Eikel, Daniel; Henion, Jack
2011-08-30
An automated surface-sampling technique called liquid extraction surface analysis (LESA), coupled with infusion nano-electrospray high-resolution mass spectrometry and tandem mass spectrometry (MS/MS), is described and applied to the qualitative determination of surface chemical residues resulting from the artificial spraying of selected fresh fruits and vegetables with representative pesticides. Each of the targeted pesticides was readily detected with both high-resolution and full-scan collision-induced dissociation (CID) mass spectra. In the case of simazine and sevin, a mass resolution of 100,000 was insufficient to distinguish the isobaric protonated molecules for these compounds. When the surface of a spinach leaf was analyzed by LESA, trace levels of diazinon were readily detected on the spinach purchased directly from a supermarket before they were sprayed with the five-pesticide mixture. A 30 s rinse under hot running tap water appeared to quantitatively remove all remaining residues of this pesticide. Diazinon was readily detected by LESA analysis on the skin of the artificially sprayed spinach. Finally, incurred pyrimethanil at a level of 169 ppb in a batch slurry of homogenized apples was analyzed by LESA and this pesticide was readily detected by both high-resolution mass spectrometry and full-scan CID mass spectrometry, thus showing that pesticides may also be detected in whole fruit homogenized samples. This report shows that representative pesticides on fruit and vegetable surfaces present at levels 20-fold below generally allowed EPA tolerance levels are readily detected and confirmed by the title technologies making LESA-MS as interesting screening method for food safety purposes. Copyright © 2011 John Wiley & Sons, Ltd.
Quantification of birefringence readily measures the level of muscle damage in zebrafish
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, Joachim, E-mail: Joachim.Berger@Monash.edu; Sztal, Tamar; Currie, Peter D.
2012-07-13
Highlights: Black-Right-Pointing-Pointer Report of an unbiased quantification of the birefringence of muscle of fish larvae. Black-Right-Pointing-Pointer Quantification method readily identifies level of overall muscle damage. Black-Right-Pointing-Pointer Compare zebrafish muscle mutants for level of phenotype severity. Black-Right-Pointing-Pointer Proposed tool to survey treatments that aim to ameliorate muscular dystrophy. -- Abstract: Muscular dystrophies are a group of genetic disorders that progressively weaken and degenerate muscle. Many zebrafish models for human muscular dystrophies have been generated and analysed, including dystrophin-deficient zebrafish mutants dmd that model Duchenne Muscular Dystrophy. Under polarised light the zebrafish muscle can be detected as a bright area in anmore » otherwise dark background. This light effect, called birefringence, results from the diffraction of polarised light through the pseudo-crystalline array of the muscle sarcomeres. Muscle damage, as seen in zebrafish models for muscular dystrophies, can readily be detected by a reduction in the birefringence. Therefore, birefringence is a very sensitive indicator of overall muscle integrity within larval zebrafish. Unbiased documentation of the birefringence followed by densitometric measurement enables the quantification of the birefringence of zebrafish larvae. Thereby, the overall level of muscle integrity can be detected, allowing the identification and categorisation of zebrafish muscle mutants. In addition, we propose that the establish protocol can be used to analyse treatments aimed at ameliorating dystrophic zebrafish models.« less
Weerasinghe, Sujith V W; Jang, You-Jin; Fontana, Robert J; Omary, M Bishr
2014-08-01
Several serum markers are used to assess hepatocyte damage, but they have limitations related to etiology specificity and prognostication. Identification of novel hepatocyte-specific biomarkers could provide important prognostic information and better pathogenesis classification. We tested the hypothesis that hepatocyte-selective biomarkers are released after subjecting isolated mouse hepatocytes to Fas-ligand-mediated apoptosis. Proteomic analysis of hepatocyte culture medium identified the mitochondrial matrix protein carbamoyl phosphate synthetase-1 (CPS1) among the most readily detected proteins that are released by apoptotic hepatocytes. CPS1 was also detected in mouse serum upon acute challenge with Fas-ligand or acetaminophen and in hepatocytes upon hypoosmotic stress, independent of hepatocyte caspase activation. Furthermore, CPS1 was observed in sera of mice chronically fed the hepatotoxin 3,5-diethoxycarbonyl-1,4-dihydrocollidine. Mouse CPS1 detectability was similar in serum and plasma, and its half-life was 126 ± 9 min. Immune staining showed that CPS1 localized to mouse hepatocytes but not ductal cells. Analysis of a few serum samples from patients with acute liver failure (ALF) due to acetaminophen, Wilson disease, or ischemia showed readily detectable CPS1 that was not observed in several patients with chronic viral hepatitis or in control donors. Notably, CPS1 rapidly decreased to undetectable levels in sera of patients with acetaminophen-related ALF who ultimately recovered, while alanine aminotransferase levels remained elevated. Therefore, CPS1 becomes readily detectable upon hepatocyte apoptotic and necrotic death in culture or in vivo. Its abundance and short serum half-life, compared with alanine aminotransferase, suggest that it may be a useful prognostic biomarker in human and mouse liver injury. Copyright © 2014 the American Physiological Society.
Chatterjee, Gaurav; McGraw, Claire; Kasturirangan, Srinath; Schulz, Philip
2012-01-01
Protein misfolding and aggregation is a critically important feature in many devastating neurodegenerative diseases, therefore characterization of the CSF concentration profiles of selected key forms and morphologies of proteins involved in these diseases, including β-amyloid (Aβ) and α-synuclein (a-syn), can be an effective diagnostic assay for these diseases. CSF levels of tau and Aβ have been shown to have great promise as biomarkers for Alzheimer’s disease. However since the onset and progression of many neurodegenerative diseases have been strongly correlated with the presence of soluble oligomeric aggregates of proteins including various Aβ and a-syn aggregate species, specific detection and quantification of levels of each of these different toxic protein species in CSF may provide a simple and accurate means to presymptomatically diagnose and distinguish between these diseases. Here we show that the presence of different protein morphologies in human CSF samples can be readily detected using highly selective morphology specific reagents in conjunction with a sensitive electronic biosensor. We further show that these morphology specific reagents can readily distinguish between post-mortem CSF samples from AD, PD and cognitively normal sources. These studies suggest that detection of specific oligomeric aggregate species holds great promise as sensitive biomarkers for neurodegenerative disease. PMID:22076255
Do, Hongdo; Dobrovic, Alexander
2009-01-01
Background Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations. We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Results Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions. LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. Conclusion LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations. PMID:19811662
Do, Hongdo; Dobrovic, Alexander
2009-10-08
Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations.We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions.LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations.
Real-time Series Resistance Monitoring in PV Systems; NREL (National Renewable Energy Laboratory)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deceglie, M. G.; Silverman, T. J.; Marion, B.
We apply the physical principles of a familiar method, suns-Voc, to a new application: the real-time detection of series resistance changes in modules and systems operating outside. The real-time series resistance (RTSR) method that we describe avoids the need for collecting IV curves or constructing full series-resistance-free IV curves. RTSR is most readily deployable at the module level on apply the physical principles of a familiar method, suns-Voc, to a new application: the real-time detection of series resistance changes in modules and systems operating outside. The real-time series resistance (RTSR) method that we describe avoids the need for collecting IVmore » curves or constructing full series-resistance-free IV curves. RTSR is most readily deployable at the module level on micro-inverters or module-integrated electronics, but it can also be extended to full strings. Automated detection of series resistance increases can provide early warnings of some of the most common reliability issues, which also pose fire risks, including broken ribbons, broken solder bonds, and contact problems in the junction or combiner box. We describe the method in detail and describe a sample application to data collected from modules operating in the field.« less
Bacon, Siobhán; Engelbrecht, Britta; Schmid, Jasmin; Pfeiffer, Shona; Gallagher, Ross; McCarthy, Ailbhe; Burke, Marie; Concannon, Caoimhín; Prehn, Jochen H. M.; Byrne, Maria M.
2015-01-01
MicroRNA (miRNA) are a class of non-coding, 19–25 nucleotide RNA critical for network-level regulation of gene expression. miRNA serve as paracrine signaling molecules. Using an unbiased array approach, we previously identified elevated levels of miR-224 and miR-103 to be associated with a monogenic form of diabetes; HNF1A-MODY. miR-224 is a novel miRNA in the field of diabetes. We sought to explore the role of miR-224 as a potential biomarker in diabetes, and whether such diabetes-associated-miRNA can also be detected in the urine of patients. Absolute levels of miR-224 and miR-103 were determined in the urine of n = 144 individuals including carriers of a HNF1A mutation, participants with type 1 diabetes mellitus (T1DM), type 2 diabetes mellitus (T2DM) and normal controls. Expression levels were correlated with clinical and biochemical parameters. miR-224 was significantly elevated in the urine of carriers of a HNF1A mutation and participants with T1DM. miR-103 was highly expressed in urine across all diabetes cohorts when compared to controls. For both miR-224 and-103, we found a significant correlation between serum and urine levels (p < 0.01). We demonstrate that miRNA can be readily detected in the urine independent of clinical indices of renal dysfunction. We surmise that the differential expression levels of miR-224 in both HNF1A-MODY mutation carriers and T1DM may be an attempt to compensate for beta-cell demise. PMID:26110317
Large area nuclear particle detectors using ET materials
NASA Technical Reports Server (NTRS)
1987-01-01
The purpose of this SBIR Phase 1 feasibility effort was to demonstrate the usefulness of Quantex electron-trapping (ET) materials for spatial detection of nuclear particles over large areas. This demonstration entailed evaluating the prompt visible scintillation as nuclear particles impinged on films of ET materials, and subsequently detecting the nuclear particle impingement information pattern stored in the ET material, by means of the visible-wavelength luminescence produced by near-infrared interrogation. Readily useful levels of scintillation and luminescence outputs are demonstrated.
Evaluation of Nonferrous Metals as Potential In Vivo Tracers of Transferrin-Based Therapeutics
NASA Astrophysics Data System (ADS)
Zhao, Hanwei; Wang, Shunhai; Nguyen, Son N.; Elci, S. Gokhan; Kaltashov, Igor A.
2016-02-01
Transferrin (Tf) is a promising candidate for targeted drug delivery. While development of such products is impossible without the ability to monitor biodistribution of Tf-drug conjugates in tissues and reliable measurements of their levels in blood and other biological fluids, the presence of very abundant endogenous Tf presents a significant impediment to such efforts. Several noncognate metals have been evaluated in this work as possible tracers of exogenous transferrin in complex biological matrices using inductively coupled plasma mass spectrometry (ICP MS) as a detection tool. Placing Ni(II) on a His-tag of recombinant Tf resulted in formation of a marginally stable protein-metal complex, which readily transfers the metal to ubiquitous physiological scavengers, such as serum albumin. An alternative strategy targeted iron-binding pockets of Tf, where cognate Fe(III) was replaced by metal ions known to bind this protein. Both Ga(III) and In(III) were evaluated, with the latter being vastly superior as a tracer (stronger binding to Tf unaffected by the presence of metal scavengers and the retained ability to associate with Tf receptor). Spiking serum with indium-loaded Tf followed by ICP MS detection demonstrated that protein quantities as low as 0.04 nM can be readily detected in animal blood. Combining laser ablation with ICP MS detection allows distribution of exogenous Tf to be mapped within animal tissue cross-sections with spatial resolution exceeding 100 μm. The method can be readily extended to a range of other therapeutics where metalloproteins are used as either carriers or payloads.
NASA Astrophysics Data System (ADS)
McEvoy, Thomas Richard; Wolthusen, Stephen D.
Recent research on intrusion detection in supervisory data acquisition and control (SCADA) and DCS systems has focused on anomaly detection at protocol level based on the well-defined nature of traffic on such networks. Here, we consider attacks which compromise sensors or actuators (including physical manipulation), where intrusion may not be readily apparent as data and computational states can be controlled to give an appearance of normality, and sensor and control systems have limited accuracy. To counter these, we propose to consider indirect relations between sensor readings to detect such attacks through concurrent observations as determined by control laws and constraints.
Characterization of Neutron-Induced Defects in Isotopically Enriched Lithium Tetraborate
2011-03-01
that efficiently captures and transmutes neutrons into more readily detected forms of material or energy. Neutron detection is desirable to detect...be used to transmute neutrons into a more readily detectable particle or energy. Upon absorbing a thermal neutron, 6Li undergoes the reaction, 6 1...both 6Li and 10B in natural abundances unless deliberately enriched. In addition to the direct reactions, 6Li or 7Li and 16O can transmute neutrons
Concorde noise-induced building vibrations: John F. Kennedy International Airport
NASA Technical Reports Server (NTRS)
Mayes, W. H.; Stephens, D. G.; Deloach, R.; Cawthorn, J. M.; Holmes, H. K.; Lewis, R. B.; Holliday, B. G.; Ward, D. W.; Miller, W. T.
1978-01-01
Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.
Rapid Waterborne Pathogen Detection with Mobile Electronics.
Wu, Tsung-Feng; Chen, Yu-Chen; Wang, Wei-Chung; Kucknoor, Ashwini S; Lin, Che-Jen; Lo, Yu-Hwa; Yao, Chun-Wei; Lian, Ian
2017-06-09
Pathogen detection in water samples, without complex and time consuming procedures such as fluorescent-labeling or culture-based incubation, is essential to public safety. We propose an immunoagglutination-based protocol together with the microfluidic device to quantify pathogen levels directly from water samples. Utilizing ubiquitous complementary metal-oxide-semiconductor (CMOS) imagers from mobile electronics, a low-cost and one-step reaction detection protocol is developed to enable field detection for waterborne pathogens. 10 mL of pathogen-containing water samples was processed using the developed protocol including filtration enrichment, immune-reaction detection and imaging processing. The limit of detection of 10 E. coli O157:H7 cells/10 mL has been demonstrated within 10 min of turnaround time. The protocol can readily be integrated into a mobile electronics such as smartphones for rapid and reproducible field detection of waterborne pathogens.
Angelone, Bonnie L; Levin, Daniel T; Simons, Daniel J
2003-01-01
Observers typically detect changes to central objects more readily than changes to marginal objects, but they sometimes miss changes to central, attended objects as well. However, even if observers do not report such changes, they may be able to recognize the changed object. In three experiments we explored change detection and recognition memory for several types of changes to central objects in motion pictures. Observers who failed to detect a change still performed at above chance levels on a recognition task in almost all conditions. In addition, observers who detected the change were no more accurate in their recognition than those who did not detect the change. Despite large differences in the detectability of changes across conditions, those observers who missed the change did not vary in their ability to recognize the changing object.
Portable nuclear material detector and process
Hofstetter, Kenneth J [Aiken, SC; Fulghum, Charles K [Aiken, SC; Harpring, Lawrence J [North Augusta, SC; Huffman, Russell K [Augusta, GA; Varble, Donald L [Evans, GA
2008-04-01
A portable, hand held, multi-sensor radiation detector is disclosed. The detection apparatus has a plurality of spaced sensor locations which are contained within a flexible housing. The detection apparatus, when suspended from an elevation, will readily assume a substantially straight, vertical orientation and may be used to monitor radiation levels from shipping containers. The flexible detection array can also assume a variety of other orientations to facilitate any unique container shapes or to conform to various physical requirements with respect to deployment of the detection array. The output of each sensor within the array is processed by at least one CPU which provides information in a usable form to a user interface. The user interface is used to provide the power requirements and operating instructions to the operational components within the detection array.
Wei, Fang; Cheng, Scott; Korin, Yael; Reed, Elaine F; Gjertson, David; Ho, Chih-ming; Gritsch, H Albin; Veale, Jeffrey
2012-09-18
Kidney transplant recipients who have abnormally high creatinine levels in their blood often have allograft dysfunction secondary to rejection. Creatinine has become the preferred marker for renal dysfunction and is readily available in hospital clinical settings. We developed a rapid and accurate polymer-based electrochemical point-of-care (POC) assay for creatinine detection from whole blood to identify allograft dysfunction. The creatinine concentrations of 19 blood samples from transplant recipients were measured directly from clinical serum samples by the conducting polymer-based electrochemical (EC) sensor arrays. These measurements were compared to the traditional clinical laboratory assay. The time required for detection was <5 min from sample loading. Sensitivity of the detection was found to be 0.46 mg/dL of creatinine with only 40 μL sample in the creatinine concentration range of 0 mg/dL to 11.33 mg/dL. Signal levels that were detected electrochemically correlated closely with the creatinine blood concentration detected by the UCLA Ronald Reagan Medical Center traditional clinical laboratory assay (correlation coefficient = 0.94). This work is encouraging for the development of a rapid and accurate POC device for measuring creatinine levels in whole blood.
Gadbury, Gary L.; Allison, David B.
2012-01-01
Much has been written regarding p-values below certain thresholds (most notably 0.05) denoting statistical significance and the tendency of such p-values to be more readily publishable in peer-reviewed journals. Intuition suggests that there may be a tendency to manipulate statistical analyses to push a “near significant p-value” to a level that is considered significant. This article presents a method for detecting the presence of such manipulation (herein called “fiddling”) in a distribution of p-values from independent studies. Simulations are used to illustrate the properties of the method. The results suggest that the method has low type I error and that power approaches acceptable levels as the number of p-values being studied approaches 1000. PMID:23056287
Gadbury, Gary L; Allison, David B
2012-01-01
Much has been written regarding p-values below certain thresholds (most notably 0.05) denoting statistical significance and the tendency of such p-values to be more readily publishable in peer-reviewed journals. Intuition suggests that there may be a tendency to manipulate statistical analyses to push a "near significant p-value" to a level that is considered significant. This article presents a method for detecting the presence of such manipulation (herein called "fiddling") in a distribution of p-values from independent studies. Simulations are used to illustrate the properties of the method. The results suggest that the method has low type I error and that power approaches acceptable levels as the number of p-values being studied approaches 1000.
Lystrom, David J.
1972-01-01
Various methods of verifying real-time streamflow data are outlined in part II. Relatively large errors (those greater than 20-30 percent) can be detected readily by use of well-designed verification programs for a digital computer, and smaller errors can be detected only by discharge measurements and field observations. The capability to substitute a simulated discharge value for missing or erroneous data is incorporated in some of the verification routines described. The routines represent concepts ranging from basic statistical comparisons to complex watershed modeling and provide a selection from which real-time data users can choose a suitable level of verification.
Use of sonification in the detection of anomalous events
NASA Astrophysics Data System (ADS)
Ballora, Mark; Cole, Robert J.; Kruesi, Heidi; Greene, Herbert; Monahan, Ganesh; Hall, David L.
2012-06-01
In this paper, we describe the construction of a soundtrack that fuses stock market data with information taken from tweets. This soundtrack, or auditory display, presents the numerical and text data in such a way that anomalous events may be readily detected, even by untrained listeners. The soundtrack generation is flexible, allowing an individual listener to create a unique audio mix from the available information sources. Properly constructed, the display exploits the auditory system's sensitivities to periodicities, to dynamic changes, and to patterns. This type of display could be valuable in environments that demand high levels of situational awareness based on multiple sources of incoming information.
Enzyme-Linked Antibodies: A Laboratory Introduction to the ELISA Assay
NASA Astrophysics Data System (ADS)
Anderson, Gretchen L.; McNellis, Leo A.
1998-10-01
A fast and economical laboratory exercise is presented that qualitatively demonstrates the power of enzyme-linked antibodies to detect a specific antigen. Although ELISAs are commonly used in disease diagnosis in clinical settings, this application uses biotin, covalently attached to albumin, to take advantage of readily available reagents and avoids problems associated with potentially pathogenic antigens. The laboratory exercise is suitable for high school or freshman level biochemistry courses, and can be completed within two hours.
Readily Available Fluorescent Probe for Carbon Monoxide Imaging in Living Cells.
Feng, Weiyong; Liu, Dandan; Feng, Shumin; Feng, Guoqiang
2016-11-01
Carbon monoxide (CO) is an important gasotransmitter in living systems and its fluorescent detection is of particular interest. However, fluorescent detection of CO in living cells is still challenging due to lack of effective probes. In this paper, a readily available fluorescein-based fluorescent probe was developed for rapid detection of CO. This probe can be used to detect CO in almost wholly aqueous solution under mild conditions and shows high selectivity and sensitivity for CO with colorimetric and remarkable fluorescent turn-on signal changes. The detection limit of this probe for CO is as low as 37 nM with a linear range of 0-30 μM. More importantly, this probe (1 μM dose) can be conveniently used for fluorescent imaging CO in living cells.
Acoustic vibration test detects intermittent electrical discontinuities
NASA Technical Reports Server (NTRS)
Grieve, S. M.; Roberts, D. E.
1970-01-01
Nondestructive test method detects faulty electrical connections in inaccessible or hidden portions of electronic harness assemblies and connectors. Method employs readily available commercial equipment.
NASA Astrophysics Data System (ADS)
Mussio, P.; Gnyp, A. W.; Henshaw, P. F.
A fluctuating plume dispersion model has been developed to facilitate the prediction of odour-impact frequencies in the communities surrounding elevated point sources. The model was used to predict the frequencies of occurrence of odours of various magnitudes for 1 h periods. In addition, the model predicted the maximum odour level. The model was tested with an extensive set of data collected in the residential areas surrounding the paint shop of an automotive assembly plant. Most of the perceived odours in the vicinity of the 64, 46 m high stacks ranged between 2 and 7 odour units and generally persisted for less than 30 s. Ninety-eight different field determinations of odour impact frequencies within 1 km of the plant were conducted during the course of the study. To simplify evaluation, the frequencies of occurrence of different odour levels were summed to give the total frequency of occurrence of all readily detectable (>2 OU) odours. The model provided excellent simulation of the total frequencies of occurrence where the odour was frequent (i.e . readily detectable more than 30% of the time). At lower frequencies of occurrence the model prediction was poor. The stability class did not seem to affect the model's ability to predict field frequency values. However, the model provided excellent predictions of the maximum odour levels without being sensitive to either stability class or distance from the source. Ninety-five percent of the predicted maximum values were within a factor of two of the measured field maximum values.
High throughput protein production screening
Beernink, Peter T [Walnut Creek, CA; Coleman, Matthew A [Oakland, CA; Segelke, Brent W [San Ramon, CA
2009-09-08
Methods, compositions, and kits for the cell-free production and analysis of proteins are provided. The invention allows for the production of proteins from prokaryotic sequences or eukaryotic sequences, including human cDNAs using PCR and IVT methods and detecting the proteins through fluorescence or immunoblot techniques. This invention can be used to identify optimized PCR and WT conditions, codon usages and mutations. The methods are readily automated and can be used for high throughput analysis of protein expression levels, interactions, and functional states.
Wannet, W J; Hermans, J H; van Der Drift, C; Op Den Camp, H J
2000-02-01
A convenient and sensitive method was developed to separate and detect various types of carbohydrates (polyols, mono- and disaccharides, and phosphorylated sugars) simultaneously using high-performance liquid chromatography (HPLC). The method consists of a chromatographic separation on a CarboPac PA1 anion-exchange analytical column followed by pulsed amperometric detection. In a single run (43 min) 13 carbohydrates were readily resolved. Calibration plots were linear over the ranges of 5-25 microM to 1. 0-1.5 mM. The reliable and fast analysis technique, avoiding derivatization steps and long run times, was used to determine the levels of carbohydrates involved in mannitol and trehalose metabolism in the edible mushroom Agaricus bisporus. Moreover, the method was used to study the trehalose phosphorylase reaction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Madhavi Z; Stewart, Arthur J; Gwinn, Dr. Kimberley
Laser-induced breakdown spectroscopy was used to determine the impact of endophyte (Neotyphodium sp.) infection on elemental composition of tall fescue (Festuca arundinacea). Leaf material from endophyte-infected (E+) and endophyte-free (E-) tall fescue populations in established plots was examined. Leaf-tissue digestates were also tested for metals, by ICP-MS. Seven of eleven metals (Ca, Mg, Fe, Mn, Cu, Ni and Zn) were measured by both techniques at concentrations great enough to reliably compare. Mg, Zn, and Cd, a toxic metal that can be present in forage, were readily detected by LIBS, even though Cd concentrations in the plants were below levels typicallymore » achieved using ICP-MS detection. Implications of these results for research on forage analysis and phytoremediation are discussed.« less
Detectability of CO2 Flux Signals by a Space-Based Lidar Mission
NASA Technical Reports Server (NTRS)
Hammerling, Dorit M.; Kawa, S. Randolph; Schaefer, Kevin; Doney, Scott; Michalak, Anna M.
2015-01-01
Satellite observations of carbon dioxide (CO2) offer novel and distinctive opportunities for improving our quantitative understanding of the carbon cycle. Prospective observations include those from space-based lidar such as the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. Here we explore the ability of such a mission to detect regional changes in CO2 fluxes. We investigate these using three prototypical case studies, namely the thawing of permafrost in the Northern High Latitudes, the shifting of fossil fuel emissions from Europe to China, and changes in the source-sink characteristics of the Southern Ocean. These three scenarios were used to design signal detection studies to investigate the ability to detect the unfolding of these scenarios compared to a baseline scenario. Results indicate that the ASCENDS mission could detect the types of signals investigated in this study, with the caveat that the study is based on some simplifying assumptions. The permafrost thawing flux perturbation is readily detectable at a high level of significance. The fossil fuel emission detectability is directly related to the strength of the signal and the level of measurement noise. For a nominal (lower) fossil fuel emission signal, only the idealized noise-free instrument test case produces a clearly detectable signal, while experiments with more realistic noise levels capture the signal only in the higher (exaggerated) signal case. For the Southern Ocean scenario, differences due to the natural variability in the ENSO climatic mode are primarily detectable as a zonal increase.
Passage of irinotecan and its active metabolite, SN-38, into human milk.
Nakagawa, J; Terui, K; Hosoi, K; Ueno, K; Yokoyama, Y; Hayakari, M
2016-10-01
We measured the levels of irinotecan and its active metabolite, SN-38, in human milk after the administration of irinotecan to assess the potential risks when women treated with irinotecan nurse their infants. Human milk was collected for 6 days starting on the day after irinotecan was administered. The levels of irinotecan and SN-38 in human milk were measured using liquid chromatography-mass spectrometry. Irinotecan was detected on Days 2 and 3 but not after Day 4. A strong signal indicating the presence of SN-38 was detected on Day 2 and the signal was readily detected until Day 7, indicating that SN-38 remained in human milk. Intravenously administered CPT-11 continues to pass into human milk over a prolonged period in the form of its active metabolite, SN-38. The relationship between administration of CPT-11 and SN-38 exposure and toxicity is still not well defined, so patients should avoid nursing their infants while they are being treated with CPT-11. © 2016 John Wiley & Sons Ltd.
Evaluation of a hygiene monitor for detection of contamination in dental surgeries.
Douglas, C W; Rothwell, P S
1991-05-11
Routines for disinfecting working surfaces in dental surgeries are difficult to monitor without time-consuming and labour-intensive microbiological techniques, yet effective monitoring is a vital part of cross-infection control. Easy to use, on-site methods would be valuable in this context. This study evaluates a portable monitor, the Biotrace Hygiene Monitor, which uses bioluminescence to measure adenosine triphosphate (ATP) on surfaces. Under laboratory conditions, the ability of the monitor to detect whole saliva and Streptococcus sanguis was determined and, in the general practice environment, the level of ATP on surfaces in five dental surgeries was assessed. The minimum amount of saliva detectable was 0.5 microliters and in surgeries, the monitor readily identified numerous surfaces with fairly high levels of ATP. Routine cleaning methods sometimes left ATP on surfaces at levels which represented a cross-infection risk, if it is assumed that the ATP derived from patients' saliva. Modification of cleaning methods resulted in a reduction of ATP levels to within that which could be considered reasonably practicably safe. It is concluded that the Biotrace Hygiene Monitor offers a simple and valuable means of monitoring dental practice cleaning routines.
Method for phosphorothioate antisense DNA sequencing by capillary electrophoresis with UV detection.
Froim, D; Hopkins, C E; Belenky, A; Cohen, A S
1997-11-01
The progress of antisense DNA therapy demands development of reliable and convenient methods for sequencing short single-stranded oligonucleotides. A method of phosphorothioate antisense DNA sequencing analysis using UV detection coupled to capillary electrophoresis (CE) has been developed based on a modified chain termination sequencing method. The proposed method reduces the sequencing cost since it uses affordable CE-UV instrumentation and requires no labeling with minimal sample processing before analysis. Cycle sequencing with ThermoSequenase generates quantities of sequencing products that are readily detectable by UV. Discrimination of undesired components from sequencing products in the reaction mixture, previously accomplished by fluorescent or radioactive labeling, is now achieved by bringing concentrations of undesired components below the UV detection range which yields a 'clean', well defined sequence. UV detection coupled with CE offers additional conveniences for sequencing since it can be accomplished with commercially available CE-UV equipment and is readily amenable to automation.
Method for phosphorothioate antisense DNA sequencing by capillary electrophoresis with UV detection.
Froim, D; Hopkins, C E; Belenky, A; Cohen, A S
1997-01-01
The progress of antisense DNA therapy demands development of reliable and convenient methods for sequencing short single-stranded oligonucleotides. A method of phosphorothioate antisense DNA sequencing analysis using UV detection coupled to capillary electrophoresis (CE) has been developed based on a modified chain termination sequencing method. The proposed method reduces the sequencing cost since it uses affordable CE-UV instrumentation and requires no labeling with minimal sample processing before analysis. Cycle sequencing with ThermoSequenase generates quantities of sequencing products that are readily detectable by UV. Discrimination of undesired components from sequencing products in the reaction mixture, previously accomplished by fluorescent or radioactive labeling, is now achieved by bringing concentrations of undesired components below the UV detection range which yields a 'clean', well defined sequence. UV detection coupled with CE offers additional conveniences for sequencing since it can be accomplished with commercially available CE-UV equipment and is readily amenable to automation. PMID:9336449
Amantonico, Andrea; Urban, Pawel L; Fagerer, Stephan R; Balabin, Roman M; Zenobi, Renato
2010-09-01
Heterogeneity is a characteristic feature of all populations of living organisms. Here we make an attempt to validate a single-cell mass spectrometric method for detection of changes in metabolite levels occurring in populations of unicellular organisms. Selected metabolites involved in central metabolism (ADP, ATP, GTP, and UDP-Glucose) could readily be detected in single cells of Closterium acerosum by means of negative-mode matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS). The analytical capabilities of this approach were characterized using standard compounds. The method was then used to study populations of individual cells with different levels of the chosen metabolites. With principal component analysis and support vector machine algorithms, it was possible to achieve a clear separation of individual C. acerosum cells in different metabolic states. This study demonstrates the suitability of mass spectrometric analysis of metabolites in single cells to measure cell-population heterogeneity.
Harvesting wind energy to detect weak signals using mechanical stochastic resonance.
Breen, Barbara J; Rix, Jillian G; Ross, Samuel J; Yu, Yue; Lindner, John F; Mathewson, Nathan; Wainwright, Elliot R; Wilson, Ian
2016-12-01
Wind is free and ubiquitous and can be harnessed in multiple ways. We demonstrate mechanical stochastic resonance in a tabletop experiment in which wind energy is harvested to amplify weak periodic signals detected via the movement of an inverted pendulum. Unlike earlier mechanical stochastic resonance experiments, where noise was added via electrically driven vibrations, our broad-spectrum noise source is a single flapping flag. The regime of the experiment is readily accessible, with wind speeds ∼20 m/s and signal frequencies ∼1 Hz. We readily obtain signal-to-noise ratios on the order of 10 dB.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Madhavi Z.; Stewart, Arthur J.; Gwinn, Kimberley D.
Laser-induced breakdown spectroscopy (LIBS) was used to determine the impact of endophyte (Neotyphodium sp.) infection on elemental composition of tall fescue (Festuca arundinacea). Leaf material from endophyte-infected (E+) and endophyte-free (E-) tall fescue populations in established plots was examined. Leaf-tissue digestates were also tested for metals, by inductively coupled plasma (ICP) mass spectrometry (MS). Seven of eleven metals (Ca, Mg, Fe, Mn, Cu, Ni, and Zn) were measured by both techniques at concentrations great enough for a reliable comparison. Mg, Zn, and Cd, a toxic metal that can be present in forage, were readily detected by LIBS, even though Cdmore » concentrations in the plants were below levels typically achieved using ICP MS detection. Implications of these results for research on forage analysis and phytoremediation are discussed.« less
Kaddi, Chanchala D.; Bennett, Rachel V.; Paine, Martin R. L.; Banks, Mitchel D.; Weber, Arthur L.; Fernández, Facundo M.; Wang, May D.
2016-01-01
Full characterization of complex reaction mixtures is necessary to understand mechanisms, optimize yields, and elucidate secondary reaction pathways. Molecular-level information for species in such mixtures can be readily obtained by coupling mass spectrometry imaging (MSI) with thin layer chromatography (TLC) separations. User-guided investigation of imaging data for mixture components with known m/z values is generally straightforward; however, spot detection for unknowns is highly tedious, and limits the applicability of MSI in conjunction with TLC. To accelerate imaging data mining, we developed DetectTLC, an approach that automatically identifies m/z values exhibiting TLC spot-like regions in MS molecular images. Furthermore, DetectTLC can also spatially match m/z values for spots acquired during alternating high and low collision-energy scans, pairing product ions with precursors to enhance structural identification. As an example, DetectTLC is applied to the identification and structural confirmation of unknown, yet significant, products of abiotic pyrazinone and aminopyrazine nucleoside analog synthesis. PMID:26508443
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Seema; Simpson, David C.; Tolic, Nikola
We investigated the combination of weak anion exchange (WAX) fractionation and on-line reversed phase liquid chromatography (RPLC) separation using a 12 T FTICR mass spectrometer for the detection of intact proteins from a Shewanella oneidensis MR-1 cell lysate. 715 intact proteins were detected and the combined results from the WAX fractions and the unfractionated cell lysate were aligned using LC-MS features to facilitate protein abundance measurements. Protein identifications and post translational modifications were assigned for ~10% of the detected proteins by comparing intact protein mass measurements to proteins identified in peptide MS/MS analysis of an aliquot of the same fraction.more » Intact proteins were also detected for S. oneidensis lysates obtained from cells grown on 13C, 15N depleted media under aerobic and sub-oxic conditions. This work aimed at optimizing intact protein detection for profiling proteins at a level that incorporates their modification complement. The strategy can be readily applied for measuring differential protein abundances, and provides a platform for high-throughput selection of biologically relevant targets for further characterization.« less
Natural gas odor level testing: Instruments and applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberson, E.H.
1995-12-01
An odor in natural and LP gases is necessary. The statistics are overwhelming; when gas customers can smell a leak before the percentage of gas in air reaches a combustible mixture, the chances of an accident are greatly reduced. How do gas companies determine if there is sufficient odor reaching every gas customers home? Injection equipment is important. The rate and quality of odorant is important. Nevertheless, precision odorization alone does not guarantee that customers` homes always have gas with a readily detectable odor. To secure that goal, odor monitoring instruments are necessary.
Formation of mutagens in cooked foods. I. Beef.
Spingarn, N E; Weisburger, J H
1979-09-01
Mutagens detectable by Salmonella typhimurium TA98, after activation by liver S-9 fraction, are formed when meat is cooked by frying, broiling and boiling. High levels of mutagenic activity are formed rapidly when frying, or more slowly during broiling. Formation of mutagens in boiled beef stock requires several days under reflux, but shows a strong concentration dependence. Time curves suggest that a period exists during which mutagens are not readily formed; however, after this period mutagen production is rapid. Hamburgers from commercial franchises were frequently mutagenically active.
Rapid Detection of Visually Provocative Animals by Preschool Children and Adults
ERIC Educational Resources Information Center
Penkunas, Michael J.; Coss, Richard G.
2013-01-01
The ability to detect dangerous animals rapidly in complex landscapes has been historically important during human evolution. Previous research has shown that snake images are more readily detected than images of benign animals. To provide a stringent test of superior snake detection in preschool children and adults, Experiment 1 consisted of two…
Single-Cell Detection of Secreted Aβ and sAPPα from Human IPSC-Derived Neurons and Astrocytes.
Liao, Mei-Chen; Muratore, Christina R; Gierahn, Todd M; Sullivan, Sarah E; Srikanth, Priya; De Jager, Philip L; Love, J Christopher; Young-Pearse, Tracy L
2016-02-03
Secreted factors play a central role in normal and pathological processes in every tissue in the body. The brain is composed of a highly complex milieu of different cell types and few methods exist that can identify which individual cells in a complex mixture are secreting specific analytes. By identifying which cells are responsible, we can better understand neural physiology and pathophysiology, more readily identify the underlying pathways responsible for analyte production, and ultimately use this information to guide the development of novel therapeutic strategies that target the cell types of relevance. We present here a method for detecting analytes secreted from single human induced pluripotent stem cell (iPSC)-derived neural cells and have applied the method to measure amyloid β (Aβ) and soluble amyloid precursor protein-alpha (sAPPα), analytes central to Alzheimer's disease pathogenesis. Through these studies, we have uncovered the dynamic range of secretion profiles of these analytes from single iPSC-derived neuronal and glial cells and have molecularly characterized subpopulations of these cells through immunostaining and gene expression analyses. In examining Aβ and sAPPα secretion from single cells, we were able to identify previously unappreciated complexities in the biology of APP cleavage that could not otherwise have been found by studying averaged responses over pools of cells. This technique can be readily adapted to the detection of other analytes secreted by neural cells, which would have the potential to open new perspectives into human CNS development and dysfunction. We have established a technology that, for the first time, detects secreted analytes from single human neurons and astrocytes. We examine secretion of the Alzheimer's disease-relevant factors amyloid β (Aβ) and soluble amyloid precursor protein-alpha (sAPPα) and present novel findings that could not have been observed without a single-cell analytical platform. First, we identify a previously unappreciated subpopulation that secretes high levels of Aβ in the absence of detectable sAPPα. Further, we show that multiple cell types secrete high levels of Aβ and sAPPα, but cells expressing GABAergic neuronal markers are overrepresented. Finally, we show that astrocytes are competent to secrete high levels of Aβ and therefore may be a significant contributor to Aβ accumulation in the brain. Copyright © 2016 the authors 0270-6474/16/361730-17$15.00/0.
Mellerup, Anders; Ståhl, Marie
2015-01-01
The aim of this article was to define the sampling level and method combination that captures antibiotic resistance at pig herd level utilizing qPCR antibiotic resistance gene quantification and culture-based quantification of antibiotic resistant coliform indicator bacteria. Fourteen qPCR assays for commonly detected antibiotic resistance genes were developed, and used to quantify antibiotic resistance genes in total DNA from swine fecal samples that were obtained using different sampling and pooling methods. In parallel, the number of antibiotic resistant coliform indicator bacteria was determined in the same swine fecal samples. The results showed that the qPCR assays were capable of detecting differences in antibiotic resistance levels in individual animals that the coliform bacteria colony forming units (CFU) could not. Also, the qPCR assays more accurately quantified antibiotic resistance genes when comparing individual sampling and pooling methods. qPCR on pooled samples was found to be a good representative for the general resistance level in a pig herd compared to the coliform CFU counts. It had significantly reduced relative standard deviations compared to coliform CFU counts in the same samples, and therefore differences in antibiotic resistance levels between samples were more readily detected. To our knowledge, this is the first study to describe sampling and pooling methods for qPCR quantification of antibiotic resistance genes in total DNA extracted from swine feces. PMID:26114765
ERIC Educational Resources Information Center
Foster, John; And Others
1986-01-01
Presents a set of laboratory experiments that can assist students in the detection of carbon dioxide. Offers a variation of the supported drop method of carbon dioxide detection that provides readily visible positive results. Includes background information on carbon dioxide. (ML)
Thermo-Reflectance Spectra of Eros: Unambiguous Detection of Olivine
NASA Technical Reports Server (NTRS)
Lucey, P. G.; Hinrichs, J. L.; Urquhart-Kelly, M.; Wellnitz, D.; Bell, J. F., III; Clark, B. E.
2001-01-01
Olivine is readily detected on 433 Eros using the new thermo-reflectance spectral technique applied to near-IR spectra obtained at Eros by the NEAR spacecraft. Additional information is contained in the original extended abstract.
Sensor/amplifier for weak light sources
NASA Technical Reports Server (NTRS)
Desmet, D. J.; Jason, A. J.; Parr, A. C.
1980-01-01
Light sensor/amplifier circuit detects weak light converts it into strong electrical signal in electrically noisy environment. Circuit is relatively simple and uses inexpensive, readily available components. Device is useful in such applications as fire detection and photographic processing.
A microfluidic approach for hemoglobin detection in whole blood
NASA Astrophysics Data System (ADS)
Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.
2017-10-01
Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.
Monitoring/Verification using DMS: TATP Example
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stephan Weeks, Kevin Kyle, Manuel Manard
Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations-management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a “smart dust” sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biologicalmore » materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. Fast GC is the leading field analytical method for gas phase separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15–300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements.« less
Monitoring/Verification Using DMS: TATP Example
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Kyle; Stephan Weeks
Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operationsmanagement systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a “smart dust” sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biologicalmore » materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. GC is the leading analytical method for the separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15–300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements.« less
2015-01-01
This study quantitatively measured neonicotinoids in various foods that are common to human consumption. All fruit and vegetable samples (except nectarine and tomato) and 90% of honey samples were detected positive for at least one neonicotinoid; 72% of fruits, 45% of vegetables, and 50% of honey samples contained at least two different neonicotinoids in one sample, with imidacloprid having the highest detection rate among all samples. All pollen samples from New Zealand contained multiple neonicotinoids, and five of seven pollens from Massachusetts detected positive for imidacloprid. These results show the prevalence of low-level neonicotinoid residues in fruits, vegetables, and honey that are readily available in the market for human consumption and in the environment where honeybees forage. In light of new reports of toxicological effects in mammals, the results strengthen the importance of assessing dietary neonicotinoid intakes and the potential human health effects. PMID:24933495
Chen, Mei; Tao, Lin; McLean, John; Lu, Chensheng
2014-07-02
This study quantitatively measured neonicotinoids in various foods that are common to human consumption. All fruit and vegetable samples (except nectarine and tomato) and 90% of honey samples were detected positive for at least one neonicotinoid; 72% of fruits, 45% of vegetables, and 50% of honey samples contained at least two different neonicotinoids in one sample, with imidacloprid having the highest detection rate among all samples. All pollen samples from New Zealand contained multiple neonicotinoids, and five of seven pollens from Massachusetts detected positive for imidacloprid. These results show the prevalence of low-level neonicotinoid residues in fruits, vegetables, and honey that are readily available in the market for human consumption and in the environment where honeybees forage. In light of new reports of toxicological effects in mammals, the results strengthen the importance of assessing dietary neonicotinoid intakes and the potential human health effects.
Kertesz, Vilmos; Calligaris, David; Feldman, Daniel R.; ...
2015-06-18
Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections using a fully automated droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system for spatially resolved sampling, HPLC separation, and mass spectral detection. Excellent correlation was found between the protein distribution data obtained with this droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system and those data obtained with matrix assisted laser desorption ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland.more » AVP was most abundant in the posterior pituitary gland region (neurohypophysis) and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH secreting adenomas and in normal anterior adenohypophysis compared to non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis as anticipated. This work demonstrates that a fully automated droplet-based liquid microjunction surface sampling system coupled to HPLC-ESI-MS/MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, such as AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity and specificity of the current methodology support the potential of this basic technology with further advancement for assisting surgical decision-making.« less
Kertesz, Vilmos; Calligaris, David; Feldman, Daniel R; Changelian, Armen; Laws, Edward R; Santagata, Sandro; Agar, Nathalie Y R; Van Berkel, Gary J
2015-08-01
Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections, using a fully automated droplet-based liquid-microjunction surface-sampling-HPLC-ESI-MS-MS system for spatially resolved sampling, HPLC separation, and mass spectrometric detection. Excellent correlation was found between the protein distribution data obtained with this method and data obtained with matrix-assisted laser desorption/ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland. AVP was most abundant in the posterior pituitary gland region (neurohypophysis), and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH-secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH-secreting adenomas and in normal anterior adenohypophysis compared with non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis, as expected. This work reveals that a fully automated droplet-based liquid-microjunction surface-sampling system coupled to HPLC-ESI-MS-MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, including AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity, and specificity of this method support the potential of this basic technology, with further advancement, for assisting surgical decision-making. Graphical Abstract Mass spectrometry based profiling of hormones in human pituitary gland and tumor thin tissue sections.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kertesz, Vilmos; Calligaris, David; Feldman, Daniel R.
Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections using a fully automated droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system for spatially resolved sampling, HPLC separation, and mass spectral detection. Excellent correlation was found between the protein distribution data obtained with this droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system and those data obtained with matrix assisted laser desorption ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland.more » AVP was most abundant in the posterior pituitary gland region (neurohypophysis) and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH secreting adenomas and in normal anterior adenohypophysis compared to non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis as anticipated. This work demonstrates that a fully automated droplet-based liquid microjunction surface sampling system coupled to HPLC-ESI-MS/MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, such as AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity and specificity of the current methodology support the potential of this basic technology with further advancement for assisting surgical decision-making.« less
Picture Detection in Rapid Serial Visual Presentation: Features or Identity?
ERIC Educational Resources Information Center
Potter, Mary C.; Wyble, Brad; Pandav, Rijuta; Olejarczyk, Jennifer
2010-01-01
A pictured object can be readily detected in a rapid serial visual presentation sequence when the target is specified by a superordinate category name such as "animal" or "vehicle". Are category features the initial basis for detection, with identification of the specific object occurring in a second stage (Evans &…
An aptamer nanopore-enabled microsensor for detection of theophylline.
Feng, Silu; Chen, Changtian; Wang, Wei; Que, Long
2018-05-15
This paper reports an aptamer-based nanopore thin film sensor for detecting theophylline in the buffer solution and complex fluids including plant extracts and serum samples. Compared to antibody-based detection, aptamer-based detection offers many advantages such as low cost and high stability at elevated temperatures. Experiments found that this type of sensor can readily detect theophylline at a concentration as low as 0.05µM, which is much lower than the detection limit of current lab-based equipment such as liquid chromatography (LC). Experiments also found that the aptamer-based sensor has good specificity, selectivity, and reasonable reusability with a significantly improved dynamic detection range. By using the same nanopore thin film sensors as the reference sensors to further mitigate the non-specific binding effect, the theophylline in plant extracts and serum has been detected. Only a small amount (~1μL) of plant extracts or serum samples is required to measure theophylline. Its low cost and ease-of-operation make this type of sensor suitable for point-of-care application to monitor the theophylline level of patients in real time. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhao, Baoying; Yang, Binsheng; Hu, Xiangquan; Liu, Bin
2018-06-01
Aggregation-induced emission (AIE) active fluorescent probes have attracted great potential in biological sensors. In this paper two cyanostilbene based fluorescence chemoprobe Cya-NO2 (1) and Cya-N3 (2) were developed and evaluated for the selective and sensitive detection of hydrogen sulfide (H2S). Both of these probes behave aggression-induced emission (AIE) activity which fluoresces in the red region with a large Stokes shift. They exhibit rapid response to H2S with enormous colorimetric and ratiometric fluorescent changes. They are readily employed for assessing intracellular H2S levels.
Reagan, Adrian C; Mallinson, Paul I; O'Connell, Timothy; McLaughlin, Patrick D; Krauss, Bernhard; Munk, Peter L; Nicolaou, Savvas; Ouellette, Hugue A
2014-01-01
Computed tomography (CT) is often used to assess the presence of occult fractures when plain radiographs are equivocal in the acute traumatic setting. While providing increased spatial resolution, conventional computed tomography is limited in the assessment of bone marrow edema, a finding that is readily detectable on magnetic resonance imaging (MRI).Dual-energy CT has recently been shown to demonstrate patterns of bone marrow edema similar to corresponding MRI studies. Dual-energy CT may therefore provide a convenient modality for further characterizing acute bony injury when MRI is not readily available. We report our initial experiences of 4 cases with imaging and clinical correlation.
Ultrasensitive optical detection of trinitrotoluene by ethylenediamine-capped gold nanoparticles.
Lin, Dongyue; Liu, Honglin; Qian, Kai; Zhou, Xia; Yang, Liangbao; Liu, Jinhuai
2012-09-26
This study found that 1,2-ethylenediamine (EDA) as a primary amine could be modified onto the surface of citrate-stabilized gold nanoparticles (Au NPs), and the EDA-capped Au NPs were successfully used as an ultrasensitive optical probe for TNT detection. The strong donor-acceptor (D-A) interactions between EDA and trinitrotoluene (TNT) at the Au NP/solution interface induced significant aggregation of the EDA-capped Au NPs, and enabled to easily realize the direct colorimetric detection of ultratrace TNT. The results showed that such a color change was readily seen by the naked eye, and the colorimetric detection could be down to 400 pM level of TNT with excellent discrimination against other nitro compounds. UV-vis absorption spectroscopy was used to examine the TNT-induced changes in local surface plasmon resonance (LSPR) of EDA-capped Au NPs, and a new LSPR band at ca. 630 nm arose along with the addition of TNT, which produced a detection limit of TNT down to ca. 40 pM. Furthermore, dynamic light scattering measurements evidenced the ultratrace TNT-induced small changes in the size of the EDA-capped Au NPs, and realized the quick and accurate detection of TNT in 0.4 pM level. These results demonstrated the ultrahigh sensitivity of this optical probe for TNT detection. Moreover, this optical probe is sample, stable, low-cost, and these excellent properties make it quite promising for infield and rapid detection of TNT. Copyright © 2012 Elsevier B.V. All rights reserved.
Detection of Mannitol Formation by Bacteria
Chalfan, Y.; Levy, R.; Mateles, R. I.
1975-01-01
A test is described by means of which formation of mannitol from fructose by lactic acid bacteria can be readily detected. The test is based on removal of interference of residual fructose by dehydration with hydrochloric acid followed by thin-layer chromatography. PMID:1101827
Simultaneous S- and X-band uplink-downlink performance at DSS 13
NASA Technical Reports Server (NTRS)
Freiley, A. J.
1988-01-01
The Deep Space Station 13 26-meter antenna with the second generation S/X feedcone was tested to determine the dual S- and X-band (2.1 to 2.3 GHz and 7.1 to 8.5 GHz) transmit and receive performance. Measurements were conducted using the 20 kW transmitters at S- and X-band while simultaneously receiving S- and X-band. This system proved to be very quiet compared with the other DSN antennas. Under normal tracking configurations, no noise burst or intermodulation product (IMP) activity was detectable to the -175 dBm level. To prove the instrumentation's ability to detect such phenomena, an IMP generator was introduced onto the system with positive, verifiable results. The IMP occurred at the -162 dBm level, accompanied by moderate noise burst activity, and was readily repeatable. The measurement also showed the possible need for additional fourth channel filtering in the system to reduce the effect of the transmitter power on the low noise amplifiers.
Ferguson, Stephen A; Wang, Xuewei; Meyerhoff, Mark E
2016-08-07
Polymeric quaternary ammonium salts (polyquaterniums) have found increasing use in industrial and cosmetic applications in recent years. More specifically, polyquaternium-10 (PQ-10) is routinely used in cosmetic applications as a conditioner in personal care product formulations. Herein, we demonstrate the use of potentiometric polyion-sensitive polymeric membrane-based electrodes to quantify PQ-10 levels. Mixtures containing both PQ-10 and sodium lauryl sulfate (SLS) are used as model samples to illustrate this new method. SLS is often present in cosmetic samples that contain PQ-10 (e.g., shampoos, etc.) and this surfactant species interferes with the polyion sensor detection chemistry. However, it is shown here that SLS can be readily separated from the PQ-10/SLS mixture by use of an anion-exchange resin and that the PQ-10 can then be titrated with dextran sulphate (DS). This titration is monitored by potentiometric polyanion sensors to provide equivalence points that are directly proportional to PQ-10 concentrations.
Aflatoxin variability in pistachios.
Mahoney, N E; Rodriguez, S B
1996-01-01
Pistachio fruit components, including hulls (mesocarps and epicarps), seed coats (testas), and kernels (seeds), all contribute to variable aflatoxin content in pistachios. Fresh pistachio kernels were individually inoculated with Aspergillus flavus and incubated 7 or 10 days. Hulled, shelled kernels were either left intact or wounded prior to inoculation. Wounded kernels, with or without the seed coat, were readily colonized by A. flavus and after 10 days of incubation contained 37 times more aflatoxin than similarly treated unwounded kernels. The aflatoxin levels in the individual wounded pistachios were highly variable. Neither fungal colonization nor aflatoxin was detected in intact kernels without seed coats. Intact kernels with seed coats had limited fungal colonization and low aflatoxin concentrations compared with their wounded counterparts. Despite substantial fungal colonization of wounded hulls, aflatoxin was not detected in hulls. Aflatoxin levels were significantly lower in wounded kernels with hulls than in kernels of hulled pistachios. Both the seed coat and a water-soluble extract of hulls suppressed aflatoxin production by A. flavus. PMID:8919781
NASA Astrophysics Data System (ADS)
Jiang, Hao
A method is developed for modeling, detecting, and locating material damage in homogeneous thin metallic sheets and sandwich panels. Analytical and numerical models are used along with non-contact, passive acoustic transmission measurements. It is shown that global and local damage mechanisms characterized by both material and geometrical changes in structural components can be detected using passive acoustic transmission measurements. Theoretical models of a flat sheet and sandwich panel are developed to describe the effects of global material damage due to density, modulus, or thickness changes on backplane radiated sound pressure level distributions. To describe the effects of local material damage, a three-segment stepped beam model and finite element beam, plate, and sandwich panel models are developed and analyzed using the acoustic transmission approach. It is shown that increases or decreases in transmitted sound energy occur behind a damaged material component that exhibits changes in thickness or other geometric or material properties. The damage due to thickness and density changes can be detected from the acoustic transmission, but modulus changes cannot. If the damage is located at an anti-node of a certain forced vibration pattern, the damage can be more readily observed in the data. Higher excitation frequencies within the operating spectrum are preferred to lower frequencies for damage detection. With the finite element beam, plate, and sandwich panel models, local damage detection has been performed in simulations. Experiments on a baffled homogeneous sheet and sandwich panel subjected to broadband acoustic energy show that transmitted intensity measurements with non-contact probes can be used to identify and locate material defects in the sheet and sandwich panel. Material damage is most readily identified where the changes in transmitted sound intensity are largest in the resonant frequency range of the panel. The three main contributions of this research are: (1) the use of non-contact sensing to detect global and localized damage in structural components; (2) the analytical and numerical modeling of material and geometrical damage mechanisms in structural components; and, (3) the experimental verification of acoustic transmission measurements for detecting both material and geometric damage mechanisms.
Kang, Mijeong; Kim, Eunkyoung; Winkler, Thomas E; Banis, George; Liu, Yi; Kitchen, Christopher A; Kelly, Deanna L; Ghodssi, Reza; Payne, Gregory F
2017-09-15
Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia. Copyright © 2017 Elsevier B.V. All rights reserved.
Cody, Robert B; Tamura, Jun; Downard, Kevin M
2018-01-01
The ability to rapidly identify and quantitate, over a wide range of concentrations, anthocyanins in food and therapeutic products is important to ensuring their presence at medicinally significant levels. Sensitive, yet mild, analysis conditions are required given their susceptibility to degradation and transformation. Paper spray ionization has been used to detect and quantify the levels of anthocyanin levels in extracts of fresh and dried elderberries, and elderberry stems, as well as 3 commercially available nutraceutical formulations. The component cyanidin glucosides, including cyanidin-3-sambubioside, cyanidin-3-glucoside, cyanidin-3,5-diglucoside, cyanidin-3-sambubioside-5-glucoside, and the aglycone cyanidin, were readily detected in a range of sources. Quantitation was achieved by establishing a calibration plot from dilutions of a stock solution of cyanidin-3,5-diglucoside containing malvidin-3,5-diglucoside as an internal standard at a fixed concentration. The same standard was used to quantify the anthocyanin content in the fruit and nutraceutical formulations. Wide 5-fold variations in anthocyanin concentration were detected in the nutraceutical formulations from different suppliers ranging from 1050 to 5430 mg/100 g. These concentrations compared with 500 to 2370 mg/100 g measured in the dried stems and fruit, respectively. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Athale, R.; Lee, S. H.
1976-01-01
Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.
Lau, Lily; Basso, Michael R; Estevis, Eduardo; Miller, Ashley; Whiteside, Douglas M; Combs, Dennis; Arentsen, Timothy J
2017-11-01
Performance validity tests (PVTs) and symptom validity tests (SVTs) are often administered during neuropsychological evaluations. Examinees may be coached to avoid detection by measures of response validity. Relatively little research has evaluated whether graduated levels of coaching has differential effects upon PVT and SVT performance. Accordingly, the present experiment evaluated the effect of graduated levels of coaching upon the classification accuracy of commonly used PVTs and SVTs and the currently accepted criterion of failing two or more PVTs or SVTs. Participants simulated symptoms associated with mild traumatic brain injury (TBI). One group was provided superficial information concerning cognitive, emotional, and physical symptoms. Another group was provided detailed information about such symptoms. A third group was provided detailed information about symptoms and guidance how to evade detection by PVTs. These groups were compared to an honest-responding group. Extending prior experiments, stand-alone and embedded PVT measures were administered in addition to SVTs. The three simulator groups were readily identified by PVTs and SVTs, but a meaningful minority of those provided test-taking strategies eluded detection. The Word Memory Test emerged as the most sensitive indicator of simulated mild TBI symptoms. PVTs achieved more sensitive detection of simulated head injury status than SVTs. Individuals coached to modify test-taking performance were marginally more successful in eluding detection by PVTs and SVTs than those coached with respect to TBI symptoms only. When the criterion of failing two or more PVTs or SVTs was applied, only 5% eluded detection.
NASA Technical Reports Server (NTRS)
Thompson, J. L.; Vijayan, K.; Riley, D. A.
2000-01-01
We have developed a method of fixing, embedding, sectioning, and staining that allows high-resolution detection of myofibrillar structure and myosin immunocytochemical muscle fiber typing in serial semithin sections of LR White plastic embedded muscle at the light microscopic level. Traditional approaches, such as cryostat sections, permit fiber typing, but small myofibrillar lesions (1-3 sarcomeres) are difficult to detect because of section thickness. Semithin sections of hydrophobic resins do not stain well either histochemically or immunocytochemically. Electron microscopy can resolve lesions and discriminate fiber types based on morphology, but the sampling area is small. Our goal was to develop a rapid method for defining both fiber type and high-resolution primary myofibrillar lesion damage. Mild fixation (1-4% paraformaldehyde, 0. 05-0.1% glutaraldehyde) and embedment in a hydrophilic resin (LR White) were used. Myofibrillar structure was extremely well preserved at the light microscopic (LM) level, and lesions could be readily resolved in Toluidine blue stained 500-nm sections. Fiber type was defined by LM immunomyosin staining of serial plastic semithin sections, which demonstrated reciprocal staining patterns for "fast (Sigma M4276) and "total" (skeletal muscle) myosins (Sigma M7523). Copyright 2000 Wiley-Liss, Inc.
