Model
ERIC Educational Resources Information Center
Eggen, Theo J. H. M.
2011-01-01
If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…
EHR based Genetic Testing Knowledge Base (iGTKB) Development
2015-01-01
Background The gap between a large growing number of genetic tests and a suboptimal clinical workflow of incorporating these tests into regular clinical practice poses barriers to effective reliance on advanced genetic technologies to improve quality of healthcare. A promising solution to fill this gap is to develop an intelligent genetic test recommendation system that not only can provide a comprehensive view of genetic tests as education resources, but also can recommend the most appropriate genetic tests to patients based on clinical evidence. In this study, we developed an EHR based Genetic Testing Knowledge Base for Individualized Medicine (iGTKB). Methods We extracted genetic testing information and patient medical records from EHR systems at Mayo Clinic. Clinical features have been semi-automatically annotated from the clinical notes by applying a Natural Language Processing (NLP) tool, MedTagger suite. To prioritize clinical features for each genetic test, we compared odds ratio across four population groups. Genetic tests, genetic disorders and clinical features with their odds ratios have been applied to establish iGTKB, which is to be integrated into the Genetic Testing Ontology (GTO). Results Overall, there are five genetic tests operated with sample size greater than 100 in 2013 at Mayo Clinic. A total of 1,450 patients who was tested by one of the five genetic tests have been selected. We assembled 243 clinical features from the Human Phenotype Ontology (HPO) for these five genetic tests. There are 60 clinical features with at least one mention in clinical notes of patients taking the test. Twenty-eight clinical features with high odds ratio (greater than 1) have been selected as dominant features and deposited into iGTKB with their associated information about genetic tests and genetic disorders. Conclusions In this study, we developed an EHR based genetic testing knowledge base, iGTKB. iGTKB will be integrated into the GTO by providing relevant clinical evidence, and ultimately to support development of genetic testing recommendation system, iGenetics. PMID:26606281
EHR based Genetic Testing Knowledge Base (iGTKB) Development.
Zhu, Qian; Liu, Hongfang; Chute, Christopher G; Ferber, Matthew
2015-01-01
The gap between a large growing number of genetic tests and a suboptimal clinical workflow of incorporating these tests into regular clinical practice poses barriers to effective reliance on advanced genetic technologies to improve quality of healthcare. A promising solution to fill this gap is to develop an intelligent genetic test recommendation system that not only can provide a comprehensive view of genetic tests as education resources, but also can recommend the most appropriate genetic tests to patients based on clinical evidence. In this study, we developed an EHR based Genetic Testing Knowledge Base for Individualized Medicine (iGTKB). We extracted genetic testing information and patient medical records from EHR systems at Mayo Clinic. Clinical features have been semi-automatically annotated from the clinical notes by applying a Natural Language Processing (NLP) tool, MedTagger suite. To prioritize clinical features for each genetic test, we compared odds ratio across four population groups. Genetic tests, genetic disorders and clinical features with their odds ratios have been applied to establish iGTKB, which is to be integrated into the Genetic Testing Ontology (GTO). Overall, there are five genetic tests operated with sample size greater than 100 in 2013 at Mayo Clinic. A total of 1,450 patients who was tested by one of the five genetic tests have been selected. We assembled 243 clinical features from the Human Phenotype Ontology (HPO) for these five genetic tests. There are 60 clinical features with at least one mention in clinical notes of patients taking the test. Twenty-eight clinical features with high odds ratio (greater than 1) have been selected as dominant features and deposited into iGTKB with their associated information about genetic tests and genetic disorders. In this study, we developed an EHR based genetic testing knowledge base, iGTKB. iGTKB will be integrated into the GTO by providing relevant clinical evidence, and ultimately to support development of genetic testing recommendation system, iGenetics.
Sex ratios in the two Germanies: a test of the economic stress hypothesis.
Catalano, Ralph A
2003-09-01
Literature describing temporal variation in the secondary sex ratio among humans reports an association between population stressors and declines in the odds of male birth. Explanations of this phenomenon draw on reports that stressed females spontaneously abort male more than female fetuses, and that stressed males exhibit reduced sperm motility. This work has led to the argument that population stress induced by a declining economy reduces the human sex ratio. No direct test of this hypothesis appears in the literature. Here, a test is offered based on a comparison of the sex ratio in East and West Germany for the years 1946 to 1999. The theory suggests that the East German sex ratio should be lower in 1991, when East Germany's economy collapsed, than expected from its own history and from the sex ratio in West Germany. The hypothesis is tested using time-series modelling methods. The data support the hypothesis. The sex ratio in East Germany was at its lowest in 1991. This first direct test supports the hypothesis that economic decline reduces the human sex ratio.
Chan, Siew Foong; Deeks, Jonathan J; Macaskill, Petra; Irwig, Les
2008-01-01
To compare three predictive models based on logistic regression to estimate adjusted likelihood ratios allowing for interdependency between diagnostic variables (tests). This study was a review of the theoretical basis, assumptions, and limitations of published models; and a statistical extension of methods and application to a case study of the diagnosis of obstructive airways disease based on history and clinical examination. Albert's method includes an offset term to estimate an adjusted likelihood ratio for combinations of tests. Spiegelhalter and Knill-Jones method uses the unadjusted likelihood ratio for each test as a predictor and computes shrinkage factors to allow for interdependence. Knottnerus' method differs from the other methods because it requires sequencing of tests, which limits its application to situations where there are few tests and substantial data. Although parameter estimates differed between the models, predicted "posttest" probabilities were generally similar. Construction of predictive models using logistic regression is preferred to the independence Bayes' approach when it is important to adjust for dependency of tests errors. Methods to estimate adjusted likelihood ratios from predictive models should be considered in preference to a standard logistic regression model to facilitate ease of interpretation and application. Albert's method provides the most straightforward approach.
Plastic Stress-strain Relations for 75S-T6 Aluminum Alloy Subjected to Biaxial Tensile Stresses
NASA Technical Reports Server (NTRS)
Marin, Joseph; Ulrich, B H; Hughes, W P
1951-01-01
In this investigation, the material tested was a 75S-T6 aluminum alloy and the stresses were essentially biaxial and tensile. The biaxial tensile stresses were produced in a specially designed testing machine by subjecting a thin-walled tubular specimen to axial tension and internal pressure. Plastic stress-strain relations for various biaxial stress conditions were obtained using a clip-type SR-4 strain gage. Three types of tests were made: Constant-stress-ratio tests, variable-stress-ratio tests, and special tests. The constant-stress-ratio test results gave control data and showed the influence of biaxial stresses on the yield, fracture, and ultimate strength of the material. By means of the variable-stress-ratio tests, it is possible to determine whether there is any significant difference between the flow and deformation type of theory. Finally, special tests were conducted to check specific assumptions made in the theories of plastic flow. The constant-stress-ratio tests show that the deformation theory based on the octahedral, effective; or significant stress-strain relations is in approximate agreement with the test results. The variable-stress-ratio tests show that both the deformation and flow theory are in equally good agreement with the test results.
Strahm, E; Emery, C; Saugy, M; Dvorak, J; Saudan, C
2009-01-01
Background and objectives: The determination of the carbon isotope ratio in androgen metabolites has been previously shown to be a reliable, direct method to detect testosterone misuse in the context of antidoping testing. Here, the variability in the 13C/12C ratios in urinary steroids in a widely heterogeneous cohort of professional soccer players residing in different countries (Argentina, Italy, Japan, South Africa, Switzerland and Uganda) is examined. Methods: Carbon isotope ratios of selected androgens in urine specimens were determined using gas chromatography/combustion/isotope ratio mass spectrometry (GC-C-IRMS). Results: Urinary steroids in Italian and Swiss populations were found to be enriched in 13C relative to other groups, reflecting higher consumption of C3 plants in these two countries. Importantly, detection criteria based on the difference in the carbon isotope ratio of androsterone and pregnanediol for each population were found to be well below the established threshold value for positive cases. Conclusions: The results obtained with the tested diet groups highlight the importance of adapting the criteria if one wishes to increase the sensitivity of exogenous testosterone detection. In addition, confirmatory tests might be rendered more efficient by combining isotope ratio mass spectrometry with refined interpretation criteria for positivity and subject-based profiling of steroids. PMID:19549614
Park, Sang Hyuk; Kim, So-Young; Lee, Woochang; Chun, Sail; Min, Won-Ki
2012-09-01
Many laboratories use 4 delta check methods: delta difference, delta percent change, rate difference, and rate percent change. However, guidelines regarding decision criteria for selecting delta check methods have not yet been provided. We present new decision criteria for selecting delta check methods for each clinical chemistry test item. We collected 811,920 and 669,750 paired (present and previous) test results for 27 clinical chemistry test items from inpatients and outpatients, respectively. We devised new decision criteria for the selection of delta check methods based on the ratio of the delta difference to the width of the reference range (DD/RR). Delta check methods based on these criteria were compared with those based on the CV% of the absolute delta difference (ADD) as well as those reported in 2 previous studies. The delta check methods suggested by new decision criteria based on the DD/RR ratio corresponded well with those based on the CV% of the ADD except for only 2 items each in inpatients and outpatients. Delta check methods based on the DD/RR ratio also corresponded with those suggested in the 2 previous studies, except for 1 and 7 items in inpatients and outpatients, respectively. The DD/RR method appears to yield more feasible and intuitive selection criteria and can easily explain changes in the results by reflecting both the biological variation of the test item and the clinical characteristics of patients in each laboratory. We suggest this as a measure to determine delta check methods.
Rocket-Based Combined Cycle Flowpath Testing for Modes 1 and 4
NASA Technical Reports Server (NTRS)
Rice, Tharen
2002-01-01
Under sponsorship of the NASA Glenn Research Center (NASA GRC), the Johns Hopkins University Applied Physics Laboratory (JHU/APL) designed and built a five-inch diameter, Rocket-Based Combined Cycle (RBCC) engine to investigate mode 1 and mode 4 engine performance as well as Mach 4 inlet performance. This engine was designed so that engine area and length ratios were similar to the NASA GRC GTX engine is shown. Unlike the GTX semi-circular engine design, the APL engine is completely axisymmetric. For this design, a traditional rocket thruster was installed inside of the scramjet flowpath, along the engine centerline. A three part test series was conducted to determine Mode I and Mode 4 engine performance. In part one, testing of the rocket thruster alone was accomplished and its performance determined (average Isp efficiency = 90%). In part two, Mode 1 (air-augmented rocket) testing was conducted at a nominal chamber pressure-to-ambient pressure ratio of 100 with the engine inlet fully open. Results showed that there was neither a thrust increment nor decrement over rocket-only thrust during Mode 1 operation. In part three, Mode 4 testing was conducted with chamber pressure-to-ambient pressure ratios lower than desired (80 instead of 600) with the inlet fully closed. Results for this testing showed a performance decrease of 20% as compared to the rocket-only testing. It is felt that these results are directly related to the low pressure ratio tested and not the engine design. During this program, Mach 4 inlet testing was also conducted. For these tests, a moveable centerbody was tested to determine the maximum contraction ratio for the engine design. The experimental results agreed with CFD results conducted by NASA GRC, showing a maximum geometric contraction ratio of approximately 10.5. This report details the hardware design, test setup, experimental results and data analysis associated with the aforementioned tests.
Likelihood-Ratio DIF Testing: Effects of Nonnormality
ERIC Educational Resources Information Center
Woods, Carol M.
2008-01-01
Differential item functioning (DIF) occurs when an item has different measurement properties for members of one group versus another. Likelihood-ratio (LR) tests for DIF based on item response theory (IRT) involve statistically comparing IRT models that vary with respect to their constraints. A simulation study evaluated how violation of the…
Retrieving the aerosol lidar ratio profile by combining ground- and space-based elastic lidars.
Feiyue, Mao; Wei, Gong; Yingying, Ma
2012-02-15
The aerosol lidar ratio is a key parameter for the retrieval of aerosol optical properties from elastic lidar, which changes largely for aerosols with different chemical and physical properties. We proposed a method for retrieving the aerosol lidar ratio profile by combining simultaneous ground- and space-based elastic lidars. The method was tested by a simulated case and a real case at 532 nm wavelength. The results demonstrated that our method is robust and can obtain accurate lidar ratio and extinction coefficient profiles. Our method can be useful for determining the local and global lidar ratio and validating space-based lidar datasets.
Extrusion-mixing compared with hand-mixing of polyether impression materials?
McMahon, Caroline; Kinsella, Daniel; Fleming, Garry J P
2010-12-01
The hypotheses tested were two-fold (a) whether altering the base:catalyst ratio influences working time, elastic recovery and strain in compression properties of a hand-mixed polyether impression material and (b) whether an extrusion-mixed polyether impression material would have a significant advantage over a hand-mixed polyether impression material mixed to the optimum base:catalyst ratio. The polyether was hand-mixed at the optimum (manufacturers recommended) base:catalyst ratios (7:1) and further groups were made by increasing or decreasing the catalyst length by 25%. Additionally specimens were also made from an extrusion-mixed polyether impression material and compared with the optimum hand-mixed base:catalyst ratio. A penetrometer assembly was used to measure the working time (n=5). Five cylindrical specimens for each hand-mixed and extrusion mixed group investigated were employed for elastic recovery and strain in compression testing. Hand-mixing polyether impression materials with 25% more catalyst than that recommended significantly decreased the working time while hand-mixing with 25% less catalyst than that recommended significantly increased the strain in compression. The extrusion-mixed polyether impression material provided similar working time, elastic recovery and strain in compression to the hand-mixed polyether mixed at the optimum base:catalyst ratio.
NASA Astrophysics Data System (ADS)
Stepanov, Eugene V.; Zyrianov, Pavel V.; Miliaev, Valerii A.; Selivanov, Yurii G.; Chizhevskii, Eugene G.; Os'kina, Svetlana; Ivashkin, Vladimir T.; Nikitina, Elena I.
1999-07-01
An analyzer of 13CO2/12CO2 ratio in exhaled air based on lead-salt tunable diode lasers is presented. High accuracy of the carbon isotope ratio detection in exhaled carbon dioxide was achieved with help of very simple optical schematics. It was based on the use of MBE laser diodes operating in pulse mode and on recording the resonance CO2 absorption at 4.2 micrometers . Special fast acquisition electronics and software were applied for spectral data collection and processing. Developed laser system was tested in a clinical train aimed to assessment eradication efficiency in therapy of gastritis associated with Helicobacter pylori infection. Data on the 13C-urea breath test used for P.pylori detection and obtained with tunable diode lasers in the course of the trail was compared with the results of Mass-Spectroscopy analysis and histology observations. The analyzer can be used also for 13CO2/12CO2 ratio detection in exhalation to perform gastroenterology breath test based on using other compounds labeled with stable isotopes.
Wald Sequential Probability Ratio Test for Analysis of Orbital Conjunction Data
NASA Technical Reports Server (NTRS)
Carpenter, J. Russell; Markley, F. Landis; Gold, Dara
2013-01-01
We propose a Wald Sequential Probability Ratio Test for analysis of commonly available predictions associated with spacecraft conjunctions. Such predictions generally consist of a relative state and relative state error covariance at the time of closest approach, under the assumption that prediction errors are Gaussian. We show that under these circumstances, the likelihood ratio of the Wald test reduces to an especially simple form, involving the current best estimate of collision probability, and a similar estimate of collision probability that is based on prior assumptions about the likelihood of collision.
Rauch, Geraldine; Brannath, Werner; Brückner, Matthias; Kieser, Meinhard
2018-05-01
In many clinical trial applications, the endpoint of interest corresponds to a time-to-event endpoint. In this case, group differences are usually expressed by the hazard ratio. Group differences are commonly assessed by the logrank test, which is optimal under the proportional hazard assumption. However, there are many situations in which this assumption is violated. Especially in applications were a full population and several subgroups or a composite time-to-first-event endpoint and several components are considered, the proportional hazard assumption usually does not simultaneously hold true for all test problems under investigation. As an alternative effect measure, Kalbfleisch and Prentice proposed the so-called 'average hazard ratio'. The average hazard ratio is based on a flexible weighting function to modify the influence of time and has a meaningful interpretation even in the case of non-proportional hazards. Despite this favorable property, it is hardly ever used in practice, whereas the standard hazard ratio is commonly reported in clinical trials regardless of whether the proportional hazard assumption holds true or not. There exist two main approaches to construct corresponding estimators and tests for the average hazard ratio where the first relies on weighted Cox regression and the second on a simple plug-in estimator. The aim of this work is to give a systematic comparison of these two approaches and the standard logrank test for different time-toevent settings with proportional and nonproportional hazards and to illustrate the pros and cons in application. We conduct a systematic comparative study based on Monte-Carlo simulations and by a real clinical trial example. Our results suggest that the properties of the average hazard ratio depend on the underlying weighting function. The two approaches to construct estimators and related tests show very similar performance for adequately chosen weights. In general, the average hazard ratio defines a more valid effect measure than the standard hazard ratio under non-proportional hazards and the corresponding tests provide a power advantage over the common logrank test. As non-proportional hazards are often met in clinical practice and the average hazard ratio tests often outperform the common logrank test, this approach should be used more routinely in applications. Schattauer GmbH.
Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller
NASA Technical Reports Server (NTRS)
Schumann, L. F.; Clark, D. A.; Wood, J. R.
1986-01-01
A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.
Safety Testing of Ammonium Nitrate Based Mixtures
NASA Astrophysics Data System (ADS)
Phillips, Jason; Lappo, Karmen; Phelan, James; Peterson, Nathan; Gilbert, Don
2013-06-01
Ammonium nitrate (AN)/ammonium nitrate based explosives have a lengthy documented history of use by adversaries in acts of terror. While historical research has been conducted on AN-based explosive mixtures, it has primarily focused on detonation performance while varying the oxygen balance between the oxidizer and fuel components. Similarly, historical safety data on these materials is often lacking in pertinent details such as specific fuel type, particle size parameters, oxidizer form, etc. A variety of AN-based fuel-oxidizer mixtures were tested for small-scale sensitivity in preparation for large-scale testing. Current efforts focus on maintaining a zero oxygen-balance (a stoichiometric ratio for active chemical participants) while varying factors such as charge geometry, oxidizer form, particle size, and inert diluent ratios. Small-scale safety testing was conducted on various mixtures and fuels. It was found that ESD sensitivity is significantly affected by particle size, while this is less so for impact and friction. Thermal testing is in progress to evaluate hazards that may be experienced during large-scale testing.
Clemensson, Erik Karl Håkan; Clemensson, Laura Emily; Fabry, Benedikt; Riess, Olaf; Nguyen, Huu Phuc
2017-01-01
Huntington disease is an inherited neurodegenerative disorder characterized by motor, cognitive, psychiatric and metabolic symptoms. We recently published a study describing that the BACHD rat model of HD shows an obesity phenotype, which might affect their motivation to perform food-based behavioral tests. Further, we argued that using a food restriction protocol based on matching BACHD and wild type rats' food consumption rates might resolve these motivational differences. In the current study, we followed up on these ideas in a longitudinal study of the rats' performance in a progressive ratio test. We also investigated the phenotype of reduced food consumption rate, which is typically seen in food-restricted BACHD rats, in greater detail. In line with our previous study, the BACHD rats were less motivated to perform the progressive ratio test compared to their wild type littermates, although the phenotype was no longer present when the rats' food consumption rates had been matched. However, video analysis of food consumption tests suggested that the reduced consumption rate found in the BACHD rats was not entirely based on differences in hunger, but likely involved motoric impairments. Thus, restriction protocols based on food consumption rates are not appropriate when working with BACHD rats. As an alternative, we suggest that studies where BACHD rats are used should investigate how the readouts of interest are affected by motivational differences, and use appropriate control tests to avoid misleading results. In addition, we show that BACHD rats display distinct behavioral changes in their progressive ratio performance, which might be indicative of striatal dysfunction.
Effect of Solid to Liquid Ratio on Heavy Metal Removal by Geopolymer-Based Adsorbent
NASA Astrophysics Data System (ADS)
Ariffin, N.; Abdullah, M. M. A. B.; Arif Zainol, M. R. R. Mohd; Baltatu, M. S.; Jamaludin, L.
2018-06-01
Microstructure of three-dimensional aluminosilicate which similar to zeolite cause geopolymer based adsorbent accepted in the treatment of wastewater. This paper presents an investigation on the copper removal from the wastewater by varying the solid to liquid ratio in the fly ash, kaolin and sludge-based geopolymer adsorbent. The adsorption test was conducted to study the efficiency of the adsorbent and the copper concentration was examined by using Atomic Adsorption Spectrometry (AAS). The optimum solid to liquid ratio with the highest percentage removal were 1.0, 0.5 and 0.8 for fly ash-based geopolymer, kaolin-based geopolymer and sludge-based geopolymer adsorbent.
Prediction of hamstring injury in professional soccer players by isokinetic measurements
Dauty, Marc; Menu, Pierre; Fouasson-Chailloux, Alban; Ferréol, Sophie; Dubois, Charles
2016-01-01
Summary Objectives previous studies investigating the ability of isokinetic strength ratios to predict hamstring injuries in soccer players have reported conflicting results. Hypothesis to determine if isokinetic ratios are able to predict hamstring injury occurring during the season in professional soccer players. Study Design case-control study; Level of evidence: 3. Methods from 2001 to 2011, 350 isokinetic tests were performed in 136 professional soccer players at the beginning of the soccer season. Fifty-seven players suffered hamstring injury during the season that followed the isokinetic tests. These players were compared with the 79 uninjured players. The bilateral concentric ratio (hamstring-to-hamstring), ipsilateral concentric ratio (hamstring-to-quadriceps), and mixed ratio (eccentric/concentric hamstring-to-quadriceps) were studied. The predictive ability of each ratio was established based on the likelihood ratio and post-test probability. Results the mixed ratio (30 eccentric/240 concentric hamstring-to-quadriceps) <0.8, ipsilateral ratio (180 concentric hamstring-to-quadriceps) <0.47, and bilateral ratio (60 concentric hamstring-to-hamstring) <0.85 were the most predictive of hamstring injury. The ipsilateral ratio <0.47 allowed prediction of the severity of the hamstring injury, and was also influenced by the length of time since administration of the isokinetic tests. Conclusion isokinetic ratios are useful for predicting the likelihood of hamstring injury in professional soccer players during the competitive season. PMID:27331039
Hazard ratio estimation and inference in clinical trials with many tied event times.
Mehrotra, Devan V; Zhang, Yiwei
2018-06-13
The medical literature contains numerous examples of randomized clinical trials with time-to-event endpoints in which large numbers of events accrued over relatively short follow-up periods, resulting in many tied event times. A generally common feature across such examples was that the logrank test was used for hypothesis testing and the Cox proportional hazards model was used for hazard ratio estimation. We caution that this common practice is particularly risky in the setting of many tied event times for two reasons. First, the estimator of the hazard ratio can be severely biased if the Breslow tie-handling approximation for the Cox model (the default in SAS and Stata software) is used. Second, the 95% confidence interval for the hazard ratio can include one even when the corresponding logrank test p-value is less than 0.05. To help establish a better practice, with applicability for both superiority and noninferiority trials, we use theory and simulations to contrast Wald and score tests based on well-known tie-handling approximations for the Cox model. Our recommendation is to report the Wald test p-value and corresponding confidence interval based on the Efron approximation. The recommended test is essentially as powerful as the logrank test, the accompanying point and interval estimates of the hazard ratio have excellent statistical properties even in settings with many tied event times, inferential alignment between the p-value and confidence interval is guaranteed, and implementation is straightforward using commonly used software. Copyright © 2018 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Kim, W. Y.; Richards, P. G.
2017-12-01
At least four small seismic events were detected around the North Korean nuclear test site following the 3 September 2017 underground nuclear test. The magnitude of these shocks range from 2.6 to 3.5. Based on their proximity to the September 3 UNT, these shocks may be considered as aftershocks of the UNT. We assess the best method to classify these small events based on spectral amplitude ratios of regional P and S wave from the shocks. None of these shocks are classified as explosion-like based on P/S spectral amplitude ratios. We examine additional possible small seismic events around the North Korean test site by using seismic data from stations in southern Korea and northeastern China including IMS seismic arrays, GSN stations, and regional network stations in the region.
Christopher, David; Adams, Wallace P; Lee, Douglas S; Morgan, Beth; Pan, Ziqing; Singh, Gur Jai Pal; Tsong, Yi; Lyapustina, Svetlana
2007-01-19
The purpose of this article is to present the thought process, methods, and interim results of a PQRI Working Group, which was charged with evaluating the chi-square ratio test as a potential method for determining in vitro equivalence of aerodynamic particle size distribution (APSD) profiles obtained from cascade impactor measurements. Because this test was designed with the intention of being used as a tool in regulatory review of drug applications, the capability of the test to detect differences in APSD profiles correctly and consistently was evaluated in a systematic way across a designed space of possible profiles. To establish a "base line," properties of the test in the simplest case of pairs of identical profiles were studied. Next, the test's performance was studied with pairs of profiles, where some difference was simulated in a systematic way on a single deposition site using realistic product profiles. The results obtained in these studies, which are presented in detail here, suggest that the chi-square ratio test in itself is not sufficient to determine equivalence of particle size distributions. This article, therefore, introduces the proposal to combine the chi-square ratio test with a test for impactor-sized mass based on Population Bioequivalence and describes methods for evaluating discrimination capabilities of the combined test. The approaches and results described in this article elucidate some of the capabilities and limitations of the original chi-square ratio test and provide rationale for development of additional tests capable of comparing APSD profiles of pharmaceutical aerosols.
Fatigue crack propagation behavior of stainless steel welds
NASA Astrophysics Data System (ADS)
Kusko, Chad S.
The fatigue crack propagation behavior of austenitic and duplex stainless steel base and weld metals has been investigated using various fatigue crack growth test procedures, ferrite measurement techniques, light optical microscopy, stereomicroscopy, scanning electron microscopy, and optical profilometry. The compliance offset method has been incorporated to measure crack closure during testing in order to determine a stress ratio at which such closure is overcome. Based on this method, an empirically determined stress ratio of 0.60 has been shown to be very successful in overcoming crack closure for all da/dN for gas metal arc and laser welds. This empirically-determined stress ratio of 0.60 has been applied to testing of stainless steel base metal and weld metal to understand the influence of microstructure. Regarding the base metal investigation, for 316L and AL6XN base metals, grain size and grain plus twin size have been shown to influence resulting crack growth behavior. The cyclic plastic zone size model has been applied to accurately model crack growth behavior for austenitic stainless steels when the average grain plus twin size is considered. Additionally, the effect of the tortuous crack paths observed for the larger grain size base metals can be explained by a literature model for crack deflection. Constant Delta K testing has been used to characterize the crack growth behavior across various regions of the gas metal arc and laser welds at the empirically determined stress ratio of 0.60. Despite an extensive range of stainless steel weld metal FN and delta-ferrite morphologies, neither delta-ferrite morphology significantly influence the room temperature crack growth behavior. However, variations in weld metal da/dN can be explained by local surface roughness resulting from large columnar grains and tortuous crack paths in the weld metal.
Pei, Yanbo; Tian, Guo-Liang; Tang, Man-Lai
2014-11-10
Stratified data analysis is an important research topic in many biomedical studies and clinical trials. In this article, we develop five test statistics for testing the homogeneity of proportion ratios for stratified correlated bilateral binary data based on an equal correlation model assumption. Bootstrap procedures based on these test statistics are also considered. To evaluate the performance of these statistics and procedures, we conduct Monte Carlo simulations to study their empirical sizes and powers under various scenarios. Our results suggest that the procedure based on score statistic performs well generally and is highly recommended. When the sample size is large, procedures based on the commonly used weighted least square estimate and logarithmic transformation with Mantel-Haenszel estimate are recommended as they do not involve any computation of maximum likelihood estimates requiring iterative algorithms. We also derive approximate sample size formulas based on the recommended test procedures. Finally, we apply the proposed methods to analyze a multi-center randomized clinical trial for scleroderma patients. Copyright © 2014 John Wiley & Sons, Ltd.
White Matter Fiber-based Analysis of T1w/T2w Ratio Map.
Chen, Haiwei; Budin, Francois; Noel, Jean; Prieto, Juan Carlos; Gilmore, John; Rasmussen, Jerod; Wadhwa, Pathik D; Entringer, Sonja; Buss, Claudia; Styner, Martin
2017-02-01
To develop, test, evaluate and apply a novel tool for the white matter fiber-based analysis of T1w/T2w ratio maps quantifying myelin content. The cerebral white matter in the human brain develops from a mostly non-myelinated state to a nearly fully mature white matter myelination within the first few years of life. High resolution T1w/T2w ratio maps are believed to be effective in quantitatively estimating myelin content on a voxel-wise basis. We propose the use of a fiber-tract-based analysis of such T1w/T2w ratio data, as it allows us to separate fiber bundles that a common regional analysis imprecisely groups together, and to associate effects to specific tracts rather than large, broad regions. We developed an intuitive, open source tool to facilitate such fiber-based studies of T1w/T2w ratio maps. Via its Graphical User Interface (GUI) the tool is accessible to non-technical users. The framework uses calibrated T1w/T2w ratio maps and a prior fiber atlas as an input to generate profiles of T1w/T2w values. The resulting fiber profiles are used in a statistical analysis that performs along-tract functional statistical analysis. We applied this approach to a preliminary study of early brain development in neonates. We developed an open-source tool for the fiber based analysis of T1w/T2w ratio maps and tested it in a study of brain development.
White matter fiber-based analysis of T1w/T2w ratio map
NASA Astrophysics Data System (ADS)
Chen, Haiwei; Budin, Francois; Noel, Jean; Prieto, Juan Carlos; Gilmore, John; Rasmussen, Jerod; Wadhwa, Pathik D.; Entringer, Sonja; Buss, Claudia; Styner, Martin
2017-02-01
Purpose: To develop, test, evaluate and apply a novel tool for the white matter fiber-based analysis of T1w/T2w ratio maps quantifying myelin content. Background: The cerebral white matter in the human brain develops from a mostly non-myelinated state to a nearly fully mature white matter myelination within the first few years of life. High resolution T1w/T2w ratio maps are believed to be effective in quantitatively estimating myelin content on a voxel-wise basis. We propose the use of a fiber-tract-based analysis of such T1w/T2w ratio data, as it allows us to separate fiber bundles that a common regional analysis imprecisely groups together, and to associate effects to specific tracts rather than large, broad regions. Methods: We developed an intuitive, open source tool to facilitate such fiber-based studies of T1w/T2w ratio maps. Via its Graphical User Interface (GUI) the tool is accessible to non-technical users. The framework uses calibrated T1w/T2w ratio maps and a prior fiber atlas as an input to generate profiles of T1w/T2w values. The resulting fiber profiles are used in a statistical analysis that performs along-tract functional statistical analysis. We applied this approach to a preliminary study of early brain development in neonates. Results: We developed an open-source tool for the fiber based analysis of T1w/T2w ratio maps and tested it in a study of brain development.
Substantial advantage of a combined Bayesian and genotyping approach in testosterone doping tests.
Schulze, Jenny Jakobsson; Lundmark, Jonas; Garle, Mats; Ekström, Lena; Sottas, Pierre-Edouard; Rane, Anders
2009-03-01
Testosterone abuse is conventionally assessed by the urinary testosterone/epitestosterone (T/E) ratio, levels above 4.0 being considered suspicious. A deletion polymorphism in the gene coding for UGT2B17 is strongly associated with reduced testosterone glucuronide (TG) levels in urine. Many of the individuals devoid of the gene would not reach a T/E ratio of 4.0 after testosterone intake. Future test programs will most likely shift from population based- to individual-based T/E cut-off ratios using Bayesian inference. A longitudinal analysis is dependent on an individual's true negative baseline T/E ratio. The aim was to investigate whether it is possible to increase the sensitivity and specificity of the T/E test by addition of UGT2B17 genotype information in a Bayesian framework. A single intramuscular dose of 500mg testosterone enanthate was given to 55 healthy male volunteers with either two, one or no allele (ins/ins, ins/del or del/del) of the UGT2B17 gene. Urinary excretion of TG and the T/E ratio was measured during 15 days. The Bayesian analysis was conducted to calculate the individual T/E cut-off ratio. When adding the genotype information, the program returned lower individual cut-off ratios in all del/del subjects increasing the sensitivity of the test considerably. It will be difficult, if not impossible, to discriminate between a true negative baseline T/E value and a false negative one without knowledge of the UGT2B17 genotype. UGT2B17 genotype information is crucial, both to decide which initial cut-off ratio to use for an individual, and for increasing the sensitivity of the Bayesian analysis.
Prediction of in-depth gap heating ratios from wing glove model test data. [space shuttle orbiter
NASA Technical Reports Server (NTRS)
1977-01-01
In-depth gap heating ratios were predicted down RSI tile sidewalls based on temperature measurements obtained from the JSC arc-jet Wing Glove model tests in order to develop gap heating ratios which resulted in the best possible fit of test data and to produce a set of engineering verification heating ratios similar in shape to one another which could be used at various body points on the Orbiter during reentry. The Rockwell TPS Multidimensional heat conduction program was used to perform 3-D thermal analyses using a 3.0 in. thick section of a curved RSI tile with 283 nodal points. Correlation with test data shows that the predicted heating ratios were significantly higher down in the gap than the zero pressure values for T/C stacks 39 and 38 on the Wing Glove model. For stack 37 (in a low pressure region), the baseline heating ratio overpredicted the temperature data. This analysis, which showed that the heating ratios were a strong function of the product of pressure and pressure gradient, will be used to compare with recent Gap/Step and Ames Double Wedge test/analysis results in the effort to identify the Orbiter gap response to high delta P flight environment.
NASA Astrophysics Data System (ADS)
Kim, G.; Che, I. Y.
2017-12-01
We evaluated relationship among source parameters of underground nuclear tests in northern Korean Peninsula using regional seismic data. Dense global and regional seismic networks are incorporated to measure locations and origin times precisely. Location analyses show that distance among the locations is tiny on a regional scale. The tiny location-differences validate a linear model assumption. We estimated source spectral ratios by excluding path effects based spectral ratios of the observed seismograms. We estimated empirical relationship among depth of burials and yields based on theoretical source models.
Schackman, Bruce R; Metsch, Lisa R; Colfax, Grant N; Leff, Jared A; Wong, Angela; Scott, Callie A; Feaster, Daniel J; Gooden, Lauren; Matheson, Tim; Haynes, Louise F; Paltiel, A David; Walensky, Rochelle P
2013-02-01
The President's National HIV/AIDS Strategy calls for coupling HIV screening and prevention services with substance abuse treatment programs. Fewer than half of US community-based substance abuse treatment programs make HIV testing available on-site or through referral. We measured the cost-effectiveness of three HIV testing strategies evaluated in a randomized trial conducted in 12 community-based substance abuse treatment programs in 2009: off-site testing referral, on-site rapid testing with information only, on-site rapid testing with risk-reduction counseling. Data from the trial included patient demographics, prior testing history, test acceptance and receipt of results, undiagnosed HIV prevalence (0.4%) and program costs. The Cost-Effectiveness of Preventing AIDS Complications (CEPAC) computer simulation model was used to project life expectancy, lifetime costs, and quality-adjusted life years (QALYs) for HIV-infected individuals. Incremental cost-effectiveness ratios (2009 US $/QALY) were calculated after adding costs of testing HIV-uninfected individuals; costs and QALYs were discounted at 3% annually. Referral for off-site testing is less efficient (dominated) compared to offering on-site testing with information only. The cost-effectiveness ratio for on-site testing with information is $60,300/QALY in the base case, or $76,300/QALY with 0.1% undiagnosed HIV prevalence. HIV risk-reduction counseling costs $36 per person more without additional benefit. A strategy of on-site rapid HIV testing offer with information only in substance abuse treatment programs increases life expectancy at a cost-effectiveness ratio <$100,000/QALY. Policymakers and substance abuse treatment leaders should seek funding to implement on-site rapid HIV testing in substance abuse treatment programs for those not recently tested. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Schackman, Bruce R.; Metsch, Lisa R.; Colfax, Grant N.; Leff, Jared A.; Wong, Angela; Scott, Callie A.; Feaster, Daniel J.; Gooden, Lauren; Matheson, Tim; Haynes, Louise F.; Paltiel, A. David; Walensky, Rochelle P.
2012-01-01
BACKGROUND The President’s National HIV/AIDS Strategy calls for coupling HIV screening and prevention services with substance abuse treatment programs. Fewer than half of US community-based substance abuse treatment programs make HIV testing available on-site or through referral. METHODS We measured the cost-effectiveness of three HIV testing strategies evaluated in a randomized trial conducted in 12 community-based substance abuse treatment programs in 2009: off-site testing referral, on-site rapid testing with information only, on-site rapid testing with risk reduction counseling. Data from the trial included patient demographics, prior testing history, test acceptance and receipt of results, undiagnosed HIV prevalence (0.4%) and program costs. The Cost Effectiveness of Preventing AIDS Complications (CEPAC) computer simulation model was used to project life expectancy, lifetime costs, and quality-adjusted life years (QALYs) for HIV-infected individuals. Incremental cost-effectiveness ratios (2009 US $/QALY) were calculated after adding costs of testing HIV-uninfected individuals; costs and QALYs were discounted at 3% annually. RESULTS Referral for off-site testing is less efficient (dominated) compared to offering on-site testing with information only. The cost-effectiveness ratio for on-site testing with information is $60,300/QALY in the base case, or $76,300/QALY with 0.1% undiagnosed HIV prevalence. HIV risk-reduction counseling costs $36 per person more without additional benefit. CONCLUSIONS A strategy of on-site rapid HIV testing offer with information only in substance abuse treatment programs increases life expectancy at a cost-effectiveness ratio <$100,000/QALY. Policymakers and substance abuse treatment leaders should seek funding to implement on-site rapid HIV testing in substance abuse treatment programs for those not recently tested. PMID:22971593
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wrenn, M.E.; Singh, N.P.; Paschoa, A.S.
1992-11-01
Residual radioactivity consisting of 239 Pu were measured by radiochemistry and alpha spectrometry in samples of bone and soft tissues from 100 autopsies or surgeries from northern and southwestern Utah and from control areas in Colorado and Pennsylvania. Based upon the isotopic ratio 240 Pu/239 Pu contamination was attributable to atmospheric weapons tests at the Nevada Test Site (NTS). In addition, 110 thyroid tissue samples obtained from tissue blocks made at autopsy of veterans dying at the VA hospital in Salt Lake City in the 1940's and 1950's were measured for 129 I (half life 16 million year) and 127more » I (stable) by neutron activation. The results were analyzed by year of death, by periods before and during atmospheric nuclear weapons testing at the NTS and by origin of usual residence. A model was developed to relate thyroid dose from 131 I to the measured 124/127 I ratios, and thyroid dose estimates were made based upon the measured ratios.« less
Clemensson, Laura Emily; Fabry, Benedikt; Riess, Olaf; Nguyen, Huu Phuc
2017-01-01
Huntington disease is an inherited neurodegenerative disorder characterized by motor, cognitive, psychiatric and metabolic symptoms. We recently published a study describing that the BACHD rat model of HD shows an obesity phenotype, which might affect their motivation to perform food-based behavioral tests. Further, we argued that using a food restriction protocol based on matching BACHD and wild type rats’ food consumption rates might resolve these motivational differences. In the current study, we followed up on these ideas in a longitudinal study of the rats’ performance in a progressive ratio test. We also investigated the phenotype of reduced food consumption rate, which is typically seen in food-restricted BACHD rats, in greater detail. In line with our previous study, the BACHD rats were less motivated to perform the progressive ratio test compared to their wild type littermates, although the phenotype was no longer present when the rats’ food consumption rates had been matched. However, video analysis of food consumption tests suggested that the reduced consumption rate found in the BACHD rats was not entirely based on differences in hunger, but likely involved motoric impairments. Thus, restriction protocols based on food consumption rates are not appropriate when working with BACHD rats. As an alternative, we suggest that studies where BACHD rats are used should investigate how the readouts of interest are affected by motivational differences, and use appropriate control tests to avoid misleading results. In addition, we show that BACHD rats display distinct behavioral changes in their progressive ratio performance, which might be indicative of striatal dysfunction. PMID:28273120
Measures of accuracy and performance of diagnostic tests.
Drobatz, Kenneth J
2009-05-01
Diagnostic tests are integral to the practice of veterinary cardiology, any other specialty, and general veterinary medicine. Developing and understanding diagnostic tests is one of the cornerstones of clinical research. This manuscript describes the diagnostic test properties including sensitivity, specificity, predictive value, likelihood ratio, receiver operating characteristic curve. Review of practical book chapters and standard statistics manuscripts. Diagnostics such as sensitivity, specificity, predictive value, likelihood ratio, and receiver operating characteristic curve are described and illustrated. Basic understanding of how diagnostic tests are developed and interpreted is essential in reviewing clinical scientific papers and understanding evidence based medicine.
Multiratio fusion change detection with adaptive thresholding
NASA Astrophysics Data System (ADS)
Hytla, Patrick C.; Balster, Eric J.; Vasquez, Juan R.; Neuroth, Robert M.
2017-04-01
A ratio-based change detection method known as multiratio fusion (MRF) is proposed and tested. The MRF framework builds on other change detection components proposed in this work: dual ratio (DR) and multiratio (MR). The DR method involves two ratios coupled with adaptive thresholds to maximize detected changes and minimize false alarms. The use of two ratios is shown to outperform the single ratio case when the means of the image pairs are not equal. MR change detection builds on the DR method by including negative imagery to produce four total ratios with adaptive thresholds. Inclusion of negative imagery is shown to improve detection sensitivity and to boost detection performance in certain target and background cases. MRF further expands this concept by fusing together the ratio outputs using a routine in which detections must be verified by two or more ratios to be classified as a true changed pixel. The proposed method is tested with synthetically generated test imagery and real datasets with results compared to other methods found in the literature. DR is shown to significantly outperform the standard single ratio method. MRF produces excellent change detection results that exhibit up to a 22% performance improvement over other methods from the literature at low false-alarm rates.
The Effect of Cooling Passage Aspect Ratio on Curvature Heat Transfer Enhancement
NASA Technical Reports Server (NTRS)
Meyer, Michael L.
1997-01-01
A series of electrically heated tube experiments was performed to investigate the effect of high aspect ratio on curvature heat transfer enhancement in uniformly heated rectangular cooling passages. Three hardware geometries were tested: a baseline straight aspect ratio 10 tube, an aspect ratio 1 (square) tube with a 45 deg. curve, and an aspect ratio 10 tube with a 45 deg. curve. Gaseous nitrogen with the following properties was used as the coolant: ambient inlet temperature, pressures to 8.3 MPa, wall-to-bulk temperature ratios less than two, and Reynolds numbers based on hydraulic diameter ranging from 250,000 to 1,600,000. The measured curvature enhancement factors were compared to values predicted by three previously published models which had been developed for low aspect ratio tubes. The models were shown to be valid for the high aspect ratio tube as well the low aspect ratio tube, indicating that aspect ratio had little impact on the curvature heat transfer enhancement in these tests.
Distributed Immune Systems for Wireless Network Information Assurance
2010-04-26
ratio test (SPRT), where the goal is to optimize a hypothesis testing problem given a trade-off between the probability of errors and the...using cumulative sum (CUSUM) and Girshik-Rubin-Shiryaev (GRSh) statistics. In sequential versions of the problem the sequential probability ratio ...the more complicated problems, in particular those where no clear mean can be established. We developed algorithms based on the sequential probability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farooqi, Rahmat Ullah; Hrma, Pavel
2016-06-01
We have investigated the effect of A1/B ratio on the Product Consistency Test (PCT) response. In an aluminoborosilicate soda-lime glass based on a modified International Simple Glass, ISG-3, the A1/B ratio varied from 0 to 0.55 (in mole fractions). In agreement with various models of the PCT response as a function of glass composition, we observed a monotonic increase of B and Na releases with decreasing A1/B mole ratio, but only when the ratio was higher than 0.05. Below this value (A1/B < 0.05), we observed a sharp decrease that we attribute to B in tetrahedral coordination.
Modeling of UH-60A Hub Accelerations with Neural Networks
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi
2002-01-01
Neural network relationships between the full-scale, flight test hub accelerations and the corresponding three N/rev pilot floor vibration components (vertical, lateral, and longitudinal) are studied. The present quantitative effort on the UH-60A Black Hawk hub accelerations considers the lateral and longitudinal vibrations. An earlier study had considered the vertical vibration. The NASA/Army UH-60A Airloads Program flight test database is used. A physics based "maneuver-effect-factor (MEF)", derived using the roll-angle and the pitch-rate, is used. Fundamentally, the lateral vibration data show high vibration levels (up to 0.3 g's) at low airspeeds (for example, during landing flares) and at high airspeeds (for example, during turns). The results show that the advance ratio and the gross weight together can predict the vertical and the longitudinal vibration. However, the advance ratio and the gross weight together cannot predict the lateral vibration. The hub accelerations and the advance ratio can be used to satisfactorily predict the vertical, lateral, and longitudinal vibration. The present study shows that neural network based representations of all three UH-60A pilot floor vibration components (vertical, lateral, and longitudinal) can be obtained using the hub accelerations along with the gross weight and the advance ratio. The hub accelerations are clearly a factor in determining the pilot vibration. The present conclusions potentially allow for the identification of neural network relationships between the experimental hub accelerations obtained from wind tunnel testing and the experimental pilot vibration data obtained from flight testing. A successful establishment of the above neural network based link between the wind tunnel hub accelerations and the flight test vibration data can increase the value of wind tunnel testing.
NASA Astrophysics Data System (ADS)
Chen, Xi; Zhong, Jiaqi; Song, Hongwei; Zhu, Lei; Wang, Jin; Zhan, Mingsheng
2014-08-01
Vibrational noise is one of the most important noises that limits the performance of the nonisotopes atom-interferometers (AIs) -based weak-equivalence-principle (WEP) -test experiment. By analyzing the vibration-induced phases, we find that, although the induced phases are not completely common, their ratio is always a constant at every experimental data point, which is not fully utilized in the traditional elliptic curve-fitting method. From this point, we propose a strategy that can greatly suppress the vibration-induced phase noise by stabilizing the Raman laser frequencies at high precision and controlling the scanning-phase ratio. The noise rejection ratio can be as high as 1015 with arbitrary dual-species AIs. Our method provides a Lissajous curve, and the shape of the curve indicates the breakdown of the weak-equivalence-principle signal. Then we manage to derive an estimator for the differential phase of the Lissajous curve. This strategy could be helpful in extending the candidates of atomic species for high-precision AIs-based WEP-test experiments.
LASER BIOLOGY AND MEDICINE: Laser analysis of the 13C/12C isotope ratio in CO2 in exhaled air
NASA Astrophysics Data System (ADS)
Stepanov, E. V.
2002-11-01
Tunable diode lasers (TDLs) are applied to the diagnostics of gastroenterological diseases using respiratory tests and preparations enriched with the stable 13C isotope. This method of the analysis of the 13C/12C isotope ratio in CO2 in exhaled air is based on the selective measurement of the resonance absorption at the vibrational — rotational structure of 12CO2 and 13CO2. The CO2 transmission spectra in the region of 4.35 μm were measured with a PbEuSe double-heterostructure TDL. The accuracy of carbon isotope ratio measurements in CO2 of exhaled air performed with the TDL was ~0.5%. The data of clinical tests of the developed laser-based analyser are presented.
Zhou, Lan; Yang, Jin-Bo; Liu, Dan; Liu, Zhan; Chen, Ying; Gao, Bo
2008-06-01
To analyze the possible damage to the remaining tooth and composite restorations when various mixing ratios of bases were used. Testing elastic modulus and poission's ratio of glass-ionomer Vitrebond and self-cured calcium hydroxide Dycal with mixing ratios of 1:1, 3:4, 4:3. Micro-CT was used to scan the first mandibular molar, and the three-dimensional finite element model of the first permanent mandibular molar with class I cavity was established. Analyzing the stress of tooth structure, composite and base cement under physical load when different mixing ratios of base cement were used. The elastic modulus of base cement in various mixing ratios was different, which had the statistic significance. The magnitude and location of stress in restored tooth made no differences when the mixing ratios of Vitrebond and Dycal were changed. The peak stress and spreading area in the model with Dycal was more than that with Vitrebond. Changing the best mixing ratio of base cement can partially influence the mechanistic character, but make no differences on the magnitude and location of stress in restored tooth. During the treatment of deep caries, the base cement of the elastic modulus which is proximal to the dentin and restoration should be chosen to avoid the fracture of tooth or restoration.
Tree-Based Global Model Tests for Polytomous Rasch Models
ERIC Educational Resources Information Center
Komboz, Basil; Strobl, Carolin; Zeileis, Achim
2018-01-01
Psychometric measurement models are only valid if measurement invariance holds between test takers of different groups. Global model tests, such as the well-established likelihood ratio (LR) test, are sensitive to violations of measurement invariance, such as differential item functioning and differential step functioning. However, these…
Feasibility study of a large-scale tuned mass damper with eddy current damping mechanism
NASA Astrophysics Data System (ADS)
Wang, Zhihao; Chen, Zhengqing; Wang, Jianhui
2012-09-01
Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-known disadvantages, such as oil leakage and difficult adjustment of damping ratio for an operating TMD. Alternatively, eddy current damping (ECD) that does not require any contact with the main structure is a potential solution. This paper discusses the design, analysis, manufacture and testing of a large-scale horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one large-scale horizontal TMD using ECD is constructed, and finally performance tests of the TMD are conducted. The test results show that the proposed TMD has a very low intrinsic damping ratio, while the damping ratio due to ECD is the dominant damping source, which can be as large as 15% in a proper configuration. In addition, the damping ratios estimated with the theoretical model are roughly consistent with those identified from the test results, and the source of this error is investigated. Moreover, it is demonstrated that the damping ratio in the proposed TMD can be easily adjusted by varying the air gap between permanent magnets and conductive plates. In view of practical applications, possible improvements and feasibility considerations for the proposed TMD are then discussed. It is confirmed that the proposed TMD with ECD is reliable and feasible for use in structural vibration control.
Ignition and Performance Tests of Rocket-Based Combined Cycle Propulsion System
NASA Technical Reports Server (NTRS)
Anderson, William E.
2005-01-01
The ground testing of a Rocket Based Combined Cycle engine implementing the Simultaneous Mixing and Combustion scheme was performed at the direct-connect facility of Purdue University's High Pressure Laboratory. The fuel-rich exhaust of a JP-8/H2O2 thruster was mixed with compressed, metered air in a constant area, axisymmetric duct. The thruster was similar in design and function to that which will be used in the flight test series of Dryden's Ducted-Rocket Experiment. The determination of duct ignition limits was made based on the variation of secondary air flow rates and primary thruster equivalence ratios. Thrust augmentation and improvements in specific impulse were studied along with the pressure and temperature profiles of the duct to study mixing lengths and thermal choking. The occurrence of ignition was favored by lower rocket equivalence ratios. However, among ignition cases, better thrust and specific impulse performance were seen with higher equivalence ratios owing to the increased fuel available for combustion. Thrust and specific impulse improvements by factors of 1.2 to 1.7 were seen. The static pressure and temperature profiles allowed regions of mixing and heat addition to be identified. The mixing lengths were found to be shorter at lower rocket equivalence ratios. Total pressure measurements allowed plume-based calculation of thrust, which agreed with load-cell measured values to within 6.5-8.0%. The corresponding Mach Number profile indicated the flow was not thermally choked for the highest duct static pressure case.
Jiang, Ying-He; Liu, Pei-Ju; Wang, Lei; Tian, Zhong-Kai; Liu, Xiao-Ying
2014-04-01
By building the mass balance of nitrogen in A2/O process, the nitrogen model which raised some strategies on how to control sludge return ratio and mixed liquid return ratio to make the effluent nitrogen achieve the national standard A under different influent total nitrogen (TN) , was set up. And the presumed parameters were verified by the pilot test of the Wuhan's Longwangzui WWTP. The result showed that when the temperature and the TN were over 15 degrees C and below 30 mg x L(-1) respectively, the mixed liquid return ratio was 0. When the temperature was between 10 degrees C and 15 degrees C and TN was over 30 mg x L(-1), higher MLSS and DO elevated N removal. When the temperature was far below 10 degrees C, the mixed liquid return ratio was also at a higher level. Based on the Wuhan's Longwangzui WWTP influent water quality, measures of adjusting the return ratio were well adapted to obtain acceptable nitrogen effluent.
Yang, Bo Ra; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young
2018-04-01
To evaluate qualitative and semiquantitative elastography for the diagnosis of intermediate suspicious thyroid nodules based on the 2015 American Thyroid Association (ATA) guidelines. Through a retrospective search of our institutional database, 746 solid thyroid nodules found on grayscale ultrasonography, strain elastography, and ultrasound-guided fine-needle aspiration between June and November 2009 were collected. Among them, 80 nodules from 80 patients with an intermediate suspicion of malignancy based on the 2015 ATA guidelines that were 10 mm or larger were recruited as the final study nodules. Elastographic findings were categorized according to the criteria of Rago et al (J Clin Endocrinol Metab 2007; 92:2917-2922) and Asteria et al (Thyroid 2008; 18:523-531), and strain ratio values were calculated and recorded. The independent 2-sample t test and χ 2 test (or Fisher exact test) were used to evaluate differences in clinical parameters between benign and malignant thyroid nodules. All variables were compared by univariate and multivariate logistic regression analyses, and odds ratios with 95% confidence intervals were calculated. Of the 80 nodules, 6 (7.5%) were malignant, and 74 (92.5%) were benign. No significant differences were observed in age, sex, nodule size, elasticity score, and strain ratio between benign and malignant nodules. No variables significantly predicted thyroid malignancy on the univariate analysis. On the multivariate logistic regression analysis, there were no independent variables associated with thyroid malignancy, including the elasticity score and strain ratio (all P > .05). Elastographic analysis using the elasticity score and strain ratio has limited ability to characterize the benignity or malignancy of thyroid nodules with an intermediate suspicion of malignancy based on the 2015 ATA guidelines. © 2017 by the American Institute of Ultrasound in Medicine.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; Johnston, William M., Jr.
2014-01-01
Mixed mode I-mode II interlaminar tests were conducted on IM7/8552 tape laminates using the mixed-mode bending test. Three mixed mode ratios, G(sub II)/G(sub T) = 0.2, 0.5, and 0.8, were considered. Tests were performed at all three mixed-mode ratios under quasi-static and cyclic loading conditions, where the former static tests were used to determine initial loading levels for the latter fatigue tests. Fatigue tests at each mixed-mode ratio were performed at four loading levels, Gmax, equal to 0.5G(sub c), 0.4G(sub c), 0.3G(sub c), and 0.2G(sub c), where G(sub c) is the interlaminar fracture toughness of the corresponding mixed-mode ratio at which a test was performed. All fatigue tests were performed using constant-amplitude load control and delamination growth was automatically documented using compliance solutions obtained from the corresponding quasi-static tests. Static fracture toughness data yielded a mixed-mode delamination criterion that exhibited monotonic increase in Gc with mixed-mode ratio, G(sub II)/G(sub T). Fatigue delamination onset parameters varied monotonically with G(sub II)/G(sub T), which was expected based on the fracture toughness data. Analysis of non-normalized data yielded a monotonic change in Paris law exponent with mode ratio. This was not the case when normalized data were analyzed. Fatigue data normalized by the static R-curve were most affected in specimens tested at G(sub II)/G(sub T)=0.2 (this process has little influence on the other data). In this case, the normalized data yielded a higher delamination growth rate compared to the raw data for a given loading level. Overall, fiber bridging appeared to be the dominant mechanism, affecting delamination growth rates in specimens tested at different load levels and differing mixed-mode ratios.
Full scale hover test of a 25 foot tilt rotor
NASA Technical Reports Server (NTRS)
Helf, S.; Broman, E.; Gatchel, S.; Charles, B.
1973-01-01
The tilt rotor underwent a hover performance test on the Aero Propulsion Laboratory whirl stand at Wright-Patterson Air Force Base. The maximum thrust over density ratio measured at the design tip speed of 740 feet per second was 10,016 pounds. This occurred when the power over density ratio was 1721 horsepower. At the hover overspeed rpm, the thrust and power, over density ratio, were 11,008 pounds and 1866 horsepower. During the test, the maximum measured thrust coefficient was 0.177, and the rotor figure of merit exceeded 0.81. Measured lifting efficiency was 8.35 pounds per horsepower at the thrust a 13,000-pound aircraft would require for hover at sea level on a standard day. No effect of compressibility on performance is discernible in the test results (the range of tip Mach numbers tested was 0.55 to 0.71).
NASA Technical Reports Server (NTRS)
Meyer, Carl L.
1946-01-01
Tests show that at inlet-air temperatures of 250 deg F and 100 deg F the knock-limited performance of the base fuel of blends, leaded with 4 ml TEL per gallon and containing 20 percent spiropentane, was reduced at fuel/air ratios below 0.085. The 20 percent methylenecyclobutane reduced the knock-limited power of the base fuel at fuel/air ratios below 0.112. Di-tert-butyl ether, methyl-tert-butyl ether, and triptane increased the knock-limited power of the base fuel at all fuel/air ratios and at both temperatures.
NASA Technical Reports Server (NTRS)
Allen, J. B.; Oliver, W. R.; Spacht, L. A.
1982-01-01
The wind tunnel testing of an advanced technology high lift system for a wide body and a narrow body transport incorporating high aspect ratio supercritical wings is described. This testing has added to the very limited low speed high Reynolds number data base for this class or aircraft. The experimental results include the effects on low speed aerodynamic characteristics of various leading and trailing edge devices, nacelles and pylons, ailerons, and spoilers, and the effects of Mach and Reynolds numbers.
Kozowyk, P R B; Langejans, G H J; Poulis, J A
2016-01-01
The production of compound adhesives using disparate ingredients is seen as some of the best evidence of advanced cognition outside of the use of symbolism. Previous field and laboratory testing of adhesives has shown the complexities involved in creating an effective Middle Stone Age glue using Acacia gum. However, it is currently unclear how efficient different adhesive recipes are, how much specific ingredients influence their performance, and how difficult it may have been for those ingredients to be combined to maximum effect. We conducted a series of laboratory-based lap shear and impact tests, following modern adhesion testing standards, to determine the efficacy of compound adhesives, with particular regard to the ingredient ratios. We tested rosin (colophony) and gum adhesives, containing additives of beeswax and ochre in varying ratios. During both lap shear and impact tests compound rosin adhesives performed better than single component rosin adhesives, and pure acacia gum was the strongest. The large difference in performance between each base adhesive and the significant changes in performance that occur due to relatively small changes in ingredient ratios lend further support to the notion that high levels of skill and knowledge were required to consistently produce the most effective adhesives.
2016-01-01
The production of compound adhesives using disparate ingredients is seen as some of the best evidence of advanced cognition outside of the use of symbolism. Previous field and laboratory testing of adhesives has shown the complexities involved in creating an effective Middle Stone Age glue using Acacia gum. However, it is currently unclear how efficient different adhesive recipes are, how much specific ingredients influence their performance, and how difficult it may have been for those ingredients to be combined to maximum effect. We conducted a series of laboratory-based lap shear and impact tests, following modern adhesion testing standards, to determine the efficacy of compound adhesives, with particular regard to the ingredient ratios. We tested rosin (colophony) and gum adhesives, containing additives of beeswax and ochre in varying ratios. During both lap shear and impact tests compound rosin adhesives performed better than single component rosin adhesives, and pure acacia gum was the strongest. The large difference in performance between each base adhesive and the significant changes in performance that occur due to relatively small changes in ingredient ratios lend further support to the notion that high levels of skill and knowledge were required to consistently produce the most effective adhesives. PMID:26983080
McBride, Colleen M; Alford, Sharon Hensley; Reid, Robert J; Larson, Eric B; Baxevanis, Andreas D; Brody, Lawrence C
2009-08-01
To evaluate what psychological and behavioral factors predict who is likely to seek SNP-based genetic tests for multiple common health conditions where feedback can be used to motivate primary prevention. Adults aged 25-40 years who were enrolled in a large managed care organization were surveyed. Those eligible could log on to a secure study Web site to review information about the risks and benefits of a SNP-based genetic test and request free testing. Two primary outcomes are addressed: accessing the Web (yes or no) and deciding to be tested (completed a blood draw at the clinic) Those considering genetic susceptibility testing did not hold genetically deterministic beliefs (0.42 on scale of 0 [behavior] to 1 [genetic]) but believed genetic information to be valuable and were confident they could understand such information. Individuals who believed it important to learn about genetics (odds ratio = 1.28), were confident they could understand genetics (odds ratio = 1.26), and reported the most health habits to change (odds ratio = 1.39) were most likely to get tested. Individuals who present to health care providers with online genetics information may be among the most motivated to take steps toward healthier lifestyles. These motives might be leveraged by health care providers to promote positive health outcomes.
Cost-Effectiveness of Opt-Out Chlamydia Testing for High-Risk Young Women in the U.S.
Owusu-Edusei, Kwame; Hoover, Karen W; Gift, Thomas L
2016-08-01
In spite of chlamydia screening recommendations, U.S. testing coverage continues to be low. This study explored the cost-effectiveness of a patient-directed, universal, opportunistic Opt-Out Testing strategy (based on insurance coverage, healthcare utilization, and test acceptance probabilities) for all women aged 15-24 years compared with current Risk-Based Screening (30% coverage) from a societal perspective. Based on insurance coverage (80%); healthcare utilization (83%); and test acceptance (75%), the proposed Opt-Out Testing strategy would have an expected annual testing coverage of approximately 50% for sexually active women aged 15-24 years. A basic compartmental heterosexual transmission model was developed to account for population-level transmission dynamics. Two groups were assumed based on self-reported sexual activity. All model parameters were obtained from the literature. Costs and benefits were tracked over a 50-year period. The relative sensitivity of the estimated incremental cost-effectiveness ratios to the variables/parameters was determined. This study was conducted in 2014-2015. Based on the model, the Opt-Out Testing strategy decreased the overall chlamydia prevalence by >55% (2.7% to 1.2%). The Opt-Out Testing strategy was cost saving compared with the current Risk-Based Screening strategy. The estimated incremental cost-effectiveness ratio was most sensitive to the female pre-opt out prevalence, followed by the probability of female sequelae and discount rate. The proposed Opt-Out Testing strategy was cost saving, improving health outcomes at a lower net cost than current testing. However, testing gaps would remain because many women might not have health insurance coverage, or not utilize health care. Published by Elsevier Inc.
Forces on a segregating particle
NASA Astrophysics Data System (ADS)
Lueptow, Richard M.; Shankar, Adithya; Fry, Alexander M.; Ottino, Julio M.; Umbanhowar, Paul B.
2017-11-01
Size segregation in flowing granular materials is not well understood at the particle level. In this study, we perform a series of 3D Discrete Element Method (DEM) simulations to measure the segregation force on a single spherical test particle tethered to a spring in the vertical direction in a shearing bed of particles with gravity acting perpendicular to the shear. The test particle is the same size or larger than the bed particles. At equilibrium, the downward spring force and test particle weight are offset by the upward buoyancy-like force and a size ratio dependent force. We find that the buoyancy-like force depends on the bed particle density and the Voronoi volume occupied by the test particle. By changing the density of the test particle with the particle size ratio such that the buoyancy force matches the test particle weight, we show that the upward size segregation force is a quadratic function of the particle size ratio. Based on this, we report an expression for the net force on a single particle as the sum of a size ratio dependent force, a buoyancy-like force, and the weight of the particle. Supported by NSF Grant CBET-1511450 and the Procter and Gamble Company.
A new diagnostic approach for bilious pleural effusion.
Saraya, Takeshi; Light, Richard W; Sakuma, Sho; Nakamoto, Yasuo; Wada, Shoko; Ishida, Manabu; Inui, Toshiya; Koide, Takashi; Ishii, Haruyuki; Takizawa, Hajime
2016-09-01
Bilious pleural effusion is an extremely rare condition associated with liver diseases, subphrenic or subhepatic abscess formation, biliary peritonitis, and invasive procedures (i.e., percutaneous biliary drainage or liver biopsy). The current diagnostic test is based on the measurement of the ratio of pleural total bilirubin to serum total bilirubin, which is greater than 1 in patients with bilious pleural effusion. Given the low incidence of bilious pleural effusion, the precise diagnostic yield of this ratio based test has not been evaluated. We retrospectively reviewed the medical records of our institution and searched the PubMed database for reports of bilious pleural effusion. We identified a total of 12 cases of bilious pleural effusion (9 from 8 Pubmed reports and 3 from our institutional records). The factors causing this condition were broadly classified into three categories based on the pathophysiology: 1) liver diseases (echinococcosis, tuberculosis and amebiasis); 2) subhepatic/subphrenic abscess or biliary peritonitis, with or without biliary tract obstruction; and 3) iatrogenic disease after percutaneous biliary drainage and/or liver biopsy. The sensitivity of detection was 76.9% when the ratio of pleural total bilirubin to serum total bilirubin was greater than 1. The sensitivity increased to 100% when a combination test including pleural glycoholic acid was adopted. This study demonstrates the high diagnostic yield for bilious pleural effusion using a combination of two test criteria; a ratio of pleural total bilirubin to serum total bilirubin greater than 1 and the presence of pleural glycoholic acid. Copyright © 2016 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
Cylindrical diffuser performance using a truncated plug nozzle
NASA Technical Reports Server (NTRS)
Galanga, F. L.; Mueller, T. J.
1976-01-01
Cylindrical diffuser performance for a truncated plug nozzle without external flow was tested in a blowdown wind tunnel. The nozzle was designed for an exit Mach number of 1.9 and the plug was conical in shape from the throat and converged to the axis of symmetry at an angle of 10 degrees. The diffuser section was fashioned into two 13.97 cm lengths to facilitate boring of the duct diameter and to allow for testing of two different duct lengths. A slotted hypotube was installed in the base of the diffuser to measure pressure distribution down the centerline of the diffuser. The data obtained included: the typical centerline and sidewall pressure ratio variation along the diffuser, cell pressure ratio vs overall pressure ratio for long and short diffusers and a comparison of minimum experimental cell pressure ratio vs area ratio.
Initial economic and operations data base for DSS 13 automation test
NASA Technical Reports Server (NTRS)
Remer, D. S.; Lorden, G.
1979-01-01
A summary is given of the data base collected for nine weeks of Deep Space Station II. Life cycle cost parameters on efficiency and productivity ratios, costs, and telemetry were calculated from this data base.
Miller, Ted R; Zaloshnja, Eduard; Spicer, Rebecca S
2007-05-01
Few studies have evaluated the impact of workplace substance abuse prevention programs on occupational injury, despite this being a justification for these programs. This paper estimates the effectiveness and benefit-cost ratio of a peer-based substance abuse prevention program at a U.S. transportation company, implemented in phases from 1988 to 1990. The program focuses on changing workplace attitudes toward on-the-job substance use in addition to training workers to recognize and intervene with coworkers who have a problem. The program was strengthened by federally mandated random drug and alcohol testing (implemented, respectively, in 1990 and 1994). With time-series analysis, we analyzed the association of monthly injury rates and costs with phased program implementation, controlling for industry injury trend. The combination of the peer-based program and testing was associated with an approximate one-third reduction in injury rate, avoiding an estimated $48 million in employer costs in 1999. That year, the peer-based program cost the company $35 and testing cost another $35 per employee. The program avoided an estimated $1850 in employer injury costs per employee in 1999, corresponding to a benefit-cost ratio of 26:1. The findings suggest that peer-based programs buttressed by random testing can be cost-effective in the workplace.
Koeck, A; Miglior, F; Jamrozik, J; Kelton, D F; Schenkel, F S
2013-07-01
The aim of this study was to investigate the genetic associations of ketosis and displaced abomasum with milk production traits in early first lactation of Canadian Holsteins. Health data recorded by producers were available from the national dairy cattle health system in Canada. Test-day records of milk, fat, and protein yields were obtained from the routine milk recoding scheme. Ketosis and displaced abomasum were defined as binary traits (0 = healthy; 1 = sick) based on whether or not the cow had at least 1 case of the respective disease in the period from calving to 100 d after calving. Mean frequencies of ketosis and displaced abomasum were 4.1 and 2.7%, respectively. The following milk production traits were considered: milk yield, fat percentage (Fat%), protein percentage (Prot%), fat-to-protein (F:P) ratio, and F:P ratio >1.5. The trait F:P ratio >1.5 was scored as 1 or 0, based on whether or not the cow had an F:P ratio >1.5. For milk production traits, the first (5-30 d in milk) and the second (31-60 d in milk) test days were considered. Data were analyzed using bivariate linear animal models. Average heritabilities of 0.02 and 0.04 were obtained for ketosis and displaced abomasum, respectively. For milk production traits, the lowest heritabilities were obtained for F:P >1.5 (0.04 to 0.08), whereas the highest estimates were found for Prot% (0.27 to 0.38). Ketosis and displaced abomasum were genetically uncorrelated with milk yield in early lactation. Moderate favorable correlations were found between metabolic diseases and milk composition traits. Ketosis was significantly correlated with Fat% (0.33), F:P ratio (0.30), and F:P ratio >1.5 (0.35) at the first test day, whereas all genetic correlations with milk composition traits at the second test day were not significant and close to zero. Significant favorable genetic correlations were also found between displaced abomasum and F:P ratio (0.26), F:P ratio >1.5 (0.25) and Prot% (-0.19) at the first test day. Also, Prot% at the second test day was significantly correlated (-0.16) with displaced abomasum. Overall, a higher Fat% and F:P ratio and a lower Prot% at the first test day were associated with an increased susceptibility to metabolic diseases. As genetic correlations between metabolic diseases and F:P ratio were far from unity, dairy producers should be encouraged to keep accurate and complete health data. This will be expected to yield to more accurate genetic evaluations for metabolic diseases. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Hall, Steven R.; Walker, Bruce K.
