Digital signal processing for the ATLAS/LUCID detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-07-01
Both the detector and the associated read-out electronics have been improved in order to cope with the LHC luminosity increase foreseen for RUN 2 and RUN 3. The new operating conditions require a careful tuning of the read-out electronics in order to optimize the signal-to-noise ratio. The new read-out electronics will allow the use of digital filtering of the photo multiplier tube signals. In this talk, we will present the first results that we obtained in the optimization of the signal-to-noise ratio. In addition, we will introduce the next steps to adapt this system to high performance read-out chains formore » low energy gamma rays. Such systems are based, for instance, on Silicon Drift Detector devices and can be used in applications at Free-Electron-Laser facilities such as the XFEL under construction at DESY. (authors)« less
Towards an Electrochemical Immunosensor System with Temperature Control for Cytokine Detection.
Metzner, Julia; Luckert, Katrin; Lemuth, Karin; Hämmerle, Martin; Moos, Ralf
2018-04-24
The cytokine interleukin-13 (IL-13) plays a major role in airway inflammation and is a target of new anti-asthmatic drugs. Hence, IL-13 determination could be interesting in assessing therapy success. Thus, in this work an electrochemical immunosensor for IL-13 was developed and integrated into a fluidic system with temperature control for read-out. Therefore, two sets of results are presented. First, the sensor was set up in sandwich format on single-walled carbon nanotube electrodes and was read out by applying the hydrogen peroxide⁻hydroquinone⁻horseradish peroxidase (HRP) system. Second, a fluidic system was built up with an integrated heating function realized by Peltier elements that allowed a temperature-controlled read-out of the immunosensor in order to study the influence of temperature on the amperometric read-out. The sensor was characterized at the temperature optimum of HRP at 30 °C and at 12 °C as a reference for lower performance. These results were compared to a measurement without temperature control. At the optimum operation temperature of 30 °C, the highest sensitivity (slope) was obtained compared to lower temperatures and a limit of detection of 5.4 ng/mL of IL-13 was calculated. Taken together, this approach is a first step towards an automated electrochemical immunosensor platform and shows the potential of a temperature-controlled read-out.
NASA Astrophysics Data System (ADS)
Li, Lihua; Ma, Jianshe; Liu, Lin; Pan, Longfa; Zhang, Jianyong; Lu, Junhui
2005-09-01
It is well known that the optical pick-up (OPU) plays a very important role in optical storage system. And the quality of OPU can be measured by the characteristics of OPU read-out spot for high density optical storage. Therefore this paper mainly designs an OPU model for high density optical storage to study the characteristics of OPU read-out spot. Firstly it analyses the optical read-out principle in OPU and contrives an optical read-out system based on the hereinbefore theory. In this step it chiefly designs the grating, splitter, collimator lens and objective lens. Secondly based on the aberrations analysis and theory involved by the splitter, the collimator lens and the optical lens, the paper uses the software CODE V to calculate the aberrations and to optimize the optical read-out system. Then the author can receive an ideal OPU read-out spot for high density optical storage and obtain the characteristics of the ideal OPU read-out spot. At the same time this paper analyses some influence factors which can directly affect the characteristics of the OPU read-out spot. Thirdly according to the up data the author practically manufactures a real optical pick-up to validate the hereinbefore designed optical read-out system. And it uses the Optical Spot Analyzer to get the image of the read-out spot. Comparing the ideal image to the actual image of the designed optical read-out system, the author finds out that the upwards analyses and design is suitable for high density storage and can be used in the actual production. And the author also receives the conclusion that the mostly influences on characteristics of OPU read-out spot for high density optical storage factors is not only the process of designing the grating, splitter, collimator lens and objective lens, but also the assembling work precision
The TOTEM T1 read out card motherboard
NASA Astrophysics Data System (ADS)
Minutoli, S.; Lo Vetere, M.; Robutti, E.
2010-12-01
This article describes the Read Out Card (ROC) motherboard, which is the main component of the T1 forward telescope front-end electronic system. The ROC main objectives are to acquire tracking data and trigger information from the detector. It performs data conversion from electrical to optical format and transfers the data streams to the next level of the system and it implements Slow Control modules which are able to receive, decode and distribute the LHC machine low jitter clock and fast command. The ROC also provides a spy mezzanine connection based on programmable FPGA and USB2.0 for laboratory and portable DAQ debugging system.
NASA Astrophysics Data System (ADS)
Bertelsen, Erin; Mayorov, Dmitriy; Folden, Charles ``Cody'', III
2015-10-01
A focal plane detection system is being developed for use with the gas-filled separator previously known as SASSYER (Small Angle Separator System at Yale for Evaporation Residues) that will be installed at the Cyclotron Institute at Texas A&M University. This system will be used to study heavy (Z >= 90) elements and features two 60×40 strip double-sided silicon detectors (DSSDs) and accompanying multiplexing read-out electronics. The DSSDs cover an area of 120×40 mm2 and are read-out by fourteen 16-channel multiplexers (Mesytec MUX-16) that perform the function of a preamplifier, shaper, and leading-edge discriminator in one unit. The multiplexers are controlled by four ``MUX drivers,'' each of which serves as a signal bus for multiple MUX-16 boards. The system allows a single 16-channel ADC to read the combined 200 strips of both DSSDs. A four peak source composed of 148Gd, 239Pu, 241Am, and 244Cm was used to characterize the performance of the system, with a preliminary energy resolution of ~ 60 keV measured for the 241Am alphas. This contribution will discuss the work performed in assembly of the test setup, optimization and performance check of the multiplexers, and the preliminary energy and position data collected with the α-source. Present address: Los Alamos National Laboratory, Los Alamos, NM 87545.
Medipix2 as a tool for proton beam characterization
NASA Astrophysics Data System (ADS)
Bisogni, M. G.; Cirrone, G. A. P.; Cuttone, G.; Del Guerra, A.; Lojacono, P.; Piliero, M. A.; Romano, F.; Rosso, V.; Sipala, V.; Stefanini, A.
2009-08-01
Proton therapy is a technique used to deliver a highly accurate and effective dose for the treatment of a variety of tumor diseases. The possibility to have an instrument able to give online information could reduce the time necessary to characterize the proton beam. To this aim we propose a detection system for online proton beam characterization based on the Medipix2 chip. Medipix2 is a detection system based on a single event counter read-out chip, bump-bonded to silicon pixel detector. The read-out chip is a matrix of 256×256 cells, 55×55 μm 2 each. To demonstrate the capabilities of Medipix2 as a proton detector, we have used a 62 MeV flux proton beam at the CATANA beam line of the LNS-INFN laboratory. The measurements performed confirmed the good imaging performances of the Medipix2 system also for the characterization of proton beams.
Tuning fork enhanced interferometric photoacoustic spectroscopy: a new method for trace gas analysis
NASA Astrophysics Data System (ADS)
Köhring, M.; Pohlkötter, A.; Willer, U.; Angelmahr, M.; Schade, W.
2011-01-01
A photoacoustic trace gas sensor based on an optical read-out method of a quartz tuning fork is shown. Instead of conventional piezoelectric signal read-out, as applied in well-known quartz-enhanced photoacoustic spectroscopy (QEPAS), an interferometric read-out method for measurement of the tuning fork's oscillation is presented. To demonstrate the potential of the optical read-out of tuning forks in photoacoustics, a comparison between the performances of a sensor with interferometric read-out and conventional QEPAS with piezoelectric read-out is reported. The two sensors show similar characteristics. The detection limit (L) for the optical read-out is determined to be L opt=(2598±84) ppm (1 σ) compared to L elec=(2579±78) ppm (1 σ) for piezoelectric read-out. In both cases the detection limit is defined by the thermal noise of the tuning fork.
Read-out electronics for DC squid magnetic measurements
Ganther, Jr., Kenneth R.; Snapp, Lowell D.
2002-01-01
Read-out electronics for DC SQUID sensor systems, the read-out electronics incorporating low Johnson noise radio-frequency flux-locked loop circuitry and digital signal processing algorithms in order to improve upon the prior art by a factor of at least ten, thereby alleviating problems caused by magnetic interference when operating DC SQUID sensor systems in magnetically unshielded environments.
Watson, T F; Weber, B; House, M G; Büch, H; Simmons, M Y
2015-10-16
We demonstrate high-fidelity electron spin read-out of a precision placed single donor in silicon via spin selective tunneling to either the D(+) or D(-) charge state of the donor. By performing read-out at the stable two electron D(0)↔D(-) charge transition we can increase the tunnel rates to a nearby single electron transistor charge sensor by nearly 2 orders of magnitude, allowing faster qubit read-out (1 ms) with minimum loss in read-out fidelity (98.4%) compared to read-out at the D(+)↔D(0) transition (99.6%). Furthermore, we show that read-out via the D(-) charge state can be used to rapidly initialize the electron spin qubit in its ground state with a fidelity of F(I)=99.8%.
NASA Astrophysics Data System (ADS)
Burse, Mahesh; Chattopadhyay, Sabyasachi; Ramaprakash, A. N.; Sinha, Sakya; Prabhudesai, Swapnil; Punnadi, Sujit; Chordia, Pravin; Kohok, Abhay
2016-07-01
As a part of a design study for the On-Instrument Low Order Wave-front Sensor (OIWFS) for the TMT Infra-Red Imaging Spectrograph (IRIS), we recently evaluated the noise performance of a detector control system consisting of IUCAA SIDECAR DRIVE ELECRONICS CONTROLLER (ISDEC), SIDECAR ASIC and HAWAII-2RG (H2RG) MUX. To understand and improve the performance of this system to serve as a near infrared wavefront sensor, we implemented new read out modes like multiple regions of interest with differential multi-accumulate readout schemes for the HAWAII-2RG (H2RG) detector. In this system, the firmware running in SIDECAR ASIC programs the detector for ROI readout, reads the detector, processes the detector output and writes the digitized data into its internal memory. ISDEC reads the digitized data from ASIC, performs the differential multi-accumulate operations and then sends the processed data to a PC over a USB interface. A special loopback board was designed and used to measure and reduce the noise from SIDECAR ASIC DC biases2. We were able to reduce the mean r.m.s read noise of this system down to 1-2 e. for any arbitrary window frame of 4x4 size at frame rates below about 200 Hz.
NASA Astrophysics Data System (ADS)
Hechenblaikner, Gerald; Flatscher, Reinhold
2013-05-01
The LISA Pathfinder mission to space employs an optical metrology system (OMS) at its core to measure the distance and attitude between two freely floating test-masses to picometer and nanorad accuracy, respectively, within the measurement band of [1 mHz, 30 mHz]. The OMS is based upon an ultra-stable optical bench with 4 heterodyne interferometers from which interference signals are read-out and processed by a digital phase-meter. Laser frequency noise, power fluctuations and optical path-length variations are suppressed to uncritical levels by dedicated control loops so that the measurement performance approaches the sensor limit imposed by the phasemeter. The system design is such that low frequency common mode noise which affects the read-out phase of all four interferometers is generally well suppressed by subtraction of a reference phase from the other interferometer signals. However, high frequency noise directly affects measurement performance and its common mode rejection depends strongly on the relative signal phases. We discuss how the data from recent test campaigns point towards high frequency phase noise as a likely performance limiting factor which explains some important performance features.
Implementation of the Timepix ASIC in the Scalable Readout System
NASA Astrophysics Data System (ADS)
Lupberger, M.; Desch, K.; Kaminski, J.
2016-09-01
We report on the development of electronics hardware, FPGA firmware and software to provide a flexible multi-chip readout of the Timepix ASIC within the framework of the Scalable Readout System (SRS). The system features FPGA-based zero-suppression and the possibility to read out up to 4×8 chips with a single Front End Concentrator (FEC). By operating several FECs in parallel, in principle an arbitrary number of chips can be read out, exploiting the scaling features of SRS. Specifically, we tested the system with a setup consisting of 160 Timepix ASICs, operated as GridPix devices in a large TPC field cage in a 1 T magnetic field at a DESY test beam facility providing an electron beam of up to 6 GeV. We discuss the design choices, the dedicated hardware components, the FPGA firmware as well as the performance of the system in the test beam.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toshito, T.; Kodama, K.; Yusa, K.
2006-05-10
We performed an experimental study of charge identification of heavy ions from helium to carbon having energy of about 290 MeV/u using an emulsion chamber. Emulsion was desensitized by means of forced fading (refreshing) to expand a dynamic range of response to highly charged particles. For the track reconstruction and charge identification, the fully automated high speed emulsion read-out system, which was originally developed for identifying minimum ionizing particles, was used without any modification. Clear track by track charge identification up to Z=6 was demonstrated. The refreshing technique has proved to be a powerful technique to expand response of emulsionmore » film to highly ionizing particles.« less
The variation of radiologists' performance over the course of a reading session
NASA Astrophysics Data System (ADS)
Elze, Markus C.; Taylor-Phillips, Sian; Mello-Thoms, Claudia; Krupinski, Elizabeth A.; Gale, Alastair G.; Clarke, Aileen
2013-03-01
The radiologist's task of reviewing many cases successively is highly repetitive and requires a high level of concentration. Fatigue effects have, for example, been shown in studies comparing performance at different times of day. However, little is known about changes in performance during an individual reading session. During a session reading an enriched case set, performance may be affected by both fatigue (i.e. decreasing performance) and training (i.e. increasing performance) effects. In this paper, we reanalyze 3 datasets from 4 studies for changes in radiologist performance during a reading session. Studies feature 8-20 radiologists reading and assessing 27-60 cases in single, uninterrupted sessions. As the studies were not designed for this analysis, study setups range from bone fractures to mammograms and randomization varies between studies. Thus, they are analyzed separately using mixed-effects models. There is some indication that, as time goes on, specificity increases (shown with p<0.05 for 2 out of 3 datasets, no significant difference for the other) while sensitivity may also increase (p<0.05 for 1 out of 3 datasets). The difficulty of `normal' (healthy / non-malignant) and `abnormal' (unhealthy / malignant) cases differs (p<0.05 for 3 out of 3 datasets) and the reader's experience may also be relevant (p<0.05 for 1 out of 3 datasets). These results suggest that careful planning of breaks and session length may help optimize reader performance. Note that the overall results are still inconclusive and a targeted study to investigate fatigue and training effects within a reading session is recommended.
Hiding the Disk and Network Latency of Out-of-Core Visualization
NASA Technical Reports Server (NTRS)
Ellsworth, David
2001-01-01
This paper describes an algorithm that improves the performance of application-controlled demand paging for out-of-core visualization by hiding the latency of reading data from both local disks or disks on remote servers. The performance improvements come from better overlapping the computation with the page reading process, and by performing multiple page reads in parallel. The paper includes measurements that show that the new multithreaded paging algorithm decreases the time needed to compute visualizations by one third when using one processor and reading data from local disk. The time needed when using one processor and reading data from remote disk decreased by two thirds. Visualization runs using data from remote disk actually ran faster than ones using data from local disk because the remote runs were able to make use of the remote server's high performance disk array.
A multiball read-out for the spherical proportional counter
NASA Astrophysics Data System (ADS)
Giganon, A.; Giomataris, I.; Gros, M.; Katsioulas, I.; Navick, X. F.; Tsiledakis, G.; Savvidis, I.; Dastgheibi-Fard, A.; Brossard, A.
2017-12-01
We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high-pressure operations. We have developed a multi-ball read-out system which consists of several balls placed at a fixed distance from the center of the spherical vessel. Such a module can tune the volume electric field at the desired value and can also provide detector segmentation with individual ball read-out. In the latter case, the large volume of the vessel becomes a spherical time projection chamber with 3D capabilities.
Performance of CATIROC: ASIC for smart readout of large photomultiplier arrays
NASA Astrophysics Data System (ADS)
Blin, S.; Callier, S.; Conforti Di Lorenzo, S.; Dulucq, F.; De La Taille, C.; Martin-Chassard, G.; Seguin-Moreau, N.
2017-03-01
CATIROC (Charge And Time Integrated Read Out Chip) is a complete read-out chip manufactured in AustriaMicroSystem (AMS) SiGe 0.35 μm technology, designed to read arrays of 16 photomultipliers (PMTs). It is an upgraded version of PARISROC2 [1] designed in 2010 in the context of the PMm2 (square meter PhotoMultiplier) project [2]. CATIROC is a SoC (System on Chip) that processes analog signals up to the digitization and sparsification to reduce the cost and cable number. The ASIC is composed of 16 independent channels that work in triggerless mode, auto-triggering on the single photo-electron. It provides a charge measurement up to 400 photoelectrons (70 pC) on two scales of 10 bits and a timing information with an accuracy of 200 ps rms. The ASIC was sent for fabrication in February 2015 and then received in September 2015. It is a good candidate for two Chinese projects (LHAASO and JUNO). The architecture and the measurements will be detailed in the paper.
Fast data acquisition with the CDF event builder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinervo, P.K.; Ragan, K.J.; Booth, A.W.
1989-02-01
The CDF (Collider Detector at Fermilab) Event Builder is an intelligent Fastbus device that performs parallel read out of a set of Fastbus slaves on multiple cable segments, formats the data, and writes the reformatted data to a Fastbus slave module. The authors review the properties of this device, and summarize its performance in the CDF data acquisition system.
Fault-tolerant reactor protection system
Gaubatz, Donald C.
1997-01-01
A reactor protection system having four divisions, with quad redundant sensors for each scram parameter providing input to four independent microprocessor-based electronic chassis. Each electronic chassis acquires the scram parameter data from its own sensor, digitizes the information, and then transmits the sensor reading to the other three electronic chassis via optical fibers. To increase system availability and reduce false scrams, the reactor protection system employs two levels of voting on a need for reactor scram. The electronic chassis perform software divisional data processing, vote 2/3 with spare based upon information from all four sensors, and send the divisional scram signals to the hardware logic panel, which performs a 2/4 division vote on whether or not to initiate a reactor scram. Each chassis makes a divisional scram decision based on data from all sensors. Each division performs independently of the others (asynchronous operation). All communications between the divisions are asynchronous. Each chassis substitutes its own spare sensor reading in the 2/3 vote if a sensor reading from one of the other chassis is faulty or missing. Therefore the presence of at least two valid sensor readings in excess of a set point is required before terminating the output to the hardware logic of a scram inhibition signal even when one of the four sensors is faulty or when one of the divisions is out of service.
Fault-tolerant reactor protection system
Gaubatz, D.C.
1997-04-15
A reactor protection system is disclosed having four divisions, with quad redundant sensors for each scram parameter providing input to four independent microprocessor-based electronic chassis. Each electronic chassis acquires the scram parameter data from its own sensor, digitizes the information, and then transmits the sensor reading to the other three electronic chassis via optical fibers. To increase system availability and reduce false scrams, the reactor protection system employs two levels of voting on a need for reactor scram. The electronic chassis perform software divisional data processing, vote 2/3 with spare based upon information from all four sensors, and send the divisional scram signals to the hardware logic panel, which performs a 2/4 division vote on whether or not to initiate a reactor scram. Each chassis makes a divisional scram decision based on data from all sensors. Each division performs independently of the others (asynchronous operation). All communications between the divisions are asynchronous. Each chassis substitutes its own spare sensor reading in the 2/3 vote if a sensor reading from one of the other chassis is faulty or missing. Therefore the presence of at least two valid sensor readings in excess of a set point is required before terminating the output to the hardware logic of a scram inhibition signal even when one of the four sensors is faulty or when one of the divisions is out of service. 16 figs.
The ATLAS tile calorimeter performance at the LHC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calkins, R.
The Tile Calorimeter (TileCal), the central section of the hadronic calorimeter of the ATLAS experiment, is a key detector component to detect hadrons, jets and taus and to measure the missing transverse energy. Due to the very good muon signal to noise ratio it assists the spectrometer in the identification and reconstruction of muons. TileCal is built of steel and scintillating tiles coupled to optical fibers and read out by photomultipliers. The calorimeter is equipped with systems that allow to monitor and to calibrate each stage of the read out system exploiting different signal sources: laser light, charge injection andmore » a radioactive source. The performance of the calorimeter has been measured and monitored using calibration data, random triggered data, cosmic muons and more importantly LHC collision events. The results presented here assess the absolute energy scale calibration precision, the energy and timing uniformity and the synchronization precision. The ensemble of the results demonstrates a very good understanding of the performance of the Tile Calorimeter that is proved to be well within the design expectations. (authors)« less
Schneider, Florian R; Mann, Alexander B; Konorov, Igor; Delso, Gaspar; Paul, Stephan; Ziegler, Sibylle I
2012-06-01
A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a (22)Na point source and reconstruct different source geometries filled with (18)F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. Copyright © 2011. Published by Elsevier GmbH.
Two-dimensional ultrahigh-density X-ray optical memory.
Bezirganyan, Hakob P; Bezirganyan, Siranush E; Bezirganyan, Hayk H; Bezirganyan, Petros H
2007-01-01
Most important aspect of nanotechnology applications in the information ultrahigh storage is the miniaturization of data carrier elements of the storage media with emphasis on the long-term stability. Proposed two-dimensional ultrahigh-density X-ray optical memory, named X-ROM, with long-term stability is an information carrier basically destined for digital data archiving. X-ROM is a semiconductor wafer, in which the high-reflectivity nanosized X-ray mirrors are embedded. Data are encoded due to certain positions of the mirrors. Ultrahigh-density data recording procedure can e.g., be performed via mask-less zone-plate-array lithography (ZPAL), spatial-phase-locked electron-beam lithography (SPLEBL), or focused ion-beam lithography (FIB). X-ROM manufactured by nanolithography technique is a write-once memory useful for terabit-scale memory applications, if the surface area of the smallest recording pits is less than 100 nm2. In this case the X-ROM surface-storage capacity of a square centimetre becomes by two orders of magnitude higher than the volumetric data density really achieved for three-dimensional optical data storage medium. Digital data read-out procedure from proposed X-ROM can e.g., be performed via glancing-angle incident X-ray micro beam (GIX) using the well-developed X-ray reflectometry technique. In presented theoretical paper the crystal-analyser operating like an image magnifier is added to the set-up of X-ROM data handling system for the purpose analogous to case of application the higher numerical aperture objective in optical data read-out system. We also propose the set-up of the X-ROM readout system based on more the one incident X-ray micro beam. Presented scheme of two-beam data handling system, which operates on two mutually perpendicular well-collimated monochromatic incident X-ray micro beams, essentially increases the reliability of the digital information read-out procedure. According the graphs of characteristic functions presented in paper, one may choose optimally the incident radiation wavelength, as well as the angle of incidence of X-ray micro beams, appropriate for proposed digital data read-out procedure.
ERIC Educational Resources Information Center
Meniado, Joel C.
2016-01-01
Metacognitive reading strategies and reading motivation play a significant role in enhancing reading comprehension. In an attempt to prove the foregoing claim in a context where there is no strong culture for reading, this study tries to find out if there is indeed a relationship between and among metacognitive reading strategies, reading…
Reliable and redundant FPGA based read-out design in the ATLAS TileCal Demonstrator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akerstedt, Henrik; Muschter, Steffen; Drake, Gary
The Tile Calorimeter at ATLAS [1] is a hadron calorimeter based on steel plates and scintillating tiles read out by PMTs. The current read-out system uses standard ADCs and custom ASICs to digitize and temporarily store the data on the detector. However, only a subset of the data is actually read out to the counting room. The on-detector electronics will be replaced around 2023. To achieve the required reliability the upgraded system will be highly redundant. Here the ASICs will be replaced with Kintex-7 FPGAs from Xilinx. This, in addition to the use of multiple 10 Gbps optical read-out links,more » will allow a full read-out of all detector data. Due to the higher radiation levels expected when the beam luminosity is increased, opportunities for repairs will be less frequent. The circuitry and firmware must therefore be designed for sufficiently high reliability using redundancy and radiation tolerant components. Within a year, a hybrid demonstrator including the new readout system will be installed in one slice of the ATLAS Tile Calorimeter. This will allow the proposed upgrade to be thoroughly evaluated well before the planned 2023 deployment in all slices, especially with regard to long term reliability. Different firmware strategies alongside with their integration in the demonstrator are presented in the context of high reliability protection against hardware malfunction and radiation induced errors.« less
Differential Effects of Paced and Unpaced Responding on delayed Serial Order Recall in Schizophrenia
Hill, S. Kristian; Griffin, Ginny B.; Houk, James C.; Sweeney, John A.
2011-01-01
Working memory for temporal order is a component of working memory that is especially dependent on striatal systems, but has not been extensively studied in schizophrenia. This study was designed to characterize serial order reproduction by adapting a spatial serial order task developed for nonhuman primate studies, while controlling for working memory load and whether responses were initiated freely (unpaced) or in an externally paced format. Clinically stable schizophrenia patients (n=27) and psychiatrically healthy individuals (n=25) were comparable on demographic variables and performance on standardized tests of immediate serial order recall (Digit Span, Spatial Span). No group differences were observed for serial order recall when read sequence reproduction was unpaced. However, schizophrenia patients exhibited significant impairments when responding was paced, regardless of sequence length or retention delay. Intact performance by schizophrenia patients during the unpaced condition indicates that prefrontal storage and striatal output systems are sufficiently intact to learn novel response sequences and hold them in working memory to perform serial order tasks. However, retention for newly learned response sequences was disrupted in schizophrenia patients by paced responding, when read-out of each element in the response sequence was externally controlled. The disruption of memory for serial order in paced read-out condition indicates a deficit in frontostriatal interaction characterized by an inability to update working memory stores and deconstruct ‘chunked’ information. PMID:21705197
A 90GHz Bolometer Camera Detector System for the Green Bank Telescope
NASA Technical Reports Server (NTRS)
Benford, Dominic J.; Allen, Christine A.; Buchanan, Ernest D.; Chen, Tina C.; Chervenak, James A.; Devlin, Mark J.; Dicker, Simon R.; Forgione, Joshua B.
2004-01-01
We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3mm) for the 100 m Green Bank Telescope (GBT) This system will provide high sensitivity (<1mjy in 1s rapid imaging (15'x15' to 250 microJy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close packed, Nyquist-sampled array of superconducting transition edge sensor bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approx. 2.10(exp 17) W/square root Hz, the TES bolometers will provide fast linear sensitive response for high performance imaging. The detectors are read out by and 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.
A 90GHz Bolometer Camera Detector System for the Green
NASA Technical Reports Server (NTRS)
Benford, Dominic J.; Allen, Christine A.; Buchanan, Ernest; Chen, Tina C.; Chervenak, James A.; Devlin, Mark J.; Dicker, Simon R.; Forgione, Joshua B.
2004-01-01
We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3 mm) for the 100m Green Bank Telescope (GBT). This system will provide high sensitivity (less than 1mJy in 1s) rapid imaging (15'x15' to 150 micron Jy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close-packed, Nyquist-sampled array of superconducting transition edge sensor (TES) bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approximately 2 x 10(exp -17) W/square root of Hz, the TES bolometers will provide fast, linear, sensitive response for high performance imaging. The detectors are read out by an 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.
Progress on the FDM Development at SRON: Toward 160 Pixels
NASA Astrophysics Data System (ADS)
den Hartog, R. H.; Bruijn, M. P.; Clenet, A.; Gottardi, L.; Hijmering, R.; Jackson, B. D.; van der Kuur, J.; van Leeuwen, B. J.; van der Linden, A. J.; van Loon, D.; Nieuwenhuizen, A.; Ridder, M.; van Winden, P.
2014-08-01
SRON is developing the electronic read-out for arrays of transition edge sensors using frequency domain multiplexing in combination with base-band feedback. The astronomical applications of this system are the read-out of soft X-ray micro-calorimeters in a potential instrument on the European X-ray mission-under-study Athena+ and far-IR bolometers for the Safari instrument on the Japanese mission SPICA. In this paper we demonstrate the simultaneous read-out of 38 bolometer pixels at a 12 aW/Hz dark NEP level. The stability of the read-out is assessed over 400 s. time spans. Although some 1/f noise is present, there are several bolometers for which 1/f-free read-out can be demonstrated.
A Reader, Inside and Out: Exploring More Ecologically Valid Understandings of Reading Motivation
ERIC Educational Resources Information Center
Neugebauer, Sabina Rak
2011-01-01
Literacy development is one of the most accurate predictors of academic success with motivation to read being a central component of that development. The documented decrease in reading motivation in adolescence is concerning for educators because of the strong association between reading motivation and reading performance. This motivational…
Latest generation of ASICs for photodetector readout
NASA Astrophysics Data System (ADS)
Seguin-Moreau, N.
2013-08-01
The OMEGA microelectronics group has designed a new generation of multichannel integrated circuits, the "ROC" family, in AustrianMicroSystem (AMS) SiGe 0.35 μm technology to read out signals from various families of photodetectors. The chip named MAROC (standing for Multi Anode ReadOut Chip) has been designed to read out MultiAnode Photomultipliers (MAPMT), Photomultiplier ARray In SiGe ReadOut Chip (PARISROC) to read out Photomultipliers (PMTs) and SiPM Integrated ReadOut Chip (SPIROC) to readout Silicon PhotoMultiplier (SiPM) detectors and which was the first ASIC to do so. The three of them fulfill the stringent requirements of the future photodetectors, in particular in terms of low noise, radiation hardness, large dynamic range, high density and high speed while keeping low power thanks to the SiGe technology. These multi-channel ASICs are real System on Chip (SoC) as they provide charge, time and photon-counting information which are digitized internally. Their complexity and versatility enable innovative frontier detectors and also cover spin off of these detectors in adjacent fields such as medical or material imaging as well as smart detectors. In this presentation, the three ASIC architectures and test results will be described to give a general panorama of the "ROC" chips.
Instrument performance of a radon measuring system with the alpha-track detection technique.
Tokonami, S; Zhuo, W; Ryuo, H; Yonehara, H; Yamada, Y; Shimo, M
2003-01-01
An instrument performance test has been carried out for a radon measuring system made in Hungary. The system measures radon using the alpha-track detection technique. It consists of three parts: the passive detector, the etching unit and the evaluation unit. A CR-39 detector is used as the radiation detector. Alpha-track reading and data analysis are carried out after chemical etching. The following subjects were examined in the present study: (1) radon sensitivity, (2) performance of etching and evaluation processes and (3) thoron sensitivity. The radon sensitivity of 6.9 x 10(-4) mm(-2) (Bq m(-3) d)(-1) was acceptable for practical application. The thoron sensitivity was estimated to be as low as 3.3 x 10(-5) mm(-2) (Bq m(-3) d)(-1) from the experimental study.
Electron trapping data storage system and applications
NASA Technical Reports Server (NTRS)
Brower, Daniel; Earman, Allen; Chaffin, M. H.
1993-01-01
The advent of digital information storage and retrieval has led to explosive growth in data transmission techniques, data compression alternatives, and the need for high capacity random access data storage. Advances in data storage technologies are limiting the utilization of digitally based systems. New storage technologies will be required which can provide higher data capacities and faster transfer rates in a more compact format. Magnetic disk/tape and current optical data storage technologies do not provide these higher performance requirements for all digital data applications. A new technology developed at the Optex Corporation out-performs all other existing data storage technologies. The Electron Trapping Optical Memory (ETOM) media is capable of storing as much as 14 gigabytes of uncompressed data on a single, double-sided 54 inch disk with a data transfer rate of up to 12 megabits per second. The disk is removable, compact, lightweight, environmentally stable, and robust. Since the Write/Read/Erase (W/R/E) processes are carried out 100 percent photonically, no heating of the recording media is required. Therefore, the storage media suffers no deleterious effects from repeated Write/Read/Erase cycling.
Frequency division multiplexed readout of TES detectors with baseband feedback
NASA Astrophysics Data System (ADS)
den Hartog, R.; Audley, M. D.; Beyer, J.; Bruijn, M. P.; de Korte, P.; Gottardi, L.; Hijmering, R.; Jackson, B.; Nieuwenhuizen, A.; van der Kuur, J.; van Leeuwen, B.-J.; Van Loon, D.
2012-09-01
SRON is developing an electronic system for the multiplexed read-out of an array of transition edge sensors (TES) by combining the techniques of frequency domain multiplexing (FDM) with base-band feedback (BBFB). The astronomical applications are the read-out of soft X-ray microcalorimeters and the far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In this paper we derive the requirements for the read-out system regarding noise and dynamic range in the context of the SAFARI instrument, and demonstrate that the current experimental prototype is capable of simultaneously locking 57 channels and complies with these requirements.
Hsu, Chia-Cheng; Chen, Hsin-Chin; Su, Yen-Ning; Huang, Kuo-Kuang; Huang, Yueh-Min
2012-10-22
A growing number of educational studies apply sensors to improve student learning in real classroom settings. However, how can sensors be integrated into classrooms to help instructors find out students' reading concentration rates and thus better increase learning effectiveness? The aim of the current study was to develop a reading concentration monitoring system for use with e-books in an intelligent classroom and to help instructors find out the students' reading concentration rates. The proposed system uses three types of sensor technologies, namely a webcam, heartbeat sensor, and blood oxygen sensor to detect the learning behaviors of students by capturing various physiological signals. An artificial bee colony (ABC) optimization approach is applied to the data gathered from these sensors to help instructors understand their students' reading concentration rates in a classroom learning environment. The results show that the use of the ABC algorithm in the proposed system can effectively obtain near-optimal solutions. The system has a user-friendly graphical interface, making it easy for instructors to clearly understand the reading status of their students.
Hsu, Chia-Cheng; Chen, Hsin-Chin; Su, Yen-Ning; Huang, Kuo-Kuang; Huang, Yueh-Min
2012-01-01
A growing number of educational studies apply sensors to improve student learning in real classroom settings. However, how can sensors be integrated into classrooms to help instructors find out students' reading concentration rates and thus better increase learning effectiveness? The aim of the current study was to develop a reading concentration monitoring system for use with e-books in an intelligent classroom and to help instructors find out the students' reading concentration rates. The proposed system uses three types of sensor technologies, namely a webcam, heartbeat sensor, and blood oxygen sensor to detect the learning behaviors of students by capturing various physiological signals. An artificial bee colony (ABC) optimization approach is applied to the data gathered from these sensors to help instructors understand their students' reading concentration rates in a classroom learning environment. The results show that the use of the ABC algorithm in the proposed system can effectively obtain near-optimal solutions. The system has a user-friendly graphical interface, making it easy for instructors to clearly understand the reading status of their students. PMID:23202042
Development of 3He LPSDs and read-out system for the SANS spectrometer at CPHS
NASA Astrophysics Data System (ADS)
Huang, T. C.; Gong, H.; Shao, B. B.; Wang, X. W.; Zhang, Y.; Pang, B. B.
2014-01-01
The Compact Pulsed Hadron Source (CPHS) is a 13-MeV proton-linac-driven neutron source under construction in Tsinghua University. Time-of-flight (TOF) small-angle neutron scattering (SANS) spectrometer is one of the first instruments to be built. It is designed to use linear position-sensitive detectors (LPSDs) of 3He gas proportional counters to cover a 1 m×1 m area. Prototypical LPSDs (Φ = 12 mm, L=1 m) have been made and read-out system is developed based on charge division. This work describes the in-house fabrication of the prototypical LPSDs and design of the read-out system including front-end electronics and data acquisition (DAQ) system. Key factors of the front-end electronics are studied and optimized with PSPICE simulation. DAQ system is designed based on VME bus architecture and FPGA Mezzanine Card (FMC) standard with high flexibility and extendibility. Preliminary experiments are carried out and the results are present and discussed.
Tracking reading: dual task costs of oral reading for young versus older adults.
Kemper, Susan; Bontempo, Daniel; Schmalzried, RaLynn; McKedy, Whitney; Tagliaferri, Bruno; Kieweg, Doug
2014-02-01
A digital pursuit rotor was used to monitor oral reading costs by time-locking tracking performance to the auditory wave form produced as young and older adults were reading out short paragraphs. Multilevel modeling was used to determine how paragraph-level predictors of length, grammatical complexity, and readability and person-level predictors such as speaker age or working memory capacity predicted reading and tracking performance. In addition, sentence-by-sentence variation in tracking performance was examined during the production of individual sentences and during the pauses before upcoming sentences. The results suggest that dual tasking has a greater impact on older adults' reading comprehension and tracking performance. At the level of individual sentences, young and older adults adopt different strategies to deal with grammatically complex and propositionally dense sentences.
JPRS Report, Science & Technology, China, High-Performance Computer Systems
1992-10-28
microprocessor array The microprocessor array in the AP85 system is com- posed of 16 completely identical array element micro - processors . Each array element...microprocessors and capable of host machine reading and writing. The memory capacity of the array element micro - processors as a whole can be expanded...transmission functions to carry out data transmission from array element micro - processor to array element microprocessor, from array element
Accelerating Demand Paging for Local and Remote Out-of-Core Visualization
NASA Technical Reports Server (NTRS)
Ellsworth, David
2001-01-01
This paper describes a new algorithm that improves the performance of application-controlled demand paging for the out-of-core visualization of data sets that are on either local disks or disks on remote servers. The performance improvements come from better overlapping the computation with the page reading process, and by performing multiple page reads in parallel. The new algorithm can be applied to many different visualization algorithms since application-controlled demand paging is not specific to any visualization algorithm. The paper includes measurements that show that the new multi-threaded paging algorithm decreases the time needed to compute visualizations by one third when using one processor and reading data from local disk. The time needed when using one processor and reading data from remote disk decreased by up to 60%. Visualization runs using data from remote disk ran about as fast as ones using data from local disk because the remote runs were able to make use of the remote server's high performance disk array.
Tracking Reading: Dual Task Costs of Oral Reading for Young versus Older Adults
ERIC Educational Resources Information Center
Kemper, Susan; Bontempo, Daniel; Schmalzried, RaLynn; McKedy, Whitney; Tagliaferri, Bruno; Kieweg, Doug
2014-01-01
A digital pursuit rotor was used to monitor oral reading costs by time-locking tracking performance to the auditory wave form produced as young and older adults were reading out short paragraphs. Multilevel modeling was used to determine how paragraph-level predictors of length, grammatical complexity, and readability and person-level predictors…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-17
... footnoted).'' c. Third column, the title, ``Table 4J.--Out-Migration Adjustment-- FY 2010 (April 1, 2010 through September 30, 2010)'' is corrected to read ``Table 4J.--(Abbreviated) Out-Migration Adjustment for... corrected to read as follows: Table 4J--(Abbreviated) Out-Migration Adjustment for Acute Care Hospitals--FY...
High-fidelity projective read-out of a solid-state spin quantum register.
Robledo, Lucio; Childress, Lilian; Bernien, Hannes; Hensen, Bas; Alkemade, Paul F A; Hanson, Ronald
2011-09-21
Initialization and read-out of coupled quantum systems are essential ingredients for the implementation of quantum algorithms. Single-shot read-out of the state of a multi-quantum-bit (multi-qubit) register would allow direct investigation of quantum correlations (entanglement), and would give access to further key resources such as quantum error correction and deterministic quantum teleportation. Although spins in solids are attractive candidates for scalable quantum information processing, their single-shot detection has been achieved only for isolated qubits. Here we demonstrate the preparation and measurement of a multi-spin quantum register in a low-temperature solid-state system by implementing resonant optical excitation techniques originally developed in atomic physics. We achieve high-fidelity read-out of the electronic spin associated with a single nitrogen-vacancy centre in diamond, and use this read-out to project up to three nearby nuclear spin qubits onto a well-defined state. Conversely, we can distinguish the state of the nuclear spins in a single shot by mapping it onto, and subsequently measuring, the electronic spin. Finally, we show compatibility with qubit control: we demonstrate initialization, coherent manipulation and single-shot read-out in a single experiment on a two-qubit register, using techniques suitable for extension to larger registers. These results pave the way for a test of Bell's inequalities on solid-state spins and the implementation of measurement-based quantum information protocols. © 2011 Macmillan Publishers Limited. All rights reserved
NASA Astrophysics Data System (ADS)
Yoon, W.; Adams, J. S.; Bandler, S. R.; Becker, D.; Bennett, D. A.; Chervenak, J. A.; Datesman, A. M.; Eckart, M. E.; Finkbeiner, F. M.; Fowler, J. W.; Gard, J. D.; Hilton, G. C.; Kelley, R. L.; Kilbourne, C. A.; Mates, J. A. B.; Miniussi, A. R.; Moseley, S. H.; Noroozian, O.; Porter, F. S.; Reintsema, C. D.; Sadleir, J. E.; Sakai, K.; Smith, S. J.; Stevenson, T. R.; Swetz, D. S.; Ullom, J. N.; Vale, L. R.; Wakeham, N. A.; Wassell, E. J.; Wollack, E. J.
2018-04-01
We performed small-scale demonstrations at GSFC of high-resolution X-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ˜ 5.9 GHz) and have quality factors of ˜ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.
Sideridis, Georgios D; Simos, Panagiotis; Mouzaki, Angeliki; Stamovlasis, Dimitrios; Georgiou, George K
2018-05-01
The purpose of the present study was to explain the moderating role of rapid automatized naming (RAN) in word reading with a cusp catastrophe model. We hypothesized that increases in RAN performance speed beyond a critical point would be associated with the disruption in word reading, consistent with a "generic shutdown" hypothesis. Participants were 587 elementary schoolchildren (Grades 2-4), among whom 87 had reading comprehension difficulties per the IQ-achievement discrepancy criterion. Data were analyzed via a cusp catastrophe model derived from the nonlinear dynamics systems theory. Results indicated that for children with reading comprehension difficulties, as naming speed falls below a critical level, the association between core reading processes (word recognition and decoding) becomes chaotic and unpredictable. However, after the significant common variance attributed to motivation, emotional, and internalizing symptoms measures from RAN scores was partialed out, its role as a bifurcation variable was no longer evident. Taken together, these findings suggest that RAN represents a salient cognitive measure that may be associated with psychoemotional processes that are, at least in part, responsible for unpredictable and chaotic word reading behavior among children with reading comprehension deficits.
The BGO Calorimeter of BGO-OD Experiment
NASA Astrophysics Data System (ADS)
Bantes, B.; Bayadilov, D.; Beck, R.; Becker, M.; Bella, A.; Bielefeldt, P.; Bieling, J.; Bleckwenn, M.; Böse, S.; Braghieri, A.; Brinkmann, K.-Th; Burdeynyi, D.; Curciarello, F.; De Leo, V.; Di Salvo, R.; Dutz, H.; Elsner, D.; Fantini, A.; Freyermuth, O.; Friedrich, S.; Frommberger, F.; Ganenko, V.; Geffers, D.; Gervino, G.; Ghio, F.; Giardina, G.; Girolami, B.; Glazier, D.; Goertz, S.; Gridnev, A.; Gutz, E.; Hammann, D.; Hannappel, J.; Hartmann, P.-F.; Hillert, W.; Ignatov, A.; Jahn, R.; Joosten, R.; Jude, T. C.; Klein, F.; Koop, K.; Krusche, B.; Lapik, A.; Levi Sandri, P.; Lopatin, I.; Mandaglio, G.; Mei, P.; Messi, F.; Messi, R.; Metag, V.; Moricciani, D.; Nanova, M.; Nedorezov, V.; Novinskiy, D.; Pedroni, P.; Romaniuk, M.; Rostomyan, T.; Rudnev, N.; Schaerf, C.; Scheluchin, G.; Schmieden, H.; Sumachev, V.; Tarakanov, V.; Vegna, V.; Walther, D.; Watts, D.; Zaunick, H.-G.; Zimmermann, T.
2015-02-01
The BGO Rugby Ball is a large solid angle electromagnetic calorimeter now installed in the ELSA Facility in Bonn. The BGO is operating in the BGO-OD experiment aiming to study meson photoproduction off proton and neutron induced by a Bremsstrahlung polarized gamma beam of energies from 0.2 to 3.2 GeV and an intensity of 5 × 107 photons per second. The scintillating material characteristics and the photomultiplier read-out make this detector particularly suited for the detection of medium energy photons and electrons with very good energy resolution. The detector has been equipped with a new electronics read-out system, consisting of 30 sampling ADC Wie-Ne-R modules which perform the off-line reconstruction of the signal start-time allowing for a good timing resolution. Performances in linearity, resolution and time response have been carefully tested at the Beam Test Facility of the INFN National Laboratories in Frascati by using a matrix of 7 BGO crystals coupled to photomultipliers and equipped with the Wie-Ne-R sampling ADCs.
Time and position sensitive single photon detector for scintillator read-out
NASA Astrophysics Data System (ADS)
Schössler, S.; Bromberger, B.; Brandis, M.; Schmidt, L. Ph H.; Tittelmeier, K.; Czasch, A.; Dangendorf, V.; Jagutzki, O.
2012-02-01
We have developed a photon counting detector system for combined neutron and γ radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy γ radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate γ energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).
Dual Task Costs of Oral Reading for Young versus Older Adults
Kemper, Susan; Bontempo, Daniel; Schmalzried, RaLynn; McKedy, Whitney; Tagliaferri, Bruno; Kieweg, Doug
2013-01-01
A digital pursuit rotor was used to monitor oral reading costs by time-locking tracking performance to the auditory wave form produced as young and older adults were reading out short paragraphs. Multilevel modeling was used to determine how paragraph-level predictors of length, grammatical complexity, and readability and person-level predictors such as speaker age or working memory capacity predicted reading and tracking performance. In addition, sentence-by-sentence variation in tracking performance was examined during the production of individual sentences and during the pauses before upcoming sentences. The results suggest that dual tasking has a greater impact on older adults’ reading comprehension and tracking performance. At the level of individual sentences, young and older adults adopt different strategies to deal with grammatically complex and propositionally dense sentences. PMID:23463405
The 160 TES bolometer read-out using FDM for SAFARI
NASA Astrophysics Data System (ADS)
Hijmering, R. A.; den Hartog, R. H.; van der Linden, A. J.; Ridder, M.; Bruijn, M. P.; van der Kuur, J.; van Leeuwen, B. J.; van Winden, P.; Jackson, B.
2014-07-01
For the read out of the Transition Edge Sensors (TES) bolometer arrays of the SAFARI instrument on the Japanese background-limited far-IR SPICA mission SRON is developing a Frequency Domain Multiplexing (FDM) read-out system. The next step after the successful demonstration of the read out of 38 TES bolometers using FDM was to demonstrate the FDM readout of the required 160 TES bolometers. Of the 160 LC filter and TES bolometer chains 151 have been connected and after cooldown 148 of the resonances could be identified. Although initial operation and locking of the pixels went smoothly the experiment revealed several complications. In this paper we describe the 160 pixel FDM set-up, show the results and discuss the issues faced during operation of the 160 pixel FDM experiment.
Müller, K; Kaldewey, T; Ripszam, R; Wildmann, J S; Bechtold, A; Bichler, M; Koblmüller, G; Abstreiter, G; Finley, J J
2013-01-01
The ability to control and exploit quantum coherence and entanglement drives research across many fields ranging from ultra-cold quantum gases to spin systems in condensed matter. Transcending different physical systems, optical approaches have proven themselves to be particularly powerful, since they profit from the established toolbox of quantum optical techniques, are state-selective, contact-less and can be extremely fast. Here, we demonstrate how a precisely timed sequence of monochromatic ultrafast (~ 2-5 ps) optical pulses, with a well defined polarisation can be used to prepare arbitrary superpositions of exciton spin states in a semiconductor quantum dot, achieve ultrafast control of the spin-wavefunction without an applied magnetic field and make high fidelity read-out the quantum state in an arbitrary basis simply by detecting a strong (~ 2-10 pA) electric current flowing in an external circuit. The results obtained show that the combined quantum state preparation, control and read-out can be performed with a near-unity (≥97%) fidelity.
NASA Astrophysics Data System (ADS)
Ratza, Viktor; Ball, Markus; Liebtrau, M.; Ketzer, Bernhard
2018-02-01
In the context of the upgrade of the LHC during the second long shutdown the interaction rate of the ALICE experiment will be increased up to 50 kHz for Pb-Pb collisions. As a consequence, a continuous read-out of the Time Projection Chamber (TPC) will be required. To keep the space-charge distortions at a manageable size, the ion backflow of the charge amplification system has to be significantly reduced. At the same time an excellent detector performance and stability of the system has to be maintained. A solution with four Gaseous Electron Multipliers (GEMs) has been adopted as baseline solution for the upgraded chambers. As an alternative approach a hybrid GEM-Micromegas detector consisting of one Micromegas (MM) and two GEMs has been investigated. The recent results of the study of the hybrid GEM-Micromegas detector will be presented and compared to measurements with four GEM foils.
AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers
NASA Technical Reports Server (NTRS)
Gottardi, L.; van de Kuur, J.; Bandler, S.; Bruijn, M.; de Korte, P.; Gao, J. R.; den Hartog, R.; Hijmering, R. A.; Hoevers, H.; Koshropanah, P.;
2011-01-01
SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.
ERIC Educational Resources Information Center
Knight, Taneka L.
2016-01-01
African American and Latino students attending Title I schools in the metropolitan Atlanta area were not reading on grade level. The majority of students are low performing readers and minimally met the reading comprehension requirements. The 2015 average 8th grade reading score for these students was 246 out of 500. This applied dissertation was…
Recurrence Quantification Analysis of Processes and Products of Discourse: A Tutorial in R
ERIC Educational Resources Information Center
Wallot, Sebastian
2017-01-01
Processes of naturalistic reading and writing are based on complex linguistic input, stretch-out over time, and rely on an integrated performance of multiple perceptual, cognitive, and motor processes. Hence, naturalistic reading and writing performance is nonstationary and exhibits fluctuations and transitions. However, instead of being just…
Innovative multi-cantilever array sensor system with MOEMS read-out
NASA Astrophysics Data System (ADS)
Ivaldi, F.; Bieniek, T.; Janus, P.; Grabiec, P.; Majstrzyk, W.; Kopiec, D.; Gotszalk, T.
2016-11-01
Cantilever based sensor system are a well-established sensor family exploited in several every-day life applications as well as in high-end research areas. The very high sensitivity of such systems and the possibility to design and functionalize the cantilevers to create purpose built and highly selective sensors have increased the interest of the scientific community and the industry in further exploiting this promising sensors type. Optical deflection detection systems for cantilever sensors provide a reliable, flexible method for reading information from cantilevers with the highest sensitivity. However the need of using multi-cantilever arrays in several fields of application such as medicine, biology or safety related areas, make the optical method less suitable due to its structural complexity. Working in the frame of a the Joint Undertaking project Lab4MEMS II our group proposes a novel and innovative approach to solve this issue, by integrating a Micro-Opto-Electro-Mechanical-System (MOEMS) with dedicated optics, electronics and software with a MOEMS micro-mirror, ultimately developed in the frame of Lab4MEMSII. In this way we are able to present a closely packed, lightweight solution combining the advantages of standard optical read-out systems with the possibility of recording multiple read-outs from large cantilever arrays quasi simultaneously.
Fidalgo, Raquel; Torrance, Mark; Arias-Gundín, Olga; Martínez-Cocó, Begoña
2014-01-01
This paper analyses performance and the process used in carrying out a common hybrid task, such as, summarizing a text, from a developmental point of view and comparing the differences between students with and without reading difficulties. 548 students typically developing and 54 students with learning difficulties for reading (grades 5 to 8, ages 11 to 14) read and summarized a text using the triple task technique and then they did a comprehension questionnaire. Attention was paid to the various activities undertaken during this task, their cognitive cost, and the organization of reading and writing activities throughout the exercise, together with performance through evaluation of the summary and the reading comprehension questionnaire. There were no significant differences in performance or strategies used for the task between students of primary and secondary education. A linear reading-writing process was mostly employed by both, with greater cost and time needed by primary students. Students with reading difficulties did not show any strategies compensating for the greater difficulty and cognitive cost that the task represents for them. The effective and strategic use of summarizing as a learning tool seems to demand a specific training for students with or without reading difficulties.
Development of an e-Learning Program for Extensive Reading
ERIC Educational Resources Information Center
Okazaki, Hironobu; Hashimoto, Shinichi; Fukuda, Eri; Nitta, Haruhiko; Kido, Kazuhiko
2012-01-01
As extensive reading becomes more commonplace in the EFL/ESL classroom, there is a rise in the number of instructors and administrators who are looking for cost-effective and space-saving methods to carry out extensive reading activities. Two extensive reading systems to respond to such concerns were developed with the support of a Grant-in-Aid…
Principles and Implementation of Reading Activities in Primary School English Class
ERIC Educational Resources Information Center
Jinxiu, Jing; Zhengping, Zeng
2016-01-01
Reading is an important skill in learning English. However, reading class is not emphasized in some primary schools in China, and there are various problems with the reading activities, which inadequately just focus on teaching of words, sentences separately from texts. This paper aims to bring out a whole system of principles in designing…
Salazar, Antonio J; Useche, Nicolás; Granja, Manuel; Morillo, Aníbal J; Bermúdez, Sonia
2017-01-01
The aim of this study was to evaluate the equivalence of brain CT interpretations performed using a diagnostic workstation and a mobile tablet computer, in a telestroke service. The ethics committee of our institution approved this retrospective study. A factorial design with 1452 interpretations was used. The assessed variables were the type of stroke classification, the presence of contraindications to the tPA administration, the presence of a hyperdense intracranial artery sign (HMCA), and the Alberta Stroke Program Early CT Score (ASPECTS) score. These variables were evaluated to determine the effect that the reading system had on their magnitudes. The achieved distribution of observed lesions using both the reading systems was not statistically different. The differences between the two reading systems to claim equivalence were 1.6% for hemorrhagic lesions, 4.5% for cases without lesion, and 5.2 for overall ischemic lesion. Equivalence was achieved at 2.1% for ASPECTS ≤ 6, 6.5% for the presence of imaging contraindication to the tPA administration, and 7.2% for the presence of HMCA. The diagnostic performance for detecting acute stroke is likely equivalent whether a tablet computer or a diagnostic workstation is used or not.
Useche, Nicolás; Granja, Manuel; Morillo, Aníbal J.; Bermúdez, Sonia
2017-01-01
Objective The aim of this study was to evaluate the equivalence of brain CT interpretations performed using a diagnostic workstation and a mobile tablet computer, in a telestroke service. Materials and Methods The ethics committee of our institution approved this retrospective study. A factorial design with 1452 interpretations was used. The assessed variables were the type of stroke classification, the presence of contraindications to the tPA administration, the presence of a hyperdense intracranial artery sign (HMCA), and the Alberta Stroke Program Early CT Score (ASPECTS) score. These variables were evaluated to determine the effect that the reading system had on their magnitudes. Results The achieved distribution of observed lesions using both the reading systems was not statistically different. The differences between the two reading systems to claim equivalence were 1.6% for hemorrhagic lesions, 4.5% for cases without lesion, and 5.2 for overall ischemic lesion. Equivalence was achieved at 2.1% for ASPECTS ≤ 6, 6.5% for the presence of imaging contraindication to the tPA administration, and 7.2% for the presence of HMCA. Conclusion The diagnostic performance for detecting acute stroke is likely equivalent whether a tablet computer or a diagnostic workstation is used or not. PMID:29250111
A position- and time-sensitive photon-counting detector with delay- line read-out
NASA Astrophysics Data System (ADS)
Jagutzki, Ottmar; Dangendorf, Volker; Lauck, Ronald; Czasch, Achim; Milnes, James
2007-05-01
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and Astronomy.