Code of Federal Regulations, 2013 CFR
2013-07-01
... composed letter 165 5 Information and assistance that re- quires significant file search or retrieval of...) Level 1 includes the provision of basic information from readily available data that does not require... includes the provision of information from readily available data that requires minimal technical...
Code of Federal Regulations, 2011 CFR
2011-07-01
... composed letter 165 5 Information and assistance that re- quires significant file search or retrieval of...) Level 1 includes the provision of basic information from readily available data that does not require... includes the provision of information from readily available data that requires minimal technical...
Code of Federal Regulations, 2014 CFR
2014-07-01
... composed letter 165 5 Information and assistance that re- quires significant file search or retrieval of...) Level 1 includes the provision of basic information from readily available data that does not require... includes the provision of information from readily available data that requires minimal technical...
Code of Federal Regulations, 2012 CFR
2012-07-01
... composed letter 165 5 Information and assistance that re- quires significant file search or retrieval of...) Level 1 includes the provision of basic information from readily available data that does not require... includes the provision of information from readily available data that requires minimal technical...
Code of Federal Regulations, 2010 CFR
2010-07-01
... composed letter 165 5 Information and assistance that re- quires significant file search or retrieval of...) Level 1 includes the provision of basic information from readily available data that does not require... includes the provision of information from readily available data that requires minimal technical...
Monitoring/Verification using DMS: TATP Example
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stephan Weeks; Kevin Kyle
Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a 'smart dust' sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the use of explosives or chemical and biologicalmore » weapons in terrorist activities. Two peroxide-based liquid explosives, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD), are synthesized from common chemicals such as hydrogen peroxide, acetone, sulfuric acid, ammonia, and citric acid (Figure 1). Recipes can be readily found on the Internet by anyone seeking to generate sufficient quantities of these highly explosive chemicals to cause considerable collateral damage. Detection of TATP and HMTD by advanced sensing systems can provide the early warning necessary to prevent terror plots from coming to fruition. DMS is currently one of the foremost emerging technologies for the separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. DMS separates and identifies ions at ambient pressures by utilizing the non-linear dependence of an ion's mobility on the radio frequency (rf) electric field strength. GC is widely considered to be one of the leading analytical methods for the separation of chemical species in complex mixtures. Advances in the technique have led to the development of low-thermal-mass fast GC columns. These columns are capable of completing runs in less than 3 minutes. Fast GC columns are also more compact than their traditional counterparts. An earlier collaborative effort involving these authors optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for the detection of TATP (Figure 2). The unit combines the separation capabilities of GC with the selectivity of DMS. Analytes are identified both by their elution time from the column and by the characteristic response in the DMS spectrum. Analysis times required to obtain results for these analytes are approximately 80 seconds for TATP and 160 seconds for HMTD (Figure 3). The limit of detection for both TATP and HMTD is approximately 1 ng/{micro}L. Substances that could interfere with the detection of peroxide-based explosives have been studied. Both the GC elution time and the DMS spectral peak locations were unique and do not hinder the detection of either TATP or HMTD.« less
TRIEBENBACH, ALISON N.; VOGL, SIGRID J.; LOTSPEICH-COLE, LEDA; SIKES, DEREK S.; HAPP, GEORGE M.; HUEFFER, KARSTEN
2013-01-01
Tularemia is a zoonotic disease caused by the Category A bioterrorism agent Francisella tularensis. In Scandinavia, tularemia transmission by mosquitoes has been widely cited in the literature. We tested >2,500 mosquitoes captured in Alaska and found Francisella DNA in 30% of pooled samples. To examine the potential for transmission of Francisella by mosquitoes, we developed a mosquito model of Francisella infection. Larvae of Anopheles gambiae Giles and Aedes aegypti (L.) readily ingest F. tularensis but do not efficiently transfer infective doses of the bacterium to the pupal or adult stage. After a bloodmeal containing Francisella, adult female An. gambiae and Ae. aegypti retained detectable levels of Francisella DNA for 3 d, but when they took a second bloodmeal, the mammalian host was not infected. This study suggests that although Francisella DNA can be detected in a significant portion of wild-caught mosquitoes, transmission of Francisella is either very inefficient or is species dependent for the Francisella strain or the arthropod vector. PMID:20695280
NASA Technical Reports Server (NTRS)
Zeitlin, Nancy; Mullenix, Pamela; Wheeler, Raymond M.; Ruby, Anna Maria
2015-01-01
Previous research has shown that potential human pathogens have been detected on the International Space Station (ISS). New microorganisms are introduced with every exchange of crew and cargo. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e., ECLSS, environmental control and life support systems). Current microbial characterization methods require a culture-based enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of microorganisms. The culture-based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS samples requires that the microbes be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, inflight method of microbial detection, identification, and enumeration is needed. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.
Bioassays of quorum sensing compounds using Agrobacterium tumefaciens and Chromobacterium violaceum.
Chu, Weihua; Vattem, Dhiraj A; Maitin, Vatsala; Barnes, Mary B; McLean, Robert J C
2011-01-01
In most bacteria, a global level of regulation exists involving intercellular communication via the production and response to cell density-dependent signal molecules. This cell density-dependent regulation has been termed quorum sensing (QS). QS is a global regulator, which has been associated with a number of important features in bacteria including virulence regulation and biofilm formation. Consequently, there is considerable interest in understanding, detecting, and inhibiting QS. Acyl homoserine lactones (acyl HSLs) are used as extracellular QS signals by a variety of Gram-negative bacteria. Chromobacterium violaceum, a Gram-negative bacterium commonly found in soil and water, produces the characteristic purple pigment violacein, the production of which is regulated by acyl HSL-mediated QS. Based on this readily observed pigmentation phenotype, C. violaceum strains can be used to detect various aspects of acyl HSL-mediated QS activity. In another commonly used bioassay organism, Agrobacterium tumefaciens, QS can be detected by the use of a reporter gene such as lacZ. Here, we describe several commonly used approaches incorporating C. violaceum and A. tumefaciens that can be used to detect acyl HSLs and QS inhibition.
Detection of benzo[a]pyrene-guanine adducts in single-stranded DNA using the α-hemolysin nanopore
NASA Astrophysics Data System (ADS)
Perera, Rukshan T.; Fleming, Aaron M.; Johnson, Robert P.; Burrows, Cynthia J.; White, Henry S.
2015-02-01
The carcinogenic precursor benzo[a]pyrene (BP), a polycyclic aromatic hydrocarbon, is released into the environment through the incomplete combustion of hydrocarbons. Metabolism of BP in the human body yields a potent alkylating agent (benzo[a]pyrene diol epoxide, BPDE) that reacts with guanine (G) in DNA to form an adduct implicated in cancer initiation. We report that the α-hemolysin (αHL) nanopore platform can be used to detect a BPDE adduct to G in synthetic oligodeoxynucleotides. Translocation of a 41-mer poly-2‧-deoxycytidine strand with a centrally located BPDE adduct to G through αHL in 1 M KCl produces a unique multi-level current signature allowing the adduct to be detected. This readily distinguishable current modulation was observed when the BPDE-adducted DNA strand translocated from either the 5‧ or 3‧ directions. This study suggests that BPDE adducts and other large aromatic biomarkers can be detected with αHL, presenting opportunities for the monitoring, quantification, and sequencing of mutagenic compounds from cellular DNA samples.
Wang, Hong; Zhang, Peisheng; Tian, Yong; Zhang, Yuan; Yang, Heping; Chen, Shu; Zeng, Rongjin; Long, Yunfei; Chen, Jian
2018-04-30
A simple and readily available fluorescent probe is needed for the real-time monitoring of endogenous cysteine (Cys) levels in living cells, as such a probe could be used to study the role of Cys in related diseases. Herein, we report the first fluorescent probe based on carbon dots (CDs-FITA) for the selective and ratiometric imaging of endogenous Cys in live cells. In this ratiometric fluorescent probe, a fluorescein derivative (FITA) that recognizes Cys is covalently linked to the surfaces of carbon dots (CDs); employing CDs greatly improves the water solubility of the probe. Acrylate on FITA is selectively cleaved by Cys in aqueous solution under mild conditions, leading to a dramatic increase in the fluorescence from fluorescein. The probe therefore allows the highly selective ratiometric fluorescent detection of Cys even in the presence of various interferents. The as-prepared CDs-FITA showed excellent performance when applied to detect Cys in blood serum. In addition, due to its negligible cytotoxicity, the CDs-FITA can also be utilized for the real-time monitoring of endogenous cysteine (Cys) levels in living cells. Graphical abstract Illustration of the CD-based probe for Cys imaging in living cells.
Polydiacetylene-Based Liposomes: An "Optical Tongue" for Bacteria Detection and Identification
ERIC Educational Resources Information Center
West, Matthew R.; Hanks, Timothy W.; Watson, Rhett T.
2009-01-01
Food- and water-borne bacteria are a major health concern worldwide. Current detection methods are time-consuming and require sophisticated equipment that is not always readily available. However, new techniques based on nanotechnology are under development that will result in a new generation of sensors. In this experiment, liposomes are…
Phage-protease-peptide: a novel trifecta enabling multiplex detection of viable bacterial pathogens.
Alcaine, S D; Tilton, L; Serrano, M A C; Wang, M; Vachet, R W; Nugen, S R
2015-10-01
Bacteriophages represent rapid, readily targeted, and easily produced molecular probes for the detection of bacterial pathogens. Molecular biology techniques have allowed researchers to make significant advances in the bioengineering of bacteriophage to further improve speed and sensitivity of detection. Despite their host specificity, bacteriophages have not been meaningfully leveraged in multiplex detection of bacterial pathogens. We propose a proof-of-principal phage-based scheme to enable multiplex detection. Our scheme involves bioengineering bacteriophage to carry a gene for a specific protease, which is expressed during infection of the target cell. Upon lysis, the protease is released to cleave a reporter peptide, and the signal detected. Here we demonstrate the successful (i) modification of T7 bacteriophage to carry tobacco etch virus (TEV) protease; (ii) expression of TEV protease by Escherichia coli following infection by our modified T7, an average of 2000 units of protease per phage are produced during infection; and (iii) proof-of-principle detection of E. coli in 3 h after a primary enrichment via TEV protease activity using a fluorescent peptide and using a designed target peptide for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis (MALDI-TOF MS) analysis. This proof-of-principle can be translated to other phage-protease-peptide combinations to enable multiplex bacterial detection and readily adopted on multiple platforms, like MALDI-TOF MS or fluorescent readers, commonly found in labs.
Efficient search for a face by chimpanzees (Pan troglodytes).
Tomonaga, Masaki; Imura, Tomoko
2015-07-16
The face is quite an important stimulus category for human and nonhuman primates in their social lives. Recent advances in comparative-cognitive research clearly indicate that chimpanzees and humans process faces in a special manner; that is, using holistic or configural processing. Both species exhibit the face-inversion effect in which the inverted presentation of a face deteriorates their perception and recognition. Furthermore, recent studies have shown that humans detect human faces among non-facial objects rapidly. We report that chimpanzees detected chimpanzee faces among non-facial objects quite efficiently. This efficient search was not limited to own-species faces. They also found human adult and baby faces--but not monkey faces--efficiently. Additional testing showed that a front-view face was more readily detected than a profile, suggesting the important role of eye-to-eye contact. Chimpanzees also detected a photograph of a banana as efficiently as a face, but a further examination clearly indicated that the banana was detected mainly due to a low-level feature (i.e., color). Efficient face detection was hampered by an inverted presentation, suggesting that configural processing of faces is a critical element of efficient face detection in both species. This conclusion was supported by a simple simulation experiment using the saliency model.
Efficient search for a face by chimpanzees (Pan troglodytes)
Tomonaga, Masaki; Imura, Tomoko
2015-01-01
The face is quite an important stimulus category for human and nonhuman primates in their social lives. Recent advances in comparative-cognitive research clearly indicate that chimpanzees and humans process faces in a special manner; that is, using holistic or configural processing. Both species exhibit the face-inversion effect in which the inverted presentation of a face deteriorates their perception and recognition. Furthermore, recent studies have shown that humans detect human faces among non-facial objects rapidly. We report that chimpanzees detected chimpanzee faces among non-facial objects quite efficiently. This efficient search was not limited to own-species faces. They also found human adult and baby faces-but not monkey faces-efficiently. Additional testing showed that a front-view face was more readily detected than a profile, suggesting the important role of eye-to-eye contact. Chimpanzees also detected a photograph of a banana as efficiently as a face, but a further examination clearly indicated that the banana was detected mainly due to a low-level feature (i.e., color). Efficient face detection was hampered by an inverted presentation, suggesting that configural processing of faces is a critical element of efficient face detection in both species. This conclusion was supported by a simple simulation experiment using the saliency model. PMID:26180944
In vitro quantification of specific microRNA using molecular beacons
Baker, Meredith B.; Bao, Gang; Searles, Charles D.
2012-01-01
MicroRNAs (miRNAs), a class of non-coding RNAs, have become a major focus of molecular biology research because of their diverse genomic origin and ability to regulate an array of cellular processes. Although the biological functions of miRNA are yet to be fully understood, tissue levels of specific miRNAs have been shown to correlate with pathological development of disease. Here, we demonstrate that molecular beacons can readily distinguish mature- and pre-miRNAs, and reliably quantify miRNA expression. We found that molecular beacons with DNA, RNA and combined locked nucleic acid (LNA)–DNA backbones can all detect miRNAs of low (<1 nM) concentrations in vitro, with RNA beacons having the highest detection sensitivity. Furthermore, we found that molecular beacons have the potential to distinguish miRNAs that have slight variations in their nucleotide sequence. These results suggest that the molecular beacon-based approach to assess miRNA expression and distinguish mature and precursor miRNA species is quite robust, and has the promise for assessing miRNA levels in biological samples. PMID:22110035
Real-Time Series Resistance Monitoring in PV Systems Without the Need for I-V Curves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deceglie, Michael G.; Silverman, Timothy J.; Marion, Bill
We apply the physical principles of a familiar method, suns-V oc, to a new application: the real-time detection of series resistance changes in modules and systems operating outside. The real-time series resistance (RTSR) method that we describe avoids the need for collecting I-V curves or constructing full series resistance-free I-V curves. RTSR is most readily deployable at the module level on microinverters or module-integrated electronics, but it can also be extended to full strings. We found that automated detection of series resistance increases can provide early warnings of some of the most common reliability issues, which also pose fire risks,more » including broken ribbons, broken solder bonds, and contact problems in the junction or combiner box. We also describe the method in detail and describe a sample application to data collected from modules operating in the field.« less
Real-Time Series Resistance Monitoring in PV Systems Without the Need for IV Curves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deceglie, Michael G.; Silverman, Timothy J.; Marion, Bill
We apply the physical principles of a familiar method, suns-Voc, to a new application: the real-time detection of series resistance changes in modules and systems operating outside. The real-time series resistance (RTSR) method that we describe avoids the need for collecting IV curves or constructing full series-resistance-free IV curves. RTSR is most readily deployable at the module level on micro-inverters or module-integrated electronics, but it can also be extended to full strings. Automated detection of series resistance increases can provide early warnings of some of the most common reliability issues, which also pose fire risks, including broken ribbons, broken soldermore » bonds, and contact problems in the junction or combiner box. We describe the method in detail and describe a sample application to data collected from modules operating in the field.« less
Imaging Neural Activity Using Thy1-GCaMP Transgenic mice
Chen, Qian; Cichon, Joseph; Wang, Wenting; Qiu, Li; Lee, Seok-Jin R.; Campbell, Nolan R.; DeStefino, Nicholas; Goard, Michael J.; Fu, Zhanyan; Yasuda, Ryohei; Looger, Loren L.; Arenkiel, Benjamin R.; Gan, Wen-Biao; Feng, Guoping
2014-01-01
Summary The ability to chronically monitor neuronal activity in the living brain is essential for understanding the organization and function of the nervous system. The genetically encoded green fluorescent protein based calcium sensor GCaMP provides a powerful tool for detecting calcium transients in neuronal somata, processes, and synapses that are triggered by neuronal activities. Here we report the generation and characterization of transgenic mice that express improved GCaMPs in various neuronal subpopulations under the control of the Thy1 promoter. In vitro and in vivo studies show that calcium transients induced by spontaneous and stimulus-evoked neuronal activities can be readily detected at the level of individual cells and synapses in acute brain slices, as well as chronically in awake behaving animals. These GCaMP transgenic mice allow investigation of activity patterns in defined neuronal populations in the living brain, and will greatly facilitate dissecting complex structural and functional relationships of neural networks. PMID:23083733
Stanker, Larry H.; Scotcher, Miles C.; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert
2013-01-01
Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A – H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD’s) for individual antibodies ranging from 10 to 48 × 10−11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested. PMID:24253240
Stanker, Larry H; Scotcher, Miles C; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert
2013-11-18
Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A-H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD's) for individual antibodies ranging from 10 to 48 × 10-11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested.
NASA Technical Reports Server (NTRS)
Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.
2015-01-01
Previous research has shown that potentially destructive microorganisms and human pathogens have been detected on the International Space Station (ISS). The likelihood of introducing new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of the total microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS microbes requires that samples be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.
NASA Technical Reports Server (NTRS)
Khodadad, Christina L.; Birmele, Michele N.; Roman, Monsi; Hummerick, Mary E.; Smith, David J.; Wheeler, Raymond M.
2015-01-01
Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS). The potential to introduce new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Previous research has shown that microorganisms introduced to the ISS are readily transferred between crew and subsystems and back (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and a 48-hour incubation time. This increases the microbial load while detecting a limited number of microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification, To identify and enumerate ISS samples requires that samples to be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganism at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.
Brill, R L; Pawloski, J L; Helweg, D A; Au, W W; Moore, P W
1992-09-01
This study demonstrated the ability of a false killer whale (Pseudorca crassidens) to discriminate between two targets and investigated the parameters of the whale's emitted signals for changes related to test conditions. Target detection performance comparable to the bottlenose dolphin's (Tursiops truncatus) has previously been reported for echolocating false killer whales. No other echolocation capabilities have been reported. A false killer whale, naive to conditioned echolocation tasks, was initially trained to detect a cylinder in a "go/no-go" procedure over ranges of 3 to 8 m. The transition from a detection task to a discrimination task was readily achieved by introducing a spherical comparison target. Finally, the cylinder was successfully compared to spheres of two different sizes and target strengths. Multivariate analyses were used to evaluate the parameters of emitted signals. Duncan's multiple range tests showed significant decreases (df = 185, p less than 0.05) in both source level and bandwidth in the transition from detection to discrimination. Analysis of variance revealed a significant decrease in the number of clicks over test conditions [F(5.26) = 5.23, p less than 0.0001]. These data suggest that the whale relied on cues relevant to target shape as well as target strength, that changes in source level and bandwidth were task-related, that the decrease in clicks was associated with learning experience, and that Pseudorca's ability to discriminate shapes using echolocation may be comparable to that of Tursiops truncatus.
Depth of Lexical-Semantic Processing and Sentential Load
ERIC Educational Resources Information Center
Sanford, Alison J. S.; Sanford, Anthony J.; Filik, Ruth; Molle, Jo
2005-01-01
The text-change detection task has been used to show that changes are more readily detected for words that fall under narrow focus than broad focus (Sturt, Sanford, Stewart, & Dawydiak, 2004), and that narrow focus appears to lead to finer semantic distinctions being held in the representation of the word. The present experiments apply the same…
Yong, Hwanyul
2014-01-01
The reliability of a Korean black goat (Capra hircus coreanae) to detect estrus in Himalayan tahrs (Hemitragus jemlahicus) for an artificial breeding program was investigated. Estrus in six female Himalayan tahrs was synchronized using fluorogestone acetate (FGA) sponges. Thirteen days later, 200 IU of PMSG and 100 IU of hCG were injected before removing the sponges and simultaneously injecting 5 mg of PGF2α the next day. Penetration of the cervical canal and the thickness and location of red crayon marks were examined 40~43 h later. Two females treated with sponges containing 60 or 45 mg of FGA had estrogen levels of 8.7 and 11.1 pg/mL, respectively. No red marks were found on the backs of these two tahrs. The remaining females had higher levels of estradiol, and the red crayon marks were clearly shown. The cervical folds of these tahrs were readily penetrated and the insemination gun was smoothly inserted into the uterine body. In conclusion, a Korean domestic goat with its chest crayon-harnessed was successfully used to detect estrus of Himalayan tahrs. This technique might be utilized as a part of breeding programs for wild goats and avoid the need for a vasectomy of conspecific males. PMID:24690603
Lemieux, Sébastien
2006-08-25
The identification of differentially expressed genes (DEGs) from Affymetrix GeneChips arrays is currently done by first computing expression levels from the low-level probe intensities, then deriving significance by comparing these expression levels between conditions. The proposed PL-LM (Probe-Level Linear Model) method implements a linear model applied on the probe-level data to directly estimate the treatment effect. A finite mixture of Gaussian components is then used to identify DEGs using the coefficients estimated by the linear model. This approach can readily be applied to experimental design with or without replication. On a wholly defined dataset, the PL-LM method was able to identify 75% of the differentially expressed genes within 10% of false positives. This accuracy was achieved both using the three replicates per conditions available in the dataset and using only one replicate per condition. The method achieves, on this dataset, a higher accuracy than the best set of tools identified by the authors of the dataset, and does so using only one replicate per condition.
Comber, Joseph D.; Robinson, Tara M.; Siciliano, Nicholas A.; Snook, Adam E.; Eisenlohr, Laurence C.
2011-01-01
Major histocompatibility complex (MHC) class II-presented peptides can be derived from both exogenous (extracellular) and endogenous (biosynthesized) sources of antigen. Although several endogenous antigen-processing pathways have been reported, little is known about their relative contributions to global CD4+ T cell responses against complex antigens. Using influenza virus for this purpose, we assessed the role of macroautophagy, a process in which cytosolic proteins are delivered to the lysosome by de novo vesicle formation and membrane fusion. Influenza infection triggered productive macroautophagy, and autophagy-dependent presentation was readily observed with model antigens that naturally traffic to the autophagosome. Furthermore, treatments that enhance or inhibit macroautophagy modulated the level of presentation from these model antigens. However, validated enzyme-linked immunospot (ELISpot) assays of influenza-specific CD4+ T cells from infected mice using a variety of antigen-presenting cells, including primary dendritic cells, revealed no detectable macroautophagy-dependent component. In contrast, the contribution of proteasome-dependent endogenous antigen processing to the global influenza CD4+ response was readily appreciated. The contribution of macroautophagy to the MHC class II-restricted response may vary depending upon the pathogen. PMID:21525345
It's not black or white—on the range of vision and echolocation in echolocating bats
Boonman, Arjan; Bar-On, Yinon; Cvikel, Noam; Yovel, Yossi
2013-01-01
Around 1000 species of bats in the world use echolocation to navigate, orient, and detect insect prey. Many of these bats emerge from their roost at dusk and start foraging when there is still light available. It is however unclear in what way and to which extent navigation, or even prey detection in these bats is aided by vision. Here we compare the echolocation and visual detection ranges of two such species of bats which rely on different foraging strategies (Rhinopoma microphyllum and Pipistrellus kuhlii). We find that echolocation is better than vision for detecting small insects even in intermediate light levels (1–10 lux), while vision is advantageous for monitoring far-away landscape elements in both species. We thus hypothesize that, bats constantly integrate information acquired by the two sensory modalities. We suggest that during evolution, echolocation was refined to detect increasingly small targets in conjunction with using vision. To do so, the ability to hear ultrasonic sound is a prerequisite which was readily available in small mammals, but absent in many other animal groups. The ability to exploit ultrasound to detect very small targets, such as insects, has opened up a large nocturnal niche to bats and may have spurred diversification in both echolocation and foraging tactics. PMID:24065924
Quantitation of Protein Carbonylation by Dot Blot
Wehr, Nancy B.; Levine, Rodney L.
2012-01-01
Protein carbonylation is the most commonly used measure of oxidative modification of proteins. It is frequently measured spectrophotometrically or immunochemically by derivatizing proteins with the classical carbonyl reagent, 2,4-dinitrophenylhydrazine. We developed an immunochemical dot blot method for quantitation of protein carbonylation in homogenates or purified proteins. Dimethyl sulfoxide was employed as the solvent because it very efficiently extracts proteins from tissues and keeps them soluble. It also readily dissolves 2,4-dinitrophenylhydrazine and wets PVDF membranes. The detection limit is 0.19 ± 0.04 pmol carbonyl. Sixty ng protein is sufficient to measure protein carbonyl content. This level of sensitivity allowed measurement of protein carbonylation in individual Drosophila. PMID:22326366
Sampling guidelines for oral fluid-based surveys of group-housed animals.
Rotolo, Marisa L; Sun, Yaxuan; Wang, Chong; Giménez-Lirola, Luis; Baum, David H; Gauger, Phillip C; Harmon, Karen M; Hoogland, Marlin; Main, Rodger; Zimmerman, Jeffrey J
2017-09-01
Formulas and software for calculating sample size for surveys based on individual animal samples are readily available. However, sample size formulas are not available for oral fluids and other aggregate samples that are increasingly used in production settings. Therefore, the objective of this study was to develop sampling guidelines for oral fluid-based porcine reproductive and respiratory syndrome virus (PRRSV) surveys in commercial swine farms. Oral fluid samples were collected in 9 weekly samplings from all pens in 3 barns on one production site beginning shortly after placement of weaned pigs. Samples (n=972) were tested by real-time reverse-transcription PCR (RT-rtPCR) and the binary results analyzed using a piecewise exponential survival model for interval-censored, time-to-event data with misclassification. Thereafter, simulation studies were used to study the barn-level probability of PRRSV detection as a function of sample size, sample allocation (simple random sampling vs fixed spatial sampling), assay diagnostic sensitivity and specificity, and pen-level prevalence. These studies provided estimates of the probability of detection by sample size and within-barn prevalence. Detection using fixed spatial sampling was as good as, or better than, simple random sampling. Sampling multiple barns on a site increased the probability of detection with the number of barns sampled. These results are relevant to PRRSV control or elimination projects at the herd, regional, or national levels, but the results are also broadly applicable to contagious pathogens of swine for which oral fluid tests of equivalent performance are available. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
More Bits and Pieces: A Second Physics Miscellany
ERIC Educational Resources Information Center
Siddons, J. C.
1976-01-01
Described are five physics experiments utilizing inexpensive, readily available materials or materials normally found in a physics laboratory. Included are investigations of electrical charge, sound detection, thermal expansion, doppler effects, and the cycloid. (SL)
Schanke, J T; Conwell, C M; Durning, M; Fisher, J M; Golos, T G
1997-03-01
We have examined the expression of Pit-1 messenger RNA (mRNA) splice variants in the nonhuman primate pituitary and in rhesus and human placenta. Full-length complementary DNAs (cDNAs) representing Pit-1 and the Pit-1 beta splice variants were cloned from a rhesus monkey pituitary cDNA library and were readily detectable by RT-PCR with rhesus pituitary gland RNA. The Pit-1T variant previously reported in mouse pituitary tumor cell lines was not detectable in normal rhesus pituitary tissue, although two novel splice variants were detected. A cDNA approximating the rat Pit-1 delta 4 variant was cloned but coded for a truncated and presumably nonfunctional protein. Only by using a nested RT-PCR approach were Pit-1 and Pit-1 beta variants consistently detectable in both human and rhesus placental tissue. The Pit-1 beta variant mRNA was not detectable in JEG-3 choriocarcinoma cells unless the cells were stimulated with 8-Br-cAMP. Immunoblot studies with nuclear extracts from primary rhesus syncytiotrophoblast cultures or JEG-3 choriocarcinoma cells indicated that although mRNA levels were very low, Pit-1 protein was detectable in differentiated cytotrophoblasts, and levels increased after treatment with 8-Br-cAMP. Two major species of Pit-1 protein were detected that corresponded to the two major bands in rat pituitary GH3 cell nuclear extracts. Low levels of slightly larger bands also were seen, which may represent Pit-1 beta protein or phosphorylated species. We conclude that Pit-1 splice variants expressed in the primate pituitary gland differ from those in the rodent gland and that the Pit-1 and Pit-1 beta mRNAs expressed in the placenta give rise to a pattern of protein expression similar to that seen in pituitary cells, which is inducible by treatment with 8-Br-cAMP.
Molecular cloning and characterisation of banana fruit polyphenol oxidase.
Gooding, P S; Bird, C; Robinson, S P
2001-09-01
Polyphenol oxidase (PPO; EC 1.10.3.2) is the enzyme thought to be responsible for browning in banana [Musa cavendishii (AAA group, Cavendish subgroup) cv. Williams] fruit. Banana flesh was high in PPO activity throughout growth and ripening. Peel showed high levels of activity early in development but activity declined until ripening started and then remained constant. PPO activity in fruit was not substantially induced after wounding or treatment with 5-methyl jasmonate. Banana flowers and unexpanded leaf roll had high PPO activities with lower activities observed in mature leaves, roots and stem. Four different PPO cDNA clones were amplified from banana fruit (BPO1, BPO11, BPO34 and BPO35). Full-length cDNA and genomic clones were isolated for the most abundant sequence (BPO1) and the genomic clone was found to contain an 85-bp intron. Introns have not been previously found in PPO genes. Northern analysis revealed the presence of BPO1 mRNA in banana flesh early in development but little BPO1 mRNA was detected at the same stage in banana peel. BPO11 transcript was only detected in very young flesh and there was no detectable expression of BPO34 or BPO35 in developing fruit samples. PPO transcripts were also low throughout ripening in both flesh and peel. BPO1 transcripts were readily detected in flowers, stem, roots and leaf roll samples but were not detected in mature leaves. BPO11 showed a similar pattern of expression to BPO1 in these tissues but transcript levels were much lower. BPO34 and BPO35 mRNAs were only detected at a low level in flowers and roots and BPO34 transcript was detected in mature leaves, the only clone to do so. The results suggest that browning of banana fruit during ripening results from release of pre-existing PPO enzyme, which is synthesised very early in fruit development.
Measures of fish behavior as indicators of sublethal toxicosis during standard toxicity tests
Little, E.E.; DeLonay, A.J.
1996-01-01
Behavioral functions essential for growth and survival can be dramatically altered by sublethal exposure to toxicants. Measures of these behavioral responses are effective in detecting adverse effects of sublethal contaminant exposure. Behavioral responses of fishes can be qualitatively and quantitatively evaluated during routine toxicity tests. At selected intervals of exposure, qualitative evaluations are accomplished through direct observations, whereas video recordings are used for quantitative evaluations. Standardized procedures for behavioral evaluation are readily applicable to different fish species and provide rapid, sensitive, and ecologically relevant assessments of sublethal exposure. The methods are readily applied to standardized test protocols.
Seely, R J; Fahrney, D E
1984-01-01
Batch-grown Methanobacterium thermoautotrophicum cells grew nonexponentially in the absence of exogenous Pi until intracellular cyclic-2,3-diphosphoglycerate (cyclic DPG) had fallen below 2 mumol/g (dry weight), the limit of detection. Growth resumed immediately upon transfer to medium containing Pi Cyclic DPG levels were also below detection in Pi-limited chemostat cultures operating at a dilution rate of 0.173 h-1 (4-h doubling time), with reservoir Pi concentrations below 200 microM. At this dilution rate, the Pi concentration in the culture was 4 microM. An H2-limited steady state was achieved with 400 microM Pi in the inflowing medium (67 microM in the culture). The cyclic DPG content of these cells was 72 to 74 mumol/g, about one-third the amount in batch-grown cells. The specific growth rate accelerated immediately to 0.36 h-1 (1.9-h doubling time) under washout conditions at high dilution rate. The cellular content of cyclic DPG declined over a 2-h period, and then increased rapidly as the Pi level in the medium approached 200 microM. Expansion of the cyclic DPG pool coincided with a marked increase in Pi assimilation. These results indicated that M. thermoautotrophicum accumulated cyclic DPG only when Pi and H2 were readily available. PMID:6480564
Seely, R J; Fahrney, D E
1984-10-01
Batch-grown Methanobacterium thermoautotrophicum cells grew nonexponentially in the absence of exogenous Pi until intracellular cyclic-2,3-diphosphoglycerate (cyclic DPG) had fallen below 2 mumol/g (dry weight), the limit of detection. Growth resumed immediately upon transfer to medium containing Pi Cyclic DPG levels were also below detection in Pi-limited chemostat cultures operating at a dilution rate of 0.173 h-1 (4-h doubling time), with reservoir Pi concentrations below 200 microM. At this dilution rate, the Pi concentration in the culture was 4 microM. An H2-limited steady state was achieved with 400 microM Pi in the inflowing medium (67 microM in the culture). The cyclic DPG content of these cells was 72 to 74 mumol/g, about one-third the amount in batch-grown cells. The specific growth rate accelerated immediately to 0.36 h-1 (1.9-h doubling time) under washout conditions at high dilution rate. The cellular content of cyclic DPG declined over a 2-h period, and then increased rapidly as the Pi level in the medium approached 200 microM. Expansion of the cyclic DPG pool coincided with a marked increase in Pi assimilation. These results indicated that M. thermoautotrophicum accumulated cyclic DPG only when Pi and H2 were readily available.
Sewram, V; Nieuwoudt, T W; Marasas, W F; Shephard, G S; Ritieni, A
1999-10-15
A method is described using LC-MS for the detection of the mycotoxins fusaproliferin (FUS) and beauvericin (BEA) in cultures of Fusarium subglutinans and in naturally contaminated maize. Protonated molecular ion signals for FUS and BEA were observed at m/z 445 and m/z 784, respectively. Collision induced dissociation of the readily dehydrated protonated molecular ion of the sesterterpene FUS (m/z 427) led to the loss of another water molecule (m/z 409) and acetic acid (m/z 385), while the cyclic lactone trimer BEA fragmented to yield the protonated dimer (m/z 523) and monomer (m/z 262), respectively. Detection of FUS was best performed in the MS-MS mode while BEA displayed a stronger signal in the MS mode. The on-column instrumental detection limits for pure FUS and BEA were found to be 2 ng and 20 pg (S/N=2) while those in naturally contaminated maize were 1 microg/kg and 0.5 microg/kg, respectively. Five South African strains of F. subglutinans were analyzed following methanol extraction of which four produced FUS at levels between 330 mg/kg and 2630 mg/kg while only three produced BEA at levels between 140 mg/kg and 700 mg/kg. Application of this method to naturally contaminated maize samples from the Transkei region of South Africa showed FUS at levels of 8.8-39.6 microg/kg and BEA at 7.6-238.8 microg/kg.
Pancrazio, Joseph J; Gray, Samuel A; Shubin, Yura S; Kulagina, Nadezhda; Cuttino, David S; Shaffer, Kara M; Eisemann, Kevin; Curran, Anthony; Zim, Bret; Gross, Guenter W; O'Shaughnessy, Thomas J
2003-10-01
Cultured neuronal networks, which have the capacity to respond to a wide range of neuroactive compounds, have been suggested to be useful for both screening known analytes and unknown compounds for acute neuropharmacologic effects. Extracellular recording from cultured neuronal networks provides a means for extracting physiologically relevant activity, i.e. action potential firing, in a noninvasive manner conducive for long-term measurements. Previous work from our laboratory described prototype portable systems capable of high signal-to-noise extracellular recordings from cardiac myocytes. The present work describes a portable system tailored to monitoring neuronal extracellular potentials that readily incorporates standardized microelectrode arrays developed by and in use at the University of North Texas. This system utilizes low noise amplifier and filter boards, a two-stage thermal control system with integrated fluidics and a graphical user interface for data acquisition and control implemented on a personal computer. Wherever possible, off-the-shelf components have been utilized for system design and fabrication. During use with cultured neuronal networks, the system typically exhibits input referred noise levels of only 4-6 microVRMS, such that extracellular potentials exceeding 40 microV can be readily resolved. A flow rate of up to 1 ml/min was achieved while the cell recording chamber temperature was maintained within a range of 36-37 degrees C. To demonstrate the capability of this system to resolve small extracellular potentials, pharmacological experiments with cultured neuronal networks have been performed using ion channel blockers, tetrodotoxin and tityustoxin. The implications of the experiments for neurotoxin detection are discussed.
A Molecular Fluorescent Probe for Targeted Visualization of Temperature at the Endoplasmic Reticulum
Arai, Satoshi; Lee, Sung-Chan; Zhai, Duanting; Suzuki, Madoka; Chang, Young Tae
2014-01-01
The dynamics of cellular heat production and propagation remains elusive at a subcellular level. Here we report the first small molecule fluorescent thermometer selectively targeting the endoplasmic reticulum (ER thermo yellow), with the highest sensitivity reported so far (3.9%/°C). Unlike nanoparticle thermometers, ER thermo yellow stains the target organelle evenly without the commonly encountered problem of aggregation, and successfully demonstrates the ability to monitor intracellular temperature gradients generated by external heat sources in various cell types. We further confirm the ability of ER thermo yellow to monitor heat production by intracellular Ca2+ changes in HeLa cells. Our thermometer anchored at nearly-zero distance from the ER, i.e. the heat source, allowed the detection of the heat as it readily dissipated, and revealed the dynamics of heat production in real time at a subcellular level. PMID:25330751
Interpreting Black-Box Classifiers Using Instance-Level Visual Explanations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamagnini, Paolo; Krause, Josua W.; Dasgupta, Aritra
2017-05-14
To realize the full potential of machine learning in diverse real- world domains, it is necessary for model predictions to be readily interpretable and actionable for the human in the loop. Analysts, who are the users but not the developers of machine learning models, often do not trust a model because of the lack of transparency in associating predictions with the underlying data space. To address this problem, we propose Rivelo, a visual analytic interface that enables analysts to understand the causes behind predictions of binary classifiers by interactively exploring a set of instance-level explanations. These explanations are model-agnostic, treatingmore » a model as a black box, and they help analysts in interactively probing the high-dimensional binary data space for detecting features relevant to predictions. We demonstrate the utility of the interface with a case study analyzing a random forest model on the sentiment of Yelp reviews about doctors.« less
MacAlpine, D M; Perlman, P S; Butow, R A
1998-06-09
Abf2p is a high mobility group (HMG) protein found in yeast mitochondria that is required for the maintenance of wild-type (rho+) mtDNA in cells grown on fermentable carbon sources, and for efficient recombination of mtDNA markers in crosses. Here, we show by two-dimensional gel electrophoresis that Abf2p promotes or stabilizes Holliday recombination junction intermediates in rho+ mtDNA in vivo but does not influence the high levels of recombination intermediates readily detected in the mtDNA of petite mutants (rho-). mtDNA recombination junctions are not observed in rho+ mtDNA of wild-type cells but are elevated to detectable levels in cells with a null allele of the MGT1 gene (Deltamgt1), which codes for a mitochondrial cruciform-cutting endonuclease. The level of recombination intermediates in rho+ mtDNA of Deltamgt1 cells is decreased about 10-fold if those cells contain a null allele of the ABF2 gene. Overproduction of Abf2p by >/= 10-fold in wild-type rho+ cells, which leads to mtDNA instability, results in a dramatic increase in mtDNA recombination intermediates. Specific mutations in the two Abf2p HMG boxes required for DNA binding diminishes these responses. We conclude that Abf2p functions in the recombination of rho+ mtDNA.
Power analysis of QTL detection in half-sib families using selective DNA pooling
Baro, Jesús Á; Carleos, Carlos; Corral, Norberto; López, Teresa; Cañón, Javier
2001-01-01
Individual loci of economic importance (QTL) can be detected by comparing the inheritance of a trait and the inheritance of loci with alleles readily identifiable by laboratory methods (genetic markers). Data on allele segregation at the individual level are costly and alternatives have been proposed that make use of allele frequencies among progeny, rather than individual genotypes. Among the factors that may affect the power of the set up, the most important are those intrinsic to the QTL: the additive effect of the QTL, and its dominance, and distance between markers and QTL. Other factors are relative to the choice of animals and markers, such as the frequency of the QTL and marker alleles among dams and sires. Data collection may affect the detection power through the size of half-sib families, selection rate within families, and the technical error incurred when estimating genetic frequencies. We present results for a sensitivity analysis for QTL detection using pools of DNA from selected half-sibs. Simulations showed that conclusive detection may be achieved with families of at least 500 half-sibs if sires are chosen on the criteria that most of their marker alleles are either both missing, or one is fixed, among dams. PMID:11403746
Measuring and Validating the Levels of Brain-Derived Neurotrophic Factor in Human Serum
Naegelin, Yvonne; Dingsdale, Hayley; Säuberli, Katharina; Schädelin, Sabine; Kappos, Ludwig
2018-01-01
Brain-derived neurotrophic factor (BDNF) secreted by neurons is a significant component of synaptic plasticity. In humans, it is also present in blood platelets where it accumulates following its biosynthesis in megakaryocytes. BDNF levels are thus readily detectable in human serum and it has been abundantly speculated that they may somehow serve as an indicator of brain function. However, there is a great deal of uncertainty with regard to the range of BDNF levels that can be considered normal, how stable these values are over time and even whether BDNF levels can be reliably measured in serum. Using monoclonal antibodies and a sandwich ELISA, this study reports on BDNF levels in the serum of 259 volunteers with a mean value of 32.69 ± 8.33 ng/ml (SD). The mean value for the same cohort after 12 months was not significantly different (N = 226, 32.97 ± 8.36 ng/ml SD, p = 0.19). Power analysis of these values indicates that relatively large cohorts are necessary to identify significant differences, requiring a group size of 60 to detect a 20% change. The levels determined by ELISA could be validated by Western blot analyses using a BDNF monoclonal antibody. While no association was observed with gender, a weak, positive correlation was found with age. The overall conclusions are that BDNF levels can be reliably measured in human serum, that these levels are quite stable over one year, and that comparisons between two populations may only be meaningful if cohorts of sufficient sizes are assembled. PMID:29662942
Kim, Kyeong Seok; Yang, Hun Yong; Song, Hosup; Kang, Ye Rim; Kwon, JiHoon; An, JiHye; Son, Ji Yeon; Kwack, Seung Jun; Kim, Young-Mi; Bae, Ok-Nam; Ahn, Mee-Young; Lee, Jaewon; Yoon, Sungpil; Lee, Byung Mu; Kim, Hyung Sik
2017-01-01
Acute kidney injury (AKI) is associated with increased mortality rate in patients but clinically available biomarkers for disease detection are currently not available. Recently, a new biomarker, selenium-binding protein 1 (SBP1), was identified for detection of nephrotoxicity using proteomic analysis. The aim of this study was to assess the sensitivity of urinary SBP1 levels as an early detection of AKI using animal models such as cisplatin or ischemia/reperfusion (I/R). Sprague-Dawley rats were injected with cisplatin (6 mg/kg, once i.p.) and sacrificed at 1, 3, or 5 days after treatment. Ischemia was achieved by bilaterally occluding both kidneys with a microvascular clamp for 45 min and verified visually by a change in tissue color. After post-reperfusion, urine samples were collected at 9, 24, and 48 hr intervals. Urinary excretion of protein-based biomarkers was measured by Western blot analysis. In cisplatin-treated rats, mild histopathologic alterations were noted at day 1 which became severe at day 3. Blood urea nitrogen (BUN) and serum creatinine (SCr) levels were significantly increased at day 3. Levels of urinary excretion of SBP1, neutrophil gelatinase-associated lipocalin (NGAL), and a tissue inhibitor of metalloproteinase-1 (TIMP-1) were markedly elevated at day 3 and 5 following drug treatment. In the vehicle-treated I/R group, serum levels of BUN and SCr and AST activity were significantly increased compared to sham. Urinary excretion of SBP1 and NGAL rose markedly following I/R. The urinary levels of SBP1, NGAL, TIMP-1, and KIM-1 proteins excreted by AKI patients and normal subjects were compared. Among these proteins, a marked rise in SBP1 was observed in urine of patients with AKI compared to normal subjects. Based upon receiver-operator curves (ROC), SBP1 displayed a higher area under the curve (AUC) scores than levels of SCr, BUN, total protein, and glucose. In particular, SBP1 protein was readily detected in small amounts of urine without purification. Data thus indicate that urinary excretion of SBP1 may be useful as a reliable biomarker for early diagnosis of AKI in patients.
VRPI Temporal Progression of Closed Globe Injury from Blast Exposure
2015-09-01
significant increases in VEGF have been reported in many ocular disorders including diabetic retinopathy , diffuse macular edema, retinal vein...Open globe injury is often readily identifiable and typically undergoes urgent surgical repair. However, closed globe injury may not be detected ...including shrapnel or debris to the eye, is easily identified and rapidly treated. Closed globe trauma may not be detected right away, and little is
Evaluation of landsat imagery for detecting ice storm damage in upland forests of Eastern Kentucky
Henry W. McNab; Tracy Roof; Jeffrey F. Lewis; David L. Loftis
2007-01-01
Two categories of forest canopy damage (none to light vs. moderate to heavy) resulting from a 2003 ice storm in eastern Kentucky could be identified on readily available Landsat Thematic Mapper imagery using change detection techniques to evaluate the ratio of spectral bands 4 and 5. Regression analysis was used to evaluate several model formulations based on the...
Utility of Pulse Oximetry to Detect Aspiration: An Evidence-Based Systematic Review.
Britton, Deanna; Roeske, Amy; Ennis, Stephanie K; Benditt, Joshua O; Quinn, Cassie; Graville, Donna
2018-06-01
Pulse oximetry is a commonly used means to measure peripheral capillary oxyhemoglobin saturation (SpO 2 ). Potential use of pulse oximetry to detect aspiration is attractive to clinicians, as it is readily available, quick, and noninvasive. However, research regarding validity has been mixed. This systematic review examining evidence on the use of pulse oximetry to detect a decrease in SpO 2 indicating aspiration during swallowing is undertaken to further inform clinical practice in dysphagia assessment. A multi-engine electronic search was conducted on 8/25/16 and updated on 4/8/17 in accordance with standards published by the Preferred Reporting for Items for Systematic Reviews and Meta-Analysis Protocols (PRISMA). Inclusion criteria included use of pulse oximetry to detect aspiration with simultaneous confirmation of aspiration via a gold standard instrumental study. Keywords included dysphagia or aspiration AND pulse oximetry. Articles meeting criteria were reviewed by two blinded co-investigators. The search yielded 294 articles, from which 19 were judged pertinent and reviewed in full. Ten met the inclusion criteria and all were rated at Level III-2 on the Australian Diagnostic Levels of Evidence. Study findings were mixed with sensitivity ranging from 10 to 87%. Potentially confounding variables were observed in all studies reviewed, and commonly involved defining "desaturation" within a standard measurement error range (~ 2%), mixed populations, mixed viscosities/textures observed during swallowing, and lack of comparison group. The majority of studies failed to demonstrate an association between observed aspiration and oxygen desaturation. Current evidence does not support the use of pulse oximetry to detect aspiration.
USDA-ARS?s Scientific Manuscript database
Bovine tuberculosis (TB) is generally considered a slowly progressive disease of extended duration (lasting years) and most cattle do not exhibit readily apparent clinical signs of infection until late in the course of disease. Currently, agent-based strategies for the detection of tuberculous cattl...
Fission Signatures for Nuclear Material Detection
NASA Astrophysics Data System (ADS)
Gozani, Tsahi
2009-06-01
Detection and interdiction of nuclear materials in all forms of transport is one of the most critical security issues facing the United States and the rest of the civilized world. Naturally emitted gamma rays by these materials, while abundant and detectable when unshielded, are low in energy and readily shielded. X-ray radiography is useful in detecting the possible presence of shielding material. Positive detection of concealed nuclear materials requires methods which unequivocally detect specific attributes of the materials. These methods typically involve active interrogation by penetrating radiation of neutrons, photons or other particles. Fortunately, nuclear materials, probed by various types of radiation, yield very unique and often strong signatures. Paramount among them are the detectable fission signatures, namely prompt neutrons and gamma rays, and delayed neutrons gamma rays. Other useful signatures are the nuclear states excited by neutrons, via inelastic scattering, or photons, via nuclear resonance fluorescence and absorption. The signatures are very different in magnitude, level of specificity, ease of excitation and detection, signal to background ratios, etc. For example, delayed neutrons are very unique to the fission process, but are scarce, have low energy, and hence are easily absorbed. Delayed gamma rays are more abundant but "featureless", and have a higher background from natural sources and more importantly, from activation due to the interrogation sources. The prompt fission signatures need to be measured in the presence of the much higher levels of probing radiation. This requires taking special measures to look for the signatures, sometimes leading to a significant sensitivity loss or a complete inability to detect them. Characteristic gamma rays induced in nuclear materials reflecting their nuclear structure, while rather unique, require very high intensity of interrogation radiation and very high resolution in energy and/or time. The trade off of signatures, their means of stimulation, and methods of detection, will be reviewed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kulka, Michael, E-mail: michael.kulka@fda.hhs.go; Calvo, Mona S., E-mail: mona.calvo@fda.hhs.go; Ngo, Diana T., E-mail: diana.ngo@fda.hhs.go
2009-05-25
The latent, constitutively expressed protein RNase L is activated in coxsackievirus and HAV strain 18f infected FRhK-4 cells. Endogenous oligoadenylate synthetase (OAS) from uninfected and virus infected cell extracts synthesizes active forms of the triphosphorylated 2-5A oligomer (the only known activator of RNase L) in vitro and endogenous 2-5A is detected in infected cell extracts. However, only the largest OAS isoform, OAS3, is readily detected throughout the time course of infection. While IFNbeta treatment results in an increase in the level of all three OAS isoforms in FRhK-4 cells, IFNbeta pretreatment does not affect the temporal onset or enhancement ofmore » RNase L activity nor inhibit virus replication. Our results indicate that CVB1 and HAV/18f activate the 2-5OAS/RNase L pathway in FRhK-4 cells during permissive infection through endogenous levels of OAS, but contrary to that reported for some picornaviruses, CVB1 and HAV/18f replication is insensitive to this activated antiviral pathway.« less
Whyatt, Robin M; Barr, Dana B; Camann, David E; Kinney, Patrick L; Barr, John R; Andrews, Howard F; Hoepner, Lori A; Garfinkel, Robin; Hazi, Yair; Reyes, Andria; Ramirez, Judyth; Cosme, Yesenia; Perera, Frederica P
2003-01-01
We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy. PMID:12727605
Selective solvent-free chromium detection using cadmium-free quantum dots
NASA Astrophysics Data System (ADS)
Meylemans, Heather A.; Baca, Alfred J.; Cambrea, Lee R.; Ostrom, Gregory S.
2017-07-01
Currently, the method of choice to test for the presence of chromium in water is to submit samples to a lab for testing. We present a simple field-ready test that is selective for the presence of chromium at concentrations of 100 ppb or greater. The Environmental Protection Agency maximum contaminant level (MCL) for total chromium is 100 ppb. This test uses a simple on/off fluorescent screening employing the use of silver indium sulfide (AgInS2) quantum dots (QDs). These QDs were impregnated into cotton pads to simplify field testing without the need for solvents or other liquid chemicals to be present. The change in fluorescence is instant and can be readily observed by eye with the use of a UV flashlight.
Batteryless magneto-driven portable radiac
Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Wolf, M.A.; Umbarger, C.J.
1984-10-19
A hand-powerd alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Mueller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.
Quantitation of protein carbonylation by dot blot.
Wehr, Nancy B; Levine, Rodney L
2012-04-15
Protein carbonylation is the most commonly used measure of oxidative modification of proteins. It is frequently measured spectrophotometrically or immunochemically by derivatizing proteins with the classical carbonyl reagent, 2,4-dinitrophenylhydrazine. We developed an immunochemical dot blot method for quantitation of protein carbonylation in homogenates or purified proteins. Dimethyl sulfoxide was employed as the solvent because it very efficiently extracts proteins from tissues and keeps them soluble. It also readily dissolves 2,4-dinitrophenylhydrazine and wets polyvinylidene difluoride (PVDF) membranes. The detection limit is 0.19 ± 0.04 pmol of carbonyl, and 60 ng of protein is sufficient to measure protein carbonyl content. This level of sensitivity allowed measurement of protein carbonylation in individual Drosophila. Copyright © 2012 Elsevier Inc. All rights reserved.
Henderson, Gail; Jaber, Tareq; Carpenter, Dale; Wechsler, Steven L; Jones, Clinton
2009-09-01
Expression of the first 1.5 kb of the latency-associated transcript (LAT) that is encoded by herpes simplex virus type 1 (HSV-1) is sufficient for wild-type (wt) levels of reactivation from latency in small animal models. Peptide-specific immunoglobulin G (IgG) was generated against open reading frames (ORFs) that are located within the first 1.5 kb of LAT coding sequences. Cells stably transfected with LAT or trigeminal ganglionic neurons of mice infected with a LAT expressing virus appeared to express the L2 or L8 ORF. Only L2 ORF expression was readily detected in trigeminal ganglionic neurons of latently infected mice.
Batteryless magneto-driven portable radiac
Waechter, David A.; Bjarke, George O.; Trujillo, Faustin; Wolf, Michael A.; Umbarger, C. John
1986-01-01
A hand-powered alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Muller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.
Duthie, Malcolm S; Guderian, Jeffery A; Vallur, Aarthy C; Misquith, Ayesha; Liang, Hong; Mohamath, Raodoh; Luquetti, Alejandro O; Carter, Darrick; Tavares, Suelene N B; Reed, Steven G
2016-03-01
We previously reported that tandem repeat (TR) proteins from Trypanosoma cruzi could serve as targets of the antibody response and be useful as diagnostic indicators. To optimize reagents for detecting T. cruzi infection we evaluated individual TR proteins and identified several that were recognized by the majority of Chagas patient's sera collected from individuals form Brazil. We then produced novel, recombinant fusion proteins to combine the reactive TR proteins into a single diagnostic product. Direct comparison of the antibody response of serum samples that were readily detected by the established fusion antigen used in commercial detection of Chagas disease, TcF, revealed strong responses to TcF43 and TcF26 proteins. While the TcF43 and TcF26 antigens enhanced detection and strength of signal, they did not compromise the specificity of detection compared to that obtained with TcF. Finally, it was apparent by testing against a panel of 84 serum samples assembled on the basis of moderate or weak reactivity against TcF (mostly signal:noise <5) that TcF43 and TcF26 could more strongly detected by many of the sera that had low TcF antibody levels. Taken together, these data indicate that TcF43 and TcF26 could be used to enhance the detection of T. cruzi infection as well as supporting a diagnosis of Chagas disease. Copyright © 2016 Elsevier Inc. All rights reserved.
Wijaya, I Putu Mahendra; Nie, Tey Ju; Rodriguez, Isabel; Mhaisalkar, Subodh G
2010-06-07
The advent of a carbon nanotube liquid-gated transistor (LGFET) for biosensing applications allows the possibility of real-time and label-free detection of biomolecular interactions. The use of an aqueous solution as dielectric, however, has traditionally restricted the operating gate bias (VG) within |VG| < 1 V, due to the electrolysis of water. Here, we propose pulsed-gating as a facile method to extend the operation window of LGFETs to |VG| > 1 V. A comparison between simulation and experimental results reveals that at voltages in excess of 1 V, the LGFET sensing mechanism has a contribution from two factors: electrostatic gating as well as capacitance modulation. Furthermore, the large IDS drop observed in the |VG| > 1 V region indicates that pulsed-gating may be readily employed as a simple method to amplify the signal in the LGFET and pushes the detection limit down to attomolar concentration levels, an order of magnitude improvement over conventionally employed DC VG biasing.
Simon, Julianna C.; Wang, Yak-Nam; Cunitz, Bryan W.; Thiel, Jeffrey; Starr, Frank; Liu, Ziyue; Bailey, Michael R.
2016-01-01
Bone demineralization, dehydration, and stasis put astronauts at an increased risk of forming kidney stones in space. The color-Doppler ultrasound “twinkling artifact”, which highlights kidney stones with color, can make stones readily detectable with ultrasound; however our previous results suggest twinkling is caused by microbubbles on the stone surface which could be affected by the elevated levels of carbon dioxide found on space vehicles. Four pigs were implanted with kidney stones and imaged with ultrasound while the anesthetic carrier gas oscillated between oxygen and air containing 0.8% carbon dioxide. Upon exposing pigs to 0.8% carbon dioxide, twinkling was significantly reduced after 9–25 minutes and recovered when the carrier gas returned to oxygen. These trends repeated when pigs were again exposed to 0.8% carbon dioxide followed by oxygen. The reduction of twinkling from exposure to elevated carbon dioxide may make kidney stone detection with twinkling difficult in current space vehicles. PMID:28190622
Use of satellite imagery for wildland resource evaluation
NASA Technical Reports Server (NTRS)
Tueller, P. T. (Principal Investigator)
1972-01-01
The author has identified the following significant results. Accurate identification and delineation of crested wheatgrass seedlings has enabled a broad inventory of this resource. The entire state of Nevada is being inventoried for crested wheatgrass seedlings. Irrigated fields and pastures are easily visible from ERTS-1 imagery and were quantified in total acres on 12,500 square miles of the state. Recent fire scars may be monitored and inventoried from satellite-borne imagery. Inventory and quantification of large native meadows of Nevada have been accomplished on one frame of ERTS-1 data. This inventory would not have been economically feasible with any known ground inventory method. The U-2 sequential data taken in the spring revealed several resource management oriented phenological changes in the vegetation. The green-up of grasses and shrubs was detected on the imagery and supplied a good indicator for livestock turn-out dates. Water level manipulations in the Ruby Marsh were readily detected by noting changes in vegetation growth and reflectance.
Postage stamp-sized array sensor for the sensitive screening test of heavy-metal ions.
Zhang, Yu; Li, Xiao; Li, Hui; Song, Ming; Feng, Liang; Guan, Yafeng
2014-10-07
The sensitive determination of heavy-metal ions has been widely investigated in recent years due to their threat to the environment and to human health. Among various analytical detection techniques, inexpensive colorimetric testing papers/strips play a very important role. The limitation, however, is also clear: the sensitivity is usually low and the selectivity is poor. In this work, we have developed a postage stamp-sized array sensor composed of nine commercially available heterocyclic azo indicators. Combining filtration-based enrichment with an array of technologies-based pattern-recognition, we have obtained the discrimination capability for seven heavy-metal ions (Hg(2+), Pb(2+), Ag(+), Ni(2+), Cu(2+), Zn(2+), and Co(2+)) at their Chinese wastewater discharge standard concentrations. The allowable detection level of Hg(2+) was down to 0.05 mg L(-1). The heavy-metal ions screening test was readily achieved using a standard chemometric approach. And the array sensor applied well in real water samples.
Color changing photonic crystals detect blast exposure
Cullen, D. Kacy; Xu, Yongan; Reneer, Dexter V.; Browne, Kevin D.; Geddes, James W.; Yang, Shu; Smith, Douglas H.
