Sample records for reagent kit abbott

  1. Standardization and optimization of fluorescence in situ hybridization (FISH) for HER-2 assessment in breast cancer: A single center experience.

    PubMed

    Bogdanovska-Todorovska, Magdalena; Petrushevska, Gordana; Janevska, Vesna; Spasevska, Liljana; Kostadinova-Kunovska, Slavica

    2018-05-20

    Accurate assessment of human epidermal growth factor receptor 2 (HER-2) is crucial in selecting patients for targeted therapy. Commonly used methods for HER-2 testing are immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). Here we presented the implementation, optimization and standardization of two FISH protocols using breast cancer samples and assessed the impact of pre-analytical and analytical factors on HER-2 testing. Formalin fixed paraffin embedded (FFPE) tissue samples from 70 breast cancer patients were tested for HER-2 using PathVysion™ HER-2 DNA Probe Kit and two different paraffin pretreatment kits, Vysis/Abbott Paraffin Pretreatment Reagent Kit (40 samples) and DAKO Histology FISH Accessory Kit (30 samples). The concordance between FISH and IHC results was determined. Pre-analytical and analytical factors (i.e., fixation, baking, digestion, and post-hybridization washing) affected the efficiency and quality of hybridization. The overall hybridization success in our study was 98.6% (69/70); the failure rate was 1.4%. The DAKO pretreatment kit was more time-efficient and resulted in more uniform signals that were easier to interpret, compared to the Vysis/Abbott kit. The overall concordance between IHC and FISH was 84.06%, kappa coefficient 0.5976 (p < 0.0001). The greatest discordance (82%) between IHC and FISH was observed in IHC 2+ group. A standardized FISH protocol for HER-2 assessment, with high hybridization efficiency, is necessary due to variability in tissue processing and individual tissue characteristics. Differences in the pre-analytical and analytical steps can affect the hybridization quality and efficiency. The use of DAKO pretreatment kit is time-saving and cost-effective.

  2. Evaluation of the Efficiency of the Sample Inactivation Reagent in the Abbott RealTime MTB Assay for Inactivation of Mycobacterium tuberculosis

    PubMed Central

    Wallis, Carole; Pahalawatta, Vihanga; Frank, Andrea; Ramdin, Neeshan; Viana, Raquel; Abravaya, Klara; Leckie, Gregor; Tang, Ning

    2015-01-01

    The Abbott RealTime MTB assay is a nucleic acid amplification test (NAAT) for the detection of Mycobacterium tuberculosis complex DNA. The sample inactivation procedure used in the assay, consisting of one part sample treated with 3 parts inactivation reagent for 60 min, effectively reduced viscosity and inactivated M. tuberculosis in clinical specimens. PMID:26085611

  3. Evaluation of the Efficiency of the Sample Inactivation Reagent in the Abbott RealTime MTB Assay for Inactivation of Mycobacterium tuberculosis.

    PubMed

    Qi, Chao; Wallis, Carole; Pahalawatta, Vihanga; Frank, Andrea; Ramdin, Neeshan; Viana, Raquel; Abravaya, Klara; Leckie, Gregor; Tang, Ning

    2015-09-01

    The Abbott RealTime MTB assay is a nucleic acid amplification test (NAAT) for the detection of Mycobacterium tuberculosis complex DNA. The sample inactivation procedure used in the assay, consisting of one part sample treated with 3 parts inactivation reagent for 60 min, effectively reduced viscosity and inactivated M. tuberculosis in clinical specimens. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  4. [Performance evaluation of Abbott RealTime HBV Quantification Kit for HBV viral load by real-time PCR].

    PubMed

    Kim, Myeong Hee; Cha, Choong Hwan; An, Dongheui; Choi, Sung Eun; Oh, Heung Bum

    2008-04-01

    Hepatitis B virus (HBV) DNA quantification is necessary for starting and monitoring of antiviral therapy in patients with chronic hepatitis B. This study was intended to assess the clinical performance of Abbott RealTime HBV Quantification kit (Abbott Laboratories, USA). The performance was evaluated in terms of precision, linearity, detection sensitivity, cross-reactivity, and carry-over. A correlation with the Real-Q HBV Quantification kit (BioSewoom Inc., Korea) was also examined using serum samples from 64 patients diagnosed with chronic hepatitis B and underwent lamivudine therapy in Asan Medical Center. We verified the trueness of the system by comparing the outputs with the assigned values of the BBI panel (BBI Diagnostics, USA). Within-run and between-run coefficients of variation (CV) were 3.56-4.71% and 3.03-4.98%, respectively. Linearity was manifested ranging from 53 to 10(9)copies/mL and the detection sensitivity was verified to be 51 copies/mL. None of hepatitis C virus showed cross-reactivity. No cross-contamination occurred when negative and positive samples were alternatively placed in a row. It showed a good correlation with the Real-Q HBV (r(2)=0.9609) and the test results for the BBI panel were also well agreed to the assigned values (r(2)=0.9933). The performance of Abbott RealTime HBV Quantification kit was excellent; thus, it should be widely used in starting and monitoring of antiviral therapy in Korean patients with chronic hepatitis B.

  5. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...

  6. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...

  7. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...

  8. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...

  9. Comparative evaluation of three automated systems for DNA extraction in conjunction with three commercially available real-time PCR assays for quantitation of plasma Cytomegalovirus DNAemia in allogeneic stem cell transplant recipients.

    PubMed

    Bravo, Dayana; Clari, María Ángeles; Costa, Elisa; Muñoz-Cobo, Beatriz; Solano, Carlos; José Remigia, María; Navarro, David

    2011-08-01

    Limited data are available on the performance of different automated extraction platforms and commercially available quantitative real-time PCR (QRT-PCR) methods for the quantitation of cytomegalovirus (CMV) DNA in plasma. We compared the performance characteristics of the Abbott mSample preparation system DNA kit on the m24 SP instrument (Abbott), the High Pure viral nucleic acid kit on the COBAS AmpliPrep system (Roche), and the EZ1 Virus 2.0 kit on the BioRobot EZ1 extraction platform (Qiagen) coupled with the Abbott CMV PCR kit, the LightCycler CMV Quant kit (Roche), and the Q-CMV complete kit (Nanogen), for both plasma specimens from allogeneic stem cell transplant (Allo-SCT) recipients (n = 42) and the OptiQuant CMV DNA panel (AcroMetrix). The EZ1 system displayed the highest extraction efficiency over a wide range of CMV plasma DNA loads, followed by the m24 and the AmpliPrep methods. The Nanogen PCR assay yielded higher mean CMV plasma DNA values than the Abbott and the Roche PCR assays, regardless of the platform used for DNA extraction. Overall, the effects of the extraction method and the QRT-PCR used on CMV plasma DNA load measurements were less pronounced for specimens with high CMV DNA content (>10,000 copies/ml). The performance characteristics of the extraction methods and QRT-PCR assays evaluated herein for clinical samples were extensible at cell-based standards from AcroMetrix. In conclusion, different automated systems are not equally efficient for CMV DNA extraction from plasma specimens, and the plasma CMV DNA loads measured by commercially available QRT-PCRs can differ significantly. The above findings should be taken into consideration for the establishment of cutoff values for the initiation or cessation of preemptive antiviral therapies and for the interpretation of data from clinical studies in the Allo-SCT setting.

  10. Performance evaluation of the QIAGEN EZ1 DSP Virus Kit with Abbott RealTime HIV-1, HBV and HCV assays.

    PubMed

    Schneider, George J; Kuper, Kevin G; Abravaya, Klara; Mullen, Carolyn R; Schmidt, Marion; Bunse-Grassmann, Astrid; Sprenger-Haussels, Markus

    2009-04-01

    Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.

  11. Verification of Abbott 25-OH-vitamin D assay on the architect system.

    PubMed

    Hutchinson, Katrina; Healy, Martin; Crowley, Vivion; Louw, Michael; Rochev, Yury

    2017-04-01

    Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD) assays, and an examination of reference Intervals. Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaSorin Liaison and AB SCIEX API 4000 (LC-MS/MS). Establishment of uncertainty of measurement for 25OHD Architect methods using old and new generations of the reagents, and estimation of reference interval in healthy Irish population. For between-run precision the manufacturer claims 2.8% coefficients of variation (CVs) of 2.8% and 4.6% for their high and low controls, respectively. Our instrument showed CVs between 4% and 6.2% for all levels of the controls on both generations of the Abbott reagents. The between-run uncertainties were 0.28 and 0.36, with expanded uncertainties 0.87 and 0.98 for the old and the new generations of reagent, respectively. The difference between all methods used for patients' samples was within total allowable error, and the instruments produced clinically equivalent results. The results covered the medical decision points of 30, 40, 50 and 125 nmol/L. The reference interval for total 25OHD in our healthy Irish subjects was lower than recommended levels (24-111 nmol/L). In a clinical laboratory Abbott 25OHD immunoassays are a useful, rapid and accurate method for measuring total 25OHD. The new generation of the assay was confirmed to be reliable, accurate, and a good indicator for 25OHD measurement. More study is needed to establish reference intervals that correctly represent the healthy population in Ireland.

  12. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  13. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  14. Cross-reactions of reagents from streptococcal grouping kits with Streptococcus porcinus.

    PubMed Central

    Thompson, T; Facklam, R

    1997-01-01

    Streptococcus porcinus is usually associated with swine. Because we have received several isolates from human sources that had cross-reacted with commercial group B streptococcal reagents, we examined several commercial kits to determine the extent of this cross-reaction. Fifteen reference and 15 clinical strains of S. porcinus were tested for cross-reactions with group B streptococcal reagents from 12 different commercial kits. Cross-reactions were detected with all group B reagents, but the number of cross-reactions varied with each kit. We recommend that manufacturers of reagents designed to identify group B streptococci by serologic methods test their reagents for cross-reactions with selected S. porcinus cultures or antigens. PMID:9196216

  15. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for blood banking reagents... SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a...

  16. Performance Characteristics and Comparison of Abbott and artus Real-Time Systems for Hepatitis B Virus DNA Quantification ▿

    PubMed Central

    Ismail, Ashrafali M.; Sivakumar, Jayashree; Anantharam, Raghavendran; Dayalan, Sujitha; Samuel, Prasanna; Fletcher, Gnanadurai J.; Gnanamony, Manu; Abraham, Priya

    2011-01-01

    Virological monitoring of hepatitis B virus (HBV) DNA is critical to the management of HBV infection. With several HBV DNA quantification assays available, it is important to use the most efficient testing system for virological monitoring. In this study, we evaluated the performance characteristics and comparability of three HBV DNA quantification systems: Abbott HBV real-time PCR (Abbott PCR), artus HBV real-time PCR with QIAamp DNA blood kit purification (artus-DB), and artus HBV real-time PCR with the QIAamp DSP virus kit purification (artus-DSP). The lower limits of detection of these systems were established against the WHO international standards for HBV DNA and were found to be 1.43, 82, and 9 IU/ml, respectively. The intra-assay and interassay coefficients of variation of plasma samples (1 to 6 log10 IU/ml) ranged between 0.05 to 8.34% and 0.16 to 3.48% for the Abbott PCR, 1.53 to 26.85% and 0.50 to 12.89% for artus-DB, and 0.29 to 7.42% and 0.94 to 3.01% for artus-DSP, respectively. Ninety HBV clinical samples were used for comparison of assays, and paired quantitative results showed strong correlation by linear regression analysis (artus-DB with Abbott PCR, r = 0.95; Abbott PCR with artus-DSP, r = 0.97; and artus-DSP with artus-DB, r = 0.94). Bland-Altman analysis showed a good level of agreement for Abbott PCR and artus-DSP, with a mean difference of 0.10 log10 IU/ml and limits of agreement of −0.91 to 1.11 log10 IU/ml. No genotype-specific bias was seen in all three systems for HBV genotypes A, C, and D, which are predominant in this region. This finding illustrates that the Abbott real-time HBV and artus-DSP systems show more comparable performance than the artus-DB system, meeting the current guidelines for assays to be used in the management of hepatitis B. PMID:21795507

  17. Performance characteristics and comparison of Abbott and artus real-time systems for hepatitis B virus DNA quantification.

    PubMed

    Ismail, Ashrafali M; Sivakumar, Jayashree; Anantharam, Raghavendran; Dayalan, Sujitha; Samuel, Prasanna; Fletcher, Gnanadurai J; Gnanamony, Manu; Abraham, Priya

    2011-09-01

    Virological monitoring of hepatitis B virus (HBV) DNA is critical to the management of HBV infection. With several HBV DNA quantification assays available, it is important to use the most efficient testing system for virological monitoring. In this study, we evaluated the performance characteristics and comparability of three HBV DNA quantification systems: Abbott HBV real-time PCR (Abbott PCR), artus HBV real-time PCR with QIAamp DNA blood kit purification (artus-DB), and artus HBV real-time PCR with the QIAamp DSP virus kit purification (artus-DSP). The lower limits of detection of these systems were established against the WHO international standards for HBV DNA and were found to be 1.43, 82, and 9 IU/ml, respectively. The intra-assay and interassay coefficients of variation of plasma samples (1 to 6 log(10) IU/ml) ranged between 0.05 to 8.34% and 0.16 to 3.48% for the Abbott PCR, 1.53 to 26.85% and 0.50 to 12.89% for artus-DB, and 0.29 to 7.42% and 0.94 to 3.01% for artus-DSP, respectively. Ninety HBV clinical samples were used for comparison of assays, and paired quantitative results showed strong correlation by linear regression analysis (artus-DB with Abbott PCR, r = 0.95; Abbott PCR with artus-DSP, r = 0.97; and artus-DSP with artus-DB, r = 0.94). Bland-Altman analysis showed a good level of agreement for Abbott PCR and artus-DSP, with a mean difference of 0.10 log(10) IU/ml and limits of agreement of -0.91 to 1.11 log(10) IU/ml. No genotype-specific bias was seen in all three systems for HBV genotypes A, C, and D, which are predominant in this region. This finding illustrates that the Abbott real-time HBV and artus-DSP systems show more comparable performance than the artus-DB system, meeting the current guidelines for assays to be used in the management of hepatitis B.

  18. Automated quantification of Epstein-Barr Virus in whole blood of hematopoietic stem cell transplant patients using the Abbott m2000 system.

    PubMed

    Salmona, Maud; Fourati, Slim; Feghoul, Linda; Scieux, Catherine; Thiriez, Aline; Simon, François; Resche-Rigon, Matthieu; LeGoff, Jérôme

    2016-08-01

    Accurate quantification of Epstein-Barr virus (EBV) load in blood is essential for the management of post-transplant lymphoproliferative disorders. The automation of DNA extraction and amplification may improve accuracy and reproducibility. We evaluated the EBV PCR Kit V1 with fully automated DNA extraction and amplification on the m2000 system (Abbott assay). Conversion factor between copies and international units (IU), lower limit of quantification, imprecision and linearity were determined in a whole blood (WB) matrix. Results from 339 clinical WB specimens were compared with a home-brew real-time PCR assay used in our laboratory (in-house assay). The conversion factor between copies and IU was 3.22 copies/IU. The lower limit of quantification (LLQ) was 1000 copies/mL. Intra- and inter-assay coefficients of variation were 3.1% and 7.9% respectively for samples with EBV load higher than the LLQ. The comparison between Abbott assay and in-house assay showed a good concordance (kappa = 0.77). Loads were higher with the Abbott assay (mean difference = 0.62 log10 copies/mL). The EBV PCR Kit V1 assay on the m2000 system provides a reliable and easy-to-use method for quantification of EBV DNA in WB. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Occurrence of nonspecific reactions among stool specimens tested by the Abbott TestPack rotavirus enzyme immunoassay.

    PubMed Central

    Lipson, S M; Leonardi, G P; Salo, R J; Schutzbank, T E; Kaplan, M H

    1990-01-01

    Sixty-five stool specimens obtained from children suffering from gastroenteritis were tested for the presence of antigen to rotavirus by the Abbott TestPack Rotavirus (TestPack) enzyme immunoassay kit. The Kallestad Pathfinder enzyme immunoassay, polyacrylamide gel electrophoresis, immune electron microscopy, and virus isolation were utilized as reference assays. Fifty-four specimens were in accord by TestPack and Kallestad Pathfinder. Among 11 discordant specimens positive with TestPack but negative by Kallestad Pathfinder, rotavirus was not identified by polyacrylamide gel electrophoresis, immune electron microscopy, or isolation in primary African green monkey kidney cell cultures. TestPack displayed a performance specificity of 83%. The inordinately high number of stool specimens reported as false-positive by TestPack precludes the incorporation of this antigen detection kit into our routine regimen of diagnostic virologic testing. Images PMID:2166074

  20. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Immunohistochemistry reagents and kits. 864.1860 Section 864.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1860...

  1. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Immunohistochemistry reagents and kits. 864.1860 Section 864.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1860...

  2. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Immunohistochemistry reagents and kits. 864.1860 Section 864.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1860...

  3. Impact of the New Abbott mPLUS Feature on Clinical Laboratory Efficiencies of Abbott RealTime Assays for Detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae

    PubMed Central

    Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-01-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflows based on sample arrival patterns. The flexibility in sample batch size offered by mPLUS enables significant reductions in processing times. For hepatitis B virus tests, a reduction in sample turnaround times of up to 30% (105 min) was observed for batches of 12 samples compared with those for batches of 24 samples; for Chlamydia trachomatis/Neisseria gonorrhoeae tests, the ability to run batches of 24 samples reduced the turnaround time by 83% (54 min) compared with that for batches of 48 samples. Excellent correlations between mPLUS and m2000 standard condition results were observed for all RealTime viral load assays evaluated in this study, with correlation r values of 0.998 for all assays tested. For the qualitative RealTime C. trachomatis/N. gonorrhoeae assay, the overall agreements between the two conditions tested were >98% for C. trachomatis and 100% for N. gonorrhoeae. Comparable precision results were observed for the two conditions tested for all RealTime assays. The enhanced mPLUS capability provides clinical laboratories with increased efficiencies to meet increasingly stringent turnaround time requirements without increased costs associated with discarding partially used amplification reagents. PMID:24088850

  4. Impact of the New Abbott mPLUS feature on clinical laboratory efficiencies of abbott RealTime assays for detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae.

    PubMed

    Lucic, Danijela; Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-12-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflows based on sample arrival patterns. The flexibility in sample batch size offered by mPLUS enables significant reductions in processing times. For hepatitis B virus tests, a reduction in sample turnaround times of up to 30% (105 min) was observed for batches of 12 samples compared with those for batches of 24 samples; for Chlamydia trachomatis/Neisseria gonorrhoeae tests, the ability to run batches of 24 samples reduced the turnaround time by 83% (54 min) compared with that for batches of 48 samples. Excellent correlations between mPLUS and m2000 standard condition results were observed for all RealTime viral load assays evaluated in this study, with correlation r values of 0.998 for all assays tested. For the qualitative RealTime C. trachomatis/N. gonorrhoeae assay, the overall agreements between the two conditions tested were >98% for C. trachomatis and 100% for N. gonorrhoeae. Comparable precision results were observed for the two conditions tested for all RealTime assays. The enhanced mPLUS capability provides clinical laboratories with increased efficiencies to meet increasingly stringent turnaround time requirements without increased costs associated with discarding partially used amplification reagents.

  5. Performance evaluation of four dominant anti-hepatitis B core antigen (HBcAb) kits in Japan for preventing de novo hepatitis B virus (HBV) infection.

    PubMed

    Kobayashi, Eiji; Deguchi, Matsuo; Kagita, Masanori; Yoshioka, Nori; Kita, Mifumi; Asari, Seishi; Suehisa, Etsuji; Hidaka, Yoh; Iwatani, Yoshinori

    2015-01-01

    The determination of antibody to hepatitis B core antigen (HBcAb) has become an important means of evaluating the risk factors of de novo hepatitis B virus (HBV) infection before starting intensive immunosuppressive drug therapies. Four dominant HBcAb determination reagents used in Japan were evaluated with HBcIgM, HBsAg, HBsAb, HBeAb, and HBV DNA reagents in order to study their clinical utility. Four kinds of HBcAb reagent kits (HBcAb Total and HBcAb-IgG reagent) were evaluated with 526 clinical specimens, including 344 negative specimens, at Osaka University Hospital. The dynamic range of each kit was evaluated by testing serially diluted serum from pooled sera with high HBcAb concentration. The reagent that showed the largest dynamic range was the Lumipulse HBcAb-N (HBcAb-IgG reagent). Regarding clinical sensitivity and specificity, Centaur HBcAb (HBcAb Total reagent) gave several "doubtful negative" results and ARCHITECT HBcII (HBcAb Total reagent) had the most discrepant positive results. By comparing the cut-off-index distribution of negative specimens using a parameter of "distance from the mean to the cut-off divided by the SD", Centaur was determined to be the best (distance/SD = 12.65), with Lumipulse and Elecsys Anti-HBc (HBcAb Total reagent) in the second group (8.13 and 7.00, respectively), and ARCHITECT rated as the worst (3.25). In this evaluation, Elecsys and Lumipulse HBcAb kits showed good clinical sensitivity and specificity and were considered to be suitable for evaluating the risk factors of de novo HBV infection.

  6. Evaluation of a new automated Abbott RealTime MTB RIF/INH assay for qualitative detection of rifampicin/isoniazid resistance in pulmonary and extra-pulmonary clinical samples of Mycobacterium tuberculosis.

    PubMed

    Ruiz, Pilar; Causse, Manuel; Vaquero, Manuel; Gutierrez, Juan Bautista; Casal, Manuel

    2017-01-01

    A new automated real-time PCR assay for the detection of rifampicin (RIF) and isoniazid (INH) resistance in Mycobacterium tuberculosis (MTB) was evaluated. A total of 163 clinical samples (128 pulmonary and 35 extra-pulmonary) were processed using four PCR assay kits: Abbott RealTime MTB RIF/INH, Genotype MTBDRplus, Xpert/MTB RIF, and Anyplex MTB/MDR. The results of phenotypic drug-susceptibility testing using BACTECMGIT 960 were used as reference. The sensitivity and specificity of the new Abbott RealTime MTB RIF/INH assay in comparison with phenotypic testing was 96.3% (95%CI 87.32%-100%) for RIF and 100% (95%CI 99.3%-100%) for INH; the sensitivity was 78.8% (95%CI 66.8%-90.9%) and the specificity was 100% (95%CI 98.9%-100%). The Abbott RealTime MTB RIF/INH test could be a valid method for detecting the most common mutations in strains resistant to RIF and INH.

  7. Evaluation of four commercial biuret reagent kits of serum total protein by the American Association for Clinical Chemistry reference measurement procedure.

    PubMed

    He, Meilin; Zhang, Jie

    2011-06-01

    In China, the traceability of clinical chemistry methods is still immature. Therefore, it is necessary to establish a reference measurement procedure and evaluate commercial reagent kits using such established procedures. We reproduced the reference measurement procedure for serum total protein, as recommended by the American Association for Clinical Chemistry (AACC). We evaluated the performance by Clinical Laboratory Standard Institute (CLSI) guidelines EP15-A and EP6-A. Subsequently, four commercial reagent kits were evaluated by the reproduced reference procedure following CLSI guideline EP9-A2. The performance of the reproduced reference procedure was as follows: CVs ranged from 0.47% to 0.85% at medical decision levels (X(c)) of 45 g/L, 60 g/L and 80 g/L. Linearity was Y=1.0022X-0.2121 (r=0.9999), and recovery ranged from 100.2% to 102.4%. The External Quality Assessment Scheme for Reference Laboratories in Laboratory Medicine (RELA) was applied, and the result was within the limit of equivalence. The linear relationships of four commercial reagent kits, Merit Choice, KHB, Leadman, and Olympus, were, respectively: Y=0.9922X+0.5776 (r=0.9961); Y=0.9936X+0.4316 (r=0.9992); Y=0.9949X+0.9129 (r=0.9987) and Y=0.9923X+0.8876 (r=0.9989). KHB showed slight negative bias, and the mean±SD was -0.03±0.60 g/L. Merit Choice, Leadman, and Olympus all showed positive bias, and the mean±SDs were 0.02±0.63 g/L, 0.55±0.77 g/L and 0.34±0.71 g/L, respectively. The correlation and bias of four commercial reagent kits for serum total protein were found to be acceptable. Thus, these reagent kits can be used reliably in China.

  8. [The validation of kit of reagents for quantitative detection of DNA of human cytomegalovirus in biological material using polymerase chain reaction technique in real time operation mode].

    PubMed

    Sil'veĭstrova, O Iu; Domonova, É A; Shipulina, O Iu

    2014-04-01

    The validation of kit of reagents destined to detection and quantitative evaluation of DNA of human cytomegalovirus in biological material using polymerase chain reaction technique in real time operation mode was implemented. The comparison was made against international WHO standard--The first WHO international standard for human cytomegalovirus to implement measures the kit of reagents "AmpliSens CMV-screen/monitor-FL" and standard sample of enterprise DNA HCMV (The central research institute of epidemiology of Rospotrebnadzor) was applied. The fivefold dilution of international WHO standard and standard sample of enterprise were carried out in concentrations of DNA HCMV from 106 to 102. The arrangement of polymerase chain reaction and analysis of results were implemented using programed amplifier with system of detection of fluorescent signal in real-time mode "Rotor-Gene Q" ("Qiagen", Germany). In the total of three series of experiments, all stages of polymerase chain reaction study included, the coefficient of translation of quantitative evaluation of DNA HCMV from copy/ml to ME/ml equal to 0.6 was introduced for this kit of reagents.

  9. Protein crystallography prescreen kit

    DOEpatents

    Segelke, Brent W.; Krupka, Heike I.; Rupp, Bernhard

    2007-10-02

    A kit for prescreening protein concentration for crystallization includes a multiplicity of vials, a multiplicity of pre-selected reagents, and a multiplicity of sample plates. The reagents and a corresponding multiplicity of samples of the protein in solutions of varying concentrations are placed on sample plates. The sample plates containing the reagents and samples are incubated. After incubation the sample plates are examined to determine which of the sample concentrations are too low and which the sample concentrations are too high. The sample concentrations that are optimal for protein crystallization are selected and used.

  10. Protein crystallography prescreen kit

    DOEpatents

    Segelke, Brent W.; Krupka, Heike I.; Rupp, Bernhard

    2005-07-12

    A kit for prescreening protein concentration for crystallization includes a multiplicity of vials, a multiplicity of pre-selected reagents, and a multiplicity of sample plates. The reagents and a corresponding multiplicity of samples of the protein in solutions of varying concentrations are placed on sample plates. The sample plates containing the reagents and samples are incubated. After incubation the sample plates are examined to determine which of the sample concentrations are too low and which the sample concentrations are too high. The sample concentrations that are optimal for protein crystallization are selected and used.

  11. Development and validation of an ELISA kit (YF MAC-HD) to detect IgM to yellow fever virus.

    PubMed

    Basile, Alison Jane; Goodman, Christin; Horiuchi, Kalanthe; Laven, Janeen; Panella, Amanda J; Kosoy, Olga; Lanciotti, Robert S; Johnson, Barbara W

    2015-12-01

    Yellow fever virus (YFV) is endemic in tropical and sub-tropical regions of the world, with around 180,000 human infections a year occurring in Africa. Serologic testing is the chief laboratory diagnostic means of identifying an outbreak and to inform the decision to commence a vaccination campaign. The World Health Organization disseminates the reagents for YFV testing to African reference laboratories, and the US Centers for Disease Control and Prevention (CDC) is charged with producing and providing these reagents. The CDC M-antibody capture ELISA is a 2-day test, requiring titration of reagents when new lots are received, which leads to inconsistency in testing and wastage of material. Here we describe the development of a kit-based assay (YF MAC-HD) based upon the CDC method, that is completed in approximately 3.5h, with equivocal samples being reflexed to an overnight protocol. The kit exhibits >90% accuracy when compared to the 2-day test. The kits were designed for use with a minimum of equipment and are stored at 4°C, removing the need for freezing capacity. This kit is capable of tolerating temporary sub-optimal storage conditions which will ease shipping or power outage concerns, and a shelf life of >6 months was demonstrated with no deterioration in accuracy. All reagents necessary to run the YF MAC-HD are included in the kit and are single-use, with 8 or 24 sample options per kit. Field trials are envisioned for the near future, which will enable refinement of the method. The use of the YF MAC-HD is anticipated to reduce materials wastage, and improve the quality and consistency of YFV serologic testing in endemic areas. Published by Elsevier B.V.

  12. [Comparison of commercial HIV-1 viral load tests by using proficiency test results in China, 2013- 2015].

    PubMed

    Zhang, L; Jin, C; Jiang, Z; Tang, T; Jiang, Y; Pan, P L

    2017-09-10

    Objective: To compare the bio-equivalence among commercial HIV-1 viral load tests, including EasyQ HIV-1 v2.0 (EasyQ) from bioMerieux NucliSens of France; VERSANT HIV-1 RNA 3.0 assay (bDNA) from Siemens Healthcare Diagnostics of USA; COBAS AmpliPrep/COBAS TaqMan HIV-1 test (Taqman) from Roche Molecular Diagnosis of USA; Abbott Real Time HIV-1 Kit (M2000) from Abbott Molecular of USA and two domestic HIV-1 viral load test kits (domestic kit) from DaAn Gene Company of Sun Yat-Sen University and Liaoning Bio-Pharmaceutical company of Northeast pharmaceutical group, by using proficiency test results in China from 2013 to 2015. Methods: A total of 2 954 proficiency test results, obtained from 22 positive samples of 6 proficiency tests in 155 laboratories conducted by China CDC were analyzed during 2013-2015. The results from each sample were first logarithmic transformed and then grouped according to the method used, the mean value of logarithmic results was calculated. Subsequently, 22 clusters of mean values were analyzed by Bland-Altman analysis for the consistency, and linear regression analysis for the interdependency. Results: The results indicated that, by taking Taqman as the reference, EasyQ, M2000, bDNA and domestic kit had good consistency (90 % -100 % ) and interdependency. Conclusion: All the viral load tests were bio-equivalent. Moreover, according to the conversion formula derived from domestic proficiency test results, all the viral load results could be converted, which is critical for epidemiological analysis.