ERIC Educational Resources Information Center
Doyle, Maddie; Furnham, Adrian
2012-01-01
This study examined the effect of background music upon performance of creative and non-creative individuals on a reading comprehension task. In the presence of musical distraction and silence, 54 individuals (27 creative) carried out reading comprehension tasks in a repeated measures design. An interaction was predicted, such that musical…
Developments towards the LHCb VELO upgrade
NASA Astrophysics Data System (ADS)
Cid Vidal, Xabier
2016-09-01
The Vertex Locator (VELO) is a silicon strip detector surrounding the interaction region of the LHCb experiment. The upgrade of the VELO is planned to be installed in 2019-2020, and the current detector will be replaced by a hybrid pixel system equipped with electronics capable of reading out at a rate of 40 MHz. The new detector is designed to withstand the radiation dose expected at an integrated luminosity of 50 fb-1. The detector will be composed of silicon pixel sensors, read out by the VeloPix ASIC that is being developed based on the TimePix/MediPix family. The prototype sensors for the VELO upgrade are being irradiated in five different facilities and the post-irradiation performance is being measured with testbeams, and in the lab. These proceedings present the VELO upgrade and briefly discuss the results of the sensor testing campaign.
Evaluation of an Integrated Read-Out Layer Prototype
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abu-Ajamieh, Fayez
2011-07-01
This thesis presents evaluation results of an Integrated Read-out Layer (IRL), a proposed concept in scintillator-based calorimetry intended to meet the exceptional calorimetric requirements of the envisaged International Linear Collider (ILC). This study presents a full characterization of the prototype IRL, including exploration of relevant parameters, calibration performance, and the uniformity of response. The study represents proof of the IRL concept. Finally, proposed design enhancements are presented.
Evaluation of an Integrated Read-Out Layer Prototype
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abu-Ajamieh, Fayez; /NIU
2011-08-18
This thesis presents evaluation results of an Integrated Read-out Layer (IRL), a proposed concept in scintillator-based calorimetry intended to meet the exceptional calorimetric requirements of the envisaged International Linear Collider (ILC). This study presents a full characterization of the prototype IRL, including exploration of relevant parameters, calibration performance, and the uniformity of response. The study represents proof of the IRL concept. Finally, proposed design enhancements are presented.
Double side read-out technique for mitigation of radiation damage effects in PbWO 4 crystals
Lucchini, Marco Toliman; Auffray, E.; Benaglia, A.; ...
2016-04-18
Test beam results of a calorimetric module based on 3×3×22 cm 3 PbWO 4 crystals, identical to those used in the CMS ECAL Endcaps, read out by a pair of photodetectors coupled to the two opposite sides (front and rear) of each crystal are presented. Nine crystals with different level of induced absorption, from 0 to 20 m -1, have been tested using electrons in the 50–200 GeV energy range. Photomultiplier tubes have been chosen as photodetectors to allow for a precise measurement of highly damaged crystals. The information provided by this double side read-out configuration allows to correct formore » event-by-event fluctuations of the longitudinal development of electromagnetic showers. By strongly mitigating the effect of non-uniform light collection efficiency induced by radiation damage, the double side read-out technique significantly improves the energy resolution with respect to a single side read-out configuration. The non-linearity of the response arising in damaged crystals is also corrected by a double side read-out configuration and the response linearity of irradiated crystals is restored. In high radiation environments at future colliders, as it will be the case for detectors operating during the High Luminosity phase of the Large Hadron Collider, defects can be created inside the scintillator volume leading to a non-uniform response of the calorimetric cell. As a result, the double side read-out technique presented in this study provides a valuable way to improve the performance of calorimeters based on scintillators whose active volumes are characterized by high aspect ratio cells similar to those used in this study.« less
Double side read-out technique for mitigation of radiation damage effects in PbWO 4 crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucchini, Marco Toliman; Auffray, E.; Benaglia, A.
Test beam results of a calorimetric module based on 3×3×22 cm 3 PbWO 4 crystals, identical to those used in the CMS ECAL Endcaps, read out by a pair of photodetectors coupled to the two opposite sides (front and rear) of each crystal are presented. Nine crystals with different level of induced absorption, from 0 to 20 m -1, have been tested using electrons in the 50–200 GeV energy range. Photomultiplier tubes have been chosen as photodetectors to allow for a precise measurement of highly damaged crystals. The information provided by this double side read-out configuration allows to correct formore » event-by-event fluctuations of the longitudinal development of electromagnetic showers. By strongly mitigating the effect of non-uniform light collection efficiency induced by radiation damage, the double side read-out technique significantly improves the energy resolution with respect to a single side read-out configuration. The non-linearity of the response arising in damaged crystals is also corrected by a double side read-out configuration and the response linearity of irradiated crystals is restored. In high radiation environments at future colliders, as it will be the case for detectors operating during the High Luminosity phase of the Large Hadron Collider, defects can be created inside the scintillator volume leading to a non-uniform response of the calorimetric cell. As a result, the double side read-out technique presented in this study provides a valuable way to improve the performance of calorimeters based on scintillators whose active volumes are characterized by high aspect ratio cells similar to those used in this study.« less
Alotaibi, Abdullah Z
2007-05-01
Previous investigations have shown that reading is the most common functional problem reported by patients at a low vision practice. While there have been studies investigating effect of fonts in normal and low vision patients in English, no study has been carried out in Arabic. Additionally, there has been no investigation into the use of optimum print sizes or fonts that should be used in Arabic books and leaflets for low vision patients. Arabic sentences were read by 100 normally sighted volunteers with and without simulated cataract. Subjects read two font types (Times New Roman and Courier) in three different sizes (N8, N10 and N12). The subjects were asked to read the sentences aloud. The reading speed was calculated as number of words read divided by the time taken, while reading rate was calculated as the number of words read correctly divided by the time taken. There was an improvement in reading performance of normally sighted and simulated visually impaired subjects when the print size increased. There was no significant difference in reading performance between the two types of font used at small print size, however the reading rate improved as print size increased with Times New Roman. The results suggest that the use of N12 print in Times New Roman enhanced reading performance in normally sighted and simulated cataract subjects.
The Contribution of Morphological Knowledge to 7th Grade Students' Reading Comprehension Performance
ERIC Educational Resources Information Center
Mokhtari, Kouider; Neel, Joanna; Matatall, Abbey; Richards, Andrea
2015-01-01
In this study, we examined the role of morphology, an important yet largely understudied source of difficulty, in reading ability among 7th grade students in one junior high school in the southwestern United States. We sought to find out how much variance in reading ability is accounted for by these students' morphological knowledge, and whether…
Integrated chemiresistor array for small sensor platforms
DOE Office of Scientific and Technical Information (OSTI.GOV)
HUGHES,ROBERT C.; CASALNUOVO,STEPHEN A.; WESSENDORF,KURT O.
2000-04-13
Chemiresistors are fabricated from materials that change their electrical resistance when exposed to certain chemical species. Composites of soluble polymers with metallic particles have shown remarkable sensitivity to many volatile organic chemicals, depending on the ability of the analyte molecules to swell the polymer matrix. These sensors can be made extremely small (< 100 square microns), operate at ambient temperatures, and require almost no power to read-out. However, the chemiresistor itself is only a part of a more complex sensor system that delivers chemical information to a user who can act on the information. The authors present the design, fabricationmore » and performance of a chemiresistor array chip with four different chemiresistor materials, heaters and a temperature sensor. They also show the design and fabrication of an integrated chemiresistor array, where the electronics to read-out the chemiresistors is on the same chip with the electrodes for the chemiresistors. The circuit was designed to perform several functions to make the sensor data more useful. This low-power, integrated chemiresistor array is small enough to be deployed on a Sandia-developed microrobot platform.« less
The influence of morphological awareness on reading and writing: a systematic review.
Silva, Ainoã Athaide Macedo; Martins-Reis, Vanessa de Oliveira
2017-02-16
this study aimed to perform a systematic review of national and international studies about the relationship between morphological awareness, reading/writing, reading comprehension, and spelling. a search for national and international literature was carried out using databases Medline (via PubMed) and Portal de Periódicos da Capes (Eric, PsycINFO, LILACS, SciELO) from August to September 2015. the inclusion criteria were: studies that answered the guiding question and addressed the subject matter established by the descriptors and keywords. Studies with animals, laboratories, opinion/expert pieces, case series, case reports and review studies were excluded. the following markers were considered: type and objective of the study, the skills related to morphological awareness (reading, writing, reading comprehension and spelling), tests performed, and their main results. the search carried out in the pre-established databases with descriptors and free terms resulted in 203 articles. The search in PubMed resulted in 81 studies, and in Portal de Periódicos Capes, 122. Of the total, 154 were excluded according to the title and abstract, whereas 39 were excluded upon reading the full text. This allowed for the analysis of 10 articles. children with better scores in the morphological awareness test show better results in reading and writing across all school grades.
NASA Astrophysics Data System (ADS)
Scherbak, Aleksandr; Yulmetova, Olga
2018-05-01
A pulsed fiber laser with the wavelength 1.06 μm was used to treat titanium nitride film deposited on beryllium substrates in the air with intensities below an ablation threshold to provide oxide formation. Laser oxidation results were predicted by the chemical thermodynamic method and confirmed by experimental techniques (X-ray diffraction). The developed technology of contrast image formation is intended to be used for optoelectronic read-out system.
ERIC Educational Resources Information Center
Connor, Carol M.; Alberto, Paul A.; Compton, Donald L.; O'Connor, Rollanda E.
2014-01-01
Reading difficulties and disabilities present serious and potentially lifelong challenges. Children who do not read well are more likely to be retained a grade in school, drop out of high school, become a teen parent, or enter the juvenile justice system. Building on the extant research and seminal studies, including the National Reading Panel and…
A thermal sensor and switch based on a plasma polymer/ZnO suspended nanobelt bimorph structure
NASA Astrophysics Data System (ADS)
He, -Hau, Jr.; Singamaneni, Srikanth; Ho, Chih H.; Lin, Yen-Hsi; McConney, Michael E.; Tsukruk, Vladimir V.
2009-02-01
The combination of design and subsequent fabrication of organic/inorganic nanostructures creates an effective way to combine the favorable traits of both to achieve a desired device performance. We demonstrate a miniature electrical read-out, and a sensitive temperature sensor/switch, based on a ZnO nanobelt/plasma-polymerized benzonitrile bimorph structure. A new read-out technique based on the change in the electric current flowing through the bimorph and the contact pad has been employed, replacing the conventional cumbersome piezoresistive method or tedious optical alignment. The thermal sensor demonstrated here has great prospects for thermal switching and triggered detection owing to the relative ease in the fabrication of arrays and the direct electrical read-out.
NASA Astrophysics Data System (ADS)
Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; Chen, Ningshun; Chokheli, Davit; Davydov, Yuri; Dukes, E. Craig; Dychkant, Alexsander; Ehrlich, Ralf; Francis, Kurt; Frank, M. J.; Glagolev, Vladimir; Group, Craig; Hansen, Sten; Magill, Stephen; Oksuzian, Yuri; Pla-Dalmau, Anna; Rubinov, Paul; Simonenko, Aleksandr; Song, Enhao; Stetzler, Steven; Wu, Yongyi; Uzunyan, Sergey; Zutshi, Vishnu
2018-05-01
Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120 GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions, reflective coating mixtures, and fiber diameters. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R&D program.
Interface and protocol development for STS read-out ASIC in the CBM experiment at FAIR
NASA Astrophysics Data System (ADS)
Kasinski, Krzysztof; Zabolotny, Wojciech; Szczygiel, Robert
2014-11-01
This paper presents a proposal of a protocol for communication between the read-out integrated circuit for the STS (Silicon Tracking System) and the Data Processing Board (DPB) at CBM (Compressed Baryonic Matter) experiment at FAIR, GSI (Helmholtzzentrum fuer Schwerionenforschung GmbH) in Germany. The application background, objectives and proposed solution is presented.
Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters
NASA Technical Reports Server (NTRS)
Porst, J.-P.; Adams, J. S.; Balvin, M.; Bandler, S.; Beyer, J.; Busch, S. E.; Drung, D.; Seidel, G. M.; Smith, S. J.; Stevenson, T. R.
2012-01-01
Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution.
Paquerault, Sophie; Hardy, Paul T; Wersto, Nancy; Chen, John; Smith, Robert C
2010-09-01
The aim of this study was to explore different computerized models (the "machine") as a means to achieve optimal use of computer-aided detection (CAD) systems and to investigate whether these models can play a primary role in clinical decision making and possibly replace a clinician's subjective decision for combining his or her own assessment with that provided by a CAD system. Data previously collected from a fully crossed, multiple-reader, multiple-case observer study with and without CAD by seven observers asked to identify simulated small masses on two separate sets of 100 mammographic images (low-contrast and high-contrast sets; ie, low-contrast and high-contrast simulated masses added to random locations on normal mammograms) were used. This allowed testing two relative sensitivities between the observers and CAD. Seven models that combined detection assessments from CAD standalone, unaided read, and CAD-aided read (second read and concurrent read) were developed using the leave-one-out technique for training and testing. These models were personalized for each observer. Detection performance accuracies were analyzed using the area under a portion of the free-response receiver-operating characteristic curve (AUFC), sensitivity, and number of false-positives per image. For the low-contrast set, the use of computerized models resulted in significantly higher AUFCs compared to the unaided read mode for all readers, whereas the increased AUFCs between CAD-aided (second and concurrent reads; ie, decisions made by the readers) and unaided read modes were statistically significant for a majority, but not all, of the readers (four and five of the seven readers, respectively). For the high-contrast set, there were no significant trends in the AUFCs whether or not a model was used to combine the original reading modes. Similar results were observed when using sensitivity as the figure of merit. However, the average number of false-positives per image resulting from the computerized models remained the same as that obtained from the unaided read modes. Individual computerized models (the machine) that combine image assessments from CAD standalone, unaided read, and CAD-aided read can increase detection performance compared to the reading done by the observer. However, relative sensitivity (ie, the difference in sensitivity between CAD standalone and unaided read) was a critical factor that determined incremental improvement in decision making, whether made by the observer or using computerized models. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Puiu, A.; Becker, D.; Bennett, D.; Faverzani, M.; Ferri, E.; Fowler, J.; Gard, J.; Hays-Wehle, J.; Hilton, G.; Giachero, A.; Maino, M.; Mates, J.; Nucciotti, A.; Schmidt, D.; Swetz, D.; Ullom, J.; Vale, L.
2017-09-01
Measuring the neutrino mass is one the most compelling issue in particle physics. HOLMES is an experiment funded by the European Research Council for a direct measurement of neutrino mass. HOLMES will perform a precise measurement of the end point of the Electron Capture decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity as low as 1 eV. HOLMES, in its final configuration will deploy a 1000 pixel array of low temperature microcalorimeters: each calorimeter consists of an absorber, where the Ho atoms will be implanted, coupled to a Transition Edge Sensor thermometer. The detectors will be kept at the working temperature of ˜70 mK using a dilution refrigerator. In order to gather the required 3 × 1013 events in a three year long data taking with a pile up fraction as low as 10-4, detectors must fulfill rather high speed and resolution requirements, i.e. 10 µs rise time and 4 eV resolution. To ensure such performances with an efficient read out technique for very large detectors array kept at low temperature inside a cryostat is no trivial matter: at the moment, the most appealing read out technique applicable to large arrays of Transition Edge Sensors is rf-SQUID multiplexing. It is based on the use of rf-SQUIDs as input devices with flux ramp modulation for linearisation purposes; the rf-SQUID is then coupled to a super-conductive λ/4-wave resonator in the GHz range, and the modulated signal is finally read out using the homodyne technique.
Sound It Out! Phonics in a Comprehensive Reading System
ERIC Educational Resources Information Center
Savage, John
2006-01-01
Rather than treating phonics as an end in itself, this brief text shows how phonics fits into the overall process of a child's learning to read. It helps students understand how phonics can be integrated successfully into an effective classroom reading program. While it includes a wealth of suggestions for practical classroom applications, the…
Spectral performance of DEPFET and gateable DEPFET macropixel devices
NASA Astrophysics Data System (ADS)
Bähr, A.; Aschauer, S.; Bergbauer, B.; Hermenau, K.; Lauf, T.; Lechner, P.; Lutz, G.; Majewski, P.; Meidinger, N.; Miessner, D.; Porro, M.; Richter, R.; Schaller, G.; Schopper, F.; Stefanescu, A.; Strüder, L.; Treis, J.
2014-03-01
Future x-ray observatories, such as the proposed ATHENA+ mission, will investigate bright and rapidly evolving radiation sources. To reach the scientific goals, high speed, spatial resolving sensors with excellent spectroscopic performance are mandatory. Well suited for this task are matrices of Depleted P-channel Field Effect Transistors (DEPFETs). DEPFETs provide intrinsic signal amplification, 100 percent fill factor, charge storage capability and a low read noise. Previous studies of DEPFET matrices of 256 × 256 pixels demonstrated an excellent energy resolution of 126 eV FWHM at 5.9 keV (compared to the theoretical Fano limit 120 eV). Usually these matrices are read out on demand, using e.g. the ASTEROID ASIC. Because the DEPFET is always sensitive, charge collected during the readout, causes so called misfits, which increase the background. For low frame rates this can be neglected. However, for fast timings, as suggested for ATHENA+, this effect reduces the spectral performance. We will present measurements on DEPFET macropixel structures, read out using a semi-Gaussian shaper, which demonstrate the excellent spectroscopic performance of these devices. Furthermore we will investigate the effect of misfits on the spectral background of DEPFET devices read out on demand. These measurements show the necessity to suppress misfits when the devices are operated for fast timing modes. As will be shown this can be done using so called gateable DEPFETs. The general advantage of gateable DEPFETs at fast timings, in terms of peak-to-background ratio will be demonstrated.
Reading Visual Braille with a Retinal Prosthesis
Lauritzen, Thomas Z.; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A.; Dorn, Jessy D.; McClure, Kelly; Greenberg, Robert J.
2012-01-01
Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2–4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients. PMID:23189036
Reading visual braille with a retinal prosthesis.
Lauritzen, Thomas Z; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A; Dorn, Jessy D; McClure, Kelly; Greenberg, Robert J
2012-01-01
Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2-4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients.
Promoting Contextual Vocabulary Learning through an Adaptive Computer-Assisted EFL Reading System
ERIC Educational Resources Information Center
Wang, Y.-H.
2016-01-01
The study developed an adaptive computer-assisted reading system and investigated its effect on promoting English as a foreign language learner-readers' contextual vocabulary learning performance. Seventy Taiwanese college students were assigned to two reading groups. Participants in the customised reading group read online English texts, each of…
ERIC Educational Resources Information Center
Juliana
2018-01-01
The study compared the use of the lexical glossing and inferencing strategies that impact toward the students' reading comprehension. The objective of the study was to find out the effective strategy to use for enhancing the students' reading comprehension. The population of the study was 40 Informatics Systems students of Potensi Utama…
Qualitative and quantitative assessment of Illumina's forensic STR and SNP kits on MiSeq FGx™.
Sharma, Vishakha; Chow, Hoi Yan; Siegel, Donald; Wurmbach, Elisa
2017-01-01
Massively parallel sequencing (MPS) is a powerful tool transforming DNA analysis in multiple fields ranging from medicine, to environmental science, to evolutionary biology. In forensic applications, MPS offers the ability to significantly increase the discriminatory power of human identification as well as aid in mixture deconvolution. However, before the benefits of any new technology can be employed, a thorough evaluation of its quality, consistency, sensitivity, and specificity must be rigorously evaluated in order to gain a detailed understanding of the technique including sources of error, error rates, and other restrictions/limitations. This extensive study assessed the performance of Illumina's MiSeq FGx MPS system and ForenSeq™ kit in nine experimental runs including 314 reaction samples. In-depth data analysis evaluated the consequences of different assay conditions on test results. Variables included: sample numbers per run, targets per run, DNA input per sample, and replications. Results are presented as heat maps revealing patterns for each locus. Data analysis focused on read numbers (allele coverage), drop-outs, drop-ins, and sequence analysis. The study revealed that loci with high read numbers performed better and resulted in fewer drop-outs and well balanced heterozygous alleles. Several loci were prone to drop-outs which led to falsely typed homozygotes and therefore to genotype errors. Sequence analysis of allele drop-in typically revealed a single nucleotide change (deletion, insertion, or substitution). Analyses of sequences, no template controls, and spurious alleles suggest no contamination during library preparation, pooling, and sequencing, but indicate that sequencing or PCR errors may have occurred due to DNA polymerase infidelities. Finally, we found utilizing Illumina's FGx System at recommended conditions does not guarantee 100% outcomes for all samples tested, including the positive control, and required manual editing due to low read numbers and/or allele drop-in. These findings are important for progressing towards implementation of MPS in forensic DNA testing.
Laser marking of contrast images for optical read-out systems
NASA Astrophysics Data System (ADS)
Yulmetova, O. S.; Tumanova, M. A.
2017-11-01
In the present study the formation of contrast images that provide functionality of optical read-out systems is considered. The image contrast is determined by the difference of reflection coefficients of the beryllium surface covered with titanium nitride film (TiN) formed by physical vapor deposition and the image created on it by laser oxidation. Two ways of contrast variation are studied: by regulating both TiN reflection coefficient during vapor deposition and the reflection coefficient of the image obtained with the laser. The test results show the efficiency of the proposed approach.
Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies
NASA Technical Reports Server (NTRS)
Gottardi, L.; Blandler, S. R.; Porter, F. S.; Sadleir, J. E.; Kilbourne, C. A.; Bailey, C. N.; Finkbeiner, F. M.; Chervenak, J. A.; Adams, J. S.; Eckart, M. E.;
2012-01-01
In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.
ERIC Educational Resources Information Center
Booth, Josephine N.; Boyle, James M. E.; Kelly, Steve W.
2010-01-01
Research studies have implicated executive functions in reading difficulties (RD). But while some studies have found children with RD to be impaired on tasks of executive function other studies report unimpaired performance. A meta-analysis was carried out to determine whether these discrepant findings can be accounted for by differences in the…
Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; ...
2018-02-14
Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.
Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.
2018-05-01
Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.
Integrated Job Skills and Reading Skills Training System. Final Report.
ERIC Educational Resources Information Center
Sticht, Thomas G.; And Others
An exploratory study was conducted to evaluate the feasibility of determining the reading demands of navy jobs, using a methodology that identifies both the type of reading tasks performed on the job and the level of general reading skill required to perform that set of reading tasks. Next, a survey was made of the navy's job skills training…
High performance digital read out integrated circuit (DROIC) for infrared imaging
NASA Astrophysics Data System (ADS)
Mizuno, Genki; Olah, Robert; Oduor, Patrick; Dutta, Achyut K.; Dhar, Nibir K.
2016-05-01
Banpil Photonics has developed a high-performance Digital Read-Out Integrated Circuit (DROIC) for image sensors and camera systems targeting various military, industrial and commercial Infrared (IR) imaging applications. The on-chip digitization of the pixel output eliminates the necessity for an external analog-to-digital converter (ADC), which not only cuts costs, but also enables miniaturization of packaging to achieve SWaP-C camera systems. In addition, the DROIC offers new opportunities for greater on-chip processing intelligence that are not possible in conventional analog ROICs prevalent today. Conventional ROICs, which typically can enhance only one high performance attribute such as frame rate, power consumption or noise level, fail when simultaneously targeting the most aggressive performance requirements demanded in imaging applications today. Additionally, scaling analog readout circuits to meet such requirements leads to expensive, high-power consumption with large and complex systems that are untenable in the trend towards SWaP-C. We present the implementation of a VGA format (640x512 pixels 15μm pitch) capacitivetransimpedance amplifier (CTIA) DROIC architecture that incorporates a 12-bit ADC at the pixel level. The CTIA pixel input circuitry has two gain modes with programmable full-well capacity values of 100K e- and 500K e-. The DROIC has been developed with a system-on-chip architecture in mind, where all the timing and biasing are generated internally without requiring any critical external inputs. The chip is configurable with many parameters programmable through a serial programmable interface (SPI). It features a global shutter, low power, and high frame rates programmable from 30 up 500 frames per second in full VGA format supported through 24 LVDS outputs. This DROIC, suitable for hybridization with focal plane arrays (FPA) is ideal for high-performance uncooled camera applications ranging from near IR (NIR) and shortwave IR (SWIR) to mid-wave IR (MWIR) and long-wave IR (LWIR) spectral bands.
Low-cost, high-performance and efficiency computational photometer design
NASA Astrophysics Data System (ADS)
Siewert, Sam B.; Shihadeh, Jeries; Myers, Randall; Khandhar, Jay; Ivanov, Vitaly
2014-05-01
Researchers at the University of Alaska Anchorage and University of Colorado Boulder have built a low cost high performance and efficiency drop-in-place Computational Photometer (CP) to test in field applications ranging from port security and safety monitoring to environmental compliance monitoring and surveying. The CP integrates off-the-shelf visible spectrum cameras with near to long wavelength infrared detectors and high resolution digital snapshots in a single device. The proof of concept combines three or more detectors into a single multichannel imaging system that can time correlate read-out, capture, and image process all of the channels concurrently with high performance and energy efficiency. The dual-channel continuous read-out is combined with a third high definition digital snapshot capability and has been designed using an FPGA (Field Programmable Gate Array) to capture, decimate, down-convert, re-encode, and transform images from two standard definition CCD (Charge Coupled Device) cameras at 30Hz. The continuous stereo vision can be time correlated to megapixel high definition snapshots. This proof of concept has been fabricated as a fourlayer PCB (Printed Circuit Board) suitable for use in education and research for low cost high efficiency field monitoring applications that need multispectral and three dimensional imaging capabilities. Initial testing is in progress and includes field testing in ports, potential test flights in un-manned aerial systems, and future planned missions to image harsh environments in the arctic including volcanic plumes, ice formation, and arctic marine life.
e2v CMOS and CCD sensors and systems for astronomy
NASA Astrophysics Data System (ADS)
Jorden, P. R.; Jerram, P. A.; Fryer, M.; Stefanov, K. D.
2017-07-01
e2v designs and manufactures a wide range of sensors for space and astronomy applications. This includes high performance CCDs for X-ray, visible and near-IR wavelengths. In this paper we illustrate the maturity of CMOS capability for these applications; examples are presented together with performance data. The majority of e2v sensors for these applications are back-thinned for highest spectral response and designed for very low read-out noise; the combination delivers high signal to noise ratio in association with a variety of formats and package designs. The growing e2v capability in delivery of sub-systems and cryogenic cameras is illustrated—including the 1.2 Giga-pixel J-PAS camera system.
Readout electronics for CBM-TOF super module quality evaluation based on 10 Gbps ethernet
NASA Astrophysics Data System (ADS)
Jiang, D.; Cao, P.; Huang, X.; Zheng, J.; Wang, Q.; Li, B.; Li, J.; Liu, S.; An, Q.
2017-07-01
The Compressed Baryonic Matter-Time of Flight (CBM-TOF) wall uses high performance of Multi-gap Resistive Plate Chambers (MRPC) assembled in super modules to identify charged particles with high channel density and high measurement precision at high event rate. Electronics meet the challenge for reading data out from a super module at high speed of about 6 Gbps in real time. In this paper, the readout electronics for CBM-TOF super module quality evaluation is proposed based on 10 Gigabit Ethernet. The digitized TOF data from one super module will be concentrated at the front-end electronics residing on the side of the super module and transmitted to an extreme speed readout module (XSRM) housed in the backend crate through the PCI Express (PCIe) protocol via optic channels. Eventually, the XSRM transmits data to the data acquisition (DAQ) system through four 10 Gbps Ethernet ports in real time. This readout structure has advantages of high performance and expansibility. Furthermore, it is easy to operate. Test results on the prototype show that the overall data readout performance for each XSRM can reach up to 28.8 Gbps, which means XSRM can meet the requirement of reading data out from 4 super modules with 1280 channels in real time.
NASA Astrophysics Data System (ADS)
Onuma, Takashi; Otani, Yukitoshi
2014-03-01
A two-dimensional birefringence distribution measurement system with a sampling rate of 1.3 MHz is proposed. A polarization image sensor is developed as core device of the system. It is composed of a pixelated polarizer array made from photonic crystal and a parallel read out circuit with a multi-channel analog to digital converter specialized for two-dimensional polarization detection. By applying phase shifting algorism with circularly-polarized incident light, birefringence phase difference and azimuthal angle can be measured. The performance of the system is demonstrated experimentally by measuring actual birefringence distribution and polarization device such as Babinet-Soleil compensator.
Tachibana, Atsumichi; Noah, J Adam; Bronner, Shaw; Ono, Yumie; Hirano, Yoshiyuki; Niwa, Masami; Watanabe, Kazuko; Onozuka, Minoru
2012-05-28
The Kana Pick-out Test (KPT), which uses Kana or Japanese symbols that represent syllables, requires parallel processing of discrete (pick-out) and continuous (reading) dual tasks. As a dual task, the KPT is thought to test working memory and executive function, particularly in the prefrontal cortex (PFC), and is widely used in Japan as a clinical screen for dementia. Nevertheless, there has been little neurological investigation into PFC activity during this test. We used functional magnetic resonance imaging (fMRI) to evaluate changes in the blood oxygenation level-dependent (BOLD) signal in young healthy adults during performance of a computerized KPT dual task (comprised of reading comprehension and picking out vowels) and compared it to its single task components (reading or vowel pick-out alone). Behavioral performance of the KPT degraded compared to its single task components. Performance of the KPT markedly increased BOLD signal intensity in the PFC, and also activated sensorimotor, parietal association, and visual cortex areas. In conjunction analyses, bilateral BOLD signal in the dorsolateral PFC (Brodmann's areas 45, 46) was present only in the KPT. Our results support the central bottleneck theory and suggest that the dorsolateral PFC is an important mediator of neural activity for both short-term storage and executive processes. Quantitative evaluation of the KPT with fMRI in healthy adults is the first step towards understanding the effects of aging or cognitive impairment on KPT performance.
Feasibility of ultra-wideband SAW RFID tags meeting FCC rules.
Härmä, Sanna; Plessky, Victor P; Li, Xianyi; Hartogh, Paul
2009-04-01
We discuss the feasibility of surface acoustic wave (SAW) radio-frequency identification (RFID) tags that rely on ultra-wideband (UWB) technology. We propose a design of a UWB SAW tag, carry out numerical experiments on the device performance, and study signal processing in the system. We also present experimental results for the proposed device and estimate the potentially achievable reading distance. UWB SAW tags will have an extremely small chip size (<0.5 x 1 mm(2)) and a low cost. They also can provide a large number of different codes. The estimated read range for UWB SAW tags is about 2 m with a reader radiating as low as <0.1 mW power levels with an extremely low duty factor.
Reed, Deborah K.; Swanson, Elizabeth; Petscher, Yaacov; Vaughn, Sharon
2015-01-01
Teacher read-alouds (TRA) are common in middle and high school content area classes. Because the practice of reading the textbook out loud to students is often used out of concern about students’ ability to understand and learn from text when reading silently (SR), this randomized controlled trial was designed to experimentally manipulate text reading while blocking on all other instructional elements to determine the relative effects on learning content. Predominantly Spanish–English bilingual twelfth-graders (n = 123) were randomly assigned to either a TRA or SR condition and provided 1 week of high quality instruction in US history. Daily lessons included teaching key terms in the passage, previewing text headings, and conducting comprehension checks. Results of immediate, 1-week delayed, and 1-month delayed assessments of content learning revealed no significant differences between the two groups. Students were also asked to rate the method of reading they believed best helped them understand and remember information. Students in the SR condition more consistently agreed that reading silently was beneficial. Findings suggest low performing adolescents of different linguistic backgrounds can learn content as well when reading appropriately challenging text silently as when the teacher reads the text aloud to them. PMID:26346215
1992-01-22
Onboard Space Shuttle Discovery (STS-42) Astronaut Norman E. Thagard, payload commander, and Canadian payload specialist Roberta L. Bondar are busily engaged with experiments in the International Microgravity Laboratory (IML-1) science module. Bondar reads a checklist near the Biorack while Thagard performs a VCR tape change-out. The two, along with four other NASA astronauts and a second IML-1 payload specialist spent more than eight days conducting experiments in Earth orbit. Part of the Space Acceleration Measurement System is in center foreground.
CCAM: A novel millimeter-wave instrument using a close-packed TES bolometer array
NASA Astrophysics Data System (ADS)
Lau, Judy M.
This thesis describes CCAM, an instrument designed to map the Cosmic Microwave Background (CMB), and also presents some of the initial measurements made with CCAM on the Atacama Cosmology Telescope (ACT). CCAM uses a CCD-like camera of millimeter-wave TES bolometers. It employs new detector technology, read-out electronics, cold re-imaging optics, and cryogenics to obtain high sensitivity CMB anisotropy measurements. The free-standing 8×32 close-packed array of pop- up TES detectors is the first of its kind to observe the sky at 145 GHz. We present the design of the receiver including the antireflection coated silicon lens re-imaging system, construction and optimization of the pulse tube/ sorption refrigerator cryogenic system, as well as the technology developed to integrate eight 1×32 TES columns and accompanying read-out electronics in to an array of 256 millimeter-wave detectors into a focal plane area of 3.5 cm 2. The performance of the detectors and optics prior to deployment at the ACT site in Chile are reported as well as preliminary performance results of the instrument when optically paired with the ACT telescope in the summer of 2007. Here, we also report on the feasibility of the TES detector array to measure polarization when coupled to a rotating birefringent sapphire half wave plate and wire-grid polarizer.
Validity of Single-Item Screening for Limited Health Literacy in English and Spanish Speakers.
Bishop, Wendy Pechero; Craddock Lee, Simon J; Skinner, Celette Sugg; Jones, Tiffany M; McCallister, Katharine; Tiro, Jasmin A
2016-05-01
To evaluate 3 single-item screening measures for limited health literacy in a community-based population of English and Spanish speakers. We recruited 324 English and 314 Spanish speakers from a community research registry in Dallas, Texas, enrolled between 2009 and 2012. We used 3 screening measures: (1) How would you rate your ability to read?; (2) How confident are you filling out medical forms by yourself?; and (3) How often do you have someone help you read hospital materials? In analyses stratified by language, we used area under the receiver operating characteristic (AUROC) curves to compare each item with the validated 40-item Short Test of Functional Health Literacy in Adults. For English speakers, no difference was seen among the items. For Spanish speakers, "ability to read" identified inadequate literacy better than "help reading hospital materials" (AUROC curve = 0.76 vs 0.65; P = .019). The "ability to read" item performed the best, supporting use as a screening tool in safety-net systems caring for diverse populations. Future studies should investigate how to implement brief measures in safety-net settings and whether highlighting health literacy level influences providers' communication practices and patient outcomes.
J. Hillis Miller's Virtual Reality of Reading
ERIC Educational Resources Information Center
Fosso, Kurt; Harp, Jerry
2012-01-01
We set out to investigate Miller's curious assertion--curious for a deconstructionist committed to a critique of the old metaphysics of presence--that literary works preexist their being written down. We find a basis for this sense of the preexistence of the literary work in Miller's insights about the performative dynamics of reading and writing.…
Reading Performance of Young Adults With ADHD Diagnosed in Childhood.
Miranda, Ana; Mercader, Jessica; Fernández, M Inmaculada; Colomer, Carla
2017-02-01
To study reading performance of young adults with ADHD and its relation with executive functioning. Thirty young adults with a childhood diagnosis of ADHD and 30 with normal development (ND) were compared on reading accuracy, fluency, and comprehension. Furthermore, ADHD with reading disabilities (ADHD+RD) and ADHD without reading disabilities (ADHD-RD) subgroups were compared using self-report and informant-report versions of the Behavior Rating Inventory of Executive Function-Adult version (BRIEF-A). Adults with ADHD obtained significantly worse results than the ND adults on reading speed, responses to literal questions, and a cloze test. Although the comparison of the ADHD+RD and ADHD-RD groups did not show significant differences on the BRIEF-A subscales, the ADHD+RD group surpassed the critical percentile (85) on more subscales, with working memory and metacognition especially affected. The findings point out that reading should be assessed in individuals with ADHD as part of their evaluation to design effective early interventions.
Optimization of a PCRAM Chip for high-speed read and highly reliable reset operations
NASA Astrophysics Data System (ADS)
Li, Xiaoyun; Chen, Houpeng; Li, Xi; Wang, Qian; Fan, Xi; Hu, Jiajun; Lei, Yu; Zhang, Qi; Tian, Zhen; Song, Zhitang
2016-10-01
The widely used traditional Flash memory suffers from its performance limits such as its serious crosstalk problems, and increasing complexity of floating gate scaling. Phase change random access memory (PCRAM) becomes one of the most potential nonvolatile memories among the new memory techniques. In this paper, a 1M-bit PCRAM chip is designed based on the SMIC 40nm CMOS technology. Focusing on the read and write performance, two new circuits with high-speed read operation and highly reliable reset operation are proposed. The high-speed read circuit effectively reduces the reading time from 74ns to 40ns. The double-mode reset circuit improves the chip yield. This 1M-bit PCRAM chip has been simulated on cadence. After layout design is completed, the chip will be taped out for post-test.
Screen Color and Reading Performance on Closed-Circuit Television.
ERIC Educational Resources Information Center
Jacobs, R. J.
1990-01-01
To investigate whether screen color is an important variable in the prescription of closed circuit television (CCTV) systems, 16 adults with low vision were assessed on reading performance on white, green, and amber screens. When the screen luminance and contrast were equated for each CCTV, subjects' reading performance was unaffected by screen…
Thaung, Jörgen; Olseke, Kjell; Ahl, Johan; Sjöstrand, Johan
2014-09-01
The purpose of our study was to establish a practical and quick test for assessing reading performance and to statistically analyse interchart and test-retest reliability of a new standardized Swedish reading chart system consisting of three charts constructed according to the principles available in the literature. Twenty-four subjects with healthy eyes, mean age 65 ± 10 years, were tested binocularly and the reading performance evaluated as reading acuity, critical print size and maximum reading speed. The test charts all consist of 12 short text sentences with a print size ranging from 0.9 to -0.2 logMAR in approximate steps of 0.1 logMAR. Two testing sessions, in two different groups (C1 and C2), were under strict control of luminance and lighting environment. Reading performance tests with chart T1, T2 and T3 were used for evaluation of interchart reliability and test data from a second session 1 month or more apart for the test-retest analysis. The testing of reading performance in adult observers with short sentences of continuous text was quick and practical. The agreement between the tests obtained with the three different test charts was high both within the same test session and at retest. This new Swedish variant of a standardized reading system based on short sentences and logarithmic progression of print size provides reliable measurements of reading performance and preliminary norms in an age group around 65 years. The reading test with three independent reading charts can be useful for clinical studies of reading ability before and after treatment. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Optical performance of prototype horn-coupled TES bolometer arrays for SAFARI
NASA Astrophysics Data System (ADS)
Audley, Michael D.; de Lange, Gert; Gao, Jian-Rong; Khosropanah, Pourya; Hijmering, Richard; Ridder, Marcel L.
2016-07-01
The SAFARI Detector Test Facility is an ultra-low background optical testbed for characterizing ultra-sensitive prototype horn-coupled TES bolmeters for SAFARI, the grating spectrometer on board the proposed SPICA satellite. The testbed contains internal cold and hot black-body illuminators and a light-pipe for illumination with an external source. We have added reimaging optics to facilitate array optical measurements. The system is now being used for optical testing of prototype detector arrays read out with frequency-domain multiplexing. We present our latest optical measurements of prototype arrays and discuss these in terms of the instrument performance.
NASA Astrophysics Data System (ADS)
Po'ad, F. A.; Ismail, W.; Jusoh, J. F.
2017-08-01
This paper describes the experiments and analysis conducted on 2.4 GHz embedded active Radio Frequency Identification (RFID) - Wireless Sensor Network (WSN) based system that has been developed for the purposes of location tracking and monitoring in indoor and outdoor environments. Several experiments are conducted to test the effectiveness and performance of the developed system and two of them is by measuring the Radio Frequency (RF) transmitting power and Received Signal Strength (RSS) to prove that the embedded active RFID tag is capable to generate higher transmit power during data transmission and able to provide better RSS reading compared to standalone RFID tag. Experiments are carried out on two RFID tags which are active RFID tag embedded with GPS and GSM (ER2G); and standalone RFID tag communicating with the same active RFID reader. The developed ER2G contributes 12.26 % transmit power and 6.47 % RSS reading higher than standalone RFID tag. The results conclude that the ER2G gives better performance compared to standalone RFID tag and can be used as guidelines for future design improvements.
The performance of the DELPHI hadron calorimeter at LEP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ajinenko, I.; Beloous, K.; Chudoba, J.
1996-06-01
The DELPHI Hadron Calorimeter was conceived more than ten years ago, as an instrument to measure the energy of hadrons and hadronic jets from e{sup +}e{sup {minus}} collisions at the CERN collider LEP. In addition it was expected to provide a certain degree of discrimination between pions and muons. The detector is a rather simple and relatively inexpensive device consisting of around 20,000 limited streamer plastic tubes, with inductive pad read-out, embedded in the iron yoke of the 1.2 T DELPHI magnet. Its depth is at minimum 6.6 nuclear interaction lengths. The electronics necessary for the pad readout was designedmore » to have an adequate performance for a reasonable cost. This detector has proved over six years of operation to have an entirely satisfactory performance and great reliability; for example less than 1% of the streamer tubes have failed and electronic problems remain at the per mil level. During the past two years an improvement program has been under way. It has been found possible to use the streamer tubes as strips, hence giving better granularity and particle tracking, by reading out the cathode of individual tubes. The constraints on this were considerable because of the inaccessibility of the detectors in the magnet yoke. However, a cheap and feasible solution has been found. The cathode readout leads to an improved energy resolution, better {mu} identification, a better {pi}/{mu} separation and to possibilities of neutral particle separation. The simultaneous anode read-out of several planes of the endcaps of the detector will provide a fast trigger in the forward/backward direction which is an important improvement for LEP200. On the barrel the system will provide a cosmic trigger which is very useful for calibration as counting rates at LEP200 will be very low.« less
ERIC Educational Resources Information Center
Chen, Chih-Ming; Wang, Jung-Ying; Chen, Yong-Ting; Wu, Jhih-Hao
2016-01-01
To reduce effectively the reading anxiety of learners while reading English articles, a C4.5 decision tree, a widely used data mining technique, was used to develop a personalized reading anxiety prediction model (PRAPM) based on individual learners' reading annotation behavior in a collaborative digital reading annotation system (CDRAS). In…
How to Communicate with a Machine: On Reading a Public Library's OPAC
ERIC Educational Resources Information Center
Saarti, Jarmo; Raivio, Jouko
2011-01-01
This article presents a reading of the user interface in one public library system. Its aim is to find out the frames and competences required and used in the communication between the computer and the patron. The authors see the computer as a text that is to be read by the user who wants to search for information from the library. The transition…
NASA Astrophysics Data System (ADS)
Kuenzig, Thomas; Dehé, Alfons; Krumbein, Ulrich; Schrag, Gabriele
2018-05-01
Maxing out the technological limits in order to satisfy the customers’ demands and obtain the best performance of micro-devices and-systems is a challenge of today’s manufacturers. Dedicated system simulation is key to investigate the potential of device and system concepts in order to identify the best design w.r.t. the given requirements. We present a tailored, physics-based system-level modeling approach combining lumped with distributed models that provides detailed insight into the device and system operation at low computational expense. The resulting transparent, scalable (i.e. reusable) and modularly composed models explicitly contain the physical dependency on all relevant parameters, thus being well suited for dedicated investigation and optimization of MEMS devices and systems. This is demonstrated for an industrial capacitive silicon microphone. The performance of such microphones is determined by distributed effects like viscous damping and inhomogeneous capacitance variation across the membrane as well as by system-level phenomena like package-induced acoustic effects and the impact of the electronic circuitry for biasing and read-out. The here presented model covers all relevant figures of merit and, thus, enables to evaluate the optimization potential of silicon microphones towards high fidelity applications. This work was carried out at the Technical University of Munich, Chair for Physics of Electrotechnology. Thomas Kuenzig is now with Infineon Technologies AG, Neubiberg.
Figuring out the Figurative: Understanding and Teaching Symbolism in Literary Texts
ERIC Educational Resources Information Center
Spratley Burtin, Anika
2009-01-01
Secondary student performance in the domain of reading has been a cause for concern for educators and scholars alike. To understand the demands placed on students we must first understand how reading changes within content areas and across grades. Furthermore, we must have an understanding of teachers' conceptions about the texts they teach. This…
High throughput reconfigurable data analysis system
NASA Technical Reports Server (NTRS)
Bearman, Greg (Inventor); Pelletier, Michael J. (Inventor); Seshadri, Suresh (Inventor); Pain, Bedabrata (Inventor)
2008-01-01
The present invention relates to a system and method for performing rapid and programmable analysis of data. The present invention relates to a reconfigurable detector comprising at least one array of a plurality of pixels, where each of the plurality of pixels can be selected to receive and read-out an input. The pixel array is divided into at least one pixel group for conducting a common predefined analysis. Each of the pixels has a programmable circuitry programmed with a dynamically configurable user-defined function to modify the input. The present detector also comprises a summing circuit designed to sum the modified input.
NASA Astrophysics Data System (ADS)
Donchenko, Sergey S.; Odinokov, Sergey B.; Betin, Alexandr U.; Hanevich, Pavel; Semishko, Sergey; Zlokazov, Evgenii Y.
2017-05-01
The holographic disk reading device for recovery of CGFH is described. Principle of its work is shown. Analyzed approaches for developing algorithms, used in this device: guidance and decoding. Listed results of experimental researches.
ARNICA and LonGSp: the refurbishment of two near infrared instruments
NASA Astrophysics Data System (ADS)
Koshida, Shintaro; Vanzi, Leonardo; Guzman, Dani; Leiva, Rodrigo; Bonati, Marco A.; Avilés, Roberto L.; Baffa, Carlo; Palla, Francesco; Mannucci, Filippo; Shen, Tzu Chiang; Suc, Vincent
2014-07-01
ARNICA and LonGSp are two NICMOS based near infrared instruments developed in the 90's by the Astrophysical Observatory of Arcetri. After more than 10 years from decommissioning we refurbished the two instruments with a new read-out electronics and control software. We present the performances of the refurbished systems and compare them with the historic behavior. Both instruments are currently used for testing purposes in the Lab and at the telescope, we present some example applications.
Performance of the Fully Digital FPGA-Based Front-End Electronics for the GALILEO Array
NASA Astrophysics Data System (ADS)
Barrientos, D.; Bellato, M.; Bazzacco, D.; Bortolato, D.; Cocconi, P.; Gadea, A.; González, V.; Gulmini, M.; Isocrate, R.; Mengoni, D.; Pullia, A.; Recchia, F.; Rosso, D.; Sanchis, E.; Toniolo, N.; Ur, C. A.; Valiente-Dobón, J. J.
2015-12-01
In this work we present the architecture and results of a fully digital Front End Electronics (FEE) read out system developed for the GALILEO array. The FEE system, developed in collaboration with the Advanced Gamma Tracking Array (AGATA) collaboration, is composed of three main blocks: preamplifiers, digitizers and preprocessing electronics. The slow control system contains a custom Linux driver, a dynamic library and a server implementing network services. This work presents the first results of the digital FEE system coupled with a GALILEO germanium detector, which has demonstrated the capability to achieve an energy resolution of 1.530/00 at an energy of 1.33 MeV, similar to the one obtained with a conventional analog system. While keeping a good performance in terms of energy resolution, digital electronics will allow to instrument the full GALILEO array with a versatile system with high integration and low power consumption and costs.
Design, fabrication and characterisation of a microfluidic time-temperature indicator
NASA Astrophysics Data System (ADS)
Schmitt, P.; Wedrich, K.; Müller, L.; Mehner, H.; Hoffmann, M.
2017-11-01
This paper describes a concept for a passive microfluidic time-temperature indicator (TTI) intended for intelligent food packaging. A microfluidic system is presented that makes use of the temperature-dependent flow of suitable food ingredients in a microcapillary. Based on the creeping distance inside the capillary, the time-temperature integral can be determined. A demonstrator of the microsystem has been designed, fabricated and characterised using liquid sugar alcohols as indicator fluids. To enable a first wireless read-out of the passive TTI, the sensor was read out using a commercial RFID equipment, and capacitive measurements have been carried out.
The Muon Portal Double Tracker for the Inspection of Travelling Containers
NASA Astrophysics Data System (ADS)
Pugliatti, C.; Antonuccio, V.; Bandieramonte, M.; Becciani, U.; Belluomo, F.; Blancato, A.; Bonanno, G.; Costa, A.; Fallica, P. G.; Garozzo, S.; Grillo, A.; Indelicato, V.; La Rocca, P.; Leonora, E.; Longhitano, F.; Longo, S.; Lo Presti, D.; Marano, D.; Massimino, P.; Petta, C.; Pistagna, C.; Puglisi, M.; Randazzo, N.; Riggi, F.; Riggi, S.; Romeo, G.; Russo, G. V.; Santagati, G.; Timpanaro, M. C.; Valvo, G.; Vitello, F.; Zaia, A.
2015-12-01
The Muon Portal Project has as its goal the design and construction of a real-size working detector prototype in scale 1:1, to inspect the content of travelling containers by means of the secondary cosmic-ray muon radiation and to recognize high-Z hidden materials (i.e. U, Pu). The tomographic image is obtained by reconstructing the input and output trajectories of each muon when it crosses the container and, consequently, the scattering angle, making use of two trackers placed above and below the container. The scan is performed without adding any external radiation, in a reasonable time (few minutes) and with a good spatial and angular resolution. The detector consists of 8 planes each segmented in 6 identical modules. Each module is made of scintillating strips with two WaveLength Shifting fibers (WLS) inside, coupled to Silicon photomultipliers. The customized read-out electronics employs programmable boards. Thanks to a smart read-out system, the number of output channels is reduced by a factor 10. The signals from the front-end modules are sent to the read-out boards, in order to convert analog signals to digital ones, by comparison with a threshold. The data are pre-analyzed and stored into a data acquisition PC. After an intense measurement and simulation campaign to carefully characterize the detector components, the first detection modules ( 1 ×3 m2) have been already built. In this paper the detector architecture, particularly focusing on the used electronics and the main preliminary results will be presented.
Repeated readings and science: Fluency with expository passages
NASA Astrophysics Data System (ADS)
Kostewicz, Douglas E.
The current study investigated the effects of repeated readings to a fluency criterion (RRFC) for seven students with disabilities using science text. The study employed a single subject design, specifically, two multiple probe multiple baselines across subjects, to evaluate the effects of the RRFC intervention. Results indicated that students met criterion (200 or more correct words per minute with 2 or fewer errors) on four consecutive passages. A majority of students displayed accelerations to correct words per minute and decelerations to incorrect words per minute on successive initial, intervention readings suggesting reading transfer. Students' reading scores during posttest and maintenance out performed pre-test and baseline readings provided additional measures of reading transfer. For a relationship to comprehension, students scored higher on oral retell measures after meeting criterion as compared to initial readings. Overall, the research findings suggested that the RRFC intervention improves science reading fluency for students with disabilities, and may also indirectly benefit comprehension.
Sub-micron accurate track navigation method ``Navi'' for the analysis of Nuclear Emulsion
NASA Astrophysics Data System (ADS)
Yoshioka, T.; Yoshida, J.; Kodama, K.
2011-03-01
Sub-micron accurate track navigation in Nuclear Emulsion is realized by using low energy signals detected by automated Nuclear Emulsion read-out systems. Using those much dense ``noise'', about 104 times larger than the real tracks, the accuracy of the track position navigation reaches to be sub micron only by using the information of a microscope field of view, 200 micron times 200 micron. This method is applied to OPERA analysis in Japan, i.e. support of human eye checks of the candidate tracks, confirmation of neutrino interaction vertexes and to embed missing track segments to the track data read-out by automated systems.
CMOS Active Pixel Sensors as energy-range detectors for proton Computed Tomography.
Esposito, M; Anaxagoras, T; Evans, P M; Green, S; Manolopoulos, S; Nieto-Camero, J; Parker, D J; Poludniowski, G; Price, T; Waltham, C; Allinson, N M
2015-06-03
Since the first proof of concept in the early 70s, a number of technologies has been proposed to perform proton CT (pCT), as a means of mapping tissue stopping power for accurate treatment planning in proton therapy. Previous prototypes of energy-range detectors for pCT have been mainly based on the use of scintillator-based calorimeters, to measure proton residual energy after passing through the patient. However, such an approach is limited by the need for only a single proton passing through the energy-range detector in a read-out cycle. A novel approach to this problem could be the use of pixelated detectors, where the independent read-out of each pixel allows to measure simultaneously the residual energy of a number of protons in the same read-out cycle, facilitating a faster and more efficient pCT scan. This paper investigates the suitability of CMOS Active Pixel Sensors (APSs) to track individual protons as they go through a number of CMOS layers, forming an energy-range telescope. Measurements performed at the iThemba Laboratories will be presented and analysed in terms of correlation, to confirm capability of proton tracking for CMOS APSs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
St James, S; Argento, D; DeWitt, D
Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilationmore » photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.« less
The design, status and performance of the ZEUS central tracking detector electronics
NASA Astrophysics Data System (ADS)
Cussans, D. G.; Fawcett, H. F.; Foster, B.; Gilmore, R. S.; Heath, G. P.; Llewellyn, T. J.; Malos, J.; Morgado, C. J. S.; Tapper, R. J.; Gingrich, D. M.; Harnew, N.; Hallam-Baker, P.; Nash, J.; Khatri, T.; Shield, P. D.; McArthur, I.; Topp-Jorgensen, S.; Wilson, F. F.; Allen, D.; Baird, S. A.; Carter, R.; Galagardera, S.; Gibson, M. D.; Hatley, R. S.; Jeffs, M.; Milborrow, R.; Morissey, M.; Quinton, S. P. H.; White, D. J.; Lane, J.; Nixon, G.; Postranecky, M.; Jamdagni, A. K.; Marcou, C.; Miller, D. B.; Toudup, L.
1992-05-01
The readout system developed for the ZEUS central trackign detector (CDT) is described. The CTD is required to provide an accurate measurement of the sagitta and energy loss of charged particles as well as provide fast trigger information. This must be carried out in the HERA environment in which beams cross every 96 ns. The first two aims are achieved by digitizing chamber pulses using a pipelined 104 MHz FADC system. The trigger uses a fast determination of the difference in the arrival times of a pulse at each end of the CTD. It processes this data and gives information to the ZEUS global first level trigger. The modules are housed in custom-built racks and crates and read out using a DAQ system based on Transputer readout controllers. These also monitor data quality and produce data for the ZEUS second level Trigger.
Prick test: evolution towards automated reading.
Justo, X; Díaz, I; Gil, J J; Gastaminza, G
2016-08-01
The prick test is one of the most common medical methods for diagnosing allergies, and it has been carried out in a similar and laborious manner over many decades. In an attempt to standardize the reading of the test, many researchers have tried to automate the process of measuring the allergic reactions found by developing systems and algorithms based on multiple technologies. This work reviews the techniques for automatic wheal measurement with the aim of pointing out their advantages and disadvantages and the progress in the field. Furthermore, it provides a classification scheme for the different technologies applied. The works discussed herein provide evidence that significant challenges still exist for the development of an automatic wheal measurement system that not only helps allergists in their medical practice but also allows for the standardization of the reading and data exchange. As such, the aim of the work was to serve as guideline for the development of a proper and feasible system. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Performance studies of X3 silicon detectors for the future ELISSA array at ELI-NP
NASA Astrophysics Data System (ADS)
Chesnevskaya, S.; Balabanski, D. L.; Choudhury, D.; Constantin, P.; Filipescu, D. M.; Ghita, D. G.; Guardo, G. L.; Lattuada, D.; Matei, C.; Rotaru, A.; State, A.