2010-01-01
Blast-induced traumatic brain injury (bTBI) is the “signature wound” of the current wars in Iraq and Afghanistan. However, with no objective information of relative blast exposure, warfighters with bTBI may not receive appropriate medical care and are at risk of being returned to the battlefield. Accordingly, we have created a colorimetric blast injury dosimeter (BID) that exploits material failure of photonic crystals to detect blast exposure. Appearing like a colored sticker, the BID is fabricated in photosensitive polymers via multi-beam interference lithography. Although very stable in the presence of heat, cold or physical impact, sculpted micro- and nano-structures of the BID are physically altered in a precise manner by blast exposure, resulting in color changes that correspond with blast intensity. This approach offers a lightweight, power-free sensor that can be readily interpreted by the naked eye. Importantly, with future refinement this technology may be deployed to identify soldiers exposed to blast at levels suggested to be supra-threshold for non-impact blast-induced mild TBI. PMID:21040795
Near-infrared diode laser hydrogen fluoride monitor for dielectric etch
NASA Astrophysics Data System (ADS)
Xu, Ning; Pirkle, David R.; Jeffries, Jay B.; McMillin, Brian; Hanson, Ronald K.
2004-11-01
A hydrogen fluoride (HF) monitor, using a tunable diode laser, is designed and used to detect the etch endpoints for dielectric film etching in a commercial plasma reactor. The reactor plasma contains HF, a reaction product of feedstock gas CF4 and the hydrogen-containing films (photoresist, SiOCH) on the substrate. A near-infrared diode laser is used to scan the P(3) transition in the first overtone of HF near 1.31 μm to monitor changes in the level of HF concentration in the plasma. Using 200 ms averaging and a signal modulation technique, we estimate a minimum detectable HF absorbance of 6×10-5 in the etch plasma, corresponding to an HF partial pressure of 0.03 mTorr. The sensor could indicate, in situ, the SiOCH over tetraethoxysilane oxide (TEOS) trench endpoint, which was not readily discerned by optical emission. These measurements demonstrate the feasibility of a real-time diode laser-based sensor for etch endpoint monitoring and a potential for process control.
Choi, Jane Ru; Yong, Kar Wey; Tang, Ruihua; Gong, Yan; Wen, Ting; Yang, Hui; Li, Ang; Chia, Yook Chin; Pingguan-Murphy, Belinda; Xu, Feng
2017-01-01
Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Nikolaou, Anastasios; Saxami, Georgia; Kourkoutas, Yiannis; Galanis, Alex
2011-02-01
In this study we present a novel multiplex PCR assay for rapid and efficient detection of Lactobacillus delbrueckii subsp. bulgaricus. The accuracy of our method was confirmed by the successful identification of L. delbrueckii subsp. bulgaricus in commercial yoghurts and food supplements and it may be readily applied to the food industry. Copyright © 2010 Elsevier B.V. All rights reserved.
Liver Rapid Reference Set Application: Hiro Yamada - Wako (2011) — EDRN Public Portal
Measure clinical effectiveness of AFP-L3 and DCP for early detection of HCC in patient samples collected prospectively during surveillance. However since such samples are not readily available in the USA the reference set samples are well characterized and studied, gaining access to these samples will allow Wako to quickly measure clinical effectiveness of AFP-L3 and DCP in detecting early HCC.
Frequency modulation detection atomic force microscopy in the liquid environment
NASA Astrophysics Data System (ADS)
Jarvis, S. P.; Ishida, T.; Uchihashi, T.; Nakayama, Y.; Tokumoto, H.
True atomic resolution imaging using frequency modulation detection is already well established in ultra-high vacuum. In this paper we demonstrate that it also has great potential in the liquid environment. Using a combination of magnetic activation and high-aspect-ratio carbon nanotube probes, we show that imaging can be readily combined with point spectroscopy, revealing both the tip-sample interaction and the structure of the intermediate liquid.
Surface-based GPR underestimates below-stump root biomass
John R. Butnor; Lisa J. Samuelson; Thomas A. Stokes; Kurt H. Johnsen; Peter H. Anderson; Carlos A. Gonzalez-Benecke
2016-01-01
Aims While lateral root mass is readily detectable with ground penetrating radar (GPR), the roots beneath a tree (below-stump) and overlapping lateral roots near large trees are problematic for surface-based antennas operated in reflection mode. We sought to determine if tree size (DBH) effects GPR root detection proximal to longleaf pine (Pinus palustris Mill) and if...
Long-range surface plasmon polariton detection with a graphene photodetector.
Ee, Ho-Seok; No, You-Shin; Kim, Jinhyung; Park, Hong-Gyu; Seo, Min-Kyo
2018-06-15
We present an integration of a single Ag nanowire (NW) with a graphene photodetector and demonstrate an efficient and compact detection of long-range surface plasmon polaritons (SPPs). Atomically thin graphene provides an ideal platform to detect the evanescent electric field of SPPs extremely bound at the interface of the Ag NW and glass substrate. Scanning photocurrent microscopy directly visualizes a polarization-dependent excitation and detects the SPPs. The SPP detection responsivity is readily controlled up to ∼17 mA/W by the drain-source voltage. We believe that the graphene SPP detector will be a promising building block for highly integrated photonic and optoelectronic circuits.
Xia, Jingya; Veselenak, Ronald L.; Gorder, Summer R.; Bourne, Nigel; Milligan, Gregg N.
2014-01-01
Despite its importance in modulating HSV-2 pathogenesis, the nature of tissue-resident immune memory to HSV-2 is not completely understood. We used genital HSV-2 infection of guinea pigs to assess the type and location of HSV-specific memory cells at peripheral sites of HSV-2 infection. HSV-specific antibody-secreting cells were readily detected in the spleen, bone marrow, vagina/cervix, lumbosacral sensory ganglia, and spinal cord of previously-infected animals. Memory B cells were detected primarily in the spleen and to a lesser extent in bone marrow but not in the genital tract or neural tissues suggesting that the HSV-specific antibody-secreting cells present at peripheral sites of HSV-2 infection represented persisting populations of plasma cells. The antibody produced by these cells isolated from neural tissues of infected animals was functionally relevant and included antibodies specific for HSV-2 glycoproteins and HSV-2 neutralizing antibodies. A vigorous IFN-γ-secreting T cell response developed in the spleen as well as the sites of HSV-2 infection in the genital tract, lumbosacral ganglia and spinal cord following acute HSV-2 infection. Additionally, populations of HSV-specific tissue-resident memory T cells were maintained at these sites and were readily detected up to 150 days post HSV-2 infection. Unlike the persisting plasma cells, HSV-specific memory T cells were also detected in uterine tissue and cervicothoracic region of the spinal cord and at low levels in the cervicothoracic ganglia. Both HSV-specific CD4+ and CD8+ resident memory cell subsets were maintained long-term in the genital tract and sensory ganglia/spinal cord following HSV-2 infection. Together these data demonstrate the long-term maintenance of both humoral and cellular arms of the adaptive immune response at the sites of HSV-2 latency and virus shedding and highlight the utility of the guinea pig infection model to investigate tissue-resident memory in the setting of HSV-2 latency and spontaneous reactivation. PMID:25485971
The Lung Surfactant System in Adult Respiratory Distress Syndrome.
1979-12-01
jfugation. No significant differences in phospholipid distribution or phosphatidyl- choline (PC) fatty acid composition can be detected in...the fact that amniotic fluid from uncomplicated term pregnancies could be readily used as the source for normal surfactant. During the course of our
Janky, Rekin's; van Helden, Jacques
2008-01-23
The detection of conserved motifs in promoters of orthologous genes (phylogenetic footprints) has become a common strategy to predict cis-acting regulatory elements. Several software tools are routinely used to raise hypotheses about regulation. However, these tools are generally used as black boxes, with default parameters. A systematic evaluation of optimal parameters for a footprint discovery strategy can bring a sizeable improvement to the predictions. We evaluate the performances of a footprint discovery approach based on the detection of over-represented spaced motifs. This method is particularly suitable for (but not restricted to) Bacteria, since such motifs are typically bound by factors containing a Helix-Turn-Helix domain. We evaluated footprint discovery in 368 Escherichia coli K12 genes with annotated sites, under 40 different combinations of parameters (taxonomical level, background model, organism-specific filtering, operon inference). Motifs are assessed both at the levels of correctness and significance. We further report a detailed analysis of 181 bacterial orthologs of the LexA repressor. Distinct motifs are detected at various taxonomical levels, including the 7 previously characterized taxon-specific motifs. In addition, we highlight a significantly stronger conservation of half-motifs in Actinobacteria, relative to Firmicutes, suggesting an intermediate state in specificity switching between the two Gram-positive phyla, and thereby revealing the on-going evolution of LexA auto-regulation. The footprint discovery method proposed here shows excellent results with E. coli and can readily be extended to predict cis-acting regulatory signals and propose testable hypotheses in bacterial genomes for which nothing is known about regulation.
Rapid Surface Detection of CO2 Leaks from Geologic Sequestration Sites
NASA Astrophysics Data System (ADS)
Moriarty, D. M.; Krevor, S. C.; Benson, S. M.
2013-12-01
Carbon sequestration is becoming a viable option for global CO2 mitigation but effective monitoring methods are needed assure the carbon dioxide stays underground. Above surface monitoring using a mobile gas analyzer is one such method (e.g. Krevor et al., 2010). The Picarro gas analyzer uses wavelength-scanned cavity ring down spectroscopy to accurately identify concentrations of various atmospheric gases including their isotopic composition. These measurements can then be used for anomaly (leak) detection and source attribution. Leaks are detected by anomalous absolute concentration of CO2 and anomalous δ13C values. Source attribution is determined by the isotopic concentrations of the identified leaking gas. To distinguish between noise from ambient signals and leaks, a method based on mixing ratios has been developed. A newly acquired data set presented here has been collected from a 3.7km2 area with naturally occurring CO2 springs near Green River, Utah. All of the areas of known leakage were readily detected using this method along with several other areas that showed significant signs of leakage. In addition, testing on the Stanford campus has shown that this method is sensitive enough to distinguish between open fields and roadways. Another data set is being collected at Montana State University at the ZERT monitoring test site where an artificial leak has been created for the purpose of testing leak detection and quantification methods. Data collected from this site are being used for (1) assessing of detection levels and how they depend on environmental parameters such as wind speed, and acquisition variables such as sample rate and traverse speed, (2) optimizing acquisition parameters to increase detection levels and increase confidence in leak detection, (3) evaluating the potential for quantifying the magnitude of the leak and (4) spatial data analysis to identify the most probable leak locations.
Rastall, Andrew C; Getting, Dominic; Goddard, Jon; Roberts, David R; Erdinger, Lothar
2006-07-01
Some anthropogenic pollutants posses the capacity to disrupt endogenous control of developmental and reproductive processes in aquatic biota by activating estrogen receptors. Many anthropogenic estrogen receptor agonists (ERAs) are hydrophobic and will therefore readily partition into the abiotic organic carbon phases present in natural waters. This partitioning process effectively reduces the proportion of ERAs readily available for bioconcentration by aquatic biota. Results from some studies have suggested that for many aquatic species, bioconcentration of the freely-dissolved fraction may be the principal route of uptake for hydrophobic pollutants with logarithm n-octanol/water partition coefficient (log Kow) values less than approximately 6.0, which includes the majority of known anthropogenic ERAs. The detection and identification of freely-dissolved readily bioconcentratable ERAs is therefore an important aspect of exposure and risk assessment. However, most studies use conventional techniques to sample total ERA concentrations and in doing so frequently fail to account for bioconcentration of the freely-dissolved fraction. The aim of the current study was to couple the biomimetic sampling properties of semipermeable membrane devices (SPMDs) to a bioassay-directed chemical analysis (BDCA) scheme for the detection and identification of readily bioconcentratable ERAs in surface waters. SPMDs were constructed and deployed at a number of sites in Germany and the UK. Following the dialytic recovery of target compounds and size exclusion chromatographic cleanup, SPMD samples were fractionated using a reverse-phase HPLC method calibrated to provide an estimation of target analyte log Kow. A portion of each HPLC fraction was then subjected to the yeast estrogen screen (YES) to determine estrogenic potential. Results were plotted in the form of 'estrograms' which displayed profiles of estrogenic potential as a function of HPLC retention time (i.e. hydrophobicity) for each of the samples. Where significant activity was elicited in the YES, the remaining portion of the respective active fraction was subjected to GC-MS analysis in an attempt to identify the ERAs present. Estrograms from each of the field samples showed that readily bioconcentratable ERAs were present at each of the sampling sites. Estimated log Kow values for the various active fractions ranged from 1.92 to 8.63. For some samples, estrogenic potential was associated with a relatively narrow range of log Kow values whilst in others estrogenic potential was more widely distributed across the respective estrograms. ERAs identified in active fractions included some benzophenones, various nonylphenol isomers, benzyl butyl phthalate, dehydroabietic acid, sitosterol, 3-(4-methylbenzylidine)camphor (4-MBC) and 6-acetyl-1,1,2,4,4,7-hexamethyltetralin (AHTN). Other tentatively identified compounds which may have contributed to the observed YES activity included various polycyclic aromatic hydrocarbons (PAHs) and their alkylated derivatives, methylated benzylphenols, various alkyl-phenols and dialkylphenols. However, potential ERAs present in some active fractions remain unidentified. Our results show that SPMD-YES-based BDCA can be used to detect and identify readily bioconcentratable ERAs in surface waters. As such, this biomimetic approach can be employed as an alternative to conventional methodologies to provide investigators with a more environmentally relevant insight into the distribution and identity of ERAs in surface waters. The use of alternative bioassays also has the potential to expand SPMD-based BDCA to include a wide range of toxicological endpoints. Improvements to the analytical methodology used to identify ERAs or other target compounds in active fractions in the current study could greatly enhance the applicability of the methodology to risk assessment and monitoring programmes.
Detecting T-cell reactivity to whole cell vaccines
Brusic, Ana; Hainz, Ursula; Wadleigh, Martha; Neuberg, Donna; Su, Mei; Canning, Christine M.; DeAngelo, Daniel J.; Stone, Richard M.; Lee, Jeng-Shin; Mulligan, Richard C.; Ritz, Jerome; Dranoff, Glenn; Sasada, Tetsuro; Wu, Catherine J.
2012-01-01
BCR-ABL+ K562 cells hold clinical promise as a component of cancer vaccines, either as bystander cells genetically modified to express immunostimulatory molecules, or as a source of leukemia antigens. To develop a method for detecting T-cell reactivity against K562 cell-derived antigens in patients, we exploited the dendritic cell (DC)-mediated cross-presentation of proteins generated from apoptotic cells. We used UVB irradiation to consistently induce apoptosis of K562 cells, which were then fed to autologous DCs. These DCs were used to both stimulate and detect antigen-specific CD8+ T-cell reactivity. As proof-of-concept, we used cross-presented apoptotic influenza matrix protein-expressing K562 cells to elicit reactivity from matrix protein-reactive T cells. Likewise, we used this assay to detect increased anti-CML antigen T-cell reactivity in CML patients that attained long-lasting clinical remissions following immunotherapy (donor lymphocyte infusion), as well as in 2 of 3 CML patients vaccinated with lethally irradiated K562 cells that were modified to secrete high levels of granulocyte macrophage colony-stimulating factor (GM-CSF). This methodology can be readily adapted to examine the effects of other whole tumor cell-based vaccines, a scenario in which the precise tumor antigens that stimulate immune responses are unknown. PMID:23170257
Observation of force-detected nuclear magnetic resonance in a homogeneous field
Madsen, L. A.; Leskowitz, G. M.; Weitekamp, D. P.
2004-01-01
We report the experimental realization of BOOMERANG (better observation of magnetization, enhanced resolution, and no gradient), a sensitive and general method of magnetic resonance. The prototype millimeter-scale NMR spectrometer shows signal and noise levels in agreement with the design principles. We present 1H and 19F NMR in both solid and liquid samples, including time-domain Fourier transform NMR spectroscopy, multiple-pulse echoes, and heteronuclear J spectroscopy. By measuring a 1H-19F J coupling, this last experiment accomplishes chemically specific spectroscopy with force-detected NMR. In BOOMERANG, an assembly of permanent magnets provides a homogeneous field throughout the sample, while a harmonically suspended part of the assembly, a detector, is mechanically driven by spin-dependent forces. By placing the sample in a homogeneous field, signal dephasing by diffusion in a field gradient is made negligible, enabling application to liquids, in contrast to other force-detection methods. The design appears readily scalable to μm-scale samples where it should have sensitivity advantages over inductive detection with microcoils and where it holds great promise for application of magnetic resonance in biology, chemistry, physics, and surface science. We briefly discuss extensions of the BOOMERANG method to the μm and nm scales. PMID:15326302
A numerical study of defect detection in a plaster dome ceiling using structural acoustics.
Bucaro, J A; Romano, A J; Valdivia, N; Houston, B H; Dey, S
2009-07-01
A numerical study is carried out to evaluate the effectiveness of using measured surface displacements resulting from acoustic speaker excitation to detect and localize flaws in a domed, plaster ceiling. The response of the structure to an incident acoustic pressure is obtained at four frequencies between 100 and 400 Hz using a parallel h-p structural acoustic finite element-based code. Three ceiling conditions are modeled: the pristine ceiling considered rigidly attached to the domed-shape support, partial detachment of a segment of the plaster layer from the support, and an interior pocket of plaster deconsolidation modeled as a heavy fluid. Spatial maps of the normal displacement resulting from speaker excitation are interpreted with the help of predictions based on static analysis. It is found that acoustic speaker excitation can provide displacement levels readily detected by commercially available laser Doppler vibrometer systems. Further, it is concluded that for 1 in. thick plaster layers, detachment sizes as small as 4 cm are detectable by direct observation of the measured displacement maps. Finally, spatial structure differences are observed in the displacement maps beneath the two defect types, which may provide a wavenumber-based feature useful for distinguishing plaster detachment from other defects such as deconsolidation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Nested. 29.6027 Section 29.6027 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... which cannot be readily detected upon inspection because of the way the lot is packed or arranged. (See...
40 CFR 796.2750 - Sediment and soil adsorption isotherm.
Code of Federal Regulations, 2014 CFR
2014-07-01
... are highly reproducible. The test provides excellent quantitative data readily amenable to statistical... combination of methods suitable for the identification and quantitative detection of the parent test chemical... quantitative analysis of the parent chemical. (3) Amount of parent test chemical applied, the amount recovered...
40 CFR 796.2750 - Sediment and soil adsorption isotherm.
Code of Federal Regulations, 2013 CFR
2013-07-01
... highly reproducible. The test provides excellent quantitative data readily amenable to statistical... combination of methods suitable for the identification and quantitative detection of the parent test chemical... quantitative analysis of the parent chemical. (3) Amount of parent test chemical applied, the amount recovered...
40 CFR 796.2750 - Sediment and soil adsorption isotherm.
Code of Federal Regulations, 2012 CFR
2012-07-01
... highly reproducible. The test provides excellent quantitative data readily amenable to statistical... combination of methods suitable for the identification and quantitative detection of the parent test chemical... quantitative analysis of the parent chemical. (3) Amount of parent test chemical applied, the amount recovered...
Adeno-associated virus rep protein synthesis during productive infection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Redemann, B.E.; Mendelson, E.; Carter, B.J.
1989-02-01
Adeno-associated virus (AAV) Rep proteins mediate viral DNA replication and can regulate expression from AAV genes. The authors studied the kinetics of synthesis of the four Rep proteins, Rep78, Rep68, Rep52, and Rep40, during infection of human 293 or KB cells with AAV and helper adenovirus by in vivo labeling with (/sup 35/S)methionine, immunoprecipitation, and immunoblotting analyses. Rep78 and Rep52 were readily detected concomitantly with detection of viral monomer duplex DNA replicating about 10 to 12 h after infection, and Rep68 and Rep40 were detected 2 h later. Rep78 and Rep52 were more abundant than Rep68 and Rep40 owing tomore » a higher synthesis rate throughout the infectious cycle. In some experiments, very low levels of Rep78 could be detected as early as 4 h after infection. The synthesis rates of Rep proteins were maximal between 14 and 24 h and then decreased later after infection. Isotopic pulse-chase experiments showed that each of the Rep proteins was synthesized independently and was stable for at least 15 h. A slower-migrating, modified form of Rep78 was identified late after infection. AAV capsid protein synthesis was detected at 10 to 12 h after infection and also exhibited synthesis kinetics similar to those of the Rep proteins. AAV DNA replication showed at least two clearly defined stages. Bulk duplex replicating DNA accumulation began around 10 to 12 h and reached a maximum level at about 20 h when Rep and capsid protein synthesis was maximal. Progeny single-stranded DNA accumulation began about 12 to 13 h, but most of this DNA accumulated after 24 h when Rep and capsid protein synthesis had decreased.« less
Prion-Seeding Activity in Cerebrospinal Fluid of Deer with Chronic Wasting Disease
Haley, Nicholas J.; Van de Motter, Alexandra; Carver, Scott; Henderson, Davin; Davenport, Kristen; Seelig, Davis M.; Mathiason, Candace; Hoover, Edward
2013-01-01
Transmissible spongiform encephalopathies (TSEs), or prion diseases, are a uniformly fatal family of neurodegenerative diseases in mammals that includes chronic wasting disease (CWD) of cervids. The early and ante-mortem identification of TSE-infected individuals using conventional western blotting or immunohistochemistry (IHC) has proven difficult, as the levels of infectious prions in readily obtainable samples, including blood and bodily fluids, are typically beyond the limits of detection. The development of amplification-based seeding assays has been instrumental in the detection of low levels of infectious prions in clinical samples. In the present study, we evaluated the cerebrospinal fluid (CSF) of CWD-exposed (n=44) and naïve (n=4) deer (n=48 total) for CWD prions (PrPd) using two amplification assays: serial protein misfolding cyclic amplification with polytetrafluoroethylene beads (sPMCAb) and real-time quaking induced conversion (RT-QuIC) employing a truncated Syrian hamster recombinant protein substrate. Samples were evaluated blindly in parallel with appropriate positive and negative controls. Results from amplification assays were compared to one another and to obex immunohistochemistry, and were correlated to available clinical histories including CWD inoculum source (e.g. saliva, blood), genotype, survival period, and duration of clinical signs. We found that both sPMCAb and RT-QuIC were capable of amplifying CWD prions from cervid CSF, and results correlated well with one another. Prion seeding activity in either assay was observed in approximately 50% of deer with PrPd detected by IHC in the obex region of the brain. Important predictors of amplification included duration of clinical signs and time of first tonsil biopsy positive results, and ultimately the levels of PrPd identified in the obex by IHC. Based on our findings, we expect that both sPMCAb and RT-QuIC may prove to be useful detection assays for the detection of prions in CSF. PMID:24282599
Reaching the quantum limit of sensitivity in electron spin resonance
Bienfait, A.; Pla, J. J.; Kubo, Y.; ...
2015-12-14
The detection and characterization of paramagnetic species by electron spin resonance (ESR) spectroscopy is widely used throughout chemistry, biology and materials science, from in vivo imaging to distance measurements in spin-labelled proteins. ESR relies on the inductive detection of microwave signals emitted by the spins into a coupled microwave resonator during their Larmor precession. However, such signals can be very small, prohibiting the application of ESR at the nanoscale (for example, at the single-cell level or on individual nanoparticles). Here in this work, using a Josephson parametric microwave amplifier combined with high-quality-factor superconducting microresonators cooled at millikelvin temperatures, we improvemore » the state-of-the-art sensitivity of inductive ESR detection by nearly four orders of magnitude. We demonstrate the detection of 1,700 bismuth donor spins in silicon within a single Hahn echo with unit signal-to-noise ratio, reduced to 150 spins by averaging a single Carr-Purcell-Meiboom-Gill sequence. This unprecedented sensitivity reaches the limit set by quantum fluctuations of the electromagnetic field instead of thermal or technical noise, which constitutes a novel regime for magnetic resonance. In conclusion, the detection volume of our resonator is ~0.02nl, and our approach can be readily scaled down further to improve sensitivity, providing a new versatile toolbox for ESR at the nanoscale.« less
Belshaw, Nigel J; Elliott, Giles O; Williams, Elizabeth A; Bradburn, David M; Mills, Sarah J; Mathers, John C; Johnson, Ian T
2004-09-01
Hypermethylation of cytosine residues in the CpG islands of tumor suppressor genes is a key mechanism of colorectal carcinogenesis. Detection and quantification of CpG island methylation in human DNA isolated from stools might provide a novel strategy for the detection and investigation of colorectal neoplasia. To explore the feasibility of this approach, colorectal biopsies and fecal samples were obtained from 32 patients attending for colonoscopy or surgery, who were found to have adenomatous polyps, colorectal cancer, or no evidence of neoplasia. A further 18 fecal samples were obtained from healthy volunteers, with no bowel symptoms. Isolated DNA was modified with sodium bisulfite and analyzed by methylation-specific PCR and combined bisulfite restriction analysis for CpG island methylation of ESR1, MGMT, HPP1, p16(INK4a), APC, and MLH1. CpG island methylation was readily detectable in both mucosal and fecal DNA with methylation-specific PCR. Using combined bisulfite restriction analysis, it was established that, in volunteers from whom biopsies were available, the levels of methylation at two CpG sites within ESR1 assayed using fecal DNA were significantly correlated with methylation in DNA from colorectal mucosa. Thus, noninvasive techniques can be used to obtain quantitative information about the level of CpG island methylation in human colorectal mucosa. The methods described here could be applied to a much expanded range of genes and may be valuable both for screening purposes and to provide greater insight into the functional consequences of epigenetic changes in the colorectal mucosa of free-living individuals.
Barbosa, M S; Wettstein, F O
1987-01-01
Cottontail rabbit papillomavirus (CRPV) early proteins are present at very low levels in virus-induced tumors and cannot be detected by immunological methods. Furthermore, cells in culture are not readily transformed by the virus. To overcome these difficulties in identifying and characterizing the putative transforming protein(s) coded by the E6 open reading frame, the early cottontail rabbit papillomavirus region was expressed under the control of the late simian virus 40 promoter. Mapping of the transcripts in transiently transfected COS-7 cells indicated that transcription was initiated in the late region of simian virus 40. Two E6-coded polypeptides were identified, representing translation products initiated at the first and second AUG codons. Images PMID:3039182
Ding, Liang; Bond, Alan M; Zhai, Jianping; Zhang, Jie
2013-10-03
Nanoparticles with desirable properties not exhibited by the bulk material can be readily synthesized because of rapid technological developments in the fields of materials science and nanotechnology. In particular their highly attractive electrochemical properties and electrocatalytic activity have facilitated achievement of the high level of signal amplification needed for the development of ultrasensitive electrochemical affinity biosensors for the detection of proteins and DNA. This review article explains the basic principles of nanoparticle based electrochemical biosensors, highlights the recent advances in the development of nanoparticle based signal amplification strategies, and provides a critical assessment of the likely drawbacks associated with each strategy. Finally, future perspectives for achieving advanced signal simplification in nanoparticles based biosensors are considered. Copyright © 2013 Elsevier B.V. All rights reserved.
Determination of selected azaarenes in water by bonded-phase extraction and liquid chromatography
Steinheimer, T.R.; Ondrus, M.G.
1986-01-01
A method for the rapid and simple quantitative determination of quinoline, isoquinoline, and five selected three-ring azaarenes in water has been developed. The azaarene fraction is separated from its carbon analogues on n-octadecyl packing material by edition with acidified water/acetonitrile. Concentration as great as 1000-fold is achieved readily. Instrumental analysis involves high-speed liquid chromatography on flexible-walled, wide-bore columns with fluorescence and ultraviolet detection at several wavelengths employing filter photometers in series. Method-validation data is provided as azaarene recovery efficiency from fortified samples. Distilled water, river water, contaminated ground water, and secondary-treatment effluent have been tested. Recoveries at part-per-billion levels are nearly quantitative for the three-ring compounds, but they decrease for quinoline and isoquinoline. ?? 1986 American Chemical Society.
Article surveillance magnetic marker having an hysteresis loop with large Barkhausen discontinuities
Humphrey, Floyd B.
1987-01-01
A marker for an electronic article surveillance system is disclosed comprising a body of magnetic material with retained stress and having a magnetic hysteresis loop with a large Barkhausen discontinuity such that, upon exposure of the marker to an external magnetic field whose field strength in the direction opposing the instantaneous magnetic polarization of the marker exceeds a predetermined threshold value, there results a regenerative reversal of the magnetic polarization of the marker. An electronic article surveillance system and a method utilizing the marker are also disclosed. Exciting the marker with a low frequency and low field strength, so long as the field strength exceeds the low threshold level for the marker, causes a regenerative reversal of magnetic polarity generating a harmonically rich pulse that is readily detected and easily distinguished.
Borkowski, C J
1954-01-19
This pulse-type survey instrument is suitable for readily detecting {alpha} particles in the presence of high {beta} and {gamma} backgrounds. The instruments may also be used to survey for neutrons, {beta} particles and {gamma} rays by employing suitably designed interchangeable probes and selecting an operating potential to correspond to the particular probe.
Low temperature isothermal pyrolysis of cellulose
A. Broido; M. Weinstein
1971-01-01
By providing continuous weight measurement, thermogravimetry, even for isothermal experiments, offers a major advantage over the classical methods of determining weight-change curves in complex pyrolysis reactions. Thus, even minor weight changes, readily detectable on a continuous record, furnish clues concerning the reaction sequences and indicate conditions under...
Corral Monitoring System assessment results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filby, E.E.; Haskel, K.J.
1998-03-01
This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitoredmore » as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.« less
Jenkins, J M; Doyle, L R; Cullers, D K
1996-02-01
The photometric detection of extrasolar planets by transits in eclipsing binary systems can be significantly improved by cross-correlating the observational light curves with synthetic models of possible planetary transit features, essentially a matched filter approach. We demonstrate the utility and application of this transit detection algorithm for ground-based detections of terrestrial-sized (Earth-to-Neptune radii) extrasolar planets in the dwarf M-star eclipsing binary system CM Draconis. Preliminary photometric observational data of this system demonstrate that the observational noise is well characterized as white and Gaussian at the observational time steps required for precision photometric measurements. Depending on planet formation scenarios, terrestrial-sized planets may form quite close to this low-luminosity system. We demonstrate, for example, that planets as small as 1.4 Earth radii with periods on the order of a few months in the CM Draconis system could be detected at the 99.9% confidence level in less than a year using 1-m class telescopes from the ground. This result contradicts commonly held assumptions limiting present ground-based efforts to, at best, detections of gas giant planets after several years of observation. This method can be readily extended to a number of other larger star systems with the utilization of larger telescopes and longer observing times. Its extension to spacecraft observations should also allow the determination of the presence of terrestrial-sized planets in nearly 100 other known eclipsing binary systems.
NASA Technical Reports Server (NTRS)
Jenkins, J. M.; Doyle, L. R.; Cullers, D. K.
1996-01-01
The photometric detection of extrasolar planets by transits in eclipsing binary systems can be significantly improved by cross-correlating the observational light curves with synthetic models of possible planetary transit features, essentially a matched filter approach. We demonstrate the utility and application of this transit detection algorithm for ground-based detections of terrestrial-sized (Earth-to-Neptune radii) extrasolar planets in the dwarf M-star eclipsing binary system CM Draconis. Preliminary photometric observational data of this system demonstrate that the observational noise is well characterized as white and Gaussian at the observational time steps required for precision photometric measurements. Depending on planet formation scenarios, terrestrial-sized planets may form quite close to this low-luminosity system. We demonstrate, for example, that planets as small as 1.4 Earth radii with periods on the order of a few months in the CM Draconis system could be detected at the 99.9% confidence level in less than a year using 1-m class telescopes from the ground. This result contradicts commonly held assumptions limiting present ground-based efforts to, at best, detections of gas giant planets after several years of observation. This method can be readily extended to a number of other larger star systems with the utilization of larger telescopes and longer observing times. Its extension to spacecraft observations should also allow the determination of the presence of terrestrial-sized planets in nearly 100 other known eclipsing binary systems.
Comparing methods of detecting alcohol-related emergency department presentations.
Indig, D; Copeland, J; Conigrave, K M
2009-08-01
To assess the strengths and limitations of different methods for detecting alcohol-related emergency department (ED) presentations and to compare the characteristics of patients who present to the ED with an alcohol-related presentation with ED patients who are found to be risky drinkers by a questionnaire. Survey at two Sydney Australia ED over four weekends of 389 patients. Alcohol-related presentations were identified using a range of methods and were compared with presentations in ED patients who reported risky drinking using the alcohol use disorders identification test (AUDIT). Overall, 20% of ED patients had alcohol-related presentations and 28% were identified as risky drinkers by AUDIT. Diagnostic codes detected only 7% of all alcohol-related ED presentations, compared with 34% detected by nursing triage text, 60% by medical record audits and 69% by self-report. Among risky drinkers, just over half (51%) were not attending for an alcohol-related reason, whereas among alcohol-related ED presentations, nearly a third (31%) were not identified as risky drinkers by AUDIT. Not all patients with an alcohol-related ED presentation usually drink at risky levels, nor do all risky drinkers present to the ED for an alcohol-related reason. The use of routinely recorded nursing triage text detects over a third of alcohol-related ED presentations with no additional burden on busy clinicians. As these data are potentially readily accessible, further research is needed to evaluate their validity for the detection of alcohol-related ED presentations.
Analysis of exhaled breath by laser detection
NASA Astrophysics Data System (ADS)
Thrall, Karla D.; Toth, James J.; Sharpe, Steven W.
1996-04-01
The goal of our work is two fold: (1) to develop a portable rapid laser based breath analyzer for monitoring metabolic processes, and (2) predict these metabolic processes through physiologically based pharmacokinetic (PBPK) modeling. Small infrared active molecules such as ammonia, carbon monoxide, carbon dioxide, methane and ethane are present in exhaled breath and can be readily detected by laser absorption spectroscopy. In addition, many of the stable isotopomers of these molecules can be accurately detected, making it possible to follow specific metabolic processes. Potential areas of applications for this technology include the diagnosis of certain pathologies (e.g. Helicobacter Pylori infection), detection of trauma due to either physical or chemical causes and monitoring nutrient uptake (i.e., malnutrition). In order to understand the origin and elucidate the metabolic processes associated with these small molecules, we are employing physiologically based pharmacokinetic (PBPK) models. A PBPK model is founded on known physiological processes (i.e., blood flow rates, tissue volumes, breathing rate, etc.), chemical-specific processes (i.e., tissue solubility coefficients, molecular weight, chemical density, etc.), and on metabolic processes (tissue site and rate of metabolic biotransformation). Since many of these processes are well understood, a PBPK model can be developed and validated against the more readily available experimental animal data, and then by extrapolating the parameters to apply to man, the model can predict chemical behavior in humans.
Binnie, N R; Kawimbe, B M; Papachrysostomou, M; Clare, N; Smith, A N
1991-02-01
Two non-invasive anal plug electrodes of similar size have been compared, one with the electrode plates orientated circularly in the anal canal and the other with the plates in the long axis of the anal canal. There was a significant increase in the amplitude in the EMG signals recorded at rest and during squeeze from the external anal sphincter with a longitudinally placed electrode in 117 patients. Inappropriate contraction of the external anal sphincter when straining at stool was more readily detected using the longitudinal electrode in 52 patients investigated for intractable constipation. The longitudinal electrode detected the amplitude of the response to the elicitation of a pudeno-anal reflex more readily than the circular electrode. When in 12 of the 117 the pudeno-anal reflex EMG signal was either absent or not detected with the circumferential plug electrode, the longitudinal electrode detected the presence of a low amplitude response in 11 of these. When the non-invasive longitudinal electrode was compared to invasive fine wire stainless steel electrodes, a correlation was found for external anal sphincter resting EMG (r = 0.99, p less than 0.01), voluntary squeeze EMG (r = 0.99, p less than 0.001) and strain EMG (r = 0.91, p less than 0.01). The longitudinal anal plug electrode thus facilitates surface acquisition of EMG activity.
Highly Selective and Rapid Breath Isoprene Sensing Enabled by Activated Alumina Filter.
van den Broek, Jan; Güntner, Andreas T; Pratsinis, Sotiris E
2018-03-23
Isoprene is a versatile breath marker for noninvasive monitoring of high blood cholesterol levels as well as for influenza, end-stage renal disease, muscle activity, lung cancer, and liver disease with advanced fibrosis. Its selective detection in complex human breath by portable devices (e.g., metal-oxide gas sensors), however, is still challenging. Here, we present a new filter concept based on activated alumina powder enabling fast and highly selective detection of isoprene at the ppb level and high humidity. The filter contains high surface area adsorbents that retain hydrophilic compounds (e.g., ketones, alcohols, ammonia) representing major interferants in breath while hydrophobic isoprene is not affected. As a proof-of-concept, filters of commercial activated alumina powder are combined with highly sensitive but rather nonspecific, nanostructured Pt-doped SnO 2 sensors. This results in fast (10 s) measurement of isoprene down to 5 ppb at 90% relative humidity with outstanding selectivity (>100) to breath-relevant acetone, ammonia, ethanol, and methanol, superior to state-of-the-art isoprene sensors. Most importantly, when exposed continuously to simulated breath mixtures (four analytes) for 8 days, this filter-sensor system showed stable performance. It can be incorporated readily into a portable breath isoprene analyzer promising for simple-in-use monitoring of blood cholesterol or other patho/physiological conditions.
NASA Technical Reports Server (NTRS)
Levine, Joel S.; Summers, Michael E.
2008-01-01
In the early history of Mars, volcanic activity associated with the formation of the Tharsis ridge produced a very large amount of atmospheric SO2--on the order of a bar of atmospheric SO2. In the present-day atmosphere of Mars, the lifetime of SO2 is relatively short with a lifetime of less than a day. The short lifetime of SO2 in the present Mars atmosphere makes the production of significant levels of H2SO4 very difficult since the SO2 may be destroyed by various chemical and photochemical processes before the SO2 can be converted to H2SO4. However, photochemical calculations performed and described here, indicate that enhanced atmospheric levels of CO2 in the early atmosphere of Mars resulted in a significantly enhanced atmospheric lifetime for SO2 up to several years. With a significantly enhanced atmospheric lifetime, SO2 could readily form large amounts of H2SO4, which precipitated out of the atmosphere in the form of droplets. The precipitated H2SO4 then reacted with potential surface carbonates, destroying the carbonates and resulting in the abundant and widespread distribution of sulfates on the surface of Mars as detected by recent Mars missions.
Cavity transport effects in generator-collector electrochemical analysis of nitrobenzene.
Lewis, Grace E M; Dale, Sara E C; Kasprzyk-Hordern, Barbara; Lubben, Anneke T; Barnes, Edward O; Compton, Richard G; Marken, Frank
2014-09-21
Two types of generator-collector electrode systems, (i) a gold-gold interdigitated microband array and (ii) a gold-gold dual-plate microtrench, are compared for nitrobenzene electroanalysis in aerated aqueous 0.1 M NaOH. The complexity of the nitrobenzene reduction in conjunction with the presence of ambient levels of oxygen in the analysis solution provide a challenging problem in which feedback-amplified generator-collector steady state currents provide the analytical signal. In contrast to the more openly accessible geometry of the interdigitated array electrode, where the voltammetric response for nitrobenzene is less well-defined and signals drift, the voltammetric response for the cavity-like microtrench electrode is stable and readily detectable at 1 μM level. Both types of electrode show oxygen-enhanced low concentration collector current responses due to additional feedback via reaction intermediates. The observations are rationalised in terms of a "cavity transport coefficient" which is beneficial in the dual-plate microtrench, where oxygen interference effects are suppressed and the analytical signal is amplified and stabilised.
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics.
Kim, Jayoung; Imani, Somayeh; de Araujo, William R; Warchall, Julian; Valdés-Ramírez, Gabriela; Paixão, Thiago R L C; Mercier, Patrick P; Wang, Joseph
2015-12-15
This article demonstrates an instrumented mouthguard capable of non-invasively monitoring salivary uric acid (SUA) levels. The enzyme (uricase)-modified screen printed electrode system has been integrated onto a mouthguard platform along with anatomically-miniaturized instrumentation electronics featuring a potentiostat, microcontroller, and a Bluetooth Low Energy (BLE) transceiver. Unlike RFID-based biosensing systems, which require large proximal power sources, the developed platform enables real-time wireless transmission of the sensed information to standard smartphones, laptops, and other consumer electronics for on-demand processing, diagnostics, or storage. The mouthguard biosensor system offers high sensitivity, selectivity, and stability towards uric acid detection in human saliva, covering the concentration ranges for both healthy people and hyperuricemia patients. The new wireless mouthguard biosensor system is able to monitor SUA level in real-time and continuous fashion, and can be readily expanded to an array of sensors for different analytes to enable an attractive wearable monitoring system for diverse health and fitness applications. Copyright © 2015 Elsevier B.V. All rights reserved.
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, Jayoung; Imani, Somayeh; de Araujo, William R.; Warchall, Julian; Valdés-Ramírez, Gabriela; Paixão, Thiago R.L.C.; Mercier, Patrick P.; Wang, Joseph
2016-01-01
This article demonstrates an instrumented mouthguard capable of non-invasively monitoring salivary uric acid (SUA) levels. The enzyme (uricase)-modified screen printed electrode system has been integrated onto a mouthguard platform along with anatomically-miniaturized instrumentation electronics featuring a potentiostat, microcontroller, and a Bluetooth Low Energy (BLE) transceiver. Unlike RFID-based biosensing systems, which require large proximal power sources, the developed platform enables real-time wireless transmission of the sensed information to standard smartphones, laptops, and other consumer electronics for on-demand processing, diagnostics, or storage. The mouthguard biosensor system offers high sensitivity, selectivity, and stability towards uric acid detection in human saliva, covering the concentration ranges for both healthy people and hyperuricemia patients. The new wireless mouthguard biosensor system is able to monitor SUA level in real-time and continuous fashion, and can be readily expanded to an array of sensors for different analytes to enable an attractive wearable monitoring system for diverse health and fitness applications. PMID:26276541
Krolewiecki, Alejandro J; Koukounari, Artemis; Romano, Miryam; Caro, Reynaldo N; Scott, Alan L; Fleitas, Pedro; Cimino, Ruben; Shiff, Clive J
2018-06-01
For epidemiological work with soil transmitted helminths the recommended diagnostic approaches are to examine fecal samples for microscopic evidence of the parasite. In addition to several logistical and processing issues, traditional diagnostic approaches have been shown to lack the sensitivity required to reliably identify patients harboring low-level infections such as those associated with effective mass drug intervention programs. In this context, there is a need to rethink the approaches used for helminth diagnostics. Serological methods are now in use, however these tests are indirect and depend on individual immune responses, exposure patterns and the nature of the antigen. However, it has been demonstrated that cell-free DNA from pathogens and cancers can be readily detected in patient's urine which can be collected in the field, filtered in situ and processed later for analysis. In the work presented here, we employ three diagnostic procedures-stool examination, serology (NIE-ELISA) and PCR-based amplification of parasite transrenal DNA from urine-to determine their relative utility in the diagnosis of S. stercoralis infections from 359 field samples from an endemic area of Argentina. Bayesian Latent Class analysis was used to assess the relative performance of the three diagnostic procedures. The results underscore the low sensitivity of stool examination and support the idea that the use of serology combined with parasite transrenal DNA detection may be a useful strategy for sensitive and specific detection of low-level strongyloidiasis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Page, D.S.; Boehm, P.D.; Douglas, G.S.
Advanced hydrocarbon fingerprinting methods and improved analytical methods make possible the quantitative discrimination of the multiple sources of hydrocarbons in the benthic sediments of Prince William Sound (PWS) and the Gulf of Alaska. These methods measure an extensive range of polycyclic aromatic hydrocarbons (PAH) at detection levels that are as much as two orders of magnitude lower than those obtained by standard Environmental Protection Agency methods. Nineteen hundred thirty six subtidal sediment samples collected in the sound and the eastern Gulf of Alaska in 1989, 1990, and 1991 were analyzed. Fingerprint analyses of gas chromatography-mass spectrometry data reveal a naturalmore » background of petrogenic and biogenic PAH. Exxon Valdez crude, its weathering products, and diesel fuel refined from Alaska North Slope crude are readily distinguished from the natural seep petroleum background and from each other because of their distinctive PAH distributions. Mixing models were developed to calculate the PAH contributions from each source to each sediment sample. These calculations show that most of the seafloor in PWS contains no detectable hydrocarbons from the Exxon Valdez spill, although elevated concentrations of PAH from seep sources are widespread. In those areas where they were detected, spill hydrocarbons were generally a small increment to the natural petroleum hydrocarbon background. Low levels of Exxon Valdez crude residue were present in 1989 and again in 1990 in nearshore subtidal sediments off some shorelines that had been heavily oiled. By 1991 these crude residues were heavily degraded and even more sporadically distributed. 58 refs., 18 figs., 5 tabs.« less
The detection of infective protozoan parasites contained in large volume environmental samples represents a unique challenge in environmental parasitology. Compounding this problem is the fact that infective stages of many protozoan parasites do not readily replicate in media or ...
78 FR 39295 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-01
... standardized and readily accessible source of data, the CDC EHDI program developed a survey to be used annually... Detection and Intervention (EHDI) programs with quality improvement activities and provide information that... or the current system from the Directors of Speech and Language Programs in State Health and Welfare...
Detection of Feigned ADHD in College Students
ERIC Educational Resources Information Center
Sollman, Myriam J.; Ranseen, John D.; Berry, David T. R.
2010-01-01
Significant motivations and incentives exist for young-adult students to seek a diagnosis of attention-deficit/hyperactivity disorder (ADHD). With ADHD information readily accessible on the Internet, today's students are likely to be symptom educated prior to evaluation. This may result in false-positive diagnoses, particularly when students are…
Li, Dawei; Qu, Lulu; Zhai, Wenlei; Xue, Jinqun; Fossey, John S; Long, Yitao
2011-05-01
A novel facile method for on-site detection of substituted aromatic pollutants in water using thin layer chromatography (TLC) combined with surface-enhanced Raman spectroscopy (SERS) was explored. Various substituted aromatics in polluted water were separated by a convenient TLC protocol and then detected using a portable Raman spectrometer with the prepared silver colloids serving as SERS-active substrates. The effects of operating conditions on detection efficacy were evaluated, and the application of TLC-SERS to on-site detection of artificial and real-life samples of aromatics/polluted water was systematically investigated. It was shown that commercially available Si 60-F(254) TLC plates were suitable for separation and displayed low SERS background and good separation efficiency, 2 mM silver colloids, 20 mM NaCl (working as aggregating agent), 40 mW laser power, and 50 s intergration time were appropriate for the detection regime. Furthermore, qualitative and quantitative detection of most of substituted aromatic pollutants was found to be readily accomplished using the developed TLC-SERS technique, which compared well with GC-MS in terms of identification ability and detection accuracy, and a limit of detection (LOD) less than 0.2 ppm (even at ppb level for some analytes) could be achieved under optimal conditions. The results reveal that the presented convenient method could be used for the effective separation and detection of the substituted aromatic pollutants of water on site, thus reducing possible influences of sample transportation and contamination while shortening the overall analysis time for emergency and routine monitoring of the substituted aromatics/polluted water.
Landon, M.K.; Delin, G.N.
1995-01-01
Concentrations of atrazine and DEA generally were greater near the water table and decreased or were not detected in deeper wells. All of the samples in which atrazine and DEA were detected also had increased (greater than 3 mg/L) nitrate-N concentrations. However, not all samples with increased concentrations of nitrate-N had detections of atrazine or DEA. This likely indicates either that there were sources of nitrate-N other than cultivated fields on which both atrazine and nitrogen were applied or that nitrate-N reached ground water more readily than atrazine or DEA.
Feasibility study on the design of a probe for rectal cancer detection
NASA Technical Reports Server (NTRS)
Anselm, V. J.; Frazer, R. E.; Lecroisset, D. H.; Roseboro, J. A.; Smokler, M. I.
1977-01-01
Rectal examination techniques are considered in terms of detection capability, patient acceptance, and cost reduction. A review of existing clinical techniques are considered in terms of detection capability, patient acceptance, and cost reduction. A review of existing clinical techniques and of relevant aerospace technology included evaluation of the applicability of visual, thermal, ultrasound, and radioisotope modalities of examination. The desired improvements can be obtained by redesigning the proctosigmoidoscope to have reduced size, additional visibility, and the capability of readily providing a color photograph of the entire rectosigmoid mucosa in a single composite view.
Ward, Christopher S.; Eriksson, Pia; Izquierdo-Garcia, Jose L.; Brandes, Alissa H.; Ronen, Sabrina M.
2013-01-01
Histone deacetylase (HDAC) inhibitors have emerged as effective antineoplastic agents in the clinic. Studies from our lab and others have reported that magnetic resonance spectroscopy (MRS)-detectable phosphocholine (PC) is elevated following SAHA treatment, providing a potential noninvasive biomarker of response. Typically, elevated PC is associated with cancer while a decrease in PC accompanies response to antineoplastic treatment. The goal of this study was therefore to elucidate the underlying biochemical mechanism by which HDAC inhibition leads to elevated PC. We investigated the effect of SAHA on MCF-7 breast cancer cells using 13C MRS to monitor [1,2-13C] choline uptake and phosphorylation to PC. We found that PC synthesis was significantly higher in treated cells, representing 154±19% of control. This was within standard deviation of the increase in total PC levels detected by 31P MRS (129±7% of control). Furthermore, cellular choline kinase activity was elevated (177±31%), while cytidylyltransferase activity was unchanged. Expression of the intermediate-affinity choline transporter SLC44A1 and choline kinase α increased (144% and 161%, respectively) relative to control, as determined by mRNA microarray analysis with protein-level confirmation by Western blotting. Taken together, our findings indicate that the increase in PC levels following SAHA treatment results from its elevated synthesis. Additionally, the concentration of glycerophosphocholine (GPC) increased significantly with treatment to 210±45%. This is likely due to the upregulated expression of several phospholipase A2 (PLA2) isoforms, resulting in increased PLA2 activity (162±18%) in SAHA-treated cells. Importantly, the levels of total choline (tCho)-containing metabolites, comprised of choline, PC and GPC, are readily detectable clinically using 1H MRS. Our findings thus provide an important step in validating clinically translatable non-invasive imaging methods for follow-up diagnostics of HDAC inhibitor treatment. PMID:23626839
Low-Cost Charged-Coupled Device (CCD) Based Detectors for Shiga Toxins Activity Analysis.
Rasooly, Reuven; Prickril, Ben; Bruck, Hugh A; Rasooly, Avraham
2017-01-01
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of food-borne pathogens and their toxins. We describe a simple, low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemiluminescence, densitometry, and colorimetric assays. The portable battery-operated CCD-based detection system consists of four modules: (1) a webcam to measure and record light emission, (2) a sample plate to perform assays, (3) a light emitting diode (LED) for illumination, and (4) a portable computer to acquire and analyze images. To demonstrate the technology, we used a cell based assay for fluorescence detection of the activity of the food borne Shiga toxin type 2 (Stx2), differentiating between biologically active toxin and inactive toxin which is not a risk. The assay is based on Shiga toxin inhibition of cell protein synthesis measured through inhibition of the green fluorescent protein (GFP). In this assay, GFP emits light at 509 nm when excited with a blue LED equipped with a filter at 486 nm. The emitted light is then detected with a green filter at 535 nm. Toxin activity is measured through a reduction in the 509 nm emission. In this system the level of detection (LOD) for Stx2 was 0.1 pg/ml, similar to the LOD of commercial fluorometers. These results demonstrate the utility and potential of low cost detectors for toxin activity. This approach could be readily adapted to the detection of other food-borne toxins.
In situ spectroradiometric quantification of ERTS data
NASA Technical Reports Server (NTRS)
Yost, E. (Principal Investigator)
1972-01-01
The author has identified the following significant results. Additive color photographic analysis of ERTS-1 multispectral imagery indicates that the presence of soil moisture in playas (desert dry lakes) can be readily detected from space. Time sequence additive color presentations in which 600-700 nm bands taken at three successive 18-day cycles show that changes in soil moisture of playas with time can be detected as unique color signatures and can probably be quantitatively measured using photographic images of multispectral scanner data.
Does Litomosoides sigmodontis synthesize dimethylethanolamine from choline?
Houston, K M; Babayan, S A; Allen, J E; Harnett, W
2008-01-01
Juvenile female Litomosoides sigmodontis secrete a protein (Juv-p120) highly modified with dimethylethanolamine (DMAE). In an attempt to establish the source of this decoration worms were pulsed with [3H]-choline and [3H]-ethanolamine and the radio-isotope labelled products analysed. Both isotope labels were successfully taken up by the worms, as demonstrated by labelling of phospholipids with [3H]-choline, being predominantly incorporated into phosphatidylcholine and [3H]-ethanolamine into phosphatidylethanolamine. Isotope labelling of phosphatidylethanolamine was particularly striking with the worms taking up approximately 30 times as much labelled ethanolamine as choline. It was possible to detect faint labelling of Juv-p120 with [3H]-ethanolamine after prolonged exposure periods but, unlike the situation with the phospholipids, it was much more readily labelled with [3H]-choline. When pulsing with [3H]-ethanolamine it was also possible to detect isotope-labelled phosphatidylcholine, which may ultimately account for the low levels of labelling of Juv-p120. Overall our results raise the previously unconsidered but intriguing possibility that in L. sigmodontis, choline may be the precursor of DMAE.
Simon, Julianna C; Wang, Yak-Nam; Cunitz, Bryan W; Thiel, Jeffrey; Starr, Frank; Liu, Ziyue; Bailey, Michael R
2017-05-01
Bone demineralization, dehydration and stasis put astronauts at increased risk of forming kidney stones in space. The color-Doppler ultrasound "twinkling artifact," which highlights kidney stones with color, can make stones readily detectable with ultrasound; however, our previous results suggest twinkling is caused by microbubbles on the stone surface which could be affected by the elevated levels of carbon dioxide found on space vehicles. Four pigs were implanted with kidney stones and imaged with ultrasound while the anesthetic carrier gas oscillated between oxygen and air containing 0.8% carbon dioxide. On exposure of the pigs to 0.8% carbon dioxide, twinkling was significantly reduced after 9-25 min and recovered when the carrier gas returned to oxygen. These trends repeated when pigs were again exposed to 0.8% carbon dioxide followed by oxygen. The reduction of twinkling caused by exposure to elevated carbon dioxide may make kidney stone detection with twinkling difficult in current space vehicles. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cen, Longzhu; Zhang, Zijing; Zhang, Jiandong; Li, Shuo; Sun, Yifei; Yan, Linyu; Zhao, Yuan; Wang, Feng
2017-11-01
Circular polarization-entangled photons can be used to obtain an enhancement of the precision in a rotation measurement. In this paper, the method of entanglement transformation is used to produce NOON states in circular polarization from a readily generated linear polarization-entangled photon source. Detection of N -fold coincidences serves as the postselection and N -fold superoscillating fringes are obtained simultaneously. A parity strategy and conditional probabilistic statistics contribute to a better fringe, saturating the angle sensitivity to the Heisenberg limit. The impact of imperfect state preparation and detection is discussed both separately and jointly. For the separated case, the influence of each system imperfection is pronounced. For the joint case, the feasibility region for surpassing the standard quantum limit is given. Our work pushes the state preparation of circular polarization-entangled photons to the same level as that in the case of linear polarization. It is also confirmed that entanglement can be transformed into different frames for specific applications, serving as a useful scheme for using entangled sources.
Ishikawa, Muriel Y.; Wood, Lowell L.; Lougheed, Ronald W.; Moody, Kenton J.; Wang, Tzu-Fang
2004-05-25
A covert, gamma-ray "signature" is used as a "watermark" for property identification. This new watermarking technology is based on a unique steganographic or "hidden writing" digital signature, implemented in tiny quantities of gamma-ray-emitting radioisotopic material combinations, generally covertly emplaced on or within an object. This digital signature may be readily recovered at distant future times, by placing a sensitive, high energy-resolution gamma-ray detecting instrument reasonably precisely over the location of the watermark, which location may be known only to the object's owner; however, the signature is concealed from all ordinary detection means because its exceedingly low level of activity is obscured by the natural radiation background (including the gamma radiation naturally emanating from the object itself, from cosmic radiation and material surroundings, from human bodies, etc.). The "watermark" is used in object-tagging for establishing object identity, history or ownership. It thus may serve as an aid to law enforcement officials in identifying stolen property and prosecuting theft thereof. Highly effective, potentially very low cost identification-on demand of items of most all types is thus made possible.
Spatial cluster detection for repeatedly measured outcomes while accounting for residential history.
Cook, Andrea J; Gold, Diane R; Li, Yi
2009-10-01
Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information on study participants relocation, which most cluster detection statistics cannot. Application of these methods will be illustrated by the Home Allergens and Asthma prospective cohort study analyzing the relationship between environmental exposures and repeated measured outcome, occurrence of wheeze in the last 6 months, while taking into account mobile locations.
Accurate Differentiation of Carotenoid Pigments Using Flight Representative Raman Spectrometers
NASA Astrophysics Data System (ADS)
Malherbe, Cedric; Hutchinson, Ian B.; McHugh, Melissa; Ingley, Richard; Jehlička, Jan; Edwards, Howell G. M.
2017-04-01
Raman spectrometers will be utilized on two Mars rover missions, ExoMars and Mars 2020, in the near future, to search for evidence of life and habitable geological niches on Mars. Carotenoid pigments are recognized target biomarkers, and as they are highly active in Raman spectroscopy, they can be readily used to characterize the capabilities of space representative instrumentation. As part of the preparatory work being performed for the ExoMars mission, a gypsum crust colonized by microorganisms was interrogated with commercial portable Raman instruments and a flight representative Raman laser spectrometer. Four separate layers, each exhibiting different coloration resulting from specific halophilic microorganism activities within the gypsum crust, were studied by using two excitation wavelengths: 532 and 785 nm. Raman or fluorescence data were readily obtained during the present study. Gypsum, the main constituent of the crust, was detected with both excitation wavelengths, while the resonance Raman signal associated with carotenoid pigments was only detected with a 532 nm excitation wavelength. The fluorescence originating from bacteriochlorophyll a was found to overwhelm the Raman signal for the layer colonized by sulfur bacteria when interrogated with a 785 nm excitation wavelength. Finally, it was demonstrated that portable instruments and the prototype were capable of detecting a statistically significant difference in band positions of carotenoid signals between the sample layers.
Viral Susceptibility Range of the Fathead Minnow (Pimephales promelas) Poikilothermic Cell Line 1
Solis, Juan; Mora, Emilio C.
1970-01-01
The viral susceptibility range of a poikilothermic cell line derived from the fathead minnow (Pimephales promelas) (FHM) to infection by a number of homoiothermic viruses representing most of the presently recognized viral groups and a member of the psittacosis-lymphogranuloma-trachoma group of agents was studied. All infectious agents, except poliovirus types 1 and 3, infectious bursal agent, and an avian infectious bronchitis virus (IBV) strain, readily multiplied in the FHM cell culture system, producing a detectable cytopathic effect. Although inconclusive evidence was obtained with two other avian IBV strains, these results indicated the ability of the FHM cell culture system to readily support the propagation of a variety of cytopathogenic homoiothermic viral agents. PMID:5461163
Detecting and evaluating communities in complex human and biological networks
NASA Astrophysics Data System (ADS)
Morrison, Greg; Mahadevan, L.