  13. [The efficiency of the enzyme immunoassay test system opisthorchiasis-CIC-EIA-best to detect circulating immune complexes containing opisthorchis antigens in the serum of patients with opisthorchiasis].

    PubMed

    Starkova, T V; Poletaeva, O G; Kovrova, E A; Krasovskaia, N N; Tkachenko, T N; Masiago, A V; Ofitserov, V I; Tereshchenko, A Iu

    2011-01-01

    The efficacy of a kit of Opisthorchiasis-CIC-EIA-Best reagents was evaluated using 270 sera from patients in the study and control groups. The kit showed a sufficient sensitivity (not less than 87.2%) and a high specificity (not less than 97.9%). The use of the above kit of the reagents for enzyme immunoassay in practical healthcare enables one to increase detection rates among the infested subjects on comprehensive examination of those with suspected opisthorchiasis.

  14. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    PubMed

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  15. 21 CFR 866.4100 - Complement reagent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4100... a component part of serological test kits used in the diagnosis of disease. (b) Classification...

  16. Field kit and method for testing for the presence of gunshot residue

    DOEpatents

    Rodacy, Philip J.; Walker, Pamela K.

    2003-09-02

    A field test kit for gunshot residue comprises a container having at least compartments separated by a barrier. A surface is tested by wiping it with a swab and placing the swab in a first compartment. The barrier is then breached, permitting reagent in the second compartment to flow onto the swab. The first compartment is transparent, and a color change will be observed if the reagent reacts with gunshot residue.

  17. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    PubMed

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-07-01

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  18. Chemical analysis kit for the presence of explosives

    DOEpatents

    Eckels, Joel Del [Livermore, CA; Nunes,; Peter, J [Danville, CA; Alcaraz, Armando [Livermore, CA; Whipple, Richard E [Livermore, CA

    2011-05-10

    A tester for testing for explosives associated with a test location comprising a first explosives detecting reagent; a first reagent holder, the first reagent holder containing the first explosives detecting reagent; a second explosives detecting reagent; a second reagent holder, the second reagent holder containing the second explosives detecting reagent; a sample collection unit for exposure to the test location, exposure to the first explosives detecting reagent, and exposure to the second explosives detecting reagent; and a body unit containing a heater for heating the sample collection unit for testing the test location for the explosives.

  19. Effect of Carthamus tinctorius (Safflower) on fasting blood glucose and insulin levels in alloxan induced diabetic rabbits.

    PubMed

    Qazi, Nasreen; Khan, Rafeeq Alam; Rizwani, Ghazala H; Feroz, Zeeshan

    2014-03-01

    Diabetes mellitus is a major threat to present and future generations. The role of herbal medication has emerged as a safe alternative to currently available medication due to its decreased potential to produce side effects, hence effect of Carthamus tinctorius was observed on fasting blood glucose and insulin levels in alloxan induced diabetic rabbits. Thirty five healthy male rabbits were divided into 5 groups with 7 rabbits in each (Normal control, diabetic control, diabetic treated with glibenclamide, diabetic treated with Carthamus tinctorius extract at doses of 200 and 300mg/kg of body weight). Drug and extract were given orally for 30 days and the values for blood glucose levels were observed after 15(th) and 30(th) day of treatment by using standard reagent kits provided by Human Germany. While insulin levels were checked at the end of the study by using Architect i1000 by Abbott Diagnostics USA. Animals were also observed for any gross toxicity during the study. Results revealed that Carthamus tinctorius has significant hypoglycemic effect at 200mg/kg and 300mg/kg doses as compared to diabetic control group. Insulin levels were significantly increased in Glibenclamide treated as well as Carthamus tinctorius treated groups as compared to diabetic control.

  20. Developmental Validation of Short Tandem Repeat Reagent Kit for Forensic DNA Profiling of Canine Biological Materials

    PubMed Central

    Dayton, Melody; Koskinen, Mikko T; Tom, Bradley K; Mattila, Anna-Maria; Johnston, Eric; Halverson, Joy; Fantin, Dennis; DeNise, Sue; Budowle, Bruce; Smith, David Glenn; Kanthaswamy, Sree

    2009-01-01

    Aim To develop a reagent kit that enables multiplex polymerase chain reaction (PCR) amplification of 18 short tandem repeats (STR) and the canine sex-determining Zinc Finger marker. Methods Validation studies to determine the robustness and reliability in forensic DNA typing of this multiplex assay included sensitivity testing, reproducibility studies, intra- and inter-locus color balance studies, annealing temperature and cycle number studies, peak height ratio determination, characterization of artifacts such as stutter percentages and dye blobs, mixture analyses, species-specificity, case type samples analyses and population studies. Results The kit robustly amplified domesticated dog samples and consistently generated full 19-locus profiles from as little as 125 pg of dog DNA. In addition, wolf DNA samples could be analyzed with the kit. Conclusion The kit, which produces robust, reliable, and reproducible results, will be made available for the forensic research community after modifications based on this study’s evaluation to comply with the quality standards expected for forensic casework. PMID:19480022

  1. Comparison of clinical application of the Abbott HBV PCR kit and the VERSANT HBV DNA 3.0 test to measure serum hepatitis B virus DNA in Taiwanese patients.

    PubMed

    Yang, Jeng-Fu; Lin, Ya-Yun; Huang, Jee-Fu; Liu, Shu-Fen; Chu, Pei-Yu; Hsieh, Ming-Yen; Lin, Zu-Yau; Chen, Shinn-Cherng; Wang, Liang-Yen; Dai, Chia-Yen; Chuang, Wan-Long; Yu, Ming-Lung

    2009-08-01

    With an estimated 350-400 million people worldwide chronically infected with hepatitis B virus (HBV), and the subsequent serious complications caused by liver damage including cirrhosis, liver failure, and hepatocellular carcinoma, HBV infection remains a global health issue, particularly in Taiwan, an HBV-hyperendemic area. Sensitive and accurate quantification of HBV DNA is necessary to monitor patients with chronic hepatitis B who are receiving antiviral therapy to determine treatment response and adapt therapy. We evaluated and compared the clinical performance of two HBV DNA assays based on different technologies: the RealArt HBV PCR Kit (Abbott HBV DNA PCR kit, real-time polymerase chain reaction assay, detection limit: 27 IU/mL) and the VERSANT bDNA 3.0 assay (Bayer, branched DNA signal amplification assay, detection limit: 357 IU/mL). Serum levels of HBV DNA in 173 chronic HBV carriers were determined using both the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 test. Of the 173 samples analyzed for baseline viral load detection, HBV DNA was quantifiable in 147 patients (82.1%) by the RealArt HBV PCR Kit, which was significantly higher than the 92 (53.2%) samples quantified by the VERSANT bDNA 3.0 assay. A total of 86 (49.7%) samples were quantifiable by both assays, whereas 25 (14.5%) were below the detection limit of both assays. The HBV DNA quantification values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were positively correlated (Spearman's rank correlation coefficient r = 0.932, p < 0.001). On average, the results derived from the RealArt HBV PCR Kit were 0.67 log lower than those of the VERSANT bDNA 3.0 assay. HBV DNA concentrations were significantly higher in 63 HBV e antigen (HBeAg)-seropositive patients than in 110 HBeAg-seronegative patients (5.42 +/- 2.34 logs vs. 3.21 +/- 2.27 logs, p < 0.001). The RealArt HBV PCR Kit is more sensitive and has a wider dynamic range than the VERSANT bDNA 3.0 assay in the clinical setting of chronic hepatitis B patients. The sensitivity and wide dynamic range of the PCR assay allow optimal monitoring and timely adaptation of antiviral therapy. Nevertheless, the HBV DNA values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were significantly correlated.

  2. Evaluation of nine immunoassay kits (enzyme immunoassay and direct fluorescence) for detection of Giardia lamblia and Cryptosporidium parvum in human fecal specimens.

    PubMed Central

    Garcia, L S; Shimizu, R Y

    1997-01-01

    It is well known that Giardia lamblia and Cryptosporidium parvum can cause severe symptoms in humans, particularly those who are immunologically compromised. Immunoassay procedures offer both increased sensitivity and specificity compared to conventional staining methods. These reagents are also helpful when screening large numbers of patients, particularly in an outbreak situation or when screening patients with minimal symptoms. The data obtained by using 9 diagnostic kits were compared: direct fluorescent-antibody assay (DFA) kits (TechLab Giardia/Crypto IF kit, TechLab Crypto IF kit, and Meridian Merifluor Cryptosporidium/Giardia) and enzyme immunoassay (EIA) kits (Alexon ProSpecT Giardia EZ Microplate Assay, Alexon ProSpecT Cryptosporidium Microplate Assay, Cambridge Giardia lamblia Antigen Microwell ELISA, Meridian Premier Giardia lamblia, Meridian Premier Cryptosporidium, TechLab Giardia CELISA, Trend Giardia lamblia EIA). The test with the Meridian Merifluor Cryptosporidium/Giardia kit was used as the reference method. In various combinations, 60 specimens positive for Giardia, 60 specimens positive for Cryptosporidium, 40 specimens positive for a Giardia-Cryptosporidium mix, and 50 negative fecal specimens were tested. Different species (nine protozoa, three coccidia, one microsporidium, five nematodes, three cestodes, and one trematode) were included in the negative specimens. The sensitivity of EIA for Giardia ranged from 94% (Alexon) to 99% (Trend and Cambridge); the specificity was 100% with all EIA kits tested. The sensitivity of EIA for Cryptosporidium ranged from 98% (Alexon) to 99% (Meridian Premier); specificities were 100%. All DFA results were in agreement, with 100% sensitivity and specificity; however, the TechLab reagents resulted in fluorescence intensity that was generally one level below that seen with the reagents used in the reference method. In addition to sensitivity and specificity, factors such as cost, simplicity, ease of interpretation of results (color, intensity of fluorescence), equipment, available personnel, and number of tests ordered are also important considerations prior to kit selection. PMID:9163474

  3. Statistical assessment of DNA extraction reagent lot variability in real-time quantitative PCR

    USGS Publications Warehouse

    Bushon, R.N.; Kephart, C.M.; Koltun, G.F.; Francy, D.S.; Schaefer, F. W.; Lindquist, H.D. Alan

    2010-01-01

    Aims: The aim of this study was to evaluate the variability in lots of a DNA extraction kit using real-time PCR assays for Bacillus anthracis, Francisella tularensis and Vibrio cholerae. Methods and Results: Replicate aliquots of three bacteria were processed in duplicate with three different lots of a commercial DNA extraction kit. This experiment was repeated in triplicate. Results showed that cycle threshold values were statistically different among the different lots. Conclusions: Differences in DNA extraction reagent lots were found to be a significant source of variability for qPCR results. Steps should be taken to ensure the quality and consistency of reagents. Minimally, we propose that standard curves should be constructed for each new lot of extraction reagents, so that lot-to-lot variation is accounted for in data interpretation. Significance and Impact of the Study: This study highlights the importance of evaluating variability in DNA extraction procedures, especially when different reagent lots are used. Consideration of this variability in data interpretation should be an integral part of studies investigating environmental samples with unknown concentrations of organisms. ?? 2010 The Society for Applied Microbiology.

  4. Role of the Neddylation Enzyme Uba3, A New Estrogen Receptor Corepressor in Breast Cancer

    DTIC Science & Technology

    2006-09-01

    cells acquire ICI 182,780 resistance while retaining expres- sion of ER. MATERIALS AND METHODS Materials The following antibodies and reagents were used...protein assay kit; FBS and csFBS (Hy- Clone Laboratories, Inc., Logan, UT); LipofectAMINE Plus Reagent , geneticin, and other cell culture reagents were...plasmid DNA (adjusted by corresponding empty vectors) by using LipofectAMINE Plus Reagent according to the manufacturer’s guidelines. Five hours later

  5. Comparison of EPA Method 1615 RT-qPCR Assays in Standard and Kit Format

    EPA Science Inventory

    EPA Method 1615 contains protocols for measuring enterovirus and norovirus by reverse transcription quantitative polymerase chain reaction. A commercial kit based upon these protocols was designed and compared to the method's standard approach. Reagent grade, secondary effluent, ...

  6. Evaluation of Direct PCR Amplification Using Various Swabs and Washing Reagents.

    PubMed

    Altshuler, Hallie; Roy, Reena

    2015-11-01

    DNA profiles were generated via direct amplification from blood and saliva samples deposited on various types of swab substrates. Each of the six non-FTA substrates used in this research was punched with a Harris 1.2 mm puncher. After 0.1 μL of blood or 0.5 μL saliva, samples were deposited on each of these punches, samples were pretreated with one of four buffers and washing reagents. Amplification was performed using direct and nondirect autosomal and Y-STR kits. Autosomal and Y-STR profiles were successfully generated from most of these substrates when pretreated with buffer or washing reagents. Concordant profiles were obtained within and between the six substrates, the six amplification kits, and all four reagents. The direct amplification of substrates which do not contain lysing agent would be beneficial to the forensic community as the procedure can be used on evidence samples commonly found at crime scenes. © 2015 American Academy of Forensic Sciences.

  7. Improving clinical laboratory efficiency: a time-motion evaluation of the Abbott m2000 RealTime and Roche COBAS AmpliPrep/COBAS TaqMan PCR systems for the simultaneous quantitation of HIV-1 RNA and HCV RNA.

    PubMed

    Amendola, Alessandra; Coen, Sabrina; Belladonna, Stefano; Pulvirenti, F Renato; Clemens, John M; Capobianchi, M Rosaria

    2011-08-01

    Diagnostic laboratories need automation that facilitates efficient processing and workflow management to meet today's challenges for expanding services and reducing cost, yet maintaining the highest levels of quality. Processing efficiency of two commercially available automated systems for quantifying HIV-1 and HCV RNA, Abbott m2000 system and Roche COBAS Ampliprep/COBAS TaqMan 96 (docked) systems (CAP/CTM), was evaluated in a mid/high throughput workflow laboratory using a representative daily workload of 24 HCV and 72 HIV samples. Three test scenarios were evaluated: A) one run with four batches on the CAP/CTM system, B) two runs on the Abbott m2000 and C) one run using the Abbott m2000 maxCycle feature (maxCycle) for co-processing these assays. Cycle times for processing, throughput and hands-on time were evaluated. Overall processing cycle time was 10.3, 9.1 and 7.6 h for Scenarios A), B) and C), respectively. Total hands-on time for each scenario was, in order, 100.0 (A), 90.3 (B) and 61.4 min (C). The interface of an automated analyzer to the laboratory workflow, notably system set up for samples and reagents and clean up functions, are as important as the automation capability of the analyzer for the overall impact to processing efficiency and operator hands-on time.

  8. Automated homogeneous liposome immunoassay systems for anticonvulsant drugs.

    PubMed

    Kubotsu, K; Goto, S; Fujita, M; Tuchiya, H; Kida, M; Takano, S; Matsuura, S; Sakurabayashi, I

    1992-06-01

    We developed automated homogeneous immunoassays, based on immunolysis of liposomes, for measuring phenytoin, phenobarbital, and carbamazepine from serum. Liposome lysis was detected spectrophotometrically from entrapped glucose-6-phosphate dehydrogenase activity. The procedure was fully automated on a routine automated clinical analyzer. Within-run, between-run, dilution, and recovery tests showed good accuracies and reproducibilities. Bilirubin, hemoglobin, triglycerides, and Intrafat did not affect assay results. The results obtained by liposome immunoassays for phenytoin, phenobarbital, and carbamazepine correlated well with those obtained by enzyme-multiplied immunoassay (Syva EMIT) kits (r = 0.995, 0.986, and 0.988, respectively) and fluorescence polarization immunoassay (Abbott TDx) kits (r = 0.990, 0.991, and 0.975, respectively). The proposed method should be useful for monitoring anticonvulsant drug concentrations in blood.

  9. Spot test kit for explosives detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pagoria, Philip F; Whipple, Richard E; Nunes, Peter J

    An explosion tester system comprising a body, a lateral flow membrane swab unit adapted to be removeably connected to the body, a first explosives detecting reagent, a first reagent holder and dispenser operatively connected to the body, the first reagent holder and dispenser containing the first explosives detecting reagent and positioned to deliver the first explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body, a second explosives detecting reagent, and a second reagent holder and dispenser operatively connected to the body, the second reagent holder and dispensermore » containing the second explosives detecting reagent and positioned to deliver the second explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body.« less

  10. Kits for Characterization of Chromosomal Inversions Using Probes

    NASA Technical Reports Server (NTRS)

    Ray, F. Andrew (Inventor)

    2017-01-01

    A kit for the characterization of chromosomal inversions using single-stranded probes that are either all identical or all complementary to a single-stranded chromatid is described. Reporter species are attached to oligonucleotide strands designed such that they may hybridize to portions of only one of a pair of single-stranded sister chromatids which may be prepared by the CO-FISH procedure. If an inversion has occurred, these marker probes will be detected on the second sister chromatid at the same location as the inversion on the first chromatid. The kit includes non-repetitive probes that are either all identical or all complementary to at least a portion of a target DNA sequence of only one DNA strand of only one chromatid and may in some embodiments include reagents suitable for performing CO-FISH and/or reagents for hybridizing the probes to the target DNA sequence.

  11. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    PubMed

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  12. The use of reference change values in clinical laboratories.

    PubMed

    Bugdayci, Guler; Oguzman, Hamdi; Arattan, Havva Yasemin; Sasmaz, Guler

    2015-01-01

    The use of Reference Change Values (RCV) has been advocated as very useful for monitoring individuals. Most of these are performed for monitoring individuals in acute situations and for following up the improvement or deterioration of chronic diseases. In our study, we aimed at evaluating the RCV calculation for 24 clinical chemistry analytes widely used in clinical laboratories and the utilization of this data. Twenty-four serum samples were analyzed with Abbott kits (Abbott Laboratories, Abbott Park, IL, USA), manufactured for use with the Architect c8000 (Abbott Laboratories, Abbott Park, IL, USA) auto-analyzer. We calculated RCV using the following formula: RCV = Z x 2 1/2x (CVA2 + CVw2)1/2. Four reference change values (RCV) were calculated for each analyte using four statistical probabilities (0.95, and 0.99, unidirectional and bidirectional). Moreover, by providing an interval after identifying upper and lower limits with the Reference Change Factor (RCF), serially measured tests were calculated by using two formulas: exp (Z x 2 1/2 x (CV(A)2 + CVw2)½/100) for RCF(UP) and (1/RCF(UP)) for RCF(DOWN). RCVs of these analytes were calculated as 14.63% for glucose, 29.88% for urea, 17.75% for ALP, 53.39% for CK, 46.98% for CK-MB, 21.00% amylase, 8.00% for total protein, 8.70% for albumin, 51.08% for total bilirubin, 86.34% for direct bilirubin, 6.40% for calcium, 15.03% for creatinine, 21.47% for urate, 14.19% for total cholesterol, 46.62% for triglyceride, 20.51% for HDL-cholesterol, 29.59% for AST, 46.31% for ALT, 31.54% for GGT, 20.92% for LDH, 19.75% for inorganic phosphate, 3.05% for sodium, 11.75% for potassium, 4.44% for chloride (RCV, p < 0.05, unidirectionally). We suggest using RCV as well as using population-based reference intervals in clinical laboratories. RCV could be available as a tool for making clinical decision, especially when monitoring individuals.

  13. Recommendations for adaptation and validation of commercial kits for biomarker quantification in drug development.

    PubMed

    Khan, Masood U; Bowsher, Ronald R; Cameron, Mark; Devanarayan, Viswanath; Keller, Steve; King, Lindsay; Lee, Jean; Morimoto, Alyssa; Rhyne, Paul; Stephen, Laurie; Wu, Yuling; Wyant, Timothy; Lachno, D Richard

    2015-01-01

    Increasingly, commercial immunoassay kits are used to support drug discovery and development. Longitudinally consistent kit performance is crucial, but the degree to which kits and reagents are characterized by manufacturers is not standardized, nor are the approaches by users to adapt them and evaluate their performance through validation prior to use. These factors can negatively impact data quality. This paper offers a systematic approach to assessment, method adaptation and validation of commercial immunoassay kits for quantification of biomarkers in drug development, expanding upon previous publications and guidance. These recommendations aim to standardize and harmonize user practices, contributing to reliable biomarker data from commercial immunoassays, thus, enabling properly informed decisions during drug development.

  14. Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.

    PubMed

    Wilson, D H; Bogacz, J P; Forsythe, C M; Turk, P J; Lane, T L; Gates, R C; Brandt, D R

    1993-10-01

    We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuring the quenching by heme of the static fluorescence from an added fluorophore. The assay is standardized to report both percent total glycohemoglobin (%GHb) and percent hemoglobin A1c (%HbA1c). Glucose, bilirubin, triglycerides, labile fraction, and hemoglobin variants do not interfere in the assay. Within- and between-run CVs are approximately 4-5%, with total CVs of approximately 6.5%. Highly significant linear correlations (r > 0.97) were obtained in comparison studies with two major assay methodologies. The time to obtain one result is approximately 10 min (including assay of a control), 56 min for 22 results. We describe the development, standardization, and validation of this new method.

  15. Validating urinary measurement of beta-2-microglobulin with a Roche reagent kit designed for serum measurements.

    PubMed

    Chan, Pak Cheung R; Kulasingam, Vathany; Lem-Ragosnig, Bonny

    2012-11-01

    To validate the use of a Roche serum beta-2-microglobulin (B2MG) kit for urinary B2MG measurements, and to establish reference limits for urinary B2MG/creatinine ratio from healthy individuals. The Roche B2MG Tina-Quant serum kit was used to measure urinary B2MG immunoturbidimetrically. Using human urine as a diluent, the B2MG method was linear from 73-2156 μg/L. The imprecision on a commercially available urine QC was 4.4% at a concentration of 380 μg/L. Limit of quantification at <20% CV was 40 μg/L. Method comparison with Immulite 2000 (Siemens) yielded slope=1.180 (95% CI 1.14-1.22), intercept=11.5 (95% CI -3.6-26.6), SEE=27.6 and r=0.99 (n=26) by the Deming regression analysis. The upper reference limit of B2MG/creatinine ratio determined from 195 healthy adults was 29 μg/mmol (97.5th centile). The serum B2MG Tina Quant reagent kit is acceptable to measure urinary B2MG. Copyright © 2012. Published by Elsevier Inc.

  16. Evaluation of dried blood spot as an alternative sample collection method for hepatitis C virus RNA quantitation and genotyping using a commercial system.

    PubMed

    Mahajan, Supriya; Choudhary, Manish Chandra; Kumar, Guresh; Gupta, Ekta

    2018-06-01

    Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log 10  IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log 10  IU/ml was comparable to DBS (3.93; range 0-7.24) log 10  IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r 2  = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.

  17. An evaluation of direct PCR amplification

    PubMed Central

    Hall, Daniel E.; Roy, Reena

    2014-01-01

    Aim To generate complete DNA profiles from blood and saliva samples deposited on FTA® and non-FTA® paper substrates following a direct amplification protocol. Methods Saliva samples from living donors and blood samples from deceased individuals were deposited on ten different FTA® and non-FTA® substrates. These ten paper substrates containing body fluids were kept at room temperature for varying lengths of time ranging from one day to approximately one year. For all assays in this research, 1.2 mm punches were collected from each substrate containing one type of body fluid and amplified with reagents provided in the nine commercial polymerase chain reaction (PCR) amplification kits. The substrates were not subjected to purification reagent or extraction buffer prior to amplification. Results Success rates were calculated for all nine amplification kits and all ten substrates based on their ability to yield complete DNA profiles following a direct amplification protocol. Six out of the nine amplification kits, and four out of the ten paper substrates had the highest success rates overall. Conclusion The data show that it is possible to generate complete DNA profiles following a direct amplification protocol using both standard (non-direct) and direct PCR amplification kits. The generation of complete DNA profiles appears to depend more on the success of the amplification kit rather than the than the FTA®- or non-FTA®-based substrates. PMID:25559837

  18. Reagent and labor cost optimization through automation of fluorescence in situ hybridization (FISH) with the VP 2000: an Italian case study.

    PubMed

    Zanatta, Lucia; Valori, Laura; Cappelletto, Eleonora; Pozzebon, Maria Elena; Pavan, Elisabetta; Dei Tos, Angelo Paolo; Merkle, Dennis

    2015-02-01

    In the modern molecular diagnostic laboratory, cost considerations are of paramount importance. Automation of complex molecular assays not only allows a laboratory to accommodate higher test volumes and throughput but also has a considerable impact on the cost of testing from the perspective of reagent costs, as well as hands-on time for skilled laboratory personnel. The following study tracked the cost of labor (hands-on time) and reagents for fluorescence in situ hybridization (FISH) testing in a routine, high-volume pathology and cytogenetics laboratory in Treviso, Italy, over a 2-y period (2011-2013). The laboratory automated FISH testing with the VP 2000 Processor, a deparaffinization, pretreatment, and special staining instrument produced by Abbott Molecular, and compared hands-on time and reagent costs to manual FISH testing. The results indicated significant cost and time saving when automating FISH with VP 2000 when more than six FISH tests were run per week. At 12 FISH assays per week, an approximate total cost reduction of 55% was observed. When running 46 FISH specimens per week, the cost saving increased to 89% versus manual testing. The results demonstrate that the VP 2000 processor can significantly reduce the cost of FISH testing in diagnostic laboratories. © 2014 Society for Laboratory Automation and Screening.

  19. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  20. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  1. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  2. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  3. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  4. 77 FR 55504 - Manufacturer of Controlled Substances; Notice of Registration; Research Triangle Institute

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-10

    ... classes of controlled substances: Drug Schedule Marihuana (7360) I Cocaine (9041) II The Institute will manufacture marihuana, and cocaine derivatives for use by their customers in analytical kits, reagents, and...

  5. Multilaboratory comparison of hepatitis C virus viral load assays.

    PubMed

    Caliendo, A M; Valsamakis, A; Zhou, Y; Yen-Lieberman, B; Andersen, J; Young, S; Ferreira-Gonzalez, A; Tsongalis, G J; Pyles, R; Bremer, J W; Lurain, N S

    2006-05-01

    We report a multilaboratory evaluation of hepatitis C virus (HCV) viral load assays to determine their linear range, reproducibility, subtype detection, and agreement. A panel of HCV RNA samples ranging in nominal concentration from 1.0 to 7.0 log10 IU/ml was constructed by diluting a clinical specimen (genotype 1b). Replicates of the panel were tested in multiple laboratories using the Abbott TaqMan analyte-specific reagent (Abbott reverse transcription-PCR [RT-PCR]), Roche TaqMan RUO (Roche RT-PCR), Roche Amplicor Monitor HCV 2.0 (Roche Monitor), and Bayer VERSANT HCV RNA 3.0 (Bayer bDNA) assays. Bayer bDNA-negative specimens were tested reflexively using the Bayer VERSANT HCV RNA qualitative assay (Bayer TMA). Abbott RT-PCR and Roche RT-PCR detected all 28 replicates with a concentration of 1.0 log10 IU/ml and were linear to 7.0 log10 IU/ml. Roche Monitor and Bayer bDNA detected 27 out of 28 and 13 out of 28 replicates, respectively, of 3.0 log10 IU/ml. Bayer TMA detected all seven replicates with 1.0 log10 IU/ml. Bayer bDNA was the most reproducible of the four assays. The mean viral load values for panel members in the linear ranges of the assays were within 0.5 log10 for the different tests. Eighty-nine clinical specimens of various genotypes (1 through 4) were tested in the Bayer bDNA, Abbott RT-PCR, and Roche RT-PCR assays. For Abbott RT-PCR, mean viral load values were 0.61 to 0.96 log10 greater than the values for Bayer bDNA assay for samples with genotype 1, 2, or 3 samples and 0.08 log10 greater for genotype 4 specimens. The Roche RT-PCR assay gave mean viral load values that were 0.28 to 0.82 log10 greater than those obtained with the Bayer bDNA assay for genotype 1, 2, and 3 samples. However, for genotype 4 samples the mean viral load value obtained with the Roche RT-PCR assay was, on average, 0.15 log10 lower than that of the Bayer bDNA. Based on these data, we conclude that the sensitivity and linear range of the Abbott and Roche RT-PCR assays enable them to be used for HCV diagnostics and therapeutic monitoring. However, the differences in the viral load values obtained with the different assays underscore the importance of using one assay when monitoring response to therapy.

  6. Validation of a reaction volume reduction protocol for analysis of Y chromosome haplotypes targeting DNA databases.

    PubMed

    Souza, C A; Oliveira, T C; Crovella, S; Santos, S M; Rabêlo, K C N; Soriano, E P; Carvalho, M V D; Junior, A F Caldas; Porto, G G; Campello, R I C; Antunes, A A; Queiroz, R A; Souza, S M

    2017-04-28

    The use of Y chromosome haplotypes, important for the detection of sexual crimes in forensics, has gained prominence with the use of databases that incorporate these genetic profiles in their system. Here, we optimized and validated an amplification protocol for Y chromosome profile retrieval in reference samples using lesser materials than those in commercial kits. FTA ® cards (Flinders Technology Associates) were used to support the oral cells of male individuals, which were amplified directly using the SwabSolution reagent (Promega). First, we optimized and validated the process to define the volume and cycling conditions. Three reference samples and nineteen 1.2 mm-diameter perforated discs were used per sample. Amplification of one or two discs (samples) with the PowerPlex ® Y23 kit (Promega) was performed using 25, 26, and 27 thermal cycles. Twenty percent, 32%, and 100% reagent volumes, one disc, and 26 cycles were used for the control per sample. Thereafter, all samples (N = 270) were amplified using 27 cycles, one disc, and 32% reagents (optimized conditions). Data was analyzed using a study of equilibrium values between fluorophore colors. In the samples analyzed with 20% volume, an imbalance was observed in peak heights, both inside and in-between each dye. In samples amplified with 32% reagents, the values obtained for the intra-color and inter-color standard balance calculations for verification of the quality of the analyzed peaks were similar to those of samples amplified with 100% of the recommended volume. The quality of the profiles obtained with 32% reagents was suitable for insertion into databases.