2018-05-01
ELISSA is an array of silicon strip detectors under construction at the ELI-NP facility for measurements of photodissociation reactions using high-brilliance, quasi monoenergetic gamma beams. The detection system consists of 35 single-sided position-sensitive X3 detectors arranged in a cylindrical configuration and eight QQQ3 detectors as end-caps. A batch of forty X3 detectors have been tested at ELI-NP. The energy and position resolution, ballistic deficit, leakage currents, and depletion voltage were measured and analyzed. Measurements of the energy resolution were carried out using two read-out electronic chains, one based on multichannel preamplifiers and another based on multiplexers.
Application of the high resolution return beam vidicon
NASA Technical Reports Server (NTRS)
Cantella, M. J.
1977-01-01
The Return Beam Vidicon (RBV) is a high-performance electronic image sensor and electrical storage component. It can accept continuous or discrete exposures. Information can be read out with a single scan or with many repetitive scans for either signal processing or display. Resolution capability is 10,000 TV lines/height, and at 100 lp/mm, performance matches or exceeds that of film, particularly with low-contrast imagery. Electronic zoom can be employed effectively for image magnification and data compression. The high performance and flexibility of the RBV permit wide application in systems for reconnaissance, scan conversion, information storage and retrieval, and automatic inspection and test. This paper summarizes the characteristics and performance parameters of the RBV and cites examples of feasible applications.
How the Brain's Performance during Mathematics and Reading Fluency Tests Compare
ERIC Educational Resources Information Center
Ortiz, Enrique
2011-01-01
The purpose of this study was to analyze how participants' levels of hemoglobin as they performed mathematics fluency and reading fluency (reading comprehension) compare. We used Optical Topography (OT, helmet type brain-scanning system, also known as Functional Near-Infrared Spectroscopy or fNIRS) to measure levels of brain activity. A central…
CMOS imager for pointing and tracking applications
NASA Technical Reports Server (NTRS)
Sun, Chao (Inventor); Pain, Bedabrata (Inventor); Yang, Guang (Inventor); Heynssens, Julie B. (Inventor)
2006-01-01
Systems and techniques to realize pointing and tracking applications with CMOS imaging devices. In general, in one implementation, the technique includes: sampling multiple rows and multiple columns of an active pixel sensor array into a memory array (e.g., an on-chip memory array), and reading out the multiple rows and multiple columns sampled in the memory array to provide image data with reduced motion artifact. Various operation modes may be provided, including TDS, CDS, CQS, a tracking mode to read out multiple windows, and/or a mode employing a sample-first-read-later readout scheme. The tracking mode can take advantage of a diagonal switch array. The diagonal switch array, the active pixel sensor array and the memory array can be integrated onto a single imager chip with a controller. This imager device can be part of a larger imaging system for both space-based applications and terrestrial applications.
Readout of a 176 pixel FDM system for SAFARI TES arrays
NASA Astrophysics Data System (ADS)
Hijmering, R. A.; den Hartog, R.; Ridder, M.; van der Linden, A. J.; van der Kuur, J.; Gao, J. R.; Jackson, B.
2016-07-01
In this paper we present the results of our 176-pixel prototype of the FDM readout system for SAFARI, a TES-based focal-plane instrument for the far-IR SPICA mission. We have implemented the knowledge obtained from the detailed study on electrical crosstalk reported previously. The effect of carrier leakage is reduced by a factor two, mutual impedance is reduced to below 1 nH and mutual inductance is removed. The pixels are connected in stages, one quarter of the array half of the array and the full array, to resolve intermediate technical issues. A semi-automated procedure was incorporated to find all optimal settings for all pixels. And as a final step the complete array has been connected and 132 pixels have been read out simultaneously within the frequency range of 1-3.8MHz with an average frequency separation of 16kHz. The noise was found to be detector limited and was not affected by reading out all pixels in a FDM mode. With this result the concept of using FDM for multiplexed bolometer read out for the SAFARI instrument has been demonstrated.
Detector Developments for the High Luminosity LHC Era (2/4)
Straessner, Arno
2018-04-16
Calorimetry and Muon Spectromers - Part II: When upgrading the LHC to higher luminosities, the detector and trigger performance shall be preserved - if not improved - with respect to the nominal performance. The ongoing R&D; for new radiation tolerant front-end electronics for calorimeters with higher read-out bandwidth are summarized and new possibilities for the trigger systems are presented. Similar developments are foreseen for the muon spectrometers, where also radiation tolerance of the muon detectors and functioning at high background rates is important. The corresponding plans and research work for the calorimeter and muon detectors at a LHC with highest luminsity are presented.
A Secure Alignment Algorithm for Mapping Short Reads to Human Genome.
Zhao, Yongan; Wang, Xiaofeng; Tang, Haixu
2018-05-09
The elastic and inexpensive computing resources such as clouds have been recognized as a useful solution to analyzing massive human genomic data (e.g., acquired by using next-generation sequencers) in biomedical researches. However, outsourcing human genome computation to public or commercial clouds was hindered due to privacy concerns: even a small number of human genome sequences contain sufficient information for identifying the donor of the genomic data. This issue cannot be directly addressed by existing security and cryptographic techniques (such as homomorphic encryption), because they are too heavyweight to carry out practical genome computation tasks on massive data. In this article, we present a secure algorithm to accomplish the read mapping, one of the most basic tasks in human genomic data analysis based on a hybrid cloud computing model. Comparing with the existing approaches, our algorithm delegates most computation to the public cloud, while only performing encryption and decryption on the private cloud, and thus makes the maximum use of the computing resource of the public cloud. Furthermore, our algorithm reports similar results as the nonsecure read mapping algorithms, including the alignment between reads and the reference genome, which can be directly used in the downstream analysis such as the inference of genomic variations. We implemented the algorithm in C++ and Python on a hybrid cloud system, in which the public cloud uses an Apache Spark system.
Real-time operation without a real-time operating system for instrument control and data acquisition
NASA Astrophysics Data System (ADS)
Klein, Randolf; Poglitsch, Albrecht; Fumi, Fabio; Geis, Norbert; Hamidouche, Murad; Hoenle, Rainer; Looney, Leslie; Raab, Walfried; Viehhauser, Werner
2004-09-01
We are building the Field-Imaging Far-Infrared Line Spectrometer (FIFI LS) for the US-German airborne observatory SOFIA. The detector read-out system is driven by a clock signal at a certain frequency. This signal has to be provided and all other sub-systems have to work synchronously to this clock. The data generated by the instrument has to be received by a computer in a timely manner. Usually these requirements are met with a real-time operating system (RTOS). In this presentation we want to show how we meet these demands differently avoiding the stiffness of an RTOS. Digital I/O-cards with a large buffer separate the asynchronous working computers and the synchronous working instrument. The advantage is that the data processing computers do not need to process the data in real-time. It is sufficient that the computer can process the incoming data stream on average. But since the data is read-in synchronously, problems of relating commands and responses (data) have to be solved: The data is arriving at a fixed rate. The receiving I/O-card buffers the data in its buffer until the computer can access it. To relate the data to commands sent previously, the data is tagged by counters in the read-out electronics. These counters count the system's heartbeat and signals derived from that. The heartbeat and control signals synchronous with the heartbeat are sent by an I/O-card working as pattern generator. Its buffer gets continously programmed with a pattern which is clocked out on the control lines. A counter in the I/O-card keeps track of the amount of pattern words clocked out. By reading this counter, the computer knows the state of the instrument or knows the meaning of the data that will arrive with a certain time-tag.
PSSA Released Reading Items, 2000-2001. The Pennsylvania System of School Assessment.
ERIC Educational Resources Information Center
Pennsylvania State Dept. of Education, Harrisburg. Bureau of Curriculum and Academic Services.
This document contains materials directly related to the actual reading test of the Pennsylvania System of School Assessment (PSSA), including the reading rubric, released passages, selected-response questions with answer keys, performance tasks, and scored samples of students' responses to the tasks. All of these items may be duplicated to…
NASA Astrophysics Data System (ADS)
Larger, Laurent; Baylón-Fuentes, Antonio; Martinenghi, Romain; Udaltsov, Vladimir S.; Chembo, Yanne K.; Jacquot, Maxime
2017-01-01
Reservoir computing, originally referred to as an echo state network or a liquid state machine, is a brain-inspired paradigm for processing temporal information. It involves learning a "read-out" interpretation for nonlinear transients developed by high-dimensional dynamics when the latter is excited by the information signal to be processed. This novel computational paradigm is derived from recurrent neural network and machine learning techniques. It has recently been implemented in photonic hardware for a dynamical system, which opens the path to ultrafast brain-inspired computing. We report on a novel implementation involving an electro-optic phase-delay dynamics designed with off-the-shelf optoelectronic telecom devices, thus providing the targeted wide bandwidth. Computational efficiency is demonstrated experimentally with speech-recognition tasks. State-of-the-art speed performances reach one million words per second, with very low word error rate. Additionally, to record speed processing, our investigations have revealed computing-efficiency improvements through yet-unexplored temporal-information-processing techniques, such as simultaneous multisample injection and pitched sampling at the read-out compared to information "write-in".
Design of a muonic tomographic detector to scan travelling containers
NASA Astrophysics Data System (ADS)
Pugliatti, C.; Antonuccio, V.; Bandieramonte, M.; Becciani, U.; Belluomo, F.; Belluso, M.; Billotta, S.; Blancato, A. A.; Bonanno, D. L.; Bonanno, G.; Costa, A.; Fallica, G.; Garozzo, S.; Indelicato, V.; La Rocca, P.; Leonora, E.; Longhitano, F.; Longo, S.; Lo Presti, D.; Massimino, P.; Petta, C.; Pistagna, C.; Puglisi, M.; Randazzo, N.; Riggi, F.; Riggi, S.; Romeo, G.; Russo, G. V.; Santagati, G.; Valvo, G.; Vitello, F.; Zaia, A.; Zappalà, G.
2014-05-01
The Muon Portal Project aims at the construction of a large volume detector to inspect the content of travelling containers for the identification of high-Z hidden materials (U, Pu or other fissile samples), exploiting the secondary cosmic-ray muon radiation. An image of these materials is achieved reconstructing the deviations of the muons from their original trajectories inside the detector volume, by means of two particle trackers, placed one below and one above the container. The scan is performed without adding any external radiation, in a few minutes and with a high spatial and angular resolution. The detector consists of 4800 scintillating strips with two wavelength shifting (WLS) fibers inside each strip, coupled to Silicon photomultipliers (SiPMs). A smart strategy for the read out system allows a considerable reduction of the number of the read-out channels. Actually, an intense measurement campaign is in progress to carefully characterize any single component of the detector. A prototype of one of the 48 detection modules (1 × 3 m2) is actually under construction. This paper presents the detector architecture and the preliminary results.
A neutron dosemeter for nuclear criticality accidents.
d'Errico, F; Curzio, G; Ciolini, R; Del Gratta, A; Nath, R
2004-01-01
A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.
Developments on a SEM-based X-ray tomography system: Stabilization scheme and performance evaluation
NASA Astrophysics Data System (ADS)
Gomes Perini, L. A.; Bleuet, P.; Filevich, J.; Parker, W.; Buijsse, B.; Kwakman, L. F. Tz.
2017-06-01
Recent improvements in a SEM-based X-ray tomography system are described. In this type of equipment, X-rays are generated through the interaction between a highly focused electron-beam and a geometrically confined anode target. Unwanted long-term drifts of the e-beam can lead to loss of X-ray flux or decrease of spatial resolution in images. To circumvent this issue, a closed-loop control using FFT-based image correlation is integrated to the acquisition routine, in order to provide an in-line drift correction. The X-ray detection system consists of a state-of-the-art scientific CMOS camera (indirect detection), featuring high quantum efficiency (˜60%) and low read-out noise (˜1.2 electrons). The system performance is evaluated in terms of resolution, detectability, and scanning times for applications covering three different scientific fields: microelectronics, technical textile, and material science.
Posso, Margarita; Carles, Misericòrdia; Rué, Montserrat; Puig, Teresa; Bonfill, Xavier
2016-01-01
Objectives The usual practice in breast cancer screening programmes for mammogram interpretation is to perform double reading. However, little is known about its cost-effectiveness in the context of digital mammography. Our purpose was to evaluate the cost-effectiveness of double reading versus single reading of digital mammograms in a population-based breast cancer screening programme. Methods Data from 28,636 screened women was used to establish a decision-tree model and to compare three strategies: 1) double reading; 2) double reading for women in their first participation and single reading for women in their subsequent participations; and 3) single reading. We calculated the incremental cost-effectiveness ratio (ICER), which was defined as the expected cost per one additionally detected cancer. We performed a deterministic sensitivity analysis to test the robustness of the ICER. Results The detection rate of double reading (5.17‰) was similar to that of single reading (4.78‰; P = .768). The mean cost of each detected cancer was €8,912 for double reading and €8,287 for single reading. The ICER of double reading versus single reading was €16,684. The sensitivity analysis showed variations in the ICER according to the sensitivity of reading strategies. The strategy that combines double reading in first participation with single reading in subsequent participations was ruled out due to extended dominance. Conclusions From our results, double reading appears not to be a cost-effective strategy in the context of digital mammography. Double reading would eventually be challenged in screening programmes, as single reading might entail important net savings without significantly changing the cancer detection rate. These results are not conclusive and should be confirmed in prospective studies that investigate long-term outcomes like quality adjusted life years (QALYs). PMID:27459663
Network-based reading system for lung cancer screening CT
NASA Astrophysics Data System (ADS)
Fujino, Yuichi; Fujimura, Kaori; Nomura, Shin-ichiro; Kawashima, Harumi; Tsuchikawa, Megumu; Matsumoto, Toru; Nagao, Kei-ichi; Uruma, Takahiro; Yamamoto, Shinji; Takizawa, Hotaka; Kuroda, Chikazumi; Nakayama, Tomio
2006-03-01
This research aims to support chest computed tomography (CT) medical checkups to decrease the death rate by lung cancer. We have developed a remote cooperative reading system for lung cancer screening over the Internet, a secure transmission function, and a cooperative reading environment. It is called the Network-based Reading System. A telemedicine system involves many issues, such as network costs and data security if we use it over the Internet, which is an open network. In Japan, broadband access is widespread and its cost is the lowest in the world. We developed our system considering human machine interface and security. It consists of data entry terminals, a database server, a computer aided diagnosis (CAD) system, and some reading terminals. It uses a secure Digital Imaging and Communication in Medicine (DICOM) encrypting method and Public Key Infrastructure (PKI) based secure DICOM image data distribution. We carried out an experimental trial over the Japan Gigabit Network (JGN), which is the testbed for the Japanese next-generation network, and conducted verification experiments of secure screening image distribution, some kinds of data addition, and remote cooperative reading. We found that network bandwidth of about 1.5 Mbps enabled distribution of screening images and cooperative reading and that the encryption and image distribution methods we proposed were applicable to the encryption and distribution of general DICOM images via the Internet.
NTD-GE Based Microcalorimeter Performance
NASA Technical Reports Server (NTRS)
Bandler, Simon; Silver, Eric; Schnopper, Herbert; Murray, Stephen; Barbera, Marco; Madden, Norm; Landis, Don; Beeman, Jeff; Haller, Eugene; Tucker, Greg
2000-01-01
Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the primary broadening source. We mention our strategy for finding a suitable solution to this problem and describe briefly a technology for building arrays of these calorimeters.
Single-shot readout of accumulation mode Si/SiGe spin qubits using RF reflectometry
NASA Astrophysics Data System (ADS)
Volk, Christian; Martins, Frederico; Malinowski, Filip; Marcus, Charles M.; Kuemmeth, Ferdinand
Spin qubits based on gate-defined quantum dots are promising systems for realizing quantum computation. Due to their low concentration of nuclear-spin-carrying isotopes, Si/SiGe heterostructures are of particular interest. While high fidelities have been reported for single-qubit and two-qubit gate operations, qubit initialization and measurement times are relatively slow. In order to develop fast read-out techniques compatible with the operation of spin qubits, we characterize double and triple quantum dots confined in undoped Si/Si0.7Ge0.3 heterostructures using accumulation and depletion gates and a nearby RF charge sensor dot. We implement a RF reflectometry technique that allows single-shot charge read-out at integration times on the order of a few μs. We show our recent advancement towards implementing spin qubits in these structures, including spin-selective single-shot read-out.
Boyer, Catherine; Trudeau, Natacha; Sutton, Ann
2012-06-01
In order to understand a sequence of graphic symbols as sentences, one must not only recognize the meaning of individual symbols but also integrate their meaning together. In this study children without disabilities were asked to perform two tasks that presented sequences of graphics as stimuli but that differed in the need to treat the symbols as a sentence (i.e., with evidence of relationships among the individual symbols): a "reading" task (transpose the symbol sequence into speech), and an act-out task (demonstrate the meaning of the symbol sequences using puppets). The participants, aged 3 (n=18), 4 (n=36), 5 (n=27), and 6 (n=23) years, all succeeded on the reading task, but the younger groups were much less successful than the older groups on the act-out task. The children were more likely to pass the act-out task if they used conjugated rather than infinitive verb forms in their spoken responses on the reading task. In the younger age groups, children who used conjugated verb forms had higher receptive vocabulary scores. The findings suggest that being able to reproduce a sequence of symbols does not guarantee that the symbols are treated as a sentence. The inclusion in the study of children who were able to respond using speech, permitted observation of two types of responses (conjugated versus infinitive verb forms) that revealed different levels of understanding of graphic symbol sequences.
Reading Strategies in Spanish Developmental Dyslexics
ERIC Educational Resources Information Center
Suarez-Coalla, Paz; Cuetos, Fernando
2012-01-01
Cross-linguistic studies suggest that the orthographic system determines the reading performance of dyslexic children. In opaque orthographies, the fundamental feature of developmental dyslexia is difficulty in reading accuracy, whereas slower reading speed is more common in transparent orthographies. The aim of the current study was to examine…
Live event reconstruction in an optically read out GEM-based TPC
NASA Astrophysics Data System (ADS)
Brunbauer, F. M.; Galgóczi, G.; Gonzalez Diaz, D.; Oliveri, E.; Resnati, F.; Ropelewski, L.; Streli, C.; Thuiner, P.; van Stenis, M.
2018-04-01
Combining strong signal amplification made possible by Gaseous Electron Multipliers (GEMs) with the high spatial resolution provided by optical readout, highly performing radiation detectors can be realized. An optically read out GEM-based Time Projection Chamber (TPC) is presented. The device permits 3D track reconstruction by combining the 2D projections obtained with a CCD camera with timing information from a photomultiplier tube. Owing to the intuitive 2D representation of the tracks in the images and to automated control, data acquisition and event reconstruction algorithms, the optically read out TPC permits live display of reconstructed tracks in three dimensions. An Ar/CF4 (80/20%) gas mixture was used to maximize scintillation yield in the visible wavelength region matching the quantum efficiency of the camera. The device is integrated in a UHV-grade vessel allowing for precise control of the gas composition and purity. Long term studies in sealed mode operation revealed a minor decrease in the scintillation light intensity.
A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read out
NASA Astrophysics Data System (ADS)
Branchini, P.; Ceradini, F.; Corradi, G.; Di Micco, B.; Passeri, A.
2009-12-01
The construction and tests performed on a smal prototype of lead-scintillating fiber calorimeter instrumented with multianode photomultipliers are reported. The prototype is 15 cm wide, 15 radiation lenghts deep and is made of 200 layers of 50 cm long fibers. One side of the calorimeter has been instrumented with an array of 3 × 5 multianode R8900-M16 Hamamatsu photomultipliers, each segmented with a matrix of 4 × 4 anodes. The read-out granularity is 240 pixels 11 × 11 mm 2 reading about 64 fibers each. They are interfaced to the 6 × 6 mm 2 pixelled photocade with truncated pyramid light guides made of BC-800 plastic, UV transparent. Moreover each photomultiplier provides also the OR information of the last 12 dynodes. This information can be useful for trigger purposes. The response of the individual anodes, their relative gain and cross-talk has been measured with a 404 nm picosecond laser illuminating only a few fibers on the opposite side of the read-out. We also present first results of the calorimeter response to cosmic rays and electron beam data collected at BTF facility in Frascati.
NASA Astrophysics Data System (ADS)
Lucchini, Marco; CMS Collaboration
2017-11-01
The harsh radiation environment in which detectors will have to operate during the High Luminosity phase of LHC (HL-LHC) represents a crucial challenge for many calorimeter technologies. In the CMS forward calorimeters, ionizing doses and hadron fluences will reach up to 300 kGy (at a dose rate of 30 Gy/h) and 2 × 1014 cm-2, respectively, at the pseudo-rapidity region of |η| = 2.6. To evaluate the evolution of the CMS ECAL performance in such conditions, a set of PbWO4 crystals, exposed to 24 GeV protons up to integrated fluences between 2.1 × 1013 cm-2 and 1:3 × 1014 cm2, has been studied in beam tests. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The evolution of the PbWO4 crystals calorimetric performance has been well understood and parameterized in terms of increasing light absorption inside the crystal volume. A double-ended read-out configuration, in which two identical photodetectors are coupled to the opposite ends of each crystal, has also been tested. The separate and simultaneous read out of the light from the two ends of the crystal allows to correct for longitudinal shower fluctuations and to mitigate the degradation of energy resolution in highly damaged crystals. The non-linear response to electromagnetic showers, arising from high non-uniformity of light collection efficiency along the longitudinal axis of irradiated crystals, can also be corrected by means of the double-ended read-out technique.
Electron trapping optical data storage system and applications
NASA Technical Reports Server (NTRS)
Brower, Daniel; Earman, Allen; Chaffin, M. H.
1993-01-01
A new technology developed at Optex Corporation out-performs all other existing data storage technologies. The Electron Trapping Optical Memory (ETOM) media stores 14 gigabytes of uncompressed data on a single, double-sided 130 mm disk with a data transfer rate of up to 120 megabits per second. The disk is removable, compact, lightweight, environmentally stable, and robust. Since the Write/Read/Erase (W/R/E) processes are carried out photonically, no heating of the recording media is required. Therefore, the storage media suffers no deleterious effects from repeated W/R/E cycling. This rewritable data storage technology has been developed for use as a basis for numerous data storage products. Industries that can benefit from the ETOM data storage technologies include: satellite data and information systems, broadcasting, video distribution, image processing and enhancement, and telecommunications. Products developed for these industries are well suited for the demanding store-and-forward buffer systems, data storage, and digital video systems needed for these applications.
2011-01-01
Background Until recently, read lengths on the Solexa/Illumina system were too short to reliably assemble transcriptomes without a reference sequence, especially for non-model organisms. However, with read lengths up to 100 nucleotides available in the current version, an assembly without reference genome should be possible. For this study we created an EST data set for the common pond snail Radix balthica by Illumina sequencing of a normalized transcriptome. Performance of three different short read assemblers was compared with respect to: the number of contigs, their length, depth of coverage, their quality in various BLAST searches and the alignment to mitochondrial genes. Results A single sequencing run of a normalized RNA pool resulted in 16,923,850 paired end reads with median read length of 61 bases. The assemblies generated by VELVET, OASES, and SeqMan NGEN differed in the total number of contigs, contig length, the number and quality of gene hits obtained by BLAST searches against various databases, and contig performance in the mt genome comparison. While VELVET produced the highest overall number of contigs, a large fraction of these were of small size (< 200bp), and gave redundant hits in BLAST searches and the mt genome alignment. The best overall contig performance resulted from the NGEN assembly. It produced the second largest number of contigs, which on average were comparable to the OASES contigs but gave the highest number of gene hits in two out of four BLAST searches against different reference databases. A subsequent meta-assembly of the four contig sets resulted in larger contigs, less redundancy and a higher number of BLAST hits. Conclusion Our results document the first de novo transcriptome assembly of a non-model species using Illumina sequencing data. We show that de novo transcriptome assembly using this approach yields results useful for downstream applications, in particular if a meta-assembly of contig sets is used to increase contig quality. These results highlight the ongoing need for improvements in assembly methodology. PMID:21679424
Making Sense of Reading Scores with Reading Evaluation and Decoding System (READS)
ERIC Educational Resources Information Center
Mohamed, Abdul Rashid; Eng, Lin Siew; Ismail, Shaik Abdul Malik Mohamed
2010-01-01
It is imperative that teachers need to assess their learners' reading proficiency. Incidentally, most assessments developed and conducted by teachers merely discriminate who among their learners are performing better than the other. These assessments deplorably provide nothing more than norm reference data. Nonetheless, this is the only…
Using E-Readers and Internet Resources to Support Comprehension
ERIC Educational Resources Information Center
Wright, Sandra; Fugett, April; Caputa, Francine
2013-01-01
The advancements of technology have led to the use of electronic reading systems for digital text. Research indicates similarities and differences in reading performance and comprehension in digital formats compared to paper formats. This study compared vocabulary understanding and reading comprehension scores from two reading sources (electronic…
A Versatile Multichannel Digital Signal Processing Module for Microcalorimeter Arrays
NASA Astrophysics Data System (ADS)
Tan, H.; Collins, J. W.; Walby, M.; Hennig, W.; Warburton, W. K.; Grudberg, P.
2012-06-01
Different techniques have been developed for reading out microcalorimeter sensor arrays: individual outputs for small arrays, and time-division or frequency-division or code-division multiplexing for large arrays. Typically, raw waveform data are first read out from the arrays using one of these techniques and then stored on computer hard drives for offline optimum filtering, leading not only to requirements for large storage space but also limitations on achievable count rate. Thus, a read-out module that is capable of processing microcalorimeter signals in real time will be highly desirable. We have developed multichannel digital signal processing electronics that are capable of on-board, real time processing of microcalorimeter sensor signals from multiplexed or individual pixel arrays. It is a 3U PXI module consisting of a standardized core processor board and a set of daughter boards. Each daughter board is designed to interface a specific type of microcalorimeter array to the core processor. The combination of the standardized core plus this set of easily designed and modified daughter boards results in a versatile data acquisition module that not only can easily expand to future detector systems, but is also low cost. In this paper, we first present the core processor/daughter board architecture, and then report the performance of an 8-channel daughter board, which digitizes individual pixel outputs at 1 MSPS with 16-bit precision. We will also introduce a time-division multiplexing type daughter board, which takes in time-division multiplexing signals through fiber-optic cables and then processes the digital signals to generate energy spectra in real time.
Image Processing In Laser-Beam-Steering Subsystem
NASA Technical Reports Server (NTRS)
Lesh, James R.; Ansari, Homayoon; Chen, Chien-Chung; Russell, Donald W.
1996-01-01
Conceptual design of image-processing circuitry developed for proposed tracking apparatus described in "Beam-Steering Subsystem For Laser Communication" (NPO-19069). In proposed system, desired frame rate achieved by "windowed" readout scheme in which only pixels containing and surrounding two spots read out and others skipped without being read. Image data processed rapidly and efficiently to achieve high frequency response.
DEFENSE PRODUCTION ACT: Agencies Lack Policies and Guidance for Use of Key Authorities
2008-06-01
thermal batteries $11.44 Projects under $10 million Radiation Hardened Cryogenic Read Out Integrated Circuits (ROIC) Establishment of a domestic...performance of polymers $13.73 High Performance Thermal Battery Production Initiative Establish, strengthen, and expand a domestic source for advanced
The role of knowledge structures in fault diagnosis
NASA Technical Reports Server (NTRS)
Smith, P. J.; Giffin, W. C.; Rockwell, T. H.; Thomas, M. E.
1984-01-01
The use of human memory and knowledge structures to direct fault diagnosis performance was investigated. The performances of 20 pilots with instrument flight ratings were studied in a fault diagnosis task. The pilots were read a scenario which described flight conditions under which the symptoms which are indicative of a problem were detected. They were asked to think out loud as they requested and interpreted various pieces of information to diagnose the cause of the problem. Only 11 of the 20 pilots successfully diagnosed the problem. Pilot performance on this fault diagnosis task was modeled in the use of domain specific knowledge organized in a frame system. Eighteen frames, with a common structure, were necessary to account for the data from all twenty subjects.
Swanson, H L
1999-01-01
This investigation explores the contribution of two working memory systems (the articulatory loop and the central executive) to the performance differences between learning-disabled (LD) and skilled readers. Performances of LD, chronological age (CA) matched, and reading level-matched children were compared on measures of phonological processing accuracy and speed (articulatory system), long-term memory (LTM) accuracy and speed, and executive processing. The results indicated that (a) LD readers were inferior on measures of articulatory, LTM, and executive processing; (b) LD readers were superior to RL readers on measures of executive processing, but were comparable to RL readers on measures of the articulatory and LTM system; (c) executive processing differences remained significant between LD and CA-matched children when measures of reading comprehension, articulatory processes, and LTM processes were partialed from the analysis; and (d) executive processing contributed significant variance to reading comprehension when measures of the articulatory and LTM systems were entered into a hierarchical regression model. In summary, LD readers experience constraints in the articulatory and LTM system, but constraints mediate only some of the influence of executive processing on reading comprehension. Further, LD readers suffer executive processing problems nonspecific to their reading comprehension problems. Copyright 1999 Academic Press.
Helping blind and partially sighted people to read: the effectiveness of low vision aids
Margrain, T.
2000-01-01
AIMS—To substantiate the claim that low vision aids reduce the degree of disability associated with visual impairment. METHODS—An observational study of vision, ocular pathology, age, sex, and reading ability in new referrals to a low vision clinic. Reading ability was assessed both with the patients' own spectacles and with an appropriate low vision aid. RESULTS—The reading performance and biographical characteristics of new referrals to a low vision clinic were recorded. Data were collected for 168 people over a 6 month period. Upon arrival at the clinic the mean functional visual acuity equated to 6/36 and 77% of patients were unable to read newsprint (N8). After a low vision assessment and provision of a suitable low vision aid 88% of new patients were able to read N8 or smaller text. CONCLUSIONS—The degree of visual impairment observed in new referrals to a low vision clinic is sufficient to prevent the majority from performing many daily tasks. Low vision aids are an effective means of providing visual rehabilitation, helping almost nine out of 10 patients with impaired vision to read. PMID:10906105
3D Modeling of Interior Building Environments and Objects from Noisy Sensor Suites
2015-05-14
building environments. The interior environment of a building is scanned by a custom hardware system, which provides raw laser and camera sensor readings...interior environment of a building is scanned by a custom hardware system, which provides raw laser and camera sensor readings used to develop these...seemed straight out of a Calvin & Hobbes strip . As soon as I met the people here, I immediately found that the intellectual adventure matched the
NASA Astrophysics Data System (ADS)
Niklas, M.; Zimmermann, F.; Schlegel, J.; Schwager, C.; Debus, J.; Jäkel, O.; Abdollahi, A.; Greilich, S.
2016-09-01
The hybrid technology cell-fluorescent ion track hybrid detector (Cell-Fit-HD) enables the investigation of radiation-related cellular events along single ion tracks on the subcellular scale in clinical ion beams. The Cell-Fit-HD comprises a fluorescent nuclear track detector (FNTD, the physical compartment), a device for individual particle detection and a substrate for viable cell-coating, i.e. the biological compartment. To date both compartments have been imaged sequentially in situ by confocal laser scanning microscopy (CLSM). This is yet in conflict with a functional read-out of the Cell-Fit-HD utilizing a fast live-cell imaging of the biological compartment with low phototoxicity on greater time scales. The read-out of the biological from the physical compartment was uncoupled. A read-out procedure was developed to image the cell layer by conventional widefield microscopy whereas the FNTD was imaged by CLSM. Point mapping registration of the confocal and widefield imaging data was performed. Non-fluorescent crystal defects (spinels) visible in both read-outs were used as control point pairs. The accuracy achieved was on the sub-µm scale. The read-out procedure by widefield microscopy does not impair the unique ability of spatial correlation by the Cell-Fit-HD. The uncoupling will enlarge the application potential of the hybrid technology significantly. The registration allows for an ultimate correlation of microscopic physical beam parameters and cell kinetics on greater time scales. The method reported herein will be instrumental for the introduction of a novel generation of compact detectors facilitating biodosimetric research towards high-throughput analysis.
Integrated electronics for time-resolved array of single-photon avalanche diodes
NASA Astrophysics Data System (ADS)
Acconcia, G.; Crotti, M.; Rech, I.; Ghioni, M.
2013-12-01
The Time Correlated Single Photon Counting (TCSPC) technique has reached a prominent position among analytical methods employed in a great variety of fields, from medicine and biology (fluorescence spectroscopy) to telemetry (laser ranging) and communication (quantum cryptography). Nevertheless the development of TCSPC acquisition systems featuring both a high number of parallel channels and very high performance is still an open challenge: to satisfy the tight requirements set by the applications, a fully parallel acquisition system requires not only high efficiency single photon detectors but also a read-out electronics specifically designed to obtain the highest performance in conjunction with these sensors. To this aim three main blocks have been designed: a gigahertz bandwidth front-end stage to directly read the custom technology SPAD array avalanche current, a reconfigurable logic to route the detectors output signals to the acquisition chain and an array of time measurement circuits capable of recording the photon arrival times with picoseconds time resolution and a very high linearity. An innovative architecture based on these three circuits will feature a very high number of detectors to perform a truly parallel spatial or spectral analysis and a smaller number of high performance time-to-amplitude converter offering very high performance and a very high conversion frequency while limiting the area occupation and power dissipation. The routing logic will make the dynamic connection between the two arrays possible in order to guarantee that no information gets lost.
Infantino, M; Meacci, F; Grossi, V; Manfredi, M; Benucci, M; Merone, M; Soda, P
2017-02-01
According to the recent recommendations of the American College of Rheumatology, ANA Task Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result was made if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANA-IIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readings were statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems that worked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readings were not statistically different. The change of the assay kit and/or the introduction of a CAD system affect the laboratory reporting, with an evident impact on the autoimmune laboratory workflow. The CAD systems may represent one of the most important novel elements of harmonization in the autoimmunity field, reducing intra- and inter-laboratory variability in a new vision of the diagnostic autoimmune platform.
ERIC Educational Resources Information Center
Lusk, Kelly E.
2012-01-01
This single-subject study explored the effects of different mounting systems of prescribed near magnification (handheld, stand-mounted, spectacle-mounted, and electronic) on reading performance and preference in students with low vision. Participants included five students ranging from 3rd to 11th grade, and with various etiologies. Reading…
Semi-automatic aircraft control system
NASA Technical Reports Server (NTRS)
Gilson, Richard D. (Inventor)
1978-01-01
A flight control type system which provides a tactile readout to the hand of a pilot for directing elevator control during both approach to flare-out and departure maneuvers. For altitudes above flare-out, the system sums the instantaneous coefficient of lift signals of a lift transducer with a generated signal representing ideal coefficient of lift for approach to flare-out, i.e., a value of about 30% below stall. Error signals resulting from the summation are read out by the noted tactile device. Below flare altitude, an altitude responsive variation is summed with the signal representing ideal coefficient of lift to provide error signal readout.
DIODE STEERED MANGETIC-CORE MEMORY
Melmed, A.S.; Shevlin, R.T.; Laupheimer, R.
1962-09-18
A word-arranged magnetic-core memory is designed for use in a digital computer utilizing the reverse or back current property of the semi-conductor diodes to restore the information in the memory after read-out. In order to ob tain a read-out signal from a magnetic core storage unit, it is necessary to change the states of some of the magnetic cores. In order to retain the information in the memory after read-out it is then necessary to provide a means to return the switched cores to their states before read-out. A rewrite driver passes a pulse back through each row of cores in which some switching has taken place. This pulse combines with the reverse current pulses of diodes for each column in which a core is switched during read-out to cause the particular cores to be switched back into their states prior to read-out. (AEC)
Using a Classroom Response System to Improve Multiple-Choice Performance in AP® Physics
NASA Astrophysics Data System (ADS)
Bertrand, Peggy
2009-04-01
Participation in rigorous high school courses such as Advanced Placement (AP®) Physics increases the likelihood of college success, especially for students who are traditionally underserved. Tackling difficult multiple-choice exams should be part of any AP program because well-constructed multiple-choice questions, such as those on AP exams and on the Force Concept Inventory,2 are particularly good at rooting out common and persisting student misconceptions. Additionally, there are barriers to multiple-choice performance that have little to do with content mastery. For example, a student might fail to read the question thoroughly, forget to apply a reasonableness test to the answer, or simply work too slowly.
A direct reading exposure monitor for radiation processing
NASA Astrophysics Data System (ADS)
Kantz, A. D.; Humpherys, K. C.
Various plastic films have been utilized to measure radiation fields. In general such films are rugged, easily handled, small enough to cause neligible perturbation on the radiation fields, and relatively inexpensive. The radiachromic materials have been shown to have advantages over other plastic fabrications in stability, reproducibility, equivalent response to electron and gamma ray processing fields, dose rate independence, and ready availability of calibration standards. Using a nylon matrix radiachromic detector, a system of direct read-out of absorbed dose has been developed to facilitate monitoring in the megarad region. When an exposed detector is inserted into the reader, the optical transmission signal is processed through an analog to digital converter. The digitized signal addresses a memory bank where the standard response curve is stored. The corresponding absorbed dose is displayed on a digital panel meter. The variation of relative sensitivity of detectors, the background of unirradiated detectors, environmental parameters, and the capacity of the memory bank are contributing factors to the total precision of the read-out system.
Experimental Evaluation of a Braille-Reading-Inspired Finger Motion Adaptive Algorithm.
Ulusoy, Melda; Sipahi, Rifat
2016-01-01
Braille reading is a complex process involving intricate finger-motion patterns and finger-rubbing actions across Braille letters for the stimulation of appropriate nerves. Although Braille reading is performed by smoothly moving the finger from left-to-right, research shows that even fluent reading requires right-to-left movements of the finger, known as "reversal". Reversals are crucial as they not only enhance stimulation of nerves for correctly reading the letters, but they also show one to re-read the letters that were missed in the first pass. Moreover, it is known that reversals can be performed as often as in every sentence and can start at any location in a sentence. Here, we report experimental results on the feasibility of an algorithm that can render a machine to automatically adapt to reversal gestures of one's finger. Through Braille-reading-analogous tasks, the algorithm is tested with thirty sighted subjects that volunteered in the study. We find that the finger motion adaptive algorithm (FMAA) is useful in achieving cooperation between human finger and the machine. In the presence of FMAA, subjects' performance metrics associated with the tasks have significantly improved as supported by statistical analysis. In light of these encouraging results, preliminary experiments are carried out with five blind subjects with the aim to put the algorithm to test. Results obtained from carefully designed experiments showed that subjects' Braille reading accuracy in the presence of FMAA was more favorable then when FMAA was turned off. Utilization of FMAA in future generation Braille reading devices thus holds strong promise.
Experimental Evaluation of a Braille-Reading-Inspired Finger Motion Adaptive Algorithm
2016-01-01
Braille reading is a complex process involving intricate finger-motion patterns and finger-rubbing actions across Braille letters for the stimulation of appropriate nerves. Although Braille reading is performed by smoothly moving the finger from left-to-right, research shows that even fluent reading requires right-to-left movements of the finger, known as “reversal”. Reversals are crucial as they not only enhance stimulation of nerves for correctly reading the letters, but they also show one to re-read the letters that were missed in the first pass. Moreover, it is known that reversals can be performed as often as in every sentence and can start at any location in a sentence. Here, we report experimental results on the feasibility of an algorithm that can render a machine to automatically adapt to reversal gestures of one’s finger. Through Braille-reading-analogous tasks, the algorithm is tested with thirty sighted subjects that volunteered in the study. We find that the finger motion adaptive algorithm (FMAA) is useful in achieving cooperation between human finger and the machine. In the presence of FMAA, subjects’ performance metrics associated with the tasks have significantly improved as supported by statistical analysis. In light of these encouraging results, preliminary experiments are carried out with five blind subjects with the aim to put the algorithm to test. Results obtained from carefully designed experiments showed that subjects’ Braille reading accuracy in the presence of FMAA was more favorable then when FMAA was turned off. Utilization of FMAA in future generation Braille reading devices thus holds strong promise. PMID:26849058
Adaptation of the Wilson Reading System for Braille Readers
ERIC Educational Resources Information Center
Rowley, Roz; McCarthy, Mary; Rines, Justine Carlone
2014-01-01
Teachers at Perkins School for the Blind have been teaching braille to students of all ages for many years. As part of this experience, the teachers at Perkins have seen many capable students of different ages struggle to learn to read and write braille. In particular, they observed students who were unable to sound out or decode words because of…
A pixel read-out architecture implementing a two-stage token ring, zero suppression and compression
NASA Astrophysics Data System (ADS)
Heuvelmans, S.; Boerrigter, M.
2011-01-01
Increasing luminosity in high energy physics experiments leads to new challenges in the design of data acquisition systems for pixel detectors. With the upgrade of the LHCb experiment, the data processing will be changed; hit data from every collision will be transported off the pixel chip, without any trigger selection. A read-out architecture is proposed which is able to obtain low hit data loss on limited silicon area by using the logic beneath the pixels as a data buffer. Zero suppression and redundancy reduction ensure that the data rate off chip is minimized. A C++ model has been created for simulation of functionality and data loss, and for system development. A VHDL implementation has been derived from this model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bush, K; Freeman, J; Zavalkovskiy, B
Purpose: Situated 20 miles from 5 major fault lines in California’s Bay Area, Stanford Universityhas a critical need for IT infrastructure planning to handle the high probability devastating earthquakes. Recently, a multi-million dollar project has been underway to overhaul Stanford’s radiation oncology information systems, maximizing planning system performance and providing true disaster recovery abilities. An overview of the project will be given with particular focus on lessons learned throughout the build. Methods: In this implementation, two isolated external datacenters provide geographical redundancy to Stanford’s main campus datacenter. Real-time mirroring is made of all data stored to our serial attached networkmore » (SAN) storage. In each datacenter, hardware/software virtualization was heavily implemented to maximize server efficiency and provide a robust mechanism to seamlessly migrate users in the event of an earthquake. System performance is routinely assessed through the use of virtualized data robots, able to log in to the system at scheduled times, perform routine planning tasks and report timing results to a performance dashboard. A substantial dose calculation framework (608 CPU cores) has been constructed as part of the implementation. Results: Migration to a virtualized server environment with a high performance SAN has resulted in up to a 45% speed up of common treatment planning tasks. Switching to a 608 core DCF has resulted in a 280% speed increase in dose calculations. Server tuning was found to further improved read/write performance by 20%. Disaster recovery tests are carried out quarterly and, although successful, remain time consuming to perform and verify functionality. Conclusion: Achieving true disaster recovery capabilities is possible through server virtualization, support from skilled IT staff and leadership. Substantial performance improvements are also achievable through careful tuning of server resources and disk read/write operations. Developing a streamlined method to comprehensively test failover is a key requirement to the system’s success.« less
Open Microphone Speech Understanding: Correct Discrimination Of In Domain Speech
NASA Technical Reports Server (NTRS)
Hieronymus, James; Aist, Greg; Dowding, John
2006-01-01
An ideal spoken dialogue system listens continually and determines which utterances were spoken to it, understands them and responds appropriately while ignoring the rest This paper outlines a simple method for achieving this goal which involves trading a slightly higher false rejection rate of in domain utterances for a higher correct rejection rate of Out of Domain (OOD) utterances. The system recognizes semantic entities specified by a unification grammar which is specialized by Explanation Based Learning (EBL). so that it only uses rules which are seen in the training data. The resulting grammar has probabilities assigned to each construct so that overgeneralizations are not a problem. The resulting system only recognizes utterances which reduce to a valid logical form which has meaning for the system and rejects the rest. A class N-gram grammar has been trained on the same training data. This system gives good recognition performance and offers good Out of Domain discrimination when combined with the semantic analysis. The resulting systems were tested on a Space Station Robot Dialogue Speech Database and a subset of the OGI conversational speech database. Both systems run in real time on a PC laptop and the present performance allows continuous listening with an acceptably low false acceptance rate. This type of open microphone system has been used in the Clarissa procedure reading and navigation spoken dialogue system which is being tested on the International Space Station.
Prototyping the E-ELT M1 local control system communication infrastructure
NASA Astrophysics Data System (ADS)
Argomedo, J.; Kornweibel, N.; Grudzien, T.; Dimmler, M.; Andolfato, L.; Barriga, P.
2016-08-01
The primary mirror of the E-ELT is composed of 798 hexagonal segments of about 1.45 meters across. Each segment can be moved in piston and tip-tilt using three position actuators. Inductive edge sensors are used to provide feedback for global reconstruction of the mirror shape. The E-ELT M1 Local Control System will provide a deterministic infrastructure for collecting edge sensor and actuators readings and distribute the new position actuators references while at the same time providing failure detection, isolation and notification, synchronization, monitoring and configuration management. The present paper describes the prototyping activities carried out to verify the feasibility of the E-ELT M1 local control system communication architecture design and assess its performance and potential limitations.
Ma, Lin; Xu, Yubin
2015-01-01
Green WLAN is a promising technique for accessing future indoor Internet services. It is designed not only for high-speed data communication purposes but also for energy efficiency. The basic strategy of green WLAN is that all the access points are not always powered on, but rather work on-demand. Though powering off idle access points does not affect data communication, a serious asymmetric matching problem will arise in a WLAN indoor positioning system due to the fact the received signal strength (RSS) readings from the available access points are different in their offline and online phases. This asymmetry problem will no doubt invalidate the fingerprint algorithm used to estimate the mobile device location. Therefore, in this paper we propose a green WLAN indoor positioning system, which can recover RSS readings and achieve good localization performance based on singular value thresholding (SVT) theory. By solving the nuclear norm minimization problem, SVT recovers not only the radio map, but also online RSS readings from a sparse matrix by sensing only a fraction of the RSS readings. We have implemented the method in our lab and evaluated its performances. The experimental results indicate the proposed system could recover the RSS readings and achieve good localization performance. PMID:25587977
User questionnaire to evaluate the radiological workspace.
van Ooijen, Peter M A; Koesoema, Allya P; Oudkerk, Matthijs
2006-01-01
Over the past few years, an increase in digitalization of radiology departments can be seen, which has a large impact on the work of the radiologists. This impact is not only demonstrated by the increased use of digital images but also by changing demands on the whole reading environment. In this study, we evaluated the satisfaction of our radiologists with our digital Picture Archival and Communication System environment and their workspace. This evaluation was performed by distribution of a questionnaire consisting of a score sheet and some open questions to all radiologists and residents. Out of 25 questionnaires, 12 were adequately answered and returned. Results clearly showed that most problems were present in the area of reading room design and layout and comfort and ergonomics. Based on the results from this study, adaptations were made and the results were also used in the planning of the redesign of the entire department of radiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellefson, S; Department of Human Oncology, University of Wisconsin, Madison, WI; Culberson, W
Purpose: Discrepancies in absolute dose values have been detected between the ViewRay treatment planning system and ArcCHECK readings when performing delivery quality assurance on the ViewRay system with the ArcCHECK-MR diode array (SunNuclear Corporation). In this work, we investigate whether these discrepancies are due to errors in the ViewRay planning and/or delivery system or due to errors in the ArcCHECK’s readings. Methods: Gamma analysis was performed on 19 ViewRay patient plans using the ArcCHECK. Frequency analysis on the dose differences was performed. To investigate whether discrepancies were due to measurement or delivery error, 10 diodes in low-gradient dose regions weremore » chosen to compare with ion chamber measurements in a PMMA phantom with the same size and shape as the ArcCHECK, provided by SunNuclear. The diodes chosen all had significant discrepancies in absolute dose values compared to the ViewRay TPS. Absolute doses to PMMA were compared between the ViewRay TPS calculations, ArcCHECK measurements, and measurements in the PMMA phantom. Results: Three of the 19 patient plans had 3%/3mm gamma passing rates less than 95%, and ten of the 19 plans had 2%/2mm passing rates less than 95%. Frequency analysis implied a non-random error process. Out of the 10 diode locations measured, ion chamber measurements were all within 2.2% error relative to the TPS and had a mean error of 1.2%. ArcCHECK measurements ranged from 4.5% to over 15% error relative to the TPS and had a mean error of 8.0%. Conclusion: The ArcCHECK performs well for quality assurance on the ViewRay under most circumstances. However, under certain conditions the absolute dose readings are significantly higher compared to the planned doses. As the ion chamber measurements consistently agree with the TPS, it can be concluded that the discrepancies are due to ArcCHECK measurement error and not TPS or delivery system error. This work was funded by the Bhudatt Paliwal Professorship and the University of Wisconsin Medical Radiation Research Center.« less
ERIC Educational Resources Information Center
Silinskas, Gintautas; Kiuru, Noona; Aunola, Kaisa; Lerkkanen, Marja-Kristiina; Nurmi, Jari-Erik
2015-01-01
This study investigated the longitudinal associations between children's academic performance and their mothers' affect, practices, and perceptions of their children in homework situations. The children's (n = 2,261) performance in reading and math was tested in Grade 1 and Grade 4, and the mothers (n = 1,476) filled out questionnaires on their…
Motivating Low Performing Adolescent Readers. ERIC Digest.
ERIC Educational Resources Information Center
Collins, Norma Decker
This Digest focuses on motivating the low performing adolescent in a remedial reading or subject area classroom--the idea is that students who are disengaged from their own learning processes are not likely to perform well in school. The Digest points out that such adolescents are often caught in a cycle of failure and that secondary teachers must…
Reading in Class & out of Class: An Experience Sampling Method Study
ERIC Educational Resources Information Center
Shumow, Lee; Schmidt, Jennifer A.; Kackar, Hayal
2008-01-01
This study described and compared the reading of sixth and eighth grade students both in and out of school using a unique data set collected with the Experience Sampling Method (ESM). On average, students read forty minutes a day out of class and seventeen minutes a day in class indicating that reading is a common leisure practice for…
Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research
NASA Astrophysics Data System (ADS)
Bergeron, Mélanie; Cadorette, Jules; Tétrault, Marc-André; Beaudoin, Jean-François; Leroux, Jean-Daniel; Fontaine, Réjean; Lecomte, Roger
2014-02-01
The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm3), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250-650 keV) and a high-resolution mode (350-650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250-650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250-650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml-1. With the same phantom, the scatter fraction for all scanners is about 17% for an energy threshold of 250 keV and 10% for an energy threshold of 350 keV. The results obtained with two energy window settings confirm the relevance of high-efficiency and high-resolution operating modes to take full advantage of the imaging capabilities of the LabPET scanners for molecular imaging applications.
ERIC Educational Resources Information Center
Instituto Nacional de Pedagogia (Mexico).
This document is an English-language abstract (approximately 1,500 words) of experiments performed in Mexico, D. F. by way of introducing new techniques for teaching reading and writing, particularly in the remedial classes. The first part of the document deals with a series of experiments carried out with first grade remedial groups as follows:…
The TOFp/pVPD time-of-flight system for STAR
NASA Astrophysics Data System (ADS)
Llope, W. J.; Geurts, F.; Mitchell, J. W.; Liu, Z.; Adams, N.; Eppley, G.; Keane, D.; Li, J.; Liu, F.; Liu, L.; Mutchler, G. S.; Nussbaum, T.; Bonner, B.; Sappenfield, P.; Zhang, B.; Zhang, W.-M.
2004-04-01
A time-of-flight system was constructed for the STAR Experiment for the direct identification of hadrons produced in 197Au+ 197Au collisions at RHIC. The system consists of two separate detector subsystems, one called the Pseudo Vertex Position Detector (pVPD, the "start" detector) and the other called the Time of Flight Patch (TOFp, the "stop" detector). Each detector is based on conventional scintillator/phototube technology and includes custom high-performance front-end electronics and a common CAMAC-based digitization and read-out. The design of the system and its performance during the 2001 RHIC run will be described. The start resolution attained by the pVPD was 24 ps, implying a pVPD single-detector resolution of 58 ps. The total time resolution of the system averaged over all detector channels was 87 ps, allowing direct π/ K/ p discrimination for momenta up to ˜1.8 GeV/ c, and direct ( π+ K)/ p discrimination up to ˜3 GeV/ c.
NASA Astrophysics Data System (ADS)
Krejci, F.; Zemlicka, J.; Jakubek, J.; Dudak, J.; Vavrik, D.; Köster, U.; Atkins, D.; Kaestner, A.; Soltes, J.; Viererbl, L.; Vacik, J.; Tomandl, I.
2016-12-01
Using a suitable isotope such as 6Li and 10B semiconductor hybrid pixel detectors can be successfully adapted for position sensitive detection of thermal and cold neutrons via conversion into energetic light ions. The adapted devices then typically provides spatial resolution at the level comparable to the pixel pitch (55 μm) and sensitive area of about few cm2. In this contribution, we describe further progress in neutron imaging performance based on the development of a large-area hybrid pixel detector providing practically continuous neutron sensitive area of 71 × 57 mm2. The measurements characterising the detector performance at the cold neutron imaging instrument ICON at PSI and high-flux imaging beam-line Neutrograph at ILL are presented. At both facilities, high-resolution high-contrast neutron radiography with the newly developed detector has been successfully applied for objects which imaging were previously difficult with hybrid pixel technology (such as various composite materials, objects of cultural heritage etc.). Further, a significant improvement in the spatial resolution of neutron radiography with hybrid semiconductor pixel detector based on the fast read-out Timepix-based detector is presented. The system is equipped with a thin planar 6LiF convertor operated effectively in the event-by-event mode enabling position sensitive detection with spatial resolution better than 10 μm.
Two-dimensional photon-counting detector arrays based on microchannel array plates
NASA Technical Reports Server (NTRS)
Timothy, J. G.; Bybee, R. L.
1975-01-01
The production of simple and rugged photon-counting detector arrays has been made possible by recent improvements in the performance of the microchannel array plate (MCP) and by the parallel development of compatible electronic readout systems. The construction of proximity-focused MCP arrays of novel design in which photometric information from (n x m) picture elements is read out with a total of (n + m) amplifier and discriminator circuits is described. Results obtained with a breadboard (32 x 32)-element array employing 64 charge-sensitive amplifiers are presented, and the application of systems of this type in spectrometers and cameras for use with ground-based telescopes and on orbiting spacecraft discussed.
QWIPs at IRnova, a status update
NASA Astrophysics Data System (ADS)
Martijn, Henk; Gamfeldt, Anders; Asplund, Carl; Smuk, Sergiy; Kataria, Himanshu; Costard, Eric
2016-05-01
IRnova has a long history of producing QWIPs for the LWIR band. In this paper we give an overview of the current products (FPAs with 640x480 and 384x288 pixels respectively, and 25 μm pitch) and their performance. Their superior stability and uniformity inherent to detectors based on III/V material system will be demonstrated. Furthermore, an IDCA specifically designed for hand-held systems used for the detection of SF6 gas using a 0.5 W cooler will be presented. The detector format is 320x256 pixels with 30 μm pitch using the ISC9705 read out circuit. The peak wavelength is at 10.55 μm and the NETD is 22 mK.
High rate tests of the photon detection system for the LHCb RICH Upgrade
NASA Astrophysics Data System (ADS)
Blago, M. P.; Keizer, F.
2017-12-01
The photon detection system for the LHCb RICH Upgrade consists of an array of multianode photomultiplier tubes (MaPMTs) read out by custom-built modular electronics. The behaviour of the whole chain was studied at CERN using a pulsed laser. Threshold scans were performed in order to study the MaPMT pulse-height spectra at high event rates and different photon intensities. The results show a reduction in photon detection efficiency at 900 V bias voltage, marked by a 20% decrease in the single-photon peak height, when increasing the event rate from 100 kHz to 20 MHz. This reduction was not observed at 1000 V bias voltage.