2012-02-01
We develop a simple method for detecting the community structure in a network can by utilizing a measure of closeness between nodes. This approach readily leads to a method of coarse graining the network, which allows the detection of the natural hierarchy (or hierarchies) of community structure without appealing to an unknown resolution parameter. The closeness measure can also be used to evaluate the robustness of an individual node's assignment to its community (rather than evaluating only the quality of the global structure). Each of these methods in community detection and evaluation are illustrated using a variety of real world networks of either biological or sociological importance and illustrate the power and flexibility of the approach.
Causal Entropies – a measure for determining changes in the temporal organization of neural systems
Waddell, Jack; Dzakpasu, Rhonda; Booth, Victoria; Riley, Brett; Reasor, Jonathan; Poe, Gina; Zochowski, Michal
2009-01-01
We propose a novel measure to detect temporal ordering in the activity of individual neurons in a local network, which is thought to be a hallmark of activity-dependent synaptic modifications during learning. The measure, called Causal Entropy, is based on the time-adaptive detection of asymmetries in the relative temporal patterning between neuronal pairs. We characterize properties of the measure on both simulated data and experimental multiunit recordings of hippocampal neurons from the awake, behaving rat, and show that the metric can more readily detect those asymmetries than standard cross correlation-based techniques, especially since the temporal sensitivity of causal entropy can detect such changes rapidly and dynamically. PMID:17275095
Impact of monovalent cations on soil structure. Part II. Results of two Swiss soils
NASA Astrophysics Data System (ADS)
Farahani, Elham; Emami, Hojat; Keller, Thomas
2018-01-01
In this study, we investigated the impact of adding solutions with different potassium and sodium concentrations on dispersible clay, water retention characteristics, air permeability, and soil shrinkage behaviour using two agricultural soils from Switzerland with different clay content but similar organic carbon to clay ratio. Three different solutions (including only Na, only K, and the combination of both) were added to soil samples at three different cation ratio of soil structural stability levels, and the soil samples were incubated for one month. Our findings showed that the amount of readily dispersible clay increased with increasing Na concentrations and with increasing cation ratio of soil structural stability. The treatment with the maximum Na concentration resulted in the highest water retention and in the lowest shrinkage capacity. This was was associated with high amounts of readily dispersible clay. Air permeability generally increased during incubation due to moderate wetting and drying cycles, but the increase was negatively correlated with readily dispersible clay. Readily dispersible clay decreased with increasing K, while readily dispersible clay increased with increasing K in Iranian soil (Part I of our study). This can be attributed to the different clay mineralogy of the studied soils (muscovite in Part I and illite in Part II).
Method for noninvasive intracranial pressure measurement
Sinha, Dipen N.
2000-01-01
An ultrasonic-based method for continuous, noninvasive intracranial pressure (ICP) measurement and monitoring is described. The stress level in the skull bone is affected by pressure. This also changes the interfacial conditions between the dura matter and the skull bone. Standing waves may be set up in the skull bone and the layers in contact with the bone. At specific frequencies, there are resonance peaks in the response of the skull which can be readily detected by sweeping the excitation frequency on an excitation transducer in contact with a subject's head, while monitoring the standing wave characteristics from the signal received on a second, receiving transducer similarly in contact with the subject's head. At a chosen frequency, the phase difference between the excitation signal and the received signal can be determined. This difference can be related to the intracranial pressure and changes therein.
Colonoscopy Quality: Metrics and Implementation
Calderwood, Audrey H.; Jacobson, Brian C.
2013-01-01
Synopsis Colonoscopy is an excellent area for quality improvement 1 because it is high volume, has significant associated risk and expense, and there is evidence that variability in its performance affects outcomes. The best endpoint for validation of quality metrics in colonoscopy is colorectal cancer incidence and mortality, but because of feasibility issues, a more readily accessible metric is the adenoma detection rate (ADR). Fourteen quality metrics were proposed by the joint American Society of Gastrointestinal Endoscopy/American College of Gastroenterology Task Force on “Quality Indicators for Colonoscopy” in 2006, which are described in further detail below. Use of electronic health records and quality-oriented registries will facilitate quality measurement and reporting. Unlike traditional clinical research, implementation of quality improvement initiatives involves rapid assessments and changes on an iterative basis, and can be done at the individual, group, or facility level. PMID:23931862
Raman Spectroscopy of Ocular Tissue
NASA Astrophysics Data System (ADS)
Ermakov, Igor V.; Sharifzadeh, Mohsen; Gellermann, Warner
The optically transparent nature of the human eye has motivated numerous Raman studies aimed at the non-invasive optical probing of ocular tissue components critical to healthy vision. Investigations include the qualitative and quantitative detection of tissue-specific molecular constituents, compositional changes occurring with development of ocular pathology, and the detection and tracking of ocular drugs and nutritional supplements. Motivated by a better understanding of the molecular mechanisms leading to cataract formation in the aging human lens, a great deal of work has centered on the Raman detection of proteins and water content in the lens. Several protein groups and the hydroxyl response are readily detectable. Changes of protein compositions can be studied in excised noncataractous tissue versus aged tissue preparations as well as in tissue samples with artificially induced cataracts. Most of these studies are carried out in vitro using suitable animal models and conventional Raman techniques. Tissue water content plays an important role in optimum light transmission of the outermost transparent ocular structure, the cornea. Using confocal Raman spectroscopy techniques, it has been possible to non-invasively measure the water to protein ratio as a measure of hydration status and to track drug-induced changes of the hydration levels in the rabbit cornea at various depths. The aqueous humor, normally supplying nutrients to cornea and lens, has an advantageous anterior location for Raman studies. Increasing efforts are pursued to non-invasively detect the presence of glucose and therapeutic concentrations of antibiotic drugs in this medium. In retinal tissue, Raman spectroscopy proves to be an important tool for research into the causes of macular degeneration, the leading cause of irreversible vision disorders and blindness in the elderly. It has been possible to detect the spectral features of advanced glycation and advanced lipooxydation end products in excised tissue samples and synthetic preparations and thus to identify potential biomarkers for the onset of this disease. Using resonance Raman detection techniques, the concentration and spatial distribution of macular pigment, a protective compound, can be detected in the living human retina Useable in clinical settings for patient screening, the technology is suitable to investigate correlations between pigment concentration levels and risk for macular degeneration and to monitor increases in pigment levels occurring as a result of dietary intervention strategies.
Thornhill, Starla G; McLean, Robert J C
2018-01-01
In most bacteria, a global level of regulation, termed quorum sensing (QS), exists involving intercellular communication via the production and response to cell density-dependent signal molecules. QS has been associated with a number of important features in bacteria including virulence regulation and biofilm formation. Consequently, there is considerable interest in understanding, detecting, and inhibiting QS. N-acylated homoserine lactones (AHLs) are used as extracellular QS signals by a variety of Gram-negative bacteria. Chromobacterium violaceum, commonly found in soil and water, produces the characteristic purple pigment violacein, regulated by AHL-mediated QS. Based on this readily observed pigmentation phenotype, C. violaceum strains can be used to detect various aspects of AHL-mediated QS activity. In another commonly used bioassay organism, Agrobacterium tumefaciens, QS can be detected by the use of a reporter gene such as lacZ. Here, we describe several commonly used approaches incorporating C. violaceum and A. tumefaciens that can be used to detect AHL and QS inhibitors. Due to the inherent low susceptibility of biofilm bacteria to antimicrobial agents, biofilm dispersion, whereby bacteria reenter the planktonic community, is another increasingly important area of research. At least one signal, distinct from traditional QS, has been identified and there are a variety of other environmental factors that also trigger dispersion. We describe a microtiter-based experimental strategy whereby potential biofilm dispersion compounds can be screened.
Ground-Based Photomonitoring of Ecoregional Ecological Changes in Northwestern Yunnan, China
James P. Lassoie; Kiran E. Goldman; Robert K. Moseley
2006-01-01
Barring abrupt natural or anthropogenic disasters, ecological changes in terrestrial landscapes proceed at a pace not readily detected by humans. The use of historical repeat photography can provide valuable information about such changes, but, these studies are opportunistic in that they must rely on old photographs. Hence, their ecological interpretative power is...
A Note on Three Statistical Tests in the Logistic Regression DIF Procedure
ERIC Educational Resources Information Center
Paek, Insu
2012-01-01
Although logistic regression became one of the well-known methods in detecting differential item functioning (DIF), its three statistical tests, the Wald, likelihood ratio (LR), and score tests, which are readily available under the maximum likelihood, do not seem to be consistently distinguished in DIF literature. This paper provides a clarifying…
Exploring Ovulation & Pregnancy Using Over-the-Counter Products: A Novel Guided Inquiry
ERIC Educational Resources Information Center
Venditti, Jennifer J.; Surmacz, Cynthia A.
2012-01-01
In this guided inquiry, students explore the complex hormonal regulation of the female reproductive cycle using inexpensive ovulation and pregnancy detection kits that are readily available over the counter. This hands-on activity engages students in the practice of doing science as highlighted by the "National Science Education Standards." The…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allman, M. S., E-mail: shane.allman@boulder.nist.gov; Verma, V. B.; Stevens, M.
We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is employed to reduce the number of readout lines to 16. The cryogenic, optical, and electronic packaging to read out the array as well as characterization measurements are discussed.
A New Forensic Picture Polygraph Technique for Terrorist and Crime Deception System
ERIC Educational Resources Information Center
Costello, R. H. Brian; Axton, JoAnn; Gold, Karen L.
2006-01-01
The Forensic Terrorist Detection System called Pinocchio Assessment Profile (PAP) employs standard issue polygraphs for a non-verbal picture technique originated as a biofeedback careers interest instrument. The system can be integrated readily into airport screening protocols. However, the method does not rely on questioning or foreign language…
Highly enriched multiply-labeled stable isotopic compounds as atmospheric tracers
Goldblatt, M.; McInteer, B.B.
1974-01-29
Compounds multiply-labeled with stable isotopes and highly enriched in these isotopes are readily capable of detection in tracer experiments involving high dilutions. Thus, for example, /sup 13/C/sup 18/O/sub 2/ provides a useful tracer for following atmospheric pol lution produced as a result of fossil fuel burning. (Official Gazette)
Techniques For Measuring Absorption Coefficients In Crystalline Materials
NASA Astrophysics Data System (ADS)
Klein, Philipp H.
1981-10-01
Absorption coefficients smaller than 0.001 cm-1 can, with more or less difficulty, be measured by several techniques. With diligence, all methods can be refined to permit measurement of absorption coefficients as small as 0.00001 cm-1. Spectral data are most readily obtained by transmission (spectrophotometric) methods, using multiple internal reflection to increase effective sample length. Emissivity measurements, requiring extreme care in the elimination of detector noise and stray light, nevertheless afford the most accessible spectral data in the 0.0001 to 0.00001 cm-1 range. Single-wavelength informa-tion is most readily obtained with modifications of laser calorimetry. Thermo-couple detection of energy absorbed from a laser beam is convenient, but involves dc amplification techniques and is susceptible to stray-light problems. Photoacoustic detection, using ac methods, tends to diminish errors of these types, but at some expense in experimental complexity. Laser calorimetry has been used for measurements of absorption coefficients as small as 0.000003 cm-1. Both transmission and calorimetric data, taken as functions of intensity, have been used for measurement of nonlinear absorption coefficients.
Cheung, Melody; Lee, Wendy W Y; McCracken, John N; Larmour, Iain A; Brennan, Steven; Bell, Steven E J
2016-04-19
Raman analysis of dilute aqueous solutions is normally prevented by their low signal levels. A very general method to increase the concentration to detectable levels is to evaporate droplets of the sample to dryness, creating solid deposits which are then Raman probed. Here, superhydrophobic (SHP) wires with hydrophilic tips have been used as supports for drying droplets, which have the advantage that the residue is automatically deposited at the tip. The SHP wires were readily prepared in minutes using electroless galvanic deposition of Ag onto copper wires followed by modification with a polyfluorothiol (3,3,4,4,5,5,6,6,7,7,8,8,9,9,10,10,10-heptadecafluoro-1-decanethiol, HDFT). Cutting the coated wires with a scalpel revealed hydrophilic tips which could support droplets whose maximum size was determined by the wire diameter. Typically, 230 μm wires were used to support 0.6 μL droplets. Evaporation of dilute melamine droplets gave solid deposits which could be observed by scanning electron microscopy (SEM) and Raman spectroscopy. The limit of detection for melamine using a two stage evaporation procedure was 1 × 10(-6) mol dm(-3). The physical appearance of dried droplets of sucrose and glucose showed that the samples retained significant amounts of water, even under high vacuum. Nonetheless, the Raman detection limits of sucrose and glucose were 5 × 10(-4) and 2.5 × 10(-3) mol dm(-3), respectively, which is similar to the sensitivity reported for surface-enhanced Raman spectroscopy (SERS) detection of glucose. It was also possible to quantify the two sugars in mixtures at concentrations which were similar to those found in human blood through multivariate analysis.
Thakral, Naveen K; Mohapatra, Sarat; Stephenson, Gregory A; Suryanarayanan, Raj
2015-01-05
Tablets of amorphous indomethacin were compressed at 10, 25, 50, or 100 MPa using either an unlubricated or a lubricated die and stored individually at 35 °C in sealed Mylar pouches. At selected time points, tablets were analyzed by two-dimensional X-ray diffractometry (2D-XRD), which enabled us to profile the extent of drug crystallization in tablets, in both the radial and axial directions. To evaluate the role of lubricant, magnesium stearate was used as "internal" and/or "external" lubricant. Indomethacin crystallization propensity increased as a function of compression pressure, with 100 MPa pressure causing crystallization immediately after compression (detected using synchrotron radiation). However, the drug crystallization was not uniform throughout the tablets. In unlubricated systems, pronounced crystallization at the radial surface could be attributed to die wall friction. The tablet core remained substantially amorphous, irrespective of the compression pressure. Lubrication of the die wall with magnesium stearate, as external lubricant, dramatically decreased drug crystallization at the radial surface. The spatial heterogeneity in drug crystallization, as a function of formulation composition and compression pressure, was systematically investigated. When formulating amorphous systems as tablets, the potential for compression induced crystallization warrants careful consideration. Very low levels of crystallization on the tablet surface, while profoundly affecting product performance (decrease in dissolution rate), may not be readily detected by conventional analytical techniques. Early detection of crystallization could be pivotal in the successful design of a dosage form where, in order to obtain the desired bioavailability, the drug may be in a high energy state. Specialized X-ray diffractometric techniques (2D; use of high intensity synchrotron radiation) enabled detection of very low levels of drug crystallization and revealed the heterogeneity in crystallization within the tablet.
The patterns of melanoma presentation in Rijeka region.
Pavlović-Ružić, Ira; Jonjić, Nives; Zamolo, Gordana; Zuvić-Butorac, Marta; Katunarić, Miljenko; Pečanić, Sanja
2013-01-01
There is a global rising incidence of melanoma. For different reasons, the patterns of the incidence, appearance, gender, anatomical distribution and outcome vary among different geographic areas. Screening programs have led to better early detection of melanoma in Australia and some world areas. National Cancer Registry and practice data show the incidence in Croatia to be constantly rising. Despite public education programs about early detection, at clinical departments there are still many new advanced stage melanoma patients. We analyzed data on 157 patients treated and followed up for 10 years for T1b-T4aN0 skin melanoma. There was a difference in anatomical distribution of melanoma lesions in correlation with patient age (ANOVA test, F=3.51, p=0.009). A higher prevalence of shoulder melanoma was found in young people and of head/neck melanoma in the elderly (post-hoc Sheffe test, p=0.038). T4 lesions were more commonly found in men and T1 mainly in women (Pearson χ(2)-test, χ(2)=12.08, p=0.016). There was no difference in Clark level, but a significantly higher Breslow stage was found in men (t=-2.52, p=0.013). Men were much more prone to have head and neck, body and shoulder melanoma, whereas women had more melanoma on their legs and arms. Clark and Breslow levels were strongly correlated in leg melanoma; head localization showed no correlation at all. In conclusion, more attention should be devoted to improve the results in melanoma detection in men, especially considering the prevalence of body (back) and head/neck localizations, sometimes not readily accessible for visual detection. The pattern of distribution also pointed to the need for more attention to pay to shoulder melanoma in younger people.
Lebedeva, Irina V.; Pande, Praveen; Patton, Wayne F.
2011-01-01
An underlying mechanism for multi drug resistance (MDR) is up-regulation of the transmembrane ATP-binding cassette (ABC) transporter proteins. ABC transporters also determine the general fate and effect of pharmaceutical agents in the body. The three major types of ABC transporters are MDR1 (P-gp, P-glycoprotein, ABCB1), MRP1/2 (ABCC1/2) and BCRP/MXR (ABCG2) proteins. Flow cytometry (FCM) allows determination of the functional expression levels of ABC transporters in live cells, but most dyes used as indicators (rhodamine 123, DiOC2(3), calcein-AM) have limited applicability as they do not detect all three major types of ABC transporters. Dyes with broad coverage (such as doxorubicin, daunorubicin and mitoxantrone) lack sensitivity due to overall dimness and thus may yield a significant percentage of false negative results. We describe two novel fluorescent probes that are substrates for all three common types of ABC transporters and can serve as indicators of MDR in flow cytometry assays using live cells. The probes exhibit fast internalization, favorable uptake/efflux kinetics and high sensitivity of MDR detection, as established by multidrug resistance activity factor (MAF) values and Kolmogorov-Smirnov statistical analysis. Used in combination with general or specific inhibitors of ABC transporters, both dyes readily identify functional efflux and are capable of detecting small levels of efflux as well as defining the type of multidrug resistance. The assay can be applied to the screening of putative modulators of ABC transporters, facilitating rapid, reproducible, specific and relatively simple functional detection of ABC transporter activity, and ready implementation on widely available instruments. PMID:21799851
Sakuma, Shinji; Yu, James Y H; Quang, Timothy; Hiwatari, Ken-Ichiro; Kumagai, Hironori; Kao, Stephanie; Holt, Alex; Erskind, Jalysa; McClure, Richard; Siuta, Michael; Kitamura, Tokio; Tobita, Etsuo; Koike, Seiji; Wilson, Kevin; Richards-Kortum, Rebecca; Liu, Eric; Washington, Kay; Omary, Reed; Gore, John C; Pham, Wellington
2015-03-01
Thomsen-Friedenreich (TF) antigen belongs to the mucin-type tumor-associated carbohydrate antigen. Notably, TF antigen is overexpressed in colorectal cancer (CRC) but is rarely expressed in normal colonic tissue. Increased TF antigen expression is associated with tumor invasion and metastasis. In this study, we sought to validate a novel nanobeacon for imaging TF-associated CRC in a preclinical animal model. We developed and characterized the nanobeacon for use with fluorescence colonoscopy. In vivo imaging was performed on an orthotopic rat model of CRC. Both white light and fluorescence colonoscopy methods were utilized to establish the ratio-imaging index for the probe. The nanobeacon exhibited specificity for TF-associated cancer. Fluorescence colonoscopy using the probe can detect lesions at the stage which is not readily confirmed by conventional visualization methods. Further, the probe can report the dynamic change of TF expression as tumor regresses during chemotherapy. Data from this study suggests that fluorescence colonoscopy can improve early CRC detection. Supplemented by the established ratio-imaging index, the probe can be used not only for early detection, but also for reporting tumor response during chemotherapy. Furthermore, since the data obtained through in vivo imaging confirmed that the probe was not absorbed by the colonic mucosa, no registered toxicity is associated with this nanobeacon. Taken together, these data demonstrate the potential of this novel probe for imaging TF antigen as a biomarker for the early detection and prediction of the progression of CRC at the molecular level. © 2014 UICC.
Defeating crypsis: detection and learning of camouflage strategies.
Troscianko, Jolyon; Lown, Alice E; Hughes, Anna E; Stevens, Martin
2013-01-01
Camouflage is perhaps the most widespread defence against predators in nature and an active area of interdisciplinary research. Recent work has aimed to understand what camouflage types exist (e.g. background matching, disruptive, and distractive patterns) and their effectiveness. However, work has almost exclusively focused on the efficacy of these strategies in preventing initial detection, despite the fact that predators often encounter the same prey phenotype repeatedly, affording them opportunities to learn to find those prey more effectively. The overall value of a camouflage strategy may, therefore, reflect both its ability to prevent detection by predators and resist predator learning. We conducted four experiments with humans searching for hidden targets of different camouflage types (disruptive, distractive, and background matching of various contrast levels) over a series of touch screen trials. As with previous work, disruptive coloration was the most successful method of concealment overall, especially with relatively high contrast patterns, whereas potentially distractive markings were either neutral or costly. However, high contrast patterns incurred faster decreases in detection times over trials compared to other stimuli. In addition, potentially distractive markings were sometimes learnt more slowly than background matching markings, despite being found more readily overall. Finally, learning effects were highly dependent upon the experimental paradigm, including the number of prey types seen and whether subjects encountered targets simultaneously or sequentially. Our results show that the survival advantage of camouflage strategies reflects both their ability to avoid initial detection (sensory mechanisms) and predator learning (perceptual mechanisms).
Rekić, Dinko; Röshammar, Daniel; Bergstrand, Martin; Tarning, Joel; Calcagno, Andrea; D'Avolio, Antonio; Ormaasen, Vidar; Vigan, Marie; Barrail-Tran, Aurélie; Ashton, Michael; Gisslén, Magnus; Äbelö, Angela
2013-04-01
Atazanavir increases plasma bilirubin levels in a concentration-dependent manner. Due to less costly and readily available assays, bilirubin has been proposed as a marker of atazanavir exposure. In this work, a previously developed nomogram for detection of suboptimal atazanavir exposure is validated against external patient populations. The bilirubin nomogram was validated against 311 matching bilirubin and atazanavir samples from 166 HIV-1-infected Norwegian, French, and Italian patients on a ritonavir-boosted regimen. In addition, the nomogram was evaluated in 56 Italian patients on an unboosted regimen. The predictive properties of the nomogram were validated against observed atazanavir plasma concentrations. The use of the nomogram to detect non-adherence was also investigated by simulation. The bilirubin nomogram predicted suboptimal exposure in the patient populations on a ritonavir-boosted regimen with a negative predictive value of 97% (95% CI 95-100). The bilirubin nomogram and monitoring of atazanavir concentrations had similar predictive properties for detecting non-adherence based on simulations. Although both methods performed adequately during a period of non-adherence, they had lower predictive power to detect past non-adherence episodes. Using the bilirubin nomogram for detection of suboptimal atazanavir exposure in patients on a ritonavir-boosted regimen is a rapid and cost-effective alternative to routine measurements of the actual atazanavir exposure in plasma. Its application may be useful in clinical settings if atazanavir concentrations are not available.
Myochrysine Solution Structure and Reactivity
Jones, William B.; Zhao, Zheng; Dorsey, John G.; Tepperman, Katherine
1994-01-01
We have determined the framework structure of Myochrysine (disodium gold(I)thiomalate) in the solid state and extremely concentrated aqueous solution, previously. It consists of an open chain polymer with linear gold coordination to two thiolates from the thiomalic acid moieties which bridge between pairs of gold atoms providing an Au-S-Au angle of 95°. The question remained: was this structure relevant to the dilute solutions of drugs administered and the still lower concentrations of gold found in the bodies of patients (typically 1 ppm Au in blood and urine or 5 μM in Au). We have provided an answer to that question using extended X-ray absorption spectroscopy (EXAFS) and capillary zone electrophoresis (CZE). EXAFS studies confirm that the polymeric structure with two sulfur atoms per gold atom persists from molar concentrations down to millimolar concentrations. CZE is able to separate and detect Myochrysine at millimolar levels. More importantly, at micromolar levels Myochrysine solutions exhibit identical CZE behavior to that measured at millimolar levels. Thus, aqueous solutions of the drug remain oligomeric at concentrations commensurate with those found in patient blood and urine. The reactivity of Myochrysine with cyanide, a species especially prevalent in smoking patients, was explored using CZE. Cyanide freely replaces thiomalic acid to form [Au(CN)2]- and thiomalic acid via a mixed ligand intermediate. The overall apparent equilibrium constant (Kapp) for the reaction is 6×10-4M-1. Further reaction of [Au(CN)2]- with a large excess of L, where L is cysteine, N-acetylcysteine, or glutathione, shows that these amino acids readily replace cyanide to form [AuL2]-. These species are thus potential metabolites and could possibly be active forms of gold in vivo. That all of these species are readily separated and quantified using CZE demonstrates that capillary electrophoresis is an accessible and powerful tool to add to those used for the study of gold-based antiarthritis drugs. PMID:18476256
Advancing Bag-of-Visual-Words Representations for Lesion Classification in Retinal Images
Pires, Ramon; Jelinek, Herbert F.; Wainer, Jacques; Valle, Eduardo; Rocha, Anderson
2014-01-01
Diabetic Retinopathy (DR) is a complication of diabetes that can lead to blindness if not readily discovered. Automated screening algorithms have the potential to improve identification of patients who need further medical attention. However, the identification of lesions must be accurate to be useful for clinical application. The bag-of-visual-words (BoVW) algorithm employs a maximum-margin classifier in a flexible framework that is able to detect the most common DR-related lesions such as microaneurysms, cotton-wool spots and hard exudates. BoVW allows to bypass the need for pre- and post-processing of the retinographic images, as well as the need of specific ad hoc techniques for identification of each type of lesion. An extensive evaluation of the BoVW model, using three large retinograph datasets (DR1, DR2 and Messidor) with different resolution and collected by different healthcare personnel, was performed. The results demonstrate that the BoVW classification approach can identify different lesions within an image without having to utilize different algorithms for each lesion reducing processing time and providing a more flexible diagnostic system. Our BoVW scheme is based on sparse low-level feature detection with a Speeded-Up Robust Features (SURF) local descriptor, and mid-level features based on semi-soft coding with max pooling. The best BoVW representation for retinal image classification was an area under the receiver operating characteristic curve (AUC-ROC) of 97.8% (exudates) and 93.5% (red lesions), applying a cross-dataset validation protocol. To assess the accuracy for detecting cases that require referral within one year, the sparse extraction technique associated with semi-soft coding and max pooling obtained an AUC of 94.22.0%, outperforming current methods. Those results indicate that, for retinal image classification tasks in clinical practice, BoVW is equal and, in some instances, surpasses results obtained using dense detection (widely believed to be the best choice in many vision problems) for the low-level descriptors. PMID:24886780
Stellar variability and its implications for photometric planet detection with Kepler
NASA Astrophysics Data System (ADS)
Batalha, N. M.; Jenkins, J.; Basri, G. S.; Borucki, W. J.; Koch, D. G.
2002-01-01
Kepler is one of three candidates for the next NASA Discovery Mission and will survey the extended solar neighborhood to detect and characterize hundreds of terrestrial (and larger) planets in or near the habitable zone. Its strength lies in its ability to detect large numbers of Earth-sized planets - planets which produced a 10-4 change in relative stellar brightness during a transit across the disk of a sun-like parent star. Such a detection requires high instrumental relative precision and is facilitated by observing stars which are photometrically quiet on hourly timescales. Probing stellar variability across the HR diagram, one finds that many of the photometrically quietest stars are the F and G dwarfs. The Hipparcos photometric database shows the lowest photometric variances among stars of this spectral class. Our own Sun is a prime example with RMS variations over a few rotational cycles of typically (3 - 4)×10-4 (computed from VIRGO/DIARAD data taken Jan-Mar 2001). And variability on the hourly time scales crucial for planet detection is significantly smaller: just (2 - 5)×10-5. This bodes well for planet detection programs such as Kepler and Eddington. With significant numbers of photometrically quiet solar-type stars, Earth-sized planets should be readily identified provided they are abundant in the solar neighborhood. In support of the Kepler science objectives, we have initiated a study of stellar variability and its implications for planet detection. Herein, we summarize existing observational and theoretrical work with the objective of determining the percentage of stars in the Kepler field of view expected to be photometrically stable at a level which allows for Earth-sized planet detection.
Welch, K D; Gardner, D R; Pfister, J A; Panter, K E; Zieglar, J; Hall, J O
2012-12-01
Isocupressic acid (ICA) is the abortifacient compound in ponderosa pine (Pinus ponderosa L.) needles, which can cause late-term abortions in cattle (Bos taurus). However, cattle rapidly metabolize ICA to agathic acid (AGA) and subsequent metabolites. When pine needles are dosed orally to cattle, no ICA is detected in their serum, whereas AGA is readily detected. Recent research has demonstrated that AGA is also an abortifacient compound in cattle. The observation has been made that when cattle are dosed with labdane acids for an extended time, the concentration of AGA in serum increases for 1 to 2 d but then decreases to baseline after 5 to 6 d even though they are still being dosed twice daily. Therefore, in this study we investigated whether cattle conditioned to pine needles metabolize ICA, and its metabolites, faster than naïve cattle. Agathic acid was readily detected in the serum of naïve cattle fed ponderosa pine needles, whereas very little AGA was detected in the serum of cattle conditioned to pine needles. We also compared the metabolism of ICA in vitro using rumen cultures from pine-needle-conditioned and naïve cattle. In the rumen cultures from conditioned cattle, AGA concentrations were dramatically less than rumen cultures from naïve cattle. Thus, an adaptation occurs to cattle conditioned to pine needles such that the metabolism AGA by the rumen microflora is altered.
Yohn, David S.; Haendiges, Victoria A.; Grace, James T.
1966-01-01
Yohn, David S. (Roswell Park Memorial Institute, Buffalo, N.Y.), Victoria A. Haendiges, and James T. Grace, Jr. Yaba tumor poxvirus synthesis in vitro. I. Cytopathological, histochemical, and immunofluorescent studies. J. Bacteriol. 91:1977–1985. 1966.—Yaba tumor poxvirus synthesis in BSC-1 cell culture was followed sequentially with light microscopy, immunofluorescent microscopy, and various histochemical stains. The first evidence of infection was detected at 24 hr when nucleoli became hypertrophic, reflecting enhanced ribonucleic acid (RNA) synthesis. At 36 hr, deoxyribonucleic acid synthesis was detected in the cytoplasm. This was immediately followed by or associated with antigen synthesis at paranuclear sites and enhanced RNA synthesis in the cytoplasm. Cytoplasmic inclusions were readily apparent at 4 days in initially infected cells. Contiguous spread of virus was judged to have occurred around the third day of infection. The time required to complete the synthetic cycle from time of infection to production of infectious progeny was estimated to be of the order of 60 hr. This cycle is 6 to 10 times longer than for vaccinia virus. By light microscopy, cytopathic effects (CPE) were detectable in 5 days in heavily infected cultures. With 100 units or less of infectious virus, CPE was not readily detected until the 10th to 14th day. At this time, focal areas of infection classified either as microtumors or microplaques were present. Secondary foci appeared during the 4th week of incubation. Images PMID:4287080
NASA Astrophysics Data System (ADS)
Chen, Po-Cheng; Li, Yu-Chi; Ma, Jia-Yin; Huang, Jia-Yu; Chen, Chien-Fu; Chang, Huan-Tsung
2016-04-01
Polystyrene sulfonate (PSS), a strong polyelectrolyte, was used to prepare red photoluminescent PSS-penicillamine (PA) copper (Cu) nanoclusters (NC) aggregates, which displayed high selectivity and sensitivity to the detection of hydrogen sulfide (H2S). The size of the PSS-PA-Cu NC aggregates could be readily controlled from 5.5 μm to 173 nm using different concentrations of PSS, which enabled better dispersity and higher sensitivity towards H2S. PSS-PA-Cu NC aggregates provided rapid H2S detection by using the strong Cu-S interaction to quench NC photoluminescence as a sensing mechanism. As a result, a detection limit of 650 nM, which is lower than the maximum level permitted in drinking water by the World Health Organization, was achieved for the analysis of H2S in spring-water samples. Moreover, highly dispersed PSS-PA-Cu NC aggregates could be incorporated into a plate-format paper-based analytical device which enables ultra-low sample volumes (5 μL) and feature shorter analysis times (30 min) compared to conventional solution-based methods. The advantages of low reagent consumption, rapid result readout, limited equipment, and long-term storage make this platform sensitive and simple enough to use without specialized training in resource constrained settings.
Pacheco, M; Jurado-Sánchez, B; Escarpa, A
2018-02-20
Food poisoning caused by bacteria is a major cause of disease and death worldwide. Herein we describe the use of Janus micromotors as mobile sensors for the detection of toxins released by enterobacteria as indicators of food contamination. The micromotors are prepared by a Pickering emulsion approach and rely on the simultaneous encapsulation of platinum nanoparticles for enhanced bubble-propulsion and receptor-functionalized quantum dots (QDs) for selective binding with the 3-deoxy-d-manno-oct-2-ulosonic acid target in the endotoxin molecule. Lipopolysaccharides (LPS) from Salmonella enterica were used as target endotoxins, which upon interaction with the QDs induce a rapid quenching of the native fluorescence of the micromotors in a concentration-dependent manner. The micromotor assay can readily detect concentrations as low as 0.07 ng mL -1 of endotoxin, which is far below the level considered toxic to humans (275 μg mL -1 ). Micromotors have been successfully applied for the detection of Salmonella toxin in food samples in 15 min compared with several hours required by the existing Gold Standard method. Such ultrafast and reliable approach holds considerable promise for food contamination screening while awaiting the results of bacterial cultures in a myriad of food safety and security defense applications.
Vitiello, Benedetto; Shader, Richard I; Parker, Corette B; Ritz, Louise; Harlan, William; Greenblatt, David J; Gadde, Kishore M; Krishnan, K Ranga R; Davidson, Jonathan R T
2005-06-01
A previously reported clinical trial of Hypericum perforatum (St John's wort) in depression did not demonstrate efficacy. We assessed treatment adherence by measuring plasma hyperforin and evaluated the possible impact of adherence on study results. Outpatients with major depression (N = 340) were randomized to an 8-week trial of H. perforatum (900-1500 mg/d), sertraline (50-100 mg/d) as active comparator, or placebo. Plasma was available from 292 patients (86% of randomized). Samples from the placebo and H. perforatum groups were assayed for hyperforin, and samples from the sertraline group for sertraline/N-desmethyl-sertraline. Of the 104 patients randomized to placebo, 18 (17%) had detectable plasma hyperforin. Of the 97 patients randomized to H. perforatum, 17 (17%) had no detectable plasma hyperforin. All the assayed sertraline patients (N = 91) had plasma sertraline/N-desmethyl-sertraline. The clinical trial conclusions remained unchanged when only patients with plasma assay consistent with random assignment were included in the analyses. One of every 6 patients assigned to placebo had plasma hyperforin, and 1 of every 6 patients assigned to H. perforatum had no detectable plasma hyperforin. The finding underscores the difficulty of enforcing treatment adherence in clinical trials of preparations that are readily available in the community.
Context-specific effects of musical expertise on audiovisual integration
Bishop, Laura; Goebl, Werner
2014-01-01
Ensemble musicians exchange auditory and visual signals that can facilitate interpersonal synchronization. Musical expertise improves how precisely auditory and visual signals are perceptually integrated and increases sensitivity to asynchrony between them. Whether expertise improves sensitivity to audiovisual asynchrony in all instrumental contexts or only in those using sound-producing gestures that are within an observer's own motor repertoire is unclear. This study tested the hypothesis that musicians are more sensitive to audiovisual asynchrony in performances featuring their own instrument than in performances featuring other instruments. Short clips were extracted from audio-video recordings of clarinet, piano, and violin performances and presented to highly-skilled clarinetists, pianists, and violinists. Clips either maintained the audiovisual synchrony present in the original recording or were modified so that the video led or lagged behind the audio. Participants indicated whether the audio and video channels in each clip were synchronized. The range of asynchronies most often endorsed as synchronized was assessed as a measure of participants' sensitivities to audiovisual asynchrony. A positive relationship was observed between musical training and sensitivity, with data pooled across stimuli. While participants across expertise groups detected asynchronies most readily in piano stimuli and least readily in violin stimuli, pianists showed significantly better performance for piano stimuli than for either clarinet or violin. These findings suggest that, to an extent, the effects of expertise on audiovisual integration can be instrument-specific; however, the nature of the sound-producing gestures that are observed has a substantial effect on how readily asynchrony is detected as well. PMID:25324819
False Negatives for Remote Life Detection on Ocean-Bearing Planets: Lessons from the Early Earth
NASA Astrophysics Data System (ADS)
Reinhard, Christopher T.; Olson, Stephanie L.; Schwieterman, Edward W.; Lyons, Timothy W.
2017-04-01
Ocean-atmosphere chemistry on Earth has undergone dramatic evolutionary changes throughout its long history, with potentially significant ramifications for the emergence and long-term stability of atmospheric biosignatures. Though a great deal of work has centered on refining our understanding of false positives for remote life detection, much less attention has been paid to the possibility of false negatives, that is, cryptic biospheres that are widespread and active on a planet's surface but are ultimately undetectable or difficult to detect in the composition of a planet's atmosphere. Here, we summarize recent developments from geochemical proxy records and Earth system models that provide insight into the long-term evolution of the most readily detectable potential biosignature gases on Earth - oxygen (O2), ozone (O3), and methane (CH4). We suggest that the canonical O2-CH4 disequilibrium biosignature would perhaps have been challenging to detect remotely during Earth's ˜4.5-billion-year history and that in general atmospheric O2/O3 levels have been a poor proxy for the presence of Earth's biosphere for all but the last ˜500 million years. We further suggest that detecting atmospheric CH4 would have been problematic for most of the last ˜2.5 billion years of Earth's history. More broadly, we stress that internal oceanic recycling of biosignature gases will often render surface biospheres on ocean-bearing silicate worlds cryptic, with the implication that the planets most conducive to the development and maintenance of a pervasive biosphere will often be challenging to characterize via conventional atmospheric biosignatures.
Impact damage detection in sandwich composite structures using Lamb waves and laser vibrometry
NASA Astrophysics Data System (ADS)
Lamboul, B.; Passilly, B.; Roche, J.-M.; Osmont, D.
2013-01-01
This experimental study explores the feasibility of impact damage detection in composite sandwich structures using Lamb wave excitation and signals acquired with a laser Doppler vibrometer. Energy maps are computed from the transient velocity wave fields and used to highlight defect areas in impacted coupons of foam core and honeycomb core sandwich materials. The technique performs well for the detection of barely visible damage in this type of material, and is shown to be robust in the presence of wave reverberation. Defect extent information is not always readily retrieved from the obtained defect signatures, which depend on the wave - defect interaction mechanisms.
Detecting determinism from point processes.
Andrzejak, Ralph G; Mormann, Florian; Kreuz, Thomas
2014-12-01
The detection of a nonrandom structure from experimental data can be crucial for the classification, understanding, and interpretation of the generating process. We here introduce a rank-based nonlinear predictability score to detect determinism from point process data. Thanks to its modular nature, this approach can be adapted to whatever signature in the data one considers indicative of deterministic structure. After validating our approach using point process signals from deterministic and stochastic model dynamics, we show an application to neuronal spike trains recorded in the brain of an epilepsy patient. While we illustrate our approach in the context of temporal point processes, it can be readily applied to spatial point processes as well.
On the detection of carbon monoxide as an anti-biosignature in exoplanetary atmospheres
NASA Astrophysics Data System (ADS)
Wang, Yuwei; Tian, Feng; Li, Tong; Hu, Yongyun
2016-03-01
Recent works suggest that oxygen can be maintained on lifeless exoplanets in the habitable zones of M dwarfs as the results of photochemical reactions. However, the same photochemical models also predict high concentrations of carbon monoxide (CO) in the corresponding atmospheres. Here we use a line-by-line radiative transfer model to investigate the observation requirements of O2 and CO in such atmospheres. The results show that photochemically produced CO can be readily detected at 1.58, 2.34, and 4.67 μm. We suggest that future missions aiming at characterization of exoplanetary atmospheres consider detections of CO as an anti-biosignature.
Arbitrary Multicolor Photodetection by Hetero-integrated Semiconductor Nanostructures
Sang, Liwen; Hu, Junqing; Zou, Rujia; Koide, Yasuo; Liao, Meiyong
2013-01-01
The typical photodetectors can only detect one specific optical spectral band, such as InGaAs and graphene-PbS quantum dots for near-infrared (NIR) light detection, CdS and Si for visible light detection, and ZnO and III-nitrides for UV light detection. So far, none of the developed photodetector can achieve the multicolor detection with arbitrary spectral selectivity, high sensitivity, high speed, high signal-to-noise ratio, high stability, and simplicity (called 6S requirements). Here, we propose a universal strategy to develop multicolor photodetectors with arbitrary spectral selectivity by integrating various semiconductor nanostructures on a wide-bandgap semiconductor or an insulator substrate. Because the photoresponse of each spectral band is determined by each semiconductor nanostructure or the semiconductor substrate, multicolor detection satisfying 6S requirements can be readily satisfied by selecting the right semiconductors. PMID:23917790
Liu, Jikun; White, Ian; DeVoe, Don L.
2011-01-01
The use of porous polymer monoliths functionalized with silver nanoparticles is introduced in this work for high-sensitivity surface-enhanced Raman scattering (SERS) detection. Preparation of the SERS detection elements is a simple process comprising the synthesis of a discrete polymer monolith section within a silica capillary, followed by physically trapping silver nanoparticle aggregates within the monolith matrix. A SERS detection limit of 220 fmol for Rhodamine 6G (R6G) is demonstrated, with excellent signal stability over a 24 h period. The capability of the SERS-active monolith for label-free detection of biomolecules was demonstrated by measurements of bradykinin and cyctochrome c. The SERS-active monoliths can be readily integrated into miniaturized micro-total-analysis systems for on-line and label-free detection for a variety of biosensing, bioanalytical, and biomedical applications. PMID:21322579
Comte, Alexia; Gräfenhan, Tom; Links, Matthew G; Hemmingsen, Sean M; Dumonceaux, Tim J
2017-01-01
We examined the epiphytic microbiome of cereal grain using the universal barcode chaperonin-60 (cpn60). Microbial community profiling of seed washes containing DNA extracts prepared from field-grown cereal grain detected sequences from a fungus identified only to Class Sordariomycetes. To identify the fungal sequence and to improve the reference database, we determined cpn60 sequences from field-collected and reference strains of the ergot fungus, Claviceps purpurea. These data allowed us to identify this fungal sequence as deriving from C. purpurea, and suggested that C. purpurea DNA is readily detectable on agricultural commodities, including those for which ergot was not identified as a grading factor. To get a sense of the prevalence and level of C. purpurea DNA in cereal grains, we developed a quantitative PCR assay based on the fungal internal transcribed spacer (ITS) and applied it to 137 samples from the 2014 crop year. The amount of Claviceps DNA quantified correlated strongly with the proportion of ergot sclerotia identified in each grain lot, although there was evidence that non-target organisms were responsible for some false positives with the ITS-based assay. We therefore developed a cpn60-targeted loop-mediated isothermal amplification assay and applied it to the same grain wash samples. The time to positive displayed a significant, inverse correlation to ergot levels determined by visual ratings. These results indicate that both laboratory-based and field-adaptable molecular diagnostic assays can be used to detect and quantify pathogen load in bulk commodities using cereal grain washes.
Comte, Alexia; Gräfenhan, Tom; Links, Matthew G.; Hemmingsen, Sean M.
2017-01-01
We examined the epiphytic microbiome of cereal grain using the universal barcode chaperonin-60 (cpn60). Microbial community profiling of seed washes containing DNA extracts prepared from field-grown cereal grain detected sequences from a fungus identified only to Class Sordariomycetes. To identify the fungal sequence and to improve the reference database, we determined cpn60 sequences from field-collected and reference strains of the ergot fungus, Claviceps purpurea. These data allowed us to identify this fungal sequence as deriving from C. purpurea, and suggested that C. purpurea DNA is readily detectable on agricultural commodities, including those for which ergot was not identified as a grading factor. To get a sense of the prevalence and level of C. purpurea DNA in cereal grains, we developed a quantitative PCR assay based on the fungal internal transcribed spacer (ITS) and applied it to 137 samples from the 2014 crop year. The amount of Claviceps DNA quantified correlated strongly with the proportion of ergot sclerotia identified in each grain lot, although there was evidence that non-target organisms were responsible for some false positives with the ITS-based assay. We therefore developed a cpn60-targeted loop-mediated isothermal amplification assay and applied it to the same grain wash samples. The time to positive displayed a significant, inverse correlation to ergot levels determined by visual ratings. These results indicate that both laboratory-based and field-adaptable molecular diagnostic assays can be used to detect and quantify pathogen load in bulk commodities using cereal grain washes. PMID:28257512
A note on stray light in the Tübingen perimeter.
Weale, R A; Wheeler, C
1977-01-01
Measurements were made of the relative intensity of light scattered in the neighbourhood of the large and small targets on the Tübingen perimeter. Two target intensities were studied. The scattered light fraction ranged from 0-1 to 25% and its effect was detected more readily by young than by older observers. PMID:843510
Bi, Sai; Yue, Shuzhen; Wu, Qiang; Ye, Jiayan
2016-04-07
Toehold-mediated strand displacement-based nanocircuits are developed by integrating catalytic hairpin assembly (CHA) with hybridization chain reaction (HCR), which achieves self-assembly of hyperbranched DNA structures and is readily utilized as an enzyme-free amplifier for homogeneous CRET detection of microRNA with high sensitivity and selectivity.
Accent Detection and Social Cognition: Evidence of Protracted Learning
ERIC Educational Resources Information Center
Creel, Sarah C.
2018-01-01
How and when do children become aware that speakers have different accents? While adults readily make a variety of subtle social inferences based on speakers' accents, findings from children are more mixed: while one line of research suggests that even infants may be acutely sensitive to accent unfamiliarity, other studies suggest that 5-year-olds…
Students Doing Chemistry: A Hand-On Experience for K-12
ERIC Educational Resources Information Center
Selco, Jodye I.; Bruno, Mary; Chan, Sue
2012-01-01
A hands-on, minds-on inquiry chemistry experiment was developed for use in K-12 schools that enables students to combine the chemicals of their choice and observe the results. The chemistry involved is water based and builds upon acid-base, double displacement, and iodometric detection of starch reactions. Chemicals readily available in the…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-18
... Survey As part of the feasibility study for Shell's Alaskan prospects a survey is required to identify...): (1) Tolerance Numerous studies have shown that pulsed sounds from airguns are often readily detectable in the water at distances of many kilometers. Numerous studies have also shown that marine mammals...
USDA-ARS?s Scientific Manuscript database
Although standard methods for analyzing water samples for the protozoan parasites Cryptosporidium spp. and Giardia duodenalis are available and widely used, equivalent methods for analyzing water samples for Toxoplasma oocysts are lacking. This is partly due to the lack of a readily available, relia...
A New Statistic for Detection of Aberrant Answer Changes
ERIC Educational Resources Information Center
Sinharay, Sandip; Duong, Minh Q.; Wood, Scott W.
2017-01-01
As noted by Fremer and Olson, analysis of answer changes is often used to investigate testing irregularities because the analysis is readily performed and has proven its value in practice. Researchers such as Belov, Sinharay and Johnson, van der Linden and Jeon, van der Linden and Lewis, and Wollack, Cohen, and Eckerly have suggested several…
ERIC Educational Resources Information Center
Bertin, Evelin; Bhatt, Ramesh S.
2001-01-01
Examined three possible explanations for findings that infants detect textural discrepancies based on individual features more readily than on feature conjunctions. Found that none of the proposed factors could explain 5.5-month-olds' superior processing of featural over conjunction-based textural discrepancies. Findings suggest that in infancy,…
Advanced NDE research in electromagnetic, thermal, and coherent optics
NASA Technical Reports Server (NTRS)
Skinner, S. Ballou
1992-01-01
A new inspection technology called magneto-optic/eddy current imaging was investigated. The magneto-optic imager makes readily visible irregularities and inconsistencies in airframe components. Other research observed in electromagnetics included (1) disbond detection via resonant modal analysis; (2) AC magnetic field frequency dependence of magnetoacoustic emission; and (3) multi-view magneto-optic imaging. Research observed in the thermal group included (1) thermographic detection and characterization of corrosion in aircraft aluminum; (2) a multipurpose infrared imaging system for thermoelastic stress detection; (3) thermal diffusivity imaging of stress induced damage in composites; and (4) detection and measurement of ice formation on the space shuttle main fuel tank. Research observed in the optics group included advancements in optical nondestructive evaluation (NDE).
Minimum Detectable Dose as a Measure of Bioassay Programme Capability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.
2003-01-01
This paper suggests that minimum detectable dose (MDD) be used to describe the capability of bioassay programs for which intakes are expected to be rare. This allows expression of the capability in units that correspond directly to primary dose limits. The concept uses the well-established analytical statistic minimum detectable amount (MDA) as the starting point and assumes MDA detection at a prescribed time post intake. The resulting dose can then be used as an indication of the adequacy or capability of the program for demonstrating compliance with the performance criteria. MDDs can be readily tabulated or plotted to demonstrate themore » effectiveness of different types of monitoring programs. The inclusion of cost factors for bioassay measurements can allow optimisation.« less
Minimum detectable dose as a measure of bioassay programme capability.
Carbaugh, E H
2003-01-01
This paper suggests that minimum detectable dose (MDD) be used to describe the capability of bioassay programmes for which intakes are expected to be rare. This allows expression of the capability in units that correspond directly to primary dose limits. The concept uses the well established analytical statistic minimum detectable amount (MDA) as the starting point, and assumes MDA detection at a prescribed time post-intake. The resulting dose can then be used as an indication of the adequacy or capability of the programme for demonstrating compliance with the performance criteria. MDDs can be readily tabulated or plotted to demonstrate the effectiveness of different types of monitoring programmes. The inclusion of cost factors for bioassay measurements can allow optimisation.
Eberhart, Charles G; Chaudhry, Aneeka; Daniel, Richard W; Khaki, Leila; Shah, Keerti V; Gravitt, Patti E
2005-01-01
Background p53 mutations are relatively uncommon in medulloblastoma, but abnormalities in this cell cycle pathway have been associated with anaplasia and worse clinical outcomes. We correlated p53 protein expression with pathological subtype and clinical outcome in 75 embryonal brain tumors. The presence of JC virus, which results in p53 protein accumulation, was also examined. Methods p53 protein levels were evaluated semi-quantitatively in 64 medulloblastomas, 3 atypical teratoid rhabdoid tumors (ATRT), and 8 supratentorial primitive neuroectodermal tumors (sPNET) using immunohistochemistry. JC viral sequences were analyzed in DNA extracted from 33 frozen medulloblastoma and PNET samples using quantitative polymerase chain reaction. Results p53 expression was detected in 18% of non-anaplastic medulloblastomas, 45% of anaplastic medulloblastomas, 67% of ATRT, and 88% of sPNET. The increased p53 immunoreactivity in anaplastic medulloblastoma, ATRT, and sPNET was statistically significant. Log rank analysis of clinical outcome revealed significantly shorter survival in patients with p53 immunopositive embryonal tumors. No JC virus was identified in the embryonal brain tumor samples, while an endogenous human retrovirus (ERV-3) was readily detected. Conclusion Immunoreactivity for p53 protein is more common in anaplastic medulloblastomas, ATRT and sPNET than in non-anaplastic tumors, and is associated with worse clinical outcomes. However, JC virus infection is not responsible for increased levels of p53 protein. PMID:15717928
Novel infrared detector based on a tunneling displacement transducer
NASA Technical Reports Server (NTRS)
Kenny, T. W.; Kaiser, W. J.; Waltman, S. B.; Reynolds, J. K.
1991-01-01
The paper describes the design, fabrication, and characteristics of a novel infrared detector based on the principle of Golay's (1947) pneumatic infrared detector, which uses the expansion of a gas to detect infrared radiation. The present detector is constructed entirely from micromachined silicon and uses an electron tunneling displacement transducer for the detection of gas expansion. The sensitivity of the new detector is competitive with the best commercial pyroelectric sensors and can be readily improved by an order of magnitude through the use of an optimized transducer.
Digital image profilers for detecting faint sources which have bright companions
NASA Technical Reports Server (NTRS)
Morris, Elena; Flint, Graham; Slavey, Robert
1992-01-01
For this program, an image profiling system was developed which offers the potential for detecting extremely faint optical sources that are located in close proximity to bright companions. The approach employed is novel in three respects. First, it does not require an optical system wherein extraordinary measures must be taken to minimize diffraction and scatter. Second, it does not require detectors possessing either extreme uniformity in sensitivity or extreme temporal stability. Finally, the system can readily be calibrated, or nulled, in space by testing against an unresolved singular stellar source.
Seed viability detection using computerized false-color radiographic image enhancement
NASA Technical Reports Server (NTRS)
Vozzo, J. A.; Marko, Michael
1994-01-01
Seed radiographs are divided into density zones which are related to seed germination. The seeds which germinate have densities relating to false-color red. In turn, a seed sorter may be designed which rejects those seeds not having sufficient red to activate a gate along a moving belt containing the seed source. This results in separating only seeds with the preselected densities representing biological viability lending to germination. These selected seeds demand a higher market value. Actual false-coloring isn't required for a computer to distinguish the significant gray-zone range. This range can be predetermined and screened without the necessity of red imaging. Applying false-color enhancement is a means of emphasizing differences in densities of gray within any subject from photographic, radiographic, or video imaging. Within the 0-255 range of gray levels, colors can be assigned to any single level or group of gray levels. Densitometric values then become easily recognized colors which relate to the image density. Choosing a color to identify any given density allows separation by morphology or composition (form or function). Additionally, relative areas of each color are readily available for determining distribution of that density by comparison with other densities within the image.
Phage & phosphatase: a novel phage-based probe for rapid, multi-platform detection of bacteria.
Alcaine, S D; Pacitto, D; Sela, D A; Nugen, S R
2015-11-21
Genetic engineering of bacteriophages allows for the development of rapid, highly specific, and easily manufactured probes for the detection of bacterial pathogens. A challenge for novel probes is the ease of their adoption in real world laboratories. We have engineered the bacteriophage T7, which targets Escherichia coli, to carry the alkaline phosphatase gene, phoA. This inclusion results in phoA overexpression following phage infection of E. coli. Alkaline phosphatase is commonly used in a wide range of diagnostics, and thus a signal produced by our phage-based probe could be detected using common laboratory equipment. Our work demonstrates the successful: (i) modification of T7 phage to carry phoA; (ii) overexpression of alkaline phosphatase in E. coli; and (iii) detection of this T7-induced alkaline phosphatase activity using commercially available colorimetric and chemilumiscent methods. Furthermore, we demonstrate the application of our phage-based probe to rapidly detect low levels of bacteria and discern the antibiotic resistance of E. coli isolates. Using our bioengineered phage-based probe we were able to detect 10(3) CFU per mL of E. coli in 6 hours using a chemiluminescent substrate and 10(4) CFU per mL within 7.5 hours using a colorimetric substrate. We also show the application of this phage-based probe for antibiotic resistance testing. We were able to determine whether an E. coli isolate was resistant to ampicillin within 4.5 hours using chemiluminescent substrate and within 6 hours using a colorimetric substrate. This phage-based scheme could be readily adopted in labs without significant capital investments and can be translated to other phage-bacteria pairs for further detection.
Costanza, Jed; Pennell, Kurt D
2008-02-01
The rates of hydrolysis reported for tetrachloroethylene (PCE) and trichloroethylene (TCE) at elevated temperatures range over two orders-of-magnitude, where some of the variability may be due to the presence of a gas phase. Recent studies suggest that volatile organic analysis (VOA) vials provide a low-cost and readily available zero headspace system for measuring aqueous-phase hydrolysis rates. This work involved measuring rates of PCE and TCE disappearance and the corresponding appearance of dechlorination products in water-filled VOA vials and flame-sealed ampules incubated at 21 and 55 degrees C for up to 95.5 days. While PCE and TCE concentrations readily decreased in the VOA vials to yield first-order half lives of 11.2 days for PCE and 21.1 days for TCE at 55 degrees C, concentrations of anticipated dechlorination products, including chloride, remained constant or were not detected. The rate of PCE disappearance was 34 times faster in VOA vials at 55 degrees C compared to values obtained with flame-sealed ampules containing PCE-contaminated water. In addition, the concentration of TCE increased slightly in flame-sealed ampules incubated at 55 degrees C, while a decrease in TCE levels was observed in the VOA vials. The observed losses of PCE and TCE in the VOA vials were attributed to diffusion and sorption in the septa, rather than to dechlorination. These findings demonstrate that VOA vials are not suitable for measuring rates of volatile organic compound hydrolysis at elevated temperatures.
A Spike Cocktail Approach to Improve Microbial Performance Monitoring for Water Reuse.
Zimmerman, Brian D; Korajkic, Asja; Brinkman, Nichole E; Grimm, Ann C; Ashbolt, Nicholas J; Garland, Jay L
Water reuse, via either centralized treatment of traditional wastewater or decentralized treatment and on-site reuse, is becoming an increasingly important element of sustainable water management. Despite advances in waterborne pathogen detection methods, low and highly variable pathogen levels limit their utility for routine evaluation of health risks in water reuse systems. Therefore, there is a need to improve our understanding of the linkage between pathogens and more readily measured process indicators during treatment. This paper describes an approach for constructing spiking experiments to relate the behavior of viral, bacterial, and protozoan pathogens with relevant process indicators. General issues are reviewed, and the spiking protocol is applied as a case study example to improve microbial performance monitoring and health risk evaluation in a water reuse system. This approach provides a foundation for the development of novel approaches to improve real or near-real time performance monitoring of water recycling systems.
Extension of Gutenberg-Richter distribution to MW -1.3, no lower limit in sight
NASA Astrophysics Data System (ADS)
Boettcher, Margaret S.; McGarr, A.; Johnston, Malcolm
2009-05-01
With twelve years of seismic data from TauTona Gold Mine, South Africa, we show that mining-induced earthquakes follow the Gutenberg-Richter relation with no scale break down to the completeness level of the catalog, at moment magnitude M W -1.3. Events recorded during relatively quiet hours in 2006 indicate that catalog detection limitations, not earthquake source physics, controlled the previously reported minimum magnitude in this mine. Within the Natural Earthquake Laboratory in South African Mines (NELSAM) experiment's dense seismic array, earthquakes that exhibit shear failure at magnitudes as small as M W -3.9 are observed, but we find no evidence that M W -3.9 represents the minimum magnitude. In contrast to previous work, our results imply small nucleation zones and that earthquake processes in the mine can readily be scaled to those in either laboratory experiments or natural faults.
Evidence for Coincident Fusion Products Using Silicon Surface-barrier Detectors
NASA Astrophysics Data System (ADS)
Jones, Steven; Scott, Mark; Keeney, Frank
2002-10-01
We report experimental results showing coincident proton and triton production from the reaction: d + d --> t (1.01 MeV) + p (3.02 MeV). Partially-deuterided thin titanium foils were positioned between two silicon surface-barrier detectors which were mounted in a small cylindrical vacuum chamber which also served as a Faraday cage. We performed Monte Carlo studies using the SRIM code to determine the expected energies of arriving particles after they exit the host foil. The dual-coincidence requirement reduces background to very low levels so that low yields from very thin TiD foils can be readily detected. In one sequence of experiments, we observed 74 foreground coincidences in the regions of interest compared with 24 background counts; the statistical significance is approximately ten standard deviations. A striking advance is that the repeatability from the dual-coincidence experiments is currently greater than 70%.