  7. 77 FR 1396 - Procurement of Commodities and Services Financed by USAID Federal Program Funds.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    ... Agriculture Commodities, has been revised to state that USAID provides a list of restricted agricultural... salts, biologicals, and some in-vitro diagnostic reagents/test kits; but does not include devices or...

  8. [Detection of rubella virus RNA in clinical material by real time polymerase chain reaction method].

    PubMed

    Domonova, É A; Shipulina, O Iu; Kuevda, D A; Larichev, V F; Safonova, A P; Burchik, M A; Butenko, A M; Shipulin, G A

    2012-01-01

    Development of a reagent kit for detection of rubella virus RNA in clinical material by PCR-RT. During development and determination of analytical specificity and sensitivity DNA and RNA of 33 different microorganisms including 4 rubella strains were used. Comparison of analytical sensitivity of virological and molecular-biological methods was performed by using rubella virus strains Wistar RA 27/3, M-33, "Orlov", Judith. Evaluation of diagnostic informativity of rubella virus RNAisolation in various clinical material by PCR-RT method was performed in comparison with determination of virus specific serum antibodies by enzyme immunoassay. A reagent kit for the detection of rubella virus RNA in clinical material by PCR-RT was developed. Analytical specificity was 100%, analytical sensitivity - 400 virus RNA copies per ml. Analytical sensitivity of the developed technique exceeds analytical sensitivity of the Vero E6 cell culture infection method in studies of rubella virus strains Wistar RA 27/3 and "Orlov" by 11g and 31g, and for M-33 and Judith strains is analogous. Diagnostic specificity is 100%. Diagnostic specificity for testing samples obtained within 5 days of rash onset: for peripheral blood sera - 20.9%, saliva - 92.5%, nasopharyngeal swabs - 70.1%, saliva and nasopharyngeal swabs - 97%. Positive and negative predictive values of the results were shown depending on the type of clinical material tested. Application of reagent kit will allow to increase rubella diagnostics effectiveness at the early stages of infectious process development, timely and qualitatively perform differential diagnostics of exanthema diseases, support tactics of anti-epidemic regime.

  9. The Abbott Architect c8000: analytical performance and productivity characteristics of a new analyzer applied to general chemistry testing.

    PubMed

    Pauli, Daniela; Seyfarth, Michael; Dibbelt, Leif

    2005-01-01

    Applying basic potentiometric and photometric assays, we evaluated the fully automated random access chemistry analyzer Architect c8000, a new member of the Abbott Architect system family, with respect to both its analytical and operational performance and compared it to an established high-throughput chemistry platform, the Abbott Aeroset. Our results demonstrate that intra- and inter-assay imprecision, inaccuracy, lower limit of detection and linear range of the c8000 generally meet actual requirements of laboratory diagnosis; there were only rare exceptions, e.g. assays for plasma lipase or urine uric acid which apparently need to be improved by additional rinsing of reagent pipettors. Even with plasma exhibiting CK activities as high as 40.000 U/l, sample carryover by the c8000 could not be detected. Comparison of methods run on the c8000 and the Aeroset revealed correlation coefficients of 0.98-1.00; if identical chemistries were applied on both analyzers, slopes of regression lines approached unity. With typical laboratory workloads including 10-20% STAT samples and up to 10% samples with high analyte concentrations demanding dilutional reruns, steady-state throughput numbers of 700 to 800 tests per hour were obtained with the c8000. The system generally responded to STAT orders within 2 minutes yielding analytical STAT order completion times of 5 to 15 minutes depending on the type and number of assays requested per sample. Due to its extended test and sample processing capabilities and highly comfortable software, the c8000 may meet the varying needs of clinical laboratories rather well.

  10. Evaluation of Gentian cystatin C reagent on Abbott Ci8200 and calculation of glomerular filtration rate expressed in mL/min/1.73 m(2) from the cystatin C values in mg/L.

    PubMed

    Flodin, M; Jonsson, A-S; Hansson, L-O; Danielsson, L-A; Larsson, A

    2007-01-01

    Estimation of the glomerular filtration rate (GFR) is essential when evaluating patients with kidney disease and treating patients with drugs eliminated from the circulation by the kidneys. Cystatin C has been shown in several studies to be superior to creatinine in the estimation of GFR. At our hospitals, there is an increasing demand for cystatin C and at present we perform approximately 1500 cystatin C analyses a month. We thus need the assay available 24 h/day and to have it on our routine chemistry instrument to minimize handling time per test and time to reported test results. We have evaluated a new cystatin C immunoassay from Gentian (Gentian, Moss, Norway) on Architect ci8200 (Abbott Laboratories, Abbott Park, Ill., USA). A prerequisite at our hospital is that cystatin C results are reported as a calculated GFR in mL/min/1.73 m(2), so we also made a comparison with iohexol clearance. The Gentian cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, Ill., USA) and good inter-laboratory concordance. The assay has very low total imprecision, good linearity and strong correlation with iohexol clearance (R (2) = 0.956). The equation for the correlation curve is: y = 79.901x(-1.4389). There was low inter-laboratory variation between the three laboratories involved in the cystatin C evaluation, and thus all three laboratories can use the same equation for calculating the estimated GFR.

  11. Multicenter Evaluation of Cystatin C Measurement after Assay Standardization.

    PubMed

    Bargnoux, Anne-Sophie; Piéroni, Laurence; Cristol, Jean-Paul; Kuster, Nils; Delanaye, Pierre; Carlier, Marie-Christine; Fellahi, Soraya; Boutten, Anne; Lombard, Christine; González-Antuña, Ana; Delatour, Vincent; Cavalier, Etienne

    2017-04-01

    Since 2010, a certified reference material ERM-DA471/IFCC has been available for cystatin C (CysC). This study aimed to assess the sources of uncertainty in results for clinical samples measured using standardized assays. This evaluation was performed in 2015 and involved 7 clinical laboratories located in France and Belgium. CysC was measured in a panel of 4 serum pools using 8 automated assays and a candidate isotope dilution mass spectrometry reference measurement procedure. Sources of uncertainty (imprecision and bias) were evaluated to calculate the relative expanded combined uncertainty for each CysC assay. Uncertainty was judged against the performance specifications derived from the biological variation model. Only Siemens reagents on the Siemens systems and, to a lesser extent, DiaSys reagents on the Cobas system, provided results that met the minimum performance criterion calculated according to the intraindividual and interindividual biological variations. Although the imprecision was acceptable for almost all assays, an increase in the bias with concentration was observed for Gentian reagents, and unacceptably high biases were observed for Abbott and Roche reagents on their own systems. This comprehensive picture of the market situation since the release of ERM-DA471/IFCC shows that bias remains the major component of the combined uncertainty because of possible problems associated with the implementation of traceability. Although some manufacturers have clearly improved their calibration protocols relative to ERM-DA471, most of them failed to meet the criteria for acceptable CysC measurements. © 2016 American Association for Clinical Chemistry.

  12. Direct Y-STR amplification of body fluids deposited on commonly found crime scene substrates.

    PubMed

    Dargay, Amanda; Roy, Reena

    2016-04-01

    Body fluids detected on commonly found crime scene substrates require extraction, purification and quantitation of DNA prior to amplification and generation of short tandem repeat (STR) DNA profiles. In this research Y-STR profiles were generated via direct amplification of blood and saliva deposited on 12 different substrates. These included cigarette butts, straws, grass, leaves, woodchips and seven different types of fabric. After depositing either 0.1 μL of blood or 0.5 μL of saliva, each substrate containing the dry body fluid stain was punched using a Harris 1.2 mm micro-punch. Each of these punched substrates, a total of 720 samples, containing minute amount of blood or saliva was either amplified directly without any pre-treatment, or was treated with one of the four washing reagents or buffer. In each of these five experimental groups the substrates containing the body fluid remained in the amplification reagent during the thermal cycling process. Each sample was amplified with the three direct Y-STR amplification kits; AmpFℓSTR(®) Yfiler(®) Direct, Yfiler(®) Plus Amplification Kits and the PowerPlex(®) Y23 System. Complete and concordant Y-STR profiles were successfully obtained from most of these 12 challenging crime scene objects when the stains were analyzed by at least one of the five experimental groups. The reagents and buffer were interchangeable among the three amplification kits, however, pre-treatment with these solutions did not appear to enhance the quality or the number of the full profiles generated with direct amplification. This study demonstrates that blood and saliva deposited on these simulated crime scene objects can be amplified directly. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  13. Development of a mercury detection kit based on melamine-functionalized gold nanoparticles.

    PubMed

    Liu, Guoyan; Ren, Huipeng; Guan, Yuyu; Dai, Ronghua; Chai, Chunyan

    2015-01-01

    A fast and simple mercury detection kit was developed based on melamine-functionalized gold nanoparticles (GNPs). The detection kit contained reagent 1 (GNPs), reagent 2 (melanine), a reaction cuvette with four separated cells, a colorimetric card and a plastic pipette. The GNPs were prepared by a citrate reduction of HAuCl4. A proper amount of melamine was applied to functionalize the GNPs. The complex reaction took place in the present of Hg(2+) in the test samples, leading to the combination of Hg(2+) with the C=N group of melamine located on the surface of the GNPs. This reaction resulted in damage to the stability of colloid gold, and the aggregation of GNPs occurred. Different color changes (from claret-red to lilac, purple and plum) were displayed with different concentrations of Hg(2+) in the test samples. It was very easy and convenient to determine the amount of mercury ion by the naked eye. The advantages of this methodology are listed as follows: a short detecting time (within 10 min), a high specificity (no significant interference was indicated upon adding a certain amount of Cu(2+), Pb(2+), Zn(2+), Mg(2+), Cd(2+) and Fe(2+)), high sensitivity with a detection limit of 0.01 mg L(-1) , easy operation and practical on-site use.

  14. Comparison of RNA Isolation Methods From Insect Larvae

    PubMed Central

    Ridgeway, J. A.; Timm, A. E.

    2014-01-01

    Abstract Isolating RNA from insects is becoming increasingly important in molecular entomology. Four methods including three commercial kits RNeasy Mini Kit (Qiagen), SV Total RNA isolation system (Promega), TRIzol reagent (Invitrogen), and a cetyl trimethylammonium bromide (CTAB)-based method were compared regarding their ability to isolate RNA from whole-body larvae of Thaumatotibia leucotreta (Meyrick), Thanatophilus micans (F.), Plutella xylostella (L.), and Tenebrio molitor (L.). A difference was observed among the four methods regarding RNA quality but not quantity. However, RNA quality and quantity obtained was not dependent on the insect species. The CTAB-based method produced low-quality RNA and the Trizol reagent produced partially degraded RNA, whereas the RNeasy Mini Kit and SV Total RNA isolation system produced RNA of consistently high quality. However, after reverse transcription to cDNA, RNA produced using all four extraction methods could be used to successfully amplify a 708 bp fragment of the cytochrome oxidase I gene. Of the four methods, the SV Total RNA isolation system showed the least amount of DNA contamination with the highest RNA integrity number and is thus recommended for stringent applications where high-quality RNA is required. This is the first comparison of RNA isolation methods among different insect species and the first to compare RNA isolation methods in insects in the last 20 years. PMID:25527580

  15. Comparative evaluation of two different remineralizing agents on the microhardness of bleached enamel surface: Results of an in vitro study.

    PubMed

    Kaur, Gunpriya; Sanap, Anita U; Aggarwal, Shalini D; Kumar, Tanaya

    2015-01-01

    Various agents are studied for their remineralization potential. To evaluate the effect of GC Tooth Mousse and Toothmin Tooth Cream on microhardness of bleached enamel. In vitro- study. Twenty freshly extracted anterior teeth were cut sagittally and impregnated in cold cure acrylic resin. Specimens were kept in artificial saliva to prevent from dehydration. After measuring baseline hardness, teeth were randomly divided into two groups. Everbrite In - Office Tooth whitening kit (Dentamerica) was used to demineralize the teeth following which hardness was measured again. Teeth in group one (n=10) and group two (n=10) were treated with GC tooth mousse (Recaldent) and Toothmin tooth cream (Abbott Healthcare Pvt.Ltd) daily for seven days and microhardness of enamel surface was measured. Mean, SD, and percentage change in the microhardness were calculated. Student's paired t-test was used to evaluate the signifi cance of change from initial, after bleaching for 5 min and after 1-week remineralization Unpaired't' test was used to compare difference between groups. Microhardness significantly decreased in both groups after bleaching (% change group one: 3.24% group two: 3.26% in group; P<0.01 in both groups). Both products significantly increased mineralization after seven days of treatment (P<0.01). Remineralization was numerically better in Toothmin group (Abbott Healthcare Pvt.Ltd ) compared to GC Mousse(Recaldent) (% change 3.27% vs 6.34%). However, difference was not significant (P >0.05). Both GC Tooth Mousse (Recaldent) and Toothmin Tooth cream (Abbott Healthcare Pvt.Ltd) increase the microhardness of bleached enamel. Toothmin tooth cream is a better agent for increasing microhardness, although difference is not significant.

  16. Deceased tissue donor serology and molecular testing for HIV, hepatitis B and hepatitis C viruses: a lack of cadaveric validated tests.

    PubMed

    Victer, Thayssa Neiva da Fonseca; Dos Santos, Cris Stéphany Rodrigues; Báo, Sônia Nair; Sampaio, Thatiane Lima

    2016-12-01

    Vital to patient safety is the accurate assessment and minimization of risk for human immunodeficiency virus (HIV), Hepatitis C (HCV), and Hepatitis B (HBV) virus transmission by deceased donor organ and tissue transplantation. The pathogens are tested by serological kits based on enzyme-linked immunosorbent assay (ELISA), chemiluminescence (CLIA) and eletrochemiluminescence (ECLIA) immunoassays. Organ transplantation is a highly successful life-saving treatment in Brazil, but the Brazilian Health Surveillance Agency currently mandates that all deceased organ donors are screened for HIV, HCV and HBV following living donor policies. In this review, six ELISA (Wama ® , Bio-Rad ® , Biomerieux ® , DiaSorin ® , Acon Biotech ® and Biokit ® ), three CLIA (Abbott ® , Siemens ® , Diasorin ® ) and one ECLIA (Roche ® ) were utilized for evaluating the effectiveness of those serological tests for deceased donors in Brazil according to manufacturer's guidelines. NAT for HIV, HCV and HBV can assist with detection of pre-seroconversion for those infections, and only Cobas ® TaqScreen MPX ® test, the Tigris System ® Procleix Ultrio Assay ® and the Bio-Manguinhos ® HIV/HCV/HBV NAT are commercially available. Between all the tests, only the manufacturer Abbott ® and Cobas ® TaqScreen MPX ® test are currently validated for cadaver samples.

  17. Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI.

    PubMed

    Kondo, Takashi; Kobayashi, Daisuke; Mochizuki, Maki; Asanuma, Kouichi; Takahashi, Satoshi

    2017-01-01

    Background Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. However, differences in measured values between these new reagents and previously used reagents have not been well studied. In this study, we aimed to compare the values between ARCHITECT High-Sensitive Troponin I ST (newly developed reagents), ARCHITECT Troponin I ST and STACIA CLEIA cardiac troponin I (two previously developed reagent kits). Methods Gel filtration high-performance liquid chromatography was used to analyse the causes of differences in measured values. Results The measured values differed between ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cardiac troponin I reagents (r = 0.82). Cross-reactivity tests using plasma with added skeletal-muscle troponin I resulted in higher reactivity (2.17-3.03%) for the STACIA CLEIA cardiac troponin I reagents compared with that for the ARCHITECT High-Sensitive Troponin I ST reagents (less than 0.014%). In addition, analysis of three representative samples using gel filtration high-performance liquid chromatography revealed reagent-specific differences in the reactivity against each cardiac troponin I complex; this could explain the differences in values observed for some of the samples. Conclusion The newly developed ARCHITECT High-Sensitive Troponin I ST reagents were not affected by the presence of skeletal-muscle troponin I in the blood and may be useful for routine examinations.

  18. Preliminary characterization of digestive enzymes in freshwater mussels

    USGS Publications Warehouse

    Sauey, Blake W.; Amberg, Jon J.; Cooper, Scott T.; Grunwald, Sandra K.; Newton, Teresa J.; Haro, Roger J.

    2015-01-01

    Resource managers lack an effective chemical tool to control the invasive zebra mussel Dreissena polymorpha. Zebra mussels clog water intakes for hydroelectric companies, harm unionid mussel species, and are believed to be a reservoir of avian botulism. Little is known about the digestive physiology of zebra mussels and unionid mussels. The enzymatic profile of the digestive glands of zebra mussels and native threeridge (Amblema plicata) and plain pocketbook mussels (Lampsilis cardium) are characterized using a commercial enzyme kit, api ZYM, and validated the kit with reagent-grade enzymes. A linear correlation was shown for only one of nineteen enzymes, tested between the api ZYM kit and a specific enzyme kit. Thus, the api ZYM kit should only be used to make general comparisons of enzyme presence and to observe trends in enzyme activities. Enzymatic trends were seen in the unionid mussel species, but not in zebra mussels sampled 32 days apart from the same location. Enzymatic classes, based on substrate, showed different trends, with proteolytic and phospholytic enzymes having the most change in relative enzyme activity.

  19. [Application of DNA extraction kit, 'GM quicker' for detection of genetically modified soybeans].

    PubMed

    Sato, Noriko; Sugiura, Yoshitsugu; Tanaka, Toshitsugu

    2012-01-01

    Several DNA extraction methods have been officially introduced to detect genetically modified soybeans, but the choice of DNA extraction kits depend on the nature of the samples, such as grains or processed foods. To overcome this disadvantage, we examined whether the GM quicker kit is available for both grains and processed foods. We compared GM quicker with four approved DNA extraction kits in respect of DNA purity, copy numbers of lectin gene, and working time. We found that the DNA quality of GM quicker was superior to that of the other kits for grains, and the procedure was faster. However, in the case of processed foods, GM quicker was not superior to the other kits. We therefore investigated an unapproved GM quicker 3 kit, which is available for DNA extraction from processed foods, such as tofu and boiled soybeans. The GM quicker 3 kit provided good DNA quality from both grains and processed foods, so we made a minor modification of the GM quicker-based protocol that was suitable for processed foods, using GM quicker and its reagents. The modified method enhanced the performance of GM quicker with processed foods. We believe that GM quicker with the modified protocol is an excellent tool to obtain high-quality DNA from grains and processed foods for detection of genetically modified soybeans.

  20. Development and Certification of Station Development Test Objective (SDTO) Experiment # 15012-U, "Near RealTime Water Quality Monitoring Demonstration for ISS Biocides Using Colorimetric Solid Phase Extraction (CSPE)"

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Shcultz, John R.; Siperko, Lorraine M.; Porter, Marc D,; Lipert, Robert J.; Limardo, Jose G.; McCoy, J. Torin

    2009-01-01

    Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.

  1. [Real-time PCR kits for the detection of the African Swine Fever virus].

    PubMed

    Latyshev, O E; Eliseeva, O V; Grebennikova, T V; Verkhovskiĭ, O A; Tsibezov, V V; Chernykh, O Iu; Dzhailidi, G A; Aliper, T I

    2014-01-01

    The results obtained using the diagnostic kit based on real-time polymerase chain reaction to detect the DNA of the African Swine Fever in the pathological material, as well as in the culture fluid, are presented. A high sensitivity and specificity for detection of the DNA in the organs and tissues of animals was shown to be useful for detection in the European Union referentiality reagent kits for DNA detection by real time PCR of ASFV. More rapid and effective method of DNA extraction using columns mini spin Quick gDNA(TM) MiniPrep was suggested and compared to the method of DNA isolation on the inorganic sorbent. High correlation of the results of the DNA detection of ASFV by real-time PCR and antigen detection results ASFV by competitive ELISA obtained with the ELISA SEROTEST/INGEZIM COMRAC PPA was demonstrated. The kit can be used in the veterinary services for effective monitoring of ASFV to contain, eliminate and prevent further spread of the disease.

  2. Evaluation of Copan FLOQSwab for the molecular detection of Chlamydia trachomatis by Abbott RealTime CT PCR.

    PubMed

    Coorevits, L; Vanscheeuwijck, C; Traen, A; Bingé, L; Ryckaert, I; Padalko, E

    2015-12-01

    We evaluated Copan FLOQSwabs next to Abbott swabs for the detection of Chlamydia trachomatis (CT) by Abbott RealTime PCR. We collected 1062 paired swabs from female sex workers. The study was divided in two arms, according to the order of swab collection. If the Abbott swab was collected first, 501 couples were concordant and two discordant (Abbott negative and Copan positive). If the Copan swab was collected first, 537 couples were concordant and 10 discordant (eight Abbott negative and Copan positive and two Abbott positive and Copan negative). All discordant samples contained low levels of C. trachomatis. Technical issues lead to retesting of 64 Copan and 21 Abbott swabs. Our results show that Copan FLOQSwabs can be used interchangeably with Abbott swabs. While appearing to have an advantage in detecting more positive samples, the use of Copan swabs led to a higher retesting rate due to technical errors.

  3. [Requirement of standardizing anti-HBs assay methods in Japan for HBV infection-preventing strategy--discrepancy of anti-HBs measurements among three different kits widely used in Japan].

    PubMed

    Ogata, Norio

    2006-09-01

    The strategy to eliminate hepatitis B virus (HBV) infection by administrating an HB vaccine is changing worldwide; however, this is not the case in Japan. An important concern about the HBV infection-preventing strategy in Japan may be that the assay methods for the antibody to hepatitis B surface antigen (anti-HBs) are not standardized. The minimum protective anti-HBs titer against HBV infection has been established as 10 mIU/ml by World Health Organization (WHO) -standardized assay methods worldwide, but that is still determined as a "positive" test result by the passive hemagglutination (PHA) method in Japan. We compared anti-HBs measurements in given samples among PHA(Mycell II, Institute of Immunology), chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse, Fujirebio), and chemiluminescent immunoassay (CLIA) (Architect, Abbott), all of which are currently in wide use in Japan. First, anti-HBs measurements in serum from individuals who received a yeast-derived recombinant HB vaccine composed of the major surface protein of either subtype adr or subtype ayw were compared. The results clearly showed that in subtype adr-vaccinees CLIA underestimated the anti-HBs amount compared with CLEIA and PHA, but in ayw-vaccinees, the discordance in the measurements among the three kits was not prominent. Second, anti-HBs measurements in standard or calibration solutions of each assay kit were compared. Surprisingly, CLEIA showed higher measurements in all three kit-associated standard or calibration solutions than CLIA. Thus, the anti-HBs titer of 10 mIU/ml is difficult to introduce in Japan as the minimum protective level against HBV infection. Efforts to standardize anti-HBs assay methods are expected to share international evidence about the HBV infection-preventing strategy.

  4. [Selecting methods of controls concentration for internal quality control and continuity of control chart between different reagent lots for HBsAg qualitative detection].

    PubMed

    Li, Jin-ming; Zheng, Huai-jing; Wang, Lu-nan; Deng, Wei

    2003-04-01

    To establish a model for one choosing controls with a suitable concentration for internal quality control (IQC) with qualitative ELISA detection, and a consecutive plotting method on Levey-Jennings control chart when reagent kit lot is changed. First, a series of control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg respectively were assessed for within-run and between-run precision according to NCCLs EP5 document. Then, a linear regression equation (y=bx + a) with best correlation coefficient (r > 0.99) was established based on S/CO values of the series of control serum. Finally, one could choose controls with S/CO value calculated from the equation (y = bx + a) minus the product of the S/CO value multiplying three-fold between-run CV to be still more than 1.0 for IQC use. For consecutive plotting on Levey-Jennings control chart when ELISA kit lot was changed, the new lot kits were used to detect the same series of HBsAg control serum as above. Then, a new linear regression equation (y2 = b2x2 + a2) with best correlation coefficient was obtained. The old one (y1 =b1x1 + a1) could be obtained based on the mean values from above precision assessment. The S/CO value of a control serum detected by new lot kit could be changed to that detected by old kit lot based on the factor of y2/y1. Therefore, the plotting on primary Levey-Jennings control chart could be continued. The within-run coefficient of variation CV of the ELISA method for control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg were 11.08%, 9.49%, 9.83%, 9.18% and 7.25%, respectively, and between-run CV were 13.25%, 14.03%, 15.11%, 13.29% and 9.92%. The linear regression equation with best correlation coefficient from a test at random was y = 3.509x + 0.180. The suitable concentration of control serum for IQC could be 0.5ng/ml or 1.0ng/ml. The linear regression equation from the old lot and other two new lots of the ELISA kits were y1 = 3.550(x1) + 0.226, y2 = 3.238(x2) +0.388, and y3 =3.428(x3) + 0.148, respectively. Then, the transferring factors of 0.960 (y2/y1) and 0.908 (y3/y1) were obtained. The results shows that the model established for IQC control serum concentration selecting and for consecutive plotting on control chart when the reagent lot is changed is effective and practical.

  5. An illness in the family: Dr. Maude Abbott and her sister, Alice Abbott.

    PubMed

    Brookes, Barbara

    2011-01-01

    This paper explores Maude Abbott's internationally significant career in medicine and her parallel commitment to caring for her sister, Alice Abbott. An examination of Abbott's life reveals the difficulties faced by an ambitious Canadian woman in medicine from the 1890s to the 1920s; difficulties compounded by caring for a sister with a mental illness. The Abbott archive suggests that it was far more difficult for a woman doctor to make the kind of sharp distinction between public and private life that might be expected of professional men.

  6. Comparison of the Abbott Architect i2000 assay, the Roche Modular Analytics E170 assay, and an immunoradiometric assay for serum hepatitis B virus markers.

    PubMed

    Kim, Hyunjung; Oh, Eun-Jee; Kang, Mi-Sook; Kim, Sung Hoon; Park, Yeon-Joon

    2007-01-01

    Serum hepatitis B virus (HBV) markers are the most important data for epidemiological screening and clinical diagnosis of HBV infection, especially in endemic areas. We compared the results of the Roche Modular Analytics E170 assay, the Abbott Architect i2000 assay, and an immunoradiometric assay (IRMA) for HBV surface antigen (HBsAg), anti-HBV surface antigen (anti-HBs), HBV e antigen (HBeAg), and anti-HBV e antigen (anti-HBe). A number of serum samples (264, 263, 224, and 202 for HBsAg, anti-HBs, HBeAg, and anti-HBe, respectively) were studied. For samples giving discrepant results for HBeAg between methods, real-time PCR assays were performed. The concordance rates among the three methods were high for HBsAg (100%) and HBeAg (94.6), but low for anti-HBs (91.6%) and anti-HBe (82.2%). For anti-HBs, which could be measured quantitatively by the Modular E170 and Architect i2000 procedures, discrepant results were observed at low levels of anti-HBs. For anti-HBe, the positive rate was highest with Modular E170 (60.9%) followed by the IRMA kit (54.1%) and Architect i2000 (51.0%). This study shows substantial differences between the assay results by the three methods, which should be taken into account in determinations of serum HBV markers.

  7. Assessment of a method for measuring serum thyroxine by radioimmunoassay, with use of polyethylene glycol precipitation. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farid, N.R.; Kennedy, C.

    We assessed the efficacy of a new thyroxine radioimmunoassay kit (Abbott) in which polyethylene glycol is used to separate bound from free hormone. Mean serum thyroxine was 88 +- 15 (+-SD) ..mu..g/liter for 96 normal persons. Results for hypothyroid and hyperthyroid persons were clearly separated from those for normal individuals. Women taking oral contraceptive preparations showed variable increases in their serum thyroxine values. The coefficient of variation ranged from 1 to 3% within assay and from 5.4 to 11% among different assays. Excellent parallelism was demonstrated between thyroxine values estimated by this method and those obtained either by competitive proteinmore » binding or by a separate radioimmunoassay for the hormone.« less

  8. Undergraduate Virology Exercises Demonstrate Conventional and Real-Time PCR Using Commercially Available HIV Primers and Noninfectious Target

    ERIC Educational Resources Information Center

    Sulzinski, Michael A.; Wasilewski, Melissa A.; Farrell, James C.; Glick, David L.

    2009-01-01

    It is an extraordinary challenge to offer an undergraduate laboratory course in virology that teaches hands-on, relevant molecular biology techniques using nonpathogenic models of human virus detection. To our knowledge, there exists no inexpensive kits or reagent sets that are appropriate for demonstrating real-time PCR (RT-PCR) in an…

  9. Regulation of Neurotransmitter Responses in the Central Nervous System

    DTIC Science & Technology

    1990-02-05

    A~~ C-DSP 6C. ADORtESS tCIY State ad lip CodeA 7b. ADDRESS IYit. Stele end ZIP COO) ~ AJ C 6200 Freeport Centre Boiling Air Force Base P .A1...considered binding (Table 2). significantly different for a p value of :!0.05. Protein concentrations were determined using reagent kits from Bio -Rad (Richmond

  10. [Membrane-filtration immunoassay: reagents, methods and the diagnostic and technical means for detection].

    PubMed

    Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A

    1999-01-01

    The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.

  11. 78 FR 54487 - Abbott Laboratories; Diagnostic-Hematology; Including On-Site Leased Workers From Manpower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-04

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,379] Abbott Laboratories... February 22, 2013, applicable to workers of Abbott Laboratories, Diagnostic--Hematology division, including... Clara, California location of Abbott Laboratories, Diagnostic--Hematology Division. The Department has...

  12. Mkit: A cell migration assay based on microfluidic device and smartphone.

    PubMed

    Yang, Ke; Wu, Jiandong; Peretz-Soroka, Hagit; Zhu, Ling; Li, Zhigang; Sang, Yaoshuo; Hipolito, Jolly; Zhang, Michael; Santos, Susy; Hillier, Craig; de Faria, Ricardo Lobato; Liu, Yong; Lin, Francis

    2018-01-15

    Mobile sensing based on the integration of microfluidic device and smartphone, so-called MS 2 technology, has enabled many applications over recent years, and continues to stimulate growing interest in both research communities and industries. In particular, it has been envisioned that MS 2 technology can be developed for various cell functional assays to enable basic research and clinical applications. Toward this direction, in this paper, we describe the development of a MS 2 -based cell functional assay for testing cell migration (the M kit ). The system is constructed as an integrated test kit, which includes microfluidic chips, a smartphone-based imaging platform, the phone apps for image capturing and data analysis, and a set of reagent and accessories for performing the cell migration assay. We demonstrated that the M kit can effectively measure purified neutrophil and cancer cell chemotaxis. Furthermore, neutrophil chemotaxis can be tested from a drop of whole blood using the M kit with red blood cell (RBC) lysis. The effects of chemoattractant dose and gradient profile on neutrophil chemotaxis were also tested using the M kit . In addition to research applications, we demonstrated the effective use of the M kit for on-site test at the hospital and for testing clinical samples from chronic obstructive pulmonary disease patient. Thus, this developed M kit provides an easy and integrated experimental platform for cell migration related research and potential medical diagnostic applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. PubMed Central

    Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.