1990-01-01
A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.
Variance change point detection for fractional Brownian motion based on the likelihood ratio test
NASA Astrophysics Data System (ADS)
Kucharczyk, Daniel; Wyłomańska, Agnieszka; Sikora, Grzegorz
2018-01-01
Fractional Brownian motion is one of the main stochastic processes used for describing the long-range dependence phenomenon for self-similar processes. It appears that for many real time series, characteristics of the data change significantly over time. Such behaviour one can observe in many applications, including physical and biological experiments. In this paper, we present a new technique for the critical change point detection for cases where the data under consideration are driven by fractional Brownian motion with a time-changed diffusion coefficient. The proposed methodology is based on the likelihood ratio approach and represents an extension of a similar methodology used for Brownian motion, the process with independent increments. Here, we also propose a statistical test for testing the significance of the estimated critical point. In addition to that, an extensive simulation study is provided to test the performance of the proposed method.
Small, high pressure ratio compressor: Aerodynamic and mechanical design
NASA Technical Reports Server (NTRS)
Bryce, C. A.; Erwin, J. R.; Perrone, G. L.; Nelson, E. L.; Tu, R. K.; Bosco, A.
1973-01-01
The Small, High-Pressure-Ratio Compressor Program was directed toward the analysis, design, and fabrication of a centrifugal compressor providing a 6:1 pressure ratio and an airflow rate of 2.0 pounds per second. The program consists of preliminary design, detailed areodynamic design, mechanical design, and mechanical acceptance tests. The preliminary design evaluate radial- and backward-curved blades, tandem bladed impellers, impeller-and diffuser-passage boundary-layer control, and vane, pipe, and multiple-stage diffusers. Based on this evaluation, a configuration was selected for detailed aerodynamic and mechanical design. Mechanical acceptance test was performed to demonstrate that mechanical design objectives of the research package were met.
Sensitive albuminuria analysis using dye-binding based test strips.
Delanghe, Joris R; Himpe, Jonas; De Cock, Naomi; Delanghe, Sigurd; De Herde, Kevin; Stove, Veronique; Speeckaert, Marijn M
2017-08-01
Populations at increased risk for chronic kidney disease should be screened for albuminuria. Possibilities of advanced urine strip readers based on complementary metal oxide semiconductor (CMOS) sensor technology were investigated for obtaining quantitative albuminuria results. Reflectance data of test strips (Sysmex UFC 3500 reader+CMOS) were compared with albuminuria (BNII) and with proteinuria (Cobas 8000). Urinary creatinine was assayed using a Jaffe-based creatinine assay (Cobas 8000). Calibration curve was made between 11.5 and 121.5mg/L with detection limit of 5.5mg/L. Within-run CV values of reflectance data were 0.21% (UC-Control L; 10mg/L) and 0.37% (UC-Control H; >150mg/L) for albumin, and 0.71%/3.97% for creatinine. Between-run CV values were 0.24%/0.42% for albumin and 0.93%/5.13% for creatinine. A strong correlation (r=0.92) was obtained between albuminuria (BNII) and protein strip reflectance data. Creatinine reflectance data correlated well with Jaffe-based urinary creatinine data (r=0.90). Albumin:creatinine ratio obtained by test strip and by wet chemistry showed a good correlation (r=0.59). Carbamylated, glycated and partially hydrolyzed isoforms of albumin could be detected by test strip. Dye-binding based albumin test strip assay in combination with a CMOS based reader would potentially allow quantitative analysis of albuminuria and determination of albumin:creatinine ratio. Copyright © 2017 Elsevier B.V. All rights reserved.
Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh
2016-01-01
Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.
Rodríguez-Escudero, Juan Pablo; López-Jiménez, Francisco; Trejo-Gutiérrez, Jorge F
2011-01-01
This article reviews different characteristics of validity in a clinical diagnostic test. In particular, we emphasize the likelihood ratio as an instrument that facilitates the use of epidemiologic concepts in clinical diagnosis.
Szyda, Joanna; Liu, Zengting; Zatoń-Dobrowolska, Magdalena; Wierzbicki, Heliodor; Rzasa, Anna
2008-01-01
We analysed data from a selective DNA pooling experiment with 130 individuals of the arctic fox (Alopex lagopus), which originated from 2 different types regarding body size. The association between alleles of 6 selected unlinked molecular markers and body size was tested by using univariate and multinomial logistic regression models, applying odds ratio and test statistics from the power divergence family. Due to the small sample size and the resulting sparseness of the data table, in hypothesis testing we could not rely on the asymptotic distributions of the tests. Instead, we tried to account for data sparseness by (i) modifying confidence intervals of odds ratio; (ii) using a normal approximation of the asymptotic distribution of the power divergence tests with different approaches for calculating moments of the statistics; and (iii) assessing P values empirically, based on bootstrap samples. As a result, a significant association was observed for 3 markers. Furthermore, we used simulations to assess the validity of the normal approximation of the asymptotic distribution of the test statistics under the conditions of small and sparse samples.
Patient or physician preferences for decision analysis: the prenatal genetic testing decision.
Heckerling, P S; Verp, M S; Albert, N
1999-01-01
The choice between amniocentesis and chorionic villus sampling for prenatal genetic testing involves tradeoffs of the benefits and risks of the tests. Decision analysis is a method of explicitly weighing such tradeoffs. The authors examined the relationship between prenatal test choices made by patients and the choices prescribed by decision-analytic models based on their preferences, and separate models based on the preferences of their physicians. Preferences were assessed using written scenarios describing prenatal testing outcomes, and were recorded on linear rating scales. After adjustment for sociodemographic and obstetric confounders, test choice was significantly associated with the choice of decision models based on patient preferences (odds ratio 4.44; Cl, 2.53 to 7.78), but not with the choice of models based on the preferences of the physicians (odds ratio 1.60; Cl, 0.79 to 3.26). Agreement between decision analyses based on patient preferences and on physician preferences was little better than chance (kappa = 0.085+/-0.063). These results were robust both to changes in the decision-analytic probabilities and to changes in the model structure itself to simulate non-expected utility decision rules. The authors conclude that patient but not physician preferences, incorporated in decision models, correspond to the choice of amniocentesis or chorionic villus sampling made by the patient. Nevertheless, because patient preferences were assessed after referral for genetic testing, prospective preference-assessment studies will be necessary to confirm this association.
Correlation Between Cometary Gas/Dust Ratios and Heliocentric Distance
NASA Astrophysics Data System (ADS)
Harrington, Olga; Womack, Maria; Lastra, Nathan
2017-10-01
We compiled CO-based gas/dust ratios for several comets out to heliocentric distances, rh, of 8 au to probe whether there is a noticeable change in comet behavior over the range that water-ice sublimation starts. Previously, gas/dust ratios were calculated for an ensemble of comets using Q(CO2)/efp values derived from infrared measurements, which showed that the gas/dust ratio follows a rh-2 within 4 AU, but is flat at greater distances (Bauer et al. 2015). Our project focuses on gas/dust ratios for which CO is assumed to be the dominant gas, in order to test whether similar breaks in slope occur for CO. The gas/dust ratios were calculated from measurements of CO production rates (mostly from millimeter-wavelength spectroscopy) and reflected sunlight of comets (mostly via reported visual magnitudes of dusty comets). We present our new CO-based gas/dust ratios at different heliocentric distances, compare them to existing CO2-based gas/dust ratios, and discuss implications for CO-driven and CO2-driven activity. We discuss O.H. acknowledges support from the Hartmann Student Travel Grant program. M.W. acknowledges support from NSF grant AST-1615917.
Du, Weiqi; Zhang, Gaofei; Ye, Liangchen
2016-01-01
Micromirror-based scanning displays have been the focus of a variety of applications. Lissajous scanning displays have advantages in terms of power consumption; however, the image quality is not good enough. The main reason for this is the varying size and the contrast ratio of pixels at different positions of the image. In this paper, the Lissajous scanning trajectory is analyzed and a new method based on the diamond pixel is introduced to Lissajous displays. The optical performance of micromirrors is discussed. A display system demonstrator is built, and tests of resolution and contrast ratio are conducted. The test results show that the new Lissajous scanning method can be used in displays by using diamond pixels and image quality remains stable at different positions. PMID:27187390
Du, Weiqi; Zhang, Gaofei; Ye, Liangchen
2016-05-11
Micromirror-based scanning displays have been the focus of a variety of applications. Lissajous scanning displays have advantages in terms of power consumption; however, the image quality is not good enough. The main reason for this is the varying size and the contrast ratio of pixels at different positions of the image. In this paper, the Lissajous scanning trajectory is analyzed and a new method based on the diamond pixel is introduced to Lissajous displays. The optical performance of micromirrors is discussed. A display system demonstrator is built, and tests of resolution and contrast ratio are conducted. The test results show that the new Lissajous scanning method can be used in displays by using diamond pixels and image quality remains stable at different positions.
Lotfy, Hayam M; Fayez, Yasmin M; Michael, Adel M; Nessim, Christine K
2016-02-15
Smart, sensitive, simple and accurate spectrophotometric methods were developed and validated for the quantitative determination of a binary mixture of mebeverine hydrochloride (MVH) and chlordiazepoxide (CDZ) without prior separation steps via different manipulating pathways. These pathways were applied either on zero order absorption spectra namely, absorbance subtraction (AS) or based on the recovered zero order absorption spectra via a decoding technique namely, derivative transformation (DT) or via ratio spectra namely, ratio subtraction (RS) coupled with extended ratio subtraction (EXRS), spectrum subtraction (SS), constant multiplication (CM) and constant value (CV) methods. The manipulation steps applied on the ratio spectra are namely, ratio difference (RD) and amplitude modulation (AM) methods or applying a derivative to these ratio spectra namely, derivative ratio (DD(1)) or second derivative (D(2)). Finally, the pathway based on the ratio spectra of derivative spectra is namely, derivative subtraction (DS). The specificity of the developed methods was investigated by analyzing the laboratory mixtures and was successfully applied for their combined dosage form. The proposed methods were validated according to ICH guidelines. These methods exhibited linearity in the range of 2-28μg/mL for mebeverine hydrochloride and 1-12μg/mL for chlordiazepoxide. The obtained results were statistically compared with those of the official methods using Student t-test, F-test, and one way ANOVA, showing no significant difference with respect to accuracy and precision. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lotfy, Hayam M.; Fayez, Yasmin M.; Michael, Adel M.; Nessim, Christine K.
2016-02-01
Smart, sensitive, simple and accurate spectrophotometric methods were developed and validated for the quantitative determination of a binary mixture of mebeverine hydrochloride (MVH) and chlordiazepoxide (CDZ) without prior separation steps via different manipulating pathways. These pathways were applied either on zero order absorption spectra namely, absorbance subtraction (AS) or based on the recovered zero order absorption spectra via a decoding technique namely, derivative transformation (DT) or via ratio spectra namely, ratio subtraction (RS) coupled with extended ratio subtraction (EXRS), spectrum subtraction (SS), constant multiplication (CM) and constant value (CV) methods. The manipulation steps applied on the ratio spectra are namely, ratio difference (RD) and amplitude modulation (AM) methods or applying a derivative to these ratio spectra namely, derivative ratio (DD1) or second derivative (D2). Finally, the pathway based on the ratio spectra of derivative spectra is namely, derivative subtraction (DS). The specificity of the developed methods was investigated by analyzing the laboratory mixtures and was successfully applied for their combined dosage form. The proposed methods were validated according to ICH guidelines. These methods exhibited linearity in the range of 2-28 μg/mL for mebeverine hydrochloride and 1-12 μg/mL for chlordiazepoxide. The obtained results were statistically compared with those of the official methods using Student t-test, F-test, and one way ANOVA, showing no significant difference with respect to accuracy and precision.
A Ratio Test of Interrater Agreement with High Specificity
ERIC Educational Resources Information Center
Cousineau, Denis; Laurencelle, Louis
2015-01-01
Existing tests of interrater agreements have high statistical power; however, they lack specificity. If the ratings of the two raters do not show agreement but are not random, the current tests, some of which are based on Cohen's kappa, will often reject the null hypothesis, leading to the wrong conclusion that agreement is present. A new test of…
EXSPRT: An Expert Systems Approach to Computer-Based Adaptive Testing.
ERIC Educational Resources Information Center
Frick, Theodore W.; And Others
Expert systems can be used to aid decision making. A computerized adaptive test (CAT) is one kind of expert system, although it is not commonly recognized as such. A new approach, termed EXSPRT, was devised that combines expert systems reasoning and sequential probability ratio test stopping rules. EXSPRT-R uses random selection of test items,…
Order-restricted inference for means with missing values.
Wang, Heng; Zhong, Ping-Shou
2017-09-01
Missing values appear very often in many applications, but the problem of missing values has not received much attention in testing order-restricted alternatives. Under the missing at random (MAR) assumption, we impute the missing values nonparametrically using kernel regression. For data with imputation, the classical likelihood ratio test designed for testing the order-restricted means is no longer applicable since the likelihood does not exist. This article proposes a novel method for constructing test statistics for assessing means with an increasing order or a decreasing order based on jackknife empirical likelihood (JEL) ratio. It is shown that the JEL ratio statistic evaluated under the null hypothesis converges to a chi-bar-square distribution, whose weights depend on missing probabilities and nonparametric imputation. Simulation study shows that the proposed test performs well under various missing scenarios and is robust for normally and nonnormally distributed data. The proposed method is applied to an Alzheimer's disease neuroimaging initiative data set for finding a biomarker for the diagnosis of the Alzheimer's disease. © 2017, The International Biometric Society.
Towards a framework for testing general relativity with extreme-mass-ratio-inspiral observations
NASA Astrophysics Data System (ADS)
Chua, A. J. K.; Hee, S.; Handley, W. J.; Higson, E.; Moore, C. J.; Gair, J. R.; Hobson, M. P.; Lasenby, A. N.
2018-07-01
Extreme-mass-ratio-inspiral observations from future space-based gravitational-wave detectors such as LISA will enable strong-field tests of general relativity with unprecedented precision, but at prohibitive computational cost if existing statistical techniques are used. In one such test that is currently employed for LIGO black hole binary mergers, generic deviations from relativity are represented by N deformation parameters in a generalized waveform model; the Bayesian evidence for each of its 2N combinatorial submodels is then combined into a posterior odds ratio for modified gravity over relativity in a null-hypothesis test. We adapt and apply this test to a generalized model for extreme-mass-ratio inspirals constructed on deformed black hole spacetimes, and focus our investigation on how computational efficiency can be increased through an evidence-free method of model selection. This method is akin to the algorithm known as product-space Markov chain Monte Carlo, but uses nested sampling and improved error estimates from a rethreading technique. We perform benchmarking and robustness checks for the method, and find order-of-magnitude computational gains over regular nested sampling in the case of synthetic data generated from the null model.
Towards a framework for testing general relativity with extreme-mass-ratio-inspiral observations
NASA Astrophysics Data System (ADS)
Chua, A. J. K.; Hee, S.; Handley, W. J.; Higson, E.; Moore, C. J.; Gair, J. R.; Hobson, M. P.; Lasenby, A. N.
2018-04-01
Extreme-mass-ratio-inspiral observations from future space-based gravitational-wave detectors such as LISA will enable strong-field tests of general relativity with unprecedented precision, but at prohibitive computational cost if existing statistical techniques are used. In one such test that is currently employed for LIGO black-hole binary mergers, generic deviations from relativity are represented by N deformation parameters in a generalised waveform model; the Bayesian evidence for each of its 2N combinatorial submodels is then combined into a posterior odds ratio for modified gravity over relativity in a null-hypothesis test. We adapt and apply this test to a generalised model for extreme-mass-ratio inspirals constructed on deformed black-hole spacetimes, and focus our investigation on how computational efficiency can be increased through an evidence-free method of model selection. This method is akin to the algorithm known as product-space Markov chain Monte Carlo, but uses nested sampling and improved error estimates from a rethreading technique. We perform benchmarking and robustness checks for the method, and find order-of-magnitude computational gains over regular nested sampling in the case of synthetic data generated from the null model.
Analysis of large system black box verification test data
NASA Technical Reports Server (NTRS)
Clapp, Kenneth C.; Iyer, Ravishankar Krishnan
1993-01-01
Issues regarding black box, large systems verification are explored. It begins by collecting data from several testing teams. An integrated database containing test, fault, repair, and source file information is generated. Intuitive effectiveness measures are generated using conventional black box testing results analysis methods. Conventional analysts methods indicate that the testing was effective in the sense that as more tests were run, more faults were found. Average behavior and individual data points are analyzed. The data is categorized and average behavior shows a very wide variation in number of tests run and in pass rates (pass rates ranged from 71 percent to 98 percent). The 'white box' data contained in the integrated database is studied in detail. Conservative measures of effectiveness are discussed. Testing efficiency (ratio of repairs to number of tests) is measured at 3 percent, fault record effectiveness (ratio of repairs to fault records) is measured at 55 percent, and test script redundancy (ratio of number of failed tests to minimum number of tests needed to find the faults) ranges from 4.2 to 15.8. Error prone source files and subsystems are identified. A correlational mapping of test functional area to product subsystem is completed. A new adaptive testing process based on real-time generation of the integrated database is proposed.
Zhang, Yun; Baheti, Saurabh; Sun, Zhifu
2018-05-01
High-throughput bisulfite methylation sequencing such as reduced representation bisulfite sequencing (RRBS), Agilent SureSelect Human Methyl-Seq (Methyl-seq) or whole-genome bisulfite sequencing is commonly used for base resolution methylome research. These data are represented either by the ratio of methylated cytosine versus total coverage at a CpG site or numbers of methylated and unmethylated cytosines. Multiple statistical methods can be used to detect differentially methylated CpGs (DMCs) between conditions, and these methods are often the base for the next step of differentially methylated region identification. The ratio data have a flexibility of fitting to many linear models, but the raw count data take consideration of coverage information. There is an array of options in each datatype for DMC detection; however, it is not clear which is an optimal statistical method. In this study, we systematically evaluated four statistic methods on methylation ratio data and four methods on count-based data and compared their performances with regard to type I error control, sensitivity and specificity of DMC detection and computational resource demands using real RRBS data along with simulation. Our results show that the ratio-based tests are generally more conservative (less sensitive) than the count-based tests. However, some count-based methods have high false-positive rates and should be avoided. The beta-binomial model gives a good balance between sensitivity and specificity and is preferred method. Selection of methods in different settings, signal versus noise and sample size estimation are also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batchelor, D.B.; Carreras, B.A.; Hirshman, S.P.
Significant progress has been made in the development of new modest-size compact stellarator devices that could test optimization principles for the design of a more attractive reactor. These are 3 and 4 field period low-aspect-ratio quasi-omnigenous (QO) stellarators based on an optimization method that targets improved confinement, stability, ease of coil design, low-aspect-ratio, and low bootstrap current.
Influence of rock-soil spectral variation on the assessment of green biomass
NASA Technical Reports Server (NTRS)
Elvidge, C. D.; Lyon, R. J. P.
1985-01-01
A comparison of how n-spaced and ratio-based vegetation indices respond to rock and soil spectral variation is made, using a set of ground-based reflectance spectra and airborne Thematic Mapper imagery of the Virginia Range, NV. The influence of variations in rock-soil brightness on ratio-based vegetation indices is also discussed. It is shown that of all the vegetation indices tested, the perperdicular vegetation index is the most appropriate for use in multispectral imagery of arid and semiarid regions where there is a wide variation in substrate characteristics.
NASA Technical Reports Server (NTRS)
Schuldenfrei, Marvin; Comisarow, Paul; Goodson, Kenneth W
1947-01-01
Tests were made of an airplane model having a 45.1 degree swept-back wing with aspect ratio 2.50 and taper ratio 0.42 and a 42.8 degree swept-back horizontal tail with aspect ratio 3.87 and taper ratio 0.49 to determine its low-speed stability and control characteristics. The test Reynolds number was 2.87 x 10(6) based on a mean aerodynamic chord of 2.47 feet except for some of the aileron tests which were made at a Reynolds number of 2.05 x 10(6). With the horizontal tail located near the fuselage juncture on the vertical tail, model results indicated static longitudinal instability above a lift coefficient that was 0.15 below the lift coefficient at which stall occurred. Static longitudinal stability, however, was manifested throughout the life range with the horizontal tail located near the top of the vertical tail. The use of 10 degrees negative dihedral on the wing had little effect on the static longitudinal stability characteristics. Preliminary tests of the complete model revealed an undesirable flat spot in the yawing-moment curves at low angles of attack, the directional stability being neutral for yaw angles of plus-or-minus 2 degrees. This undesirable characteristic was improved by replacing the thick original vertical tail with a thin vertical tail and by flattening the top of the dorsal fairing.
Performance characterization of a single bi-axial scanning MEMS mirror-based head-worn display
NASA Astrophysics Data System (ADS)
Liang, Minhua
2002-06-01
The NomadTM Personal Display System is a head-worn display (HWD) with a see-through, high-resolution, high-luminance display capability. It is based on a single bi-axial scanning MEMS mirror. In the Nomad HWD system, a red laser diode emits a beam of light that is scanned bi-axially by a single MEMS mirror. A diffractive beam diffuser and an ocular expand the beam to form a 12mm exit pupil for comfortable viewing. The Nomad display has an SVGA (800x600) resolution, 60Hz frame rate, 23-degree horizontal field of view (FOV) and 3:4 vertical to horizontal aspect ratio, a luminance of 800~900 foot-Lamberts, see-through capability, 30mm eye-relief distance, and 1-foot to infinity focusing adjustment. We have characterized the performance parameters, such as field of view, distortion, contrast ratio (4x4 black and white checker board), modulation depth, exit pupil size, eye relief distance, maximum luminance, dynamic range ratio (full-on-to-full-off ratio), dimming ratio, and luminance uniformity at image plane. The Class-1 eye-safety requirements per IEC 60825-1 Amendment 2 (CDRH Laser Notice No. 50) are analyzed and verified by experiments. The paper describes all of the testing methods and set-ups as well as the representative test results. The test results demonstrate that the Nomad display is an eye-safe display product with good image quality and good user ergonomics.
NASA Astrophysics Data System (ADS)
Ramasamy, Shamala; Abdullah, Mohd Mustafa Al Bakri; Huang, Yue; Hussin, Kamarudin; Wang, Jin; Shahedan, Noor Fifinatasha
2017-09-01
Geopolymer is an uprising technology that is being studied worldwide. Geopolymer raw materials are basically aluminosilicate source materials. However, this technology is yet to infiltrate into pipelines and coating industries which initiated our research idea. The idea of creating universal geopolymer based coating material is mainly to help oil and gas industry reduce its maintenance cost. Kaolin based geopolymer paste was coated on glass reinforced epoxy (GRE) substrates which are majorly used as pipeline material in the oil and gas industry at Saudi Arabia. Kaolin and white clay was chosen as raw material to study the possibilities of utilizing underused aluminosilicate raw materials for geopolymer coating. To obtain suitable formulation, Na2SiO3/NaOH ratio was varied from 0.40 untill 0.60 while other parameters such as solid/liquid ratio and NaOH molarity were kept constant at values as per previous works. Geopolymer coated GRE substrates were then subjected to water absorption, flexural strength and hardness test to validate our findings. Water absorption is a crucial test as for coating materials which justifies the pratical usability of the coating product. Upon testing, kaolin and white clay based geopolymer coating each shows promising properties at Na2SiO3/NaOH ratio of 0.45 and 0.50 each.
NASA Technical Reports Server (NTRS)
Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.
1986-01-01
The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.
Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning
ERIC Educational Resources Information Center
Li, Zhushan
2014-01-01
Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…
ERIC Educational Resources Information Center
Moses, Tim; Holland, Paul W.
2010-01-01
In this study, eight statistical strategies were evaluated for selecting the parameterizations of loglinear models for smoothing the bivariate test score distributions used in nonequivalent groups with anchor test (NEAT) equating. Four of the strategies were based on significance tests of chi-square statistics (Likelihood Ratio, Pearson,…
Yost, Fred; Hosking, Floyd M.; Jellison, James L.; Short, Bruce; Giversen, Terri; Reed, Jimmy R.
1998-01-01
A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time.
Systems Biology and Ratio-Based, Real-Time Disease Surveillance.
Fair, J M; Rivas, A L
2015-08-01
Most infectious disease surveillance methods are not well fit for early detection. To address such limitation, here we evaluated a ratio- and Systems Biology-based method that does not require prior knowledge on the identity of an infective agent. Using a reference group of birds experimentally infected with West Nile virus (WNV) and a problem group of unknown health status (except that they were WNV-negative and displayed inflammation), both groups were followed over 22 days and tested with a system that analyses blood leucocyte ratios. To test the ability of the method to discriminate small data sets, both the reference group (n = 5) and the problem group (n = 4) were small. The questions of interest were as follows: (i) whether individuals presenting inflammation (disease-positive or D+) can be distinguished from non-inflamed (disease-negative or D-) birds, (ii) whether two or more D+ stages can be detected and (iii) whether sample size influences detection. Within the problem group, the ratio-based method distinguished the following: (i) three (one D- and two D+) data classes; (ii) two (early and late) inflammatory stages; (iii) fast versus regular or slow responders; and (iv) individuals that recovered from those that remained inflamed. Because ratios differed in larger magnitudes (up to 48 times larger) than percentages, it is suggested that data patterns are likely to be recognized when disease surveillance methods are designed to measure inflammation and utilize ratios. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.
The Effect of Alkaline Activator Ratio on the Compressive Strength of Fly Ash-Based Geopolymer Paste
NASA Astrophysics Data System (ADS)
Lăzărescu, A. V.; Szilagyi, H.; Baeră, C.; Ioani, A.
2017-06-01
Alkaline activation of fly ash is a particular procedure in which ash resulting from a power plant combined with a specific alkaline activator creates a solid material when dried at a certain temperature. In order to obtain desirable compressive strengths, the mix design of fly ash based geopolymer pastes should be explored comprehensively. To determine the preliminary compressive strength for fly ash based geopolymer paste using Romanian material source, various ratios of Na2SiO3 solution/ NaOH solution were produced, keeping the fly ash/alkaline activator ratio constant. All the mixes were then cured at 70 °C for 24 hours and tested at 2 and 7 days, respectively. The aim of this paper is to present the preliminary compressive strength results for producing fly ash based geopolymer paste using Romanian material sources, the effect of alkaline activators ratio on the compressive strength and studying the directions for future research.
The effect of changes in compression ratio upon engine performance
NASA Technical Reports Server (NTRS)
Sparrow, Stanwood W
1925-01-01
This report is based upon engine tests made at the Bureau of Standards during 1920, 1921, 1922, and 1923. The majority of these tests were of aviation engines and were made in the Altitude Laboratory. For a small portion of the work a single cylinder experimental engine was used. This, however, was operated only at sea-level pressures. The report shows that an increase in break horsepower and a decrease in the pounds of fuel used per brake horsepower hour usually results from an increase in compression ratio. This holds true at least up to the highest ratio investigated, 14 to 1, provided there is no serious preignition or detonation at any ratio. To avoid preignition and detonation when employing high-compression ratios, it is often necessary to use some fuel other than gasoline. It has been found that the consumption of some of these fuels in pounds per brake horsepower hour is so much greater than the consumption of gasoline that it offsets the decrease derived from the use of the high-compression ratio. The changes in indicated thermal efficiency with changes in compression ratio are in close agreement with what would be anticipated from a consideration of the air cycle efficiencies at the various ratios. In so far as these tests are concerned there is no evidence that a change in compression ratio produces an appreciable, consistent change in friction horsepower, volumetric efficiency, or in the range of fuel-air ratios over which the engine can operate. The ratio between the heat loss to the jacket water and the heat converted into brake horsepower or indicated horsepower decreases with increase in compression ratio. (author)
Buccal swab as a reliable predictor for X inactivation ratio in inaccessible tissues.
de Hoon, Bas; Monkhorst, Kim; Riegman, Peter; Laven, Joop S E; Gribnau, Joost
2015-11-01
As a result of the epigenetic phenomenon of X chromosome inactivation (XCI) every woman is a mosaic of cells with either an inactive paternal X chromosome or an inactive maternal X chromosome. The ratio between inactive paternal and maternal X chromosomes is different for every female individual, and can influence an X-encoded trait or disease. A multitude of X linked conditions is known, and for many of them it is recognised that the phenotype in affected female carriers of the causative mutation is modulated by the XCI ratio. To predict disease severity an XCI ratio is usually determined in peripheral blood samples. However, the correlation between XCI ratios in peripheral blood and disease affected tissues, that are often inaccessible, is poorly understood. Here, we tested several tissues obtained from autopsies of 12 female individuals for patch size and XCI ratio. XCI ratios were analysed using methyl-sensitive PCR-based assays for the AR, PCSK1N and SLITRK4 loci. XCI patch size was analysed by testing the XCI ratio of tissue samples with decreasing size. XCI patch size was analysed for liver, muscle, ovary and brain samples and was found too small to confound testing for XCI ratio in these tissues. XCI ratios were determined in the easily accessible tissues, blood, buccal epithelium and hair follicle, and compared with ratios in several inaccessible tissues. Buccal epithelium is preferable over peripheral blood for predicting XCI ratios of inaccessible tissues. Ovary is the only inaccessible tissue showing a poor correlation to blood and buccal epithelium, but has a good correlation to hair follicle instead. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
ERIC Educational Resources Information Center
Egberink, Iris J. L.; Meijer, Rob R.; Tendeiro, Jorge N.
2015-01-01
A popular method to assess measurement invariance of a particular item is based on likelihood ratio tests with all other items as anchor items. The results of this method are often only reported in terms of statistical significance, and researchers proposed different methods to empirically select anchor items. It is unclear, however, how many…
Van Hoeyveld, Erna; Nickmans, Silvie; Ceuppens, Jan L; Bossuyt, Xavier
2015-10-23
Cut-off values and predictive values are used for the clinical interpretation of specific IgE antibody results. However, cut-off levels are not well defined, and predictive values are dependent on the prevalence of disease. The objective of this study was to document clinically relevant diagnostic accuracy of specific IgE for inhalant allergens (grass pollen and birch pollen) based on test result interval-specific likelihood ratios. Likelihood ratios are independent of the prevalence and allow to provide diagnostic accuracy information for test result intervals. In a prospective study we included consecutive adult patients presenting at an allergy clinic with complaints of rhinitis or rhinoconjunctivitis. The standard for diagnosis was a suggestive clinical history of grass or birch pollen allergy and a positive skin test. Specific IgE was determined with the ImmunoCAP Fluorescence Enzyme Immuno-Assay. We established specific IgE test result interval related likelihood ratios for clinical allergy to inhalant allergens (grass pollen, rPhl p 1,5, birch pollen, rBet v 1). The likelihood ratios for allergy increased with increasing specific IgE antibody levels. The likelihood ratio was <0.03 for specific IgE <0.1 kU/L, between 0.1 and 1.4 for specific IgE between 0.1 kU/L and 0.35 kU/L, between 1.4 and 4.2 for specific IgE between 0.35 kU/L and 3.5 kU/L, >6.3 for specific IgE>0.7, and very high (∞) for specific IgE >3.5 kU/L. Test result interval specific likelihood ratios provide a useful tool for the interpretation of specific IgE test results for inhalant allergens. Copyright © 2015 Elsevier B.V. All rights reserved.
Mix Proportion Design of Asphalt Concrete
NASA Astrophysics Data System (ADS)
Wu, Xianhu; Gao, Lingling; Du, Shoujun
2017-12-01
Based on the gradation of AC and SMA, this paper designs a new type of anti slide mixture with two types of advantages. Chapter introduces the material selection, ratio of ore mixture ratio design calculation, and determine the optimal asphalt content test and proportioning design of asphalt concrete mix. This paper introduces the new technology of mix proportion.
ERIC Educational Resources Information Center
Suh, Youngsuk; Talley, Anna E.
2015-01-01
This study compared and illustrated four differential distractor functioning (DDF) detection methods for analyzing multiple-choice items. The log-linear approach, two item response theory-model-based approaches with likelihood ratio tests, and the odds ratio approach were compared to examine the congruence among the four DDF detection methods.…
ERIC Educational Resources Information Center
Zan, Xinxing Anna; Yoon, Sang Won; Khasawneh, Mohammad; Srihari, Krishnaswami
2013-01-01
In an effort to develop a low-cost and user-friendly forecasting model to minimize forecasting error, we have applied average and exponentially weighted return ratios to project undergraduate student enrollment. We tested the proposed forecasting models with different sets of historical enrollment data, such as university-, school-, and…
Numerical Simulation of Earth Pressure on Head Chamber of Shield Machine with FEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Shouju; Kang Chengang; Sun, Wei
2010-05-21
Model parameters of conditioned soils in head chamber of shield machine are determined based on tree-axial compression tests in laboratory. The loads acting on tunneling face are estimated according to static earth pressure principle. Based on Duncan-Chang nonlinear elastic constitutive model, the earth pressures on head chamber of shield machine are simulated in different aperture ratio cases for rotating cutterhead of shield machine. Relationship between pressure transportation factor and aperture ratio of shield machine is proposed by using aggression analysis.
NASA Astrophysics Data System (ADS)
Hwang, James Ho-Jin; Duran, Adam
2016-08-01
Most of the times pyrotechnic shock design and test requirements for space systems are provided in Shock Response Spectrum (SRS) without the input time history. Since the SRS does not describe the input or the environment, a decomposition method is used to obtain the source time history. The main objective of this paper is to develop a decomposition method producing input time histories that can satisfy the SRS requirement based on the pyrotechnic shock test data measured from a mechanical impact test apparatus. At the heart of this decomposition method is the statistical representation of the pyrotechnic shock test data measured from the MIT Lincoln Laboratory (LL) designed Universal Pyrotechnic Shock Simulator (UPSS). Each pyrotechnic shock test data measured at the interface of a test unit has been analyzed to produce the temporal peak acceleration, Root Mean Square (RMS) acceleration, and the phase lag at each band center frequency. Maximum SRS of each filtered time history has been calculated to produce a relationship between the input and the response. Two new definitions are proposed as a result. The Peak Ratio (PR) is defined as the ratio between the maximum SRS and the temporal peak acceleration at each band center frequency. The ratio between the maximum SRS and the RMS acceleration is defined as the Energy Ratio (ER) at each band center frequency. Phase lag is estimated based on the time delay between the temporal peak acceleration at each band center frequency and the peak acceleration at the lowest band center frequency. This stochastic process has been applied to more than one hundred pyrotechnic shock test data to produce probabilistic definitions of the PR, ER, and the phase lag. The SRS is decomposed at each band center frequency using damped sinusoids with the PR and the decays obtained by matching the ER of the damped sinusoids to the ER of the test data. The final step in this stochastic SRS decomposition process is the Monte Carlo (MC) simulation. The MC simulation identifies combinations of the PR and decays that can meet the SRS requirement at each band center frequency. Decomposed input time histories are produced by summing the converged damped sinusoids with the MC simulation of the phase lag distribution.
NASA Technical Reports Server (NTRS)
Jorgensen, L. H.; Nelson, E. R.
1976-01-01
An experimental investigation was conducted by wind tunnel to measure the static aerodynamic characteristics for bodies of circular and elliptic cross section with various thin flat plate wings and a thin tail consisting of horizontal and vertical parts. The wings had aspect ratios of 4 and taper ratios of about 0, 0.25, and 0.5. Two additional wings, which had taper ratios near 0.25 and aspect ratios of about 3 and 5, were also tested in combination with the bodies and tail. All wings had about the same planform area. The exposed area of the horizontal portion of the tail was about 33 to 36 percent of the exposed area of the wings. The exposed area of the vertical tail fin was about 22 to 24 percent of the exposed area of the wings. The elliptic body, with an a/b = 2 cross section, had the same length and axial distribution of cross sectional area as the circular body. The circular body had a cylindrical aftersection of fineness ratio 7, and it was tested with the wings and tail in combination with tangent ogive noses that had fineness ratios of 2.5, 3.0, 3.5, and 5.0. In addition, an ogive nose with a rounded tip and an ogive nose with two different nose strake arrangements were used. Nineteen configuration combinations were tested at Mach numbers of 0.6, 0.9, 1.5, and 2.0 at angles of attack from 0 to 58 deg. The Reynolds numbers, based on body base diameter, were about 4.3 X 100,000.
PBOOST: a GPU-based tool for parallel permutation tests in genome-wide association studies.
Yang, Guangyuan; Jiang, Wei; Yang, Qiang; Yu, Weichuan
2015-05-01
The importance of testing associations allowing for interactions has been demonstrated by Marchini et al. (2005). A fast method detecting associations allowing for interactions has been proposed by Wan et al. (2010a). The method is based on likelihood ratio test with the assumption that the statistic follows the χ(2) distribution. Many single nucleotide polymorphism (SNP) pairs with significant associations allowing for interactions have been detected using their method. However, the assumption of χ(2) test requires the expected values in each cell of the contingency table to be at least five. This assumption is violated in some identified SNP pairs. In this case, likelihood ratio test may not be applicable any more. Permutation test is an ideal approach to checking the P-values calculated in likelihood ratio test because of its non-parametric nature. The P-values of SNP pairs having significant associations with disease are always extremely small. Thus, we need a huge number of permutations to achieve correspondingly high resolution for the P-values. In order to investigate whether the P-values from likelihood ratio tests are reliable, a fast permutation tool to accomplish large number of permutations is desirable. We developed a permutation tool named PBOOST. It is based on GPU with highly reliable P-value estimation. By using simulation data, we found that the P-values from likelihood ratio tests will have relative error of >100% when 50% cells in the contingency table have expected count less than five or when there is zero expected count in any of the contingency table cells. In terms of speed, PBOOST completed 10(7) permutations for a single SNP pair from the Wellcome Trust Case Control Consortium (WTCCC) genome data (Wellcome Trust Case Control Consortium, 2007) within 1 min on a single Nvidia Tesla M2090 device, while it took 60 min in a single CPU Intel Xeon E5-2650 to finish the same task. More importantly, when simultaneously testing 256 SNP pairs for 10(7) permutations, our tool took only 5 min, while the CPU program took 10 h. By permuting on a GPU cluster consisting of 40 nodes, we completed 10(12) permutations for all 280 SNP pairs reported with P-values smaller than 1.6 × 10⁻¹² in the WTCCC datasets in 1 week. The source code and sample data are available at http://bioinformatics.ust.hk/PBOOST.zip. gyang@ust.hk; eeyu@ust.hk Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Dementjev, Aleksandr S.; Jovaisa, A.; Silko, Galina; Ciegis, Raimondas
2005-11-01
Based on the developed efficient numerical methods for calculating the propagation of light beams, the alternative methods for measuring the beam radius and propagation ratio proposed in the international standard ISO 11146 are analysed. The specific calculations of the alternative beam propagation ratios Mi2 performed for a number of test beams with a complicated spatial structure showed that the correlation coefficients ci used in the international standard do not establish the universal one-to-one relation between the alternative propagation ratios Mi2 and invariant propagation ratios Mσ2 found by the method of moments.
NASA Technical Reports Server (NTRS)
Carpenter, J. R.; Markley, F. L.; Alfriend, K. T.; Wright, C.; Arcido, J.
2011-01-01
Sequential probability ratio tests explicitly allow decision makers to incorporate false alarm and missed detection risks, and are potentially less sensitive to modeling errors than a procedure that relies solely on a probability of collision threshold. Recent work on constrained Kalman filtering has suggested an approach to formulating such a test for collision avoidance maneuver decisions: a filter bank with two norm-inequality-constrained epoch-state extended Kalman filters. One filter models 1he null hypothesis 1ha1 the miss distance is inside the combined hard body radius at the predicted time of closest approach, and one filter models the alternative hypothesis. The epoch-state filter developed for this method explicitly accounts for any process noise present in the system. The method appears to work well using a realistic example based on an upcoming highly-elliptical orbit formation flying mission.
Yost, F.; Hosking, F.M.; Jellison, J.L.; Short, B.; Giversen, T.; Reed, J.R.
1998-10-27
A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time. 11 figs.
Velayos, Fernando S; Kahn, James G; Sandborn, William J; Feagan, Brian G
2013-06-01
Patients with Crohn's disease who become unresponsive to therapy with tumor necrosis factor antagonists are managed initially with either empiric dose escalation or testing-based strategies. The comparative cost effectiveness of these 2 strategies is unknown. We investigated whether a testing-based strategy is more cost effective than an empiric dose-escalation strategy. A decision analytic model that simulated 2 cohorts of patients with Crohn's disease compared outcomes for the 2 strategies over a 1-year time period. The incremental cost-effectiveness ratio of the empiric strategy was expressed as cost per quality-adjusted life-year (QALY) gained, compared with the testing-based strategy. We performed 1-way, probabilistic, and prespecified secondary analyses. The testing strategy yielded similar QALYs compared with the empiric strategy (0.801 vs 0.800, respectively) but was less expensive ($31,870 vs $37,266, respectively). In sensitivity analyses, the incremental cost-effectiveness ratio of the empiric strategy ranged from $500,000 to more than $5 million per QALY gained. Similar rates of remission (63% vs 66%) and response (28% vs 26%) were achieved through differential use of available interventions. The testing-based strategy resulted in a higher percentage of surgeries (48% vs 34%) and lower percentage use of high-dose biological therapy (41% vs 54%). A testing-based strategy is a cost-effective alternative to the current strategy of empiric dose escalation for managing patients with Crohn's disease who have lost responsiveness to infliximab. The basis for this difference is lower cost at similar outcomes. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Rohyami, Yuli; Anjani, Rafika Debby; Purwanti, Napthalina Putri
2017-03-01
Virgin coconut oil is an excellent product which has result of oil processing business opportunities in the international market. Standardization of virgin coconut oil necessary to satisfy the requirements industry needs. This research is expected as procedure preparation of reference materials. Preparation of virgin coconut oil by Sacharomycescerevisiaeenzyme. Based on the results of this study concluded that the ratio of Saccharomyces cerevisiae can affect the yield of virgin coconut oil produced. The preparation of virgin coconut oil enzymatically using a variety of mass ratio of 0.001 to 0.006% is obtained yield average of 12.40%. The optimum separation of virgin coconut oil on the use of enzymes with a mass ratio of 0.002%. The average water content at a ratio of 0.002% is 0.04 % with a value of uncertainty is 0.005%. The average iodine number in virgin coconut oil produced is 2.4403 ± 0,1974 grams of iodine per 100 grams of oil and optimum iodine number is obtained from the manufacturing process virgin coconut oil with a ratio of 0.006% Saccharomyces cerevisiae. Sacharomycescerevisiae with a ratio of 0.002% results virgin coconut oil with acid number 0.3068 ± 0.1098%. The peroxide value of virgin coconut oil between 0.0108 ± 0.009 to 0.0114 ± 0015milli-equivalent per kilograms. Organoleptic test results and test chemical parameters can be used as the test data that can be developed in prototype preparation of candidate in-house reference material in the testing standards of quality virgin coconut oil.
Advanced Hydrocarbon Fuel Development
NASA Technical Reports Server (NTRS)
Bai, S. Don; Rodgers, Stephen L. (Technical Monitor)
2000-01-01
As a part of a high energy density materials (HEDM) development, the hot fire tests for Quadricyclane, 1,7 Octadiyne, AFRL-1, Biclopropylidene, and CINCH (Dimethyl amino ethyl azide) have been conducted at NASA/MSFC. The first 4 materials for this task are provided from Air Force Research Laboratory at Edward Air Force Base and US Army provided CINCH. The performance of these fuels is compared with RP-1. The preliminary results of these tests are presented. The preliminary results of Quadricyclane tests indicate that the specific impulse and c-star efficiency for quadricyclane at the mixture ratio 1.94 are approximately 5 sec and 105 ft/sec better than the RP-1 at mixture ratio 1.9. The 1,7 Octadiyne test indicate that the specific impulse and c-star efficiency at the mixture ratio 2.1 are approximately -1 sec and 89 ft/sec differ than the RP-1 at mixture ratio 2.04. The Quadricyclane soot buildup at the combustor is a little more than RP-1, but detail study of soot formation is not considered at this time. There was no visual soot buildup for the 1,7 Octadiyne and AFRL-1.
Romanens, Michel; Ackermann, Franz; Spence, John David; Darioli, Roger; Rodondi, Nicolas; Corti, Roberto; Noll, Georg; Schwenkglenks, Matthias; Pencina, Michael
2010-02-01
Cardiovascular risk assessment might be improved with the addition of emerging, new tests derived from atherosclerosis imaging, laboratory tests or functional tests. This article reviews relative risk, odds ratios, receiver-operating curves, posttest risk calculations based on likelihood ratios, the net reclassification improvement and integrated discrimination. This serves to determine whether a new test has an added clinical value on top of conventional risk testing and how this can be verified statistically. Two clinically meaningful examples serve to illustrate novel approaches. This work serves as a review and basic work for the development of new guidelines on cardiovascular risk prediction, taking into account emerging tests, to be proposed by members of the 'Taskforce on Vascular Risk Prediction' under the auspices of the Working Group 'Swiss Atherosclerosis' of the Swiss Society of Cardiology in the future.
NASA Technical Reports Server (NTRS)
DeBonis, J. R.; Trefny, C. J.
2001-01-01
Results of an isolated inlet test for NASA's GTX air-breathing launch vehicle concept are presented. The GTX is a Vertical Take-off/ Horizontal Landing reusable single-stage-to-orbit system powered by a rocket-based combined-cycle propulsion system. Tests were conducted in the NASA Glenn 1- by 1-Foot Supersonic Wind Tunnel during two entries in October 1998 and February 1999. Tests were run from Mach 2.8 to 6. Integrated performance parameters and static pressure distributions are reported. The maximum contraction ratios achieved in the tests were lower than predicted by axisymmetric Reynolds-averaged Navier-Stokes computational fluid dynamics (CFD). At Mach 6, the maximum contraction ratio was roughly one-half of the CFD value of 16. The addition of either boundary-layer trip strips or vortex generators had a negligible effect on the maximum contraction ratio. A shock boundary-layer interaction was also evident on the end-walls that terminate the annular flowpath cross section. Cut-back end-walls, designed to reduce the boundary-layer growth upstream of the shock and minimize the interaction, also had negligible effect on the maximum contraction ratio. Both the excessive turning of low-momentum comer flows and local over-contraction due to asymmetric end-walls were identified as possible reasons for the discrepancy between the CFD predictions and the experiment. It is recommended that the centerbody spike and throat angles be reduced in order to lessen the induced pressure rise. The addition of a step on the cowl surface, and planar end-walls more closely approximating a plane of symmetry are also recommended. Provisions for end-wall boundary-layer bleed should be incorporated.
NASA Astrophysics Data System (ADS)
Bera, P.; Wędrychowicz, D.
2016-09-01
The article presents the influence of number and values of ratios in stepped gearbox on mileage fuel consumption in a city passenger car. The simulations were conducted for a particular vehicle characterized by its mass, body shape, size of tires and equipped with a combustion engine for which the characteristic of fuel consumption in dynamic states was already designated on the basis of engine test bed measurements. Several designs of transmission with different number of gears and their ratios were used in virtual simulations of road traffic, particularly in the NEDC test, to calculate mileage fuel consumption. This allows for a quantitative assessment of transmission parameters in terms of both vehicle economy and dynamic properties. Also, based on obtained results, recommendations for the selection of a particular vehicle for a specific type of exploitation have been formulated.
Creep-Fatigue Interaction and Cyclic Strain Analysis in P92 Steel Based on Test
NASA Astrophysics Data System (ADS)
Ji, Dongmei; Zhang, Lai-Chang; Ren, Jianxing; Wang, Dexian
2015-04-01
This work focused on the interaction of creep and fatigue and cyclic strain analysis in high-chromium ferritic P92 steel based on load-controlled creep-fatigue (CF) tests and conventional creep test at 873 K. Mechanical testing shows that the cyclic load inhibits the propagation of creep damage in the P92 steel and CF interaction becomes more severe with the decrease in the holding period duration and stress ratio. These results are also verified by the analysis of cyclic strain. The fatigue lifetime reduces with the increasing of the holding period duration and it does not reduce much with the increasing stress ratio especially under the conditions of long holding period duration. The cyclic strains (i.e., the strain range and creep strain) of CF tests consist of three stages, which is the same as those for the conventional creep behavior. The microscopic fracture surface observations illustrated that two different kinds of voids are observed at the fracture surfaces and Laves phase precipitates at the bottom of the voids.
de Krijger, Joep; Rans, Calvin; Van Hooreweder, Brecht; Lietaert, Karel; Pouran, Behdad; Zadpoor, Amir A
2017-06-01
Additively manufactured (AM) porous metallic biomaterials are considered promising candidates for bone substitution. In particular, AM porous titanium can be designed to exhibit mechanical properties similar to bone. There is some experimental data available in the literature regarding the fatigue behavior of AM porous titanium, but the effect of stress ratio on the fatigue behavior of those materials has not been studied before. In this paper, we study the effect of applied stress ratio on the compression-compression fatigue behavior of selective laser melted porous titanium (Ti-6Al-4V) based on the diamond unit cell. The porous titanium biomaterial is treated as a meta-material in the context of this work, meaning that R-ratios are calculated based on the applied stresses acting on a homogenized volume. After morphological characterization using micro computed tomography and quasi-static mechanical testing, the porous structures were tested under cyclic loading using five different stress ratios, i.e. R = 0.1, 0.3, 0.5, 0.7 and 0.8, to determine their S-N curves. Feature tracking algorithms were used for full-field deformation measurements during the fatigue tests. It was observed that the S-N curves of the porous structures shift upwards as the stress ratio increases. The stress amplitude was the most important factor determining the fatigue life. Constant fatigue life diagrams were constructed and compared with similar diagrams for bulk Ti-6Al-4V. Contrary to the bulk material, there was limited dependency of the constant life diagrams to mean stress. The notches present in the AM biomaterials were the sites of crack initiation. This observation and other evidence suggest that the notches created by the AM process cause the insensitivity of the fatigue life diagrams to mean stress. Feature tracking algorithms visualized the deformation during fatigue tests and demonstrated the root cause of inclined (45°) planes of specimen failure. In conclusion, the R-ratio behavior of AM porous biomaterials is both quantitatively and qualitatively different from that of bulk materials. Copyright © 2016 Elsevier Ltd. All rights reserved.
An Interactive Software for Conceptual Wing Flutter Analysis and Parametric Study
NASA Technical Reports Server (NTRS)
Mukhopadhyay, Vivek
1996-01-01
An interactive computer program was developed for wing flutter analysis in the conceptual design stage. The objective was to estimate the flutter instability boundary of a flexible cantilever wing, when well-defined structural and aerodynamic data are not available, and then study the effect of change in Mach number, dynamic pressure, torsional frequency, sweep, mass ratio, aspect ratio, taper ratio, center of gravity, and pitch inertia, to guide the development of the concept. The software was developed for Macintosh or IBM compatible personal computers, on MathCad application software with integrated documentation, graphics, data base and symbolic mathematics. The analysis method was based on non-dimensional parametric plots of two primary flutter parameters, namely Regier number and Flutter number, with normalization factors based on torsional stiffness, sweep, mass ratio, taper ratio, aspect ratio, center of gravity location and pitch inertia radius of gyration. The parametric plots were compiled in a Vought Corporation report from a vast data base of past experiments and wind-tunnel tests. The computer program was utilized for flutter analysis of the outer wing of a Blended-Wing-Body concept, proposed by McDonnell Douglas Corp. Using a set of assumed data, preliminary flutter boundary and flutter dynamic pressure variation with altitude, Mach number and torsional stiffness were determined.
Orbital Transfer Vehicle Engine Technology High Velocity Ratio Diffusing Crossover
NASA Technical Reports Server (NTRS)
Lariviere, Brian W.
1992-01-01
High speed, high efficiency head rise multistage pumps require continuous passage diffusing crossovers to effectively convey the pumped fluid from the exit of one impeller to the inlet of the next impeller. On Rocketdyne's Orbital Transfer Vehicle (OTV), the MK49-F, a three stage high pressure liquid hydrogen turbopump, utilizes a 6.23 velocity ratio diffusing crossover. This velocity ratio approaches the diffusion limits for stable and efficient flow over the operating conditions required by the OTV system. The design of the high velocity ratio diffusing crossover was based on advanced analytical techniques anchored by previous tests of stationary two-dimensional diffusers with steady flow. To secure the design and the analytical techniques, tests were required with the unsteady whirling characteristics produced by an impeller. A tester was designed and fabricated using a 2.85 times scale model of the MK49-F turbopumps first stage, including the inducer, impeller, and the diffusing crossover. Water and air tests were completed to evaluate the large scale turbulence, non-uniform velocity, and non-steady velocity on the pump and crossover head and efficiency. Suction performance tests from 80 percent to 124 percent of design flow were completed in water to assess these pump characteristics. Pump and diffuser performance from the water and air tests were compared with the actual MK49-F test data in liquid hydrogen.
The statistics of Pearce element diagrams and the Chayes closure problem
NASA Astrophysics Data System (ADS)
Nicholls, J.
1988-05-01
Pearce element ratios are defined as having a constituent in their denominator that is conserved in a system undergoing change. The presence of a conserved element in the denominator simplifies the statistics of such ratios and renders them subject to statistical tests, especially tests of significance of the correlation coefficient between Pearce element ratios. Pearce element ratio diagrams provide unambigous tests of petrologic hypotheses because they are based on the stoichiometry of rock-forming minerals. There are three ways to recognize a conserved element: 1. The petrologic behavior of the element can be used to select conserved ones. They are usually the incompatible elements. 2. The ratio of two conserved elements will be constant in a comagmatic suite. 3. An element ratio diagram that is not constructed with a conserved element in the denominator will have a trend with a near zero intercept. The last two criteria can be tested statistically. The significance of the slope, intercept and correlation coefficient can be tested by estimating the probability of obtaining the observed values from a random population of arrays. This population of arrays must satisfy two criteria: 1. The population must contain at least one array that has the means and variances of the array of analytical data for the rock suite. 2. Arrays with the means and variances of the data must not be so abundant in the population that nearly every array selected at random has the properties of the data. The population of random closed arrays can be obtained from a population of open arrays whose elements are randomly selected from probability distributions. The means and variances of these probability distributions are themselves selected from probability distributions which have means and variances equal to a hypothetical open array that would give the means and variances of the data on closure. This hypothetical open array is called the Chayes array. Alternatively, the population of random closed arrays can be drawn from the compositional space available to rock-forming processes. The minerals comprising the available space can be described with one additive component per mineral phase and a small number of exchange components. This space is called Thompson space. Statistics based on either space lead to the conclusion that Pearce element ratios are statistically valid and that Pearce element diagrams depict the processes that create chemical inhomogeneities in igneous rock suites.
Mitigation of corrosion attack on carbon steel coated cermet alloy in different anion contents
NASA Astrophysics Data System (ADS)
Khalid, Muhamad Azrin Mohd; Ismail, Azzura
2017-12-01
This research study evaluated the corrosion mechanism attack on carbon steel coated with cermet alloys (WC-9% Ni) in seawater at different sulphate-to-chloride ratios. The four different sulphate-to-chloride ratios were synthesised with the same seawater salinity of 3.5 % and same pH of real seawater. The corrosion tests involved immersion and electrochemical tests. The immersion test is used to determine the cermet coating ability to withstand the corrosion attack based on different ratios of anions present in the seawater at different periods of immersion. The corrosion attack was characterized by optical and Scanning Electron Microscopy (SEM). The aggressive anions present in the seawater influenced the corrosion attack on the cermet coating. For immersion test, results revealed that increasing sulphate more than chloride, increased the weight loss of cermets. The electrochemistry analysis showed that the passive layer forms on cermet coating prevented the material from further corrosion attack. However, due to its porosity, the passive layer collapsed and exposed the material for other corrosion reaction. For electrochemical test, the result shows that the solution with sulphate-to-chloride ratio of 0.14 (real seawater) has the highest corrosion current and Open Circuit Potential (OCP) compared to other solutions (different sulphate-to-chloride ratio). In conclusion, sulfate and chloride show their competition to attack the cermet coating on carbon steel and the higher the amount of chloride present in seawater, the higher the corrosion rate and pits formed on the cermet coating.
Lui, Kung-Jong
2012-05-01
When a new test with fewer invasions or less expenses to administer than the traditional test is developed, we may be interested in testing whether the former is non-inferior to the latter with respect to test accuracy. We define non-inferiority via both the odds ratio (OR) of correctly identifying a case and the OR of correctly identifying a non-case between two tests under comparison. We focus our discussion on testing the non-inferiority of a new screening test to a traditional screening test when a confirmatory procedure is performed only on patients with screen positives. On the basis of well-established methods for paired-sample data, we derive an asymptotic test procedure and an exact test procedure with respect to the two ORs defined here. Using Monte Carlo simulation, we evaluate the performance of these test procedures in a variety of situations. We note that the test procedures proposed here can also be applicable if we are interested in testing non-inferiority with respect to the ratio of sensitivities and the ratio of specificities. We discuss interval estimation of these ORs and sample size calculation based on the asymptotic test procedure considered here. We use the data taken from a study of the prostate-specific-antigen (PSA) test and the digital rectal examination (DRE) test to illustrate the practical use of these test procedures, interval estimators and sample size calculation formula. Copyright © 2012 Elsevier Inc. All rights reserved.
Planer, Katarina; Hagel, Anja
2018-01-01
A validity test was conducted to determine how care level–based nurse-to-resident ratios compare with actual daily care times per resident in Germany. Stability across different long-term care facilities was tested. Care level–based nurse-to-resident ratios were compared with the standard minimum nurse-to-resident ratios. Levels of care are determined by classification authorities in long-term care insurance programs and are used to distribute resources. Care levels are a powerful tool for classifying authorities in long-term care insurance. We used observer-based measurement of assignable direct and indirect care time in 68 nursing units for 2028 residents across 2 working days. Organizational data were collected at the end of the quarter in which the observation was made. Data were collected from January to March, 2012. We used a null multilevel model with random intercepts and multilevel models with fixed and random slopes to analyze data at both the organization and resident levels. A total of 14% of the variance in total care time per day was explained by membership in nursing units. The impact of care levels on care time differed significantly between nursing units. Forty percent of residents at the lowest care level received less than the standard minimum registered nursing time per day. For facilities that have been significantly disadvantaged in the current staffing system, a higher minimum standard will function more effectively than a complex classification system without scientific controls. PMID:29442533
Brühl, Albert; Planer, Katarina; Hagel, Anja
2018-01-01
A validity test was conducted to determine how care level-based nurse-to-resident ratios compare with actual daily care times per resident in Germany. Stability across different long-term care facilities was tested. Care level-based nurse-to-resident ratios were compared with the standard minimum nurse-to-resident ratios. Levels of care are determined by classification authorities in long-term care insurance programs and are used to distribute resources. Care levels are a powerful tool for classifying authorities in long-term care insurance. We used observer-based measurement of assignable direct and indirect care time in 68 nursing units for 2028 residents across 2 working days. Organizational data were collected at the end of the quarter in which the observation was made. Data were collected from January to March, 2012. We used a null multilevel model with random intercepts and multilevel models with fixed and random slopes to analyze data at both the organization and resident levels. A total of 14% of the variance in total care time per day was explained by membership in nursing units. The impact of care levels on care time differed significantly between nursing units. Forty percent of residents at the lowest care level received less than the standard minimum registered nursing time per day. For facilities that have been significantly disadvantaged in the current staffing system, a higher minimum standard will function more effectively than a complex classification system without scientific controls.
A Space Object Detection Algorithm using Fourier Domain Likelihood Ratio Test
NASA Astrophysics Data System (ADS)
Becker, D.; Cain, S.
Space object detection is of great importance in the highly dependent yet competitive and congested space domain. Detection algorithms employed play a crucial role in fulfilling the detection component in the situational awareness mission to detect, track, characterize and catalog unknown space objects. Many current space detection algorithms use a matched filter or a spatial correlator to make a detection decision at a single pixel point of a spatial image based on the assumption that the data follows a Gaussian distribution. This paper explores the potential for detection performance advantages when operating in the Fourier domain of long exposure images of small and/or dim space objects from ground based telescopes. A binary hypothesis test is developed based on the joint probability distribution function of the image under the hypothesis that an object is present and under the hypothesis that the image only contains background noise. The detection algorithm tests each pixel point of the Fourier transformed images to make the determination if an object is present based on the criteria threshold found in the likelihood ratio test. Using simulated data, the performance of the Fourier domain detection algorithm is compared to the current algorithm used in space situational awareness applications to evaluate its value.
A theoretically based determination of bowen-ratio fetch requirements
Stannard, D.I.
1997-01-01
Determination of fetch requirements for accurate Bowen-ratio measurements of latent- and sensible-heat fluxes is more involved than for eddy-correlation measurements because Bowen-ratio sensors are located at two heights, rather than just one. A simple solution to the diffusion equation is used to derive an expression for Bowen-ratio fetch requirements, downwind of a step change in surface fluxes. These requirements are then compared to eddy-correlation fetch requirements based on the same diffusion equation solution. When the eddy-correlation and upper Bowen-ratio sensor heights are equal, and the available energy upwind and downwind of the step change is constant, the Bowen-ratio method requires less fetch than does eddy correlation. Differences in fetch requirements between the two methods are greatest over relatively smooth surfaces. Bowen-ratio fetch can be reduced significantly by lowering the lower sensor, as well as the upper sensor. The Bowen-ratio fetch model was tested using data from a field experiment where multiple Bowen-ratio systems were deployed simultaneously at various fetches and heights above a field of bermudagrass. Initial comparisons were poor, but improved greatly when the model was modified (and operated numerically) to account for the large roughness of the upwind cotton field.
Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.
Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh
2015-01-01
Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.
Preliminary Base Pressures Obtained from the X-15 Airplane at Mach Numbers from 1.1 to 3.2
NASA Technical Reports Server (NTRS)
Saltzman, Edwin J.
1961-01-01
Base pressure measurements have been made on the fuselage, 10 deg.-wedge vertical fin, and side fairing of the X-15 airplane. Data are presented for Mach numbers between 1.1 and 3.2 for both powered and unpowered flight. Comparisons are made with data from small-scale-model tests, semiempirical estimates, and theory. The results of this preliminary study show that operation of the interim rocket engines (propellant flow rate approximately 70 lb/sec) reduces the base drag of the X-15 by 25 to 35 percent throughout the test Mach number range. Values of base drag coefficient for the side fairing and fuselage obtained from X-15 wind-tunnel models were adequate for predicting the overall full-scale performance of the test airplane. The leading-edge sweep of the upper movable vertical fin was not an important factor affecting the fin base pressure. The power-off base pressure coefficients of the upper movable vertical fin (a 10 deg. wedge with chord-to-thickness ratio of 5.5 and semispan-to-thickness ratio of 3.2) are in general agreement with the small-scale blunt-trailing-edge-wing data of several investigators and with two-dimensional theory.
The effect of thickness on fatigue crack propagation in 7475-T731 aluminum alloy sheet
NASA Technical Reports Server (NTRS)
Daiuto, R. A.; Hillberry, B. M.
1984-01-01
Tests were conducted on three thicknesses of 7475-T731 aluminum alloy sheet to investigate the effect of thickness on fatigue crack propagation under constant amplitude loading conditions and on retardation following a single peak overload. Constant amplitude loading tests were performed at stress ratios of 0.05 and 0.75 to obtain data for conditions with crack closure and without crack closure, respectively. At both stress ratios a thickness effect was clearly evident, with thicker specimens exhibiting higher growth rates in the transition from plane strain to plane stress region. The effect of thickness for a stress ratio of 0.05 corresponded well with the fracturing mode transitions observed on the specimens. A model based on the strain energy release rate which accounted for the fracture mode transition was found to correlate the thickness effects well. The specimens tested at the stress ratio of 0.75 did not make the transition from tensile mode to shear mode, indicating that another mechanism besides crack closure or fracture mode transition was active.
Infrared detectors and test technology of cryogenic camera
NASA Astrophysics Data System (ADS)
Yang, Xiaole; Liu, Xingxin; Xing, Mailing; Ling, Long
2016-10-01
Cryogenic camera which is widely used in deep space detection cools down optical system and support structure by cryogenic refrigeration technology, thereby improving the sensitivity. Discussing the characteristics and design points of infrared detector combined with camera's characteristics. At the same time, cryogenic background test systems of chip and detector assembly are established. Chip test system is based on variable cryogenic and multilayer Dewar, and assembly test system is based on target and background simulator in the thermal vacuum environment. The core of test is to establish cryogenic background. Non-uniformity, ratio of dead pixels and noise of test result are given finally. The establishment of test system supports for the design and calculation of infrared systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blau, Peter Julian; Jolly, Brian C
2009-01-01
The objective of this work was to support the development of grinding models for titanium metal-matrix composites (MMCs) by investigating possible relationships between their indentation hardness, low-stress belt abrasion, high-stress belt abrasion, and the surface grinding characteristics. Three Ti-based particulate composites were tested and compared with the popular titanium alloy Ti-6Al-4V. The three composites were a Ti-6Al-4V-based MMC with 5% TiB{sub 2} particles, a Ti-6Al-4V MMC with 10% TiC particles, and a Ti-6Al-4V/Ti-7.5%W binary alloy matrix that contained 7.5% TiC particles. Two types of belt abrasion tests were used: (a) a modified ASTM G164 low-stress loop abrasion test, and (b)more » a higher-stress test developed to quantify the grindability of ceramics. Results were correlated with G-ratios (ratio of stock removed to abrasives consumed) obtained from an instrumented surface grinder. Brinell hardness correlated better with abrasion characteristics than microindentation or scratch hardness. Wear volumes from low-stress and high-stress abrasive belt tests were related by a second-degree polynomial. Grindability numbers correlated with hard particle content but were also matrix-dependent.« less
Ramsay-Curve Differential Item Functioning
ERIC Educational Resources Information Center
Woods, Carol M.
2011-01-01
Differential item functioning (DIF) occurs when an item on a test, questionnaire, or interview has different measurement properties for one group of people versus another, irrespective of true group-mean differences on the constructs being measured. This article is focused on item response theory based likelihood ratio testing for DIF (IRT-LR or…
Analysis of micro-failure behaviors in artificial muscles based on fishing line and sewing thread
NASA Astrophysics Data System (ADS)
Xu, J. B.; Cheng, K. F.; Tu, S. L.; He, X. M.; Ma, C.; Jin, Y. Z.; Kang, X. N.; Sun, T.; Zhang, Y.
2017-06-01
The aim of the present study was to discuss a new and effective method for testing artificial muscles based on micro-failure behaviors analysis. Thermo-mechanical actuators based on fishing line and sewing thread, also, the capability of responding to ambient temperature variations producing a large amount of shrinkage ratio of a resulting variation in longitudinal length. The minimum micro-failure value is 0.02μm and the maximum value is 1.72μm with nylon twist pattern. The discovery of an innovative effective testing of artificial muscles based on polymeric fibers specimens on micro-failure, rupture, slippage, etc. This research finds out a micro-failure behavior analysis of thermo-mechanical actuators based on fishing line and sewing thread. The specimens show large deformations when heated together with warping performance in terms of shrinkage of energy and densities. With the purpose of providing useful analysis data for the further technology applications, we attempt micrometre-sized artificial muscles which were also tested was readily accessible and also can be applied to other polymeric fibers. Effective use of this technique achievement relies on rotate speed, temperature and tensile direction. The results of the tensile testing experiments were outstanding with respect to some important issues related to the response of micro-structure, twisted polymeric fibers and shrinkage ratio.
Parameter studies of sediments in the Storegga Slide region
NASA Astrophysics Data System (ADS)
Yang, S. L.; Kvalstad, T.; Solheim, A.; Forsberg, C. F.