Tips for Supporting Reading Skills at Home
ERIC Educational Resources Information Center
What Works Clearinghouse, 2018
2018-01-01
This document provides the following four tips for supporting reading skills for children ages K-3 at home: (1) Have conversations before, during, and after reading together; (2) Help children learn how to break sentences; (3) Help children sound out words smoothly; and (4) Model reading fluently by practicing reading out loud with your child.…
Adolescents' Out-of-School Digital Reading Practices
ERIC Educational Resources Information Center
Zucker, Lauren
2018-01-01
Adolescents spend a significant portion of the day on digital devices, yet we know very little about their out-of-school reading practices. While screen recording technology allows researchers to record and view videos of digital reading, the majority of studies exploring digital reading limit participants' reading to researcher-selected texts and…
Morphological and syntactic awareness in poor comprehenders: another piece of the puzzle.
Tong, Xiuli; Deacon, S Hélène; Cain, Kate
2014-01-01
Poor comprehenders have intact word-reading skills but struggle specifically with understanding what they read. We investigated whether two metalinguistic skills, morphological and syntactic awareness, are specifically related to poor reading comprehension by including separate and combined measures of each. We identified poor comprehenders (n = 15) and average comprehenders (n = 15) in Grade 4 who were matched on word-reading accuracy and speed, vocabulary, nonverbal cognitive ability, and age. The two groups performed comparably on a morphological awareness task that involved both morphological and syntactic cues. However, poor comprehenders performed less well than average comprehenders on a derivational word analogy task in which there was no additional syntactic information, thus tapping only morphological awareness, and also less well on a syntactic awareness task, in which there were no morphological manipulations. Our task and participant-selection process ruled out key nonmetalinguistic sources of influence on these tasks. These findings suggest that the relationships among reading comprehension, morphological awareness, and syntactic awareness depend on the tasks used to measure the latter two. Future research needs to identify precisely in which ways these metalinguistic difficulties connect to challenges with reading comprehension.
Description and Validation of a Test to Evaluate Sustained Silent Reading
Ramulu, Pradeep Y.; Swenor, Bonnielin K.; Jefferys, Joan L.; Rubin, Gary S.
2013-01-01
Purpose. To construct and validate a test of sustained silent reading. Methods. Standardized 7300 and 7600 word passages were written to evaluate sustained silent reading. Two hundred forty subjects validated whether comprehension questions could discriminate subjects who did and did not read the passage. To evaluate test–retest properties, 49 subjects silently read the standardized passages on separate days. Sixty glaucoma suspect controls and 64 glaucoma subjects had their out loud reading evaluated with the MNRead card and an International Reading Speed Texts (IReST) passage, and their silent reading measured using the 7300 word passage. Sustained silent reading parameters included reading speed and reading speed slope over time. Results. Comprehension questions distinguished individuals who had and had not read passage materials. Bland-Altman analyses of intersession sustained reading speed and reading speed slope demonstrated 95% coefficients of repeatability of 57 words per minute (wpm) and 2.76 wpm/minute. Sustained silent reading speed was less correlated with MNRead (r = 0.59) or IReST passage (r = 0.68) reading speeds than the correlation of these two measures of out loud reading speed with each other (r = 0.72). Sustained silent reading speed was more likely to differ from IReST reading speed by more than 50% in rapid silent readers (odds ratio [OR] = 29, 95% confidence interval [CI] = 10–87), and comparisons of sustained and out loud reading speeds demonstrated proportional error in Bland-Altman analyses. Conclusions. Tests of out loud reading do not accurately reflect silent reading speed in individuals with normal vision or glaucoma. The described test offers a standardized way to evaluate the impact of eye disease and/or visual rehabilitation on sustained silent reading. PMID:23258146
Abou-Dakn, M; Döhmen, C; Wenzel, S
2017-02-01
The present study aims to examine the performance of the TONOPORT VI ambulatory blood pressure (BP) monitor in the inflation and deflation measurement methods, according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP 2010). Systolic and diastolic blood pressures (SBP and DBP, respectively) of 33 subjects (23 female, 10 male) were sequentially measured and compared with reference measurements obtained by two observers using a standard mercury sphygmomanometer. The subjects were selected according to the recruitment instructions of the ESH-IP 2010. Three comparative readings were performed per subject. Among the 99 readings in the inflation measurement method were 92/94 (SBP/DBP) with differences ⩽5, 97/99 ⩽10 and 98/99 ⩽15 mm Hg. All of the 33 subjects had at least 2 out of 3 comparative readings with differences ⩽5 mm Hg and 0/0 of the subjects had no reading ⩽15 mm Hg. The validation of the deflation measurement method resulted in differences where 93/91 were ⩽5, 98/98 were ⩽10, and 99/99 were ⩽15 mm Hg. Thirty-two of the 33 subjects had at least 2 out of 3 comparative readings ⩽5 mm Hg and 0/0 of the subjects had no reading ⩽15 mm Hg. In conclusion, the TONOPORT VI, respectively, in the inflation and deflation measurement methods met all requirements of Part 1 and 2 of the ESH-IP 2010. Based on the study results, the TONOPORT VI can be recommended for BP measurements in adults.
Whitford, Veronica; Joanisse, Marc F
2018-09-01
An extensive body of research has examined reading acquisition and performance in monolingual children. Surprisingly, however, much less is known about reading in bilingual children, who outnumber monolingual children globally. Here, we address this important imbalance in the literature by employing eye movement recordings to examine both global (i.e., text-level) and local (i.e., word-level) aspects of monolingual and bilingual children's reading performance across their first-language (L1) and second-language (L2). We also had a specific focus on lexical accessibility, indexed by word frequency effects. We had three main findings. First, bilingual children displayed reduced global and local L1 reading performance relative to monolingual children, including larger L1 word frequency effects. Second, bilingual children displayed reduced global and local L2 versus L1 reading performance, including larger L2 word frequency effects. Third, both groups of children displayed reduced global and local reading performance relative to adult comparison groups (across their known languages), including larger word frequency effects. Notably, our first finding was not captured by traditional offline measures of reading, such as standardized tests, suggesting that these measures may lack the sensitivity to detect such nuanced between-group differences in reading performance. Taken together, our findings demonstrate that bilingual children's simultaneous exposure to two reading systems leads to eye movement reading behavior that differs from that of monolingual children and has important consequences for how lexical information is accessed and integrated in both languages. Copyright © 2018 Elsevier Inc. All rights reserved.
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
Large Format, Background Limited Arrays of Kinetic Inductance Detectors for Sub-mm Astronomy
NASA Astrophysics Data System (ADS)
Baselmans, Jochem
2018-01-01
We present the development of large format imaging arrays for sub-mm astronomy based upon microwave Kinetic Inductance detectors and their read-out. In particular we focus on the arrays developed for the A-MKID instrument for the APEX telescope. AMKID contains 2 focal plane arrays, covering a field of view of 15?x15?. One array is optimized for the 350 GHz telluric window, the other for the 850 GHz window. Both arrays are constructed from four 61 x 61 mm detector chips, each of which contains up to 3400 detectors and up to 880 detectors per readout line. The detectors are lens antenna coupled MKIDs made from NbTiN and Aluminium that reach photon noise limited sensitivity in combination with a high optical coupling. The lens-antenna radiation coupling enables the use of 4K optics and Lyot stop due to the intrinsic directivity of the detector beam, allowing a simple cryogenic architecture. We discuss the pixel design and verification, detector packaging and the array performance. We will also discuss the readout system, which is a combination of a digital and analog back-end that can read-out up to 4000 pixels simultaneously using frequency division multiplexing.
NASA Technical Reports Server (NTRS)
Yoon, Wonsik; Adams, Joseph S.; Bandler, Simon R.; Chervenak, James A.; Datesman, Aaron M.; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.; Miniussi, Antoine R.;
2017-01-01
We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.
A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters
NASA Astrophysics Data System (ADS)
Rost, A.; Galatyuk, T.; Koenig, W.; Michel, J.; Pietraszko, J.; Skott, P.; Traxler, M.
2017-02-01
A Charge-to-Digital-Converter (QDC) and Time-to-Digital-Converter (TDC) based on a commercial FPGA (Field Programmable Gate Array) was developed to read out PMT signals of the planned HADES electromagnetic calorimeter (ECAL) at GSI Helmholtzzentrum für Schwerionenforschung GmbH (Darmstadt, Germany). The main idea is to convert the charge measurement of a detector signal into a time measurement, where the charge is encoded in the width of a digital pulse, while the arrival time information is encoded in the leading edge time of the pulse. The PaDiWa-AMPS prototype front-end board for the TRB3 (General Purpose Trigger and Readout Board—version 3) which implements this conversion method was developed and qualified. The already well established TRB3 platform provides the needed precise time measurements and serves as a data acquisition system. We present the read-out concept and the performance of the prototype boards in laboratory and also under beam conditions. First steps have been completed in order to adapt this concept to SiPM signals of the hadron calorimeter in the CBM experiment at the planned FAIR facility (Darmstadt).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiuchi, Kenji; et al.
We proposed a new high-resolution single-photon infrared spectrometer for search for radiative decay of cosmic neutrino background (CνB). The superconducting-tunnel-junctions(STJs) are used as a single-photon counting device. Each STJ consists of Nb/Al/Al xO y/Al/Nb layers, and their thicknesses are optimized for the operation temperature at 370 mK cooled by a 3He sorption refrigerator. Our STJs achieved the leak current 250 pA, and the measured data implies that a smaller area STJ fulfills our requirement. FD-SOI MOSFETs are employed to amplify the STJ signal current in order to increase signal-to-noise ratio (S/N). FD-SOI MOSFETs can be operated at cryogenic temperature ofmore » 370 mK, which reduces the noise of the signal amplification system. FD-SOI MOSFET characteristics are measured at cryogenic temperature. The Id-Vgs curve shows a sharper turn on with a higher threshold voltage and the Id-Vds curve shows a nonlinear shape in linear region at cryogenic temperature. Taking into account these effects, FD-SOI MOSFETs are available for read-out circuit of STJ detectors. The bias voltage for STJ detectors is 0.4 mV, and it must be well stabilized to deliver high performance. We proposed an FD-SOI MOSFET-based charge integrated amplifier design as a read-out circuit of STJ detectors. The requirements for an operational amplifier used in the amplifier is estimated using SPICE simulation. The op-amp is required to have a fast response (GBW ≥ 100 MHz), and it must have low power dissipation as compared to the cooling power of refrigerator.« less
Santos, Juliana Feitosa dos; Souza, Ana Paula Ramos de; Seligman, Lilian
2013-01-01
To analyze the possible relationships between high sound pressure levels in the classroom and performance in the use of lexical and phonological routes in reading and writing. This consisted on a quantitative and exploratory study. The following measures were carried out: acoustic measurement, using the dosimeter, visual inspection of the external auditory canal, tonal audiometry thresholds, speech recognition tests and acoustic immittance; instrument for evaluation of reading and writing of isolated words. The non-parametric χ² test and Fisher's exact test were used for data analysis. The results of acoustic measurements in 4 schools in Santa Maria divided the sample of 87 children of third and fourth years of primary school, aged 8 to 10 years, in 2 groups. The 1st group was exposed to sound levels higher than 80 dB(A) (Study group) and the 2nd group at levels lower than 80 dB(A) (Control group). Higher prevalence of correct answers in reading and writing of nonwords, reading irregular words and frequency effect were observed. Predominance of correct answers in the writing of irregular words was observed in the Control group. For the Study group, a higher number of type errors neologism in reading and writing were observed, especially regarding the writing of nonwords and the extension effect; fewer errors of lexicalization type and verbal paragraphy in writing were observed. In assessing the reading and writing skills, children in the Study group exposed to high noise levels had poorer performance in the use of lexical and phonological routes, both in reading and in writing.
Parent-child picture-book reading, mothers' mental state language and children's theory of mind.
Adrian, Juan E; Clemente, Rosa A; Villanueva, Lidon; Rieffe, Carolien
2005-08-01
This study focuses on parent-child book reading and its connection to the development of a theory of mind. First, parents were asked to report about frequency of parent-child storybook reading at home. Second, mothers were asked to read four picture-books to thirty-four children between 4;0 and 5;0. Both frequency of parent-child storybook reading at home, and mother's use of mental state terms in picture-books reading tasks were significantly associated with success on false belief tasks, after partialling out a number of potential mediators such as age of children, verbal IQ, paternal education, and words used by mothers in joint picture-book reading. Among the different mental state references (cognitive terms, desires, emotions and perceptions), it was found that the frequency and variety of cognitive terms, but also the frequency of emotional terms correlated positively with children's false belief performance. Relationships between mental state language and theory of mind are discussed.
Multidimensional quantitative analysis of mRNA expression within intact vertebrate embryos.
Trivedi, Vikas; Choi, Harry M T; Fraser, Scott E; Pierce, Niles A
2018-01-08
For decades, in situ hybridization methods have been essential tools for studies of vertebrate development and disease, as they enable qualitative analyses of mRNA expression in an anatomical context. Quantitative mRNA analyses typically sacrifice the anatomy, relying on embryo microdissection, dissociation, cell sorting and/or homogenization. Here, we eliminate the trade-off between quantitation and anatomical context, using quantitative in situ hybridization chain reaction (qHCR) to perform accurate and precise relative quantitation of mRNA expression with subcellular resolution within whole-mount vertebrate embryos. Gene expression can be queried in two directions: read-out from anatomical space to expression space reveals co-expression relationships in selected regions of the specimen; conversely, read-in from multidimensional expression space to anatomical space reveals those anatomical locations in which selected gene co-expression relationships occur. As we demonstrate by examining gene circuits underlying somitogenesis, quantitative read-out and read-in analyses provide the strengths of flow cytometry expression analyses, but by preserving subcellular anatomical context, they enable bi-directional queries that open a new era for in situ hybridization. © 2018. Published by The Company of Biologists Ltd.
Andover's Individualized Reading System (AIRS).
ERIC Educational Resources Information Center
Andover Public Schools, MA.
One of the twelve exemplary programs summarized in the Introduction to Right to Read's "Effective Reading Programs: Summaries of 222 Selected Programs" (CS001934), this program is designed for the elementary school children of Andover, Massachusetts. These children are from high-income families and usually perform well in school. The…
ERIC Educational Resources Information Center
Gagne, Jean-Pierre; Laplante-Levesque, Ariane; Labelle, Maude; Doucet, Katrine; Potvin, Marie-Christine
2006-01-01
A program designed to evaluate the benefits of an audiovisual-frequency modulated (FM) system led to some questions concerning the effects of illumination level and a talker's skin color on speech-reading performance. To address those issues, the speech of a Caucasian female was videotaped under 2 conditions: a light skin color condition and a…
Performance of GEM Detectors in the DarkLight Experiment at LERF
NASA Astrophysics Data System (ADS)
Mohammed Prem Nazeer, Sahara Jesmin; DarkLight Collaboration
2017-01-01
The DarkLight experiment has been proposed to search for a heavy photon A' in the mass range of 10-100 MeV/c2 produced in electron-proton collisions. Phase-I of DarkLight has started to take place in 2016 at the Low Energy Recirculator Facility (LERF) at Jefferson Lab. LERF delivered a 100 MeV electron beam onto a windowless hydrogen gas target. The phase-I detector tracks leptons inside the DarkLight solenoid with a set of Gas Electron Multiplier (GEM) detectors, combined with segmented scintillators for triggering. The GEM telescope consists of four 10 × 10 cm2 triple layer GEM chambers with 2D readout strips, mounted in a slightly angled fixed frame about 12 cm tall. The GEM data are read out with analog pipeline front-end cards (APV-25) each of which can process 128 readout channels. Each GEM chamber has 250 channels for each coordinate axis, read out with two APVs on each side, resulting in 2000 readout channels for the GEM stack, processed by 16 APVs. One Multi Purpose Digitizer (MPD) module is used to read out all of the 16 APV-25 cards. The current run status of DarkLight experiment and the performance of GEMs in the experiment will be discussed. This work has been supported by NSF PHY-1436680 and PHY-1505934.
SiGe HBT cryogenic preamplification for higher bandwidth donor spin read-out
NASA Astrophysics Data System (ADS)
Curry, Matthew; Carr, Stephen; Ten-Eyck, Greg; Wendt, Joel; Pluym, Tammy; Lilly, Michael; Carroll, Malcolm
2014-03-01
Single-shot read-out of a donor spin can be performed using the response of a single-electron-transistor (SET). This technique can produce relatively large changes in current, on the order of 1 (nA), to distinguish between the spin states. Despite the relatively large signal, the read-out time resolution has been limited to approximately 100 (kHz) of bandwidth because of noise. Cryogenic pre-amplification has been shown to extend the response of certain detection circuits to shorter time resolution and thus higher bandwidth. We examine a SiGe HBT circuit configuration for cryogenic preamplification, which has potential advantages over commonly used HEMT configurations. Here we present 4 (K) measurements of a circuit consisting of a Silicon-SET inline with a Heterojunction-Bipolar-Transistor (HBT). We compare the measured bandwidth with and without the HBT inline and find that at higher frequencies the signal-to-noise-ratio (SNR) with the HBT inline exceeds the SNR without the HBT inline. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE, Office of Basic Energy Sciences user facility. The work was supported by the Sandia National Laboratories Directed Research and Development Program. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.
Adapted shared reading at school for minimally verbal students with autism.
Mucchetti, Charlotte A
2013-05-01
Almost nothing is known about the capacity of minimally verbal students with autism to develop literacy skills. Shared reading is a regular practice in early education settings and is widely thought to encourage language and literacy development. There is some evidence that children with severe disabilities can be engaged in adapted shared reading activities. The current study examines the impact of teacher-led adapted shared reading activities on engagement and story comprehension in minimally verbal 5-6-year-old children with autism using a multiple baseline/alternating treatment design. Four students and three teachers participated. Teachers conducted adapted shared reading activities with modified books (visual supports, three-dimensional objects, simplified text) and used specific strategies for increasing student engagement. Student performance during adapted activities was compared to performance during standard shared reading sessions. All four students showed increased story comprehension and engagement during adapted shared reading. Average percentage of session engaged was 87%-100% during adapted sessions, compared with 41%-52% during baseline. Average number of correct responses to story comprehension questions was 4.2-4.8 out of 6 during adapted sessions compared with 1.2-2 during baseline. Visual supports, tactile objects, and specific teaching strategies offer ways for minimally verbal students to meaningfully participate in literacy activities. Future research should investigate adapted shared reading activities implemented classroom-wide as well as joint engagement, language, and literacy outcomes after using such activities over time.
Medical Device for Automated Prick Test Reading.
Justo, Xabier; Diaz, Inaki; Gil, Jorge Juan; Gastaminza, Gabriel
2018-05-01
Allergy tests are routinely performed in most hospitals everyday. However, measuring the outcomes of these tests is still a very laborious manual task. Current methods and systems lack of precision and repeatability. This paper presents a novel mechatronic system that is able to scan a patient's entire arm and provide allergists with precise measures of wheals for diagnosis. The device is based on 3-D laser technology and specific algorithms have been developed to process the information gathered. This system aims to automate the reading of skin prick tests and make gains in speed, accuracy, and reliability. Several experiments have been performed to evaluate the performance of the system.
NASA Technical Reports Server (NTRS)
Rauscher, Bernard J.; Arendt, Richard G.; Fixsen, D. J.; Lander, Matthew; Lindler, Don; Loose, Markus; Moseley, S. H.; Wilson, Donna V.; Xenophontos, Christos
2012-01-01
IRS2 is a Wiener-optimal approach to using all of the reference information that Teledyne's HAWAII-2RG detector arrays provide. Using a new readout pattern, IRS2 regularly interleaves reference pixels with the normal pixels during readout. This differs from conventional clocking, in which the reference pixels are read out infrequently, and only in a few rows and columns around the outside edges of the detector array. During calibration, the data are processed in Fourier space, which is <;:lose to the noise's eigenspace. Using IRS2, we have reduced the read noise of the James Webb Space Telescope Near Infrared Spectrograph by 15% compared to conventional readout. We are attempting to achieve further gains by calibrating out recently recognized non-stationary noise that appears at the frame rate.
NASA Astrophysics Data System (ADS)
Kirk, R. L.; Shepherd, M.; Sides, S. C.
2018-04-01
We use simulated images to demonstrate a novel technique for mitigating geometric distortions caused by platform motion ("jitter") as two-dimensional image sensors are exposed and read out line by line ("rolling shutter"). The results indicate that the Europa Imaging System (EIS) on NASA's Europa Clipper can likely meet its scientific goals requiring 0.1-pixel precision. We are therefore adapting the software used to demonstrate and test rolling shutter jitter correction to become part of the standard processing pipeline for EIS. The correction method will also apply to other rolling-shutter cameras, provided they have the operational flexibility to read out selected "check lines" at chosen times during the systematic readout of the frame area.
NASA Astrophysics Data System (ADS)
Radulescu, A.; Arend, N.; Drochner, M.; Ioffe, A.; Kemmerling, G.; Ossovyi, V.; Staringer, S.; Vehres, G.; McKinny, K.; Olechnowicz, B.; Yen, D.
2016-09-01
A new detection system based on an array of 3He tubes and innovative fast detection electronics was designed and produced by GE Reuter Stokes for the high-intensity small-angle neutron scattering diffractometer KWS-2, operated by the Jülich Centre for Neutron Science (JCNS) at the Heinz Meier-Leibnitz Zentrum (MLZ). The new detector consists of a panel array of 144 3He tubes and a new fast read-out electronics. The electronics is mounted in a closed case in the backside of the 3He tubes panel array and will operate at ambient atmosphere under cooling air stream. The new detection system is composed of eighteen 8-pack modules of 3He-tubes that work independently of one another (each unit has its own processor and electronics). Knowing beforehand the performance of one detector unit and of one single tube detector is prerequisite for tuning and maximizing the performance of the complete detection system. In this paper we present the results of the tests of the prototyped 8-pack of 3He-tubes and corresponding electronics, which have been carried out at the JCNS instruments KWS-2 (in high flux conditions) and TREFF.
Nature, nurture, and expertise
Plomin, Robert; Shakeshaft, Nicholas G.; McMillan, Andrew; Trzaskowski, Maciej
2014-01-01
Rather than investigating the extent to which training can improve performance under experimental conditions (‘what could be’), we ask about the origins of expertise as it exists in the world (‘what is’). We used the twin method to investigate the genetic and environmental origins of exceptional performance in reading, a skill that is a major focus of educational training in the early school years. Selecting reading experts as the top 5% from a sample of 10,000 12-year-old twins assessed on a battery of reading tests, three findings stand out. First, we found that genetic factors account for more than half of the difference in performance between expert and normal readers. Second, our results suggest that reading expertise is the quantitative extreme of the same genetic and environmental factors that affect reading performance for normal readers. Third, growing up in the same family and attending the same schools account for less than a fifth of the difference between expert and normal readers. We discuss implications and interpretations (‘what is inherited is DNA sequence variation’; ‘the abnormal is normal’). Finally, although there is no necessary relationship between ‘what is’ and ‘what could be’, the most far-reaching issues about the acquisition of expertise lie at the interface between them (‘the nature of nurture: from a passive model of imposed environments to an active model of shaped experience’). PMID:24948844
Burns, Randal; Roncal, William Gray; Kleissas, Dean; Lillaney, Kunal; Manavalan, Priya; Perlman, Eric; Berger, Daniel R; Bock, Davi D; Chung, Kwanghun; Grosenick, Logan; Kasthuri, Narayanan; Weiler, Nicholas C; Deisseroth, Karl; Kazhdan, Michael; Lichtman, Jeff; Reid, R Clay; Smith, Stephen J; Szalay, Alexander S; Vogelstein, Joshua T; Vogelstein, R Jacob
2013-01-01
We describe a scalable database cluster for the spatial analysis and annotation of high-throughput brain imaging data, initially for 3-d electron microscopy image stacks, but for time-series and multi-channel data as well. The system was designed primarily for workloads that build connectomes - neural connectivity maps of the brain-using the parallel execution of computer vision algorithms on high-performance compute clusters. These services and open-science data sets are publicly available at openconnecto.me. The system design inherits much from NoSQL scale-out and data-intensive computing architectures. We distribute data to cluster nodes by partitioning a spatial index. We direct I/O to different systems-reads to parallel disk arrays and writes to solid-state storage-to avoid I/O interference and maximize throughput. All programming interfaces are RESTful Web services, which are simple and stateless, improving scalability and usability. We include a performance evaluation of the production system, highlighting the effec-tiveness of spatial data organization.
Difficulty with Out-Loud and Silent Reading in Glaucoma
Ramulu, Pradeep Y.; Swenor, Bonnielin K.; Jefferys, Joan L.; Friedman, David S.; Rubin, Gary S.
2013-01-01
Purpose. We evaluated the impact of glaucoma on out-loud and silent reading. Methods. Glaucoma patients with bilateral visual field (VF) loss and normally-sighted controls had the following parameters measured: speed reading an International Reading Speed Text (IReST) passage out loud, maximum out-loud MNRead chart reading speed, sustained (30 minutes) silent reading speed, and change in reading speed during sustained silent reading. Results. Glaucoma subjects read slower than controls on the IReST (147 vs. 163 words per minute [wpm], P < 0.001), MNRead (172 vs. 186 wpm, P < 0.001), and sustained silent (179 vs. 218 wpm, P < 0.001) tests. In multivariable analyses adjusting for age, race, sex, education, employment, and cognition, IReST and MNRead reading speeds were 12 wpm (6%–7%) slower among glaucoma subjects compared to controls (P < 0.01 for both), while sustained silent reading speed was 16% slower (95% confidence interval [CI] = −24 to −6%, P = 0.002). Each 5 decibel (dB) decrement in better-eye VF mean deviation was associated with 6 wpm slower IReST reading (95% CI = −9 to −3%, P < 0.001), 5 wpm slower MNRead reading (95% CI = −7 to −2%, P < 0.001), and 9% slower sustained silent reading (95% CI = −13 to −6%, P < 0.001). A reading speed decline of 0.5 wpm/min or more over the sustained silent reading period was more common among glaucoma subjects than controls (odds ratio [OR] = 2.2, 95% CI = 1.0–4.9, P < 0.05). Conclusions. Reading speed is slower among glaucoma patients with bilateral VF loss, with the greatest impact present during sustained silent reading. Persons with glaucoma fatigue during silent reading, resulting in slower reading over time. PMID:23074207
The Silicon Tracking System of the CBM experiment at FAIR
NASA Astrophysics Data System (ADS)
Teklishyn, Maksym
2018-03-01
The Silicon Tracking System (STS) is the central detector in the Compressed Baryonic Matter (CBM) experiment at FAIR. Operating in the 1Tm dipole magnetic field, the STS will enable pile-up free detection and momentum measurement of the charged particles originating from beam-target nuclear interactions at rates up to 10 MHz. The STS consists of 8 tracking stations based on double-sided silicon micro-strip sensors equipped with fast, self-triggering read-out electronics. With about two million read-out channels, the STS will deliver a high-rate stream of time-stamped data that is transferred to a computing farm for on-line event determination and analysis. The functional building block is a detector module consisting of a sensor, micro-cables and two front-end electronics boards. In this contribution, the development status of the STS components and the system integration is discussed and an outlook on the detector construction is given.
GapFiller: a de novo assembly approach to fill the gap within paired reads
2012-01-01
Background Next Generation Sequencing technologies are able to provide high genome coverages at a relatively low cost. However, due to limited reads' length (from 30 bp up to 200 bp), specific bioinformatics problems have become even more difficult to solve. De novo assembly with short reads, for example, is more complicated at least for two reasons: first, the overall amount of "noisy" data to cope with increased and, second, as the reads' length decreases the number of unsolvable repeats grows. Our work's aim is to go at the root of the problem by providing a pre-processing tool capable to produce (in-silico) longer and highly accurate sequences from a collection of Next Generation Sequencing reads. Results In this paper a seed-and-extend local assembler is presented. The kernel algorithm is a loop that, starting from a read used as seed, keeps extending it using heuristics whose main goal is to produce a collection of error-free and longer sequences. In particular, GapFiller carefully detects reliable overlaps and operates clustering similar reads in order to reconstruct the missing part between the two ends of the same insert. Our tool's output has been validated on 24 experiments using both simulated and real paired reads datasets. The output sequences are declared correct when the seed-mate is found. In the experiments performed, GapFiller was able to extend high percentages of the processed seeds and find their mates, with a false positives rate that turned out to be nearly negligible. Conclusions GapFiller, starting from a sufficiently high short reads coverage, is able to produce high coverages of accurate longer sequences (from 300 bp up to 3500 bp). The procedure to perform safe extensions, together with the mate-found check, turned out to be a powerful criterion to guarantee contigs' correctness. GapFiller has further potential, as it could be applied in a number of different scenarios, including the post-processing validation of insertions/deletions detection pipelines, pre-processing routines on datasets for de novo assembly pipelines, or in any hierarchical approach designed to assemble, analyse or validate pools of sequences. PMID:23095524
Language: Critical Components in Readers with Criminal Referral History
ERIC Educational Resources Information Center
Platt, Derrick E.
2009-01-01
Low levels of reading performance are associated with delinquency. However, few studies have investigated the relationship between early involvement in the justice system and reading problems. This study examined the relationship between youth at various early stages of involvement with criminal behaviors and reading abilities (specifically,…
40 CFR 91.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... deflection should generally not be used. (2) Some high resolution read-out systems, such as computers, data...-second time interval. (b) Operating procedure for analyzers and sampling system. Follow the start-up and... systems may be used provided that additional calibrations are made to ensure the accuracy of the...
Design and Performance of the Multiplexed SQUID/TES Array at Ninety Gigahertz
NASA Astrophysics Data System (ADS)
Stanchfield, Sara; Ade, Peter; Aguirre, James; Brevik, Justus A.; Cho, Hsiao-Mei; Datta, Rahul; Devlin, Mark; Dicker, Simon R.; Dober, Bradley; Duff, Shannon M.; Egan, Dennis; Ford, Pam; Hilton, Gene; Hubmayr, Johannes; Irwin, Kent; Knowles, Kenda; Marganian, Paul; Mason, Brian Scott; Mates, John A. B.; McMahon, Jeff; Mello, Melinda; Mroczkowski, Tony; Romero, Charles; Sievers, Jonathon; Tucker, Carole; Vale, Leila R.; Vissers, Michael; White, Steven; Whitehead, Mark; Ullom, Joel; Young, Alexander
2018-01-01
We present the array performance and astronomical images from early science results from MUSTANG-2, a 90 GHz feedhorn-coupled, microwave SQUID-multiplexed TES bolometer array operating on the Robert C. Byrd Green Bank Telescope (GBT). MUSTANG-2 was installed on the GBT on December 2, 2016 and immediately began commissioning efforts, followed by science observations, which are expected to conclude June 2017. The feedhorn and waveguide-probe-coupled detector technology is a mature technology, which has been used on instrument including the South Pole Telescope, the Atacama Cosmology Telescope, and the Atacama B-mode Search telescope. The microwave SQUID readout system developed for MUSTANG-2 currently reads out 66 detectors with a single coaxial cable and will eventually allow thousands of detectors to be multiplexed. This microwave SQUID multiplexer combines the proven abilities of millimeterwave TES detectors with the multiplexing capabilities of KIDs with no degradation in noise performance of the detectors. Each multiplexing device is read out using warm electronics consisting of a commercially available ROACH board, a DAC/ADC card, and an Intermediate Frequency mixer circuit. The hardware was originally developed by the UC Berkeley Collaboration for Astronomy Signal Processing and Electronic Research (CASPER) group, whose primary goal is to develop scalable FPGA-based hardware with the flexibility to be used in a wide range of radio signal processing applications. MUSTANG-2 is the first on-sky instrument to use microwave SQUID multiplexing and is available as a shared-risk/PI instrument on the GBT. In MUSTANG-2's first season 7 separate proposals were awarded a total of 230 hours of telescope time.
Budavari, Tamas; Langmead, Ben; Wheelan, Sarah J.; Salzberg, Steven L.; Szalay, Alexander S.
2015-01-01
When computing alignments of DNA sequences to a large genome, a key element in achieving high processing throughput is to prioritize locations in the genome where high-scoring mappings might be expected. We formulated this task as a series of list-processing operations that can be efficiently performed on graphics processing unit (GPU) hardware.We followed this approach in implementing a read aligner called Arioc that uses GPU-based parallel sort and reduction techniques to identify high-priority locations where potential alignments may be found. We then carried out a read-by-read comparison of Arioc’s reported alignments with the alignments found by several leading read aligners. With simulated reads, Arioc has comparable or better accuracy than the other read aligners we tested. With human sequencing reads, Arioc demonstrates significantly greater throughput than the other aligners we evaluated across a wide range of sensitivity settings. The Arioc software is available at https://github.com/RWilton/Arioc. It is released under a BSD open-source license. PMID:25780763
DOE Office of Scientific and Technical Information (OSTI.GOV)
HENNIGAN, GARY; SHADID, JOHN; SJAARDEMA, GREGORY
2009-06-08
Nem_spread reads it's input command file (default name nem_spread.inp), takes the named ExodusII geometry definition and spreads out the geometry (and optionally results) contained in that file out to a parallel disk system. The decomposition is taken from a scalar Nemesis load balance file generated by the companion utility nem_slice.
A hybrid short read mapping accelerator
2013-01-01
Background The rapid growth of short read datasets poses a new challenge to the short read mapping problem in terms of sensitivity and execution speed. Existing methods often use a restrictive error model for computing the alignments to improve speed, whereas more flexible error models are generally too slow for large-scale applications. A number of short read mapping software tools have been proposed. However, designs based on hardware are relatively rare. Field programmable gate arrays (FPGAs) have been successfully used in a number of specific application areas, such as the DSP and communications domains due to their outstanding parallel data processing capabilities, making them a competitive platform to solve problems that are “inherently parallel”. Results We present a hybrid system for short read mapping utilizing both FPGA-based hardware and CPU-based software. The computation intensive alignment and the seed generation operations are mapped onto an FPGA. We present a computationally efficient, parallel block-wise alignment structure (Align Core) to approximate the conventional dynamic programming algorithm. The performance is compared to the multi-threaded CPU-based GASSST and BWA software implementations. For single-end alignment, our hybrid system achieves faster processing speed than GASSST (with a similar sensitivity) and BWA (with a higher sensitivity); for pair-end alignment, our design achieves a slightly worse sensitivity than that of BWA but has a higher processing speed. Conclusions This paper shows that our hybrid system can effectively accelerate the mapping of short reads to a reference genome based on the seed-and-extend approach. The performance comparison to the GASSST and BWA software implementations under different conditions shows that our hybrid design achieves a high degree of sensitivity and requires less overall execution time with only modest FPGA resource utilization. Our hybrid system design also shows that the performance bottleneck for the short read mapping problem can be changed from the alignment stage to the seed generation stage, which provides an additional requirement for the future development of short read aligners. PMID:23441908
Long-range interactions and parallel scalability in molecular simulations
NASA Astrophysics Data System (ADS)
Patra, Michael; Hyvönen, Marja T.; Falck, Emma; Sabouri-Ghomi, Mohsen; Vattulainen, Ilpo; Karttunen, Mikko
2007-01-01
Typical biomolecular systems such as cellular membranes, DNA, and protein complexes are highly charged. Thus, efficient and accurate treatment of electrostatic interactions is of great importance in computational modeling of such systems. We have employed the GROMACS simulation package to perform extensive benchmarking of different commonly used electrostatic schemes on a range of computer architectures (Pentium-4, IBM Power 4, and Apple/IBM G5) for single processor and parallel performance up to 8 nodes—we have also tested the scalability on four different networks, namely Infiniband, GigaBit Ethernet, Fast Ethernet, and nearly uniform memory architecture, i.e. communication between CPUs is possible by directly reading from or writing to other CPUs' local memory. It turns out that the particle-mesh Ewald method (PME) performs surprisingly well and offers competitive performance unless parallel runs on PC hardware with older network infrastructure are needed. Lipid bilayers of sizes 128, 512 and 2048 lipid molecules were used as the test systems representing typical cases encountered in biomolecular simulations. Our results enable an accurate prediction of computational speed on most current computing systems, both for serial and parallel runs. These results should be helpful in, for example, choosing the most suitable configuration for a small departmental computer cluster.
[Intervention in dyslexic disorders: phonological awareness training].
Etchepareborda, M C
2003-02-01
Taking into account the systems for the treatment of brain information when drawing up a work plan allows us to recreate processing routines that go from multisensory perception to motor, oral and cognitive production, which is the step prior to executive levels of thought, bottom-up and top-down processing systems. In recent years, the use of phonological methods to prevent or resolve reading disorders has become the fundamental mainstay in the treatment of dyslexia. The work is mainly based on phonological proficiency, which enables the patient to detect phonemes (input), to think about them (performance) and to use them to build words (output). Daily work with rhymes, the capacity to listen, the identification of phrases and words, and handling syllables and phonemes allows us to perform a preventive intervention that enhances the capacity to identify letters, phonological analysis and the reading of single words. We present the different therapeutic models that are most frequently employed. Fast For Word (FFW) training helps make progress in phonematic awareness and other linguistic skills, such as phonological awareness, semantics, syntax, grammar, working memory and event sequencing. With Deco-Fon, a programme for training phonological decoding, work is carried out on the auditory discrimination of pure tones, letters and consonant clusters, auditory processing speed, auditory and phonematic memory, and graphophonological processing, which is fundamental for speech, language and reading writing disorders. Hamlet is a programme based on categorisation activities for working on phonological conceptualisation. It attempts to encourage the analysis of the segments of words, syllables or phonemes, and the classification of a certain segment as belonging or not to a particular phonological or orthographical category. Therapeutic approaches in the early phases of reading are oriented towards two poles based on the basic mechanisms underlying the process of learning to read, the grapheme phoneme transformation process and global word recognition. The interventionalist strategies used at school are focused on the use of cognitive strategy techniques. The purpose of these techniques is to teach pupils practical strategies or resources aimed at overcoming specific deficiencies.
Understanding I/O workload characteristics of a Peta-scale storage system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Youngjae; Gunasekaran, Raghul
2015-01-01
Understanding workload characteristics is critical for optimizing and improving the performance of current systems and software, and architecting new storage systems based on observed workload patterns. In this paper, we characterize the I/O workloads of scientific applications of one of the world s fastest high performance computing (HPC) storage cluster, Spider, at the Oak Ridge Leadership Computing Facility (OLCF). OLCF flagship petascale simulation platform, Titan, and other large HPC clusters, in total over 250 thousands compute cores, depend on Spider for their I/O needs. We characterize the system utilization, the demands of reads and writes, idle time, storage space utilization,more » and the distribution of read requests to write requests for the Peta-scale Storage Systems. From this study, we develop synthesized workloads, and we show that the read and write I/O bandwidth usage as well as the inter-arrival time of requests can be modeled as a Pareto distribution. We also study the I/O load imbalance problems using I/O performance data collected from the Spider storage system.« less
Assessing children's inference generation: what do tests of reading comprehension measure?
Bowyer-Crane, Claudine; Snowling, Margaret J
2005-06-01
Previous research suggests that children with specific comprehension difficulties have problems with the generation of inferences. This raises important questions as to whether poor comprehenders have poor comprehension skills generally, or whether their problems are confined to specific inference types. The main aims of the study were (a) using two commonly used tests of reading comprehension to classify the questions requiring the generation of inferences, and (b) to investigate the relative performance of skilled and less-skilled comprehenders on questions tapping different inference types. The performance of 10 poor comprehenders (mean age 110.06 months) was compared with the performance of 10 normal readers (mean age 112.78 months) on two tests of reading comprehension. A qualitative analysis of the NARA II (form 1) and the WORD comprehension subtest was carried out. Participants were then administered the NARA II, WORD comprehension subtest and a test of non-word reading. The NARA II was heavily reliant on the generation of knowledge-based inferences, while the WORD comprehension subtest was biased towards the retention of literal information. Children identified by the NARA II as having comprehension difficulties performed in the normal range on the WORD comprehension subtests. Further, children with comprehension difficulties performed poorly on questions requiring the generation of knowledge-based and elaborative inferences. However, they were able to answer questions requiring attention to literal information or use of cohesive devices at a level comparable to normal readers. Different reading tests tap different types of inferencing skills. Lessskilled comprehenders have particular difficulty applying real-world knowledge to a text during reading, and this has implications for the formulation of effective intervention strategies.
Type Testing of Model 7200 Automatic TLD Reader.
Malek Mohammadi, M; Hosseini Pooya, S M
2017-04-20
The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
What lies beneath: A comparison of reading aloud in pure alexia and semantic dementia
Hoffman, Paul; Roberts, Daniel J.; Ralph, Matthew A. Lambon; Patterson, Karalyn E.
2014-01-01
Exaggerated effects of word length upon reading-aloud performance define pure alexia, but have also been observed in semantic dementia. Some researchers have proposed a reading-specific account, whereby performance in these two disorders reflects the same cause: impaired orthographic processing. In contrast, according to the primary systems view of acquired reading disorders, pure alexia results from a basic visual processing deficit, whereas degraded semantic knowledge undermines reading performance in semantic dementia. To explore the source of reading deficits in these two disorders, we compared the reading performance of 10 pure alexic and 10 semantic dementia patients, matched in terms of overall severity of reading deficit. The results revealed comparable frequency effects on reading accuracy, but weaker effects of regularity in pure alexia than in semantic dementia. Analysis of error types revealed a higher rate of letter-based errors and a lower rate of regularization responses in pure alexia than in semantic dementia. Error responses were most often words in pure alexia but most often nonwords in semantic dementia. Although all patients made some letter substitution errors, these were characterized by visual similarity in pure alexia and phonological similarity in semantic dementia. Overall, the data indicate that the reading deficits in pure alexia and semantic dementia arise from impairments of visual processing and knowledge of word meaning, respectively. The locus and mechanisms of these impairments are placed within the context of current connectionist models of reading. PMID:24702272
Descriptive and Criterion-Referenced Self-Assessment with L2 Readers
ERIC Educational Resources Information Center
Brantmeier, Cindy; Vanderplank, Robert
2008-01-01
Brantmeier [Brantmeier, C., 2006. "Advanced L2 learners and reading placement: self-assessment, computer-based testing, and subsequent performance." 'System 34" (1), 15-35] found that self-assessment (SA) of second language (L2) reading ability is not an accurate predictor for computer-based testing or subsequent classroom performance. With 359…
Announcements | High-Performance Computing | NREL
12th from 12 - 3 PM. Continue reading Data Transfer Queue March 08, 2018 A new queue "data , scratch) and MSS. Continue reading Purge-Alert January 11, 2018 We now have a notification method that . Continue reading Please Move Inactive Files Off the /projects File System January 11, 2018 The /projects
Reading through the Life Span: Individual Differences in Psycholinguistic Effects
ERIC Educational Resources Information Center
Davies, Rob A. I.; Arnell, Ruth; Birchenough, Julia M. H.; Grimmond, Debbie; Houlson, Sam
2017-01-01
The effects of psycholinguistic variables are critical to the evaluation of theories about the cognitive reading system. However, reading research has tended to focus on the impact of key variables on average performance. We report the first investigation examining variation in psycholinguistic effects across the life span, from childhood into old…
ERIC Educational Resources Information Center
Lloyd, Sonya LaShawn
2014-01-01
Providing academic assistance to English Language Learners (ELLs) is varied and often ineffective. The purpose of this causal-comparative study was to determine if there was a relationship between 9th grade students' performance on the High School Graduation Exam (HSGE) in reading and language and the Push-in and Pull-out models of instruction.…
Left neglect dyslexia and the effect of stimulus duration.
Arduino, Lisa S; Vallar, Giuseppe; Burani, Cristina
2006-01-01
The present study investigated the effects of the duration of the stimulus on the reading performance of right-brain-damaged patients with left neglect dyslexia. Three Italian patients read aloud words and nonwords, under conditions of unlimited time of stimulus exposure and of timed presentation. In the untimed condition, the majority of the patients' errors involved the left side of the letter string (i.e., neglect dyslexia errors). Conversely, in the timed condition, although the overall level of performance decreased, errors were more evenly distributed across the whole letter string (i.e., visual - nonlateralized - errors). This reduction of neglect errors with a reduced time of presentation of the stimulus may reflect the read out of elements of the letter string from a preserved visual storage component, such as iconic memory. Conversely, a time-unlimited presentation of the stimulus may bring about the rightward bias that characterizes the performance of neglect patients, possibly by a capture of the patients' attention by the final (rightward) letters of the string.
SDS: A Framework for Scientific Data Services
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Bin; Byna, Surendra; Wu, Kesheng
2013-10-31
Large-scale scientific applications typically write their data to parallel file systems with organizations designed to achieve fast write speeds. Analysis tasks frequently read the data in a pattern that is different from the write pattern, and therefore experience poor I/O performance. In this paper, we introduce a prototype framework for bridging the performance gap between write and read stages of data access from parallel file systems. We call this framework Scientific Data Services, or SDS for short. This initial implementation of SDS focuses on reorganizing previously written files into data layouts that benefit read patterns, and transparently directs read callsmore » to the reorganized data. SDS follows a client-server architecture. The SDS Server manages partial or full replicas of reorganized datasets and serves SDS Clients' requests for data. The current version of the SDS client library supports HDF5 programming interface for reading data. The client library intercepts HDF5 calls and transparently redirects them to the reorganized data. The SDS client library also provides a querying interface for reading part of the data based on user-specified selective criteria. We describe the design and implementation of the SDS client-server architecture, and evaluate the response time of the SDS Server and the performance benefits of SDS.« less
Improvement of Nonlinearity Correction for BESIII ETOF Upgrade
NASA Astrophysics Data System (ADS)
Sun, Weijia; Cao, Ping; Ji, Xiaolu; Fan, Huanhuan; Dai, Hongliang; Zhang, Jie; Liu, Shubin; An, Qi
2015-08-01
An improved scheme to implement integral non-linearity (INL) correction of time measurements in the Beijing Spectrometer III Endcap Time-of-Flight (BESIII ETOF) upgrade system is presented in this paper. During upgrade, multi-gap resistive plate chambers (MRPC) are introduced as ETOF detectors which increases the total number of time measurement channels to 1728. The INL correction method adopted in BESIII TOF proved to be of limited use, because the sharply increased number of electronic channels required for reading out the detector strips degrade the system configuration efficiency severely. Furthermore, once installed into the spectrometer, BESIII TOF electronics do not support the TDCs' nonlinearity evaluation online. In this proposed method, INL data used for the correction algorithm are automatically imported from a non-volatile read-only memory (ROM) instead of from data acquisition software. This guarantees the real-time performance and system efficiency of the INL correction, especially for the ETOF upgrades with massive number of channels. Besides, a signal that is not synchronized to the system 41.65 MHz clock from BEPCII is sent to the frontend electronics (FEE) to simulate pseudo-random test pulses for the purpose of online nonlinearity evaluation. Test results show that the time measuring INL errors in one module with 72 channels can be corrected online and in real time.
The art and science of missile defense sensor design
NASA Astrophysics Data System (ADS)
McComas, Brian K.
2014-06-01
A Missile Defense Sensor is a complex optical system, which sits idle for long periods of time, must work with little or no on-board calibration, be used to find and discriminate targets, and guide the kinetic warhead to the target within minutes of launch. A short overview of the Missile Defense problem will be discussed here, as well as, the top-level performance drivers, like Noise Equivalent Irradiance (NEI), Acquisition Range, and Dynamic Range. These top-level parameters influence the choice of optical system, mechanical system, focal plane array (FPA), Read Out Integrated Circuit (ROIC), and cryogenic system. This paper will not only discuss the physics behind the performance of the sensor, but it will also discuss the "art" of optimizing the performance of the sensor given the top level performance parameters. Balancing the sensor sub-systems is key to the sensor's performance in these highly stressful missions. Top-level performance requirements impact the choice of lower level hardware and requirements. The flow down of requirements to the lower level hardware will be discussed. This flow down directly impacts the FPA, where careful selection of the detector is required. The flow down also influences the ROIC and cooling requirements. The key physics behind the detector and cryogenic system interactions will be discussed, along with the balancing of subsystem performance. Finally, the overall system balance and optimization will be discussed in the context of missile defense sensors and expected performance of the overall kinetic warhead.
High operation temperature of HgCdTe photodiodes by bulk defect passivation
NASA Astrophysics Data System (ADS)
Boieriu, Paul; Velicu, S.; Bommena, R.; Buurma, C.; Blisset, C.; Grein, C.; Sivananthan, S.; Hagler, P.
2013-01-01
Spatial noise and the loss of photogenerated current due material non-uniformities limit the performance of long wavelength infrared (LWIR) HgCdTe detector arrays. Reducing the electrical activity of defects is equivalent to lowering their density, thereby allowing detection and discrimination over longer ranges. Infrared focal plane arrays (IRFPAs) in other spectral bands will also benefit from detectivity and uniformity improvements. Larger signal-to-noise ratios permit either improved accuracy of detection/discrimination when an IRFPA is employed under current operating conditions, or provide similar performance with the IRFPA operating under less stringent conditions such as higher system temperature, increased system jitter or damaged read out integrated circuit (ROIC) wells. The bulk passivation of semiconductors with hydrogen continues to be investigated for its potential to become a tool for the fabrication of high performance devices. Inductively coupled plasmas have been shown to improve the quality and uniformity of semiconductor materials and devices. The retention of the benefits following various aging conditions is discussed here.
ERIC Educational Resources Information Center
Spichtig, Alexandra N.; Hiebert, Elfrieda H.; Vorstius, Christian; Pascoe, Jeffrey P.; Pearson, P. David; Radach, Ralph
2016-01-01
The present study measured the comprehension-based silent reading efficiency of U.S. students in grades 2, 4, 6, 8, 10, and 12. Students read standardized grade-level passages while an eye movement recording system was used to measure reading rate, fixations (eye stops) per word, fixation durations, and regressions (right-to-left eye movements)…
ERIC Educational Resources Information Center
Reed, Deborah K.; Swanson, Elizabeth; Petscher, Yaacov; Vaughn, Sharon
2014-01-01
Teacher read-alouds (TRA) are common in middle and high school content area classes. Because the practice of reading the textbook out loud to students is often used out of concern about students' ability to understand and learn from text when reading silently (SR), this randomized controlled trial was designed to experimentally manipulate text…
Miranda, Ana; Colomer, Carla; Mercader, Jessica; Fernández, M Inmaculada; Presentación, M Jesús
2015-01-01
The early assessment of the executive processes using ecologically valid instruments is essential for identifying deficits and planning actions to deal with possible adverse consequences. The present study has two different objectives. The first objective is to analyze the relationship between preschoolers' performance on tests of Working Memory and Inhibition and parents' and teachers' ratings of these executive functions (EFs) using the Behavior Rating Inventory of Executive Function (BRIEF). The second objective consists of studying the predictive value of the different EF measures (performance-based test and rating scales) on Inattention and Hyperactivity/Impulsivity behaviors and on indicators of word reading performance. The participants in the study were 209 children in the last year of preschool, their teachers and their families. Performance-based tests of Working Memory and Inhibition were administered, as well as word reading measures (accuracy and speed). The parents and teachers filled out rating scales of the EF and typical behaviors of attention deficit hyperactivity disorder (ADHD) symptomatology. Moderate correlation values were found between the different EF assessments procedures, although the results varied depending on the different domains. Metacognition Index from the BRIEF presented stronger correlations with verbal working memory tests than with inhibition tests. Both the rating scales and the performance-based tests were significant predictors of Inattention and Hyperactivity/Impulsivity behaviors and the reading achievement measures. However, the BRIEF explained a greater percentage of variance in the case of the ADHD symptomatology, while the performance-based tests explained reading achievement to a greater degree. The implications of the findings for research and clinical practice are discussed.
Miranda, Ana; Colomer, Carla; Mercader, Jessica; Fernández, M. Inmaculada; Presentación, M. Jesús
2015-01-01
The early assessment of the executive processes using ecologically valid instruments is essential for identifying deficits and planning actions to deal with possible adverse consequences. The present study has two different objectives. The first objective is to analyze the relationship between preschoolers’ performance on tests of Working Memory and Inhibition and parents’ and teachers’ ratings of these executive functions (EFs) using the Behavior Rating Inventory of Executive Function (BRIEF). The second objective consists of studying the predictive value of the different EF measures (performance-based test and rating scales) on Inattention and Hyperactivity/Impulsivity behaviors and on indicators of word reading performance. The participants in the study were 209 children in the last year of preschool, their teachers and their families. Performance-based tests of Working Memory and Inhibition were administered, as well as word reading measures (accuracy and speed). The parents and teachers filled out rating scales of the EF and typical behaviors of attention deficit hyperactivity disorder (ADHD) symptomatology. Moderate correlation values were found between the different EF assessments procedures, although the results varied depending on the different domains. Metacognition Index from the BRIEF presented stronger correlations with verbal working memory tests than with inhibition tests. Both the rating scales and the performance-based tests were significant predictors of Inattention and Hyperactivity/Impulsivity behaviors and the reading achievement measures. However, the BRIEF explained a greater percentage of variance in the case of the ADHD symptomatology, while the performance-based tests explained reading achievement to a greater degree. The implications of the findings for research and clinical practice are discussed. PMID:25972833
A multiplexed TOF and DOI capable PET detector using a binary position sensitive network.
Bieniosek, M F; Cates, J W; Levin, C S
2016-11-07
Time of flight (TOF) and depth of interaction (DOI) capabilities can significantly enhance the quality and uniformity of positron emission tomography (PET) images. Many proposed TOF/DOI PET detectors require complex readout systems using additional photosensors, active cooling, or waveform sampling. This work describes a high performance, low complexity, room temperature TOF/DOI PET module. The module uses multiplexed timing channels to significantly reduce the electronic readout complexity of the PET detector while maintaining excellent timing, energy, and position resolution. DOI was determined using a two layer light sharing scintillation crystal array with a novel binary position sensitive network. A 20 mm effective thickness LYSO crystal array with four 3 mm × 3 mm silicon photomultipliers (SiPM) read out by a single timing channel, one energy channel and two position channels achieved a full width half maximum (FWHM) coincidence time resolution of 180 ± 2 ps with 10 mm of DOI resolution and 11% energy resolution. With sixteen 3 mm × 3 mm SiPMs read out by a single timing channel, one energy channel and four position channels a coincidence time resolution 204 ± 1 ps was achieved with 10 mm of DOI resolution and 15% energy resolution. The methods presented here could significantly simplify the construction of high performance TOF/DOI PET detectors.
Analysis of read-out heating rate effects on the glow peaks of TLD-100 using WinGCF software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauk, Sabar, E-mail: sabar@usm.my; Hussin, Siti Fatimah; Alam, Md. Shah
This study was done to analyze the effects of the read-out heating rate on the LiF:Mg,Ti (TLD-100) thermoluminescent dosimeters (TLD) glow peaks using WinGCF computer software. The TLDs were exposed to X-ray photons with a potential difference of 72 kVp and 200 mAs in air and were read-out using a Harshaw 3500 TLD reader. The TLDs were read-out using four read-out heating rates at 10, 7, 4 and 1 °C s{sup −1}. It was observed that lowering the heating rate could separate more glow peaks. The activation energy for peak 5 was found to be lower than that for peakmore » 4. The peak maximum temperature and the integral value of the main peak decreased as the heating rate decreases.« less
ERIC Educational Resources Information Center
Ulum, Ömer Gökhan
2016-01-01
Bloom's taxonomy is probably the most commonly used one among the cognitive process models. It is a classification system that emphasizes the procedures starting from remembering the knowledge to more complex cognitive levels like evaluating the knowledge. Firstly, the aim of this study has been to find out to what extent Bloom's taxonomy is…
NASA Technical Reports Server (NTRS)
Caplin, R. S.; Royer, E. R.