    1994-01-01

    A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645

  14. Direct detection of Mycobacterium tuberculosis and drug resistance in respiratory specimen using Abbott Realtime MTB detection and RIF/INH resistance assay.

    PubMed

    Tam, Kingsley King-Gee; Leung, Kenneth Siu-Sing; To, Sabrina Wai-Chi; Siu, Gilman Kit-Hang; Lau, Terrence Chi-Kong; Shek, Victor Chi-Man; Tse, Cindy Wing-Sze; Wong, Samson Sai-Yin; Ho, Pak-Leung; Yam, Wing-Cheong

    2017-10-01

    Abbott RealTime MTB (Abbott-RT) in conjunction with Abbott RealTime MTB RIF/INH Resistance (Abbott-RIF/INH) is a new, high-throughput automated nucleic acid amplification platform (Abbott-MDR) for detection of Mycobacterium tuberculosis complex (MTBC) and the genotypic markers for rifampicin (RIF) and isoniazid (INH) resistance directly from respiratory specimens. This prospective study evaluated the diagnostic performance of this new platform for MTBC and multidrug-resistant tuberculosis (MDR-TB) using 610 sputum specimens in a tuberculosis high-burden setting. Using conventional culture results and clinical background as reference standards, Abbott-RT exhibited an overall sensitivity and specificity of 95.2% and 99.8%, respectively. Genotypic RIF/INH resistance of 178 "MTB detected" specimens was subsequently analyzed by Abbott-RIF/INH. Compared to phenotypic drug susceptibility test results, Abbott-RIF/INH detected resistance genotypic markers in 84.6% MDR-TB, 80% mono-RIF-resistant and 66.7% mono-INH-resistant specimens. Two of the RIF-resistant specimens carried a novel single, nonsense mutation at rpoB Q513 and in silico simulation demonstrated that the truncated RpoB protein failed to bind with other subunits for transcription. Overall, Abbott-MDR platform provided high throughput and reliable diagnosis of MDR-TB within a TB high-burden region. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A cost effective hydrogel test kit for pre and post blast trinitrotoluene.

    PubMed

    Choodum, Aree; Malathong, Khanitta; NicDaeid, Niamh; Limsakul, Wadcharawadee; Wongniramaikul, Worawit

    2016-09-01

    A cost effective hydrogel test kit was successfully developed for the detection of pre- and post-blast trinitrotoluene (TNT). A polyvinyl alcohol (PVA) hydrogel matrix was used to entrap the potassium hydroxide (KOH) colourimetric reagent. The easily portable test kit was fabricated in situ in a small tube to which the sample could be added directly. The test kit was used in conjunction with digital image colourimetry (DIC) to demonstrate the rapid quantitative analysis of TNT in a test soil sample. The built-in digital camera of an iPhone was used to capture digital images of the colourimetric products from the test kit. Red-Green-Blue (RGB) colour data from the digital images of TNT standard solutions were used to establish a calibration graph. The validation of the DIC method indicated excellent inter day precision (0.12-3.60%RSD) and accuracy (93-108% relative accuracy). Post-blast soil samples containing TNT were analysed using the test kit and were in good agreement with spectrophotometric analysis. The intensity of the RGB data from the TNT complex deviated by +6.3%, +5.1%, and -4.9% after storage of the test kits in a freezer for 3 months. The test kit was also reusable for up to 12 times with only -5.4%, +0.3%, and +4.0% deviations. The hydrogel test kit was applied in the detection of trace explosive residues at the scene of the recent Bangkok bombing at the Ratchaprasong intersection and produced positive results for TNT demonstrating its operational field application as a rapid and cost effective quantitative tool for explosive residue analysis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-27

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,201] Abbott Laboratories..., applicable to workers of Abbott Laboratories, Diagnostics Division, including on-site leased workers from... (clerical) were employed on-site at the Irving, Texas location of Abbott Laboratories, Diagnostics Division...

  17. 76 FR 47143 - Approval for Manufacturing Authority, Foreign-Trade Zone 153; Abbott Cardiovascular Systems, Inc...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-04

    ... Authority, Foreign-Trade Zone 153; Abbott Cardiovascular Systems, Inc., (Cardiovascular Devices), Riverside... of Abbott Cardiovascular Systems, Inc., within Sites 11-13 of FTZ 153, located in Riverside County... behalf of Abbott Cardiovascular Systems, Inc., as described in the application and Federal Register...

  18. 77 FR 13232 - Abbott Laboratories; Filing of Food Additive Petition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    .... FDA-2012-F-0138] Abbott Laboratories; Filing of Food Additive Petition AGENCY: Food and Drug... that Abbott Laboratories has filed a petition proposing that the food additive regulations be amended... given that a food additive petition (FAP 2A4788) has been filed by Abbott Laboratories, 3300 Stelzer Rd...

  19. [Automated RNA amplification for the rapid identification of Mycobacterium tuberculosis complex in respiratory specimens].

    PubMed

    Drouillon, V; Houriez, F; Buze, M; Lagrange, P; Herrmann, J-L

    2006-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis complex (MTB) directly on clinical respiratory specimens is essential for a correct management of patients suspected of tuberculosis. For this purpose PCR-based kits are available to detect MTB in respiratory specimen but most of them need at least 4 hours to be completed. New methods, based on TRC method (TRC: Transcription Reverse transcription Concerted--TRCRapid M. Tuberculosis--Tosoh Bioscience, Tokyo, Japon) and dedicated monitor have been developed. A new kit (TRC Rapid M. tuberculosis and Real-time monitor TRCRapid-160, Tosoh Corporation, Japan) enabling one step amplification and real-time detection of MTB 16S rRNA by a combination of intercalative dye oxazole yellow-linked DNA probe and isothermal RNA amplification directly on respiratory specimens has been tested in our laboratory. 319 respiratory specimens were tested in this preliminary study and results were compared to smear and culture. Fourteen had a positive culture for MTB. Among theses samples, smear was positive in 11 cases (78.6%) and TRC process was positive in 8 cases (57.1%). Overall sensitivity of TRC compared to smear positive samples is 73%. Theses first results demonstrated that a rapid identification of MTB was possible (less than 2 processing hours for 14 specimens and about 1 hour for 1 specimen) in most cases of smear positive samples using ready to use reagents for real time detection of MTB rRNA in clinical samples. New pretreatment and extraction reagents kits to increase the stability of the sputum RNA and the extraction efficiency are now tested in our laboratory.

  20. Quantification of Fel d 1 in house dust samples of cat allergic patients by using monoclonal antibody specific to a novel IgE-binding epitope.

    PubMed

    Tasaniyananda, Natt; Tungtrongchitr, Anchalee; Seesuay, Watee; Sakolvaree, Yuwaporn; Aiumurai, Pisinee; Indrawattana, Nitaya; Chaicumpa, Wanpen; Sookrung, Nitat

    2018-03-01

    Avoidance of allergen exposure is an effective measure for preventing naÏve and allergic individuals from sensitization (primary intervention) and disease aggravation (secondary intervention), respectively. Regular monitoring of the allergens in the environment is required for the effective intervention. Thus, there is a need for cost-effective test kits for environmental allergen quantifications. To invent a test kit for quantification of cat major allergen, Fel d 1. A mouse monoclonal antibody (MAb) specific to the newly identified IgE-binding conformational epitope of the cat major allergen (Fel d 1) and rabbit polyclonal IgG to recombinant Fel d 1 were used as allergen capture and detection reagents, respectively. Native Fel d 1 was used in constructing a standard curve. Sixteen of 36 dust samples collected from houses of cat allergic subjects in Bangkok contained Fel d 1 above 0.29 μg/gram of dust which is considered as a novel threshold level for causing cat allergy sensitization or symptoms. Among them, 7 samples contained the allergen exceeding 2.35 μg/gram of dust which is the level that would aggravate asthma. Results of the allergen quantification using the locally made test kit showed strong correlation (r = 0.923) with the allergen quantification using commercialized reagents. The assay using MAb to Fel d 1 IgE-binding epitope of this study has potential application as an economic and practical tool for cat allergy intervention measure especially in localities where health resources are relatively limited.

  1. Validation of ALK/ROS1 Dual Break Apart FISH Probe probe in non-small-cell lung cancer.

    PubMed

    Lim, Sun Min; Chang, Hyun; Cha, Yoon Jin; Liang, Shile; Tai, Yan Chin; Li, Gu; Pestova, Ekaterina; Policht, Frank; Perez, Thomas; Soo, Ross A; Park, Won Young; Kim, Hye Ryun; Shim, Hyo Sup; Cho, Byoung Chul

    2017-09-01

    ALK and ROS1 gene rearrangements are distinct molecular subsets of non-small-cell lung cancer (NSCLC), and they are strong predictive biomarkers of response to ALK/ROS1 inhibitors, such as crizotinib. Thus, it is clinically important to develop an effective screening strategy to detect patients who will benefit from such treatment. In this study, we aimed to validate analytical performance of Vysis ALK/ROS1 Dual Break Apart Probe Kit (RUO) in NSCLC. Study population composed of three patient cohorts with histologically confirmed lung adenocarcinoma (patients with ALK rearrangement, patients with ROS1 rearrangement and patients with wild-type ALK and ROS1). Specimens consisted of 12 ALK-positive, 8 ROS1-positive and 21 ALK/ROS1-wild type formalin-fixed paraffin-embedded samples obtained from surgical resection or excisional biopsy. ALK rearrangement was previously assessed by Vysis ALK Break Apart FISH Probe Kit (Abbott Molecular, Abbot Park, IL, USA) and ROS1 rearrangement was previously assessed by ZytoLight ® SPEC ROS1 Break Apart Probe (ZytoVision, GmbH). All specimens were re-evaluated by Vysis ALK/ROS1 Dual Break Apart Probe Kit. FISH images were scanned on BioView AllegroPlus system and interpreted via BioView SoloWeb remotely. For a total of 41 patient samples, the concordance of the results by Vysis ALK/ROS1 Dual Break Apart Probe Kit was evaluated and compared to the known ALK and ROS1 rearrangement status of the specimen. Of the 12 ALK-positive cases, hybridization with Vysis ALK/ROS1 Dual Break Apart Probe Kit was successful in 10 cases (success rate 10/12, 83%) and of these 10 cases, all showed ALK rearrangement (100% concordance with the results of Vysis ALK Break Apart FISH Probe Kit). Two of the ALK+ cases were excluded due to weak ROS1 signals that could not be enumerated. Of the 8 ROS1-positive cases, 6 cases were successfully evaluated using Vysis ALK/ROS1 Dual Break Apart Probe Kit. The success rate was 75% (6/8), and of these 6 cases, all showed ROS1 rearrangement, giving a 100% concordance with ZytoLight ® SPEC ROS1 Break Apart Probe. Two of the cases were excluded due to weak ROS1 gold signal or high background. In the cohort of 21 wild-type cases, the success rate using Vysis ALK/ROS1 Dual Break Apart FISH Probe Kit was 85% (18/21) and the concordance with ALK and ROS1 probe kit was 100% (18/18). Vysis ALK/ROS1 Dual Break Apart Probe Kit (RUO) can detect ALK and ROS1 rearrangement simultaneously in NSCLC. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Validation of a new ELISA method for in vitro potency testing of hepatitis A vaccines.

    PubMed

    Morgeaux, S; Variot, P; Daas, A; Costanzo, A

    2013-01-01

    The goal of the project was to standardise a new in vitro method in replacement of the existing standard method for the determination of hepatitis A virus antigen content in hepatitis A vaccines (HAV) marketed in Europe. This became necessary due to issues with the method used previously, requiring the use of commercial test kits. The selected candidate method, not based on commercial kits, had already been used for many years by an Official Medicines Control Laboratory (OMCL) for routine testing and batch release of HAV. After a pre-qualification phase (Phase 1) that showed the suitability of the commercially available critical ELISA reagents for the determination of antigen content in marketed HAV present on the European market, an international collaborative study (Phase 2) was carried out in order to fully validate the method. Eleven laboratories took part in the collaborative study. They performed assays with the candidate standard method and, in parallel, for comparison purposes, with their own in-house validated methods where these were available. The study demonstrated that the new assay provides a more reliable and reproducible method when compared to the existing standard method. A good correlation of the candidate standard method with the in vivo immunogenicity assay in mice was shown previously for both potent and sub-potent (stressed) vaccines. Thus, the new standard method validated during the collaborative study may be implemented readily by manufacturers and OMCLs for routine batch release but also for in-process control or consistency testing. The new method was approved in October 2012 by Group of Experts 15 of the European Pharmacopoeia (Ph. Eur.) as the standard method for in vitro potency testing of HAV. The relevant texts will be revised accordingly. Critical reagents such as coating reagent and detection antibodies have been adopted by the Ph. Eur. Commission and are available from the EDQM as Ph. Eur. Biological Reference Reagents (BRRs).

  3. Women in History--Grace Abbott: A Leader in Social Reform

    ERIC Educational Resources Information Center

    Hoffman, Shari Cole

    2006-01-01

    This article profiles Grace Abbott, one of the earlier 20th century American women leaders in Progressivism. Abbott's heritage influenced her lifetime commitment to social improvement. She was born on November 17, 1878 in Grand Island, Nebraska into a family of activists. Her Quaker mother, Elizabeth Griffin Abbott, came from an abolitionist…

  4. The Abbott Districts in 2005-06: Progress and Challenges, Spring 2006

    ERIC Educational Resources Information Center

    Hirsch, Lesley

    2006-01-01

    New Jersey's urban--or "Abbott"--schools have improved at the preschool and elementary school level, but lag when it comes to middle and high school performance. These are the key findings of an Abbott Indicators Project report entitled, "The Abbott Districts in 2005-06: Progress and Challenges." The report was prepared by…

  5. Evaluation of a newly developed quantitative determination kit for tumor marker CA15-3 with chemiluminescent assay.

    PubMed

    Li, Peihua; Ye, Huiming; Liu, Jiangwu; Jin, Hongwei; Lin, Yongzhi; Yan, Shuidi; Yu, Yang; Gao, Lei; Xu, Feihai; Zhang, Zhongying

    2018-01-01

    Tumor marker carbohydrate antigen 15-3 (CA15-3) is used as a biomarker to aid to diagnose and monitor the prognosis of breast cancer patients. A new quantitative determination kit for CA15-3 with chemiluminescent assay was developed by Xiamen InnoDx Biotech Co., Ltd, China. Therefore, we conducted the report to evaluate the performance of the kit. According to the "Guiding principles on performance analysis of diagnostic reagents in vitro", the calibration curve, limit of detection, reportable range, accuracy, precision, anti-interference capability, cross-reaction and comparison by measuring EDTA plasma and serum were carried out. In addition, the kit was performed in parallel to electrochemiluminescence immunoassay kit (Roche) to analyze the correlation between the two kits. Regression equation of calibration curve of the kit was Y=0.7914X+4.1032 (R 2 =.990). Limit of detection was 0.0347 U/mL. The reportable range was 0.5-2400 U/mL. Recovery ratio was 100.0%-104.8%. Coefficient of variations (CVs) of within-run and between-run were 4.8%-7.6% and 5.8%-7.4% respectively. No remarkable interferences (all Bias% were less than ±10%) were detected when samples contained hemoglobin ≤183.8 μmol/L, bilirubin ≤340 μmol/L, triglyceride ≤18.1 mmol/L, or rheumatoid factor ≤400 U/mL. No cross-reaction was present in the kit. Moreover, compared with the results from electrochemiluminescence immunoassay kit (Roche) in 345 serum samples, there was a satisfied correlation coefficient of 0.977 (P<.01), and the kit was simultaneously fit for the detection of EDTA plasma and serum samples. The new kit validated satisfactorily, and it can be used for detecting CA15-3 in clinical practice. © 2017 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.

  6. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Societymore » for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.« less

  7. Analytical and clinical evaluation of the Abbott RealTime hepatitis B sequencing assay.

    PubMed

    Huh, Hee Jae; Kim, Ji-Youn; Lee, Myoung-Keun; Lee, Nam Yong; Kim, Jong-Won; Ki, Chang-Seok

    2016-12-01

    Long-term nucleoside analogue (NA) treatment leads to selection for drug-resistant mutations in patients undergoing hepatitis B virus (HBV) therapy. The Abbott RealTime HBV Sequencing assay (Abbott assay; Abbott Molecular Inc., Des Plaines, IL, USA) targets the reverse transcriptase region of the polymerase gene and as such has the ability to detect NA resistance-associated mutations in HBV. We evaluated the analytical performance of the Abbott assay and compared its diagnostic performance to that of a laboratory-developed nested-PCR and sequencing method. The analytical sensitivity of the Abbott assay was determined using a serially-diluted WHO International Standard. To validate the clinical performances of the Abbott assay and the laboratory-developed assay, 89 clinical plasma samples with various levels of HBV DNA were tested using both assays. The limit of detection of the Abbott assay, was 210IU/ml and it successfully detected mutations when the mutant types were present at levels ≥20%. Among 89 clinical specimens, 43 and 42 were amplification positive in the Abbott and laboratory-developed assays, respectively, with 87.6% overall agreement (78/89; 95% confidence interval [CI], 78.6-93.4). The Abbott assay failed to detect the minor mutant populations in two specimens, and therefore overall concordance was 85.3% (76/89), and the kappa value was 0.79 (95% CI, 0.67-0.90). The Abbott assay showed comparable diagnostic performance to laboratory-developed nested PCR followed by direct sequencing, and may be useful as a routine method for detecting HBV NA resistance-associated mutations in clinical laboratory settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Cost of gentamicin assays carried out by microbiology laboratories.

    PubMed Central

    Vacani, P F; Malek, M M; Davey, P G

    1993-01-01

    AIMS--To assess the current range of prices charged for gentamicin assays in United Kingdom laboratories; and to examine the laboratories' likely response to increases or decreases in the demand for the service. METHODS--A postal survey of the 420 members of the Association of Medical Microbiologists was used to establish the range of prices charged for aminoglycoside assays. Additionally, eight private institutions were contacted to determine what the private sector was charging for aminoglycoside assays. Reagent costs in the NHS laboratories were calculated by dividing the total cost of all aminoglycoside assay kits by the number of samples analysed. RESULTS--The NHS and the private institutions both showed a wide price variation. Prices charged to an in-hospital requester for a peak and trough assay ranged from 5.00 pounds to 68.20 pounds (n = 44), and to an external private hospital, under a bulk service contract, from 5.00 pounds to 96.00 pounds (n = 47). Prices charged by private laboratories ranged from 49.00 pounds to 84.00 pounds (n = 8). There was a log linear correlation in the NHS laboratories between the reagent costs per assay and the number of assays performed per year, and most laboratories thought that their price per assay would be sensitive to increases or decreases in demand. Laboratories which had purchased their assay machines had lower reagent costs per assay but higher repair and maintenance costs. Overall, number of assays performed and method of payment for assay machinery only accounted for 44.8% of the observed variation in assay kit costs. CONCLUSIONS--The price range for gentamicin assays in the United Kingdom is wide and is only partially explained by the number of assays performed. Most laboratories believe that they would experience a reduction in unit cost as output increases. The currently offered range of prices is, in part, due to variation in the laboratories' approach to costing the service provided and some laboratories charge prices which do not even cover the cost of assay kits. Overall, we believe that prices charged should be as close as possible to the marginal cost of the tests performed. PMID:8227402

  9. Tracking Progress, Engaging Communities: Abbott Indicators Summary Report--Trenton, New Jersey

    ERIC Educational Resources Information Center

    Hirsch, Lesley; Applewhite-Coney, Erain

    2005-01-01

    Trenton is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Trenton receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Trenton Abbott Indicators Report presents the status of educational…

  10. Tracking Progress, Engaging Communities: Abbott Indicators Summary Report-- Newark, New Jersey

    ERIC Educational Resources Information Center

    Hirsch, Lesley; Applewhite-Coney, Erain

    2005-01-01

    Newark is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Newark receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Newark Abbott Indicators Report presents the status of educational…

  11. Tracking Progress, Engaging Communities: Abbott Indicators Summary Report--Camden, New Jersey

    ERIC Educational Resources Information Center

    Hirsch, Lesley; Applewhite-Coney, Erain

    2005-01-01

    Camden is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Camden receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Camden Abbott Indicators Report presents the status of educational…

  12. Implementing "Abbott v. Burke": A Guide to the 2006 K-12 Abbott Regulations

    ERIC Educational Resources Information Center

    Education Law Center, 2005

    2005-01-01

    Except for school construction, there is no legislation to guide implementation of the programs and reforms ordered by the New Jersey Supreme Court in the landmark "Abbott v. Burke" case. Instead, in its 1998 "Abbott V decision," the Supreme Court directed the Commissioner of Education to provide standards and procedures to…

  13. Tracking Progress, Engaging Communities: Abbott Indicators Technical Report--Camden, New Jersey

    ERIC Educational Resources Information Center

    Hirsch, Lesley; Applewhite-Coney, Erain

    2005-01-01

    Camden is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Camden receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Camden Abbott Indicators Report presents the status of educational…

  14. Tracking Progress, Engaging Communities: Abbott Indicators Technical Report--Trenton, New Jersey

    ERIC Educational Resources Information Center

    Hirsch, Lesley; Applewhite-Coney, Erain

    2005-01-01

    Trenton is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Trenton receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Trenton Abbott Indicators Report presents the status of educational…

  15. Tracking Progress, Engaging Communities: Abbott Indicators Technical Report-- Newark, New Jersey

    ERIC Educational Resources Information Center

    Hirsch, Lesley; Applewhite-Coney, Erain

    2005-01-01

    Newark is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Newark receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Newark Abbott Indicators Report presents the status of educational…

  16. Tracking Progress, Engaging Communities: Abbott Indicators Summary Report--Union City, New Jersey

    ERIC Educational Resources Information Center

    Hirsch, Lesley; Applewhite-Coney, Erain

    2005-01-01

    Union City is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Union City receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Union City Abbott Indicators Report presents the status of…

  17. Tracking Progress, Engaging Communities: Abbott Indicators Technical Report: Union City, New Jersey

    ERIC Educational Resources Information Center

    Applewhite-Coney, Erain; Hirsch, Lesley

    2005-01-01

    Union City is one of 31 urban school districts in New Jersey known as Abbott districts. As an Abbott district, Union City receives funding to equalize its per student general education budget with the most successful suburban districts in the state. Through a series of indicators, the Union City Abbott Indicators Report presents the status of…

  18. "A Prairie Childhood" by Edith Abbott: An Excerpt from "The Children's Champion," a Biography of Grace Abbott

    ERIC Educational Resources Information Center

    Sorensen, John

    2003-01-01

    Grace Abbott's courageous struggles--to protect the rights of immigrants, to increase the role of women in government, and to improve the lives of all children--are filled with adventurous tales of the remarkable human ability to seek out suffering and to do something about it. "A Prairie Childhood" is an excerpt from the Grace Abbott biography…

  19. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    PubMed

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  20. 14 CFR 93.53 - Description of area.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Parkway; thence northerly along Lake Otis Parkway to its intersection with Abbott Road; thence east along Abbott Road to its intersection with Abbott Loop Road; thence north to its intersection with Tudor Road...

  1. Small RNA profiling of low biomass samples: identification and removal of contaminants.

    PubMed

    Heintz-Buschart, Anna; Yusuf, Dilmurat; Kaysen, Anne; Etheridge, Alton; Fritz, Joëlle V; May, Patrick; de Beaufort, Carine; Upadhyaya, Bimal B; Ghosal, Anubrata; Galas, David J; Wilmes, Paul

    2018-05-14

    Sequencing-based analyses of low-biomass samples are known to be prone to misinterpretation due to the potential presence of contaminating molecules derived from laboratory reagents and environments. DNA contamination has been previously reported, yet contamination with RNA is usually considered to be very unlikely due to its inherent instability. Small RNAs (sRNAs) identified in tissues and bodily fluids, such as blood plasma, have implications for physiology and pathology, and therefore the potential to act as disease biomarkers. Thus, the possibility for RNA contaminants demands careful evaluation. Herein, we report on the presence of small RNA (sRNA) contaminants in widely used microRNA extraction kits and propose an approach for their depletion. We sequenced sRNAs extracted from human plasma samples and detected important levels of non-human (exogenous) sequences whose source could be traced to the microRNA extraction columns through a careful qPCR-based analysis of several laboratory reagents. Furthermore, we also detected the presence of artefactual sequences related to these contaminants in a range of published datasets, thereby arguing in particular for a re-evaluation of reports suggesting the presence of exogenous RNAs of microbial and dietary origin in blood plasma. To avoid artefacts in future experiments, we also devise several protocols for the removal of contaminant RNAs, define minimal amounts of starting material for artefact-free analyses, and confirm the reduction of contaminant levels for identification of bona fide sequences using 'ultra-clean' extraction kits. This is the first report on the presence of RNA molecules as contaminants in RNA extraction kits. The described protocols should be applied in the future to avoid confounding sRNA studies.

  2. Undergraduate virology exercises demonstrate conventional and real-time PCR using commercially available HIV primers and noninfectious target.

    PubMed

    Sulzinski, Michael A; Wasilewski, Melissa A; Farrell, James C; Glick, David L

    2009-07-01

    It is an extraordinary challenge to offer an undergraduate laboratory course in virology that teaches hands-on, relevant molecular biology techniques using nonpathogenic models of human virus detection. To our knowledge, there exists no inexpensive kits or reagent sets that are appropriate for demonstrating real-time PCR (RT-PCR) in an undergraduate laboratory course in virology. Here we describe simple procedures for student exercises that demonstrate the PCR detection of an HIV target nucleic acid. Our procedures combine a commercially available kit for conventional PCR with a modification for RT-PCR using the same reagents in the kit, making it possible for an instructor with access to a LightCycler® instrument to implement a relevant student exercise on RT-PCR detection of HIV nucleic acid targets. This combination of techniques is useful for demonstrating and comparing conventional PCR amplification and detection with agarose gel electrophoresis, with real-time PCR over a series of three laboratory periods. The series of laboratory periods also is used to provide the foundation for teaching the concept of PCR primer design, optimization of PCR detection systems, and introduction to nucleic acid queries using NCBI-BLAST to find and identify primers, amplicons, and other potential amplification targets within the HIV viral genome. The techniques were successfully implemented at the Biology 364 undergraduate virology course at the University of Scranton during the Fall 2008 semester. The techniques are particularly targeted to students who intend to pursue either postgraduate technical employment or graduate studies in the molecular life sciences. Copyright © 2009 International Union of Biochemistry and Molecular Biology, Inc.

  3. Measurement of Reactive Oxygen Species in the Culture Media Using Acridan Lumigen PS-3 Assay

    PubMed Central

    Uy, Benedict; McGlashan, Susan R.; Shaikh, Shamim B.

    2011-01-01

    Reactive oxygen species (ROS) are generated continuously during aerobic metabolism. ROS are highly reactive molecules and in excessive amounts, can lead to protein and DNA oxidation, protein cross-linking, and cell death. Cell-culture models provide a valuable tool in understanding the mechanisms that lead to cell death. Accumulation of ROS within cells and/or their release into the culture media are highly cell type-specific. The ability to estimate ROS levels in the culture media is an important step in understanding the mechanisms contributing to disease processes. In this paper, we describe the optimization of a simple method to estimate ROS levels in the culture media using the Acridan Lumigen PS-3 reagent provided in the Amersham ECL Plus kit (GE Healthcare, UK). We have shown that the Acridan Lumigen PS-3 assay generates ROS-specific chemiluminescence in fresh as well as media stored at −20°C, in as little as 10–20 μl of samples. The method was able to detect the dose (of stimulants)- and time (acute and chronic)-dependent changes in ROS levels in media collected from various cell types. Our results suggest that the kit reagents, PBS buffer, and various media did not contribute significantly to the overall chemiluminescence generated in the assay; however, we suggest that the unused medium specific for each cell type should be used as blanks and final readings of test samples normalized against these readings. As this method uses commonly available laboratory equipment and commercially available reagents, we believe this assay is convenient, economical, and specific in estimating ROS released extracellularly into the culture media. PMID:21966257

  4. Measurement of reactive oxygen species in the culture media using Acridan Lumigen PS-3 assay.

    PubMed

    Uy, Benedict; McGlashan, Susan R; Shaikh, Shamim B

    2011-09-01

    Reactive oxygen species (ROS) are generated continuously during aerobic metabolism. ROS are highly reactive molecules and in excessive amounts, can lead to protein and DNA oxidation, protein cross-linking, and cell death. Cell-culture models provide a valuable tool in understanding the mechanisms that lead to cell death. Accumulation of ROS within cells and/or their release into the culture media are highly cell type-specific. The ability to estimate ROS levels in the culture media is an important step in understanding the mechanisms contributing to disease processes. In this paper, we describe the optimization of a simple method to estimate ROS levels in the culture media using the Acridan Lumigen PS-3 reagent provided in the Amersham ECL Plus kit (GE Healthcare, UK). We have shown that the Acridan Lumigen PS-3 assay generates ROS-specific chemiluminescence in fresh as well as media stored at -20°C, in as little as 10-20 μl of samples. The method was able to detect the dose (of stimulants)- and time (acute and chronic)-dependent changes in ROS levels in media collected from various cell types. Our results suggest that the kit reagents, PBS buffer, and various media did not contribute significantly to the overall chemiluminescence generated in the assay; however, we suggest that the unused medium specific for each cell type should be used as blanks and final readings of test samples normalized against these readings. As this method uses commonly available laboratory equipment and commercially available reagents, we believe this assay is convenient, economical, and specific in estimating ROS released extracellularly into the culture media.