2006-09-01
Based on classification tests, oedometer tests, fall-cone tests and triaxial tests, physical and mechanical properties of sediments in the Storegga Slide region were analysed to assess parameter interrelationships. The data show good relationships between a number of physical and mechanical parameters. Goodness of fit between compression index and various physical parameters can be improved by multiple regression analysis. The interclay void ratio and liquidity index correlate well with the undrained shear strength of clay. Sediments with higher water content, liquid limit, activity, interclay void ratio, plasticity index and liquidity index showed higher compression index and/or lower undrained shear strength. Some relationships between parameters were tested by using data from two other sites south of the Storegga Slide. A better understanding of properties of sediments in regions such as that of the Storegga Slide can be obtained through this approach.
NASA Technical Reports Server (NTRS)
Henning, Allen B.
1959-01-01
Two rocket-propelled missiles have been test flown by the Langley Pilotless Aircraft Research Division in order to study the stability characteristics of a body with six rectangular fins of very low aspect ratio. The fins, which had exposed aspect ratios of approximately o.o4 and 0.02 per fin, were mounted on bodies of fineness ratios of 12 and 18, respectively. Each body had a nose with a fineness ratio of 3.5 and a cylindrical afterbody. The body and the fin chord of the model having a fineness ratio of 12 were extended the length of 6 body diameters to produce the model with a fineness ratio of 18. The missiles were disturbed in flight by pulse rockets in order to obtain the stability data. The tests were performed over a Mach number range of 1.4 to 3.2 and a Reynolds number range of 2 x 10(exp 6) to 21 x l0(exp 6). The results of these tests indicate that these configurations with the long rectangular fins of very low aspect ratio showed little induced roll" with the missile of highest fineness ratio and longest fin chord exhibiting the least amount. Extending the body and fin chord of the shorter missile six body diameters and thereby increasing the fin area approximately 115 percent increased the lift-curve slope based on body cross-sectional area approximately 40 to 55 percent, increased the dynamic stability by a substantial amount, and increased the drag from 14 to 33 percent throughout the comparable Mach number range. The center-of-pressure location of both missiles remained constant over the Mach number range.
NASA Technical Reports Server (NTRS)
Smith, Timothy D.; Steffen, Christopher J., Jr.; Yungster, Shaye; Keller, Dennis J.
1998-01-01
The all rocket mode of operation is shown to be a critical factor in the overall performance of a rocket based combined cycle (RBCC) vehicle. An axisymmetric RBCC engine was used to determine specific impulse efficiency values based upon both full flow and gas generator configurations. Design of experiments methodology was used to construct a test matrix and multiple linear regression analysis was used to build parametric models. The main parameters investigated in this study were: rocket chamber pressure, rocket exit area ratio, injected secondary flow, mixer-ejector inlet area, mixer-ejector area ratio, and mixer-ejector length-to-inlet diameter ratio. A perfect gas computational fluid dynamics analysis, using both the Spalart-Allmaras and k-omega turbulence models, was performed with the NPARC code to obtain values of vacuum specific impulse. Results from the multiple linear regression analysis showed that for both the full flow and gas generator configurations increasing mixer-ejector area ratio and rocket area ratio increase performance, while increasing mixer-ejector inlet area ratio and mixer-ejector length-to-diameter ratio decrease performance. Increasing injected secondary flow increased performance for the gas generator analysis, but was not statistically significant for the full flow analysis. Chamber pressure was found to be not statistically significant.
Confidence bounds and hypothesis tests for normal distribution coefficients of variation
Steve P. Verrill; Richard A. Johnson
2007-01-01
For normally distributed populations, we obtain confidence bounds on a ratio of two coefficients of variation, provide a test for the equality of k coefficients of variation, and provide confidence bounds on a coefficient of variation shared by k populations. To develop these confidence bounds and test, we first establish that estimators based on Newton steps from n-...
ERIC Educational Resources Information Center
Immekus, Jason C.; Maller, Susan J.
2009-01-01
The Kaufman Adolescent and Adult Intelligence Test (KAIT[TM]) is an individually administered test of intelligence for individuals ranging in age from 11 to 85+ years. The item response theory-likelihood ratio procedure, based on the two-parameter logistic model, was used to detect differential item functioning (DIF) in the KAIT across males and…
Ali, Innocent M; Bigoga, Jude D; Forsah, Dorothy A; Cho-Ngwa, Fidelis; Tchinda, Vivian; Moor, Vicky Ama; Fogako, Josephine; Nyongalema, Philomena; Nkoa, Theresa; Same-Ekobo, Albert; Mbede, Joseph; Fondjo, Etienne; Mbacham, Wilfred F; Leke, Rose G F
2016-01-20
All suspected cases of malaria should receive a diagnostic test prior to treatment with artemisinin-based combinations based on the new WHO malaria treatment guidelines. This study compared the accuracy and some operational characteristics of 22 different immunochromatographic antigen capture point-of- malaria tests (RDTs) in Cameroon to inform test procurement prior to deployment of artemisinin-based combinations for malaria treatment. One hundred human blood samples (50 positive and 50 negative) collected from consenting febrile patients in two health centres at Yaoundé were used for evaluation of the 22 RDTs categorized as "Pf Only" (9) or "Pf + PAN" (13) based on parasite antigen captured [histidine rich protein II (HRP2) or lactate dehydrogenase (pLDH) or aldolase]. RDTs were coded to blind technicians performing the tests. The sensitivity, specificity, and predictive values of the positive and negative tests (PPV and NPV) as well as the likelihood ratios were assessed. The reliability and some operational characteristics were determined as the mean values from two assessors, and the Cohen's kappa statistic was then used to compare agreement. Light microscopy was the referent. Of all RDTs tested, 94.2 % (21/22) had sensitivity values greater than 90% among which 14 (63.6%) were 'Pf + PAN' RDTs. The specificity was generally lower than the sensitivity for all RDTs and poorer for "Pf Only" RDTs. The predictive values and likelihood ratios were better for non-HRP2 analytes for "Pf + PAN" RDTs. The Kappa value for most of the tests obtained was around 67% (95% CI 50-69%), corresponding to a moderate agreement. Overall, 94.2% (21/22) of RDTs tested had accuracy within the range recommended by the WHO, while one performed poorly, below acceptable levels. Seven "Pf + PAN" and 3 "Pf Only" RDTs were selected for further assessment based on performance characteristics. Harmonizing RDT test presentation and procedures would prevent mistakes of test performance and interpretation.
Posada, David
2006-01-01
ModelTest server is a web-based application for the selection of models of nucleotide substitution using the program ModelTest. The server takes as input a text file with likelihood scores for the set of candidate models. Models can be selected with hierarchical likelihood ratio tests, or with the Akaike or Bayesian information criteria. The output includes several statistics for the assessment of model selection uncertainty, for model averaging or to estimate the relative importance of model parameters. The server can be accessed at . PMID:16845102
Numerical Simulation of Selecting Model Scale of Cable in Wind Tunnel Test
NASA Astrophysics Data System (ADS)
Huang, Yifeng; Yang, Jixin
The numerical simulation method based on computational Fluid Dynamics (CFD) provides a possible alternative means of physical wind tunnel test. Firstly, the correctness of the numerical simulation method is validated by one certain example. In order to select the minimum length of the cable as to a certain diameter in the numerical wind tunnel tests, the numerical wind tunnel tests based on CFD are carried out on the cables with several different length-diameter ratios (L/D). The results show that, when the L/D reaches to 18, the drag coefficient is stable essentially.
Demirel, Adnan; Baykara, Murat; Koca, Tuba Tülay; Berk, Ejder
2018-06-01
Ultrasound elastography (UE) is a new ultrasound-based imaging technique that provides information about elasticity and stiffness of tissues. This cross-sectional study aimed to identify the diagnostic importance of UE in supraspinatus impingement syndrome. Forty-one subjects, aged 38-70 years, were included in the study. UE was used to determine the elasticity of the supraspinatus muscle. The strain ratio was calculated as the evaluation criteria to measure the elasticity of the muscle. High strain ratio indicated low elasticity. The measurements were made by the blinded radiologist while the patients sat with their shoulder in a neutral position. The diagnostic value of the strain ratio was evaluated using the receiver operating characteristic (ROC) analysis. The mean strain value of the supraspinatus muscle on the intact and pathological shoulders determined by UE was 0.74 ± 0.33 and 0.31 ± 0.24, respectively. A low strain ratio value in the supraspinatus muscle on the side with impingement syndrome was measured. When the test variable was evaluated as "strain ratio" according to ROC curve analysis, it was found to be above the reference line [0.849 (> 0.5)] (P = 0.00). When the cutoff value was selected as 0.495, the sensitivity and specificity were found to be 75.6 and 78% (the strain ratio value > 0.495), respectively. Measurement of strain ratio with UE can be used as a noninvasive, inexpensive, and practical diagnostic test for the shoulder impingement disease.
Pinder, John E; Rowan, David J; Rasmussen, Joseph B; Smith, Jim T; Hinton, Thomas G; Whicker, F W
2014-08-01
Data from published studies and World Wide Web sources were combined to produce and test a regression model to predict Cs concentration ratios for freshwater fish species. The accuracies of predicted concentration ratios, which were computed using 1) species trophic levels obtained from random resampling of known food items and 2) K concentrations in the water for 207 fish from 44 species and 43 locations, were tested against independent observations of ratios for 57 fish from 17 species from 25 locations. Accuracy was assessed as the percent of observed to predicted ratios within factors of 2 or 3. Conservatism, expressed as the lack of under prediction, was assessed as the percent of observed to predicted ratios that were less than 2 or less than 3. The model's median observed to predicted ratio was 1.26, which was not significantly different from 1, and 50% of the ratios were between 0.73 and 1.85. The percentages of ratios within factors of 2 or 3 were 67 and 82%, respectively. The percentages of ratios that were <2 or <3 were 79 and 88%, respectively. An example for Perca fluviatilis demonstrated that increased prediction accuracy could be obtained when more detailed knowledge of diet was available to estimate trophic level. Copyright © 2014 Elsevier Ltd. All rights reserved.
Modeling of Micro Deval abrasion loss based on some rock properties
NASA Astrophysics Data System (ADS)
Capik, Mehmet; Yilmaz, Ali Osman
2017-10-01
Aggregate is one of the most widely used construction material. The quality of the aggregate is determined using some testing methods. Among these methods, the Micro Deval Abrasion Loss (MDAL) test is commonly used for the determination of the quality and the abrasion resistance of aggregate. The main objective of this study is to develop models for the prediction of MDAL from rock properties, including uniaxial compressive strength, Brazilian tensile strength, point load index, Schmidt rebound hardness, apparent porosity, void ratio Cerchar abrasivity index and Bohme abrasion test are examined. Additionally, the MDAL is modeled using simple regression analysis and multiple linear regression analysis based on the rock properties. The study shows that the MDAL decreases with the increase of uniaxial compressive strength, Brazilian tensile strength, point load index, Schmidt rebound hardness and Cerchar abrasivity index. It is also concluded that the MDAL increases with the increase of apparent porosity, void ratio and Bohme abrasion test. The modeling results show that the models based on Bohme abrasion test and L type Schmidt rebound hardness give the better forecasting performances for the MDAL. More models, including the uniaxial compressive strength, the apparent porosity and Cerchar abrasivity index, are developed for the rapid estimation of the MDAL of the rocks. The developed models were verified by statistical tests. Additionally, it can be stated that the proposed models can be used as a forecasting for aggregate quality.
Signorelli, Heather; Straseski, Joely A; Genzen, Jonathan R; Walker, Brandon S; Jackson, Brian R; Schmidt, Robert L
2015-01-01
Appropriate test utilization is usually evaluated by adherence to published guidelines. In many cases, medical guidelines are not available. Benchmarking has been proposed as a method to identify practice variations that may represent inappropriate testing. This study investigated the use of benchmarking to identify sites with inappropriate utilization of testing for a particular analyte. We used a Web-based survey to compare 2 measures of vitamin D utilization: overall testing intensity (ratio of total vitamin D orders to blood-count orders) and relative testing intensity (ratio of 1,25(OH)2D to 25(OH)D test orders). A total of 81 facilities contributed data. The average overall testing intensity index was 0.165, or approximately 1 vitamin D test for every 6 blood-count tests. The average relative testing intensity index was 0.055, or one 1,25(OH)2D test for every 18 of the 25(OH)D tests. Both indexes varied considerably. Benchmarking can be used as a screening tool to identify outliers that may be associated with inappropriate test utilization. Copyright© by the American Society for Clinical Pathology (ASCP).
NASA Technical Reports Server (NTRS)
Hwang, Kyu C.; Tiwari, Surrendra N.; Miley, Stanley J.
1995-01-01
In recent years, active research has been conducted to study the technological feasibility of supersonic laminar flow control on the wing of the High Speed Civil Transport (HSCT). For this study, the F-16XL has been chosen due to its highly swept crank wing planform that closely resembles the HSCT configurations. During flights, it is discovered that the shock wave generated from the aircraft inlet introduces disturbances on the wing where the data acquisition is conducted. The flow field about a supersonic inlet is characterized by a complex three dimensional pattern of shock waves generated by the geometrical configuration of a deflector and a cowl lip. Hence, in this study, experimental method is employed to investigate the effects of the variation of deflector configuration on the flow field, and consequently, the possibility of diverting the incoming shock-disturbances away from the test section. In the present experiments, a model composed of a simple circular tube with a triangular deflector is designed to study the deflector length and the deflector base width variation in the flow field. Experimental results indicate that the lowest external pressure ratio is observed at the junction where the deflector lip and the inlet cowl lip merge. Also, it is noted that the external pressure ratio, the internal pressure ratio, the coefficient of spillage drag, and the shock standoff distance decrease as the deflector length increases. In addition, the Redefined Total Pressure Recovery Ratio (RTPRR) increases with an increase in the deflector length. Results from the study of the effect of the deflector's base width variation on the flow field indicate that the lowest external pressure ratio is observed at the junction between the inlet cowl lip and the deflector lip. As the base width of the deflector increases, the external pressure ratio at 0 rotation increases, whereas the external pressure ratio at 180 rotation decreases. In addition, the internal pressure ratio and the coefficient of spillage drag decrease as the base width of the deflector increases. However, RTPRR and shock standoff distance increase as the base width increases. In conclusion, as deflector dimensions vary, distinctive patterns in the pressure variation around the inlet deflector are observed. With an increase in the deflector length and base width, the magnitude of shock-disturbances are weakened due to a decrease in the external pressure ratio. Also, as the deflector length and base width increase, a smaller bow shock angle is formed. Therefore, the inlet shock wave formation would be significantly altered, and consequently, shock disturbances on the wing test section can be avoided through appropriately designing the deflector.
Klinck, Holger; Mellinger, David K
2011-04-01
The energy ratio mapping algorithm (ERMA) was developed to improve the performance of energy-based detection of odontocete echolocation clicks, especially for application in environments with limited computational power and energy such as acoustic gliders. ERMA systematically evaluates many frequency bands for energy ratio-based detection of echolocation clicks produced by a target species in the presence of the species mix in a given geographic area. To evaluate the performance of ERMA, a Teager-Kaiser energy operator was applied to the series of energy ratios as derived by ERMA. A noise-adaptive threshold was then applied to the Teager-Kaiser function to identify clicks in data sets. The method was tested for detecting clicks of Blainville's beaked whales while rejecting echolocation clicks of Risso's dolphins and pilot whales. Results showed that the ERMA-based detector correctly identified 81.6% of the beaked whale clicks in an extended evaluation data set. Average false-positive detection rate was 6.3% (3.4% for Risso's dolphins and 2.9% for pilot whales).
Sequential Probability Ratio Test for Collision Avoidance Maneuver Decisions
NASA Technical Reports Server (NTRS)
Carpenter, J. Russell; Markley, F. Landis
2010-01-01
When facing a conjunction between space objects, decision makers must chose whether to maneuver for collision avoidance or not. We apply a well-known decision procedure, the sequential probability ratio test, to this problem. We propose two approaches to the problem solution, one based on a frequentist method, and the other on a Bayesian method. The frequentist method does not require any prior knowledge concerning the conjunction, while the Bayesian method assumes knowledge of prior probability densities. Our results show that both methods achieve desired missed detection rates, but the frequentist method's false alarm performance is inferior to the Bayesian method's
Accurate masking technology for high-resolution powder blasting
NASA Astrophysics Data System (ADS)
Pawlowski, Anne-Gabrielle; Sayah, Abdeljalil; Gijs, Martin A. M.
2005-07-01
We have combined eroding 10 µm diameter Al2O3 particles with a new masking technology to realize the smallest and most accurate possible structures by powder blasting. Our masking technology is based on the sequential combination of two polymers:(i) the brittle epoxy resin SU8 for its photosensitivity and (ii) the elastic and thermocurable poly-dimethylsiloxane for its large erosion resistance. We have micropatterned various types of structures with a minimum width of 20 µm for test structures with an aspect ratio of 1, and 50 µm for test structures with an aspect ratio of 2.
NASA Astrophysics Data System (ADS)
Abbasi, R. U.; Abu-Zayyad, T.; Amann, J. F.; Archbold, G.; Atkins, R.; Bellido, J. A.; Belov, K.; Belz, J. W.; Ben-Zvi, S. Y.; Bergman, D. R.; Boyer, J. H.; Burt, G. W.; Cao, Z.; Clay, R. W.; Connolly, B. M.; Dawson, B. R.; Deng, W.; Farrar, G. R.; Fedorova, Y.; Findlay, J.; Finley, C. B.; Hanlon, W. F.; Hoffman, C. M.; Holzscheiter, M. H.; Hughes, G. A.; Hüntemeyer, P.; Jui, C. C. H.; Kim, K.; Kirn, M. A.; Knapp, B. C.; Loh, E. C.; Maestas, M. M.; Manago, N.; Mannel, E. J.; Marek, L. J.; Martens, K.; Matthews, J. A. J.; Matthews, J. N.; O'Neill, A.; Painter, C. A.; Perera, L.; Reil, K.; Riehle, R.; Roberts, M. D.; Sasaki, M.; Schnetzer, S. R.; Seman, M.; Simpson, K. M.; Sinnis, G.; Smith, J. D.; Snow, R.; Sokolsky, P.; Song, C.; Springer, R. W.; Stokes, B. T.; Thomas, J. R.; Thomas, S. B.; Thomson, G. B.; Tupa, D.; Westerhoff, S.; Wiencke, L. R.; Zech, A.
2005-04-01
We present the results of a search for cosmic-ray point sources at energies in excess of 4.0×1019 eV in the combined data sets recorded by the Akeno Giant Air Shower Array and High Resolution Fly's Eye stereo experiments. The analysis is based on a maximum likelihood ratio test using the probability density function for each event rather than requiring an a priori choice of a fixed angular bin size. No statistically significant clustering of events consistent with a point source is found.
Duivenvoorde, Loes P. M.; van Schothorst, Evert M.; Swarts, Hans M.; Kuda, Ondrej; Steenbergh, Esther; Termeulen, Sander; Kopecky, Jan; Keijer, Jaap
2015-01-01
Poly-unsaturated fatty acids (PUFAs) are considered to be healthier than saturated fatty acids (SFAs), but others postulate that especially the ratio of omega-6 to omega-3 PUFAs (n6/n3 ratio) determines health. Health can be determined with biomarkers, but functional health status is likely better reflected by challenge tests that assess metabolic flexibility. The aim of this study was to determine the effect of high-fat diets with different fatty acid compositions, but similar n6/n3 ratio, on metabolic flexibility. Therefore, adult male mice received isocaloric high-fat diets with either predominantly PUFAs (HFpu diet) or predominantly SFAs (HFs diet) but similar n6/n3 ratio for six months, during and after which several biomarkers for health were measured. Metabolic flexibility was assessed by the response to an oral glucose tolerance test, a fasting and re-feeding test and an oxygen restriction test (OxR; normobaric hypoxia). The latter two are non-invasive, indirect calorimetry-based tests that measure the adaptive capacity of the body as a whole. We found that the HFs diet, compared to the HFpu diet, increased mean adipocyte size, liver damage, and ectopic lipid storage in liver and muscle; although, we did not find differences in body weight, total adiposity, adipose tissue health, serum adipokines, whole body energy balance, or circadian rhythm between HFs and HFpu mice. HFs mice were, furthermore, less flexible in their response to both fasting- re-feeding and OxR, while glucose tolerance was indistinguishable. To conclude, the HFs versus the HFpu diet increased ectopic fat storage, liver damage, and mean adipocyte size and reduced metabolic flexibility in male mice. This study underscores the physiological relevance of indirect calorimetry-based challenge tests. PMID:26098756
Using effort information with change-in-ratio data for population estimation
Udevitz, Mark S.; Pollock, Kenneth H.
1995-01-01
Most change-in-ratio (CIR) methods for estimating fish and wildlife population sizes have been based only on assumptions about how encounter probabilities vary among population subclasses. When information on sampling effort is available, it is also possible to derive CIR estimators based on assumptions about how encounter probabilities vary over time. This paper presents a generalization of previous CIR models that allows explicit consideration of a range of assumptions about the variation of encounter probabilities among subclasses and over time. Explicit estimators are derived under this model for specific sets of assumptions about the encounter probabilities. Numerical methods are presented for obtaining estimators under the full range of possible assumptions. Likelihood ratio tests for these assumptions are described. Emphasis is on obtaining estimators based on assumptions about variation of encounter probabilities over time.
NASA Technical Reports Server (NTRS)
Lucas, J. N.; Deng, W.; Oram, S. W.; Hill, F. S.; Durante, M.; George, K.; Wu, H.; Owens, C. L.; Yang, T.
1999-01-01
In the present study, F ratios for both stable chromosome aberrations, i.e. ratios of translocations to pericentric inversions, and unstable aberrations, i.e. dicentrics and centric rings, were measured using fluorescence in situ hybridization. F ratios for stable aberrations measured after exposure to low (2.89 Gy 60Co gamma rays) and high-LET (0.25 Gy 56Fe ions; 1.25 Gy 56Fe ions; 3.0 Gy 12C ions) radiation were 6.5 +/- 1.5, 4.7 +/- 1.6, 9.3 +/- 2.5 and 10.4 +/- 3.0, respectively. F ratios for unstable aberrations measured after low (2.89 Gy 60Co gamma rays) and high-LET (0.25 Gy 56Fe ions; 3.0 Gy 12C ions) radiations were 6.5 +/- 1.6, 6.3 +/- 2.3 and 11.1 +/- 3.7, respectively. No significant difference between the F ratios for low- and high-LET radiation was found. Further tests on the models for calculation of the F ratio proposed by Brenner and Sachs (Radiat. Res. 140, 134-142, 1994) showed that the F ratio may not be straightforward as a practical fingerprint for densely ionizing radiation.
NASA Technical Reports Server (NTRS)
Chapman, Dean R; Perkins, Edward W
1951-01-01
Models were tested to evaluate effects of Reynolds number for both laminar and turbulent boundary layers. Principal geometric variables investigated were afterbody shape and length-diameter ratio. Force tests and base-pressure measurements were made. Schlieren photographs were used to analyze the effects of viscosity on flow separation and shock-wave configuration and to verify the condition of the boundary layer as deduced from the force tests. The results are discussed and compared with theoretical calculations.
Cost-effectiveness of one-time genetic testing to minimize lifetime adverse drug reactions.
Alagoz, O; Durham, D; Kasirajan, K
2016-04-01
We evaluated the cost-effectiveness of one-time pharmacogenomic testing for preventing adverse drug reactions (ADRs) over a patient's lifetime. We developed a Markov-based Monte Carlo microsimulation model to represent the ADR events in the lifetime of each patient. The base-case considered a 40-year-old patient. We measured health outcomes in life years (LYs) and quality-adjusted LYs (QALYs) and estimated costs using 2013 US$. In the base-case, one-time genetic testing had an incremental cost-effectiveness ratio (ICER) of $43,165 (95% confidence interval (CI) is ($42,769,$43,561)) per additional LY and $53,680 per additional QALY (95% CI is ($53,182,$54,179)), hence under the base-case one-time genetic testing is cost-effective. The ICER values were most sensitive to the average probability of death due to ADR, reduction in ADR rate due to genetic testing, mean ADR rate and cost of genetic testing.
The adjusting factor method for weight-scaling truckloads of mixed hardwood sawlogs
Edward L. Adams
1976-01-01
A new method of weight-scaling truckloads of mixed hardwood sawlogs systematically adjusts for changes in the weight/volume ratio of logs coming into a sawmill. It uses a conversion factor based on the running average of weight/volume ratios of randomly selected sample loads. A test of the method indicated that over a period of time the weight-scaled volume should...
Descatha, A; Dale, A-M; Franzblau, A; Coomes, J; Evanoff, B
2010-02-01
We evaluated the utility of physical examination manoeuvres in the prediction of carpal tunnel syndrome (CTS) in a population-based research study. We studied a cohort of 1108 newly employed workers in several industries. Each worker completed a symptom questionnaire, a structured physical examination and nerve conduction study. For each hand, our CTS case definition required both median nerve conduction abnormality and symptoms classified as "classic" or "probable" on a hand diagram. We calculated the positive predictive values and likelihood ratios for physical examination manoeuvres in subjects with and without symptoms. The prevalence of CTS in our cohort was 1.2% for the right hand and 1.0% for the left hand. The likelihood ratios of a positive test for physical provocative tests ranged from 2.0 to 3.3, and those of a negative test from 0.3 to 0.9. The post-test probability of positive testing was <50% for all strategies tested. Our study found that physical examination, alone or in combination with symptoms, was not predictive of CTS in a working population. We suggest using specific symptoms as a first-level screening tool, and nerve conduction study as a confirmatory test, as a case definition strategy in research settings.
Lee, Jae Min; Lee, Hong Sik; Hyun, Jong Jin; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Chun, Hoon Jai; Um, Soon Ho; Kim, Chang Duck
2016-07-15
To evaluate the value of systemic inflammation-based markers as prognostic factors for advanced pancreatic cancer (PC). Data from 82 patients who underwent combination chemotherapy with gemcitabine and erlotinib for PC from 2011 to 2014 were collected retrospectively. Data that included the neutrophil-to-lymphocyte ratio (NLR), the platelet-to-lymphocyte ratio, and the C-reactive protein (CRP)-to-albumin (CRP/Alb) ratio were analyzed. Kaplan-Meier curves, and univariate and multivariate Cox proportional hazards regression analyses were used to identify the prognostic factors associated with progression-free survival (PFS) and overall survival (OS). The univariate analysis demonstrated the prognostic value of the NLR (P = 0.049) and the CRP/Alb ratio (P = 0.047) in relation to PFS, and a positive relationship between an increase in inflammation-based markers and a poor prognosis in relation to OS. The multivariate analysis determined that an increased NLR (hazard ratio = 2.76, 95%CI: 1.33-5.75, P = 0.007) is an independent prognostic factor for poor OS. There was no association between the PLR and the patients' prognoses in those who had received chemotherapy that comprised gemcitabine and erlotinib in combination. The Kaplan-Meier method and the log-rank test determined significantly worse outcomes in relation to PFS and OS in patients with an NLR > 5 or a CRP/Alb ratio > 5. Systemic inflammation-based markers, including increases in the NLR and the CRP/Alb ratio, may be useful for predicting PC prognoses.
Valine needs in starting and growing Cobb (500) broilers.
Tavernari, F C; Lelis, G R; Vieira, R A; Rostagno, H S; Albino, L F T; Oliveira Neto, A R
2013-01-01
Two independent experiments were conducted with male Cobb × Cobb 500 broilers to determine the optimal valine-to-digestible-lysine ratio for broiler development. We conducted a randomized block experiment with 7 treatments, each with 8 replicates of 25 starter birds (8 to 21 d of age) and 20 finisher (30 to 43 d of age) birds. To prevent any excess of digestible lysine, 93% of the recommended level of digestible lysine was used to evaluate the valine-to-lysine ratio. The utilized levels of dietary digestible lysine were 10.7 and 9.40 g/kg for the starting and growing phases, respectively. A control diet with 100% of the recommended level of lysine and an adequate valine-to-lysine ratio was also used. The feed intake, weight gain, feed conversion ratio, and carcass parameters were evaluated. The treatments had no significant effect on the feed intakes or carcass parameters in the starter and finisher phases. However, during both of the studied phases, we observed a quadratic effect on weight gain and the feed conversion ratio. The broilers of both phases that were fed test diets with the lower valine-to-lysine (Val/Lys) ratio had poorer performance compared with those broilers fed control diets. However, when higher Val/Lys ratios were used for the starting and growing broilers that were fed test diets, the 2 groups had similar performance. During the starting phase, in broilers that were fed a higher Val/Lys ratio, weight gain, and the feed conversion ratio improved by 5.5% compared with broilers fed the basal diets. The broilers in the growing phase also had improved performance (by 7 to 8%) when the test diets had higher Val/Lys ratios. Based on the analysis of the starter phase data, we concluded that the optimal digestible Val/Lys ratio for Cobb × Cobb 500 broilers is 77%, whereas for birds in the finisher phase (30 to 43 d of age), a digestible Val/Lys ratio of 76% is suggested.
The Risk of Adverse Impact in Selections Based on a Test with Known Effect Size
ERIC Educational Resources Information Center
De Corte, Wilfried; Lievens, Filip
2005-01-01
The authors derive the exact sampling distribution function of the adverse impact (AI) ratio for single-stage, top-down selections using tests with known effect sizes. Subsequently, it is shown how this distribution function can be used to determine the risk that a future selection decision on the basis of such tests will result in an outcome that…
Isometric shoulder strength in young swimmers.
McLaine, Sally J; Ginn, Karen A; Fell, James W; Bird, Marie-Louise
2018-01-01
The prevalence of shoulder pain in young swimmers is high. Shoulder rotation strength and the ratio of internal to external rotation strength have been reported as potential modifiable risk factors associated with shoulder pain. However, relative strength measures in elevated positions, which include flexion and extension, have not been established for the young swimmer. The aim of this study was to establish clinically useful, normative shoulder strength measures and ratios for swimmers (14-20 years) without shoulder pain. Cross-sectional, observational study. Swimmers (N=85) without a recent history of shoulder pain underwent strength testing of shoulder flexion and extension (in 140° abduction); and internal and external rotation (in 90° abduction). Strength tests were performed in supine using a hand-held dynamometer and values normalised to body weight. Descriptive statistics were calculated for strength and strength ratios (flexion:extension and internal:external rotation). Differences between groups (based on gender, history of pain, test and arm dominance) were explored using independent and paired t tests. Normative shoulder strength values and ratios were established for young swimmers. There was a significant difference (p<0.002) in relative strength between males and females for all tests with no differences in strength ratios. Relative strength of the dominant and non-dominant shoulders (except for extension); and for swimmers with and without a history of shoulder pain was not significantly different. A normal shoulder strength profile for the young swimmer has been established which provides a valuable reference for the clinician assessing shoulder strength in this population. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Using permutations to detect dependence between time series
NASA Astrophysics Data System (ADS)
Cánovas, Jose S.; Guillamón, Antonio; Ruíz, María del Carmen
2011-07-01
In this paper, we propose an independence test between two time series which is based on permutations. The proposed test can be carried out by means of different common statistics such as Pearson’s chi-square or the likelihood ratio. We also point out why an exact test is necessary. Simulated and real data (return exchange rates between several currencies) reveal the capacity of this test to detect linear and nonlinear dependences.
Dorizzi, R M; Maconi, M; Giavarina, D; Loza, G; Aman, M; Moreira, J; Bisoffi, Z; Gennuso, C
2009-10-01
The adoption of Evidence Based Laboratory Medicine (EBLM) has been hampered until today by the lack of effective tools. The SIMeL EBLM e-Thesaurus (on-line Repertoire of the diagnostic effectiveness of the laboratory, radiology and cardiology test) provides a useful support to clinical laboratory professionals and to clinicians for the interpretation of the diagnostic tests. The e-Thesaurus is an application developed using Microsoft Active Server Pages technology and carried out with Web Server Microsoft Internet Information Server and is available at the SIMeL website using a browser running JavaScript scripts (Internet Explorer is recommended). It contains a database (in Italian, English and Spanish) of the sensitivity and specificity (including the 95% confidence interval), the positive and negative likelihood ratios, the Diagnostic Odds Ratio and the Number Needed to Diagnose of more than 2000 diagnostic (most laboratory but also cardiology and radiology) tests. The e-Thesaurus improves the previous SIMeL paper and CD Thesaurus; its main features are a three languages search and a continuous and an easy updating capability.
Quantitative Sensory Testing Predicts Pregabalin Efficacy in Painful Chronic Pancreatitis
Olesen, Søren S.; Graversen, Carina; Bouwense, Stefan A. W.; van Goor, Harry; Wilder-Smith, Oliver H. G.; Drewes, Asbjørn M.
2013-01-01
Background A major problem in pain medicine is the lack of knowledge about which treatment suits a specific patient. We tested the ability of quantitative sensory testing to predict the analgesic effect of pregabalin and placebo in patients with chronic pancreatitis. Methods Sixty-four patients with painful chronic pancreatitis received pregabalin (150–300 mg BID) or matching placebo for three consecutive weeks. Analgesic effect was documented in a pain diary based on a visual analogue scale. Responders were defined as patients with a reduction in clinical pain score of 30% or more after three weeks of study treatment compared to baseline recordings. Prior to study medication, pain thresholds to electric skin and pressure stimulation were measured in dermatomes T10 (pancreatic area) and C5 (control area). To eliminate inter-subject differences in absolute pain thresholds an index of sensitivity between stimulation areas was determined (ratio of pain detection thresholds in pancreatic versus control area, ePDT ratio). Pain modulation was recorded by a conditioned pain modulation paradigm. A support vector machine was used to screen sensory parameters for their predictive power of pregabalin efficacy. Results The pregabalin responders group was hypersensitive to electric tetanic stimulation of the pancreatic area (ePDT ratio 1.2 (0.9–1.3)) compared to non-responders group (ePDT ratio: 1.6 (1.5–2.0)) (P = 0.001). The electrical pain detection ratio was predictive for pregabalin effect with a classification accuracy of 83.9% (P = 0.007). The corresponding sensitivity was 87.5% and specificity was 80.0%. No other parameters were predictive of pregabalin or placebo efficacy. Conclusions The present study provides first evidence that quantitative sensory testing predicts the analgesic effect of pregabalin in patients with painful chronic pancreatitis. The method can be used to tailor pain medication based on patient’s individual sensory profile and thus comprises a significant step towards personalized pain medicine. PMID:23469256
Zhang, Luqing; Yang, Duoxing; Braun, Anika; Han, Zhenhua
2017-01-01
Granite is a typical crystalline material, often used as a building material, but also a candidate host rock for the repository of high-level radioactive waste. The petrographic texture—including mineral constituents, grain shape, size, and distribution—controls the fracture initiation, propagation, and coalescence within granitic rocks. In this paper, experimental laboratory tests and numerical simulations of a grain-based approach in two-dimensional Particle Flow Code (PFC2D) were conducted on the mechanical strength and failure behavior of Alashan granite, in which the grain-like structure of granitic rock was considered. The microparameters for simulating Alashan granite were calibrated based on real laboratory strength values and strain-stress curves. The unconfined uniaxial compressive test and Brazilian indirect tensile test were performed using a grain-based approach to examine and discuss the influence of mineral grain size and distribution on the strength and patterns of microcracks in granitic rocks. The results show it is possible to reproduce the uniaxial compressive strength (UCS) and uniaxial tensile strength (UTS) of Alashan granite using the grain-based approach in PFC2D, and the average mineral size has a positive relationship with the UCS and UTS. During the modeling, most of the generated microcracks were tensile cracks. Moreover, the ratio of the different types of generated microcracks is related to the average grain size. When the average grain size in numerical models is increased, the ratio of the number of intragrain tensile cracks to the number of intergrain tensile cracks increases, and the UCS of rock samples also increases with this ratio. However, the variation in grain size distribution does not have a significant influence on the likelihood of generated microcracks. PMID:28773201
Zhou, Jian; Zhang, Luqing; Yang, Duoxing; Braun, Anika; Han, Zhenhua
2017-07-21
Granite is a typical crystalline material, often used as a building material, but also a candidate host rock for the repository of high-level radioactive waste. The petrographic texture-including mineral constituents, grain shape, size, and distribution-controls the fracture initiation, propagation, and coalescence within granitic rocks. In this paper, experimental laboratory tests and numerical simulations of a grain-based approach in two-dimensional Particle Flow Code (PFC2D) were conducted on the mechanical strength and failure behavior of Alashan granite, in which the grain-like structure of granitic rock was considered. The microparameters for simulating Alashan granite were calibrated based on real laboratory strength values and strain-stress curves. The unconfined uniaxial compressive test and Brazilian indirect tensile test were performed using a grain-based approach to examine and discuss the influence of mineral grain size and distribution on the strength and patterns of microcracks in granitic rocks. The results show it is possible to reproduce the uniaxial compressive strength (UCS) and uniaxial tensile strength (UTS) of Alashan granite using the grain-based approach in PFC2D, and the average mineral size has a positive relationship with the UCS and UTS. During the modeling, most of the generated microcracks were tensile cracks. Moreover, the ratio of the different types of generated microcracks is related to the average grain size. When the average grain size in numerical models is increased, the ratio of the number of intragrain tensile cracks to the number of intergrain tensile cracks increases, and the UCS of rock samples also increases with this ratio. However, the variation in grain size distribution does not have a significant influence on the likelihood of generated microcracks.
Sun, Yazhen; Fang, Chenze; Wang, Jinchang; Yuan, Xuezhong; Fan, Dong
2018-05-03
Laboratory predictions for the fatigue life of an asphalt mixture under cyclic loading based on the plateau value (PV) of the permanent deformation ratio (PDR) were carried out by three-point bending fatigue tests. The influence of test conditions on the recovery ratio of elastic deformation (RRED), the permanent deformation (PD) and PDR, and the trends of RRED, PD, and PDR were studied. The damage variable was defined by using PDR, and the relation of the fatigue life to PDR was determined by analyzing the damage evolution process. The fatigue equation was established based on the PV of PDR and the fatigue life was predicted by analyzing the relation of the fatigue life to the PV. The results show that the RRED decreases with the increase of the number of loading cycles, and the elastic recovery ability of the asphalt mixture gradually decreases. The two mathematical models proposed are based on the change laws of the RRED, and the PD can well describe the change laws. The RRED or the PD cannot well predict the fatigue life because they do not change monotonously with the fatigue life, and one part of the deformation causes the damage and the other part causes the viscoelastic deformation. The fatigue life decreases with the increase of the PDR. The average PDR in the second stage is taken as the PV, and the fatigue life decreases in a power law with the increase of the PV. The average relative error of the fatigue life predicted by the fatigue equation to the test fatigue life is 5.77%. The fatigue equation based on PV can well predict the fatigue life.
Influence of ceramic dental crown coating substrate thickness ratio on strain energy release rate
NASA Astrophysics Data System (ADS)
Khasnulhadi, K.; Daud, R.; Mat, F.; Noor, S. N. F. M.; Basaruddin, K. S.; Sulaiman, M. H.
2017-10-01
This paper presents the analysis of coating substrate thickness ratio effect on the crown coating fracture behaviour. The bi-layer material is examined under four point bending with pre-crack at the bottom of the core material by using finite element. Three different coating thickness of core/substrate was tested which is 1:1, 1:2 and 2:1. The fracture parameters are analysed based on bilayer and homogenous elastic interaction. The result shows that the ratio thickness of core/veneer provided a significant effect on energy release rate.
Evaluation of AISI 4140 Steel Repair Without Post-Weld Heat Treatment
NASA Astrophysics Data System (ADS)
Silva, Cleiton C.; de Albuquerque, Victor H. C.; Moura, Cícero R. O.; Aguiar, Willys M.; Farias, Jesualdo P.
2009-04-01
The present work evaluates the two-layer technique on the heat affected zone (HAZ) of AISI 4140 steel welded with different heat input levels between the first and second layer. The weld heat input levels selected by the Higuchi test were 5/5, 5/10, and 15/5 kJ/cm. The evaluation of the refining and/or tempering of the coarsened grain HAZ of the first layer was carried out using metallographic tests, microhardness measurements, and the Charpy-V impact test. The tempering of the first layer was only reached when the weld heat input ratio was 5/5 kJ/cm. The results of the Charpy-V impact test showed that the two-layer technique was efficient, from the point of view of toughness, since the toughness values reached were greater than the base metal for all weld heat input ratios applied. The results obtained indicate that the best performance of the two-layer deposition technique was for the weld heat input ratio 5/5 kJ/cm employing low heat input.
Nishiguchi, Shu; Yorozu, Ayanori; Adachi, Daiki; Takahashi, Masaki; Aoyama, Tomoki
2017-08-08
The Timed Up and Go (TUG) test may be a useful tool to detect not only mobility impairment but also possible cognitive impairment. In this cross-sectional study, we used the TUG test to investigate the associations between trajectory-based spatial parameters measured by laser range sensor (LRS) and cognitive impairment in community-dwelling older adults. The participants were 63 community-dwelling older adults (mean age, 73.0 ± 6.3 years). The trajectory-based spatial parameters during the TUG test were measured using an LRS. In each forward and backward phase, we calculated the minimum distance from the marker, the maximum distance from the x-axis (center line), the length of the trajectories, and the area of region surrounded by the trajectory of the center of gravity and the x-axis (center line). We measured mild cognitive impairment using the Mini-Mental State Examination score (26/27 was the cut-off score for defining mild cognitive impairment). Compared with participants with normal cognitive function, those with mild cognitive impairment exhibited the following trajectory-based spatial parameters: short minimum distance from the marker (p = 0.044), narrow area of center of gravity in the forward phase (p = 0.012), and a large forward/whole phase ratio of the area of the center of gravity (p = 0.026) during the TUG test. In multivariate logistic regression analyses, a short minimum distance from the marker (odds ratio [OR]: 0.82, 95% confidence interval [CI]: 0.69-0.98), narrow area of the center of gravity in the forward phase (OR: 0.01, 95% CI: 0.00-0.36), and large forward/whole phase ratio of the area of the center of gravity (OR: 0.94, 95% CI: 0.88-0.99) were independently associated with mild cognitive impairment. In conclusion, our results indicate that some of the trajectory-based spatial parameters measured by LRS during the TUG test were independently associated with cognitive impairment in older adults. In particular, older adults with cognitive impairment exhibit shorter minimum distances from the marker and asymmetrical trajectories during the TUG test.
Energy Efficient Engine acoustic supporting technology report
NASA Technical Reports Server (NTRS)
Lavin, S. P.; Ho, P. Y.
1985-01-01
The acoustic development of the Energy Efficient Engine combined testing and analysis using scale model rigs and an integrated Core/Low Spool demonstration engine. The scale model tests show that a cut-on blade/vane ratio fan with a large spacing (S/C = 2.3) is as quiet as a cut-off blade/vane ratio with a tighter spacing (S/C = 1.27). Scale model mixer tests show that separate flow nozzles are the noisiest, conic nozzles the quietest, with forced mixers in between. Based on projections of ICLS data the Energy Efficient Engine (E3) has FAR 36 margins of 3.7 EPNdB at approach, 4.5 EPNdB at full power takeoff, and 7.2 EPNdB at sideline conditions.
Tracer element for indoor PM2.5 in China migrated from outdoor
NASA Astrophysics Data System (ADS)
Ji, Wenjing; Li, Hongyu; Zhao, Bin; Deng, Furong
2018-03-01
Sulfur and nickel have been widely used as tracers of outdoor PM2.5 (particulate matter with an aerodynamic diameter ≤ 2.5 μm) in the United States and Europe; however, their feasibility as tracers has not been verified yet in China. We aim to verify whether sulfur or nickel could be used as a tracer element and, if not, to identify a suitable tracer element for outdoor PM2.5 in China. We conduct two types of experiments, namely, preliminary and main-study experiments. We analyze 102 pairs of indoor and outdoor PM2.5 samples in Beijing. The correlation between the I/O (indoor/outdoor) ratio of an element and the I/O ratio of total PM2.5 is one of the criteria used to test whether this element can be used as a tracer element. The average concentrations of nickel are found to be below the detection limits in both preliminary and main-study tests. Thus, nickel cannot be used as a tracer element in China. Based on the correlations of elemental I/O ratios and the I/O ratio of total PM2.5 in the preliminary and main-study tests, sulfur also cannot be used as a tracer element; however, it should be feasible to use iron as a tracer element in Beijing according to the test results. The estimated infiltration factor obtained by using iron as tracer is extremely consistent with the calculations based on the mass balance model. In summary, iron is found to be more suitable as a tracer for outdoor PM2.5 in Beijing than sulfur or nickel.
Bioflocculation of grey water for improved energy recovery within decentralized sanitation concepts.
Hernández Leal, L; Temmink, H; Zeeman, G; Buisman, C J N
2010-12-01
Bioflocculation of grey water was tested with a lab-scale membrane bioreactor in order to concentrate the COD. Three concentration factors were tested based on the ratio of sludge retention time (SRT) and hydraulic retention time (HRT): 3, 8 and 12. COD concentration factor was up to 7.1, achieving a final concentration of 7.2 g COD L(-1). Large fractions of suspended COD were recovered in the concentrate (57%, 81% and 82% at SRT/HRT ratios of 3, 8 and 12, respectively) indicating a strong bioflocculation of grey water. A maximum of 11% of COD mineralization of grey water was measured at the longest SRT tested (1 d). The integration of bioflocculation of grey water in decentralized sanitation concepts may increase the overall production of methane by 73%, based on the biogas produced by black water only. Therefore, bioflocculation is a promising grey water pre-treatment step for energy recovery within decentralized sanitation concepts. 2010 Elsevier Ltd. All rights reserved.
Application-Oriented Chemical Optimization of a Metakaolin Based Geopolymer.
Ferone, Claudio; Colangelo, Francesco; Roviello, Giuseppina; Asprone, Domenico; Menna, Costantino; Balsamo, Alberto; Prota, Andrea; Cioffi, Raffaele; Manfredi, Gaetano
2013-05-10
In this study the development of a metakaolin based geopolymeric mortar to be used as bonding matrix for external strengthening of reinforced concrete beams is reported. Four geopolymer formulations have been obtained by varying the composition of the activating solution in terms of SiO₂/Na₂O ratio. The obtained samples have been characterized from a structural, microstructural and mechanical point of view. The differences in structure and microstructure have been correlated to the mechanical properties. A major issue of drying shrinkage has been encountered in the high Si/Al ratio samples. In the light of the characterization results, the optimal geopolymer composition was then applied to fasten steel fibers to reinforced concrete beams. The mechanical behavior of the strengthened reinforced beams was evaluated by four-points bending tests, which were performed also on reinforced concrete beams as they are for comparison. The preliminary results of the bending tests point out an excellent behavior of the geopolymeric mixture tested, with the failure load of the reinforced beams roughly twice that of the control beam.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Best, D.
Reillex™ HPQ resin was developed by Los Alamos Laboratory and Reilly Industries Inc. in an effort to increase safety and process efficiency during the recovery and purification of plutonium. Ionac™ A-641, another strong base macroporous anion exchange resin used in the nuclear industry, was known to undergo a runaway reaction in hot nitric acid solutions. Because of this, an extensive amount of thermal analyses testing on the Reillex™ HPQ resin in SRNL was performed in 1999-2001 prior to use. A report on the thermal stability qualification of the Reillex™ HPQ resin in 8M (35%) and 12M (53%) HNO 3 wasmore » reported in 2000. In 2001, the reactivity of Reillex™ HPQ resin in 14.4M (64%) HNO 3 was evaluated. In January of 2001, thermal stability scoping tests were performed on irradiated Reillex™ HPQ resin in 14.4M (64%) HNO 3 (as a worst case scenario) and the results sent to Fauske and Associates to calculate a rupture disk size for the HB-Line resin column. A technical report by Fauske and Associates was issued in February 2001 recommending a 2.0” vent line with a rupture disk set pressure of 60 psig. This calculation was based on ARSST thermal analyses scoping tests at SRNL in which 4 grams of dried resin and 6.0 grams of 64% nitric acid in a 10 gram test cell, produced a maximum pressure rate (dP/dt) of 720 psi/min (12 psi/sec) and a maximum temperature of 250 °C. In 2015, a new batch of Reillex™ HPQ resin was manufactured by Vertellus Industries. A test sample of the resin was sent to SRNL to perform acceptance and qualification thermal stability testing using the ARSST. During these tests, method development was performed to ensure that a representative resin to acid ratios were used while running the tests in the ARSST. Fauske and Associates recommended to either use a full test cell representative of the HB-Line column or a 10 gram sample in the test cell that was representative of the ratios of resin to nitric acid in the actual HB-Line column. An observation was made during method development testing that the 4 grams of resin to 6 grams of 64% acid ratio used in 2001 to determine the rupture disk size did not entirely wet the resin and was not representative of the actual HB-Line column. The results of this study raised questions as to whether the ratio of 4 grams of resin to 6 grams of 64% nitric acid recommended by Fauske and Associates in 2001 was the correct ratio.« less
Study on the oxidative stability of poly a-olefin aviation lubricating base oil using PDSC method
NASA Astrophysics Data System (ADS)
Wu, N.; Fei, Y. W.; Yang, H. W.; Wang, Y. M.; Zong, Z. M.
2016-08-01
The oxidation stability of the domestic and import PAO aviation lubricating base oil was studied by the method of pressurized differential scanning calorimetry testing the initial oxidation temperature. The effects of anti-oxidants were investigated, and the best ratio of antioxidants was determined.
Ground-based testing of the dynamics of flexible space structures using band mechanisms
NASA Technical Reports Server (NTRS)
Yang, L. F.; Chew, Meng-Sang
1991-01-01
A suspension system based on a band mechanism is studied to provide the free-free conditions for ground based validation testing of flexible space structures. The band mechanism consists of a noncircular disk with a convex profile, preloaded by torsional springs at its center of rotation so that static equilibrium of the test structure is maintained at any vertical location; the gravitational force will be directly counteracted during dynamic testing of the space structure. This noncircular disk within the suspension system can be configured to remain unchanged for test articles with the different weights as long as the torsional spring is replaced to maintain the originally designed frequency ratio of W/k sub s. Simulations of test articles which are modeled as lumped parameter as well as continuous parameter systems, are also presented.
Rajagopal, Rajinikanth; Béline, Fabrice
2011-05-01
This study aimed to develop a biochemical-test mainly to evaluate the hydrolytic-potential of different substrates and to apply this test to characterize various organic substrates. Outcome of this study can be used for optimization of the WWTPs through enhancement of N/P removal or anaerobic digestion. Out of four series of batch experiments, the first two tests were conducted to determine the optimal operating conditions (test duration, inoculum-ratio etc.) for the hydrolytic-potential test using secondary and synthetically-prepared sludges. Based on the results (generation of CODs, pH and VFA), test duration was fixed between 6 and 7d allowing to attain maximum hydrolysis and to avoid methanogenesis. Effect of inoculum-ratios on acid fermentation of sludge was not significantly noticed. Using this methodology, third and fourth tests were performed to characterize various organic substrates namely secondary, pre-treated sludge, pig and two different cattle slurries. VFA production was shown to be substantially dependent on substrates types. Copyright © 2011 Elsevier Ltd. All rights reserved.
PolyMUMPs MEMS device to measure mechanical stiffness of single cells in aqueous media
NASA Astrophysics Data System (ADS)
Warnat, S.; King, H.; Forbrigger, C.; Hubbard, T.
2015-02-01
A method of experimentally determining the mechanical stiffness of single cells by using differential displacement measurements in a two stage spring system is presented. The spring system consists of a known MEMS reference spring and an unknown cellular stiffness: the ratio of displacements is related to the ratio of stiffness. A polyMUMPs implementation for aqueous media is presented and displacement measurements made from optical microphotographs using a FFT based displacement method with a repeatability of ~20 nm. The approach was first validated on a MEMS two stage spring system of known stiffness. The measured stiffness ratios of control structures (i) MEMS spring systems and (ii) polystyrene microspheres were found to agree with theoretical values. Mechanical tests were then performed on Saccharomyces cerevisiae (Baker’s yeast) in aqueous media. Cells were placed (using a micropipette) inside MEMS measuring structures and compressed between two jaws using an electrostatic actuator and displacements measured. Tested cells showed stiffness values between 5.4 and 8.4 N m-1 with an uncertainty of 11%. In addition, non-viable cells were tested by exposing viable cells to methanol. The resultant mean cell stiffness dropped by factor of 3 × and an explicit discrimination between viable and non-viable cells based on mechanical stiffness was seen.
Bertoldi, Eduardo G; Stella, Steffan F; Rohde, Luis E; Polanczyk, Carisi A
2016-05-01
Several tests exist for diagnosing coronary artery disease, with varying accuracy and cost. We sought to provide cost-effectiveness information to aid physicians and decision-makers in selecting the most appropriate testing strategy. We used the state-transitions (Markov) model from the Brazilian public health system perspective with a lifetime horizon. Diagnostic strategies were based on exercise electrocardiography (Ex-ECG), stress echocardiography (ECHO), single-photon emission computed tomography (SPECT), computed tomography coronary angiography (CTA), or stress cardiac magnetic resonance imaging (C-MRI) as the initial test. Systematic review provided input data for test accuracy and long-term prognosis. Cost data were derived from the Brazilian public health system. Diagnostic test strategy had a small but measurable impact in quality-adjusted life-years gained. Switching from Ex-ECG to CTA-based strategies improved outcomes at an incremental cost-effectiveness ratio of 3100 international dollars per quality-adjusted life-year. ECHO-based strategies resulted in cost and effectiveness almost identical to CTA, and SPECT-based strategies were dominated because of their much higher cost. Strategies based on stress C-MRI were most effective, but the incremental cost-effectiveness ratio vs CTA was higher than the proposed willingness-to-pay threshold. Invasive strategies were dominant in the high pretest probability setting. Sensitivity analysis showed that results were sensitive to costs of CTA, ECHO, and C-MRI. Coronary CT is cost-effective for the diagnosis of coronary artery disease and should be included in the Brazilian public health system. Stress ECHO has a similar performance and is an acceptable alternative for most patients, but invasive strategies should be reserved for patients at high risk. © 2016 Wiley Periodicals, Inc.
Kim, Jane J; Wright, Thomas C; Goldie, Sue J
2005-06-15
European countries with established cytology-based screening programs for cervical cancer will soon face decisions about whether to incorporate human papillomavirus (HPV) DNA testing and what strategies will be most cost-effective. We assessed the cost-effectiveness of incorporating HPV DNA testing into existing cervical cancer screening programs in the United Kingdom, The Netherlands, France, and Italy. We created a computer-based model of the natural history of cervical carcinogenesis for each using country-specific data on cervical cancer risk and compared each country's current screening policy with two new strategies: 1) cytology throughout a woman's lifetime, using HPV DNA testing as a triage strategy for equivocal cytology results ("HPV triage"), as well as 2) cytology until age 30 years and HPV DNA testing in combination with cytology in women more than 30 years of age ("combination testing"). Outcomes included reduction in lifetime cervical cancer risk, increase in life expectancy, lifetime costs, and incremental cost-effectiveness ratios, expressed as cost per year of life saved. We explored alternative protocols and conducted sensitivity analysis on key parameters of the model over a relevant range of values to identify the most cost-effective options for each country. Both HPV DNA testing strategies, HPV triage and combination testing, were more effective than each country's status quo screening policy. Incremental cost-effectiveness ratios for HPV triage were less than $13,000 per year of life saved, whereas those for combination testing ranged from $9800 to $75,900 per year of life saved, depending on screening interval. We identified options that would be very cost-effective (i.e., cost-effectiveness ratio less than the gross domestic product per capita) in each of the four countries. HPV DNA testing has the potential to improve health benefits at a reasonable cost compared with current screening policies in four European countries.
Coded excitation for infrared non-destructive testing of carbon fiber reinforced plastics.
Mulaveesala, Ravibabu; Venkata Ghali, Subbarao
2011-05-01
This paper proposes a Barker coded excitation for defect detection using infrared non-destructive testing. Capability of the proposed excitation scheme is highlighted with recently introduced correlation based post processing approach and compared with the existing phase based analysis by taking the signal to noise ratio into consideration. Applicability of the proposed scheme has been experimentally validated on a carbon fiber reinforced plastic specimen containing flat bottom holes located at different depths.
Crespo-Bojorque, Paola; Toro, Juan M
2015-02-01
Traditionally, physical features in musical chords have been proposed to be at the root of consonance perception. Alternatively, recent studies suggest that different types of experience modulate some perceptual foundations for musical sounds. The present study tested whether the mechanisms involved in the perception of consonance are present in an animal with no extensive experience with harmonic stimuli and a relatively limited vocal repertoire. In Experiment 1, rats were trained to discriminate consonant from dissonant chords and tested to explore whether they could generalize such discrimination to novel chords. In Experiment 2, we tested if rats could discriminate between chords differing only in their interval ratios and generalize them to different octaves. To contrast the observed pattern of results, human adults were tested with the same stimuli in Experiment 3. Rats successfully discriminated across chords in both experiments, but they did not generalize to novel items in either Experiment 1 or Experiment 2. On the contrary, humans not only discriminated among both consonance-dissonance categories, and among sets of interval ratios, they also generalized their responses to novel items. These results suggest that experience with harmonic sounds may be required for the construction of categories among stimuli varying in frequency ratios. However, the discriminative capacity observed in rats suggests that at least some components of auditory processing needed to distinguish chords based on their interval ratios are shared across species. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Extended International Normalized Ratio testing intervals for warfarin-treated patients.
Barnes, G D; Kong, X; Cole, D; Haymart, B; Kline-Rogers, E; Almany, S; Dahu, M; Ekola, M; Kaatz, S; Kozlowski, J; Froehlich, J B
2018-05-15
Essentials Warfarin typically requires International Normalized Ratio (INR) testing at least every 4 weeks. We implemented extended INR testing for stable warfarin patients in six anticoagulation clinics. Use of extended INR testing increased from 41.8% to 69.3% over the 3 year study. Use of extended INR testing appeared safe and effective. Background A previous single-center randomized trial suggested that patients with stable International Normalized Ratio (INR) values could safely receive INR testing as infrequently as every 12 weeks. Objective To test the success of implementation of an extended INR testing interval for stable warfarin patients in a practice-based, multicenter collaborative of anticoagulation clinics. Methods At six anticoagulation clinics, patients were identified as being eligible for extended INR testing on the basis of prior INR value stability and minimal warfarin dose changes between 2014 and 2016. We assessed the frequency with which anticoagulation clinic providers recommended an extended INR testing interval (> 5 weeks) to eligible patients. We also explored safety outcomes for eligible patients, including next INR values, bleeding events, and emergency department visits. Results At least one eligible period for extended INR testing was identified in 890 of 3362 (26.5%) warfarin-treated patients. Overall, the use of extended INR testing in eligible patients increased from 41.8% in the first quarter of 2014 to 69.3% in the fourth quarter of 2016. The number of subsequent out-of-range next INR values were similar between eligible patients who did and did not have an extended INR testing interval (27.3% versus 28.4%, respectively). The numbers of major bleeding events were not different between the two groups, but rates of clinically relevant non-major bleeding (0.02 per 100 patient-years versus 0.09 per 100 patient-years) and emergency department visits (0.07 per 100 patient-years versus 0.19 per 100 patient-years) were lower for eligible patients with extended INR testing intervals than for those with non-extended INR testing intervals. Conclusions Extended INR testing for stable warfarin patients can be successfully and safely implemented in diverse, practice-based anticoagulation clinic settings. © 2018 International Society on Thrombosis and Haemostasis.
NASA Astrophysics Data System (ADS)
Zhou, Ting; Cheng, Xudong; Pan, Yuelei; Li, Congcong; Gong, Lunlun; Zhang, Heping
2018-04-01
In order to maintain the integrity, glass fiber (GF) reinforced silica aerogel composites were synthesized using methltrimethoxysilane (MTMS) and water glass co-precursor by freeze drying method. The composites were characterized by scanning electron microscopy, Brunauer-Emmett-Teller analysis, uniaxial compressive test, three-point bending test, thermal conductivity analysis, contact angle test, TG-DSC analysis. It was found that the molar ratio of MTMS/water glass could significantly affect the properties of composites. The bulk density and thermal conductivity first decreased and then increased with the increasing molar ratio. The composites showed remarkable mechanical strength and flexibility compared with pure silica aerogel. Moreover, when the molar ratio is 1.8, the composites showed high specific surface area (870.9 m2/g), high contact angle (150°), great thermal stability (560 °C) and low thermal conductivity (0.0248 W/m·K). These outstanding properties indicate that GF/aerogels have broad prospects in the field of thermal insulation.
Test experience, 490 N high performance (321 sec Isp) engine
NASA Technical Reports Server (NTRS)
Schoenman, L.; Rosenberg, S. D.; Jassowski, D. M.
1992-01-01
Engines with area ratios of 44:1 and 286:1 are tested by means of hot fire tests using the NTO/MMH bipropellant to maximize the performance of the combined technologies. The low-thrust engine systems are designed with oxidation resistant materials that can operate at temperatures of more than 2204 C for tens of hours. The chamber is attached to the injector in a configuration that prevents overheating of the injector, valve, and the spacecraft interface. Three injectors with 44:1 area ratios are capable of nominal specific impulse values of 309 sec, and a performance of 321 lbf-sec/lbm is noted for an all-welded engine assembly with area ratio of 286:1. The all-welded engine is shown to have an acceptable design margin for thermal characteristics. High-performance liquid apogee engines are shown to perform optimally when based on iridium/rhenium chamber technology, use of a special platelet injector, and the minimization of losses due to fuel-film cooling.
MacCabe, J H; Sariaslan, A; Almqvist, C; Lichtenstein, P; Larsson, H; Kyaga, S
2018-06-01
Many studies have addressed the question of whether mental disorder is associated with creativity, but high-quality epidemiological evidence has been lacking.AimsTo test for an association between studying a creative subject at high school or university and later mental disorder. In a case-control study using linked population-based registries in Sweden (N = 4 454 763), we tested for associations between tertiary education in an artistic field and hospital admission with schizophrenia (N = 20 333), bipolar disorder (N = 28 293) or unipolar depression (N = 148 365). Compared with the general population, individuals with an artistic education had increased odds of developing schizophrenia (odds ratio = 1.90, 95% CI = [1.69; 2.12]) bipolar disorder (odds ratio = 1.62 [1.50; 1.75]) and unipolar depression (odds ratio = 1.39 [1.34; 1.44]. The results remained after adjustment for IQ and other potential confounders. Students of artistic subjects at university are at increased risk of developing schizophrenia, bipolar disorder and unipolar depression in adulthood.Declaration of interestNone.
World of Forensic Laboratory Testing
... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... View sources NOTE: This article is based on research that utilizes the sources cited here as well ...
Four in vivo g-ratio-weighted imaging methods: Comparability and repeatability at the group level.
Ellerbrock, Isabel; Mohammadi, Siawoosh
2018-01-01
A recent method, denoted in vivo g-ratio-weighted imaging, has related the microscopic g-ratio, only accessible by ex vivo histology, to noninvasive MRI markers for the fiber volume fraction (FVF) and myelin volume fraction (MVF). Different MRI markers have been proposed for g-ratio weighted imaging, leaving open the question which combination of imaging markers is optimal. To address this question, the repeatability and comparability of four g-ratio methods based on different combinations of, respectively, two imaging markers for FVF (tract-fiber density, TFD, and neurite orientation dispersion and density imaging, NODDI) and two imaging markers for MVF (magnetization transfer saturation rate, MT, and, from proton density maps, macromolecular tissue volume, MTV) were tested in a scan-rescan experiment in two groups. Moreover, it was tested how the repeatability and comparability were affected by two key processing steps, namely the masking of unreliable voxels (e.g., due to partial volume effects) at the group level and the calibration value used to link MRI markers to MVF (and FVF). Our data showed that repeatability and comparability depend largely on the marker for the FVF (NODDI outperformed TFD), and that they were improved by masking. Overall, the g-ratio method based on NODDI and MT showed the highest repeatability (90%) and lowest variability between groups (3.5%). Finally, our results indicate that the calibration procedure is crucial, for example, calibration to a lower g-ratio value (g = 0.6) than the commonly used one (g = 0.7) can change not only repeatability and comparability but also the reported dependency on the FVF imaging marker. Hum Brain Mapp 39:24-41, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Ten-year change in plasma amyloid beta levels and late-life cognitive decline.
Okereke, Olivia I; Xia, Weiming; Selkoe, Dennis J; Grodstein, Francine
2009-10-01
Plasma levels of amyloid beta peptide (Abeta) are potential biomarkers of early cognitive impairment and decline and of Alzheimer disease risk. To relate midlife plasma Abeta measures and 10-year change in plasma Abeta measures since midlife to late-life cognitive decline. Prospective study of a population-based sample. Academic research. Plasma Abeta40 and Abeta42 levels were measured in 481 Nurses' Health Study participants in late midlife (mean age, 63.6 years) and again 10 years later (mean age, 74.6 years). Cognitive testing also began 10 years after the initial blood draw. Participants completed 3 repeated telephone-based assessments (mean span, 4.1 years). Multivariable linear mixed-effects models were used to estimate relations of midlife plasma Abeta40 to Abeta42 ratios and Abeta42 levels to late-life cognitive decline, as well as relations of 10-year change in Abeta40 to Abeta42 ratios and Abeta42 levels to cognitive decline. The 3 primary outcomes were the Telephone Interview for Cognitive Status (TICS) findings, a global score averaging the results of all tests (TICS, immediate and delayed verbal recall, category fluency, and attention), and a verbal memory score averaging the results of 4 tests of verbal recall. Higher midlife plasma Abeta40 to Abeta42 ratios were associated with worse late-life decline on the global score (P = .04 for trend). Furthermore, increase in Abeta40 to Abeta42 ratios since midlife predicted greater decline in the global score (P = .03 for trend) and in the TICS (P = .02 for trend). There was no association of cognitive decline with midlife plasma Abeta42 levels alone or with change in Abeta42 levels since midlife. In this large community-dwelling sample, higher plasma Abeta40 to Abeta42 ratios in late midlife and increases in Abeta40 to Abeta42 ratios 10 years later were significantly associated with greater decline in global cognition at late life.
Royston, Patrick; Parmar, Mahesh K B
2014-08-07
Most randomized controlled trials with a time-to-event outcome are designed and analysed under the proportional hazards assumption, with a target hazard ratio for the treatment effect in mind. However, the hazards may be non-proportional. We address how to design a trial under such conditions, and how to analyse the results. We propose to extend the usual approach, a logrank test, to also include the Grambsch-Therneau test of proportional hazards. We test the resulting composite null hypothesis using a joint test for the hazard ratio and for time-dependent behaviour of the hazard ratio. We compute the power and sample size for the logrank test under proportional hazards, and from that we compute the power of the joint test. For the estimation of relevant quantities from the trial data, various models could be used; we advocate adopting a pre-specified flexible parametric survival model that supports time-dependent behaviour of the hazard ratio. We present the mathematics for calculating the power and sample size for the joint test. We illustrate the methodology in real data from two randomized trials, one in ovarian cancer and the other in treating cellulitis. We show selected estimates and their uncertainty derived from the advocated flexible parametric model. We demonstrate in a small simulation study that when a treatment effect either increases or decreases over time, the joint test can outperform the logrank test in the presence of both patterns of non-proportional hazards. Those designing and analysing trials in the era of non-proportional hazards need to acknowledge that a more complex type of treatment effect is becoming more common. Our method for the design of the trial retains the tools familiar in the standard methodology based on the logrank test, and extends it to incorporate a joint test of the null hypothesis with power against non-proportional hazards. For the analysis of trial data, we propose the use of a pre-specified flexible parametric model that can represent a time-dependent hazard ratio if one is present.
sFlt-1/PlGF ratio test for pre-eclampsia: an economic assessment for the UK.