1978-01-01
Attempts are made to provide a total design of a Microbial Load Monitor (MLM) system flight engineering model. Activities include assembly and testing of Sample Receiving and Card Loading Devices (SRCLDs), operator related software, and testing of biological samples in the MLM. Progress was made in assembling SRCLDs with minimal leaks and which operate reliably in the Sample Loading System. Seven operator commands are used to control various aspects of the MLM such as calibrating and reading the incubating reading head, setting the clock and reading time, and status of Card. Testing of the instrument, both in hardware and biologically, was performed. Hardware testing concentrated on SRCLDs. Biological testing covered 66 clinical and seeded samples. Tentative thresholds were set and media performance listed.
Radio Frequency Identification (RFID) Based Employee Attendance Management System
NASA Astrophysics Data System (ADS)
Maramis, G. D. P.; Rompas, P. T. D.
2018-02-01
Manually recorded attendance of all the employees has produced some problems such as the data accuracy and staff performance efficiency. The objective of this research is to design and develop a software of RFID attendance system which is integrated with database system. This RFID attendance system was developed using several main components such as tags that will be used as a replacement of ID cards and a reader device that will read the information related to the employee attendance. The result of this project is a software of RFID attendance system that is integrated with the database and has a function to store the data or information of every single employee. This system has a maximum reading range of 2 cm with success probability of 1 and requires a minimum interval between readings of 2 seconds in order to achieve an optimal functionality. By using the system, the discipline attitude of the employees and also the performance of the staff will be improved instantly.
Out-of-Core Streamline Visualization on Large Unstructured Meshes
NASA Technical Reports Server (NTRS)
Ueng, Shyh-Kuang; Sikorski, K.; Ma, Kwan-Liu
1997-01-01
It's advantageous for computational scientists to have the capability to perform interactive visualization on their desktop workstations. For data on large unstructured meshes, this capability is not generally available. In particular, particle tracing on unstructured grids can result in a high percentage of non-contiguous memory accesses and therefore may perform very poorly with virtual memory paging schemes. The alternative of visualizing a lower resolution of the data degrades the original high-resolution calculations. This paper presents an out-of-core approach for interactive streamline construction on large unstructured tetrahedral meshes containing millions of elements. The out-of-core algorithm uses an octree to partition and restructure the raw data into subsets stored into disk files for fast data retrieval. A memory management policy tailored to the streamline calculations is used such that during the streamline construction only a very small amount of data are brought into the main memory on demand. By carefully scheduling computation and data fetching, the overhead of reading data from the disk is significantly reduced and good memory performance results. This out-of-core algorithm makes possible interactive streamline visualization of large unstructured-grid data sets on a single mid-range workstation with relatively low main-memory capacity: 5-20 megabytes. Our test results also show that this approach is much more efficient than relying on virtual memory and operating system's paging algorithms.
Bowman, Margo; Treiman, Rebecca
2002-08-01
From an early age, children can go beyond rote memorization to form links between print and speech that are based on letter names in the initial positions of words (Treiman & Rodriguez, 1999; Treiman, Sotak, & Bowman, 2001). For example, children's knowledge of the name of the letter t helps them learn that the novel word TM is pronounced as team. Four experiments were carried out to determine whether letter names at the ends of words are equally useful. Four- and five-year-olds derived little benefit from such information in reading (Experiments 1 and 3) or spelling (Experiment 2), although adults did (Experiment 4). For young children, word-final information appears to have less influence on reading and spelling performance than does word-initial information. The results help delineate the circumstances under which children can go beyond a logographic approach in learning about print.
ERIC Educational Resources Information Center
Rahman, Taslima; Mislevy, Robert J.
2017-01-01
To demonstrate how methodologies for assessing reading comprehension can grow out of views of the construct suggested in the reading research literature, we constructed tasks and carried out psychometric analyses that were framed in accordance with 2 leading reading models. In estimating item difficulty and subsequently, examinee proficiency, an…
Burns, Randal; Roncal, William Gray; Kleissas, Dean; Lillaney, Kunal; Manavalan, Priya; Perlman, Eric; Berger, Daniel R.; Bock, Davi D.; Chung, Kwanghun; Grosenick, Logan; Kasthuri, Narayanan; Weiler, Nicholas C.; Deisseroth, Karl; Kazhdan, Michael; Lichtman, Jeff; Reid, R. Clay; Smith, Stephen J.; Szalay, Alexander S.; Vogelstein, Joshua T.; Vogelstein, R. Jacob
2013-01-01
We describe a scalable database cluster for the spatial analysis and annotation of high-throughput brain imaging data, initially for 3-d electron microscopy image stacks, but for time-series and multi-channel data as well. The system was designed primarily for workloads that build connectomes— neural connectivity maps of the brain—using the parallel execution of computer vision algorithms on high-performance compute clusters. These services and open-science data sets are publicly available at openconnecto.me. The system design inherits much from NoSQL scale-out and data-intensive computing architectures. We distribute data to cluster nodes by partitioning a spatial index. We direct I/O to different systems—reads to parallel disk arrays and writes to solid-state storage—to avoid I/O interference and maximize throughput. All programming interfaces are RESTful Web services, which are simple and stateless, improving scalability and usability. We include a performance evaluation of the production system, highlighting the effec-tiveness of spatial data organization. PMID:24401992
Clarissa Spoken Dialogue System for Procedure Reading and Navigation
NASA Technical Reports Server (NTRS)
Hieronymus, James; Dowding, John
2004-01-01
Speech is the most natural modality for humans use to communicate with other people, agents and complex systems. A spoken dialogue system must be robust to noise and able to mimic human conversational behavior, like correcting misunderstandings, answering simple questions about the task and understanding most well formed inquiries or commands. The system aims to understand the meaning of the human utterance, and if it does not, then it discards the utterance as being meant for someone else. The first operational system is Clarissa, a conversational procedure reader and navigator, which will be used in a System Development Test Objective (SDTO) on the International Space Station (ISS) during Expedition 10. In the present environment one astronaut reads the procedure on a Manual Procedure Viewer (MPV) or paper, and has to stop to read or turn pages, shifting focus from the task. Clarissa is designed to read and navigate ISS procedures entirely with speech, while the astronaut has his eyes and hands engaged in performing the task. The system also provides an MPV like graphical interface so the procedure can be read visually. A demo of the system will be given.
Capacity for self-monitoring reading comprehension in Elementary School.
Bueno, Gabriela Juliane; Carvalho, Carolina Alves Ferreira; Ávila, Clara Regina Brandão de
2017-06-08
To investigate the capacity for self-monitoring reading comprehension in Brazilian Elementary School students. Fifty-three Elementary students in the 5th and 9th grades from two Public Schools in the city of São Paulo were assessed. They were selected based on their oral reading rate and grouped according to their performance in reading comprehension in the following categories: Group with best comprehension: students with adequate rate and accuracy, without difficulties in reading comprehension; Group with worst comprehension: students with adequate rate and accuracy but with difficulties in reading comprehension. Two narrative texts followed by eight questions to assess reading comprehension were presented. Two sentences and two words were replaced by ungrammatical elements and pseudo-words. Under the condition of spontaneous monitoring, students read the text aloud and answered the questions. The analysis considered the calculation of hesitation, self-correction, repetitions and mistakes. Under the condition of directed monitoring, students were instructed to read the text, either aloud or silently, after being told that certain parts of the text could not make sense, and they were oriented to underline such parts. The analysis was carried out by counting of underlined items. The comparisons were made with the Mann-Whitney test. A difference was observed between the groups only at the sentence level among the 9th grade schoolchildren under the spontaneous monitoring and among the 5th grade schoolchildren under directed monitoring. Students with worst comprehension had a poorer performance to monitor the presence of ungrammatical sentences than their peers with best comprehension.
ERIC Educational Resources Information Center
Hsu, Ching-Kun; Hwang, Gwo-Jen; Chang, Chih-Kai
2013-01-01
In this paper, a personalized recommendation-based mobile language learning approach is proposed. A mobile learning system has been developed based on the approach by providing a reading material recommendation mechanism for guiding EFL (English as Foreign Language) students to read articles that match their preferences and knowledge levels, and a…
Nguyen, Nhung X; Besch, Dorothea; Bartz-Schmidt, Karl; Gelisken, Faik; Trauzettel-Klosinski, Susanne
2007-12-01
The aim of the present study was to evaluate the power of magnification required, reading performance with low-vision aids and vision-related quality of life with reference to reading ability and ability to carry out day-to-day activities in patients after macular translocation. This study included 15 patients who had undergone macular translocation with 360-degree peripheral retinectomy. The mean length of follow-up was 19.2 +/- 10.8 months (median 11 months). At the final examination, the impact of visual impairment on reading ability and quality of life was assessed according to a modified 9-item questionnaire in conjunction with a comprehensive clinical examination, which included assessment of best corrected visual acuity (BCVA), the magnification power required for reading, use of low-vision aids and reading speed. Patients rated the extent to which low vision restricted their ability to read and participate in other activities that affect quality of life. Responses were scored on a scale of 1.0 (optimum self-evaluation) to 5.0 (very poor). In the operated eye, overall mean postoperative BCVA (distance) was not significantly better than mean preoperative BCVA (0.11 +/- 0.06 and 0.15 +/- 0.08, respectively; p = 0.53). However, 53% of patients reported a subjective increase in visual function after treatment. At the final visit, the mean magnification required was x 7.7 +/- 6.7. A total of 60% of patients needed optical magnifiers for reading and in 40% of patients closed-circuit TV systems were necessary. All patients were able to read newspaper print using adapted low-vision aids at a mean reading speed of 71 +/- 40 words per minute. Mean self-reported scores were 3.2 +/- 1.1 for reading, 2.5 +/- 0.7 for day-to-day activities and 2.7 +/- 3.0 for outdoor walking and using steps or stairs. Patients' levels of dependency were significantly correlated with scores for reading (p = 0.01), day-to-day activities (p < 0.001) and outdoor walking and using steps (p = 0.001). The evaluation of self-reported visual function and vision-related quality of life in patients after macular translocation is necessary to obtain detailed information on treatment effects. Our results indicated improvement in patients' subjective evaluations of visual function, without significant improvement in visual acuity. The postoperative clinical benefits of treatment coincide with subjective benefits in terms of reading ability, quality of life and patient satisfaction. Our study confirms the importance and efficiency of visual rehabilitation with aids for low vision after surgery.
NASA Astrophysics Data System (ADS)
Mosset, J.-B.; Stoykov, A.; Greuter, U.; Gromov, A.; Hildebrandt, M.; Panzner, T.; Schlumpf, N.
2017-02-01
A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on a ZnS:6LiF scintillator with embedded WLS fibers which are read out with SiPMs. In this paper, we present the 16-ch module, the dedicated readout electronics, a direct comparison between the performance of the diffractometer obtained with the current 3He detector and with the 16-ch detection module, and the channel-to-channel uniformity.
A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope
NASA Technical Reports Server (NTRS)
Benford, Dominic; Staguhn, Johannes G.; Chervenak, James A.; Chen, Tina C.; Moseley, S. Harvey; Wollack, Edward J.; Devlin, Mark J.; Dicker, Simon R.; Supanich, Mark
2004-01-01
In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.
40 CFR 91.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to § 91.325 and § 91.409. (c) Emission measurement accuracy—bag sampling. (1) Good engineering... deflection should generally not be used. (2) Some high resolution read-out systems, such as computers, data...
40 CFR 91.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to § 91.325 and § 91.409. (c) Emission measurement accuracy—bag sampling. (1) Good engineering... deflection should generally not be used. (2) Some high resolution read-out systems, such as computers, data...
40 CFR 91.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to § 91.325 and § 91.409. (c) Emission measurement accuracy—bag sampling. (1) Good engineering... deflection should generally not be used. (2) Some high resolution read-out systems, such as computers, data...
ERIC Educational Resources Information Center
Barnes, Martha J.
2010-01-01
This study was undertaken to investigate the effects of self-efficacy on the performance of General Educational Development (GED) and high school graduates enrolled in developmental reading skills courses. The sample for the study consisted of 100 high school and 31 GED graduates enrolled in developmental reading courses in a midwestern community…
Design and evaluation of a hybrid storage system in HEP environment
NASA Astrophysics Data System (ADS)
Xu, Qi; Cheng, Yaodong; Chen, Gang
2017-10-01
Nowadays, the High Energy Physics experiments produce a large amount of data. These data are stored in mass storage systems which need to balance the cost, performance and manageability. In this paper, a hybrid storage system including SSDs (Solid-state Drive) and HDDs (Hard Disk Drive) is designed to accelerate data analysis and maintain a low cost. The performance of accessing files is a decisive factor for the HEP computing system. A new deployment model of Hybrid Storage System in High Energy Physics is proposed which is proved to have higher I/O performance. The detailed evaluation methods and the evaluations about SSD/HDD ratio, and the size of the logic block are also given. In all evaluations, sequential-read, sequential-write, random-read and random-write are all tested to get the comprehensive results. The results show the Hybrid Storage System has good performance in some fields such as accessing big files in HEP.
Development of X-ray CCD camera based X-ray micro-CT system
NASA Astrophysics Data System (ADS)
Sarkar, Partha S.; Ray, N. K.; Pal, Manoj K.; Baribaddala, Ravi; Agrawal, Ashish; Kashyap, Y.; Sinha, A.; Gadkari, S. C.
2017-02-01
Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.
ERIC Educational Resources Information Center
Tuncer, Murat; Bahadir, Ferdi
2014-01-01
In this study, the effect of screen reading and reading from printed out material on student success and permanency in Introduction to Computer Lesson is investigated. Study group of the research consists of 78 freshman students registered in Erzincan University Refahiye Vocational School Post Service department. Study groups of research consist…
The design of high performance, low power triple-track magnetic sensor chip.
Wu, Xiulong; Li, Minghua; Lin, Zhiting; Xi, Mengyuan; Chen, Junning
2013-07-09
This paper presents a design of a high performance and low power consumption triple-track magnetic sensor chip which was fabricated in TSMC 0.35 μm CMOS process. This chip is able to simultaneously sense, decode and read out the information stored in triple-track magnetic cards. A reference voltage generating circuit, a low-cost filter circuit, a power-on reset circuit, an RC oscillator, and a pre-decoding circuit are utilized as the basic modules. The triple-track magnetic sensor chip has four states, i.e., reset, sleep, swiping card and data read-out. In sleep state, the internal RC oscillator is closed, which means that the digital part does not operate to optimize energy consumption. In order to improve decoding accuracy and expand the sensing range of the signal, two kinds of circuit are put forward, naming offset correction circuit, and tracking circuit. With these two circuits, the sensing function of this chip can be more efficiently and accurately. We simulated these circuit modules with TSMC technology library. The results showed that these modules worked well within wide range input signal. Based on these results, the layout and tape-out were carried out. The measurement results showed that the chip do function well within a wide swipe speed range, which achieved the design target.
The Design of High Performance, Low Power Triple-Track Magnetic Sensor Chip
Wu, Xiulong; Li, Minghua; Lin, Zhiting; Xi, Mengyuan; Chen, Junning
2013-01-01
This paper presents a design of a high performance and low power consumption triple-track magnetic sensor chip which was fabricated in TSMC 0.35 μm CMOS process. This chip is able to simultaneously sense, decode and read out the information stored in triple-track magnetic cards. A reference voltage generating circuit, a low-cost filter circuit, a power-on reset circuit, an RC oscillator, and a pre-decoding circuit are utilized as the basic modules. The triple-track magnetic sensor chip has four states, i.e., reset, sleep, swiping card and data read-out. In sleep state, the internal RC oscillator is closed, which means that the digital part does not operate to optimize energy consumption. In order to improve decoding accuracy and expand the sensing range of the signal, two kinds of circuit are put forward, naming offset correction circuit, and tracking circuit. With these two circuits, the sensing function of this chip can be more efficiently and accurately. We simulated these circuit modules with TSMC technology library. The results showed that these modules worked well within wide range input signal. Based on these results, the layout and tape-out were carried out. The measurement results showed that the chip do function well within a wide swipe speed range, which achieved the design target. PMID:23839231
Taylor, John J; Bambrick, Rachel; Brand, Andrew; Bray, Nathan; Dutton, Michelle; Harper, Robert A; Hoare, Zoe; Ryan, Barbara; Edwards, Rhiannon T; Waterman, Heather; Dickinson, Christine
2017-07-01
To compare the performance of near vision activities using additional portable electronic vision enhancement systems (p-EVES), to using optical magnifiers alone, by individuals with visual impairment. A total of 100 experienced optical aid users were recruited from low vision clinics at Manchester Royal Eye Hospital, Manchester, UK, to a prospective two-arm cross-over randomised controlled trial. Reading, performance of near vision activities, and device usage were evaluated at baseline; and at the end of each study arm (Intervention A: existing optical aids plus p-EVES; Intervention B: optical aids only) which was after 2 and 4 months. A total of 82 participants completed the study. Overall, maximum reading speed for high contrast sentences was not statistically significantly different for optical aids and p-EVES, although the critical print size and threshold print size which could be accessed with p-EVES were statistically significantly smaller (p < 0.001 in both cases). The optical aids were used for a larger number of tasks (p < 0.001), and used more frequently (p < 0.001). However p-EVES were preferred for leisure reading by 70% of participants, and allowed longer duration of reading (p < 0.001). During the study arm when they had a p-EVES device, participants were able to carry out more tasks independently (p < 0.001), and reported less difficulty with a range of near vision activities (p < 0.001). The study provides evidence that p-EVES devices can play a useful role in supplementing the range of low vision aids used to reduce activity limitation for near vision tasks. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.
Fundamentals of SCADA and automated meter reading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwok, A.
1992-02-01
This paper discusses SCADA systems allow users to control and acquire data from remote facilities such as compressors, pressure-regulating stations, control valves and measurement stations. In general, a SCADA system performs functions in sequential control, continuous control, supervisory setpoint control and data acquisitions. AMR systems allow users to obtain up-to-date information on their gas demand. When AMR was in its infancy, equipment was designed only to read and record gas consumption values. The basic function of an early AMR system was to read gas volume at a fixed interval and record the data in its memory until it communicated withmore » a central receiving facility.« less
The Impact of Literacy Intervention on Academic Performance of Third Grade At-Risk Students
ERIC Educational Resources Information Center
Williams, Vernita
2015-01-01
Third grade at-risk students in Wilson County Schools, Wilson, NC continuously perform below the state average on the North Carolina Third Grade Reading End-of-Grade test. Leaders in the Wilson County Schools school district implemented a literacy pull-out intervention program for third grade at-risk students as a strategy to improve reading…
NASA Astrophysics Data System (ADS)
Jiang, Jun; Bai, Zi Long; Chen, Zhi Hui; He, Long; Zhang, David Wei; Zhang, Qing Hua; Shi, Jin An; Park, Min Hyuk; Scott, James F.; Hwang, Cheol Seong; Jiang, An Quan
2018-01-01
Erasable conductive domain walls in insulating ferroelectric thin films can be used for non-destructive electrical read-out of the polarization states in ferroelectric memories. Still, the domain-wall currents extracted by these devices have not yet reached the intensity and stability required to drive read-out circuits operating at high speeds. This study demonstrated non-destructive read-out of digital data stored using specific domain-wall configurations in epitaxial BiFeO3 thin films formed in mesa-geometry structures. Partially switched domains, which enable the formation of conductive walls during the read operation, spontaneously retract when the read voltage is removed, reducing the accumulation of mobile defects at the domain walls and potentially improving the device stability. Three-terminal memory devices produced 14 nA read currents at an operating voltage of 5 V, and operated up to T = 85 °C. The gap length can also be smaller than the film thickness, allowing the realization of ferroelectric memories with device dimensions far below 100 nm.
Active Flash: Out-of-core Data Analytics on Flash Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boboila, Simona; Kim, Youngjae; Vazhkudai, Sudharshan S
2012-01-01
Next generation science will increasingly come to rely on the ability to perform efficient, on-the-fly analytics of data generated by high-performance computing (HPC) simulations, modeling complex physical phenomena. Scientific computing workflows are stymied by the traditional chaining of simulation and data analysis, creating multiple rounds of redundant reads and writes to the storage system, which grows in cost with the ever-increasing gap between compute and storage speeds in HPC clusters. Recent HPC acquisitions have introduced compute node-local flash storage as a means to alleviate this I/O bottleneck. We propose a novel approach, Active Flash, to expedite data analysis pipelines bymore » migrating to the location of the data, the flash device itself. We argue that Active Flash has the potential to enable true out-of-core data analytics by freeing up both the compute core and the associated main memory. By performing analysis locally, dependence on limited bandwidth to a central storage system is reduced, while allowing this analysis to proceed in parallel with the main application. In addition, offloading work from the host to the more power-efficient controller reduces peak system power usage, which is already in the megawatt range and poses a major barrier to HPC system scalability. We propose an architecture for Active Flash, explore energy and performance trade-offs in moving computation from host to storage, demonstrate the ability of appropriate embedded controllers to perform data analysis and reduction tasks at speeds sufficient for this application, and present a simulation study of Active Flash scheduling policies. These results show the viability of the Active Flash model, and its capability to potentially have a transformative impact on scientific data analysis.« less
NASA Astrophysics Data System (ADS)
Stewart, John
2015-04-01
The amount of time spent on out-of-class activities such as working homework, reading, and studying for examinations is presented for 10 years of an introductory, calculus-based physics class at a large public university. While the class underwent significant change in the 10 years studied, the amount of time invested by students in weeks not containing an in-semester examination was constant and did not vary with the length of the reading or homework assignments. The amount of time spent preparing for examinations did change as the course was modified. The time spent on class assignments, both reading and homework, did not scale linearly with the length of the assignment. The time invested in both reading and homework per length of the assignment decreased as the assignments became longer. The class average time invested in examination preparation did change with the average performance on previous examinations in the same class, with more time spent in preparation for lower previous examination scores (R2 = 0 . 70).
NASA Astrophysics Data System (ADS)
Laguna, M. F.; Holgado, M.; Santamaría, B.; López, A.; Maigler, M.; Lavín, A.; de Vicente, J.; Soria, J.; Suarez, T.; Bardina, C.; Jara, M.; Sanza, F. J.; Casquel, R.; Otón, A.; Riesgo, T.
2015-03-01
Biophotonic Sensing Cells (BICELLs) are demonstrated to be an efficient technology for label-free biosensing and in concrete for evaluating dry eye diseases. The main advantage of BICELLs is its capability to be used by dropping directly a tear into the sensing surface without the need of complex microfluidics systems. Among this advantage, compact Point of Care read-out device is employed with the capability of evaluating different types of BICELLs packaged on Biochip-Kits that can be fabricated by using different sensing surfaces material. In this paper, we evaluate the performance of the combination of three sensing surface materials: (3-Glycidyloxypropyl) trimethoxysilane (GPTMS), SU-8 resist and Nitrocellulose (NC) for two different biomarkers relevant for dry eye diseases: PRDX-5 and ANXA-11.
NASA Astrophysics Data System (ADS)
Schroeder, Edward; Mauskopf, Philip; Pilyavsky, Genady; Sinclair, Adrian; Smith, Nathan; Bryan, Sean; Mani, Hamdi; Morozov, Dmitry; Berggren, Karl; Zhu, Di; Smirnov, Konstantin; Vakhtomin, Yuriy
2016-08-01
We describe the performance of detector modules containing silicon single photon avalanche photodiodes (SPADs) and superconducting nanowire single photon detectors (SNSPDs) to be used for intensity interferometry. The SPADs are mounted in fiber-coupled and free-space coupled packages. The SNSPDs are mounted in a small liquid helium cryostat coupled to single mode fiber optic cables which pass through a hermetic feed-through. The detectors are read out with microwave amplifiers and FPGA-based coincidence electronics. We present progress on measurements of intensity correlations from incoherent sources including gas-discharge lamps and stars with these detectors. From the measured laboratory performance of the correlation system, we estimate the sensitivity to intensity correlations from stars using commercial telescopes and larger existing research telescopes.
NASA Astrophysics Data System (ADS)
Hennessy, Karol; LHCb VELO Upgrade Collaboration
2017-02-01
The upgrade of the LHCb experiment, scheduled for LHC Run-III, scheduled to start in 2021, will transform the experiment to a trigger-less system reading out the full detector at 40 MHz event rate. All data reduction algorithms will be executed in a high-level software farm enabling the detector to run at luminosities of 2×1033 cm-2 s-1. The Vertex Locator (VELO) is the silicon vertex detector surrounding the interaction region. The current detector will be replaced with a hybrid pixel system equipped with electronics capable of reading out at 40 MHz. The upgraded VELO will provide fast pattern recognition and track reconstruction to the software trigger. The silicon pixel sensors have 55×55 μm2 pitch, and are read out by the VeloPix ASIC, from the Timepix/Medipix family. The hottest region will have pixel hit rates of 900 Mhits/s yielding a total data rate of more than 3 Tbit/s for the upgraded VELO. The detector modules are located in a separate vacuum, separated from the beam vacuum by a thin custom made foil. The foil will be manufactured through milling and possibly thinned further by chemical etching. The material budget will be minimised by the use of evaporative CO2 coolant circulating in microchannels within 400 μm thick silicon substrates. The current status of the VELO upgrade is described and latest results from operation of irradiated sensor assemblies are presented.
NASA Astrophysics Data System (ADS)
Dosil Suárez, Álvaro; LHCb VELO Upgrade Group
2016-07-01
The upgrade of the LHCb experiment, planned for 2019, will transform the experiment to a trigger-less system reading out the full detector at 40 MHz event rate. All data reduction algorithms will be executed in a high-level software farm. The upgraded detector will run at luminosities of 2×1033 cm-2 s-1 and probe physics beyond the Standard Model in the heavy flavour sector with unprecedented precision. The Vertex Locator (VELO) is the silicon vertex detector surrounding the interaction region. The current detector will be replaced with a hybrid pixel system equipped with electronics capable of reading out at 40 MHz. The detector comprises silicon pixel sensors with 55×55 μm2 pitch, read out by the VeloPix ASIC, based on the TimePix/MediPix family. The hottest region will have pixel hit rates of 900 Mhits/s yielding a total data rate more than 3 Tbit/s for the upgraded VELO. The detector modules are located in a separate vacuum, separated from the beam vacuum by a thin custom made foil. The detector halves are retracted when the beams are injected and closed at stable beams, positioning the first sensitive pixel at 5.1 mm from the beams. The material budget will be minimised by the use of evaporative CO2 coolant circulating in microchannels within 400 μm thick silicon substrates.
The readout electronics for Plastic Scintillator Detector of DAMPE
NASA Astrophysics Data System (ADS)
Kong, Jie; Yang, Haibo; Zhao, Hongyun; Su, Hong; Sun, Zhiyu; Yu, Yuhong; JingZhe, Zhang; Wang, XiaoHui; Liu, Jie; Xiao, Guoqing; Ma, Xinwen
2016-07-01
The Dark Matter Particle Explorer (DAMPE) satellite, which launched in December 2015, is designed to find the evidence of the existence of dark matter particles in the universe via the detection of the high-energy electrons and gamma-ray particles produced possibly by the annihilation of dark matter particles. Plastic Scintillator Detector (PSD) is one of major part of the satellite payload, which is comprised of a crossed pair of layers with 41 plastic scintillator-strips, each read out from both ends by the same Hamamatsu R4443MOD2 photo-multiplier tubes (PMTs). In order to extend linear dynamic range of detector, PMTs read out each plastic scintillator-strip separately with two dynode pickoffs. Therefore, the readout electronics system comprises of four Front-end boards to receive the pulses from 328 PMTs and implement charge measurement, which is based on the Application Specific Integrated Circuit (ASIC) chip VA160, 16 bits ADC and FPGA. The electronics of the detector has been designed following stringent requirements on mechanical and thermal stability, power consumption, radiation hardness and double redundancy. Various experiments are designed and implemented to check the performance of the electronics, some excellent results has been achieved.According to experimental results analysis, it is proved that the readout electronics works well.
2014-01-01
Background Pyrogen detection is of utmost importance in pharmaceutical industry, laboratories and health care institutions. As an alternative to the animal-consuming rabbit pyrogen test or Limulus amoebocyte lysate test, the monocyte activation test was introduced as a gold standard method in the European Pharmacopoeia. However, the monocyte activation test has not gained wide acceptance in practice. Methods We stimulated bovine whole blood with different endotoxin preparations (lipopolysaccharide E.coli 0127:B8 and 0113:H10), as well as the non-endotoxin pyrogens peptidoglycan and lipoteichoic acid. Prostaglandin E2 (PGE2) served as read out. Results Employing PGE2 as read out enabled detection limits of 0.04 EU/ml for lipopolysaccharide 0127:B8, 0.25 EU/ml for lipopolysaccharide 0113:H10 and 10 μg/ml of lipoteichoic acid as well as peptidoglycan. To evaluate the bWBA test system as a possible alternative to the MAT we performed a peer-to-peer comparison of the two methods and confirmed similar sensitivities. Conclusions In conclusion, the bovine whole blood assay (bWBA) reproducibly enabled sensitive detection of endotoxin and non-endotoxin pyrogens and may thus become a viable alternative for pyrogen testing. PMID:25209100
C-RED One : the infrared camera using the Saphira e-APD detector
NASA Astrophysics Data System (ADS)
Greffe, Timothée.; Feautrier, Philippe; Gach, Jean-Luc; Stadler, Eric; Clop, Fabien; Lemarchand, Stephane; Boutolleau, David; Baker, Ian
2016-08-01
Name for Person Card: Observatoire de la Côte d'Azur First Light Imaging' C-RED One infrared camera is capable of capturing up to 3500 full frames per second with a sub-electron readout noise and very low background. This breakthrough has been made possible thanks to the use of an e- APD infrared focal plane array which is a real disruptive technology in imagery. C-RED One is an autonomous system with an integrated cooling system and a vacuum regeneration system. It operates its sensor with a wide variety of read out techniques and processes video on-board thanks to an FPGA. We will show its performances and expose its main features. The project leading to this application has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement N° 673944.
The LHCb trigger and its upgrade
NASA Astrophysics Data System (ADS)
Dziurda, A.; LHCb Trigger Group
2016-07-01
The current LHCb trigger system consists of a hardware level, which reduces the LHC inelastic collision rate of 30 MHz, at which the entire detector is read out. In a second level, implemented in a farm of 20 k parallel-processing CPUs, the event rate is reduced to about 5 kHz. We review the performance of the LHCb trigger system during Run I of the LHC. Special attention is given to the use of multivariate analyses in the High Level Trigger. The major bottleneck for hadronic decays is the hardware trigger. LHCb plans a major upgrade of the detector and DAQ system in the LHC shutdown of 2018, enabling a purely software based trigger to process the full 30 MHz of inelastic collisions delivered by the LHC. We demonstrate that the planned architecture will be able to meet this challenge.
A pulse shape discriminator and an online system for the balloon-borne hard X-ray/gamma-ray detector
NASA Astrophysics Data System (ADS)
Takahashi, T.; Kamae, T.; Tanaka, M.; Gunji, S.; Miyazuki, S.; Tamura, T.; Sekimoto, Y.; Yamaoka, N.; Nishimura, J.; Yajima, N.
Attention is given to a new kind of phoswich counters (the well-type phoswich counter) that will be capable of detecting very low flux hard X-rays/gamma-rays (40-1000 keV) from astronomical objects. A specially designed pulse-shape discriminator (PSD) selects hard X-rays/gamma-rays that has deposited energy only in the detection part. Sixty-four such counters are assembled into an array where each phoswich element acts as an active shield to the neighboring elements too. The ADCs, the TDCs, the hit-pattern latches, and the precision clock are read out by a VME-based online system, stored on an 8-mm video tape, and transmitted to the ground station. The design and performance of the pulse shape discriminator and the online system are described.
Calibration of the Concorde radiation detection instrument and measurements at SST altitude.
DOT National Transportation Integrated Search
1971-06-01
Performance tests were carried out on a solar cosmic radiation detection instrument developed for the Concorde SST. The instrument calibration curve (log dose-rate vs instrument reading) was reasonably linear from 0.004 to 1 rem/hr for both gamma rad...
Improving text comprehension strategies in upper primary school children: a design experiment.
De Corte, E; Verschaffel, L; Van De Ven, A
2001-12-01
With respect to the acquisition of competence in reading, new standards for primary education stress more than before the importance of learning and teaching cognitive and metacognitive strategies that facilitate text comprehension. Therefore, there is a need to design a research-based instructional approach to strategic reading comprehension. The design experiment aimed at developing, implementing and evaluating a research-based, but also practically applicable learning environment for enhancing skilled strategy use in upper primary school children when reading a text. Four text comprehension strategies (activating prior knowledge, clarifying difficult words, making a schematic representation of the text, and formulating the main idea) and a metacognitive strategy (regulating one's own reading process) were trained through a variety of highly interactive instructional techniques, namely modelling, whole class discussion, and small group work in the format of reciprocal teaching. Participants in the study were four experimental 5th grade classes (79 children) and eight comparable control classes (149 pupils). The effects of the learning environment were measured using a pretest-post-test-retention design. Multilevel hierarchical linear regression models were used to analyse the quantitative data of a Reading Strategy Test, a standardised Reading Comprehension Test, a Reading Attitude Scale, a Transfer Test and an interview about strategy use during reading. The data of the Reading Strategy Test, the Transfer Test and the interviews about strategy use showed that the experimental group out-performed the control group in terms of the strategy adoption and application during text reading. Whilst the experimental group also scored higher on the Reading Comprehension Test than the control group, the difference was not significant. This design experiment shows that it is possible to foster pupils' use and transfer of strategic reading comprehension skills in regular classrooms by immersing them in a powerful learning environment. But this intervention does not automatically result in improvement of performance on a standardised reading comprehension test.
Study report on laser storage and retrieval of image data
NASA Technical Reports Server (NTRS)
Becker, C. H.
1976-01-01
The theoretical foundation is presented for a system of real-time nonphotographic and nonmagnetic digital laser storage and retrieval of image data. The system utilizes diffraction-limited laser focusing upon thin metal films, melting elementary holes in the metal films in laser focus. The metal films are encapsulated in rotating flexible mylar discs which act as the permanent storage carries. Equal sized holes encompass two dimensional digital ensembles of information bits which are time-sequentially (bit by bit) stored and retrieved. The bits possess the smallest possible size, defined by the Rayleigh criterion of coherent physical optics. Space and time invariant reflective read-out of laser discs with a small laser, provides access to the stored digital information. By eliminating photographic and magnetic data processing, which characterize the previous state of the art, photographic grain, diffusion, and gamma-distortion do not exist. Similarly, magnetic domain structures, magnetic gaps, and magnetic read-out are absent with a digital laser disc system.
Detection of Kaposi's Sarcoma Associated Herpesvirus Nucleic Acids Using a Smartphone Accessory
Mancuso, Matthew; Cesarman, Ethel; Erickson, David
2014-01-01
Kaposi's sarcoma (KS) is an infectious cancer occurring in immune-compromised patients, caused by Kaposi's sarcoma associated herpesvirus (KSHV). Our vision is to simplify the process of KS diagnosis through the creation of a smartphone based point-of-care system capable of yielding an actionable diagnostic readout starting from a raw biopsy sample. In this work we develop the sensing mechanism for the overall system, a smartphone accessory capable of detecting KSHV nucleic acids. The accessory reads out microfluidic chips filled with a colorimetric nanoparticle assay targeted at KSHV. We calculate that our final device can read out gold nanoparticle solutions with an accuracy of .05 OD, and we demonstrate that it can detect DNA sequences from KSHV down to 1 nM. We believe that through integration with our previously developed components, a smartphone based system like the one studied here can provide accurate detection information, as well as a simple platform for field based clinical diagnosis and research. PMID:25117534
Evaluation of sensitivity and selectivity of piezoresistive cantilever-array sensors
NASA Astrophysics Data System (ADS)
Yoshikawa, Genki; Lang, Hans-Peter; Staufer, Urs; Vettiger, Peter; Sakurai, Toshio; Gerber, Christoph
2008-03-01
Microfabricated cantilever-array sensors have attracted much attention in recent years due to their real-time detection of low concentration of molecules. Since the piezoresistive cantilever-array sensors do not require a bulky and expensive optical read-out system, they possess many advantages compared with optical read-out cantilever-array sensors. They can be miniaturized and integrated into a match-box sized device. In this study, we present the piezoresistive cantilever-array sensor system and evaluate its sensitivity and selectivity using various vapors of molecules, including alkane molecules with different chain length from 5 (n-pentane) to 12 (n-dodecane). Piezoresistive cantilevers were coated with different polymers (PVP, PAAM, PEI, and PVA) using an inkjet spotter. Each cantilever has a reference cantilever, constituting a Wheatstone-bridge. Each vapor was mixed with a constant nitrogen gas flow and introduced into the measurement chamber. According to the principle component analysis of data obtained, each molecule can be clearly distinguished from others. We also confirmed that this piezoresistive cantilever-array sensor system has sub-ppm sensitivity.
Ultra Small Integrated Optical Fiber Sensing System
Van Hoe, Bram; Lee, Graham; Bosman, Erwin; Missinne, Jeroen; Kalathimekkad, Sandeep; Maskery, Oliver; Webb, David J.; Sugden, Kate; Van Daele, Peter; Van Steenberge, Geert
2012-01-01
This paper introduces a revolutionary way to interrogate optical fiber sensors based on fiber Bragg gratings (FBGs) and to integrate the necessary driving optoelectronic components with the sensor elements. Low-cost optoelectronic chips are used to interrogate the optical fibers, creating a portable dynamic sensing system as an alternative for the traditionally bulky and expensive fiber sensor interrogation units. The possibility to embed these laser and detector chips is demonstrated resulting in an ultra thin flexible optoelectronic package of only 40 μm, provided with an integrated planar fiber pigtail. The result is a fully embedded flexible sensing system with a thickness of only 1 mm, based on a single Vertical-Cavity Surface-Emitting Laser (VCSEL), fiber sensor and photodetector chip. Temperature, strain and electrodynamic shaking tests have been performed on our system, not limited to static read-out measurements but dynamically reconstructing full spectral information datasets.
Swanson, H Lee; Jerman, Olga
2007-04-01
This 3-year longitudinal study determined whether (a) subgroups of children with reading disabilities (RD) (children with RD only, children with both reading and arithmetic deficits, and low verbal IQ readers) and skilled readers varied in working memory (WM) and short-term memory (STM) growth and (b) whether growth in an executive system and/or a phonological storage system mediated growth in reading performance. A battery of memory and reading measures was administered to 84 children (11-17 years of age) across three testing waves spaced 1 year apart. The results showed that skilled readers yielded higher WM growth estimates than did the RD groups. No significant differentiation among subgroups of children with RD on growth measures emerged. Hierarchical linear modeling showed that WM (controlled attention), rather than STM (phonological loop), was related to growth in reading comprehension and reading fluency. The results support the notion that deficient growth in the executive component of WM underlies RD.
ERIC Educational Resources Information Center
Tarr, C. Anita
1997-01-01
Argues that, in "Island of the Blue Dolphins," Scott O'Dell offers a skeleton main character (Karana). Contends that O'Dell has sketched Karana as a stereotype and that readers complete her characterization, filling out the skeleton by perpetuating the stereotypes. Points out this trading of stereotype for true character development in…
Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma
Murata, Noriaki; Fukuchi, Takeo
2017-01-01
Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478
Automation of immunohistochemical evaluation in breast cancer using image analysis
Prasad, Keerthana; Tiwari, Avani; Ilanthodi, Sandhya; Prabhu, Gopalakrishna; Pai, Muktha
2011-01-01
AIM: To automate breast cancer diagnosis and to study the inter-observer and intra-observer variations in the manual evaluations. METHODS: Breast tissue specimens from sixty cases were stained separately for estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor-2 (HER-2/neu). All cases were assessed by manual grading as well as image analysis. The manual grading was performed by an experienced expert pathologist. To study inter-observer and intra-observer variations, we obtained readings from another pathologist as the second observer from a different laboratory who has a little less experience than the first observer. We also took a second reading from the second observer to study intra-observer variations. Image analysis was carried out using in-house developed software (TissueQuant). A comparison of the results from image analysis and manual scoring of ER, PR and HER-2/neu was also carried out. RESULTS: The performance of the automated analysis in the case of ER, PR and HER-2/neu expressions was compared with the manual evaluations. The performance of the automated system was found to correlate well with the manual evaluations. The inter-observer variations were measured using Spearman correlation coefficient r and 95% confidence interval. In the case of ER expression, Spearman correlation r = 0.53, in the case of PR expression, r = 0.63, and in the case of HER-2/neu expression, r = 0.68. Similarly, intra-observer variations were also measured. In the case of ER, PR and HER-2/neu expressions, r = 0.46, 0.66 and 0.70, respectively. CONCLUSION: The automation of breast cancer diagnosis from immunohistochemically stained specimens is very useful for providing objective and repeatable evaluations. PMID:21611095
Language deficits in poor comprehenders: a case for the simple view of reading.
Catts, Hugh W; Adlof, Suzanne M; Ellis Weismer, Susan
2006-04-01
To examine concurrently and retrospectively the language abilities of children with specific reading comprehension deficits ("poor comprehenders") and compare them to typical readers and children with specific decoding deficits ("poor decoders"). In Study 1, the authors identified 57 poor comprehenders, 27 poor decoders, and 98 typical readers on the basis of 8th-grade reading achievement. These subgroups' performances on 8th-grade measures of language comprehension and phonological processing were investigated. In Study 2, the authors examined retrospectively subgroups' performances on measures of language comprehension and phonological processing in kindergarten, 2nd, and 4th grades. Word recognition and reading comprehension in 2nd and 4th grades were also considered. Study 1 showed that poor comprehenders had concurrent deficits in language comprehension but normal abilities in phonological processing. Poor decoders were characterized by the opposite pattern of language abilities. Study 2 results showed that subgroups had language (and word recognition) profiles in the earlier grades that were consistent with those observed in 8th grade. Subgroup differences in reading comprehension were inconsistent across grades but reflective of the changes in the components of reading comprehension over time. The results support the simple view of reading and the phonological deficit hypothesis. Furthermore, the findings indicate that a classification system that is based on the simple view has advantages over standard systems that focus only on word recognition and/or reading comprehension.
Lee, Young Han
2012-01-01
The objectives are (1) to introduce an easy open-source macro program as connection software and (2) to illustrate the practical usages in radiologic reading environment by simulating the radiologic reading process. The simulation is a set of radiologic reading process to do a practical task in the radiologic reading room. The principal processes are: (1) to view radiologic images on the Picture Archiving and Communicating System (PACS), (2) to connect the HIS/EMR (Hospital Information System/Electronic Medical Record) system, (3) to make an automatic radiologic reporting system, and (4) to record and recall information of interesting cases. This simulation environment was designed by using open-source macro program as connection software. The simulation performed well on the Window-based PACS workstation. Radiologists practiced the steps of the simulation comfortably by utilizing the macro-powered radiologic environment. This macro program could automate several manual cumbersome steps in the radiologic reading process. This program successfully acts as connection software for the PACS software, EMR/HIS, spreadsheet, and other various input devices in the radiologic reading environment. A user-friendly efficient radiologic reading environment could be established by utilizing open-source macro program as connection software. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Thompson, Sheila; Provasnik, Stephen; Kastberg, David; Ferraro, David; Lemanski, Nita; Roey, Stephen; Jenkins, Frank
2012-01-01
The Progress in International Reading Literacy Study (PIRLS) is an international comparative study of student achievement. In 2011, PIRLS was administered to nationally representative samples of 4th-grade students in 53 education systems around the world. The PIRLS assessment measures student performance on a combined reading literacy scale, as…
Modeling high signal-to-noise ratio in a novel silicon MEMS microphone with comb readout
NASA Astrophysics Data System (ADS)
Manz, Johannes; Dehe, Alfons; Schrag, Gabriele
2017-05-01
Strong competition within the consumer market urges the companies to constantly improve the quality of their devices. For silicon microphones excellent sound quality is the key feature in this respect which means that improving the signal-to-noise ratio (SNR), being strongly correlated with the sound quality is a major task to fulfill the growing demands of the market. MEMS microphones with conventional capacitive readout suffer from noise caused by viscous damping losses arising from perforations in the backplate [1]. Therefore, we conceived a novel microphone design based on capacitive read-out via comb structures, which is supposed to show a reduction in fluidic damping compared to conventional MEMS microphones. In order to evaluate the potential of the proposed design, we developed a fully energy-coupled, modular system-level model taking into account the mechanical motion, the slide film damping between the comb fingers, the acoustic impact of the package and the capacitive read-out. All submodels are physically based scaling with all relevant design parameters. We carried out noise analyses and due to the modular and physics-based character of the model, were able to discriminate the noise contributions of different parts of the microphone. This enables us to identify design variants of this concept which exhibit a SNR of up to 73 dB (A). This is superior to conventional and at least comparable to high-performance variants of the current state-of-the art MEMS microphones [2].
ERIC Educational Resources Information Center
Marks, Gary N.
2008-01-01
In most countries, girls perform better than boys in reading but worse in mathematics. However, there is much variation between countries. Explanations for the gender gaps include the organisation of the school system, students' expectations and macro-societal factors. The purpose of this paper is to account for gender differences in both reading…
A front-end read out chip for the OPERA scintillator tracker
NASA Astrophysics Data System (ADS)
Lucotte, A.; Bondil, S.; Borer, K.; Campagne, J. E.; Cazes, A.; Hess, M.; de La Taille, C.; Martin-Chassard, G.; Raux, L.; Repellin, J. P.
2004-04-01
Multi-anode photomultipliers H7546 are used to readout signal from the OPERA Scintillator Tracker (CERN/SPSC 2000-028, SPSC/P318, LNGSP 25/2000; CERN/SPSC 2001-025, SPSC/M668, LNGS-EXP30/2001). A 32-channel front-end Read Out Chip prototype accommodating the H7546 has been designed at LAL. This device features a low-noise, variable gain preamplifier to correct for multi-anode non-uniformity, an auto-trigger capability 100% efficient at a 0.3 photo-electron, and a charge measurement extending over a large dynamic range [0-100] photo-electrons. In this article we describe the ASIC architecture that is being implemented for the Target Tracker in OPERA, with a special emphasis put on the designs and the measured performance.
Yang, Jianfeng; Shu, Hua; McCandliss, Bruce D.; Zevin, Jason D.
2013-01-01
Learning to read any language requires learning to map among print, sound and meaning. Writing systems differ in a number of factors that influence both the ease and rate with which reading skill can be acquired, as well as the eventual division of labor between phonological and semantic processes. Further, developmental reading disability manifests differently across writing systems, and may be related to different deficits in constitutive processes. Here we simulate some aspects of reading acquisition in Chinese and English using the same model architecture for both writing systems. The contribution of semantic and phonological processing to literacy acquisition in the two languages is simulated, including specific effects of phonological and semantic deficits. Further, we demonstrate that similar patterns of performance are observed when the same model is trained on both Chinese and English as an "early bilingual." The results are consistent with the view that reading skill is acquired by the application of statistical learning rules to mappings among print, sound and meaning, and that differences in the typical and disordered acquisition of reading skill between writing systems are driven by differences in the statistical patterns of the writing systems themselves, rather than differences in cognitive architecture of the learner. PMID:24587693
Clinical evaluation of a noninvasive alarm system for nocturnal hypoglycemia.
Skladnev, Victor N; Ghevondian, Nejhdeh; Tarnavskii, Stanislav; Paramalingam, Nirubasini; Jones, Timothy W
2010-01-01
The aim of this study was to evaluate the performance of a prototype noninvasive alarm system (HypoMon) for the detection of nocturnal hypoglycemia. A prospective cohort study evaluated an alarm system that included a sensor belt, a radio frequency transmitter for chest belt signals, and a receiver. The receiver incorporated integrated "real-time" algorithms designed to recognize hypoglycemia "signatures" in the physiological parameters monitored by the sensor belt. Fifty-two children and young adults with type 1 diabetes mellitus (T1DM) participated in this blinded, prospective, in-clinic, overnight study. Participants had a mean age of 16 years (standard deviation 2.1, range 12-20 years) and were asked to follow their normal meal and insulin routines for the day of the study. Participants had physiological parameters monitored overnight by a single HypoMon system. Their BG levels were also monitored overnight at regular intervals via an intravenous cannula and read on two independent Yellow Springs Instruments analyzers. Hypoglycemia was not induced by any manipulations of diabetes management, rather the subjects were monitored overnight for "natural" occurrences of hypoglycemia. Performance analyses included comparing HypoMon system alarm times with allowed time windows associated with each hypoglycemic event. The primary recognition algorithm in the prototype alarm system performed at a level consistent with expectations based on prior user surveys. The HypoMon system correctly recognized 8 out of the 11 naturally occurring overnight hypoglycemic events and falsely alarmed on 13 out of the remaining 41 normal nights [sensitivity 73% (8/11), specificity 68% (28/41), positive predictive value 38%,negative predictive value 90%]. The prototype HypoMon shows potential as an adjunct method for noninvasive overnight monitoring for hypoglycemia events in young people with T1DM. 2010 Diabetes Technology Society.
Seong, Nak Jong; Kim, Bohyoung; Lee, Sungmin; Park, Hee Sun; Kim, Hyuk Jung; Woo, Hyunsik; Kang, Heung-Sik; Lee, Kyoung Ho
2014-07-01
The purpose of this study was to simulate a mobile consultation in patients with inconclusive diagnosis of appendicitis made by on-call radiologists, as well as to measure the diagnostic confidence and performance of the mobile consultation. Two off-site abdominal radiologists interpreted the CT images from 68 patients (including 29 patients with confirmed appendicitis) on a smart-phone for whom the preliminary CT reports by 25 in-house on-call radiologists were inconclusive. The smartphone readings were compared with the preliminary reports by on-call radiologists and with the original final reports by in-house abdominal radiologists. Heat maps, kappa statistics, Wilcoxon signed-rank tests, and ROC curves were used for data analysis. The heat maps and kappa statistics showed that the smartphone readings were more similar to the final reports than to the preliminary reports. In diagnosing or ruling out appendicitis, the smartphone readings were more confident than the preliminary reports (p ≤ 0.01) and did not significantly differ in diagnostic confidence from the final reports (p ≥ 0.19). The AUCs of the smartphone readings (0.91 and 0.92) did not differ significantly from those of the preliminary (0.85) or final (0.97) reports (p ≥ 0.09). With the given study sample, the diagnostic performance of the off-site smartphone readings did not differ significantly from that of the in-house preliminary reports. However, the smartphone readings provided higher diagnostic confidence than the preliminary reports.
ATLAS Tile calorimeter calibration and monitoring systems
NASA Astrophysics Data System (ADS)
Chomont, Arthur; ATLAS Collaboration
2017-11-01
The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises cesium radioactive sources, Laser and charge injection elements, and allows for monitoring and equalization of the calorimeter response at each stage of the signal production, from scintillation light to digitization. Based on LHC Run 1 experience, several calibration systems were improved for Run 2. The lessons learned, the modifications, and the current LHC Run 2 performance are discussed.
Liederman, Jacqueline; McGraw Fisher, Janet; Wu, Meng-Hung
2012-01-01
We examined how effective connectivity into and out of the left and right temporoparietal areas (TPAs) to/from other key cortical areas affected phonological decoding in 7 dyslexic readers (DRs) and 10 typical readers (TRs) who were young adults. Granger causality was used to compute the effective connectivity of the preparatory network 500 ms prior to presentation of nonwords that required phonological decoding. Neuromagnetic activity was analyzed within the low, medium, and high beta and gamma subbands. A mixed-model analysis determined whether connectivity to or from the left and right TPAs differed across connectivity direction (in vs. out), brain areas (right and left inferior frontal and ventral occipital–temporal and the contralateral TPA), reading group (DR vs. TR), and/or task performance. Within the low beta subband, better performance was associated with increased influence of the left TPA on other brain areas across both reading groups and poorer performance was associated with increased influence of the right TPA on other brain areas for DRs only. DRs were also found to have an increase in high gamma connectivity between the left TPA and other brain areas. This study suggests that hierarchal network structure rather than connectivity per se is important in determining phonological decoding performance. PMID:21980019
Technical considerations for implementation of x-ray CT polymer gel dosimetry.
Hilts, M; Jirasek, A; Duzenli, C
2005-04-21
Gel dosimetry is the most promising 3D dosimetry technique in current radiation therapy practice. X-ray CT has been shown to be a feasible method of reading out polymer gel dosimeters and, with the high accessibility of CT scanners to cancer hospitals, presents an exciting possibility for clinical implementation of gel dosimetry. In this study we report on technical considerations for implementation of x-ray CT polymer gel dosimetry. Specifically phantom design, CT imaging methods, imaging time requirements and gel dose response are investigated. Where possible, recommendations are made for optimizing parameters to enhance system performance. The dose resolution achievable with an optimized system is calculated given voxel size and imaging time constraints. Results are compared with MRI and optical CT polymer gel dosimetry results available in the literature.
R&D of the CEPC scintillator-tungsten ECAL
NASA Astrophysics Data System (ADS)
Dong, M. Y.
2018-03-01
The circular electron and positron collider (CEPC) was proposed as a future Higgs factory. To meet the physics requirements, a particle flow algorithm-oriented calorimeter system with high energy resolution and precise reconstruction is considered. A sampling calorimeter with scintillator-tungsten sandwich structure is selected as one of the electromagnetic calorimeter (ECAL) options due to its good performance and relatively low cost. We present the design, the test and the optimization of the scintillator module read out by silicon photomultiplier (SiPM), including the design and the development of the electronics. To estimate the performance of the scintillator and SiPM module for particles with different energy, the beam test of a mini detector prototype without tungsten shower material was performed at the E3 beams in Institute of High Energy Physics (IHEP). The results are consistent with the expectation. These studies provide a reference and promote the development of particle flow electromagnetic calorimeter for the CEPC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milic, A.