  5. Development of an RNA-based kit for easy generation of TCR-engineered lymphocytes to control T-cell assay performance.

    PubMed

    Bidmon, Nicole; Kind, Sonja; Welters, Marij J P; Joseph-Pietras, Deborah; Laske, Karoline; Maurer, Dominik; Hadrup, Sine Reker; Schreibelt, Gerty; Rae, Richard; Sahin, Ugur; Gouttefangeas, Cécile; Britten, Cedrik M; van der Burg, Sjoerd H

    2018-07-01

    Cell-based assays to monitor antigen-specific T-cell responses are characterized by their high complexity and should be conducted under controlled conditions to lower multiple possible sources of assay variation. However, the lack of standard reagents makes it difficult to directly compare results generated in one lab over time and across institutions. Therefore TCR-engineered reference samples (TERS) that contain a defined number of antigen-specific T cells and continuously deliver stable results are urgently needed. We successfully established a simple and robust TERS technology that constitutes a useful tool to overcome this issue for commonly used T-cell immuno-assays. To enable users to generate large-scale TERS, on-site using the most commonly used electroporation (EP) devices, an RNA-based kit approach, providing stable TCR mRNA and an optimized manufacturing protocol were established. In preparation for the release of this immuno-control kit, we established optimal EP conditions on six devices and initiated an extended RNA stability study. Furthermore, we coordinated on-site production of TERS with 4 participants. Finally, a proficiency panel was organized to test the unsupervised production of TERS at different laboratories using the kit approach. The results obtained show the feasibility and robustness of the kit approach for versatile in-house production of cellular control samples. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Evaluation of a newly developed quantitative heart-type fatty acid binding protein assay based on fluorescence immunochromatography using specific monoclonal antibodies.

    PubMed

    Kang, Keren; Wu, Peidian; Li, Wenmei; Tang, Shixing; Wang, Jihua; Luo, Xiaochun; Xie, Mingquan

    2015-01-01

    To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R(2) = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.

  7. Improved multiple displacement amplification (iMDA) and ultraclean reagents.

    PubMed

    Motley, S Timothy; Picuri, John M; Crowder, Chris D; Minich, Jeremiah J; Hofstadler, Steven A; Eshoo, Mark W

    2014-06-06

    Next-generation sequencing sample preparation requires nanogram to microgram quantities of DNA; however, many relevant samples are comprised of only a few cells. Genomic analysis of these samples requires a whole genome amplification method that is unbiased and free of exogenous DNA contamination. To address these challenges we have developed protocols for the production of DNA-free consumables including reagents and have improved upon multiple displacement amplification (iMDA). A specialized ethylene oxide treatment was developed that renders free DNA and DNA present within Gram positive bacterial cells undetectable by qPCR. To reduce DNA contamination in amplification reagents, a combination of ion exchange chromatography, filtration, and lot testing protocols were developed. Our multiple displacement amplification protocol employs a second strand-displacing DNA polymerase, improved buffers, improved reaction conditions and DNA free reagents. The iMDA protocol, when used in combination with DNA-free laboratory consumables and reagents, significantly improved efficiency and accuracy of amplification and sequencing of specimens with moderate to low levels of DNA. The sensitivity and specificity of sequencing of amplified DNA prepared using iMDA was compared to that of DNA obtained with two commercial whole genome amplification kits using 10 fg (~1-2 bacterial cells worth) of bacterial genomic DNA as a template. Analysis showed >99% of the iMDA reads mapped to the template organism whereas only 0.02% of the reads from the commercial kits mapped to the template. To assess the ability of iMDA to achieve balanced genomic coverage, a non-stochastic amount of bacterial genomic DNA (1 pg) was amplified and sequenced, and data obtained were compared to sequencing data obtained directly from genomic DNA. The iMDA DNA and genomic DNA sequencing had comparable coverage 99.98% of the reference genome at ≥1X coverage and 99.9% at ≥5X coverage while maintaining both balance and representation of the genome. The iMDA protocol in combination with DNA-free laboratory consumables, significantly improved the ability to sequence specimens with low levels of DNA. iMDA has broad utility in metagenomics, diagnostics, ancient DNA analysis, pre-implantation embryo screening, single-cell genomics, whole genome sequencing of unculturable organisms, and forensic applications for both human and microbial targets.

  8. Evaluating Fumonisin Gene Expression in Fusarium verticillioides.

    PubMed

    Scala, Valeria; Visentin, Ivan; Cardinale, Francesca

    2017-01-01

    Transcript levels of key genes in a biosynthetic pathway are often taken as a proxy for metabolite production. This is the case of FUM1, encoding the first dedicated enzyme in the metabolic pathway leading to the production of the mycotoxins Fumonisins by fungal species belonging to the genus Fusarium. FUM1 expression can be quantified by different methods; here, we detail a protocol based on quantitative reverse transcriptase polymerase chain reaction (RT-qPCR), by which relative or absolute transcript abundance can be estimated in Fusaria grown in vitro or in planta. As very seldom commercial kits for RNA extraction and cDNA synthesis are optimized for fungal samples, we developed a protocol tailored for these organisms, which stands alone but can be also easily integrated with specific reagents and kits commercially available.

  9. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Comparative evaluation of different extraction and quantification methods for forensic RNA analysis.

    PubMed

    Grabmüller, Melanie; Madea, Burkhard; Courts, Cornelius

    2015-05-01

    Since about 2005, there is increasing interest in forensic RNA analysis whose versatility may very favorably complement traditional DNA profiling in forensic casework. There is, however, no method available specifically dedicated for extraction of RNA from forensically relevant sample material. In this study we compared five commercially available and commonly used RNA extraction kits and methods (mirVana™ miRNA Isolation Kit Ambion; Trizol® Reagent, Invitrogen; NucleoSpin® miRNA Kit Macherey-Nagel; AllPrep DNA/RNA Mini Kit and RNeasy® Mini Kit both Qiagen) to assess their relative effectiveness of yielding RNA of good quality and their compatibility with co-extraction of DNA amenable to STR profiling. We set up samples of small amounts of dried blood, liquid saliva, semen and buccal mucosa that were aged for different time intervals for co-extraction of RNA and DNA. RNA quality was assessed by determination of 'RNA integrity number' (RIN) and quantitative PCR based expression analysis. DNA quality was assessed via monitoring STR typing success rates. By comparison, the different methods exhibited considerable differences between RNA and DNA yields, RNA quality values and expression levels, and STR profiling success, with the AllPrep DNA/RNA Mini Kit and the NucleoSpin® miRNA Kit excelling at DNA co-extraction and RNA results, respectively. Overall, there was no 'best' method to satisfy all demands of comprehensible co-analysis of RNA and DNA and it appears that each method has specific merits and flaws. We recommend to cautiously choose from available methods and align its characteristics with the needs of the experimental setting at hand. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Comparison of commercial exosome isolation kits for circulating exosomal microRNA profiling.

    PubMed

    Ding, Meng; Wang, Cheng; Lu, Xiaolan; Zhang, Cuiping; Zhou, Zhen; Chen, Xi; Zhang, Chen-Yu; Zen, Ke; Zhang, Chunni

    2018-06-01

    Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. Here, we analyzed the advantages and weaknesses of four commonly used commercial kits for exosomal miRNA profiling and their application to the sample of serum and/or plasma, respectively. NanoSight and Western blotting were conducted to evaluate the efficiency and purity of the isolated exosomes. In our conditions, the size distribution of the isolated particles was appropriate (40-150 nm), and ExoQuick™ Exosome Precipitation Solution (EXQ) generated a relatively high yield of exosomes. Nevertheless, albumin impurity was ubiquitous for all the four kits, and Total Exosome Isolation for serum or plasma (TEI) yielded a relatively pure isolation. We further performed Illumina sequencing combined with RT-qPCR to determine the ability of these kits for miRNA profiling. There was significant correlation of the exosomal miRNA profile and specific miRNAs between kits, but with differences depending on methods. exoRNeasy Serum/Plasma Midi Kit (EXR) and EXQ performed better in the specific exosomal miRNAs recovery. Intraassay CVs for specific miRNA measurement were 0.88-3.82, 1.19-3.77, 0-2.70, and 1.23-9.11% for EXR, TEI, EXQ, and RIBO™ Exosome Isolation Reagent (REI), respectively. In each kit, serum yielded a higher abundance of exosomes and exosomal miRNAs than plasma, yet with more albumin impurity. In conclusion, our data provide some valuable guidance for the methodology of disease biomarker identification of circulation exosomal miRNAs. Graphical abstract Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. In this study, we compared four commonly used commercially available kits for exosomal miRNAsextraction and analyzed the advantages and weaknesses of each kit and their application to the sample ofserum and/or plasma.

  12. Field evaluation of Abbott Real Time HIV-1 Qualitative test for early infant diagnosis using dried blood spots samples in comparison to Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Qual Test in Kenya

    PubMed Central

    Chang, Joy; Omuomo, Kenneth; Anyango, Emily; Kingwara, Leonard; Basiye, Frank; Morwabe, Alex; Shanmugam, Vedapuri; Nguyen, Shon; Sabatier, Jennifer; Zeh, Clement; Ellenberger, Dennis

    2016-01-01

    Timely diagnosis and treatment of infants infected with HIV are critical for reducing infant mortality. High-throughput automated diagnostic tests like Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Qual Test (Roche CAPCTM Qual) and the Abbott Real Time HIV-1 Qualitative (Abbott Qualitative) can be used to rapidly expand early infant diagnosis testing services. In this study, the performance characteristics of the Abbott Qualitative were evaluated using two hundred dried blood spots (DBS) samples (100 HIV-1 positive and 100 HIV-1 negative) collected from infants attending the antenatal facilities in Kisumu, Kenya. The Abbott Qualitative results were compared to the diagnostic testing completed using the Roche CAPCTM Qual in Kenya. The sensitivity and specificity of the Abbott Qualitative were 99.0% (95% CI: 95.0–100.0) and 100.0% (95% CI: 96.0–100.0), respectively, and the overall reproducibility was 98.0% (95% CI: 86.0–100.0). The limits of detection for the Abbott Qualitative and Roche CAPCTM Qual were 56.5 and 6.9 copies/mL at 95% CIs (p = 0.005), respectively. The study findings demonstrate that the Abbott Qualitative test is a practical option for timely diagnosis of HIV in infants. PMID:24726703

  13. Field evaluation of Abbott Real Time HIV-1 Qualitative test for early infant diagnosis using dried blood spots samples in comparison to Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Qual test in Kenya.

    PubMed

    Chang, Joy; Omuomo, Kenneth; Anyango, Emily; Kingwara, Leonard; Basiye, Frank; Morwabe, Alex; Shanmugam, Vedapuri; Nguyen, Shon; Sabatier, Jennifer; Zeh, Clement; Ellenberger, Dennis

    2014-08-01

    Timely diagnosis and treatment of infants infected with HIV are critical for reducing infant mortality. High-throughput automated diagnostic tests like Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Qual Test (Roche CAPCTM Qual) and the Abbott Real Time HIV-1 Qualitative (Abbott Qualitative) can be used to rapidly expand early infant diagnosis testing services. In this study, the performance characteristics of the Abbott Qualitative were evaluated using two hundred dried blood spots (DBS) samples (100 HIV-1 positive and 100 HIV-1 negative) collected from infants attending the antenatal facilities in Kisumu, Kenya. The Abbott Qualitative results were compared to the diagnostic testing completed using the Roche CAPCTM Qual in Kenya. The sensitivity and specificity of the Abbott Qualitative were 99.0% (95% CI: 95.0-100.0) and 100.0% (95% CI: 96.0-100.0), respectively, and the overall reproducibility was 98.0% (95% CI: 86.0-100.0). The limits of detection for the Abbott Qualitative and Roche CAPCTM Qual were 56.5 and 6.9copies/mL at 95% CIs (p=0.005), respectively. The study findings demonstrate that the Abbott Qualitative test is a practical option for timely diagnosis of HIV in infants. Published by Elsevier B.V.

  14. Evaluation of the Abbott realtime HCV genotype II RUO (GT II) assay with reference to 5'UTR, core and NS5B sequencing.

    PubMed

    Mallory, Melanie A; Lucic, Danijela X; Sears, Mitchell T; Cloherty, Gavin A; Hillyard, David R

    2014-05-01

    HCV genotyping is a critical tool for guiding initiation of therapy and selecting the most appropriate treatment regimen. To evaluate the concordance between the Abbott GT II assay and genotyping by sequencing subregions of the HCV 5'UTR, core and NS5B. The Abbott assay was used to genotype 127 routine patient specimens and 35 patient specimens with unusual subtypes and mixed infection. Abbott results were compared to genotyping by 5'UTR, core and NS5B sequencing. Sequences were genotyped using the NCBI non-redundant database and the online genotyping tool COMET. Among routine specimens, core/NS5B sequencing identified 93 genotype 1s, 13 genotype 2s, 15 genotype 3s, three genotype 4s, two genotype 6s and one recombinant specimen. Genotype calls by 5'UTR, core, NS5B sequencing and the Abbott assay were 97.6% concordant. Core/NS5B sequencing identified two discrepant samples as genotype 6 (subtypes 6l and 6u) while Abbott and 5'UTR sequencing identified these samples as genotype 1 with no subtype. The Abbott assay subtyped 91.4% of genotype 1 specimens. Among the 35 rare specimens, the Abbott assay inaccurately genotyped 3k, 6e, 6o, 6q and one genotype 4 variant; gave indeterminate results for 3g, 3h, 4r, 6m, 6n, and 6q specimens; and agreed with core/NS5B sequencing for mixed specimens. The Abbott assay is an automated HCV genotyping method with improved accuracy over 5'UTR sequencing. Samples identified by the Abbott assay as genotype 1 with no subtype may be rare subtypes of other genotypes and thus require confirmation by another method. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Comparison of Abbott RealTime High-Risk HPV and Hybrid Capture 2 Assays for Detection of HPV Infection.

    PubMed

    Ko, Kiwoong; Yu, Shinae; Lee, Eun Hee; Park, Hyosoon; Woo, Hee-Yeon; Kwon, Min-Jung

    2016-09-01

    Various assays for detecting high-risk human papillomavirus (HR HPV) have been introduced recently, including the Abbott RealTime High-Risk HPV assay. We sought to compare the performance of Abbott PCR to Hybrid Capture 2 for the detection of HR HPV. A total of 941 cervical swab specimens were obtained. We submitted all specimens for HR HPV detection with HC2 and Abbott PCR, and then additionally analyzed discordant and concordant positive results using restriction fragment mass polymorphism (RFMP) genotyping analysis. HC2 detected one of 13 HR HPV types in 12.3% (116/941) of cases, while Abbott PCR detected one of 14 detectable HR HPV types in 12.9% (121/941) of cases. The overall agreement rate was 97.3% with a kappa coefficient of 0.879. Discordant results between these two assays were observed in 25 cases. HC2 showed a sensitivity of 90.0% and specificity of 95.9%, while Abbott PCR showed a sensitivity of 98.0% and specificity of 96.8% when using RFMP results as the gold standard. For HPV 16/18 detection, Abbott PCR showed 95.8%/88.9% sensitivity and 99.2%/99.8% specificity, respectively. The overall coinfection rate between HPV 16, 18 and non-16/18 was 9.9% (12/121) in Abbott PCR analysis. Considering its high agreement rate with HC2, higher sensitivity/specificity compared to HC2, and ability to differentiate HPV 16/18 from other HPV types, Abbott PCR could be a reliable laboratory testing method for the screening of HPV infections. © 2016 by the Association of Clinical Scientists, Inc.

  16. A multicenter nationwide reference intervals study for common biochemical analytes in Turkey using Abbott analyzers.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Aslan, Diler; Aybek, Hulya; Ari, Zeki; Taneli, Fatma; Coker, Canan; Akan, Pinar; Sisman, Ali Riza; Bahceci, Onur; Sezgin, Nurzen; Demir, Meltem; Yucel, Gultekin; Akbas, Halide; Ozdem, Sebahat; Polat, Gurbuz; Erbagci, Ayse Binnur; Orkmez, Mustafa; Mete, Nuriye; Evliyaoglu, Osman; Kiyici, Aysel; Vatansev, Husamettin; Ozturk, Bahadir; Yucel, Dogan; Kayaalp, Damla; Dogan, Kubra; Pinar, Asli; Gurbilek, Mehmet; Cetinkaya, Cigdem Damla; Akin, Okhan; Serdar, Muhittin; Kurt, Ismail; Erdinc, Selda; Kadicesme, Ozgur; Ilhan, Necip; Atali, Dilek Sadak; Bakan, Ebubekir; Polat, Harun; Noyan, Tevfik; Can, Murat; Bedir, Abdulkerim; Okuyucu, Ali; Deger, Orhan; Agac, Suret; Ademoglu, Evin; Kaya, Ayşem; Nogay, Turkan; Eren, Nezaket; Dirican, Melahat; Tuncer, GulOzlem; Aykus, Mehmet; Gunes, Yeliz; Ozmen, Sevda Unalli; Kawano, Reo; Tezcan, Sehavet; Demirpence, Ozlem; Degirmen, Elif

    2014-12-01

    A nationwide multicenter study was organized to establish reference intervals (RIs) in the Turkish population for 25 commonly tested biochemical analytes and to explore sources of variation in reference values, including regionality. Blood samples were collected nationwide in 28 laboratories from the seven regions (≥400 samples/region, 3066 in all). The sera were collectively analyzed in Uludag University in Bursa using Abbott reagents and analyzer. Reference materials were used for standardization of test results. After secondary exclusion using the latent abnormal values exclusion method, RIs were derived by a parametric method employing the modified Box-Cox formula and compared with the RIs by the non-parametric method. Three-level nested ANOVA was used to evaluate variations among sexes, ages and regions. Associations between test results and age, body mass index (BMI) and region were determined by multiple regression analysis (MRA). By ANOVA, differences of reference values among seven regions were significant in none of the 25 analytes. Significant sex-related and age-related differences were observed for 10 and seven analytes, respectively. MRA revealed BMI-related changes in results for uric acid, glucose, triglycerides, high-density lipoprotein (HDL)-cholesterol, alanine aminotransferase, and γ-glutamyltransferase. Their RIs were thus derived by applying stricter criteria excluding individuals with BMI >28 kg/m2. Ranges of RIs by non-parametric method were wider than those by parametric method especially for those analytes affected by BMI. With the lack of regional differences and the well-standardized status of test results, the RIs derived from this nationwide study can be used for the entire Turkish population.

  17. [Use of molecular genetic diagnostic methods in periodontology and implantology].

    PubMed

    Shcherbo, S N; Choniashvili, D Z; De, D A; Sadovskiĭ, V V; Toguzov, R T

    2009-11-01

    The authors have studied the species-specific composition of major periodontopathogenic bacteria (P. gingivalis, P. intermedia, B. forsythus, A. actinomycetemcomitans, and T. denticola), by applying the Russian reagent kit developed and made by HPF "GENETECH", and some fungi, microorganisms, and viruses among the Moscow Region inhabitants with chronic generalized periodontitis in 2006-2008. The studies have shown it possible to use molecular genetic methods for diagnosis, drug therapy monitoring, and epidemiological studies in periodontology and implantology.

  18. Determination of MIL-H-6083 Hydraulic Fluid In-Service Use Limits for Self-Propelled Artillery

    DTIC Science & Technology

    1991-09-01

    determined using the American Society for Testing and Materials (ASTM) D1744 Karl Fischer Reagent method . The specification limit is 0.05% (500 pans per...cazefully controlled. TOTAL ACID NUMBER The acid number was determined by the ASTM D664 potentiometric titration test method . Unfortunately, data were...fluid condition t results with AOAP tent date was found. The Navy Patch Kit method for particle contamination meamrement was evaluated as a possible

  19. Product development: the making of the Abbott ARCHITECT.

    PubMed

    Kisner, H J

    1997-01-01

    Many laboratorians have a limited perspective on what is involved in developing an instrument and bringing it to market. This article traces the product development process used by Abbott Diagnostics Division that resulted in Abbott being named the 1996 Concurrent Engineering Company of the Year for the design of the ARCHITECT.

  20. 78 FR 23220 - Foreign-Trade Zone 22-Chicago, Illinois, Authorization of Production Activity, Abbott...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-18

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [B-91-2012] Foreign-Trade Zone 22--Chicago, Illinois, Authorization of Production Activity, Abbott Laboratories, Inc., AbbVie, Inc. (Pharmaceutical Production), North Chicago, Illinois, Area On December 14, 2012, Abbott Laboratories, Inc., and AbbVie, Inc...

  1. Detection of Mycobacterium tuberculosis Complex in Paraffin-Embedded Tissues by the New Automated Abbott RealTime MTB Assay.

    PubMed

    Fu, Yung-Chieh; Liao, I-Chuang; Chen, Hung-Mo; Yan, Jing-Jou

    2016-07-01

    The Abbott RealTime MTB assay, launched in June 2014, has been shown to have a competitive performance in the detection of the Mycobacterium tuberculosis (MTB) complex in respiratory specimens. The present study was conducted to investigate the usefulness of the Abbott MTB Realtime assay in the detection of MTB in formalin-fixed paraffin-embedded (FFPE) tissues. A total of 96 FFPE specimens obtained from microbiologically proven MTB cases (N=60) and nontuberculous Mycobacterium cases (N=36) were analyzed. The performance of the Abbott MTB Realtime assay was compared with that of the Roche Cobas TaqMan MTB assay. The overall sensitivity and specificity of the Abbott assay were 63.3% and 97.2%, respectively, compared with 11.7% and 100% for the Cobas assay. The detection rate of the Abbott assay was much higher among 37 acid-fast-positive specimens than among 23 acid-fast-negative specimens (89.3% versus 21.7%, respectively). The detection rate of the assay was higher among 29 resection specimens than among 31 small biopsy specimens (86.2% versus 41.9%, respectively). Our results suggest that the Abbott RealTime MTB assay can be used to differentiate MTB from nontuberculous mycobacterial infections in acid-fast-positive FFPE tissues. © 2016 by the Association of Clinical Scientists, Inc.

  2. SMART Digest™ compared with pellet digestion for analysis of human immunoglobulin G1 in rat serum by liquid chromatography tandem mass spectrometry.

    PubMed

    Lanshoeft, Christian; Heudi, Olivier; Cianférani, Sarah

    2016-05-15

    The newly developed SMART Digest™ kit was applied for the sample preparation of human immunoglobulin G1 (hIgG1) in rat serum prior to qualitative and quantitative analyses by liquid chromatography tandem mass spectrometry (LC-MS/MS). The sequence coverages obtained for the light and heavy chains of hIgG1A were 50 and 76%, respectively. The calibration curve was linear from 1.00 to 1000 μg/ml for three of four generic peptides. Overall, the SMART Digest™ kit resulted in similar quantitative data (linearity, sensitivity, accuracy, and precision) compared with the pellet digestion protocol. However, the SMART Digest™ required only 2 h of sample preparation with fewer reagents. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Method of detecting genetic translocations identified with chromosomal abnormalities

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas

    2001-01-01

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  4. Chromosome-specific staining to detect genetic rearrangements

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas; Westbrook, Carol

    2013-04-09

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  5. Method of detecting genetic deletions identified with chromosomal abnormalities

    DOEpatents

    Gray, Joe W; Pinkel, Daniel; Tkachuk, Douglas

    2013-11-26

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acids probes are typically of a complexity greater tha 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particlularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar ut genetically different diseases, and for many prognostic and diagnostic applications.

  6. 75 FR 340 - Approval for Expansion of Subzone 22F, Abbott Molecular, Inc. (Pharmaceutical and Molecular...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-05

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Order No. 1654] Approval for Expansion of Subzone 22F, Abbott Molecular, Inc. (Pharmaceutical and Molecular Diagnostic Products), Chicago, IL, Area... manufacturing authority on behalf of Abbott Molecular, Inc., within FTZ 22F in Des Plaines and Elk Grove Village...

  7. Abbott Students Attending Charter Schools: Funding Disparities and Legal Implications

    ERIC Educational Resources Information Center

    Bulkley, Katrina

    2007-01-01

    Most of New Jersey's charter schools are located in the state's poorer, urban school districts, or "Abbott" districts, and exclusively serve students from those communities. A number of other schools are located outside of the Abbott districts but enroll students from these districts. Specifically, of the 50 charter schools operating in…

  8. Harmonization of the Bayer ADVIA Centaur and Abbott AxSYM automated B-type natriuretic peptide assay in patients on hemodialysis.

    PubMed

    Barak, Mira; Weinberger, Ronit; Marcusohn, Jerom; Froom, Paul

    2005-01-01

    There are two fully automated high-throughput clinical instruments for brain natriuretic peptide (BNP) assays, the Bayer ADVIA Centaur assay, and the Abbott AxSYM assay. Although both recommend a cut-off value of 100 pg/mL, we are unaware of previous studies that have compared the unadjusted results of the two methods, required for proper evaluation of patients undergoing this test on different platforms. From 43 hemodialysis patients, 80 paired samples were collected by venipuncture into plastic evacuated tubes containing EDTA. The Bayer assay yielded lower values than the Abbott assay, with linear regression of 0.53 x Abbott assay (95% confidence interval, 0.50-0.56) being forced through 0, demonstrating an r(2)-value of 0.954. Regression for the Abbott assay was 1.79 x Bayer assay (95% CI, 1.69-1.89). The cut-off values for abnormal BNP results analyzed on the Abbott system are not identical to those on the Bayer system, and this needs to be taken into account when comparing studies on the clinical utility of these systems.

  9. ABT-773 (Abbott Laboratories).

    PubMed

    Lawrence, L E

    2001-06-01

    ABT-773 is a macrolide antibacterial agent under development by Abbott Laboratories and Taisho Pharmaceutical Co Ltd for the potential treatment of bacterial infection [266579]. As of February 2001, ABT-773 had entered phase III trials in the US [398274]. Japanese phase II trials were expected to commence in June 2000 and a phase II trial is being designed for respiratory infections, with Abbott expecting filing in March 2002 [360455]. The bioavailability of ABT-773 in humans is unaffected by food [383228] and in a phase I, randomized, double-blind trial in healthy males only mild adverse effects, usually affecting the gastrointestinal system, were observed [383208]. Under an agreement, Abbott and Taisho are conducting joint research to discover new compounds; Abbott will have worldwide marketing, manufacturing and supply rights (except in Japan), and Taisho will receive royalties on Abbott's sales in consideration of granted rights. In Japan, the companies will co-market any resulting compounds [266579]. ABT-773 demonstrated good activity in vitro and in vivo against Streptococcus pneumoniae and Staphylococcus aureus [383229], [383231], and was highly potent even against macrolide-resistant [382149], [382150] and invasive [383782] S pneumoniae.

  10. Impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott RealTime HCV Genotype II assay for hepatitis C genotyping.

    PubMed

    Sridhar, Siddharth; Yip, Cyril C Y; Chan, Jasper F W; To, Kelvin K W; Cheng, Vincent C C; Yuen, Kwok-Yung

    2018-05-01

    The Abbott RealTime HCV Genotype II assay (Abbott-RT-HCV assay) is a real-time PCR based genotyping method for hepatitis C virus (HCV). This study measured the impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott-RT-HCV assay. 517 samples were genotyped using the Abbott-RT-HCV assay over a one-year period, 34 (6.6%) were identified as HCV genotype 1 without further subtype designation raising the possibility of inaccurate genotyping. These samples were subjected to confirmatory sequencing. 27 of these 34 (79%) samples were genotype 1b while five (15%) were genotype 6. One HCV isolate was an inter-genotypic 1a/4o recombinant. This is a novel natural HCV recombinant that has never been reported. Inter-genotypic recombination and probe cross-reactivity can affect the accuracy of the Abbott-RT-HCV assay, both of which have significant implications on antiviral regimen choice. Confirmatory sequencing of ambiguous results is crucial for accurate genotyping. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Comparison of the clinical performances of the AdvanSure HPV Screening Real-Time PCR, the Abbott Real-Time High-Risk HPV Test, and the Hybrid Capture High-Risk HPV DNA Test for Cervical Cancer Screening.

    PubMed

    Chung, Hae-Sun; Hahm, Chorong; Lee, Miae

    2014-09-01

    The clinical performance of three human papillomavirus (HPV) DNA commercial assays for cervical cancer screening was evaluated; the AdvanSure HPV Screening Real-Time PCR (AdvanSure PCR; LG Life Sciences) that was developed recently for the detection of both high-risk and low-risk genotypes, the Abbott RealTime High-Risk HPV Test (Abbott PCR; Abbott Molecular) and the Hybrid Capture High-Risk HPV DNA test (HC2; Qiagen). The three different HPV DNA tests were compared using cytology samples obtained from 619 women who underwent routine cervical cancer screening. The gold-standard assay was histopathological confirmation of cervical intraepithelial neoplasia of grade 2 or worse. The clinical sensitivities of the AdvanSure PCR, the Abbott PCR and the HC2 for the detection of cervical intraepithelial neoplasia of grade 2 or worse were 95.5%, 95.5% and 100%, respectively, while the clinical specificities were 61.6%, 86.4% and 83.3%, respectively. There were no significant differences in the clinical sensitivities of the Abbott PCR and the AdvanSure PCR compared to the HC2. The clinical specificities of the Abbott PCR and the AdvanSure PCR for the detection of HPV types 16/18 were 97.8% and 98.5%, respectively. For cervical cancer screening, all three tests showed relatively good clinical sensitivities, but the AdvanSure PCR had lower clinical specificity than the Abbott PCR and the HC2. The AdvanSure PCR and the Abbott PCR assays have the advantage of being automated and the ability to distinguish between HPV types 16/18 and other HPV types. The two real-time PCR assays could be useful tools in HPV testing for cervical cancer screening. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Abbott Preschool Program Longitudinal Effects Study: Fifth Grade Follow-Up

    ERIC Educational Resources Information Center

    Barnett, W. Steven; Jung, Kwanghee; Youn, Min-Jong; Frede, Ellen C.