Vatish, M; Strunz-McKendry, T; Hund, M; Allegranza, D; Wolf, C; Smare, C
2016-12-01
To assess the economic impact of introducing into clinical practice in the UK the soluble fms-like tyrosine kinase (sFlt-1) to placental growth factor (PlGF) ratio test for guiding the management of pre-eclampsia. We used an economic model estimating the incremental value of information, from a UK National Health Service payer's perspective, generated by the sFlt-1/PlGF ratio test, compared with current diagnostic procedures, in guiding the management of women with suspected pre-eclampsia. The economic model estimated costs associated with the diagnosis and management of pre-eclampsia in pregnant women between 24 + 0 and 36 + 6 weeks' gestation, managed in either a 'test' scenario in which the sFlt-1/PlGF test is used in addition to current diagnostic procedures, or a 'no-test' scenario in which clinical decisions are based on current diagnostic procedures alone. Test characteristics and resource use were derived from PROGNOSIS, a non-interventional study in women presenting with clinical suspicion of pre-eclampsia. The main outcome measure from the economic model was the cost per patient per episode of care, from first suspicion of pre-eclampsia to birth. Introduction of the sFlt-1/PlGF ratio test into clinical practice is expected to result in cost savings of £344 per patient compared with a no-test scenario. Savings are generated primarily through an improvement in diagnostic accuracy and subsequent reduction in unnecessary hospitalization. Introducing the sFlt-1/PlGF ratio test into clinical practice in the UK was shown to be cost-saving by reducing unnecessary hospitalization of women at low risk of developing pre-eclampsia. In addition, the test ensures that those women at higher risk are identified and managed appropriately. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology. © 2016 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
Bian, Wei; Li, Yan; Crane, Jason C; Nelson, Sarah J
2018-02-01
To implement a fully automated atlas-based method for prescribing 3D PRESS MR spectroscopic imaging (MRSI). The PRESS selected volume and outer-volume suppression bands were predefined on the MNI152 standard template image. The template image was aligned to the subject T 1 -weighted image during a scan, and the resulting transformation was then applied to the predefined prescription. To evaluate the method, H-1 MRSI data were obtained in repeat scan sessions from 20 healthy volunteers. In each session, datasets were acquired twice without repositioning. The overlap ratio of the prescribed volume in the two sessions was calculated and the reproducibility of inter- and intrasession metabolite peak height and area ratios was measured by the coefficient of variation (CoV). The CoVs from intra- and intersession were compared by a paired t-test. The average overlap ratio of the automatically prescribed selection volumes between two sessions was 97.8%. The average voxel-based intersession CoVs were less than 0.124 and 0.163 for peak height and area ratios, respectively. Paired t-test showed no significant difference between the intra- and intersession CoVs. The proposed method provides a time efficient method to prescribe 3D PRESS MRSI with reproducible imaging positioning and metabolite measurements. Magn Reson Med 79:636-642, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
A readers' guide to the interpretation of diagnostic test properties: clinical example of sepsis.
Fischer, Joachim E; Bachmann, Lucas M; Jaeschke, Roman
2003-07-01
One of the most challenging practical and daily problems in intensive care medicine is the interpretation of the results from diagnostic tests. In neonatology and pediatric intensive care the early diagnosis of potentially life-threatening infections is a particularly important issue. A plethora of tests have been suggested to improve diagnostic decision making in the clinical setting of infection which is a clinical example used in this article. Several criteria that are critical to evidence-based appraisal of published data are often not adhered to during the study or in reporting. To enhance the critical appraisal on articles on diagnostic tests we discuss various measures of test accuracy: sensitivity, specificity, receiver operating characteristic curves, positive and negative predictive values, likelihood ratios, pretest probability, posttest probability, and diagnostic odds ratio. We suggest the following minimal requirements for reporting on the diagnostic accuracy of tests: a plot of the raw data, multilevel likelihood ratios, the area under the receiver operating characteristic curve, and the cutoff yielding the highest discriminative ability. For critical appraisal it is mandatory to report confidence intervals for each of these measures. Moreover, to allow comparison to the readers' patient population authors should provide data on study population characteristics, in particular on the spectrum of diseases and illness severity.
Li, Bo; Sun, Zhiqiang; Li, Xiaohan; Li, Xiaoxi; Wang, Han; Chen, Weijiao; Chen, Peng; Qiao, Mengran; Mao, Yuanli
2017-04-01
There have been many inconsistent reports about the performance of histidine-rich protein 2 (HRP2) and lactate dehydrogenase (LDH) antigens as rapid diagnostic tests (RDTs) for the diagnosis of past Plasmodium falciparum infections. This meta-analysis was performed to determine the performance of pfHRP2 versus pLDH antigen RDTs in the detection of P. falciparum . After a systematic review of related studies, Meta-DiSc 1.4 software was used to calculate the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR). Forest plots and summary receiver operating characteristic curve (SROC) analysis were used to summarize the overall test performance. Fourteen studies which met the inclusion criteria were included in the meta-analysis. The summary performances for pfHRP2- and pLDH-based tests in the diagnosis of P. falciparum infections were as follows: pooled sensitivity, 96.3% (95.8-96.7%) vs. 82.6% (81.7-83.5%); specificity, 86.1% (85.3-86.8%) vs. 95.9% (95.4-96.3%); diagnostic odds ratio (DOR), 243.31 (97.679-606.08) vs. 230.59 (114.98-462.42); and area under ROCs, 0.9822 versus 0.9849 (all p < 0.001). The two RDTs performed satisfactorily for the diagnosis of P. falciparum , but the pLDH tests had higher specificity, whereas the pfHRP2 tests had better sensitivity. The pfHRP2 tests had slightly greater accuracy compared to the pLDH tests. A combination of both antigens might be a more reliable approach for the diagnosis of malaria.
A close examination of double filtering with fold change and t test in microarray analysis
2009-01-01
Background Many researchers use the double filtering procedure with fold change and t test to identify differentially expressed genes, in the hope that the double filtering will provide extra confidence in the results. Due to its simplicity, the double filtering procedure has been popular with applied researchers despite the development of more sophisticated methods. Results This paper, for the first time to our knowledge, provides theoretical insight on the drawback of the double filtering procedure. We show that fold change assumes all genes to have a common variance while t statistic assumes gene-specific variances. The two statistics are based on contradicting assumptions. Under the assumption that gene variances arise from a mixture of a common variance and gene-specific variances, we develop the theoretically most powerful likelihood ratio test statistic. We further demonstrate that the posterior inference based on a Bayesian mixture model and the widely used significance analysis of microarrays (SAM) statistic are better approximations to the likelihood ratio test than the double filtering procedure. Conclusion We demonstrate through hypothesis testing theory, simulation studies and real data examples, that well constructed shrinkage testing methods, which can be united under the mixture gene variance assumption, can considerably outperform the double filtering procedure. PMID:19995439
Bakare, Muideen O; Ubochi, Vincent N; Okoroikpa, Ifeoma N; Aguocha, Chinyere M; Ebigbo, Peter O
2009-09-15
There may be need to assess intelligent quotient (IQ) scores in sub-Saharan African children with intellectual disability, either for the purpose of educational needs assessment or research. However, modern intelligence scales developed in the western parts of the world suffer limitation of widespread use because of the influence of socio-cultural variations across the world. This study examined the agreement between IQ scores estimation among Nigerian children with intellectual disability using clinicians' judgment based on International Classification of Diseases, tenth Edition(ICD - 10) criteria for mental retardation and caregivers judgment based on 'ratio IQ' scores calculated from estimated mental age in the context of socio-cultural milieu of the children. It proposed a viable option of IQ score assessment among sub-Saharan African children with intellectual disability, using a ratio of culture-specific estimated mental age and chronological age of the child in the absence of standardized alternatives, borne out of great diversity in socio-cultural context of sub-Saharan Africa. Clinicians and care-givers independently assessed the children in relation to their socio-cultural background. Clinicians assessed the IQ scores of the children based on the ICD - 10 diagnostic criteria for mental retardation. 'Ratio IQ' scores were calculated from the ratio of estimated mental age and chronological age of each child. The IQ scores as assessed by the clinicians were then compared with the 'ratio IQ' scores using correlation statistics. A total of forty-four (44) children with intellectual disability were assessed. There was a significant correlation between clinicians' assessed IQ scores and the 'ratio IQ' scores employing zero order correlation without controlling for the chronological age of the children (r = 0.47, df = 42, p = 0.001). First order correlation controlling for the chronological age of the children showed higher correlation score between clinicians' assessed IQ scores and 'ratio IQ' scores (r = 0.75, df = 41, p = 0.000). Agreement between clinicians' assessed IQ scores and 'ratio IQ' scores was good. 'Ratio IQ' test would provide a viable option of assessing IQ scores in sub-Saharan African children with intellectual disability in the absence of culture-appropriate standardized intelligence scales, which is often the case because of great diversity in socio-cultural structures of sub-Saharan Africa.
Retrospective analysis of RF heating measurements of passive medical implants.
Song, Ting; Xu, Zhiheng; Iacono, Maria Ida; Angelone, Leonardo M; Rajan, Sunder
2018-05-09
The test reports for the RF-induced heating of metallic devices of hundreds of medical implants have been provided to the U.S. Food and Drug Administration as a part of premarket submissions. The main purpose of this study is to perform a retrospective analysis of the RF-induced heating data provided in the reports to analyze the trends and correlate them with implant geometric characteristics. The ASTM-based RF heating test reports from 86 premarket U.S. Food and Drug Administration submissions were reviewed by three U.S. Food and Drug Administration reviewers. From each test report, the dimensions and RF-induced heating values for a given whole-body (WB) specific absorption rate (SAR) and local background (LB) SAR were extracted and analyzed. The data from 56 stents were analyzed as a subset to further understand heating trends and length dependence. For a given WB SAR, the LB/WB SAR ratio varied significantly across the test labs, from 2.3 to 11.3. There was an increasing trend on the temperature change per LB SAR with device length. The maximum heating for stents occurred at lengths of approximately 100 mm at 3 T, and beyond 150 mm at 1.5 T. Differences in the LB/WB SAR ratios across testing labs and various MRI scanners could lead to inconsistent WB SAR labeling. Magnetic resonance (MR) conditional labeling based on WB SAR should be derived from a conservative estimate of global LB/WB ratios. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Static performance tests of a flight-type STOVL ejector
NASA Technical Reports Server (NTRS)
Barankiewicz, Wendy S.
1991-01-01
The design and development of thrust augmenting STOVL ejectors has typically been based on experimental iteration (i.e., trial and error). Static performance tests of a full scale vertical lift ejector were performed at primary flow temperatures up to 1560 R (1100 F). Flow visualization (smoke generators and yarn tufts) were used to view the inlet air flow, especially around the primary nozzle and end plates. Performance calculations are presented for ambient temperatures close to 480 R (20 F) and 535 R (75 F) which simulate seasonal aircraft operating conditions. Resulting thrust augmentation ratios are presented as functions of nozzle pressure ratio and temperature.
Durability of an inorganic polymer concrete coating
NASA Astrophysics Data System (ADS)
Wasserman, Kenneth
The objective of the research program reported in this thesis is to evaluate the durability of an inorganic polymer composite coating exposed to freeze/thaw cycling and wet-dry cycling. Freeze/thaw cycling is performed following ASTM D6944-09 Standard Practice for Resistance of Cured Coatings to Thermal Cycling and wet/dry cycling is performed following guidelines set forth in a thesis written by Ronald Garon at Rutgers University. For both sets of experiments, four coating mixture proportions were evaluated. The variables were: silica/alumina ratio, mixing protocol using high shear and normal shear mixing, curing temperatures of 70 and 120 degrees Fahrenheit and use of nano size constituent materials. The mix with highest silica/alumina ratio was designated as Mix 1 and mixes with lower ratios were designated as Mix 2 and Mix 3. Mix 4 had nano silica particles. Four prisms were used for each variable including control that had no coating. The performance of the coating was evaluated using adhesion strength measured using: ASTM D7234 Test Method for Pull-Off Strength of Coatings on Concrete Using Portable Adhesion Testers. Tests were performed after every five consecutive cycles of thermal conditioning and six consecutive cycles of wet-dry exposure. Results from the thermal cycling and wet-dry testing demonstrate that all coating formulations are durable. The minimum adhesion strength was 300 psi even though a relatively weak base concrete surface was chosen for the study. The weak surface was chosen to simulate aged concrete surfaces present in actual field conditions. Due to the inherent nature of the test procedure the variation in test results is high. However, based on the test results, high shear mixer and high temperature curing are not recommended. As expected nano size constituent materials provide better performance.
Parametric Study of Shear Strength of Concrete Beams Reinforced with FRP Bars
NASA Astrophysics Data System (ADS)
Thomas, Job; Ramadass, S.
2016-09-01
Fibre Reinforced Polymer (FRP) bars are being widely used as internal reinforcement in structural elements in the last decade. The corrosion resistance of FRP bars qualifies its use in severe and marine exposure conditions in structures. A total of eight concrete beams longitudinally reinforced with FRP bars were cast and tested over shear span to depth ratio of 0.5 and 1.75. The shear strength test data of 188 beams published in various literatures were also used. The model originally proposed by Indian Standard Code of practice for the prediction of shear strength of concrete beams reinforced with steel bars IS:456 (Plain and reinforced concrete, code of practice, fourth revision. Bureau of Indian Standards, New Delhi, 2000) is considered and a modification to account for the influence of the FRP bars is proposed based on regression analysis. Out of the 196 test data, 110 test data is used for the regression analysis and 86 test data is used for the validation of the model. In addition, the shear strength of 86 test data accounted for the validation is assessed using eleven models proposed by various researchers. The proposed model accounts for compressive strength of concrete ( f ck ), modulus of elasticity of FRP rebar ( E f ), longitudinal reinforcement ratio ( ρ f ), shear span to depth ratio ( a/ d) and size effect of beams. The predicted shear strength of beams using the proposed model and 11 models proposed by other researchers is compared with the corresponding experimental results. The mean of predicted shear strength to the experimental shear strength for the 86 beams accounted for the validation of the proposed model is found to be 0.93. The result of the statistical analysis indicates that the prediction based on the proposed model corroborates with the corresponding experimental data.
NASA Technical Reports Server (NTRS)
Grant, Frederick C.; Sevier, John R., Jr.
1960-01-01
Wind-tunnel force tests of a number of wing-body combinations designed for high lift-drag ratio at a Mach number of 1.41 are reported. Five wings and six bodies were used in making up the various wing-body combinations investigated. All the wings had the same highly swept dis- continuously tapered plan form with NACA 65A-series airfoil sections 4 percent thick at the root tapering linearly to 3 percent thick at the tip. The bodies were based on the area distribution of a Sears-Haack body of revolution for minimum drag with a given length and volume. These wings and bodies were used to determine the effects of wing twist., wing twist and camber, wing leading-edge droop, a change from circular to elliptical body cross-sectional shape, and body indentation by the area-rule and streamline methods. The supersonic test Mach numbers were 1.41 and 2.01. The transonic test Mach number range was from 0.6 to 1.2. For the transition-fixed condition and at a Reynolds number of 2.7 x 10(exp 6) based on the mean aerodynamic chord, the maximum value of lift- drag ratio at a Mach number of 1.41 was 9.6 for a combination with a twisted wing and an indented body of elliptical cross section. The tests indicated that the transonic rise in minimum drag was low and did not change appreciably up to the highest test Mach number of 2.01. The lower values of lift-drag ratio obtained at a Mach number of 2.01 can be attributed to the increase of drag due to lift with Mach number.
Young, David W
2015-11-01
Historically, hospital departments have computed the costs of individual tests or procedures using the ratio of cost to charges (RCC) method, which can produce inaccurate results. To determine a more accurate cost of a test or procedure, the activity-based costing (ABC) method must be used. Accurate cost calculations will ensure reliable information about the profitability of a hospital's DRGs.
NASA Technical Reports Server (NTRS)
Csank, Jeffrey T.; Stueber, Thomas J.
2013-01-01
A dual flow-path inlet system is being tested to evaluate methodologies for a Turbine Based Combined Cycle (TBCC) propulsion system to perform a controlled inlet mode transition. Prior to experimental testing, simulation models are used to test, debug, and validate potential control algorithms. One simulation package being used for testing is the High Mach Transient Engine Cycle Code simulation, known as HiTECC. This paper discusses the closed loop control system, which utilizes a shock location sensor to improve inlet performance and operability. Even though the shock location feedback has a coarse resolution, the feedback allows for a reduction in steady state error and, in some cases, better performance than with previous proposed pressure ratio based methods. This paper demonstrates the design and benefit with the implementation of a proportional-integral controller, an H-Infinity based controller, and a disturbance observer based controller.
Hypothesis testing and earthquake prediction.
Jackson, D D
1996-04-30
Requirements for testing include advance specification of the conditional rate density (probability per unit time, area, and magnitude) or, alternatively, probabilities for specified intervals of time, space, and magnitude. Here I consider testing fully specified hypotheses, with no parameter adjustments or arbitrary decisions allowed during the test period. Because it may take decades to validate prediction methods, it is worthwhile to formulate testable hypotheses carefully in advance. Earthquake prediction generally implies that the probability will be temporarily higher than normal. Such a statement requires knowledge of "normal behavior"--that is, it requires a null hypothesis. Hypotheses can be tested in three ways: (i) by comparing the number of actual earth-quakes to the number predicted, (ii) by comparing the likelihood score of actual earthquakes to the predicted distribution, and (iii) by comparing the likelihood ratio to that of a null hypothesis. The first two tests are purely self-consistency tests, while the third is a direct comparison of two hypotheses. Predictions made without a statement of probability are very difficult to test, and any test must be based on the ratio of earthquakes in and out of the forecast regions.
Hypothesis testing and earthquake prediction.
Jackson, D D
1996-01-01
Requirements for testing include advance specification of the conditional rate density (probability per unit time, area, and magnitude) or, alternatively, probabilities for specified intervals of time, space, and magnitude. Here I consider testing fully specified hypotheses, with no parameter adjustments or arbitrary decisions allowed during the test period. Because it may take decades to validate prediction methods, it is worthwhile to formulate testable hypotheses carefully in advance. Earthquake prediction generally implies that the probability will be temporarily higher than normal. Such a statement requires knowledge of "normal behavior"--that is, it requires a null hypothesis. Hypotheses can be tested in three ways: (i) by comparing the number of actual earth-quakes to the number predicted, (ii) by comparing the likelihood score of actual earthquakes to the predicted distribution, and (iii) by comparing the likelihood ratio to that of a null hypothesis. The first two tests are purely self-consistency tests, while the third is a direct comparison of two hypotheses. Predictions made without a statement of probability are very difficult to test, and any test must be based on the ratio of earthquakes in and out of the forecast regions. PMID:11607663
Likelihood Ratios for Glaucoma Diagnosis Using Spectral Domain Optical Coherence Tomography
Lisboa, Renato; Mansouri, Kaweh; Zangwill, Linda M.; Weinreb, Robert N.; Medeiros, Felipe A.
2014-01-01
Purpose To present a methodology for calculating likelihood ratios for glaucoma diagnosis for continuous retinal nerve fiber layer (RNFL) thickness measurements from spectral domain optical coherence tomography (spectral-domain OCT). Design Observational cohort study. Methods 262 eyes of 187 patients with glaucoma and 190 eyes of 100 control subjects were included in the study. Subjects were recruited from the Diagnostic Innovations Glaucoma Study. Eyes with preperimetric and perimetric glaucomatous damage were included in the glaucoma group. The control group was composed of healthy eyes with normal visual fields from subjects recruited from the general population. All eyes underwent RNFL imaging with Spectralis spectral-domain OCT. Likelihood ratios for glaucoma diagnosis were estimated for specific global RNFL thickness measurements using a methodology based on estimating the tangents to the Receiver Operating Characteristic (ROC) curve. Results Likelihood ratios could be determined for continuous values of average RNFL thickness. Average RNFL thickness values lower than 86μm were associated with positive LRs, i.e., LRs greater than 1; whereas RNFL thickness values higher than 86μm were associated with negative LRs, i.e., LRs smaller than 1. A modified Fagan nomogram was provided to assist calculation of post-test probability of disease from the calculated likelihood ratios and pretest probability of disease. Conclusion The methodology allowed calculation of likelihood ratios for specific RNFL thickness values. By avoiding arbitrary categorization of test results, it potentially allows for an improved integration of test results into diagnostic clinical decision-making. PMID:23972303
Rodríguez-Cortés, Alhelí; Ojeda, Ana; Todolí, Felicitat; Alberola, Jordi
2013-01-31
Leishmania infantum (syn. Leishmania chagasi) is the etiological agent of a widespread serious zoonotic disease that affects both humans and dogs. Prevalence and incidence of the canine infection are important parameters to determine the risk and the ways to control this reemergent zoonosis. Unfortunately, there is not a gold standard test for Leishmania infection. Our aim was to assess the operative validity of commercial tests used to detect antibodies to Leishmania in serum samples from experimental infections. Three ELISA tests (LEISCAN(®) Leishmania ELISA Test, INGEZIM(®) LEISHMANIA, and INGEZIM(®) LEISHMANIA VET), three immunochromatographic tests (INGEZIM(®) LEISHMACROM, SNAP(®) Leishmania, and WITNESS(®) Leishmania), and one IFAT were evaluated. LEISCAN(®) Leishmania ELISA test achieved the highest sensitivity and accuracy (both 0.98). Specificity was 1 for all tests except for IFAT. All tests but IFAT obtained a positive predictive value of 1, while the maximum negative predictive value was achieved by LEISCAN(®) Leishmania ELISA Test (0.93). The best positive likelihood ratio was obtained by INGEZIM(®) LEISHMANIA VET (30.26), while the best negative likelihood ratio was obtained by LEISCAN(®) Leishmania ELISA Test (0.02). The highest diagnostic odds ratio was achieved by LEISCAN(®) Leishmania ELISA Test (729.00). The largest area under the ROC curve was obtained by LEISCAN(®) Leishmania ELISA Test (0.981). Quantitative ELISA based tests performmed better than qualitative tests ("Rapid Tests"), and the test best suited to detect Leishmania in infected dogs and to provide clinically useful information was LEISCAN(®) Leishmania ELISA Test. This and other results point also to the need of revising the status of IFAT as a gold standard for the diagnosis of leishmaniasis. Copyright © 2012 Elsevier B.V. All rights reserved.
A study of the lecithin/sphingomyelin ratio of amniotic fluid.
Gebhardt, D O; Beintema, A; de Rooij, R E; Wildeboer, F N; Merkus, J M
1975-10-15
1. There is a significant correlation between lecithin/sphingomyelin (L/S) ratios based on densitometry (L/S)D and L/S ratios based on phosphorus determinations ((L/S)P). 2. The fetal lung is mature when the (L/S)D, determined according to Verhoeven, A.G.J. and Merkus, H.M.W.M. (1974) Clin. Chim. Acta 53, 229--232, is 1.2. This value is equivalent to an (L/S)P of 1.8. 3. The acetone precipitation procedure, introduced by Gluck, L., Kulovich, M.V., Borer, R.C. and Keidel, W.N. (1974) Am. J. Obstet. Gynecol. 120, 142--155, is a necessary step for isolating surface-active lecithin. 4. Standardization of the (L/S)D test is feasible and should permit different laboratories to use the same transition point.
Optical and laser spectroscopic diagnostics for energy applications
NASA Astrophysics Data System (ADS)
Tripathi, Markandey Mani
The continuing need for greater energy security and energy independence has motivated researchers to develop new energy technologies for better energy resource management and efficient energy usage. The focus of this dissertation is the development of optical (spectroscopic) sensing methodologies for various fuels, and energy applications. A fiber-optic NIR sensing methodology was developed for predicting water content in bio-oil. The feasibility of using the designed near infrared (NIR) system for estimating water content in bio-oil was tested by applying multivariate analysis to NIR spectral data. The calibration results demonstrated that the spectral information can successfully predict the bio-oil water content (from 16% to 36%). The effect of ultraviolet (UV) light on the chemical stability of bio-oil was studied by employing laser-induced fluorescence (LIF) spectroscopy. To simulate the UV light exposure, a laser in the UV region (325 nm) was employed for bio-oil excitation. The LIF, as a signature of chemical change, was recorded from bio-oil. From this study, it was concluded that phenols present in the bio-oil show chemical instability, when exposed to UV light. A laser-induced breakdown spectroscopy (LIBS)-based optical sensor was designed, developed, and tested for detection of four important trace impurities in rocket fuel (hydrogen). The sensor can simultaneously measure the concentrations of nitrogen, argon, oxygen, and helium in hydrogen from storage tanks and supply lines. The sensor had estimated lower detection limits of 80 ppm for nitrogen, 97 ppm for argon, 10 ppm for oxygen, and 25 ppm for helium. A chemiluminescence-based spectroscopic diagnostics were performed to measure equivalence ratios in methane-air premixed flames. A partial least-squares regression (PLS-R)-based multivariate sensing methodology was investigated. It was found that the equivalence ratios predicted with the PLS-R-based multivariate calibration model matched with the experimentally measured equivalence ratios within 7 %. A comparative study was performed for equivalence ratios measurement in atmospheric premixed methane-air flames with ungated LIBS and chemiluminescence spectroscopy. It was reported that LIBS-based calibration, which carries spectroscopic information from a "point-like-volume," provides better predictions of equivalence ratios compared to chemiluminescence-based calibration, which is essentially a "line-of-sight" measurement.
Comparative quantification of human intestinal bacteria based on cPCR and LDR/LCR
Tang, Zhou-Rui; Li, Kai; Zhou, Yu-Xun; Xiao, Zhen-Xian; Xiao, Jun-Hua; Huang, Rui; Gu, Guo-Hao
2012-01-01
AIM: To establish a multiple detection method based on comparative polymerase chain reaction (cPCR) and ligase detection reaction (LDR)/ligase chain reaction (LCR) to quantify the intestinal bacterial components. METHODS: Comparative quantification of 16S rDNAs from different intestinal bacterial components was used to quantify multiple intestinal bacteria. The 16S rDNAs of different bacteria were amplified simultaneously by cPCR. The LDR/LCR was examined to actualize the genotyping and quantification. Two beneficial (Bifidobacterium, Lactobacillus) and three conditionally pathogenic bacteria (Enterococcus, Enterobacterium and Eubacterium) were used in this detection. With cloned standard bacterial 16S rDNAs, standard curves were prepared to validate the quantitative relations between the ratio of original concentrations of two templates and the ratio of the fluorescence signals of their final ligation products. The internal controls were added to monitor the whole detection flow. The quantity ratio between two bacteria was tested. RESULTS: cPCR and LDR revealed obvious linear correlations with standard DNAs, but cPCR and LCR did not. In the sample test, the distributions of the quantity ratio between each two bacterial species were obtained. There were significant differences among these distributions in the total samples. But these distributions of quantity ratio of each two bacteria remained stable among groups divided by age or sex. CONCLUSION: The detection method in this study can be used to conduct multiple intestinal bacteria genotyping and quantification, and to monitor the human intestinal health status as well. PMID:22294830
Comparative quantification of human intestinal bacteria based on cPCR and LDR/LCR.
Tang, Zhou-Rui; Li, Kai; Zhou, Yu-Xun; Xiao, Zhen-Xian; Xiao, Jun-Hua; Huang, Rui; Gu, Guo-Hao
2012-01-21
To establish a multiple detection method based on comparative polymerase chain reaction (cPCR) and ligase detection reaction (LDR)/ligase chain reaction (LCR) to quantify the intestinal bacterial components. Comparative quantification of 16S rDNAs from different intestinal bacterial components was used to quantify multiple intestinal bacteria. The 16S rDNAs of different bacteria were amplified simultaneously by cPCR. The LDR/LCR was examined to actualize the genotyping and quantification. Two beneficial (Bifidobacterium, Lactobacillus) and three conditionally pathogenic bacteria (Enterococcus, Enterobacterium and Eubacterium) were used in this detection. With cloned standard bacterial 16S rDNAs, standard curves were prepared to validate the quantitative relations between the ratio of original concentrations of two templates and the ratio of the fluorescence signals of their final ligation products. The internal controls were added to monitor the whole detection flow. The quantity ratio between two bacteria was tested. cPCR and LDR revealed obvious linear correlations with standard DNAs, but cPCR and LCR did not. In the sample test, the distributions of the quantity ratio between each two bacterial species were obtained. There were significant differences among these distributions in the total samples. But these distributions of quantity ratio of each two bacteria remained stable among groups divided by age or sex. The detection method in this study can be used to conduct multiple intestinal bacteria genotyping and quantification, and to monitor the human intestinal health status as well.
Dendrochemical response to soil fertilization
David R. DeWalle; Jeffrey S. Tepp; Bryan R. Swistock; Pamela J. Edwards; William E. Sharpe; Mary Beth Adams; James N. Kochenderfer
2003-01-01
Use of chemical element content of tree rings to detect soil acid or base changes was tested at 13 sites of former forest fertilization trials in the eastern United States and Canada. Ammonium sulfate or nitrogen fertilization was the typical acidification treatment, while lime added with or without other fertilizer was the typical base treatment. Molar ratios of...
NASA Astrophysics Data System (ADS)
Schoepf, Verena; Levas, Stephen J.; Rodrigues, Lisa J.; McBride, Michael O.; Aschaffenburg, Matthew D.; Matsui, Yohei; Warner, Mark E.; Hughes, Adam D.; Grottoli, Andréa G.
2014-12-01
Coral skeletal δ13C can be a paleo-climate proxy for light levels (i.e., cloud cover and seasonality) and for photosynthesis to respiration (P/R) ratios. The usefulness of coral δ13C as a proxy depends on metabolic isotope effects (related to changes in photosynthesis) being the dominant influence on skeletal δ13C. However, it is also influenced by kinetic isotope effects (related to calcification rate) which can overpower metabolic isotope effects and thus compromise the use of coral skeletal δ13C as a proxy. Heikoop et al. (2000) proposed a simple data correction to remove kinetic isotope effects from coral skeletal δ13C, as well as an equation to calculate P/R ratios from coral isotopes. However, despite having been used by other researchers, the data correction has never been directly tested, and isotope-based P/R ratios have never been compared to P/R ratios measured using respirometry. Experimental coral bleaching represents a unique environmental scenario to test this because bleaching produces large physiological responses that influence both metabolic and kinetic isotope effects in corals. Here, we tested the δ13C correction and the P/R calculation using three Pacific and three Caribbean coral species from controlled temperature-induced bleaching experiments where both the stable isotopes and the physiological variables that cause isotopic fractionation (i.e., photosynthesis, respiration, and calcification) were simultaneously measured. We show for the first time that the data correction proposed by Heikoop et al. (2000) does not effectively remove kinetic effects in the coral species studied here, and did not improve the metabolic signal of bleached and non-bleached corals. In addition, isotope-based P/R ratios were in poor agreement with measured P/R ratios, even when the data correction was applied. This suggests that additional factors influence δ13C and δ18O, which are not accounted for by the data correction. We therefore recommend that the data correction not be routinely applied for paleo-climate reconstruction, and that P/R ratios should only be obtained by direct measurement by respirometry.
Smith, Jennifer A; Sharma, Monisha; Levin, Carol; Baeten, Jared M; van Rooyen, Heidi; Celum, Connie; Hallett, Timothy B; Barnabas, Ruanne V
2015-04-01
Home HIV counselling and testing (HTC) achieves high coverage of testing and linkage to care compared with existing facility-based approaches, particularly among asymptomatic individuals. In a modelling analysis we aimed to assess the effect on population-level health and cost-effectiveness of a community-based package of home HTC in KwaZulu-Natal, South Africa. We parameterised an individual-based model with data from home HTC and linkage field studies that achieved high coverage (91%) and linkage to antiretroviral therapy (80%) in rural KwaZulu-Natal, South Africa. Costs were derived from a linked microcosting study. The model simulated 10,000 individuals over 10 years and incremental cost-effectiveness ratios were calculated for the intervention relative to the existing status quo of facility-based testing, with costs discounted at 3% annually. The model predicted implementation of home HTC in addition to current practice to decrease HIV-associated morbidity by 10–22% and HIV infections by 9–48% with increasing CD4 cell count thresholds for antiretroviral therapy initiation. Incremental programme costs were US$2·7 million to $4·4 million higher in the intervention scenarios than at baseline, and costs increased with higher CD4 cell count thresholds for antiretroviral therapy initiation; antiretroviral therapy accounted for 48–87% of total costs. Incremental cost-effectiveness ratios per disability-adjusted life-year averted were $1340 at an antiretroviral therapy threshold of CD4 count lower than 200 cells per μL, $1090 at lower than 350 cells per μL, $1150 at lower than 500 cells per μL, and $1360 at universal access to antiretroviral therapy. Community-based HTC with enhanced linkage to care can result in increased HIV testing coverage and treatment uptake, decreasing the population burden of HIV-associated morbidity and mortality. The incremental cost-effectiveness ratios are less than 20% of South Africa's gross domestic product per person, and are therefore classed as very cost effective. Home HTC can be a viable means to achieve UNAIDS' ambitious new targets for HIV treatment coverage. National Institutes of Health, Bill & Melinda Gates Foundation, Wellcome Trust.
NASA Astrophysics Data System (ADS)
Blashenkov, N. M.; Sheshenya, E. S.; Solov'ev, S. M.; Sachenko, V. D.; Gall, L. N.; Zarutskii, I. V.; Gall, N. R.
2013-05-01
A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings based on the carbon-13 isotope breath test has been designed and constructed. Important stages of the work included (i) calculating a low-aberration mass analyzer, (ii) manufacturing and testing special gas inlet system, and (iii) creating a small-size collector of ions. The proposed instrument ensures 13C/12C isotopic ratio measurement to within 1.7‰ (pro mille) accuracy, which corresponds to requirements for a diagnostic tool. Preliminary medical testing showed that the mass spectrometer is applicable to practical diagnostics. The instrument is also capable of measuring isotopic ratios of other light elements, including N, O, B (for BF2+ ions), Ar, Cl, and S.
Tofari, Paul J; Cormack, Stuart J; Ebert, Tammie R; Gardner, A Scott; Kemp, Justin G
2017-10-01
Talent identification (TID) and talent development (TDE) programmes in track sprint cycling use ergometer- and track-based tests to select junior athletes and assess their development. The purpose of this study was to assess which tests are best at monitoring TID and TDE. Ten male participants (16.2 ± 1.1 year; 178.5 ± 6.0 cm and 73.6 ± 7.6 kg) were selected into the national TID squad based on initial testing. These tests consisted of two 6-s maximal sprints on a custom-built ergometer and 4 maximal track-based tests (2 rolling and 2 standing starts) using 2 gear ratios. Magnitude-based inferences and correlation coefficients assessed changes following a 3-month TDE programme. Training elicited meaningful improvements (80-100% likely) in all ergometer parameters. The standing and rolling small gear, track-based effort times were likely and very likely (3.2 ± 2.4% and 3.3 ± 1.9%, respectively) improved by training. Stronger correlations between ergometer- and track-based measures were very likely following training. Ergometer-based testing provides a more sensitive tool than track-based testing to monitor changes in neuromuscular function during the early stages of TDE. However, track-based testing can indicate skill-based improvements in performance when interpreted with ergometer testing. In combination, these tests provide information on overall talent development.
NASA Technical Reports Server (NTRS)
Re, R. J.
1974-01-01
An investigation was conducted in the Langley 16-foot transonic tunnel to determine the performance of seven inlets having NACA 1-series contours and one inlet having an elliptical contour over a range of mass-flow ratios and at angle of attack. The inlet diameter ratio varied from 0.81 to 0.89; inlet length ratio varied from 0.75 to 1.25; and internal contraction ratio varied from 1.009 to 1.093. Reynolds number based on inlet maximum diameter varied from 3.4 million at a Mach number of 0.4 to 5.6 million at a Mach number of 1.29.
Experimental rotordynamic coefficient results for honeycomb seals
NASA Technical Reports Server (NTRS)
Elrod, David A.; Childs, Dara W.
1988-01-01
Test results (leakage and rotordynamic coefficients) are presented for seven honeycomb-stator smooth-rotor seals. Tests were carried out with air at rotor speeds up to 16,000 cpm and supply pressures up to 8.2 bars. Test results for the seven seals are compared, and the most stable configuration is identified based on the whirl frequency ratio. Results from tests of a smooth-rotor/smooth-stator seal, a teeth-on-stator labyrinth seal, and the most stable honeycomb seal are compared.
A neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine
NASA Astrophysics Data System (ADS)
Guo, T. H.; Musgrave, J.
1992-11-01
In order to properly utilize the available fuel and oxidizer of a liquid propellant rocket engine, the mixture ratio is closed loop controlled during main stage (65 percent - 109 percent power) operation. However, because of the lack of flight-capable instrumentation for measuring mixture ratio, the value of mixture ratio in the control loop is estimated using available sensor measurements such as the combustion chamber pressure and the volumetric flow, and the temperature and pressure at the exit duct on the low pressure fuel pump. This estimation scheme has two limitations. First, the estimation formula is based on an empirical curve fitting which is accurate only within a narrow operating range. Second, the mixture ratio estimate relies on a few sensor measurements and loss of any of these measurements will make the estimate invalid. In this paper, we propose a neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine. The estimator is an extension of a previously developed neural network based sensor failure detection and recovery algorithm (sensor validation). This neural network uses an auto associative structure which utilizes the redundant information of dissimilar sensors to detect inconsistent measurements. Two approaches have been identified for synthesizing mixture ratio from measurement data using a neural network. The first approach uses an auto associative neural network for sensor validation which is modified to include the mixture ratio as an additional output. The second uses a new network for the mixture ratio estimation in addition to the sensor validation network. Although mixture ratio is not directly measured in flight, it is generally available in simulation and in test bed firing data from facility measurements of fuel and oxidizer volumetric flows. The pros and cons of these two approaches will be discussed in terms of robustness to sensor failures and accuracy of the estimate during typical transients using simulation data.
A neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine
NASA Technical Reports Server (NTRS)
Guo, T. H.; Musgrave, J.
1992-01-01
In order to properly utilize the available fuel and oxidizer of a liquid propellant rocket engine, the mixture ratio is closed loop controlled during main stage (65 percent - 109 percent power) operation. However, because of the lack of flight-capable instrumentation for measuring mixture ratio, the value of mixture ratio in the control loop is estimated using available sensor measurements such as the combustion chamber pressure and the volumetric flow, and the temperature and pressure at the exit duct on the low pressure fuel pump. This estimation scheme has two limitations. First, the estimation formula is based on an empirical curve fitting which is accurate only within a narrow operating range. Second, the mixture ratio estimate relies on a few sensor measurements and loss of any of these measurements will make the estimate invalid. In this paper, we propose a neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine. The estimator is an extension of a previously developed neural network based sensor failure detection and recovery algorithm (sensor validation). This neural network uses an auto associative structure which utilizes the redundant information of dissimilar sensors to detect inconsistent measurements. Two approaches have been identified for synthesizing mixture ratio from measurement data using a neural network. The first approach uses an auto associative neural network for sensor validation which is modified to include the mixture ratio as an additional output. The second uses a new network for the mixture ratio estimation in addition to the sensor validation network. Although mixture ratio is not directly measured in flight, it is generally available in simulation and in test bed firing data from facility measurements of fuel and oxidizer volumetric flows. The pros and cons of these two approaches will be discussed in terms of robustness to sensor failures and accuracy of the estimate during typical transients using simulation data.
21 CFR 862.1455 - Lecithin/sphingomyelin ratio in amniotic fluid test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lecithin/sphingomyelin ratio in amniotic fluid... Clinical Chemistry Test Systems § 862.1455 Lecithin/sphingomyelin ratio in amniotic fluid test system. (a) Identification. A lecithin/sphingomyelin ratio in amniotic fluid test system is a device intended to measure the...
Wight, Vanessa; Kaushal, Neeraj; Waldfogel, Jane; Garfinkel, Irv
2014-01-02
This paper examines the association between poverty and food insecurity among children, using two different definitions of poverty-the official poverty measure (OPM) and the new supplemental poverty measure (SPM) of the Census Bureau, which is based on a more inclusive definition of family resources and needs. Our analysis is based on data from the 2001-11 Current Population Survey and shows that food insecurity and very low food security among children decline as income-to-needs ratio increases. The point estimates show that the associations are stronger as measured by the new supplemental measure of income-to-needs ratio than when estimated through the official measure. Statistical tests reject the hypothesis that poor households' odds of experiencing low food security are the same whether the SPM or OPM measure is used; but the tests do not reject the hypothesis when very low food security is the outcome.
Wight, Vanessa; Kaushal, Neeraj; Waldfogel, Jane; Garfinkel, Irv
2014-01-01
This paper examines the association between poverty and food insecurity among children, using two different definitions of poverty—the official poverty measure (OPM) and the new supplemental poverty measure (SPM) of the Census Bureau, which is based on a more inclusive definition of family resources and needs. Our analysis is based on data from the 2001–11 Current Population Survey and shows that food insecurity and very low food security among children decline as income-to-needs ratio increases. The point estimates show that the associations are stronger as measured by the new supplemental measure of income-to-needs ratio than when estimated through the official measure. Statistical tests reject the hypothesis that poor households’ odds of experiencing low food security are the same whether the SPM or OPM measure is used; but the tests do not reject the hypothesis when very low food security is the outcome. PMID:25045244
Axisymmetric Strain Path Tests on Nellis Baseline Sand
1986-09-01
tested to determine their grain-size distributions, specific gravities , and Atterberg limits. The results of these tests are su-Arized in Table 2.1...plastic limits, plasticity index, and specific gravity . All four batches of NB sand were classified by the Unified Soil Classi- fication System...those contaminated by oil due to membrane leakage. Based on these data and a specific gravity of 2.62, values of dry density, void ratio, degree of
Wolff, Antonio C; Hammond, M Elizabeth Hale; Allison, Kimberly H; Harvey, Brittany E; Mangu, Pamela B; Bartlett, John M S; Bilous, Michael; Ellis, Ian O; Fitzgibbons, Patrick; Hanna, Wedad; Jenkins, Robert B; Press, Michael F; Spears, Patricia A; Vance, Gail H; Viale, Giuseppe; McShane, Lisa M; Dowsett, Mitchell
2018-05-30
- To update key recommendations of the American Society of Clinical Oncology (ASCO)/College of American Pathologists (CAP) human epidermal growth factor receptor 2 (HER2) testing in breast cancer guideline. - Based on the signals approach, an Expert Panel reviewed published literature and research survey results on the observed frequency of less common in situ hybridization (ISH) patterns to update the recommendations. - Two recommendations addressed via correspondence in 2015 are included. First, immunohistochemistry (IHC) 2+ is defined as invasive breast cancer with weak to moderate complete membrane staining observed in >10% of tumor cells. Second, if the initial HER2 test result in a core needle biopsy specimen of a primary breast cancer is negative, a new HER2 test may (not "must") be ordered on the excision specimen based on specific clinical criteria. The HER2 testing algorithm for breast cancer is updated to address the recommended workup for less common clinical scenarios (approximately 5% of cases) observed when using a dual-probe ISH assay. These scenarios are described as ISH group 2 ( HER2/chromosome enumeration probe 17 [CEP17] ratio ≥2.0; average HER2 copy number <4.0 signals per cell), ISH group 3 ( HER2/CEP17 ratio <2.0; average HER2 copy number ≥6.0 signals per cell), and ISH group 4 ( HER2/CEP17 ratio <2.0; average HER2 copy number ≥4.0 and <6.0 signals per cell). The diagnostic approach includes more rigorous interpretation criteria for ISH and requires concomitant IHC review for dual-probe ISH groups 2 to 4 to arrive at the most accurate HER2 status designation (positive or negative) based on combined interpretation of the ISH and IHC assays. The Expert Panel recommends that laboratories using single-probe ISH assays include concomitant IHC review as part of the interpretation of all single-probe ISH assay results.
Current-State Constrained Filter Bank for Wald Testing of Spacecraft Conjunctions
NASA Technical Reports Server (NTRS)
Carpenter, J. Russell; Markley, F. Landis
2012-01-01
We propose a filter bank consisting of an ordinary current-state extended Kalman filter, and two similar but constrained filters: one is constrained by a null hypothesis that the miss distance between two conjuncting spacecraft is inside their combined hard body radius at the predicted time of closest approach, and one is constrained by an alternative complementary hypothesis. The unconstrained filter is the basis of an initial screening for close approaches of interest. Once the initial screening detects a possibly risky conjunction, the unconstrained filter also governs measurement editing for all three filters, and predicts the time of closest approach. The constrained filters operate only when conjunctions of interest occur. The computed likelihoods of the innovations of the two constrained filters form a ratio for a Wald sequential probability ratio test. The Wald test guides risk mitigation maneuver decisions based on explicit false alarm and missed detection criteria. Since only current-state Kalman filtering is required to compute the innovations for the likelihood ratio, the present approach does not require the mapping of probability density forward to the time of closest approach. Instead, the hard-body constraint manifold is mapped to the filter update time by applying a sigma-point transformation to a projection function. Although many projectors are available, we choose one based on Lambert-style differential correction of the current-state velocity. We have tested our method using a scenario based on the Magnetospheric Multi-Scale mission, scheduled for launch in late 2014. This mission involves formation flight in highly elliptical orbits of four spinning spacecraft equipped with antennas extending 120 meters tip-to-tip. Eccentricities range from 0.82 to 0.91, and close approaches generally occur in the vicinity of perigee, where rapid changes in geometry may occur. Testing the method using two 12,000-case Monte Carlo simulations, we found the method achieved a missed detection rate of 0.1%, and a false alarm rate of 2%.
NASA Astrophysics Data System (ADS)
English, Ian; Curet, Oscar
2016-11-01
Lighthill and Blake's 1990 momentum enhancement theory suggests there is a multiplicative propulsive effect linked to the ratio of body and fin heights in Gymnotiform and Balistiform swimmers, which propel themselves using multi-rayed undulating fins while keeping their bodies mostly rigid. Proof of such a momentum enhancement could have a profound effect on unmanned underwater vehicle design and shed light on the evolutionary advantage to body-fin ratios found in nature, shown as optimal for momentum enhancement in Lighthill and Blake's theory. A robotic ribbon fin with twelve independent fin rays, elastic fin membrane, and a body of adjustable height was developed specifically to experimentally test momentum enhancement. Thrust tests for various body heights were conducted in a recirculating flow tank at different flow speeds and fin flapping frequencies. When comparing thrust at different body heights, flow speeds, and frequencies to a 'no-body' thrust test case at each frequency and flow speed, data indicate there is no momentum enhancement factor due to the presence of a body on top of an undulating fin. This suggests that if there is a benefit to a specific ratio between body and fin height, it is not due to momentum enhancement.
Analysis of off-axis tension test of wood specimens
Jen Y. Liu
2002-01-01
This paper presents a stress analysis of the off-axis tension test of clear wood specimens based on orthotropic elasticity theory. The effects of Poisson's ratio and shear coupling coefficient on stress distribution are analyzed in detail. The analysis also provides a theoretical foundation for the selection of a 10° grain angle in wood specimens for the...
Peterson, Mark E; Guterl, Jade N; Rishniw, Mark; Broome, Michael R
2016-07-01
Thyroid scintigraphy is commonly used for evaluation of cats with hyperthyroidism, with the thyroid-to-salivary ratio (T/S) being the most common method to quantify the degree of thyroid activity and disease. Calculation of thyroid-to-background ratios (T/B) or percent thyroidal uptake of (99m) TcO(-) 4 (TcTU) has only been reported in a few studies. The purpose of this prospective, cross-sectional study was to evaluate a number of quantitative scintigraphic indices as diagnostic tests for hyperthyroidism, including the T/S, three different T/B, TcTU, and estimated thyroid volume. Of 524 cats referred to our clinic for evaluation of suspected hyperthyroidism, the diagnosis was confirmed (n = 504) or excluded (n = 20) based on results of a serum thyroid panel consisting of thyroxine (T4 ), triiodothyronine (T3 ), free T4 (fT4 ), and thyroid-stimulating hormone (TSH) concentrations. In the hyperthyroid cats, median values for TcTU, T/S, and three T/B ratios were all significantly higher (P < 0.001) than values in euthyroid suspect cats or clinically normal cats. All scintigraphic parameters were relatively sensitive and specific as diagnostic tests for hyperthyroidism, but the T/S ratio had the highest test accuracy. The T/S ratio correlated strongly with the TcTU (r = 0.85). However, the TcTU had a higher and more significant correlation (P < 0.01) with serum T4 (r = 0.76 vs. 0.64), T3 (r = 0.77 vs. 0.64), and estimated thyroid volume (r = 0.62 vs. 0.38). Overall, calculation of TcTU is an accurate diagnostic test, but also appears to be the best parameter to predict the functional volume and metabolic activity of the feline adenomatous thyroid gland. © 2016 American College of Veterinary Radiology.
Parametric test results of a swirl-can combustor
NASA Technical Reports Server (NTRS)
Niedzwiecki, R. W.; Jones, R. E.
1973-01-01
Pollutant levels of oxides of nitrogen, unburned hydrocarbons, and carbon monoxide were measured for three models of an experimental, annular swirl can combustor. The combustor was 1.067 meters in outer diameter, incorporated 120 modules, and was specifically designed for elevated exit temperature performance. Test conditions included combustor inlet temperatures of 589, 756 and 839 K, inlet pressures of 3 to 6.4 atmospheres, reference velocities of 21 to 38 meters per second and combustor equivalence ratios, based on total combustor flows of 0.206 to 1.028. Maximum oxides of nitrogen emission index values occurred at an equivalence ratio of 0.7 with lower values measured for both higher and lower equivalence ratios. Oxides of nitrogen concentrations, to the 0.7 level with 756 K inlet air, were correlated for the three models by a combined parameter consisting of measured flow and geometric parameters. Effects of the individual parameters comprising the correlation are also presented.
Mechanical behaviour study on SBR/EVA composite for FDM feedstock fabrication
NASA Astrophysics Data System (ADS)
Raveverma, P.; Ibrahim, M.; Sa'ude, N.; Yarwindran, M.; Nasharuddin, M.
2017-04-01
This paper presents the research development of a new SBR/EVA composite flexible feedstock material by the injection moulding machine. The material consists of poly (ethylene-co-vinyl acetate) in styrene butadiene rubber cross-linked by Dicumyl Peroxide. In this study, the mechanical behaviour of injection moulded SBR/EVA composite with different blend ratio investigated experimentally. The formulations of blend ratio with several combinations of a new SBR/EVA flexible feedstock was done by volume percentage (vol. %). Based on the result obtained from the mechanical testing done which is tensile and hardness the composite of SBR/EVA has the high potency to be fabricated as the flexible filament feedstock. The ratio of 80:20 which as an average hardness and tensile strength proved to be the suitable choice to be fabricated as the flexible filament feedstock. The study has reached its goals on the fabricating and testing a new PMC which is flexible.
Lovich, Jeffrey E.; Gibbons, J. Whitfield; Agha, Mickey
2014-01-01
The attainment of sexual maturity has been shown to affect measures of sexual size dimorphism (SSD) and adult sex ratios in several groups of vertebrates. Using data for turtles, we tested the model that sex ratios are expected to be male-biased when females are larger than males and female-biased when males are larger than females because of the relationship of each with the attainment of maturity. Our model is based on the premise that the earlier-maturing sex remains smaller, on average throughout life, and predominates numerically unless the sexes are strongly affected by differential mortality, differential emigration, and immigration, or biased primary sex ratios. Based on data for 24 species in seven families, SSD and sex ratios were significantly negatively correlated for most analyses, even after the effect of phylogenetic bias was removed. The analyses provide support for the model that SSD and adult sex ratios are correlated in turtles as a result of simultaneous correlation of each with sexual differences in attainment of maturity (bimaturism). Environmental sex determination provides a possible mechanism for the phenomenon in turtles and some other organisms.
Likelihood ratios for glaucoma diagnosis using spectral-domain optical coherence tomography.
Lisboa, Renato; Mansouri, Kaweh; Zangwill, Linda M; Weinreb, Robert N; Medeiros, Felipe A
2013-11-01
To present a methodology for calculating likelihood ratios for glaucoma diagnosis for continuous retinal nerve fiber layer (RNFL) thickness measurements from spectral-domain optical coherence tomography (spectral-domain OCT). Observational cohort study. A total of 262 eyes of 187 patients with glaucoma and 190 eyes of 100 control subjects were included in the study. Subjects were recruited from the Diagnostic Innovations Glaucoma Study. Eyes with preperimetric and perimetric glaucomatous damage were included in the glaucoma group. The control group was composed of healthy eyes with normal visual fields from subjects recruited from the general population. All eyes underwent RNFL imaging with Spectralis spectral-domain OCT. Likelihood ratios for glaucoma diagnosis were estimated for specific global RNFL thickness measurements using a methodology based on estimating the tangents to the receiver operating characteristic (ROC) curve. Likelihood ratios could be determined for continuous values of average RNFL thickness. Average RNFL thickness values lower than 86 μm were associated with positive likelihood ratios (ie, likelihood ratios greater than 1), whereas RNFL thickness values higher than 86 μm were associated with negative likelihood ratios (ie, likelihood ratios smaller than 1). A modified Fagan nomogram was provided to assist calculation of posttest probability of disease from the calculated likelihood ratios and pretest probability of disease. The methodology allowed calculation of likelihood ratios for specific RNFL thickness values. By avoiding arbitrary categorization of test results, it potentially allows for an improved integration of test results into diagnostic clinical decision making. Copyright © 2013. Published by Elsevier Inc.
Luttmer, Roosmarijn; Berkhof, Johannes; Dijkstra, Maaike G; van Kemenade, Folkert J; Snijders, Peter J F; Heideman, Daniëlle A M; Meijer, Chris J L M
2015-06-01
High-risk human papillomavirus (hrHPV) DNA positive women require triage testing to identify those with high-grade cervical intraepithelial neoplasia or cancer (≥CIN2). Comparing three triage algorithms (1) E7 mRNA testing following HPV16/18/31/33/45/52/58 genotyping (E7 mRNA test), (2) HPV16/18 DNA genotyping and (3) cytology, for ≥CIN2 detection in hrHPV DNA-positive women. hrHPV DNA-positive women aged 18-63 years visiting gynecology outpatient clinics were included in a prospective observational cohort study. From these women a cervical scrape and colposcopy-directed biopsies were obtained. Cervical scrapes were evaluated by cytology, HPV DNA genotyping by bead-based multiplex genotyping of GP5+6+-PCR-products, and presence of HPV16/18/31/33/45/52/58 E7 mRNA using nucleic acid sequence-based amplification (NASBA) in DNA positive women for respective HPV types. Sensitivities and specificities for ≥CIN2 were compared between E7 mRNA test and HPV16/18 DNA genotyping in the total group (n=348), and E7 mRNA test and cytology in a subgroup of women referred for non-cervix-related gynecological complaints (n=133). Sensitivity for ≥CIN2 of the E7 mRNA test was slightly higher than that of HPV16/18 DNA genotyping (66.9% versus 60.9%; ratio 1.10, 95% CI: 1.0002-1.21), at similar specificity (54.8% versus 52.3%; ratio 1.05, 95% CI: 0.93-1.18). Neither sensitivity nor specificity of the E7 mRNA test differed significantly from that of cytology (sensitivity: 68.8% versus 75.0%; ratio 0.92, 95% CI: 0.72-1.17; specificity: 59.4% versus 65.3%; ratio 0.91, 95% CI: 0.75-1.10). For detection of ≥CIN2 in hrHPV DNA-positive women, an algorithm including E7 mRNA testing following HPV16/18/31/33/45/52/58 DNA genotyping performs similar to HPV16/18 DNA genotyping or cytology. Copyright © 2015 Elsevier B.V. All rights reserved.
Fatigue Characterization of Alloy 10: a 1300F Disk Alloy for Small Gas Turbine Engines
NASA Technical Reports Server (NTRS)
Gayda, John
2000-01-01
A detailed fatigue characterization of Alloy 10, a high strength nickel-based disk alloy, was conducted on test coupons machined from a 'pancake' forging. Smooth bar, strain controlled fatigue testing at various R-ratios was run at representative bore, 750 F, and rim, 1300 F, temperatures. This was followed by notch fatigue testing (Kt=2) run under load control. Analysis of the fatigue data using a Smith-Watson-Topper approach and finite element analysis of the notch root was employed to understand material behavior in these tests. Smooth bar fatigue data showed a significant R-ratio dependence at either test temperature which could be accounted for using a Smith-Watson-Topper parameter (SWT). In general, fatigue life was longer at 750 F than 1300 F for a given SWT. For notch fatigue tests, life was longer at 750 F than 1300 F but only at higher stresses. This was attributed to differences in alloy strength. At lower stresses, finite element analysis suggested that convergence of fatigue life at both temperatures resulted from relaxation of stresses at the notch root in the 1300 F tests.
Sargent, A.; Bailey, A.; Turner, A.; Almonte, M.; Gilham, C.; Baysson, H.; Peto, J.; Roberts, C.; Thomson, C.; Desai, M.; Mather, J.; Kitchener, H.
2010-01-01
We present data on the use of the Hybrid Capture 2 (HC2) test for the detection of high-risk human papillomavirus (HR HPV) with different thresholds for positivity within a primary screening setting and as a method of triage for low-grade cytology. In the ARTISTIC population-based trial, 18,386 women were screened by cytology and for HPV. Cervical intraepithelial neoplasia lesions of grade two and higher (CIN2+ lesions) were identified for 453 women within 30 months of an abnormal baseline sample. When a relative light unit/cutoff (RLU/Co) ratio of ≥1 was used as the threshold for considering an HC2 result positive, 15.6% of results were positive, and the proportion of CIN2+ lesions in this group was 14.7%. The relative sensitivity for CIN2+ lesion detection was 93.4%. When an RLU/Co ratio of ≥2 was used as the threshold, there was a 2.5% reduction in positivity, with an increase in the proportion of CIN2+ lesions detected. The relative sensitivity decreased slightly, to 90.3%. Among women with low-grade cytology, HPV prevalences were 43.7% and 40.3% at RLU/Co ratios of ≥1 and ≥2, respectively. The proportions of CIN2+ lesions detected were 17.3% and 18.0%, with relative sensitivities of 87.7% at an RLU/Co ratio of ≥1 and 84.2% at an RLU/Co ratio of ≥2. At an RLU/Co ratio of ≥1, 68.3% of HC2-positive results were confirmed by the Roche line blot assay, compared to 77.2% of those at an RLU/Co ratio of ≥2. Fewer HC2-positive results were confirmed for 35- to 64-year-olds (50.3% at an RLU/Co ratio of ≥1 and 63.2% at an RLU/Co ratio of >2) than for 20- to 34-year-olds (78.7% at an RLU/Co ratio of ≥1 and 83.7% at an RLU/Co ratio of >2). If the HC2 test is used for routine screening as an initial test or as a method of triage for low-grade cytology, we would suggest increasing the threshold for positivity from the RLU/Co ratio of ≥1, recommended by the manufacturer, to an RLU/Co ratio of ≥2, since this study has shown that a beneficial balance between relative sensitivity and the proportion of CIN2+ lesions detected is achieved at this threshold. PMID:20007387
Kemençe, Nevsal; Bölgen, Nimet
2017-01-01
The aim of this study was the synthesis and characterization of gelatin- and hydroxyapatite (osteoconductive component of bone)-based cryogels for tissue-engineering applications. Preliminary in vitro and in vivo biocompatibility tests were conducted. Gelatin- and hydroxyapatite-based cryogels of varying concentrations were synthesized using glutaraldehyde as the crosslinking agent. Chemical structure, pore morphology, pore size distribution, mechanical properties, swelling characteristics and degradation profiles of the synthesized cryogels were demonstrated by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), mercury porosimetry, a mechanical test device, swelling ratio tests and weight loss measurements, respectively. In vitro cell viability and in vivo biocompatility tests were performed in order to show the performance of the cryogels in the biological environment. Changing the concentrations of gelatin, hydroxyapatite and crosslinker changed the chemical structure, pore size and pore size distribution of the cryogels, which in turn resulted in the ultimate behaviour (mechanical properties, swelling ratio, degradation profile). In vitro cell culture tests showed the viability of the cells. The cryogels did not show any cytotoxic effects on the cells. Clinical outcomes and the gross pathological results demonstrated that there was no necrosis noted in the abdominal and thoracic regions at the end of implantation and the implanted cryogel was found to be non-irritant and non-toxic at 12 weeks of implantation. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.
Basic numerical capacities and prevalence of developmental dyscalculia: the Havana Survey.
Reigosa-Crespo, Vivian; Valdés-Sosa, Mitchell; Butterworth, Brian; Estévez, Nancy; Rodríguez, Marisol; Santos, Elsa; Torres, Paul; Suárez, Ramón; Lage, Agustín
2012-01-01
The association of enumeration and number comparison capacities with arithmetical competence was examined in a large sample of children from 2nd to 9th grades. It was found that efficiency on numerical capacities predicted separately more than 25% of the variance in the individual differences on a timed arithmetical test, and this occurred for both younger and older learners. These capacities were also significant predictors of individual variations in an untimed curriculum-based math achievement test and on the teacher scores of math performance over developmental time. Based on these findings, these numerical capacities were used for estimating the prevalence and gender ratio of basic numerical deficits and developmental dyscalculia (DD) over the grade range defined above (N = 11,652 children). The extent to which DD affects the population with poor ability on calculation was also examined. For this purpose, the prevalence and gender ratio of arithmetical dysfluency (AD) were estimated in the same cohort. The estimated prevalence of DD was 3.4%, and the male:female ratio was 4:1. However, the prevalence of AD was almost 3 times as high (9.35%), and no gender differences were found (male:female ratio = 1.07:1). Basic numerical deficits affect 4.54% of school-age population and affect more boys than girls (2.4:1). The differences between the corresponding estimates were highly significant (α < .01). Based on these contrastive findings, it is concluded that DD, defined as a defective sense of numerosity, could be a distinctive disorder that affects only a portion of children with AD.
[Quantitative studies on reversible thrombocyte aggregation during exertion].
Haber, P; Silberbauer, K; Sinzinger, H
1980-10-11
In 8 oarsmen aged 19 to 31 years a symptom-limited rectangular-progressive bicycle stress test has been conducted. Venous blood was taken before and at the end of the test, and 30 and 60 minutes afterwards. pH, base excess, pCO2, platelet count and platelet count ratio (WU and HOAK) were measured or calculated, the last in order to quantify the tendency of the platelets to form reversible aggregates. At the point of exhaustion there is a highly significant (p < 0.001) decrease in the platelet cunt ratio (= increase in reversible platelet aggregates). A highly significant correlation exists between base excess and the platelet count ratio. The regression line does not fall below the normal value of the platelet count ratio until the delta-base excess is -4 mval/l. This means that an increase in the tendency to form reversible platelet aggregates is not typical of the range of aerobic metabolism but of muscular work in the anaerobic range with high exercise-induced metabolic acidosis. The basis for sudden death in sport due to internal reasons is not uncommonly an unknown and asymptomatic coronary disease and platelet aggregates. Persons aged over 30 years and sports in which competition is also inherent (soccer, tennis) are often involved. Acute cardiac death in sport is not very frequent. Nevertheless, the following recomendation seems to be warranted: persons aged over 30 years in bad condition should not start competitive sports or other intensive muscular exercise. Before they do so, low-intensive, controlled, aerobic endurance training is necessary.
NASA Technical Reports Server (NTRS)
Balakrishna, S.; Kilgore, W. Allen; Murthy, A. V.
1989-01-01
A performance evaluation of an active sidewall boundary-layer removal system for the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) was evaluated in 1988. This system uses a compressor and two throttling digital valves to control the boundary-layer mass flow removal from the tunnel. The compressor operates near the maximum pressure ratio for all conditions. The system uses a surge prevention and flow recirculation scheme. A microprocessor based controller is used to provide the necessary mass flow and compressor pressure ratio control. Initial tests on the system indicated problems in realizing smooth mass flow control while running the compressor at high speed and high pressure ratios. An alternate method has been conceived to realize boundary-layer mass flow control which avoids the recirculation of the compressor mass flow and operation near the compressor surge point. This scheme is based on varying the speed of the compressor for a sufficient pressure ratio to provide needed mass flow removal. The system has a mass flow removal capability of about 10 percent of test section flow at M = 0.3 and 4 percent at M = 0.8. The system performance has been evaluated in the form of the compressor map, and compressor tunnel interface characteristics covering most of the 0.3-m TCT operational envelope.
NASA Astrophysics Data System (ADS)
Seager, David J.; Liburdy, James A.
1997-11-01
To further understand the effect of both compound angle holes and hole shaping on film cooling, detailed heat transfer measurements were obtained using hue based thermochromic liquid crystal method. The data were analyzed to measure both the full surface adiabatic effectiveness and heat transfer coefficient. The compound angles that were evaluated consist of holes that were aligned 0 degrees, 45 degrees, 60 degrees and 90 degrees to the main cross flow direction. Hole shaping variations from the traditional cylindrical shaped hole include forward diffused and laterally diffused hole geometries. Geometric parameters that were selected were the length to diameter ratio of 3.0, and the inclination angle 35 degrees. A density ratio of 1.55 was obtained for all teste. For each set of conditions the blowing ratio was varied to be 0.88, 1.25, and 1.88. Adiabatic effectiveness was obtained using a steady state test, while an active heating surface was used to determine the heat transfer coefficient using a transient method. The experimental method provides a unique method of analyzing a three-temperature heat transfer problem by providing detailed surface transport properties. Based on these results for the different hole geometries at each blowing ratio conclusions are drawn relative to the effects of compound angle holes on the overall film cooling performance.
NASA Technical Reports Server (NTRS)
Flynn, Michael; Shaw, Hali; Hyde, Deirdre; Beeler, David; Parodi, Jurek
2015-01-01
The Forward Osmosis Brine Drying (FOBD) system is based on a technique called forward osmosis (FO). FO is a membrane-based process where the osmotic potential between brine and a salt solution is equalized by the movement of water from the brine to the salt solution. The FOBD system is composed of two main elements, the FO bag and the salt regeneration system. This paper discusses the results of testing of the FO bag to determine the maximum water recovery ratio that can be attained using this technology. Testing demonstrated that the FO bag is capable of achieving a maximum brine water recovery ratio of the brine of 95%. The equivalent system mass was calculated to be 95 kg for a feed similar to the concentrated brine generated on the International Space Station and 86 kg for an Exploration brine. The results have indicated that the FOBD can process all the brine for a one year mission for between 11% to 10% mass required to bring the water needed to make up for water lost in the brine if not recycled. The FOBD saves 685 kg and when treating the International Space Station brine and it saves 829 kg when treating the Exploration brine. It was also demonstrated that saturated salt solutions achieve a higher water recovery ratios than solids salts do and that lithium chloride achieved a higher water recovery ratio than sodium chloride.
Homoepitaxial growth of non-polar AlN crystals using molecular dynamics simulations
NASA Astrophysics Data System (ADS)
Leathersich, Jeff; Suvarna, Puneet; Tungare, Mihir; Shahedipour-Sandvik, F. (Shadi)
2013-11-01
Homoepitaxial growth of AlN on (11-20) a-plane and (1-100) m-plane under varying deposition temperatures and aluminum to nitrogen flux ratios was carried out using molecular dynamics (MD) simulations with a Tersoff based interatomic potential. The results indicate that much thicker overgrown films are obtained on m-plane as compared to the a-plane, for the same temperature, N:Al flux, and number of precursor atoms. Crystallinity of the depositions improves as the temperature is increased above 1000 K, accompanied with a better stoichiometry due to increased adatom mobility. Improvement in crystal quality with a N:Al ratio greater than 1 is seen because N atoms desorb more easily than Al atoms. Increasing the N:Al ratio too high limits Al adatom mobility as well as causes site blocking for Al atoms and degrades the deposition quality. The optimum value for N:Al flux ratio was found to be between 1.2 and 1.8 for the deposition temperatures tested based on crystallinity and stoichiometry.
An improved multi-paths optimization method for video stabilization
NASA Astrophysics Data System (ADS)
Qin, Tao; Zhong, Sheng
2018-03-01
For video stabilization, the difference between original camera motion path and the optimized one is proportional to the cropping ratio and warping ratio. A good optimized path should preserve the moving tendency of the original one meanwhile the cropping ratio and warping ratio of each frame should be kept in a proper range. In this paper we use an improved warping-based motion representation model, and propose a gauss-based multi-paths optimization method to get a smoothing path and obtain a stabilized video. The proposed video stabilization method consists of two parts: camera motion path estimation and path smoothing. We estimate the perspective transform of adjacent frames according to warping-based motion representation model. It works well on some challenging videos where most previous 2D methods or 3D methods fail for lacking of long features trajectories. The multi-paths optimization method can deal well with parallax, as we calculate the space-time correlation of the adjacent grid, and then a kernel of gauss is used to weigh the motion of adjacent grid. Then the multi-paths are smoothed while minimize the crop ratio and the distortion. We test our method on a large variety of consumer videos, which have casual jitter and parallax, and achieve good results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, Paul S.; Keenan, Russell E.; Swartout, Jeffrey C.