The ATLAS Liquid Argon calorimeters are designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |η|<3.2, and for hadronic calorimetry in the region from |η|=1.5 to |η|=4.9. Although the nominal LHC experimental programme is still in progress, an upgrade of the read-out electronics is being launched to cope with luminosities of up to 3x10{sup 34} cm{sup -2}s{sup -1}, which are beyond the original design by a factor of 3. An improved spatial granularity of the triggermore » primitives is therefore proposed in order to improve the identification performance for trigger signatures, like electrons, photons, tau leptons, jets, total and missing energy, at high background rejection rates. For the upgrade Phase-1 in 2018, new LAr Trigger Digitizer Boards (LTDB) are being designed to receive higher granularity signals, digitize them on detector and send them via fast optical links to a new LAr digital processing system (LDPS). The LDPS applies a digital filtering and identifies significant energy depositions in each trigger channel. The refined trigger primitives are then transmitted to the first level trigger system to extract improved trigger signatures. The read-out of the trigger signals will process 34000 so-called Super Cells at every LHC bunch-crossing at a frequency of 40 MHz. The new LTDB on-detector electronics is designed to be radiation tolerant in order to be operated for the remaining live-time of the ATLAS detector up to a total luminosity of 3000 fb{sup -1}. For the analog-to-digital conversion (12-bit ADC at 40 MSPS), the data serialization and the fast optical link (5.44 Gb/s) custom components have been developed. They have been qualified for the expected radiation environment of a total ionization dose of 1.3 kGy and a hadron fluence of 6 x 10{sup 13} h/cm{sup 2} with energies above 20 MeV. For the digital components like the ADC, cross-sections for single event effects have been determined. This talk will present R and D results from tests of the radiation tolerant components, the fast data processing electronics and prototypes of the LTDB and LDPS boards. First experience from a Demonstrator setup will be reported, in which about 1/10 of the full Super Cell readout will be equipped with prototype versions of the LTDB and LDPS boards. The Demonstrator will be operated in parallel to the regular ATLAS trigger read-out during the upcoming LHC run. (authors)« less
Data Quality Monitoring System for New GEM Muon Detectors for the CMS Experiment Upgrade
NASA Astrophysics Data System (ADS)
King, Robert; CMS Muon Group Team
2017-01-01
The Gas Electron Multiplier (GEM) detectors are novel detectors designed to improve the muon trigger and tracking performance in CMS experiment for the high luminosity upgrade of the LHC. Partial installation of GEM detectors is planned during the 2016-2017 technical stop. Before the GEM system is installed underground, its data acquisition (DAQ) electronics must be thoroughly tested. The DAQ system includes several commercial and custom-built electronic boards running custom firmware. The front-end electronics are radiation-hard and communicate via optical fibers. The data quality monitoring (DQM) software framework has been designed to provide online verification of the integrity of the data produced by the detector electronics, and to promptly identify potential hardware or firmware malfunctions in the system. Local hits reconstruction and clustering algorithms allow quality control of the data produced by each GEM chamber. Once the new detectors are installed, the DQM will monitor the stability and performance of the system during normal data-taking operations. We discuss the design of the DQM system, the software being developed to read out and process the detector data, and the methods used to identify and report hardware and firmware malfunctions of the system.
Evaluation of the performance of a novel system for continuous glucose monitoring.
Zschornack, Eva; Schmid, Christina; Pleus, Stefan; Link, Manuela; Klötzer, Hans-Martin; Obermaier, Karin; Schoemaker, Michael; Strasser, Monika; Frisch, Gerhard; Schmelzeisen-Redeker, Günther; Haug, Cornelia; Freckmann, Guido
2013-07-01
The performance of a continuous glucose monitoring (CGM) system in the early stage of development was assessed in an inpatient setting that simulates daily life conditions of people with diabetes. Performance was evaluated at low glycemic, euglycemic, and high glycemic ranges as well as during phases with rapid glucose excursions. Each of the 30 participants with type 1 diabetes (15 female, age 47 ± 12 years, hemoglobin A1c 7.7% ± 1.3%) wore two sensors of the prototype system in parallel for 7 days. Capillary blood samples were measured at least 16 times per day (at least 15 times per daytime and at least once per night). On two subsequent study days, glucose excursions were induced. For performance evaluation, the mean absolute relative difference (MARD) between CGM readings and paired capillary blood glucose readings and precision absolute relative difference (PARD), i.e., differences between paired CGM readings were calculated. Overall aggregated MARD was 9.2% and overall aggregated PARD was 7.5%. During induced glucose excursions, MARD was 10.9% and PARD was 7.8%. Lowest MARD (8.5%) and lowest PARD (6.4%) were observed in the high glycemic range (euglycemic range, MARD 9.1% and PARD 7.4%; low glycemic range, MARD 12.3% and PARD 12.4%). The performance of this prototype CGM system was, particularly in the hypoglycemic range and during phases with rapid glucose fluctuations, better than performance data reported for other commercially available systems. In addition, performance of this prototype sensor was noticeably constant over the whole study period. This prototype system is not yet approved, and performance of this CGM system needs to be further assessed in clinical studies. © 2013 Diabetes Technology Society.
Thermal (Silicon Diode) Data Acquisition System
NASA Technical Reports Server (NTRS)
Kegley, Jeffrey
2008-01-01
Marshall Space Flight Center's X-ray Calibration Facility (XRCF) has been performing cryogenic testing to 20 Kelvin since 1999. Two configurations for acquiring data from silicon diode temperature sensors have been implemented at the facility. The facility's environment is recorded via a data acquisition system capable of reading up to 60 silicon diodes. Test article temperature is recorded by a second data acquisition system capable of reading 150+ silicon diodes. The specifications and architecture of both systems will be presented.
Thermal (Silicon Diode) Data Acquisition Systems
NASA Technical Reports Server (NTRS)
Wright, Ernest; Kegley, Jeff
2008-01-01
Marshall Space Flight Center s X-ray Cryogenic Facility (XRCF) has been performing cryogenic testing to 20 Kelvin since 1999. Two configurations for acquiring data from silicon diode temperature sensors have been implemented at the facility. The facility's environment is recorded via a data acquisition system capable of reading up to 60 silicon diodes. Test article temperature is recorded by a second data acquisition system capable of reading 150+ silicon diodes. The specifications and architecture of both systems will be presented.
Joo, Sung Jun; White, Alex L; Strodtman, Douglas J; Yeatman, Jason D
2018-06-01
Reading is a complex process that involves low-level visual processing, phonological processing, and higher-level semantic processing. Given that skilled reading requires integrating information among these different systems, it is likely that reading difficulty-known as dyslexia-can emerge from impairments at any stage of the reading circuitry. To understand contributing factors to reading difficulties within individuals, it is necessary to diagnose the function of each component of the reading circuitry. Here, we investigated whether adults with dyslexia who have impairments in visual processing respond to a visual manipulation specifically targeting their impairment. We collected psychophysical measures of visual crowding and tested how each individual's reading performance was affected by increased text-spacing, a manipulation designed to alleviate severe crowding. Critically, we identified a sub-group of individuals with dyslexia showing elevated crowding and found that these individuals read faster when text was rendered with increased letter-, word- and line-spacing. Our findings point to a subtype of dyslexia involving elevated crowding and demonstrate that individuals benefit from interventions personalized to their specific impairments. Copyright © 2018 Elsevier Ltd. All rights reserved.
Electron-Nuclear Dynamics in a Quantum Dot under Nonunitary Electron Control
2011-07-20
relevant because inco - herent interactions are needed to initialize and read out the system. These experiments in quantum dots (QDs) ob- served dynamic...relaxation process is several orders of magnitude faster than what is used in Refs. [3,5]. The system we consider is a single electron trapped in a QD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sina, S; Sadeghi, M; Faghihi, R
2014-06-01
Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDsmore » were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading.« less
Reading difficulties in Spanish adults with dyslexia.
Suárez-Coalla, Paz; Cuetos, Fernando
2015-04-01
Recent studies show that dyslexia persists into adulthood, even in highly educated and well-read people. The main characteristic that adults with dyslexia present is a low speed when reading. In Spanish, a shallow orthographic system, no studies about adults with dyslexia are available; and it is possible that the consistency of the orthographic system favours the reading fluency. The aim of this study was to get an insight of the reading characteristics of Spanish adults with dyslexia and also to infer the reading strategies that they are using. For that purpose, a group of 30 dyslexics (M age = 32 years old) and an age-matched group of 30 adults without reading disabilities completed several phonological and reading tasks: phonological awareness tasks, rapid automatic naming, lexical decision, word and pseudoword reading, letter detection and text reading. The results showed that highly educated Spanish dyslexics performed significantly worse than the control group in the majority of the tasks. Specifically, they showed difficulties reading long pseudowords, indicating problems in automating the grapheme-phoneme rules, but they also seem to present difficulties reading words, which indicate problems with the lexical route. It seems that the Spanish dyslexic adults, as in deep orthographies, continue having difficulties in phonological awareness tasks, rapid naming and reading.
Visual and binocular status in elementary school children with a reading problem.
Christian, Lisa W; Nandakumar, Krithika; Hrynchak, Patricia K; Irving, Elizabeth L
2017-11-21
This descriptive study provides a summary of the binocular anomalies seen in elementary school children identified with reading problems. A retrospective chart review of all children identified with reading problems and seen by the University of Waterloo, Optometry Clinic, from September 2012 to June 2013. Files of 121 children (mean age 8.6 years, range 6-14 years) were reviewed. No significant refractive error was found in 81% of children. Five and 8 children were identified as strabismic at distance and near respectively. Phoria test revealed 90% and 65% of patients had normal distance and near phoria. Near point of convergencia (NPC) was <5cm in 68% of children, and 77% had stereoacuity of ≤40seconds of arc. More than 50% of the children had normal fusional vergence ranges except for near positive fusional vergencce (base out) break (46%). Tests for accommodation showed 91% of children were normal for binocular facility, and approximately 70% of children had an expected accuracy of accommodation. Findings indicate that some children with an identified reading problem also present with abnormal binocular test results compared to published normal values. Further investigation should be performed to investigate the relationship between binocular vision function and reading performance. Crown Copyright © 2017. Published by Elsevier España, S.L.U. All rights reserved.
ATLAS tile calorimeter cesium calibration control and analysis software
NASA Astrophysics Data System (ADS)
Solovyanov, O.; Solodkov, A.; Starchenko, E.; Karyukhin, A.; Isaev, A.; Shalanda, N.
2008-07-01
An online control system to calibrate and monitor ATLAS Barrel hadronic calorimeter (TileCal) with a movable radioactive source, driven by liquid flow, is described. To read out and control the system an online software has been developed, using ATLAS TDAQ components like DVS (Diagnostic and Verification System) to verify the hardware before running, IS (Information Server) for data and status exchange between networked computers, and other components like DDC (DCS to DAQ Connection), to connect to PVSS-based slow control systems of Tile Calorimeter, high voltage and low voltage. A system of scripting facilities, based on Python language, is used to handle all the calibration and monitoring processes from hardware perspective to final data storage, including various abnormal situations. A QT based graphical user interface to display the status of the calibration system during the cesium source scan is described. The software for analysis of the detector response, using online data, is discussed. Performance of the system and first experience from the ATLAS pit are presented.
ERIC Educational Resources Information Center
Espin, Christine; Wallace, Teri; Lembke, Erica; Campbell, Heather; Long, Jeffrey D.
2010-01-01
In this study, we examined the reliability and validity of curriculum-based measures (CBM) in reading for indexing the performance of secondary-school students. Participants were 236 eighth-grade students (134 females and 102 males) in the classrooms of 17 English teachers. Students completed 1-, 2-, and 3-minute reading aloud and 2-, 3-, and…
Radiation imaging with optically read out GEM-based detectors
NASA Astrophysics Data System (ADS)
Brunbauer, F. M.; Lupberger, M.; Oliveri, E.; Resnati, F.; Ropelewski, L.; Streli, C.; Thuiner, P.; van Stenis, M.
2018-02-01
Modern imaging sensors allow for high granularity optical readout of radiation detectors such as MicroPattern Gaseous Detectors (MPGDs). Taking advantage of the high signal amplification factors achievable by MPGD technologies such as Gaseous Electron Multipliers (GEMs), highly sensitive detectors can be realised and employing gas mixtures with strong scintillation yield in the visible wavelength regime, optical readout of such detectors can provide high-resolution event representations. Applications from X-ray imaging to fluoroscopy and tomography profit from the good spatial resolution of optical readout and the possibility to obtain images without the need for extensive reconstruction. Sensitivity to low-energy X-rays and energy resolution permit energy resolved imaging and material distinction in X-ray fluorescence measurements. Additionally, the low material budget of gaseous detectors and the possibility to couple scintillation light to imaging sensors via fibres or mirrors makes optically read out GEMs an ideal candidate for beam monitoring detectors in high energy physics as well as radiotherapy. We present applications and achievements of optically read out GEM-based detectors including high spatial resolution imaging and X-ray fluorescence measurements as an alternative readout approach for MPGDs. A detector concept for low intensity applications such as X-ray crystallography, which maximises detection efficiency with a thick conversion region but mitigates parallax-induced broadening is presented and beam monitoring capabilities of optical readout are explored. Augmenting high resolution 2D projections of particle tracks obtained with optical readout with timing information from fast photon detectors or transparent anodes for charge readout, 3D reconstruction of particle trajectories can be performed and permits the realisation of optically read out time projection chambers. Combining readily available high performance imaging sensors with compatible scintillating gases and the strong signal amplification factors achieved by MPGDs makes optical readout an attractive alternative to the common concept of electronic readout of radiation detectors. Outstanding signal-to-noise ratios and robustness against electronic noise allow unprecedented imaging capabilities for various applications in fields ranging from high energy physics to medical instrumentation.
Design of a laser scanner for a digital mammography system.
Rowlands, J A; Taylor, J E
1996-05-01
We have developed a digital readout system for radiographic images using a scanning laser beam. In this system, electrostatic charge images on amorphous selenium (alpha-Se) plates are read out using photo-induced discharge (PID). We discuss the design requirements of a laser scanner for the PID system and describe its construction from commercially available components. The principles demonstrated can be adapted to a variety of digital imaging systems.
Kuchma, V R; Teksheva, L M; Vyatleva, O A; Kurgansky, A M
2013-01-01
A comparison of the legibility of the three different media: paper personal computer (LCD) and the e-reader in schoolchildren (12-14 years of age) was performed. Comprehensive assessment of the reading performance (speed of reading aloud, the number of errors in reading, and integral indicator of the degree of difficulty of visual task), its physiological value (according to data of EEG, EOG and ECG), and subjective preference of type of media by the schoolchildren showed that by the sum of signs e-reader occupies an intermediate position between printed text and the computer screen. The effect of increased emotional intensity of using e-reader (increased motivation), which is manifested in the preservation of the sympathetic nervous system activation after the reading, was obtained. The necessity of additional research has been shown.
NASA Astrophysics Data System (ADS)
Casas, Ricard; Cardiel-Sas, Laia; Castander, Francisco J.; Jiménez, Jorge; de Vicente, Juan
2014-08-01
The focal plane of the PAU camera is composed of eighteen 2K x 4K CCDs. These devices, plus four spares, were provided by the Japanese company Hamamatsu Photonics K.K. with type no. S10892-04(X). These detectors are 200 μm thick fully depleted and back illuminated with an n-type silicon base. They have been built with a specific coating to be sensitive in the range from 300 to 1,100 nm. Their square pixel size is 15 μm. The read-out system consists of a Monsoon controller (NOAO) and the panVIEW software package. The deafualt CCD read-out speed is 133 kpixel/s. This is the value used in the calibration process. Before installing these devices in the camera focal plane, they were characterized using the facilities of the ICE (CSIC- IEEC) and IFAE in the UAB Campus in Bellaterra (Barcelona, Catalonia, Spain). The basic tests performed for all CCDs were to obtain the photon transfer curve (PTC), the charge transfer efficiency (CTE) using X-rays and the EPER method, linearity, read-out noise, dark current, persistence, cosmetics and quantum efficiency. The X-rays images were also used for the analysis of the charge diffusion for different substrate voltages (VSUB). Regarding the cosmetics, and in addition to white and dark pixels, some patterns were also found. The first one, which appears in all devices, is the presence of half circles in the external edges. The origin of this pattern can be related to the assembly process. A second one appears in the dark images, and shows bright arcs connecting corners along the vertical axis of the CCD. This feature appears in all CCDs exactly in the same position so our guess is that the pattern is due to electrical fields. Finally, and just in two devices, there is a spot with wavelength dependence whose origin could be the result of a defectous coating process.
NASA Astrophysics Data System (ADS)
Bisanz, T.; Große-Knetter, J.; Quadt, A.; Rieger, J.; Weingarten, J.
2017-08-01
The upgrade to the High Luminosity Large Hadron Collider will increase the instantaneous luminosity by more than a factor of 5, thus creating significant challenges to the tracking systems of all experiments. Recent advancement of active pixel detectors designed in CMOS processes provide attractive alternatives to the well-established hybrid design using passive sensors since they allow for smaller pixel sizes and cost effective production. This article presents studies of a high-voltage CMOS active pixel sensor designed for the ATLAS tracker upgrade. The sensor is glued to the read-out chip of the Insertable B-Layer, forming a capacitively coupled pixel detector. The pixel pitch of the device under test is 33× 125 μm2, while the pixels of the read-out chip have a pitch of 50× 250 μm2. Three pixels of the CMOS device are connected to one read-out pixel, the information of which of these subpixels is hit is encoded in the amplitude of the output signal (subpixel encoding). Test beam measurements are presented that demonstrate the usability of this subpixel encoding scheme.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paumel, Kevin; Lhuillier, Christian
2015-07-01
Identifying subassemblies by ultrasound is a method that is being considered to prevent handling errors in sodium fast reactors. It is based on the reading of a code (aligned notches) engraved on the subassembly head by an emitting/receiving ultrasonic sensor. This reading is carried out in sodium with high temperature transducers. The resulting one-dimensional C-scan can be likened to a binary code expressing the subassembly type and number. The first test performed in water investigated two parameters: width and depth of the notches. The code remained legible for notches as thin as 1.6 mm wide. The impact of the depthmore » seems minor in the range under investigation. (authors)« less
Review of the development of diamond radiation sensors
NASA Astrophysics Data System (ADS)
Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P. F.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L. S.; Palmieri, V. G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.; RD42 Collaboration
1999-09-01
Diamond radiation sensors produced by chemical vapour deposition are studied for the application as tracking detectors in high luminosity experiments. Sensors with a charge collection distance up to 250 μm have been manufactured. Their radiation hardness has been studied with pions, proton and neutrons up to fluences of 1.9×10 15 π cm -2, 5×10 15 p cm -2 and 1.35×10 15 n cm -2, respectively. Diamond micro-strip detectors with 50 μm pitch have been exposed in a high-energy test beam in order to investigate their charge collection properties. The measured spatial resolution using a centre-of-gravity position finding algorithm corresponds to the digital resolution for this strip pitch. First results from a strip tracker with a 2×4 cm 2 surface area are reported as well as the performance of a diamond tracker read out by radiation-hard electronics with 25 ns shaping time. Diamond pixel sensors have been prepared to match the geometries of the recently available read-out chip prototypes for ATLAS and CMS. Beam test results are shown from a diamond detector bump-bonded to an ATLAS prototype read-out. They demonstrate a 98% bump-bonding efficiency and a digital resolution in both dimensions.
The Relationship between Iranian EFL Learners' Stress and Their Reading Comprehension
ERIC Educational Resources Information Center
Peyman, Somayeh; Sadighi, Firooz
2011-01-01
This investigation intended to find out the relationship between EFL learners' stress and their reading comprehension. The subjects who included ninety EFL juniors from Shiraz Azad University were asked to answer a standardized reading comprehension test and a stress questionnaire. After finding out the results of stress questionnaire, 10% of the…
Reciprocal Peer Tutoring and Repeated Reading: Increasing Practicality Using Student Groups
ERIC Educational Resources Information Center
Oddo, Maria; Barnett, David W.; Hawkins, Renee O.; Musti-Rao, Shobana
2010-01-01
Previous research has investigated the efficacy of peer-mediated repeated reading (RR) interventions carried out by student dyads. This research extends the existing research by investigating the impact of RR on oral reading fluency and comprehension when carried out by a teacher in small groups of fourth-grade students. Outcomes were analyzed…
PN-CCD camera for XMM: performance of high time resolution/bright source operating modes
NASA Astrophysics Data System (ADS)
Kendziorra, Eckhard; Bihler, Edgar; Grubmiller, Willy; Kretschmar, Baerbel; Kuster, Markus; Pflueger, Bernhard; Staubert, Ruediger; Braeuninger, Heinrich W.; Briel, Ulrich G.; Meidinger, Norbert; Pfeffermann, Elmar; Reppin, Claus; Stoetter, Diana; Strueder, Lothar; Holl, Peter; Kemmer, Josef; Soltau, Heike; von Zanthier, Christoph
1997-10-01
The pn-CCD camera is developed as one of the focal plane instruments for the European photon imaging camera (EPIC) on board the x-ray multi mirror (XMM) mission to be launched in 1999. The detector consists of four quadrants of three pn-CCDs each, which are integrated on one silicon wafer. Each CCD has 200 by 64 pixels (150 micrometer by 150 micrometers) with 280 micrometers depletion depth. One CCD of a quadrant is read out at a time, while the four quadrants can be processed independently of each other. In standard imaging mode the CCDs are read out sequentially every 70 ms. Observations of point sources brighter than 1 mCrab will be effected by photon pile- up. However, special operating modes can be used to observe bright sources up to 150 mCrab in timing mode with 30 microseconds time resolution and very bright sources up to several crab in burst mode with 7 microseconds time resolution. We have tested one quadrant of the EPIC pn-CCD camera at line energies from 0.52 keV to 17.4 keV at the long beam test facility Panter in the focus of the qualification mirror module for XMM. In order to test the time resolution of the system, a mechanical chopper was used to periodically modulate the beam intensity. Pulse periods down to 0.7 ms were generated. This paper describes the performance of the pn-CCD detector in timing and burst readout modes with special emphasis on energy and time resolution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.
We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The methodmore » consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.« less
Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.; ...
2015-01-27
We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The methodmore » consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.« less
An iPad-Based Tool for Improving the Skills of Children with Attention Deficit Disorder.
Wrońska, Natalia; Garcia-Zapirain, Begonya; Mendez-Zorrilla, Amaia
2015-06-02
Attention Deficit Hyperactivity Disorder (ADHD), with a worldwide prevalence of 5.29%-7.1%, is one of the most common neurodevelopmental disorders among children and adolescents. Apart from typical symptoms like inattention, hyperactivity and impulsiveness, patients also evidence attention deficit problems with reading comprehension. This in turn causes poor school performance and widens the gap with peers without ADHD. This paper presents a novel and interactive tool based on Serious Games for Health, whose aim is not only to improve comprehension, but also hold the user's attention. This tool is geared towards assessing reading quality and is intended for iPad devices. Preliminary results obtained from the experiment performed to evaluate the game are included in this report. A group of six typically developing children from Colegio Vizcaya aged between 8 and 12 took part in the evaluation of motivation, satisfaction and usability of the same therapy in the new media. Results obtained by participants playing the game were analysed together with questionnaires concerning the usability of the system. Game evaluation resulted in relatively good statistics-average score was 3 points out of 4 and average time for completing the exercise was 59 seconds. A SUS questionnaire with an average score of 92.75 out of 100 indicates that the game presented is user-friendly and an effective tool. Moreover, based on the feedback obtained from participants, the game had been improved and additional functionality introduced. Older participants completed the first game faster than the younger ones, but age was not influential in subsequent games.
An iPad-Based Tool for Improving the Skills of Children with Attention Deficit Disorder
Wrońska, Natalia; Garcia-Zapirain, Begonya; Mendez-Zorrilla, Amaia
2015-01-01
Attention Deficit Hyperactivity Disorder (ADHD), with a worldwide prevalence of 5.29%–7.1%, is one of the most common neurodevelopmental disorders among children and adolescents. Apart from typical symptoms like inattention, hyperactivity and impulsiveness, patients also evidence attention deficit problems with reading comprehension. This in turn causes poor school performance and widens the gap with peers without ADHD. This paper presents a novel and interactive tool based on Serious Games for Health, whose aim is not only to improve comprehension, but also hold the user’s attention. This tool is geared towards assessing reading quality and is intended for iPad devices. Preliminary results obtained from the experiment performed to evaluate the game are included in this report. A group of six typically developing children from Colegio Vizcaya aged between 8 and 12 took part in the evaluation of motivation, satisfaction and usability of the same therapy in the new media. Results obtained by participants playing the game were analysed together with questionnaires concerning the usability of the system. Game evaluation resulted in relatively good statistics-average score was 3 points out of 4 and average time for completing the exercise was 59 seconds. A SUS questionnaire with an average score of 92.75 out of 100 indicates that the game presented is user-friendly and an effective tool. Moreover, based on the feedback obtained from participants, the game had been improved and additional functionality introduced. Older participants completed the first game faster than the younger ones, but age was not influential in subsequent games. PMID:26042366
How well do final year undergraduate medical students master practical clinical skills?
Störmann, Sylvère; Stankiewicz, Melanie; Raes, Patricia; Berchtold, Christina; Kosanke, Yvonne; Illes, Gabrielle; Loose, Peter; Angstwurm, Matthias W.
2016-01-01
Introduction: The clinical examination and other practical clinical skills are fundamental to guide diagnosis and therapy. The teaching of such practical skills has gained significance through legislative changes and adjustments of the curricula of medical schools in Germany. We sought to find out how well final year undergraduate medical students master practical clinical skills. Methods: We conducted a formative 4-station objective structured clinical examination (OSCE) focused on practical clinical skills during the final year of undergraduate medical education. Participation was voluntary. Besides the examination of heart, lungs, abdomen, vascular system, lymphatic system as well as the neurological, endocrinological or orthopaedic examination we assessed other basic clinical skills (e.g. interpretation of an ECG, reading a chest X-ray). Participants filled-out a questionnaire prior to the exam, inter alia to give an estimate of their performance. Results: 214 final year students participated in our study and achieved a mean score of 72.8% of the total score obtainable. 9.3% of participants (n=20) scored insufficiently (<60%). We found no influence of sex, prior training in healthcare or place of study on performance. Only one third of the students correctly estimated their performance (35.3%), whereas 30.0% and 18.8% over-estimated their performance by 10% and 20% respectively. Discussion: Final year undergraduate medical students demonstrate considerable deficits performing practical clinical skills in the context of a formative assessment. Half of the students over-estimate their own performance. We recommend an institutionalised and frequent assessment of practical clinical skills during undergraduate medical education, especially in the final year. PMID:27579358
Workload Characterization of a Leadership Class Storage Cluster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Youngjae; Gunasekaran, Raghul; Shipman, Galen M
2010-01-01
Understanding workload characteristics is critical for optimizing and improving the performance of current systems and software, and architecting new storage systems based on observed workload patterns. In this paper, we characterize the scientific workloads of the world s fastest HPC (High Performance Computing) storage cluster, Spider, at the Oak Ridge Leadership Computing Facility (OLCF). Spider provides an aggregate bandwidth of over 240 GB/s with over 10 petabytes of RAID 6 formatted capacity. OLCFs flagship petascale simulation platform, Jaguar, and other large HPC clusters, in total over 250 thousands compute cores, depend on Spider for their I/O needs. We characterize themore » system utilization, the demands of reads and writes, idle time, and the distribution of read requests to write requests for the storage system observed over a period of 6 months. From this study we develop synthesized workloads and we show that the read and write I/O bandwidth usage as well as the inter-arrival time of requests can be modeled as a Pareto distribution.« less
Design and performance of a high spatial resolution, time-of-flight PET detector
Krishnamoorthy, Srilalan; LeGeyt, Benjamin; Werner, Matthew E.; Kaul, Madhuri; Newcomer, F. M.; Karp, Joel S.; Surti, Suleman
2014-01-01
This paper describes the design and performance of a high spatial resolution PET detector with time-of-flight capabilities. With an emphasis on high spatial resolution and sensitivity, we initially evaluated the performance of several 1.5 × 1.5 and 2.0 × 2.0 mm2 and 12–15 mm long LYSO crystals read out by several appropriately sized PMTs. Experiments to evaluate the impact of reflector on detector performance were performed and the final detector consisted of a 32 × 32 array of 1.5 × 1.5 × 15 mm3 LYSO crystals packed with a diffuse reflector and read out by a single Hamamatsu 64 channel multi-anode PMT. Such a design made it compact, modular and offered a cost-effective solution to obtaining excellent energy and timing resolution. To minimize the number of readout signals, a compact front-end readout electronics that summed anode signals along each of the orthogonal directions was also developed. Experimental evaluation of detector performance demonstrates clear discrimination of the crystals within the detector. An average energy resolution (FWHM) of 12.7 ± 2.6% and average coincidence timing resolution (FWHM) of 348 ps was measured, demonstrating suitability for use in the development of a high spatial resolution time-of-flight scanner for dedicated breast PET imaging. PMID:25246711
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirvonen, Liisa M.; Le Marois, Alix; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk
We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reducedmore » lifetime near the coverslip in TIR compared to epifluorescence FLIM.« less
The ability to tap to a beat relates to cognitive, linguistic, and perceptual skills
Tierney, Adam T.; Kraus, Nina
2013-01-01
Reading-impaired children have difficulty tapping to a beat. Here we tested whether this relationship between reading ability and synchronized tapping holds in typically-developing adolescents. We also hypothesized that tapping relates to two other abilities. First, since auditory-motor synchronization requires monitoring of the relationship between motor output and auditory input, we predicted that subjects better able to tap to the beat would perform better on attention tests. Second, since auditory-motor synchronization requires fine temporal precision within the auditory system for the extraction of a sound’s onset time, we predicted that subjects better able to tap to the beat would be less affected by backward masking, a measure of temporal precision within the auditory system. As predicted, tapping performance related to reading, attention, and backward masking. These results motivate future research investigating whether beat synchronization training can improve not only reading ability, but potentially executive function and basic auditory processing as well. PMID:23400117
NASA Astrophysics Data System (ADS)
Hoek, M.; Cardinali, M.; Corell, O.; Dickescheid, M.; Ferretti B., M. I.; Lauth, W.; Schlimme, B. S.; Sfienti, C.; Thiel, M.
2017-12-01
A prototype detector, called FLASH (Fast Light Acquiring Start Hodoscope), was built to provide precise Time-of-Flight (TOF) measurements and reference timestamps for detector setups at external beam lines. Radiator bars, made of synthetic fused silica, were coupled to a fast MCP-PMT with 64 channels and read out with custom electronics using Time-over-Threshold (TOT) for signal characterization. The TRB3 system, a high-precision TDC implemented in an FPGA, was used as data acquisition system. The performance of a system consisting of two FLASH units was investigated at a dedicated test experiment at the Mainz Microtron (MAMI) accelerator using its 855 MeV electron beam. The TOT measurement enabled time walk corrections and an overall TOF resolution of ∼70 ps could be achieved which translates into a resolution of ∼50 ps per FLASH unit. The intrinsic resolution of the frontend electronics including the TDC was measured to be less than 25 ps.
Producibility of Vertically Integrated Photodiode (VIP)tm scanning focal plane arrays
NASA Astrophysics Data System (ADS)
Turner, Arthur M.; Teherani, Towfik; Ehmke, John C.; Pettitt, Cindy; Conlon, Peggy; Beck, Jeffrey D.; McCormack, Kent; Colombo, Luigi; Lahutsky, Tom; Murphy, Terry; Williams, Robert L.
1994-07-01
Vertically integrated photodiode, VIPTM, technology is now being used to produce second generation infrared focal plane arrays with high yields and performance. The VIPTM process employs planar, ion implanted, n on p diodes in HgCdTe which is epoxy hybridized directly to the read out integrated circuits on 100 mm Si wafers. The process parameters that are critical for high performance and yield include: HgCdTe dislocation density and thickness, backside passivation, frontside passivation, and junction formation. Producibility of infrared focal plane arrays (IRFPAs) is also significantly enhanced by read out integrated circuits (ROICs) which have the ability to deselect defective pixels. Cold probe screening before lab dewar assembly reduces costs and improves cycle times. The 240 X 1 and 240 X 2 scanning array formats are used to demonstrate the effect of process optimization, deselect, and cold probe screening on yield and cycle time. The versatility of the VIPTM technology and its extension to large area arrays is demonstrated using 240/288 X 4 and 480 X 5 TDI formats. Finally, the high performance of VIPTM IRFPAs is demonstrated by comparing data from a 480 X 5 to the SADA-II specification.
Updated optical read/write memory system components
NASA Technical Reports Server (NTRS)
1974-01-01
A survey of the building blocks of the electro-optic read/write system was made. Critical areas and alternate paths are discussed. The latest PLZT block data composer is analyzed. Stricter controls in the production and fabrication of PLZT are implied by the performance of the BDC. A reverse charge before erase has eliminated several problems observed in the parallel plane charging process for photoconductor-thermoplastic hologram storage.
Design of a Low-Light-Level Image Sensor with On-Chip Sigma-Delta Analog-to- Digital Conversion
NASA Technical Reports Server (NTRS)
Mendis, Sunetra K.; Pain, Bedabrata; Nixon, Robert H.; Fossum, Eric R.
1993-01-01
The design and projected performance of a low-light-level active-pixel-sensor (APS) chip with semi-parallel analog-to-digital (A/D) conversion is presented. The individual elements have been fabricated and tested using MOSIS* 2 micrometer CMOS technology, although the integrated system has not yet been fabricated. The imager consists of a 128 x 128 array of active pixels at a 50 micrometer pitch. Each column of pixels shares a 10-bit A/D converter based on first-order oversampled sigma-delta (Sigma-Delta) modulation. The 10-bit outputs of each converter are multiplexed and read out through a single set of outputs. A semi-parallel architecture is chosen to achieve 30 frames/second operation even at low light levels. The sensor is designed for less than 12 e^- rms noise performance.
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, Jiangang; Blanche, Timothy J.; Harrison, Reid R.; Lester, Henry A.; Masmanidis, Sotiris C.
2011-01-01
Extracellular electrode arrays can reveal the neuronal network correlates of behavior with single-cell, single-spike, and sub-millisecond resolution. However, implantable electrodes are inherently invasive, and efforts to scale up the number and density of recording sites must compromise on device size in order to connect the electrodes. Here, we report on silicon-based neural probes employing nanofabricated, high-density electrical leads. Furthermore, we address the challenge of reading out multichannel data with an application-specific integrated circuit (ASIC) performing signal amplification, band-pass filtering, and multiplexing functions. We demonstrate high spatial resolution extracellular measurements with a fully integrated, low noise 64-channel system weighing just 330 mg. The on-chip multiplexers make possible recordings with substantially fewer external wires than the number of input channels. By combining nanofabricated probes with ASICs we have implemented a system for performing large-scale, high-density electrophysiology in small, freely behaving animals that is both minimally invasive and highly scalable. PMID:22022568
Selective Impairments in Covert Shifts of Attention in Chinese Dyslexic Children.
Ding, Yun; Zhao, Jing; He, Tao; Tan, Yufei; Zheng, Lingshuang; Wang, Zhiguo
2016-11-01
Reading depends heavily on the efficient shift of attention. Mounting evidence has suggested that dyslexics have deficits in covert attentional shift. However, it remains unclear whether dyslexics also have deficits in overt attentional shift. With the majority of relevant studies carried out in alphabetic writing systems, it is also unknown whether the attentional deficits observed in dyslexics are restricted to a particular writing system. The present study examined inhibition of return (IOR)-a major driving force of attentional shifts-in dyslexic children learning to read a logographic script (i.e., Chinese). Robust IOR effects were observed in both covert and overt attentional tasks in two groups of typically developing children, who were age- or reading ability-matched to the dyslexic children. In contrast, the dyslexic children showed IOR in the overt but not in the covert attentional task. We conclude that covert attentional shift is selectively impaired in dyslexic children. This impairment is not restricted to alphabetic writing systems, and it could be a significant contributor to the difficulties encountered by children learning to read. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Kelly, Dana; Nord, Christine Winquist; Jenkins, Frank; Chan, Jessica Ying; Kastberg, David
2013-01-01
The Program for International Student Assessment (PISA) is a system of international assessments that allows countries to compare outcomes of learning as students near the end of compulsory schooling. PISA core assessments measure the performance of 15-year-old students in mathematics, science, and reading literacy every 3 years. Coordinated by…
I/O performance evaluation of a Linux-based network-attached storage device
NASA Astrophysics Data System (ADS)
Sun, Zhaoyan; Dong, Yonggui; Wu, Jinglian; Jia, Huibo; Feng, Guanping
2002-09-01
In a Local Area Network (LAN), clients are permitted to access the files on high-density optical disks via a network server. But the quality of read service offered by the conventional server is not satisfied because of the multiple functions on the server and the overmuch caller. This paper develops a Linux-based Network-Attached Storage (NAS) server. The Operation System (OS), composed of an optimized kernel and a miniaturized file system, is stored in a flash memory. After initialization, the NAS device is connected into the LAN. The administrator and users could configure the access the server through the web page respectively. In order to enhance the quality of access, the management of buffer cache in file system is optimized. Some benchmark programs are peformed to evaluate the I/O performance of the NAS device. Since data recorded in optical disks are usually for reading accesses, our attention is focused on the reading throughput of the device. The experimental results indicate that the I/O performance of our NAS device is excellent.
X-ray Hybrid CMOS Detectors : Recent progress in development and characterization
NASA Astrophysics Data System (ADS)
Chattopadhyay, Tanmoy; Falcone, Abraham; Burrows, David N.
2017-08-01
PennState high energy astronomy laboratory has been working on the development and characterization of Hybrid CMOS Detectors (HCDs) for last few years in collaboration with Teledyne Imaging Sensors (TIS). HCDs are preferred over X-ray CCDs due to their higher and flexible read out rate, radiation hardness and low power which make them more suitable for next generation large area X-ray telescopic missions. An H2RG detector with 36 micron pixel pitch and 18 micron ROIC, has been selected for a sounding rocket flight in 2018. The H2RG detector provides ~2.5 % energy resolution at 5.9 keV and ~7 e- read noise when coupled to a cryo-SIDECAR. We could also detect a clear Oxygen line (~0.5 keV) from the detector implying a lower energy threshold of ~0.3 keV. Further improvement in the energy resolution and read noise is currently under progress. We have been working on the characterization of small pixel HCDs (12.5 micron pixel; smallest pixel HCDs developed so far) which is important for the development of next generation high resolution X-ray spectroscopic instrument based on HCDs. Event recognition in HCDs is another exciting prospect which have been successfully shown to work with a 64 X 64 pixel prototype SPEEDSTAR-EXD which use comparators at each pixel to read out only those pixels having detectable signal, thereby providing an order of magnitude improvement in the read out rate. Currently, we are working on the development of a large area SPEEDSTAR-EXD array for the development of a full fledged instrument. HCDs due to their fast read out, can also be explored as a large FOV instrument to study GRB afterglows and variability and spectroscopic study of other astrophysical transients. In this context, we are characterizing a Lobster-HCD system at multiple energies and multiple off-axis angles for future rocket or CubeSate experiments. In this presentation, I will briefly present these new developments and experiments with HCDs and the analysis techniques.
Techniques for Motivating Interest in Reading for the Disadvantaged High School Student
ERIC Educational Resources Information Center
Usova, George
1978-01-01
After explaining why disadvantaged youth have little interest in reading, this paper prescribes eight techniques to increase student interest in reading, including reading aloud with and to the students, acting out the reading material, using the newspaper, and advertising reading around the school. (RL)
ERIC Educational Resources Information Center
Rose, Dale Rennard
2017-01-01
The three article dissertation was a presentation of students' with learning disabilities perspectives on reading comprehension instruction. Article 1 set out to provide an historical perspective of reading and reading comprehension instruction. Topics covered in this research review included: reading comprehension, reading and learning…
Differing effects of two synthetic phonics programmes on early reading development.
Shapiro, Laura R; Solity, Jonathan
2016-06-01
Synthetic phonics is the widely accepted approach for teaching reading in English: Children are taught to sound out the letters in a word then blend these sounds together. We compared the impact of two synthetic phonics programmes on early reading. Children received Letters and Sounds (L&S; 7 schools) which teaches multiple letter-sound mappings or Early Reading Research (ERR; 10 schools) which teaches only the most consistent mappings plus frequent words by sight. We measured phonological awareness (PA) and reading from school entry to the end of the second (all schools) or third school year (4 ERR, 3 L&S schools). Phonological awareness was significantly related to all reading measures for the whole sample. However, there was a closer relationship between PA and exception word reading for children receiving the L&S programme. The programmes were equally effective overall, but their impact on reading significantly interacted with school-entry PA: Children with poor PA at school entry achieved higher reading attainments under ERR (significant group difference on exception word reading at the end of the first year), whereas children with good PA performed equally well under either programme. The more intensive phonics programme (L&S) heightened the association between PA and exception word reading. Although the programmes were equally effective for most children, results indicate potential benefits of ERR for children with poor PA. We suggest that phonics programmes could be simplified to teach only the most consistent mappings plus frequent words by sight. © 2015 The British Psychological Society.
Remote CT reading using an ultramobile PC and web-based remote viewing over a wireless network.
Choi, Hyuk Joong; Lee, Jeong Hun; Kang, Bo Seung
2012-01-01
We developed a new type of mobile teleradiology system using an ultramobile PC (UMPC) for web-based remote viewing over a wireless network. We assessed the diagnostic performance of this system for abdominal CT interpretation. Performance was compared with an emergency department clinical monitor using a DICOM viewer. A total of 100 abdominal CT examinations were presented to four observers. There were 56 examinations showing appendicitis and 44 which were normal. The observers viewed the images using a UMPC display and an LCD monitor and rated each examination on a five-point scale. Receiver operating characteristics (ROC) analysis was used to test for differences. The sensitivity and specificities of all observers were similarly high. The average area under the ROC curve for readings performed on the UMPC and the LCD monitor was 0.959 and 0.976, respectively. There were no significant differences between the two display systems for interpreting abdominal CTs. The web-based mobile teleradiology system appears to be feasible for reading abdominal CTs for diagnosing appendicitis and may be valuable in emergency teleconsultation. Copyright © 2012 by the Royal Society of Medicine Press Ltd
1988-12-01
interval of four feet, and are numbered sequentially bow to stem. * "wing tank" is a tank or void, outboard of the holding bulkhead, away from the center...system and DBMS simultaneously with a multi-processor, allowing queries to the DBMS without terminating the expert system. This method was judged...RECIRC). eductor -strip("Y"):- ask _ques _read_ans(OVBD,"ovbd dis open"),ovbd dis-open(OVBD). eductor-strip("N"):- ask_ques read_ans( LINEUP , "strip lineup
Neily, Julia; Chomsky, Amy; Orcutt, James; Paull, Douglas E; Mills, Peter D; Gilbert, Christina; Hemphill, Robin R; Gunnar, William
2018-03-01
The study goals were to examine wrong intraocular lens (IOL) implant adverse events in the Veterans Health Administration (VHA), identify root causes and contributing factors, and describe system changes that have been implemented to address this challenge. This study represents collaboration between the VHA's National Center for Patient Safety (NCPS) and the National Surgery Office (NSO). This report includes 45 wrong IOL implant surgery adverse events reported to established VHA NCPS and NSO databases between July 1, 2006, and June 31, 2014. There are approximately 50,000 eye implant procedures performed each year in the VHA. Wrong IOL implant surgery adverse events are reported by VHA facilities to the NCPS and the NSO. Two authors (A.C. and J.N.) coded the reports for event type (wrong lens or expired lens) and identified the primary contributing factor (coefficient κ = 0.837). A descriptive analysis was conducted, which included the reported yearly event rate. The main outcome measure was the reported wrong IOL implant surgery adverse events. There were 45 reported wrong IOL implant surgery adverse events. Between 2011 and June 30, 2014, there was a significant downward trend (P = 0.02, R = 99.7%) at a pace of -0.08 (per 10,000 cases) every year. The most frequently coded primary contributing factor was incomplete preprocedure time-out (n = 12) followed by failure to perform double check of preprocedural calculations based upon original data and implant read-back at the time the surgical eye implant was performed (n = 10). Preventing wrong IOL implant adverse events requires diligence beyond performance of the preprocedural time-out. In 2013, the VHA has modified policy to ensure double check of preprocedural calculations and implant read-back with positive impact. Continued analysis of contributing human factors and improved surgical team communication are warranted.
High resolution upgrade of the ATF damping ring BPM system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terunuma, N.; Urakawa, J.; /KEK, Tsukuba
2008-05-01
A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished in its first stage, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital downconversion techniques, digital signal processing, and also tests a new automatic gain error correction schema. The technical concept and realization, as well as preliminary results of beam studies are presented.
Students' performance in phonological awareness, rapid naming, reading, and writing.
Capellini, Simone Aparecida; Lanza, Simone Cristina
2010-01-01
phonological awareness, rapid naming, reading and writing in students with learning difficulties of a municipal public school. to characterize and compare the performance of students from public schools with and without learning difficulties in phonological awareness, rapid naming, reading and writing. participants were 60 students from the 2nd to the 4th grades of municipal public schools divided into 6 groups. Each group was composed by 10 students, being 3 groups of students without learning difficulties and 3 groups with students with learning difficulties. As testing procedure phonological awareness, rapid automatized naming, oral reading and writing under dictation assessments were used. the results highlighted the better performance of students with no learning difficulties. Students with learning difficulties presented a higher ratios considering time/speed in rapid naming tasks and, consequently, lower production in activities of phonological awareness and reading and writing, when compared to students without learning difficulties. students with learning difficulties presented deficits when considering the relationship between naming and automatization skills, and among lexical access, visual discrimination, stimulus frequency use and competition in using less time for code naming, i.e. necessary for the phoneme-grapheme conversion process required in the reading and writing alphabetic system like the Portuguese language.
NASA Astrophysics Data System (ADS)
Dutt, R. N.; Meena, D. K.; Kar, S.; Soni, V.; Nadaf, A.; Das, A.; Singh, F.; Datta, T. S.
2017-02-01
A system for carrying out automatic experimental measurements of various electrical transport characteristics and their relation to magnetic fields for samples mounted on the sample holder on a Variable Temperature Insert (VTI) of the Cryogen Free Superconducting Magnet System (CFMS) has been developed. The control and characterization system is capable of monitoring, online plotting and history logging in real-time of cryogenic temperatures with the Silicon (Si) Diode and Zirconium Oxy-Nitride sensors installed inside the magnet facility. Electrical transport property measurements have been automated with implementation of current reversal resistance measurements and automatic temperature set-point ramping with the parameters of interest available in real-time as well as for later analysis. The Graphical User Interface (GUI) based system is user friendly to facilitate operations. An ingenious electronics for reading Zirconium Oxy-Nitride temperature sensors has been used. Price to performance ratio has been optimized by using in house developed measurement techniques mixed with specialized commercial cryogenic measurement / control equipment.
High-precision ground-based photometry of exoplanets
NASA Astrophysics Data System (ADS)
de Mooij, Ernst J. W.; Jayawardhana, Ray
2013-04-01
High-precision photometry of transiting exoplanet systems has contributed significantly to our understanding of the properties of their atmospheres. The best targets are the bright exoplanet systems, for which the high number of photons allow very high signal-to-noise ratios. Most of the current instruments are not optimised for these high-precision measurements, either they have a large read-out overhead to reduce the readnoise and/or their field-of-view is limited, preventing simultaneous observations of both the target and a reference star. Recently we have proposed a new wide-field imager for the Observatoir de Mont-Megantic optimised for these bright systems (PI: Jayawardhana). The instruments has a dual beam design and a field-of-view of 17' by 17'. The cameras have a read-out time of 2 seconds, significantly reducing read-out overheads. Over the past years we have obtained significant experience with how to reach the high precision required for the characterisation of exoplanet atmospheres. Based on our experience we provide the following advice:
NASA Astrophysics Data System (ADS)
Bianco, M.; Martoiu, S.; Sidiropoulou, O.; Zibell, A.
2015-12-01
A Micromegas (MM) quadruplet prototype with an active area of 0.5 m2 that adopts the general design foreseen for the upgrade of the innermost forward muon tracking systems (Small Wheels) of the ATLAS detector in 2018-2019, has been built at CERN and is going to be tested in the ATLAS cavern environment during the LHC RUN-II period 2015-2017. The integration of this prototype detector into the ATLAS data acquisition system using custom ATCA equipment is presented. An ATLAS compatible Read Out Driver (ROD) based on the Scalable Readout System (SRS), the Scalable Readout Unit (SRU), will be used in order to transmit the data after generating valid event fragments to the high-level Read Out System (ROS). The SRU will be synchronized with the LHC bunch crossing clock (40.08 MHz) and will receive the Level-1 trigger signals from the Central Trigger Processor (CTP) through the TTCrx receiver ASIC. The configuration of the system will be driven directly from the ATLAS Run Control System. By using the ATLAS TDAQ Software, a dedicated Micromegas segment has been implemented, in order to include the detector inside the main ATLAS DAQ partition. A full set of tests, on the hardware and software aspects, is presented.
Cognitive Style and Reading Comprehension in L1 and L2.
ERIC Educational Resources Information Center
Vivaldo-Lima, Javier
This paper presents the results of a research study carried out with Mexican college students to analyze the relationship between readers' cognitive styles (field dependent/independent) and their performance at different levels of written discourse processing in Spanish (L1) and English (L2). The sample for the study included 452 undergraduate…
Lin, Chao; Shen, Xueju; Li, Baochen
2014-08-25
We demonstrate that all parameters of optical lightwave can be simultaneously designed as keys in security system. This multi-dimensional property of key can significantly enlarge the key space and further enhance the security level of the system. The single-shot off-axis digital holography with orthogonal polarized reference waves is employed to perform polarization state recording on object wave. Two pieces of polarization holograms are calculated and fabricated to be arranged in reference arms to generate random amplitude and phase distribution respectively. When reconstruction, original information which is represented with QR code can be retrieved using Fresnel diffraction with decryption keys and read out noise-free. Numerical simulation results for this cryptosystem are presented. An analysis on the key sensitivity and fault tolerance properties are also provided.
Studies of beam position monitor stability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tenenbaum, P.
1998-05-01
The authors present the results from two studies of the time stability between the mechanical center of a beam position monitor and its electrical/electronic center. In the first study, a group of 93 BPM processors was calibrated via Test Pulse Generator once per hour in order to measure the contribution of the readout electronics to offset drifts. In the second study, a triplet of stripline BPMs in the Final Focus Test Beam, separated only by drift spaces, was read out every 6 minutes during 1 week of beam operation. In both cases offset stability was observed to be on themore » order of microns over time spans ranging from hours to days, although during the beam study much worse performance was also observed. Implications for the beam position monitor system of future linear collider systems are discussed.« less
In-beam PET data characterization with the large area DoPET prototype
NASA Astrophysics Data System (ADS)
Sportelli, G.; Belcari, N.; Camarlinghi, N.; Ciocca, M.; Collini, F.; Molinelli, S.; Pullia, M.; Zaccaro, E.; Del Guerra, A.; Rosso, V.
2016-02-01
Range verification with in-beam PET techniques is a powerful tool for monitoring the correctness of dose delivery in particle therapy. Among the major limitations of in-beam PET systems are the limited detectors size due to the constrained space in which they can be placed to allow the irradiation, and the necessity of a high read-out modularization, due to high activity rates during the irradiation. In this work we present the data acquired at the CNAO (Centro Nazionale di Adroterapia Oncologica) treatment center in Pavia, Italy, with the new DoPET system, specifically designed to operate in in-beam conditions. The new prototype consists of two planar 15cm × 15cm LYSO-based detectors, read out by 9 PMT detector modules each. In particular, we test the capability of our system to determine particle range in various irradiation conditions. Several plastic phantoms were irradiated at the CNAO treatment centre with protons and carbon ions of various energies. The used dose in treatment plans is 2 Gy and the monitoring feedback is produced in a few minutes after the end of the treatment.
High Resolution Imaging with MUSTANG-2 on the GBT
NASA Astrophysics Data System (ADS)
Stanchfield, Sara; Ade, Peter; Aguirre, James; Brevik, Justus A.; Cho, Hsiao-Mei; Datta, Rahul; Devlin, Mark; Dicker, Simon R.; Dober, Bradley; Duff, Shannon M.; Egan, Dennis; Ford, Pam; Hilton, Gene; Hubmayr, Johannes; Irwin, Kent; Knowles, Kenda; Marganian, Paul; Mason, Brian Scott; Mates, John A. B.; McMahon, Jeff; Mello, Melinda; Mroczkowski, Tony; Romero, Charles; Sievers, Jonathon; Tucker, Carole; Vale, Leila R.; Vissers, Michael; White, Steven; Whitehead, Mark; Ullom, Joel; Young, Alexander
2018-01-01
We present early science results from MUSTANG-2, a 90 GHz feedhorn-coupled, microwave SQUID-multiplexed TES bolometer array operating on the Robert C. Byrd Green Bank Telescope (GBT). The feedhorn and waveguide-probe-coupled detector technology is a mature technology, which has been used on instruments such as the South Pole Telescope, the Atacama Cosmology Telescope, and the Atacama B-mode Search telescope. The microwave SQUID multiplexer-based readout system developed for MUSTANG-2 currently reads out 66 detectors with a single coaxial cable and will eventually allow thousands of detectors to be multiplexed. This microwave SQUID multiplexer combines the proven abilities of millimeter wave TES detectors with the multiplexing capabilities of KIDs with no degradation in noise performance of the detectors. Each multiplexing device is read out using warm electronics consisting of a commercially available ROACH board, a DAC/ADC card, and an Intermediate Frequency mixer circuit. The hardware was originally developed by the Collaboration for Astronomy Signal Processing and Electronic Research (CASPER) group, whose primary goal is to develop scalable FPGA-based hardware with the flexibility to be used in a wide range of radio signal processing applications. MUSTANG-2 is the first on-sky instrument to use microwave SQUID multiplexing and is available as a shared-risk/PI instrument on the GBT. In MUSTANG-2’s first season 7 separate proposals were awarded a total of 230 hours of telescope time.
NASA Astrophysics Data System (ADS)
Guns, Christine
Guided reading, as developed by Fountas and Pinnell (2001), has been a staple of elementary reading programs for the past decade. Teachers in the elementary school setting utilize this small group, tailored instruction in order to differentiate and meet the instructional needs of the students. The literature shows academic benefit for students who have special needs, such as learning disabilities, autism, and hearing impairments but consideration of academic impact has not been investigated for regular education students. The purpose of this quasi-experimental study was to investigate the academic impact of the use of content-related (Group C) and the traditional literature-based (Group L) reading materials. During the Living Systems and Life Processes unit in science, two teachers self-selected to utilized science-related materials for guided reading instruction while the other three teacher participants utilized their normal literature-based guided reading materials. The two groups were compared using an ANCOVA in this pre-test/post-test design. The dependent variables included the Reading for Application and Instruction assessment (RAI) and a Living Systems and Life Processes assessment (LSA). Further analysis compared students of different reading levels and gender. The data analyses revealed a practical but not statistical significance for students in science performance. It was discovered that below level male and female students performed better on the LSA when provided with content-related guided reading materials. As far as reading achievement is concerned, students in both groups had comparable results. The teachers provided guided reading instruction to their students with fidelity and made adjustments to their practices due to the needs of their students. The content-related teachers utilized a larger number of expository texts than the literature-based teachers. These teachers expressed the desire to continue the practice of providing the students with content-related materials.
The Journey toward Literacy Begins in Infancy: The Reach out and Read Innovation
ERIC Educational Resources Information Center
Fahey, Jean Ciborowski; Forman, Judith
2012-01-01
Reach Out and Read is an evidence-based nonprofit organization that promotes early literacy and school readiness in pediatric exam rooms throughout the United States by giving new books to children and advice to parents about the importance of reading aloud. The program began in 1989 at what was then called Boston City Hospital, and is now known…
Swanson, H L; Trahan, M
1996-09-01
The present study investigates (a) whether learning disabled readers' working memory deficits that underlie poor reading comprehension are related to a general system, and (b) whether metacognition contributes to comprehension beyond what is predicted by working memory and word knowledge. To this end, performance between learning and disabled (N = 60) and average readers (N = 60) was compared on the reading comprehension, reading rate, and vocabulary subtests of the Nelson Skills Reading Test, Sentence Span test composed of high and low imagery words, and a Metacognitive Questionnaire. As expected, differences between groups in working memory, vocabulary, and reading measures emerged, whereas ability groups were statistically comparable on the Metacognitive Questionnaire. A within-group analysis indicated that the correlation patterns between working memory, vocabulary, metacognition, and reading comprehension were not the same between ability groups. For predicting reading comprehension, the metacognitive questionnaire best predicted learning disabled readers' performance, whereas the working memory span measure that included low-imagery words best predicted average achieving readers' comprehension. Overall, the results suggest that the relationship between learning disabled readers' generalised working memory deficits and poor reading comprehension may be mediated by metacognition.