    2013-01-01

    New Jersey's Abbott Preschool program is of broad national and international interest because the Abbott program provides a model for building a high-quality system of universal pre-K through public-private partnerships that transform the existing system. The program offers high-quality pre-K to all children in 31 New Jersey communities with high…

  13. The Abbott Preschool Program: Fifth Year Report on Enrollment and Budget

    ERIC Educational Resources Information Center

    Applewhite, Erain; Hirsch, Lesley

    2003-01-01

    The New Jersey Supreme Court's 1998 ruling in Abbott v. Burke represents the first judicial directive in the nation that public education must include a high-quality, well-planned preschool program starting at age three. This decision applies to 30 urban school districts, known as the Abbott districts, that serve approximately 25 percent of the…

  14. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to themore » technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel Dog Soil Test Kit.« less

  15. Cethromycin: A-195773, A-195773-0, A-1957730, Abbott-195773, ABT 773.

    PubMed

    2007-01-01

    Cethromycin [ABT 773, A-195773, Abbott-195773, A-1957730, A-195773-0] is a once-daily ketolide antibiotic that originated from Abbott Laboratories' research into next-generation compounds to the macrolide antibacterial, clarithromycin. The aim of the research programme was to maintain the positive attributes of clarithromycin and to add the property of efficacy against macrolide-resistant organisms. Cethromycin acts by binding to the 23S molecule of the 50S ribosomal subunit. Advanced Life Sciences is conducting multinational, pivotal phase III trials of cethromycin for the treatment of mild-to-moderate community-acquired pneumonia, phase II/III trials for treatment of acute bacterial sinusitis, as well as preclinical trials for the treatment of anthrax. Advanced Life Sciences plans to advance discussions with prospective commercialisation partners for cethromycin during 2006. Abbott Laboratories and Taisho Pharmaceutical entered a collaboration to develop and commercialise new macrolide antibacterials in October 1997. Each company brought its existing macrolides into the collaboration and both companies were to jointly develop novel new macrolides. Abbott was to have exclusive marketing, manfacturing and supply rights worldwide (except in Japan) to any compounds resulting from this collaboration. Taisho was to receive royalties on Abbott's sales in consideration of granted rights. In Japan, the two companies were to co-market any resulting macrolide antibacterials. This agreement extended to the development of cethromycin; however, the agreement was suspended in April 2004 and appears to have been terminated. Abbott exclusively licensed cethromycin to Advanced Life Sciences worldwide excluding Japan in December 2004. Advanced Life Sciences initiated commercial manufacturing agreements for cethromycin with DSM and Cardinal Health in May 2006. In March 2006, Advanced Life Sciences completed private placement of $US36 million from which the net proceeds will be used to advance development of cethromycin. The company plans to submit an NDA for cethromycin in 2007. In Japan, phase II trials were being conducted with Abbott's partner, Taisho Pharmaceutical. Although development in the US had been put on hold, Abbott was to continue to support product development in Japan by Taisho. However, in April 2004, Taisho and Abbott Japan decided to suspend co-development activities for cethromycin. A patent has been granted for cethromycin (US patent number 5 866 549) that expires in September 2016.

  16. Field determination of PCB in transformer oil. Volume 2. Clor-N-Oil PCB screening test. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, D.J.; Rouse, T.O.; Lynn, T.

    1984-10-01

    The requirements for handling and disposing of transformer minerals oils containing more than 50 ppM PCB are, by federal regulation, different from those for oils containing lower concentrations. A rapid and simple test to distinguish between samples containing more than or less than this concentration would simplify proper control of transformer oils. This report describes the development of a small disposable test kit that can be used on-site to screen the chlorine content of transformer oils. The kit consists of two soft plastic tubes in which thin walled glass ampules containing premeasured amounts of reagents are broken. The reaction sequencemore » in the kits converts the chlorine in PCB to chloride ion. The color of the liquid in the kit after the last step is blue to purple if the chloride content due to the initial chlorine concentration of the oil is less than 20 ppM. If the chlorine content of the oil is below 20 ppM, the PCB content must be below 50 ppM. The liquid is colorless if the chlorine content is greater than 20 ppM. In this latter case, it is necessary to determine by gas chromatography whether the PCB content is actually greater than 50 ppM or if there is some other source of chlorine in the oil.« less

  17. Inventions leading to the development of the diagnostic test kit industry--from the modern pregnancy test to the sandwich assays.

    PubMed

    Wide, Leif

    2005-01-01

    The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some crucial steps of the innovation processes.

  18. A simple microplate-based method for the determination of α-amylase activity using the glucose assay kit (GOD method).

    PubMed

    Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini

    2016-11-15

    For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Methods of staining target chromosomal DNA employing high complexity nucleic acid probes

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Kallioniemi, Ol'li-Pekka; Kallioniemi, Anne; Sakamoto, Masaru

    2006-10-03

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML), retinoblastoma, ovarian and uterine cancers, and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  20. Chromosome-specific staining to detect genetic rearrangements associated with chromosome 3 and/or chromosome 17

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Kallioniemi, Olli-Pekka; Kallioniemi, Anne; Sakamoto, Masaru

    2002-01-01

    Methods and compositions for staining based upon nucleic acid sequence that employ nudeic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML), retinoblastoma, ovarian and uterine cancers, and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  1. Chromosome-specific staining to detect genetic rearrangements associated with chromosome 3 and/or chromosome 17

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Kallioniemi, Olli-Pekka; Kallioniemi, Anne; Sakamoto, Masaru

    2008-09-09

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML), retinoblastoma, ovarian and uterine cancers, and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  2. Chromosome-specific staining to detect genetic rearrangements associated with chromosome 3 and/or chromosome 17

    DOEpatents

    Gray, Joe W [San Francisco, CA; Pinkel, Daniel [Lafayette, CA; Kallioniemi, Olli-Pekka [Turku, FI; Kallioniemi, Anne [Tampere, FI; Sakamoto, Masaru [Tokyo, JP

    2009-10-06

    Methods and compositions for staining based upon nucleic acid sequence that employ .[.nudeic.]. .Iadd.nucleic .Iaddend.acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML), retinoblastoma, ovarian and uterine cancers, and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  3. Chromosome-Specific Staining To Detect Genetic Rearrangements Associated With Chromosome 3 And/Or Chromosone 17

    DOEpatents

    Gray; Joe W.; Pinkel; Daniel; Kallioniemi; Olli-Pekka; Kallioniemi; Anne; Sakamoto; Masaru

    2002-02-05

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML), retinoblastoma, ovarian and uterine cancers, and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  4. Evaluation of the Abbott RealTime HCV assay for quantitative detection of hepatitis C virus RNA.

    PubMed

    Michelin, Birgit D A; Muller, Zsofia; Stelzl, Evelyn; Marth, Egon; Kessler, Harald H

    2007-02-01

    The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.

  5. Performance evaluation of a chemiluminescence microparticle immunoassay for CK-MB.

    PubMed

    Lin, Zhi-Yuan; Fang, Yi-Zhen; Jin, Hong-Wei; Lin, Hua-Yue; Dai, Zhang; Luo, Qing; Li, Hong-Wei; Lin, Yan-Ling; Huang, Shui-Zhen; Gao, Lei; Xu, Fei-Hai; Zhang, Zhong-Ying

    2018-03-31

    To verify and evaluate the performance characteristics of a creatine kinase phosphokinase isoenzymes MB (CK-MB) assay kit, which produced by Xiamen Innodx Biotech Co. Ltd. Evaluation was carried out according to "Guidelines for principle of analysis performance evaluation of in vitro diagnostic reagent." The performance parameters included detection limit, linearity range, reportable range, recovery test, precision verification, interference test, cross-reactivity, matrix effect, and method comparison. The detection limit was 0.1 ng/mL. The assay had clinical linearity over range of 0.1 ng/mL-500 ng/mL. Reportable range was from 0.1 ng/mL to 1000 ng/mL. The average percent of recovery was 99.66%. The coefficient of variation (CV) for within-run and between-run of low CK-MB sample was 5.55% and 6.16%, respectively. As for high-level sample, it was 7.88% and 7.80%. In medical decision level, the relative deviation (Bias) of all interference tests was lower than 15%. When the sample had mild-hemolysis; hemoglobin ≤15 g/L; triglyceride ≤17 mmol/L; bilirubin ≤427.5 μmol/L; rheumatoid factor ≤206U/mL, there was no significant interference to be found. Moreover, assay kit had no cross-reaction with CK-MM and CK-BB. At last, total diagnostic accuracy of kit was 93.24%, when compared with refer kit. Overall the results of the verification study indicated the performance of kit is met the requirements of the clinical test. © 2018 Wiley Periodicals, Inc.

  6. Establishment and Evaluation of a One-Step Microplate Chemiluminescence Immunoassay to Detect IgG Antibody Against Treponema Pallidum.

    PubMed

    Liu, Lijuan; Xie, Yuling; Dai, Zhenxian; Zhuo, Chuanshang; Wu, Yushui

    2015-11-01

    The serological detection of specific antibodies against Treponema pallidum is of particular importance in the diagnosis of syphilis. The chemiluminescence immunoassay (CLIA) has been widely used for clinical diagnosis because they remit no radical waste products, cause no enzyme precipitation, and exhibit an excellent sensitivity. A one-step CLIA was established to detect T. pallidum IgG antibody based on microplate coated with a mixture of recombinant T. pallidum antigens TpN15, TpN17, and TpN47. The Chinese national reference substances standard panel for T. pallidum diagnosis was applied to test the accuracy, stability, interference, and cross-reactivity of the established CLIA. The validation of efficacy for clinical application was performed by comparing the established method with the marketed T. pallidum particle agglutination (TPPA) kit and the Abbott ARCHITEC Auto System. The established method met the requirement of the Chinese national reference substances standard for T. pallidum diagnosis. When compared with TPPA (n = 1,052), the specificity, sensitivity, and overall concordance were 99.7%, 99.0%, and 98.8% respectively, showing a great agreement with a kappa value of 0.81. When compared with the Abbott ARCHITEC Auto System (n = 352), the results showed that the specificity, sensitivity, and overall concordance were 98.6.0%, 96.6% and 98.6% respectively, and a high-degree agreement was observed (kappa value = 0.95). The established rapid, specific, sensitive, and stable microplate CLIA method to detect IgG antibody against T pallidum will provide an efficient alternative to the treponemal tests and wide application in clinical laboratory. © 2014 Wiley Periodicals, Inc.

  7. Detection of mycobacterium tuberculosis in paraffin-embedded pleural biopsy specimens by commercial ribosomal RNA and DNA amplification kits.

    PubMed

    Ruiz-Manzano, J; Manterola, J M; Gamboa, F; Calatrava, A; Monsó, E; Martínez, C; Ausina, V

    2000-09-01

    To evaluate the utility of two gene amplification systems in historical paraffin-embedded pleural biopsy (PEB) tissues from patients with pleural tuberculosis, and to compare the results to those obtained with conventional histologic and microbiological methods. A retrospective study. Seventy-four formalin-fixed PEB tissues collected and stored over 12 years (1984 through 1995) were retrieved. Gene amplifications were performed in 57 tissues from patients with diagnoses of pleural tuberculosis and in 17 from patients with carcinoma as controls, using the first version of the Amplified Mycobacterium tuberculosis Direct Test (AMTDT; Gen-Probe; San Diego, CA) and the LCx Mycobacterium tuberculosis Assay (LCxMTB; Abbott Laboratories; Abbott Park, IL). The sensitivities of the AMTDT and LCxMTB were 52.6% and 63.2%, respectively (p = not statistically significant). The specificity of both tests was 100%. Twenty tissue samples (35.1%) were positive by both systems, and 10 tissues (17.5%) were positive only by the AMTDT, while 16 tissues (28.1%) were positive only by the LCxMTB. Both tests gave negative results for 11 specimens (19.3%). When both tests were used, a positive diagnosis was achieved in 80.7% of the samples. Diagnosis of 73.7% of patient conditions had previously been made by smear examination of pleural biopsy and sputum, pleural liquid, or biopsy culture. The overall diagnostic yield with both culture and amplification techniques was 96.5% (55 of 57 patients) for pleural tuberculosis, with amplification techniques adding 22.8% of the diagnoses. Amplification techniques are useful in archival PEB tissues, providing additional diagnoses beyond culturing, although the sensitivity should be improved, possibly by standardizing protocols.

  8. The effect of extremely high glucose concentrations on 21 routine chemistry and thyroid Abbott assays: interference study.

    PubMed

    Çuhadar, Serap; Köseoğlu, Mehmet; Çinpolat, Yasemin; Buğdaycı, Güler; Usta, Murat; Semerci, Tuna

    2016-01-01

    Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L. Baseline (group I) serum pool with glucose concentration of 5.55 (5.44-5.61) mmol/L was prepared from patient sera. Spiking with 20% dextrose solution, sample groups were obtained with glucose concentrations: 17.09, 34.52, and 50.95 mmol/L (group II, III, IV, respectively). Total of 21 biochemistry analytes and thyroid tests were studied on Abbott c8000 and i2000sr with commercial reagents. Bias from baseline value was checked statistically and clinically. Creatinine increased significantly by 8.74%, 31.66%, 55.31% at groups II, III, IV, respectively with P values of < 0.001. At the median glucose concentration of 50.95 mmol/L, calcium, albumin, chloride and FT4 biased significantly clinically (-0.85%, 1.63%, 0.65%, 7.4% with P values 0.138, 0.214, 0.004, < 0.001, respectively). Remaining assays were free of interference. Among the numerous biochemical parameters studied, only a few parameters are affected by dramatically increased glucose concentration. The creatinine measurements obtained in human sera with the Jaffe alkaline method at high glucose concentrations should be interpreted with caution. Other tests that were affected with extremely high glucose concentrations were calcium, albumin, chloride and FT4, hence results should be taken into consideration in patients with poor diabetic control.

  9. Standardization and performance evaluation of "modified" and "ultrasensitive" versions of the Abbott RealTime HIV-1 assay, adapted to quantify minimal residual viremia.

    PubMed

    Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2011-09-01

    Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected <40 cp/mL" in the standard assay. The "modified" and "ultrasensitive" assays are precise and accurate, and easily adoptable in routine diagnostic laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Colorimetric Solid Phase Extraction (CSPE): Using Color to Monitor Spacecraft Water Quality

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2010-01-01

    In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS). The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was launched as a Station Development Test Objective (SDTO) experiment to evaluate the suitability of CSPE technology for routine use monitoring water quality on the ISS. CSPE is a sorption-spectrophotometric technique that combines colorimetric reagents, solid-phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water samples. In CSPE, a known volume of sample is metered through a membrane disk that has been impregnated with an analyte-specific colorimetric reagent and any additives required to optimize the formation of the analyte-reagent complex. As the sample flows through the membrane disk, the target analyte is selectively extracted, concentrated, and complexed. Formation of the analyte-reagent complex causes a detectable change in the color of the membrane disk that is proportional to the amount of analyte present in the sample. The analyte is then quantified by measuring the color of the membrane disk surface using a hand-held diffuse reflectance spectrophotometer (DRS). The CWQMK provides the capability to measure the ionic silver (Ag +) and molecular iodine (I2) in water samples on-orbit. These analytes were selected for the evaluation of CSPE technology because they are the biocides used in the potable water storage and distribution systems on the ISS. Biocides are added to the potable water systems on spacecraft to inhibit microbial growth. On the United States (US) segment of the ISS molecular iodine serves as the biocide, while the Russian space agency utilizes silver as a biocide in their systems. In both cases, the biocides must be maintained at a level sufficient to control bacterial growth, but low enough to avoid any negative effects on crew health. For example, the presence of high levels of iodine in water can cause taste and odor issues that result in decreased water consumption by the crew. There are also concerns about potential impacts on thyroid function following exposure to high levels of iodine. With silver, there is a risk of developing argyria, an irreversible blue-gray discoloration of the skin, associated with long term consumption of water containing high concentrations of silver. The need to ensure that safe, effective levels of biocide are maintained in the potable water systems on the ISS provides a perfect platform for evaluating the suitability of CSPE technology for in-flight water quality monitoring. This paper provides an overview of CSPE technology and details on the silver and iodine methods used in the CWQMK. It also reports results obtained during in-flight analyses performed with the CWQMK and briefly discusses other potential applications for CSPE technology in both the spacecraft and terrestrial environments.

  11. Partnering for Preschool: A Study of Center Directors in New Jersey's Mixed-Delivery Abbott Program. Research Report

    ERIC Educational Resources Information Center

    Whitebook, Marcy; Ryan, Sharon; Kipnis, Fran; Sakai, Laura

    2008-01-01

    In a series of New Jersey Supreme Court decisions known as Abbott v. Burke, the 28 (now 31) urban school districts serving the state's poorest students were ordered to create systems of high-quality preschool for all three- and four-year-old children, beginning in the 1999-2000 school year. The Abbott Preschool Program now serves approximately…

  12. Fulfilling the Promise of Abbott: The Lighthouse Assessment Process--Improving Programs through Measured Outcomes. Policy Progress, Spring 2004

    ERIC Educational Resources Information Center

    Association for Children of New Jersey, 2004

    2004-01-01

    In an attempt to better prepare young children for the challenges of kindergarten and first grade, the Supreme Court of New Jersey, in its 1998 landmark decision of "Abbott v. Burke" (Abbott V), required the State's poorest school districts to implement high quality, intensive preschool for all 3-and 4-year old children. To take…

  13. An OPTIMIZE study retrospective analysis for management of telaprevir-treated hepatitis C virus (HCV)-infected patients by use of the Abbott RealTime HCV RNA assay.

    PubMed

    Sarrazin, Christoph; Dierynck, Inge; Cloherty, Gavin; Ghys, Anne; Janssen, Katrien; Luo, Donghan; Witek, James; Buti, Maria; Picchio, Gaston; De Meyer, Sandra

    2015-04-01

    Protease inhibitor (PI)-based response-guided triple therapies for hepatitis C virus (HCV) infection are still widely used. Noncirrhotic treatment-naive and prior relapser patients receiving telaprevir-based treatment are eligible for shorter, 24-week total therapy if HCV RNA is undetectable at both weeks 4 and 12. In this study, the concordance in HCV RNA assessments between the Roche High Pure System/Cobas TaqMan and Abbott RealTime HCV RNA assays and the impacts of different HCV RNA cutoffs on treatment outcome were evaluated. A total of 2,629 samples from 663 HCV genotype 1 patients receiving telaprevir/pegylated interferon/ribavirin in OPTIMIZE were analyzed using the High Pure System and reanalyzed using Abbott RealTime (limits of detection, 15.1 IU/ml versus 8.3 IU/ml; limits of quantification, 25 IU/ml versus 12 IU/ml, respectively). Overall, good concordance was observed between the assays. Using undetectable HCV RNA at week 4, 34% of the patients would be eligible for shorter treatment duration with Abbott RealTime versus 72% with the High Pure System. However, using <12 IU/ml for Abbott RealTime, a similar proportion (74%) would be eligible. Of the patients receiving 24-week total therapy, 87% achieved a sustained virologic response with undetectable HCV RNA by the High Pure System or <12 IU/ml by Abbott RealTime; however, 92% of the patients with undetectable HCV RNA by Abbott RealTime achieved a sustained virologic response. Using undetectable HCV RNA as the cutoff, the more sensitive Abbott RealTime assay would identify fewer patients eligible for shorter treatment than the High Pure System. Our data confirm the <12-IU/ml cutoff, as previously established in other studies of the Abbott RealTime assay, to determine eligibility for shortened PI-based HCV treatment. (The study was registered with ClinicalTrials.gov under registration no. NCT01241760.). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  14. Comparison of Abbott and Da-an real-time PCR for quantitating serum HBV DNA.

    PubMed

    Qiu, Ning; Li, Rui; Yu, Jian-Guo; Yang, Wen; Zhang, Wei; An, Yong; Li, Tong; Liu, Xue-En; Zhuang, Hui

    2014-09-07

    To compare the performance of the Da-an real-time hepatitis B virus (HBV) DNA assay and Abbott RealTime HBV assay. HBV DNA standards as well as a total of 180 clinical serum samples from patients with chronic hepatitis B were measured using the Abbott and Da-an real-time polymerase chain reaction (PCR) assays. Correlation and Bland-Altman plot analysis was used to compare the performance of the Abbott and Da-an assays. The HBV DNA levels were logarithmically transformed for analysis. All statistical analyses were performed using SPSS for Windows version 18.0. The correlation between the two assays was analyzed by Pearson's correlation and linear regression. The Bland-Altman plots were used for the analysis of agreement between the two assays. A P value of < 0.05 was considered statistically significant. The HBV DNA values measured by the Abbott or Da-an assay were significantly correlated with the expected values of HBV DNA standards (r = 0.999, for Abbott; r = 0.987, for Da-an, P < 0.001). A Bland-Altman plot showed good agreement between these two assays in detecting HBV DNA standards. Among the 180 clinical serum samples, 126 were quantifiable by both assays. Fifty-two samples were detectable by the Abbott assay but below the detection limit of the Da-an assay. Moreover, HBV DNA levels measured by the Abbott assay were significantly higher than those of the Da-an assay (6.23 ± 1.76 log IU/mL vs 5.46 ± 1.55 log IU/mL, P < 0.001). A positive correlation was observed between HBV DNA concentrations determined by the two assays in 126 paired samples (r = 0.648, P < 0.001). One hundred and fifteen of 126 (91.3%) specimens tested with both assays were within mean difference ± 1.96 SD of HBV DNA levels. The Da-an assay presented lower sensitivity and a narrower linear range as compared to the Abbott assay, suggesting the need to be improved.

  15. Determination of aflatoxin B1 in food and feedstuffs in Cuba (1990 through 1996) using an immunoenzymatic reagent kit (Aflacen).

    PubMed

    Escobar, Arturo; Regueiro, Olga Sanchez

    2002-01-01

    The presence of aflatoxin B1 was analyzed in imported food and feedstuffs of national production in the period of 1990 through 1996, destined to animal and human consumption using an immunoenzymatic reagent kit (Aflacen, Ckure, la Habana, Cuba) with a detection limit of 0.3 microg/kg. It was found that the 17.04% of a total of 4,594 analyzed samples presented aflatoxin B1, and the biggest percentages were in sorghum and peanut with an 83.3 and 40.4%, respectively. The corn, oat, wheat, and soy are fundamental raw ingredients in the elaboration of concentrates. Percentages of contamination with aflatoxin B1 of 23.3, 10.7, 25, and 4.6 were found in corn, oat, wheat, and soy, respectively. Other analyzed foods like rice, beans, and peas presented percentages of contamination with aflatoxin B1 inferior to 5% of the analyzed samples. It was found that more than 455 samples surpassed the value of 10 microg/kg. Corn and peanut products present a high demand in population showing levels of contamination superior to 50 microg/kg. The 11.3% of the samples contaminated with aflatoxin B1 have values between 1 and 20 microg/kg, where peanut and concentrates show the highest percentages (21.9 and 18.7), respectively. These results show levels of aflatoxin B1 in the population that constitute a great risk for human and animal health.

  16. Immobilization of microalgae cells in alginate facilitates isolation of DNA and RNA.

    PubMed

    Lopez, Blanca R; Hernandez, Juan-Pablo; Bashan, Yoav; de-Bashan, Luz E

    2017-04-01

    Isolation of nucleic acids from Chlorella is difficult, given the chemically complex nature of their cell walls and variable production of metabolites. Immobilization of microalgae in polymers adds additional difficulty. Here, we modified, amended, and standardized methods for isolation of nucleic acids and compared the yield of DNA and RNA from free-living and encapsulated microalgae C. sorokiniana. Isolation of nucleic acids from immobilized cells required two steps in dissolving the alginate matrix, releasing the cells, and mechanical disruption with glass beads. For DNA extraction, we used modified versions of a commercial kit along with the hexadecyltrimethylammonium bromide (CTAB) method. For RNA extraction, we used the commercial TRI reagent procedure and the CTAB-dithiotreitol method. Quantity and quality of nucleic acids in extracts varied with growth conditions, isolation procedures, and time of incubation of the original culture. There were consistently higher amounts of DNA and RNA in extracts from immobilized cells. Quantitatively, the modified procedure with the commercial Promega kit was the most reliable procedure for isolating DNA and a modified commercial TRI reagent procedure was the choice for isolating RNA. All four procedures eliminated proteins efficiently and had low levels of contamination from residual polysaccharides from the matrices and/or metabolites naturally produced by the microalgae. All DNA extracts under both growth conditions, time of incubation, and two isolation methods successfully amplified the 18S ribosomal RNA by PCR and quantitative reverse transcription (RT-qPCR). Copyright © 2017 Elsevier B.V. All rights reserved.

  17. [Analysis of the dilution deviation in CA19-9 measurement].

    PubMed

    Hanada, Hiroyuki; Takeoka, Keiko; Nomura, Tomoko; Moriyama, Takanori; Kanakura, Yuzuru

    2005-04-01

    CA19-9 widely used as a tumor marker of the pancreas and a bile duct. There are a number of reports which describes the measured value discrepancies between RIA and non-RIA kits. RIA results also have shown lack of the linearity over 70 U/ml when the samples are diluted. The pH condition at assay reaction for RIA had been suggested as the major reason, it has been denied by the results from the same pH condition at assay reaction used by COBAS CORE CA19-9 EIA II. On the other hand, the lack of RIA antibody titer is indicated for the discordant results by changing the sample volume to reagent volume ratio in the reaction. Our further investigation also indicates that the specific Lewis blood type, i.e. Le (a-b+), shows the linearity issues by RIA. The discrepancies are not caused by the reaction pH, but the amount of the antibody used in the RIA kit is closely associated. Considering the CA19-9 antibody nature used in RIA kit, which covers broad molecular range, users need to pay more attention to setting up each laboratory's measuring range.

  18. Integrating Students of Limited English Proficiency into Standards-Based Reform in the Abbott Districts. Abbott Implementation Resource Guide

    ERIC Educational Resources Information Center

    Lucas, Tamara; Villegas, Ana Maria

    2004-01-01

    In 1999-2000, over one-third of all students in the 30 Abbott districts spoke a native language other than English, and more than one-tenth were considered limited English proficient (LEP). The proportions of LEP students varied considerably across the districts, but they comprised between 5% and 29% of total enrollments in 18 of the districts.…

  19. Maude Abbott and the Origin and Mysterious Disappearance of the Canadian Medical War Museum.

    PubMed

    Wright, James R; Alberti, Samuel J M M; Lyons, Christopher; Fraser, Richard S

    2018-05-07

    - In the early 1900s, it was common practice to retain, prepare, and display instructive pathologic specimens to teach pathology to medical trainees and practitioners; these collections were called medical museums. Maude Abbott established her reputation by developing expertise in all aspects of medical museum work. She was a founder of the International Association of Medical Museums (later renamed the International Academy of Pathology) and became an internationally renowned expert on congenital heart disease. Her involvement in the Canadian Medical War Museum (CMWM) is less well known. - To explore Abbott's role in the development of the CMWM during and after World War I and to trace its history. - Available primary and secondary historical sources were reviewed. - Instructive pathologic specimens derived from Canadian soldiers dying during World War I were shipped to the Royal College of Surgeons in London, which served as a clearinghouse for museum specimens from Dominion forces. The Canadian specimens were repatriated to Canada, prepared by Abbott, and displayed at several medical meetings. Abbott, because she was a woman, could not enlist and so she reported to a series of enlisted physicians with no expertise in museology. Plans for a permanent CMWM building in Ottawa eventually failed and Abbott maintained the collection at McGill (Montreal, Quebec, Canada) until her death in 1940. We trace the CMWM after her death. - Sadly, after Abbott had meticulously prepared these precious teaching specimens so that their previous owners' ultimate sacrifice would continue to help their military brethren, the relics were bureaucratically lost.

  20. HIV status of partners of HIV positive pregnant women in different regions of Nigeria: matters arising.

    PubMed

    Sagay, A S; Onakewhor, J; Galadanci, H; Emuveyan, E E

    2006-12-01

    This study was conducted to determine the pattern of HIV sero-status of Partners of HIV Positive Pregnant Women in three different regions of Nigeria and to explore the implications for HIV prevention interventions. The Site Coordinators of PMTCT programs in three Nigerian cities obtained data of the HIV status of the partners of HIV positive pregnant women. The selection of Benin City, Jos and Kano was made after consideration of their ethnic, religious and cultural representation of Nigeria. Benin City represents a traditional southern Nigeria city, Kano a traditional northern city and Jos, a middle-belt, ethnically diverse cosmopolitan setting. The data were analyzed using frequencies. A total of 500 partners of HIV infected pregnant women were tested for HIV using Determine Abbott test kits. Positive results were confirmed using Western blot or a second rapid test kit. The city-by-city results showed that in Benin City (Southern Nigeria), 78.8% (104/132) of the partners were HIV negative (sero-discordant), Jos (Middle-Belt) had 48.4% (103/213) sero-discordance while Kano (Northern Nigeria) recorded a sero-discordance rate of only 7.7% (12/155). These results indicate that the dynamics of HIV transmission in marital settings in Nigeria are different in the various regions of the country. Socio-cultural and religious settings play a significant role in HIV transmission among couples. These findings should guide prevention interventions in order to achieve maximal impact.

  1. Use of Fructosyl Peptide Oxidase for HbA1c Assay

    PubMed Central

    Yonehara, Satoshi; Inamura, Norio; Fukuda, Miho; Sugiyama, Koji

    2015-01-01

    ARKRAY, Inc developed the world’s first automatic glycohemoglobin analyzer based on HPLC (1981). After that, ARKRAY developed enzymatic HbA1c assay “CinQ HbA1c” with the spread and diversification of HbA1c measurement (2007). CinQ HbA1c is the kit of Clinical Chemistry Analyzer, which uses fructosyl peptide oxidase (FPOX) for a measurement reaction. This report mainly indicates the developmental background, measurement principle, and future of the enzymatic method HbA1c reagent. PMID:25633966

  2. Comparison of the AdvanSure human papillomavirus screening real-time PCR, the Abbott RealTime High Risk human papillomavirus test, and the Hybrid Capture human papillomavirus DNA test for the detection of human papillomavirus.