For most chemicals, the Reference Dose (RfD) is based on data from animal testing. The uncertainty introduced by the use of animal models has been termed interspecies uncertainty. The magnitude of the differences between the toxicity of a chemical in humans and test animals and its uncertainty can be investigated by evaluating the inter-chemical variation in the ratios of the doses associated with similar toxicological endpoints in test animals and humans. This study performs such an evaluation on a data set of 64 anti-neoplastic drugs. The data set provides matched responses in humans and four species of test animals: mice,more » rats, monkeys, and dogs. While the data have a number of limitations, the data show that when the drugs are evaluated on a body weight basis: 1) toxicity generally increases with a species' body weight; however, humans are not always more sensitive than test animals; 2) the animal to human dose ratios were less than 10 for most, but not all, drugs; 3) the current practice of using data from multiple species when setting RfDs lowers the probability of having a large value for the ratio. These findings provide insight into inter-chemical variation in animal to human extrapolations and suggest the need for additional collection and analysis of matched toxicity data in humans and test animals.« less
Bressy, C; Hellio, C; Marechal, J P; Tanguy, B; Margaillan, A
2010-10-01
This paper focuses on the activity spectrum of three dimethylalkyl tertiary amines as potential active molecules and the corresponding ammonium salt-based antifouling (AF) paints. Bioassays (using marine bacteria, microalgae and barnacles) and field tests were combined to assess the AF activity of coatings. Bioassay results demonstrated that the ammonium salt-based paints did not inhibit the growth of microorganisms (except the dimethyldodecylammonium-based coatings) and that the tertiary amines were potent towards bacteria, diatoms, and barnacle larvae at non-toxic concentrations (therapeutic ratio, LC50/EC50, <1). The results from field tests indicated that the ammonium salt-based coatings inhibited the settlement of macrofouling and the dimethylhexadecylammonium-based coatings provided protection against slime in comparison with PVC blank panels. Thus, results from laboratory assays did not fully concur with the AF activity of the paints in the field trial.
Experimental Study on Fatigue Performance of Foamed Lightweight Soil
NASA Astrophysics Data System (ADS)
Qiu, Youqiang; Yang, Ping; Li, Yongliang; Zhang, Liujun
2017-12-01
In order to study fatigue performance of foamed lightweight soil and forecast its fatigue life in the supporting project, on the base of preliminary tests, beam fatigue tests on foamed lightweight soil is conducted by using UTM-100 test system. Based on Weibull distribution and lognormal distribution, using the mathematical statistics method, fatigue equations of foamed lightweight soil are obtained. At the same time, according to the traffic load on real road surface of the supporting project, fatigue life of formed lightweight soil is analyzed and compared with the cumulative equivalent axle loads during the design period of the pavement. The results show that even the fatigue life of foamed lightweight soil has discrete property, the linear relationship between logarithmic fatigue life and stress ratio still performs well. Especially, the fatigue life of Weibull distribution is more close to that derived from the lognormal distribution, in the instance of 50% guarantee ratio. In addition, the results demonstrated that foamed lightweight soil as subgrade filler has good anti-fatigue performance, which can be further adopted by other projects in the similar research domain.
Application-Oriented Chemical Optimization of a Metakaolin Based Geopolymer
Ferone, Claudio; Colangelo, Francesco; Roviello, Giuseppina; Asprone, Domenico; Menna, Costantino; Balsamo, Alberto; Prota, Andrea; Cioffi, Raffaele; Manfredi, Gaetano
2013-01-01
In this study the development of a metakaolin based geopolymeric mortar to be used as bonding matrix for external strengthening of reinforced concrete beams is reported. Four geopolymer formulations have been obtained by varying the composition of the activating solution in terms of SiO2/Na2O ratio. The obtained samples have been characterized from a structural, microstructural and mechanical point of view. The differences in structure and microstructure have been correlated to the mechanical properties. A major issue of drying shrinkage has been encountered in the high Si/Al ratio samples. In the light of the characterization results, the optimal geopolymer composition was then applied to fasten steel fibers to reinforced concrete beams. The mechanical behavior of the strengthened reinforced beams was evaluated by four-points bending tests, which were performed also on reinforced concrete beams as they are for comparison. The preliminary results of the bending tests point out an excellent behavior of the geopolymeric mixture tested, with the failure load of the reinforced beams roughly twice that of the control beam. PMID:28809251
Support vector regression methodology for estimating global solar radiation in Algeria
NASA Astrophysics Data System (ADS)
Guermoui, Mawloud; Rabehi, Abdelaziz; Gairaa, Kacem; Benkaciali, Said
2018-01-01
Accurate estimation of Daily Global Solar Radiation (DGSR) has been a major goal for solar energy applications. In this paper we show the possibility of developing a simple model based on the Support Vector Regression (SVM-R), which could be used to estimate DGSR on the horizontal surface in Algeria based only on sunshine ratio as input. The SVM model has been developed and tested using a data set recorded over three years (2005-2007). The data was collected at the Applied Research Unit for Renewable Energies (URAER) in Ghardaïa city. The data collected between 2005-2006 are used to train the model while the 2007 data are used to test the performance of the selected model. The measured and the estimated values of DGSR were compared during the testing phase statistically using the Root Mean Square Error (RMSE), Relative Square Error (rRMSE), and correlation coefficient (r2), which amount to 1.59(MJ/m2), 8.46 and 97,4%, respectively. The obtained results show that the SVM-R is highly qualified for DGSR estimation using only sunshine ratio.
Temporal spectral response of a corn canopy
NASA Technical Reports Server (NTRS)
Markham, B. L.; Kimes, D. S.; Tucker, C. J.; Mcmurtrey, J. E., III
1981-01-01
Techniques developed for the prediction of winter wheat yields from remotely sensed data indicating crop status over the growing season are tested for their applicability to corn. Ground-based spectral measurements in the Landsat Thematic Mapper bands 3 (0.62-0.69 microns), 4 (0.76-0.90 microns) and 5 (1.55-1.75 microns) were performed at one-week intervals throughout the growing season for 24 plots of corn, and analyzed to derive spectral ratios and normalized spectral differences of the IR and shortwave IR bands with the red. The ratios of the near IR and shortwave IR bands are found to provide the highest and most consistent correlations with corn yield and dry matter accumulation, however the value of band 5 could not be tested due to the absence of water stress conditions. Integration of spectral ratios over several dates improved the correlations over those of any single date by achieving a seasonal, rather than instantaneous, estimate of crop status. Results point to the desirability of further tests under other growth conditions to determine whether satellite-derived data will be useful in providing corn yield information.
Chiu, Haw-Yen; Hsu, Hsiu-Yun; Kuo, Li-Chieh; Chang, Jer-Hao; Su, Fong-Chin
2009-08-01
A precise magnitude and timing control of pinch performance is based on accurate feed-forward and feedback control mechanisms. Ratio of peak pinch force and maximum load force during a functional performance is a sensitive parameter to reflect the ability to scale pinch force output according to actual loads. A pinch apparatus was constructed to detect momentary pinch force modulation of 20 subjects with normal hand sensation. The results indicated high intra-class correlation coefficient and small coefficient of variation of the detected force ratio among three repeated tests, which represented that the stability test of the measured response confirmed the feasibility of this apparatus. The force ratio for a 480 g object with a steel surface ranged between 1.77 and 1.98. Normal subjects were able to scale and contribute pinch force precisely to a pinch-holding-up test. This study may provide clinicians a reliable apparatus and method to analyze the recovery of functional sensibility in patients with nerve injuries. Copyright 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Flavour and identification threshold detection overview of Slovak adepts for certified testing.
Vietoris, VladimIr; Barborova, Petra; Jancovicova, Jana; Eliasova, Lucia; Karvaj, Marian
2016-07-01
During certification process of sensory assessors of Slovak certification body we obtained results for basic taste thresholds and lifestyle habits. 500 adult people were screened during experiment with food industry background. For analysis of basic and non basic tastes, we used standardized procedure of ISO 8586-1:1993. In flavour test experiment, group of (26-35 y.o) produced the lowest error ratio (1.438), highest is (56+ y.o.) group with result (2.0). Average error value based on gender for women was (1.510) in comparison to men (1.477). People with allergies have the average error ratio (1.437) in comparison to people without allergies (1.511). Non-smokers produced less errors (1.484) against the smokers (1.576). Another flavour threshold identification test detected differences among age groups (by age are values increased). The highest number of errors made by men in metallic taste was (24%) the same as made by women (22%). Higher error ratio made by men occurred in salty taste (19%) against women (10%). Analysis detected some differences between allergic/non-allergic, smokers/non-smokers groups.
[Point-of-Care Testing in Trauma Patients - Methods and Evidence].
Dirkmann, Daniel; Britten, Martin W; Frey, Ulrich H
2018-06-01
In severely injured patients, trauma-induced coagulopathy (TIC) present at hospital admission is associated with increased transfusion requirements, morbidity and mortality. Early and effective treatment contributes to improved survival rates. Laboratory coagulation assays have long turn-around times and evidence for their usefulness, especially in the context of TIC, is weak. Due to the lack of appropriate guidance, transfusion of allogeneic blood products frequently follows a ratio-based concept (e.g., transfusion of erythrocytes and plasma in a 1 : 1 ratio). Point-of-care (PoC) tests enable the assessment of prothrombin time (PT) and activated partial thromboplastin time in few minutes. However, although normal PT in these tests allows to rule out relevant effects of several anticoagulants, they are not able to detect patients with TIC and/or requiring subsequent massive transfusion. Viscoelastic tests (VETs) make it possible to assess defects in thrombin generation, hypofibrinogenaemia, thrombocytopenia, and hyperfibrinolysis, and thus enable targeted therapy. Impairment of platelet function is the common blind spot not detectable using both standard laboratory-based tests and VETs. However, PoC platelet function tests enable to detect platelet defects and patients taking anti-platelet. Furthermore, impaired platelet function has been identified as a strong predictor for coagulopathy and massive transfusion in trauma patients. In other clinical settings, coagulation management based on VETs is associated with decreased transfusion requirements, incidence of acute kidney failure, and mortality, respectively. Data of the first small prospective randomised trial indicate superiority of VET guided coagulation management solely using coagulation factor concentrates, when compared to plasma transfusions in severe trauma. Georg Thieme Verlag KG Stuttgart · New York.
The continuum fusion theory of signal detection applied to a bi-modal fusion problem
NASA Astrophysics Data System (ADS)
Schaum, A.
2011-05-01
A new formalism has been developed that produces detection algorithms for model-based problems, in which one or more parameter values is unknown. Continuum Fusion can be used to generate different flavors of algorithm for any composite hypothesis testing problem. The methodology is defined by a fusion logic that can be translated into max/min conditions. Here it is applied to a simple sensor fusion model, but one for which the generalized likelihood ratio test is intractable. By contrast, a fusion-based response to the same problem can be devised that is solvable in closed form and represents a good approximation to the GLR test.
Design and test of a prototype scale ejector wing
NASA Technical Reports Server (NTRS)
Mefferd, L. A.; Alden, R. E.; Bevilacqua, P. M.
1979-01-01
A two dimensional momentum integral analysis was used to examine the effect of changing inlet area ratio, diffuser area ratio, and the ratio of ejector length to width. A relatively wide range of these parameters was considered. It was found that for constant inlet area ratio the augmentation increases with the ejector length, and for constant length: width ratio the augmentation increases with inlet area ratio. Scale model tests were used to verify these trends and to examine th effect of aspect ratio. On the basis of these results, an ejector configuration was selected for fabrication and testing at a scale representative of an ejector wing aircraft. The test ejector was powered by a Pratt-Whitney F401 engine developing approximately 12,000 pounds of thrust. The results of preliminary tests indicate that the ejector develops a thrust augmentation ratio better than 1.65.
Relative sliding durability of candidate high temperature fiber seal materials
NASA Technical Reports Server (NTRS)
Dellacorte, Christopher; Steinetz, Bruce M.
1992-01-01
The relative sliding durability behavior of six candidate ceramic fibers for high temperature sliding seal applications is reviewed and compared. Pin on disk tests were used to evaluate potential seal materials by sliding a tow or bundle of the candidate ceramic fiber against a superalloy test disk. Tests were conducted in air under a 2.65 N load, at a sliding velocity of 0.025 m/sec and at temperatures from 25 to 900 C. Friction was measured during the tests and fiber wear, indicated by the extent of fibers broken in the tow or bundle, was measured at the end of each test. For most of the fibers, friction and wear increase with test temperature. The relative fiber durability ranking correlates with tensile strength, indicating that tensile data, which is more readily available than sliding durability data, may be useful in predicting fiber wear behavior under various conditions. A dimensional analysis of the wear data shows that the fiber durability is related to a dimensionless durability ratio which represents the ratio of the fiber strength to the fiber stresses imposed by sliding. The analysis is applicable to fibers with similar diameters and elastic moduli. Based upon the results of the research program, three fiber candidates are recommended for further study as potential seal materials. They are a silicon based complex carbide-oxide fiber, an alumina-boria-silica and an aluminosilicate fiber.
A novel approach for small sample size family-based association studies: sequential tests.
Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan
2011-08-01
In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.
GPU-accelerated phase extraction algorithm for interferograms: a real-time application
NASA Astrophysics Data System (ADS)
Zhu, Xiaoqiang; Wu, Yongqian; Liu, Fengwei
2016-11-01
Optical testing, having the merits of non-destruction and high sensitivity, provides a vital guideline for optical manufacturing. But the testing process is often computationally intensive and expensive, usually up to a few seconds, which is sufferable for dynamic testing. In this paper, a GPU-accelerated phase extraction algorithm is proposed, which is based on the advanced iterative algorithm. The accelerated algorithm can extract the right phase-distribution from thirteen 1024x1024 fringe patterns with arbitrary phase shifts in 233 milliseconds on average using NVIDIA Quadro 4000 graphic card, which achieved a 12.7x speedup ratio than the same algorithm executed on CPU and 6.6x speedup ratio than that on Matlab using DWANING W5801 workstation. The performance improvement can fulfill the demand of computational accuracy and real-time application.
Remote sensing of soils in the eastern Palouse region with Landsat Thematic Mapper
NASA Technical Reports Server (NTRS)
Frazier, B. E.; Cheng, Yaan
1989-01-01
Soils of the Palouse region of eastern Washington State were investigated using Landsat Thematic Mapper (TM) band ratios to discriminate areas where erosion has caused paleosols to be exposed. Ratioed data were clustered and plotted to show soil lines which could be subdivided into various levels of organic matter and iron oxides. Successfully classified scenes of a summer fallow (bare soil) field were obtained with band ratios 1/4, 3/4, and 5/4 to map organic carbon and 3/4, 5/4, and 5/3 for the iron/carbon ratio indicator of erosion. Regression models were made with 5/4 data and organic carbon and 5/3 data and the iron/carbon ratio. Based on this analysis, 21 percent of the test field soils are exposed or nearly exposed paleosols.
Balaguer Martínez, Josep Vicent; Del Castillo Aguas, Guadalupe; Gallego Iborra, Ana
2017-12-30
To assess whether there is a relationship between the prescription of antibiotics and the performance of complementary tests with frequency of use and loyalty in Primary Care. Analytical descriptive study performed through a network of Primary Care sentinel paediatricians (PAPenRed). Each paediatrician reviewed the spontaneous visits (in Primary Care and in Emergency Departments) of 15 patients for 12 months, randomly chosen from their quota. The prescription of antibiotics and the complementary tests performed on these patients were also collected. A total of 212 paediatricians took part and reviewed 2,726 patients. It was found that 8.3% were moderate over-users (mean + 1-2 standard deviations) and 5.2% extreme over-users (mean + 2 standard deviations). Almost half (49.6%) were high-loyalty patients (more than 75% of visits with their doctor). The incidence ratio of antibiotic prescriptions for moderate over-users was 2.13 (1.74-2.62) and 3.25 (2.55-4.13) for extreme over-users, compared to non-over-user children. The incidence ratio for the diagnostic tests were 2.25 (1.86-2.73) and 3.48 (2.78-4.35), respectively. The incidence ratios for antibiotic prescription were 1.34 (1.16-1.55) in patients with medium-high loyalty, 1.45 (1.15-1.83) for medium-low loyalty, and 1.08 (0.81-1.44) for those with low loyalty, compared to patients with high loyalty. The incidence ratios to perform diagnostic tests were 1.46 (1.27-1.67); 1.60 (1.28 - 2.00), and 0.84 (0.63-1.12), respectively. Antibiotics prescription and complementary tests were significantly related to medical overuse. They were also related to loyalty, but less significantly. Copyright © 2017. Publicado por Elsevier España, S.L.U.
A Portable Platform for Evaluation of Visual Performance in Glaucoma Patients
Rosen, Peter N.; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Marvasti, Amir H.; Medeiros, Felipe A.
2015-01-01
Purpose To propose a new tablet-enabled test for evaluation of visual performance in glaucoma, the PERformance CEntered Portable Test (PERCEPT), and to evaluate its ability to predict history of falls and motor vehicle crashes. Design Cross-sectional study. Methods The study involved 71 patients with glaucomatous visual field defects on standard automated perimetry (SAP) and 59 control subjects. The PERCEPT was based on the concept of increasing visual task difficulty to improve detection of central visual field losses in glaucoma patients. Subjects had to perform a foveal 8-alternative-forced-choice orientation discrimination task, while detecting a simultaneously presented peripheral stimulus within a limited presentation time. Subjects also underwent testing with the Useful Field of View (UFOV) divided attention test. The ability to predict history of motor vehicle crashes and falls was investigated by odds ratios and incident-rate ratios, respectively. Results When adjusted for age, only the PERCEPT processing speed parameter showed significantly larger values in glaucoma compared to controls (difference: 243ms; P<0.001). PERCEPT results had a stronger association with history of motor vehicle crashes and falls than UFOV. Each 1 standard deviation increase in PERCEPT processing speed was associated with an odds ratio of 2.69 (P = 0.003) for predicting history of motor vehicle crashes and with an incident-rate ratio of 1.95 (P = 0.003) for predicting history of falls. Conclusion A portable platform for testing visual function was able to detect functional deficits in glaucoma, and its results were significantly associated with history of involvement in motor vehicle crashes and history of falls. PMID:26445501
Revisiting tests for neglected nonlinearity using artificial neural networks.
Cho, Jin Seo; Ishida, Isao; White, Halbert
2011-05-01
Tests for regression neglected nonlinearity based on artificial neural networks (ANNs) have so far been studied by separately analyzing the two ways in which the null of regression linearity can hold. This implies that the asymptotic behavior of general ANN-based tests for neglected nonlinearity is still an open question. Here we analyze a convenient ANN-based quasi-likelihood ratio statistic for testing neglected nonlinearity, paying careful attention to both components of the null. We derive the asymptotic null distribution under each component separately and analyze their interaction. Somewhat remarkably, it turns out that the previously known asymptotic null distribution for the type 1 case still applies, but under somewhat stronger conditions than previously recognized. We present Monte Carlo experiments corroborating our theoretical results and showing that standard methods can yield misleading inference when our new, stronger regularity conditions are violated.
Strategies for leukemic biomarker detection using long-range surface plasmon-polaritons
NASA Astrophysics Data System (ADS)
Krupin, O.; Wang, C.; Berini, P.
2014-09-01
The suitability and use of long-range surface plasmon-polaritons for leukemic biomarker detection is discussed. A novel optical biosensor comprised of gold straight waveguides embedded in CYTOP with an etched microfluidic channel was tested for detecting leukemia in patient serum. Gold surface functionalization involved the interaction of protein G (PG) with antibodies by first adsorbing PG on bare gold and then antibodies (Immunoglobulin G, IgG). Differentiation between healthy and leukemia patients was based on the difference in ratios of Ig kappa (Igκ) and Ig lambda (Igλ) light chains in both serums. The ratio for a normal patient is ~1.4 - 2, whereas for a leukemia patient this ratio is altered. As a receptor (primary antibodies), goat anti-human anti-IgGκ and anti-IgGλ were used to functionalize the surface. Diluted normal and leukemia patient serums were tested over the aforementioned surfaces. The ratios of mass surface densities of IgGκ:IgGλ for normal serum (NS) and patient serum (PS) were found to be 1.55 and 1.92 respectively.
A preliminary characterization of parachute wake recontact
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strickland, J.H.; Macha, J.M.
1989-01-01
A series of tests was conducted on a 10-ft.-diameter ringslot parachute with a geometric porosity of 20% to establish the conditions under which ''wake recontact'' occurs. The vertical helicopter drop tests covered a range of mass ratios from 0.5 to 3.0 and a range of Froude numbers from 70 to 400. Data consisted of velocity time histories obtained using a laser tracker and diameter time histories obtained from photometric data. A collapse parameter based on the ratio of the maximum parachute diameter to the subsequent minimum diameter was correlated with the mass ratio M/sub R/ and the Froude number Frmore » or equivalently with the initial to final velocity ratio V/sub o//V/sub t/. For large values of V/sub o//V/sub t/ the collapse parameter R/sub c/ appears to be a function of M/sub R/ alone. Non-dimensional opening time and ''collapse time'' data were also correlated with M/sub R/ and V/sub o//V/sub t/. 11 refs., 10 figs., 1 tab.« less
Working memory training using EEG neurofeedback in normal young adults.
Xiong, Shi; Cheng, Chen; Wu, Xia; Guo, Xiaojuan; Yao, Li; Zhang, Jiacai
2014-01-01
Recent studies have shown that working memory (WM) performance can be improved by intensive and adaptive computerized training. Here, we explored the WM training effect using Electroencephalography (EEG) neurofeedback (NF) in normal young adults. In the first study, we identified the EEG features related to WM in normal young adults. The receiver operating characteristic (ROC) curve showed that the power ratio of the theta-to-alpha rhythms in the anterior-parietal region, accurately classified a high percentage of the EEG trials recorded during WM and fixation control (FC) tasks. Based on these results, a second study aimed to assess the training effects of the theta-to-alpha ratio and tested the hypothesis that up-regulating the power ratio can improve working memory behavior. Our results demonstrated that these normal young adults succeeded in improving their WM performance with EEG NF, and the pre- and post-test evaluations also indicated that WM performance increase in experimental group was significantly greater than control groups. In summary, our findings provided preliminarily evidence that WM performance can be improved through learned regulation of the EEG power ratio using EEG NF.
Cost effectiveness of population based BRCA1 founder mutation testing in Sephardi Jewish women.
Patel, Shreeya; Legood, Rosa; Evans, D Gareth; Turnbull, Clare; Antoniou, Antonis C; Menon, Usha; Jacobs, Ian; Manchanda, Ranjit
2018-04-01
Population-based BRCA1/BRCA2 founder-mutation testing has been demonstrated as cost effective compared with family history based testing in Ashkenazi Jewish women. However, only 1 of the 3 Ashkenazi Jewish BRCA1/BRCA2 founder mutations (185delAG[c.68_69delAG]), 5382insC[c.5266dupC]), and 6174delT[c.5946delT]) is found in the Sephardi Jewish population (185delAG[c.68_69delAG]), and the overall prevalence of BRCA mutations in the Sephardi Jewish population is accordingly lower (0.7% compared with 2.5% in the Ashkenazi Jewish population). Cost-effectiveness analyses of BRCA testing have not previously been performed at these lower BRCA prevalence levels seen in the Sephardi Jewish population. Here we present a cost-effectiveness analysis for UK and US populations comparing population testing with clinical criteria/family history-based testing in Sephardi Jewish women. A Markov model was built comparing the lifetime costs and effects of population-based BRCA1 testing, with testing using family history-based clinical criteria in Sephardi Jewish women aged ≥30 years. BRCA1 carriers identified were offered magnetic resonance imaging/mammograms and risk-reducing surgery. Costs are reported at 2015 prices. Outcomes include breast cancer, ovarian cancer, and excess deaths from heart disease. All costs and outcomes are discounted at 3.5%. The time horizon is lifetime, and perspective is payer. The incremental cost-effectiveness ratio per quality-adjusted life-year was calculated. Parameter uncertainty was evaluated through 1-way and probabilistic sensitivity analysis. Population testing resulted in gain in life expectancy of 12 months (quality-adjusted life-year = 1.00). The baseline discounted incremental cost-effectiveness ratio for UK population-based testing was £67.04/quality-adjusted life-year and for US population was $308.42/quality-adjusted life-year. Results were robust in the 1-way sensitivity analysis. The probabilistic sensitivity analysis showed 100% of simulations were cost effective at £20,000/quality-adjusted life-year UK and the $100,000/quality-adjusted life-year US willingness-to-pay thresholds. Scenario analysis showed that population testing remains cost effective in UK and US populations, even if premenopausal oophorectomy does not reduce breast cancer risk or if hormone replacement therapy compliance is nil. Population-based BRCA1 testing is highly cost effective compared with clinical criteria-driven approach in Sephardi Jewish women. This supports changing the paradigm to population-based BRCA testing in the Jewish population, regardless of Ashkenazi/Sephardi ancestry. Copyright © 2017 Elsevier Inc. All rights reserved.
Note: development of high speed confocal 3D profilometer.
Ang, Kar Tien; Fang, Zhong Ping; Tay, Arthur
2014-11-01
A high-speed confocal 3D profilometer based on the chromatic confocal technology and spinning Nipkow disk technique has been developed and tested. It can measure a whole surface topography by taking only one image that requires less than 0.3 s. Surface height information is retrieved based on the ratios of red, green, and blue color information. A new vector projection technique has developed to enhance the vertical resolution of the measurement. The measurement accuracy of the prototype system has been verified via different test samples.
NASA Astrophysics Data System (ADS)
Eissa, Maya S.; Abou Al Alamein, Amal M.
2018-03-01
Different innovative spectrophotometric methods were introduced for the first time for simultaneous quantification of sacubitril/valsartan in their binary mixture and in their combined dosage form without prior separation through two manipulation approaches. These approaches were developed and based either on two wavelength selection in zero-order absorption spectra namely; dual wavelength method (DWL) at 226 nm and 275 nm for valsartan, induced dual wavelength method (IDW) at 226 nm and 254 nm for sacubitril and advanced absorbance subtraction (AAS) based on their iso-absorptive point at 246 nm (λiso) and 261 nm (sacubitril shows equal absorbance values at the two selected wavelengths) or on ratio spectra using their normalized spectra namely; ratio difference spectrophotometric method (RD) at 225 nm and 264 nm for both of them in their ratio spectra, first derivative of ratio spectra (DR1) at 232 nm for valsartan and 239 nm for sacubitril and mean centering of ratio spectra (MCR) at 260 nm for both of them. Both sacubitril and valsartan showed linearity upon application of these methods in the range of 2.5-25.0 μg/mL. The developed spectrophotmetric methods were successfully applied to the analysis of their combined tablet dosage form ENTRESTO™. The adopted spectrophotometric methods were also validated according to ICH guidelines. The results obtained from the proposed methods were statistically compared to a reported HPLC method using Student t-test, F-test and a comparative study was also developed with one-way ANOVA, showing no statistical difference in accordance to precision and accuracy.
Use of motor abundance in old adults in the regulation of a narrow-based stance.
Hsu, Wei-Li; Lin, Kwan-Hwa; Yang, Rong-Sen; Cheng, Chih-Hsiu
2014-02-01
The ability to maintain stable balance while standing decreases with age. The body must coordinate multiple joints using "freeze" or "free" strategy, or a combination of both to ensure balance stability. The purpose of this study was to examine age-related changes in the use of motor abundance during upright stance on a narrow base without visual input. Uncontrolled manifold (UCM) analysis was used to decompose the movement variability of joints into goal-equivalent variability (GEV) and non-goal-equivalent variability (NGEV). The ratio between GEV and NGEV (UCM(ratio)) quantifies the joint coordination related to postural stability, and a high UCM(ratio) value indicates flexible control of joints. To perform balance tests, participants in this study (healthy young and old adults, 20 each) were asked to stand on a flat platform and on narrow wooden blocks with their eyes open and then eyes closed. In upright balance tests, both old and young adults maintained postural stability. GEV was greater than NGEV across all participants and conditions. However, GEV was higher in the young adults than in the old adults, whereas NGEV was higher in the old adults than in the young adults. Therefore, the old adults exhibited a lower UCM(ratio) than the young adults. The old adults were unable to exploit motor abundance and used a less flexible multi-joint coordination pattern to achieve stable balance. The UCM(ratio) value reflects the quality of postural control and can be used for assessing joint coordination in balance disorders.
Okazaki, Satoshi; Schirripa, Marta; Loupakis, Fotios; Cao, Shu; Zhang, Wu; Yang, Dongyun; Ning, Yan; Berger, Martin D; Miyamoto, Yuji; Suenaga, Mitsukuni; Iqubal, Syma; Barzi, Afsaneh; Cremolini, Chiara; Falcone, Alfredo; Battaglin, Francesca; Salvatore, Lisa; Borelli, Beatrice; Helentjaris, Timothy G; Lenz, Heinz-Josef
2017-11-15
The hypermethylated in cancer 1/sirtuin 1 (HIC1/SIRT1) axis plays an important role in regulating the nucleotide excision repair pathway, which is the main oxaliplatin-induced damage-repair system. On the basis of prior evidence that the variable number of tandem repeat (VNTR) sequence located near the promoter lesion of HIC1 is associated with HIC1 gene expression, the authors tested the hypothesis that this VNTR is associated with clinical outcome in patients with metastatic colorectal cancer who receive oxaliplatin-based chemotherapy. Four independent cohorts were tested. Patients who received oxaliplatin-based chemotherapy served as the training cohort (n = 218), and those who received treatment without oxaliplatin served as the control cohort (n = 215). Two cohorts of patients who received oxaliplatin-based chemotherapy were used for validation studies (n = 176 and n = 73). The VNTR sequence near HIC1 was analyzed by polymerase chain reaction analysis and gel electrophoresis and was tested for associations with the response rate, progression-free survival, and overall survival. In the training cohort, patients who harbored at least 5 tandem repeats (TRs) in both alleles had a significantly shorter PFS compared with those who had fewer than 4 TRs in at least 1 allele (9.5 vs 11.6 months; hazard ratio, 1.93; P = .012), and these findings remained statistically significant after multivariate analysis (hazard ratio, 2.00; 95% confidence interval, 1.13-3.54; P = .018). This preliminary association was confirmed in the validation cohort, and patients who had at least 5 TRs in both alleles had a worse PFS compared with the other cohort (7.9 vs 9.8 months; hazard ratio, 1.85; P = .044). The current findings suggest that the VNTR sequence near HIC1 could be a predictive marker for oxaliplatin-based chemotherapy in patients with metastatic colorectal cancer. Cancer 2017;123:4506-14. © 2017 American Cancer Society. © 2017 American Cancer Society.
Dark matter and MOND dynamical models of the massive spiral galaxy NGC 2841
NASA Astrophysics Data System (ADS)
Samurović, S.; Vudragović, A.; Jovanović, M.
2015-08-01
We study dynamical models of the massive spiral galaxy NGC 2841 using both the Newtonian models with Navarro-Frenk-White (NFW) and isothermal dark haloes, as well as various MOND (MOdified Newtonian Dynamics) models. We use the observations coming from several publicly available data bases: we use radio data, near-infrared photometry as well as spectroscopic observations. In our models, we find that both tested Newtonian dark matter approaches can successfully fit the observed rotational curve of NGC 2841. The three tested MOND models (standard, simple and, for the first time applied to another spiral galaxy than the Milky Way, Bekenstein's toy model) provide fits of the observed rotational curve with various degrees of success: the best result was obtained with the standard MOND model. For both approaches, Newtonian and MOND, the values of the mass-to-light ratios of the bulge are consistent with the predictions from the stellar population synthesis (SPS) based on the Salpeter initial mass function (IMF). Also, for Newtonian and simple and standard MOND models, the estimated stellar mass-to-light ratios of the disc agree with the predictions from the SPS models based on the Kroupa IMF, whereas the toy MOND model provides too low a value of the stellar mass-to-light ratio, incompatible with the predictions of the tested SPS models. In all our MOND models, we vary the distance to NGC 2841, and our best-fitting standard and toy models use the values higher than the Cepheid-based distance to the galaxy NGC 2841, and the best-fitting simple MOND model is based on the lower value of the distance. The best-fitting NFW model is inconsistent with the predictions of the Λ cold dark matter cosmology, because the inferred concentration index is too high for the established virial mass.
ERIC Educational Resources Information Center
Chan, David W.; Ho, Connie Suk-han; Tsang, Suk-man; Lee, Suk-han; Chung, Kevin K. H.
2007-01-01
Based on the data of the normative study of the "Hong Kong test of specific learning difficulties in reading and writing," and the "Test of visual-perceptual skills (non-motor)-Revised," 99 children aged between 6 and 10 1/2 years were identified as children with dyslexia out of the normative sample of 690 children. By…
NASA Technical Reports Server (NTRS)
Lippmann, S.; Finkenthal, M.; Huang, L. K.; Moos, H. W.; Stratton, B. C.; Yu, T. L.; Bhatia, A. K.
1987-01-01
Calcium was introduced into the TEXT tokamak, and its spectral emission was recorded in the 50-360 A range by an absolutely calibrated grazing incidence spectrometer. These observations of highly ionized species of calcium at known conditions of plasma electron temperature and density allow testing of line brightness ratio predictions based on theoretical values of temperature-dependent electron excitation rates. The confirmation of the expected ratios in Be I-like to O I-like calcium allows more confident use of these ratios as a density diagnostic of remote astrophysical sources such as solar flares.
Bakare, Muideen O; Ubochi, Vincent N; Okoroikpa, Ifeoma N; Aguocha, Chinyere M; Ebigbo, Peter O
2009-01-01
Background There may be need to assess intelligent quotient (IQ) scores in sub-Saharan African children with intellectual disability, either for the purpose of educational needs assessment or research. However, modern intelligence scales developed in the western parts of the world suffer limitation of widespread use because of the influence of socio-cultural variations across the world. This study examined the agreement between IQ scores estimation among Nigerian children with intellectual disability using clinicians' judgment based on International Classification of Diseases, tenth Edition (ICD - 10) criteria for mental retardation and caregivers judgment based on 'ratio IQ' scores calculated from estimated mental age in the context of socio-cultural milieu of the children. It proposed a viable option of IQ score assessment among sub-Saharan African children with intellectual disability, using a ratio of culture-specific estimated mental age and chronological age of the child in the absence of standardized alternatives, borne out of great diversity in socio-cultural context of sub-Saharan Africa. Methods Clinicians and care-givers independently assessed the children in relation to their socio-cultural background. Clinicians assessed the IQ scores of the children based on the ICD - 10 diagnostic criteria for mental retardation. 'Ratio IQ' scores were calculated from the ratio of estimated mental age and chronological age of each child. The IQ scores as assessed by the clinicians were then compared with the 'ratio IQ' scores using correlation statistics. Results A total of forty-four (44) children with intellectual disability were assessed. There was a significant correlation between clinicians' assessed IQ scores and the 'ratio IQ' scores employing zero order correlation without controlling for the chronological age of the children (r = 0.47, df = 42, p = 0.001). First order correlation controlling for the chronological age of the children showed higher correlation score between clinicians' assessed IQ scores and 'ratio IQ' scores (r = 0.75, df = 41, p = 0.000). Conclusion Agreement between clinicians' assessed IQ scores and 'ratio IQ' scores was good. 'Ratio IQ' test would provide a viable option of assessing IQ scores in sub-Saharan African children with intellectual disability in the absence of culture-appropriate standardized intelligence scales, which is often the case because of great diversity in socio-cultural structures of sub-Saharan Africa. PMID:19754953
Ejike, Chukwunonso E C C; Ezeanyika, Lawrence U S
2011-01-01
The usefulness of diet containing Telfairia occidentalis seeds, in managing benign prostatic hyperplasia (BPH) in rats was studied. Twenty male Wistar rats were divided into four equal groups. BPH was induced by sub-cutaneous injection of dihydrotestosterone (DHT) and estradiol valerate (ratio, 10:1) every other day for 28 days. Rats in the test group were placed on the test diet for 7 days following disease induction. One control group (DC) was fed on a normal diet for 7 days following disease induction. Two other control groups, HC and HDC, were given sub-cutaneous olive oil (vehicle) for the same duration, and placed on the test diet and normal diet, respectively. Markers of BPH, and hormone profile were determined using standard methods. The results show that relative prostate weight and protein content of the prostates were lower [albeit not significantly (p>0.05)] in the test group, relative to the DC group. Serum prostatic acid phosphatase concentrations (U/L) decreased significantly (p<0.05) from 2.9 ± 0.2 in the DC group to 2.1 ± 0.7 in the test group. Histological findings corroborate these data. The testosterone: estradiol ratio (× 10(3)) was increased from 4.0 ± 0.2 in the DC group to 4.6 ± 0.2 in the test group. The test diet reduced the mass and secretory activity of the enlarged prostate and may act by increasing the testosterone: estradiol ratio.
de Carvalho, Heraclito Barbosa; Andreuccetti, Gabriel; Rezende, Marcelo Rosa; Bernini, Celso; Silva, Jorge Santos; Leyton, Vilma; D'Andréa Greve, Julia Maria
2016-05-01
Earlier studies have already identified that a greater proportion of injured drivers are under the effects of illicit drugs than alcohol in Brazil, but the crash risk attributable to each substance is still unknown. Injured motorcycle drivers who were involved in traffic accidents in the West Zone of the city of Sao Paulo were recruited for a cross-sectional study based on crash culpability analysis. Alcohol and drug positivity among drivers was evaluated according to their responsibility for the crash. Culpability ratios were generated based on the proportion of drivers who were deemed culpable in relation to those considered not culpable according to the use of drugs and alcohol. Of the 273 drivers recruited, 10.6% tested positive for alcohol. Among those who were also tested for drugs (n=232), 20.3% had consumed either alcohol and/or other drugs, 15.5% of whom were positive only for drugs other than alcohol, specifically cannabis and cocaine. Drivers who tested positive for alcohol were significantly less likely to possess a valid driver's license and to report driving professionally, whereas those who had consumed only drugs were more likely to drive professionally. The culpability ratio estimated for alcohol-positive drivers was three times higher than that for alcohol-free drivers, showing a superior ratio than drivers who had consumed only drugs other than alcohol, who presented a 1.7 times higher culpability ratio than drug-free drivers. Substance use was overrepresented among culpable motorcycle drivers, with alcohol showing a greater contribution to crash culpability than other drugs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Andersen, Jesper H; Murray, Ciarán; Larsen, Martin M; Green, Norman; Høgåsen, Tore; Dahlgren, Elin; Garnaga-Budrė, Galina; Gustavson, Kim; Haarich, Michael; Kallenbach, Emilie M F; Mannio, Jaakko; Strand, Jakob; Korpinen, Samuli
2016-02-01
We report the development and application of a prototype tool for integrated assessment of chemical status in aquatic environments based on substance- and matrix-specific environmental assessment criteria (thresholds). The Chemical Status Assessment Tool (CHASE) integrates data on hazardous substances in water, sediments and biota as well as bio-effect indicators and is based on a substance- or bio-effect-specific calculation of a 'contamination ratio' being the ratio between an observed concentration and a threshold value. Values <1.0 indicate areas potentially 'unaffected', while values >1.0 indicate areas potentially 'affected'. These ratios are combined within matrices, i.e. for water, sediment and biota and for biological effects. The overall assessment used a 'one out, all out principle' with regard to each matrix. The CHASE tool was tested in the Baltic Sea and the North Sea in 376 assessment units. In the former, the chemical status was >1.0 in practically all areas indicating that all areas assessed were potentially affected. The North Sea included areas classified as unaffected or affected. The CHASE tool can in combination with temporal trend assessments of individual substances be advantageous for use in remedial action plans and, in particular, for the science-based evaluation of the status and for determining which specific substances are responsible for a status as potentially affected.
Likelihood Ratio Tests for Special Rasch Models
ERIC Educational Resources Information Center
Hessen, David J.
2010-01-01
In this article, a general class of special Rasch models for dichotomous item scores is considered. Although Andersen's likelihood ratio test can be used to test whether a Rasch model fits to the data, the test does not differentiate between special Rasch models. Therefore, in this article, new likelihood ratio tests are proposed for testing…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oktay, S.D.; Santschi, P.H.; Moran, J.E.
2000-03-01
Anthropogenic sources from nuclear reprocessing discharges and bomb test fallout have completely overwhelmed the natural signal on the surface of the earth in the last 50 years. However, the transfer functions in and out of environmental compartments are not well known due to temporal variations in the sources of {sup 129}I and to a lack of knowledge regarding the forms of iodine. From a vertical profile of {sup 129}I/{sup 127}I ratios in sediments located in the Mississippi Delta region in approximately 60 meters water depth, the {sup 129}I input function to this region was reconstructed. Dates in the core weremore » assigned based on the plutonium peak at 20 cm depth (assumed to have been deposited in 1963) and the excess {sup 210}Pb profile in the same depth interval, and below that, based on the steadily decreasing {sup 240}Pu/{sup 239}Pu ratios from a ratio of 0.18 at 22 cm to 0.05 at 57 cm depth, the 1953 horizon. Atom ratios of {sup 129}I/{sup 137}I Cs, decay corrected to 1962, the year of maximum radionuclide production, are about 0.3, very close to the production ratios of about 0.2 during atomic bomb tests. This evidence, combined with other observations, strongly suggests that {sup 129}I in Mississippi River Delta sediments originates from atomic bomb fallout eroded from soils of the Mississippi River drainage basin, with little alteration of the isotopic ratios during transport from watershed to coastal deposits. Based on these observations and on laboratory evidence, the authors propose a conceptual model which explains this correspondence and the low {sup 129}I/{sup 127}I ratios. Differences in mobilities of the different chemical forms of {sup 129}I and {sup 127}I, as well as the variances in chemical forms of {sup 129}I from nuclear bomb fallout versus nuclear fuel reprocessing, are proposed to have created such a correspondence between I-isotope ratios and bomb fallout nuclides, without revealing recent inputs from nuclear fuel reprocessing releases to the northern hemisphere observed in watersheds of the USA and Europe.« less
NASA Technical Reports Server (NTRS)
Chu, Julio; Lawing, Pierce L.
1990-01-01
A high Reynolds number test of a 5 percent thick low aspect ratio semispan wing was conducted in the adaptive wall test section of the Langley 0.3 m Transonic Cryogenic Tunnel. The model tested had a planform and a NACA 64A-105 airfoil section that is similar to that of the pressure instrumented canard on the X-29 experimental aircraft. Chordwise pressure data for Mach numbers of 0.3, 0.7, and 0.9 were measured for an angle-of-attack range of -4 to 15 deg. The associated Reynolds numbers, based on the geometric mean chord, encompass most of the flight regime of the canard. This test was a free transition investigation. A summary of the wing pressures are presented without analysis as well as adapted test section top and bottom wall pressure signatures. However, the presented graphical data indicate Reynolds number dependent complex leading edge separation phenomena. This data set supplements the existing high Reynolds number database and are useful for computational codes comparison.
NASA Technical Reports Server (NTRS)
Gutierrez-Lemini, Danton; McCool, Alex (Technical Monitor)
2001-01-01
A method is developed to establish the J-resistance function for an isotropic linear viscoelastic solid of constant Poisson's ratio using the single-specimen technique with constant-rate test data. The method is based on the fact that, for a test specimen of fixed crack size under constant rate, the initiation J-integral may be established from the crack size itself, the actual external load and load-point displacement at growth initiation, and the relaxation modulus of the viscoelastic solid, without knowledge of the complete test record. Since crack size alone, of the required data, would be unknown at each point of the load-vs-load-point displacement curve of a single-specimen test, an expression is derived to estimate it. With it, the physical J-integral at each point of the test record may be established. Because of its basis on single-specimen testing, not only does the method not require the use of multiple specimens with differing initial crack sizes, but avoids the need for tracking crack growth as well.
An accurate test for homogeneity of odds ratios based on Cochran's Q-statistic.
Kulinskaya, Elena; Dollinger, Michael B
2015-06-10
A frequently used statistic for testing homogeneity in a meta-analysis of K independent studies is Cochran's Q. For a standard test of homogeneity the Q statistic is referred to a chi-square distribution with K-1 degrees of freedom. For the situation in which the effects of the studies are logarithms of odds ratios, the chi-square distribution is much too conservative for moderate size studies, although it may be asymptotically correct as the individual studies become large. Using a mixture of theoretical results and simulations, we provide formulas to estimate the shape and scale parameters of a gamma distribution to fit the distribution of Q. Simulation studies show that the gamma distribution is a good approximation to the distribution for Q. Use of the gamma distribution instead of the chi-square distribution for Q should eliminate inaccurate inferences in assessing homogeneity in a meta-analysis. (A computer program for implementing this test is provided.) This hypothesis test is competitive with the Breslow-Day test both in accuracy of level and in power.
Testing an earthquake prediction algorithm
Kossobokov, V.G.; Healy, J.H.; Dewey, J.W.
1997-01-01
A test to evaluate earthquake prediction algorithms is being applied to a Russian algorithm known as M8. The M8 algorithm makes intermediate term predictions for earthquakes to occur in a large circle, based on integral counts of transient seismicity in the circle. In a retroactive prediction for the period January 1, 1985 to July 1, 1991 the algorithm as configured for the forward test would have predicted eight of ten strong earthquakes in the test area. A null hypothesis, based on random assignment of predictions, predicts eight earthquakes in 2.87% of the trials. The forward test began July 1, 1991 and will run through December 31, 1997. As of July 1, 1995, the algorithm had forward predicted five out of nine earthquakes in the test area, which success ratio would have been achieved in 53% of random trials with the null hypothesis.
The effects of ground hydrology on climate sensitivity to solar constant variations
NASA Technical Reports Server (NTRS)
Chou, S. H.; Curran, R. J.; Ohring, G.
1979-01-01
The effects of two different evaporation parameterizations on the climate sensitivity to solar constant variations are investigated by using a zonally averaged climate model. The model is based on a two-level quasi-geostrophic zonally averaged annual mean model. One of the evaporation parameterizations tested is a nonlinear formulation with the Bowen ratio determined by the predicted vertical temperature and humidity gradients near the earth's surface. The other is the linear formulation with the Bowen ratio essentially determined by the prescribed linear coefficient.
Ding, Wen Hui; Li, Xiu Zhen; Jiang, Jun Yan; Huang, Xing; Zhang, Yun Qing; Zhang, Qian; Zhou, Yun Xuan
2016-05-01
The salt marsh plant communities were investigated with quadrats in the southern Chongming Dongtan. Based on the vegetation coverage and the 2×2 contingency table, 8 common species among the 17 higher plants recorded were analyzed. The variance ratio of overall association, Chi-square test and Spearman rank correlation coefficient were used to describe the relevance and correlations between species pairs. The results showed that W (48.61), a statistical index to test the variance ratio (VR=0.61), fell outside of the range of Chi-square test, indicating that the overall correlation of all vegetation species was significantly negative. According to the environment adaptation mode of dominant species and the main influencing factors, the species were divided into 4 ecological groups, i.e., Phragmites australis, Carex scabrifolia-Scirpus triqueter - Juncellus serotinus, Spartina alterniflora - Scirpus mariqueter, Echinochloa crusgalli - Imperata cylindrica, based on the ranking of Spearman correlation coefficient. The inter-specific relationships in the salt marsh plant community of southern Chongming Dongtan were complicated and extremely unstable with species sensitive to environmental impacts. According to the analysis of relationships between the species and their pre-sent distribution, we suggested using S. mariqueter as target species to provide strategies for protecting native species based habitats.
Sinharay, Sandip; Jensen, Jens Ledet
2018-06-27
In educational and psychological measurement, researchers and/or practitioners are often interested in examining whether the ability of an examinee is the same over two sets of items. Such problems can arise in measurement of change, detection of cheating on unproctored tests, erasure analysis, detection of item preknowledge, etc. Traditional frequentist approaches that are used in such problems include the Wald test, the likelihood ratio test, and the score test (e.g., Fischer, Appl Psychol Meas 27:3-26, 2003; Finkelman, Weiss, & Kim-Kang, Appl Psychol Meas 34:238-254, 2010; Glas & Dagohoy, Psychometrika 72:159-180, 2007; Guo & Drasgow, Int J Sel Assess 18:351-364, 2010; Klauer & Rettig, Br J Math Stat Psychol 43:193-206, 1990; Sinharay, J Educ Behav Stat 42:46-68, 2017). This paper shows that approaches based on higher-order asymptotics (e.g., Barndorff-Nielsen & Cox, Inference and asymptotics. Springer, London, 1994; Ghosh, Higher order asymptotics. Institute of Mathematical Statistics, Hayward, 1994) can also be used to test for the equality of the examinee ability over two sets of items. The modified signed likelihood ratio test (e.g., Barndorff-Nielsen, Biometrika 73:307-322, 1986) and the Lugannani-Rice approximation (Lugannani & Rice, Adv Appl Prob 12:475-490, 1980), both of which are based on higher-order asymptotics, are shown to provide some improvement over the traditional frequentist approaches in three simulations. Two real data examples are also provided.
Detection, discrimination, and real-time tracking of cracks in rotating disks
NASA Astrophysics Data System (ADS)
Haase, Wayne C.; Drumm, Michael J.
2002-06-01
The purpose of this effort was to develop a system* to detect, discriminate and track fatigue cracks in rotating disks. Aimed primarily at jet engines in flight applications, the system also has value for detecting cracks in a spin pit during low cycle fatigue testing, and for monitoring the health of steam turbines and land-based gas turbine engines for maintenance purposes. The results of this effort produced: a physics-based model that describes the change in the center of mass of a rotating disk using damping ratio, initial unbalance and crack size as parameters; the development of a data acquisition and analysis system that can detect and discriminate a crack using a single cycle of data; and initial validation of the model through testing in a spin pit. The development of the physics-based model also pointed to the most likely regimes for crack detection; identified specific powers of (omega) search for in specific regimes; dictated a particular type of data acquisition for crack discrimination; and demonstrated a need for a higher signal-to-noise ratio in the measurement of the basic vibration signal.
Lasserre, Camille; De Saint Martin, Luc; Cuzon, Gaelle; Bogaerts, Pierre; Lamar, Estelle; Glupczynski, Youri; Naas, Thierry; Tandé, Didier
2015-07-01
The recognition of carbapenemase-producing Enterobacteriaceae (CPE) isolates is a major laboratory challenge, and their inappropriate or delayed detection may have negative impacts on patient management and on the implementation of infection control measures. We describe here a matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based method to detect carbapenemase activity in Enterobacteriaceae. After a 20-min incubation of the isolate with 0.5 mg/ml imipenem at 37°C, supernatants were analyzed by MALDI-TOF in order to identify peaks corresponding to imipenem (300 Da) and an imipenem metabolite (254 Da). A total of 223 strains, 77 CPE (OXA-48 variants, KPC, NDM, VIM, IMI, IMP, and NMC-A) and 146 non-CPE (cephalosporinases, extended-spectrum β-lactamases [ESBLs], and porin defects), were tested and used to calculate a ratio of imipenem hydrolysis: mass spectrometry [MS] ratio = metabolite/(imipenem + metabolite). An MS ratio cutoff was statistically determined to classify strains as carbapenemase producers (MS ratio of ≥0.82). We validated this method first by testing 30 of our 223 isolates (15 CPE and 15 non-CPE) 10 times to calculate an intraclass correlation coefficient (ICC of 0.98), showing the excellent repeatability of the method. Second, 43 strains (25 CPE and 18 non-CPE) different from the 223 strains used to calculate the ratio cutoff were used as external controls and blind tested. They yielded sensitivity and specificity of 100%. The total cost per test is <0.10 U.S. dollars (USD). This easy-to-perform assay is time-saving, cost-efficient, and highly reliable and might be used in any routine laboratory, given the availability of mass spectrometry, to detect CPE. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Biomedical and sensing applications of a multi-mode biodegradable phosphate-based optical fiber
NASA Astrophysics Data System (ADS)
Podrazky, Ondřej; Peterka, Pavel; Vytykáčová, SoÅa.; Proboštová, Jana; Kuneš, Martin; Lyutakov, Oleksiy; Ceci-Ginistrelli, Edoardo; Pugliese, Diego; Boetti, Nadia G.; Janner, Davide; Milanese, Daniel
2018-02-01
We report on the employment of a biodegradable phosphate-based optical fiber as a pH sensing probe in physiological environment. The phosphate-based optical fiber preform was fabricated by the rod-in-tube technique. The fiber biodegradability was first tested in-vitro and then its biodegradability and toxicity were tested in-vivo. Optical probes for pH sensing were prepared by the immobilization of a fluorescent dye on the fiber tip by a sol-gel method. The fluorescence response of the pH-sensor was measured as a ratio of the emission intensities at the excitation wavelengths of 405 and 450 nm.
340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays.
Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian
2016-09-19
We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems.
Signature of Microbial Dysbiosis in Periodontitis.
Meuric, Vincent; Le Gall-David, Sandrine; Boyer, Emile; Acuña-Amador, Luis; Martin, Bénédicte; Fong, Shao Bing; Barloy-Hubler, Frederique; Bonnaure-Mallet, Martine
2017-07-15
Periodontitis is driven by disproportionate host inflammatory immune responses induced by an imbalance in the composition of oral bacteria; this instigates microbial dysbiosis, along with failed resolution of the chronic destructive inflammation. The objectives of this study were to identify microbial signatures for health and chronic periodontitis at the genus level and to propose a model of dysbiosis, including the calculation of bacterial ratios. Published sequencing data obtained from several different studies (196 subgingival samples from patients with chronic periodontitis and 422 subgingival samples from healthy subjects) were pooled and subjected to a new microbiota analysis using the same Visualization and Analysis of Microbial Population Structures (VAMPS) pipeline, to identify microbiota specific to health and disease. Microbiota were visualized using CoNet and Cytoscape. Dysbiosis ratios, defined as the percentage of genera associated with disease relative to the percentage of genera associated with health, were calculated to distinguish disease from health. Correlations between the proposed dysbiosis ratio and the periodontal pocket depth were tested with a different set of data obtained from a recent study, to confirm the relevance of the ratio as a potential indicator of dysbiosis. Beta diversity showed significant clustering of periodontitis-associated microbiota, at the genus level, according to the clinical status and independent of the methods used. Specific genera ( Veillonella , Neisseria , Rothia , Corynebacterium , and Actinomyces ) were highly prevalent (>95%) in health, while other genera ( Eubacterium , Campylobacter , Treponema , and Tannerella ) were associated with chronic periodontitis. The calculation of dysbiosis ratios based on the relative abundance of the genera found in health versus periodontitis was tested. Nonperiodontitis samples were significantly identifiable by low ratios, compared to chronic periodontitis samples. When applied to a subgingival sample set with well-defined clinical data, the method showed a strong correlation between the dysbiosis ratio, as well as a simplified ratio ( Porphyromonas , Treponema , and Tannerella to Rothia and Corynebacterium ), and pocket depth. Microbial analysis of chronic periodontitis can be correlated with the pocket depth through specific signatures for microbial dysbiosis. IMPORTANCE Defining microbiota typical of oral health or chronic periodontitis is difficult. The evaluation of periodontal disease is currently based on probing of the periodontal pocket. However, the status of pockets "on the mend" or sulci at risk of periodontitis cannot be addressed solely through pocket depth measurements or current microbiological tests available for practitioners. Thus, a more specific microbiological measure of dysbiosis could help in future diagnoses of periodontitis. In this work, data from different studies were pooled, to improve the accuracy of the results. However, analysis of multiple species from different studies intensified the bacterial network and complicated the search for reproducible microbial signatures. Despite the use of different methods in each study, investigation of the microbiota at the genus level showed that some genera were prevalent (up to 95% of the samples) in health or disease, allowing the calculation of bacterial ratios (i.e., dysbiosis ratios). The correlation between the proposed ratios and the periodontal pocket depth was tested, which confirmed the link between dysbiosis ratios and the severity of the disease. The results of this work are promising, but longitudinal studies will be required to improve the ratios and to define the microbial signatures of the disease, which will allow monitoring of periodontal pocket recovery and, conceivably, determination of the potential risk of periodontitis among healthy patients. Copyright © 2017 American Society for Microbiology.
Flow Cytometric Human Leukocyte Antigen-B27 Typing with Stored Samples for Batch Testing
Seo, Bo Young
2013-01-01
Background Flow cytometry (FC) HLA-B27 typing is still used extensively for the diagnosis of spondyloarthropathies. If patient blood samples are stored for a prolonged duration, this testing can be performed in a batch manner, and in-house cellular controls could easily be procured. In this study, we investigated various methods of storing patient blood samples. Methods We compared four storage methods: three methods of analyzing lymphocytes (whole blood stored at room temperature, frozen mononuclear cells, and frozen white blood cells [WBCs] after lysing red blood cells [RBCs]), and one method using frozen platelets (FPLT). We used three ratios associated with mean fluorescence intensities (MFI) for HLAB27 assignment: the B27 MFI ratio (sample/control) for HLA-B27 fluorescein-5-isothiocyanate (FITC); the B7 MFI ratio for HLA-B7 phycoerythrin (PE); and the ratio of these two ratios, B7/B27 ratio. Results Comparing the B27 MFI ratios of each storage method for the HLA-B27+ samples and the B7/B27 ratios for the HLA-B7+ samples revealed that FPLT was the best of the four methods. FPLT had a sensitivity of 100% and a specificity of 99.3% for HLA-B27 assignment in DNA-typed samples (N=164) when the two criteria, namely, B27 MFI ratio >4.0 and B7/B27 ratio <1.5, were used. Conclusions The FPLT method was found to offer a simple, economical, and accurate method of FC HLA-B27 typing by using stored patient samples. If stored samples are used, this method has the potential to replace the standard FC typing method when used in combination with a complementary DNA-based method. PMID:23667843
Oscillating-flow loss test results in rectangular heat exchanger passages
NASA Technical Reports Server (NTRS)
Wood, J. Gary
1991-01-01
Test results of oscillating flow losses in rectangular heat exchanger passages of various aspect ratios are given. This work was performed in support of the design of a free-piston Stirling engine (FPSE) for a dynamic space power conversion system. Oscillating flow loss testing was performed using an oscillating flow rig, which was based on a variable stroke and variable frequency linear drive motor. Tests were run over a range of oscillating flow parameters encompassing the flow regimes of the proposed engine design. Test results are presented in both tabular and graphical form and are compared against analytical predictions.
Güzelbulut, Fatih; Çetınkaya, Züleyha Akkan; Sezıklı, Mesut; Yaşar, Bülent; Ozkara, Selvinaz; Övünç, Ayşe Oya Kurdaş
2011-06-01
The aim of this study was to evaluate the diagnostic accuracy of aspartate aminotransferase-platelet ratio index, the Forns index and FIB-4 for the assessment of hepatic fibrosis in chronic hepatitis C patients by comparison with liver biopsy. We retrospectively reviewed our computerized data of chronic hepatitis C patients who admitted to the Gastroenterology Clinic between 2004 and 2008. Treatment-naive chronic hepatitis C patients who had undergone liver biopsy and had laboratory test results allowing the calculation of aspartate aminotransferase-platelet ratio index, the Forns index and FIB-4 were included in this study. The degree of fibrosis was scored according to the METAVIR staging system. Significant fibrosis was defined as F2-4 and cirrhosis as F4. Aspartate aminotransferase-platelet ratio index, the Forns index and FIB-4 were calculated based on the original studies. Tests results were compared between groups F0-1 (no or mild fibrosis) versus F2-4 (significant fibrosis) and F03 (no cirrhosis) versus F4 (cirrhosis). One hundred and fifty patients with chronic hepatitis C were included in this study. The areas under the ROC curves of the Forns index, aspartate aminotransferase-platelet ratio index and FIB-4 to predict significant fibrosis were 0.795, 0.774 and 0.764, respectively. The area under the ROC curves of the Forns index, aspartate aminotransferase-platelet ratio index and FIB-4 to predict cirrhosis were 0.879, 0.839 and 0.874, respectively. The Forns index, aspartate aminotransferase-platelet ratio index and FIB-4 were accurate noninvasive blood tests to predict the presence or absence of significant fibrosis and cirrhosis in half of the chronic hepatitis C patients. The Forns index was slightly better than the aspartate aminotransferase-platelet ratio index and FIB-4 in the prediction of significant fibrosis and cirrhosis.
Cost-Aware Design of a Discrimination Strategy for Unexploded Ordnance Cleanup
2011-02-25
Acronyms ANN: Artificial Neural Network AUC: Area Under the Curve BRAC: Base Realignment And Closure DLRT: Distance Likelihood Ratio Test EER...Discriminative Aggregate Nonparametric [25] Artificial Neural Network ANN Discriminative Aggregate Parametric [33] 11 Results and Discussion Task #1
Myer, Gregory D.; Ford, Kevin R.; Khoury, Jane; Succop, Paul; Hewett, Timothy E.
2012-01-01
Background Prospective measures of high knee abduction moment (KAM) during landing identify female athletes at high risk for anterior cruciate ligament injury. Laboratory-based measurements demonstrate 90% accuracy in prediction of high KAM. Clinic-based prediction algorithms that employ correlates derived from laboratory-based measurements also demonstrate high accuracy for prediction of high KAM mechanics during landing. Hypotheses Clinic-based measures derived from highly predictive laboratory-based models are valid for the accurate prediction of high KAM status, and simultaneous measurements using laboratory-based and clinic-based techniques highly correlate. Study Design Cohort study (diagnosis); Level of evidence, 2. Methods One hundred female athletes (basketball, soccer, volleyball players) were tested using laboratory-based measures to confirm the validity of identified laboratory-based correlate variables to clinic-based measures included in a prediction algorithm to determine high KAM status. To analyze selected clinic-based surrogate predictors, another cohort of 20 female athletes was simultaneously tested with both clinic-based and laboratory-based measures. Results The prediction model (odds ratio: 95% confidence interval), derived from laboratory-based surrogates including (1) knee valgus motion (1.59: 1.17-2.16 cm), (2) knee flexion range of motion (0.94: 0.89°-1.00°), (3) body mass (0.98: 0.94-1.03 kg), (4) tibia length (1.55: 1.20-2.07 cm), and (5) quadriceps-to-hamstrings ratio (1.70: 0.48%-6.0%), predicted high KAM status with 84% sensitivity and 67% specificity (P < .001). Clinic-based techniques that used a calibrated physician’s scale, a standard measuring tape, standard camcorder, ImageJ software, and an isokinetic dynamometer showed high correlation (knee valgus motion, r = .87; knee flexion range of motion, r = .95; and tibia length, r = .98) to simultaneous laboratory-based measurements. Body mass and quadriceps-to-hamstrings ratio were included in both methodologies and therefore had r values of 1.0. Conclusion Clinically obtainable measures of increased knee valgus, knee flexion range of motion, body mass, tibia length, and quadriceps-to-hamstrings ratio predict high KAM status in female athletes with high sensitivity and specificity. Female athletes who demonstrate high KAM landing mechanics are at increased risk for anterior cruciate ligament injury and are more likely to benefit from neuromuscular training targeted to this risk factor. Use of the developed clinic-based assessment tool may facilitate high-risk athletes’ entry into appropriate interventions that will have greater potential to reduce their injury risk. PMID:20595554
Acceptance Testing of Thermoluminescent Dosimeter Holders.
Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A
2018-05-01
The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.
Aerodynamic and heat transfer analysis of the low aspect ratio turbine using a 3D Navier-Stokes code
NASA Astrophysics Data System (ADS)
Choi, D.; Knight, C. J.
1991-06-01
The single-stage, high-pressure ratio Garrett Low Aspect Ratio Turbine (LART) test data obtained in a shock tunnel are employed as a basis for evaluating a new three-dimensional Navier Stokes code based on the O-H grid system. It uses Coakley's two-equation turbulence modeling with viscous sublayer resolution. For the nozzle guide vanes, calculations were made based on two grid zones: an O-grid zone wrapping around airfoil and an H-grid zone outside of the O-grid zone, including the regions upstream of the leadig edge and downstream of the trailing edge. For the rotor blade row, a third O-grid zone was added for the tip-gap region leakage flow. The computational results compare well with experiment. These comparisons include heat transfer distributions on the airfoils and end-walls. The leakage flow through the tip-gap clearance is well resolved.
Design and evaluation of a Dean vortex-based micromixer.
Howell, Peter B; Mott, David R; Golden, Joel P; Ligler, Frances S
2004-12-01
A mixer, based on the Dean vortex, is fabricated and tested in an on-chip format. When fluid is directed around a curve under pressure driven flow, the high velocity streams in the center of the channel experience a greater centripetal force and so are deflected outward. This creates a pair of counter-rotating vortices moving fluid toward the inner wall at the top and bottom of the channel and toward the outer wall in the center. For the geometries studied, the vortices were first seen at Reynolds numbers between 1 and 10 and became stronger as the flow velocity is increased. Vortex formation was monitored in channels with depth/width ratios of 0.5, 1.0, and 2.0. The lowest aspect ratio strongly suppressed vortex formation. Increasing the aspect ratio above 1 appeared to provide improved mixing. This design has the advantages of easy fabrication and low surface area.
Digital micromirror device based ophthalmoscope with concentric circle scanning.
Damodaran, Mathi; Vienola, Kari V; Braaf, Boy; Vermeer, Koenraad A; de Boer, Johannes F
2017-05-01
Retinal imaging is demonstrated using a novel scanning light ophthalmoscope based on a digital micromirror device with 810 nm illumination. Concentric circles were used as scan patterns, which facilitated fixation by a human subject for imaging. An annular illumination was implemented in the system to reduce the background caused by corneal reflections and thereby to enhance the signal-to-noise ratio. A 1.9-fold increase in the signal-to-noise ratio was found by using an annular illumination aperture compared to a circular illumination aperture, resulting in a 5-fold increase in imaging speed and a better signal-to-noise ratio compared to our previous system. We tested the imaging performance of our system by performing non-mydriatic imaging on two subjects at a speed of 7 Hz with a maximum 20° (diameter) field of view. The images were shot noise limited and clearly show various anatomical features of the retina with high contrast.
Digital micromirror device based ophthalmoscope with concentric circle scanning
Damodaran, Mathi; Vienola, Kari V.; Braaf, Boy; Vermeer, Koenraad A.; de Boer, Johannes F.
2017-01-01
Retinal imaging is demonstrated using a novel scanning light ophthalmoscope based on a digital micromirror device with 810 nm illumination. Concentric circles were used as scan patterns, which facilitated fixation by a human subject for imaging. An annular illumination was implemented in the system to reduce the background caused by corneal reflections and thereby to enhance the signal-to-noise ratio. A 1.9-fold increase in the signal-to-noise ratio was found by using an annular illumination aperture compared to a circular illumination aperture, resulting in a 5-fold increase in imaging speed and a better signal-to-noise ratio compared to our previous system. We tested the imaging performance of our system by performing non-mydriatic imaging on two subjects at a speed of 7 Hz with a maximum 20° (diameter) field of view. The images were shot noise limited and clearly show various anatomical features of the retina with high contrast. PMID:28663905
Davido, B; Badr, C; Lagrange, A; Makhloufi, S; De Truchis, P; Perronne, C; Salomon, J; Dinh, A
2016-06-01
29-69 % of pneumonias are microbiologically documented because it can be considered as an invasive procedure with variable test sensitivity. However, it drastically impacts therapeutic strategy in particular the use of antibiotics. Serum protein electrophoresis (SPEP) is a routine and non-invasive test commonly used to identify serum protein disorders. As virus and bacteria may induce different globulins production, we hypothesize that SPEP can be used as an etiological diagnosis test. Retrospective study conducted from 1/1/13 until 5/1/15 among patient hospitalized for an acute community-acquired pneumonia based on fever, crackles and radiological abnormalities. α/β, α/γ, β/γ globulins and albumin/globulin (A/G) ratio were calculated from SPEP. Data were analyzed in 3 groups: documented viral (DVP) or bacterial pneumonia (DBP) and supposedly bacterial pneumonia (SBP). We used ANOVA statistic test with multiple comparisons using CI95 and ROC curve to compare them. 109 patients included divided into DBP (n = 16), DVP (n = 26) and SBP (n = 67). Mean age was 62 ± 18 year-old with a sex ratio M/F of 1.3. Underlying conditions (e.g. COPD, diabetes) were comparable between groups in multivariate analysis. Means of A/G ratio were 0.80 [0.76-0.84], 0.96 [0.91-1.01], 1.08 [0.99-1.16] respectively for DBP, SBP and DVP (p = 0.0002). A/G ratio cut-off value of 0.845 has a sensitivity of 87.5 % and a specificity of 73.1 %. A/G ratio seems to be an easy diagnostic tool to differentiate bacterial from viral pneumonia. A/G ratio cut-off value below 0.845 seems to be predictable of a bacterial origin and support the use of antibiotics.
NOx Emissions Performance and Correlation Equations for a Multipoint LDI Injector
NASA Technical Reports Server (NTRS)
He, Zhuohui J.; Chang, Clarence T.; Follen, Caitlin E.
2014-01-01
Lean Direct Injection (LDI) is a combustor concept that reduces nitrogen oxides (NOx) emissions. This paper looks at a 3-zone multipoint LDI concept developed by Parker Hannifin Corporation. The concept was tested in a flame-tube test facility at NASA Glenn Research Center. Due to test facility limitations, such as inlet air temperature and pressure, the flame-tube test was not able to cover the full set of engine operation conditions. Three NOx correlation equations were developed based on assessing NOx emissions dependencies on inlet air pressure (P3), inlet air temperature (T3), and fuel air equivalence ratio (phi) to estimate the NOx emissions at the unreachable high engine power conditions. As the results, the NOx emissions are found to be a strong function of combustion inlet air temperature and fuel air equivalence ratio but a weaker function of inlet air pressure. With these three equations, the NOx emissions performance of this injector concept is calculated as a 66 percent reduction relative to the ICAO CAEP-6 standard using a 55:1 pressure-ratio engine cycle. Uncertainty in the NOx emissions estimation increases as the extrapolation range departs from the experimental conditions. Since maximum inlet air pressure tested was less than 50 percent of the full power engine inlet air pressure, a future experiment at higher inlet air pressure conditions is needed to confirm the NOx emissions dependency on inlet air pressure.