Extension of Gutenberg-Richter distribution to Mw -1.3, no lower limit in sight
Boettcher, M.S.; McGarr, A.; Johnston, M.
2009-01-01
[1] With twelve years of seismic data from TauTona Gold Mine, South Africa, we show that mining-induced earthquakes follow the Gutenberg-Richter relation with no scale break down to the completeness level of the catalog, at moment magnitude Mw -1.3. Events recorded during relatively quiet hours in 2006 indicate that catalog detection limitations, not earthquake source physics, controlled the previously reported minimum magnitude in this mine. Within the Natural Earthquake Laboratory in South African Mines (NELSAM) experiment's dense seismic array, earthquakes that exhibit shear failure at magnitudes as small as Mw -3.9 are observed, but we find no evidence that Mw -3.9 represents the minimum magnitude. In contrast to previous work, our results imply small nucleation zones and that earthquake processes in the mine can readily be scaled to those in either laboratory experiments or natural faults.
Cell signaling, post-translational protein modifications and NMR spectroscopy
Theillet, Francois-Xavier; Smet-Nocca, Caroline; Liokatis, Stamatios; Thongwichian, Rossukon; Kosten, Jonas; Yoon, Mi-Kyung; Kriwacki, Richard W.; Landrieu, Isabelle; Lippens, Guy
2016-01-01
Post-translationally modified proteins make up the majority of the proteome and establish, to a large part, the impressive level of functional diversity in higher, multi-cellular organisms. Most eukaryotic post-translational protein modifications (PTMs) denote reversible, covalent additions of small chemical entities such as phosphate-, acyl-, alkyl- and glycosyl-groups onto selected subsets of modifiable amino acids. In turn, these modifications induce highly specific changes in the chemical environments of individual protein residues, which are readily detected by high-resolution NMR spectroscopy. In the following, we provide a concise compendium of NMR characteristics of the main types of eukaryotic PTMs: serine, threonine, tyrosine and histidine phosphorylation, lysine acetylation, lysine and arginine methylation, and serine, threonine O-glycosylation. We further delineate the previously uncharacterized NMR properties of lysine propionylation, butyrylation, succinylation, malonylation and crotonylation, which, altogether, define an initial reference frame for comprehensive PTM studies by high-resolution NMR spectroscopy. PMID:23011410
Highly Enhanced Raman Scattering on Carbonized Polymer Films.
Yoon, Jong-Chul; Hwang, Jongha; Thiyagarajan, Pradheep; Ruoff, Rodney S; Jang, Ji-Hyun
2017-06-28
We have discovered a carbonized polymer film to be a reliable and durable carbon-based substrate for carbon enhanced Raman scattering (CERS). Commercially available SU8 was spin coated and carbonized (c-SU8) to yield a film optimized to have a favorable Fermi level position for efficient charge transfer, which results in a significant Raman scattering enhancement under mild measurement conditions. A highly sensitive CERS (detection limit of 10 -8 M) that was uniform over a large area was achieved on a patterned c-SU8 film and the Raman signal intensity has remained constant for 2 years. This approach works not only for the CMOS-compatible c-SU8 film but for any carbonized film with the correct composition and Fermi level, as demonstrated with carbonized-PVA (poly(vinyl alcohol)) and carbonized-PVP (polyvinylpyrollidone) films. Our study certainly expands the rather narrow range of Raman-active material platforms to include robust carbon-based films readily obtained from polymer precursors. As it uses broadly applicable and cheap polymers, it could offer great advantages in the development of practical devices for chemical/bio analysis and sensors.
A colorimetric sensor array of porous pigments.
Lim, Sung H; Kemling, Jonathan W; Feng, Liang; Suslick, Kenneth S
2009-12-01
The development of a low-cost, simple colorimetric sensor array capable of the detection and identification of toxic gases is reported. This technology uses a disposable printed array of porous pigments in which metalloporphyrins and chemically-responsive dyes are immobilized in a porous matrix of organically modified siloxanes (ormosils) and printed on a porous membrane. The printing of the ormosil into the membrane is highly uniform and does not lessen the porosity of the membrane, as shown by scanning electron microscopy. When exposed to an analyte, these pigments undergo reactions that result in well-defined color changes due to strong chemical interactions: ligation to metal ions, Lewis or Brønsted acid-base interactions, hydrogen bonding, etc. Striking visual identification of 3 toxic gases has been shown at the IDLH (immediately dangerous to life and health) concentration, at the PEL (permissible exposure level), and at a level well below the PEL. Identification and quantification of analytes were achieved using the color change profiles, which were readily distinguishable in a hierarchical clustering analysis (HCA) dendrogram, with no misclassifications in 50 trials.
A colorimetric sensor array of porous pigments
Lim, Sung H.; Kemling, Jonathan W.; Feng, Liang
2010-01-01
The development of a low-cost, simple colorimetric sensor array capable of detection and identification of toxic gases is reported. This technology uses a disposable printed array of porous pigments in which metalloporphyrins and chemically responsive dyes are immobilized in a porous matrix of organically modified siloxanes (ormosils) and printed on a porous membrane. The printing of the ormosil into the membrane is highly uniform and does not lessen the porosity of the membrane, as shown by scanning electron microscopy. When exposed to an analyte, these pigments undergo reactions that result in well-defined color changes due to strong chemical interactions: ligation to metal ions, Lewis or Bronsted acid-base interactions, hydrogen bonding, etc. Striking visual identification of 3 toxic gases has been shown at the IDLH (immediately dangerous to life and health), at the PEL (permissible exposure level), and at a level well below the PEL. Identification and quantification of analytes were achieved using the color change profiles, which were readily distinguishable in a hierarchical clustering analysis (HCA) dendrogram, with no misclassifications in 50 trials. PMID:19918616
Street, R A; Kulkarni, M G; Stirk, W A; Southway, C; Van Staden, J
2008-08-01
South African medicinal plants are traditionally harvested from a wide range of undisclosed locations by plant gatherers. Thus, there is a risk that plant material may be exposed to a variety of pollutants. The variation in five heavy metals (arsenic, cadmium, cobalt, nickel, and lead) and six essential elements (boron, copper, iron, manganese, molybdenum, and zinc) was determined in commonly used South African medicinal plants obtained from street markets. Elemental content was determined using inductively coupled plasma optical emission spectrophotometry. The reliability of the procedure was ensured by analysing a certified reference material. Medicinal plant samples contained arsenic and cadmium at levels exceeding the World Health Organization limits of 1 and 0.3 mg kg(-1) respectively. Lead and nickel were detected in all samples. Elevated iron and manganese levels were recorded in certain plant species. Multiple metal contamination of parts of medicinal plants gives grounds for concern. This study emphasizes the unsafe consequences of the South African practice of collecting medicinal plants from undisclosed locations and making these readily available to the public.
GHOST: global hepatitis outbreak and surveillance technology.
Longmire, Atkinson G; Sims, Seth; Rytsareva, Inna; Campo, David S; Skums, Pavel; Dimitrova, Zoya; Ramachandran, Sumathi; Medrzycki, Magdalena; Thai, Hong; Ganova-Raeva, Lilia; Lin, Yulin; Punkova, Lili T; Sue, Amanda; Mirabito, Massimo; Wang, Silver; Tracy, Robin; Bolet, Victor; Sukalac, Thom; Lynberg, Chris; Khudyakov, Yury
2017-12-06
Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics expertise. Improvement in molecular detection capacity will contribute to increasing the rate of transmission detection, thus providing opportunity for rapid, accurate and effective response to outbreaks of hepatitis C. Although GHOST was originally developed for hepatitis C surveillance, its modular structure is readily applicable to other infectious diseases. Worldwide availability of GHOST for the detection of HCV transmissions will foster deeper involvement of public health researchers and practitioners in hepatitis C outbreak investigation.
Central regulation of energy homeostasis intelligent design: how to build the perfect survivor.
Levin, Barry E
2006-08-01
The perfect survivor must be able to eat and store as many calories as possible when food is readily available as a buffer against periods of scarcity. He must also reduce energy expenditure when food is scarce and efficiently and accurately restore lost adipose stores when food is again available. These processes are dependent on information relayed to a distributed central network of metabolic sensing neurons through hard-wired neural, metabolic, and hormonal signals from the periphery. These sensing neurons engage neuroendocrine, autonomic, and motor processes involved in arousal, motor activity, and the ingestion, absorption, assimilation, storage, and expenditure of calories. A raised threshold in these metabolic sensors for detecting inhibitory signals from increasing adipose stores allows continued intake of excess calories when they are readily available. Unfortunately, this mechanism for surviving periods of feast and famine predisposes the perfect survivor to become obese when highly palatable, energy dense foods are readily available at low energetic cost. It further assures that raised adipose stores are metabolically defended against attempts to lower them. Thus, effective treatment of obesity will only come with a better understanding of the physiological, metabolic, and neurochemical processes that ensure this defense of an elevated body weight.
ERIC Educational Resources Information Center
Lane, W. Brian
2014-01-01
The traditional introductory-level meterstick-balancing lab assumes that students already know what torque is and that they readily identify it as a physical quantity of interest. We propose a modified version of this activity in which students qualitatively and quantitatively measure the amount of force required to keep the meterstick level. The…
Gold Nanoparticles-Based Barcode Analysis for Detection of Norepinephrine.
An, Jeung Hee; Lee, Kwon-Jai; Choi, Jeong-Woo
2016-02-01
Nanotechnology-based bio-barcode amplification analysis offers an innovative approach for detecting neurotransmitters. We evaluated the efficacy of this method for detecting norepinephrine in normal and oxidative-stress damaged dopaminergic cells. Our approach use a combination of DNA barcodes and bead-based immunoassays for detecting neurotransmitters with surface-enhanced Raman spectroscopy (SERS), and provides polymerase chain reaction (PCR)-like sensitivity. This method relies on magnetic Dynabeads containing antibodies and nanoparticles that are loaded both with DNA barcords and with antibodies that can sandwich the target protein captured by the Dynabead-bound antibodies. The aggregate sandwich structures are magnetically separated from the solution and treated to remove the conjugated barcode DNA. The DNA barcodes are then identified by SERS and PCR analysis. The concentration of norepinephrine in dopaminergic cells can be readily detected using the bio-barcode assay, which is a rapid, high-throughput screening tool for detecting neurotransmitters.
Detection of dopamine in dopaminergic cell using nanoparticles-based barcode DNA analysis.
An, Jeung Hee; Kim, Tae-Hyung; Oh, Byung-Keun; Choi, Jeong Woo
2012-01-01
Nanotechnology-based bio-barcode-amplification analysis may be an innovative approach to dopamine detection. In this study, we evaluated the efficacy of this bio-barcode DNA method in detecting dopamine from dopaminergic cells. Herein, a combination DNA barcode and bead-based immunoassay for neurotransmitter detection with PCR-like sensitivity is described. This method relies on magnetic nanoparticles with antibodies and nanoparticles that are encoded with DNA, and antibodies that can sandwich the target protein captured by the nanoparticle-bound antibodies. The aggregate sandwich structures are magnetically separated from solution, and treated in order to remove the conjugated barcode DNA. The DNA barcodes were then identified via PCR analysis. The dopamine concentration in dopaminergic cells can be readily and rapidly detected via the bio-barcode assay method. The bio-barcode assay method is, therefore, a rapid and high-throughput screening tool for the detection of neurotransmitters such as dopamine.
49 CFR 192.625 - Odorization of gas.
Code of Federal Regulations, 2011 CFR
2011-10-01
... concentration in air of one-fifth of the lower explosive limit, the gas is readily detectable by a person with a... activity of a catalyst; or (C) Reduces the percentage completion of a chemical reaction; (3) In the case of... be exposed. (d) The odorant may not be soluble in water to an extent greater than 2.5 parts to 100...
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander M.; Benson, Scott C.
1999-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander M.; Benson, Scott C.
1998-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander N.; Benson, Scott C.
1995-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander N.; Benson, Scott C.
1997-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
Oxidation of Ethylene Glycol by a Salt-Requiring Bacterium
Caskey, William H.; Taber, Willard A.
1981-01-01
Bacterium T-52, cultured on ethylene glycol, readily oxidized glycolate and glyoxylate and exhibited elevated activities of ethylene glycol dehydrogenase and glycolate oxidase. Labeled glyoxylate was identified in reaction mixtures containing [14C]-ethylene glycol, but no glycolate was detected. The most likely pathway of ethylene glycol catabolism by bacterium T-52 is sequential oxidation to glycolate and glyoxylate. PMID:16345810
NASA Technical Reports Server (NTRS)
Ahearn, D. G.; Simmons, R. B.; Switzer, K. F.; Ajello, L.; Pierson, D. L.
1991-01-01
Cladosporium cladosporioides and C. hebarum colonized painted metal surfaces of covering panels and register vents of heating, air conditioning and ventilation systems. Hyphae penetrated the paint film and developed characteristic conidiophores and conidia. The colonies were tightly appressed to the metal surface and conidia were not readily detectable via standard air sampling procedures.
Astrometric Detection of a Low Mass Companion Orbiting the Star AB Doradus
NASA Technical Reports Server (NTRS)
Soderhjelm, S.; Guirado, J. C.; Reynolds, J. E.; Lestrade, J. F.; Preston, R. A.; Jauncey, D. L.; Jones, D. L.; Tzioumis, A. K.; Ferris, R. H.; King, E. A.;
1997-01-01
We report submilliarsecond-precise astrometric measurement for the late-type star AB Doradus via a combination of VLBI (very long baseline interferometry) and Hipparos satellite data. Our astrometric analysis results in the precise determination of the kinematics of this star, that reveals an orbital motion readily explained as caused by the gravitational interaction with a low-mass companion.
2012-11-01
vitamin B12. Additionally, a reductant reacts directly with hexavalent chromium to reduce it to the trivalent state. SRS®-M provides a readily...experiments ......................................................................... 27 Figure 8. Hexavalent chromium detected in ISMA effluent post in situ...ground surface cis-DCE cis-dichloroethene CERCLA Comprehensive Environmental Response, Compensation, and Liability Act Cr(VI) hexavalent chromium
Crystallization of Stretched Polyimides: A Structure-Property Study
NASA Technical Reports Server (NTRS)
Hinkley, Jeffrey A.; Dezern, James F.
2002-01-01
A simple rotational isomeric state model was used to detect the degree to which polyimide repeat units might align to give an extended crystal. It was found experimentally that the hallmarks of stretch-crystallization were more likely to occur in materials whose molecules could readily give extended, aligned conformations. A proposed screening criterion was 84% accurate in selecting crystallizing molecules.
"Is My Child Developing Normally?": A Critical Review of Web-Based Resources for Parents
ERIC Educational Resources Information Center
Williams, Nia; Mughal, Sabena; Blair, Mitch
2008-01-01
Early detection of developmental problems improves outcomes for parents and children. Parents want to be involved in assessment and need high-quality, accurate, and reliable data on child development to help monitor progress and inform decisions on referral. The aim of this paper is to review which websites are readily accessible to parents on…
Shulman, Nancy S; Delgado, Jamael; Bosch, Ronald J; Winters, Mark A; Johnston, Elizabeth; Shafer, Robert W; Katzenstein, David A; Merigan, Thomas C
2005-05-01
HIV-1 isolates harboring multiple nucleoside reverse transcriptase inhibitor (NRTI) resistance mutations are more susceptible ("hypersusceptible") to the nonnucleoside reverse transcriptase inhibitors (NNRTIs) than isolates lacking NRTI resistance mutations, but this has only been reported with a single-cycle replication phenotypic assay. In fact, there was a report that a commercial multicycle assay did not readily detect hypersusceptibility. To see whether NNRTI hypersusceptibility can be demonstrated in other types of phenotypic assays, including multicycle assays and enzyme inhibition assays. The susceptibility of HIV-1 clones derived from different patients in multicycle assays was tested in peripheral blood mononuclear cells (PBMCs) and in an established cell line. In addition, the reverse transcriptase (RT) of many of these clones was expressed and their susceptibility tested in an RT inhibition assay. Nevirapine and efavirenz susceptibilities were tested and compared with a control wild-type virus or RT. Hypersusceptibility to nevirapine and efavirenz was detected using each of the methods described above. R values correlating the other methods with single-cycle assay values were between 0.66 and 0.96. In addition to the high correlations, the different methods gave similar numeric results. NNRTI hypersusceptibility is readily seen in multicycle susceptibility assays and in enzyme inhibition assays.
Binding Isotherms and Time Courses Readily from Magnetic Resonance.
Xu, Jia; Van Doren, Steven R
2016-08-16
Evidence is presented that binding isotherms, simple or biphasic, can be extracted directly from noninterpreted, complex 2D NMR spectra using principal component analysis (PCA) to reveal the largest trend(s) across the series. This approach renders peak picking unnecessary for tracking population changes. In 1:1 binding, the first principal component captures the binding isotherm from NMR-detected titrations in fast, slow, and even intermediate and mixed exchange regimes, as illustrated for phospholigand associations with proteins. Although the sigmoidal shifts and line broadening of intermediate exchange distorts binding isotherms constructed conventionally, applying PCA directly to these spectra along with Pareto scaling overcomes the distortion. Applying PCA to time-domain NMR data also yields binding isotherms from titrations in fast or slow exchange. The algorithm readily extracts from magnetic resonance imaging movie time courses such as breathing and heart rate in chest imaging. Similarly, two-step binding processes detected by NMR are easily captured by principal components 1 and 2. PCA obviates the customary focus on specific peaks or regions of images. Applying it directly to a series of complex data will easily delineate binding isotherms, equilibrium shifts, and time courses of reactions or fluctuations.
Wang, Xiaoyan; Yu, Jialuo; Wu, Xiaqing; Fu, Junqing; Kang, Qi; Shen, Dazhong; Li, Jinhua; Chen, Lingxin
2016-07-15
A novel molecular imprinting-based turn-on ratiometric fluorescence sensor was constructed via a facile sol-gel polymerization for detection of 2,4-dichlorophenoxyacetic acid (2,4-D) on the basis of photoinduced electron transfer (PET) by using nitrobenzoxadiazole (NBD) as detection signal source and quantum dots (QDs) as reference signal source. With the presence and increase of 2,4-D, the amine groups on the surface of QDs@SiO2 could bind with 2,4-D and thereby the NBD fluorescence intensities could be significantly enhanced since the PET process was inhibited, while the QDs maintained constant intensities. Accordingly, the ratio of the dual-emission intensities of green NBD and red QDs could be utilized for turn-on fluorescent detection of 2,4-D, along with continuous color changes from orange-red to green readily observed by the naked eye. The as-prepared fluorescence sensor obtained high sensitivity with a low detection limit of 0.14μM within 5min, and distinguished recognition selectivity for 2,4-D over its analogs. Moreover, the sensor was successfully applied to determine 2,4-D in real water samples, and high recoveries at three spiking levels of 2,4-D ranged from 95.0% to 110.1% with precisions below 4.5%. The simple, rapid and reliable visual sensing strategy would not only provide potential applications for high selective ultratrace analysis of complicated matrices, but also greatly enrich the research connotations of molecularly imprinted sensors. Copyright © 2016 Elsevier B.V. All rights reserved.
Rho, Jin Kyung; Lee, Hyangsin; Park, Chan-Sik; Choi, Chang-Min; Lee, Jae Cheol
2013-09-01
EML4-ALK fusion oncogene has emerged as a novel molecular target in non-small cell lung cancer (NSCLC). Although break-apart fluorescent in situ hybridization (FISH) is the standard method for diagnosis, it is expensive, not readily available and sometimes difficult to interpret. In addition, ALK immunohistochemistry (IHC) may miss the diagnosis because of relatively low level of ALK transcription. In situ proximity ligation assay (PLA) originally developed for precise detection and quantification of proteins by dual recognition and amplification process was used for sensitive detection of EML4-ALK fusion oncoprotein in NSCLC cell lines (ALK negative cell: PC-9 and H460, ALK positive cell: H3122 and H2228). EML4-ALK oncogene and protein in lung cancer cells were confirmed by multiplex RT-PCR and Western blots. We detected 117 kDa variant 1 of EML4-ALK in H3122 and 90 kDa variant 3 of EML4-ALK in H2228. These cells were more sensitive to crizotinib, an ALK inhibitor compared with PC-9 and H460 cells without EML4-ALK rearrangement. After fixing on glass slides by cytospin centrifuge, in situ PLA test was performed. Among four cell lines, distinct, tiny spots were visible only in H3122 and H2228 cell lines with ALK rearrangement. The same results were also obtained when paraffin-embedded cell blocks were used. Highly specific and sensitive detection of EML4-ALK fusion oncoprotein is possible by in situ PLA method suggesting its clinical application.
External validation of EPIWIN biodegradation models.
Posthumus, R; Traas, T P; Peijnenburg, W J G M; Hulzebos, E M
2005-01-01
The BIOWIN biodegradation models were evaluated for their suitability for regulatory purposes. BIOWIN includes the linear and non-linear BIODEG and MITI models for estimating the probability of rapid aerobic biodegradation and an expert survey model for primary and ultimate biodegradation estimation. Experimental biodegradation data for 110 newly notified substances were compared with the estimations of the different models. The models were applied separately and in combinations to determine which model(s) showed the best performance. The results of this study were compared with the results of other validation studies and other biodegradation models. The BIOWIN models predict not-readily biodegradable substances with high accuracy in contrast to ready biodegradability. In view of the high environmental concern of persistent chemicals and in view of the large number of not-readily biodegradable chemicals compared to the readily ones, a model is preferred that gives a minimum of false positives without a corresponding high percentage false negatives. A combination of the BIOWIN models (BIOWIN2 or BIOWIN6) showed the highest predictive value for not-readily biodegradability. However, the highest score for overall predictivity with lowest percentage false predictions was achieved by applying BIOWIN3 (pass level 2.75) and BIOWIN6.
Use of molecular binding pair technology for definitive product marking and identification
NASA Astrophysics Data System (ADS)
Rittenburg, James H.
1998-04-01
Counterfeiting and diversion of brand name products is a significant worldwide problem. Loss of revenue to the manufacturers is obviously important, however erosion of consumer confidence, and liability for adverse health effects or performance caused by poor quality product can be of even greater significance. Biocode has developed a novel approach to product marking and identification that utilizes molecular binding pair technologies such as immunoassay. The sensitivity, specificity, and ease of use of immunoassay provides a powerful method for detecting trace levels of intentionally added chemical markers. Using the diversity of the immune response, Biocode has developed a library of binding molecules and highly sensitive immunoassay systems for detection and measurement of a variety of chemical markers. The markers have been selected based on their stability and compatibility within various types of products. For food, beverage, and pharmaceutical applications, common and naturally occurring food ingredients and pharmaceutical excipients provide markers which are safe, readily available, and already approved for use. For other applications such as fuel and lubricant marking. Solubility and chemical stability of the markers are a major consideration. In addition to incorporating markers directly into products, Biocode has also developed invisible inks that can be printed onto the surface of products, packaging, or labels. The trace levels of marker that is printed onto the surface of a product or package can only be revealed by using the complementary binding pair that has been developed by Biocode. This technology provides for simple field tests and very high level of security as it is virtually impossible to copy.
Applications of Aptamers as Sensors
NASA Astrophysics Data System (ADS)
Cho, Eun Jeong; Lee, Joo-Woon; Ellington, Andrew D.
2009-07-01
Aptamers are ligand-binding nucleic acids whose affinities and selectivities can rival those of antibodies. They have been adapted to analytical applications not only as alternatives to antibodies, but as unique reagents in their own right. In particular, aptamers can be readily site-specifically modified during chemical or enzymatic synthesis to incorporate particular reporters, linkers, or other moieties. Also, aptamer secondary structures can be engineered to undergo analyte-dependent conformational changes, which, in concert with the ability to specifically place chemical agents, opens up a wealth of possible signal transduction schemas, irrespective of whether the detection modality is optical, electrochemical, or mass based. Finally, because aptamers are nucleic acids, they are readily adapted to sequence- (and hence signal-) amplification methods. However, application of aptamers without a basic knowledge of their biochemistry or technical requirements can cause serious analytical difficulties.
Noncontact measurement of emotional and physiological changes in heart rate from a webcam.
Madan, Christopher R; Harrison, Tyler; Mathewson, Kyle E
2018-04-01
Heart rate, measured in beats per minute, can be used as an index of an individual's physiological state. Each time the heart beats, blood is expelled and travels through the body. This blood flow can be detected in the face using a standard webcam that is able to pick up subtle changes in color that cannot be seen by the naked eye. Due to the light absorption spectrum of blood, we are able to detect differences in the amount of light absorbed by the blood traveling just below the skin (i.e., photoplethysmography). By modulating emotional and physiological stress-that is, viewing arousing images and sitting versus standing, respectively-to elicit changes in heart rate, we explored the feasibility of using a webcam as a psychophysiological measurement of autonomic activity. We found a high level of agreement between established physiological measures, electrocardiogram, and blood pulse oximetry, and heart rate estimates obtained from the webcam. We thus suggest webcams can be used as a noninvasive and readily available method for measuring psychophysiological changes, easily integrated into existing stimulus presentation software and hardware setups. © 2017 Society for Psychophysiological Research.
Intranasal Localizability of Odorants: Influence of Stimulus Volume
Frasnelli, J.; Berg, J.; Huang, G.; Doty, R.L.
2011-01-01
When an odorant is presented to one side of the nose and air to the other, the ability to localize which side received the odorant depends upon trigeminal nerve stimulation. It has been shown that performance on this lateralization task increases as stimulus concentration increases. In this study, we determined the influences of stimulus volume and sex on the ability to localize each of 8 odorants presented at neat concentrations: anethole, geraniol, limonene, linalool, menthol, methyl salicyclate, phenyl ethanol, and vanillin. At a low stimulus volume (11 mL), only menthol was localized at an above-chance level. At a high stimulus volume (21 mL), above-chance localization occurred for all odorants except vanillin. Women were significantly better than men in localizing menthol. Stimuli rated as most intense were those that were most readily localized. The detection performance measures, as well as rated intensity values, significantly correlated with earlier findings of the trigeminal detectability of odorants presented to anosmic and normosmic subjects. This study suggests that differences in stimulus volume may explain some discrepant findings within the trigeminal chemosensory literature and supports the concept that vanillin may be a “relatively pure” olfactory stimulus. PMID:21310764
Intranasal localizability of odorants: influence of stimulus volume.
Frasnelli, J; Hummel, T; Berg, J; Huang, G; Doty, R L
2011-05-01
When an odorant is presented to one side of the nose and air to the other, the ability to localize which side received the odorant depends upon trigeminal nerve stimulation. It has been shown that performance on this lateralization task increases as stimulus concentration increases. In this study, we determined the influences of stimulus volume and sex on the ability to localize each of 8 odorants presented at neat concentrations: anethole, geraniol, limonene, linalool, menthol, methyl salicylate, phenyl ethanol, and vanillin. At a low stimulus volume (11 mL), only menthol was localized at an above-chance level. At a high stimulus volume (21 mL), above-chance localization occurred for all odorants except vanillin. Women were significantly better than men in localizing menthol. Stimuli rated as most intense were those that were most readily localized. The detection performance measures, as well as rated intensity values, significantly correlated with earlier findings of the trigeminal detectability of odorants presented to anosmic and normosmic subjects. This study suggests that differences in stimulus volume may explain some discrepant findings within the trigeminal chemosensory literature and supports the concept that vanillin may be a "relatively pure" olfactory stimulus.
Grau, Frederic R; Schroeder, Megan E; Mulhern, Erin L; McIntosh, Michael T; Bounpheng, Mangkey A
2015-03-01
African swine fever (ASF), classical swine fever (CSF), and foot-and-mouth disease (FMD) are highly contagious animal diseases of significant economic importance. Pigs infected with ASF and CSF viruses (ASFV and CSFV) develop clinical signs that may be indistinguishable from other diseases. Likewise, various causes of vesicular disease can mimic clinical signs caused by the FMD virus (FMDV). Early detection is critical to limiting the impact and spread of these disease outbreaks, and the ability to perform herd-level surveillance for all 3 diseases rapidly and cost effectively using a single diagnostic sample and test is highly desirable. This study assessed the feasibility of simultaneous ASFV, CSFV, and FMDV detection by multiplex reverse transcription real-time polymerase chain reaction (mRT-qPCR) in swine oral fluids collected through the use of chewing ropes. Animal groups were experimentally infected independently with each virus, observed for clinical signs, and oral fluids collected and tested throughout the course of infection. All animal groups chewed on the ropes readily before and after onset of clinical signs and before onset of lameness or serious clinical signs. ASFV was detected as early as 3 days postinoculation (dpi), 2-3 days before onset of clinical disease; CSFV was detected at 5 dpi, coincident with onset of clinical disease; and FMDV was detected as early as 1 dpi, 1 day before the onset of clinical disease. Equivalent results were observed in 4 independent studies and demonstrate the feasibility of oral fluids and mRT-qPCR for surveillance of ASF, CSF, and FMD in swine populations. © 2015 The Author(s).
Debaize, Lydie; Jakobczyk, Hélène; Rio, Anne-Gaëlle; Gandemer, Virginie; Troadec, Marie-Bérengère
2017-01-01
Genetic abnormalities, including chromosomal translocations, are described for many hematological malignancies. From the clinical perspective, detection of chromosomal abnormalities is relevant not only for diagnostic and treatment purposes but also for prognostic risk assessment. From the translational research perspective, the identification of fusion proteins and protein interactions has allowed crucial breakthroughs in understanding the pathogenesis of malignancies and consequently major achievements in targeted therapy. We describe the optimization of the Proximity Ligation Assay (PLA) to ascertain the presence of fusion proteins, and protein interactions in non-adherent pre-B cells. PLA is an innovative method of protein-protein colocalization detection by molecular biology that combines the advantages of microscopy with the advantages of molecular biology precision, enabling detection of protein proximity theoretically ranging from 0 to 40 nm. We propose an optimized PLA procedure. We overcome the issue of maintaining non-adherent hematological cells by traditional cytocentrifugation and optimized buffers, by changing incubation times, and modifying washing steps. Further, we provide convincing negative and positive controls, and demonstrate that optimized PLA procedure is sensitive to total protein level. The optimized PLA procedure allows the detection of fusion proteins and protein interactions on non-adherent cells. The optimized PLA procedure described here can be readily applied to various non-adherent hematological cells, from cell lines to patients' cells. The optimized PLA protocol enables detection of fusion proteins and their subcellular expression, and protein interactions in non-adherent cells. Therefore, the optimized PLA protocol provides a new tool that can be adopted in a wide range of applications in the biological field.
Zhu, Shengchao; Zhang, Qin; Guo, Liang-Hong
2008-08-22
Fluorescent organic dyes are currently the standard signal-generating labels used in microarray quantification. However, new labeling strategies are needed to meet the demand for high sensitivity in the detection of low-abundance proteins and small molecules. In this report, a long-chain DNA/dye conjugate was used to attach multiple fluorescence labels on antibodies to improve signal intensity and immunoassay sensitivity. Compared with the 30 base-pair (bp) oligonucleotide used in our previous work [Q. Zhang, L.-H. Guo, Bioconjugate Chem. 18 (2007) 1668-1672], conjugation of a 219 bp DNA in solution with a fluorescent DNA binder SYBR Green I resulted in more than sixfold increase in signal intensity, consistent with the increase in bp number. In a direct immunoassay for the detection of goat anti-mouse IgG in a mouse IgG-coated 96-well plate, the long DNA conjugate label also produced higher fluorescence than the short one, accompanied by about 15-fold improvement in the detection limit. To demonstrate its advantage in real applications, the DNA/dye conjugate was employed in the competitive immunoassay of 17beta-estradiol, a clinically and environmentally important analyte. The biotin-terminated DNA was attached to biotinylated anti-estradiol antibody through the biotin/streptavidin/biotin bridge after the immuno-reaction was completed, followed by conjugation with SYBR Green I. The limit of detection for 17beta-estradiol is 1.9 pg mL(-1), which is 200-fold lower than the assay using fluorescein-labeled antibodies. The new multiple labeling strategy uses readily available reagents, and is also compatible with current biochip platform. It has great potential in the sensitive detection of protein and antibody microarrays.
False Negatives for Remote Life Detection on Ocean-Bearing Planets: Lessons from the Early Earth.
Reinhard, Christopher T; Olson, Stephanie L; Schwieterman, Edward W; Lyons, Timothy W
2017-04-01
Ocean-atmosphere chemistry on Earth has undergone dramatic evolutionary changes throughout its long history, with potentially significant ramifications for the emergence and long-term stability of atmospheric biosignatures. Though a great deal of work has centered on refining our understanding of false positives for remote life detection, much less attention has been paid to the possibility of false negatives, that is, cryptic biospheres that are widespread and active on a planet's surface but are ultimately undetectable or difficult to detect in the composition of a planet's atmosphere. Here, we summarize recent developments from geochemical proxy records and Earth system models that provide insight into the long-term evolution of the most readily detectable potential biosignature gases on Earth-oxygen (O 2 ), ozone (O 3 ), and methane (CH 4 ). We suggest that the canonical O 2 -CH 4 disequilibrium biosignature would perhaps have been challenging to detect remotely during Earth's ∼4.5-billion-year history and that in general atmospheric O 2 /O 3 levels have been a poor proxy for the presence of Earth's biosphere for all but the last ∼500 million years. We further suggest that detecting atmospheric CH 4 would have been problematic for most of the last ∼2.5 billion years of Earth's history. More broadly, we stress that internal oceanic recycling of biosignature gases will often render surface biospheres on ocean-bearing silicate worlds cryptic, with the implication that the planets most conducive to the development and maintenance of a pervasive biosphere will often be challenging to characterize via conventional atmospheric biosignatures. Key Words: Biosignatures-Oxygen-Methane-Ozone-Exoplanets-Planetary habitability. Astrobiology 17, 287-297.
False Negatives for Remote Life Detection on Ocean-Bearing Planets: Lessons from the Early Earth
Olson, Stephanie L.; Schwieterman, Edward W.; Lyons, Timothy W.
2017-01-01
Abstract Ocean-atmosphere chemistry on Earth has undergone dramatic evolutionary changes throughout its long history, with potentially significant ramifications for the emergence and long-term stability of atmospheric biosignatures. Though a great deal of work has centered on refining our understanding of false positives for remote life detection, much less attention has been paid to the possibility of false negatives, that is, cryptic biospheres that are widespread and active on a planet's surface but are ultimately undetectable or difficult to detect in the composition of a planet's atmosphere. Here, we summarize recent developments from geochemical proxy records and Earth system models that provide insight into the long-term evolution of the most readily detectable potential biosignature gases on Earth—oxygen (O2), ozone (O3), and methane (CH4). We suggest that the canonical O2-CH4 disequilibrium biosignature would perhaps have been challenging to detect remotely during Earth's ∼4.5-billion-year history and that in general atmospheric O2/O3 levels have been a poor proxy for the presence of Earth's biosphere for all but the last ∼500 million years. We further suggest that detecting atmospheric CH4 would have been problematic for most of the last ∼2.5 billion years of Earth's history. More broadly, we stress that internal oceanic recycling of biosignature gases will often render surface biospheres on ocean-bearing silicate worlds cryptic, with the implication that the planets most conducive to the development and maintenance of a pervasive biosphere will often be challenging to characterize via conventional atmospheric biosignatures. Key Words: Biosignatures—Oxygen—Methane—Ozone—Exoplanets—Planetary habitability. Astrobiology 17, 287–297. PMID:28418704
The use of interaural parameters during incoherence detection in reproducible noise
NASA Astrophysics Data System (ADS)
Goupell, Matthew Joseph
Interaural incoherence is a measure of the dissimilarity of the signals in the left and right ears. It is important in a number of acoustical phenomenon such as a listener's sensation envelopment and apparent source width in room acoustics, speech intelligibility, and binaural release from energetic masking. Humans are incredibly sensitive to the difference between perfectly coherent and slightly incoherent signals, however the nature of this sensitivity is not well understood. The purpose of this dissertation is to understand what parameters are important to incoherence detection. Incoherence is perceived to have time-varying characteristics. It is conjectured that incoherence detection is performed by a process that takes this time dependency into account. Left-ear-right-ear noise-pairs were generated, all with a fixed value of interaural coherence, 0.9922. The noises had a center frequency of 500 Hz, a bandwidth of 14 Hz, and a duration of 500 ms. Listeners were required to discriminate between these slightly incoherent noises and diotic noises, with a coherence of 1.0. It was found that the value of interaural incoherence itself was an inadequate predictor of discrimination. Instead, incoherence was much more readily detected for those noise-pairs with the largest fluctuations in interaural phase and level differences (as measured by the standard deviation). Noise-pairs with the same value of coherence, and geometric mean frequency of 500 Hz were also generated for bandwidths of 108 Hz and 2394 Hz. It was found that for increasing bandwidth, fluctuations in interaural differences varied less between different noise-pairs and that detection performance varied less as well. The results suggest that incoherence detection is based on the size and the speed of interaural fluctuations and that the value of coherence itself predicts performance only in the wide-band limit where different particular noises with the same incoherence have similar fluctuations. Noise-pairs with short durations of 100, 50, and 25 ms, and bandwidth of 14 Hz, and a coherence of 0.9922 were used to test if a short-term incoherence function is used in incoherence detection. It was found that listeners could significantly use fluctuations of phase and level to detect incoherence for all three of these short durations. Therefore, a short-term coherence function is not used to detect incoherence. For the smallest duration of 25 ms, listeners' detection cue sometimes changed from a "width" cue to a lateralization cue. Modeling of the data was performed. Ten different binaural models were tested against detection data for 14-Hz and 108-Hz bandwidths. These models included different types of binaural processing: independent interaural phase and level differences, lateral position, and short-term cross-correlation. Several preprocessing features were incorporated in the models: compression, temporal averaging, and envelope weighting. For the 14-Hz bandwidth data, the most successful model assumed independent centers for interaural phase and interaural level processing, and this model correlated with detectability at r = 0.87. That model also described the data best when it was assumed that interaural phase fluctuations and interaural level fluctuations contribute approximately equally to incoherence detection. For the 108-Hz bandwidth data, detection performance varied much less among different waveforms, and the data were less able to distinguish between models.
Detailed Performance Calculations: Wayne State University and Ford Motor Company, Appendix C
NASA Technical Reports Server (NTRS)
1984-01-01
The laser-generated OH through ozone dissociation is defined in equations. Using these equations, the ozone interference levels corresponding to various humidity and ozone concentrations can be calculated readily.
Detailed performance calculations: Wayne State University and Ford Motor Company, appendix C
NASA Astrophysics Data System (ADS)
1984-12-01
The laser-generated OH through ozone dissociation is defined in equations. Using these equations, the ozone interference levels corresponding to various humidity and ozone concentrations can be calculated readily.
Digital readout for image converter cameras
NASA Astrophysics Data System (ADS)
Honour, Joseph
1991-04-01
There is an increasing need for fast and reliable analysis of recorded sequences from image converter cameras so that experimental information can be readily evaluated without recourse to more time consuming photographic procedures. A digital readout system has been developed using a randomly triggerable high resolution CCD camera, the output of which is suitable for use with IBM AT compatible PC. Within half a second from receipt of trigger pulse, the frame reformatter displays the image and transfer to storage media can be readily achieved via the PC and dedicated software. Two software programmes offer different levels of image manipulation which includes enhancement routines and parameter calculations with accuracy down to pixel levels. Hard copy prints can be acquired using a specially adapted Polaroid printer, outputs for laser and video printer extend the overall versatility of the system.
Kotterman, Michiel J. J.; Vis, Eric H.; Field, Jim A.
1998-01-01
White rot fungi can oxidize high-molecular-weight polycyclic aromatic hydrocarbons (PAH) rapidly to polar metabolites, but only limited mineralization takes place. The objectives of this study were to determine if the polar metabolites can be readily mineralized by indigenous microflora from several inoculum sources, such as activated sludge, forest soils, and PAH-adapted sediment sludge, and to determine if such metabolites have decreased mutagenicity compared to the mutagenicity of the parent PAH. 14C-radiolabeled benzo[a]pyrene was subjected to oxidation by the white rot fungus Bjerkandera sp. strain BOS55. After 15 days, up to 8.5% of the [14C]benzo[a]pyrene was recovered as 14CO2 in fungal cultures, up to 73% was recovered as water-soluble metabolites, and only 4% remained soluble in dibutyl ether. Thin-layer chromatography analysis revealed that many polar fluorescent metabolites accumulated. Addition of indigenous microflora to fungal cultures with oxidized benzo[a]pyrene on day 15 resulted in an initially rapid increase in the level of 14CO2 recovery to a maximal value of 34% by the end of the experiments (>150 days), and the level of water-soluble label decreased to 16% of the initial level. In fungal cultures not inoculated with microflora, the level of 14CO2 recovery increased to 13.5%, while the level of recovery of water-soluble metabolites remained as high as 61%. No large differences in 14CO2 production were observed with several inocula, showing that some polar metabolites of fungal benzo[a]pyrene oxidation were readily degraded by indigenous microorganisms, while other metabolites were not. Of the inocula tested, only PAH-adapted sediment sludge was capable of directly mineralizing intact benzo[a]pyrene, albeit at a lower rate and to a lesser extent than the mineralization observed after combined treatment with white rot fungi and indigenous microflora. Fungal oxidation of benzo[a]pyrene resulted in rapid and almost complete elimination of its high mutagenic potential, as observed in the Salmonella typhimurium revertant test performed with strains TA100 and TA98. Moreover, no direct mutagenic metabolite could be detected during fungal oxidation. The remaining weak mutagenic activity of fungal cultures containing benzo[a]pyrene metabolites towards strain TA98 was further decreased by subsequent incubations with indigenous microflora. PMID:9687440
Competitive evaluation of failure detection algorithms for strapdown redundant inertial instruments
NASA Technical Reports Server (NTRS)
Wilcox, J. C.
1973-01-01
Algorithms for failure detection, isolation, and correction of redundant inertial instruments in the strapdown dodecahedron configuration are competitively evaluated in a digital computer simulation that subjects them to identical environments. Their performance is compared in terms of orientation and inertial velocity errors and in terms of missed and false alarms. The algorithms appear in the simulation program in modular form, so that they may be readily extracted for use elsewhere. The simulation program and its inputs and outputs are described. The algorithms, along with an eight algorithm that was not simulated, also compared analytically to show the relationships among them.
Development and validation of a comprehensive genomic diagnostic tool for myeloid malignancies
McKerrell, Thomas; Moreno, Thaidy; Ponstingl, Hannes; Bolli, Niccolo; Dias, João M. L.; Tischler, German; Colonna, Vincenza; Manasse, Bridget; Bench, Anthony; Bloxham, David; Herman, Bram; Fletcher, Danielle; Park, Naomi; Quail, Michael A.; Manes, Nicla; Hodkinson, Clare; Baxter, Joanna; Sierra, Jorge; Foukaneli, Theodora; Warren, Alan J.; Chi, Jianxiang; Costeas, Paul; Rad, Roland; Huntly, Brian; Grove, Carolyn; Ning, Zemin; Tyler-Smith, Chris; Varela, Ignacio; Scott, Mike; Nomdedeu, Josep; Mustonen, Ville
2016-01-01
The diagnosis of hematologic malignancies relies on multidisciplinary workflows involving morphology, flow cytometry, cytogenetic, and molecular genetic analyses. Advances in cancer genomics have identified numerous recurrent mutations with clear prognostic and/or therapeutic significance to different cancers. In myeloid malignancies, there is a clinical imperative to test for such mutations in mainstream diagnosis; however, progress toward this has been slow and piecemeal. Here we describe Karyogene, an integrated targeted resequencing/analytical platform that detects nucleotide substitutions, insertions/deletions, chromosomal translocations, copy number abnormalities, and zygosity changes in a single assay. We validate the approach against 62 acute myeloid leukemia, 50 myelodysplastic syndrome, and 40 blood DNA samples from individuals without evidence of clonal blood disorders. We demonstrate robust detection of sequence changes in 49 genes, including difficult-to-detect mutations such as FLT3 internal-tandem and mixed-lineage leukemia (MLL) partial-tandem duplications, and clinically significant chromosomal rearrangements including MLL translocations to known and unknown partners, identifying the novel fusion gene MLL-DIAPH2 in the process. Additionally, we identify most significant chromosomal gains and losses, and several copy neutral loss-of-heterozygosity mutations at a genome-wide level, including previously unreported changes such as homozygosity for DNMT3A R882 mutations. Karyogene represents a dependable genomic diagnosis platform for translational research and for the clinical management of myeloid malignancies, which can be readily adapted for use in other cancers. PMID:27121471
CTC-mRNA (AR-V7) Analysis from Blood Samples—Impact of Blood Collection Tube and Storage Time
Luk, Alison W. S.; Ma, Yafeng; Ding, Pei N.; Young, Francis P.; Chua, Wei; Balakrishnar, Bavanthi; Dransfield, Daniel T.; de Souza, Paul; Becker, Therese M.
2017-01-01
Circulating tumour cells (CTCs) are an emerging resource for monitoring cancer biomarkers. New technologies for CTC isolation and biomarker detection are increasingly sensitive, however, the ideal blood storage conditions to preserve CTC-specific mRNA biomarkers remains undetermined. Here we tested the preservation of tumour cells and CTC-mRNA over time in common anticoagulant ethylene-diamine-tetra-acetic acid (EDTA) and acid citrate dextrose solution B (Citrate) blood tubes compared to preservative-containing blood tubes. Blood samples spiked with prostate cancer cells were processed after 0, 24, 30, and 48 h storage at room temperature. The tumour cell isolation efficiency and the mRNA levels of the prostate cancer biomarkers androgen receptor variant 7 (AR-V7) and total AR, as well as epithelial cell adhesion molecule (EpCAM) were measured. Spiked cells were recovered across all storage tube types and times. Surprisingly, tumour mRNA biomarkers were readily detectable after 48 h storage in EDTA and Citrate tubes, but not in preservative-containing tubes. Notably, AR-V7 expression was detected in prostate cancer patient blood samples after 48 h storage in EDTA tubes at room temperature. This important finding presents opportunities for measuring AR-V7 expression from clinical trial patient samples processed within 48 h—a much more feasible timeframe compared to previous recommendations. PMID:28498319
NASA Astrophysics Data System (ADS)
Chen, Jian; Randall, Robert Bond; Peeters, Bart
2016-06-01
Artificial Neural Networks (ANNs) have the potential to solve the problem of automated diagnostics of piston slap faults, but the critical issue for the successful application of ANN is the training of the network by a large amount of data in various engine conditions (different speed/load conditions in normal condition, and with different locations/levels of faults). On the other hand, the latest simulation technology provides a useful alternative in that the effect of clearance changes may readily be explored without recourse to cutting metal, in order to create enough training data for the ANNs. In this paper, based on some existing simplified models of piston slap, an advanced multi-body dynamic simulation software was used to simulate piston slap faults with different speeds/loads and clearance conditions. Meanwhile, the simulation models were validated and updated by a series of experiments. Three-stage network systems are proposed to diagnose piston faults: fault detection, fault localisation and fault severity identification. Multi Layer Perceptron (MLP) networks were used in the detection stage and severity/prognosis stage and a Probabilistic Neural Network (PNN) was used to identify which cylinder has faults. Finally, it was demonstrated that the networks trained purely on simulated data can efficiently detect piston slap faults in real tests and identify the location and severity of the faults as well.
Infrared vibrational spectroscopy: a rapid and novel diagnostic and monitoring tool for cystinuria
Oliver, Katherine V.; Vilasi, Annalisa; Maréchal, Amandine; Moochhala, Shabbir H.; Unwin, Robert J.; Rich, Peter R.
2016-01-01
Cystinuria is the commonest inherited cause of nephrolithiasis (~1% in adults; ~6% in children) and is the result of impaired cystine reabsorption in the renal proximal tubule. Cystine is poorly soluble in urine with a solubility of ~1 mM and can readily form microcrystals that lead to cystine stone formation, especially at low urine pH. Diagnosis of cystinuria is made typically by ion-exchange chromatography (IEC) detection and quantitation, which is slow, laboursome and costly. More rapid and frequent monitoring of urinary cystine concentration would significantly improve the diagnosis and clinical management of cystinuria. We used attenuated total reflection - Fourier transform infrared spectroscopy (ATR-FTIR) to detect and quantitate insoluble cystine in 22 cystinuric and 5 healthy control urine samples. Creatinine concentration was also determined by ATR-FTIR to adjust for urinary concentration/dilution. Urine was centrifuged, the insoluble fraction re-suspended in 5 μL water and dried on the ATR prism. Cystine was quantitated using its 1296 cm−1 absorption band and levels matched with parallel measurements made using IEC. ATR-FTIR afforded a rapid and inexpensive method of detecting and quantitating insoluble urinary cystine. This proof-of-concept study provides a basis for developing a high-throughput, cost-effective diagnostic method for cystinuria, and for point-of-care clinical monitoring PMID:27721432
Carotenoid accumulation in orange-pigmented Capsicum annuum fruit, regulated at multiple levels
Rodriguez-Uribe, Laura; Guzman, Ivette; Rajapakse, Wathsala; Richins, Richard D.; O’Connell, Mary A.
2012-01-01
The pericarp of Capsicum fruit is a rich dietary source of carotenoids. Accumulation of these compounds may be controlled, in part, by gene transcription of biosynthetic enzymes. The carotenoid composition in a number of orange-coloured C. annuum cultivars was determined using HPLC and compared with transcript abundances for four carotenogenic enzymes, Psy, LcyB, CrtZ-2, and Ccs determined by qRT-PCR. There were unique carotenoid profiles as well as distinct patterns of transcription of carotenogenic enzymes within the seven orange-coloured cultivars. In one cultivar, ‘Fogo’, carrying the mutant ccs-3 allele, transcripts were detected for this gene, but no CCS protein accumulated. The premature stop termination in ccs-3 prevented expression of the biosynthetic activity to synthesize the capsanthin and capsorubin forms of carotenoids. In two other orange-coloured cultivars, ‘Orange Grande’ and ‘Oriole’, both with wild-type versions of all four carotenogenic enzymes, no transcripts for Ccs were detected and no red pigments accumulated. Finally, in a third case, the orange-coloured cultivar, Canary, transcripts for all four of the wild-type carotenogenic enzymes were readily detected yet no CCS protein appeared to accumulate and no red carotenoids were synthesized. In the past, mutations in Psy and Ccs have been identified as the loci controlling colour in the fruit. Now there is evidence that a non-structural gene may control colour development in Capsicum. PMID:21948863
Carotenoid accumulation in orange-pigmented Capsicum annuum fruit, regulated at multiple levels.
Rodriguez-Uribe, Laura; Guzman, Ivette; Rajapakse, Wathsala; Richins, Richard D; O'Connell, Mary A
2012-01-01
The pericarp of Capsicum fruit is a rich dietary source of carotenoids. Accumulation of these compounds may be controlled, in part, by gene transcription of biosynthetic enzymes. The carotenoid composition in a number of orange-coloured C. annuum cultivars was determined using HPLC and compared with transcript abundances for four carotenogenic enzymes, Psy, LcyB, CrtZ-2, and Ccs determined by qRT-PCR. There were unique carotenoid profiles as well as distinct patterns of transcription of carotenogenic enzymes within the seven orange-coloured cultivars. In one cultivar, 'Fogo', carrying the mutant ccs-3 allele, transcripts were detected for this gene, but no CCS protein accumulated. The premature stop termination in ccs-3 prevented expression of the biosynthetic activity to synthesize the capsanthin and capsorubin forms of carotenoids. In two other orange-coloured cultivars, 'Orange Grande' and 'Oriole', both with wild-type versions of all four carotenogenic enzymes, no transcripts for Ccs were detected and no red pigments accumulated. Finally, in a third case, the orange-coloured cultivar, Canary, transcripts for all four of the wild-type carotenogenic enzymes were readily detected yet no CCS protein appeared to accumulate and no red carotenoids were synthesized. In the past, mutations in Psy and Ccs have been identified as the loci controlling colour in the fruit. Now there is evidence that a non-structural gene may control colour development in Capsicum.
Nissan, Aviram; Stojadinovic, Alexander; Mitrani-Rosenbaum, Stella; Halle, David; Grinbaum, Ronit; Roistacher, Marina; Bochem, Andrea; Dayanc, Baris Emre; Ritter, Gerd; Gomceli, Ismail; Bostanci, Erdal Birol; Akoglu, Musa; Chen, Yao-Tseng; Old, Lloyd John; Gure, Ali Osmay
2012-04-01
Early detection of colorectal cancer (CRC) is currently based on fecal occult blood testing (FOBT) and colonoscopy, both which can significantly reduce CRC-related mortality. However, FOBT has low-sensitivity and specificity, whereas colonoscopy is labor- and cost-intensive. Therefore, the discovery of novel biomarkers that can be used for improved CRC screening, diagnosis, staging and as targets for novel therapies is of utmost importance. To identify novel CRC biomarkers we utilized representational difference analysis (RDA) and characterized a colon cancer associated transcript (CCAT1), demonstrating consistently strong expression in adenocarcinoma of the colon, while being largely undetectable in normal human tissues (p < 000.1). CCAT1 levels in CRC are on average 235-fold higher than those found in normal mucosa. Importantly, CCAT1 is strongly expressed in tissues representing the early phase of tumorigenesis: in adenomatous polyps and in tumor-proximal colonic epithelium, as well as in later stages of the disease (liver metastasis, for example). In CRC-associated lymph nodes, CCAT1 overexpression is detectable in all H&E positive, and 40.0% of H&E and immunohistochemistry negative lymph nodes, suggesting very high sensitivity. CCAT1 is also overexpressed in 40.0% of peripheral blood samples of patients with CRC but not in healthy controls. CCAT1 is therefore a highly specific and readily detectable marker for CRC and tumor-associated tissues. Copyright © 2011 UICC.
NASA Astrophysics Data System (ADS)
Choi, Seon-Ae; Park, Chul Soon; Kwon, Oh Seok; Giong, Hoi-Khoanh; Lee, Jeong-Soo; Ha, Tai Hwan; Lee, Chang-Soo
2016-05-01
Hydrogen sulfide (H2S) is an important biological messenger, but few biologically-compatible methods are available for its detection in aqueous solution. Herein, we report a highly water-soluble naphthalimide-based fluorescent probe (L1), which is a highly versatile building unit that absorbs and emits at long wavelengths and is selective for hydrogen sulfide over cysteine, glutathione, and other reactive sulfur, nitrogen, and oxygen species in aqueous solution. We describe turn-on fluorescent probes based on azide group reduction on the fluorogenic ‘naphthalene’ moiety to fluorescent amines and intracellular hydrogen sulfide detection without the use of an organic solvent. L1 and L2 were synthetically modified to functional groups with comparable solubility on the N-imide site, showing a marked change in turn-on fluorescent intensity in response to hydrogen sulfide in both PBS buffer and living cells. The probes were readily employed to assess intracellular hydrogen sulfide level changes by imaging endogenous hydrogen sulfide signal in RAW264.7 cells incubated with L1 and L2. Expanding the use of L1 to complex and heterogeneous biological settings, we successfully visualized hydrogen sulfide detection in the yolk, brain and spinal cord of living zebrafish embryos, thereby providing a powerful approach for live imaging for investigating chemical signaling in complex multicellular systems.
Chen, Po-Cheng; Li, Yu-Chi; Ma, Jia-Yin; Huang, Jia-Yu; Chen, Chien-Fu; Chang, Huan-Tsung
2016-01-01
Polystyrene sulfonate (PSS), a strong polyelectrolyte, was used to prepare red photoluminescent PSS-penicillamine (PA) copper (Cu) nanoclusters (NC) aggregates, which displayed high selectivity and sensitivity to the detection of hydrogen sulfide (H2S). The size of the PSS-PA-Cu NC aggregates could be readily controlled from 5.5 μm to 173 nm using different concentrations of PSS, which enabled better dispersity and higher sensitivity towards H2S. PSS-PA-Cu NC aggregates provided rapid H2S detection by using the strong Cu-S interaction to quench NC photoluminescence as a sensing mechanism. As a result, a detection limit of 650 nM, which is lower than the maximum level permitted in drinking water by the World Health Organization, was achieved for the analysis of H2S in spring-water samples. Moreover, highly dispersed PSS-PA-Cu NC aggregates could be incorporated into a plate-format paper-based analytical device which enables ultra-low sample volumes (5 μL) and feature shorter analysis times (30 min) compared to conventional solution-based methods. The advantages of low reagent consumption, rapid result readout, limited equipment, and long-term storage make this platform sensitive and simple enough to use without specialized training in resource constrained settings. PMID:27113330
Lin, Wenwen; Stoumpos, Constantinos C; Kontsevoi, Oleg Y; Liu, Zhifu; He, Yihui; Das, Sanjib; Xu, Yadong; McCall, Kyle M; Wessels, Bruce W; Kanatzidis, Mercouri G
2018-02-07
Cu 2 I 2 Se 6 is a new wide-bandgap semiconductor with high stability and great potential toward hard radiation and photon detection. Cu 2 I 2 Se 6 crystallizes in the rhombohedral R3̅m space group with a density of d = 5.287 g·cm -3 and a wide bandgap E g of 1.95 eV. First-principles electronic band structure calculations at the density functional theory level indicate an indirect bandgap and a low electron effective mass m e * of 0.32. The congruently melting compound was grown in centimeter-size Cu 2 I 2 Se 6 single crystals using a vertical Bridgman method. A high electric resistivity of ∼10 12 Ω·cm is readily achieved, and detectors made of Cu 2 I 2 Se 6 single crystals demonstrate high photosensitivity to Ag Kα X-rays (22.4 keV) and show spectroscopic performance with energy resolutions under 241 Am α-particles (5.5 MeV) radiation. The electron mobility is measured by a time-of-flight technique to be ∼46 cm 2 ·V -1 ·s -1 . This value is comparable to that of one of the leading γ-ray detector materials, TlBr, and is a factor of 30 higher than mobility values obtained for amorphous Se for X-ray detection.
Chemical Components of Cells at the Microscopic Level.
ERIC Educational Resources Information Center
Freeman, H. E.
1985-01-01
Thin slices of potato can be used to demonstrate the presence of protein, carbohydrates, and nucleic acids at the cellular level. Procedures and materials are provided for these simple tests. Also indicates that the presence of fat can be readily seen by staining avocado with Sudan red or Sudan black. (Author/DH)
The NATO Alliance: US Conventional Force Level Options Toward it Based on US National Interests.
1981-09-01
24 percent level for 1979, it has recently slowed down due to price controls and the slower depreciation of the escudo . Real wage increases declined...one can readily establisb US current and past generosity, in fiscal terms, toward the Atlantic Alliance. In conclusion, the fifteen countries presently
Direct injection GC method for measuring light hydrocarbon emissions from cooling-tower water.