    PubMed

    Hwang, Yusun; Lee, Miae

    2012-05-01

    We evaluated the performance of various commercial assays for the molecular detection of human papillomavirus (HPV); the recently developed AdvanSure HPV Screening real-time PCR assay (AdvanSure PCR) and the Abbott RealTime High Risk HPV PCR assay (Abbott PCR) were compared with the Hybrid Capture 2 HPV DNA Test (HC2). All 3 tests were performed on 177 samples, and any sample that showed a discrepancy in any of the 3 tests was genotyped using INNO-LiPA HPV genotyping and/or sequencing. On the basis of these results, we obtained a consensus HPV result, and the performance of each test was evaluated. We also evaluated high-risk HPV 16/18 detection by using the 2 real-time PCR assays. Among the 177 samples, 65 were negative and 75 were positive in all 3 assays; however, the results of the 3 assays with 37 samples were discrepant. Compared with the consensus HPV result, the sensitivities and specificities of HC2, AdvanSure PCR, and Abbott PCR were 97.6%, 91.7%, and 86.9% and 83.9%, 98.8%, and 100.0%, respectively. For HPV type 16/18 detection, the concordance rate between the AdvanSure PCR and Abbott PCR assays was 98.3%; however, 3 samples were discrepant (positive in AdvanSure PCR and negative in Abbott PCR) and were confirmed as HPV type 16 by INNO-LiPA genotyping and/or sequencing. For HPV detection, the AdvanSure HPV Screening real-time PCR assay and the Abbott PCR assay are less sensitive but more specific than the HC2 assay, but can simultaneously differentiate type 16/18 HPV from other types.

  3. Clinical evaluation of the Abbott RealTime MTB Assay for direct detection of Mycobacterium tuberculosis-complex from respiratory and non-respiratory samples.

    PubMed

    Hinić, Vladimira; Feuz, Kinga; Turan, Selda; Berini, Andrea; Frei, Reno; Pfeifer, Karin; Goldenberger, Daniel

    2017-05-01

    Rapid and reliable diagnosis is crucial for correct management of tuberculosis. The Abbott RealTime MTB Assay represents a novel qualitative real-time PCR assay for direct detection of M. tuberculosis-complex (MTB) DNA from respiratory samples. The test targets two highly conserved sequences, the multi-copy insertion element IS6110 and the protein antigen B (PAB) gene of MTB, allowing even the detection of IS6610-deficient strains. We evaluated this commercial diagnostic test by analyzing 200 respiratory and, for the first time, 87 non-respiratory clinical specimens from our tertiary care institution and compared its results to our IS6110-based in-house real-time PCR for MTB as well as MTB culture. Overall sensitivity for Abbott RealTime MTB was 100% (19/19) in smear positive and 87.5% (7/8) in smear negative specimens, while the specificity of the assay was 100% (260/260). For both non-respiratory smear positive and smear negative specimens Abbott RealTime MTB tests showed 100% (8/8) sensitivity and 100% (8/8) specificity. Cycle threshold (Ct) value analysis of 16 MTB positive samples showed a slightly higher Ct value of the Abbott RealTime MTB test compared to our in-house MTB assay (mean delta Ct = 2.55). In conclusion, the performance of the new Abbott RealTime MTB Assay was highly similar to culture and in-house MTB PCR. We document successful analysis of 87 non-respiratory samples with the highly automated Abbott RealTime MTB test with no inhibition observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Portable kit for identification and detection of drugs in human urine using surface-enhanced Raman spectroscopy.

    PubMed

    Han, Zhenzhen; Liu, Honglin; Meng, Juan; Yang, Liangbao; Liu, Jing; Liu, Jinhuai

    2015-09-15

    A portable kit was demonstrated for rapid and reliable surface-enhanced Raman scattering (SERS) detection of drugs in human urine. This kit contains two sealed reagent tubes, a packet of standardized SERS substrates, and a mini Raman device. A 3 min pretreatment for separating amphetamines from human urine was developed with an extraction rate of >80% examined by ultraperformance liquid chromatography (UPLC). Simultaneously, highly reproducible two-dimensional (2D) gold nanorod (GNR) arrays were assembled by the use of methoxymercaptopoly(ethylene glycol) (mPEG-SH) capping. Thirty batches of GNR arrays produced the 1001 cm(-1) intensity of methamphetamine (MA) molecules with a relative standard deviation (RSD) of 7.9%, and a 21 × 21 μm(2) area mapping on a 2D GNR array produced a statistical RSD of <10%, implying an excellent reproducibility and uniformity. The detection limit of amphetamines in human urine was at least 0.1 ppm. Moreover, the portable kit was successfully used for detecting MA, 3,4-methylenedioxymethamphetamine (MDMA), and methcathinone (MC) in 30 volunteers' urine samples with various clinical natures, and the dual-analyte detection of MA and MDMA implied a good capability of multiplex analysis. UPLC examination and the SERS recovery test clearly indicated that our pretreatment procedure was sufficient to lower the high background signals caused by complex components in urine and demonstrated the practicability and the resistance to false positives, which is a vital problem for law enforcement applications. The excellent performance of our portable kit promises a great prospective toward a rapid, reliable, and on-spot analyzer, especially for public safety and healthcare.

  5. Multicentric comparative assessment of the bio-evolution Toxoplasma gondii detection kit with eight laboratory-developed PCR assays for molecular diagnosis of congenital toxoplasmosis.

    PubMed

    Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano; Bastien, Patrick

    2015-01-01

    The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. Multicentric Comparative Assessment of the Bio-Evolution Toxoplasma gondii Detection Kit with Eight Laboratory-Developed PCR Assays for Molecular Diagnosis of Congenital Toxoplasmosis

    PubMed Central

    Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano

    2014-01-01

    The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. PMID:25339393

  7. From clinical sample to complete genome: Comparing methods for the extraction of HIV-1 RNA for high-throughput deep sequencing.

    PubMed

    Cornelissen, Marion; Gall, Astrid; Vink, Monique; Zorgdrager, Fokla; Binter, Špela; Edwards, Stephanie; Jurriaans, Suzanne; Bakker, Margreet; Ong, Swee Hoe; Gras, Luuk; van Sighem, Ard; Bezemer, Daniela; de Wolf, Frank; Reiss, Peter; Kellam, Paul; Berkhout, Ben; Fraser, Christophe; van der Kuyl, Antoinette C

    2017-07-15

    The BEEHIVE (Bridging the Evolution and Epidemiology of HIV in Europe) project aims to analyse nearly-complete viral genomes from >3000 HIV-1 infected Europeans using high-throughput deep sequencing techniques to investigate the virus genetic contribution to virulence. Following the development of a computational pipeline, including a new de novo assembler for RNA virus genomes, to generate larger contiguous sequences (contigs) from the abundance of short sequence reads that characterise the data, another area that determines genome sequencing success is the quality and quantity of the input RNA. A pilot experiment with 125 patient plasma samples was performed to investigate the optimal method for isolation of HIV-1 viral RNA for long amplicon genome sequencing. Manual isolation with the QIAamp Viral RNA Mini Kit (Qiagen) was superior over robotically extracted RNA using either the QIAcube robotic system, the mSample Preparation Systems RNA kit with automated extraction by the m2000sp system (Abbott Molecular), or the MagNA Pure 96 System in combination with the MagNA Pure 96 Instrument (Roche Diagnostics). We scored amplification of a set of four HIV-1 amplicons of ∼1.9, 3.6, 3.0 and 3.5kb, and subsequent recovery of near-complete viral genomes. Subsequently, 616 BEEHIVE patient samples were analysed to determine factors that influence successful amplification of the genome in four overlapping amplicons using the QIAamp Viral RNA Kit for viral RNA isolation. Both low plasma viral load and high sample age (stored before 1999) negatively influenced the amplification of viral amplicons >3kb. A plasma viral load of >100,000 copies/ml resulted in successful amplification of all four amplicons for 86% of the samples, this value dropped to only 46% for samples with viral loads of <20,000 copies/ml. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Dog erythrocyte antigens 1.1, 1.2, 3, 4, 7, and Dal blood typing and cross-matching by gel column technique.

    PubMed

    Kessler, Rebecca J; Reese, Jessica; Chang, Denise; Seth, Mayank; Hale, Anne S; Giger, Urs

    2010-09-01

    Testing for canine blood types other than dog erythrocyte antigen 1.1 (DEA 1.1) is controversial and complicated by reagent availability and methodology. The objectives of this study were to use available gel column technology to develop an extended blood-typing method using polyclonal reagents for DEA 1.1, 1.2, 3, 4, 7, and Dal and to assess the use of gel columns for cross-matching. Dogs (43-75) were typed for DEA 1.1, 1.2, 3, 4, 7, and Dal. METHODS included tube agglutination (Tube) using polyclonal reagents, a commercially available DEA 1.1 gel column test kit (Standard-Gel) using monoclonal reagent, and multiple gel columns (Extended-Gel) using polyclonal reagents. Blood from 10 recipient and 15 donor dogs was typed as described above and cross-matched using the gel column technique. Of 43 dogs typed for DEA 1.1, 23, 25, and 20 dogs were positive using Standard-Gel, Extended-Gel, and Tube, respectively. Typing for DEA 1.2 was not achievable with Extended-Gel. For 75 dogs typed for DEA 3, 4, and 7, concordance of Extended-Gel with Tube was 94.7%, 100%, and 84%, respectively. Dal, determined only by Extended-Gel, was positive for all dogs. Post-transfusion major cross-matches were incompatible in 10 of 14 pairings, but none were associated with demonstrable blood type incompatibilities. Gel column methodology can be adapted for use with polyclonal reagents for detecting DEA 1.1, 3, 4, 7, and Dal. Agglutination reactions are similar between Extended-Gel and Tube, but are more easily interpreted with Extended-Gel. When using gel columns for cross-matching, incompatible blood cross-matches can be detected following sensitization by transfusion, although in this study incompatibilities associated with any tested DEA or Dal antigens were not found. ©2010 American Society for Veterinary Clinical Pathology.

  9. [Improvement of laboratory diagnostics of cholera due to genetically altered (hybrid) variants of cholera Vibrio biovar El Tor].

    PubMed

    Savel'eva, I V; Khatsukov, K X; Savel'eva, E I; Moskvitina, S I; Kovalev, D A; Savel'ev, V N; Kulichenko, A N; Antonenko, A D; Babenyshev, B V

    2015-01-01

    Improvement of laboratory diagnostics of cholera taking into the account appearance of hybrid variants of cholera vibrio El Tor biovar in the 1990s. Phenotypic and molecular-genetic properties of typical toxigenic (151 strains) and hybrid (102 strains) variants of El Tor biovar cholera vibrios, isolated in the Caucuses in 1970-1990 and 1993-1998, respectively, were studied. Toxigenicity gene DNA fragments, inherent to El Tor biovars or classic, were detected by using a reagent kit "Genes of Vibrio cholerae variant ctxB-rstR-rstC, REF" developed by us. Reagent kit "Genes of V. cholerae variant ctxB-rstR-rstC, REF" is proposed to be used for laboratory diagnostics of cholera during study of material from humans or environmental objects and for identification of V. cholerae 01 on genome level in PCR-analysis as a necessary addition to the classic scheme of bacteriological analysis. Laboratory diagnostics of cholera due to genetically altered (hybrid) variants of cholera vibrio El Tor biovar is based on a complex study of material from humans and environmental objects by routine bacteriologic and PCR-analysis methods with the aim of detection of gene DNA fragments in the studied material, that determine biovar (classic or El Tor), identification of V. cholerae O1 strains with differentiation of El Tor vibrios into typical and altered, as well as determination of enterotoxin, produced by the specific cholera vibrio strain (by the presence ctxB(El) or ctxB(Cl) gene DNA fragment, coding biosynthesis of CT-2 or CT-1, respectively).

  10. Newborn screening for sickling and other haemoglobin disorders using tandem mass spectrometry: A pilot study of methodology in laboratories in England.

    PubMed

    Daniel, Yvonne A; Henthorn, Joan

    2016-12-01

    To determine (i) if electrospray mass spectrometry-mass spectrometry with the SpOtOn Diagnostics Ltd reagent kit for sickle cell screening could be integrated into the English newborn screening programme, under routine screening conditions, and provide mass spectrometry-mass spectrometry results which match existing methods, and (ii) if common action values could be set for all manufacturers in the study, for all assessed haemoglobins, to indicate which samples require further investigation. Anonymised residual blood spots were analysed using the SpOtOn reagent kit as per manufacturer's instructions, in parallel with existing techniques at four laboratories. Mass spectrometry-mass spectrometry instrumentation at Laboratories A and B was AB Sciex (Warrington, UK) AP4000, and at Laboratories C and D, Waters Micromass (Manchester, UK), Xevo TQMS and Premier, respectively. There were 23,898 results accepted from the four laboratories. Excellent specificity at 100% sensitivity was observed for haemoglobin S, haemoglobin C, haemoglobin E and haemoglobin O Arab . A common action value was not possible for Hb C, but action values were set by manufacturer. The two haemoglobin D Punjab cases at Laboratory D were not detected using the common action value. Conversely, false-positive results with haemoglobin D Punjab were a problem at the remaining three laboratories. This multicentre study demonstrates that it is possible to implement mass spectrometry-mass spectrometry into an established screening programme while maintaining consistency with existing methods for haemoglobinopathy screening. However, one of the instruments investigated cannot be recommended for use with this application. © The Author(s) 2016.

  11. Purification of nanogram-range immunoprecipitated DNA in ChIP-seq application.

    PubMed

    Zhong, Jian; Ye, Zhenqing; Lenz, Samuel W; Clark, Chad R; Bharucha, Adil; Farrugia, Gianrico; Robertson, Keith D; Zhang, Zhiguo; Ordog, Tamas; Lee, Jeong-Heon

    2017-12-21

    Chromatin immunoprecipitation-sequencing (ChIP-seq) is a widely used epigenetic approach for investigating genome-wide protein-DNA interactions in cells and tissues. The approach has been relatively well established but several key steps still require further improvement. As a part of the procedure, immnoprecipitated DNA must undergo purification and library preparation for subsequent high-throughput sequencing. Current ChIP protocols typically yield nanogram quantities of immunoprecipitated DNA mainly depending on the target of interest and starting chromatin input amount. However, little information exists on the performance of reagents used for the purification of such minute amounts of immunoprecipitated DNA in ChIP elution buffer and their effects on ChIP-seq data. Here, we compared DNA recovery, library preparation efficiency, and ChIP-seq results obtained with several commercial DNA purification reagents applied to 1 ng ChIP DNA and also investigated the impact of conditions under which ChIP DNA is stored. We compared DNA recovery of ten commercial DNA purification reagents and phenol/chloroform extraction from 1 to 50 ng of immunopreciptated DNA in ChIP elution buffer. The recovery yield was significantly different with 1 ng of DNA while similar in higher DNA amounts. We also observed that the low nanogram range of purified DNA is prone to loss during storage depending on the type of polypropylene tube used. The immunoprecipitated DNA equivalent to 1 ng of purified DNA was subject to DNA purification and library preparation to evaluate the performance of four better performing purification reagents in ChIP-seq applications. Quantification of library DNAs indicated the selected purification kits have a negligible impact on the efficiency of library preparation. The resulting ChIP-seq data were comparable with the dataset generated by ENCODE consortium and were highly correlated between the data from different purification reagents. This study provides comparative data on commercial DNA purification reagents applied to nanogram-range immunopreciptated ChIP DNA and evidence for the importance of storage conditions of low nanogram-range purified DNA. We verified consistent high performance of a subset of the tested reagents. These results will facilitate the improvement of ChIP-seq methodology for low-input applications.

  12. An rK28-Based Immunoenzymatic Assay for the Diagnosis of Canine Visceral Leishmaniasis in Latin America

    PubMed Central

    Lauricella, Marta Alicia; Maidana, Cristina Graciela; Frias, Victoria Fragueiro; Romagosa, Carlo M.; Negri, Vanesa; Benedetti, Ruben; Sinagra, Angel J.; Luna, Concepcion; Tartaglino, Lilian; Laucella, Susana; Reed, Steven G.; Riarte, Adelina R.

    2016-01-01

    Direct observation of Leishmania parasites in tissue aspirates has shown low sensitivity for the detection of canine visceral leishmaniasis (VL). Therefore in the last quarter century immunoenzymatic tests have been developed to improve diagnosis. The purpose of this study was to develop a fast recombinant K28 antigen, naked-eye qualitative enzyme-linked immunosorbent assay (VL Ql-ELISA) and a quantitative version (VL Qt-ELISA), and to display it in a kit format, whose cutoff value (0.156) was selected as the most adequate one to differentiate reactive from nonreactive samples. Considering 167 cases and 300 controls, sensitivity was 91% for both assays and specificity was 100% and 98.7% in Ql-ELISA and Qt-ELISA, respectively. Positive predictive values were 100% and 97.4% for Ql-ELISA and Qt-ELISA, respectively, and negative predictive values were 95.2% for both ELISAs. Reagent stability, reliability studies, including periodic repetitions and retest of samples, cutoff selection, and comparison of rK28 ELISAs with rK39 immunochromatographic test, were the international criteria that supported the quality in both kits. The performance of both ELISA kits in this work confirmed their validity and emphasized their usefulness for low-to-medium complexity laboratories. PMID:27162270

  13. Spectrophotometric studies of reactions between pseudo-ephedrine with different inorganic and organic reagents and its micro-determination in pure and in pharmaceutical preparations

    NASA Astrophysics Data System (ADS)

    Zayed, M. A.; El-Rasheedy, El-Gazy A.

    2012-03-01

    Two simple, sensitive, cheep and reliable spectrophotometric methods are suggested for micro-determination of pseudoephedrine in its pure form and in pharmaceutical preparation (Sinofree Tablets). The first one depends on the drug reaction with inorganic sensitive reagent like molybdate anion in aqueous media via formation of ion-pair mechanism. The second one depends on the drug reaction with π-acceptor reagent like DDQ in non-aqueous media via formation of charge transfer complex. These reactions were studied under various conditions and the optimum parameters were selected. Under proper conditions the suggested procedures were successfully applied for micro-determination of pseudoephedrine in pure and in Sinofree Tablets without interference from excepients. The values of SD, RSD, recovery %, LOD, LOQ and Sandell sensitivity refer to the high accuracy and precession of the applied procedures. The results obtained were compared with the data obtained by an official method, referring to confidence and agreement with DDQ procedure results; but it referred to the more accuracy of the molybdate data. Therefore, the suggested procedures are now successfully being applied in routine analysis of this drug in its pharmaceutical formulation (Sinofree) in Saudi Arabian Pharmaceutical Company (SPIMACO) in Boridah El-Qaseem, Saudi Arabia instead of imported kits had been previously used.

  14. Evaluation of a novel semi-automated HPLC procedure for whole blood cyclosporin A confirms equivalence to adjusted monoclonal values from Abbott TDx.

    PubMed

    Roberts, Norman B; Dutton, John; Higgins, Gerald; Allars, Lesley

    2005-01-01

    The problem in the measurement of cyclosporin (CyA) is that the widely used immuno-based assays suffer from interference by metabolites present in unpredictable excess. To resolve this, the consensus view has been to develop more specific and robust procedures for the measurement of CyA alone in order to give values similar to those obtained by HPLC. We developed an alternative strategy based on Abbott poly- and monoclonal assays to derive an adjusted monoclonal value as an equivalent measurement to HPLC. We have now evaluated a recently developed semi-automated HPLC procedure and used it to test the validity of the adjusted monoclonal value. The automated HPLC procedure with online clean-up was optimised for the separation of CyA and internal standard CyD. The assay was simple to use, precise and gave good recovery of cyclosporin from whole blood. Comparisons with the more specific immunoassays Abbott AxSym and EMIT showed close agreement, whereas Abbott monoclonal values indicated up to 20% positive bias. In contrast, the adjusted monoclonal values gave good agreement with HPLC. Data obtained from HPLC linked to tandem mass spectrometry (MS) indicated closer agreement with Abbott monoclonal values than expected, suggesting some positive bias with MS. The benefit of using an adjusted monoclonal value is that a result equivalent to HPLC is obtained, as well as an indication of the concentration of metabolites from the Abbott polyclonal measurement.

  15. Analytical and clinical performance characteristics of the Abbott RealTime MTB RIF/INH Resistance, an assay for the detection of rifampicin and isoniazid resistant Mycobacterium tuberculosis in pulmonary specimens.

    PubMed

    Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong

    2016-12-01

    Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  16. [Efficient extraction of transmembrane proteins using ProteoExtract Transmembrane Protein Extraction Kit].

    PubMed

    Błachnio, Karina

    2010-01-01

    Detergents commonly used for solubilization of membrane proteins may be ionic or non-ionic. Exposing membrane proteins to detergents, however, can adversely affect their native structure, which can be a major hindrance for functional studies. This is especially true for proteins with multiple transmembrane domains. The ProteoExtract Transmembrane Protein Extraction Kit (TM-PEK), offered by Merck, provides a detergent-free novel reagents to enable the mild and efficient extraction of proteins containing seven transmembrane domains, such as GPCRs (G-Protein Coupled Receptors) e.g.: Frizzled-4 and CELSR-3, from mammalian cells. The fraction enriched in transmembrane proteins using TM-PEK is directly compatible with enzyme assays, non-denaturing gel electrophoresis, 1- and 2-D SDS-PAGE, MS analysis, Western blotting, immunoprecipitation and ELISA. Unlike many alternatives, TM-PEK extraction procedure does not require sonication, extended rigorous vortexing, ultracentrifugation, or incubation of samples at elevated temperatures--thus minimizing the risk of post-extraction degradation or modifications.

  17. 75 FR 8398 - Agency Information Collection Activities; Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-24

    ... Marilyn R. Abbott, Secretary to the Commission, U.S. International Trade Commission, 500 E Street, SW... complete. By order of the Commission. February 19, 2010. Marilyn R. Abbott, Secretary to the Commission...

  18. Abbott Opinions #1-5.

    ERIC Educational Resources Information Center

    Education Law Center, Inc., Newark, NJ.

    This document contains the following "Abbott Opinions": (1) "Early Childhood Education"; (2) "Adequate School Facilities"; (3) "Supplemental Programs and Whole School Reform in Elementary Schools"; (4) "Supplemental Programs in Middle and High Schools"; and (5) "Planning Programs and Budgets…

  19. A Comparative Study of Serum Exosome Isolation Using Differential Ultracentrifugation and Three Commercial Reagents.

    PubMed

    Helwa, Inas; Cai, Jingwen; Drewry, Michelle D; Zimmerman, Arthur; Dinkins, Michael B; Khaled, Mariam Lotfy; Seremwe, Mutsa; Dismuke, W Michael; Bieberich, Erhard; Stamer, W Daniel; Hamrick, Mark W; Liu, Yutao

    2017-01-01

    Exosomes play a role in cell-to-cell signaling and serve as possible biomarkers. Isolating exosomes with reliable quality and substantial concentration is a major challenge. Our purpose is to compare the exosomes extracted by three different exosome isolation kits (miRCURY, ExoQuick, and Invitrogen Total Exosome Isolation Reagent) and differential ultracentrifugation (UC) using six different volumes of a non-cancerous human serum (5 ml, 1 ml, 500 μl, 250 μl, 100 μl, and 50 μl) and three different volumes (1 ml, 500 μl and 100 μl) of six individual commercial serum samples collected from human donors. The smaller starting volumes (100 μl and 50 μl) are used to mimic conditions of limited availability of heterogeneous biological samples. The isolated exosomes were characterized based upon size, quantity, zeta potential, CD63 and CD9 protein expression, and exosomal RNA (exRNA) quality and quantity using several complementary methods: nanoparticle tracking analysis (NTA) with ZetaView, western blot, transmission electron microscopy (TEM), the Agilent Bioanalyzer system, and droplet digital PCR (ddPCR). Our NTA results showed that all isolation techniques produced exosomes within the expected size range (40-150 nm). The three kits, though, produced a significantly higher yield (80-300 fold) of exosomes as compared to UC for all serum volumes, except 5 mL. We also found that exosomes isolated by the different techniques and serum volumes had similar zeta potentials to previous studies. Western blot analysis and TEM immunogold labelling confirmed the expression of two common exosomal protein markers, CD63 and CD9, in samples isolated by all techniques. All exosome isolations yielded high quality exRNA, containing mostly small RNA with a peak between 25 and 200 nucleotides in size. ddPCR results indicated that exosomes isolated from similar serum volumes but different isolation techniques rendered similar concentrations of two selected exRNA: hsa-miR-16 and hsa-miR-451. In summary, the three commercial exosome isolation kits are viable alternatives to UC, even when limited amounts of biological samples are available.

  20. Evaluation of the PrioCHECK™ Trichinella AAD Kit for the digestion and recovery of larvae in pork, horse meat and wild meat.

    PubMed

    Konecsni, Kelly; Scheller, Cheryl; Scandrett, Brad; Buholzer, Patrik; Gajadhar, Alvin

    2017-08-30

    The artificial digestion magnetic stirrer method using pepsin protease and hydrochloric acid is the standard assay for the detection of Trichinella larvae in muscle of infected animals. Recently, an alternative enzyme, serine protease, was employed in the development of a commercially available digestion kit (PrioCHECK™ Trichinella AAD Kit). This assay requires a higher digestion temperature of 60°C which kills the larvae during the digestion process, mitigating the risk of environmental contamination from the parasite. The present study was conducted to determine the performance of the PrioCHECK™ Trichinella AAD Kit compared to the conventional pepsin/HCl digestion. Replicate paired 115g samples of Trichinella-negative pork diaphragm and masseter, and of horse tongue and masseter, were used to compare the two methods for tissue digestibility. Similarly, paired 100g samples of pork diaphragm and horse tongue were spiked with proficiency samples containing known numbers of Trichinella spiralis first stage larvae to compare larval recoveries for the two methods. Masseter samples from wild bears and wolves naturally infected with Trichinella nativa or T6 were also used to compare the performance of the methods. The results of the study showed that the PrioCHECK™ Trichinella AAD Kit, when used according to the manufacturer's instructions, was effective in detecting Trichinella infection in all samples that contained 0.05 or more larvae per gram of tissue. Although there was no significant difference between the Kit method and the standard pepsin/HCl digestion procedure in the average number of larvae recovered from spiked pork diaphragm, 38% fewer larvae were recovered from similarly spiked samples of horse tongue by digestion using serine protease (one way ANOVA, P value <0.001). Additional clarification was also more often required for both horse meat and pork when using the Kit compared to the pepsin/HCl method. The results of testing wildlife samples were similar for the two methods. Overall, the performance of the Kit method was suitable for the digestion of muscle samples and recovery of Trichinella larvae, according to international standards. It also provides advantages of faster digestion, safer reagents and recovered parasites that are non-hazardous for analysts and the environment. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  1. Rapid Detection of the Varicella Zoster Virus

    NASA Technical Reports Server (NTRS)

    Lewis, Michelle P.; Harding, Robert

    2011-01-01

    1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.

  2. The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases.

    PubMed

    Wang, Linchuan; Chen, Wei; Yu, Yan

    2017-01-01

    To date, there is a trend that the chemiluminescent microparticle immunoassays (CMIA) and electrochemiluminescence immunoassays (ECIA) technology gradually replacing the enzyme-linked immunosorbent assay (ELISA). But the performance such as the limit of quantitation (LOQ), precision, linear range of CMIA, or ECIA for serum markers of infectious diseases has rarely been reported. Using proficiency testing samples and standard materials, we confirmed the LOQ of the ELISA and the precision, linear range, LOQ, and instrument biases of the Abbott i2000 for eight serum markers. We used the Abbott i2000 and ELISAs to assess five HIV samples; the researchers were blinded to the true status of the samples. For the Abbott i2000, the coefficients of variation (CV) for the low, medium, and high concentration samples ranged from 1.06 to 12.74%, which were less than the allowable error; the linear ranges of HBsAg and HBsAb were 0.66-304.11 IU/ml and 8.16-1205.9 mIU/ml, respectively. For the Abbott i2000, the LOQs of HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, anti-HCV, anti-TP, and anti-HIV were 0.026 IU/ml, 4 mIU/ml, 0.14 NCU/ml, 0.56 NCU/ml, 0.99 NCU/ml, 0.5 NCU/ml, 8.8 mIU/ml, and 1.92 NCU/ml, respectively, and these values were 0.16 IU/ml, 6.97 mIU/ml, 1.16 NCU/ml, 1.63 NCU/ml, 1.79 NCU/ml, 1.03 NCU/ml, 8.33 mIU/ml, and 1.3 NCU/ml, respectively, for the ELISA. When five HIV samples were blindly assessed, two cases were missed by the Abbott i2000 and the ELISA results were consistent with the expected results. The Abbott i2000 performed significantly better than the ELISA on HBV and HCV screening; however, for anti-TP and anti-HIV, the ELISA remained the preferred method. © 2016 Wiley Periodicals, Inc.

  3. Evaluation of the Abbott Real Time HCV genotype II assay for Hepatitis C virus genotyping.

    PubMed

    Sariguzel, Fatma Mutlu; Berk, Elife; Gokahmetoglu, Selma; Ercal, Baris Derya; Celik, Ilhami

    2015-01-01

    The determination of HCV genotypes and subtypes is very important for the selection of antiviral therapy and epidemiological studies. The aim of this study was to evaluate the performance of Abbott Real Time HCV Genotype II assay in HCV genotyping of HCV infected patients in Kayseri, Turkey. One hundred patients with chronic hepatitis C admitted to our hospital were evaluated between June 2012 and December 2012, HCV RNA levels were determined by the COBAS® AmpliPrep/COBAS® TaqMan® 48 HCV test. HCV genotyping was investigated by the Abbott Real Time HCV Genotype II assay. With the exception of genotype 1, subtypes of HCV genotypes could not be determined by Abbott assay. Sequencing analysis was used as the reference method. Genotypes 1, 2, 3 and 4 were observed in 70, 4, 2 and 24 of the 100 patients, respectively, by two methods. The concordance between the two systems to determine HCV major genotypes was 100%. Of 70 patients with genotype 1, 66 showed infection with subtype 1b and 4 with subtype 1a by Abbott Real Time HCV Genotype II assay. Using sequence analysis, 61 showed infection with subtype 1b and 9 with subtype 1a. In determining of HCV genotype 1 subtypes, the difference between the two methods was not statistically significant (P>0.05). HCV genotype 4 and 3 samples were found to be subtype 4d and 3a, respectively, by sequence analysis. There were four patients with genotype 2. Sequence analysis revealed that two of these patients had type 2a and the other two had type 2b. The Abbott Real Time HCV Genotype II assay yielded results consistent with sequence analysis. However, further optimization of the Abbott Real Time HCV Genotype II assay for subtype identification of HCV is required.