NOx Emissions Performance and Correlation Equations for a Multipoint LDI Injector
NASA Technical Reports Server (NTRS)
He, Zhuohui Joe; Chang, Clarence T.; Follen, Caitlin E.
2015-01-01
Lean Direct Injection (LDI) is a combustor concept that reduces nitrogen oxides (NOx) emissions.This paper looks at a 3-zone multipoint LDI concept developed by Parker Hannifin Corporation. The concept was tested in a flame-tube test facility at NASA Glenn Research Center. Due to test facility limitations, such as inlet air temperature and pressure, the flame-tube test was not able to cover the full set of engine operation conditions. Three NOx correlation equations were developed based on assessing NOx emissions dependencies on inlet air pressure (P3), inlet air temperature (T3), and fuel air equivalence ratio(theta) to estimate the NOx emissions at the unreachable high engine power conditions. As the results, the NOx emissions are found to be a strong function of combustion inlet air temperature and fuel air equivalence ratio but a weaker function of inlet air pressure. With these three equations, the NOx emissions performance of this injector concept is calculated as a 66 reduction relative to the ICAO CAEP-6 standard using a 55:1 pressure-ratio engine cycle. Uncertainty in the NOx emissions estimation increases as the extrapolation range departs from the experimental conditions. Since maximum inlet air pressure tested was less than 50 of the full power engine inlet air pressure, a future experiment at higher inlet air pressure conditions is needed to confirm the NOx emissions dependency on inlet air pressure.
NOx Emissions Performance and Correlation Equations for a Multipoint LDI Injector
NASA Technical Reports Server (NTRS)
He, Zhuohui J.; Chang, Clarence T.; Follen, Caitlin E.
2015-01-01
Lean Direct Injection (LDI) is a combustor concept that reduces nitrogen oxides (NOx) emissions. This paper looks at a 3-zone multipoint LDI concept developed by Parker Hannifin Corporation. The concept was tested in a flame-tube test facility at NASA Glenn Research Center. Due to test facility limitations, such as inlet air temperature and pressure, the flame-tube test was not able to cover the full set of engine operation conditions. Three NOx correlation equations were developed based on assessing NOx emissions dependencies on inlet air pressure (P3), inlet air temperature (T3), and fuel air equivalence ratio (?) to estimate the NOx emissions at the unreachable high engine power conditions. As the results, the NOx emissions are found to be a strong function of combustion inlet air temperature and fuel air equivalence ratio but a weaker function of inlet air pressure. With these three equations, the NOx emissions performance of this injector concept is calculated as a 66% reduction relative to the ICAO CAEP-6 standard using a 55:1 pressure-ratio engine cycle. Uncertainty in the NOx emissions estimation increases as the extrapolation range departs from the experimental conditions. Since maximum inlet air pressure tested was less than 50% of the full power engine inlet air pressure, a future experiment at higher inlet air pressure conditions is needed to confirm the NOx emissions dependency on inlet air pressure.
NOx Emissions Performance and Correlation Equations for a Multipoint LDI Injector
NASA Technical Reports Server (NTRS)
He, Zhuohui J.; Chang, Clarence T.; Follen, Caitlin E.
2014-01-01
Lean Direct Injection (LDI) is a combustor concept that reduces nitrogen oxides (NOx) emissions. This paper looks at a 3-zone multipoint LDI concept developed by Parker Hannifin Corporation. The concept was tested in a flame-tube test facility at NASA Glenn Research Center. Due to test facility limitations, such as inlet air temperature and pressure, the flame-tube test was not able to cover the full set of engine operation conditions. Three NOx correlation equations were developed based on assessing NOx emissions dependencies on inlet air pressure (P3), inlet air temperature (T3), and fuel air equivalence ratio (?) to estimate the NOx emissions at the unreachable high engine power conditions. As the results, the NOx emissions are found to be a strong function of combustion inlet air temperature and fuel air equivalence ratio but a weaker function of inlet air pressure. With these three equations, the NOx emissions performance of this injector concept is calculated as a 66 percent reduction relative to the ICAO CAEP-6 standard using a 55:1 pressure-ratio engine cycle. Uncertainty in the NOx emissions estimation increases as the extrapolation range departs from the experimental conditions. Since maximum inlet air pressure tested was less than 50 percent of the full power engine inlet air pressure, a future experiment at higher inlet air pressure conditions is needed to confirm the NOx emissions dependency on inlet air pressure.
Newman, Phil; Adams, Roger; Waddington, Gordon
2012-09-01
To examine the relationship between two clinical test results and future diagnosis of (Medial Tibial Stress Syndrome) MTSS in personnel at a military trainee establishment. Data from a preparticipation musculoskeletal screening test performed on 384 Australian Defence Force Academy Officer Cadets were compared against 693 injuries reported by 326 of the Officer Cadets in the following 16 months. Data were held in an Injury Surveillance database and analysed using χ² and Fisher's Exact tests, and Receiver Operating Characteristic Curve analysis. Diagnosis of MTSS, confirmed by an independent blinded health practitioner. Both the palpation and oedema clinical tests were each found to be significant predictors for later onset of MTSS. Specifically: Shin palpation test OR 4.63, 95% CI 2.5 to 8.5, Positive Likelihood Ratio 3.38, Negative Likelihood Ratio 0.732, Pearson χ² p<0.001; Shin oedema test OR 76.1 95% CI 9.6 to 602.7, Positive Likelihood Ratio 7.26, Negative Likelihood Ratio 0.095, Fisher's Exact p<0.001; Combined Shin Palpation Test and Shin Oedema Test Positive Likelihood Ratio 7.94, Negative Likelihood Ratio <0.001, Fisher's Exact p<0.001. Female gender was found to be an independent risk factor (OR 2.97, 95% CI 1.66 to 5.31, Positive Likelihood Ratio 2.09, Negative Likelihood Ratio 0.703, Pearson χ² p<0.001) for developing MTSS. The tests for MTSS employed here are components of a normal clinical examination used to diagnose MTSS. This paper confirms that these tests and female gender can also be confidently applied in predicting those in an asymptomatic population who are at greater risk of developing MTSS symptoms with activity at some point in the future.
Morshedi-Meibodi, Ali; Larson, Martin G; Levy, Daniel; O'Donnell, Christopher J; Vasan, Ramachandran S
2002-10-15
A delayed heart rate (HR) recovery after graded exercise testing has been associated with increased all-cause mortality in clinic-based samples. No prior study has examined the association of HR recovery after exercise with the incidence of coronary heart disease (CHD) and cardiovascular disease (CVD) events. We evaluated 2,967 Framingham study subjects (1,400 men, mean age 43 years) who were free of CVD and underwent a treadmill exercise test (Bruce protocol) at a routine examination. We examined the relations of HR recovery indexes (decrease in HR from peak exercise) to the incidence of a first CHD or CVD event and all-cause mortality, adjusting for established CVD risk factors. During follow-up (mean 15 years), 214 subjects experienced a CHD event (156 men), 312 developed a CVD event (207 men), and 167 died (105 men). In multivariable models, continuous HR recovery indexes were not associated with the incidence of CHD or CVD events, or with all-cause mortality. However, in models evaluating quintile-based cut points, the top quintile of HR recovery (greatest decline in HR) at 1-minute after exercise was associated with a lower risk of CHD (hazards ratio vs bottom 4 quintiles 0.54, 95% confidence interval [CI], 0.32 to 0.93) and CVD (hazards ratio 0.61, 95% CI 0.41 to 0.93), but not all-cause mortality (hazards ratio 0.99, 95% CI 0.60 to 1.62). In our community-based sample, HR recovery indexes were not associated with all-cause mortality. A very rapid HR recovery immediately after exercise was associated with lower risk of CHD and CVD events. These findings should be confirmed in other settings.
Neutron collimator design of neutron radiography based on the BNCT facility
NASA Astrophysics Data System (ADS)
Yang, Xiao-Peng; Yu, Bo-Xiang; Li, Yi-Guo; Peng, Dan; Lu, Jin; Zhang, Gao-Long; Zhao, Hang; Zhang, Ai-Wu; Li, Chun-Yang; Liu, Wan-Jin; Hu, Tao; Lü, Jun-Guang
2014-02-01
For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy (BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106 n/cm2/s, the maximum collimation ratio (L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography.
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies
Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.
Erdoğan, Semra; Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.
Neutron measurements of stresses in a test artifact produced by laser-based additive manufacturing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gnäupel-Herold, Thomas; Slotwinski, John; Moylan, Shawn
2014-02-18
A stainless steel test artifact produced by Direct Metal Laser Sintering and similar to a proposed standardized test artifact was examined using neutron diffraction. The artifact contained a number of structures with different aspect ratios pertaining to wall thickness, height above base plate, and side length. Through spatial resolutions of the order of one millimeter the volumetric distribution of stresses in several was measured. It was found that the stresses peak in the tensile region around 500 MPa near the top surface, with balancing compressive stresses in the interior. The presence of a support structure (a one millimeter high, thinmore » walled, hence weaker, lattice structure deposited on the base plate, followed by a fully dense AM structure) has only minor effects on the stresses.« less
Kavaliauskas, Mykolas; Aspe, Rodrigo R; Babraj, John
2015-08-01
The work-to-rest ratio during cycling-based high-intensity interval training (HIT) could be important in regulating physiological and performance adaptations. We sought to determine the effectiveness of cycling-based HIT with different work-to-rest ratios for long-distance running. Thirty-two long-distance runners (age: 39 ± 8 years; sex: 14 men, 18 women; average weekly running training volume: 25 miles) underwent baseline testing (3-km time-trial, V[Combining Dot Above]O2peak and time to exhaustion, and Wingate test) before a 2-week matched-work cycling HIT of 6 × 10-second sprints with different rest periods (30 seconds [R30], 80 seconds [R80], 120 seconds [R120], or control). Three-kilometer time trial was significantly improved in the R30 group only (3.1 ± 4.0%, p = 0.04), whereas time to exhaustion was significantly increased in the 2 groups with a lower work-to-rest ratio (R30 group 6.4 ± 6.3%, p = 0.003 vs. R80 group 4.4 ± 2.7%, p = 0.03 vs. R120 group 1.9 ± 5.0%, p = 0.2). However, improvements in average power production were significantly greater with a higher work-to-rest ratio (R30 group 0.3 ± 4.1%, p = 0.8 vs. R80 group 4.6 ± 4.2%, p = 0.03 vs. R120 group 5.3 ± 5.9%, p = 0.02), whereas peak power significantly increased only in the R80 group (8.5 ± 8.2%, p = 0.04) but not in the R30 group (4.3 ± 6.1%, p = 0.3) or in the R120 group (7.1 ± 7.9%, p = 0.09). Therefore, cycling-based HIT is an effective way to improve running performance, and the type and magnitude of adaptation is dependent on the work-to-rest ratio.
Syngas production by chemical-looping gasification of wheat straw with Fe-based oxygen carrier.
Hu, Jianjun; Li, Chong; Guo, Qianhui; Dang, Jiatao; Zhang, Quanguo; Lee, Duu-Jong; Yang, Yunlong
2018-05-03
The iron-based oxygen carriers (OC's), Fe 2 O 3 /support (Al 2 O 3 , TiO 2 , SiO 2 and ZrO 2 ), for chemical looping gasification of wheat straw were prepared using impregnation method. The surface morphology, crystal structure, carbon deposition potential, lattice oxygen activity and selectivity of the yielded OCs were examined. The Fe 2 O 3 /Al 2 O 3 OCs at 60% loading has the highest H 2 yield, H 2 /CO ratio, gas yield, and carbon conversion amongst the tested OC's. Parametric studies revealed that an optimal loading Fe 2 O 3 of 60%, steam-to-biomass ratio of 0.8 and oxygen carrier-to-biomass ratio of 1.0 led to the maximum H 2 /CO ratio, gas yield, H 2 + CO ratio, and carbon conversion from the gasified wheat straw. High temperature, up to 950 °C, enhanced the gasification performance. A kinetic network interpreted the noted experimental results. The lattice oxygen provided by the prepared Fe 2 O 3 /Al 2 O 3 oxygen carriers promotes chemical looping gasification efficiencies from wheat straw. Copyright © 2018 Elsevier Ltd. All rights reserved.
Interactive flutter analysis and parametric study for conceptual wing design
NASA Technical Reports Server (NTRS)
Mukhopadhyay, Vivek
1995-01-01
An interactive computer program was developed for wing flutter analysis in the conceptual design stage. The objective was to estimate the flutter instability boundary of a flexible cantilever wing, when well defined structural and aerodynamic data are not available, and then study the effect of change in Mach number, dynamic pressure, torsional frequency, sweep, mass ratio, aspect ratio, taper ratio, center of gravity, and pitch inertia, to guide the development of the concept. The software was developed on MathCad (trademark) platform for Macintosh, with integrated documentation, graphics, database and symbolic mathematics. The analysis method was based on nondimensional parametric plots of two primary flutter parameters, namely Regier number and Flutter number, with normalization factors based on torsional stiffness, sweep, mass ratio, aspect ratio, center of gravity location and pitch inertia radius of gyration. The plots were compiled in a Vaught Corporation report from a vast database of past experiments and wind tunnel tests. The computer program was utilized for flutter analysis of the outer wing of a Blended Wing Body concept, proposed by McDonnell Douglas Corporation. Using a set of assumed data, preliminary flutter boundary and flutter dynamic pressure variation with altitude, Mach number and torsional stiffness were determined.
Similarity regularized sparse group lasso for cup to disc ratio computation.
Cheng, Jun; Zhang, Zhuo; Tao, Dacheng; Wong, Damon Wing Kee; Liu, Jiang; Baskaran, Mani; Aung, Tin; Wong, Tien Yin
2017-08-01
Automatic cup to disc ratio (CDR) computation from color fundus images has shown to be promising for glaucoma detection. Over the past decade, many algorithms have been proposed. In this paper, we first review the recent work in the area and then present a novel similarity-regularized sparse group lasso method for automated CDR estimation. The proposed method reconstructs the testing disc image based on a set of reference disc images by integrating the similarity between testing and the reference disc images with the sparse group lasso constraints. The reconstruction coefficients are then used to estimate the CDR of the testing image. The proposed method has been validated using 650 images with manually annotated CDRs. Experimental results show an average CDR error of 0.0616 and a correlation coefficient of 0.7, outperforming other methods. The areas under curve in the diagnostic test reach 0.843 and 0.837 when manual and automatically segmented discs are used respectively, better than other methods as well.
NASA Astrophysics Data System (ADS)
Mandal, Shyamapada; Santhi, B.; Sridhar, S.; Vinolia, K.; Swaminathan, P.
2017-06-01
In this paper, an online fault detection and classification method is proposed for thermocouples used in nuclear power plants. In the proposed method, the fault data are detected by the classification method, which classifies the fault data from the normal data. Deep belief network (DBN), a technique for deep learning, is applied to classify the fault data. The DBN has a multilayer feature extraction scheme, which is highly sensitive to a small variation of data. Since the classification method is unable to detect the faulty sensor; therefore, a technique is proposed to identify the faulty sensor from the fault data. Finally, the composite statistical hypothesis test, namely generalized likelihood ratio test, is applied to compute the fault pattern of the faulty sensor signal based on the magnitude of the fault. The performance of the proposed method is validated by field data obtained from thermocouple sensors of the fast breeder test reactor.
NASA Technical Reports Server (NTRS)
Hair, L. M.
1975-01-01
The aerodynamic effects of plumes from hot combustion gases in the presence of a transonic external flow field were measured to advance plumes simulation technology, extend a previously acquired data base, and provide data to compare with the effects observed using cold gas plumes. A variety of underexpanded plumes issuing from the base of a strut-mounted ogive-cylinder body were produced by combusting solid propellant gas generators. The gas generator fired in a short-duration mode (200 to 300 msec). Propellants containing 16 percent and 2 percent A1 were used, with chamber pressures from 400 to 1800 psia. Conical nozzles of 15 deg half-angle were tested with area ratios of 4 and 8. Pressures were measured in the gas generator combustion chamber, along the nozzle wall, on the base, and along the body rear exterior. Schlieren photographs were taken for all tests. Test data are presented along with a description of the test setup and procedures.
Experimental Investigation of A Twin Shaft Micro Gas-Turbine System
NASA Astrophysics Data System (ADS)
Sadig, Hussain; Sulaiman, Shaharin Anwar; Ibrahim, Idris
2013-06-01
Due to the fast depletion of fossil fuels and its negative impact on the environment, more attention has been concentrated to find new resources, policies and technologies, which meet the global needs with regard to fuel sustainability and emissions. In this paper, as a step to study the effect of burning low calorific value fuels on gas-turbine performance; a 50 kW slightly pressurized non-premixed tubular combustor along with turbocharger based twin shaft micro gas-turbine was designed and fabricated. A series of tests were conducted to characterize the system using LPG fuel. The tests include the analysis of the temperature profile, pressure and combustor efficiency as well as air fuel ratio and speed of the second turbine. The tests showed a stable operation with acceptable efficiency, air fuel ratio, and temperature gradient for the single and twin shaft turbines.
The Mach number of the cosmic flow - A critical test for current theories
NASA Technical Reports Server (NTRS)
Ostriker, Jeremiah P.; Suto, Yusushi
1990-01-01
A new cosmological, self-contained test using the ratio of mean velocity and the velocity dispersion in the mean flow frame of a group of test objects is presented. To allow comparison with linear theory, the velocity field must first be smoothed on a suitable scale. In the context of linear perturbation theory, the Mach number M(R) which measures the ratio of power on scales larger than to scales smaller than the patch size R, is independent of the perturbation amplitude and also of bias. An apparent inconsistency is found for standard values of power-law index n = 1 and cosmological density parameter Omega = 1, when comparing values of M(R) predicted by popular models with tentative available observations. Nonstandard models based on adiabatic perturbations with either negative n or small Omega value also fail, due to creation of unacceptably large microwave background fluctuations.
Sequential Probability Ratio Test for Spacecraft Collision Avoidance Maneuver Decisions
NASA Technical Reports Server (NTRS)
Carpenter, J. Russell; Markley, F. Landis
2013-01-01
A document discusses sequential probability ratio tests that explicitly allow decision-makers to incorporate false alarm and missed detection risks, and are potentially less sensitive to modeling errors than a procedure that relies solely on a probability of collision threshold. Recent work on constrained Kalman filtering has suggested an approach to formulating such a test for collision avoidance maneuver decisions: a filter bank with two norm-inequality-constrained epoch-state extended Kalman filters. One filter models the null hypotheses that the miss distance is inside the combined hard body radius at the predicted time of closest approach, and one filter models the alternative hypothesis. The epoch-state filter developed for this method explicitly accounts for any process noise present in the system. The method appears to work well using a realistic example based on an upcoming, highly elliptical orbit formation flying mission.
Protocol for Cohesionless Sample Preparation for Physical Experimentation
2016-05-01
protocol for specimen preparation that will enable the use of soil strength curves based on expedient field classification testing (e.g., grain-size...void ratio and relative compaction, which compares field compaction to a laboratory maximum density. Gradation charts for the two materials used in...the failure stress. Ring shear testing was performed using the GCTS Residual-Ring Shear System SRS-150 in order to measure the peak torsional
Two-dimensional computational modeling of high-speed transient flow in gun tunnel
NASA Astrophysics Data System (ADS)
Mohsen, A. M.; Yusoff, M. Z.; Hasini, H.; Al-Falahi, A.
2018-03-01
In this work, an axisymmetric numerical model was developed to investigate the transient flow inside a 7-meter-long free piston gun tunnel. The numerical solution of the gun tunnel was carried out using the commercial solver Fluent. The governing equations of mass, momentum, and energy were discretized using the finite volume method. The dynamic zone of the piston was modeled as a rigid body, and its motion was coupled with the hydrodynamic forces from the flow solution based on the six-degree-of-freedom solver. A comparison of the numerical data with the theoretical calculations and experimental measurements of a ground-based gun tunnel facility showed good agreement. The effects of parameters such as working gases and initial pressure ratio on the test conditions in the facility were examined. The pressure ratio ranged from 10 to 50, and gas combinations of air-air, helium-air, air-nitrogen, and air-CO2 were used. The results showed that steady nozzle reservoir conditions can be maintained for a longer duration when the initial conditions across the diaphragm are adjusted. It was also found that the gas combination of helium-air yielded the highest shock wave strength and speed, but a longer test time was achieved in the test section when using the CO2 test gas.
30 CFR 7.87 - Test to determine the maximum fuel-air ratio.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Test to determine the maximum fuel-air ratio. 7... Use in Underground Coal Mines § 7.87 Test to determine the maximum fuel-air ratio. (a) Test procedure... range that will be used during this test. (3) While running the engine, the following shall apply: (i...
30 CFR 7.87 - Test to determine the maximum fuel-air ratio.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Test to determine the maximum fuel-air ratio. 7... Use in Underground Coal Mines § 7.87 Test to determine the maximum fuel-air ratio. (a) Test procedure... range that will be used during this test. (3) While running the engine, the following shall apply: (i...
30 CFR 7.87 - Test to determine the maximum fuel-air ratio.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Test to determine the maximum fuel-air ratio. 7... Use in Underground Coal Mines § 7.87 Test to determine the maximum fuel-air ratio. (a) Test procedure... range that will be used during this test. (3) While running the engine, the following shall apply: (i...
30 CFR 7.87 - Test to determine the maximum fuel-air ratio.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Test to determine the maximum fuel-air ratio. 7... Use in Underground Coal Mines § 7.87 Test to determine the maximum fuel-air ratio. (a) Test procedure... range that will be used during this test. (3) While running the engine, the following shall apply: (i...
30 CFR 7.87 - Test to determine the maximum fuel-air ratio.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Test to determine the maximum fuel-air ratio. 7... Use in Underground Coal Mines § 7.87 Test to determine the maximum fuel-air ratio. (a) Test procedure... range that will be used during this test. (3) While running the engine, the following shall apply: (i...
Aspect ratio has no effect on genotoxicity of multi-wall carbon nanotubes.
Kim, Jin Sik; Lee, Kyu; Lee, Young Hee; Cho, Hyun Sun; Kim, Ki Heon; Choi, Kyung Hee; Lee, Sang Hee; Song, Kyung Seuk; Kang, Chang Soo; Yu, Il Je
2011-07-01
Carbon nanotubes (CNTs) have specific physico-chemical and electrical properties that are useful for telecommunications, medicine, materials, manufacturing processes and the environmental and energy sectors. Yet, despite their many advantages, it is also important to determine whether CNTs may represent a hazard to the environment and human health. Like asbestos, the aspect ratio (length:diameter) and metal components of CNTs are known to have an effect on the toxicity of carbon nanotubes. Thus, to evaluate the toxic potential of CNTs in relation to their aspect ratio and metal contamination, in vivo and in vitro genotoxicity tests were conducted using high-aspect-ratio (diameter: 10-15 nm, length: ~10 μm) and low-aspect-ratio multi-wall carbon nanotubes (MWCNTs, diameter: 10-15 nm, length: ~150 nm) according to OECD test guidelines 471 (bacterial reverse mutation test), 473 (in vitro chromosome aberration test), and 474 (in vivo micronuclei test) with a good laboratory practice system. To determine the treatment concentration for all the tests, a solubility and dispersive test was performed, and a 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) solution found to be more suitable than distilled water. Neither the high- nor the low-aspect-ratio MWCNTs induced any genotoxicity in a bacterial reverse mutation test (~1,000 μg/plate), in vitro chromosome aberration test (without S9: ~6.25 μg/ml, with S9: ~50 μg/ml), or in vivo micronuclei test (~50 mg/kg). However, the high-aspect-ratio MWCNTs were found to be more toxic than the low-aspect-ratio MWCNTs. Thus, while high-aspect-ratio MWCNTs do not induce direct genotoxicity or metabolic activation-mediated genotoxicity, genotoxicity could still be induced indirectly through oxidative stress or inflammation.
Litster, Annette; Lin, Jui-Ming; Nichols, Jamieson; Weng, Hsin-Yi
2014-06-04
Antibody testing based on individual risk assessments is recommended to determine feline immunodeficiency virus (FIV) status, but ELISA and Western blot tests cannot distinguish between anti-FIV antibodies produced in response to natural infection and those produced in response to FIV vaccination. The aim of this cross-sectional study was to test the hypothesis that FIV-infected cats could be differentiated from FIV-vaccinated uninfected cats using lymphocyte subset results, specifically the CD4%:CD8(low)% T-lymphocyte ratio. Comparisons of the CD4%:CD8(low)% T-lymphocyte ratio were made among the following four groups: Group 1 - FIV-infected cats (n=61; FIV-antibody positive by ELISA and FIV PCR positive); Group 2 - FIV-uninfected cats (n=96; FIV-antibody negative by ELISA); Group 3 - FIV-vaccinated uninfected cats (n=31; FIV-antibody negative by ELISA before being vaccinated against FIV, after which they tested FIV ELISA positive); and Group 4 - FIV-uninfected but under chronic/active antigenic stimulation (n=16; FIV-antibody negative by ELISA; all had active clinical signs of either upper respiratory tract disease or gingival disease for ≥ 21 days). The median CD4%:CD8(low)% T-lymphocyte ratio was lower in Group 1 (1.39) than in each of the other three groups (Group 2 - 9.77, Group 3 - 9.72, Group 4 - 5.64; P<0.05). The CD4%:CD8(low)% T-lymphocyte ratio was also the most effective discriminator between FIV-infected cats and the other three groups, and areas under ROC curves ranged from 0.91 (compared with Group 4) to 0.96 (compared with Group 3). CD4%:CD8(low)% shows promise as an effective test to differentiate between FIV-infected cats and FIV-vaccinated uninfected cats. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Hendershot, K. C.
1977-01-01
A 2.25% scale model of the space shuttle external tank and solid rocket boosters was tested in the NASA/Ames Unitary 11 x 11 foot transonic and 9 x 7 foot supersonic tunnels to obtain base pressure data with firing solid propellant exhaust plumes. Data system difficulties prevented the acquisition of any useful data in the 9 x 7 tunnel. However, 28 successful rocket test firings were made in the 11 x 11 tunnel, providing base pressure data at Mach numbers of 0.5, 0.9, 1.05, 1.2, and 1.3 and at plume pressure ratios ranging from 11 to 89.
Sull, Jae Woong; Liang, Kung-Yee; Hetmanski, Jacqueline B.; Fallin, M. Daniele; Ingersoll, Roxanne G.; Park, Ji Wan; Wu-Chou, Yah-Huei; Chen, Philip K.; Chong, Samuel S.; Cheah, Felicia; Yeow, Vincent; Park, Beyoung Yun; Jee, Sun Ha; Jabs, Ethylin W.; Redett, Richard; Scott, Alan F.; Beaty, Terri H.
2009-01-01
Isolated cleft palate is among the most common human birth defects. The TCOF1 gene has been suggested as a candidate gene for cleft palate based on animal models. This study tests for association between markers in TCOF1 and isolated, nonsyndromic cleft palate using a case-parent trio design considering parent-of-origin effects. Case-parent trios from three populations (comprising a total of 81 case-parent trios) were genotyped for single nucleotide polymorphisms (SNPs) in the TCOF1 gene. We used the transmission disequilibrium test and the transmission asymmetry test on individual SNPs. When all trios were combined, the odds ratio for transmission of the minor allele, OR(transmission), was significant for SNP rs15251 (OR = 2.88, P = 0.007), as well as rs2255796 and rs2569062 (OR = 2.08, P = 0.03; OR = 2.43, P = 0.041; respectively) when parent of origin was not considered. The transmission asymmetry test also revealed one SNP (rs15251) showing excess maternal transmission significant at the P = 0.005 level (OR = 6.50). Parent-of-origin effects were assessed using the parent-of-origin likelihood ratio test on both SNPs and haplotypes. While the parent-of-origin likelihood ratio test was only marginally significant for this SNP (P = 0.136), analysis of haplotypes of rs2255796 and rs15251 suggested excess maternal transmission. Therefore, these data suggest TCOF1 may influence risk of cleft palate through a parent-of-origin effect. PMID:18688869
NASA Technical Reports Server (NTRS)
Blair, A. B., Jr.; Stallings, R. L., Jr.
1986-01-01
A wind-tunnel investigation has been conducted at Mach numbers of 1.50, 2.16, and 2.86 to obtain axial-force data on a metric rectangular-box cavity with various length-to-depth ratios. The model was tested at angles of attack from -4 deg to -2 deg. The results are summarized to show variations in cavity axial-force coefficient for deep- and shallow-cavity configurations with detached and attached cavity flow fields, respectively. The results of the investigation indicate that for a wide range of cavity lengths and depths, good correlations of the cavity axial-force coefficients (based on cavity rear-face area) are obtained when these coefficients are plotted as a function of cavity length-to-depth ratio. Abrupt increases in the cavity axial-force coefficients at an angle of attack of 0 deg. reflect the transition from an open (detached) cavity flow field to a closed (attached) cavity flow field. Cavity length-to-depth ratio is the dominant factor affecting the switching of the cavity flow field from one type to the other. The type of cavity flow field (open or closed) is not dependent on the test angles of attack except near the critical value of length-to-depth ratio.
The effects of leading edge and downstream film cooling on turbine vane heat transfer
NASA Astrophysics Data System (ADS)
Hylton, L. D.; Nirmalan, V.; Sultanian, B. K.; Kaufman, R. M.
1988-11-01
The progress under contract NAS3-24619 toward the goal of establishing a relevant data base for use in improving the predictive design capabilities for external heat transfer to turbine vanes, including the effect of downstream film cooling with and without leading edge showerhead film cooling. Experimental measurements were made in a two-dimensional cascade previously used to obtain vane surface heat transfer distributions on nonfilm cooled airfoils under contract NAS3-22761 and leading edge showerhead film cooled airfoils under contract NAS3-23695. The principal independent parameters (Mach number, Reynolds number, turbulence, wall-to-gas temperature ratio, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio) were maintained over ranges consistent with actual engine conditions and the test matrix was structured to provide an assessment of the independent influence of parameters of interest, namely, exit Mach number, exit Reynolds number, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio. Data provide a data base for downstream film cooled turbine vanes and extends the data bases generated in the two previous studies. The vane external heat transfer obtained indicate that considerable cooling benefits can be achieved by utilizing downstream film cooling. The data obtained and presented illustrate the interaction of the variables and should provide the airfoil designer and computational analyst the information required to improve heat transfer design capabilities for film cooled turbine airfoils.
The effects of leading edge and downstream film cooling on turbine vane heat transfer
NASA Technical Reports Server (NTRS)
Hylton, L. D.; Nirmalan, V.; Sultanian, B. K.; Kaufman, R. M.
1988-01-01
The progress under contract NAS3-24619 toward the goal of establishing a relevant data base for use in improving the predictive design capabilities for external heat transfer to turbine vanes, including the effect of downstream film cooling with and without leading edge showerhead film cooling. Experimental measurements were made in a two-dimensional cascade previously used to obtain vane surface heat transfer distributions on nonfilm cooled airfoils under contract NAS3-22761 and leading edge showerhead film cooled airfoils under contract NAS3-23695. The principal independent parameters (Mach number, Reynolds number, turbulence, wall-to-gas temperature ratio, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio) were maintained over ranges consistent with actual engine conditions and the test matrix was structured to provide an assessment of the independent influence of parameters of interest, namely, exit Mach number, exit Reynolds number, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio. Data provide a data base for downstream film cooled turbine vanes and extends the data bases generated in the two previous studies. The vane external heat transfer obtained indicate that considerable cooling benefits can be achieved by utilizing downstream film cooling. The data obtained and presented illustrate the interaction of the variables and should provide the airfoil designer and computational analyst the information required to improve heat transfer design capabilities for film cooled turbine airfoils.
Testing new methodologies for short -term earthquake forecasting: Multi-parameters precursors
NASA Astrophysics Data System (ADS)
Ouzounov, Dimitar; Pulinets, Sergey; Tramutoli, Valerio; Lee, Lou; Liu, Tiger; Hattori, Katsumi; Kafatos, Menas
2014-05-01
We are conducting real-time tests involving multi-parameter observations over different seismo-tectonics regions in our investigation of phenomena preceding major earthquakes. Our approach is based on a systematic analysis of several selected parameters, namely: gas discharge; thermal infrared radiation; ionospheric electron density; and atmospheric temperature and humidity, which we believe are all associated with the earthquake preparation phase. We are testing a methodology capable to produce alerts in advance of major earthquakes (M > 5.5) in different regions of active earthquakes and volcanoes. During 2012-2013 we established a collaborative framework with PRE-EARTHQUAKE (EU) and iSTEP3 (Taiwan) projects for coordinated measurements and prospective validation over seven testing regions: Southern California (USA), Eastern Honshu (Japan), Italy, Greece, Turkey, Taiwan (ROC), Kamchatka and Sakhalin (Russia). The current experiment provided a "stress test" opportunity to validate the physical based earthquake precursor approach over regions of high seismicity. Our initial results are: (1) Real-time tests have shown the presence of anomalies in the atmosphere and ionosphere before most of the significant (M>5.5) earthquakes; (2) False positives exist and ratios are different for each region, varying between 50% for (Southern Italy), 35% (California) down to 25% (Taiwan, Kamchatka and Japan) with a significant reduction of false positives as soon as at least two geophysical parameters are contemporarily used; (3) Main problems remain related to the systematic collection and real-time integration of pre-earthquake observations. Our findings suggest that real-time testing of physically based pre-earthquake signals provides a short-term predictive power (in all three important parameters, namely location, time and magnitude) for the occurrence of major earthquakes in the tested regions and this result encourages testing to continue with a more detailed analysis of false alarm ratios and understanding of the overall physics of earthquake preparation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... subclassification within a test group which is based on engine code, transmission type and gear ratios, final drive... the non-combustion reaction of a consumable fuel, typically hydrogen. Fuel cell electric vehicle means...-groups in each regulatory category to which fuel consumption requirements apply, and are defined as...
Si, Guo-Ning; Chen, Lan; Li, Bao-Guo
2014-04-01
Base on the Kawakita powder compression equation, a general theoretical model for predicting the compression characteristics of multi-components pharmaceutical powders with different mass ratios was developed. The uniaxial flat-face compression tests of powder lactose, starch and microcrystalline cellulose were carried out, separately. Therefore, the Kawakita equation parameters of the powder materials were obtained. The uniaxial flat-face compression tests of the powder mixtures of lactose, starch, microcrystalline cellulose and sodium stearyl fumarate with five mass ratios were conducted, through which, the correlation between mixture density and loading pressure and the Kawakita equation curves were obtained. Finally, the theoretical prediction values were compared with experimental results. The analysis showed that the errors in predicting mixture densities were less than 5.0% and the errors of Kawakita vertical coordinate were within 4.6%, which indicated that the theoretical model could be used to predict the direct compaction characteristics of multi-component pharmaceutical powders.
Feasibility test of a solid state spin-scan photo-imaging system
NASA Technical Reports Server (NTRS)
Laverty, N. P.
1973-01-01
The feasibility of using a solid-state photo-imaging system to obtain resolution imagery from a Pioneer-type spinning spacecraft in future exploratory missions to the outer planets is discussed. Evaluation of the photo-imaging system performance, based on electrical video signal analysis recorded on magnetic tape, shows that the signal-to-noise (S/N) ratios obtained at low spatial frequencies exceed the anticipated performance and that measured modulation transfer functions exhibited some degradation in comparison with the estimated values, primarily owing to the difficulty in obtaining a precise focus of the optical system in the laboratory with the test patterns in close proximity to the objective lens. A preliminary flight model design of the photo-imaging system is developed based on the use of currently available phototransistor arrays. Image quality estimates that will be obtained are presented in terms of S/N ratios and spatial resolution for the various planets and satellites. Parametric design tradeoffs are also defined.
The evaluation of the OSGLR algorithm for restructurable controls
NASA Technical Reports Server (NTRS)
Bonnice, W. F.; Wagner, E.; Hall, S. R.; Motyka, P.
1986-01-01
The detection and isolation of commercial aircraft control surface and actuator failures using the orthogonal series generalized likelihood ratio (OSGLR) test was evaluated. The OSGLR algorithm was chosen as the most promising algorithm based on a preliminary evaluation of three failure detection and isolation (FDI) algorithms (the detection filter, the generalized likelihood ratio test, and the OSGLR test) and a survey of the literature. One difficulty of analytic FDI techniques and the OSGLR algorithm in particular is their sensitivity to modeling errors. Therefore, methods of improving the robustness of the algorithm were examined with the incorporation of age-weighting into the algorithm being the most effective approach, significantly reducing the sensitivity of the algorithm to modeling errors. The steady-state implementation of the algorithm based on a single cruise linear model was evaluated using a nonlinear simulation of a C-130 aircraft. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling the linear models used by the algorithm on dynamic pressure and flap deflection was also considered. Since simply scheduling the linear models over the entire flight envelope is unlikely to be adequate, scheduling of the steady-state implentation of the algorithm was briefly investigated.
Tsalik, Ephraim L; Li, Yanhong; Hudson, Lori L; Chu, Vivian H; Himmel, Tiffany; Limkakeng, Alex T; Katz, Jason N; Glickman, Seth W; McClain, Micah T; Welty-Wolf, Karen E; Fowler, Vance G; Ginsburg, Geoffrey S; Woods, Christopher W; Reed, Shelby D
2016-03-01
Limitations in methods for the rapid diagnosis of hospital-acquired infections often delay initiation of effective antimicrobial therapy. New diagnostic approaches offer potential clinical and cost-related improvements in the management of these infections. We developed a decision modeling framework to assess the potential cost-effectiveness of a rapid biomarker assay to identify hospital-acquired infection in high-risk patients earlier than standard diagnostic testing. The framework includes parameters representing rates of infection, rates of delayed appropriate therapy, and impact of delayed therapy on mortality, along with assumptions about diagnostic test characteristics and their impact on delayed therapy and length of stay. Parameter estimates were based on contemporary, published studies and supplemented with data from a four-site, observational, clinical study. Extensive sensitivity analyses were performed. The base-case analysis assumed 17.6% of ventilated patients and 11.2% of nonventilated patients develop hospital-acquired infection and that 28.7% of patients with hospital-acquired infection experience delays in appropriate antibiotic therapy with standard care. We assumed this percentage decreased by 50% (to 14.4%) among patients with true-positive results and increased by 50% (to 43.1%) among patients with false-negative results using a hypothetical biomarker assay. Cost of testing was set at $110/d. In the base-case analysis, among ventilated patients, daily diagnostic testing starting on admission reduced inpatient mortality from 12.3 to 11.9% and increased mean costs by $1,640 per patient, resulting in an incremental cost-effectiveness ratio of $21,389 per life-year saved. Among nonventilated patients, inpatient mortality decreased from 7.3 to 7.1% and costs increased by $1,381 with diagnostic testing. The resulting incremental cost-effectiveness ratio was $42,325 per life-year saved. Threshold analyses revealed the probabilities of developing hospital-acquired infection in ventilated and nonventilated patients could be as low as 8.4 and 9.8%, respectively, to maintain incremental cost-effectiveness ratios less than $50,000 per life-year saved. Development and use of serial diagnostic testing that reduces the proportion of patients with delays in appropriate antibiotic therapy for hospital-acquired infections could reduce inpatient mortality. The model presented here offers a cost-effectiveness framework for future test development.
Quantitative analysis of comparative genomic hybridization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manoir, S. du; Bentz, M.; Joos, S.
1995-01-01
Comparative genomic hybridization (CGH) is a new molecular cytogenetic method for the detection of chromosomal imbalances. Following cohybridization of DNA prepared from a sample to be studied and control DNA to normal metaphase spreads, probes are detected via different fluorochromes. The ratio of the test and control fluorescence intensities along a chromosome reflects the relative copy number of segments of a chromosome in the test genome. Quantitative evaluation of CGH experiments is required for the determination of low copy changes, e.g., monosomy or trisomy, and for the definition of the breakpoints involved in unbalanced rearrangements. In this study, a programmore » for quantitation of CGH preparations is presented. This program is based on the extraction of the fluorescence ratio profile along each chromosome, followed by averaging of individual profiles from several metaphase spreads. Objective parameters critical for quantitative evaluations were tested, and the criteria for selection of suitable CGH preparations are described. The granularity of the chromosome painting and the regional inhomogeneity of fluorescence intensities in metaphase spreads proved to be crucial parameters. The coefficient of variation of the ratio value for chromosomes in balanced state (CVBS) provides a general quality criterion for CGH experiments. Different cutoff levels (thresholds) of average fluorescence ratio values were compared for their specificity and sensitivity with regard to the detection of chromosomal imbalances. 27 refs., 15 figs., 1 tab.« less
Pan, Hui; Ba-Thein, William
2018-01-01
Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.
Assessing Binocular Interaction in Amblyopia and Its Clinical Feasibility
Kwon, MiYoung; Lu, Zhong-Lin; Miller, Alexandra; Kazlas, Melanie; Hunter, David G.; Bex, Peter J.
2014-01-01
Purpose To measure binocular interaction in amblyopes using a rapid and patient-friendly computer-based method, and to test the feasibility of the assessment in the clinic. Methods Binocular interaction was assessed in subjects with strabismic amblyopia (n = 7), anisometropic amblyopia (n = 6), strabismus without amblyopia (n = 15) and normal vision (n = 40). Binocular interaction was measured with a dichoptic phase matching task in which subjects matched the position of a binocular probe to the cyclopean perceived phase of a dichoptic pair of gratings whose contrast ratios were systematically varied. The resulting effective contrast ratio of the weak eye was taken as an indicator of interocular imbalance. Testing was performed in an ophthalmology clinic under 8 mins. We examined the relationships between our binocular interaction measure and standard clinical measures indicating abnormal binocularity such as interocular acuity difference and stereoacuity. The test-retest reliability of the testing method was also evaluated. Results Compared to normally-sighted controls, amblyopes exhibited significantly reduced effective contrast (∼20%) of the weak eye, suggesting a higher contrast requirement for the amblyopic eye compared to the fellow eye. We found that the effective contrast ratio of the weak eye covaried with standard clincal measures of binocular vision. Our results showed that there was a high correlation between the 1st and 2nd measurements (r = 0.94, p<0.001) but without any significant bias between the two. Conclusions Our findings demonstrate that abnormal binocular interaction can be reliably captured by measuring the effective contrast ratio of the weak eye and quantitative assessment of binocular interaction is a quick and simple test that can be performed in the clinic. We believe that reliable and timely assessment of deficits in a binocular interaction may improve detection and treatment of amblyopia. PMID:24959842
Gengsheng Qin; Davis, Angela E; Jing, Bing-Yi
2011-06-01
For a continuous-scale diagnostic test, it is often of interest to find the range of the sensitivity of the test at the cut-off that yields a desired specificity. In this article, we first define a profile empirical likelihood ratio for the sensitivity of a continuous-scale diagnostic test and show that its limiting distribution is a scaled chi-square distribution. We then propose two new empirical likelihood-based confidence intervals for the sensitivity of the test at a fixed level of specificity by using the scaled chi-square distribution. Simulation studies are conducted to compare the finite sample performance of the newly proposed intervals with the existing intervals for the sensitivity in terms of coverage probability. A real example is used to illustrate the application of the recommended methods.
Foo, Jong Yong Abdiel
2008-01-01
Ankle brachial index is useful in monitoring the pathogenesis of peripheral arterial occlusive diseases. Sphygmomanometer is the standard instrument widely used but frequent prolonged monitoring can be less comfortable for patients. Pulse transit time is known to be inversely correlated with blood pressure and a ratio-based pulse transit time measurement has been proposed as a surrogate ankle brachial index marker. In this study, 17 normotensive adults (9 men; aged 25.4 +/- 3.9 years) were recruited. Two postural change test activities were performed to induce changes in the stiffness of the arterial wall of the moved periphery. Results showed that only readings from the limbs that adopted a new posture registered significant blood pressure and pulse transit time changes (P < .05). Furthermore, there was significant correlation between the ankle brachial index and pulse transit time ratio measure for both test activities (R(2) > or = 0.704). The findings herein suggest that pulse transit time ratio is a surrogate and accommodating ankle brachial index marker.
Low concentration ratio solar array for low Earth orbit multi-100kW application. Volume 2: Drawings
NASA Technical Reports Server (NTRS)
Nalbandian, S. J.; French, E. P.
1982-01-01
A preliminary design effort directed toward a low concentration ratio photovoltaic array system based on 1984 technology and capable of delivering multi-hundred kilowatts (300 kW to 100 kW range) in low Earth orbit. The array system consists of two or more array modules each capable of delivering between 113 kW to 175 kW using silicon solar cells or gallium arsenide solar cells, respectively. The array module deployed area is 1320 square meters and consists of 4356 pyramidal concentrator elements. The module, when stowed in the Space Shuttle's payload bay, has a stowage volume of a cube with 3.24 meters on a side. The concentrator elements are sized for a geometric concentration ratio (GCR) of six with an aperture area of 0.5 meters x 0.5 meters. Drawings for the preliminary design configuration and for the test hardware that was fabricated for design evaluation and test are provided.
Liu, Bingyu; Chen, Jiang; Zhang, Yiping
2016-01-01
In this study, two short precast concrete columns and two cast-in-situ concrete columns were tested under cyclic loads. It was shown that the sleeve grouted connection was equivalent to the cast-in-situ connections for short columns when the axial compression ratio was 0.6. In order to determine the influence of the axial compression ratio and the shear-span ratio on the shear capacity of the horizontal joint, a FE model was established and verified. The analysis showed that the axial compression ratio is advantageous to the joint and the shear capacity of the horizontal joint increases with increase of the shear-span ratio. Based on the results, the methods used to estimate the shear capacity of horizontal joints in the Chinese Specification and the Japanese Guidelines are discussed and it was found that both overestimated the shear capacity of the horizontal joint. In addition, the Chinese Specification failed to consider the influence of the shear-span ratio. PMID:27861493
Isotopic signature of atmospheric xenon released from light water reactors.
Kalinowski, Martin B; Pistner, Christoph
2006-01-01
A global monitoring system for atmospheric xenon radioactivity is being established as part of the International Monitoring System to verify compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The isotopic activity ratios of (135)Xe, (133m)Xe, (133)Xe and (131m)Xe are of interest for distinguishing nuclear explosion sources from civilian releases. Simulations of light water reactor (LWR) fuel burn-up through three operational reactor power cycles are conducted to explore the possible xenon isotopic signature of nuclear reactor releases under different operational conditions. It is studied how ratio changes are related to various parameters including the neutron flux, uranium enrichment and fuel burn-up. Further, the impact of diffusion and mixing on the isotopic activity ratio variability are explored. The simulations are validated with reported reactor emissions. In addition, activity ratios are calculated for xenon isotopes released from nuclear explosions and these are compared to the reactor ratios in order to determine whether the discrimination of explosion releases from reactor effluents is possible based on isotopic activity ratios.
Index of satisfaction in engineering courses in Portugal based on the students perspective
NASA Astrophysics Data System (ADS)
Oliveira, Raquel; Gonçalves, A. Manuela; Vasconcelos, Rosa M.
2016-06-01
In this work we describe and characterize the student's allocation satisfaction in the Portuguese public higher education system through the students' point of view, namely, in the academic engineering programs, extending previous studies of the author's team. We compare the ratio provided by the Portuguese Education Ministry through the Institutions' point of view, demand satisfaction index with the ratio proposed, applicant's satisfaction index, for the so called post-Bologna period. The data used in this paper covers the years from 2007 to 2013, provided by the Portuguese Education Institute. Mann-Whitney and Kruskal-Wallis tests were performed in order to assess whether there are significant differences between the ratios.
A Powerful Test for Comparing Multiple Regression Functions.
Maity, Arnab
2012-09-01
In this article, we address the important problem of comparison of two or more population regression functions. Recently, Pardo-Fernández, Van Keilegom and González-Manteiga (2007) developed test statistics for simple nonparametric regression models: Y(ij) = θ(j)(Z(ij)) + σ(j)(Z(ij))∊(ij), based on empirical distributions of the errors in each population j = 1, … , J. In this paper, we propose a test for equality of the θ(j)(·) based on the concept of generalized likelihood ratio type statistics. We also generalize our test for other nonparametric regression setups, e.g, nonparametric logistic regression, where the loglikelihood for population j is any general smooth function [Formula: see text]. We describe a resampling procedure to obtain the critical values of the test. In addition, we present a simulation study to evaluate the performance of the proposed test and compare our results to those in Pardo-Fernández et al. (2007).
New optical analyzer for 13C-breath test
NASA Astrophysics Data System (ADS)
Harde, Hermann; Dressler, Matthias; Helmrich, Günther; Wolff, Marcus; Groninga, Hinrich
2008-04-01
Medical breath tests are well established diagnostic tools, predominantly for gastroenterological inspections, but also for many other examinations. Since the composition and concentration of exhaled volatile gases reflect the physical condition of a patient, a breath analysis allows one to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that is based on photoacoustic spectroscopy and uses a DFB diode laser at 2.744 μm. The concentration ratio of the CO II isotopologues is determined by measuring the absorption on a 13CO II line in comparison to a 12CO II line. In the specially selected spectral range the lines have similar strengths, although the concentrations differ by a factor of 90. Therefore, the signals are well comparable. Due to an excellent signal-noise-ratio isotope variations of less than 1% can be resolved as required for the breath test.
Object-oriented classification of drumlins from digital elevation models
NASA Astrophysics Data System (ADS)
Saha, Kakoli
Drumlins are common elements of glaciated landscapes which are easily identified by their distinct morphometric characteristics including shape, length/width ratio, elongation ratio, and uniform direction. To date, most researchers have mapped drumlins by tracing contours on maps, or through on-screen digitization directly on top of hillshaded digital elevation models (DEMs). This paper seeks to utilize the unique morphometric characteristics of drumlins and investigates automated extraction of the landforms as objects from DEMs by Definiens Developer software (V.7), using the 30 m United States Geological Survey National Elevation Dataset DEM as input. The Chautauqua drumlin field in Pennsylvania and upstate New York, USA was chosen as a study area. As the study area is huge (approximately covers 2500 sq.km. of area), small test areas were selected for initial testing of the method. Individual polygons representing the drumlins were extracted from the elevation data set by automated recognition, using Definiens' Multiresolution Segmentation tool, followed by rule-based classification. Subsequently parameters such as length, width and length-width ratio, perimeter and area were measured automatically. To test the accuracy of the method, a second base map was produced by manual on-screen digitization of drumlins from topographic maps and the same morphometric parameters were extracted from the mapped landforms using Definiens Developer. Statistical comparison showed a high agreement between the two methods confirming that object-oriented classification for extraction of drumlins can be used for mapping these landforms. The proposed method represents an attempt to solve the problem by providing a generalized rule-set for mass extraction of drumlins. To check that the automated extraction process was next applied to a larger area. Results showed that the proposed method is as successful for the bigger area as it was for the smaller test areas.
Isotope ratio mass spectrometry in nutrition research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luke, A.H.
Many of the biochemical pathways and processes that form the foundation of modern nutrition research was elucidated using stable isotopes as physiological tracers. Since the discovery of stable isotopes, improvements and innovations in mass spectrometry and chromatography have led to greatly expanded applications. This research project was designed to evaluate gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) as a tool for isotopic tracer studies and to delineate the operational parameters for the analysis of {sup 13}C-labeled cholesterol, leucine and {alpha}-ketoisocaproate. The same isotope ratio mass spectrometer was then used as the base instrument for the ratio mass spectrometer was then usedmore » as the base instrument for the development of two additional inlet systems: a continuous-flow inlet for the analyses of {sup 13}C and {sup 18}O as CO{sub 2} and a filament inlet for on-line combustion and isotopic analysis of non-volatile organic compounds. Each of these three inlets was evaluated and their utility in nutrition research illustrated. GC/C/IRMS was used to analyze cholesterol, leucine and {alpha}-ketoisocaproate with good accuracy, precision and little isotopic memory. For all three compounds the detection limits achieved well surpassed currently used technologies. For compounds that can be well separated by GC, GC/C/IRMS is a valuable analytical tool. The continuous-flow inlet provided good accuracy and precision for measurements of {sup 13}CO{sub 2} from breath tests and {sup 18}O as CO{sub 2} from total energy expenditure tests. Most importantly, the continuous-flow inlet increased sample throughput by at least a factor of three over conventional analytical techniques. The filament inlet provided accurate and precise {sup 13}C ratio measurements of both natural abundance and enriched standards of non-volatile organic compounds of physiological interest.« less
Eissa, Maya S; Abou Al Alamein, Amal M
2018-03-15
Different innovative spectrophotometric methods were introduced for the first time for simultaneous quantification of sacubitril/valsartan in their binary mixture and in their combined dosage form without prior separation through two manipulation approaches. These approaches were developed and based either on two wavelength selection in zero-order absorption spectra namely; dual wavelength method (DWL) at 226nm and 275nm for valsartan, induced dual wavelength method (IDW) at 226nm and 254nm for sacubitril and advanced absorbance subtraction (AAS) based on their iso-absorptive point at 246nm (λ iso ) and 261nm (sacubitril shows equal absorbance values at the two selected wavelengths) or on ratio spectra using their normalized spectra namely; ratio difference spectrophotometric method (RD) at 225nm and 264nm for both of them in their ratio spectra, first derivative of ratio spectra (DR 1 ) at 232nm for valsartan and 239nm for sacubitril and mean centering of ratio spectra (MCR) at 260nm for both of them. Both sacubitril and valsartan showed linearity upon application of these methods in the range of 2.5-25.0μg/mL. The developed spectrophotmetric methods were successfully applied to the analysis of their combined tablet dosage form ENTRESTO™. The adopted spectrophotometric methods were also validated according to ICH guidelines. The results obtained from the proposed methods were statistically compared to a reported HPLC method using Student t-test, F-test and a comparative study was also developed with one-way ANOVA, showing no statistical difference in accordance to precision and accuracy. Copyright © 2017 Elsevier B.V. All rights reserved.
Pan, Qun-Xiong; Su, Zi-Jian; Zhang, Jian-Hua; Wang, Chong-Ren; Ke, Shao-Ying
2015-01-01
People's Republic of China is one of the countries with the highest incidence of gastric cancer, accounting for 45% of all new gastric cancer cases in the world. Therefore, strong prognostic markers are critical for the diagnosis and survival of Chinese patients suffering from gastric cancer. Recent studies have begun to unravel the mechanisms linking the host inflammatory response to tumor growth, invasion and metastasis in gastric cancers. Based on this relationship between inflammation and cancer progression, several inflammation-based scores have been demonstrated to have prognostic value in many types of malignant solid tumors. To compare the prognostic value of inflammation-based prognostic scores and tumor node metastasis (TNM) stage in patients undergoing gastric cancer resection. The inflammation-based prognostic scores were calculated for 207 patients with gastric cancer who underwent surgery. Glasgow prognostic score (GPS), neutrophil lymphocyte ratio (NLR), platelet lymphocyte ratio (PLR), prognostic nutritional index (PNI), and prognostic index (PI) were analyzed. Linear trend chi-square test, likelihood ratio chi-square test, and receiver operating characteristic were performed to compare the prognostic value of the selected scores and TNM stage. In univariate analysis, preoperative serum C-reactive protein (P<0.001), serum albumin (P<0.001), GPS (P<0.001), PLR (P=0.002), NLR (P<0.001), PI (P<0.001), PNI (P<0.001), and TNM stage (P<0.001) were significantly associated with both overall survival and disease-free survival of patients with gastric cancer. In multivariate analysis, GPS (P=0.024), NLR (P=0.012), PI (P=0.001), TNM stage (P<0.001), and degree of differentiation (P=0.002) were independent predictors of gastric cancer survival. GPS and TNM stage had a comparable prognostic value and higher linear trend chi-square value, likelihood ratio chi-square value, and larger area under the receiver operating characteristic curve as compared to other inflammation-based prognostic scores. The present study indicates that preoperative GPS and TNM stage are robust predictors of gastric cancer survival as compared to NLR, PLR, PI, and PNI in patients undergoing tumor resection.
Pan, Qun-Xiong; Su, Zi-Jian; Zhang, Jian-Hua; Wang, Chong-Ren; Ke, Shao-Ying
2015-01-01
Background People’s Republic of China is one of the countries with the highest incidence of gastric cancer, accounting for 45% of all new gastric cancer cases in the world. Therefore, strong prognostic markers are critical for the diagnosis and survival of Chinese patients suffering from gastric cancer. Recent studies have begun to unravel the mechanisms linking the host inflammatory response to tumor growth, invasion and metastasis in gastric cancers. Based on this relationship between inflammation and cancer progression, several inflammation-based scores have been demonstrated to have prognostic value in many types of malignant solid tumors. Objective To compare the prognostic value of inflammation-based prognostic scores and tumor node metastasis (TNM) stage in patients undergoing gastric cancer resection. Methods The inflammation-based prognostic scores were calculated for 207 patients with gastric cancer who underwent surgery. Glasgow prognostic score (GPS), neutrophil lymphocyte ratio (NLR), platelet lymphocyte ratio (PLR), prognostic nutritional index (PNI), and prognostic index (PI) were analyzed. Linear trend chi-square test, likelihood ratio chi-square test, and receiver operating characteristic were performed to compare the prognostic value of the selected scores and TNM stage. Results In univariate analysis, preoperative serum C-reactive protein (P<0.001), serum albumin (P<0.001), GPS (P<0.001), PLR (P=0.002), NLR (P<0.001), PI (P<0.001), PNI (P<0.001), and TNM stage (P<0.001) were significantly associated with both overall survival and disease-free survival of patients with gastric cancer. In multivariate analysis, GPS (P=0.024), NLR (P=0.012), PI (P=0.001), TNM stage (P<0.001), and degree of differentiation (P=0.002) were independent predictors of gastric cancer survival. GPS and TNM stage had a comparable prognostic value and higher linear trend chi-square value, likelihood ratio chi-square value, and larger area under the receiver operating characteristic curve as compared to other inflammation-based prognostic scores. Conclusion The present study indicates that preoperative GPS and TNM stage are robust predictors of gastric cancer survival as compared to NLR, PLR, PI, and PNI in patients undergoing tumor resection. PMID:26124667
Scattered light in a DMD based multi-object spectrometer
NASA Astrophysics Data System (ADS)
Fourspring, Kenneth D.; Ninkov, Zoran; Kerekes, John P.
2010-07-01
The DMD (Digital Micromirror Device) has an important future in both ground and space based multi-object spectrometers. A series of laboratory measurements have been performed to determine the scattered light properties of a DMD. The DMD under test had a 17 μm pitch and 1 μm gap between adjacent mirrors. Prior characterization of this device has focused on its use in DLP (TI Digital Light Processing) projector applications in which a whole pixel is illuminated by a uniform collimated source. The purpose of performing these measurements is to determine the limiting signal to noise ratio when utilizing the DMD as a slit mask in a spectrometer. The DMD pixel was determined to scatter more around the pixel edge and central via, indicating the importance of matching the telescope point spread function to the DMD. Also, the generation of DMD tested here was determined to have a significant mirror curvature. A maximum contrast ratio was determined at several wavelengths. Further measurements are underway on a newer generation DMD device, which has a smaller mirror pitch and likely different scatter characteristics. A previously constructed instrument, RITMOS (RIT Multi-Object Spectrometer) will be used to validate these scatter models and signal to noise ratio predications through imaging a star field.
NASA Astrophysics Data System (ADS)
Lu, Zheng; Chen, Xiaoyi; Zhou, Ying
2018-04-01
A particle tuned mass damper (PTMD) is a creative combination of a widely used tuned mass damper (TMD) and an efficient particle damper (PD) in the vibration control area. The performance of a one-storey steel frame attached with a PTMD is investigated through free vibration and shaking table tests. The influence of some key parameters (filling ratio of particles, auxiliary mass ratio, and particle density) on the vibration control effects is investigated, and it is shown that the attenuation level significantly depends on the filling ratio of particles. According to the experimental parametric study, some guidelines for optimization of the PTMD that mainly consider the filling ratio are proposed. Furthermore, an approximate analytical solution based on the concept of an equivalent single-particle damper is proposed, and it shows satisfied agreement between the simulation and experimental results. This simplified method is then used for the preliminary optimal design of a PTMD system, and a case study of a PTMD system attached to a five-storey steel structure following this optimization process is presented.
Supervised segmentation of microelectrode recording artifacts using power spectral density.
Bakstein, Eduard; Schneider, Jakub; Sieger, Tomas; Novak, Daniel; Wild, Jiri; Jech, Robert
2015-08-01
Appropriate detection of clean signal segments in extracellular microelectrode recordings (MER) is vital for maintaining high signal-to-noise ratio in MER studies. Existing alternatives to manual signal inspection are based on unsupervised change-point detection. We present a method of supervised MER artifact classification, based on power spectral density (PSD) and evaluate its performance on a database of 95 labelled MER signals. The proposed method yielded test-set accuracy of 90%, which was close to the accuracy of annotation (94%). The unsupervised methods achieved accuracy of about 77% on both training and testing data.
Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Pardo-Vazquez, Jose L; Leboran, Victor; Molenberghs, Geert; Faes, Christel; Acuña, Carlos
2011-06-30
It is well established that neural activity is stochastically modulated over time. Therefore, direct comparisons across experimental conditions and determination of change points or maximum firing rates are not straightforward. This study sought to compare temporal firing probability curves that may vary across groups defined by different experimental conditions. Odds-ratio (OR) curves were used as a measure of comparison, and the main goal was to provide a global test to detect significant differences of such curves through the study of their derivatives. An algorithm is proposed that enables ORs based on generalized additive models, including factor-by-curve-type interactions to be flexibly estimated. Bootstrap methods were used to draw inferences from the derivatives curves, and binning techniques were applied to speed up computation in the estimation and testing processes. A simulation study was conducted to assess the validity of these bootstrap-based tests. This methodology was applied to study premotor ventral cortex neural activity associated with decision-making. The proposed statistical procedures proved very useful in revealing the neural activity correlates of decision-making in a visual discrimination task. Copyright © 2011 John Wiley & Sons, Ltd.
Likelihood ratio-based integrated personal risk assessment of type 2 diabetes.
Sato, Noriko; Htun, Nay Chi; Daimon, Makoto; Tamiya, Gen; Kato, Takeo; Kubota, Isao; Ueno, Yoshiyuki; Yamashita, Hidetoshi; Fukao, Akira; Kayama, Takamasa; Muramatsu, Masaaki
2014-01-01
To facilitate personalized health care for multifactorial diseases, risks of genetic and clinical/environmental factors should be assessed together for each individual in an integrated fashion. This approach is possible with the likelihood ratio (LR)-based risk assessment system, as this system can incorporate manifold tests. We examined the usefulness of this system for assessing type 2 diabetes (T2D). Our system employed 29 genetic susceptibility variants, body mass index (BMI), and hypertension as risk factors whose LRs can be estimated from openly available T2D association data for the Japanese population. The pretest probability was set at a sex- and age-appropriate population average of diabetes prevalence. The classification performance of our LR-based risk assessment was compared to that of a non-invasive screening test for diabetes called TOPICS (with score based on age, sex, family history, smoking, BMI, and hypertension) using receiver operating characteristic analysis with a community cohort (n = 1263). The area under the receiver operating characteristic curve (AUC) for the LR-based assessment and TOPICS was 0.707 (95% CI 0.665-0.750) and 0.719 (0.675-0.762), respectively. These AUCs were much higher than that of a genetic risk score constructed using the same genetic susceptibility variants, 0.624 (0.574-0.674). The use of ethnically matched LRs is necessary for proper personal risk assessment. In conclusion, although LR-based integrated risk assessment for T2D still requires additional tests that evaluate other factors, such as risks involved in missing heritability, our results indicate the potential usability of LR-based assessment system and stress the importance of stratified epidemiological investigations in personalized medicine.
Tao, Jinyuan; Gunter, Glenda; Tsai, Ming-Hsiu; Lim, Dan
2016-01-01
Recently, the many robust learning management systems, and the availability of affordable laptops, have made secure laptop-based testing a reality on many campuses. The undergraduate nursing program at the authors' university began to implement a secure laptop-based testing program in 2009, which allowed students to use their newly purchased laptops to take quizzes and tests securely in classrooms. After nearly 5 years' secure laptop-based testing program implementation, a formative evaluation, using a mixed method that has both descriptive and correlational data elements, was conducted to seek constructive feedback from students to improve the program. Evaluation data show that, overall, students (n = 166) believed the secure laptop-based testing program helps them get hands-on experience of taking examinations on the computer and gets them prepared for their computerized NCLEX-RN. Students, however, had a lot of concerns about laptop glitches and campus wireless network glitches they experienced during testing. At the same time, NCLEX-RN first-time passing rate data were analyzed using the χ2 test, and revealed no significant association between the two testing methods (paper-and-pencil testing and the secure laptop-based testing) and students' first-time NCLEX-RN passing rate. Based on the odds ratio, however, the odds of students passing NCLEX-RN the first time was 1.37 times higher if they were taught with the secure laptop-based testing method than if taught with the traditional paper-and-pencil testing method in nursing school. It was recommended to the institution that better quality of laptops needs to be provided to future students, measures needed to be taken to further stabilize the campus wireless Internet network, and there was a need to reevaluate the Laptop Initiative Program.
Wolff, Antonio C; Hammond, M Elizabeth Hale; Allison, Kimberly H; Harvey, Brittany E; Mangu, Pamela B; Bartlett, John M S; Bilous, Michael; Ellis, Ian O; Fitzgibbons, Patrick; Hanna, Wedad; Jenkins, Robert B; Press, Michael F; Spears, Patricia A; Vance, Gail H; Viale, Giuseppe; McShane, Lisa M; Dowsett, Mitchell
2018-05-30
Purpose To update key recommendations of the American Society of Clinical Oncology/College of American Pathologists human epidermal growth factor receptor 2 (HER2) testing in breast cancer guideline. Methods Based on the signals approach, an Expert Panel reviewed published literature and research survey results on the observed frequency of less common in situ hybridization (ISH) patterns to update the recommendations. Recommendations Two recommendations addressed via correspondence in 2015 are included. First, immunohistochemistry (IHC) 2+ is defined as invasive breast cancer with weak to moderate complete membrane staining observed in > 10% of tumor cells. Second, if the initial HER2 test result in a core needle biopsy specimen of a primary breast cancer is negative, a new HER2 test may (not "must") be ordered on the excision specimen based on specific clinical criteria. The HER2 testing algorithm for breast cancer is updated to address the recommended work-up for less common clinical scenarios (approximately 5% of cases) observed when using a dual-probe ISH assay. These scenarios are described as ISH group 2 ( HER2/chromosome enumeration probe 17 [CEP17] ratio ≥ 2.0; average HER2 copy number < 4.0 signals per cell), ISH group 3 ( HER2/CEP17 ratio < 2.0; average HER2 copy number ≥ 6.0 signals per cell), and ISH group 4 ( HER2/CEP17 ratio < 2.0; average HER2 copy number ≥ 4.0 and < 6.0 signals per cell). The diagnostic approach includes more rigorous interpretation criteria for ISH and requires concomitant IHC review for dual-probe ISH groups 2 to 4 to arrive at the most accurate HER2 status designation (positive or negative) based on combined interpretation of the ISH and IHC assays. The Expert Panel recommends that laboratories using single-probe ISH assays include concomitant IHC review as part of the interpretation of all single-probe ISH assay results. Find additional information at www.asco.org/breast-cancer-guidelines .
Morphology parameters for intracranial aneurysm rupture risk assessment.
Dhar, Sujan; Tremmel, Markus; Mocco, J; Kim, Minsuok; Yamamoto, Junichi; Siddiqui, Adnan H; Hopkins, L Nelson; Meng, Hui
2008-08-01
The aim of this study is to identify image-based morphological parameters that correlate with human intracranial aneurysm (IA) rupture. For 45 patients with terminal or sidewall saccular IAs (25 unruptured, 20 ruptured), three-dimensional geometries were evaluated for a range of morphological parameters. In addition to five previously studied parameters (aspect ratio, aneurysm size, ellipticity index, nonsphericity index, and undulation index), we defined three novel parameters incorporating the parent vessel geometry (vessel angle, aneurysm [inclination] angle, and [aneurysm-to-vessel] size ratio) and explored their correlation with aneurysm rupture. Parameters were analyzed with a two-tailed independent Student's t test for significance; significant parameters (P < 0.05) were further examined by multivariate logistic regression analysis. Additionally, receiver operating characteristic analyses were performed on each parameter. Statistically significant differences were found between mean values in ruptured and unruptured groups for size ratio, undulation index, nonsphericity index, ellipticity index, aneurysm angle, and aspect ratio. Logistic regression analysis further revealed that size ratio (odds ratio, 1.41; 95% confidence interval, 1.03-1.92) and undulation index (odds ratio, 1.51; 95% confidence interval, 1.08-2.11) had the strongest independent correlation with ruptured IA. From the receiver operating characteristic analysis, size ratio and aneurysm angle had the highest area under the curve values of 0.83 and 0.85, respectively. Size ratio and aneurysm angle are promising new morphological metrics for IA rupture risk assessment. Because these parameters account for vessel geometry, they may bridge the gap between morphological studies and more qualitative location-based studies.