Reading Activities of American Adults.
ERIC Educational Resources Information Center
Sharon, Amiel T.
A reading activities survey as part of the Targeted Research and Development Reading Program was done by interviewing 3,504 adults, aged 16 years or older, selected by area probability sampling. Among the preliminary findings was that the most frequent type of reading is newspaper reading. Seven out of 10 people read or look at a newspaper during…
ERIC Educational Resources Information Center
Nation, Paul
2009-01-01
This article describes the visual nature of the reading process as it relates to reading speed. It points out that there is a physical limit on normal reading speed and beyond this limit the reading process will be different from normal reading where almost every word is attended to. The article describes a range of activities for developing…
Lorusso, Maria Luisa; Civati, Federica; Molteni, Massimo; Turconi, Anna Carla; Bresolin, Nereo; D'Angelo, Maria Grazia
2013-01-01
A group of 42 Italian boys with Duchenne Muscular Dystrophy was compared with a control group of 10 boys with Spinal Muscular Atrophy and Osteogenesis Imperfecta on tests assessing general intellectual ability, language, neuropsychological functions, and reading skills with the aim of describing a comprehensive profile of the various functions and investigating their interrelationships. The influence of general intellectual level on performance was analyzed. Further, correlations between various neuropsychological measures and language performances were computed for the group with Duchenne Muscular Dystrophy, as well as the correlations between reading scores and other cognitive and linguistic measures. A general lowering in VIQ, PIQ, and FSIQ scores was found to characterize the group with Duchenne Muscular Dystrophy. Expressive language skills were within the normal range, while syntactic and grammatical comprehension were significantly impaired. The presence of below-average reading performances was further confirmed. However, unlike previous studies on irregular orthographies, the present results show that (a) the mild reading difficulties found in the sample essentially concern speed rather than accuracy; (b) they concern word rather than nonword reading; (c) lower reading performances are related to lower scores in general IQ; (d) no correlations emerge with phonological abilities, verbal short-term memory, or working memory, but rather with long-term memory and lexical skills. This may suggest that language-specific effects modulate the cognitive expressions of Duchenne Muscular Dystrophy and raises the possibility that the dysfunctions underlying the reading difficulties observed in affected readers of regular orthographies involve different neurocognitive systems than the cortico-cerebellar circuits usually invoked.
NASA Technical Reports Server (NTRS)
Bogomolov, E. A.; Yevstafev, Y. Y.; Karakadko, V. K.; Lubyanaya, N. D.; Romanov, V. A.; Totubalina, M. G.; Yamshchikov, M. A.
1975-01-01
A system for the recording and processing of telescope data is considered for measurements of EW asymmetry. The information is recorded by 45 channels on a continuously moving 35-mm film. The dead time of the recorder is about 0.1 sec. A sorting electronic circuit is used to reduce the errors when the statistical time distribution of the pulses is recorded. The recorded information is read out by means of photoresistors. The phototransmitter signals are fed either to the mechanical recorder unit for preliminary processing, or to a logical circuit which controls the operation of the punching device. The punched tape is processed by an electronic computer.
Tsapkini, Kyrana; Vindiola, Manuel; Rapp, Brenda
2011-04-01
Little is known about the neural reorganization that takes place subsequent to lesions that affect orthographic processing (reading and/or spelling). We report on an fMRI investigation of an individual with a left mid-fusiform resection that affected both reading and spelling (Tsapkini & Rapp, 2010). To investigate possible patterns of functional reorganization, we compared the behavioral and neural activation patterns of this individual with those of a group of control participants for the tasks of silent reading of words and pseudowords and the passive viewing of faces and objects, all tasks that typically recruit the inferior temporal lobes. This comparison was carried out with methods that included a novel application of Mahalanobis distance statistics, and revealed: (1) normal behavioral and neural responses for face and object processing, (2) evidence of neural reorganization bilaterally in the posterior fusiform that supported normal performance in pseudoword reading and which contributed to word reading (3) evidence of abnormal recruitment of the bilateral anterior temporal lobes indicating compensatory (albeit insufficient) recruitment of mechanisms for circumventing the word reading deficit. Copyright © 2010 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, Christopher J; Ahrens, James P; Wang, Jun
2010-10-15
Petascale simulations compute at resolutions ranging into billions of cells and write terabytes of data for visualization and analysis. Interactive visuaUzation of this time series is a desired step before starting a new run. The I/O subsystem and associated network often are a significant impediment to interactive visualization of time-varying data; as they are not configured or provisioned to provide necessary I/O read rates. In this paper, we propose a new I/O library for visualization applications: VisIO. Visualization applications commonly use N-to-N reads within their parallel enabled readers which provides an incentive for a shared-nothing approach to I/O, similar tomore » other data-intensive approaches such as Hadoop. However, unlike other data-intensive applications, visualization requires: (1) interactive performance for large data volumes, (2) compatibility with MPI and POSIX file system semantics for compatibility with existing infrastructure, and (3) use of existing file formats and their stipulated data partitioning rules. VisIO, provides a mechanism for using a non-POSIX distributed file system to provide linear scaling of 110 bandwidth. In addition, we introduce a novel scheduling algorithm that helps to co-locate visualization processes on nodes with the requested data. Testing using VisIO integrated into Para View was conducted using the Hadoop Distributed File System (HDFS) on TACC's Longhorn cluster. A representative dataset, VPIC, across 128 nodes showed a 64.4% read performance improvement compared to the provided Lustre installation. Also tested, was a dataset representing a global ocean salinity simulation that showed a 51.4% improvement in read performance over Lustre when using our VisIO system. VisIO, provides powerful high-performance I/O services to visualization applications, allowing for interactive performance with ultra-scale, time-series data.« less
Development of radiation tolerant monolithic active pixel sensors with fast column parallel read-out
NASA Astrophysics Data System (ADS)
Koziel, M.; Dorokhov, A.; Fontaine, J.-C.; De Masi, R.; Winter, M.
2010-12-01
Monolithic active pixel sensors (MAPS) [1] (Turchetta et al., 2001) are being developed at IPHC—Strasbourg to equip the EUDET telescope [2] (Haas, 2006) and vertex detectors for future high energy physics experiments, including the STAR upgrade at RHIC [3] (T.S. Collaboration, 2005) and the CBM experiment at FAIR/GSI [4] (Heuser, 2006). High granularity, low material budget and high read-out speed are systematically required for most applications, complemented, for some of them, with high radiation tolerance. A specific column-parallel architecture, implemented in the MIMOSA-22 sensor, was developed to achieve fast read-out MAPS. Previous studies of the front-end architecture integrated in this sensor, which includes in-pixel amplification, have shown that the fixed pattern noise increase consecutive to ionizing radiation can be controlled by means of a negative feedback [5] (Hu-Guo et al., 2008). However, an unexpected rise of the temporal noise was observed. A second version of this chip (MIMOSA-22bis) was produced in order to search for possible improvements of the radiation tolerance, regarding this type of noise. In this prototype, the feedback transistor was tuned in order to mitigate the sensitivity of the pixel to ionizing radiation. The performances of the pixels after irradiation were investigated for two types of feedback transistors: enclosed layout transistor (ELT) [6] (Snoeys et al., 2000) and "standard" transistor with either large or small transconductance. The noise performance of all test structures was studied in various conditions (expected in future experiments) regarding temperature, integration time and ionizing radiation dose. Test results are presented in this paper. Based on these observations, ideas for further improvement of the radiation tolerance of column parallel MAPS are derived.
Diehl, V A; Mills, C B
1995-11-01
In two experiments, subjects interacted to different extents with relevant devices while reading two complex multistep procedural texts and were then tested with task performance time, true/false, and recall measures. While reading, subjects performed the task (read and do), saw the experimenter perform the task (read and see experimenter do), imagined doing the task (read and imagine), looked at the device while reading (read and see), or only read (read only). Van Dijk and Kintsch's (1983) text representation theory led to the prediction that exposure to the task device (in the read-and-do, read-and-see, and read-and-see-experimenter-do conditions) would lead to the development of a stronger situation model and therefore faster task performance, whereas the read-only and read-and-see conditions would lead to a better textbase, and therefore better performance on the true/false and recall tasks. Paivio's (1991) dual coding theory led to the opposite prediction for recall. The results supported the text representation theory with task performance and recall. The read-and-see condition produced consistently good performance on the true/false measure. Amount of text study time contributed to recall performance. These findings support the notion that information available while reading leads to differential development of representations in memory, which, in turn, causes differences in performance on various measures.
The Process of the Development of an Operator
NASA Technical Reports Server (NTRS)
Banks, Terrence
2010-01-01
On the job training is where new employees called operators can start gaining knowledge on what they will be working on during their time in JSC. In these lessons I learned different things that are important ranging from thermal systems to electrical systems. While doing OJT classes the student will learn how to use a portable computer system which has displays that I also helped edit and clean up. The way you can also learn is by reading system briefs which describes the different systems. Due to the fact of a possible change in the ISS I updated a systems brief so that it can be relevant to what is actually on the space station. I was given a task that will help develop my skills and make myself better prepared for my future in the work field. The project that I worked on had me pulling real time data from the International Space Station. The Data I obtained from the space station will be correlated to battery performance. The group I will be working which is called REBA and we will take the telemetry and evaluate the data. I will be working with my mentor Ben Chislom and co-op Tyler along with the Pro team. They then will put this data into a graph so that they can get the discrepancies and find a way to improve the battery performance. The first weeks I read familiarization books that informed me how the ISS works, how it was built, and the systems that are used to keep the station working. This project is going to benefit NASA by finding out how electricity is being used on the ISS and enabling us to see how it can be used more efficiently. This way we can operate the ISS without wasting power. While conducting research that goes on inside the space station knowing all electricity is being used efficiently.
Reading and visual processing in Greek dyslexic children: an eye-movement study.
Hatzidaki, Anna; Gianneli, Maria; Petrakis, Eftichis; Makaronas, Nikolaos; Aslanides, Ioannis M
2011-02-01
We examined the impact of the effects of dyslexia on various processing and cognitive components (e.g., reading speed and accuracy) in a language with high phonological and orthographic consistency. Greek dyslexic children were compared with a chronological age-matched group on tasks that tested participants' phonological and orthographic awareness during reading and spelling, as well as their efficiency to detect a specific target-letter during a sequential visual search task. Dyslexic children showed impaired reading and spelling that was reflected in slow reading speed and error-prone performance, especially for non-words. Eye movement measures of text reading also provided supporting evidence for a reading deficit, with dyslexic participants producing more fixations and longer fixation duration as opposed to non-dyslexic participants. The results of the visual search task showed similar performance between the two groups, but when they were compared with the results of text reading, dyslexic participants were found to be able to process fewer stimuli (i.e., letters) at each fixation than non-dyslexics. Our findings further suggest that, although Greek dyslexics have the advantage of a consistent orthographic system which facilitates acquisition of reading and phonological awareness, they demonstrate more impaired access to orthographic forms than dyslexics of other transparent orthographies. Copyright © 2010 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Heslin, J. Alexander, Jr.
In senior-level undergraduate research courses in Computer Information Systems (CIS), students are required to read and assimilate a large volume of current research literature. One course objective is to demonstrate to the student that there are patterns or models or paradigms of research. A new approach in identifying research paradigms is…
ERIC Educational Resources Information Center
Lancioni, Giulio E.; O'Reilly, Mark F.; Singh, Nirbhay N.; Sigafoos, Jeff; Green, Vanessa A.; Oliva, Doretta; Alberti, Gloria; Carrella, Luigina
2013-01-01
This study extended the research on a special text messaging system, which allows persons with multiple disabilities to (a) write and send messages to distant partners and (b) have messages from those partners read out to them. The study involved two women with multiple disabilities (including blindness or minimal residual vision). The system…
Reprint Filing: A Profile-Based Solution
Gass, David A.; Putnam, R. Wayne
1983-01-01
A reprint filing system based on practice profiles can give family physicians easy access to relevant medical information. The use of the ICHPPC classification and some supplemental categories provides a more practical coding mechanism than organ systems, textbook chapter titles or even Index Medicus subject headings. The system can be simply maintained, updated and improved, but users must regularly weed out unused information, and read widely to keep the reprints current. PMID:21283301
Wolff, Ulrika
2014-07-01
Although phonemic awareness is a well-known factor predicting early reading development, there is also evidence that Rapid Automatized Naming (RAN) is an independent factor that contributes to early reading. The aim of this study is to examine phonemic awareness and RAN as predictors of reading speed, reading comprehension and spelling for children with reading difficulties. It also investigates a possible reciprocal relationship between RAN and reading skills, and the possibility of enhancing RAN by intervention. These issues are addressed by examining longitudinal data from a randomised reading intervention study carried out in Sweden for 9-year-old children with reading difficulties (N = 112). The intervention comprised three main elements: training of phonics, reading comprehension strategies and reading speed. The analysis of the data was carried out using structural equation modelling. The results demonstrated that after controlling for autoregressive effects and non-verbal IQ, RAN predicts reading speed whereas phonemic awareness predicts reading comprehension and spelling. RAN was significantly enhanced by training and a reciprocal relationship between reading speed and RAN was found. These findings contribute to support the view that both phonemic awareness and RAN independently influence early phases of reading, and that both are possible to enhance by training.
Inexpensive Neutron Imaging Cameras Using CCDs for Astronomy
NASA Astrophysics Data System (ADS)
Hewat, A. W.
We have developed inexpensive neutron imaging cameras using CCDs originally designed for amateur astronomical observation. The low-light, high resolution requirements of such CCDs are similar to those for neutron imaging, except that noise as well as cost is reduced by using slower read-out electronics. For example, we use the same 2048x2048 pixel ;Kodak; KAI-4022 CCD as used in the high performance PCO-2000 CCD camera, but our electronics requires ∼5 sec for full-frame read-out, ten times slower than the PCO-2000. Since neutron exposures also require several seconds, this is not seen as a serious disadvantage for many applications. If higher frame rates are needed, the CCD unit on our camera can be easily swapped for a faster readout detector with similar chip size and resolution, such as the PCO-2000 or the sCMOS PCO.edge 4.2.
A Study of Students' Reading Interests in a Second Language
ERIC Educational Resources Information Center
Khairuddin, Zurina
2013-01-01
Reading interests is important in enhancing students' success in school and out of it. Hence, students need to have high reading interests. The purpose of this study was to identify students' reading interests in reading second language materials and to examine the differences in students' reading interests based on genders. This study was carried…
Exploring Intrinsic and Extrinsic Reading Motivation among Very Good and Very Poor Readers
ERIC Educational Resources Information Center
McGeown, Sarah P.; Norgate, Roger; Warhurst, Amy
2012-01-01
Background: Research examining the relationship between reading skill and reading motivation has typically been carried out among children with a wide range of reading abilities. There is less research focusing on children who excel in reading or who are attaining very low reading scores. Purpose: To examine whether there were differences between…
The Politics of the Teaching of Reading
ERIC Educational Resources Information Center
Soler, Janet
2016-01-01
Historically, political debates have broken out over how to teach reading in primary schools and infant classrooms. These debates and "reading wars" have often resulted from public concerns and media reportage of a fall in reading standards. They also reflect the importance placed on learning to read by parents, teachers, employers, and…
Teacher Modeling: Its Impact on an Extensive Reading Program
ERIC Educational Resources Information Center
Loh, Jason Kok Khiang
2009-01-01
This case study investigates whether teachers model reading in 1 Singapore primary school during an exercise called "uninterrupted sustained silent reading" (USSR) carried out in the classroom. Even though reading is an important determinant of a student's growth in language skills and ability, and modeling the act of reading is…
NASA Astrophysics Data System (ADS)
Hu, Kun; Lu, Houbing; Wang, Xu; Li, Feng; Wang, Xinxin; Geng, Tianru; Yang, Hang; Liu, Shengquan; Han, Liang; Jin, Ge
2017-06-01
A front-end electronics prototype for the ATLAS small-strip Thin Gap Chamber (sTGC) based on gigabit Ethernet has been developed. The prototype is designed to read out signals of pads, wires, and strips of the sTGC detector. The prototype includes two VMM2 chips developed to read out the signals of the sTGC, a Xilinx Kintex-7 field-programmable gate array (FPGA) used for the VMM2 configuration and the events storage, and a gigabit Ethernet transceiver PHY chip for interfacing with a computer. The VMM2 chip is designed for the readout of the Micromegas detector and sTGC detector, which is composed of 64 linear front-end channels. Each channel integrates a charge-sensitive amplifier, a shaper, several analog-to-digital converters, and other digital functions. For a bunch-crossing interval of 25 ns, events are continuously read out by the FPGA and forwarded to the computer. The interface between the computer and the prototype has been measured to reach an error-free rate of 900 Mb/s, therefore making a very effective use of the available bandwidth. Additionally, the computer can control several prototypes of this kind simultaneously via the Ethernet interface. At present, the prototype will be used for the sTGC performance test. The features of the prototype are described in detail.
Predicting Reading and Spelling Disorders: A 4-Year Prospective Cohort Study.
Bigozzi, Lucia; Tarchi, Christian; Caudek, Corrado; Pinto, Giuliana
2016-01-01
In this 4-year prospective cohort study, children with a reading and spelling disorder, children with a spelling impairment, and children without a reading and/or spelling disorder (control group) in a transparent orthography were identified in third grade, and their emergent literacy performances in kindergarten compared retrospectively. Six hundred and forty-two Italian children participated. This cohort was followed from the last year of kindergarten to third grade. In kindergarten, the children were assessed in phonological awareness, conceptual knowledge of writing systems and textual competence. In third grade, 18 children with a reading and spelling impairment and 13 children with a spelling impairment were identified. Overall, conceptual knowledge of the writing system was the only statistically significant predictor of the clinical samples. No differences were found between the two clinical samples.
Proactive Byzantine Quorum Systems
NASA Astrophysics Data System (ADS)
Alchieri, Eduardo A. P.; Bessani, Alysson Neves; Pereira, Fernando Carlos; da Silva Fraga, Joni
Byzantine Quorum Systems is a replication technique used to ensure availability and consistency of replicates data even in presence of arbitrary faults. This paper presents a Byzantine Quorum Systems protocol that provides atomic semantics despite the existence of Byzantine clients and servers. Moreover, this protocol is integrated with a protocol for proactive recovery of servers. In that way, the system tolerates any number of failures during its lifetime, since no more than f out of n servers fail during a small interval of time between recoveries. All solutions proposed in this paper can be used on asynchronous systems, which requires no time assumptions. The proposed quorum system read and write protocols have been implemented and their efficiency is demonstrated through some experiments carried out in the Emulab platform.
ERIC Educational Resources Information Center
Manzo, Ula; Manzo, Anthony V.
2013-01-01
In this article, we discuss the Informal Reading-"Thinking" Inventory (IR-TI), an informal reading inventory built on an easily recognized legacy model that also branches out into new realms. The IR-TI provides tools for assessing reading the lines, reading between the lines, and reading beyond the lines. This is a 21st-century…
ERIC Educational Resources Information Center
Huang, Yueh-Min; Liang, Tsung-Ho
2015-01-01
Tracking individual reading behaviors is a difficult task, as is carrying out real-time recording and analysis throughout the reading process, but these aims are worth pursuing. In this study, the reading rate is adopted as an indicator to identify different reading behaviors and comprehension outcomes. A reading rate tracking technique is thus…
TLD and OSLD dosimetry systems for remote audits of radiotherapy external beam calibration.
Alvarez, P; Kry, S F; Stingo, F; Followill, D
2017-11-01
The Imaging and Radiation Oncology Core QA Center in Houston (IROC-H) performs remote dosimetry audits of more than 20,000 megavoltage photon and electron beams each year. Both a thermoluminescent dosimeter (TLD-100) and optically stimulated luminescent dosimeter (OSLD; nanoDot) system are commissioned for this task, with the OSLD system being predominant due to the more time-efficient read-out process. The measurement apparatus includes 3 TLD or 2 OSLD in an acrylic mini-phantom, which are irradiated by the institution under reference geometry. Dosimetry systems are calibrated based on the signal-to-dose conversion established with reference dosimeters irradiated in a Co-60 beam, using a reference dose of 300 cGy for TLD and 100 cGy for OSLD. The uncertainty in the dose determination is 1.3% for TLD and 1.6% for OSLD at the one sigma level. This accuracy allows for a tolerance of ±5% to be used.
The CMS High Level Trigger System: Experience and Future Development
NASA Astrophysics Data System (ADS)
Bauer, G.; Behrens, U.; Bowen, M.; Branson, J.; Bukowiec, S.; Cittolin, S.; Coarasa, J. A.; Deldicque, C.; Dobson, M.; Dupont, A.; Erhan, S.; Flossdorf, A.; Gigi, D.; Glege, F.; Gomez-Reino, R.; Hartl, C.; Hegeman, J.; Holzner, A.; Hwong, Y. L.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Polese, G.; Racz, A.; Raginel, O.; Sakulin, H.; Sani, M.; Schwick, C.; Shpakov, D.; Simon, S.; Spataru, A. C.; Sumorok, K.
2012-12-01
The CMS experiment at the LHC features a two-level trigger system. Events accepted by the first level trigger, at a maximum rate of 100 kHz, are read out by the Data Acquisition system (DAQ), and subsequently assembled in memory in a farm of computers running a software high-level trigger (HLT), which selects interesting events for offline storage and analysis at a rate of order few hundred Hz. The HLT algorithms consist of sequences of offline-style reconstruction and filtering modules, executed on a farm of 0(10000) CPU cores built from commodity hardware. Experience from the operation of the HLT system in the collider run 2010/2011 is reported. The current architecture of the CMS HLT, its integration with the CMS reconstruction framework and the CMS DAQ, are discussed in the light of future development. The possible short- and medium-term evolution of the HLT software infrastructure to support extensions of the HLT computing power, and to address remaining performance and maintenance issues, are discussed.
A Monitoring System for the LHCb Data Flow
NASA Astrophysics Data System (ADS)
Barbosa, João; Gaspar, Clara; Jost, Beat; Frank, Markus; Cardoso, Luis G.
2017-06-01
The LHCb experiment uses the LHC accelerator for the collisions that produce the physics data necessary for analysis. The data produced by the detector by measuring the results of the collisions at a rate of 40 MHz are read out by a complex data acquisition (DAQ) system, which is summarily described in this paper. Distributed systems of such dimensions rely on monitoring and control systems that account for the numerous faults that can happen throughout the whole operation. With this in mind, a new system was created to extend the monitoring of the readout system, in this case by providing an overview of what is happening in each stage of the DAQ process, starting in the hardware trigger performed right after the detector measurements and ending in the local storage of the experiment. This system, a complement to the current run control (experimental control system), intends to shorten reaction times when a problem occurs by providing the operators with detailed information of where a certain fault is occurring. The architecture of the tool and its utilization by the experiment operators are described in this paper.
Laser system for testing radiation imaging detector circuits
NASA Astrophysics Data System (ADS)
Zubrzycka, Weronika; Kasinski, Krzysztof
2015-09-01
Performance and functionality of radiation imaging detector circuits in charge and position measurement systems need to meet tight requirements. It is therefore necessary to thoroughly test sensors as well as read-out electronics. The major disadvantages of using radioactive sources or particle beams for testing are high financial expenses and limited accessibility. As an alternative short pulses of well-focused laser beam are often used for preliminary tests. There are number of laser-based devices available on the market, but very often their applicability in this field is limited. This paper describes concept, design and validation of laser system for testing silicon sensor based radiation imaging detector circuits. The emphasis is put on keeping overall costs low while achieving all required goals: mobility, flexible parameters, remote control and possibility of carrying out automated tests. The main part of the developed device is an optical pick-up unit (OPU) used in optical disc drives. The hardware includes FPGA-controlled circuits for laser positioning in 2 dimensions (horizontal and vertical), precision timing (frequency and number) and amplitude (diode current) of short ns-scale (3.2 ns) light pulses. The system is controlled via USB interface by a dedicated LabVIEW-based application enabling full manual or semi-automated test procedures.
RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia.
Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D; Smirnakis, Stelios; Aslanides, Ioannis M
2017-01-01
Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia.
RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia
Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D.; Smirnakis, Stelios; Aslanides, Ioannis M.
2017-01-01
Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia. PMID:28800632
Metacognitive Prompt Overdose: Positive and Negative Effects of Prompts in iSTART
ERIC Educational Resources Information Center
McCarthy, Kathryn S.; Johnson, Amy M.; Likens, Aaron D.; Martin, Zachary; McNamara, Danielle S.
2017-01-01
Interactive Strategy Training for Active Reading and Thinking (iSTART) is an intelligent tutoring system that supports reading comprehension through self-explanation (SE) training. This study tested how two metacognitive features, presented in a 2 x 2 design, affected students' SE scores during training. The "performance notification"…
Precision Attitude Determination for an Infrared Space Telescope
NASA Technical Reports Server (NTRS)
Benford, Dominic J.
2008-01-01
We have developed performance simulations for a precision attitude determination system using a focal plane star tracker on an infrared space telescope. The telescope is being designed for the Destiny mission to measure cosmologically distant supernovae as one of the candidate implementations for the Joint Dark Energy Mission. Repeat observations of the supernovae require attitude control at the level of 0.010 arcseconds (0.05 microradians) during integrations and at repeat intervals up to and over a year. While absolute accuracy is not required, the repoint precision is challenging. We have simulated the performance of a focal plane star tracker in a multidimensional parameter space, including pixel size, read noise, and readout rate. Systematic errors such as proper motion, velocity aberration, and parallax can be measured and compensated out. Our prediction is that a relative attitude determination accuracy of 0.001 to 0.002 arcseconds (0.005 to 0.010 microradians) will be achievable.
High-Density Droplet Microarray of Individually Addressable Electrochemical Cells.
Zhang, Huijie; Oellers, Tobias; Feng, Wenqian; Abdulazim, Tarik; Saw, En Ning; Ludwig, Alfred; Levkin, Pavel A; Plumeré, Nicolas
2017-06-06
Microarray technology has shown great potential for various types of high-throughput screening applications. The main read-out methods of most microarray platforms, however, are based on optical techniques, limiting the scope of potential applications of such powerful screening technology. Electrochemical methods possess numerous complementary advantages over optical detection methods, including its label-free nature, capability of quantitative monitoring of various reporter molecules, and the ability to not only detect but also address compositions of individual compartments. However, application of electrochemical methods for the purpose of high-throughput screening remains very limited. In this work, we develop a high-density individually addressable electrochemical droplet microarray (eDMA). The eDMA allows for the detection of redox-active reporter molecules irrespective of their electrochemical reversibility in individual nanoliter-sized droplets. Orthogonal band microelectrodes are arranged to form at their intersections an array of three-electrode systems for precise control of the applied potential, which enables direct read-out of the current related to analyte detection. The band microelectrode array is covered with a layer of permeable porous polymethacrylate functionalized with a highly hydrophobic-hydrophilic pattern, forming spatially separated nanoliter-sized droplets on top of each electrochemical cell. Electrochemical characterization of single droplets demonstrates that the underlying electrode system is accessible to redox-active molecules through the hydrophilic polymeric pattern and that the nonwettable hydrophobic boundaries can spatially separate neighboring cells effectively. The eDMA technology opens the possibility to combine the high-throughput biochemical or living cell screenings using the droplet microarray platform with the sequential electrochemical read-out of individual droplets.
The HEXITEC Hard X-Ray Pixelated CdTe Imager for Fast Solar Observations
NASA Technical Reports Server (NTRS)
Baumgartner, Wayne H.; Christe, Steven D.; Ryan, Daniel; Inglis, Andrew R.; Shih, Albert Y.; Gregory, Kyle; Wilson, Matt; Seller, Paul; Gaskin, Jessica; Wilson-Hodge, Colleen
2016-01-01
There is an increasing demand in solar and astrophysics for high resolution X-ray spectroscopic imaging. Such observations would present ground breaking opportunities to study the poorly understood high energy processes in our solar system and beyond, such as solar flares, X-ray binaries, and active galactic nuclei. However, such observations require a new breed of solid state detectors sensitive to high energy X-rays with fine independent pixels to sub-sample the point spread function (PSF) of the X-ray optics. For solar observations in particular, they must also be capable of handling very high count rates as photon fluxes from solar flares often cause pile up and saturation in present generation detectors. The Rutherford Appleton Laboratory (RAL) has recently developed a new cadmium telluride (CdTe) detector system, called HEXITEC (High Energy X-ray Imaging Technology). It is an 80 x 80 array of 250 micron independent pixels sensitive in the 2-200 keV band and capable of a high full frame read out rate of 10 kHz. HEXITEC provides the smallest independently read out CdTe pixels currently available, and are well matched to the few arcsecond PSF produced by current and next generation hard X-ray focusing optics. NASA's Goddard and Marshall Space Flight Centers are collaborating with RAL to develop these detectors for use on future space borne hard X-ray focusing telescopes. We show the latest results on HEXITEC's imaging capability, energy resolution, high read out rate, and reveal it to be ideal for such future instruments.
Quantum noise in the mirror-field system: A field theoretic approach
NASA Astrophysics Data System (ADS)
Hsiang, Jen-Tsung; Wu, Tai-Hung; Lee, Da-Shin; King, Sun-Kun; Wu, Chun-Hsien
2013-02-01
We revisit the quantum noise problem in the mirror-field system by a field-theoretic approach. Here a perfectly reflecting mirror is illuminated by a single-mode coherent state of the massless scalar field. The associated radiation pressure is described by a surface integral of the stress-tensor of the field. The read-out field is measured by a monopole detector, from which the effective distance between the detector and mirror can be obtained. In the slow-motion limit of the mirror, this field-theoretic approach allows to identify various sources of quantum noise that all in all leads to uncertainty of the read-out measurement. In addition to well-known sources from shot noise and radiation pressure fluctuations, a new source of noise is found from field fluctuations modified by the mirror's displacement. Correlation between different sources of noise can be established in the read-out measurement as the consequence of interference between the incident field and the field reflected off the mirror. In the case of negative correlation, we found that the uncertainty can be lowered than the value predicted by the standard quantum limit. Since the particle-number approach is often used in quantum optics, we compared results obtained by both approaches and examine its validity. We also derive a Langevin equation that describes the stochastic dynamics of the mirror. The underlying fluctuation-dissipation relation is briefly mentioned. Finally we discuss the backreaction induced by the radiation pressure. It will alter the mean displacement of the mirror, but we argue this backreaction can be ignored for a slowly moving mirror.
van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo
2017-04-01
The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items. Two weeks after training, trained items were assessed again in a retention test. Participants either received phonics feedback, in which each word was spelled out and repeated; word feedback, in which each word was repeated; or no feedback. During the training, both good and poor readers improved in accuracy and speed. The increase in speed was stronger for poor readers than for good readers. The good readers demonstrated a stronger increase for pseudowords than for words. This increase in speed was most prominent in the first four sessions. Two weeks after training, the levels of accuracy and speed were retained. Furthermore, transfer effects on speed were found for pseudowords in both groups of readers. Good readers performed most accurately during the training when they received no feedback while poor readers performed most accurately during the training with the help of phonics feedback. However, feedback did not differentiate for reading speed or for effects after the training. The effects of repeated word reading were found to be stronger for poor readers than for good readers. Moreover, these effects were found to be stronger for pseudowords than for words. This indicates that repeated word reading can be seen as an important trigger for the improvement of decoding skills.
NASA Astrophysics Data System (ADS)
Crepaldi, M.; Chiolerio, A.; Tommasi, T.; Hidalgo, D.; Canavese, G.; Stassi, S.; Demarchi, D.; Pirri, F. C.
2013-05-01
Microbial Fuel Cells (MFCs) are energy sources which generate electrical charge thanks to bacteria metabolism. Although functionally similar to chemical fuel cells (both including reactants and two electrodes, and anode and cathode), they have substantial advantages, e.g. 1) operation at ambient temperature and pressure; 2) use of neutral electrolytes and avoidance of expensive catalysts (e.g. platinum); 3) operation using organic wastes. An MFC can be effectively used in environments where ubiquitous networking requires the wireless monitoring of energy sources. We then report on a simple monitoring system for MFC comprising an ultra-low-power Impulse-Radio Ultra-Wide-Band Transmitter (TX) operating in the low 0-960MHz band and a nanostructured piezoresistive pressure sensor connected to a discrete component digital read-out circuit. The sensor comprises an insulating matrix of polydimethylsiloxane and nanostructured multi-branched copper microparticles as conductive filler. Applied mechanical stress induces a sample deformation that modulates the mean distance between particles, i.e. the current flow. The read-out circuit encodes pressure as a pulse rate variation, with an absolute sensitivity to the generated MFC voltage. Pulses with variable repetition frequency can encode battery health: the pressure sensor can be directly connected to the cells membrane to read excessive pressure. A prototype system comprises two MFCs connected in series to power both the UWB transmitter which consumes 40μW and the read-out circuit. The two MFC generate an open circuit voltage of 1.0+/-0.1V. Each MFC prototype has a total volume of 0.34L and is formed by two circular Poly(methyl methacrylate) (PMMA) chambers (anode and cathode) separated by a cation exchange membrane. The paper reports on the prototype and measurements towards a final solution which embeds all functionalities within a MFC cell. Our solution is conceived to provide energy sources integrating energy management and health monitoring capabilities to sensor nodes which are not connected to the energy grid.
Comparison of different speech tasks among adults who stutter and adults who do not stutter
Ritto, Ana Paula; Costa, Julia Biancalana; Juste, Fabiola Staróbole; de Andrade, Claudia Regina Furquim
2016-01-01
OBJECTIVES: In this study, we compared the performance of both fluent speakers and people who stutter in three different speaking situations: monologue speech, oral reading and choral reading. This study follows the assumption that the neuromotor control of speech can be influenced by external auditory stimuli in both speakers who stutter and speakers who do not stutter. METHOD: Seventeen adults who stutter and seventeen adults who do not stutter were assessed in three speaking tasks: monologue, oral reading (solo reading aloud) and choral reading (reading in unison with the evaluator). Speech fluency and rate were measured for each task. RESULTS: The participants who stuttered had a lower frequency of stuttering during choral reading than during monologue and oral reading. CONCLUSIONS: According to the dual premotor system model, choral speech enhanced fluency by providing external cues for the timing of each syllable compensating for deficient internal cues. PMID:27074176
Development of n-in-p pixel modules for the ATLAS upgrade at HL-LHC
NASA Astrophysics Data System (ADS)
Macchiolo, A.; Nisius, R.; Savic, N.; Terzo, S.
2016-09-01
Thin planar pixel modules are promising candidates to instrument the inner layers of the new ATLAS pixel detector for HL-LHC, thanks to the reduced contribution to the material budget and their high charge collection efficiency after irradiation. 100-200 μm thick sensors, interconnected to FE-I4 read-out chips, have been characterized with radioactive sources and beam tests at the CERN-SPS and DESY. The results of these measurements are reported for devices before and after irradiation up to a fluence of 14 ×1015 neq /cm2 . The charge collection and tracking efficiency of the different sensor thicknesses are compared. The outlook for future planar pixel sensor production is discussed, with a focus on sensor design with the pixel pitches (50×50 and 25×100 μm2) foreseen for the RD53 Collaboration read-out chip in 65 nm CMOS technology. An optimization of the biasing structures in the pixel cells is required to avoid the hit efficiency loss presently observed in the punch-through region after irradiation. For this purpose the performance of different layouts have been compared in FE-I4 compatible sensors at various fluence levels by using beam test data. Highly segmented sensors will represent a challenge for the tracking in the forward region of the pixel system at HL-LHC. In order to reproduce the performance of 50×50 μm2 pixels at high pseudo-rapidity values, FE-I4 compatible planar pixel sensors have been studied before and after irradiation in beam tests at high incidence angle (80°) with respect to the short pixel direction. Results on cluster shapes, charge collection and hit efficiency will be shown.
YES, Indeed! Improv and the Art of Library Science
ERIC Educational Resources Information Center
Belben, Cathy
2010-01-01
Librarians can--and should--be on the lookout for new and unique ways to improve their instructional skill sets and service. One out-of-the-box opportunity to consider is to study--by reading, watching, or participating in--improvisational theater. Improv games and theater are like life: performers who may or may not know each other are given…
Enhancing Adolescent Literacy Achievement through Integration of Technology in the Classroom
ERIC Educational Resources Information Center
Sternberg, Betty J.; Kaplan, Karen A.; Borck, Jennifer E.
2007-01-01
Adolescent literacy achievement across the United States is in crisis. More than eight million students in grades 4 to 12 are identified as struggling readers. These students, who perform below grade level in reading and writing, are at high risk for failure in all content subjects and ultimately for dropping out of school. Professionals in the…
In-situ Geochronology on the Mars 2020 Rover with KArLE (The Potassium-Argon Laser Experiment)
NASA Technical Reports Server (NTRS)
Cohen, Barbara A.; Li, Z. -H.; Miller, J. S.; Devismes, D.; Swindle, T. D.; Schwenzer, S. P.; Kelley, S. P.; Zacny, K. A.; Roark, S. E.; Hardaway, L. R.;
2014-01-01
A successful Mars exploration program has revealed chapters of Mars history, but in this book, the pages are ripped out of the binding and scattered across the surface. An examination of each page reveals interesting information, but there is no way to read the book in a logical order. Geochronology is the tool that puts page number onto the individual pages, and allows the book of Martian history to be read in its proper order. The KArLE experiment performs the first dedicated in situ geochronology investigation on Mars, bringing clarity to Mars 2020 samples and context to its landing site.
ERIC Educational Resources Information Center
Clark, Christina
2012-01-01
This research was funded by law firm Slaughter and May and carried out with 21,000 children and young people across the UK. One of its key findings is that children and young people are reading less as their lives get more crowded. In 2005 the researchers found that four young people in 10 read daily outside of class. This research carried out at…
Mahé, Gwendoline; Zesiger, Pascal; Laganaro, Marina
2015-11-15
Most of our knowledge on the time-course of the mechanisms involved in reading derived from electrophysiological studies is based on lexical decision tasks. By contrast, very few ERP studies investigated the processes involved in reading aloud. It has been suggested that the lexical decision task provides a good index of the processes occurring during reading aloud, with only late processing differences related to task response modalities. However, some behavioral studies reported different sensitivity to psycholinguistic factors between the two tasks, suggesting that print processing could differ at earlier processing stages. The aim of the present study was thus to carry out an ERP comparison between lexical decision and reading aloud in order to determine when print processing differs between these two tasks. Twenty native French speakers performed a lexical decision task and a reading aloud task with the same written stimuli. Results revealed different electrophysiological patterns on both waveform amplitudes and global topography between lexical decision and reading aloud from about 140 ms after stimulus presentation for both words and pseudowords, i.e., as early as the N170 component. These results suggest that only very early, low-level visual processes are common to the two tasks which differ in core processes. Taken together, our main finding questions the use of the lexical decision task as an appropriate paradigm to investigate reading processes and warns against generalizing its results to word reading. Copyright © 2015 Elsevier Inc. All rights reserved.
Walker, Robin; Bryan, Lauren; Harvey, Hannah; Riazi, Afsane; Anderson, Stephen J
2016-07-01
Technological devices such as smartphones and tablets are widely available and increasingly used as visual aids. This study evaluated the use of a novel app for tablets (MD_evReader) developed as a reading aid for individuals with a central field loss resulting from macular degeneration. The MD_evReader app scrolls text as single lines (similar to a news ticker) and is intended to enhance reading performance using the eccentric viewing technique by both reducing the demands on the eye movement system and minimising the deleterious effects of perceptual crowding. Reading performance with scrolling text was compared with reading static sentences, also presented on a tablet computer. Twenty-six people with low vision (diagnosis of macular degeneration) read static or dynamic text (scrolled from right to left), presented as a single line at high contrast on a tablet device. Reading error rates and comprehension were recorded for both text formats, and the participant's subjective experience of reading with the app was assessed using a simple questionnaire. The average reading speed for static and dynamic text was not significantly different and equal to or greater than 85 words per minute. The comprehension scores for both text formats were also similar, equal to approximately 95% correct. However, reading error rates were significantly (p = 0.02) less for dynamic text than for static text. The participants' questionnaire ratings of their reading experience with the MD_evReader were highly positive and indicated a preference for reading with this app compared with their usual method. Our data show that reading performance with scrolling text is at least equal to that achieved with static text and in some respects (reading error rate) is better than static text. Bespoke apps informed by an understanding of the underlying sensorimotor processes involved in a cognitive task such as reading have excellent potential as aids for people with visual impairments. © 2016 The Authors Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.
Sotiropoulos, Andreas; Hanley, J Richard
The relationship between spelling, written word recognition, and picture naming is investigated in a study of seven bilingual adults who have developmental surface dysgraphia in both Greek (their first language) and English (their second language). Four of the cases also performed poorly at orthographic lexical decision in both languages. This finding is consistent with similar results in Italian that have been taken as evidence of a developmental impairment to a single orthographic system that is used for both reading and spelling. The remaining three participants performed well at orthographic lexical decision. At first sight, preserved lexical decision in surface dysgraphia is less easy to explain in terms of a shared orthographic system. However, the results of subsequent experiments showed clear parallels between the nature of the reading and spelling difficulties that these three individuals experienced, consistent with the existence of a single orthographic system. The different patterns that were observed were consistent with the claims of Friedmann and Lukov (2008. Developmental surface dyslexias. Cortex, 44, 1146-1160) that several distinct sub-types of developmental surface dyslexia exist. We show that individual differences in spelling in surface dysgraphia are also consistent with these sub-types; there are different developmental deficits that can give rise, in an individual, to a combination of surface dyslexia and dysgraphia. Finally, we compare the theoretical framework used by Friedmann and her colleagues that is based upon the architecture of the DRC model with an account that relies instead upon the Triangle model of reading].
An Analysis of the Concepts of Reading. Final Report.
ERIC Educational Resources Information Center
Ross, James F.
An initial philosophical analysis of "reading" has yielded; (1) that there cannot be a general definition of reading; (2) that the "focal" senses of "to read" indicate that reading is a form of linguistic perception carried out through the exercise of general linguistic abilities, adapted to a visual input of inscriptions with inherent linguistic…
Sporer, Siegfried L; Kaminski, Kristina S; Davids, Maike C; McQuiston, Dawn
2016-11-01
When witnesses report a crime, police usually ask for a description of the perpetrator. Several studies suggested that verbalising faces leads to a detriment in identification performance (verbal overshadowing effect [VOE]) but the effect has been difficult to replicate. Here, we sought to reverse the VOE by inducing context reinstatement as a system variable through re-reading one's own description before an identification task. Participants (N = 208) watched a video film and were then dismissed (control group), only described the perpetrator, or described and later re-read their own descriptions before identification in either target-present or target-absent lineups after a 2-day or a 5-week delay. Identification accuracy was significantly higher after re-reading (85.0%) than in the no description control group (62.5%) irrespective of target presence. Data were internally replicated using a second target and corroborated by several small meta-analyses. Identification accuracy was related to description quality. Moreover, there was a tendency towards a verbal facilitation effect (VFE) rather than a VOE. Receiver operating characteristic (ROC) curve analyses confirm that our findings are not due to a shift in response bias but truly reflect improvement of recognition performance. Differences in the ecological validity of study paradigms are discussed.
Paper-based electrochemical sensing platform with integral battery and electrochromic read-out.
Liu, Hong; Crooks, Richard M
2012-03-06
We report a battery-powered, microelectrochemical sensing platform that reports its output using an electrochromic display. The platform is fabricated based on paper fluidics and uses a Prussian blue spot electrodeposited on an indium-doped tin oxide thin film as the electrochromic indicator. The integrated metal/air battery powers both the electrochemical sensor and the electrochromic read-out, which are in electrical contact via a paper reservoir. The sample activates the battery and the presence of analyte in the sample initiates the color change of the Prussian blue spot. The entire system is assembled on the lab bench, without the need for cleanroom facilities. The applicability of the device to point-of-care sensing is demonstrated by qualitative detection of 0.1 mM glucose and H(2)O(2) in artificial urine samples.
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
Dealing with Quantifier Scope Ambiguity in Natural Language Understanding
ERIC Educational Resources Information Center
Hafezi Manshadi, Mohammad
2014-01-01
Quantifier scope disambiguation (QSD) is one of the most challenging problems in deep natural language understanding (NLU) systems. The most popular approach for dealing with QSD is to simply leave the semantic representation (scope-) underspecified and to incrementally add constraints to filter out unwanted readings. Scope underspecification has…
The impact of workload on the ability to localize audible alarms.
Edworthy, Judy; Reid, Scott; Peel, Katie; Lock, Samantha; Williams, Jessica; Newbury, Chloe; Foster, Joseph; Farrington, Martin
2018-10-01
Very little is known about people's ability to localize sound under varying workload conditions, though it would be expected that increasing workload should degrade performance. A set of eight auditory clinical alarms already known to have relatively high localizability (the ease with which their location is identified) when tested alone were tested in six conditions where workload was varied. Participants were required to indicate the location of a series of alarms emanating at random from one of eight speaker locations. Additionally, they were asked to read, carry out mental arithmetic tasks, be exposed to typical ICU noise, or carry out either the reading task or the mental arithmetic task in ICU noise. Performance in the localizability task was best in the control condition (no secondary task) and worst in those tasks which involved both a secondary task and noise. The data does therefore demonstrate the typical pattern of increasing workload affecting a primary task in an area where there is little data. In addition, the data demonstrates that performance in the control condition results in a missed alarm on one in ten occurrences, whereas performance in the heaviest workload conditions results in a missed alarm on every fourth occurrence. This finding has implications for the understanding of both 'inattentional deafness' and 'alarm fatigue' in clinical environments. Copyright © 2018 Elsevier Ltd. All rights reserved.
Development of low-cost high-performance multispectral camera system at Banpil
NASA Astrophysics Data System (ADS)
Oduor, Patrick; Mizuno, Genki; Olah, Robert; Dutta, Achyut K.
2014-05-01
Banpil Photonics (Banpil) has developed a low-cost high-performance multispectral camera system for Visible to Short- Wave Infrared (VIS-SWIR) imaging for the most demanding high-sensitivity and high-speed military, commercial and industrial applications. The 640x512 pixel InGaAs uncooled camera system is designed to provide a compact, smallform factor to within a cubic inch, high sensitivity needing less than 100 electrons, high dynamic range exceeding 190 dB, high-frame rates greater than 1000 frames per second (FPS) at full resolution, and low power consumption below 1W. This is practically all the feature benefits highly desirable in military imaging applications to expand deployment to every warfighter, while also maintaining a low-cost structure demanded for scaling into commercial markets. This paper describes Banpil's development of the camera system including the features of the image sensor with an innovation integrating advanced digital electronics functionality, which has made the confluence of high-performance capabilities on the same imaging platform practical at low cost. It discusses the strategies employed including innovations of the key components (e.g. focal plane array (FPA) and Read-Out Integrated Circuitry (ROIC)) within our control while maintaining a fabless model, and strategic collaboration with partners to attain additional cost reductions on optics, electronics, and packaging. We highlight the challenges and potential opportunities for further cost reductions to achieve a goal of a sub-$1000 uncooled high-performance camera system. Finally, a brief overview of emerging military, commercial and industrial applications that will benefit from this high performance imaging system and their forecast cost structure is presented.
The utility of kindergarten teacher ratings for predicting low academic achievement in first grade.
Teisl, J T; Mazzocco, M M; Myers, G F
2001-01-01
The purpose of this study was to assess the predictive value of kindergarten teachers' ratings of pupils for later first-grade academic achievement. Kindergarten students were rated by their teachers on a variety of variables, including math and reading performance, teacher concerns, and amount of learning relative to peers. These variables were then analyzed with respect to outcome measures for math and reading ability administered in the first grade. The teachers' ratings of academic performance were significantly correlated with scores on the outcome measures. Analyses were also carried out to determine sensitivity, specificity, and predictive values of the different teacher ratings. The results indicated high overall accuracy, sensitivity, specificity, and negative predictive value for the ratings. Positive predictive value tended to be lower. A recommendation to follow from these results is that teacher ratings of this sort be used to determine which children should receive cognitive screening measures to further enhance identification of children at risk for learning disability. However, this recommendation is limited by the lack of empirically supported screening measures for math disability versus well-supported screening tools for reading disability.
The Just So Story--Obvious but False.
ERIC Educational Resources Information Center
Smith, Frank
2003-01-01
Considers how public opinion and entire theories of teaching reading are based in the false Just So story--Just Sound Out, and you can read. Explains why sounding out is a handicap. Suggests a better alternative, teaching by recognizing words. (SG)
Mossbridge, Julia; Zweig, Jacob; Grabowecky, Marcia; Suzuki, Satoru
2016-01-01
The perceptual system integrates synchronized auditory-visual signals in part to promote individuation of objects in cluttered environments. The processing of auditory-visual synchrony may more generally contribute to cognition by synchronizing internally generated multimodal signals. Reading is a prime example because the ability to synchronize internal phonological and/or lexical processing with visual orthographic processing may facilitate encoding of words and meanings. Consistent with this possibility, developmental and clinical research has suggested a link between reading performance and the ability to compare visual spatial/temporal patterns with auditory temporal patterns. Here, we provide converging behavioral and electrophysiological evidence suggesting that greater behavioral ability to judge auditory-visual synchrony (Experiment 1) and greater sensitivity of an electrophysiological marker of auditory-visual synchrony processing (Experiment 2) both predict superior reading comprehension performance, accounting for 16% and 25% of the variance, respectively. These results support the idea that the mechanisms that detect auditory-visual synchrony contribute to reading comprehension. PMID:28129060
Mossbridge, Julia; Zweig, Jacob; Grabowecky, Marcia; Suzuki, Satoru
2017-03-01
The perceptual system integrates synchronized auditory-visual signals in part to promote individuation of objects in cluttered environments. The processing of auditory-visual synchrony may more generally contribute to cognition by synchronizing internally generated multimodal signals. Reading is a prime example because the ability to synchronize internal phonological and/or lexical processing with visual orthographic processing may facilitate encoding of words and meanings. Consistent with this possibility, developmental and clinical research has suggested a link between reading performance and the ability to compare visual spatial/temporal patterns with auditory temporal patterns. Here, we provide converging behavioral and electrophysiological evidence suggesting that greater behavioral ability to judge auditory-visual synchrony (Experiment 1) and greater sensitivity of an electrophysiological marker of auditory-visual synchrony processing (Experiment 2) both predict superior reading comprehension performance, accounting for 16% and 25% of the variance, respectively. These results support the idea that the mechanisms that detect auditory-visual synchrony contribute to reading comprehension.
[A telemedicine electrocardiography system based on the component-architecture soft].
Potapov, I V; Selishchev, S V
2004-01-01
The paper deals with a universal component-oriented architecture for creating the telemedicine applications. The worked-out system ensures the ECG reading, pressure measurements and pulsometry. The system design comprises a central database server and a client telemedicine module. Data can be transmitted via different interfaces--from an ordinary local network to digital satellite phones. The data protection is guaranteed by microchip charts that were used to realize the authentication 3DES algorithm.
SPIDR, a general-purpose readout system for pixel ASICs
NASA Astrophysics Data System (ADS)
van der Heijden, B.; Visser, J.; van Beuzekom, M.; Boterenbrood, H.; Kulis, S.; Munneke, B.; Schreuder, F.
2017-02-01
The SPIDR (Speedy PIxel Detector Readout) system is a flexible general-purpose readout platform that can be easily adapted to test and characterize new and existing detector readout ASICs. It is originally designed for the readout of pixel ASICs from the Medipix/Timepix family, but other types of ASICs or front-end circuits can be read out as well. The SPIDR system consists of an FPGA board with memory and various communication interfaces, FPGA firmware, CPU subsystem and an API library on the PC . The FPGA firmware can be adapted to read out other ASICs by re-using IP blocks. The available IP blocks include a UDP packet builder, 1 and 10 Gigabit Ethernet MAC's and a "soft core" CPU . Currently the firmware is targeted at the Xilinx VC707 development board and at a custom board called Compact-SPIDR . The firmware can easily be ported to other Xilinx 7 series and ultra scale FPGAs. The gap between an ASIC and the data acquisition back-end is bridged by the SPIDR system. Using the high pin count VITA 57 FPGA Mezzanine Card (FMC) connector only a simple chip carrier PCB is required. A 1 and a 10 Gigabit Ethernet interface handle the connection to the back-end. These can be used simultaneously for high-speed data and configuration over separate channels. In addition to the FMC connector, configurable inputs and outputs are available for synchronization with other detectors. A high resolution (≈ 27 ps bin size) Time to Digital converter is provided for time stamping events in the detector. The SPIDR system is frequently used as readout for the Medipix3 and Timepix3 ASICs. Using the 10 Gigabit Ethernet interface it is possible to read out a single chip at full bandwidth or up to 12 chips at a reduced rate. Another recent application is the test-bed for the VeloPix ASIC, which is developed for the Vertex Detector of the LHCb experiment. In this case the SPIDR system processes the 20 Gbps scrambled data stream from the VeloPix and distributes it over four 10 Gigabit Ethernet links, and in addition provides the slow and fast control for the chip.
Development of preschool and academic skills in children born very preterm.
Aarnoudse-Moens, Cornelieke Sandrine Hanan; Oosterlaan, Jaap; Duivenvoorden, Hugo Joseph; van Goudoever, Johannes Bernard; Weisglas-Kuperus, Nynke
2011-01-01
To examine performance in preschool and academic skills in very preterm (gestational age ≤ 30 weeks) and term-born comparison children aged 4 to 12 years. Very preterm children (n = 200; mean age, 8.2 ± 2.5 years) born between 1996 and 2004 were compared with 230 term-born children (mean age, 8.3 ± 2.3). The Dutch National Pupil Monitoring System was used to measure preschool numerical reasoning and early linguistics, and primary school simple and complex word reading, reading comprehension, spelling, and mathematics/arithmetic. With univariate analyses of variance, we assessed the effects of preterm birth on performance across grades and on grade retention. In preschool, very preterm children performed comparably with term-born children in early linguistics, but perform more poorly (0.7 standard deviation [SD]) in numerical reasoning skills. In primary school, very preterm children scored 0.3 SD lower in complex word reading and 0.6 SD lower in mathematics/arithmetic, but performed comparably with peers in reading comprehension and spelling. They had a higher grade repeat rate (25.5%), although grade repeat did not improve their academic skills. Very preterm children do well in early linguistics, reading comprehension, and spelling, but have clinically significant deficits in numerical reasoning skills and mathematics/arithmetic, which persist with time. Copyright © 2011 Mosby, Inc. All rights reserved.