Lee, Max M; Logan, Tim D; Sun, Kefu; Hurley, N Spencer; Swatloski, Robert A; Gluck, Steve J
2003-12-15
A Direct Injection GC method for quantifying low levels of light hydrocarbons (C6 and below) in cooling water has been developed. It is intended to overcome the limitations of the currently available technology. The principle of this method is to use a stripper column in a GC to strip waterfrom the hydrocarbons prior to entering the separation column. No sample preparation is required since the water sample is introduced directly into the GC. Method validation indicates that the Direct Injection GC method offers approximately 15 min analysis time with excellent precision and recovery. The calibration studies with ethylene and propylene show that both liquid and gas standards are suitable for routine calibration and calibration verification. The sampling method using zero headspace traditional VOA (Volatile Organic Analysis) vials and a sample chiller has also been validated. It is apparent that the sampling method is sufficient to minimize the potential for losses of light hydrocarbons, and samples can be held at 4 degrees C for up to 7 days with more than 93% recovery. The Direct Injection GC method also offers <1 ppb (w/v) level method detection limits for ethylene, propylene, and benzene. It is superior to the existing El Paso stripper method. In addition to lower detection limits for ethylene and propylene, the Direct Injection GC method quantifies individual light hydrocarbons in cooling water, provides better recoveries, and requires less maintenance and setup costs. Since the instrumentation and supplies are readily available, this technique could easily be established as a standard or alternative method for routine emission monitoring and leak detection of light hydrocarbons in cooling-tower water.
Vangnai, Alisa S; Kataoka, Naoya; Soonglerdsongpha, Suwat; Kalambaheti, Chatvalee; Tajima, Takahisa; Kato, Junichi
2012-12-01
Aniline and chlorinated anilines (CAs) are classified as priority pollutants; therefore, an effective method for detection and monitoring is required. In this study, a green-fluorescence protein-based bioreporter for the detection of aniline and CAs was constructed in Escherichia coli DH5α, characterized and tested with soil and wastewater. The sensing capability relied on the regulatory control between a two-component regulatory protein, TodS/TodT, and the P( todX ) promoter of Pseudomonas putida T-57 (PpT57), since the gene expression of todS, todT, and todC2 are positively induced with 4-chloroaniline. The bioreporter system (DH5α/pPXGFP-pTODST) is markedly unique with the two co-existing plasmids. The inducibility of the fluorescence response was culture-medium- and time-dependent. Cells grown in M9G medium exhibited a low background fluorescence level and were readily induced by 4CA after 3-h exposure, reaching the maximum induction level at 9 h. When tested with benzene, toluene, ethyl-benzene and xylene, aniline and CAs, the response data were best fit by a sigmoidal dose-response relationship, from which the K(½) value was determined for the positive effectors. 3CA and 4CA were relatively powerful inducers, while some poly-chlorinated anilines could also induce green fluorescence protein expression. The results indicated a broader recognition range of PpT57'sTodST than previously reported for P. putida. The test results with environmental samples were reliable, indicating the potential application of this bioreporter in the ecotoxicology assessment and bioremediation of areas contaminated with aniline- and/or CAs.
Identification of circulating microRNAs in HNF1A-MODY carriers.
Bonner, C; Nyhan, K C; Bacon, S; Kyithar, M P; Schmid, J; Concannon, C G; Bray, I M; Stallings, R L; Prehn, J H M; Byrne, M M
2013-08-01
HNF1A-MODY is a monogenic form of diabetes caused by mutations in the HNF1A gene. Here we identify, for the first time, HNF1A-MODY-associated microRNAs (miRNAs) that can be detected in the serum of HNF1A-MODY carriers. An miRNA array was carried out in rat INS-1 insulinoma cells inducibly expressing the common human Pro291fsinsC-HNF1A frame shift mutation. Differentially expressed miRNAs were validated by quantitative real-time PCR. Expression of miRNAs in the serum of HNF1A-MODY carriers (n = 31), MODY-negative family members (n = 10) and individuals with type 2 diabetes mellitus (n = 17) was quantified by absolute real-time PCR analysis. Inducible expression of Pro291fsinsC-HNF1A in INS-1 cells caused a significant upregulation of three miRNAs (miR-103, miR-224, miR-292-3p). The differential expression of two miRNAs (miR-103 and miR-224) was validated in vitro. Strongly elevated levels of miR-103 and miR-224 could be detected in the serum of HNF1A-MODY carriers compared with MODY-negative family controls. Serum levels of miR-103 distinguished HNF1A-MODY carriers from HbA1c-matched individuals with type 2 diabetes mellitus. Our study demonstrates that the pathophysiology of HNF1A-MODY is associated with the overexpression of miR-103 and miR-224. Furthermore, our study demonstrates that these miRNAs can be readily detected in the serum of HNF1A-MODY carriers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bojechko, C.; Ford, E. C., E-mail: eford@uw.edu
Purpose: To quantify the ability of electronic portal imaging device (EPID) dosimetry used during treatment (in vivo) in detecting variations that can occur in the course of patient treatment. Methods: Images of transmitted radiation from in vivo EPID measurements were converted to a 2D planar dose at isocenter and compared to the treatment planning dose using a prototype software system. Using the treatment planning system (TPS), four different types of variability were modeled: overall dose scaling, shifting the positions of the multileaf collimator (MLC) leaves, shifting of the patient position, and changes in the patient body contour. The gamma passmore » rate was calculated for the modified and unmodified plans and used to construct a receiver operator characteristic (ROC) curve to assess the detectability of the different parameter variations. The detectability is given by the area under the ROC curve (AUC). The TPS was also used to calculate the impact of the variations on the target dose–volume histogram. Results: Nine intensity modulation radiation therapy plans were measured for four different anatomical sites consisting of 70 separate fields. Results show that in vivo EPID dosimetry was most sensitive to variations in the machine output, AUC = 0.70 − 0.94, changes in patient body habitus, AUC = 0.67 − 0.88, and systematic shifts in the MLC bank positions, AUC = 0.59 − 0.82. These deviations are expected to have a relatively small clinical impact [planning target volume (PTV) D{sub 99} change <7%]. Larger variations have even higher detectability. Displacements in the patient’s position and random variations in MLC leaf positions were not readily detectable, AUC < 0.64. The D{sub 99} of the PTV changed by up to 57% for the patient position shifts considered here. Conclusions: In vivo EPID dosimetry is able to detect relatively small variations in overall dose, systematic shifts of the MLC’s, and changes in the patient habitus. Shifts in the patient’s position which can introduce large changes in the target dose coverage were not readily detected.« less
Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
Fowler, Anna; Mahamdallie, Shazia; Ruark, Elise; Seal, Sheila; Ramsay, Emma; Clarke, Matthew; Uddin, Imran; Wylie, Harriet; Strydom, Ann; Lunter, Gerton; Rahman, Nazneen
2016-11-25
Background: Targeted next generation sequencing (NGS) panels are increasingly being used in clinical genomics to increase capacity, throughput and affordability of gene testing. Identifying whole exon deletions or duplications (termed exon copy number variants, 'exon CNVs') in exon-targeted NGS panels has proved challenging, particularly for single exon CNVs. Methods: We developed a tool for the Detection of Exon Copy Number variants (DECoN), which is optimised for analysis of exon-targeted NGS panels in the clinical setting. We evaluated DECoN performance using 96 samples with independently validated exon CNV data. We performed simulations to evaluate DECoN detection performance of single exon CNVs and to evaluate performance using different coverage levels and sample numbers. Finally, we implemented DECoN in a clinical laboratory that tests BRCA1 and BRCA2 with the TruSight Cancer Panel (TSCP). We used DECoN to analyse 1,919 samples, validating exon CNV detections by multiplex ligation-dependent probe amplification (MLPA). Results: In the evaluation set, DECoN achieved 100% sensitivity and 99% specificity for BRCA exon CNVs, including identification of 8 single exon CNVs. DECoN also identified 14/15 exon CNVs in 8 other genes. Simulations of all possible BRCA single exon CNVs gave a mean sensitivity of 98% for deletions and 95% for duplications. DECoN performance remained excellent with different levels of coverage and sample numbers; sensitivity and specificity was >98% with the typical NGS run parameters. In the clinical pipeline, DECoN automatically analyses pools of 48 samples at a time, taking 24 minutes per pool, on average. DECoN detected 24 BRCA exon CNVs, of which 23 were confirmed by MLPA, giving a false discovery rate of 4%. Specificity was 99.7%. Conclusions: DECoN is a fast, accurate, exon CNV detection tool readily implementable in research and clinical NGS pipelines. It has high sensitivity and specificity and acceptable false discovery rate. DECoN is freely available at www.icr.ac.uk/decon.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, A.N.; Benson, S.C.
1997-07-08
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, A.M.; Benson, S.C.
1998-06-16
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.
Ultrasonic defect detection in wooden pallet parts for quality sorting
Daniel L. Schmoldt; Robert J. Ross; Robert M. Nelson
1996-01-01
Millions of wooden pallets are discarded annually due to damage or because their low cost makes them readily disposable. Higher quality wooden pallets, however, can be built from high quality deckboards and stringers, and have a much longer life cycle and a lower cost per trip. The long-term goal of this project is to develop an automated pallet part inspection system...
Ultrasonic Defect Detection in Wooden Pallet Parts for Quality Sorting
Daniel L. Schmoldt; Robert M. Nelson; Robert J. Ross
1996-01-01
Millions of wooden pallets are discarded annually due to damage or because their low cost makes them readily disposable. Higher quality wooden pallets, however, can be built from high quality deckboards and stringers, and have a much longer life cycle and a lower cost per trip. The long-term goal of this project is to develop an automated pallet part inspection system...
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, A.N.; Benson, S.C.
1995-03-28
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figures.
Recent advances in superconducting nanowire single photon detectors for single-photon imaging
NASA Astrophysics Data System (ADS)
Verma, V. B.; Allman, M. S.; Stevens, M.; Gerrits, T.; Horansky, R. D.; Lita, A. E.; Marsili, F.; Beyer, A.; Shaw, M. D.; Stern, J. A.; Mirin, R. P.; Nam, S. W.
2016-05-01
We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is employed to reduce the number of readout lines to 16. The cryogenic, optical, and electronic packaging to read out the array, as well as characterization measurements are discussed.
Submicrometer Metallic Barcodes
NASA Astrophysics Data System (ADS)
Nicewarner-Peña, Sheila R.; Freeman, R. Griffith; Reiss, Brian D.; He, Lin; Peña, David J.; Walton, Ian D.; Cromer, Remy; Keating, Christine D.; Natan, Michael J.
2001-10-01
We synthesized multimetal microrods intrinsically encoded with submicrometer stripes. Complex striping patterns are readily prepared by sequential electrochemical deposition of metal ions into templates with uniformly sized pores. The differential reflectivity of adjacent stripes enables identification of the striping patterns by conventional light microscopy. This readout mechanism does not interfere with the use of fluorescence for detection of analytes bound to particles by affinity capture, as demonstrated by DNA and protein bioassays.
2012-07-12
readily transferable to diverse real-time PCR instrumentation. These assays are used regularly for vector surveillance and are the primary...instrumentation ( FilmArray ) is under assessment. Assay oligonucleotide sequences and formulations are available for use in future joint projects...Plasmodium real-time PCR detection capability has been challenging. During 2006, the Division of Entomology, WRAIR designed and developed a
SPACE PHYSICS: Developing resources for astrophysics at A-level: the TRUMP Astrophysics project
NASA Astrophysics Data System (ADS)
Swinbank, Elizabeth
1997-01-01
After outlining the astrophysical options now available in A-level physics syllabuses, this paper notes some of the particular challenges facing A-level teachers and students who chose these options and describes a project designed to support them. The paper highlights some key features of the project that could readily be incorporated into other areas of physics curriculum development.
Changes in fat-soluble vitamin levels after gastrectomy for gastric cancer.
Rino, Yasushi; Oshima, Takashi; Yoshikawa, Takaki
2017-02-01
Several authors have reported the relationship between gastric cancer risk and vitamins. However, there are few reports on fat-soluble vitamins after gastrectomy for gastric cancer. Fat malabsorption and suppression of food intake after gastrectomy for gastric cancer have been previously documented. Because of fat malabsorption and suppression of food intake, a potential deficiency in fat-soluble vitamins, such as vitamins A, D, E, and K, has been readily suggested. In about 20 % of patients, the serum vitamin E levels were decreased. Indeed, vitamin E deficiency is a common complication after gastrectomy. Continuous vitamin E deficiency could develop from neurological symptoms, i.e., peripheral neuropathy, limb or truncal ataxia. The total cholesterol level is associated with the vitamin E levels. However, the serum vitamin A levels were decreased in only 1.8 % of patients. In total gastrectomy cases, the serum vitamin A level may readily decrease. In contrast, 1,25(OH) 2 vitamin D deficiency, which is the most active vitamin D metabolite, is rare. Additionally, vitamin K deficiency after gastrectomy has not been reported thus far. Evidence that serum fat-soluble vitamin levels may decrease after gastrectomy for gastric cancer has not been established yet. Future research must explore fat-soluble vitamin deficiency after gastrectomy.
Accurate Differentiation of Carotenoid Pigments Using Flight Representative Raman Spectrometers.
Malherbe, Cedric; Hutchinson, Ian B; McHugh, Melissa; Ingley, Richard; Jehlička, Jan; Edwards, Howell G M
2017-04-01
Raman spectrometers will be utilized on two Mars rover missions, ExoMars and Mars 2020, in the near future, to search for evidence of life and habitable geological niches on Mars. Carotenoid pigments are recognized target biomarkers, and as they are highly active in Raman spectroscopy, they can be readily used to characterize the capabilities of space representative instrumentation. As part of the preparatory work being performed for the ExoMars mission, a gypsum crust colonized by microorganisms was interrogated with commercial portable Raman instruments and a flight representative Raman laser spectrometer. Four separate layers, each exhibiting different coloration resulting from specific halophilic microorganism activities within the gypsum crust, were studied by using two excitation wavelengths: 532 and 785 nm. Raman or fluorescence data were readily obtained during the present study. Gypsum, the main constituent of the crust, was detected with both excitation wavelengths, while the resonance Raman signal associated with carotenoid pigments was only detected with a 532 nm excitation wavelength. The fluorescence originating from bacteriochlorophyll a was found to overwhelm the Raman signal for the layer colonized by sulfur bacteria when interrogated with a 785 nm excitation wavelength. Finally, it was demonstrated that portable instruments and the prototype were capable of detecting a statistically significant difference in band positions of carotenoid signals between the sample layers. Key Words: Gypsum-Raman spectrometers-Carotenoids-ExoMars-Mars exploration-Band position shift. Astrobiology 17, 351-362.
Developing A New Sampling and Analysis Method for Hydrazine and Monomethyl Hydrazine
NASA Technical Reports Server (NTRS)
Allen, John R.
2002-01-01
Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCl), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.
A rhodol-based fluorescent chemosensor for hydrazine and its application in live cell bioimaging
NASA Astrophysics Data System (ADS)
Tiensomjitr, Khomsan; Noorat, Rattha; Wechakorn, Kanokorn; Prabpai, Samran; Suksen, Kanoknetr; Kanjanasirirat, Phongthon; Pewkliang, Yongyut; Borwornpinyo, Suparerk; Kongsaeree, Palangpon
2017-10-01
A rhodol cinnamate fluorescent chemosensor (RC) has been developed for selective detection of hydrazine (N2H4). In aqueous medium, the rhodol-based probe exhibited high selectivity for hydrazine among other molecules. The addition of hydrazine triggered a fluorescence emission with 48-fold enhancement based on hydrazinolysis and a subsequent ring-opening process. The chemical probe also displayed a selective colorimetric response toward N2H4 from colorless solution to pink, readily observed by the naked eye. The detection limit of RC for hydrazine was calculated to be 300 nM (9.6 ppb). RC is membrane permeable and was successfully demonstrated to detect hydrazine in live HepG2 cells by confocal fluorescence microscopy.
Wearable Performance Devices in Sports Medicine
Li, Ryan T.; Kling, Scott R.; Salata, Michael J.; Cupp, Sean A.; Sheehan, Joseph; Voos, James E.
2016-01-01
Context: Wearable performance devices and sensors are becoming more readily available to the general population and athletic teams. Advances in technology have allowed individual endurance athletes, sports teams, and physicians to monitor functional movements, workloads, and biometric markers to maximize performance and minimize injury. Movement sensors include pedometers, accelerometers/gyroscopes, and global positioning satellite (GPS) devices. Physiologic sensors include heart rate monitors, sleep monitors, temperature sensors, and integrated sensors. The purpose of this review is to familiarize health care professionals and team physicians with the various available types of wearable sensors, discuss their current utilization, and present future applications in sports medicine. Evidence Acquisition: Data were obtained from peer-reviewed literature through a search of the PubMed database. Included studies searched development, outcomes, and validation of wearable performance devices such as GPS, accelerometers, and physiologic monitors in sports. Study Design: Clinical review. Level of Evidence: Level 4. Results: Wearable sensors provide a method of monitoring real-time physiologic and movement parameters during training and competitive sports. These parameters can be used to detect position-specific patterns in movement, design more efficient sports-specific training programs for performance optimization, and screen for potential causes of injury. More recent advances in movement sensors have improved accuracy in detecting high-acceleration movements during competitive sports. Conclusion: Wearable devices are valuable instruments for the improvement of sports performance. Evidence for use of these devices in professional sports is still limited. Future developments are needed to establish training protocols using data from wearable devices. PMID:26733594
A method to identify and characterize Z-DNA binding proteins using a linear oligodeoxynucleotide
NASA Technical Reports Server (NTRS)
Herbert, A. G.; Rich, A.
1993-01-01
An oligodeoxynucleotide that readily flips to the Z-DNA conformation in 10mM MgCl2 was produced by using Klenow enzyme to incorporate 5-bromodeoxycytosine and deoxyguanosine into a (dC-dG)22 template. During synthesis the oligomer can be labeled with 32P to high specific activity. The labeled oligodeoxynucleotide can be used in bandshift experiment to detect proteins that bind Z-DNA. This allows the binding specificity of such proteins to be determined with high reliability using unlabeled linear and supercoiled DNA competitors. In addition, because the radioactive oligodeoxynucleotide contains bromine atoms, DNA-protein complexes can be readily crosslinked using UV light. This allows an estimate to be made of the molecular weight of the proteins that bind to the radioactive probe. Both techniques are demonstrated using a goat polyclonal anti-Z-DNA antiserum.
Readily releasable pool of synaptic vesicles measured at single synaptic contacts.
Trigo, Federico F; Sakaba, Takeshi; Ogden, David; Marty, Alain
2012-10-30
To distinguish between different models of vesicular release in brain synapses, it is necessary to know the number of vesicles of transmitter that can be released immediately at individual synapses by a high-calcium stimulus, the readily releasable pool (RRP). We used direct stimulation by calcium uncaging at identified, single-site inhibitory synapses to investigate the statistics of vesicular release and the size of the RRP. Vesicular release, detected as quantal responses in the postsynaptic neuron, showed an unexpected stochastic variation in the number of quanta from stimulus to stimulus at high intracellular calcium, with a mean of 1.9 per stimulus and a maximum of three or four. The results provide direct measurement of the RRP at single synaptic sites. They are consistent with models in which release proceeds from a small number of vesicle docking sites with an average occupancy around 0.7.
Steinheimer, T.R.; Brooks, M.G.
1984-01-01
A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.
Yiee, Jenny H.; Tasian, Gregory E.; Copp, Hillary L.
2011-01-01
Objectives Hydronephrosis is the most common abnormality found on prenatal ultrasound. The utility of prophylactic antibiotics in the postnatal management of this condition is controversial. No study has assessed practice patterns of general pediatricians in the management of prenatally-detected hydronephrosis. Methods An 18 question survey was sent to a random cross-sectional national sample of pediatricians from the American Medical Association Masterfile. Participants answered questions regarding practice location and type, practice experience, frequency of cases seen, familiarity with the literature, use of antibiotics, work-up of hydronephrosis, and specialist referral. Multivariate logistic regression identified factors associated with prescribing antibiotics. Results 244 of 461 (53%) subjects responded. 56% routinely prescribe antibiotics for prenatally-detected hydronephrosis. 57% perform postnatal work-up themselves. Of these, 98% routinely order ultrasounds while ~40% routinely order voiding cystourethrograms. 94% have specialists readily available, but only 41% always refer to a specialist. On multivariate logistic regression, those who believe prophylactic antibiotics to be beneficial are significantly more likely to prescribe antibiotics compared with those who have not read the literature (OR 6.1, 95%CI 2–15). Those without specialist consultation readily available have an increased odds of starting prophylactic antibiotics compared with those who have consultation available (OR 7.2, 95%CI 1.3–39). Conclusion Most pediatricians initiate postnatal management of prenatally-detected hydronephrosis, therefore pediatricians truly are gatekeepers to children with this condition. Knowledge of practice patterns is crucial for the dissemination of evidence-based information to the appropriate providers and enables us to learn more about the utility of antibiotic prophylaxis in future studies. PMID:21696811
Kurashige, Tomomi; Shimamura, Mika; Nagayama, Yuji
2016-06-01
The biological effect of ionizing radiation (IR) on genomic DNA is thought to be either direct or indirect; the latter is mediated by IR induction of free radicals and reactive oxygen species (ROS). This study was designed to evaluate the effect of N-acetyl-L-cysteine (NAC), a well-known ROS-scavenging antioxidant, on IR induction of genotoxicity, cytotoxicity and ROS production in mammalian cells, and aimed to clarify the conflicting data in previous publications. Although we clearly demonstrate the beneficial effect of NAC on IR-induced genotoxicity and cytotoxicity (determined using the micronucleus assay and cell viability/clonogenic assays), the data on NAC's effect on DNA double-strand break (DSB) formation were inconsistent in different assays. Specifically, mitigation of IR-induced DSBs by NAC was readily detected by the neutral comet assay, but not by the γH2AX or 53BP1 focus assays. NAC is a glutathione precursor and exerts its effect after conversion to glutathione, and presumably it has its own biological activity. Assuming that the focus assay reflects the biological responses to DSBs (detection and repair), while the comet assay reflects the physical status of genomic DNA, our results indicate that the comet assay could readily detect the antioxidant effect of NAC on DSB formation. However, NAC's biological effect might affect the detection of DSB repair by the focus assays. Our data illustrate that multiple parameters should be carefully used to analyze DNA damage when studying potential candidates for radioprotective compounds. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Damage of composite structures: Detection technique, dynamic response and residual strength
NASA Astrophysics Data System (ADS)
Lestari, Wahyu
2001-10-01
Reliable and accurate health monitoring techniques can prevent catastrophic failures of structures. Conventional damage detection methods are based on visual or localized experimental methods and very often require prior information concerning the vicinity of the damage or defect. The structure must also be readily accessible for inspections. The techniques are also labor intensive. In comparison to these methods, health-monitoring techniques that are based on the structural dynamic response offers unique information on failure of structures. However, systematic relations between the experimental data and the defect are not available and frequently, the number of vibration modes needed for an accurate identification of defects is much higher than the number of modes that can be readily identified in the experiment. These motivated us to develop an experimental data based detection method with systematic relationships between the experimentally identified information and the analytical or mathematical model representing the defective structures. The developed technique use changes in vibrational curvature modes and natural frequencies. To avoid misinterpretation of the identified information, we also need to understand the effects of defects on the structural dynamic response prior to developing health-monitoring techniques. In this thesis work we focus on two type of defects in composite structures, namely delamination and edge notch like defect. Effects of nonlinearity due to the presence of defect and due to the axial stretching are studied for beams with delamination. Once defects are detected in a structure, next concern is determining the effects of the defects on the strength of the structure and its residual stiffness under dynamic loading. In this thesis, energy release rate due to dynamic loading in a delaminated structure is studied, which will be a foundation toward determining the residual strength of the structure.
Barnette, Anna L; Bradley, Laura C; Veres, Brandon D; Schreiner, Edward P; Park, Yong Bum; Park, Junyeong; Park, Sunkyu; Kim, Seong H
2011-07-11
The selective detection of crystalline cellulose in biomass was demonstrated with sum-frequency-generation (SFG) vibration spectroscopy. SFG is a second-order nonlinear optical response from a system where the optical centrosymmetry is broken. In secondary plant cell walls that contain mostly cellulose, hemicellulose, and lignin with varying concentrations, only certain vibration modes in the crystalline cellulose structure can meet the noninversion symmetry requirements. Thus, SFG can be used to detect and analyze crystalline cellulose selectively in lignocellulosic biomass without extraction of noncellulosic species from biomass or deconvolution of amorphous spectra. The selective detection of crystalline cellulose in lignocellulosic biomass is not readily achievable with other techniques such as XRD, solid-state NMR, IR, and Raman analyses. Therefore, the SFG analysis presents a unique opportunity to reveal the cellulose crystalline structure in lignocellulosic biomass.
Cao, Jing; Feng, Chao; Liu, Yan; Wang, Shouyu; Liu, Fei
2014-07-15
Since many diseases are caused by pathogenic bacterial infections, accurate and rapid detection of pathogenic bacteria is in urgent need to timely apply appropriate treatments and to reduce economic costs. To end this, we designed molecular beacon-Au nanoparticle hybrid nanoprobes to improve the bacterial detection efficiency and sensitivity. Here, we show that the designed molecular beacon modified Au nanoparticles could specifically recognize synthetic DNAs targets and can readily detect targets in clinical samples. Moreover, the hybrid nanoprobes can recognize Escherichia coli within an hour at a concentration of 10(2) cfu/ml, which is 1000-folds sensitive than using molecular beacon directly. Our results show that the molecular beacon-Au nanoparticle hybrid nanoprobes have great potential in medical and biological applications. Copyright © 2014 Elsevier B.V. All rights reserved.
McGrory, Ellen R; Brown, Colin; Bargary, Norma; Williams, Natalya Hunter; Mannix, Anthony; Zhang, Chaosheng; Henry, Tiernan; Daly, Eve; Nicholas, Sarah; Petrunic, Barbara M; Lee, Monica; Morrison, Liam
2017-02-01
The presence of arsenic in groundwater has become a global concern due to the health risks from drinking water with elevated concentrations. The Water Framework Directive (WFD) of the European Union calls for drinking water risk assessment for member states. The present study amalgamates readily available national and sub-national scale datasets on arsenic in groundwater in the Republic of Ireland. However, due to the presence of high levels of left censoring (i.e. arsenic values below an analytical detection limit) and changes in detection limits over time, the application of conventional statistical methods would inhibit the generation of meaningful results. In order to handle these issues several arsenic databases were integrated and the data modelled using statistical methods appropriate for non-detect data. In addition, geostatistical methods were used to assess principal risk components of elevated arsenic related to lithology, aquifer type and groundwater vulnerability. Geographic statistical methods were used to overcome some of the geographical limitations of the Irish Environmental Protection Agency (EPA) sample database. Nearest-neighbour inverse distance weighting (IDW) and local indicator of spatial association (LISA) methods were used to estimate risk in non-sampled areas. Significant differences were also noted between different aquifer lithologies, indicating that Rhyolite, Sandstone and Shale (Greywackes), and Impure Limestone potentially presented a greater risk of elevated arsenic in groundwaters. Significant differences also occurred among aquifer types with poorly productive aquifers, locally important fractured bedrock aquifers and regionally important fissured bedrock aquifers presenting the highest potential risk of elevated arsenic. No significant differences were detected among different groundwater vulnerability groups as defined by the Geological Survey of Ireland. This research will assist management and future policy directions of groundwater resources at EU level and guide future research focused on understanding arsenic mobilisation processes to facilitate in guiding future development, testing and treatment requirements of groundwater resources. Copyright © 2016 Elsevier B.V. All rights reserved.
40 CFR 211.204-4 - Supporting information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... level as measured at the ear is 92 dBA. 2. The NRR is (value on label) decibels (dB). 3. The level of... must be affixed to the bulk container or dispenser in the same manner as the label, and in a readily... entering a person's ear, when hearing protector is worn as directed, is closely approximated by the...
A Risk Assessment Methodology and Excel Tool for Acquisition Programs
2013-01-01
Importance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11...readily available to an assessor at the OSD level. Questions that measure these standards are assigned (1) an importance (i.e., mag- nitude of the negative...i.e., the level to which it has been ensured that the question-related standard has been met). The sum product of the importance and completeness
Characterization of Model-Based Reasoning Strategies for Use in IVHM Architectures
NASA Technical Reports Server (NTRS)
Poll, Scott; Iverson, David; Patterson-Hine, Ann
2003-01-01
Open architectures are gaining popularity for Integrated Vehicle Health Management (IVHM) applications due to the diversity of subsystem health monitoring strategies in use and the need to integrate a variety of techniques at the system health management level. The basic concept of an open architecture suggests that whatever monitoring or reasoning strategy a subsystem wishes to deploy, the system architecture will support the needs of that subsystem and will be capable of transmitting subsystem health status across subsystem boundaries and up to the system level for system-wide fault identification and diagnosis. There is a need to understand the capabilities of various reasoning engines and how they, coupled with intelligent monitoring techniques, can support fault detection and system level fault management. Researchers in IVHM at NASA Ames Research Center are supporting the development of an IVHM system for liquefying-fuel hybrid rockets. In the initial stage of this project, a few readily available reasoning engines were studied to assess candidate technologies for application in next generation launch systems. Three tools representing the spectrum of model-based reasoning approaches, from a quantitative simulation based approach to a graph-based fault propagation technique, were applied to model the behavior of the Hybrid Combustion Facility testbed at Ames. This paper summarizes the characterization of the modeling process for each of the techniques.
Winkelmann, Inger; Campos, Paula F.; Strugnell, Jan; Cherel, Yves; Smith, Peter J.; Kubodera, Tsunemi; Allcock, Louise; Kampmann, Marie-Louise; Schroeder, Hannes; Guerra, Angel; Norman, Mark; Finn, Julian; Ingrao, Debra; Clarke, Malcolm; Gilbert, M. Thomas P.
2013-01-01
Despite its charismatic appeal to both scientists and the general public, remarkably little is known about the giant squid Architeuthis, one of the largest of the invertebrates. Although specimens of Architeuthis are becoming more readily available owing to the advancement of deep-sea fishing techniques, considerable controversy exists with regard to topics as varied as their taxonomy, biology and even behaviour. In this study, we have characterized the mitochondrial genome (mitogenome) diversity of 43 Architeuthis samples collected from across the range of the species, in order to use genetic information to provide new and otherwise difficult to obtain insights into the life of this animal. The results show no detectable phylogenetic structure at the mitochondrial level and, furthermore, that the level of nucleotide diversity is exceptionally low. These observations are consistent with the hypotheses that there is only one global species of giant squid, Architeuthis dux (Steenstrup, 1857), and that it is highly vagile, possibly dispersing through both a drifting paralarval stage and migration of larger individuals. Demographic history analyses of the genetic data suggest that there has been a recent population expansion or selective sweep, which may explain the low level of genetic diversity. PMID:23516246
Use of Readily Accessible Inflammatory Markers to Predict Diabetic Kidney Disease.
Winter, Lauren; Wong, Lydia A; Jerums, George; Seah, Jas-Mine; Clarke, Michele; Tan, Sih Min; Coughlan, Melinda T; MacIsaac, Richard J; Ekinci, Elif I
2018-01-01
Diabetic kidney disease is a common complication of type 1 and type 2 diabetes and is the primary cause of end-stage renal disease in developed countries. Early detection of diabetic kidney disease will facilitate early intervention aimed at reducing the rate of progression to end-stage renal disease. Diabetic kidney disease has been traditionally classified based on the presence of albuminuria. More recently estimated glomerular filtration rate has also been incorporated into the staging of diabetic kidney disease. While albuminuric diabetic kidney disease is well described, the phenotype of non-albuminuric diabetic kidney disease is now widely accepted. An association between markers of inflammation and diabetic kidney disease has previously been demonstrated. Effector molecules of the innate immune system including C-reactive protein, interleukin-6, and tumor necrosis factor-α are increased in patients with diabetic kidney disease. Furthermore, renal infiltration of neutrophils, macrophages, and lymphocytes are observed in renal biopsies of patients with diabetic kidney disease. Similarly high serum neutrophil and low serum lymphocyte counts have been shown to be associated with diabetic kidney disease. The neutrophil-lymphocyte ratio is considered a robust measure of systemic inflammation and is associated with the presence of inflammatory conditions including the metabolic syndrome and insulin resistance. Cross-sectional studies have demonstrated a link between high levels of the above inflammatory biomarkers and diabetic kidney disease. Further longitudinal studies will be required to determine if these readily available inflammatory biomarkers can accurately predict the presence and prognosis of diabetic kidney disease, above and beyond albuminuria, and estimated glomerular filtration rate.
Reinforcement learning with Marr.
Niv, Yael; Langdon, Angela
2016-10-01
To many, the poster child for David Marr's famous three levels of scientific inquiry is reinforcement learning-a computational theory of reward optimization, which readily prescribes algorithmic solutions that evidence striking resemblance to signals found in the brain, suggesting a straightforward neural implementation. Here we review questions that remain open at each level of analysis, concluding that the path forward to their resolution calls for inspiration across levels, rather than a focus on mutual constraints.
Garud, Nandita R; Rosenberg, Noah A
2015-06-01
Soft selective sweeps represent an important form of adaptation in which multiple haplotypes bearing adaptive alleles rise to high frequency. Most statistical methods for detecting selective sweeps from genetic polymorphism data, however, have focused on identifying hard selective sweeps in which a favored allele appears on a single haplotypic background; these methods might be underpowered to detect soft sweeps. Among exceptions is the set of haplotype homozygosity statistics introduced for the detection of soft sweeps by Garud et al. (2015). These statistics, examining frequencies of multiple haplotypes in relation to each other, include H12, a statistic designed to identify both hard and soft selective sweeps, and H2/H1, a statistic that conditional on high H12 values seeks to distinguish between hard and soft sweeps. A challenge in the use of H2/H1 is that its range depends on the associated value of H12, so that equal H2/H1 values might provide different levels of support for a soft sweep model at different values of H12. Here, we enhance the H12 and H2/H1 haplotype homozygosity statistics for selective sweep detection by deriving the upper bound on H2/H1 as a function of H12, thereby generating a statistic that normalizes H2/H1 to lie between 0 and 1. Through a reanalysis of resequencing data from inbred lines of Drosophila, we show that the enhanced statistic both strengthens interpretations obtained with the unnormalized statistic and leads to empirical insights that are less readily apparent without the normalization. Copyright © 2015 Elsevier Inc. All rights reserved.
Zheng, Fangyuan; Zeng, Fang; Yu, Changmin; Hou, Xianfeng; Wu, Shuizhu
2013-01-14
Owing to the considerable significance of fluoride anions for health and environmental issues, it is of great importance to develop methods that can rapidly, sensitively and selectively detect the fluoride anion in aqueous media and biological samples. Herein, we demonstrate a robust fluorescent turn-on sensor for detecting the fluoride ion in a totally aqueous solution. In this study, a biocompatible hydrophilic polymer poly(ethylene glycol) (PEG) is incorporated into the sensing system to ensure water solubility and to enhance biocompatibility. tert-Butyldiphenylsilyl (TBDPS) groups were then covalently introduced onto the fluorescein moiety, which effectively quenched the fluorescence of the sensor. Upon addition of fluoride ion, the selective fluoride-mediated cleavage of the Si-O bond leads to the recovery of the fluorescein moiety, resulting in a dramatic increase in fluorescence intensity under visible light excitation. The sensor is responsive and highly selective for the fluoride anion over other common anions; it also exhibits a very low detection limit of 19 ppb. In addition, this sensor is operative in some real samples such as running water, urine, and serum and can accurately detect fluoride ions in these samples. The cytotoxicity of the sensor was determined to be Grade I toxicity according to United States Pharmacopoeia and ISO 10993-5, suggesting the very low cytotoxicity of the sensor. Moreover, it was found that the senor could be readily internalized by both HeLa and L929 cells and the sensor could be utilized to track fluoride level changes inside the cells. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kepler Mission: A Search for Terrestrial Planets
NASA Technical Reports Server (NTRS)
Koch, D.; Borucki, W.; Jenkens, J.; Dunham, E.; DeVincenzi, Donald (Technical Monitor)
2001-01-01
The Kepler Mission is a search for terrestrial planets by monitoring a large ensemble of stars for the periodic transits of planets. The mission consists of a 95-cm aperture photometer with 105 square deg field of view that monitors 100,000 dwarf stars for four years. The mission is unique in its ability to detect Earth-size planets in the habitable zone of other stars in the extended solar neighborhood. An Earth-size transit of a solar-like star causes a change in brightness of about 100 ppm. Laboratory testing has demonstrated that a total system noise level of 20 ppm is readily achievable on the timescale of transits. Earth-like transits have been created and reliably measured in an end-to-end system test that has all known sources of noise including, spacecraft jitter. To detect Earth-size planets, the photometer must be spaceborne; this also eliminates the day-night and seasonal cycle interruptions of ground-based observing. The photometer will stare at a single field of stars for four years, with an option to continue for two more years. This allows for detection of four transits of planets in Mars-like orbits and detection of planets even smaller than Earth especially for short period orbits, since the signal to noise improves as the square root of the number of transits observed. In addition to detection of planets, Kepler data are also useful for understanding the activity cycles and rotation rates of the stars observed. For the 3,000 stars brighter than mv= 11.4 p-mode oscillations are measured. The mission has been selected as one of three candidates for NASA's next Discovery mission.
Hutchinson, Ian B.; Ingley, Richard; Marshall, Craig P.; Olcott Marshall, Alison; Edwards, Howell G.M.
2015-01-01
Abstract Knowledge and understanding of the martian environment has advanced greatly over the past two decades, beginning with NASA's return to the surface of Mars with the Pathfinder mission and its rover Sojourner in 1997 and continuing today with data being returned by the Curiosity rover. Reduced carbon, however, is yet to be detected on the martian surface, despite its abundance in meteorites originating from the planet. If carbon is detected on Mars, it could be a remnant of extinct life, although an abiotic source is much more likely. If the latter is the case, environmental carbonaceous material would still provide a source of carbon that could be utilized by microbial life for biochemical synthesis and could therefore act as a marker for potential habitats, indicating regions that should be investigated further. For this reason, the detection and characterization of reduced or organic carbon is a top priority for both the ESA/Roscosmos ExoMars rover, currently due for launch in 2018, and for NASA's Mars 2020 mission. Here, we present a Raman spectroscopic study of Archean chert Mars analog samples from the Pilbara Craton, Western Australia. Raman spectra were acquired with a flight-representative 532 nm instrument and a 785 nm instrument with similar operating parameters. Reduced carbon was successfully detected with both instruments; however, its Raman bands were detected more readily with 785 nm excitation, and the corresponding spectra exhibited superior signal-to-noise ratios and reduced background levels. Key Words: Raman spectroscopy—Archean—Organic matter—Planetary science—Mars. Astrobiology 15, 420–429. PMID:26060980
Acoustic Emission Sensing for Maritime Diesel Engine Performance and Health
2016-05-01
diesel internal combustion engine operating condition and health. A commercial-off- the-shelf AE monitoring system and a purpose-built data acquisition...subjected to external events such as a combustion event, fluid flow or the opening and closing of valves. This document reports on the monitoring and...conjunction with injection- combustion processes and valve events. AE from misfire as the result of a fuel injector malfunction was readily detectable
Determining Steady-state Tissue Residues for Invertebrates in Contaminated Sediment
2010-05-01
meter (Thermo Orion Electron Corp., Beverly, MA) equipped with a 95-12 ammonia sensitive electrode (Thermo Orion Electron Corp., Beverly, MA...analyzed using an Agilent 5890 gas chromatograph with electron capture detection. Metals were analyzed following methods 6010B and 6020 using a Perkin...readily into cyto- plasm , making it a strong candidate for biomagnification up the food chain (Mason et al. 1996; Wiener et al. 2003). The BSAF
USDA-ARS?s Scientific Manuscript database
Non-O157 Shiga toxin–producing Escherichia coli (STEC) strains are clinically important foodborne pathogens. Unlike E. coli O157:H7, these foodborne pathogens have no unique biochemical characteristics to readily distinguish them from other E. coli strains growing on plating media. In this study, a ...
Annual Progress Report FY-92. Volume 2
1992-01-01
OBJECTIVE To measure the effect of methotrexate on interleukin-l ( IL - 1 ) induced ICAN-l expression in cultured human fibroblasts and adenocarcinoma cells...SUMMARY SHEET TITLE: Effect of IL - 1 on Glucocorticoid Inhibition of Wound Healing KEYWORDS: IL - 1 , wound healing PRINCIPAL INVESTIGATOR: Schoenfeld, Phil CPT...PROGRESS Cultured cells were incubated with IL -l to stimulate ICAM-l expression. In general, the cells responded well. ICAM- 1 was readily detectable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenthall, L.; Fonseca, C.; Arzoumanian, A.
1979-03-01
Bile flow patterns were studied with serial /sup 99m/Tc-IDA images in 19 patients with cholecysto- and choledochointestinal anastomoses, gastroenteric bypasses, and combinations of the two. Complications such as anastomotic, afferent, and efferent loop obstruction and bile leakage were readily detected even in the presence of jaundice. This noninvasive technique warrants further investigation to determine its indications and weaknesses.
Zhang, Han; Wheeler, William; Hyland, Paula L; Yang, Yifan; Shi, Jianxin; Chatterjee, Nilanjan; Yu, Kai
2016-06-01
Meta-analysis of multiple genome-wide association studies (GWAS) has become an effective approach for detecting single nucleotide polymorphism (SNP) associations with complex traits. However, it is difficult to integrate the readily accessible SNP-level summary statistics from a meta-analysis into more powerful multi-marker testing procedures, which generally require individual-level genetic data. We developed a general procedure called Summary based Adaptive Rank Truncated Product (sARTP) for conducting gene and pathway meta-analysis that uses only SNP-level summary statistics in combination with genotype correlation estimated from a panel of individual-level genetic data. We demonstrated the validity and power advantage of sARTP through empirical and simulated data. We conducted a comprehensive pathway-based meta-analysis with sARTP on type 2 diabetes (T2D) by integrating SNP-level summary statistics from two large studies consisting of 19,809 T2D cases and 111,181 controls with European ancestry. Among 4,713 candidate pathways from which genes in neighborhoods of 170 GWAS established T2D loci were excluded, we detected 43 T2D globally significant pathways (with Bonferroni corrected p-values < 0.05), which included the insulin signaling pathway and T2D pathway defined by KEGG, as well as the pathways defined according to specific gene expression patterns on pancreatic adenocarcinoma, hepatocellular carcinoma, and bladder carcinoma. Using summary data from 8 eastern Asian T2D GWAS with 6,952 cases and 11,865 controls, we showed 7 out of the 43 pathways identified in European populations remained to be significant in eastern Asians at the false discovery rate of 0.1. We created an R package and a web-based tool for sARTP with the capability to analyze pathways with thousands of genes and tens of thousands of SNPs.
Zhang, Han; Wheeler, William; Hyland, Paula L.; Yang, Yifan; Shi, Jianxin; Chatterjee, Nilanjan; Yu, Kai
2016-01-01
Meta-analysis of multiple genome-wide association studies (GWAS) has become an effective approach for detecting single nucleotide polymorphism (SNP) associations with complex traits. However, it is difficult to integrate the readily accessible SNP-level summary statistics from a meta-analysis into more powerful multi-marker testing procedures, which generally require individual-level genetic data. We developed a general procedure called Summary based Adaptive Rank Truncated Product (sARTP) for conducting gene and pathway meta-analysis that uses only SNP-level summary statistics in combination with genotype correlation estimated from a panel of individual-level genetic data. We demonstrated the validity and power advantage of sARTP through empirical and simulated data. We conducted a comprehensive pathway-based meta-analysis with sARTP on type 2 diabetes (T2D) by integrating SNP-level summary statistics from two large studies consisting of 19,809 T2D cases and 111,181 controls with European ancestry. Among 4,713 candidate pathways from which genes in neighborhoods of 170 GWAS established T2D loci were excluded, we detected 43 T2D globally significant pathways (with Bonferroni corrected p-values < 0.05), which included the insulin signaling pathway and T2D pathway defined by KEGG, as well as the pathways defined according to specific gene expression patterns on pancreatic adenocarcinoma, hepatocellular carcinoma, and bladder carcinoma. Using summary data from 8 eastern Asian T2D GWAS with 6,952 cases and 11,865 controls, we showed 7 out of the 43 pathways identified in European populations remained to be significant in eastern Asians at the false discovery rate of 0.1. We created an R package and a web-based tool for sARTP with the capability to analyze pathways with thousands of genes and tens of thousands of SNPs. PMID:27362418
Design and application of cotranscriptional non-enzymatic RNA circuits and signal transducers
Bhadra, Sanchita; Ellington, Andrew D.
2014-01-01
Nucleic acid circuits are finding increasing real-life applications in diagnostics and synthetic biology. Although DNA has been the main operator in most nucleic acid circuits, transcriptionally produced RNA circuits could provide powerful alternatives for reagent production and their use in cells. Towards these goals, we have implemented a particular nucleic acid circuit, catalytic hairpin assembly, using RNA for both information storage and processing. Our results demonstrated that the design principles developed for DNA circuits could be readily translated to engineering RNA circuits that operated with similar kinetics and sensitivities of detection. Not only could purified RNA hairpins perform amplification reactions but RNA hairpins transcribed in vitro also mediated amplification, even without purification. Moreover, we could read the results of the non-enzymatic amplification reactions using a fluorescent RNA aptamer ‘Spinach’ that was engineered to undergo sequence-specific conformational changes. These advances were applied to the end-point and real-time detection of the isothermal strand displacement amplification reaction that produces single-stranded DNAs as part of its amplification cycle. We were also able to readily engineer gate structures with RNA similar to those that have previously formed the basis of DNA circuit computations. Taken together, these results validate an entirely new chemistry for the implementation of nucleic acid circuits. PMID:24493736
Cheng, Hao-Wen; Chen, Kuan-Chun; Raja, Joseph A J; Li, Jian-Xian; Yeh, Shyi-Dong
2013-04-15
NSscon (23 aa), a common epitope in the gene silencing suppressor NSs proteins of the members of the Watermelon silver mottle virus (WSMoV) serogroup, was previously identified. In this investigation, we expressed different green fluorescent protein (GFP)-fused deletions of NSscon in bacteria and reacted with NSscon monoclonal antibody (MAb). Our results indicated that the core 9 amino acids, "(109)KFTMHNQIF(117)", denoted as "nss", retain the reactivity of NSscon. In bacterial pET system, four different recombinant proteins labeled with nss, either at N- or C-extremes, were readily detectable without position effects, with sensitivity superior to that for the polyhistidine-tag. When the nss-tagged Zucchini yellow mosaic virus (ZYMV) helper component-protease (HC-Pro) and WSMoV nucleocapsid protein were transiently expressed by agroinfiltration in tobacco, they were readily detectable and the tag's possible efficacy for gene silencing suppression was not noticed. Co-immunoprecipitation of nss-tagged and non-tagged proteins expressed from bacteria confirmed the interaction of potyviral HC-Pro and coat protein. Thus, we conclude that this novel nss sequence is highly valuable for tagging recombinant proteins in both bacterial and plant expression systems. Copyright © 2013 Elsevier B.V. All rights reserved.
In situ simulated cardiac arrest exercises to detect system vulnerabilities.
Barbeito, Atilio; Bonifacio, Alberto; Holtschneider, Mary; Segall, Noa; Schroeder, Rebecca; Mark, Jonathan
2015-06-01
Sudden cardiac arrest is the leading cause of death in the United States. Despite new therapies, progress in this area has been slow, and outcomes remain poor even in the hospital setting, where providers, drugs, and devices are readily available. This is partly attributed to the quality of resuscitation, which is an important determinant of survival for patients who experience cardiac arrest. Systems problems, such as deficiencies in the physical space or equipment design, hospital-level policies, work culture, and poor leadership and teamwork, are now known to contribute significantly to the quality of resuscitation provided. We describe an in situ simulation-based quality improvement program that was designed to continuously monitor the cardiac arrest response process for hazards and defects and to detect opportunities for system optimization. A total of 72 simulated unannounced cardiac arrest exercises were conducted between October 2010 and September 2013 at various locations throughout our medical center and at different times of the day. We detected several environmental, human-machine interface, culture, and policy hazards and defects. We used the Systems Engineering Initiative for Patient Safety (SEIPS) model to understand the structure, processes, and outcomes related to the hospital's emergency response system. Multidisciplinary solutions were crafted for each of the hazards detected, and the simulation program was used to iteratively test the redesigned processes before implementation in real clinical settings. We describe an ongoing program that uses in situ simulation to identify and mitigate latent hazards and defects in the hospital emergency response system. The SEIPS model provides a framework for describing and analyzing the structure, processes, and outcomes related to these events.
Study of an automatic trajectory following control system
NASA Technical Reports Server (NTRS)
Vanlandingham, H. F.; Moose, R. L.; Zwicke, P. E.; Lucas, W. H.; Brinkley, J. D.
1983-01-01
It is shown that the estimator part of the Modified Partitioned Adaptive Controller, (MPAC) developed for nonlinear aircraft dynamics of a small jet transport can adapt to sensor failures. In addition, an investigation is made into the potential usefulness of the configuration detection technique used in the MPAC and the failure detection filter is developed that determines how a noise plant output is associated with a line or plane characteristic of a failure. It is shown by computer simulation that the estimator part and the configuration detection part of the MPAC can readily adapt to actuator and sensor failures and that the failure detection filter technique cannot detect actuator or sensor failures accurately for this type of system because of the plant modeling errors. In addition, it is shown that the decision technique, developed for the failure detection filter, can accurately determine that the plant output is related to the characteristic line or plane in the presence of sensor noise.
Fast neutron counting in a mobile, trailer-based search platform
NASA Astrophysics Data System (ADS)
Hayward, Jason P.; Sparger, John; Fabris, Lorenzo; Newby, Robert J.
2017-12-01
Trailer-based search platforms for detection of radiological and nuclear threats are often based upon coded aperture gamma-ray imaging, because this method can be rendered insensitive to local variations in gamma background while still localizing the source well. Since gamma source emissions are rather easily shielded, in this work we consider the addition of fast neutron counting to a mobile platform for detection of sources containing Pu. A proof-of-concept system capable of combined gamma and neutron coded-aperture imaging was built inside of a trailer and used to detect a 252Cf source while driving along a roadway. Neutron detector types employed included EJ-309 in a detector plane and EJ-299-33 in a front mask plane. While the 252Cf gamma emissions were not readily detectable while driving by at 16.9 m standoff, the neutron emissions can be detected while moving. Mobile detection performance for this system and a scaled-up system design are presented, along with implications for threat sensing.
NASA Technical Reports Server (NTRS)
Chesnutwood, C. M. (Principal Investigator)
1976-01-01
The author has identified the following significant results. Episodic phenomena such as rainfall shortly before data pass, thin translucent clouds, cloud shadows, and aircraft condensation trails and their shadows are responsible for changes in the spectral reflectivities of some surfaces. These changes are readily detected on LANDSAT full-frame imagery. Histograms of selected areas in Kansas show a distinct decrease in mean radiance values, but also, an increase in scene contrast, in areas where recent rains had occurred. Histograms from a few individual fields indicate that the mean radiance values for winter wheat followed a different trend after a rainfall than alfalfa or grasses.
Infrared search and track performance estimates for detection of commercial unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Nicholas, Robert; Driggers, Ronald; Shelton, David; Furxhi, Orges
2018-04-01
Unmanned aerial vehicles (UAVs) have become more readily available in the past 5 years and are proliferating rapidly. New aviation regulations are accelerating the use of UAVs in many applications. As a result, there are increasing concerns of potential air threats in situational environments including commercial airport security and drug trafficking. In this study, radiometric signatures of commercially available miniature UAVs is determined for long-wave infrared (LWIR) bands in both clear sky and partial cloudy conditions. Results are presented that compare LWIR performance estimates for the detection of commercial UAVs via infrared search and track (IRST) systems with two candidate sensors.
Developments in the Identification of Glycan Biomarkers for the Detection of Cancer
Ruhaak, L. Renee; Miyamoto, Suzanne; Lebrilla, Carlito B.
2013-01-01
Changes in glycosylation readily occur in cancer and other disease states. Thanks to recent advances in the development of analytical techniques and instrumentation, especially in mass spectrometry, it is now possible to identify blood-derived glycan-based biomarkers using glycomics strategies. This review is an overview of the developments made in the search for glycan-based cancer biomarkers and the technologies currently in use. It is anticipated that the progressing instrumental and bioinformatics developments will allow the identification of relevant glycan biomarkers for the diagnosis, early detection, and monitoring of cancer treatment with sufficient sensitivity and specificity for clinical use. PMID:23365456
Applications of everyday IT and communications devices in modern analytical chemistry: A review.
Grudpan, Kate; Kolev, Spas D; Lapanantnopakhun, Somchai; McKelvie, Ian D; Wongwilai, Wasin
2015-05-01
This paper reviews the development and recent use of everyday communications and IT equipment (mobile phones, digital cameras, scanners, webcams, etc) as detection devices for colorimetric chemistries. Such devices can readily be applied for visible detection using reaction formats such as microfluidic paper based analytical devices (µPADs), indicator papers, and well plate reaction vessels. Their use is highly advantageous with respect to cost, simplicity and portability, and offers many opportunities in the areas of point of care diagnosis, and at-site monitoring of environmental, agricultural, food and beverage parameters. Copyright © 2015 Elsevier B.V. All rights reserved.
Pennell, William E.; Sutton, Jr., Harry G.
1981-01-01
Method and apparatus for detecting failure in a welded connection, particrly applicable to not readily accessible welds such as those joining components within the reactor vessel of a nuclear reactor system. A preselected tag gas is sealed within a chamber which extends through selected portions of the base metal and weld deposit. In the event of a failure, such as development of a crack extending from the chamber to an outer surface, the tag gas is released. The environment about the welded area is directed to an analyzer which, in the event of presence of the tag gas, evidences the failure. A trigger gas can be included with the tag gas to actuate the analyzer.
Spatially Refined Aerosol Direct Radiative Focusing Efficiencies
Global aerosol direct radiative forcing (DRF) is an important metric for assessing potential climate impacts of future emissions changes. However, the radiative consequences of emissions perturbations are not readily quantified nor well understood at the level of detail necessary...
Spatially Refined Aerosol Direct Radiative Forcing Efficiencies
Global aerosol direct radiative forcing (DRF) is an important metric for assessing potential climate impacts of future emissions changes. However, the radiative consequences of emissions perturbations are not readily quantified nor well understood at the level of detail necessary...
Rapid Radiochemical Methods for Asphalt Paving Material ...
Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice
Neural network for intelligent query of an FBI forensic database
NASA Astrophysics Data System (ADS)
Uvanni, Lee A.; Rainey, Timothy G.; Balasubramanian, Uma; Brettle, Dean W.; Weingard, Fred; Sibert, Robert W.; Birnbaum, Eric
1997-02-01
Examiner is an automated fired cartridge case identification system utilizing a dual-use neural network pattern recognition technology, called the statistical-multiple object detection and location system (S-MODALS) developed by Booz(DOT)Allen & Hamilton, Inc. in conjunction with Rome Laboratory. S-MODALS was originally designed for automatic target recognition (ATR) of tactical and strategic military targets using multisensor fusion [electro-optical (EO), infrared (IR), and synthetic aperture radar (SAR)] sensors. Since S-MODALS is a learning system readily adaptable to problem domains other than automatic target recognition, the pattern matching problem of microscopic marks for firearms evidence was analyzed using S-MODALS. The physics; phenomenology; discrimination and search strategies; robustness requirements; error level and confidence level propagation that apply to the pattern matching problem of military targets were found to be applicable to the ballistic domain as well. The Examiner system uses S-MODALS to rank a set of queried cartridge case images from the most similar to the least similar image in reference to an investigative fired cartridge case image. The paper presents three independent tests and evaluation studies of the Examiner system utilizing the S-MODALS technology for the Federal Bureau of Investigation.
Lopata, M A; Cleveland, D W; Sollner-Webb, B
1984-01-01
Using a plasmid containing the bacterial chloramphenicol acetyl transferase gene, we have assayed for transient expression of DNA introduced into mouse L cells by a variety of transfection conditions. High efficiency uptake and expression of this foreign DNA have been achieved by modifying the DEAE dextran mediated transfection procedure of McCutchan and Pagano (1) to include a shock with either dimethyl sulfoxide or glycerol. Inclusion of the shock step can increase expression of the transfected gene a surprising approximately 50 fold. With plasmid constructs that do not replicate after transfection, we can readily detect CAT activity in an overnight autoradiographic exposure from less than 0.1% of an extract from a 60 mm dish of transfected cells. We have determined the amounts of DNA, the amount and time course of DEAE-dextran and dimethyl sulfoxide treatments, the effects of additional DNA, and the time after transfection which yield maximal expression. Overall, this transfection protocol using DEAE-dextran coupled to a shock treatment is simple, straightforward, and gives consistently high levels of expression of the input DNA. Images PMID:6589587
ERIC Educational Resources Information Center
Raykov, Tenko; Marcoulides, George A.
2015-01-01
A latent variable modeling procedure that can be used to evaluate intraclass correlation coefficients in two-level settings with discrete response variables is discussed. The approach is readily applied when the purpose is to furnish confidence intervals at prespecified confidence levels for these coefficients in setups with binary or ordinal…
Coeli Hoover; Linda S. Heath
2011-01-01
One method of increasing forest carbon stocks that is often discussed is increasing stocking levels on existing forested lands. However, estimates of the potential increases in forest carbon sequestration as a result of increased stocking levels are not readily available. Using the USDA Forest Service's Forest Inventory and Analysis data coupled with the Forest...
NASA Astrophysics Data System (ADS)
Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.
2003-09-01
A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development and comparisons of limits of detection. These instrumental methods are being optimized in order to detect the same target odor chemicals used by detector dogs to reliably locate explosives and ignitable liquids.
Effects of the diet on brain function
NASA Technical Reports Server (NTRS)
Fernstrom, J. D.
1981-01-01
The rates of synthesis by brain neurons of the neurotransmitters serotonin, acetylcholine, and the catecholamines depend on the brain levels of the respective precursor molecules. Brain levels of each precursor are influenced by their blood concentration, and for the amino acid precursors, by the blood levels of other amino acids as well. Since diet readily alters blood concentrations of each of these precursors, it thereby also influences the brain formation of their neutrotransmitter products.
Syndromic surveillance system based on near real-time cattle mortality monitoring.