NASA Technical Reports Server (NTRS)
Mader, G. L.
1981-01-01
A technique for producing topographic information is described which is based on same side/same time viewing using a dissimilar combination of radar imagery and photographic images. Common geographic areas viewed from similar space reference locations produce scene elevation displacements in opposite direction and proper use of this characteristic can yield the perspective information necessary for determination of base to height ratios. These base to height ratios can in turn be used to produce a topographic map. A test area covering the Harrisburg, Pennsylvania region was observed by synthetic aperture radar on the Seasat satellite and by return beam vidicon on by the LANDSAT - 3 satellite. The techniques developed for the scaling re-orientation and common registration of the two images are presented along with the topographic determination data. Topographic determination based exclusively on the images content is compared to the map information which is used as a performance calibration base.
Krill, Michael K; Rosas, Samuel; Kwon, KiHyun; Dakkak, Andrew; Nwachukwu, Benedict U; McCormick, Frank
2018-02-01
The clinical examination of the shoulder joint is an undervalued diagnostic tool for evaluating acromioclavicular (AC) joint pathology. Applying evidence-based clinical tests enables providers to make an accurate diagnosis and minimize costly imaging procedures and potential delays in care. The purpose of this study was to create a decision tree analysis enabling simple and accurate diagnosis of AC joint pathology. A systematic review of the Medline, Ovid and Cochrane Review databases was performed to identify level one and two diagnostic studies evaluating clinical tests for AC joint pathology. Individual test characteristics were combined in series and in parallel to improve sensitivities and specificities. A secondary analysis utilized subjective pre-test probabilities to create a clinical decision tree algorithm with post-test probabilities. The optimal special test combination to screen and confirm AC joint pathology combined Paxinos sign and O'Brien's Test, with a specificity of 95.8% when performed in series; whereas, Paxinos sign and Hawkins-Kennedy Test demonstrated a sensitivity of 93.7% when performed in parallel. Paxinos sign and O'Brien's Test demonstrated the greatest positive likelihood ratio (2.71); whereas, Paxinos sign and Hawkins-Kennedy Test reported the lowest negative likelihood ratio (0.35). No combination of special tests performed in series or in parallel creates more than a small impact on post-test probabilities to screen or confirm AC joint pathology. Paxinos sign and O'Brien's Test is the only special test combination that has a small and sometimes important impact when used both in series and in parallel. Physical examination testing is not beneficial for diagnosis of AC joint pathology when pretest probability is unequivocal. In these instances, it is of benefit to proceed with procedural tests to evaluate AC joint pathology. Ultrasound-guided corticosteroid injections are diagnostic and therapeutic. An ultrasound-guided AC joint corticosteroid injection may be an appropriate new standard for treatment and surgical decision-making. II - Systematic Review.
D-OPTIMAL EXPERIMENTAL DESIGNS TO TEST FOR DEPARTURE FROM ADDITIVITY IN A FIXED-RATIO MIXTURE RAY.
Traditional factorial designs for evaluating interactions among chemicals in a mixture are prohibitive when the number of chemicals is large. However, recent advances in statistically-based experimental design have made it easier to evaluate interactions involving many chemicals...
NGS-based likelihood ratio for identifying contributors in two- and three-person DNA mixtures.
Chan Mun Wei, Joshua; Zhao, Zicheng; Li, Shuai Cheng; Ng, Yen Kaow
2018-06-01
DNA fingerprinting, also known as DNA profiling, serves as a standard procedure in forensics to identify a person by the short tandem repeat (STR) loci in their DNA. By comparing the STR loci between DNA samples, practitioners can calculate a probability of match to identity the contributors of a DNA mixture. Most existing methods are based on 13 core STR loci which were identified by the Federal Bureau of Investigation (FBI). Analyses based on these loci of DNA mixture for forensic purposes are highly variable in procedures, and suffer from subjectivity as well as bias in complex mixture interpretation. With the emergence of next-generation sequencing (NGS) technologies, the sequencing of billions of DNA molecules can be parallelized, thus greatly increasing throughput and reducing the associated costs. This allows the creation of new techniques that incorporate more loci to enable complex mixture interpretation. In this paper, we propose a computation for likelihood ratio that uses NGS (next generation sequencing) data for DNA testing on mixed samples. We have applied the method to 4480 simulated DNA mixtures, which consist of various mixture proportions of 8 unrelated whole-genome sequencing data. The results confirm the feasibility of utilizing NGS data in DNA mixture interpretations. We observed an average likelihood ratio as high as 285,978 for two-person mixtures. Using our method, all 224 identity tests for two-person mixtures and three-person mixtures were correctly identified. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bingemann, Dieter; Allen, Rachel M.
2012-01-01
We describe a statistical method to analyze dual-channel photon arrival trajectories from single molecule spectroscopy model-free to identify break points in the intensity ratio. Photons are binned with a short bin size to calculate the logarithm of the intensity ratio for each bin. Stochastic photon counting noise leads to a near-normal distribution of this logarithm and the standard student t-test is used to find statistically significant changes in this quantity. In stochastic simulations we determine the significance threshold for the t-test’s p-value at a given level of confidence. We test the method’s sensitivity and accuracy indicating that the analysis reliably locates break points with significant changes in the intensity ratio with little or no error in realistic trajectories with large numbers of small change points, while still identifying a large fraction of the frequent break points with small intensity changes. Based on these results we present an approach to estimate confidence intervals for the identified break point locations and recommend a bin size to choose for the analysis. The method proves powerful and reliable in the analysis of simulated and actual data of single molecule reorientation in a glassy matrix. PMID:22837704
Packiriswamy, Vasanthakumar; Kumar, Pramod; Rao, Mohandas
2012-12-01
The "golden ratio" is considered as a universal facial aesthetical standard. Researcher's opinion that deviation from golden ratio can result in development of facial abnormalities. This study was designed to study the facial morphology and to identify individuals with normal, short, and long face. We studied 300 Malaysian nationality subjects aged 18-28 years of Chinese, Indian, and Malay extraction. The parameters measured were physiognomical facial height and width of face, and physiognomical facial index was calculated. Face shape was classified based on golden ratio. Independent t test was done to test the difference between sexes and among the races. The mean values of the measurements and index showed significant sexual and interracial differences. Out of 300 subjects, the face shape was normal in 60 subjects, short in 224 subjects, and long in 16 subjects. As anticipated, the measurements showed variations according to gender and race. Only 60 subjects had a regular face shape, and remaining 240 subjects had irregular face shape (short and long). Since the short and long shape individuals may be at risk of developing various disorders, the knowledge of facial shapes in the given population is important for early diagnostic and treatment procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Kyungsang; Ye, Jong Chul, E-mail: jong.ye@kaist.ac.kr; Lee, Taewon
2015-09-15
Purpose: In digital breast tomosynthesis (DBT), scatter correction is highly desirable, as it improves image quality at low doses. Because the DBT detector panel is typically stationary during the source rotation, antiscatter grids are not generally compatible with DBT; thus, a software-based scatter correction is required. This work proposes a fully iterative scatter correction method that uses a novel fast Monte Carlo simulation (MCS) with a tissue-composition ratio estimation technique for DBT imaging. Methods: To apply MCS to scatter estimation, the material composition in each voxel should be known. To overcome the lack of prior accurate knowledge of tissue compositionmore » for DBT, a tissue-composition ratio is estimated based on the observation that the breast tissues are principally composed of adipose and glandular tissues. Using this approximation, the composition ratio can be estimated from the reconstructed attenuation coefficients, and the scatter distribution can then be estimated by MCS using the composition ratio. The scatter estimation and image reconstruction procedures can be performed iteratively until an acceptable accuracy is achieved. For practical use, (i) the authors have implemented a fast MCS using a graphics processing unit (GPU), (ii) the MCS is simplified to transport only x-rays in the energy range of 10–50 keV, modeling Rayleigh and Compton scattering and the photoelectric effect using the tissue-composition ratio of adipose and glandular tissues, and (iii) downsampling is used because the scatter distribution varies rather smoothly. Results: The authors have demonstrated that the proposed method can accurately estimate the scatter distribution, and that the contrast-to-noise ratio of the final reconstructed image is significantly improved. The authors validated the performance of the MCS by changing the tissue thickness, composition ratio, and x-ray energy. The authors confirmed that the tissue-composition ratio estimation was quite accurate under a variety of conditions. Our GPU-based fast MCS implementation took approximately 3 s to generate each angular projection for a 6 cm thick breast, which is believed to make this process acceptable for clinical applications. In addition, the clinical preferences of three radiologists were evaluated; the preference for the proposed method compared to the preference for the convolution-based method was statistically meaningful (p < 0.05, McNemar test). Conclusions: The proposed fully iterative scatter correction method and the GPU-based fast MCS using tissue-composition ratio estimation successfully improved the image quality within a reasonable computational time, which may potentially increase the clinical utility of DBT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adur, A.M.
Three species of bamboo were converted to bamboo-polymer composites by vacuum impregnation with monomer and in situ polymerization using gamma irradiation. Resistance of the composites to various chemicals present in concrete was tested. Resistance to termites, fungus and other forms of biological attack was examined. Strength-to-weight ratios were calculated based on mechanical tests performed earlier (paper II of this three-part series). Possible application for tensile reinforcement of concrete is discussed in considerable detail. 2 figures, 4 tables.
Performance deterioration of commercial high-bypass ratio turbofan engines
NASA Technical Reports Server (NTRS)
Mehalic, C. M.; Ziemianski, J. A.
1980-01-01
The results of engine performance deterioration investigations based on historical data, special engine tests, and specific tests to define the influence of flight loads and component clearances on performance are presented. The results of analyses of several damage mechanisms that contribute to performance deterioration such as blade tip rubs, airfoil surface roughness and erosion, and thermal distortion are also included. The significance of these damage mechanisms on component and overall engine performance is discussed.
NASA Astrophysics Data System (ADS)
Glazkov, S. A.; Gorbushin, A. R.; Osipova, S. L.; Semenov, A. V.
2016-10-01
The report describes the results of flow field experimental research in TsAGI T-128 transonic wind tunnel. During the tests Mach number, stagnation pressure, test section wall perforation ratio, angles between the test section panels and mixing chamber flaps varied. Based on the test results one determined corrections to the free-stream Mach number related to the flow speed difference in the model location and in the zone of static pressure measurement on the test section walls, nonuniformity of the longitudinal velocity component in the model location, optimal position of the movable test section elements to provide flow field uniformity in the test section and minimize the test leg drag.
Significance of parametric spectral ratio methods in detection and recognition of whispered speech
NASA Astrophysics Data System (ADS)
Mathur, Arpit; Reddy, Shankar M.; Hegde, Rajesh M.
2012-12-01
In this article the significance of a new parametric spectral ratio method that can be used to detect whispered speech segments within normally phonated speech is described. Adaptation methods based on the maximum likelihood linear regression (MLLR) are then used to realize a mismatched train-test style speech recognition system. This proposed parametric spectral ratio method computes a ratio spectrum of the linear prediction (LP) and the minimum variance distortion-less response (MVDR) methods. The smoothed ratio spectrum is then used to detect whispered segments of speech within neutral speech segments effectively. The proposed LP-MVDR ratio method exhibits robustness at different SNRs as indicated by the whisper diarization experiments conducted on the CHAINS and the cell phone whispered speech corpus. The proposed method also performs reasonably better than the conventional methods for whisper detection. In order to integrate the proposed whisper detection method into a conventional speech recognition engine with minimal changes, adaptation methods based on the MLLR are used herein. The hidden Markov models corresponding to neutral mode speech are adapted to the whispered mode speech data in the whispered regions as detected by the proposed ratio method. The performance of this method is first evaluated on whispered speech data from the CHAINS corpus. The second set of experiments are conducted on the cell phone corpus of whispered speech. This corpus is collected using a set up that is used commercially for handling public transactions. The proposed whisper speech recognition system exhibits reasonably better performance when compared to several conventional methods. The results shown indicate the possibility of a whispered speech recognition system for cell phone based transactions.
Xu, Jing-jing; Xu, Dan; Huang, Tao; Jiang, Jian; Lü, Fan
2012-05-01
To detect the accommodative convergence to accommodation (AC/A) ratios measured respectively by objective and subjective methods. The differences and its relative factors were explored. Forty young volunteers were measured by eye tracker to get the amount of convergence when fixating at the target at 100 cm, 50 cm, 33 cm and 25 cm and were measured by infrared auto-refractor to get corresponding accommodative responses. AC/A ratio based on these two measurements were compared with the calculated and the gradient AC/A ratio from Von Graefe tests. Mean value of stimulated AC/A ratio measured by eye tracker was higher than the calculated and gradient AC/A ratio by Von Graefe method (P = 0.003, 0.001). There are statistic correlation (r = 0.871, P = 0.000) and difference (P = 0.000) between stimulated AC/A ratio and response AC/A ratios both measured by eye tracker, and the difference trends to be greater with the higher AC/A ratio. The objective AC/A ratio is usually higher than the clinical subjective measurement because of more proximal effect. The response AC/A ratio measured objectively may reveal realistically the mutual effect and relationship between accommodation and convergence and it seems to be more credible to be the monitor parameter on progression of myopia in clinics.
Sea level side loads in high-area-ratio rocket engines
NASA Technical Reports Server (NTRS)
Nave, L. H.; Coffey, G. A.
1973-01-01
An empirical separation and side load model to obtain applied aerodynamic loads has been developed based on data obtained from full-scale J-2S (265K-pound-thrust engine with an area ratio of 40:1) engine and model testing. Experimental data include visual observations of the separation patterns that show the dynamic nature of the separation phenomenon. Comparisons between measured and applied side loads are made. Correlations relating the separation location to the applied side loads and the methods used to determine the separation location are given.
The fatigue behavior of composite laminates under various mean stresses
NASA Technical Reports Server (NTRS)
Rotem, A.
1991-01-01
A method is developed for predicting the S-N curve of a composite laminate which is subjected to an arbitrary stress ratio, R (minimum stress/maximum stress). The method is based on the measuring of the S-N behavior of two distinct cases, tension-tension and compression-compression fatigue loadings. Using these parameters, expressions are formulated that estimate the fatigue behavior under any stress ratio loading. Experimental results from the testing of graphite/epoxy laminates, with various structures, are compared with the predictions and show good agreement.
NASA Astrophysics Data System (ADS)
Magdy, Nancy; Ayad, Miriam F.
2015-02-01
Two simple, accurate, precise, sensitive and economic spectrophotometric methods were developed for the simultaneous determination of Simvastatin and Ezetimibe in fixed dose combination products without prior separation. The first method depends on a new chemometrics-assisted ratio spectra derivative method using moving window polynomial least square fitting method (Savitzky-Golay filters). The second method is based on a simple modification for the ratio subtraction method. The suggested methods were validated according to USP guidelines and can be applied for routine quality control testing.
Heat Transfer in Conical Corner and Short Superelliptical Transition Ducts
NASA Technical Reports Server (NTRS)
Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven
2008-01-01
Local surface heat transfer measurements were experimentally mapped using a transient liquid-crystal heat-transfer technique on the surface of two circular-to-rectangular transition ducts. One has a transition cross section defined by conical corners (Duct 1) and the other by an elliptical equation with changing coefficients (Duct 2). Duct 1 has a length-to-diameter ratio of 0.75 and an exit plane aspect ratio of 1.5. Duct 2 has a length-to-diameter ratio of 1.0 and an exit plane aspect ratio of 2.9. Test results are reported for various inlet-diameter-based Reynolds numbers ranging from 0.45 106 to 2.39 106 and two freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.
Pre-Test Assessment of the Use Envelope of the Normal Force of a Wind Tunnel Strain-Gage Balance
NASA Technical Reports Server (NTRS)
Ulbrich, N.
2016-01-01
The relationship between the aerodynamic lift force generated by a wind tunnel model, the model weight, and the measured normal force of a strain-gage balance is investigated to better understand the expected use envelope of the normal force during a wind tunnel test. First, the fundamental relationship between normal force, model weight, lift curve slope, model reference area, dynamic pressure, and angle of attack is derived. Then, based on this fundamental relationship, the use envelope of a balance is examined for four typical wind tunnel test cases. The first case looks at the use envelope of the normal force during the test of a light wind tunnel model at high subsonic Mach numbers. The second case examines the use envelope of the normal force during the test of a heavy wind tunnel model in an atmospheric low-speed facility. The third case reviews the use envelope of the normal force during the test of a floor-mounted semi-span model. The fourth case discusses the normal force characteristics during the test of a rotated full-span model. The wind tunnel model's lift-to-weight ratio is introduced as a new parameter that may be used for a quick pre-test assessment of the use envelope of the normal force of a balance. The parameter is derived as a function of the lift coefficient, the dimensionless dynamic pressure, and the dimensionless model weight. Lower and upper bounds of the use envelope of a balance are defined using the model's lift-to-weight ratio. Finally, data from a pressurized wind tunnel is used to illustrate both application and interpretation of the model's lift-to-weight ratio.
NASA Astrophysics Data System (ADS)
Kim, Y. H.; Kim, D. G.; Sung, J. H.; Kim, I. S.; Ko, D. E.; Kang, N. H.; Hong, H. U.; Park, J. H.; Lee, H. W.
2011-02-01
To study the pitting corrosion of AISI 316L weld metals according to the chromium/nickel equivalent ratio (Creq/Nieq ratio), three filler wires were newly designed for the flux-cored arc welding process. The weld metal with delta-ferrite at less than 3 vol.%, was observed for ductility-dip cracking (DDC) in the reheated region after multi-pass welding. The tensile strength and yield strength increased with increasing Creq/Nieq ratio. The result of anodic polarization tests in a 0.1 M NaCl solution at the room temperature (25) for 45 min, revealed that the base metal and weld metals have a similar corrosion potential of -0.34 VSCE. The weld metal with the highest content of Cr had the highest pitting potential (0.39 VSCE) and the passivation range (0.64 VSCE) was higher than the base metal (0.21 VSCE and 0.46 VSCE, respectively). Adding 0.001 M Na2S to the 0.1M NaCl solution, the corrosion occurred more severely by H2S. The corrosion potentials of the base metal and three weld metals decreased to -1.0 VSCE. DDC caused the decrease of the pitting potential by inducing a locally intense corrosion attack around the crack openings.
Combining matched and unmatched control groups in case-control studies.
le Cessie, Saskia; Nagelkerke, Nico; Rosendaal, Frits R; van Stralen, Karlijn J; Pomp, Elisabeth R; van Houwelingen, Hans C
2008-11-15
Multiple control groups in case-control studies are used to control for different sources of confounding. For example, cases can be contrasted with matched controls to adjust for multiple genetic or unknown lifestyle factors and simultaneously contrasted with an unmatched population-based control group. Inclusion of different control groups for a single exposure analysis yields several estimates of the odds ratio, all using only part of the data. Here the authors introduce an easy way to combine odds ratios from several case-control analyses with the same cases. The approach is based upon methods used for meta-analysis but takes into account the fact that the same cases are used and that the estimated odds ratios are therefore correlated. Two ways of estimating this correlation are discussed: sandwich methodology and the bootstrap. Confidence intervals for the pooled estimates and a test for checking whether the odds ratios in the separate case-control studies differ significantly are derived. The performance of the method is studied by simulation and by applying the methods to a large study on risk factors for thrombosis, the MEGA Study (1999-2004), wherein cases with first venous thrombosis were included with a matched control group of partners and an unmatched population-based control group.
A more powerful exact test of noninferiority from binary matched-pairs data.
Lloyd, Chris J; Moldovan, Max V
2008-08-15
Assessing the therapeutic noninferiority of one medical treatment compared with another is often based on the difference in response rates from a matched binary pairs design. This paper develops a new exact unconditional test for noninferiority that is more powerful than available alternatives. There are two new elements presented in this paper. First, we introduce the likelihood ratio statistic as an alternative to the previously proposed score statistic of Nam (Biometrics 1997; 53:1422-1430). Second, we eliminate the nuisance parameter by estimation followed by maximization as an alternative to the partial maximization of Berger and Boos (Am. Stat. Assoc. 1994; 89:1012-1016) or traditional full maximization. Based on an extensive numerical study, we recommend tests based on the score statistic, the nuisance parameter being controlled by estimation followed by maximization. 2008 John Wiley & Sons, Ltd
Shear Wave Velocity for Evaluation of State of Cohesionless Soils with Fines
NASA Astrophysics Data System (ADS)
Lipiński, Mirosław J.; Wdowska, Małgorzata K.; Jaroń, Łukasz
2017-10-01
The paper concerns evaluation of cohesionless soils containing fines. In clean sands, state of soil is usually quantified by relative density DR with use of field techniques like static or dynamic probes. However, in cohesionless soils containing considerable amount of fines, relative density alone, which is based solely on void ratio values, is not representative. This results from the fact that in case of cohesionless soil there is no unique intrinsic compressibility line, like it is in case of cohesive soils. Thus state of soil depends not only on void ratio but also state of stress. For this reason it is necessary to look for an alternative means to quantify state of soils with fines. The paper concerns possibility of evaluation of state of soil containing various amount of fines on the basis of shear wave velocity measurement. The idea rests on the fact that void ratio and state of stress are the major factors which contribute to a state of soil and shear wave velocity as well. When measured shear wave velocities are normalised with respect to stresses the resulting values might be strictly correlated to void ratio. To validate this approach, an experimental test programme (based on series of sophisticated triaxial tests) was carried out on four kinds of sandy material containing various amount of fines up to 60%. The experimental data made possible to establish basic correlation between soil states and shear wave velocity for each kind of soil. Normalized shear wave velocity was compared with void ratio and state parameter as well. The obtained results revealed that determination of void ratio on the basis of shear wave velocity in a certain range of fines can be much more adequate than for clean sands. However, if the fines content exceeds certain value, the obtained correlation is no longer as good.
A GREAT search for Deuterium in Comets
NASA Astrophysics Data System (ADS)
Mumma, Michael
2012-10-01
Comets are understood to be the most pristine bodies in the Solar System. Their compositions reflect the chemical state of materials at the very earliest evolutionary stages of the protosolar nebula and, as such, they provide detailed insight into the physical and chemical processes operating in planet-forming disks. Isotopic fractionation ratios of the molecular ices in the nucleus are regarded as signatures of formation processes. These ratios provide unique information on the natal heritage of those ices, and can also test the proposal that Earth's water and other volatiles were delivered by cometary bombardment. Measurement of deuterium fractionation ratios is thus a major goal in contemporary cometary science and the D/H ratio of water - the dominant volatile in comets - holds great promise for testing the formation history of cometary matter. The D/H ratio in cometary water has been measured in only seven comets. Six were from the Oort Cloud reservoir and the D/H ratio was about twice that of the Earth's oceans. However, the recent Herschel measurement of HDO/H2O in 103P/Hartley-2 (the first from the Kuiper Belt) was consistent with exogenous delivery of Earth's water by comets. Outstanding questions remain: are cometary HDO/H2O ratios consistent with current theories of nebular chemical evolution or with an interstellar origin? Does the HDO/H2O ratio vary substantially among comet populations? Hartley-2 is the only Kuiper Belt comet with measured HDO/H2O, are there comets with similar ratios in the Oort cloud? These questions can only be addressed by measuring HDO/H2O ratios in many more suitable bright comets. We therefore propose to measure the D/H ratio in water in a suitable target-of-opportunity comet by performing observations of HDO and OH with the GREAT spectrometer on SOFIA. A multi-wavelength, ground-based observing campaign will also be conducted in support of the airborne observations.
A GREAT search for Deuterium in Comets
NASA Astrophysics Data System (ADS)
Mumma, Michael
2013-10-01
Comets are understood to be the most pristine bodies in the Solar System. Their compositions reflect the chemical state of materials at the very earliest evolutionary stages of the protosolar nebula and, as such, they provide detailed insight into the physical and chemical processes operating in planet-forming disks. Isotopic fractionation ratios of the molecular ices in the nucleus are regarded as signatures of formation processes. These ratios provide unique information on the natal heritage of those ices, and can also test the proposal that Earth's water and other volatiles were delivered by cometary bombardment. Measurement of deuterium fractionation ratios is thus a major goal in contemporary cometary science and the D/H ratio of water - the dominant volatile in comets - holds great promise for testing the formation history of cometary matter. The D/H ratio in cometary water has been measured in only eight comets. Seven were from the Oort Cloud reservoir and the D/H ratio was about twice that of the Earth's oceans. However, the recent Herschel measurement of HDO/H2O in 103P/Hartley-2 (the first from the Kuiper Belt) was consistent with exogenous delivery of Earth's water by comets. Outstanding questions remain: are cometary HDO/H2O ratios consistent with current theories of nebular chemical evolution or with an interstellar origin? Does the HDO/H2O ratio vary substantially among comet populations? Hartley-2 is the only Kuiper Belt comet with measured HDO/H2O, are there comets with similar ratios in the Oort cloud? These questions can only be addressed by measuring HDO/H2O ratios in many more suitable bright comets. We therefore propose to measure the D/H ratio in water in a suitable target-of-opportunity comet by performing observations of HDO and OH with the GREAT spectrometer on SOFIA. A multi-wavelength, ground-based observing campaign will also be conducted in support of the airborne observations.
Aeroelastic considerations for torsionally soft rotors
NASA Technical Reports Server (NTRS)
Mantay, W. R.; Yeager, W. T., Jr.
1985-01-01
A research study was initiated to systematically determine the impact of selected blade tip geometric parameters on conformable rotor performance and loads characteristics. The model articulated rotors included baseline and torsionally soft blades with interchangeable tips. Seven blade tip designs were evaluated on the baseline rotor and six tip designs were tested on the torsionally soft blades. The designs incorporated a systemmatic variation in geometric parameters including sweep, taper, and anhedral. The rotors were evaluated in the NASA Langley Transonic Dynamics Tunnel at several advance ratios, lift and propulsive force values, and tip Mach numbers. A track sensitivity study was also conducted at several advance ratios for both rotors. Based on the test results, tip parameter variations generated significant rotor performance and loads differences for both baseline and torsionally soft blades.
1994-03-01
labels of a, which is called significance levels. The hypothesis tests are done based on the a levels . The maximum probabilities of making type II error...critical values at specific a levels . This procedure is done for each of the 50,000 samples. The number of the samples passing each test at those specific... a levels is counted. The ratio of the number of accepted samples to 50,000 gives the percentage point. Then, subtracting that value from one would
The Column Strength of Two Extruded Aluminum-Alloy H-Sections
NASA Technical Reports Server (NTRS)
Osgood, William R; Holt, Marshall
1939-01-01
Extruded aluminum-alloy members of various cross sections are used in aircraft as compression members either singly or as stiffeners for aluminum-alloy sheet. In order to design such members, it is necessary to know their column strength or, in the case of stiffeners, the value of the double modulus, which is best obtained for practical purposes from column tests. Column tests made on two extruded h-sections are described, and column formulas and formulas for the ratio of the double modulus to Young's modulus, based on the tests, are given.
NASA Technical Reports Server (NTRS)
Mennell, R. C.
1974-01-01
Tests were conducted to investigate various base drag reduction techniques in an attempt to improve Orbiter lift-to-drag ratios and to calculate sting interference effects on the Orbiter aerodynamic characteristics. Test conditions and facilites, and model dimensional data are presented along with the data reduction guidelines and data set/run number collation used for the studies. Aerodynamic force and moment data and the results of stability and control tests are also given.
Crack Branching and Fracture Mirror Data of Glasses and Advanced Ceramics
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Gyekenyesi, John P.
1998-01-01
The fracture mirror and crack branching constants were determined from three glasses and nine advanced ceramics tested under various loading and specimen configurations in an attempt to use the constants as a data base for fractography. The ratios of fracture mirror or crack branching constant to fracture toughness were found to be approximately two for most ceramic materials tested. A demonstration of how to use the two constants as a tool for verifying stress measurements was presented for silicon nitride disk specimens subjected to high-temperature, constant stress-rate biaxial flexure testing.
Scholz, Stefan; Schreiber, Rene; Armitage, James; Mayer, Philipp; Escher, Beate I; Lidzba, Annegret; Léonard, Marc; Altenburger, Rolf
2018-04-01
Fish early life stage (ELS) tests (Organisation for Economic Co-operation and Development test guideline 210) are widely conducted to estimate chronic fish toxicity. In these tests, fish are exposed from the embryonic to the juvenile life stages. To analyze whether certain modes of action are related to high toxic ratios (i.e., ratios between baseline toxicity and experimental effect) and/or acute-to-chronic ratios (ACRs) in the fish ELS test, effect concentrations (ECs) for 183 compounds were extracted from the US Environmental Protection Agency's ecotoxicity database. Analysis of ECs of narcotic compounds indicated that baseline toxicity could be observed in the fish ELS test at similar concentrations as in the acute fish toxicity test. All nonnarcotic modes of action were associated with higher toxic ratios, with median values ranging from 4 to 9.3 × 10 4 (uncoupling < reactivity < neuromuscular toxicity < methemoglobin formation < endocrine disruption < extracellular matrix formation inhibition). Four modes of action were also found to be associated with high ACRs: 1) lysyl oxidase inhibition leading to notochord distortion, 2) putative methemoglobin formation or hemolytic anemia, 3) endocrine disruption, and 4) compounds with neuromuscular toxicity. For the prediction of ECs in the fish ELS test with alternative test systems, endpoints targeted to the modes of action of compounds with enhanced toxic ratios or ACRs could be used to trigger fish ELS tests or even replace these tests. Environ Toxicol Chem 2018;37:955-969. © 2018 SETAC. © 2018 SETAC.
Optimization of Orifice Geometry for Cross-Flow Mixing in a Cylindrical Duct
NASA Technical Reports Server (NTRS)
Sowa, W. A.; Kroll, J. T.; Samuelsen, G. S.; Holdeman, J. D.
1994-01-01
Mixing of gaseous jets in a cross-flow has significant applications in engineering, one example of which is the dilution zone of a gas turbine combustor. Despite years of study, the design of jet injection in combustors is largely based on practical experience. A series of experiments was undertaken to delineate the optimal mixer orifice geometry. A cross-flow to core-flow momentum-flux ratio of 40 and a mass flow ratio of 2.5 were selected as representative of an advanced design. An experimental test matrix was designed around three variables: the number of orifices, the orifice aspect ratio (long-to-short dimension), and the orifice angle. A regression analysis was performed on the data to arrive at an interpolating equation that predicted the mixing performance of orifice geometry combinations within the range of the test matrix parameters. Results indicate that mixture uniformity is a non-linear function of the number of orifices, the orifice aspect ratio, and the orifice angle. Optimum mixing occurs when the asymptotic mean jet trajectories are in the range of 0.35 less than r/R less than 0.5 (where r = 0 is at the mixer wall) at z/R = 1.0. At the optimum number of orifices, the difference between shallow-angled slots with large aspect ratios and round holes is minimal and either approach will lead to good mixing performance. At the optimum number of orifices, it appears possible to have two local optimums where one corresponds to an aspect ratio of 1.0 and the other to a high aspect ratio.
The Future of the U.S. Intercontinental Ballistic Missile Force
2014-01-01
42 3.7. Nevada Test Range and Surrounding Areas . . . . . . . . . . . . . . . . . . . . . 44 4.1. Solid Rocket ... Rocket Mass Ratio . . . 62 4.6. Range of an ICBM from Current Missile Bases . . . . . . . . . . . . . . . . 64 4.7. Range of an ICBM from Expanded...38 4.1. Specific Impulse of Various Rocket Propellants
USDA-ARS?s Scientific Manuscript database
We evaluated shortgrass steppe energy budgets based on the Bowen Ratio Energy Balance method for three different grazing intensity treatments at the Central Plains Experimental Range Long-Term Ecological Research (CPER-LTER) site. We tested the correlations between aboveground biomass and surface en...
Logistic Approximation to the Normal: The KL Rationale
ERIC Educational Resources Information Center
Savalei, Victoria
2006-01-01
A rationale is proposed for approximating the normal distribution with a logistic distribution using a scaling constant based on minimizing the Kullback-Leibler (KL) information, that is, the expected amount of information available in a sample to distinguish between two competing distributions using a likelihood ratio (LR) test, assuming one of…
Describes procedures written based on the assumption that they will be performed by analysts who are formally trained in at least the basic principles of chemical analysis and in the use of the subject technology.
MIR hollow waveguide (HWG) isotope ratio analyzer for environmental applications
NASA Astrophysics Data System (ADS)
Wang, Zhenyou; Zhuang, Yan; Deev, Andrei; Wu, Sheng
2017-05-01
An advanced commercial Mid-InfraRed Isotope Ratio (IR2) analyzer was developed in Arrow Grand Technologies based on hollow waveguide (HWG) as the sample tube. The stable carbon isotope ratio, i.e. δ13C, was obtained by measuring the selected CO2 absorption peaks in the MIR. Combined with a GC and a combustor, it has been successfully employed to measure compound specific δ13C isotope ratios in the field. By using both the 1- pass HWG and 5-path HWG, we are able to measure δ13C isotope ratio at a broad CO2 concentration of 300 ppm-37,500 ppm. Here, we demonstrate its applications in environmental studies. The δ13C isotope ratio and concentration of CO2 exhaled by soil samples was measured in real time with the isotope analyzer. The concentration was found to change with the time. We also convert the Dissolved Inorganic Carbon (DIC) into CO2, and then measure the δ13C isotope ratio with an accuracy of better than 0.3 ‰ (1 σ) with a 6 min test time and 1 ml sample usage. Tap water, NaHCO3 solvent, coca, and even beer were tested. Lastly, the 13C isotope ratio of CO2 exhaled by human beings was obtained <10 seconds after simply blowing the exhaled CO2 into a tube with an accuracy of 0.5‰ (1 σ) without sample preconditioning. In summary, a commercial HWG isotope analyzer was demonstrated to be able to perform environmental and health studies with a high accuracy ( 0.3 ‰/Hz1/2 1 σ), fast sampling rate (up to 10 Hz), low sample consumption ( 1 ml), and broad CO2 concentration range (300 ppm-37,500 ppm).
Diagnostic accuracy of FEV1/forced vital capacity ratio z scores in asthmatic patients.
Lambert, Allison; Drummond, M Bradley; Wei, Christine; Irvin, Charles; Kaminsky, David; McCormack, Meredith; Wise, Robert
2015-09-01
The FEV1/forced vital capacity (FVC) ratio is used as a criterion for airflow obstruction; however, the test characteristics of spirometry in the diagnosis of asthma are not well established. The accuracy of a test depends on the pretest probability of disease. We wanted to estimate the FEV1/FVC ratio z score threshold with optimal accuracy for the diagnosis of asthma for different pretest probabilities. Asthmatic patients enrolled in 4 trials from the Asthma Clinical Research Centers were included in this analysis. Measured and predicted FEV1/FVC ratios were obtained, with calculation of z scores for each participant. Across a range of asthma prevalences and z score thresholds, the overall diagnostic accuracy was calculated. One thousand six hundred eight participants were included (mean age, 39 years; 71% female; 61% white). The mean FEV1 percent predicted value was 83% (SD, 15%). In a symptomatic population with 50% pretest probability of asthma, optimal accuracy (68%) is achieved with a z score threshold of -1.0 (16th percentile), corresponding to a 6 percentage point reduction from the predicted ratio. However, in a screening population with a 5% pretest probability of asthma, the optimum z score is -2.0 (second percentile), corresponding to a 12 percentage point reduction from the predicted ratio. These findings were not altered by markers of disease control. Reduction of the FEV1/FVC ratio can support the diagnosis of asthma; however, the ratio is neither sensitive nor specific enough for diagnostic accuracy. When interpreting spirometric results, consideration of the pretest probability is an important consideration in the diagnosis of asthma based on airflow limitation. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Reliability of Soft Tissue Model Based Implant Surgical Guides; A Methodological Mistake.
Sabour, Siamak; Dastjerdi, Elahe Vahid
2012-08-20
Abstract We were interested to read the paper by Maney P and colleagues published in the July 2012 issue of J Oral Implantol. The authors aimed to assess the reliability of soft tissue model based implant surgical guides reported that the accuracy was evaluated using software. 1 I found the manuscript title of Maney P, et al. incorrect and misleading. Moreover, they reported twenty-two sites (46.81%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). As the authors point out in their conclusion, Soft tissue models do not always provide sufficient accuracy for implant surgical guide fabrication.Reliability (precision) and validity (accuracy) are two different methodological issues in researches. Sensitivity, specificity, PPV, NPV, likelihood ratio positive (true positive/false negative) and likelihood ratio negative (false positive/ true negative) as well as odds ratio (true results\\false results - preferably more than 50) are among the tests to evaluate the validity (accuracy) of a single test compared to a gold standard.2-4 It is not clear that the reported twenty-two sites (46.81%) which were considered accurate related to which of the above mentioned estimates for validity analysis. Reliability (repeatability or reproducibility) is being assessed by different statistical tests such as Pearson r, least square and paired t.test which all of them are among common mistakes in reliability analysis 5. Briefly, for quantitative variable Intra Class Correlation Coefficient (ICC) and for qualitative variables weighted kappa should be used with caution because kappa has its own limitation too. Regarding reliability or agreement, it is good to know that for computing kappa value, just concordant cells are being considered, whereas discordant cells should also be taking into account in order to reach a correct estimation of agreement (Weighted kappa).2-4 As a take home message, for reliability and validity analysis, appropriate tests should be applied.
Design of a fuzzy differential evolution algorithm to predict non-deposition sediment transport
NASA Astrophysics Data System (ADS)
Ebtehaj, Isa; Bonakdari, Hossein
2017-12-01
Since the flow entering a sewer contains solid matter, deposition at the bottom of the channel is inevitable. It is difficult to understand the complex, three-dimensional mechanism of sediment transport in sewer pipelines. Therefore, a method to estimate the limiting velocity is necessary for optimal designs. Due to the inability of gradient-based algorithms to train Adaptive Neuro-Fuzzy Inference Systems (ANFIS) for non-deposition sediment transport prediction, a new hybrid ANFIS method based on a differential evolutionary algorithm (ANFIS-DE) is developed. The training and testing performance of ANFIS-DE is evaluated using a wide range of dimensionless parameters gathered from the literature. The input combination used to estimate the densimetric Froude number ( Fr) parameters includes the volumetric sediment concentration ( C V ), ratio of median particle diameter to hydraulic radius ( d/R), ratio of median particle diameter to pipe diameter ( d/D) and overall friction factor of sediment ( λ s ). The testing results are compared with the ANFIS model and regression-based equation results. The ANFIS-DE technique predicted sediment transport at limit of deposition with lower root mean square error (RMSE = 0.323) and mean absolute percentage of error (MAPE = 0.065) and higher accuracy ( R 2 = 0.965) than the ANFIS model and regression-based equations.
Liu, Boquan; Polce, Evan; Sprott, Julien C; Jiang, Jack J
2018-05-17
The purpose of this study is to introduce a chaos level test to evaluate linear and nonlinear voice type classification method performances under varying signal chaos conditions without subjective impression. Voice signals were constructed with differing degrees of noise to model signal chaos. Within each noise power, 100 Monte Carlo experiments were applied to analyze the output of jitter, shimmer, correlation dimension, and spectrum convergence ratio. The computational output of the 4 classifiers was then plotted against signal chaos level to investigate the performance of these acoustic analysis methods under varying degrees of signal chaos. A diffusive behavior detection-based chaos level test was used to investigate the performances of different voice classification methods. Voice signals were constructed by varying the signal-to-noise ratio to establish differing signal chaos conditions. Chaos level increased sigmoidally with increasing noise power. Jitter and shimmer performed optimally when the chaos level was less than or equal to 0.01, whereas correlation dimension was capable of analyzing signals with chaos levels of less than or equal to 0.0179. Spectrum convergence ratio demonstrated proficiency in analyzing voice signals with all chaos levels investigated in this study. The results of this study corroborate the performance relationships observed in previous studies and, therefore, demonstrate the validity of the validation test method. The presented chaos level validation test could be broadly utilized to evaluate acoustic analysis methods and establish the most appropriate methodology for objective voice analysis in clinical practice.
Bond–Slip Relationship for CFRP Sheets Externally Bonded to Concrete under Cyclic Loading
Li, Ke; Cao, Shuangyin; Yang, Yue; Zhu, Juntao
2018-01-01
The objective of this paper was to explore the bond–slip relationship between carbon fiber-reinforced polymer (CFRP) sheets and concrete under cyclic loading through experimental and analytical approaches. Modified beam tests were performed in order to gain insight into the bond–slip relationship under static and cyclic loading. The test variables are the CFRP-to-concrete width ratio, and the bond length of the CFRP sheets. An analysis of the test results in this paper and existing test results indicated that the slope of the ascending segment of the bond–slip curve decreased with an increase in the number of load cycles, but the slip corresponding to the maximum shear stress was almost invariable as the number of load cycles increased. In addition, the rate of reduction in the slope of the ascending range of the bond–slip curve during cyclic loading decreased as the concrete strength increased, and increased as the load level or CFRP-to-concrete width ratio enhanced. However, these were not affected by variations in bond length if the residual bond length was longer than the effective bond length. A bilinear bond–slip model for CFRP sheets that are externally bonded to concrete under cyclic loading, which considered the effects of the cyclic load level, concrete strength, and CFRP-to-concrete ratio, was developed based on the existing static bond–slip model. The accuracy of this proposed model was verified by a comparison between this proposed model and test results. PMID:29495383
Bond-Slip Relationship for CFRP Sheets Externally Bonded to Concrete under Cyclic Loading.
Li, Ke; Cao, Shuangyin; Yang, Yue; Zhu, Juntao
2018-02-26
The objective of this paper was to explore the bond-slip relationship between carbon fiber-reinforced polymer (CFRP) sheets and concrete under cyclic loading through experimental and analytical approaches. Modified beam tests were performed in order to gain insight into the bond-slip relationship under static and cyclic loading. The test variables are the CFRP-to-concrete width ratio, and the bond length of the CFRP sheets. An analysis of the test results in this paper and existing test results indicated that the slope of the ascending segment of the bond-slip curve decreased with an increase in the number of load cycles, but the slip corresponding to the maximum shear stress was almost invariable as the number of load cycles increased. In addition, the rate of reduction in the slope of the ascending range of the bond-slip curve during cyclic loading decreased as the concrete strength increased, and increased as the load level or CFRP-to-concrete width ratio enhanced. However, these were not affected by variations in bond length if the residual bond length was longer than the effective bond length. A bilinear bond-slip model for CFRP sheets that are externally bonded to concrete under cyclic loading, which considered the effects of the cyclic load level, concrete strength, and CFRP-to-concrete ratio, was developed based on the existing static bond-slip model. The accuracy of this proposed model was verified by a comparison between this proposed model and test results.
Castinetti, F; Morange, I; Dufour, H; Jaquet, P; Conte-Devolx, B; Girard, N; Brue, T
2007-09-01
Corticotropin-releasing hormone (CRH)-stimulated petrosal sinus sampling is currently the gold standard method for the differential diagnosis between pituitary and ectopic ACTH-dependent Cushing's syndrome. Our objective was to determine sensitivity and specificity of desmopressin test during petrosal sinus sampling. Forty-three patients had petrosal sinus sampling because of the lack of visible adenoma on magnetic resonance imaging (MRI) and/or because of discordant cortisol response to high-dose dexamethasone suppression test. ACTH sampling was performed in an antecubital vein, right and left petrosal sinuses, then at each location 5 and 10 min after injection of desmopressin. Diagnosis was based on the ACTH ratio between petrosal sinus and humeral vein ACTH after desmopressin test. Diagnosis was confirmed after surgery. A receiver operating characteristics curve was used to determine optimal sensitivity and specificity. Thirty-six patients had Cushing's disease (CD) and seven had ectopic ACTH secretion. A ratio > 2 after desmopressin was found in 35 of the 36 cases of CD (sensitivity: 95%). A ratio < or = 2 was found in the seven patients with ectopic ACTH secretion (specificity: 100%). Sinus sampling was ineffective in determining the left or right localization of the adenoma (sensitivity = 50%). No major adverse effects were observed during or after the procedure. Desmopressin test during petrosal sinus sampling is a safe and effective diagnostic procedure in ACTH-dependent Cushing's syndrome. It thus represents a valuable alternative to CRH.
Development of a Field-Deployable Methane Carbon Isotope Analyzer
NASA Astrophysics Data System (ADS)
Dong, Feng; Baer, Douglas
2010-05-01
Methane is a potent greenhouse gas, whose atmospheric surface mixing ratio has almost doubled compared with preindustrial values. Methane can be produced by biogenic processes, thermogenic processes or biomass, with different isotopic signatures. As a key molecule involved in the radiative forcing in the atmosphere, methane is thus one of the most important molecules linking the biosphere and atmosphere. Therefore precise measurements of mixing ratios and isotopic compositions will help scientists to better understand methane sources and sinks. To date, high precision isotope measurements have been exclusively performed with conventional isotope ratio mass spectrometry, which involves intensive labor and is not readily field deployable. Optical studies using infrared laser spectroscopy have also been reported to measure the isotopic ratios. However, the precision of optical-based analyses, to date, is typically unsatisfactory without pre-concentration procedures. We present characterization of the performance of a portable Methane Carbon Isotope Analyzer (MCIA), based on cavity enhanced laser absorption spectroscopy technique, that provides in-situ measurements of the carbon isotope ratio (13C/12C or del_13C) and methane mixing ratio (CH4). The sample is introduced to the analyzer directly without any requirement for pretreatment or preconcentration. A typical precision of less than 1 per mill (< 0.1%) with a 10-ppm methane sample can be achieved in a measurement time of less than 100 seconds. The MCIA can report carbon isotope ratio and concentration measurements over a very wide range of methane concentrations. Results of laboratory tests and field measurements will be presented.
Determining the slag fraction, water/binder ratio and degree of hydration in hardened cement pastes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yio, M.H.N., E-mail: marcus.yio11@imperial.ac.uk; Phelan, J.C.; Wong, H.S.
2014-02-15
A method for determining the original mix composition of hardened slag-blended cement-based materials based on analysis of backscattered electron images combined with loss on ignition measurements is presented. The method does not require comparison to reference standards or prior knowledge of the composition of the binders used. Therefore, it is well-suited for application to real structures. The method is also able to calculate the degrees of reaction of slag and cement. Results obtained from an experimental study involving sixty samples with a wide range of water/binder (w/b) ratios (0.30 to 0.50), slag/binder ratios (0 to 0.6) and curing ages (3more » days to 1 year) show that the method is very promising. The mean absolute errors for the estimated slag, water and cement contents (kg/m{sup 3}), w/b and s/b ratios were 9.1%, 1.5%, 2.5%, 4.7% and 8.7%, respectively. 91% of the estimated w/b ratios were within 0.036 of the actual values. -- Highlights: •A new method for estimating w/b ratio and slag content in cement pastes is proposed. •The method is also able to calculate the degrees of reaction of slag and cement. •Reference standards or prior knowledge of the binder composition are not required. •The method was tested on samples with varying w/b ratios and slag content.« less
NASA Technical Reports Server (NTRS)
Birch, J. N.; Getzin, N.
1971-01-01
Analog and digital voice coding techniques for application to an L-band satellite-basedair traffic control (ATC) system for over ocean deployment are examined. In addition to performance, the techniques are compared on the basis of cost, size, weight, power consumption, availability, reliability, and multiplexing features. Candidate systems are chosen on the bases of minimum required RF bandwidth and received carrier-to-noise density ratios. A detailed survey of automated and nonautomated intelligibility testing methods and devices is presented and comparisons given. Subjective evaluation of speech system by preference tests is considered. Conclusion and recommendations are developed regarding the selection of the voice system. Likewise, conclusions and recommendations are developed for the appropriate use of intelligibility tests, speech quality measurements, and preference tests with the framework of the proposed ATC system.
Brittleness of twig bases in the genus Salix: fracture mechanics and ecological relevance.
Beismann, H; Wilhelmi, H; Baillères, H; Spatz, H C; Bogenrieder, A; Speck, T
2000-03-01
The twig bases within the genus Salix were investigated. Brittleness of twig bases as defined in the literature neither correlates with Young's modulus nor with growth strains, which were measured for S. alba, S. fragilis and S. x rubens. For the species S. alba, S. appendiculata, S. eleagnos, S. fragilis, S. purpurea, S. triandra, S. viminalis, and S. x rubens, fracture surfaces of broken twigs were investigated and semiquantitatively described in terms of 'relative roughness' (ratio of rough area of fracture surface over whole area of fracture surface). The relative roughness clearly corresponds with the classification into brittle and nonbrittle species given in the literature. An attempt was made to quantify brittleness with mechanical tests. The absolute values of stress and strain do not correlate with the brittleness of the twig bases as defined by the relative roughness. However, the 'index stress' (ratio of stress at yield over stress at fracture) or the 'index strain' (ratio of strain at yield over strain at fracture), correlate well with the relative roughness. The graphic analysis of index stress against index strain reveals a straight line on which the eight species are ordered according to their brittleness. Depending on growth form and habitat, brittle twig bases of willows may function ecologically as mechanical safety mechanisms and, additionally, as a propagation mechanism.
[Remote system of natural gas leakage based on multi-wavelength characteristics spectrum analysis].
Li, Jing; Lu, Xu-Tao; Yang, Ze-Hui
2014-05-01
In order to be able to quickly, to a wide range of natural gas pipeline leakage monitoring, the remote detection system for concentration of methane gas was designed based on static Fourier transform interferometer. The system used infrared light, which the center wavelength was calibrated to absorption peaks of methane molecules, to irradiated tested area, and then got the interference fringes by converging collimation system and interference module. Finally, the system calculated the concentration-path-length product in tested area by multi-wavelength characteristics spectrum analysis algorithm, furthermore the inversion of the corresponding concentration of methane. By HITRAN spectrum database, Selected wavelength position of 1. 65 microm as the main characteristic absorption peaks, thereby using 1. 65 pm DFB laser as the light source. In order to improve the detection accuracy and stability without increasing the hardware configuration of the system, solved absorbance ratio by the auxiliary wave-length, and then get concentration-path-length product of measured gas by the method of the calculation proportion of multi-wavelength characteristics. The measurement error from external disturbance is caused by this innovative approach, and it is more similar to a differential measurement. It will eliminate errors in the process of solving the ratio of multi-wavelength characteristics, and can improve accuracy and stability of the system. The infrared absorption spectrum of methane is constant, the ratio of absorbance of any two wavelengths by methane is also constant. The error coefficients produced by the system is the same when it received the same external interference, so the measured noise of the system can be effectively reduced by the ratio method. Experimental tested standards methane gas tank with leaking rate constant. Using the tested data of PN1000 type portable methane detector as the standard data, and were compared to the tested data of the system, while tested distance of the system were 100, 200 and 500 m. Experimental results show that the methane concentration detected value was stable after a certain time leakage, the concentration-path-length product value of the system was stable. For detection distance of 100 m, the detection error of the concentration-path-length product was less than 1. 0%. With increasing distance from tested area, the detection error is increased correspondingly. When the distance was 500 m, the detection error was less than 4. 5%. In short, the detected error of the system is less than 5. 0% after the gas leakage stable, to meet the requirements of the field of natural gas leakage remote sensing.
Comparative effectiveness of allergy testing method in driving immunotherapy outcomes.
Kaffenberger, Thomas M; Dedhia, Raj C; Schwarzbach, Hannah L; Mady, Leila J; Lee, Stella E
2018-05-01
Skin-prick testing (SPT), in vitro testing (IVT), and intradermal-dilutional testing (IDT) are methods to detect patient sensitivities to specific allergens and direct immunotherapy dosing. We used objective and subjective measures of improvement to compare outcomes based on test method. Patients underwent 1 of 3 protocols: SPT, screening SPT followed by IDT, or IVT. We used institution billing data to do a cost analysis of these tests. The time to maintenance (TTM) therapy was analyzed and patients were stratified into high and low reactors. The Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) was used to quantify symptoms pre-maintenance and post-maintenance. Of 177 patients (SPT, n = 40; IVT, n = 91; IDT, n = 46), 115 (SPT, n = 35; IVT, n = 39; IDT, n = 41) were high reactors. Out of 90 patients (SPT, n = 17; IVT, n = 37; IDT, n = 36) reaching maintenance, 58 were high reactors (SPT, n = 15; IVT, n = 12; IDT, n = 31). Overall, SPT, IVT, and IDT median TTM were 542, 329, and 578.5 days, respectively. IDT TTM was shorter compared to IVT overall and in high reactors (hazard ratio [HR] = 1.91, p = 0.02; HR = 2.12, p = 0.03), but was not significant compared to SPT high reactors (p = 0.33). The IDT cost was $62.66, translating to an incremental cost-effectiveness ratio of $0.23 per day of shortened TTM. Median RQLQ change for the SPT, IVT, and IDT groups was 6.5, 1, and 1.5, respectively, but was not significant (p = 0.60). IDT reached maintenance immunotherapy quicker than IVT but there was no difference compared to SPT. TTM did not correlate with improvements in patient symptoms between testing methods. This study represents a novel comparison of outcomes based on initial allergy testing method. © 2017 ARS-AAOA, LLC.
Dinesen, L; Caspary, W F; Chapman, R W; Dietrich, C F; Sarrazin, C; Braden, B
2008-09-01
The (13)C-methacetin-breath test and also several noninvasive blood tests comprising routine laboratory parameters have been proposed to predict fibrosis and cirrhosis in chronic hepatitis C. The aim of the study was to compare the diagnostic accuracy between these tests referring to hepatic histology as gold standard. 96 patients with chronic hepatitis C virus infection underwent percutaneous liver biopsy and the (13)C-methacetin-breath test. The Fibroindex, the aspartate aminotransferase to platelet ratio index , and the aspartate aminotransferase to alanine aminotransferase ratio were used as parameters for the staging of fibrosis. The main endpoint was the area under the characteristic curves for the diagnosis of advanced fibrosis (F3-F4) and cirrhosis (F4) according to the Batts Ludwig criteria. ROC analysis revealed a cut-off <14.6 per thousand best with 92.6% sensitivity and 84.1% specificity for the (13)C-methacetin-breath test, for the Fibroindex >1.82 70.4% sensitivity and 91.3% specificity, for the aspartate aminotransferase to platelet ratio >1.0 a 66.7% sensitivity and 75.4% specificity, and for the aspartate aminotransferase to alanine aminotransferase ratio >1.0 63.0% sensitivity and 59.4% specificity in predicting liver cirrhosis. The areas under the curve for the breath test, the Fibroindex, aspartate aminotransferase to platelet ratio and the aspartate aminotransferase to alanine aminotransferase ratio were 0.958, 0.845, 0.799, and 0.688, respectively, when predicting cirrhosis. For identifying patients with advanced fibrosis, the areas under the curve were 0.827, 0.804, 0.779, and 0.561, respectively. Discordances between Fibroindex (21%), aspartate aminotransferase to platelet ratio (29%) or aspartate aminotransferase to alanine aminotransferase ratio (37.6%) and liver biopsy were significantly more frequent than between (13)C-breath test (11.6%) and liver biopsy (P<0.05). The (13)C-methacetin-breath test is more reliable in predicting advanced fibrosis and cirrhosis than simple biochemical parameters (aspartate aminotransferase to platelet ratio; aspartate aminotransferase to alanine aminotransferase ratio).
Sull, Jae Woong; Liang, Kung-Yee; Hetmanski, Jacqueline B; Fallin, M Daniele; Ingersoll, Roxanne G; Park, Ji Wan; Wu-Chou, Yah-Huei; Chen, Philip K; Chong, Samuel S; Cheah, Felicia; Yeow, Vincent; Park, Beyoung Yun; Jee, Sun Ha; Jabs, Ethylin W; Redett, Richard; Scott, Alan F; Beaty, Terri H
2008-09-15
Isolated cleft palate is among the most common human birth defects. The TCOF1 gene has been suggested as a candidate gene for cleft palate based on animal models. This study tests for association between markers in TCOF1 and isolated, nonsyndromic cleft palate using a case-parent trio design considering parent-of-origin effects. Case-parent trios from three populations (comprising a total of 81 case-parent trios) were genotyped for single nucleotide polymorphisms (SNPs) in the TCOF1 gene. We used the transmission disequilibrium test and the transmission asymmetry test on individual SNPs. When all trios were combined, the odds ratio for transmission of the minor allele, OR(transmission), was significant for SNP rs15251 (OR = 2.88, P = 0.007), as well as rs2255796 and rs2569062 (OR = 2.08, P = 0.03; OR = 2.43, P = 0.041; respectively) when parent of origin was not considered. The transmission asymmetry test also revealed one SNP (rs15251) showing excess maternal transmission significant at the P = 0.005 level (OR = 6.50). Parent-of-origin effects were assessed using the parent-of-origin likelihood ratio test on both SNPs and haplotypes. While the parent-of-origin likelihood ratio test was only marginally significant for this SNP (P = 0.136), analysis of haplotypes of rs2255796 and rs15251 suggested excess maternal transmission. Therefore, these data suggest TCOF1 may influence risk of cleft palate through a parent-of-origin effect. Copyright 2008 Wiley-Liss, Inc.
Nguyen, Hoang T; Merriman, Tony R; Black, Michael A
2014-01-01
Recent advances in high-throughout sequencing technologies have made it possible to accurately assign copy number (CN) at CN variable loci. However, current analytic methods often perform poorly in regions in which complex CN variation is observed. Here we report the development of a read depth-based approach, CNVrd2, for investigation of CN variation using high-throughput sequencing data. This methodology was developed using data from the 1000 Genomes Project from the CCL3L1 locus, and tested using data from the DEFB103A locus. In both cases, samples were selected for which paralog ratio test data were also available for comparison. The CNVrd2 method first uses observed read-count ratios to refine segmentation results in one population. Then a linear regression model is applied to adjust the results across multiple populations, in combination with a Bayesian normal mixture model to cluster segmentation scores into groups for individual CN counts. The performance of CNVrd2 was compared to that of two other read depth-based methods (CNVnator, cn.mops) at the CCL3L1 and DEFB103A loci. The highest concordance with the paralog ratio test method was observed for CNVrd2 (77.8/90.4% for CNVrd2, 36.7/4.8% for cn.mops and 7.2/1% for CNVnator at CCL3L1 and DEF103A). CNVrd2 is available as an R package as part of the Bioconductor project: http://www.bioconductor.org/packages/release/bioc/html/CNVrd2.html.
Memory Binding Test Predicts Incident Amnestic Mild Cognitive Impairment.
Mowrey, Wenzhu B; Lipton, Richard B; Katz, Mindy J; Ramratan, Wendy S; Loewenstein, David A; Zimmerman, Molly E; Buschke, Herman
2016-07-14
The Memory Binding Test (MBT), previously known as Memory Capacity Test, has demonstrated discriminative validity for distinguishing persons with amnestic mild cognitive impairment (aMCI) and dementia from cognitively normal elderly. We aimed to assess the predictive validity of the MBT for incident aMCI. In a longitudinal, community-based study of adults aged 70+, we administered the MBT to 246 cognitively normal elderly adults at baseline and followed them annually. Based on previous work, a subtle reduction in memory binding at baseline was defined by a Total Items in the Paired (TIP) condition score of ≤22 on the MBT. Cox proportional hazards models were used to assess the predictive validity of the MBT for incident aMCI accounting for the effects of covariates. The hazard ratio of incident aMCI was also assessed for different prediction time windows ranging from 4 to 7 years of follow-up, separately. Among 246 controls who were cognitively normal at baseline, 48 developed incident aMCI during follow-up. A baseline MBT reduction was associated with an increased risk for developing incident aMCI (hazard ratio (HR) = 2.44, 95% confidence interval: 1.30-4.56, p = 0.005). When varying the prediction window from 4-7 years, the MBT reduction remained significant for predicting incident aMCI (HR range: 2.33-3.12, p: 0.0007-0.04). Persons with poor performance on the MBT are at significantly greater risk for developing incident aMCI. High hazard ratios up to seven years of follow-up suggest that the MBT is sensitive to early disease.
NASA Astrophysics Data System (ADS)
Patel, Shantanu; Martin, C. Derek
2018-02-01
Unlike metals, rocks show bi-modularity (different Young's moduli and Poisson's ratios in compression and tension). Displacements monitored during the Brazilian test are used in this study to obtain the Young's modulus and Poisson's ratio in tension. New equations for the displacements in a Brazilian test are derived considering the bi-modularity in the stress-strain relations. The digital image correlation technique was used to monitor the displacements of the Brazilian disk flat surface. To validate the Young's modulus and Poisson's ratio obtained from the Brazilian test, the results were compared with the values from the direct tension tests. The results obtained from the Brazilian test were repetitive and within 3.5% of the value obtained from the direct tension test for the rock tested.
Sex ratio of equine offspring is affected by the ages of the mare and stallion.
Santos, Marianna Machado; Maia, Leonardo Lara; Nobre, Daniel Magalhães; Oliveira Neto, José Ferraz; Garcia, Tiago Rezende; Lage, Maria Coeli Gomes Reis; de Melo, Maria Isabel Vaz; Viana, Walmir Santos; Palhares, Maristela Silveira; da Silva Filho, José Monteiro; Santos, Renato Lima; Valle, Guilherme Ribeiro
2015-10-15
The aim of this study was to determine the influence of parental age on the sex ratio of offspring in horses. Two trials were performed. In the first trial, the data from a randomly obtained population with a 1:1 sex ratio of 59,950 Mangalarga Marchador horses born in Brazil from 1990 to 2011 were analyzed. The sex ratios of the offspring were compared among groups according to the mare and the stallion ages (from 3 to 25 years). In the first step of the analysis, the mares and stallions were grouped according to age in 5-year intervals. In the second step, the groups were based on the parental age gap at conception. In the third step, the group of the mares and stallions with similar ages from the second step was subdivided, and the different parental age subgroups that were divided into 5-year intervals were compared. In the fourth step, the sex ratio of the offspring was determined according to the ages of the mares and the stallions at conception. The second trial was based on the data from 253 horses of several breeds that were born after natural gestation into a herd from 1989 to 2010, and the offspring of groups that were younger or older than 15 years were compared. The data from both trials were analyzed using a chi-square test (P ≤ 0.01 for the first trial; and P ≤ 0.05 for the second trial) for the comparisons of the sex ratios. In the first trial, the Spearman test (P ≤ 0.01) was used to verify the correlations between the parental age and the offspring sex ratio. In the first trial, the offspring sex ratio decreased as the mare or stallion age increased, and the decrease was more marked for the mares than for the stallions. In the second trial, the mares older than 15 years had more fillies than the younger mares, but the stallion age had no effect on the sex of the offspring. The first trial, with a large number of horses, revealed the pattern of the distribution of the sex ratios of offspring according to the parental age in horses, whereas the second trial, with a more restricted number of horses, confirmed the influence of the age of the mare on the offspring sex ratio. We concluded that the parental age affected the offspring sex ratio in horses and that this effect was stronger for the mares than for the stallions. Copyright © 2015 Elsevier Inc. All rights reserved.
A Graphic Chi-Square Test For Two-Class Genetic Segregation Ratios
A.E. Squillace; D.J. Squillace
1970-01-01
A chart is presented for testing the goodness of fit of observed two-class genetic segregation ratios against hypothetical ratios, eliminating the need of computing chi-square. Although designed mainly for genetic studies, the chart can also be used for other types of studies involving two-class chi-square tests.
Sloan, Jamison; Sun, Yunwei; Carrigan, Charles
2016-05-01
Enforcement of the Comprehensive Nuclear Test Ban Treaty (CTBT) will involve monitoring for radiologic indicators of underground nuclear explosions (UNEs). A UNE produces a variety of radioisotopes which then decay through connected radionuclide chains. A particular species of interest is xenon, namely the four isotopes (131m)Xe, (133m)Xe, (133)Xe, and (135)Xe. Due to their half lives, some of these isotopes can exist in the subsurface for more than 100 days. This convenient timescale, combined with modern detection capabilities, makes the xenon family a desirable candidate for UNE detection. Ratios of these isotopes as a function of time have been studied in the past for distinguishing nuclear explosions from civilian nuclear applications. However, the initial yields from UNEs have been treated as fixed values. In reality, these independent yields are uncertain to a large degree. This study quantifies the uncertainty in xenon ratios as a result of these uncertain initial conditions to better bound the values that xenon ratios can assume. We have successfully used a combination of analytical and sampling based statistical methods to reliably bound xenon isotopic ratios. We have also conducted a sensitivity analysis and found that xenon isotopic ratios are primarily sensitive to only a few of many uncertain initial conditions. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Vandevijvere, Stefanie; Mackenzie, Tara; Mhurchu, Cliona Ni
2017-04-26
In-store availability of healthy and unhealthy foods may influence consumer purchases. Methods used to measure food availability, however, vary widely. A simple, valid, and reliable indicator to collect comparable data on in-store food availability is needed. Cumulative linear shelf length of and variety within 22 healthy and 28 unhealthy food groups, determined based on a comparison of three nutrient profiling systems, were measured in 15 New Zealand supermarkets. Inter-rater reliability was tested in one supermarket by a second researcher. The construct validity of five simple indicators of relative availability of healthy versus unhealthy foods was assessed against this 'gold standard'. Cumulative linear shelf length was a more sensitive and feasible measure of food availability than variety. Four out of five shelf length ratio indicators were significantly associated with the gold standard (ρ = 0.70-0.75). Based on a non-significant difference from the 'gold standard' (d = 0.053 ± 0.040) and feasibility, the ratio of cumulative linear shelf length of fresh and frozen fruits and vegetables versus soft and energy drinks, crisps and snacks, sweet biscuits and confectionery performed best for use in New Zealand supermarkets. Four out of the five shelf length ratio indicators of the relative availability of healthy versus unhealthy foods in-store tested could be used for future research and monitoring, but additional validation studies in other settings and countries are recommended. Consistent use of those shelf length ratio indicators could enhance comparability of supermarket food availability between studies, and help inform policies to create healthy consumer food retail environments.
NASA Technical Reports Server (NTRS)
Meyer, Carl L.; Branstetter, J. Robert
1946-01-01
Results are reported of knock-limited tests of five aromatics, each individually blended with selected base fuels and tested with and without TEL, using 17.6, F-4, and F-3 small-scale engines. The five aromatics rated in the following order of decreasing antiknock effectiveness at fuel/air ratio 0.10: m-xylene, 1-isopropyl-4-methylbenzene, n-propylbenzene, isobutylbenzene, and n-butylbenzene.
NASA Technical Reports Server (NTRS)
1987-01-01
The UDF trademark (Unducted Fan) engine is a new aircraft engine concept based on an ungeared, counterrotating, unducted, ultra-high-bypass turbofan configuration. This engine is being developed to provide a high thrust-to-weight ratio powerplant with exceptional fuel efficiency for subsonic aircraft application. This report covers the testing of pertinent components of this engine such as the fan blades, control and actuation system, turbine blades and spools, seals, and mixer frame.
Xu, Xu Steven; Yuan, Min; Yang, Haitao; Feng, Yan; Xu, Jinfeng; Pinheiro, Jose
2017-01-01
Covariate analysis based on population pharmacokinetics (PPK) is used to identify clinically relevant factors. The likelihood ratio test (LRT) based on nonlinear mixed effect model fits is currently recommended for covariate identification, whereas individual empirical Bayesian estimates (EBEs) are considered unreliable due to the presence of shrinkage. The objectives of this research were to investigate the type I error for LRT and EBE approaches, to confirm the similarity of power between the LRT and EBE approaches from a previous report and to explore the influence of shrinkage on LRT and EBE inferences. Using an oral one-compartment PK model with a single covariate impacting on clearance, we conducted a wide range of simulations according to a two-way factorial design. The results revealed that the EBE-based regression not only provided almost identical power for detecting a covariate effect, but also controlled the false positive rate better than the LRT approach. Shrinkage of EBEs is likely not the root cause for decrease in power or inflated false positive rate although the size of the covariate effect tends to be underestimated at high shrinkage. In summary, contrary to the current recommendations, EBEs may be a better choice for statistical tests in PPK covariate analysis compared to LRT. We proposed a three-step covariate modeling approach for population PK analysis to utilize the advantages of EBEs while overcoming their shortcomings, which allows not only markedly reducing the run time for population PK analysis, but also providing more accurate covariate tests.