Koh, Charlynn Sher Lin; Lee, Hiang Kwee; Phan-Quang, Gia Chuong; Han, Xuemei; Lee, Mian Rong; Yang, Zhe; Ling, Xing Yi
2017-07-17
Liquid marbles are emergent microreactors owing to their isolated environment and the flexibility of materials used. Plasmonic liquid marbles (PLMs) are demonstrated as the smallest spectroelectrochemical microliter-scale reactor for concurrent spectro- and electrochemical analyses. The three-dimensional Ag shell of PLMs are exploited as a bifunctional surface-enhanced Raman scattering (SERS) platform and working electrode for redox process modulation. The combination of SERS and electrochemistry (EC) capabilities enables in situ molecular read-out of transient electrochemical species, and elucidate the potential-dependent and multi-step reaction dynamics. The 3D configuration of our PLM-based EC-SERS system exhibits 2-fold and 10-fold superior electrochemical and SERS performance than conventional 2D platforms. The rich molecular-level electrochemical insights and excellent EC-SERS capabilities offered by our 3D spectroelectrochemical system are pertinent in charge transfer processes. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
RICH upgrade in LHCb experiment
NASA Astrophysics Data System (ADS)
Pistone, A.; LHCb RICH Collaboration
2017-01-01
The LHCb experiment is dedicated to precision measurements of CP violation and rare decays of B hadrons at the Large Hadron Collider (LHC) at CERN (Geneva). The second long shutdown of the LHC is currently scheduled to begin in 2019. During this period the LHCb experiment with all its sub-detectors will be upgraded in order to run at an instantaneous luminosity of 2 × 10^{33} cm ^{-2} s ^{-1} , about a factor 5 higher than the current luminosity, and to read out data at a rate of 40MHz into a flexible software-based trigger. The Ring Imaging CHerenkov (RICH) system will require new photon detectors and modifications to the optics of the upstream detector. Tests of the prototype of the smallest constituent of the new RICH system have been performed during testbeam sessions at the North Area test beam facility at CERN in the last years.
Toward developing a standardized Arabic continuous text reading chart.
Alabdulkader, Balsam; Leat, Susan Jennifer
Near visual acuity is an essential measurement during an oculo-visual assessment. Short duration continuous text reading charts measure reading acuity and other aspects of reading performance. There is no standardized version of such chart in Arabic. The aim of this study is to create sentences of equal readability to use in the development of a standardized Arabic continuous text reading chart. Initially, 109 Arabic pairs of sentences were created for use in constructing a chart with similar layout to the Colenbrander chart. They were created to have the same grade level of difficulty and physical length. Fifty-three adults and sixteen children were recruited to validate the sentences. Reading speed in correct words per minute (CWPM) and standard length words per minute (SLWPM) was measured and errors were counted. Criteria based on reading speed and errors made in each sentence pair were used to exclude sentence pairs with more outlying characteristics, and to select the final group of sentence pairs. Forty-five sentence pairs were selected according to the elimination criteria. For adults, the average reading speed for the final sentences was 166 CWPM and 187 SLWPM and the average number of errors per sentence pair was 0.21. Childrens' average reading speed for the final group of sentences was 61 CWPM and 72 SLWPM. Their average error rate was 1.71. The reliability analysis showed that the final 45 sentence pairs are highly comparable. They will be used in constructing an Arabic short duration continuous text reading chart. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Science Enabling ASICs and FEEs for the JUICE and JEO Missions
NASA Technical Reports Server (NTRS)
Paschalidis, Nicholas; Sittler, Ed; Cooper, John; Christian, Eric; Moore, Tom
2011-01-01
A family of science enabling radiation hard Application Specific Integrated Circuits (ASICs), Front End Electronics (FEEs) and Event Processing Systems, with flight heritage on many NASA missions, is presented. These technologies play an important role in the miniaturization of instruments -and spacecraft systems- at the same time increasing performance and reducing power. The technologies target time of flight, position sensing, and energy measurements as well as standard housekeeping and telemetry functions for particle and fields instruments, but find applications in other instrument categories too. More specifically the technologies include: the TOF chip, 1D and 2D Delay Lines with MCP detectors, for high precision fast and low power time of flight and position sensing; the Energy chip for multichannel SSD readout with time over threshold and standard voltage read out for TDC and ADC digitization; Fast multi channel read out chip with commandable thresholds; the TRIO chip for multiplexed ADC and housekeeping etc. It should be mentioned that the ASICs include basic trigger capabilities to enable random event processing in a heavy background of penetrators and UV foreground. Typical instruments include time of flight versus energy and look angle particle analyzers such as: plasma composition, energetic particle, neutral atom imaging as well as fast plasma and deltaE/E ion/electron telescopes. Flight missions include: Cassini/LEMMS, IMAGE/HENA, MESSENGER/EPPS/MLA/X-ray/MLA, STEREO, PLUTO-NH/PEPSSI/LORI, IBEX-Lo, JUNO/JEDI, RBSP/RBSPICE, MMS/HPCA/EPD, SO/SIS. Given the proven capability on heavy radiation missions such as JUNO, MMS and RBSB, as well diverse long duration missions such as MESSENGER, PLUTO and Cassini, it is expected that these technologies will play an important role in the particle and fields (at least) instruments on the upcoming JUICE and JEO missions.
ERIC Educational Resources Information Center
Galdo, JoAnne Donnelly
2013-01-01
This study investigated the impact of Web 2.0-based literature response blogs on summer reading loss and student reading motivation. There is limited empirical research that connects summer reading and the use of social media as a means of maintaining reading levels of elementary aged students during out-of-school time. This study attempted to…
Diagnostic Utility of the Social Skills Improvement System Performance Screening Guide
ERIC Educational Resources Information Center
Krach, S. Kathleen; McCreery, Michael P.; Wang, Ye; Mohammadiamin, Houra; Cirks, Christen K.
2017-01-01
Researchers investigated the diagnostic utility of the Social Skills Improvement System: Performance Screening Guide (SSIS-PSG). Correlational, regression, receiver operating characteristic (ROC), and conditional probability analyses were run to compare ratings on the SSIS-PSG subscales of Prosocial Behavior, Reading Skills, and Math Skills, to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-09-28
Activities carried out by the American College of Radiology are described. Guidelines on radiographic techniques for radiological technicians were developed. Annual training sessions for technologists and physicians were conducted by the American College of Radiology Task Force on Pneumoconiosis. Regulations for performing chest x rays were reviewed. Program activities such as the 12-point International Labor Organization (ILO) classification scale for diagnosis of coal workers' pneumoconiosis, and the reporting form for use of the 1980 ILO classification system were reviewed. The American College of Radiology maintained liaison between NIOSH and other medical specialty societies such as the American College of Chestmore » Physicians, the College of American Pathologists, the American Medical Association, and the American Osteopathic College of Radiology. The American College of Radiology assisted NIOSH with the initiation, development, and maintenance of a quality control method to monitor and advise physicians on the reading of radiographs.« less
Lallier, Marie; Carreiras, Manuel
2018-02-01
Reading acquisition is one of the most complex and demanding learning processes faced by children in their first years of schooling. If reading acquisition is challenging in one language, how is it when reading is acquired simultaneously in two languages? What is the impact of bilingualism on the development of literacy? We review behavioral and neuroimaging evidence from alphabetic writing systems suggesting that early bilingualism modulates reading development. Particularly, we show that cross-linguistic variations and cross-linguistic transfer affect bilingual reading strategies as well as their cognitive underpinnings. We stress the fact that the impact of bilingualism on literacy acquisition depends on the specific combination of languages learned and does not manifest itself similarly across bilingual populations. We argue that these differences can be explained by variations due to orthographic depth in the grain sizes used to perform reading and reading-related tasks. Overall, we propose novel hypotheses to shed light on the behavioral and neural variability observed in reading skills among bilinguals.
Predicting Reading and Spelling Disorders: A 4-Year Prospective Cohort Study
Bigozzi, Lucia; Tarchi, Christian; Caudek, Corrado; Pinto, Giuliana
2016-01-01
In this 4-year prospective cohort study, children with a reading and spelling disorder, children with a spelling impairment, and children without a reading and/or spelling disorder (control group) in a transparent orthography were identified in third grade, and their emergent literacy performances in kindergarten compared retrospectively. Six hundred and forty-two Italian children participated. This cohort was followed from the last year of kindergarten to third grade. In kindergarten, the children were assessed in phonological awareness, conceptual knowledge of writing systems and textual competence. In third grade, 18 children with a reading and spelling impairment and 13 children with a spelling impairment were identified. Overall, conceptual knowledge of the writing system was the only statistically significant predictor of the clinical samples. No differences were found between the two clinical samples. PMID:27014145
ERIC Educational Resources Information Center
Hennings, Sara S.; Hughes, Kay E.
This paper provides a brief description of the development of the Diagnostic Assessments of Reading with Trial Teaching Strategies (DARTTS) program by F. G. Roswell and J. S. Chall. It also describes the editorial and statistical procedures that were used to validate the program for determining students' strengths and weaknesses in important areas…
ERIC Educational Resources Information Center
Moreira, Sylvia; Hamilton, Maryellen
2006-01-01
Rhyming tests have historically been used in the education system to assess reading readiness. English language learners (ELLs) have consistently scored poorly on these assessment tools. The current article examines a possible reason for this poor performance by ELLs. Specifically, the authors examined the relationship between semantic…
What about Me?: Individual Self-Assessment by Skill and Level of Language Instruction
ERIC Educational Resources Information Center
Brantmeier, Cindy; Vanderplank, Robert; Strube, Michael
2012-01-01
In an investigation with advanced language learners, Brantmeier [Brantmeier, C., 2006. "Advanced L2 learners and reading placement: self-assessment, computer based testing, and subsequent performance." "System" 34 (1), 15-35.] reports that self-assessment (SA) of second language (L2) reading ability, when measured with self-rated scales, is not an…
How to Reach First-Grade Struggling Readers: An Integrated Instructional Approach
ERIC Educational Resources Information Center
Solari, Emily J.; Denton, Carolyn A.; Haring, Christa
2017-01-01
Struggling readers who are in need of Tier 2 supplemental reading instruction within a multitier system of support (MTSS) or a response to intervention are defined as those who are performing in the bottom 20% in reading-related skills as compared with their classroom peers. An MTSS model is a framework for instruction that provides increasing…
Don't Throw out Paper and Pens Yet: On the Reading Habits of Students
ERIC Educational Resources Information Center
Davidovitch, Nitza; Yavich, Roman; Druckman, Eran
2016-01-01
This paper focuses on students' reading habits--whether traditional reading habits (print books) or modern reading habits (using a computer screen). We review the changes in students' reading habits over time, as part of other global changes, and explore whether corresponding digital pedagogies have evolved to address these changes. We examine…
Riddle appreciation and reading comprehension in Cantonese-speaking children.
Tang, Ivy N Y; To, Carol K S; Weekes, Brendan S
2013-10-01
Inference-making skills are necessary for reading comprehension. Training in riddle appreciation is an effective way to improve reading comprehension among English-speaking children. However, it is not clear whether these methods generalize to other writing systems. The goal of the present study was to investigate the relationship between inference-making skills, as measured by riddle appreciation ability, and reading comprehension performance in typically developing Cantonese-speaking children in the 4th grade. Forty Cantonese-speaking children between the ages of 9;1 (years;months) and 11;0 were given tests of riddle appreciation ability and reading comprehension. Chinese character reading and auditory comprehension abilities were also assessed using tests that had been standardized in Hong Kong. Regression analyses revealed that riddle appreciation ability explained a significant amount of variance in reading comprehension after variance due to character reading skills and auditory comprehension skills were first considered. Orthographic, lexical, morphological, and syntactic riddles were also significantly correlated with reading comprehension. Riddle appreciation ability predicts reading comprehension in Cantonese-speaking 4th-grade children. Therefore, training Cantonese speakers in riddle appreciation should improve their reading comprehension.
Connectionist neuropsychology: uncovering ultimate causes of acquired dyslexia.
Woollams, Anna M
2014-01-01
Acquired dyslexia offers a unique window on to the nature of the cognitive and neural architecture supporting skilled reading. This paper provides an integrative overview of recent empirical and computational work on acquired dyslexia within the context of the primary systems framework as implemented in connectionist neuropsychological models. This view proposes that damage to general visual, phonological or semantic processing abilities are the root causes of different forms of acquired dyslexia. Recent case-series behavioural evidence concerning pure alexia, phonological dyslexia and surface dyslexia that supports this perspective is presented. Lesion simulations of these findings within connectionist models of reading demonstrate the viability of this approach. The commitment of such models to learnt representations allows them to capture key aspects of performance in each type of acquired dyslexia, particularly the associated non-reading deficits, the role of relearning and the influence of individual differences in the premorbid state of the reading system. Identification of these factors not only advances our understanding of acquired dyslexia and the mechanisms of normal reading but they are also relevant to the complex interactions underpinning developmental reading disorders.
Connectionist neuropsychology: uncovering ultimate causes of acquired dyslexia
Woollams, Anna M.
2014-01-01
Acquired dyslexia offers a unique window on to the nature of the cognitive and neural architecture supporting skilled reading. This paper provides an integrative overview of recent empirical and computational work on acquired dyslexia within the context of the primary systems framework as implemented in connectionist neuropsychological models. This view proposes that damage to general visual, phonological or semantic processing abilities are the root causes of different forms of acquired dyslexia. Recent case-series behavioural evidence concerning pure alexia, phonological dyslexia and surface dyslexia that supports this perspective is presented. Lesion simulations of these findings within connectionist models of reading demonstrate the viability of this approach. The commitment of such models to learnt representations allows them to capture key aspects of performance in each type of acquired dyslexia, particularly the associated non-reading deficits, the role of relearning and the influence of individual differences in the premorbid state of the reading system. Identification of these factors not only advances our understanding of acquired dyslexia and the mechanisms of normal reading but they are also relevant to the complex interactions underpinning developmental reading disorders. PMID:24324241
The association between semantic dementia and surface dyslexia in Japanese.
Fushimi, Takao; Komori, Kenjiro; Ikeda, Manabu; Lambon Ralph, Matthew A; Patterson, Karalyn
2009-03-01
One theory about reading suggests that producing the correct pronunciations of written words, particularly less familiar words with an atypical spelling-sound relationship, relies in part on knowledge of the word's meaning. This hypothesis has been supported by reports of surface dyslexia in large case-series studies of English-speaking/reading patients with semantic dementia (SD), but would have increased credibility if it applied to other languages and writing systems as well. The hypothesis predicts that, of the two systems used to write Japanese, SD patients should be unimpaired at oral reading of kana because of its invariant relationship between orthography and phonology. By contrast, oral reading of kanji should be impaired in a graded fashion depending on the consistency characteristics of the kanji target words, with worst performance on words whose component characters take 'minority' (atypical) pronunciations, especially if the words are of lower frequency. Errors in kanji reading should primarily reflect assignment of more typical readings to the component characters in these atypical words. In the largest-ever-reported case series of Japanese patients with semantic dementia, we tested and confirmed this hypothesis.
NASA Astrophysics Data System (ADS)
Page, M. J.; Chan, N.; Breeveld, A. A.; Talavera, A.; Yershov, V.; Kennedy, T.; Kuin, N. P. M.; Hancock, B.; Smith, P. J.; Carter, M.
2017-04-01
The dynamic range of the XMM-Newton Optical Monitor (XMM-OM) is limited at the bright end by coincidence loss, the superposition of multiple photons in the individual frames recorded from its micro-channel-plate (MCP) intensified charge-coupled device (CCD) detector. One way to overcome this limitation is to use photons that arrive during the frame transfer of the CCD, forming vertical read-out streaks for bright sources. We calibrate these read-out streaks for photometry of bright sources observed with XMM-OM. The bright-source limit for read-out-streak photometry is set by the recharge time of the MCPs. For XMM-OM, we find that the MCP recharge time is 5.5 × 10-4 s. We determine that the effective bright limits for read-out-streak photometry with XMM-OM are approximately 1.5 mag brighter than the bright-source limits for normal aperture photometry in full-frame images. This translates into bright-source limits in Vega magnitudes of UVW2=7.1, UVM2=8.0, UVW1=9.4, U=10.5, B=11.5, V=10.2, and White=12.5 for data taken early in the mission. The limits brighten by up to 0.2 mag, depending on filter, over the course of the mission as the detector ages. The method is demonstrated by deriving UVW1 photometry for the symbiotic nova RR Telescopii, and the new photometry is used to constrain the e-folding time of its decaying ultraviolet (UV) emission. Using the read-out-streak method, we obtain photometry for 50 per cent of the missing UV source measurements in version 2.1 of the XMM-Newton Serendipitous UV Source Survey catalogue.
Electrocutaneous stimulation system for Braille reading.
Echenique, Ana Maria; Graffigna, Juan Pablo; Mut, Vicente
2010-01-01
This work is an assistive technology for people with visual disabilities and aims to facilitate access to written information in order to achieve better social inclusion and integration into work and educational activities. Two methods of electrical stimulation (by current and voltage) of the mechanoreceptors was tested to obtain tactile sensations on the fingertip. Current and voltage stimulation were tested in a Braille cell and line prototype, respectively. These prototypes are evaluated in 33 blind and visually impaired subjects. The result of experimentation with both methods showed that electrical stimulation causes sensations of touch defined in the fingertip. Better results in the Braille characters reading were obtained with current stimulation (85% accuracy). However this form of stimulation causes uncomfortable sensations. The latter feeling was minimized with the method of voltage stimulation, but with low efficiency (50% accuracy) in terms of identification of the characters. We concluded that electrical stimulation is a promising method for the development of a simple and unexpensive Braille reading system for blind people. We observed that voltage stimulation is preferred by the users. However, more experimental tests must be carry out in order to find the optimum values of the stimulus parameters and increase the accuracy the Braille characters reading.
Lamônica, Dionísia Aparecida Cusin; Ferraz, Plínio Marcos Duarte Pinto; Ferreira, Amanda Tragueta; Prado, Lívia Maria do; Abramides, Dagma Venturini Marquez; Gejão, Mariana Germano
2011-01-01
The Fragile X syndrome is the most frequent cause of inherited intellectual disability. The Dandy-Walker variant is a specific constellation of neuroradiological findings. The present study reports oral and written communication findings in a 15-year-old boy with clinical and molecular diagnosis of Fragile X syndrome and neuroimaging findings consistent with Dandy-Walker variant. The speech-language pathology and audiology evaluation was carried out using the Communicative Behavior Observation, the Phonology assessment of the ABFW - Child Language Test, the Phonological Abilities Profile, the Test of School Performance, and the Illinois Test of Psycholinguistic Abilities. Stomatognathic system and hearing assessments were also performed. It was observed: phonological, semantic, pragmatic and morphosyntactic deficits in oral language; deficits in psycholinguistic abilities (auditory reception, verbal expression, combination of sounds, auditory and visual sequential memory, auditory closure, auditory and visual association); and morphological and functional alterations in the stomatognathic system. Difficulties in decoding the graphical symbols were observed in reading. In writing, the subject presented omissions, agglutinations and multiple representations with the predominant use of vowels, besides difficulties in visuo-spatial organization. In mathematics, in spite of the numeric recognition, the participant didn't accomplish arithmetic operations. No alterations were observed in the peripheral hearing evaluation. The constellation of behavioral, cognitive, linguistic and perceptual symptoms described for Fragile X syndrome, in addition to the structural central nervous alterations observed in the Dandy-Walker variant, caused outstanding interferences in the development of communicative abilities, in reading and writing learning, and in the individual's social integration.
Performance of the fiber-optic low-coherent ground settlement sensor: From lab to field
NASA Astrophysics Data System (ADS)
Guo, Jingjing; Tan, Yanbin; Peng, Li; Chen, Jisong; Wei, Chuanjun; Zhang, Pinglei; Zhang, Tianhang; Alrabeei, Salah; Zhang, Zhe; Sun, Changsen
2018-04-01
A fiber-optic low-coherent interferometry sensor was developed to measure the ground settlement (GS) in an accuracy of the micrometer. The sensor combined optical techniques with liquid-contained chambers that were hydraulically connected together at the bottom by using a water-filled tube. The liquid surface inside each chamber was at the same level initially. The optical interferometry was employed to read out the liquid level changes, which following the GS happened at the place where the chamber was put on and, thereby, the GS information was calculated. The laboratory effort had demonstrated its potential in the practical application. Here, the denoising algorithms on the measurement signal were carried out based on the specific environment to ensure the accuracy and stability of the system in field applications. After that, we extended this technique to the high-speed railway. The 5-days continuous measurement proved that the designed system could be applied to monitor the GS of the high-speed railway piers and approached an accuracy of ±70 μm in the field situation with a reference compensation sensor. So the performance of the sensor was suitable to the GS monitoring problem in the high-speed railway. There, the difficulties were to meet the monitoring requirement of both a large span in space and its quite tiny and slow changes.
Keys to Reading among Middle School Children
ERIC Educational Resources Information Center
Smith, Nichole; Day, Barbara
2013-01-01
A recent decline in reading has become a major issue, as Americans are not reading out of necessity or as a leisure activity. In addition, a connection has been found between children's leisure reading habits and their level of academic achievement, causing even more concern. (Contains 1 table.)
School Librarians and the Teaching of Reading.
ERIC Educational Resources Information Center
Miller, Larry
1980-01-01
Points out the techniques and practices school librarians intuitively use to encourage and enhance reading by children and notes that cooperation between instructors and librarians can do much to improve children's reading skills. (RAA)
Does reading in shallow L1 orthography slow attrition of language-specific morphological structures?
Zaretsky, Elena; Bar-Shalom, Eva G
2010-01-01
This study looks at the relationship between L1 (Russian) attrition and L1 reading ability in Russian-English-speaking bilingual children. Ten Russian-English bilingual children and 10 adults participated in this study. Nine out of 10 children participants were born in the US and used L1 as their primary language of interaction within the family, but the intensity and the length of uninterrupted L1 exposure differed for each child. All participants were tested on perception (grammaticality judgement) and production (narrative) tasks to assess their sensitivity to and retention of the morphosyntactic structure of L1. All children showed some attrition of grammatical morphemes, specifically in the Russian systems of declension and conjugation; however, the degree of attrition correlated with reading ability in L1, i.e. children with L1 reading skills showed a lesser degree of attrition for some language-specific morphosyntactic structures. This finding shows interdependence of oral and reading skills and points to the role reading in language with shallow orthography may play in preservation of L1 grammatical structures in oral language. The implications for the clinical applications are also discussed.
Drift chamber readout system of the DIRAC experiment
NASA Astrophysics Data System (ADS)
Afanasyev, L.; Karpukhin, V.
2002-10-01
A drift chamber readout system of the DIRAC experiment at CERN is presented. The system is intended to read out the signals from planar chambers operating in a high current mode. The sense wire signals are digitized in the 16-channel time-to-digital converter boards which are plugged in the signal plane connectors. This design results in a reduced number of modules, a small number of cables and high noise immunity. The system has been successfully operating in the experiment since 1999.
NASA Astrophysics Data System (ADS)
Fu, Y.; Hu-Guo, C.; Dorokhov, A.; Pham, H.; Hu, Y.
2013-07-01
In order to exploit the ability to integrate a charge collecting electrode with analog and digital processing circuitry down to the pixel level, a new type of CMOS pixel sensors with full CMOS capability is presented in this paper. The pixel array is read out based on a column-parallel read-out architecture, where each pixel incorporates a diode, a preamplifier with a double sampling circuitry and a discriminator to completely eliminate analog read-out bottlenecks. The sensor featuring a pixel array of 8 rows and 32 columns with a pixel pitch of 80 μm×16 μm was fabricated in a 0.18 μm CMOS process. The behavior of each pixel-level discriminator isolated from the diode and the preamplifier was studied. The experimental results indicate that all in-pixel discriminators which are fully operational can provide significant improvements in the read-out speed and the power consumption of CMOS pixel sensors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorton, H.C.; Mengali, O.J.; Zacaroli, A.R.
A practical, prototype silicon p-n junction fast-neutron dosimeter, sensitive in the same range as human tissue, was developed, together with sn associated read-out circuit to facilitate the accurate measurement of accumulated dose. From both theoretical and experimental considerations, it was demonstrated that the dosimeter is essentially insensitive to the gamma and thermal components of a uranium fission spectrum. It was shown that accumulated damage effects appear to be environmentally stable up to an ambient temperature of 100 C. A rather raarked reversible temperature dependence of the read-out parameters requires either control of the read-out temperature or temperature compensation in themore » read-out device. A high degree of reproducibility of dosimeter characteristics from one device to another was not achieved. The lack of reproducibility was attributed to uncontrolled variables in the bulk silicon from which the devices are fabricated, and in the production procedure. (auth)« less
The Impact of Alignment Coaching on Christian Teachers' Worthy Performance
ERIC Educational Resources Information Center
Hines, Linda M.
2010-01-01
"The Impact of Alignment Coaching on Christian Teachers' Worthy Performance" uses Human Performance Technology and "teleonomics" (Gilbert 2007) to document several intersecting vantage points as one performance improvement system of alignment coaching (AC). Coaching relationships and accomplishments of consistently (daily) reading the Bible,…
ERIC Educational Resources Information Center
Qian, David D.
2008-01-01
In the last 15 years or so, language testing practitioners have increasingly favored assessing vocabulary in context. The discrete-point vocabulary measure used in the old version of the Test of English as a Foreign Language (TOEFL) has long been criticized for encouraging test candidates to memorize wordlists out of context although test items…
ERIC Educational Resources Information Center
McMillan, Wendy
2004-01-01
This paper is conceptually informed by a reading of Peter McLaren's work (1993). Drawing on the relationship that he signals between identity, narrative, and social action, it sets out to examine the ways in which identity shapes narratives of academic performance and consequent action. Specifically, I present the narratives of academic…
Attention Drainage Effect: How Background Music Effects Concentration in Taiwanese College Students
ERIC Educational Resources Information Center
Chou, Peter Tze-Ming
2010-01-01
The purpose of this study was to see whether different types of background music affect the performance of a reading comprehension task in Taiwanese college students. There are two major research questions in this study. First, this study tries to find out whether listening to music affect the learner's concentration when they are doing a task…
Do children with reading delay benefit from the use of personal FM systems in the classroom?
Purdy, Suzanne C; Smart, Jennifer L; Baily, Melissa; Sharma, Mridula
2009-12-01
FM systems have been used to compensate for poor signal-to-noise ratios in classrooms. This study evaluates benefits of a 6-week trial of personal FM systems used during the school day for children with reading delay aged 6-11 years, using a randomized control design. Teachers and children completed the LIFE-UK questionnaire. Test-retest reliability of the LIFE-UK children's version was confirmed in a separate group of 18 children from the same school. The 23 children in the FM group had significantly improved teacher ratings, and the children's ratings of classroom listening for difficult situations were significantly better after the trial. These changes did not occur for the 23 control-group children. Most children (92%) commented positively about the FM after the trial. It is likely that a longer FM trial or a specific reading intervention combined with FM will be required for the benefits of enhanced listening to affect performance on standardized reading tests.
Updates on the Transition-Edge Sensors and Multiplexed Readout for HOLMES
NASA Astrophysics Data System (ADS)
Puiu, A.; Becker, D.; Bennett, D.; Biasotti, M.; Borghesi, M.; Ceriale, V.; De Gerone, M.; Faverzani, M.; Ferri, E.; Fowler, J.; Gallucci, G.; Gard, J.; Hays-Wehle, J.; Hilton, G.; Giachero, A.; Mates, J.; Nucciotti, A.; Orlando, A.; Pessina, G.; Schmidt, D.; Swetz, D.; Ullom, J.; Vale, L.
2018-05-01
Measuring the neutrino mass is one of the most compelling issues in particle physics. HOLMES is an experiment for a direct measurement of the neutrino mass. HOLMES will perform a precise measurement of the end point of the electron capture decay spectrum of ^{163}Ho in order to extract information on the neutrino mass with a sensitivity as low as 1 eV. HOLMES, in its final configuration, will deploy a 1000-pixel array of low-temperature microcalorimeters: each calorimeter is made of an absorber, where the Ho atoms will be implanted, coupled to a transition-edge sensor (TES) thermometer. The detectors will be operated at the working temperature of 100 mK provided by a dilution refrigerator. In order to read out the 1000-detector array of HOLMES, a multiplexing system is necessary: the choice is to couple the transition-edge sensors to a multiplexed rf-SQUID. In this contribution we outline the progress made towards the final configuration of HOLMES regarding both the performances of the TES detectors and the characteristics of the multiplexing system.
NASA Technical Reports Server (NTRS)
Levinthal, E. C.; Payne, R. O.
1971-01-01
The design and construction of a system to automatically test HLP antigens are described. Major efforts were made to test and evaluate the performance of such a system, and compare its performance with nonautomatic tissue typing techniques. The system is based on the fluorochromatic cytotoxicity assay. Results show the system will work but is subject to malfunctions after a few samplings, and poses problems in showing correctly the necessary readings.
RSEQtools: a modular framework to analyze RNA-Seq data using compact, anonymized data summaries.
Habegger, Lukas; Sboner, Andrea; Gianoulis, Tara A; Rozowsky, Joel; Agarwal, Ashish; Snyder, Michael; Gerstein, Mark
2011-01-15
The advent of next-generation sequencing for functional genomics has given rise to quantities of sequence information that are often so large that they are difficult to handle. Moreover, sequence reads from a specific individual can contain sufficient information to potentially identify and genetically characterize that person, raising privacy concerns. In order to address these issues, we have developed the Mapped Read Format (MRF), a compact data summary format for both short and long read alignments that enables the anonymization of confidential sequence information, while allowing one to still carry out many functional genomics studies. We have developed a suite of tools (RSEQtools) that use this format for the analysis of RNA-Seq experiments. These tools consist of a set of modules that perform common tasks such as calculating gene expression values, generating signal tracks of mapped reads and segmenting that signal into actively transcribed regions. Moreover, the tools can readily be used to build customizable RNA-Seq workflows. In addition to the anonymization afforded by MRF, this format also facilitates the decoupling of the alignment of reads from downstream analyses. RSEQtools is implemented in C and the source code is available at http://rseqtools.gersteinlab.org/.
A front-end electronic system for large arrays of bolometers
NASA Astrophysics Data System (ADS)
Arnaboldi, C.; Carniti, P.; Cassina, L.; Gotti, C.; Liu, X.; Maino, M.; Pessina, G.; Rosenfeld, C.; Zhu, B. X.
2018-02-01
CUORE is an array of thermal calorimeters composed of 988 crystals held at about 10 mK, whose absorbed energy is read out with semiconductor thermistors. The composition of the crystal is TeO2, and the aim is the study of the double beta decay of 130Te on very long and stable runs. CUPID-0 is an array of 26 Zn82Se crystals with double thermistor readout to study the double beta decay of 82Se. In the present paper, we present an overview of the entire front-end electronic readout chain, from the preamplifier to the anti-aliasing filter. This overview includes motivations, design strategies, circuit implementation and performance results of the electronic system, including other auxiliary yet important elements like power supplies and the slow control communication system. The stringent requirements of stability on the very long experimental runs that are foreseen during CUORE and CUPID-0 operation, are achieved thanks to novel solutions of the front-end preamplifier and of the detector bias circuit setup.
Ultra-Low-Power Smart Electronic Nose System Based on Three-Dimensional Tin Oxide Nanotube Arrays.
Chen, Jiaqi; Chen, Zhuo; Boussaid, Farid; Zhang, Daquan; Pan, Xiaofang; Zhao, Huijuan; Bermak, Amine; Tsui, Chi-Ying; Wang, Xinran; Fan, Zhiyong
2018-06-04
In this work, we present a high-performance smart electronic nose (E-nose) system consisting of a multiplexed tin oxide (SnO 2 ) nanotube sensor array, read-out circuit, wireless data transmission unit, mobile phone receiver, and data processing application (App). Using the designed nanotube sensor device structure in conjunction with multiple electrode materials, high-sensitivity gas detection and discrimination have been achieved at room temperature, enabling a 1000 times reduction of the sensor's power consumption as compared to a conventional device using thin film SnO 2 . The experimental results demonstrate that the developed E-nose can identify indoor target gases using a simple vector-matching gas recognition algorithm. In addition, the fabricated E-nose has achieved state-of-the-art sensitivity for H 2 and benzene detection at room temperature with metal oxide sensors. Such a smart E-nose system can address the imperative needs for distributed environmental monitoring in smart homes, smart buildings, and smart cities.
BAE Systems' 17μm LWIR camera core for civil, commercial, and military applications
NASA Astrophysics Data System (ADS)
Lee, Jeffrey; Rodriguez, Christian; Blackwell, Richard
2013-06-01
Seventeen (17) µm pixel Long Wave Infrared (LWIR) Sensors based on vanadium oxide (VOx) micro-bolometers have been in full rate production at BAE Systems' Night Vision Sensors facility in Lexington, MA for the past five years.[1] We introduce here a commercial camera core product, the Airia-MTM imaging module, in a VGA format that reads out in 30 and 60Hz progressive modes. The camera core is architected to conserve power with all digital interfaces from the readout integrated circuit through video output. The architecture enables a variety of input/output interfaces including Camera Link, USB 2.0, micro-display drivers and optional RS-170 analog output supporting legacy systems. The modular board architecture of the electronics facilitates hardware upgrades allow us to capitalize on the latest high performance low power electronics developed for the mobile phones. Software and firmware is field upgradeable through a USB 2.0 port. The USB port also gives users access to up to 100 digitally stored (lossless) images.
A high performance hierarchical storage management system for the Canadian tier-1 centre at TRIUMF
NASA Astrophysics Data System (ADS)
Deatrich, D. C.; Liu, S. X.; Tafirout, R.
2010-04-01
We describe in this paper the design and implementation of Tapeguy, a high performance non-proprietary Hierarchical Storage Management (HSM) system which is interfaced to dCache for efficient tertiary storage operations. The system has been successfully implemented at the Canadian Tier-1 Centre at TRIUMF. The ATLAS experiment will collect a large amount of data (approximately 3.5 Petabytes each year). An efficient HSM system will play a crucial role in the success of the ATLAS Computing Model which is driven by intensive large-scale data analysis activities that will be performed on the Worldwide LHC Computing Grid infrastructure continuously. Tapeguy is Perl-based. It controls and manages data and tape libraries. Its architecture is scalable and includes Dataset Writing control, a Read-back Queuing mechanism and I/O tape drive load balancing as well as on-demand allocation of resources. A central MySQL database records metadata information for every file and transaction (for audit and performance evaluation), as well as an inventory of library elements. Tapeguy Dataset Writing was implemented to group files which are close in time and of similar type. Optional dataset path control dynamically allocates tape families and assign tapes to it. Tape flushing is based on various strategies: time, threshold or external callbacks mechanisms. Tapeguy Read-back Queuing reorders all read requests by using an elevator algorithm, avoiding unnecessary tape loading and unloading. Implementation of priorities will guarantee file delivery to all clients in a timely manner.
A Public Domain Software Library for Reading and Language Arts.
ERIC Educational Resources Information Center
Balajthy, Ernest
A three-year project carried out by the Microcomputers and Reading Committee of the New Jersey Reading Association involved the collection, improvement, and distribution of free microcomputer software (public domain programs) designed to deal with reading and writing skills. Acknowledging that this free software is not without limitations (poor…
An universal read-out controller
NASA Astrophysics Data System (ADS)
Manz, S.; Abel, N.; Gebelein, J.; Kebschull, U.
2010-11-01
Since 2007 we design and develop a ROC (read-out controller) for FAIR's data-acquisition. While our first implementation solely focused on the nXYTER, today we are also designing and implementing readout logic for the GET4 which is supposed to be part of the ToF detector. Furthermore, we fully support both Ethernet and Optical transport as two transparent solutions. The usage of a strict modularization of the Read Out Controller enables us to provide an Universal ROC where front-end specific logic and transport logic can be combined in a very flexible way. Fault tolerance techniques are only required for some of those modules and hence are only implemented there.
First images of a digital autoradiography system based on a Medipix2 hybrid silicon pixel detector.
Mettivier, Giovanni; Montesi, Maria Cristina; Russo, Paolo
2003-06-21
We present the first images of beta autoradiography obtained with the high-resolution hybrid pixel detector consisting of the Medipix2 single photon counting read-out chip bump-bonded to a 300 microm thick silicon pixel detector. This room temperature system has 256 x 256 square pixels of 55 microm pitch (total sensitive area of 14 x 14 mm2), with a double threshold discriminator and a 13-bit counter in each pixel. It is read out via a dedicated electronic interface and control software, also developed in the framework of the European Medipix2 Collaboration. Digital beta autoradiograms of 14C microscale standard strips (containing separate bands of increasing specific activity in the range 0.0038-32.9 kBq g(-1)) indicate system linearity down to a total background noise of 1.8 x 10(-3) counts mm(-2) s(-1). The minimum detectable activity is estimated to be 0.012 Bq for 36,000 s exposure and 0.023 Bq for 10,800 s exposure. The measured minimum detection threshold is less than 1600 electrons (equivalent to about 6 keV Si). This real-time system for beta autoradiography offers lower pixel pitch and higher sensitive area than the previous Medipix1-based system. It has a 14C sensitivity better than that of micro channel plate based systems, which, however, shows higher spatial resolution and sensitive area.
NASA Astrophysics Data System (ADS)
Bisogni, Maria Giuseppina
2006-04-01
In this paper we report on the performances and the first imaging test results of a digital mammographic demonstrator based on GaAs pixel detectors. The heart of this prototype is the X-ray detection unit, which is a GaAs pixel sensor read-out by the PCC/MEDIPIXI circuit. Since the active area of the sensor is 1 cm2, 18 detectors have been organized in two staggered rows of nine chips each. To cover the typical mammographic format (18 × 24 cm2) a linear scanning is performed by means of a stepper motor. The system is integrated in mammographic equipment comprehending the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies in collaboration with the universities of Ferrara, Roma “La Sapienza”, Pisa and the INFN.
Preschoolers' Reading Skills Benefit from One Modest Change by Teachers
ERIC Educational Resources Information Center
Grabmeier, Jeff
2012-01-01
A small change in how teachers and parents read aloud to preschoolers may provide a big boost to their reading skills later on, a new study found. That change involves making specific references to print in books while reading--such as pointing out letters and words on the pages, showing capital letters, and showing how they read from left to…
Writing to Read: A Meta-Analysis of the Impact of Writing and Writing Instruction on Reading
ERIC Educational Resources Information Center
Graham, Steve; Hebert, Michael
2011-01-01
Reading is critical to students' success in and out of school. One potential means for improving students' reading is writing. In this meta-analysis of true and quasi-experiments, Graham and Herbert present evidence that writing about material read improves students' comprehension of it; that teaching students how to write improves their reading…
Moving Stormwater Infrastructure from Real-time Control to Smart Systems
NASA Astrophysics Data System (ADS)
Wadzuk, B.; Bryant, S.; Lewellyn, C.; Zaremba, G.; Traver, R.
2017-12-01
Urban areas, especially combined sewer communities, are using green infrastructure (GI) systems (e.g. rain gardens, green roofs) to mitigate stormwater runoff volume, rate, and quality issues. Most municipal guidance and regulation limits these systems to static, passive designs that neither fully utilize the active hydrology of a GI system during and after a rainfall event, nor enable dynamic operational control. Real-time control (RTC) applied to GI is emerging, and under ideal model conditions has shown improved performance (i.e., greater volumes managed while minimizing downstream impact). There are a few RTC pilot field projects with promising results, such as on a cistern - green roof system there were only 30 overflow events out of 126 rain events and at a rain garden - cistern system only 1 of 81 events resulted in overflow. However, RTC does not get to a fully dynamic system as the initiation and consequent action is preset and static. In stormwater RTC systems, the initiation is typically a rain forecast or a sensor reading. At a rain garden - cistern system, a cistern that fills when raining is hard set to pump water to the rain garden 24 hours after the predicted rain ends. There have been instances where there is rain occurring or only a minimal amount of dry time for the rain garden to reestablish capacity for the pumped stored water. There is also no mechanism to automatically change the pump initiation time based on season or ambient conditions. A cistern - green roof system that uses stored water in an upstream cistern for green roof irrigation is initiated on a set soil moisture reading or a set irrigation volume daily. The soil moisture reading was rarely reached, so irrigation was often not initiated and the set daily irrigation volume did not vary over season. Moving from RTC to a smart system uses longer term and/or historical data to inform decisions beyond what a short-term forecast or real-time sensor can provide to give more context and flexibility in the initiation - consequent action logic. The use of the Standardized Precipitation Evapotranspiration Index as a back-cast and forecast tool to calculate an appropriate irrigation volume based on what rainfall is pending and whether the system is in drought state is used and discussed to move the GI systems into smart control.
Duval, Daphné; González-Guerrero, Ana Belén; Dante, Stefania; Osmond, Johann; Monge, Rosa; Fernández, Luis J; Zinoviev, Kirill E; Domínguez, Carlos; Lechuga, Laura M
2012-05-08
One of the main limitations for achieving truly lab-on-a-chip (LOC) devices for point-of-care diagnosis is the incorporation of the "on-chip" detection. Indeed, most of the state-of-the-art LOC devices usually require complex read-out instrumentation, losing the main advantages of portability and simplicity. In this context, we present our last advances towards the achievement of a portable and label-free LOC platform with highly sensitive "on-chip" detection by using nanophotonic biosensors. Bimodal waveguide interferometers fabricated by standard silicon processes have been integrated with sub-micronic grating couplers for efficient light in-coupling, showing a phase resolution of 6.6 × 10(-4)× 2π rad and a limit of detection of 3.3 × 10(-7) refractive index unit (RIU) in bulk. A 3D network of SU-8 polymer microfluidics monolithically assembled at the wafer-level was included, ensuring perfect sealing and compact packaging. To overcome some of the drawbacks inherent to interferometric read-outs, a novel all-optical wavelength modulation system has been implemented, providing a linear response and a direct read-out of the phase variation. Sensitivity, specificity and reproducibility of the wavelength modulated BiMW sensor has been demonstrated through the label-free immunodetection of the human hormone hTSH at picomolar level using a reliable biofunctionalization process.
Community Attitudes Toward Reading.
ERIC Educational Resources Information Center
Flynn, Austin M.
It became fashionable in the 1960's for members of the community to become involved with education, but at the same time this involvement has forced the two extreme groups in society, the rich and the poor, into an uneasy consensus about the public education system. The author points out several factors which help shape the community's attitude…
ERIC Educational Resources Information Center
Air Univ., Maxwell AFB, AL.
This booklet was prepared in response to a demand from Air Force Officers returning to academic study after being out of school for several years. Its main purpose is to help returning veterans learn how to study. The guide is divided into three sections: (1) the "Reconnaissance-Read-Recall" (RRR) system of study, (2) concepts in "How We Learn,"…
List processing software for the LeCroy 1821 Segment Manager Interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorries, T.; Moore, C.; Pordes, R.
1987-05-01
Many experiments at Fermilab now include some FASTBUS electronics in their data readout. The software reported in this paper provides general support for the LeCroy 1821 interface. The list processing device drivers allow FASTBUS data to be read out efficiently into the Fermilab Computing Department supported data acquisition systems.
NASA Astrophysics Data System (ADS)
Vykydal, Z.; Jakubek, J.; Holy, T.; Pospisil, S.
2006-04-01
This work is devoted to the development of a USB1.1 (Universal Serial Bus) based read out system for the Medipix2 detector to achieve maximum portability of this position sensitive detecting device. All necessary detector support is integrated into one compact system (80 × 50 × 20 mm3) including the detector bias source (up to 100 V). The read out interface can control external I2C
Novel approaches to optomechanical transduction
NASA Astrophysics Data System (ADS)
Cernotik, Ondrej; Hammerer, Klemens
In recent years, mechanical oscillators received attention as a promising tool for frequency conversion between microwaves and light. A general, bi-directional transducer with high efficiency is still far from reach of current technology; finding new strategies for optomechanical transduction allows us to relax the requirements and bring these systems closer to an experimental realization. An interesting example is generation of entanglement between two superconducting qubits using measurement and postselection. Here, the mechanical oscillators interacts directly with the superconducting transmon qubit in such a way that it feels a qubit-state dependent force. This force can then be read out using a cavity field; reading out two such systems sequentially realizes an effective total spin measurement. Starting from a suitable initial state and employing postselection, entanglement can be generated. Another interesting approach is to use an array of optomechanical transducers in which the output fields of one transducer are fed into the input of the next. The periodicity of the array results in a joint dispersion relation for the propagating microwave and optical fields. The resulting structure can be used to control the conversion bandwidth and forward and backward scattering.
Development of double-sided silicon strip detectors for solar hard x-ray observation
NASA Astrophysics Data System (ADS)
Saito, Shinya; Ishikawa, Shin-Nosuke; Watanabe, Shin; Odaka, Hirokazu; Sugimoto, Soichiro; Fukuyama, Taro; Kokubun, Motohide; Takahashi, Tadayuki; Terada, Yukikatsu; Tajima, Hiroyasu; Tanaka, Takaaki; Krucker, Säm; Christe, Steven; McBride, Steve; Glesener, Lindsay
2010-07-01
The Focusing Optics X-ray Solar Imager (FOXSI) is a rocket experiment scheduled for January 2011 launch. FOXSI observes 5 - 15 keV hard X-ray emission from quiet-region solar flares in order to study the acceleration process of electrons and the mechanism of coronal heating. For observing faint hard X-ray emission, FOXSI uses focusing optics for the first time in solar hard X-ray observation, and attains 100 times higher sensitivity than RHESSI, which is the present solar hard X-ray observing satellite. Now our group is working on developments of both Double-sided Silicon Strip Detector (DSSD) and read-out analog ASIC "VATA451" used for FOXSI. Our DSSD has a very fine strip pitch of 75 μm, which has sufficient position resolution for FOXSI mirrors with angular resolution (FWHM) of 12 arcseconds. DSSD also has high spectral resolution and efficiency in the FOXSI's energy range of 5 - 15 keV, when it is read out by our 64-channel analog ASIC. In advance of the FOXSI launch, we have established and tested a setup of 75 μm pitch DSSD bonded with "VATA451" ASICs. We successfully read out from almost all the channels of the detector, and proved ability to make a shadow image of tungsten plate. We also confirmed that our DSSD has energy resolution (FWHM) of 0.5 keV, lower threshold of 5 keV, and position resolution less than 63 μm. These performance satisfy FOXSI's requirements.
First results of a highly granulated 3D CdTe detector module for PET
NASA Astrophysics Data System (ADS)
Chmeissani, Mokhtar; Kolstein, Machiel; Macias-Montero, José Gabriel; Puigdengoles, Carles; García, Jorge; Prats, Xavier; Martínez, Ricardo
2018-01-01
We present the performance of a highly granulated 3D detector module for PET, consisting of a stack of pixelated CdTe detectors. Each detector module has 2 cm × 2 cm × 2 cm of CdTe material, subdivided into 4000 voxels, where each voxel has size 1 mm × 1 mm × 2 mm and is connected to its own read-out electronics via a BiSn solder ball. Each read-out channel consists of a preamp, a discriminator, a shaper, a peak-and-hold circuit and a 10 bits SAR ADC. The preamp has variable gain where at the maximum gain the ADC resolution is equivalent to 0.7 keV. Each ASIC chip reads 100 CdTe pixel channels and has one TDC to measure the time stamp of the triggered events, with a time resolution of less than 1 ns. With the bias voltage set at -250 V mm-1 and for 17838 working channels out of a total of 20 000, we have obtained an average energy resolution of 2.2% FWHM for 511 keV photons. For 511 keV photons that have undergone Compton scattering, we measured an energy resolution of 3.2% FWHM. A timing resolution for PET coincidence events of 60 ns FWHM was found.
In vivo fluorescence lifetime tomography of a FRET probe expressed in mouse
McGinty, James; Stuckey, Daniel W.; Soloviev, Vadim Y.; Laine, Romain; Wylezinska-Arridge, Marzena; Wells, Dominic J.; Arridge, Simon R.; French, Paul M. W.; Hajnal, Joseph V.; Sardini, Alessandro
2011-01-01
Förster resonance energy transfer (FRET) is a powerful biological tool for reading out cell signaling processes. In vivo use of FRET is challenging because of the scattering properties of bulk tissue. By combining diffuse fluorescence tomography with fluorescence lifetime imaging (FLIM), implemented using wide-field time-gated detection of fluorescence excited by ultrashort laser pulses in a tomographic imaging system and applying inverse scattering algorithms, we can reconstruct the three dimensional spatial localization of fluorescence quantum efficiency and lifetime. We demonstrate in vivo spatial mapping of FRET between genetically expressed fluorescent proteins in live mice read out using FLIM. Following transfection by electroporation, mouse hind leg muscles were imaged in vivo and the emission of free donor (eGFP) in the presence of free acceptor (mCherry) could be clearly distinguished from the fluorescence of the donor when directly linked to the acceptor in a tandem (eGFP-mCherry) FRET construct. PMID:21750768
The effect of coloured overlays and lenses on reading: a systematic review of the literature.
Griffiths, Philip G; Taylor, Robert H; Henderson, Lisa M; Barrett, Brendan T
2016-09-01
There are many anecdotal claims and research reports that coloured lenses and overlays improve reading performance. Here we present the results of a systematic review of this literature and examine the quality of the evidence. We systematically reviewed the literature concerning the effect of coloured lenses or overlays on reading performance by searching the PsychInfo, Medline and Embase databases. This revealed 51 published items (containing 54 data sets). Given that different systems are in use for issuing coloured overlays or lenses, we reviewed the evidence under four separate system headings (Intuitive, Irlen, Harris/Chromagen and Other), classifying each published item using the Cochrane Risk of Bias tool. Although the different colour systems have been subjected to different amounts of scientific scrutiny, the results do not differ according to the system type, or whether the sample under investigation was classified as having visual stress (or a similarly defined condition), reading difficulty, or both. The majority of studies are subject to 'high' or 'uncertain' risk of bias in one or more key aspects of study design or outcome, with studies at lower risk from bias providing less support for the benefit of coloured lenses/overlays on reading ability. While many studies report improvements with coloured lenses, the effect size is generally small and/or similar to the improvement found with a placebo condition. We discuss the strengths and shortcomings of the published literature and, whilst acknowledging the difficulties associated with conducting trials of this type, offer some suggestions about how future trials might be conducted. Consistent with previous reviews and advice from several professional bodies, we conclude that the use of coloured lenses or overlays to ameliorate reading difficulties cannot be endorsed and that any benefits reported by individuals in clinical settings are likely to be the result of placebo, practice or Hawthorne effects. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Fast word reading in pure alexia: "fast, yet serial".
Bormann, Tobias; Wolfer, Sascha; Hachmann, Wibke; Neubauer, Claudia; Konieczny, Lars
2015-01-01
Pure alexia is a severe impairment of word reading in which individuals process letters serially with a pronounced length effect. Yet, there is considerable variation in the performance of alexic readers with generally very slow, but also occasionally fast responses, an observation addressed rarely in previous reports. It has been suggested that "fast" responses in pure alexia reflect residual parallel letter processing or that they may even be subserved by an independent reading system. Four experiments assessed fast and slow reading in a participant (DN) with pure alexia. Two behavioral experiments investigated frequency, neighborhood, and length effects in forced fast reading. Two further experiments measured eye movements when DN was forced to read quickly, or could respond faster because words were easier to process. Taken together, there was little support for the proposal that "qualitatively different" mechanisms or reading strategies underlie both types of responses in DN. Instead, fast responses are argued to be generated by the same serial-reading strategy.
Anxiety and Academic Reading Performance among Malay ESL Learners
ERIC Educational Resources Information Center
Mohd. Zin, Zuhana; Rafik-Galea, Shameem
2010-01-01
Research into the factors that contribute to reading performance decrement in L2 reading among ESL university students is still being extensively researched in the context of ELT. This is because successful academic performance is highly dependent on good reading ability. While it is widely accepted that poor reading performance is due to lack of…
Core Knowledge and the Emergence of Symbols: The Case of Maps
ERIC Educational Resources Information Center
Huang, Yi; Spelke, Elizabeth S.
2015-01-01
Map reading is unique to humans but is present in people of diverse cultures, at ages as young as 4 years old. Here, we explore the nature and sources of this ability and ask both what geometric information young children use in maps and what nonsymbolic systems are associated with their map-reading performance. Four-year-old children were given…
ERIC Educational Resources Information Center
Koskinen, Patricia S.; And Others
This project investigated the effectiveness of using closed-captioned television in the teaching of reading to learning-disabled and hearing-impared students. Seven teachers of learning disabled students, and 45 students ranging in age from 8 to 13 years, from a large Maryland public school system participated in this study. The first two of nine…
ERIC Educational Resources Information Center
Chevins, Peter F. D.
2005-01-01
This article describes a study of the effects of partial replacement of lectures with a system of prescribed reading, supported by weekly objective testing in a second year animal physiology module. Formative tests with feedback within 24 hours were followed a week later with summative tests on the same material, utilising a proportion of the same…
ERIC Educational Resources Information Center
Chen, Chih-Ming; Huang, Sheng-Hui
2014-01-01
Due to the rapid development of information technology, web-based learning has become a dominant trend. That is, learners can often learn anytime and anywhere without being restricted by time and space. Autonomic learning primarily occurs in web-based learning environments, and self-regulated learning (SRL) is key to autonomic learning…
Learning surface molecular structures via machine vision
NASA Astrophysics Data System (ADS)
Ziatdinov, Maxim; Maksov, Artem; Kalinin, Sergei V.
2017-08-01
Recent advances in high resolution scanning transmission electron and scanning probe microscopies have allowed researchers to perform measurements of materials structural parameters and functional properties in real space with a picometre precision. In many technologically relevant atomic and/or molecular systems, however, the information of interest is distributed spatially in a non-uniform manner and may have a complex multi-dimensional nature. One of the critical issues, therefore, lies in being able to accurately identify (`read out') all the individual building blocks in different atomic/molecular architectures, as well as more complex patterns that these blocks may form, on a scale of hundreds and thousands of individual atomic/molecular units. Here we employ machine vision to read and recognize complex molecular assemblies on surfaces. Specifically, we combine Markov random field model and convolutional neural networks to classify structural and rotational states of all individual building blocks in molecular assembly on the metallic surface visualized in high-resolution scanning tunneling microscopy measurements. We show how the obtained full decoding of the system allows us to directly construct a pair density function—a centerpiece in analysis of disorder-property relationship paradigm—as well as to analyze spatial correlations between multiple order parameters at the nanoscale, and elucidate reaction pathway involving molecular conformation changes. The method represents a significant shift in our way of analyzing atomic and/or molecular resolved microscopic images and can be applied to variety of other microscopic measurements of structural, electronic, and magnetic orders in different condensed matter systems.
Albion: the UK 3rd generation high-performance thermal imaging programme
NASA Astrophysics Data System (ADS)
McEwen, R. K.; Lupton, M.; Lawrence, M.; Knowles, P.; Wilson, M.; Dennis, P. N. J.; Gordon, N. T.; Lees, D. J.; Parsons, J. F.
2007-04-01
The first generation of high performance thermal imaging sensors in the UK was based on two axis opto-mechanical scanning systems and small (4-16 element) arrays of the SPRITE detector, developed during the 1970s. Almost two decades later, a 2nd Generation system, STAIRS C was introduced, based on single axis scanning and a long linear array of approximately 3000 elements. The UK has now begun the industrialisation of 3 rd Generation High Performance Thermal Imaging under a programme known as "Albion". Three new high performance cadmium mercury telluride arrays are being manufactured. The CMT material is grown by MOVPE on low cost substrates and bump bonded to the silicon read out circuit (ROIC). To maintain low production costs, all three detectors are designed to fit with existing standard Integrated Detector Cooling Assemblies (IDCAs). The two largest focal planes are conventional devices operating in the MWIR and LWIR spectral bands. A smaller format LWIR device is also described which has a smart ROIC, enabling much longer stare times than are feasible with conventional pixel circuits, thus achieving very high sensitivity. A new reference surface technology for thermal imaging sensors is described, based on Negative Luminescence (NL), which offers several advantages over conventional peltier references, improving the quality of the Non-Uniformity Correction (NUC) algorithms.