Torres, G; Ciaravino, V; Ascaso, S; Flores, V; Romero, L; Simón, F
2015-05-01
Early detection of an infectious disease incursion will minimize the impact of outbreaks in livestock. Syndromic surveillance based on the analysis of readily available data can enhance traditional surveillance systems and allow veterinary authorities to react in a timely manner. This study was based on monitoring the number of cattle carcasses sent for rendering in the veterinary unit of Talavera de la Reina (Spain). The aim was to develop a system to detect deviations from expected values which would signal unexpected health events. Historical weekly collected dead cattle (WCDC) time series stabilized by the Box-Cox transformation and adjusted by the minimum least squares method were used to build the univariate cycling regression model based on a Fourier transformation. Three different models, according to type of production system, were built to estimate the baseline expected number of WCDC. Two types of risk signals were generated: point risk signals when the observed value was greater than the upper 95% confidence interval of the expected baseline, and cumulative risk signals, generated by a modified cumulative sum algorithm, when the cumulative sums of reported deaths were above the cumulative sum of expected deaths. Data from 2011 were used to prospectively validate the model generating seven risk signals. None of them were correlated to infectious disease events but some coincided, in time, with very high climatic temperatures recorded in the region. The harvest effect was also observed during the first week of the study year. Establishing appropriate risk signal thresholds is a limiting factor of predictive models; it needs to be adjusted based on experience gained during the use of the models. To increase the sensitivity and specificity of the predictions epidemiological interpretation of non-specific risk signals should be complemented by other sources of information. The methodology developed in this study can enhance other existing early detection surveillance systems. Syndromic surveillance based on mortality monitoring can reduce the detection time for certain disease outbreaks associated with mild mortality only detected at regional level. The methodology can be adapted to monitor other parameters routinely collected at farm level which can be influenced by communicable diseases. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhou, Zhenpeng; Li, Tian; Huang, Hongduan; Chen, Yang; Liu, Feng; Huang, Chengzhi; Li, Na
2014-11-11
Silver-enhanced fluorescence was coupled with a bio-barcode assay to facilitate a dual amplification assay to demonstrate a non-enzymatic approach for simple and sensitive detection of DNA. In the assay design, magnetic nanoparticles seeded with silver nanoparticles were modified with the capture DNA, and silver nanoparticles were modified with the binding of ssDNA and the fluorescently labeled barcode dsDNA. Upon introduction of the target DNA, a sandwich structure was formed because of the hybridization reaction. By simple magnetic separation, silver-enhanced fluorescence of barcode DNAs could be readily measured without the need of a further step to liberate barcode DNAs from silver nanoparticles, endowing the method with simplicity and high sensitivity with a detection limit of 1 pM.
Evaluation of eddy current and magnetic techniques for inspecting rebars in bridge barrier rails
NASA Astrophysics Data System (ADS)
Lo, C. C. H.; Nakagawa, N.
2013-01-01
This paper reports on a feasibility study of using eddy current (EC) and magnetic flux leakage (MFL) methods to detect corrosion damage in rebars that anchor concrete barrier rails to the road deck of bridge structures. EC and MFL measurements were carried out on standalone rebars with and without artificial defects of 25% and 50% material loss, using a commercial EC-based rebar locator and a MFL system that was developed using giant magnetoresistance sensors to detect leakage fluxes from the defects. Both techniques can readily detect the defects at a distance of 2.5″ (63.5 mm). The amplitudes of the EC and MFL signals vary monotonically with the amount of material loss, indicating the potential of using the techniques to quantify material loss of standalone rebars.
NASA Technical Reports Server (NTRS)
Allen, John
2001-01-01
Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCI), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.
Electrophoretic and field-effect graphene for all-electrical DNA array technology.
Xu, Guangyu; Abbott, Jeffrey; Qin, Ling; Yeung, Kitty Y M; Song, Yi; Yoon, Hosang; Kong, Jing; Ham, Donhee
2014-09-05
Field-effect transistor biomolecular sensors based on low-dimensional nanomaterials boast sensitivity, label-free operation and chip-scale construction. Chemical vapour deposition graphene is especially well suited for multiplexed electronic DNA array applications, since its large two-dimensional morphology readily lends itself to top-down fabrication of transistor arrays. Nonetheless, graphene field-effect transistor DNA sensors have been studied mainly at single-device level. Here we create, from chemical vapour deposition graphene, field-effect transistor arrays with two features representing steps towards multiplexed DNA arrays. First, a robust array yield--seven out of eight transistors--is achieved with a 100-fM sensitivity, on par with optical DNA microarrays and at least 10 times higher than prior chemical vapour deposition graphene transistor DNA sensors. Second, each graphene acts as an electrophoretic electrode for site-specific probe DNA immobilization, and performs subsequent site-specific detection of target DNA as a field-effect transistor. The use of graphene as both electrode and transistor suggests a path towards all-electrical multiplexed graphene DNA arrays.
Lavenant, Gwendoline Thiery; Zavalin, Andrey I.; Caprioli, Richard M.
2013-01-01
Targeted multiplex Imaging Mass Spectrometry utilizes several different antigen-specific primary antibodies, each directly labeled with a unique photocleavable mass tag, to detect multiple antigens in a single tissue section. Each photocleavable mass tag bound to an antibody has a unique molecular weight and can be readily ionized by laser desorption ionization mass spectrometry. This manuscript describes a mass spectrometry method that allows imaging of targeted single cells within tissue using transmission geometry laser desorption ionization mass spectrometry. Transmission geometry focuses the laser beam on the back side of the tissue placed on a glass slide, providing a 2 μm diameter laser spot irradiating the biological specimen. This matrix-free method enables simultaneous localization at the sub-cellular level of multiple antigens using specific tagged antibodies. We have used this technology to visualize the co-expression of synaptophysin and two major hormones peptides, insulin and somatostatin, in duplex assays in beta and delta cells contained in a human pancreatic islet. PMID:23397138
Qian, Chunqi; Murphy-Boesch, Joseph; Dodd, Stephen; Koretsky, Alan
2012-09-01
A completely wireless detection coil with an integrated parametric amplifier has been constructed to provide local amplification and transmission of MR signals. The sample coil is one element of a parametric amplifier using a zero-bias diode that mixes the weak MR signal with a strong pump signal that is obtained from an inductively coupled external loop. The NMR sample coil develops current gain via reduction in the effective coil resistance. Higher gain can be obtained by adjusting the level of the pumping power closer to the oscillation threshold, but the gain is ultimately constrained by the bandwidth requirement of MRI experiments. A feasibility study here shows that on a NaCl/D(2) O phantom, (23) Na signals with 20 dB of gain can be readily obtained with a concomitant bandwidth of 144 kHz. This gain is high enough that the integrated coil with parametric amplifier, which is coupled inductively to external loops, can provide sensitivity approaching that of direct wire connection. Copyright © 2012 Wiley Periodicals, Inc.
Hsieh, Hua-Yi; Li, Li-Hua; Hsu, Ren-Yu; Kao, Wei-Fong; Huang, Ying-Chen; Hsu, Cheng-Chih
2017-06-06
Blood testing for endogenous small metabolites to determine physiological and biochemical states is routine for laboratory analysis. Here we demonstrate that by combining the commercial direct analysis in real time (DART) ion source with an ion trap mass spectrometer, native cholesterol in its free alcohol form is readily detected from a few hundred nanoliters of human serum loaded onto chromatography paper. Deuterium-labeled cholesterol was used as the internal standard to obtain the absolute quantity of the endogenous cholesterol. The amount of the cholesterol measured by this paper-loaded DART mass spectrometry (pDART-MS) is statistically comparable with that obtained by using commercially available fluorometric-enzymatic assay and liquid chromatography/mass spectrometry. Furthermore, sera from 21 participants at three different time points in an ultramarathon were collected to obtain their cholesterol levels. The test requires only very minimal sample preparation, and the concentrations of cholesterol in each sample were acquired within a minute.
Acoustic emission testing on an F/A-18 E/F titanium bulkhead
NASA Astrophysics Data System (ADS)
Martin, Christopher A.; Van Way, Craig B.; Lockyer, Allen J.; Kudva, Jayanth N.; Ziola, Steve M.
1995-04-01
An important opportunity recently transpired at Northrop Grumman Corporation to instrument an F/A - 18 E/F titanium bulkhead with broad band acoustic emission sensors during a scheduled structural fatigue test. The overall intention of this effort was to investigate the potential for detecting crack propagation using acoustic transmission signals for a large structural component. Key areas of experimentation and experience included (1) acoustic noise characterization, (2) separation of crack signals from extraneous noise, (3) source location accuracy, and (4) methods of acoustic transducer attachment. Fatigue cracking was observed and monitored by strategically placed acoustic emission sensors. The outcome of the testing indicated that accurate source location still remains enigmatic for non-specialist engineering personnel especially at this level of structural complexity. However, contrary to preconceived expectations, crack events could be readily separated from extraneous noise. A further dividend from the investigation materialized in the form of close correspondence between frequency domain waveforms of the bulkhead test specimen tested and earlier work with thick plates.
NASA Astrophysics Data System (ADS)
Thiery-Lavenant, Gwendoline; Zavalin, Andre I.; Caprioli, Richard M.
2013-04-01
Targeted multiplex imaging mass spectrometry utilizes several different antigen-specific primary antibodies, each directly labeled with a unique photocleavable mass tag, to detect multiple antigens in a single tissue section. Each photocleavable mass tag bound to an antibody has a unique molecular weight and can be readily ionized by laser desorption ionization mass spectrometry. This article describes a mass spectrometry method that allows imaging of targeted single cells within tissue using transmission geometry laser desorption ionization mass spectrometry. Transmission geometry focuses the laser beam on the back side of the tissue placed on a glass slide, providing a 2 μm diameter laser spot irradiating the biological specimen. This matrix-free method enables simultaneous localization at the sub-cellular level of multiple antigens using specific tagged antibodies. We have used this technology to visualize the co-expression of synaptophysin and two major hormones peptides, insulin and somatostatin, in duplex assays in beta and delta cells contained in a human pancreatic islet.
Hossain, M Ismail; El-Harbawi, Mohanad; Alitheen, Noorjahan Banu Mohamed; Noaman, Yousr Abdulhadi; Lévêque, Jean-Marc; Yin, Chun-Yang
2013-01-01
Three 1-(2-hydroxyethyl)-3-alkylimidazolium chloride room temperature ionic liquids (ILs) [2OHimC(n)][Cl]; (n=0, 1, 4) have been synthesized from the appropriate imidazole precursors and characterized by IR and NMR spectroscopies and elemental analysis. Their anti-microbial activities were investigated using the well-diffusion method. The viabilities of Escherichia coli, Aeromonas hydrophila, Listeria monocytogenes and Salmonella enterica as a function of IL concentrations were studied. The minimal inhibitory concentrations (MICs) and EC₅₀ values for the present ILs were within the concentration range from 60 to 125 mM and 23 to 73 mM. The anti-microbial potencies of the present ILs were compared to a standard antibiotic, gentamicin. The finding affords additional perspective on the level of ILs toxicity to aquatic lifeforms and yet, this characteristic can be readily harnessed to detect microbial growth and activity. Copyright © 2012 Elsevier Inc. All rights reserved.
Detection of disseminated peritoneal tumors by fluorescein diacrylate in mice
NASA Astrophysics Data System (ADS)
Harada, Yoshinori; Furuta, Hirokazu; Murayama, Yasutoshi; Dai, Ping; Fujikawa, Yuta; Urano, Yasuteru; Nagano, Tetsuo; Morishita, Koki; Hasegawa, Akira; Takamatsu, Tetsuro
2009-02-01
Tumor invasion to the peritoneum is a poor prognostic factor in cancer patients. Accurate diagnosis of disseminated peritoneal tumors is essential to accurate cancer staging. To date, peritoneal washing cytology during laparotomy has been used for diagnosis of peritoneal dissemination of gastrointestinal cancer, but its sensitivity has not been satisfactory. Thus, a more direct approach is indispensable to detect peritoneal dissemination in vivo. Fluorescein diacrylate (FDAcr) is an esterase-sensitive fluorescent probe derived from fluorescein. In cancer cells, fluorescent fluorescein generated by exogenous application of FDAcr selectively deposits owing to its stronger hydrolytic enzyme activity and its lower leakage rate. We examined whether FDAcr can specifically detect disseminated peritoneal tumors in athymic nude mouse models. Intraperitoneally administered FDAcr revealed disseminated peritoneal microscopic tumors not readily recognized on white-light imaging. These results suggest that FDAcr is a useful probe for detecting disseminated peritoneal tumors.
Offset-free rail-to-rail derandomizing peak detect-and-hold circuit
DeGeronimo, Gianluigi; O'Connor, Paul; Kandasamy, Anand
2003-01-01
A peak detect-and-hold circuit eliminates errors introduced by conventional amplifiers, such as common-mode rejection and input voltage offset. The circuit includes an amplifier, three switches, a transistor, and a capacitor. During a detect-and-hold phase, a hold voltage at a non-inverting in put terminal of the amplifier tracks an input voltage signal and when a peak is reached, the transistor is switched off, thereby storing a peak voltage in the capacitor. During a readout phase, the circuit functions as a unity gain buffer, in which the voltage stored in the capacitor is provided as an output voltage. The circuit is able to sense signals rail-to-rail and can readily be modified to sense positive, negative, or peak-to-peak voltages. Derandomization may be achieved by using a plurality of peak detect-and-hold circuits electrically connected in parallel.
An Optoelectronic Nose for Detection of Toxic Gases
Lim, Sung H.; Feng, Liang; Kemling, Jonathan W.; Musto, Christopher J.; Suslick, Kenneth S.
2009-01-01
We have developed a simple colorimetric sensor array (CSA) for the detection of a wide range of volatile analytes and applied it to the detection of toxic gases. The sensor consists of a disposable array of cross-responsive nanoporous pigments whose colors are changed by diverse chemical interactions with analytes. Although no single chemically responsive pigment is specific for any one analyte, the pattern of color change for the array is a unique molecular fingerprint. Clear differentiation among 19 different toxic industrial chemicals (TICs) within two minutes of exposure at IDLH (immediately dangerous to life or health) concentration has been demonstrated. Quantification of each analyte is easily accomplished based on the color change of the array, and excellent detection limits have been demonstrated, generally below the PELs (permissible exposure limits). Identification of the TICs was readily achieved using a standard chemometric approach, i.e., hierarchical clustering analysis (HCA), with no misclassifications over 140 trials. PMID:20160982
Simple colorimetric detection of doxycycline and oxytetracycline using unmodified gold nanoparticles
NASA Astrophysics Data System (ADS)
Li, Jie; Fan, Shumin; Li, Zhigang; Xie, Yuanzhe; Wang, Rui; Ge, Baoyu; Wu, Jing; Wang, Ruiyong
2014-08-01
The interaction between tetracycline antibiotics and gold nanoparticles was studied. With citrate-coated gold nanoparticles as colorimetric probe, a simple and rapid detection method for doxycycline and oxytetracycline has been developed. This method relies on the distance-dependent optical properties of gold nanoparticles. In weakly acidic buffer medium, doxycycline and oxytetracycline could rapidly induce the aggregation of gold nanoparticles, resulting in red-to-blue (or purple) colour change. The experimental parameters were optimized with regard to pH, the concentration of the gold nanoparticles and the reaction time. Under optimal experimental conditions, the linear range of the colorimetric sensor for doxycycline/oxytetracycline was 0.06-0.66 and 0.59-8.85 μg mL-1, respectively. The corresponding limit of detection for doxycycline and oxytetracycline was 0.0086 and 0.0838 μg mL-1, respectively. This assay was sensitive, selective, simple and readily used to detect tetracycline antibiotics in food products.
An optoelectronic nose for the detection of toxic gases.
Lim, Sung H; Feng, Liang; Kemling, Jonathan W; Musto, Christopher J; Suslick, Kenneth S
2009-10-01
We have developed a simple colorimetric sensor array that detects a wide range of volatile analytes and then applied it to the detection of toxic gases. The sensor consists of a disposable array of cross-responsive nanoporous pigments with colours that are changed by diverse chemical interactions with analytes. Although no single chemically responsive pigment is specific for any one analyte, the pattern of colour change for the array is a unique molecular fingerprint. Clear differentiation among 19 different toxic industrial chemicals (TICs) within two minutes of exposure at concentrations immediately dangerous to life or health were demonstrated. Based on the colour change of the array, quantification of each analyte was accomplished easily, and excellent detection limits were achieved, generally below the permissible exposure limits. Different TICs were identified readily using a standard chemometric approach (hierarchical clustering analysis), with no misclassifications over 140 trials.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-06
... that it is subject to significant competitive forces, as described below in the Exchange's statement... can readily favor competing venues if they deem fee levels at a particular venue to be excessive. In...
Fox, A
1999-05-28
Bacterial cellular polysaccharides are composed of a variety of sugar monomers. These sugars serve as chemical markers to identify specific species or genera or to determine their physiological status. Some of these markers can also be used for trace detection of bacteria or their constituents in complex clinical or environmental matrices. Analyses are performed, in our hands, employing hydrolysis followed by the alditol acetate derivatization procedure. Substantial improvements have been made to sample preparation including simplification and computer-controlled automation. For characterization of whole cell bacterial hydrolysates, sugars are analyzed by gas chromatography-mass spectrometry (GC-MS). Simple chromatograms are generated using selected ion monitoring (SIM). Using total ion GC-MS, sugars can be readily identified. In more complex clinical and environmental samples, markers for bacteria are present at sufficiently low concentrations that more advanced instrumentation, gas chromatography-tandem mass spectrometry (GC-MS-MS), is preferred for optimal analysis. Using multiple reaction monitoring, MS-MS is used (replacing more conventional SIM) to ignore extraneous chromatographic peaks. Triple quadrupole and ion trap GC-MS-MS instruments have both been used successfully. Absolute chemical identification of sugar markers at trace levels is achieved, using MS-MS, by the product spectrum.
Analysis of re-replication from deregulated origin licensing by DNA fiber spreading
Dorn, Elizabeth S.; Chastain, Paul D.; Hall, Jonathan R.; Cook, Jeanette Gowen
2009-01-01
A major challenge each human cell-division cycle is to ensure that DNA replication origins do not initiate more than once, a phenomenon known as re-replication. Acute deregulation of replication control ultimately causes extensive DNA damage, cell-cycle checkpoint activation and cell death whereas moderate deregulation promotes genome instability and tumorigenesis. In the absence of detectable increases in cellular DNA content however, it has been difficult to directly demonstrate re-replication or to determine if the ability to re-replicate is restricted to a particular cell-cycle phase. Using an adaptation of DNA fiber spreading we report the direct detection of re-replication on single DNA molecules from human chromosomes. Using this method we demonstrate substantial re-replication within 1 h of S phase entry in cells overproducing the replication factor, Cdt1. Moreover, a comparison of the HeLa cancer cell line to untransformed fibroblasts suggests that HeLa cells produce replication signals consistent with low-level re-replication in otherwise unperturbed cell cycles. Re-replication after depletion of the Cdt1 inhibitor, geminin, in an untransformed fibroblast cell line is undetectable by standard assays but readily quantifiable by DNA fiber spreading analysis. Direct evaluation of re-replicated DNA molecules will promote increased understanding of events that promote or perturb genome stability. PMID:19010964
Murphy, Sean C.; Fernandez-Pol, Sebastian; Chung, Paul H.; Prasanna Murthy, S. N.; Milne, Stephen B.; Salomao, Marcela; Brown, H. Alex; Lomasney, Jon W.; Mohandas, Narla
2007-01-01
Studies of detergent-resistant membrane (DRM) rafts in mature erythrocytes have facilitated identification of proteins that regulate formation of endovacuolar structures such as the parasitophorous vacuolar membrane (PVM) induced by the malaria parasite Plasmodium falciparum. However, analyses of raft lipids have remained elusive because detergents interfere with lipid detection. Here, we use primaquine to perturb the erythrocyte membrane and induce detergent-free buoyant vesicles, which are enriched in cholesterol and major raft proteins flotillin and stomatin and contain low levels of cytoskeleton, all characteristics of raft microdomains. Lipid mass spectrometry revealed that phosphatidylethanolamine and phosphatidylglycerol are depleted in endovesicles while phosphoinositides are highly enriched, suggesting raft-based endovesiculation can be achieved by simple (non–receptor-mediated) mechanical perturbation of the erythrocyte plasma membrane and results in sorting of inner leaflet phospholipids. Live-cell imaging of lipid-specific protein probes showed that phosphatidylinositol (4,5) bisphosphate (PIP2) is highly concentrated in primaquine-induced vesicles, confirming that it is an erythrocyte raft lipid. However, the malarial PVM lacks PIP2, although another raft lipid, phosphatidylserine, is readily detected. Thus, different remodeling/sorting of cytoplasmic raft phospholipids may occur in distinct endovacuoles. Importantly, erythrocyte raft lipids recruited to the invasion junction by mechanical stimulation may be remodeled by the malaria parasite to establish blood-stage infection. PMID:17526861
Zhang, Xiaoyu; Song, Chunxia; Yang, Ke; Hong, Wenwen; Lu, Ying; Yu, Ping; Mao, Lanqun
2018-04-17
Electrochemical aptasensors generally include three elements, that is, recognition element, signal-transformation element, and regeneration element. In this study, a new adenosine triphosphate (ATP) aptasensor is developed by combining three elements into one DNA oligonucleotide chain. In the DNA oligonucleotide chain, DNA aptamer is used as the recognition element, ferrocene group attached at the 3'-end of the aptamer is used as the signal-transformation element, and azobenzene moiety embedded into the DNA chain is used as the regeneration element. In addition to the similar analytical properties with the traditional ones, the aptasensor developed here is easily regenerated with UV-light irradiation. The current response recorded on the aptasensor increases with increasing the concentration of ATP in the incubation solution and is linear with the logarithm of ATP concentration in the range from 1 nM to 100 μM. The limit of detection is 0.5 nM (S/N = 3). The basal level of ATP in the rat brain cortex microdialysate is determined to be 21.33 ± 4.1 nM ( n = 3). After being challenged with ATP, the aptasensor could be readily regenerated by UV-light irradiation for more than seven cycles. The regeneration of the aptasensor is proposed to be regulated by conversing azobenzene from its trans to cis form under UV irradiation.
Duizer, Erwin; Rutjes, Saskia; de Roda Husman, Ana Maria; Schijven, Jack
2016-01-01
On 6 September 2014, the accidental release of 10(13) infectious wild poliovirus type 3 (WPV3) particles by a vaccine production plant in Belgium was reported. WPV3 was released into the sewage system and discharged directly to a wastewater treatment plant (WWTP) and subsequently into rivers that flowed to the Western Scheldt and the North Sea. No poliovirus was detected in samples from the WWTP, surface waters, mussels or sewage from the Netherlands. Quantitative microbial risk assessment (QMRA) showed that the infection risks resulting from swimming in Belgium waters were above 50% for several days and that the infection risk by consuming shellfish harvested in the eastern part of the Western Scheldt warranted a shellfish cooking advice. We conclude that the reported release of WPV3 has neither resulted in detectable levels of poliovirus in any of the samples nor in poliovirus circulation in the Netherlands. This QMRA showed that relevant data on water flows were not readily available and that prior assumptions on dilution factors were overestimated. A QMRA should have been performed by all vaccine production facilities before starting up large-scale culture of WPV to be able to implement effective interventions when an accident happens.
Singh, Amit Kishore; Rai, Govind Kumar; Singh, Major; Dubey, Suresh Kumar
2013-11-01
To elucidate whether the transgenic crop alters the rhizospheric bacterial community structure, a 2-year study was performed with Cry1Ac gene-inserted brinjal crop (Bt) and their near isogenic non-transformed trait (non-Bt). The event of Bt crop (VRBT-8) was screened using an insect bioassay and enzyme-linked immunosorbent assay. Soil moisture, NH4 (+)-N, NO3 (-)-N, and PO4 (-)-P level had non-significant variation. Quantitative polymerase chain reaction revealed that abundance of bacterial 16S rRNA gene copies were lower in soils associated with Bt brinjal. Microbial biomass carbon (MBC) showed slight reduction in Bt brinjal soils. Higher MBC values in the non-Bt crop soil may be attributed to increased root activity and availability of readily metabolizable carbon compounds. The restriction fragment length polymorphism of PCR-amplified rRNA gene fragments detected 13 different bacterial groups with the exclusive presence of β-Proteobacteria, Chloroflexus, Planctomycetes, and Fusobacteria in non-Bt, and Cyanobacteria and Bacteroidetes in Bt soils, respectively, reflecting minor changes in the community structure. Despite the detection of Cry1Ac protein in the rhizospheric soil, the overall impact of Cry1Ac expressing Bt brinjal was less compared to that due to seasonal changes.
NASA Technical Reports Server (NTRS)
Glavin, D. P.; Buch, A.; Cabane, M.; Coll, P.; Navarro-Gonzalez, R.; Mahaffy, P. R.
2005-01-01
One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.
[Detection of biofilm formation by selected pathogens relevant to the food industry].
Šilhová-Hrušková, L; Moťková, P; Šilha, D; Vytřasová, J
2015-09-01
Detection of biofilm formation by microbial pathogens relevant to the food industry and comparison of biofilm formation under different conditions of culture. The following microorganisms were selected for the study: Staphylococcus aureus, Listeria innocua, Listeria ivanovii, Cronobacter sakazakii, Cronobacter muytjensii, Arcobacter butzleri, Arcobacter cryaerophilus, Campylobacter jejuni, and Campylobacter coli. To detect biofilm formation the microtiter plate assay, as described by Christensen and culture on stainless steel coupons were used. The biofilm forming capacity was confirmed in all microorganisms tested, both on the microtiter plates and stainless steel coupons. Biofilm formation was influenced by the culture medium, material used, and culture duration as well as by the test microorganism. It was found that different species and strains of the same genus differ in biofilm formation. Differences were also found between the collection strains and isolates from the environment. Some bacteria tended to form biofilm more readily on the surface of the polyethylene microtiter plates and less readily on stainless steel coupons while others appeared to have an opposite tendency. Some pathogens were able to increase the planktonic cell density in the initial suspension even by three orders of magnitude within 72 hours while producing plenty of biofilm. The study of biofilm formation by high risk pathogens is of utmost importance, not only to the food industry. From the obtained results, it is evident that bacterial biofilms form rapidly (within 24 hours in the present study). Due to their architecture, these biofilms are difficult to eradicate, and therefore, it is crucial to prevent biofilm formation.
Sabourin, Lyne; Beck, Andrew; Duenk, Peter W; Kleywegt, Sonya; Lapen, David R; Li, Hongxia; Metcalfe, Chris D; Payne, Michael; Topp, Edward
2009-08-01
Municipal biosolids are a useful source of nutrients for crop production, and commonly used in agriculture. In this field study, we applied dewatered municipal biosolids at a commercial rate using broadcast application followed by incorporation. Precipitation was simulated at 1, 3, 7, 21 and 34 days following the application on 2 m(2) microplots to evaluate surface runoff of various pharmaceuticals and personal care products (PPCPs), namely atenolol, carbamazepine, cotinine, caffeine, gemfibrozil, naproxen, ibuprofen, acetaminophen, sulfamethoxazole, triclosan and triclocarban. There was little temporal coherence in the detection of PPCPs in runoff, various compounds being detected maximally on days 1, 3, 7 or 36. Maximum concentrations in runoff ranged from below detection limit (gemfibrozil) to 109.7 ng L(-1) (triclosan). Expressing the total mass exported as a percentage of that applied, some analytes revealed little transport potential (<1% exported; triclocarban, triclosan, sulfamethoxazole, ibuprofen, naproxen and gemfibrozil) whereas others were readily exported (>1% exported; acetaminophen, carbamazepine, caffeine, cotinine, atenolol). Those compounds with little transport potential had log K(ow) values of 3.18 or greater, whereas those that were readily mobilized had K(ow) values of 2.45 or less. Maximal concentrations of all analytes were below toxic concentrations using a variety of endpoints available in the literature. In summary, this study has quantified the transport potential in surface runoff of PPCPs from land receiving biosolids, identified that log K(ow) may be a determinant of runoff transport potential of these analytes, and found maximal concentrations of all chemicals tested to be below toxic concentrations using a variety of endpoints.
Tsuchiya, N; Endo, T; Matsuta, K; Yoshinoya, S; Takeuchi, F; Nagano, Y; Shiota, M; Furukawa, K; Kochibe, N; Ito, K
1993-07-15
Although the galactose deficiency in the Asn297-linked sugar chains of serum IgG from patients with rheumatoid arthritis (RA) has been established, structural analysis of sugar chains has not been readily available. Psathyrella velutina lectin (PVL) preferentially interacts with the N-acetylglucosamine beta 1-->2Man group, exposed at the termini of sugar chains in agalacto IgG. Biotinylated PVL reacted strongly in Western blotting with H chains of IgG derived from patients with RA. An ELISA-based assay for the detection of agalacto IgG was developed using recombinant protein G and biotinylated PVL in combination, and the screening of patients' sera was performed. PVL binding of serum IgG significantly correlated with percentage of galactose-deficient IgG determined by the structural analysis. Age-related slight increase in PVL binding was observed among normal controls. Patients with RA showed significantly higher PVL binding (37.90 +/- 42.25 U/ml, n = 93) as compared with normal controls (5.75 +/- 2.92 U/ml, n = 112) (p = 0.0001). Patients with SLE showed lower but still significant PVL binding (17.86 +/- 5.18 U/ml, n = 10, p = 0.0001). PVL binding correlated with C-reactive protein level in serial analysis of individual RA patients, and was significantly higher in the synovial fluid compared with paired serum samples. PVL binding assay may provide an ideal tool for the simple and sensitive detection of agalacto IgG.
Alves, Júnia de O; Neto, Waldomiro B; Mitsutake, Hery; Alves, Paulo S P; Augusti, Rodinei
2010-07-15
Extra virgin (EV), the finest and most expensive among all the olive oil grades, is often adulterated by the cheapest and lowest quality ordinary (ON) olive oil. A new methodology is described herein that provides a simple, rapid, and accurate way not only to detect such type of adulteration, but also to distinguish between these olive oil grades (EV and ON). This approach is based on the application of direct infusion electrospray ionization mass spectrometry in the positive ion mode, ESI(+)-MS, followed by the treatment of the MS data via exploratory statistical approaches, PCA (principal component analysis) and HCA (hierarchical clustering analysis). Ten distinct brands of each EV and ON olive oil, acquired at local stores, were analyzed by ESI(+)-MS and the results from HCA and PCA clearly indicated the formation of two distinct groups related to these two categories. For the adulteration study, one brand of each olive oil grade (EV and ON) was selected. The counterfeit samples (a total of 20) were then prepared by adding assorted proportions, from 1 to 20% w/w, with increments of 1% w/w, of the ON to the EV olive oil. The PCA and HCA methodologies, applied to the ESI(+)-MS data from the counterfeit (20) and authentic (10) EV samples, were able to readily detect adulteration, even at levels as low as 1% w/w. Copyright 2010 John Wiley & Sons, Ltd.
Xie, Zhengzhi; Gang, David R.
2009-01-01
Turmeric is an excellent example of a plant that produces large numbers of metabolites from diverse metabolic pathways or networks. It is hypothesized that these metabolic pathways or networks contain biosynthetic modules, which lead to the formation of metabolite modules—groups of metabolites whose production is co-regulated and biosynthetically linked. To test whether such co-regulated metabolite modules do exist in this plant, metabolic profiling analysis was performed on turmeric rhizome samples that were collected from 16 different growth and development treatments, which had significant impacts on the levels of 249 volatile and non-volatile metabolites that were detected. Importantly, one of the many co-regulated metabolite modules that were indeed readily detected in this analysis contained the three major curcuminoids, whereas many other structurally related diarylheptanoids belonged to separate metabolite modules, as did groups of terpenoids. The existence of these co-regulated metabolite modules supported the hypothesis that the 3-methoxyl groups on the aromatic rings of the curcuminoids are formed before the formation of the heptanoid backbone during the biosynthesis of curcumin and also suggested the involvement of multiple polyketide synthases with different substrate selectivities in the formation of the array of diarylheptanoids detected in turmeric. Similar conclusions about terpenoid biosynthesis could also be made. Thus, discovery and analysis of metabolite modules can be a powerful predictive tool in efforts to understand metabolism in plants. PMID:19073964
Low-Resistance Spin Injection into Silicon Using Graphene Tunnel Barriers
2012-11-01
compromise spin injection/transport/detection. Ferromagnetic metals readily form silicides even at room tempera- ture19, and diffusion of the ferromagnetic... metal /tunnel barrier/Si contacts using 2 nm SiO2 (triangles), 1.5 nm Al2O3 (diamond) and monolayer graphene (circles) tunnel barriers prepared from...and B. T. Jonker* Spin manipulation in a semiconductor offers a new paradigm for device operation beyond Moore’s law. Ferromagnetic metals are ideal
Interfacial bioconjugation on emulsion droplet for biosensors.
Zhang, Qifan; Scigliano, Anita; Biver, Tarita; Pucci, Andrea; Swager, Timothy M
2018-04-13
Interfacial bioconjugation methods are developed for intact liquid emulsion droplets. Complex emulsion droplets having internal hydrocarbon and fluorocarbon immiscible structured phases maintain a dynamic interface for controlled interfacial reactivity. The internal morphological change after binding to biomolecules is readily visualized and detected by light transmission, which provides a platform for the formation of inexpensive and portable bio-sensing assays for enzymes, antibodies, nucleic acids and carbohydrates. Copyright © 2018. Published by Elsevier Ltd.
Direct Analysis of Large Living Organism by Megavolt Electrostatic Ionization Mass Spectrometry
NASA Astrophysics Data System (ADS)
Ng, Kwan-Ming; Tang, Ho-Wai; Man, Sin-Heng; Mak, Pui-Yuk; Choi, Yi-Ching; Wong, Melody Yee-Man
2014-09-01
A new ambient ionization method allowing the direct chemical analysis of living human body by mass spectrometry (MS) was developed. This MS method, namely Megavolt Electrostatic Ionization Mass Spectrometry, is based on electrostatic charging of a living individual to megavolt (MV) potential, illicit drugs, and explosives on skin/glove, flammable solvent on cloth/tissue paper, and volatile food substances in breath were readily ionized and detected by a mass spectrometer.
2010-01-01
scientific disciplines, who are rapidly pursuing a plethora of exciting and new applications. Concurrently, the implications for potential long-term...focus on the NP toxicity-associated bioeffects that produce acute dose-dependent decreases in viability and alterations in cell function (e.g...t h sufficient contrast and that only high atomic number NPs were readily detectable. More recently, de Jonge et al.25 have unveiled a new STEM
Detection of alkali-silica reaction swelling in concrete by staining
Guthrie, Jr., George D.; Carey, J. William
1998-01-01
A method using concentrated aqueous solutions of sodium cobaltinitrite and rhodamine B is described which can be used to identify concrete that contains gels formed by the alkali-silica reaction (ASR). These solutions present little health or environmental risk, are readily applied, and rapidly discriminate between two chemically distinct gels; K-rich, Na--K--Ca--Si gels are identified by yellow staining, and alkali-poor, Ca--Si gels are identified by pink staining.
Entangled state quantum cryptography: eavesdropping on the ekert protocol
Naik; Peterson; White; Berglund; Kwiat
2000-05-15
Using polarization-entangled photons from spontaneous parametric down-conversion, we have implemented Ekert's quantum cryptography protocol. The near-perfect correlations of the photons allow the sharing of a secret key between two parties. The presence of an eavesdropper is continually checked by measuring Bell's inequalities. We investigated several possible eavesdropper strategies, including pseudo-quantum-nondemolition measurements. In all cases, the eavesdropper's presence was readily apparent. We discuss a procedure to increase her detectability.
Yao, Chunlei; Xie, Changyan; Lin, Peng; Yan, Feng; Huang, Pingbo; Hsing, I-Ming
2013-12-03
An organic electrochemical transistor array is integrated with human airway epithelial cells. This integration provides a novel method to couple transepithelial ion transport with electrical current. Activation and inhibition of transepithelial ion transport are readily detected with excellent time resolution. The organic electrochemical transistor array serves as a promising platform for physiological studies and drug testing. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Spray-Deposited Superconductor/Polymer Coatings
NASA Technical Reports Server (NTRS)
Wise, Stephanie A.; Tran, Sang Q.; Hooker, Matthew W.
1993-01-01
Coatings that exhibit the Meissner effect formed at relatively low temperature. High-temperature-superconductor/polymer coatings that exhibit Meissner effect deposited onto components in variety of shapes and materials. Simple, readily available equipment needed in coating process, mean coatings produced economically. Coatings used to keep magnetic fields away from electronic circuits in such cryogenic applications as magnetic resonance imaging and detection of infrared, and in magnetic suspensions to provide levitation and/or damping of vibrations.
Direct analysis of large living organism by megavolt electrostatic ionization mass spectrometry.
Ng, Kwan-Ming; Tang, Ho-Wai; Man, Sin-Heng; Mak, Pui-Yuk; Choi, Yi-Ching; Wong, Melody Yee-Man
2014-09-01
A new ambient ionization method allowing the direct chemical analysis of living human body by mass spectrometry (MS) was developed. This MS method, namely Megavolt Electrostatic Ionization Mass Spectrometry, is based on electrostatic charging of a living individual to megavolt (MV) potential, illicit drugs, and explosives on skin/glove, flammable solvent on cloth/tissue paper, and volatile food substances in breath were readily ionized and detected by a mass spectrometer.
Helium ionization detection apparatus
NASA Technical Reports Server (NTRS)
Nagai, R.
1984-01-01
In a gas chromatograph apparatus comprising a gas supply (He carrier gas), a sample injection apparatus, a chromatograph column, a He ion detector, and connecting tubes, a foreign gas (other than He) injection apparatus is installed between the sample injection apparatus and the detector. Mixing of the sample gas and foreign gas takes place readily, the sample gas is always maintained at a stable concentrator range, and accurate measurements are possible, especially at low sample gas concentrations.
Automatic detection of echolocation clicks based on a Gabor model of their waveform.
Madhusudhana, Shyam; Gavrilov, Alexander; Erbe, Christine
2015-06-01
Prior research has shown that echolocation clicks of several species of terrestrial and marine fauna can be modelled as Gabor-like functions. Here, a system is proposed for the automatic detection of a variety of such signals. By means of mathematical formulation, it is shown that the output of the Teager-Kaiser Energy Operator (TKEO) applied to Gabor-like signals can be approximated by a Gaussian function. Based on the inferences, a detection algorithm involving the post-processing of the TKEO outputs is presented. The ratio of the outputs of two moving-average filters, a Gaussian and a rectangular filter, is shown to be an effective detection parameter. Detector performance is assessed using synthetic and real (taken from MobySound database) recordings. The detection method is shown to work readily with a variety of echolocation clicks and in various recording scenarios. The system exhibits low computational complexity and operates several times faster than real-time. Performance comparisons are made to other publicly available detectors including pamguard.
A new method for text detection and recognition in indoor scene for assisting blind people
NASA Astrophysics Data System (ADS)
Jabnoun, Hanen; Benzarti, Faouzi; Amiri, Hamid
2017-03-01
Developing assisting system of handicapped persons become a challenging ask in research projects. Recently, a variety of tools are designed to help visually impaired or blind people object as a visual substitution system. The majority of these tools are based on the conversion of input information into auditory or tactile sensory information. Furthermore, object recognition and text retrieval are exploited in the visual substitution systems. Text detection and recognition provides the description of the surrounding environments, so that the blind person can readily recognize the scene. In this work, we aim to introduce a method for detecting and recognizing text in indoor scene. The process consists on the detection of the regions of interest that should contain the text using the connected component. Then, the text detection is provided by employing the images correlation. This component of an assistive blind person should be simple, so that the users are able to obtain the most informative feedback within the shortest time.
A lightweight network anomaly detection technique
Kim, Jinoh; Yoo, Wucherl; Sim, Alex; ...
2017-03-13
While the network anomaly detection is essential in network operations and management, it becomes further challenging to perform the first line of detection against the exponentially increasing volume of network traffic. In this paper, we develop a technique for the first line of online anomaly detection with two important considerations: (i) availability of traffic attributes during the monitoring time, and (ii) computational scalability for streaming data. The presented learning technique is lightweight and highly scalable with the beauty of approximation based on the grid partitioning of the given dimensional space. With the public traffic traces of KDD Cup 1999 andmore » NSL-KDD, we show that our technique yields 98.5% and 83% of detection accuracy, respectively, only with a couple of readily available traffic attributes that can be obtained without the help of post-processing. Finally, the results are at least comparable with the classical learning methods including decision tree and random forest, with approximately two orders of magnitude faster learning performance.« less
Portable multispectral fluorescence imaging system for food safety applications
NASA Astrophysics Data System (ADS)
Lefcourt, Alan M.; Kim, Moon S.; Chen, Yud-Ren
2004-03-01
Fluorescence can be a sensitive method for detecting food contaminants. Of particular interest is detection of fecal contamination as feces is the source of many pathogenic organisms. Feces generally contain chlorophyll a and related compounds due to ingestion of plant materials, and these compounds can readily be detected using fluorescence techniques. Described is a fluorescence-imaging system consisting primarily of a UV light source, an intensified camera with a six-position filter wheel, and software for controlling the system and automatically analyzing the resulting images. To validate the system, orchard apples artificially contaminated with dairy feces were used in a "hands-on" public demonstration. The contamination sites were easily identified using automated edge detection and threshold detection algorithms. In addition, by applying feces to apples and then washing sets of apples at hourly intervals, it was determined that five h was the minimum contact time that allowed identification of the contamination site after the apples were washed. There are many potential uses for this system, including studying the efficacy of apple washing systems.
A lightweight network anomaly detection technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jinoh; Yoo, Wucherl; Sim, Alex
While the network anomaly detection is essential in network operations and management, it becomes further challenging to perform the first line of detection against the exponentially increasing volume of network traffic. In this paper, we develop a technique for the first line of online anomaly detection with two important considerations: (i) availability of traffic attributes during the monitoring time, and (ii) computational scalability for streaming data. The presented learning technique is lightweight and highly scalable with the beauty of approximation based on the grid partitioning of the given dimensional space. With the public traffic traces of KDD Cup 1999 andmore » NSL-KDD, we show that our technique yields 98.5% and 83% of detection accuracy, respectively, only with a couple of readily available traffic attributes that can be obtained without the help of post-processing. Finally, the results are at least comparable with the classical learning methods including decision tree and random forest, with approximately two orders of magnitude faster learning performance.« less
Bonar, Micha M.; Tilton, John C.
2017-01-01
Detection of viruses by flow cytometry is complicated by their small size. Here, we characterized the ability of a standard (FACSAria II) and a sub-micron flow cytometer (A50 Micro) to resolve HIV-1 viruses. The A50 was superior at resolving small particles but did not reliably distinguish HIV-1, extracellular vesicles, and laser noise by light scatter properties alone. However, single fluorescent HIV-1 particles could readily be detected by both cytometers. Fluorescent particles were sorted and retained infectivity, permitting further exploration of the functional consequences of HIV-1 heterogeneity. Finally, flow cytometry had a limit of detection of 80 viruses/ml, nearly equal to PCR assays. These studies demonstrate the power of flow cytometry to detect and sort viral particles and provide a critical toolkit to validate methods to label wild-type HIV-1; quantitatively assess integrity and aggregation of viruses and virus-based therapeutics; and efficiently screen drugs inhibiting viral assembly and release. PMID:28235684
Bonar, Michał M; Tilton, John C
2017-05-01
Detection of viruses by flow cytometry is complicated by their small size. Here, we characterized the ability of a standard (FACSAria II) and a sub-micron flow cytometer (A50 Micro) to resolve HIV-1 viruses. The A50 was superior at resolving small particles but did not reliably distinguish HIV-1, extracellular vesicles, and laser noise by light scatter properties alone. However, single fluorescent HIV-1 particles could readily be detected by both cytometers. Fluorescent particles were sorted and retained infectivity, permitting further exploration of the functional consequences of HIV-1 heterogeneity. Finally, flow cytometry had a limit of detection of 80 viruses/ml, nearly equal to PCR assays. These studies demonstrate the power of flow cytometry to detect and sort viral particles and provide a critical toolkit to validate methods to label wild-type HIV-1; quantitatively assess integrity and aggregation of viruses and virus-based therapeutics; and efficiently screen drugs inhibiting viral assembly and release. Copyright © 2017 Elsevier Inc. All rights reserved.
Investigations of remote sensing techniques for early detection of Dutch elm disease
NASA Technical Reports Server (NTRS)
Hammerschlag, R. S.; Sopstyle, W. J.
1975-01-01
Several forms of aerial photography were pursued in quest of a technique which could provide early detection of Dutch elm disease. The two most promising techniques tested were multispectral photography with object enhancement and biband ratioing coupled with scanning microdensitometry. For practical purposes the multispectral system has the advantage of providing a readily interpretable image in a relatively short time. Laboratory studies indicated that less emphasis should be placed on the use of a red filter or the near infrared beyond 750 mm for early detection of stress within a single plant species. Color infrared film would be optimal when used for a long term detection of loss of plant vigor which results in a physical change in a plant canopy, but should find minimal practicality for early detection of specific sources of plant stress such as Dutch elm disease. Considerable discretion should be used when interpreting imagery on copy film because of loss of resolution and color definition.
Spatio-temporal variation of coarse woody debris input in woodland key habitats in central Sweden
Mari Jonsson; Shawn Fraver; Bengt Gunnar. Jonsson
2011-01-01
The persistence of many saproxylic (wood-living) species depends on a readily available supply of coarse woody debris (CWD). Most studies of CWD inputs address stand-level patterns, despite the fact that many saproxylic species depend on landscape-level supplies of CWD. In the present study we used dated CWD inputs (tree mortality events) at each of 14 Norway spruce (...
Volume growth trends in a Douglas-fir levels-of-growing-stock study.
Robert O. Curtis
2006-01-01
Mean curves of increment and yield in gross total cubic volume and net merchantable cubic volume were derived from seven installations of the regional cooperative Levels-of-Growing-Stock Study (LOGS) in Douglas-fir. The technique used reduces the seven curves for each treatment for each variable of interest to a single set of readily interpretable mean curves. To a top...
Tarnow, Eugen
2009-09-01
The Tagging/Retagging model of short term memory was introduced earlier (Tarnow in Cogn Neurodyn 2(4):347-353, 2008) to explain the linear relationship between response time and correct response probability for word recall and recognition: At the initial stimulus presentation the words displayed tag the corresponding long term memory locations. The tagging process is linear in time and takes about one second to reach a tagging level of 100%. After stimulus presentation the tagging level decays logarithmically with time to 50% after 14 s and to 20% after 220 s. If a probe word is reintroduced the tagging level has to return to 100% for the word to be properly identified, which leads to a delay in response time. This delay is proportional to the tagging loss. The tagging level is directly related to the probability of correct word recall and recognition. Evidence presented suggests that the tagging level is the level of depletion of the Readily Releasable Pool (RRP) of neurotransmitter vesicles at presynaptic terminals. The evidence includes the initial linear relationship between tagging level and time as well as the subsequent logarithmic decay of the tagging level. The activation of a short term memory may thus be the depletion of RRP (exocytosis) and short term memory decay may be the ensuing recycling of the neurotransmitter vesicles (endocytosis). The pattern of depleted presynaptic terminals corresponds to the long term memory trace.
Designs for the combination of group- and individual-level data
Haneuse, Sebastien; Bartell, Scott
2012-01-01
Background Studies of ecologic or aggregate data suffer from a broad range of biases when scientific interest lies with individual-level associations. To overcome these biases, epidemiologists can choose from a range of designs that combine these group-level data with individual-level data. The individual-level data provide information to identify, evaluate, and control bias, while the group-level data are often readily accessible and provide gains in efficiency and power. Within this context, the literature on developing models, particularly multi-level models, is well-established, but little work has been published to help researchers choose among competing designs and plan additional data collection. Methods We review recently proposed “combined” group- and individual-level designs and methods that collect and analyze data at two levels of aggregation. These include aggregate data designs, hierarchical related regression, two-phase designs, and hybrid designs for ecologic inference. Results The various methods differ in (i) the data elements available at the group and individual levels and (ii) the statistical techniques used to combine the two data sources. Implementing these techniques requires care, and it may often be simpler to ignore the group-level data once the individual-level data are collected. A simulation study, based on birth-weight data from North Carolina, is used to illustrate the benefit of incorporating group-level information. Conclusions Our focus is on settings where there are individual-level data to supplement readily accessible group-level data. In this context, no single design is ideal. Choosing which design to adopt depends primarily on the model of interest and the nature of the available group-level data. PMID:21490533
de Vries, Rory D.; Ludlow, Martin; Verburgh, R. Joyce; van Amerongen, Geert; Yüksel, Selma; Nguyen, D. Tien; McQuaid, Stephen; Osterhaus, Albert D. M. E.; Duprex, W. Paul
2014-01-01
ABSTRACT Measles virus (MV) is being considered for global eradication, which would likely reduce compliance with MV vaccination. As a result, children will grow up without MV-specific immunity, creating a potential niche for closely related animal morbilliviruses such as canine distemper virus (CDV). Natural CDV infection causing clinical signs has never been reported in humans, but recent outbreaks in captive macaques have shown that CDV can cause disease in primates. We studied the virulence and tropism of recombinant CDV expressing enhanced green fluorescent protein in naive and measles-vaccinated cynomolgus macaques. In naive animals CDV caused viremia and fever and predominantly infected CD150+ lymphocytes and dendritic cells. Virus was reisolated from the upper and lower respiratory tracts, but infection of epithelial or neuronal cells was not detectable at the time points examined, and the infections were self-limiting. This demonstrates that CDV readily infects nonhuman primates but suggests that additional mutations are necessary to achieve full virulence in nonnatural hosts. Partial protection against CDV was observed in measles-vaccinated macaques, as demonstrated by accelerated control of virus replication and limited shedding from the upper respiratory tract. While neither CDV infection nor MV vaccination induced detectable cross-reactive neutralizing antibodies, MV-specific neutralizing antibody levels of MV-vaccinated macaques were boosted by CDV challenge infection, suggesting that cross-reactive VN epitopes exist. Rapid increases in white blood cell counts in MV-vaccinated macaques following CDV challenge suggested that cross-reactive cellular immune responses were also present. This study demonstrates that zoonotic morbillivirus infections can be controlled by measles vaccination. IMPORTANCE Throughout history viral zoonoses have had a substantial impact on human health. Given the drive toward global eradication of measles, it is essential to understand the zoonotic potential of animal morbilliviruses. Morbilliviruses are thought to have evolved from a common ancestral virus that jumped species and adapted to new hosts. Recently, canine distemper virus (CDV), a morbillivirus normally restricted to carnivores, caused disease outbreaks in nonhuman primates. Here, we report that experimental CDV infection of monkeys resulted in fever and leukopenia. The virus replicated to high levels in lymphocytes but did not spread to epithelial cells or the central nervous system. Importantly, like measles virus in macaques, the infections were self-limiting. In measles-vaccinated macaques CDV was cleared more rapidly, resulting in limited virus shedding from the upper respiratory tract. These studies demonstrate that although CDV can readily infect primates, measles immunity is protective, and CDV infection is self-limiting. PMID:24501402
de Vries, Rory D; Ludlow, Martin; Verburgh, R Joyce; van Amerongen, Geert; Yüksel, Selma; Nguyen, D Tien; McQuaid, Stephen; Osterhaus, Albert D M E; Duprex, W Paul; de Swart, Rik L
2014-04-01
Measles virus (MV) is being considered for global eradication, which would likely reduce compliance with MV vaccination. As a result, children will grow up without MV-specific immunity, creating a potential niche for closely related animal morbilliviruses such as canine distemper virus (CDV). Natural CDV infection causing clinical signs has never been reported in humans, but recent outbreaks in captive macaques have shown that CDV can cause disease in primates. We studied the virulence and tropism of recombinant CDV expressing enhanced green fluorescent protein in naive and measles-vaccinated cynomolgus macaques. In naive animals CDV caused viremia and fever and predominantly infected CD150(+) lymphocytes and dendritic cells. Virus was reisolated from the upper and lower respiratory tracts, but infection of epithelial or neuronal cells was not detectable at the time points examined, and the infections were self-limiting. This demonstrates that CDV readily infects nonhuman primates but suggests that additional mutations are necessary to achieve full virulence in nonnatural hosts. Partial protection against CDV was observed in measles-vaccinated macaques, as demonstrated by accelerated control of virus replication and limited shedding from the upper respiratory tract. While neither CDV infection nor MV vaccination induced detectable cross-reactive neutralizing antibodies, MV-specific neutralizing antibody levels of MV-vaccinated macaques were boosted by CDV challenge infection, suggesting that cross-reactive VN epitopes exist. Rapid increases in white blood cell counts in MV-vaccinated macaques following CDV challenge suggested that cross-reactive cellular immune responses were also present. This study demonstrates that zoonotic morbillivirus infections can be controlled by measles vaccination. Throughout history viral zoonoses have had a substantial impact on human health. Given the drive toward global eradication of measles, it is essential to understand the zoonotic potential of animal morbilliviruses. Morbilliviruses are thought to have evolved from a common ancestral virus that jumped species and adapted to new hosts. Recently, canine distemper virus (CDV), a morbillivirus normally restricted to carnivores, caused disease outbreaks in nonhuman primates. Here, we report that experimental CDV infection of monkeys resulted in fever and leukopenia. The virus replicated to high levels in lymphocytes but did not spread to epithelial cells or the central nervous system. Importantly, like measles virus in macaques, the infections were self-limiting. In measles-vaccinated macaques CDV was cleared more rapidly, resulting in limited virus shedding from the upper respiratory tract. These studies demonstrate that although CDV can readily infect primates, measles immunity is protective, and CDV infection is self-limiting.
Thermocron iButton and iBBat temperature dataloggers emit ultrasound.
Willis, Craig K R; Jameson, Joel W; Faure, Paul A; Boyles, Justin G; Brack, Virgil; Cervone, Tom H
2009-10-01
Thermocron iButton dataloggers are widely used to measure thermal microclimates experienced by wild animals. The iBBat is a smaller version of the datalogger, also commercially available, that is used to measure animal skin or core body temperatures when attached externally or surgically implanted. Field observations of bats roosting under a bridge suggested that bats avoided locations with iButtons. A heterodyne bat detector revealed that the dataloggers emitted ultrasound which was detectable from a distance of up to 30 cm. We therefore recorded and quantified the acoustic properties [carrier frequency (Hz) and root mean square sound pressure level (dB SPL)] of iButton and iBBat dataloggers. All units emitted a 32.9 kHz pure tone that was readily picked up with a time expansion bat detector at a distance of 1 cm, and most were detected at a distance of 15 cm. The maximum amplitude of iButton dataloggers was 46.5 dB SPL at 1.0 cm-a level within the range of auditory sensitivity for most small mammals. Wrapping iButtons in plastic insulation severely attenuated the amplitude of ultrasound. Although there was a statistically significant reduction in rates of warming and cooling with insulation, this effect was small and we suggest that insulation may be a viable solution to eliminate unwanted ultrasonic noise in instances when small delays in thermal response dynamics are not a concern. We recommend behavioural studies to assess if the electronic signals emitted by iButtons are disturbing to small mammals.
Palanisamy, Navaneethan; Goedecke, Ulrike; Jäger, Nils; Pöhlmann, Stefan; Winkler, Michael
2014-01-01
Reporter genes inserted into viral genomes enable the easy and rapid quantification of virus replication, which is instrumental to efficient in vitro screening of antiviral compounds or in vivo analysis of viral spread and pathogenesis. Based on a published design, we have generated several replication competent influenza A viruses carrying either fluorescent proteins or Gaussia luciferase. Reporter activity could be readily quantified in infected cultures, but the virus encoding Gaussia luciferase was more stable than viruses bearing fluorescent proteins and was therefore analyzed in detail. Quantification of Gaussia luciferase activity in the supernatants of infected culture allowed the convenient and highly sensitive detection of viral spread, and enzymatic activity correlated with the number of infectious particles released from infected cells. Furthermore, the Gaussia luciferase encoding virus allowed the sensitive quantification of the antiviral activity of the neuraminidase inhibitor (NAI) zanamivir and the host cell interferon-inducible transmembrane (IFITM) proteins 1–3, which are known to inhibit influenza virus entry. Finally, the virus was used to demonstrate that influenza A virus infection is sensitive to a modulator of endosomal cholesterol, in keeping with the concept that IFITMs inhibit viral entry by altering cholesterol levels in the endosomal membrane. In sum, we report the characterization of a novel influenza A reporter virus, which allows fast and sensitive detection of viral spread and its inhibition, and we show that influenza A virus entry is sensitive to alterations of endosomal cholesterol levels. PMID:24842154
Motion detection using extended fractional Fourier transform and digital speckle photography.
Bhaduri, Basanta; Tay, C J; Quan, C; Sheppard, Colin J R
2010-05-24
Digital speckle photography is a useful tool for measuring the motion of optically rough surfaces from the speckle shift that takes place at the recording plane. A simple correlation based digital speckle photographic system has been proposed that implements two simultaneous optical extended fractional Fourier transforms (EFRTs) of different orders using only a single lens and detector to simultaneously detect both the magnitude and direction of translation and tilt by capturing only two frames: one before and another after the object motion. The dynamic range and sensitivity of the measurement can be varied readily by altering the position of the mirror/s used in the optical setup. Theoretical analysis and experiment results are presented.
Higher Throughput Calorimetry: Opportunities, Approaches and Challenges
Recht, Michael I.; Coyle, Joseph E.; Bruce, Richard H.
2010-01-01
Higher throughput thermodynamic measurements can provide value in structure-based drug discovery during fragment screening, hit validation, and lead optimization. Enthalpy can be used to detect and characterize ligand binding, and changes that affect the interaction of protein and ligand can sometimes be detected more readily from changes in the enthalpy of binding than from the corresponding free-energy changes or from protein-ligand structures. Newer, higher throughput calorimeters are being incorporated into the drug discovery process. Improvements in titration calorimeters come from extensions of a mature technology and face limitations in scaling. Conversely, array calorimetry, an emerging technology, shows promise for substantial improvements in throughput and material utilization, but improved sensitivity is needed. PMID:20888754
Large-bodied Demodex mite infestation in 4 dogs.
Hillier, Andrew; Desch, Clifford E
2002-03-01
Large-bodied Demodex mites were detected in 4 dogs. The mites were readily detected in material obtained via deep skin scrapings and were most commonly found on the trunk. The mites were distinguishable from D. canis, because adult males were approximately 100% longer and adult females were approximately 50% longer than adult male and female D. canis mites, respectively. The large-bodied mites were found in the hair follicles, sebaceous ducts, and sebaceous glands in histologic sections of skin from 2 dogs. All dogs had adult-onset generalized demodicosis. Two dogs had coexistent iatrogenic hypercortisolism, 1 dog had hypothyroidism, and 1 dog did not have coexistent disease. Infestations responded to miticidal therapy, control of the coexistent disease, or both.