Optimization of Orifice Geometry for Cross-Flow Mixing in a Cylindrical Duct
NASA Technical Reports Server (NTRS)
Kroll, J. T.; Sowa, W. A.; Samuelsen, G. S.
1996-01-01
Mixing of gaseous jets in a cross-flow has significant applications in engineering, one example of which is the dilution zone of a gas turbine combustor. Despite years of study, the design of the jet injection in combustors is largely based on practical experience. The emergence of NO(x) regulations for stationary gas turbines and the anticipation of aero-engine regulations requires an improved understanding of jet mixing as new combustor concepts are introduced. For example, the success of the staged combustor to reduce the emission of NO(x) is almost entirely dependent upon the rapid and complete dilution of the rich zone products within the mixing section. It is these mixing challenges to which the present study is directed. A series of experiments was undertaken to delineate the optimal mixer orifice geometry. A cross-flow to core-flow momentum-flux ratio of 40 and a mass flow ratio of 2.5 were selected as representative of a conventional design. An experimental test matrix was designed around three variables: the number of orifices, the orifice length-to- width ratio, and the orifice angle. A regression analysis was performed on the data to arrive at an interpolating equation that predicted the mixing performance of orifice geometry combinations within the range of the test matrix parameters. Results indicate that the best mixing orifice geometry tested involves eight orifices with a long-to-short side aspect ratio of 3.5 at a twenty-three degree inclination from the center-line of the mixing section.
NASA Astrophysics Data System (ADS)
Doiron, Daniel R.; Dunn, J. B.; Mitchell, W. L.; Dalton, Brian K.; Garbo, Greta M.; Warner, Jon A.
1995-05-01
The detection and quantification of the concentration of exogenous chromophores in-vivo by their fluorescence is complicated by many physical and geometrical parameters. Measurement of such signals is advantageous in determining the pharmacokinetics of photosensitizers such as those used in photodynamic therapy (PDT) or to assist in the diagnosis of tissue histological state. To overcome these difficulties a ratio based fiber optic contact fluorometer has been developed. This fluorescence detection system (FDS) uses the ratio of the fluorescence emission peak of the exogenous chromophore to that of endogenous chromophores, i.e. autofluorescence, to correct for a variety of parameters affecting the magnitude of the measured signals. By doing so it also minimizes the range of baseline measurements prior to exogenous drug injection, for various tissue types. Design of the FDS and results of its testing in animals and patients using the second generation photosensitizer Tin ethyletiopurpurin (SnET2) are presented. These results support the feasibility and usefulness of the Ratio FDS system.
A Conceptual Wing Flutter Analysis Tool for Systems Analysis and Parametric Design Study
NASA Technical Reports Server (NTRS)
Mukhopadhyay, Vivek
2003-01-01
An interactive computer program was developed for wing flutter analysis in the conceptual design stage. The objective was to estimate flutt er instability boundaries of a typical wing, when detailed structural and aerodynamic data are not available. Effects of change in key flu tter parameters can also be estimated in order to guide the conceptual design. This userfriendly software was developed using MathCad and M atlab codes. The analysis method was based on non-dimensional paramet ric plots of two primary flutter parameters, namely Regier number and Flutter number, with normalization factors based on wing torsion stiffness, sweep, mass ratio, taper ratio, aspect ratio, center of gravit y location and pitch-inertia radius of gyration. These parametric plo ts were compiled in a Chance-Vought Corporation report from database of past experiments and wind tunnel test results. An example was prese nted for conceptual flutter analysis of outer-wing of a Blended-Wing- Body aircraft.
Li, Jingsong; Zhang, Lizhu; Yu, Benli
2014-12-10
The feasibility of laser spectroscopic isotopic composition measurements of atmospheric N2O was demonstrated, although making them useful will require further improvements. The system relies on a thermoelectrically (TE) cooled continuous-wave (CW) room temperature (RT) quantum cascade laser source emitting wavelength of around 4.6μm, where strong fundamental absorption bands occur for the considered specie and its isotopomers. The analysis technique is based on wavelength modulation spectroscopy with second-harmonic detection and the combination of long-path absorption cell. Primary laboratory tests have been performed to estimate the achievable detection limits and the signal reproducibility levels in view of possible measurements of (15)N/(14)N and (18)O/(16)O isotope ratios. The experiment results showed that the site-selective (15)N/(14)N ratio can be measured with a precision of 3‰ with 90s averaging time using natural-abundance N2O sample of 12.7ppm. Copyright © 2014 Elsevier B.V. All rights reserved.
[Quantitative Analysis of Heavy Metals in Water with LIBS Based on Signal-to-Background Ratio].
Hu, Li; Zhao, Nan-jing; Liu, Wen-qing; Fang, Li; Zhang, Da-hai; Wang, Yin; Meng, De Shuo; Yu, Yang; Ma, Ming-jun
2015-07-01
There are many influence factors in the precision and accuracy of the quantitative analysis with LIBS technology. According to approximately the same characteristics trend of background spectrum and characteristic spectrum along with the change of temperature through in-depth analysis, signal-to-background ratio (S/B) measurement and regression analysis could compensate the spectral line intensity changes caused by system parameters such as laser power, spectral efficiency of receiving. Because the measurement dates were limited and nonlinear, we used support vector machine (SVM) for regression algorithm. The experimental results showed that the method could improve the stability and the accuracy of quantitative analysis of LIBS, and the relative standard deviation and average relative error of test set respectively were 4.7% and 9.5%. Data fitting method based on signal-to-background ratio(S/B) is Less susceptible to matrix elements and background spectrum etc, and provides data processing reference for real-time online LIBS quantitative analysis technology.
NASA Astrophysics Data System (ADS)
Adeloye, Adebayo J.; Soundharajan, Bankaru-Swamy
2018-06-01
When based on the zones of available water in storage, hedging has traditionally used a single hedged zone and a constant rationing ratio for constraining supply during droughts. Given the usual seasonality of reservoir inflows, it is also possible that hedging could feature multiple hedged zones and temporally varying rationing ratios but very few studies addressing this have been reported especially in relation to adaptation to projected climate change. This study developed and tested Genetic Algorithms (GA) optimised zone-based operating policies of various configurations using data for the Pong reservoir, Himachal Pradesh, India. The results show that hedging does lessen vulnerability, which dropped from ≥ 60 % without hedging to below 25 % with the single stage hedging. More complex hedging policies, e.g. two stage and/or temporally varying rationing ratios only produced marginal improvements in performance. All this shows that water hedging policies do not have to be overly complex to effectively offset reservoir vulnerability caused by water shortage resulting from e.g. projected climate change.
Su, Bin-Guang; Chen, Shao-Fen; Yeh, Shu-Hsing; Shih, Po-Wen; Lin, Ching-Chiang
2016-11-01
To cope with the government's policies to reduce medical costs, Taiwan's healthcare service providers are striving to survive by pursuing profit maximization through cost control. This article aimed to present the results of cost evaluation using activity-based costing performed in the laboratory in order to throw light on the differences between costs and the payment system of National Health Insurance (NHI). This study analyzed the data of costs and income of the clinical laboratory. Direct costs belong to their respective sections of the department. The department's shared costs, including public expenses and administrative assigned costs, were allocated to the department's respective sections. A simple regression equation was created to predict profit and loss, and evaluate the department's break-even point, fixed cost, and contribution margin ratio. In clinical chemistry and seroimmunology sections, the cost per test was lower than the NHI payment and their major laboratory tests had revenues with the profitability ratio of 8.7%, while the other sections had a higher cost per test than the NHI payment and their major tests were in deficit. The study found a simple linear regression model as follows: "Balance=-84,995+0.543×income (R2=0.544)". In order to avoid deficit, laboratories are suggested to increase test volumes, enhance laboratory test specialization, and become marginal scale. A hospital could integrate with regional medical institutions through alliances or OEM methods to increase volumes to reach marginal scale and reduce laboratory costs, enhancing the level and quality of laboratory medicine.
Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae
2017-01-01
ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887
Pottumarthy, Sudha; Sader, Helio S; Fritsche, Thomas R; Jones, Ronald N
2005-11-01
Amoxicillin/clavulanate has recently undergone formulation changes (XR and ES-600) that represent 14:1 and 16:1 ratios of amoxicillin/clavulanate. These ratios greatly differ from the 2:1 ratio used in initial formulations and in vitro susceptibility testing. The objective of this study was to determine if the reference method using a 2:1 ratio accurately reflects the susceptibility to the various clinically used amoxicillin/clavulanate formulations and their respective serum concentration ratios. A collection of 330 Haemophilus influenzae strains (300 beta-lactamase-positive and 30 beta-lactamase-negative) and 40 Moraxella catarrhalis strains (30 beta-lactamase-positive and 10 beta-lactamase-negative) were tested by the broth microdilution method against eight amoxicillin/clavulanate combinations (4:1, 5:1, 7:1, 9:1, 14:1, and 16:1 ratios; 0.5 and 2 microg/mL fixed clavulanate concentrations) and the minimum inhibitory concentration (MIC) results were compared with those obtained with the reference 2:1 ratio testing. For the beta-lactamase-negative strains of both genera, there was no demonstrable change in the MIC values obtained for all ratios analyzed (2:1 to 16:1). For the beta-lactamase-positive strains of H. influenzae and M. catarrhalis, at ratios >or=4:1 there was a shift in the central tendency of the MIC scatterplot compared with the results of testing 2:1 ratio. As a result, there was a 2-fold dilution increase in the MIC(50) and MIC(90) values, most evident for H. influenzae and BRO-1-producing M. catarrhalis strains. For beta-lactamase-positive strains of H. influenzae, the shift resulted in a change in the interpretive result for 3 isolates (1.0%) from susceptible using the reference method (2:1 ratio) to resistant (8/4 microg/mL; very major error) at the 16:1 ratio. In addition, the number of isolates with MIC values at or 1 dilution lower than the breakpoint (4/2 microg/mL) increased from 5% at 2:1 ratio to 32-33% for ratios 14:1 and 16:1. Our results indicate that, for the beta-lactamase-positive strains of H. influenzae and M. catarrhalis, the results of the amoxicillin/clavulanate reference 2:1 ratio testing do not accurately represent all the currently licensed formulations. Pharmacokinetic/pharmacodynamic (PK/PD) target attainment might be compromised when higher amoxicillin/clavulanate ratios are used clinically. With a better understanding of PK/PD parameters, reevaluation of the amoxicillin/clavulanate in vitro susceptibility testing should be considered by the standardizing authorities to reflect the licensed formulations and accurately predict clinical outcomes.
Anders, Katherine L; Cutcher, Zoe; Kleinschmidt, Immo; Donnelly, Christl A; Ferguson, Neil M; Indriani, Citra; O'Neill, Scott L; Jewell, Nicholas P; Simmons, Cameron P
2018-05-07
Cluster randomized trials are the gold standard for assessing efficacy of community-level interventions, such as vector control strategies against dengue. We describe a novel cluster randomized trial methodology with a test-negative design, which offers advantages over traditional approaches. It utilizes outcome-based sampling of patients presenting with a syndrome consistent with the disease of interest, who are subsequently classified as test-positive cases or test-negative controls on the basis of diagnostic testing. We use simulations of a cluster trial to demonstrate validity of efficacy estimates under the test-negative approach. This demonstrates that, provided study arms are balanced for both test-negative and test-positive illness at baseline and that other test-negative design assumptions are met, the efficacy estimates closely match true efficacy. We also briefly discuss analytical considerations for an odds ratio-based effect estimate arising from clustered data, and outline potential approaches to analysis. We conclude that application of the test-negative design to certain cluster randomized trials could increase their efficiency and ease of implementation.
Accuracy of diagnostic tests to detect asymptomatic bacteriuria during pregnancy.
Mignini, Luciano; Carroli, Guillermo; Abalos, Edgardo; Widmer, Mariana; Amigot, Susana; Nardin, Juan Manuel; Giordano, Daniel; Merialdi, Mario; Arciero, Graciela; Del Carmen Hourquescos, Maria
2009-02-01
A dipslide is a plastic paddle coated with agar that is attached to a plastic cap that screws onto a sterile plastic vial. Our objective was to estimate the diagnostic accuracy of the dipslide culture technique to detect asymptomatic bacteriuria during pregnancy and to evaluate the accuracy of nitrate and leucocyte esterase dipslides for screening. This was an ancillary study within a trial comparing single-day with 7-day therapy in treating asymptomatic bacteriuria. Clean-catch midstream samples were collected from pregnant women seeking routine care. Positive and negative likelihood ratios and sensitivity and specificity for the culture-based dipslide to detect and chemical dipsticks (nitrites, leukocyte esterase, or both) to screen were estimated using traditional urine culture as the "gold standard." : A total of 3,048 eligible pregnant women were screened. The prevalence of asymptomatic bacteriuria was 15%, with Escherichia coli the most prevalent organism. The likelihood ratio for detecting asymptomatic bacteriuria with a positive dipslide test was 225 (95% confidence interval [CI] 113-449), increasing the probability of asymptomatic bacteriuria to 98%; the likelihood ratio for a negative dipslide test was 0.02 (95% CI 0.01-0.05), reducing the probability of bacteriuria to less than 1%. The positive likelihood ratio of leukocyte esterase and nitrite dipsticks (when both or either one was positive) was 6.95 (95% CI 5.80-8.33), increasing the probability of bacteriuria to only 54%; the negative likelihood ratio was 0.50 (95% CI 0.45-0.57), reducing the probability to 8%. A pregnant woman with a positive dipslide test is very likely to have a definitive diagnosis of asymptomatic bacteriuria, whereas a negative result effectively rules out the presence of bacteriuria. Dipsticks that measure nitrites and leukocyte esterase have low sensitivity for use in screening for asymptomatic bacteriuria during gestation. ISRCTN, isrctn.org, 1196608 II.
NASA Astrophysics Data System (ADS)
Zhang, H.; Guan, Z. W.; Wang, Q. Y.; Liu, Y. J.; Li, J. K.
2018-05-01
The effects of microstructure and stress ratio on high cycle fatigue of nickel superalloy Nimonic 80A were investigated. The stress ratios of 0.1, 0.5 and 0.8 were chosen to perform fatigue tests in a frequency of 110 Hz. Cleavage failure was observed, and three competing failure crack initiation modes were discovered by a scanning electron microscope, which were classified as surface without facets, surface with facets and subsurface with facets. With increasing the stress ratio from 0.1 to 0.8, the occurrence probability of surface and subsurface with facets also increased and reached the maximum value at R = 0.5, meanwhile the probability of surface initiation without facets decreased. The effect of microstructure on the fatigue fracture behavior at different stress ratios was also observed and discussed. Based on the Goodman diagram, it was concluded that the fatigue strength of 50% probability of failure at R = 0.1, 0.5 and 0.8 is lower than the modified Goodman line.
Change-in-ratio estimators for populations with more than two subclasses
Udevitz, Mark S.; Pollock, Kenneth H.
1991-01-01
Change-in-ratio methods have been developed to estimate the size of populations with two or three population subclasses. Most of these methods require the often unreasonable assumption of equal sampling probabilities for individuals in all subclasses. This paper presents new models based on the weaker assumption that ratios of sampling probabilities are constant over time for populations with three or more subclasses. Estimation under these models requires that a value be assumed for one of these ratios when there are two samples. Explicit expressions are given for the maximum likelihood estimators under models for two samples with three or more subclasses and for three samples with two subclasses. A numerical method using readily available statistical software is described for obtaining the estimators and their standard errors under all of the models. Likelihood ratio tests that can be used in model selection are discussed. Emphasis is on the two-sample, three-subclass models for which Monte-Carlo simulation results and an illustrative example are presented.
Jacob, Laurent; Combes, Florence; Burger, Thomas
2018-06-18
We propose a new hypothesis test for the differential abundance of proteins in mass-spectrometry based relative quantification. An important feature of this type of high-throughput analyses is that it involves an enzymatic digestion of the sample proteins into peptides prior to identification and quantification. Due to numerous homology sequences, different proteins can lead to peptides with identical amino acid chains, so that their parent protein is ambiguous. These so-called shared peptides make the protein-level statistical analysis a challenge and are often not accounted for. In this article, we use a linear model describing peptide-protein relationships to build a likelihood ratio test of differential abundance for proteins. We show that the likelihood ratio statistic can be computed in linear time with the number of peptides. We also provide the asymptotic null distribution of a regularized version of our statistic. Experiments on both real and simulated datasets show that our procedures outperforms state-of-the-art methods. The procedures are available via the pepa.test function of the DAPAR Bioconductor R package.
Anderson, Peter; Bendtsen, Preben; Spak, Fredrik; Reynolds, Jillian; Drummond, Colin; Segura, Lidia; Keurhorst, Myrna N; Palacio-Vieira, Jorge; Wojnar, Marcin; Parkinson, Kathryn; Colom, Joan; Kłoda, Karolina; Deluca, Paolo; Baena, Begoña; Newbury-Birch, Dorothy; Wallace, Paul; Heinen, Maud; Wolstenholme, Amy; van Steenkiste, Ben; Mierzecki, Artur; Okulicz-Kozaryn, Katarzyna; Ronda, Gaby; Kaner, Eileen; Laurant, Miranda G H; Coulton, Simon; Gual, Toni
2016-11-01
To test if training and support, financial reimbursement and option of referring screen-positive patients to an internet-based method of giving advice (eBI) can increase primary health-care providers' delivery of Alcohol Use Disorders Identification Test (AUDIT)-C-based screening and advice to heavy drinkers. Cluster randomized factorial trial with 12-week implementation and measurement period. Primary health-care units (PHCU) in different locations throughout Catalonia, England, the Netherlands, Poland and Sweden. A total of 120 PHCU, 24 in each of Catalonia, England, the Netherlands, Poland and Sweden. PHCUs were randomized to one of eight groups: care as usual, training and support (TS), financial reimbursement (FR) and eBI; paired combinations of TS, FR and eBI, and all of FR, TS and eBI. The primary outcome measure was the proportion of eligible adult (age 18+ years) patients screened during a 12-week implementation period. Secondary outcome measures were proportion of screen-positive patients advised; and proportion of consulting adult patients given an intervention (screening and advice to screen-positives) during the same 12-week implementation period. During a 4-week baseline measurement period, the proportion of consulting adult patients who were screened for their alcohol consumption was 0.059 per PHCU (95% CI 0.034 to 0.084). Based on the factorial design, the ratio of the logged proportion screened during the 12-week implementation period was 1.48 (95% CI = 1.13-1.95) in PHCU that received TS versus PHCU that did not receive TS; for FR, the ratio was 2.00 (95% CI = 1.56-2.56). The option of referral to eBI did not lead to a higher proportion of patients screened. The ratio for TS plus FR was 2.34 (95% CI = 1.77-3.10), and the ratio for TS plus FR plus eBI was1.68 (95% CI = 1.11-2.53). Providing primary health-care units with training, support and financial reimbursement for delivering Alcohol Use Disorders Identification Test-C-based screening and advice to heavy drinkers increases screening for alcohol consumption. Providing primary health-care units with the option of referring screen-positive patients to an internet-based method of giving advice does not appear to increase screening for alcohol consumption. © 2016 Society for the Study of Addiction.
NASA Technical Reports Server (NTRS)
Mikkelsen, Kevin L.; McDonald, Timothy J.; Saiyed, Naseem (Technical Monitor)
2001-01-01
This report presents the results of cold flow model tests to determine the static and wind tunnel performance of several NASA AST separate flow nozzle noise reduction configurations. The tests were conducted by Aero Systems Engineering, Inc., for NASA Glenn Research Center. The tests were performed in the Channels 14 and 6 static thrust stands and the Channel 10 transonic wind tunnel at the FluiDyne Aerodynamics Laboratory in Plymouth, Minnesota. Facility checkout tests were made using standard ASME long-radius metering nozzles. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 14 static tests reported here consisted of 21 ASME nozzle facility checkout tests and 57 static model performance tests (including 22 at no charge). Fan nozzle pressure ratio varied from 1.4 to 2.0, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Channel 10 wind tunnel tests consisted of 15 tests at Mach number 0.28 and 31 tests at Mach 0.8. The sting was checked out statically in Channel 6 before the wind tunnel tests. In the Channel 6 facility, 12 ASME nozzle data points were taken and 7 model data points were taken. In the wind tunnel, fan nozzle pressure ratio varied from 1.73 to 2.8, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Test results include thrust coefficients, thrust vector angle, core and fan nozzle discharge coefficients, total pressure and temperature charging station profiles, and boat-tail static pressure distributions in the wind tunnel.
NASA Astrophysics Data System (ADS)
Westphal, T.; Nijssen, R. P. L.
2014-12-01
The effect of Constant Life Diagram (CLD) formulation on the fatigue life prediction under variable amplitude (VA) loading was investigated based on variable amplitude tests using three different load spectra representative for wind turbine loading. Next to the Wisper and WisperX spectra, the recently developed NewWisper2 spectrum was used. Based on these variable amplitude fatigue results the prediction accuracy of 4 CLD formulations is investigated. In the study a piecewise linear CLD based on the S-N curves for 9 load ratios compares favourably in terms of prediction accuracy and conservativeness. For the specific laminate used in this study Boerstra's Multislope model provides a good alternative at reduced test effort.
Three-dimensional stereophotogrammetric analysis of 50 smiles: A study of dento-facial proportions.
Ceinos, R; Lupi, L; Tellier, A; Bertrand, M F
2017-11-12
The purpose of this study was to analyze 50 smiles using 3D stereophotogrammetry (3D-spg)-based facial reconstruction, to calculate ratios involving measurements of the distances between dental and facial landmarks and to compare these ratios with the golden ratio φ (1.618). Fifty subjects with no obvious malocclusion participated in this study. For each subject, 4 photographs were acquired using the LifeViz Mini™, an absolute calibration 3D-spg system. Facial and dental landmarks (based on Farkas' definitions) were fixed, and 8 distances were measured. Four ratios were then calculated and compared with the value of 1.618. The ratio "incisal edge of the maxillary central incisor-lower border of the chin/subnasal point-incisal edge of the maxillary central incisor" (IE-Me/SN-IE) was 1.693 ± 0.190, the ratio "right endocanthion-left endocanthion/right exocanthion-right endocanthion" was 1.582 ± 0.173, the ratio "incisal edge of the maxillary central incisor-distal edge of the right canine/distal edge of the right canine-right labial commissure" was 1.670 ± 0.355, and the ratio "right labial commissure-left labial commissure/distal edge of the right canine-distal edge of the left canine" was 1.602 ± 0.136. In contrast, the vertical ratio IE-Me/SN-IE significantly differed from the golden ratio (1 sample t test, P = .009). This study revealed that the observed ratios were surprisingly close to the golden ratio. Only the vertical ratio differed from the golden ratio, whereas the horizontal ratios appear to be adequately approximated by φ. If the distances from reference points of the face to teeth within a harmonious smile exhibited recurring esthetic proportions, knowledge of such ratios would provide an additional tool for the elaboration of esthetic treatment plans. In addition, this knowledge could provide guidance when planning tooth positions and dental proportions by encouraging consideration of the global nature of the oro-facial sphere. © 2017 Wiley Periodicals, Inc.
Multielement suppressor nozzles for thrust augmentation systems.
NASA Technical Reports Server (NTRS)
Lawrence, R. L.; O'Keefe, J. V.; Tate, R. B.
1972-01-01
The noise reduction and nozzle performance characteristics of large-scale, high-aspect-ratio multielement nozzle arrays operated at low velocities were determined by test. The nozzles are selected for application to high-aspect-ratio augmentor suppressors to be used for augmentor wing airplanes. Significant improvements in noise characteristics for multielement nozzles over those of round or high-aspect-ratio slot nozzles are obtained. Elliptical noise patterns typical of slot nozzles are presented for high-aspect-ratio multielement nozzle arrays. Additional advantages are available in OASPL noise reduction from the element size and spacing. Augmentor-suppressor systems can be designed for maximum beam pattern directivity and frequency spectrum shaping advantages. Measurements of the nozzle wakes show a correlation with noise level data and frequency spectrum peaks. The noise and jet wake results are compared with existing prediction procedures based on empirical jet flow equations, Lighthill relationships, Strouhal number, and empirical shock-induced screech noise effects.
[How to screen for pheochromocytoma, primary aldosteronism and Cushing's syndrome].
Meyer, Patrick
2009-01-07
Pheochromocytoma, primary aldosteronism and Cushing's syndrome are uncommon disorders and are difficult to diagnose because laboratory tests lack validation and specificity. Despite these limitations, practice guidelines are proposed to standardize the screening procedure. The most reliable method to diagnose pheochromocytoma is the measurement of plasmatic and/or urinary metanephrines and normetanephrines depending on the pre-test probability of the disease. The approach for detection of primary aldosteronism is based on the aldosterone-renin ratio under standard conditions. Finally, three tests are available to establish the diagnosis of Cushing's syndrome: 24-h urinary free cortisol excretion, low-dose dexamethasone suppression test and the recent and promising late evening salivary cortisol.
Frequency-Based Spatial Correlation Assessments of the Ares I Subscale Acoustic Model Test Firings
NASA Technical Reports Server (NTRS)
Kenny, R. Jeremy; Houston, J.
2012-01-01
The Marshall Space Flight Center has performed a series of test firings to simulate and understand the acoustic environments generated for the Ares I liftoff profiles. Part of the instrumentation package had special sensor groups to assess the acoustic field spatial correlation features for the various test configurations. The spatial correlation characteristics were evaluated for all of the test firings, inclusive of understanding the diffuse to propagating wave amplitude ratios, the acoustic wave decays, and the incident angle of propagating waves across the sensor groups. These parameters were evaluated across the measured frequency spectra and the associated uncertainties for each parameter were estimated.
Schulze, Jenny Jakobsson; Lundmark, Jonas; Garle, Mats; Skilving, Ilona; Ekström, Lena; Rane, Anders
2008-07-01
Testosterone abuse is conventionally assessed by the urinary testosterone/epitestosterone (T/E) ratio, levels above 4.0 being considered suspicious. The large variation in testosterone glucuronide (TG) excretion and its strong association with a deletion polymorphism in the uridine diphospho-glucuronosyl transferase (UGT) 2B17 gene challenge the accuracy of the T/E ratio test. Our objective was to investigate whether genotype-based cutoff values will improve the sensitivity and specificity of the test. This was an open three-armed comparative study. A total of 55 healthy male volunteers with either two, one, or no allele [insertion/insertion, insertion/deletion, or deletion/deletion (del/del)] of the UGT2B17 gene was included in the study. A single im dose of 500 mg testosterone enanthate was administered. Urinary excretion of TG after dose and the T/E ratio during 15 d were calculated. The degree and rate of increase in the TG excretion rate were highly dependent on the UGT2B17 genotype with a 20-fold higher average maximum increase in the insertion/insertion group compared with the del/del group. Of the del/del subjects, 40% never reached the T/E ratio of 4.0 on any of the 15 d after the dose. When differentiated cutoff levels for the del/del (1.0) and the other genotypes (6.0) were applied, the sensitivity increased substantially for the del/del group, and false positives in the other genotypes were eliminated. Consideration of the genetic variation in disposition of androgens will improve the sensitivity and specificity of the testosterone doping test. This is of interest not only for combating androgen doping in sports, but also for detecting and preventing androgen abuse in society.
An intercomparison of airborne nitrogen dioxide instruments
NASA Technical Reports Server (NTRS)
Gregory, G. L.; Hoell, J. M., Jr.; Carroll, M. A.; Ridley, B. A.; Davis, D. D.; Bradshaw, J.; Rodgers, M. O.; Sandholm, S. T.; Schiff, H. I.; Torres, A. L.
1990-01-01
Results on NO2 instruments are reported from the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986. The instruments tested were (1) a two-photon LIF system using a laser for NO2-NO photolysis, (2) a chemiluminescence (CL) detector using FeSO4 for NO2-NO conversion, (3) a CL detector using an arc lamp for NO2-NO photolysis, and (4) a tunable-laser-diode multipath-absorption system. The procedures for the CITE 2 ground-based and flight tests are described in detail, and the results are presented in extensive graphs. Instrument (2) was eliminated because the FeSO4 converted atmospheric PAN to NO, resulting in spuriously high NO2 values. The remaining instruments gave readings in 30-40-percent agreement at NO2 mixing ratios of 100-200 parts per trillion by volume (pptv). At ratios below 50 pptv, the correlation among the measurements was very poor, with a tendency for system (4) to give higher values than (1) or (3).
Al-Abdullah, Ebtehal S; Al-Tuwaijri, Hanaa M; Hassan, Hanan M; Haiba, Mogedda E; Habib, Elsayed E; El-Emam, Ali A
2014-12-11
The reaction of 5-(1-adamantyl)-4-ethyl or allyl-1,2,4-triazoline-3-thione with formaldehyde solution and various 1-substituted piperazines yielded the corresponding N-Mannich bases. The newly synthesized N-Mannich bases were tested for in vitro inhibitory activities against a panel of Gram-positive and Gram-negative bacteria and the yeast-like pathogenic fungus Candida albicans. Six compounds showed potent antibacterial activity against one or more of the tested microorganisms, while two compounds exhibited moderate activity against the tested Gram-positive bacteria. None of the newly synthesized compounds were proved to possess marked activity against Candida albicans. The oral hypoglycemic activity of six compounds was determined in streptozotocin (STZ)-induced diabetic rats. Four compounds produced significant strong dose-dependent reduction of serum glucose levels, compared to gliclazide at 10 mg/kg dose level (potency ratio > 75%).
Fiber laser welding of nickel based superalloy Inconel 625
NASA Astrophysics Data System (ADS)
Janicki, Damian M.
2013-01-01
The paper describes the application of single mode high power fiber laser (HPFL) for the welding of nickel based superalloy Inconel 625. Butt joints of Inconel 625 sheets 0,8 mm thick were laser welded without an additional material. The influence of laser welding parameters on weld quality and mechanical properties of test joints was studied. The quality and mechanical properties of the joints were determined by means of tensile and bending tests, and micro hardness tests, and also metallographic examinations. The results showed that a proper selection of laser welding parameters provides non-porous, fully-penetrated welds with the aspect ratio up to 2.0. The minimum heat input required to achieve full penetration butt welded joints with no defect was found to be 6 J/mm. The yield strength and ultimate tensile strength of the joints are essentially equivalent to that for the base material.
FONSECA, Rodrigo Borges; BRANCO, Carolina Assaf; QUAGLIATTO, Paulo Sérgio; GONÇALVES, Luciano de Souza; SOARES, Carlos José; CARLO, Hugo Lemes; CORRER-SOBRINHO, Lourenço
2010-01-01
Objective To determine the influence of P/L ratio on the radiodensity and diametral tensile strength (DTS) of glass ionomer cements. Material and Methods There were 2 factors under study: P/L ratio (manufacturer's recommended P/L ratio and a 50% reduced P/L ratio), and materials (Vitro Molar, Vitro Fil, Vitro Cem conventional GICs and Vitro Fil LC, Ortho Glass LC RMGICs). Five 1-mm-thick samples of each material-P/L ratio were produced for radiodensity evaluation. Samples were x-ray exposed onto Digora phosphor plate and radiodensity was obtained using the software Digora for Windows 2.5 Rev 0. For DTS, five (4.0x8.0 mm) cylinder samples of each material were tested (0.5 mm/min). Data were subjected to one- and two-way ANOVA (5x2) followed by Tukey's HSD test, or Kruskal-Wallis and Dunn's method. For paired comparisons, t-test or Mann-Whitney test were used (a=0.05). Results There was a significant interaction (P=0.001) for the studied factors (materials vs. P/L ratio). Reduced P/L ratio resulted in significantly lower DTS for the RMGICs, but radiodensity was affected for all materials (P<0.05). Conclusions Reduced P/L ratio affected properties of the tested glass ionomer cements. RMGICs were more susceptible to lower values of DTS, but radiodensity decreased for all materials following P/L ratio reduction. PMID:21308288
NASA Astrophysics Data System (ADS)
Ulmer, S.; Mooser, A.; Nagahama, H.; Sellner, S.; Smorra, C.
2018-03-01
The BASE collaboration investigates the fundamental properties of protons and antiprotons, such as charge-to-mass ratios and magnetic moments, using advanced cryogenic Penning trap systems. In recent years, we performed the most precise measurement of the magnetic moments of both the proton and the antiproton, and conducted the most precise comparison of the proton-to-antiproton charge-to-mass ratio. In addition, we have set the most stringent constraint on directly measured antiproton lifetime, based on a unique reservoir trap technique. Our matter/antimatter comparison experiments provide stringent tests of the fundamental charge-parity-time invariance, which is one of the fundamental symmetries of the standard model of particle physics. This article reviews the recent achievements of BASE and gives an outlook to our physics programme in the ELENA era. This article is part of the Theo Murphy meeting issue `Antiproton physics in the ELENA era'.
NASA Astrophysics Data System (ADS)
Ma, Zehao; Ooi, Poh Choon; Li, Fushan; Yun, Dong Yeol; Kim, Tae Whan
2015-10-01
Nonvolatile memory (NVM) devices based on a metal-insulator-metal structure consisting of CdSe/ZnS quantum dots embedded in polymethylsilsesquioxane dielectric layers were fabricated. The current-voltage ( I- V) curves showed a bistable current behavior and the presence of hysteresis. The current-time ( I- t) curves showed that the fabricated NVM memory devices were stable up to 1 × 104 s with a distinct ON/OFF ratio of 104 and were reprogrammable when the endurance test was performed. The extrapolation of the I- t curve to 105 s with corresponding current ON/OFF ratio 1 × 105 indicated a long performance stability of the NVM devices. Schottky emission, Poole-Frenkel emission, trapped-charge limited-current and Child-Langmuir law were proposed as the dominant conduction mechanisms for the fabricated NVM devices based on the obtained I- V characteristics.
Ulmer, S; Mooser, A; Nagahama, H; Sellner, S; Smorra, C
2018-03-28
The BASE collaboration investigates the fundamental properties of protons and antiprotons, such as charge-to-mass ratios and magnetic moments, using advanced cryogenic Penning trap systems. In recent years, we performed the most precise measurement of the magnetic moments of both the proton and the antiproton, and conducted the most precise comparison of the proton-to-antiproton charge-to-mass ratio. In addition, we have set the most stringent constraint on directly measured antiproton lifetime, based on a unique reservoir trap technique. Our matter/antimatter comparison experiments provide stringent tests of the fundamental charge-parity-time invariance, which is one of the fundamental symmetries of the standard model of particle physics. This article reviews the recent achievements of BASE and gives an outlook to our physics programme in the ELENA era.This article is part of the Theo Murphy meeting issue 'Antiproton physics in the ELENA era'. © 2018 The Authors.
Mooser, A.; Nagahama, H.; Sellner, S.; Smorra, C.
2018-01-01
The BASE collaboration investigates the fundamental properties of protons and antiprotons, such as charge-to-mass ratios and magnetic moments, using advanced cryogenic Penning trap systems. In recent years, we performed the most precise measurement of the magnetic moments of both the proton and the antiproton, and conducted the most precise comparison of the proton-to-antiproton charge-to-mass ratio. In addition, we have set the most stringent constraint on directly measured antiproton lifetime, based on a unique reservoir trap technique. Our matter/antimatter comparison experiments provide stringent tests of the fundamental charge–parity–time invariance, which is one of the fundamental symmetries of the standard model of particle physics. This article reviews the recent achievements of BASE and gives an outlook to our physics programme in the ELENA era. This article is part of the Theo Murphy meeting issue ‘Antiproton physics in the ELENA era’. PMID:29459414
Pinder, John E; Rowan, David J; Smith, Jim T
2016-02-01
Data from published studies and World Wide Web sources were combined to develop a regression model to predict (137)Cs concentration ratios for saltwater fish. Predictions were developed from 1) numeric trophic levels computed primarily from random resampling of known food items and 2) K concentrations in the saltwater for 65 samplings from 41 different species from both the Atlantic and Pacific Oceans. A number of different models were initially developed and evaluated for accuracy which was assessed as the ratios of independently measured concentration ratios to those predicted by the model. In contrast to freshwater systems, were K concentrations are highly variable and are an important factor in affecting fish concentration ratios, the less variable K concentrations in saltwater were relatively unimportant in affecting concentration ratios. As a result, the simplest model, which used only trophic level as a predictor, had comparable accuracies to more complex models that also included K concentrations. A test of model accuracy involving comparisons of 56 published concentration ratios from 51 species of marine fish to those predicted by the model indicated that 52 of the predicted concentration ratios were within a factor of 2 of the observed concentration ratios. Copyright © 2015 Elsevier Ltd. All rights reserved.
Romero-Martínez, Angel; Nunes-Costa, Rui; Lila, Marisol; González-Bono, Esperanza; Moya-Albiol, Luis
2014-07-01
Intimate partner violence (IPV) perpetrators have been categorized into two groups based on their heart rate (HR) reactivity to stress following Gottman's studies. Overall, type I perpetrators tend to show autonomic underarousal, whereas type II or reactive perpetrators present a hyper-reactivity in anticipation of stress. In this study, changes in HR, pre-ejection period (PEP), vagal ratio as well as psychological state variables (anxiety and anger) in response to stress were assessed, comparing a group of type II IPV perpetrators (based on violence reports and psychological assessment; n = 17; mean age = 37) with non-violent controls (n = 17; mean age = 35) using modified version of the Trier Social Stress Test. IPV perpetrators had higher HRs and lower vagal ratios than controls, particularly during the recovery period. Moreover, the former presented shorter PEPs than controls. There were no differences between groups in the magnitude of response of the HR, PEP or vagal ratio. High baseline anxiety and anger were associated with an HR increase during the preparation time in IPV perpetrators but not in controls. These findings indicate a different cardiovascular pattern of response to psychosocial stress in IPV perpetrators, especially during recovery. Thus, they contribute to understanding the biological functioning of violence sub-types, supporting the validity of cardiovascular measures as diagnostic indicators for IPV classification.
NASA Astrophysics Data System (ADS)
Jernström, J.; Eriksson, M.; Simon, R.; Tamborini, G.; Bildstein, O.; Marquez, R. Carlos; Kehl, S. R.; Hamilton, T. F.; Ranebo, Y.; Betti, M.
2006-08-01
Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized by non-destructive analytical and microanalytical methods. Composition and elemental distribution in the particles were studied with synchrotron radiation based micro X-ray fluorescence spectrometry. Scanning electron microscope equipped with energy dispersive X-ray detector and with wavelength dispersive system as well as a secondary ion mass spectrometer were used to examine particle surfaces. Based on the elemental composition the particles were divided into two groups: particles with pure Pu matrix, and particles where the plutonium is included in Si/O-rich matrix being more heterogenously distributed. All of the particles were identified as nuclear fuel fragments of exploded weapon components. As containing plutonium with low 240Pu/ 239Pu atomic ratio, less than 0.065, which corresponds to weapons-grade plutonium or a detonation with low fission yield, the particles were identified to originate from the safety test and low-yield tests conducted in the history of Runit Island. The Si/O-rich particles contained traces of 137Cs ( 239 + 240 Pu/ 137Cs activity ratio higher than 2500), which indicated that a minor fission process occurred during the explosion. The average 241Am/ 239Pu atomic ratio in the six particles was 3.7 × 10 - 3 ± 0.2 × 10 - 3 (February 2006), which indicated that plutonium in the different particles had similar age.
Phummiphan, Itthikorn; Horpibulsuk, Suksun; Rachan, Runglawan; Arulrajah, Arul; Shen, Shui-Long; Chindaprasirt, Prinya
2018-01-05
Granulated Blast Furnace Slag (GBFS) was used as a replacement material in marginal lateritic soil (LS) while class C Fly Ash (FA) was used as a precursor for the geopolymerization process to develop a low-carbon pavement base material at ambient temperature. Unconfined Compression Strength (UCS) tests were performed to investigate the strength development of geopolymer stabilized LS/GBFS blends. Scanning Electron Microscopy and X-ray Diffraction analysis were undertaken to examine the role of the various influencing factors on UCS development. The influencing factors studied included GBFS content, Na 2 SiO 3 :NaOH ratio (NS:NH) and curing time. The 7-day soaked UCS of FA geopolymer stabilized LS/GBFS blends at various NS:NH ratios tested was found to satisfy the specifications of the Thailand national road authorities. The GBFS replacement was found to be insignificant for the improvement of the UCS of FA geopolymer stabilized LS/GBFS blends at low NS:NH ratio of 50:50. Microstructural analysis indicated the coexistence of Calcium Silicate Hydrate (CSH) and Sodium Alumino Silicate Hydrate products in FA geopolymer stabilized LS/GBFS blends. This research enables GBFS, which is traditionally considered as a waste material, to be used as a replacement and partially reactive material in FA geopolymer pavement applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Hypothesis tests for the detection of constant speed radiation moving sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir
2015-07-01
Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes amore » benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)« less
NASA Astrophysics Data System (ADS)
Wang, Fengwen
2018-05-01
This paper presents a systematic approach for designing 3D auxetic lattice materials, which exhibit constant negative Poisson's ratios over large strain intervals. A unit cell model mimicking tensile tests is established and based on the proposed model, the secant Poisson's ratio is defined as the negative ratio between the lateral and the longitudinal engineering strains. The optimization problem for designing a material unit cell with a target Poisson's ratio is formulated to minimize the average lateral engineering stresses under the prescribed deformations. Numerical results demonstrate that 3D auxetic lattice materials with constant Poisson's ratios can be achieved by the proposed optimization formulation and that two sets of material architectures are obtained by imposing different symmetry on the unit cell. Moreover, inspired by the topology-optimized material architecture, a subsequent shape optimization is proposed by parametrizing material architectures using super-ellipsoids. By designing two geometrical parameters, simple optimized material microstructures with different target Poisson's ratios are obtained. By interpolating these two parameters as polynomial functions of Poisson's ratios, material architectures for any Poisson's ratio in the interval of ν ∈ [ - 0.78 , 0.00 ] are explicitly presented. Numerical evaluations show that interpolated auxetic lattice materials exhibit constant Poisson's ratios in the target strain interval of [0.00, 0.20] and that 3D auxetic lattice material architectures with programmable Poisson's ratio are achievable.
Design, formulation and evaluation of green tea chewing gum
Aslani, Abolfazl; Ghannadi, Alireza; Khalafi, Zeinab
2014-01-01
Background: The main purpose of this study is to design, formulate and evaluate the green tea gums with a suitable taste and quality in order to produce an anti-oxidant chewing gum. Materials and Methods: Fresh green tea leaves obtained from Northern Iran for extraction. Maceration is the extraction method that is used in this study. The contents of caffeine, catechin and flavonoids of the hydro alcoholic extract were measured. Various formulations of the 120 mg green tea extract chewing gums with different sweeteners, flavoring agents and various gum bases were prepared afterward release pattern, content uniformity, organoleptic results and other properties were characterized. Results: The contents of caffeine, catechin and flavonoid of the hydro alcoholic extraction were 207.32 mg/g, 130.00 mg/g and 200.82 mg/g, respectively. Release pattern of green tea chewing gum with different gum base ratios and various sweeteners in phosphate buffer were prepared. A total of 60 persons who were 20-30 years of age, participated in our panel test for organoleptic properties such as taste, stiffness, stickiness, etc., Acceptable gum was the one with the same ratio of the used rubber bases. Cinnamon selected as the preferred taste by volunteers. Combination of aspartame, sugar and maltitol has appropriate taste. The effect of various sweetener on release pattern was negligible, on the other hand rubber bases ratio variation, changed the release pattern obviously. Conclusion: The green tea chewing gum with sugar, maltitol and aspartame sweeteners and cinnamon flavor, using the same rubber bases ratio may be a desirable antioxidant product. PMID:25161989
West Nile Virus Seroprevalence in the Greek Population in 2013: A Nationwide Cross-Sectional Survey
Hadjichristodoulou, Christos; Pournaras, Spyros; Mavrouli, Maria; Marka, Andriani; Tserkezou, Persefoni; Baka, Agoritsa; Billinis, Charalambos; Katsioulis, Antonios; Psaroulaki, Anna; Papa, Anna; Papadopoulos, Nikos; Mamuris, Zissis; Tsakris, Athanasios; Kremastinou, Jenny
2015-01-01
Cases of West Nile Virus (WNV) disease were recorded for three consecutive years in Greece following the year 2010 outbreak. A cross-sectional serologic survey was conducted to estimate the WNV seroprevalence and assess the ratio of infection to neuroinvasive disease. A stratified left-over sampling methodology was used including age and residence strata. A total of 3,962 serum samples was collected and tested for WNV Immunoglobulin G (IgG) antibodies by Enzyme–Linked Immunosorbent Assay (ELISA). All positive samples were further tested by Plaque Reduction Neutralization Test (PRNT) and WNV Immunoglobulin M (IgM) antibodies. WNV IgG antibodies were detected in 82 samples and 61 were also positive in PRNT representing a weighted seroprevalence of 2.1% (95% C.I.: 1.7–2.6) and 1.5% (95% C.I.: 1.2–2.0), respectively. Multivariable analysis showed that seroprevalence was associated with age and residence. The overall ratio of neuroinvasive disease to infected persons was estimated at 1:376 (95% C.I.: 1:421–1:338), while the elderly people had the highest ratio. This nationwide study provided valuable data regarding the epidemiology of WNV in Greece based on the fact that elderly people have higher risk of being both infected and having severe disease. PMID:26605539
ERIC Educational Resources Information Center
Kerret, Dorit; Orkibi, Hod; Ronen, Tammie
2016-01-01
This study examined a moderated mediation model with 254 Israeli junior high school students, hypothesizing that students' environmental hope would simultaneously mediate the relationship between their engagement in school-based environmental activities (green engagement) and their environmental behavior as well as their positivity ratio, but that…
Describes procedures written based on the assumption that they will be performed by analysts who are formally trained in at least the basic principles of chemical analysis and in the use of the subject technology.
A generalized system of models forecasting Central States tree growth.
Stephen R. Shifley
1987-01-01
Describes the development and testing of a system of individual tree-based growth projection models applicable to species in Indiana, Missouri, and Ohio. Annual tree basal area growth is estimated as a function of tree size, crown ratio, stand density, and site index. Models are compatible with the STEMS and TWIGS Projection System.
IRT Model Selection Methods for Dichotomous Items
ERIC Educational Resources Information Center
Kang, Taehoon; Cohen, Allan S.
2007-01-01
Fit of the model to the data is important if the benefits of item response theory (IRT) are to be obtained. In this study, the authors compared model selection results using the likelihood ratio test, two information-based criteria, and two Bayesian methods. An example illustrated the potential for inconsistency in model selection depending on…
Systems and Methods for Implementing Bulk Metallic Glass-Based Macroscale Compliant Mechanisms
NASA Technical Reports Server (NTRS)
Hofmann, Douglas C. (Inventor); Agnes, Gregory (Inventor)
2017-01-01
Systems and methods in accordance with embodiments of the invention implement bulk metallic glass-based macroscale compliant mechanisms. In one embodiment, a bulk metallic glass-based macroscale compliant mechanism includes: a flexible member that is strained during the normal operation of the compliant mechanism; where the flexible member has a thickness of 0.5 mm; where the flexible member comprises a bulk metallic glass-based material; and where the bulk metallic glass-based material can survive a fatigue test that includes 1000 cycles under a bending loading mode at an applied stress to ultimate strength ratio of 0.25.
Pham, Huy P; Sireci, Anthony N; Kim, Chong H; Schwartz, Joseph
2014-09-01
Both plasma- and recombinant activated factor VII (rFVIIa)-based algorithms can be used to correct coagulopathy in preliver transplant patients with acute liver failure requiring intracranial pressure monitor (ICPM) placement. A decision model was created to compare the cost-effectiveness of these methods. A 70-kg patient could receive either 1 round of plasma followed by coagulation testing or 2 units of plasma and 40 μg/kg rFVIIa. Intracranial pressure monitor is placed without coagulation testing after rFVIIa administration. In the plasma algorithm, the probability of ICPM placement was estimated based on expected international normalized ratio (INR) after plasma administration. Risks of rFVIIa thrombosis and transfusion reactions were also included. The model was run for patients with INRs ranging from 2 to 6 with concomitant adjustments to model parameters. The model supported the initial use of rFVIIa for ICPM placement as a cost-effective treatment when INR ≥2 (with incremental cost-effectiveness ratio of at most US$7088.02). © The Author(s) 2014.
Lee, Ji-Young; Mitchell, Jason W
2018-04-23
Couples-based HIV testing and counseling (CHTC) is currently available only for gay male couples in the United States, but other types of couples could benefit from this service. Our cross-sectional, online study collected data from 536 partnered adults to assess interest in using CHTC and associated factors. Adjusted odds ratios were calculated with ordinal logistic regression to analyze factors associated with greater interest in using CHTC. Most participants were female, White, non-Hispanic, and/or students who were dating exclusively and sexually active. Participant interest in using CHTC varied. Greater interest was associated with identifying as bisexual or questioning (adjusted odds ratio [aOR] 2.53, p < .05); having a sexual agreement (aOR 6.82, p < .001); and inconsistent or no condom use for anal sex (aOR 0.31, p < .05). These findings lend support for additional research about how best to extend and offer CHTC to a wider variety of couples. Copyright © 2018 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.
Development of remote data acquisition system based on OPC for brake test bench
NASA Astrophysics Data System (ADS)
Wang, Yiwei; Wu, Mengling; Tian, Chun; Ma, Tianhe
2017-08-01
The 1:1 train brake system test bench can be used to carry out brake-related adhesion-slid control, stability test, noise test and dynamic test. To collect data of the test bench, a data acquisition method is needed. In this paper, the remote data acquisition system of test bench is built by LabVIEW based on OPC technology. Unlike the traditional hardwire way connecting PLC acquisition module with sensors, the novel method is used to collect data and share them through the internal LAN built by Ethernet switches, which avoids the complex wiring interference in an easy, efficient and flexible way. The system has been successfully applied to the data acquisition activities of the comprehensive brake system test bench of CRRC Nanjing Puzhen Haitai Brake Equipment Co., Ltd., and the relationship test between the adhesion coefficient and the slip-ratio is realized. The speed signal, torque signal and brake disc temperature can be collected and displayed. The results show that the system is reliable, convenient, and efficient, and can meet the requirements of data acquisition.
NASA Astrophysics Data System (ADS)
van Geldern, Robert; Nowak, Martin; Zimmer, Martin; Szizybalski, Alexandra; Myrttinen, Anssi; Barth, Johannes A. C.; Jost, Hj
2016-04-01
A newly developed and commercially available isotope ratio laser spectrometer for CO2 analyses has been tested during a 10-day field monitoring campaign at the Ketzin pilot site for CO2 storage in northern Germany. The laser instrument is based on tunable laser direct absorption in the mid-infrared. The instrument recorded a continuous 10-day carbon stable isotope data set with 30 minutes resolution directly on-site in a field-based laboratory container during a tracer experiment. To test the instruments performance and accuracy the monitoring campaign was accompanied by daily CO2 sampling for laboratory analyses with isotope ratio mass spectrometry (IRMS). The carbon stable isotope ratios measured by conventional IRMS technique and by the new mid-infrared laser spectrometer agree remarkably well within 2σ analytical precision (<0.3 ‰). This proves the capability of the new mid-infrared direct absorption technique to measure high precision and accurate real-time table isotope data directly in the field. The injected CO2 tracer had a distinct δ13C value that was largely different from the reservoir background value. The laser spectroscopy data revealed a prior to this study unknown, intensive dynamic with fast changing δ13C values. The arrival pattern of the tracer suggest that the observed fluctuations were probably caused by migration along separate and distinct preferential flow paths between injection well and observation well. The new technique might contribute to a better tracing of the migration of the underground CO2 plume and help to ensure the long-term integrity of the reservoir.
Sia, Sheau Fung; Zhao, Xihai; Li, Rui; Zhang, Yu; Chong, Winston; He, Le; Chen, Yu
2016-11-01
Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss. Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss. We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.
High pressure compressor component performance report
NASA Technical Reports Server (NTRS)
Cline, S. J.; Fesler, W.; Liu, H. S.; Lovell, R. C.; Shaffer, S. J.
1983-01-01
A compressor optimization study defined a 10 stage configuration with a 22.6:1 pressure ratio, an adiabatic efficiency goal of 86.1%, and a polytropic efficiency of 90.6%; the corrected airflow is 53.5 kg/s. Subsequent component testing included three full scale tests: a six stage rig test, a 10 stage rig test, and another 10 stage rig test completed in the second quarter of 1982. Information from these tests is used to select the configuration for a core engine test and an integrated core/low spool test. The test results will also provide data base for the flight propulsion system. The results of the test series with both aerodynamic and mechanical performance of each compressor build are presented. The second 10 stage compressor adiabatic efficiency was 0.848 at a cruise operating point versus a test goal of 0.846.
Ranković, Slavica; Popović, Tamara; Martačić, Jasmina Debeljak; Petrović, Snježana; Tomić, Mirko; Ignjatović, Đurđica; Tovilović-Kovačević, Gordana; Glibetić, Maria
2017-05-19
Dietary intake influence changes in fatty acids (FA) profiles in liver which plays a central role in fatty acid metabolism, triacylglycerol synthesis and energy homeostasis. We investigated the effects of 4-weeks treatment with milk- and fish-based diet, on plasma biochemical parameters and FA composition of liver phospholipids (PL) in rats of both sexes. Adult, 4 months old, Wistar rats of both sexes, were fed with different types of diets: standard, milk-based and fish-based, during 4 weeks. Analytical characterization of different foods was done. Biochemical parameters in plasma were determined. Fatty acid composition was analyzed by gas-chromatography. Statistical significance of FA levels was tested with two-way analysis of variance (ANOVA) using the sex of animals and treatment (type of diet) as factors on logarithmic or trigonometric transformed data. Our results showed that both, milk- and fish-based diet, changed the composition and ratio of rat liver phospholipids FA, in gender-specific manner. Initially present sex differences appear to be dietary modulated. Although, applied diets changed the ratio of total saturated fatty acids (SFA), monounsaturated fatty acids (MUFA) and polyunsaturated fatty acids (PUFA), and effects were gender specific. Milk-based diet lowered SFA and elevated MUFA in males and increased PUFA in females vs. standard diet. The same diet decreased n-3, increased n-6 and n-6/n-3 ratio in males. Fish-based diet increased n-3, decreased n-6 and n-6/n-3 ratio vs. standard and milk-based diet in females. However, the ratio of individual FA in liver PL was also dietary-influenced, but with gender specific manner. While in females fish-based diet decreased AA (arachidonic acid) increased level of EPA (eicosapentaenoic acid), DPA (docosapentaenoic acid) and DHA (docosahexaenoic acid), the same diet elevated only DHA levels in males. Gender related variations in FA composition of rat liver PL were observed, and results have shown that those initial differences could be significantly modulated by the type of diet. Furthermore, the modulatory effects of milk- and fish-based diets on liver phospholipids FA profiles appeared to be sex-specific.
Conductivity and electrochemical performance of LiFePO4 slurry in the lithium slurry battery
NASA Astrophysics Data System (ADS)
Feng, Caimei; Chen, Yongchong; Liu, Dandan; Zhang, Ping
2017-06-01
Lithium slurry battery is a new type of energy storage technique which uses the slurry of solid active materials, conductive additions and liquid electrolyte as the electrode. The proportion of conductive addition and the active material has significant influence on the conductivity and electrochemical performance of the slurry electrode. In the present work, slurries with different volume ratios of LiFePO4 (LFP) and Ketjenblack (KB) were investigated by the electrochemical workstation and charge-discharge testing system (vs. Li/Li+). Results show that the conductivity of the slurry increases linearly with the addition of KB, and the measured specific capacity of the slurry reaches its theoretical value when the volume ratio of KB to LFP is around 0.2. Based on this ratio, a slurry battery with higher loading of LFP (19.1 wt.% in the slurry) was tested, and a specific capacity of 165 mAh/g at 0.2 mA/cm2 and 102 mAh/g at 5 mA/cm2 was obtained for LFP.
New non-invasive method for early detection of metabolic syndrome in the working population.
Romero-Saldaña, Manuel; Fuentes-Jiménez, Francisco J; Vaquero-Abellán, Manuel; Álvarez-Fernández, Carlos; Molina-Recio, Guillermo; López-Miranda, José
2016-12-01
We propose a new method for the early detection of metabolic syndrome in the working population, which was free of biomarkers (non-invasive) and based on anthropometric variables, and to validate it in a new working population. Prevalence studies and diagnostic test accuracy to determine the anthropometric variables associated with metabolic syndrome, as well as the screening validity of the new method proposed, were carried out between 2013 and 2015 on 636 and 550 workers, respectively. The anthropometric variables analysed were: blood pressure, body mass index, waist circumference, waist-height ratio, body fat percentage and waist-hip ratio. We performed a multivariate logistic regression analysis and obtained receiver operating curves to determine the predictive ability of the variables. The new method for the early detection of metabolic syndrome we present is based on a decision tree using chi-squared automatic interaction detection methodology. The overall prevalence of metabolic syndrome was 14.9%. The area under the curve for waist-height ratio and waist circumference was 0.91 and 0.90, respectively. The anthropometric variables associated with metabolic syndrome in the adjusted model were waist-height ratio, body mass index, blood pressure and body fat percentage. The decision tree was configured from the waist-height ratio (⩾0.55) and hypertension (blood pressure ⩾128/85 mmHg), with a sensitivity of 91.6% and a specificity of 95.7% obtained. The early detection of metabolic syndrome in a healthy population is possible through non-invasive methods, based on anthropometric indicators such as waist-height ratio and blood pressure. This method has a high degree of predictive validity and its use can be recommended in any healthcare context. © The European Society of Cardiology 2016.
Rogerson, Shane; Riches, Christopher J; Jennings, Carl; Weatherby, Robert P; Meir, Rudi A; Marshall-Gradisnik, Sonya M
2007-05-01
Tribulus terrestris is an herbal nutritional supplement that is promoted to produce large gains in strength and lean muscle mass in 5-28 days (15, 18). Although some manufacturers claim T. terrestris will not lead to a positive drug test, others have suggested that T. terrestris may increase the urinary testosterone/epitestosterone (T/E) ratio, which may place athletes at risk of a positive drug test. The purpose of the study was to determine the effect of T. terrestris on strength, fat free mass, and the urinary T/E ratio during 5 weeks of preseason training in elite rugby league players. Twenty-two Australian elite male rugby league players (mean +/- SD; age = 19.8 +/- 2.9 years; weight = 88.0 +/- 9.5 kg) were match-paired and randomly assigned in a double-blind manner to either a T. terrestris (n = 11) or placebo (n = 11) group. All subjects performed structured heavy resistance training as part of the club's preseason preparations. A T. terrestris extract (450 mg.d(-1)) or placebo capsules were consumed once daily for 5 weeks. Muscular strength, body composition, and the urinary T/E ratio were monitored prior to and after supplementation. After 5 weeks of training, strength and fat free mass increased significantly without any between-group differences. No between-group differences were noted in the urinary T/E ratio. It was concluded that T. terrestris did not produce the large gains in strength or lean muscle mass that many manufacturers claim can be experienced within 5-28 days. Furthermore, T. terrestris did not alter the urinary T/E ratio and would not place an athlete at risk of testing positive based on the World Anti-Doping Agency's urinary T/E ratio limit of 4:1.
Direct multitrait selection realizes the highest genetic response for ratio traits.
Zetouni, L; Henryon, M; Kargo, M; Lassen, J
2017-05-01
For a number of traits the phenotype considered to be the goal trait is a combination of 2 or more traits, like methane (CH) emission (CH/kg of milk). Direct selection on CH4 emission defined as a ratio is problematic, because it is uncertain whether the improvement comes from an improvement in milk yield, a decrease in CH emission or both. The goal was to test different strategies on selecting for 2 antagonistic traits- improving milk yield while decreasing methane emissions. The hypothesis was that to maximize genetic gain for a ratio trait, the best approach is to select directly for the component traits rather than using a ratio trait or a trait where 1 trait is corrected for the other as the selection criteria. Stochastic simulation was used to mimic a dairy cattle population. Three scenarios were tested, which differed in selection criteria but all selecting for increased milk yield: 1) selection based on a multitrait approach using the correlation structure between the 2 traits, 2) the ratio of methane to milk and 3) gross methane phenotypically corrected for milk. Four correlation sets were tested in all scenarios, to access robustness of the results. An average genetic gain of 66 kg of milk per yr was obtained in all scenarios, but scenario 1 had the best response for decreased methane emissions, with a genetic gain of 24.8 l/yr, while scenarios 2 and 3 had genetic gains of 27.1 and 27.3 kg/yr. The results found were persistent across correlation sets. These results confirm the hypothesis that to obtain the highest genetic gain a multitrait selection is a better approach than selecting for the ratio directly. The results are exemplified for a methane and milk scenario but can be generalized to other situations where combined traits need to be improved.
Simple and flexible SAS and SPSS programs for analyzing lag-sequential categorical data.
O'Connor, B P
1999-11-01
This paper describes simple and flexible programs for analyzing lag-sequential categorical data, using SAS and SPSS. The programs read a stream of codes and produce a variety of lag-sequential statistics, including transitional frequencies, expected transitional frequencies, transitional probabilities, adjusted residuals, z values, Yule's Q values, likelihood ratio tests of stationarity across time and homogeneity across groups or segments, transformed kappas for unidirectional dependence, bidirectional dependence, parallel and nonparallel dominance, and significance levels based on both parametric and randomization tests.
A Power Transformers Fault Diagnosis Model Based on Three DGA Ratios and PSO Optimization SVM
NASA Astrophysics Data System (ADS)
Ma, Hongzhe; Zhang, Wei; Wu, Rongrong; Yang, Chunyan
2018-03-01
In order to make up for the shortcomings of existing transformer fault diagnosis methods in dissolved gas-in-oil analysis (DGA) feature selection and parameter optimization, a transformer fault diagnosis model based on the three DGA ratios and particle swarm optimization (PSO) optimize support vector machine (SVM) is proposed. Using transforming support vector machine to the nonlinear and multi-classification SVM, establishing the particle swarm optimization to optimize the SVM multi classification model, and conducting transformer fault diagnosis combined with the cross validation principle. The fault diagnosis results show that the average accuracy of test method is better than the standard support vector machine and genetic algorithm support vector machine, and the proposed method can effectively improve the accuracy of transformer fault diagnosis is proved.
Schottky x-ray detectors based on a bulk β-Ga2O3 substrate
NASA Astrophysics Data System (ADS)
Lu, Xing; Zhou, Leidang; Chen, Liang; Ouyang, Xiaoping; Liu, Bo; Xu, Jun; Tang, Huili
2018-03-01
β-Ga2O3 Schottky barrier diodes (SBDs) have been fabricated on a bulk (100) β-Ga2O3 substrate and tested as X-ray detectors in this study. The devices exhibited good rectification properties, such as a high rectification ratio and a close-to-unity ideality factor. A high photo-to-dark current ratio exceeding 800 was achieved for X-ray detection, which was mainly attributed to the low reverse leakage current in the β-Ga2O3 SBDs. Furthermore, transient response of the β-Ga2O3 X-ray detectors was investigated, and two different detection mechanisms, photovoltaic and photoconductive, were identified. The results imply the great potential of β-Ga2O3 based devices for X-ray detection.
Heat transfer to four fineness-ratio-1.6 hexagonal prisms with various corner radii at Mach 6
NASA Technical Reports Server (NTRS)
Hunt, J. L.
1972-01-01
An investigation was conducted in the Langley 20-inch Mach 6 tunnel to define the aerodynamic heat transfer to the radioisotope fuel cask (heat source) of the SNAP-19/Pioneer power system. The shape of the SNAP-19/Pioneer heat source is that of a hexagonal prism with flat ends; the fineness ratio, based on maximum (edge to edge) diameter, is 1.61. Phase-change-paint heat-transfer data and schlieren photographs were obtained on four possible 1/2-scale entry configurations of the SNAP-19/Pioneer heat source. Tests were conducted over a wide range of attitudes and at nominal Reynolds numbers, based on the length of the unablated configuration, of 33,000; 84,000; and 2,200,000.
NASA Technical Reports Server (NTRS)
Srivastava, Prashant K.; O'Neill, Peggy; Cosh, Michael; Lang, Roger; Joseph, Alicia
2015-01-01
Vegetation water content (VWC) is an important component of microwave soil moisture retrieval algorithms. This paper aims to estimate VWC using L band active and passive radar/radiometer datasets obtained from a NASA ground-based Soil Moisture Active Passive (SMAP) simulator known as ComRAD (Combined Radar/Radiometer). Several approaches to derive vegetation information from radar and radiometer data such as HH, HV, VV, Microwave Polarization Difference Index (MPDI), HH/VV ratio, HV/(HH+VV), HV/(HH+HV+VV) and Radar Vegetation Index (RVI) are tested for VWC estimation through a generalized linear model (GLM). The overall analysis indicates that HV radar backscattering could be used for VWC content estimation with highest performance followed by HH, VV, MPDI, RVI, and other ratios.
NASA Astrophysics Data System (ADS)
Kusnadi, D.; Liwang, M. N. I.; Katu, S.; Mubin, A. H.; Halim, R.
2018-03-01
Parameters for starting antibiotic therapy such as CRP andleukocytosis are considered non-specific. Previous studies have shown the Neutrophil-Lymphocyte Count Ratio (NLCR) can serve as the basis of bacterial infection, the level of infection, and the basis of antibiotic therapy. Compared with the Procalcitonin parameter, this NLCR is rapid, an inexpensive and requires no additional sampling. To determine the correlation between The Neutrophil-LymphocyteCount Ratio to bacterial infection in HIV patients. This study was a cross-sectional observational approach to HIV subject at Wahidin Sudirohusodo and Hasanuddin University Hospital. The subjects performed routine blood, microbiology test,and blood Procalcitonin levels tests. Then performed NLCR calculations based on routine blood results. The subjects then grouped the presence or absence of bacterial infection.In 146 study subjects, there were 78 (53.4%) with bacterial infections and 68 (46.6%) without bacterial infection as controls. Subjects with bacterial infections had higher total neutrophils (84.83) compared with non-bacterial infections. Subjects with bacterial infections had total lymphocytes with an average of 8.51 lower than non-bacterial infections. Subjects with bacterial infections had higher NLCR values with an average of 12.80. The Neutrophil-Lymphocyte Count Ratio can become a marker of bacterial infection in HIV patients.
García-Ramos, Amador; Haff, G Gregory; Padial, Paulino; Feriche, Belén
2018-03-01
This study aimed to examine the reliability of different power and velocity variables during the Smith machine bench press (BP) and bench press throw (BPT) exercises. Twenty-two healthy men conducted four testing sessions after a preliminary BP one-repetition maximum (1RM) test. In a counterbalanced order, participants performed two sessions of BP in one week and two sessions of BPT in another week. Mean propulsive power, peak power, mean propulsive velocity, and peak velocity at each tenth percentile (20-70% of 1RM) were recorded by a linear transducer. The within-participants coefficient of variation (CV) was higher for the load-power relationship compared to the load-velocity relationship in both the BP (5.3% vs. 4.1%; CV ratio = 1.29) and BPT (4.7% vs. 3.4%; CV ratio = 1.38). Mean propulsive variables showed lower reliability than peak variables in both the BP (5.4% vs. 4.0%, CV ratio = 1.35) and BPT (4.8% vs. 3.3%, CV ratio = 1.45). All variables were deemed reliable, with the peak velocity demonstrating the lowest within-participants CV. Based upon these findings, the peak velocity should be chosen for the accurate assessment of BP and BPT performance.
NASA Astrophysics Data System (ADS)
Tamada, Kazuhiro; Kakiuchi, Toshifumi; Uematsu, Yoshihiko
2017-07-01
Plane bending fatigue tests are conducted to investigate fatigue crack initiation mechanisms in coarse-grained magnesium alloy, AZ31, under the stress ratios R = -1 and 0.1. The initial crystallographic structures are analyzed by an electron backscatter diffraction method. The slip or twin operation during fatigue tests is identified from the line angle analyses based on Euler angles of the grains. Under the stress ratio R = -1, relatively thick tension twin bands are formed in coarse grains. Subsequently, compression twin or secondary pyramidal slip operates within the tension twin band, resulting in the fatigue crack initiation. On the other hand, under R = 0.1 with tension-tension loading cycles, twin bands are formed on the specimen surface, but the angles of those bands do not correspond to tension twins. Misorientation analyses of c-axes in the matrix grain and twin band reveal that double twins are activated. Under R = 0.1, fatigue crack initiates along the double twin boundaries. The different manners of fatigue crack initiation at R = -1 and 0.1 are related to the asymmetricity of twining under tension and compression loadings. The fatigue strengths under different stress ratios cannot be estimated by the modified Goodman diagram due to the effect of stress ratio on crack initiation mechanisms.