Cornelis, Justien; Denis, Tim; Beckers, Paul; Vrints, Christiaan; Vissers, Dirk; Goossens, Maggy
2017-08-01
Cardiopulmonary exercise testing (CPET) gained importance in the prognostic assessment of especially patients with heart failure (HF). A meaningful prognostic parameter for early mortality in HF is exercise oscillatory ventilation (EOV). This abnormal respiratory pattern is recognized by hypo- and hyperventilation during CPET. Up until now, assessment of EOV is mainly done upon visual agreement or manual calculation. The purpose of this research was to automate the interpretation of EOV so this prognostic parameter could be readily investigated during CPET. Preliminary, four definitions describing the original characteristics of EOV, were selected and integrated in the "Ventilatory Oscillations during Exercise-tool" (VOdEX-tool), a graphical user interface that allows automate calculation of EOV. A Discrete Meyer Level 2 wavelet transformation appeared to be the optimal filter to apply on the collected breath-by-breath minute ventilation CPET data. Divers aspects of the definitions i.e. cycle length, amplitude, regularity and total duration of EOV were combined and calculated. The oscillations meeting the criteria were visualised. Filter methods and cut-off criteria were made adjustable for clinical application and research. The VOdEX-tool was connected to a database. The VOdEX-tool provides the possibility to calculate EOV automatically and to present the clinician an overview of the presence of EOV at a glance. The computerized analysis of EOV can be made readily available in clinical practice by integrating the tool in the manufactures existing CPET software. The VOdEX-tool enhances assessment of EOV and therefore contributes to the estimation of prognosis in especially patients with HF. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Using dimers to measure biosignatures and atmospheric pressure for terrestrial exoplanets.
Misra, Amit; Meadows, Victoria; Claire, Mark; Crisp, Dave
2014-02-01
We present a new method to probe atmospheric pressure on Earth-like planets using (O2-O2) dimers in the near-infrared. We also show that dimer features could be the most readily detectable biosignatures for Earth-like atmospheres and may even be detectable in transit transmission with the James Webb Space Telescope (JWST). The absorption by dimers changes more rapidly with pressure and density than that of monomers and can therefore provide additional information about atmospheric pressures. By comparing the absorption strengths of rotational and vibrational features to the absorption strengths of dimer features, we show that in some cases it may be possible to estimate the pressure at the reflecting surface of a planet. This method is demonstrated by using the O2 A band and the 1.06 μm dimer feature, either in transmission or reflected spectra. It works best for planets around M dwarfs with atmospheric pressures between 0.1 and 10 bar and for O2 volume mixing ratios above 50% of Earth's present-day level. Furthermore, unlike observations of Rayleigh scattering, this method can be used at wavelengths longer than 0.6 μm and is therefore potentially applicable, although challenging, to near-term planet characterization missions such as JWST. We also performed detectability studies for JWST transit transmission spectroscopy and found that the 1.06 and 1.27 μm dimer features could be detectable (SNR>3) for an Earth analogue orbiting an M5V star at a distance of 5 pc. The detection of these features could provide a constraint on the atmospheric pressure of an exoplanet and serve as biosignatures for oxygenic photosynthesis. We calculated the required signal-to-noise ratios to detect and characterize O2 monomer and dimer features in direct imaging-reflected spectra and found that signal-to-noise ratios greater than 10 at a spectral resolving power of R=100 would be required.
Mung, Dorothea; Li, Liang
2018-02-25
There is an increasing demand for donor human milk to feed infants for various reasons including that a mother may be unable to provide sufficient amounts of milk for their child or the milk is considered unsafe for the baby. Selling and buying human milk via the Internet has gained popularity. However, there is a risk of human milk sold containing other adulterants such as animal or plant milk. Analytical tools for rapid detection of adulterants in human milk are needed. We report a quantitative metabolomics method for detecting potential milk adulterants (soy, almond, cow, goat and infant formula milk) in human milk. It is based on the use of a high-performance chemical isotope labeling (CIL) LC-MS platform to profile the metabolome of an unknown milk sample, followed by multivariate or univariate comparison of the resultant metabolomic profile with that of human milk to determine the differences. Using dansylation LC-MS to profile the amine/phenol submetabolome, we could detect an average of 4129 ± 297 (n = 9) soy metabolites, 3080 ± 470 (n = 9) almond metabolites, 4256 ± 136 (n = 18) cow metabolites, 4318 ± 198 (n = 9) goat metabolites, 4444 ± 563 (n = 9) infant formula metabolites, and 4020 ± 375 (n = 30) human metabolites. This high level of coverage allowed us to readily differentiate the six different types of samples. From the analysis of binary mixtures of human milk containing 5, 10, 25, 50 and 75% other type of milk, we demonstrated that this method could be used to detect the presence of as low as 5% adulterant in human milk. We envisage that this method could be applied to detect contaminant or adulterant in other types of food or drinks. Copyright © 2017 Elsevier B.V. All rights reserved.
"Development of Model-Based Air Pollution Exposure Metrics for use in Epidemiologic Studies"
Population-based epidemiological studies of air pollution have traditionally relied upon imperfect surrogates of personal exposures, such as area-wide ambient air pollution levels based on readily available concentrations from central monitoring sites. U.S. EPA in collaboration w...
DEVELOPMENT OF MODEL-BASED AIR POLLUTION EXPOSURE METRICS FOR USE IN EPIDEMIOLOGIC STUDIES
Population-based epidemiological studies of air pollution have traditionally relied upon imperfect surrogates of personal exposures, such as area-wide ambient air pollution levels based on readily available concentrations from central monitoring sites. U.S. EPA in collaboration w...
Interactive Tax Reform: Simulating Impacts of Legislative Proposals.
ERIC Educational Resources Information Center
Downing, Roger H.; And Others
1985-01-01
Pennsylvania's mathematical modeling technique to evaluate tax reform proposals requires the following data: personal income at the local level and measures of the breakdown of property tax payment by land use classification. The simulation technique could be readily adapted in reorganizing educational finance systems. (MLF)
High levels of heterozygosity found for 15 SSR loci in Solanum chacoense
USDA-ARS?s Scientific Manuscript database
Genetic variation is a necessary prerequisite for improving domesticated plants through breeding; without it, breeding progress would be impossible. Genetic variation can be readily ascertained with co-dominant DNA markers, such as simple sequence repeats (SSRs). Twenty-four SSR markers specifically...
Many utilities are seeking innovative rehabilitation technologies to extend the life and fix larger portions of their water distribution systems with current funding levels. The information on the capabilities and applicability of new technologies is not always readily available...
Advanced Decision-Support for Coastal Beach Health: Virtual Beach 3.0
Virtual Beach is a free decision-support system designed to help beach managers and researchers construct, evaluate, and operate site-specific statistical models that can predict levels of fecal indicator bacteria (FIB) based on environmental conditions that are more readily mea...
Facile patterning of hybrid CdSe nanoparticle films by photoinduced surface defects.
Park, Yushin; Felipe, Mary Jane; Advincula, Rigoberto C
2011-11-01
The photopatterning of CdSe quantum dots (QDs) films is facilitated by preparing defect-rich QDs on selective sites on the film. A key step is UV irradiation in the presence of a polar solvent such as methanol in situ as a "developer" which readily dissolves trioctylphosphine oxide (TOPO) but not the QDs. This results in a dramatically reduced photopatterning time and irradiation intensity requirement. The optical property changes were examined by UV-vis and fluorescence spectroscopy. Furthermore, the photo-oxidized pattern of the CdSe QD film was readily observed by fluorescence microscopy. The chemical change due to attenuation of the P═O vibration of TOPO (due to its removal) could be detected by FT-IR imaging or FT-IR chemical mapping. Thus, the protocol is a simple yet effective way of patterning PL properties of QD films at much reduced exposure time compared to previously reported methods. It may find utility for a host of cell-based film assays and PL display device applications at various resolutions.
Digital implementation of a neural network for imaging
NASA Astrophysics Data System (ADS)
Wood, Richard; McGlashan, Alex; Yatulis, Jay; Mascher, Peter; Bruce, Ian
2012-10-01
This paper outlines the design and testing of a digital imaging system that utilizes an artificial neural network with unsupervised and supervised learning to convert streaming input (real time) image space into parameter space. The primary objective of this work is to investigate the effectiveness of using a neural network to significantly reduce the information density of streaming images so that objects can be readily identified by a limited set of primary parameters and act as an enhanced human machine interface (HMI). Many applications are envisioned including use in biomedical imaging, anomaly detection and as an assistive device for the visually impaired. A digital circuit was designed and tested using a Field Programmable Gate Array (FPGA) and an off the shelf digital camera. Our results indicate that the networks can be readily trained when subject to limited sets of objects such as the alphabet. We can also separate limited object sets with rotational and positional invariance. The results also show that limited visual fields form with only local connectivity.
Near infrared spectroscopy for fibre based gas detection
NASA Astrophysics Data System (ADS)
Stewart, George; Johnstone, Walter; Thursby, Graham; Culshaw, Brian
2010-04-01
Gas sensing systems based on fibre optic linked near infra red absorption cells are potentially a flexible and effective tool for monitoring accumulations of hazardous and noxious gases in enclosed areas such as tunnels and mines. Additionally the same baseline technology is readily modified to measure concentrations of hydrocarbon fuels - notably but not exclusively methane, and monitoring emissions of greenhouse gases. Furthermore the system can be readily implemented to provide intrinsically safe monitoring over extensive areas at up to ~250 points from a single interrogation unit. In this paper we review our work on fibre coupled gas sensing systems. We outline the basic principles through which repeatable and accurate self calibrating gas measurements may be realised, including the recover of detailed line shapes for non contact temperature and / or pressure measurements in addition to concentration assessments in harsh environments. We also outline our experience in using these systems in extensive networks operating under inhospitable conditions over extended periods extending to several years.
Reconstructing Ion Spectra from Low-Altitude ENAs: Moderate to Large Storms.
NASA Astrophysics Data System (ADS)
LLera, K.; Goldstein, J.; McComas, D. J.; Valek, P. W.
2015-12-01
Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS) Energetic neutral atom (ENA) imagers regularly observe Low-altitude Emission (LAE) intensifications during geomagnetic storm intervals. Since LAEs are produced by the interaction between ions and the near-Earth exosphere (altitudes ~200-800 km), they are a global signature of how the ring current decays in response to solar wind conditions. In this "optically thick" region, an ENA readily becomes reionized, and an ion is readily neutralized. Therefore, emerging ENAs that contribute to the LAE signal (detectable several RE away) have undergone multiple charge exchange and electron stripping interactions. Accounting for the ~36 eV energy loss per interaction, we developed a model to quantify the total energy lost by emergent LAEs. The analytical tool is applied to an ensemble of moderate to large storms (including the recent 17 March and 23 June storms in 2015) to reconstruct the parent ion spectra from TWINS ENA images. We examine the ion spectra energy characteristics among the various storm events.
Detection of alkali-silica reaction swelling in concrete by staining
Guthrie, G.D. Jr.; Carey, J.W.
1998-04-14
A method using concentrated aqueous solutions of sodium cobalt nitrite and rhodamine B is described which can be used to identify concrete that contains gels formed by the alkali-silica reaction (ASR). These solutions present little health or environmental risk, are readily applied, and rapidly discriminate between two chemically distinct gels; K-rich, Na-K-Ca-Si gels are identified by yellow staining, and alkali-poor, Ca-Si gels are identified by pink staining.
Isolation of carbohydrate-metabolizing, extremely halophilic bacteria.
NASA Technical Reports Server (NTRS)
Tomlinson, G. A.; Hochstein, L. I.
1972-01-01
Four previously unrecognized strains of extremely halophilic bacteria that utilize carbohydrates have been isolated. Gas production proved an unreliable index of carbohydrate metabolism; therefore, carbohydrate utilization was measured by determining acid formation and sugar disappearance during growth. By these procedures, carbohydrate utilization was readily detected. The results suggest that carbohydrate dissimilation by extremely halophilic bacteria may be more common than previously thought and that the apparent rarity of carbohydrate-metabolizing halophiles may be an artifact of the isolation procedures used.
Optical Power Limiting Liquid Crystal Composites
1994-11-10
essentially a measurement of self -focusing by the sample; the nonlinear refractive index of the sample can be readily determined from intensity of the...transmitted ligse is detected th e tw o trasmted eetofteirtpulses have he the samst respose regardlessd, the sapeostnrltieton thle f"creints This implies that...these materials on the nanosecond time regime has also been observed. In Fig. 19 we show the OPL respose of a 25 pm thick sample of i nematic 5CB
[Value of x-ray computed tomography in the study of the inferior vena cava in urologic practice].
Barré, C; Vialle, M; Rieux, D; Caron-Poitreau, C; Soret, J Y; Rognon, M
1985-01-01
The CT scan provides a reliable evaluation of the inferior vena cava, especially since the development of second and third generation scanners. It can readily detect congenital malformations and obstructive anomalies complicating renal cancer and it is also able to determine the tumoral or thrombotic nature of the venous obstruction. This excellent definition of the vessel reduces the indications for caval angiography to a few exceptional cases.
1993-01-01
Effect of Methotrexate on Expression of Interceilular Adhesion Molecule I in Interleukin- 1 Stimulated Cultured Human Cells KEYWORDS: methotrexate...on interleukin- 1 ( IL -I) induced ICAM-l expression in cultured human fibroblasts and adenocarcinoma cells. TECHNICAL APPROACH Expression of ICAM- 1 will...incubated with IL -l to stimulate ICAM-l expression. In general, the cells responded well. ICAM- 1 was readily detectable with monoclonal antibodies and flow
Towards Development of a Field-Deployable Imaging Device for TBI
2012-03-01
centers such as in Germany for those studies, as well as additional medical care. This is because magnetic resonance imaging is unavailable in or near...detection of stroke in areas 283 where CAT scans and magnetic resonance imaging are not readily available or appropriate. 284 285 ACKNOWLEDGEMENTS...Task (3): MR image rodent brains. 3) UVA has performed its first round of MRI studies of CCI rats – Figures 1a,b,c. Task (4): Immunohistochemical
Renewable-reagent electrochemical sensor
Wang, Joseph; Olsen, Khris B.
1999-01-01
A new electrochemical probe(s) design allowing for continuous (renewable) reagent delivery. The probe comprises an integrated membrane-sampling/electrochemical sensor that prevents interferences from surface-active materials and greatly extends the linear range. The probe(s) is useful for remote or laboratory-based monitoring in connection with microdialysis sampling and electrochemical measurements of metals and organic compounds that are not readily detected in the absence of reacting with the compound. Also disclosed is a method of using the probe(s).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burrage, Clare; Copeland, Edmund J.; Hinds, E.A., E-mail: Clare.Burrage@nottingham.ac.uk, E-mail: Edmund.Copeland@nottingham.ac.uk, E-mail: Ed.Hinds@imperial.ac.uk
Theories of dark energy require a screening mechanism to explain why the associated scalar fields do not mediate observable long range fifth forces. The archetype of this is the chameleon field. Here we show that individual atoms are too small to screen the chameleon field inside a large high-vacuum chamber, and therefore can detect the field with high sensitivity. We derive new limits on the chameleon parameters from existing experiments, and show that most of the remaining chameleon parameter space is readily accessible using atom interferometry.
The potential of pigeons as surrogate observers in medical image perception studies
NASA Astrophysics Data System (ADS)
Krupinski, Elizabeth A.; Levenson, Richard M.; Navarro, Victor; Wasserman, Edward A.
2016-03-01
Assessment of medical image quality and how changes in image appearance impact performance are critical but assessment can be expensive and time-consuming. Could an animal (pigeon) observer with well-known visual skills and documented ability to distinguish complex visual stimuli serve as a surrogate for the human observer? Using sets of whole slide pathology (WSI) and mammographic images we trained pigeons (cohorts of 4) to detect and/or classify lesions in medical images. Standard training methods were used. A chamber equipped with a 15' display with a resistive touchscreen was used to display the images and record responses (pecks). Pigeon pellets were dispensed for correct responses. The pigeons readily learned to distinguish benign from malignant breast cancer histopathology in WSI (mean % correct responses rose 50% to 85% over 15 days) and generalized readily from 4X to 10X and 20X magnifications; to detect microcalcifications (mean % correct responses rose 50% to over 85% over 25 days); to distinguish benign from malignant breast masses (3 of 4 birds learned this task to around 80% and 60% over 10 days); and ignore compression artifacts in WSI (performance with uncompressed slides averaged 95% correct; 15:1 and 27:1 compression slides averaged 92% and 90% correct). Pigeons models may help us better understand medical image perception and may be useful in quality assessment by serving as surrogate observers for certain types of studies.
2017-01-01
An ultraefficient cap-exchange protocol (UCEP) that can convert hydrophobic quantum dots (QDs) into stable, biocompatible, and aggregation-free water-dispersed ones at a ligand:QD molar ratio (LQMR) as low as 500, some 20–200-fold less than most literature methods, has been developed. The UCEP works conveniently with air-stable lipoic acid (LA)-based ligands by exploiting tris(2-carboxylethyl phosphine)-based rapid in situ reduction. The resulting QDs are compact (hydrodynamic radius, Rh, < 4.5 nm) and bright (retaining > 90% of original fluorescence), resist nonspecific adsorption of proteins, and display good stability in biological buffers even with high salt content (e.g., 2 M NaCl). These advantageous properties make them well suited for cellular imaging and ratiometric biosensing applications. The QDs prepared by UCEP using dihydrolipoic acid (DHLA)-zwitterion ligand can be readily conjugated with octa-histidine (His8)-tagged antibody mimetic proteins (known as Affimers). These QDs allow rapid, ratiometric detection of the Affimer target protein down to 10 pM via a QD-sensitized Förster resonance energy transfer (FRET) readout signal. Moreover, compact biotinylated QDs can be readily prepared by UCEP in a facile, one-step process. The resulting QDs have been further employed for ratiometric detection of protein, exemplified by neutravidin, down to 5 pM, as well as for fluorescence imaging of target cancer cells. PMID:28421739
NASA Astrophysics Data System (ADS)
Lau, Han Yih; Wu, Haoqi; Wee, Eugene J. H.; Trau, Matt; Wang, Yuling; Botella, Jose R.
2017-01-01
Developing quick and sensitive molecular diagnostics for plant pathogen detection is challenging. Herein, a nanoparticle based electrochemical biosensor was developed for rapid and sensitive detection of plant pathogen DNA on disposable screen-printed carbon electrodes. This 60 min assay relied on the rapid isothermal amplification of target pathogen DNA sequences by recombinase polymerase amplification (RPA) followed by gold nanoparticle-based electrochemical assessment with differential pulse voltammetry (DPV). Our method was 10,000 times more sensitive than conventional polymerase chain reaction (PCR)/gel electrophoresis and could readily identify P. syringae infected plant samples even before the disease symptoms were visible. On the basis of the speed, sensitivity, simplicity and portability of the approach, we believe the method has potential as a rapid disease management solution for applications in agriculture diagnostics.
Lau, Han Yih; Wu, Haoqi; Wee, Eugene J H; Trau, Matt; Wang, Yuling; Botella, Jose R
2017-01-17
Developing quick and sensitive molecular diagnostics for plant pathogen detection is challenging. Herein, a nanoparticle based electrochemical biosensor was developed for rapid and sensitive detection of plant pathogen DNA on disposable screen-printed carbon electrodes. This 60 min assay relied on the rapid isothermal amplification of target pathogen DNA sequences by recombinase polymerase amplification (RPA) followed by gold nanoparticle-based electrochemical assessment with differential pulse voltammetry (DPV). Our method was 10,000 times more sensitive than conventional polymerase chain reaction (PCR)/gel electrophoresis and could readily identify P. syringae infected plant samples even before the disease symptoms were visible. On the basis of the speed, sensitivity, simplicity and portability of the approach, we believe the method has potential as a rapid disease management solution for applications in agriculture diagnostics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hara, T.; Jung, L.K.L.; FU, S.M.
1986-03-01
With human T cells activated for 12 hours by 12-o-tetradecanoyl phorbol-13-acetate (TPA) as immunogen, an IgG/sub 2a/ monoclonal antibody, mAb Ea 1, has been generated to a 60KD phosphorylated protein with 32KD and 28KD subunits. The antigen, Ea 1, is readily detected on 60% of isolated thymocytes by indirect immunofluorescence. A low level of Ea 1 expression is detectable on 2-6% of blood lymphocytes. Isolated T cells have been induced to express Ea 1 by TPA, mitogens and anitgens. TPA activated T cells express Ea 1 as early as 1 hour after activation. By 4 hours, greater than 95% ofmore » the T cells stain with mAb Ea 1. About 50% of the PHA or Con A activated T cells express Ea 1 with a similar kinetics. Ea 1 expression proceeds that of IL-2 receptor in these activation processes. T cells activated by soluble antigens (tetanus toxoid and PPD) and alloantigens in MLR also express Ea 1 after a long incubation. About 20% of the T cells stain for Ea 1 at day 6. Ea 1 expression is not limited to activated T cells. B cells activated by TPA or anti-IgM Ab plus B cell growth factor express Ea 1. The kinetics of Ea 1 expression is slower and the staining is less intense. Repeated attempts to detect Ea 1 on resting and activated monocytes and granulocytes have not been successful. Ea 1 expression is due to de novo synthesis for its induction is blocked by cycloheximide and actinomycin D. Ea 1 is the earliest activation antigen detectable to-date.« less
NASA Astrophysics Data System (ADS)
Ye, Xiang; Gao, Weihua; Yan, Yanjun; Osadciw, Lisa A.
2010-04-01
Wind is an important renewable energy source. The energy and economic return from building wind farms justify the expensive investments in doing so. However, without an effective monitoring system, underperforming or faulty turbines will cause a huge loss in revenue. Early detection of such failures help prevent these undesired working conditions. We develop three tests on power curve, rotor speed curve, pitch angle curve of individual turbine. In each test, multiple states are defined to distinguish different working conditions, including complete shut-downs, under-performing states, abnormally frequent default states, as well as normal working states. These three tests are combined to reach a final conclusion, which is more effective than any single test. Through extensive data mining of historical data and verification from farm operators, some state combinations are discovered to be strong indicators of spindle failures, lightning strikes, anemometer faults, etc, for fault detection. In each individual test, and in the score fusion of these tests, we apply multidimensional scaling (MDS) to reduce the high dimensional feature space into a 3-dimensional visualization, from which it is easier to discover turbine working information. This approach gains a qualitative understanding of turbine performance status to detect faults, and also provides explanations on what has happened for detailed diagnostics. The state-of-the-art SCADA (Supervisory Control And Data Acquisition) system in industry can only answer the question whether there are abnormal working states, and our evaluation of multiple states in multiple tests is also promising for diagnostics. In the future, these tests can be readily incorporated in a Bayesian network for intelligent analysis and decision support.
Characterizing volcanic activity: Application of freely-available webcams
NASA Astrophysics Data System (ADS)
Dehn, J.; Harrild, M.; Webley, P. W.
2017-12-01
In recent years, freely-available web-based cameras, or webcams, have become more readily available allowing an increased level of monitoring at active volcanoes across the globe. While these cameras have been extensively used as qualitative tools, they provide a unique dataset to perform quantitative analyzes of the changing behavior of the particular volcano within the cameras field of view. We focus on the multitude of these freely-available webcams and present a new algorithm to detect changes in volcanic activity using nighttime webcam data. Our approach uses a quick, efficient, and fully automated algorithm to identify changes in webcam data in near real-time, including techniques such as edge detection, Gaussian mixture models, and temporal/spatial statistical tests, which are applied to each target image. Often the image metadata (exposure, gain settings, aperture, focal length, etc.) are unknown, meaning we developed our algorithm to identify the quantity of volcanically incandescent pixels as well as the number of specific algorithm tests needed to detect thermal activity, instead of directly correlating brightness in the webcam to eruption temperatures. We compared our algorithm results to a manual analysis of webcam data for several volcanoes and determined a false detection rate of less than 3% for the automated approach. In our presentation, we describe the different tests integrated into our algorithm, lessons learned, and how we applied our method to several volcanoes across the North Pacific during its development and implementation. We will finish with a discussion on the global applicability of our approach and how to build a 24/7, 365 day a year tool that can be used as an additional data source for real-time analysis of volcanic activity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, T.; Tai, C.L.; Taylor, D.G.
1989-02-01
Detomidine is a potent non-narcotic sedative agent which is currently in the process of being approved for veterinary clinical use in the United States. Since no effective screening method in horses is available for detomidine, we have developed an /sup 125/I radioimmunoassay for detomidine in equine blood and urine as part of a panel of tests for illegal drugs in performance horses. Our /sup 125/I radioimmunoassay has an I-50 for detomidine of approximately 2 ng/ml. Our assay shows limited cross-reactivity with the pharmacodynamically similar xylazine, but does not cross-react with acepromazine, epinephrine, haloperidol or promazine. The plasma kinetic data frommore » clinical (greater than or equal to 5 mg/horse) as well as sub-clinical doses indicate first-order elimination in a dose-dependent manner. Within the first 30 minutes after intravenous (IV) administration of 30 mg/horse, plasma levels peak at approximately 20 ng/ml and then decline with an apparent plasma half-life of 25 minutes. Diuresis can occur with administration of clinical doses of detomidine and this effect was accounted for in the analysis of urine samples. Using this method, administration of 30 mg/horse can be readily detected in equine urine for up to 8 hours after IV injection. Additionally, doses as low as 0.5 mg/horse can be detected for short periods of time in blood and urine with use of this assay. Utilization of this assay by research scientists and forensic analysts will allow for the establishment of proper guidelines and controls regarding detomidine administration to performance horses and assurance of compliance with these guidelines.« less
Fiedler, Klaus; Kareev, Yaakov; Avrahami, Judith; Beier, Susanne; Kutzner, Florian; Hütter, Mandy
2016-01-01
Detecting changes, in performance, sales, markets, risks, social relations, or public opinions, constitutes an important adaptive function. In a sequential paradigm devised to investigate detection of change, every trial provides a sample of binary outcomes (e.g., correct vs. incorrect student responses). Participants have to decide whether the proportion of a focal feature (e.g., correct responses) in the population from which the sample is drawn has decreased, remained constant, or increased. Strong and persistent anomalies in change detection arise when changes in proportional quantities vary orthogonally to changes in absolute sample size. Proportional increases are readily detected and nonchanges are erroneously perceived as increases when absolute sample size increases. Conversely, decreasing sample size facilitates the correct detection of proportional decreases and the erroneous perception of nonchanges as decreases. These anomalies are however confined to experienced samples of elementary raw events from which proportions have to be inferred inductively. They disappear when sample proportions are described as percentages in a normalized probability format. To explain these challenging findings, it is essential to understand the inductive-learning constraints imposed on decisions from experience.
Tracking serum antibody response to viral antigens with arrayed imaging reflectometry
NASA Astrophysics Data System (ADS)
Mace, Charles R.; Rose, Robert C.; Miller, Benjamin L.
2009-02-01
Arrayed Imaging Reflectometry, or "AIR", is a new label-free technique for detecting proteins that relies on bindinginduced changes in the response of an antireflective coating on the surface of a silicon ship. Because the technique provides high sensitivity, excellent dynamic range, and readily integrates with standard silicon wafer processing technology, it is an exceptionally attractive platform on which to build systems for detecting proteins in complex solutions. In our early research, we used AIR chips bearing secreted receptor proteins from enteropathogenic E. coli to develop sensors for this pathogen. Recently, we have been exploring an alternative strategy: Rather than detecting the pathogen directly, can one immobilize antigens from a pathogen, and employ AIR to detect antibody responses to those antigens? Such a strategy would provide enhanced sensitivity for pathogen detection (as the immune system essentially amplifies the "signal" caused by the presence of an organism to which it responds), and would also potentially prove useful in the process of vaccine development. We describe herein preliminary results in the application of such a strategy to the detection of antibodies to human papillomavirus (HPV).
NASA Astrophysics Data System (ADS)
Bichler, Andrea; Neumaier, Arnold; Hofmann, Thilo
2014-11-01
Microbial contamination of groundwater used for drinking water can affect public health and is of major concern to local water authorities and water suppliers. Potential hazards need to be identified in order to protect raw water resources. We propose a non-parametric data mining technique for exploring the presence of total coliforms (TC) in a groundwater abstraction well and its relationship to readily available, continuous time series of hydrometric monitoring parameters (seven year records of precipitation, river water levels, and groundwater heads). The original monitoring parameters were used to create an extensive generic dataset of explanatory variables by considering different accumulation or averaging periods, as well as temporal offsets of the explanatory variables. A classification tree based on the Chi-Squared Automatic Interaction Detection (CHAID) recursive partitioning algorithm revealed statistically significant relationships between precipitation and the presence of TC in both a production well and a nearby monitoring well. Different secondary explanatory variables were identified for the two wells. Elevated water levels and short-term water table fluctuations in the nearby river were found to be associated with TC in the observation well. The presence of TC in the production well was found to relate to elevated groundwater heads and fluctuations in groundwater levels. The generic variables created proved useful for increasing significance levels. The tree-based model was used to predict the occurrence of TC on the basis of hydrometric variables.
Anderson, J.E.; Ducey, Mark J.; Fast, A.; Martin, M.E.; Lepine, L.; Smith, M.-L.; Lee, T.D.; Dubayah, R.O.; Hofton, M.A.; Hyde, P.; Peterson, Birgit; Blair, J.B.
2011-01-01
Waveform lidar imagery was acquired on September 26, 1999 over the Bartlett Experimental Forest (BEF) in New Hampshire (USA) using NASA's Laser Vegetation Imaging Sensor (LVIS). This flight occurred 20 months after an ice storm damaged millions of hectares of forestland in northeastern North America. Lidar measurements of the amplitude and intensity of ground energy returns appeared to readily detect areas of moderate to severe ice storm damage associated with the worst damage. Southern through eastern aspects on side slopes were particularly susceptible to higher levels of damage, in large part overlapping tracts of forest that had suffered the highest levels of wind damage from the 1938 hurricane and containing the highest levels of sugar maple basal area and biomass. The levels of sugar maple abundance were determined through analysis of the 1997 Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) high resolution spectral imagery and inventory of USFS Northern Research Station field plots. We found a relationship between field measurements of stem volume losses and the LVIS metric of mean canopy height (r2 = 0.66; root mean square errors = 5.7 m3/ha, p < 0.0001) in areas that had been subjected to moderate-to-severe ice storm damage, accurately documenting the short-term outcome of a single disturbance event.
High-Level Data-Abstraction System
NASA Technical Reports Server (NTRS)
Fishwick, P. A.
1986-01-01
Communication with data-base processor flexible and efficient. High Level Data Abstraction (HILDA) system is three-layer system supporting data-abstraction features of Intel data-base processor (DBP). Purpose of HILDA establishment of flexible method of efficiently communicating with DBP. Power of HILDA lies in its extensibility with regard to syntax and semantic changes. HILDA's high-level query language readily modified. Offers powerful potential to computer sites where DBP attached to DEC VAX-series computer. HILDA system written in Pascal and FORTRAN 77 for interactive execution.
NASA Astrophysics Data System (ADS)
Miller, Steven D.; Bankert, Richard L.; Solbrig, Jeremy E.; Forsythe, John M.; Noh, Yoo-Jeong; Grasso, Lewis D.
2017-12-01
This paper describes a Dynamic Enhancement Background Reduction Algorithm (DEBRA) applicable to multispectral satellite imaging radiometers. DEBRA uses ancillary information about the clear-sky background to reduce false detections of atmospheric parameters in complex scenes. Applied here to the detection of lofted dust, DEBRA enlists a surface emissivity database coupled with a climatological database of surface temperature to approximate the clear-sky equivalent signal for selected infrared-based multispectral dust detection tests. This background allows for suppression of false alarms caused by land surface features while retaining some ability to detect dust above those problematic surfaces. The algorithm is applicable to both day and nighttime observations and enables weighted combinations of dust detection tests. The results are provided quantitatively, as a detection confidence factor [0, 1], but are also readily visualized as enhanced imagery. Utilizing the DEBRA confidence factor as a scaling factor in false color red/green/blue imagery enables depiction of the targeted parameter in the context of the local meteorology and topography. In this way, the method holds utility to both automated clients and human analysts alike. Examples of DEBRA performance from notable dust storms and comparisons against other detection methods and independent observations are presented.
MERGANSER- Predicting Mercury Levels in Fish and Loons in New England Lakes
MERGANSER (MERcury Geo-spatial AssesmentS for the New England Region) is an empirical least squares multiple regression model using atmospheric deposition of mercury (Hg) and readily obtainable lake and watershed features to predict fish and common loon Hg (as methyl mercury) in ...
Population-based epidemiologic studies of air pollution have traditionally relied upon imperfect surrogates of personal exposures, such as area-wide ambient air pollution levels based on readily available outdoor concentrations from central monitoring sites. This practice may in...
Probing the location of displayed cytochrome b562 on amyloid by scanning tunnelling microscopy
NASA Astrophysics Data System (ADS)
Forman, C. J.; Wang, N.; Yang, Z. Y.; Mowat, C. G.; Jarvis, S.; Durkan, C.; Barker, P. D.
2013-05-01
Amyloid fibres displaying cytochrome b562 were probed using scanning tunnelling microscopy (STM) in vacuo. The cytochromes are electron transfer proteins containing a haem cofactor and could, in principle, mediate electron transfer between the tip and the gold substrate. If the core fibres were insulating and electron transfer within the 3D haem network was detected, then the electron transport properties of the fibre could be controlled by genetic engineering. Three kinds of STM images were obtained. At a low bias (<1.5 V) the fibres appeared as regions of low conductivity with no evidence of cytochrome mediated electron transfer. At a high bias, stable peaks in tunnelling current were observed for all three fibre species containing haem and one species of fibre that did not contain haem. In images of this kind, some of the current peaks were collinear and spaced around 10 nm apart over ranges longer than 100 nm, but background monomers complicate interpretation. Images of the third kind were rare (1 in 150 fibres); in these, fully conducting structures with the approximate dimensions of fibres were observed, suggesting the possibility of an intermittent conduction mechanism, for which a precedent exists in DNA. To test the conductivity, some fibres were immobilized with sputtered gold, and no evidence of conduction between the grains of gold was seen. In control experiments, a variation of monomeric cytochrome b562 was not detected by STM, which was attributed to low adhesion, whereas a monomeric multi-haem protein, GSU1996, was readily imaged. We conclude that the fibre superstructure may be intermittently conducting, that the cytochromes have been seen within the fibres and that they are too far apart for detectable current flow between sites to occur. We predict that GSU1996, being 10 nm long, is more likely to mediate successful electron transfer along the fibre as well as being more readily detectable when displayed from amyloid.
Sänger, Philipp Wilhelm; Freesmeyer, Martin
2016-06-01
Whole-body PET with Ga-DOTA-D-Phe-Tyr-octreotide (Ga-DOTATOC) and contrast-enhanced CT (ceCT) are considered a standard for the staging of neuroendocrine tumors (NETs). This study sought to verify whether early dynamic (ed) Ga-DOTATOC PET/CT can reliably detect liver metastases of NETs (hypervascular, nonhypervascular; positive or negative for somatostatin receptors) and to verify if the receptor positivity has a significant impact on the detection of tumor hypervascularization. Twenty-seven patients with NET were studied by ceCT and standard whole-body PET according to established Ga-DOTATOC protocols. In addition, edPET data were obtained by continuous scanning during the first 300 seconds after bolus injections of the radiotracer. Early dynamic PET required an additional low-dose, native CT image of the liver for the purpose of attenuation correction. Time-activity and time-contrast curves were obtained, the latter being calculated by the difference between tumor and reference regions. Early dynamic PET/CT proved comparable with ceCT in readily identifying hypervascular lesions, irrespective of the receptor status, with activities rising within 16 to 40 seconds. Early dynamic PET/CT also readily identified nonhypervascular, receptor-positive lesions. Positive image contrasts were obtained for hypervascular, receptor-positive lesions, whereas early negative contrasts were obtained for nonhypervascular, receptor-negative lesions. The high image contrast of hypervascular NET metastases in early arterial phases suggests that edPET/CT can become a useful alternative in patients with contraindications to ceCT. The high density of somatostatin receptors did not seem to interfere with the detection of the lesion's hypervascularization.
Food-chain contamination evaluations in ecological risk assessments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linder, G.
Food-chain models have become increasingly important within the ecological risk assessment process. This is the case particularly when acute effects are not readily apparent, or the contaminants of concern are not readily detoxified, have a high likelihood for partitioning into lipids, or have specific target organs or tissues that may increase their significance in evaluating their potential adverse effects. An overview of food-chain models -- conceptual, theoretical, and empirical -- will be considered through a series of papers that will focus on their application within the ecological risk assessment process. Whether a food-chain evaluation is being developed to address relativelymore » simple questions related to chronic effects of toxicants on target populations, or whether a more complex food-web model is being developed to address questions related to multiple-trophic level transfers of toxicants, the elements within the food chain contamination evaluation can be generalized to address the mechanisms of toxicant accumulation in individual organisms. This can then be incorporated into more elaborate models that consider these organismal-level processes within the context of a species life-history or community-level responses that may be associated with long-term exposures.« less
Bedrossian, Manuel; Lindensmith, Chris
2017-01-01
Abstract Detection of extant microbial life on Earth and elsewhere in the Solar System requires the ability to identify and enumerate micrometer-scale, essentially featureless cells. On Earth, bacteria are usually enumerated by culture plating or epifluorescence microscopy. Culture plates require long incubation times and can only count culturable strains, and epifluorescence microscopy requires extensive staining and concentration of the sample and instrumentation that is not readily miniaturized for space. Digital holographic microscopy (DHM) represents an alternative technique with no moving parts and higher throughput than traditional microscopy, making it potentially useful in space for detection of extant microorganisms provided that sufficient numbers of cells can be collected. Because sample collection is expected to be the limiting factor for space missions, especially to outer planets, it is important to quantify the limits of detection of any proposed technique for extant life detection. Here we use both laboratory and field samples to measure the limits of detection of an off-axis digital holographic microscope (DHM). A statistical model is used to estimate any instrument's probability of detection at various bacterial concentrations based on the optical performance characteristics of the instrument, as well as estimate the confidence interval of detection. This statistical model agrees well with the limit of detection of 103 cells/mL that was found experimentally with laboratory samples. In environmental samples, active cells were immediately evident at concentrations of 104 cells/mL. Published estimates of cell densities for Enceladus plumes yield up to 104 cells/mL, which are well within the off-axis DHM's limits of detection to confidence intervals greater than or equal to 95%, assuming sufficient sample volumes can be collected. The quantitative phase imaging provided by DHM allowed minerals to be distinguished from cells. Off-axis DHM's ability for rapid low-level bacterial detection and counting shows its viability as a technique for detection of extant microbial life provided that the cells can be captured intact and delivered to the sample chamber in a sufficient volume of liquid for imaging. Key Words: In situ life detection—Extant microorganisms—Holographic microscopy—Ocean Worlds—Enceladus—Imaging. Astrobiology 17, 913–925. PMID:28708412
Assessment of Myeloperoxidase Activity by the Conversion of Hydroethidine to 2-Chloroethidium*
Maghzal, Ghassan J.; Cergol, Katie M.; Shengule, Sudhir R.; Suarna, Cacang; Newington, Darren; Kettle, Anthony J.; Payne, Richard J.; Stocker, Roland
2014-01-01
Oxidants derived from myeloperoxidase (MPO) contribute to inflammatory diseases. In vivo MPO activity is commonly assessed by the accumulation of 3-chlorotyrosine (3-Cl-Tyr), although 3-Cl-Tyr is formed at low yield and is subject to metabolism. Here we show that MPO activity can be assessed using hydroethidine (HE), a probe commonly employed for the detection of superoxide. Using LC/MS/MS, 1H NMR, and two-dimensional NOESY, we identified 2-chloroethidium (2-Cl-E+) as a specific product when HE was exposed to hypochlorous acid (HOCl), chloramines, MPO/H2O2/chloride, and activated human neutrophils. The rate constant for HOCl-mediated conversion of HE to 2-Cl-E+ was estimated to be 1.5 × 105 m−1s−1. To investigate the utility of 2-Cl-E+ to assess MPO activity in vivo, HE was injected into wild-type and MPO-deficient (Mpo−/−) mice with established peritonitis or localized arterial inflammation, and tissue levels of 2-Cl-E+ and 3-Cl-Tyr were then determined by LC/MS/MS. In wild-type mice, 2-Cl-E+ and 3-Cl-Tyr were detected readily in the peritonitis model, whereas in the arterial inflammation model 2-Cl-E+ was present at comparatively lower concentrations (17 versus 0.3 pmol/mg of protein), and 3-Cl-Tyr could not be detected. Similar to the situation with 3-Cl-Tyr, tissue levels of 2-Cl-E+ were decreased substantially in Mpo−/− mice, indicative of the specificity of the assay. In the arterial inflammation model, 2-Cl-E+ was absent from non-inflamed arteries and blood, suggesting that HE oxidation occurred locally in the inflamed artery. Our data suggest that the conversion of exogenous HE to 2-Cl-E+ may be a useful selective and sensitive marker for MPO activity in addition to 3-Cl-Tyr. PMID:24436331
Li, Tiejun; Guo, Yuanming; Hu, Hongmei; Zhang, Xiaoning; Jin, Yanjian; Zhang, Xiaojun; Zhang, Yurong
2016-01-01
A simple, efficient, solvent-free, and commercial readily available approach for determination of five volatile chlorinated hydrocarbons in water samples using the static headspace sampling and gas chromatography with electron capture detection has been described. The proposed static headspace sampling method was initially optimized and the optimum experimental conditions found were 10 mL water sample containing 20% w/v sodium chloride placed in a 20 mL vial and stirred at 50ºC for 20 min. The linearity of the method was in the range of 1.2-240 μg/L for dichloromethane, 0.2-40 μg/L for trichloromethane, 0.005-1 μg/L for perchloromethane, 0.025-5 μg/L for trichloroethylene, and 0.01-2 μg/L for perchloroethylene, with coefficients of determination ranging between 0.9979 and 0.9990. The limits of detection were in the low μg/L level, ranging between 0.001 and 0.3 μg/L. The relative recoveries of spiked five volatile chlorinated hydrocarbons with external calibration method at different concentration levels in pure, tap, sea water of Jiaojiang Estuary, and sea water of waters of Xiaomendao were in the range of 91-116, 96-105, 86-112, and 80-111%, respectively, and with relative standard deviations of 1.9-3.6, 2.3-3.5, 1.5-2.7, and 2.3-3.7% (n = 5), respectively. The performance of the proposed method was compared with traditional liquid-liquid extraction on the real water samples (i.e., pure, tap, and sea water, etc.) and comparable efficiencies were obtained. It is concluded that this method can be successfully applied for the determination of volatile chlorinated hydrocarbons in different water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Detection And Mapping (DAM) package. Volume 4A: Software System Manual, part 1
NASA Technical Reports Server (NTRS)
Schlosser, E. H.
1980-01-01
The package is an integrated set of manual procedures, computer programs, and graphic devices designed for efficient production of precisely registered and formatted maps from digital LANDSAT multispectral scanner (MSS) data. The software can be readily implemented on any Univac 1100 series computer with standard peripheral equipment. This version of the software includes predefined spectral limits for use in classifying and mapping surface water for LANDSAT-1, LANDSAT-2, and LANDSAT-3. Tape formats supported include X, AM, and PM.
Potentiality for obtaining poria disease signatures in the Oregon Cascades from orbital altitudes
NASA Technical Reports Server (NTRS)
Wear, J. F.
1972-01-01
A prime photographic signature indicator of an important forest disease was identified in valuable Douglas-fir stands of the Pacific Northwest. The disease signature was verified by a multidisciplinary team of scientists to be the direct result of the Poria weirii root-rot syndrome in the Douglas-fir and hemlock stands of the high Cascades in Oregon. It is readily discernible on small-scale suborbital photography and has good potential for detection from earth-orbiting satellites or remote sensing platforms.
Monitoring arrangement for vented nuclear fuel elements
Campana, Robert J.
1981-01-01
In a nuclear fuel reactor core, fuel elements are arranged in a closely packed hexagonal configuration, each fuel element having diametrically opposed vents permitting 180.degree. rotation of the fuel elements to counteract bowing. A grid plate engages the fuel elements and forms passages for communicating sets of three, four or six individual vents with respective monitor lines in order to communicate vented radioactive gases from the fuel elements to suitable monitor means in a manner readily permitting detection of leakage in individual fuel elements.
Power and sample size for multivariate logistic modeling of unmatched case-control studies.
Gail, Mitchell H; Haneuse, Sebastien
2017-01-01
Sample size calculations are needed to design and assess the feasibility of case-control studies. Although such calculations are readily available for simple case-control designs and univariate analyses, there is limited theory and software for multivariate unconditional logistic analysis of case-control data. Here we outline the theory needed to detect scalar exposure effects or scalar interactions while controlling for other covariates in logistic regression. Both analytical and simulation methods are presented, together with links to the corresponding software.
Dynamical diffraction imaging (topography) with X-ray synchrotron radiation
NASA Technical Reports Server (NTRS)
Kuriyama, M.; Steiner, B. W.; Dobbyn, R. C.
1989-01-01
By contrast to electron microscopy, which yields information on the location of features in small regions of materials, X-ray diffraction imaging can portray minute deviations from perfect crystalline order over larger areas. Synchrotron radiation-based X-ray optics technology uses a highly parallel incident beam to eliminate ambiguities in the interpretation of image details; scattering phenomena previously unobserved are now readily detected. Synchrotron diffraction imaging renders high-resolution, real-time, in situ observations of materials under pertinent environmental conditions possible.
Postapocalypse stratigraphy: Some considerations and proposals
NASA Astrophysics Data System (ADS)
Prosh, E. C.; McCracken, A. D.
1985-01-01
An imminent nuclear apocalypse will be a geologically significant event characterized by widespread extinction and marked by a highly radioactive lower boundary layer. The concept of a fallout-enriched Cenozoic/postapocalypse boundary layer is significant in that such a horizon would constitute an ideal, global isochron that is both readily detectable and correlatable; the only other systemic boundary that appears to be analogous is the Cretaceous/Tertiary boundary. New terminology consistent with the established stratigraphic nomenclature is herein proposed for the major anticipated postapocalypse geochronologic units.
Deployable pressurized cell structure for a micrometeoroid detector
NASA Technical Reports Server (NTRS)
Kinard, W. H. (Inventor)
1974-01-01
This disclosure comprises a plurality of individual pressurized cells which are caused to leak in response to a micrometeoroid penetration, the leak being sensed by appropriate instrumentation. The plurality of cells may be rolled into a compact arrangement such that the volume of the micrometeoroid detector is small and therefore readily packed in a payload of a launch vehicle. Once the payload is placed in orbit, the rolled up cells can be released, pressurized and provide a relatively rigid, large surface area for detecting micrometeoroid penetration.
Entangled State Quantum Cryptography: Eavesdropping on the Ekert Protocol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naik, D. S.; Peterson, C. G.; White, A. G.
2000-05-15
Using polarization-entangled photons from spontaneous parametric down-conversion, we have implemented Ekert's quantum cryptography protocol. The near-perfect correlations of the photons allow the sharing of a secret key between two parties. The presence of an eavesdropper is continually checked by measuring Bell's inequalities. We investigated several possible eavesdropper strategies, including pseudo-quantum-nondemolition measurements. In all cases, the eavesdropper's presence was readily apparent. We discuss a procedure to increase her detectability. (c) 2000 The American Physical Society.
Renewable-reagent electrochemical sensor
Wang, J.; Olsen, K.B.
1999-08-24
A new electrochemical probe(s) design allowing for continuous (renewable) reagent delivery is described. The probe comprises an integrated membrane sampling/electrochemical sensor that prevents interferences from surface-active materials and greatly extends the linear range. The probe(s) is useful for remote or laboratory-based monitoring in connection with microdialysis sampling and electrochemical measurements of metals and organic compounds that are not readily detected in the absence of reacting with the compound. Also disclosed is a method of using the probe(s). 19 figs.
Probing dark energy with atom interferometry
NASA Astrophysics Data System (ADS)
Burrage, Clare; Copeland, Edmund J.; Hinds, E. A.
2015-03-01
Theories of dark energy require a screening mechanism to explain why the associated scalar fields do not mediate observable long range fifth forces. The archetype of this is the chameleon field. Here we show that individual atoms are too small to screen the chameleon field inside a large high-vacuum chamber, and therefore can detect the field with high sensitivity. We derive new limits on the chameleon parameters from existing experiments, and show that most of the remaining chameleon parameter space is readily accessible using atom interferometry.
Early recognition of serious infections in obstetrics and gynecology.
Soper, David E
2012-12-01
Pelvic infections commonly occur in pregnant and postoperative women. Most of these infections are readily diagnosed because of their typical clinical manifestations and prompt antimicrobial therapy that leads to the resolution of disease. However, uncommon cases may escape detection and the severity of the process may also go unrecognized without a careful assessment of clues available through physical examination and laboratory testing. In some cases a particularly virulent pathogen can lead to severe infection, septic shock and its consequences, even death, despite clinicians acting appropriately.
ERIC Educational Resources Information Center
Twissell, Adrian
2018-01-01
Abstract electronics concepts are difficult to develop because the phenomena of interest cannot be readily observed. Visualisation skills support learning about electronics and can be applied at different levels of representation and understanding (observable, symbolic and abstract). Providing learners with opportunities to make transitions…
Teaching the 'A' Level Text: Emma.
ERIC Educational Resources Information Center
Huband, David
1987-01-01
Notes how important it is that any critical writing assignments should take into account the individual reading, and that the teacher's role is to steer discussion that stems from a class of individual readings. Explores some of the aspects of Jane Austen's novel "Emma" to which students readily respond. (HTH)
ERIC Educational Resources Information Center
Buttimer, Annette
This resource paper on values in geography is one of several developed by the Commission on College Geography as expository documents for the use of both the student and instructor at the college level. They are designed to supplement existing texts and to fill a gap between significant research in geography and readily accessible materials. The…
Making a Microscope with Readily Available Materials
ERIC Educational Resources Information Center
Vannoni, Maurizio; Buah-Bassuah, Paul K.; Molesini, Giuseppe
2007-01-01
The making of microscope devices using inexpensive or recovered materials is demonstrated. Examples of images illustrating the performance of such devices are presented. As a project at the undergraduate level, the task is effective in acquiring familiarity with optical imaging concepts and their practical implementation in the laboratory.…
How New Zealand Consumers Respond to Plain English.
ERIC Educational Resources Information Center
Campbell, Nittaya
1999-01-01
Considers how New Zealand has seen a need for providing readily understandable business and government documents. Reports a psycholinguistic study testing the level of consumer comprehension of bank contracts, and the effect of using plain English to rewrite them. Finds that the most effective means of enhancing comprehension was that which…
46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...
46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...
46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...
46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...
46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... outlet connection or the quick-closing valve, even in the event of abnormal displacement of the piping.... Tables shall be readily available for direct determination of volume of liquid in the tanks, with necessary corrections for trim, temperature, and density. (2) An independent high level alarm shall be...
Effects of low levels of herbicides on potatoes, soybeans and peas grown in a greenhouse and outside
While laboratory toxicology tests are generally easy to perform, cost effective and readily interpreted, they have been questioned for their environmental relevance. In contrast, field tests are considered realistic while producing results that are difficult to interpret and exp...
A Controlled Environment System For Measuring Plant-Atmosphere Gas Exchange
James M. Brown
1975-01-01
Describes an inexpensive, efficient system for measuring plant-atmosphere gas exchange. Designed to measure transpiration from potted tree seedlings, it is readily adaptable for measuring other gas exchanges or gas exchange by plant parts. Light level, air and root temperature can be precisely controlled at minimum cost.
Integrating Science and Language Arts through Technology-based Macrocontexts.
ERIC Educational Resources Information Center
Kumar, David; Bristor, Valerie J.
1999-01-01
Videos, virtual reality, and the World Wide Web create effective macrocontexts for integrating science and language arts. Contexts must be readily available, appropriate for the level, and interesting to students. Teachers should be able to identify scientific concepts and language skills embedded in them. Alternative assessment methods are more…
USDA-ARS?s Scientific Manuscript database
Enzymatic bio-processing of cotton generates significantly less hazardous wastewater effluents, which are readily biodegradable, but it also has several critical shortcomings that impede its acceptance by industries: expensive processing costs and slow reaction rates. Our research has found that th...
USDA-ARS?s Scientific Manuscript database
Enzymatic bio-processing of cotton generates significantly less hazardous wastewater effluents, which are readily biodegradable, but it also has several critical shortcomings that impede its acceptance by industries: expensive processing costs and slow reaction rates. Our research has found that th...
Air Pollution. Resource Paper No. 2.
ERIC Educational Resources Information Center
Bryson, Reid A.; Kutzbach, John E.
These Resource Papers have been developed as expository documents for the use of both the student and the instructor in undergraduate college geography courses at the introductory and advanced level. They are designed to supplement existing texts and to fill a gap between significant research in American geography and readily accessible materials.…
Airborne emissions in the harbour and port of Cork.
Sodeau, John R; Hellebust, Stig; Allanic, Arnaud; O'Connor, Ian; Healy, David A; Healy, Robert; Wenger, John
2009-07-01
It is now accepted that the transport sector is responsible for a large and growing share of global emissions affecting both health and climate. The quantification of these effects requires, as an essential first step, a comprehensive analysis and characterization of the contributing subsectors, i.e. road transport, shipping, aviation and rail. The shipping contribution in dock/harbour areas is of particular interest because many vessels use old engines powered with old technology giving rise to high levels of particulate emissions mainly because the fuel employed contains high levels of sulphur, up to 4.5%. Large amounts of polyaromatic hydrocarbons and varying contents of transition metals are also detected. Few studies on the physicochemical composition of direct emissions from ship fuels have been performed; none have been compared to actual contents in local harbour or port atmospheres. The transformation of these ship-related materials to toxicologically active species may be much more efficient than corresponding road emission or domestic sources because of the expected highly acidic nature of the particulates. Surface, toxic material may therefore become readily bioavailable under such conditions but such studies have not been performed hitherto. This mini-review outlines in detail the issues raised above in the context of measurements made in Cork, Ireland.
Fondevila, Sabela; Martín-Loeches, Manuel; Jiménez-Ortega, Laura; Casado, Pilar; Sel, Alejandra; Fernández-Hernández, Anabel; Sommer, Werner
2012-01-01
Religious beliefs are both catchy and durable: they exhibit a high degree of adherence to our cognitive system, given their success of transmission and spreading throughout history. A prominent explanation for religion's cultural success comes from the "MCI hypothesis," according to which religious beliefs are both easy to recall and desirable to transmit because they are minimally counterintuitive (MCI). This hypothesis has been empirically tested at concept and narrative levels by recall measures. However, the neural correlates of MCI concepts remain poorly understood. We used the N400 component of the event-related brain potential as a measure of counterintuitiveness of violations comparing religious and non-religious sentences, both counterintuitive, when presented in isolation. Around 80% in either condition were core-knowledge violations. We found smaller N400 amplitudes for religious as compared to non-religious counterintuitive ideas, suggesting that religious ideas are less semantically anomalous. Moreover, behavioral measures revealed that religious ideas are not readily detected as unacceptable. Finally, systematic analyses of our materials, according to conceptual features proposed in cognitive models of religion, did not reveal any outstanding variable significantly contributing to these differences. Refinements of cognitive models of religion should elucidate which combination of factors renders an anomaly less counterintuitive and thus more suitable for recall and transmission.
Regulation of body temperature and brown adipose tissue thermogenesis by bombesin receptor subtype-3
Lateef, Dalya M.; Abreu-Vieira, Gustavo; Xiao, Cuiying
2014-01-01
Bombesin receptor subtype-3 (BRS-3) regulates energy homeostasis, with Brs3 knockout (Brs3−/y) mice being hypometabolic, hypothermic, and hyperphagic and developing obesity. We now report that the reduced body temperature is more readily detected if body temperature is analyzed as a function of physical activity level and light/dark phase. Physical activity level correlated best with body temperature 4 min later. The Brs3−/y metabolic phenotype is not due to intrinsically impaired brown adipose tissue function or in the communication of sympathetic signals from the brain to brown adipose tissue, since Brs3−/y mice have intact thermogenic responses to stress, acute cold exposure, and β3-adrenergic activation, and Brs3−/y mice prefer a cooler environment. Treatment with the BRS-3 agonist MK-5046 increased brown adipose tissue temperature and body temperature in wild-type but not Brs3−/y mice. Intrahypothalamic infusion of MK-5046 increased body temperature. These data indicate that the BRS-3 regulation of body temperature is via a central mechanism, upstream of sympathetic efferents. The reduced body temperature in Brs3−/y mice is due to altered regulation of energy homeostasis affecting higher center regulation of body temperature, rather than an intrinsic defect in brown adipose tissue. PMID:24452453
NASA Astrophysics Data System (ADS)
Wada, Hiroshi; Ando, Masayoshi; Takeuchi, Masataka; Sugawara, Hironori; Koike, Takuji; Kobayashi, Toshimitsu; Hozawa, Koji; Gemma, Takashi; Nara, Makoto
2002-05-01
``Time-averaged holography'' and ``holographic interferometry'' enable recording of the complete vibration pattern of a surface within several seconds. The results appear in the form of fringes. Vibration amplitudes smaller than 100 nm are not readily measurable by these techniques, because such small amplitudes produce variations in gray level, but not fringes. In practice, to obtain clear fringes in these measurements, stimulus sound pressures higher than 100 dB SPL must be used. The phase of motion is also not obtainable from such fringe techniques. In this study, a sinusoidal phase modulation technique is described, which allows detection of both small amplitudes of motion and their phase from time-averaged speckle pattern interferometry. In this technique, the laser injection current is modulated and digital image processing is used to analyze the measured patterns. When the sound-pressure level of stimuli is between 70 and 85 dB SPL, this system is applied to measure the vibratory response of the tympanic membrane (TM) of guinea pig temporal bones at frequencies up to 4 kHz where complicated vibration modes are observed. The effect of the bulla on TM displacements is also quantified. Results indicate that this system is capable of measuring the nanometer displacements of the TM, produced by stimuli of 70 dB SPL.
Organochlorine residues in females and nursing young of the big brown bat (Eptesicus fuscus)
Clark, D.R.; Lamont, T.G.
1976-01-01
Carcasses and brains of 18 big brown bats from Gaithersburg, Maryland, were analyzed for residues of organochlorine insecticides and PCB's. Eleven bats were adult females, and six of these had seven nursing young associated with them....Young bats resembled their parents in microgram amounts of PCB and DDE present in carcasses. However, concentrations of chemicals (expressed as ppm) were significantly higher in young. Brains of three young contained detectable residues of PCB and DDE....Younger adult females contained higher levels of PCB and DDE than did older ones. However, among the oldest females, amounts appeared to begin rising again. This pattern resembles that in free-tailed bats from Bracken Cave, Texas, but differs from the continuous linear decline seen in a Laurel, Maryland population of big brown bats, in which initial levels among younger females were higher than those in the Gaithersburg population....DDE was transferred from female to young more readily than was PCB by nursing. Five of 51 neonate big brown bats from the Laurel population were thought to have been born dead because of residues of PCB that were transferred across the placenta. Present data show that even greater amounts of PCB may be transferred to young by lactation and nursing.