  4. Trypanocidal constituents in plants 4. Withanolides from the aerial parts of Physalis angulata.

    PubMed

    Nagafuji, Shinya; Okabe, Hikaru; Akahane, Hiroshige; Abe, Fumiko

    2004-02-01

    The constituents of the aerial parts of Physalis angulata (Solanaceae) were investigated based on the plant's trypanocidal activity against epimastigotes of Trypanosoma cruzi, the etiologic agent for Chagas' disease. Four new withanolides were isolated, along with six known ones, from the active fraction. Their structures were determined by spectroscopic analysis. Trypanocidal activity against trypomastigotes, an infectious form of T. cruzi, was also estimated, as well as cytotoxic activity against human uterine carcinoma (HeLa) cells in vitro. Evaluation of trypanocidal activity using the colorimetric reagent Cell Counting Kit-8 was also examined.

  5. Workflow and maintenance characteristics of five automated laboratory instruments for the diagnosis of sexually transmitted infections.

    PubMed

    Ratnam, Sam; Jang, Dan; Gilchrist, Jodi; Smieja, Marek; Poirier, Andre; Hatchette, Todd; Flandin, Jean-Frederic; Chernesky, Max

    2014-07-01

    The choice of a suitable automated system for a diagnostic laboratory depends on various factors. Comparative workflow studies provide quantifiable and objective metrics to determine hands-on time during specimen handling and processing, reagent preparation, return visits and maintenance, and test turnaround time and throughput. Using objective time study techniques, workflow characteristics for processing 96 and 192 tests were determined on m2000 RealTime (Abbott Molecular), Viper XTR (Becton Dickinson), cobas 4800 (Roche Molecular Diagnostics), Tigris (Hologic Gen-Probe), and Panther (Hologic Gen-Probe) platforms using second-generation assays for Chlamydia trachomatis and Neisseria gonorrhoeae. A combination of operational and maintenance steps requiring manual labor showed that Panther had the shortest overall hands-on times and Viper XTR the longest. Both Panther and Tigris showed greater efficiency whether 96 or 192 tests were processed. Viper XTR and Panther had the shortest times to results and m2000 RealTime the longest. Sample preparation and loading time was the shortest for Panther and longest for cobas 4800. Mandatory return visits were required only for m2000 RealTime and cobas 4800 when 96 tests were processed, and both required substantially more hands-on time than the other systems due to increased numbers of return visits when 192 tests were processed. These results show that there are substantial differences in the amount of labor required to operate each system. Assay performance, instrumentation, testing capacity, workflow, maintenance, and reagent costs should be considered in choosing a system. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  6. The pivotal role of fibrocytes and mast cells in mediating fibrotic reactions to biomaterials

    PubMed Central

    Thevenot, Paul T.; Baker, David W.; Weng, Hong; Sun, Man-Wu; Tang, Liping

    2011-01-01

    Almost all biomaterial implants are surrounded by a fibrotic capsule, although the mechanism of biomaterial-mediated fibrotic reactions is mostly unclear. To search for the types of cells responsible for triggering the tissue responses, we used poly-L glycolic acid polymers capable of releasing various reagents. We first identified that CD45+ /Collagen 1+ fibrocytes are recruited and resided within the fibrotic capsule at the implant interface. Interestingly, we found that the recruitment of fibrocytes and the extent of fibrotic tissue formation (collagen type I production) were substantially enhanced and reduced by the localized release of compound 48/80 and cromolyn, respectively. Since it is well established that compound 48/80 and cromolyn alter mast cell reactions, we hypothesized that mast cells are responsible for triggering fibrocyte recruitment and subsequent fibrotic capsule formation surrounding biomaterial implants. To directly test this hypothesis, similar studies were carried out using mast cell deficient mice, WBB6F1/J-KitW/KitW-v/, and their congenic controls. Indeed, mast cell deficient mice prompted substantially less fibrocyte and myofibroblast responses in comparison to C-57 wild type mice controls. Most interestingly, subcutaneous mast cell reconstitution of WBB6F1/J-KitW/KitW-v/J mice almost completely restored the fibrocyte response in comparison to the C-57 wild type response. These results indicate that the initial biomaterial interaction resulting in the stimulation of mast cells and degranulation byproducts not only stimulates the inflammatory cascade but significantly alters the downstream fibrocyte response and degree of fibrosis. PMID:21864899

  7. Ballast water compliance monitoring: A new application for ATP

    NASA Astrophysics Data System (ADS)

    Lo Curto, A.; Stehouwer, P.; Gianoli, C.; Schneider, G.; Raymond, M.; Bonamin, V.

    2018-03-01

    The coming into force of the USCG ballast water regulations and the IMO ballast water management convention resulted in the development of several technologies approved for the treatment of ballast water. To ensure compliance of these technologies, the development of rapid and robust analysis methods was necessary. In collaboration with the SGS Group (Switzerland) and LuminUltra (Canada), Aqua-tools (France) has developed an innovative Ballast Water Treatment Monitoring (BWTM) kit for rapid onboard testing. The affordable kit provides results in less than 1 h, is easy to use and durable ensuring that the ballast water treatment system on the ship is fully compliant with the discharge standards upon arrival in port. The core of this method is a combination of high-quality reagents (lysis solution and ATP 2G Luminase™ enzyme) not inhibited by salinity and a patented fast homogenizing method for ATP extraction developed for a higher ATP recovery from zooplankton and phytoplankton. Compared to traditional analysis methods, the BWTM Kit provides fast and accurate results for all three fractions of microorganisms (≥ 50 μm, ≥ 10 ÷ < 50 μm and bacteria). Preliminary tests carried out in cooperation with SGS showed that the proposed method was able to detect onboard the efficiency of the treatment systems used. Compliance limits were established for all size fractions and a correlation between the standard methods (microscopy, plate count, MPN) and ATP was evaluated. The BWTM kit can provide a fast indication of compliance or gross exceedance. The rare borderline cases, when encountered, of course require additional confirmation.

  8. Development and Analytical Validation of an Immunoassay for Quantifying Serum Anti-Pertussis Toxin Antibodies Resulting from Bordetella pertussis Infection ▿

    PubMed Central

    Menzies, Sandra L.; Kadwad, Vijay; Pawloski, Lucia C.; Lin, Tsai-Lien; Baughman, Andrew L.; Martin, Monte; Tondella, Maria Lucia C.; Meade, Bruce D.

    2009-01-01

    Adequately sensitive and specific methods to diagnose pertussis in adolescents and adults are not widely available. Currently, no Food and Drug Administration-approved diagnostic assays are available for the serodiagnosis of Bordetella pertussis. Since concentrations of B. pertussis-specific antibodies tend to be high during the later phases of disease, a simple, rapid, easily transferable serodiagnostic test was developed. This article describes test development, initial evaluation of a prototype kit enzyme-linked immunosorbent assay (ELISA) in an interlaboratory collaborative study, and analytical validation. The data presented here demonstrate that the kit met all prespecified criteria for precision, linearity, and accuracy for samples with anti-pertussis toxin (PT) immunoglobulin G (IgG) antibody concentrations in the range of 50 to 150 ELISA units (EU)/ml, the range believed to be most relevant for serodiagnosis. The assay met the precision and linearity criteria for a wider range, namely, from 50 to 200 EU/ml; however, the accuracy criterion was not met at 200 EU/ml. When the newly adopted World Health Organization International Standard for pertussis antiserum (human) reference reagent was used to evaluate accuracy, the accuracy criteria were met from 50 to 200 international units/ml. In conclusion, the IgG anti-PT ELISA met all assay validation parameters within the range considered most relevant for serodiagnosis. This ELISA was developed and analytically validated as a user-friendly kit that can be used in both qualitative and quantitative formats. The technology for producing the kit is transferable to public health laboratories. PMID:19864485

  9. Comparison of the Abbott m2000 HIV-1 Real-Time and Roche AMPLICOR Monitor v1.5 HIV-1 assays on plasma specimens from Rakai, Uganda.

    PubMed

    Ssebugenyi, I; Kizza, A; Mpoza, B; Aluma, G; Boaz, I; Newell, K; Laeyendecker, O; Shott, J P; Serwadda, D; Reynolds, S J

    2011-07-01

    The need for viral load (VL) monitoring of HIV patients receiving antiretroviral therapy (ART) in resource-limited settings (RLS) has become apparent with studies showing the limitations of immunological monitoring. We compared the Abbott m2000 Real-Time (Abbott) HIV-1 assay with the Roche AMPLICOR Monitor v1.5 (Roche) HIV-1 assay over a range of VL concentrations. Three hundred and eleven plasma samples were tested, including 164 samples from patients on ART ≥ six months and 147 from ART-naïve patients. The Roche assay detected ≥400 copies/mL in 158 (50.8%) samples. Of these, Abbott produced 145 (91.8%) detectable results ≥400 copies/mL; 13 (8.2%) samples produced discrepant results. Concordance between the assays for detecting HIV-1 RNA ≥400 copies/mL was 95.8% (298/311). The sensitivity, specificity, positive predictive value and negative predictive value of Abbott to detect HIV-1 RNA ≥400 copies/mL were 91.8%, 100%, 100% and 92.2%, respectively. For the 151 samples with HIV-1 RNA ≥400 copies/mL for both assays, a good linear correlation was found (r = 0.81, P < 0.0001; mean difference, 0.05). The limits of agreement were -0.97 and 1.07 log(10) copies/mL (mean ± 2 SD). The Abbott assay performed well in our setting, offering an alternative methodology for HIV-1 VL for laboratories with realtime polymerase chain reaction (PCR) capacity.

  10. 75 FR 10815 - Notice of Proposed Withdrawal Extension and Opportunity for Public Meeting; Oregon

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-09

    ... ecological research values at the Abbott Creek Research Natural Area. The withdrawal created by PLO No. 6856... the protection of the unique natural and ecological research values at the Abbott Creek Research...

  11. 76 FR 383 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-04

    ... interest issues raised by the complaint. FOR FURTHER INFORMATION CONTACT: Marilyn R. Abbott, Secretary to... Commission. Issued: December 28, 2010. Marilyn R. Abbott, Secretary to the Commission. [FR Doc. 2010-33131...

  12. 76 FR 5204 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-28

    .... Abbott, Secretary to the Commission, U.S. International Trade Commission, 500 E Street, SW., Washington...)(4)). Issued: January 24, 2011. By order of the Commission. Marilyn R. Abbott. Secretary to the...

  13. 75 FR 69703 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    .... Abbott, Secretary to the Commission, U.S. International Trade Commission, 500 E Street, SW., Washington... Commission. Issued: November 5, 2010. Marilyn R. Abbott, Secretary to the Commission. [FR Doc. 2010-28625...

  14. 76 FR 4722 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ... public interest issues raised by the complaint. FOR FURTHER INFORMATION CONTACT: Marilyn R. Abbott...)(4)). By order of the Commission. Issued: January 21, 2011. Marilyn R. Abbott, Secretary to the...

  15. 8. DETAIL OF END BEARING CONDITION AT SOUTHWEST CORNER OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. DETAIL OF END BEARING CONDITION AT SOUTHWEST CORNER OF BRIDGE, SHOWING METAL ENCASED CIRCULAR CONCRETE PILING AND FIXED SHOE - Abbott's Parker Through Truss Bridge, Spanning Sandusky River at Abbott Road (Pleasant Township), Tiffin, Seneca County, OH

  16. 75 FR 48724 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    ... any public interest issues raised by the complaint. FOR FURTHER INFORMATION CONTACT: Marilyn Abbott... Commission. Marilyn R. Abbott, Secretary to the Commission. [FR Doc. 2010-19763 Filed 8-10-10; 8:45 am...

  17. 75 FR 53710 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-01

    ...: Marilyn R. Abbott, Secretary to the Commission, U.S. International Trade Commission, 500 E Street, SW... Commission. Issued: August 26, 2010. Marilyn R. Abbott, Secretary to the Commission. [FR Doc. 2010-21789...

  18. A checklist of the vascular plants in Abbott Creek Research Natural Area, Oregon.

    Treesearch

    Rod Mitchell

    1979-01-01

    This paper is a checklist of 277 vascular plant taxa that have been collected or encountered in Abbott Creek Research Natural Area, Oregon; a brief description of five forested and two nonforested vegetation types is included.

  19. The impact of change in albumin assay on reference intervals, prevalence of 'hypoalbuminaemia' and albumin prescriptions.

    PubMed

    Coley-Grant, Deon; Herbert, Mike; Cornes, Michael P; Barlow, Ian M; Ford, Clare; Gama, Rousseau

    2016-01-01

    We studied the impact on reference intervals, classification of patients with hypoalbuminaemia and albumin infusion prescriptions on changing from a bromocresol green (BCG) to a bromocresol purple (BCP) serum albumin assay. Passing-Bablok regression analysis and Bland-Altman plot were used to compare Abbott BCP and Roche BCG methods. Linear regression analysis was used to compare in-house and an external laboratory Abbott BCP serum albumin results. Reference intervals for Abbott BCP serum albumin were derived in two different laboratories using pathology data from adult patients in primary care. Prescriptions for 20% albumin infusions were compared one year before and one year after changing the albumin method. Abbott BCP assay had a negative bias of approximately 6 g/L compared with Roche BCG method.There was good agreement (y = 1.04 x - 1.03; R(2 )= 0.9933) between in-house and external laboratory Abbott BCP results. Reference intervals for the serum albumin Abbott BCP assay were 31-45 g/L, different to those recommended by Pathology Harmony and the manufacturers (35-50 g/L). Following the change in method there was a large increase in the number of patients classified as hypoalbuminaemic using Pathology Harmony references intervals (32%) but not when retrospectively compared to locally derived reference intervals (16%) compared with the previous year (12%). The method change was associated with a 44.6% increase in albumin prescriptions. This equated to an annual increase in expenditure of £35,234. We suggest that serum albumin reference intervals be method specific to prevent misclassification of albumin status in patients. Change in albumin methodology may have significant impact on hospital resources. © The Author(s) 2015.

  20. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry.

    PubMed

    Kocak, Fatma Emel; Ozturk, Bahadir; Isiklar, Ozben Ozden; Genc, Ozlem; Unlu, Ali; Altuntas, Irfan

    2015-01-01

    Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS). One hundred venous blood samples were randomly selected from routine vitamin D tests. Two of the serum aliquots were analyzed at the Abbott Architect i2000 and the Roche Cobas 6000's module e601 in our laboratory within the same day. The other serum aliquots were analyzed at the LC-MS/MS in different laboratory. Passing-Bablok regression analysis and Bland-Altman plot were used to compare methods. Inter-rater agreement was analyzed using kappa (κ) analysis. The Roche assay showed acceptable agreement with the LC-MS/MS based on Passing-Bablok analysis (intercept: -5.23 nmol/L, 95% CI: -8.73 to 0.19; slope: 0.97, 95% CI: 0.77 to 1.15). The Abbott assay showed proportional (slope: 0.77, 95% CI: 0.67 to 0.85) and constant differences (intercept: 17.08 nmol/L; 95% CI: 12.98 to 21.39). A mean bias of 15.1% was observed for the Abbott and a mean bias of -14.1% was observed for the Roche based on the Bland-Altman plots. We found strong to nearly perfect agreement in vitamin D status between the immunoassays and LC-MS/MS. (κ: 0.83 for Abbott, κ: 0.93 for Roche) using kappa analysis. Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.

  1. Evaluation of the clinical performance of the Abbott RealTime High-Risk HPV for carcinogenic HPV detection.

    PubMed

    Halfon, Philippe; Benmoura, Dominique; Agostini, Aubert; Khiri, Hacene; Penaranda, Guillaume; Martineau, Agnes; Blanc, Bernard

    2010-08-01

    Abbott RealTime (RT) High-Risk (HR) HPV assay is a new qualitative real-time polymerase chain reaction (PCR) based assay for the detection of 14 HR HPV DNA. The assay can differentiate between the infection by HPV 16, HPV 18 and non-HPV 16/18 types through the distinct fluorescent labels on the type specific probes. To evaluate the clinical performance of the Abbott RT HR HPV test, in comparison with biopsy, Hybrid Capture II (HCII), and Linear Array (LA), for detection of high-grade disease (CIN2+). The study population consisted of 143 women who were included in three referral gynecology clinics in Marseilles (France) between March 2007 and June 2008. The clinical performance of the RT HR HPV assay, performed on the fully automated m2000 system, was compared with HCII and LA. HR HPV positivity rate was similar for all tests (Abbott RT HR HPV and HCII, 62%, and LA 63%). All tests had high sensitivities and negative predictive values for CIN2+ detection (>90%). The agreement between HCII and Abbott RT HR HPV, and between HCII and LA were 93% (k=0.85) and 96% (k=0.91) respectively. As expected, HPV16 or HPV18 positivity was greater in advanced grades of disease, especially in CIN2+ patients: 85% in CIN2+ vs. 33% in

  2. Comparison of the Chiron Quantiplex branched DNA (bDNA) assay and the Abbott Genostics solution hybridization assay for quantification of hepatitis B viral DNA.

    PubMed

    Kapke, G E; Watson, G; Sheffler, S; Hunt, D; Frederick, C

    1997-01-01

    Several assays for quantification of DNA have been developed and are currently used in research and clinical laboratories. However, comparison of assay results has been difficult owing to the use of different standards and units of measurements as well as differences between assays in dynamic range and quantification limits. Although a few studies have compared results generated by different assays, there has been no consensus on conversion factors and thorough analysis has been precluded by small sample size and limited dynamic range studied. In this study, we have compared the Chiron branched DNA (bDNA) and Abbott liquid hybridization assays for quantification of hepatitis B virus (HBV) DNA in clinical specimens and have derived conversion factors to facilitate comparison of assay results. Additivity and variance stabilizing (AVAS) regression, a form of non-linear regression analysis, was performed on assay results for specimens from HBV clinical trials. Our results show that there is a strong linear relationship (R2 = 0.96) between log Chiron and log Abbott assay results. Conversion factors derived from regression analyses were found to be non-constant and ranged from 6-40. Analysis of paired assay results below and above each assay's limit of quantification (LOQ) indicated that a significantly (P < 0.01) larger proportion of observations were below the Abbott assay LOQ but above the Chiron assay LOQ, indicating that the Chiron assay is significantly more sensitive than the Abbott assay. Testing of replicate specimens showed that the Chiron assay consistently yielded lower per cent coefficients of variance (% CVs) than the Abbott assay, indicating that the Chiron assay provides superior precision.

  3. AUTOMATED BIOCHEMICAL IDENTIFICATION OF BACTERIAL FISH PATHOGENS USING THE ABBOTT QUANTUM II

    EPA Science Inventory

    The Quantum II, originally designed by Abbott Diagnostics for automated rapid identification of members of Enterobacteriaceae, was adapted for the identification of bacterial fish pathogens. he instrument operates as a spectrophotometer at a wavelength of 492.600 nm. ample cartri...

  4. 75 FR 78266 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-15

    ... interest issues raised by the complaint. FOR FURTHER INFORMATION CONTACT: Marilyn R. Abbott, Secretary to...: December 9, 2010. Marilyn R. Abbott Secretary to the Commission [FR Doc. 2010-31395 Filed 12-14-10; 8:45 am...

  5. 42. Peaks of Otter, Abbott Lake. View across lake to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. Peaks of Otter, Abbott Lake. View across lake to peaks of Outter Lodge, completed in 1964. Construction of the lake got underway in 1964. Looking east-northeast. - Blue Ridge Parkway, Between Shenandoah National Park & Great Smoky Mountains, Asheville, Buncombe County, NC

  6. Toxic reagents and expensive equipment: are they really necessary for the extraction of good quality fungal DNA?

    PubMed

    Rodrigues, P; Venâncio, A; Lima, N

    2018-01-01

    The aim of this work was to evaluate a fungal DNA extraction procedure with the lowest inputs in terms of time as well as of expensive and toxic chemicals, but able to consistently produce genomic DNA of good quality for PCR purposes. Two types of fungal biological material were tested - mycelium and conidia - combined with two protocols for DNA extraction using Sodium Dodecyl Sulphate (SDS) and Cetyl Trimethyl Ammonium Bromide as extraction buffers and glass beads for mechanical disruption of cell walls. Our results showed that conidia and SDS buffer was the combination that lead to the best DNA quality and yield, with the lowest variation between samples. This study clearly demonstrates that it is possible to obtain high yield and pure DNA from pigmented conidia without the use of strong cell disrupting procedures and of toxic reagents. There are numerous methods for DNA extraction from fungi. Some rely on expensive commercial kits and/or equipments, unavailable for many laboratories, or make use of toxic chemicals such as chloroform, phenol and mercaptoethanol. This study clearly demonstrates that it is possible to obtain high yields of pure DNA from pigmented conidia without the use of strong and expensive cell disrupting procedures and of toxic reagents. The method herein described is simultaneously inexpensive and adequate to DNA extraction from several different types of fungi. © 2017 The Society for Applied Microbiology.

  7. Methods for the extraction and RNA profiling of exosomes

    PubMed Central

    Zeringer, Emily; Li, Mu; Barta, Tim; Schageman, Jeoffrey; Pedersen, Ketil Winther; Neurauter, Axl; Magdaleno, Susan; Setterquist, Robert; Vlassov, Alexander V

    2013-01-01

    AIM: To develop protocols for isolation of exosomes and characterization of their RNA content. METHODS: Exosomes were extracted from HeLa cell culture media and human blood serum using the Total exosome isolation (from cell culture media) reagent, and Total exosome isolation (from serum) reagent respectively. Identity and purity of the exosomes was confirmed by Nanosight® analysis, electron microscopy, and Western blots for CD63 marker. Exosomal RNA cargo was recovered with the Total exosome RNA and protein isolation kit. Finally, RNA was profiled using Bioanalyzer and quantitative reverse transcription-polymerase chain reaction (qRT-PCR) methodology. RESULTS: Here we describe a novel approach for robust and scalable isolation of exosomes from cell culture media and serum, with subsequent isolation and analysis of RNA residing within these vesicles. The isolation procedure is completed in a fraction of the time, compared to the current standard protocols utilizing ultracentrifugation, and allows to recover fully intact exosomes in higher yields. Exosomes were found to contain a very diverse RNA cargo, primarily short sequences 20-200 nt (such as miRNA and fragments of mRNA), however longer RNA species were detected as well, including full-length 18S and 28S rRNA. CONCLUSION: We have successfully developed a set of reagents and a workflow allowing fast and efficient extraction of exosomes, followed by isolation of RNA and its analysis by qRT-PCR and other techniques. PMID:25237619

  8. Spectrophotometric studies of reactions between pseudo-ephedrine with different inorganic and organic reagents and its micro-determination in pure and in pharmaceutical preparations.

    PubMed

    Zayed, M A; El-Rasheedy, El-Gazy A

    2012-03-01

    Two simple, sensitive, cheep and reliable spectrophotometric methods are suggested for micro-determination of pseudoephedrine in its pure form and in pharmaceutical preparation (Sinofree Tablets). The first one depends on the drug reaction with inorganic sensitive reagent like molybdate anion in aqueous media via formation of ion-pair mechanism. The second one depends on the drug reaction with π-acceptor reagent like DDQ in non-aqueous media via formation of charge transfer complex. These reactions were studied under various conditions and the optimum parameters were selected. Under proper conditions the suggested procedures were successfully applied for micro-determination of pseudoephedrine in pure and in Sinofree Tablets without interference from excepients. The values of SD, RSD, recovery %, LOD, LOQ and Sandell sensitivity refer to the high accuracy and precession of the applied procedures. The results obtained were compared with the data obtained by an official method, referring to confidence and agreement with DDQ procedure results; but it referred to the more accuracy of the molybdate data. Therefore, the suggested procedures are now successfully being applied in routine analysis of this drug in its pharmaceutical formulation (Sinofree) in Saudi Arabian Pharmaceutical Company (SPIMACO) in Boridah El-Qaseem, Saudi Arabia instead of imported kits had been previously used. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers.

    PubMed

    Sanjay, Sharma T; Dou, Maowei; Sun, Jianjun; Li, XiuJun

    2016-07-26

    Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.

  10. A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers

    PubMed Central

    Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, XiuJun

    2016-01-01

    Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings. PMID:27456979

  11. A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers

    NASA Astrophysics Data System (ADS)

    Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, Xiujun

    2016-07-01

    Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.

  12. Abbott Physicochemical Tiering (APT)--a unified approach to HTS triage.

    PubMed

    Cox, Philip B; Gregg, Robert J; Vasudevan, Anil

    2012-07-15

    The selection of the highest quality chemical matter from high throughput screening (HTS) is the ultimate aim of any triage process. Typically there are many hundreds or thousands of hits capable of modulating a given biological target in HTS with a wide range of physicochemical properties that should be taken into consideration during triage. Given the multitude of physicochemical properties that define drug-like space, a system needs to be in place that allows for a rapid selection of chemical matter based on a prioritized range of these properties. With this goal in mind, we have developed a tool, coined Abbott Physicochemical Tiering (APT) that enables hit prioritization based on ranges of these important physicochemical properties. This tool is now used routinely at Abbott to help prioritize hits out of HTS during the triage process. Herein we describe how this tool was developed and validated using Abbott internal high throughput ADME data (HT-ADME). Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Evaluation of the Abbott ARCHITECT Toxo IgM assay.

    PubMed

    Sickinger, Eva; Braun, Hans-Bertram; Praast, Gerald; Stieler, Myriam; Gundlach, Cordelia; Birkenbach, Claudia; Prostko, John; Palafox, Mary Ann; Frias, Edwin; Hsu, Stephen; Matias, Matthew; Pucci, Dominick; Hausmann, Michael; Sagel, Ulrich; Smith, Darwin

    2009-07-01

    Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays.

  14. Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA.

    PubMed

    Schutten, M; Peters, D; Back, N K T; Beld, M; Beuselinck, K; Foulongne, V; Geretti, A-M; Pandiani, L; Tiemann, C; Niesters, H G M

    2007-06-01

    The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS TaqMan assays. Two different protocols used during the testing period with and without a pre-m1000 RNA isolation spin were compared. The difference proved to be nonsignificant. A uracil-N-glycosylase (UNG) contamination control option in the HCV test for previous Roche COBAS Amplicor users was evaluated. It proved to decrease amplicon carryover by 100-fold independent of the amplicon input concentration. The protocol including UNG proved to overcome problems with false-positive negative controls. Comparison with other assays revealed only minor differences. The largest difference was observed between the Abbott HCV RealTime assay and the Roche COBAS Amplicor HCV Monitor version 2.0 assay.

  15. Improved amplification results following episodes of failure to amplify at the Amelogenin Locus using PowerPlex® ESI 16 Fast System.

    PubMed

    Berlyne, Sigal; Oz, Carla; Einot, Naftaly; Avraham, Shlomit; Ram, Tanya; Goldberg, Miri D; Gafny, Ron

    2017-07-01

    In 2012 the Israel Police DNA Casework laboratory adopted the 16 STR PowerPlex ® ESI kit for routine use. The Promega Company updated this kit and developed the PowerPlex ® ESI 16 Fast System in which all autosomal primer pairs remained identical to the original set, except at the amelogenin site. The master mix was improved and optimized which allowed for direct, faster and more robust amplification. Prior to implementing the PowerPlex ® ESI 16 Fast System in our lab, we conducted a preliminary assay where 213 casework samples were amplified using the new kit. These samples had previously been extracted by one of two extraction kits employed by our lab. (the PrepFiler ExpressTM and PrepFiler BTATM Forensic DNA Extraction Kits). The amplification results from these samples were compared to samples amplified using the original PowerPlex ® ESI 16 kit. Multiple incidents of failure to amplify at the amelogenin locus were noted using the new system with the recommended protocol at a rate of 13% (28 of 213 samples). Experiments were performed to understand whether these amplification failures could be a result of primer binding site mutations, extraction method reagents and/or inhibitors. The conclusions reached following these experiments, in conjunction with consultation with the manufacturer, led to the trial of a modified amplification protocol where the suggested annealing temperature was reduced by 2 degrees. To evaluate the efficiency of this altered protocol, a comparison study was undertaken where 88 additional casework samples were chosen and amplified using both the modified 58°C and the recommended 60°C annealing temperatures. We concluded that the most effective method in our laboratory for achieving a consistent and balanced amplification at the amelogenin locus was to reduce the annealing temperature from the manufacturer's recommended 60°C to 58°C. This modification resulted in a reduction of the failure to amplify at the amelogenin locus from 13% (28/213) to 1.1% (1/88) without any observed changes to the autosomal STR amplification results. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece

    PubMed Central

    2011-01-01

    Background HIV-1 is characterized by increased genetic heterogeneity which tends to hinder the reliability of detection and accuracy of HIV-1 RNA quantitation assays. Methods In this study, the Abbott RealTime HIV-1 (Abbott RealTime) assay was compared to the Roche Cobas TaqMan HIV-1 (Cobas TaqMan) and the Siemens Versant HIV-1 RNA 3.0 (bDNA 3.0) assays, using clinical samples of various viral load levels and subtypes from Greece, where the recent epidemiology of HIV-1 infection has been characterized by increasing genetic diversity and a marked increase in subtype A genetic strains among newly diagnosed infections. Results A high correlation was observed between the quantitative results obtained by the Abbott RealTime and the Cobas TaqMan assays. Viral load values quantified by the Abbott RealTime were on average lower than those obtained by the Cobas TaqMan, with a mean (SD) difference of -0.206 (0.298) log10 copies/ml. The mean differences according to HIV-1 subtypes between the two techniques for samples of subtype A, B, and non-A/non-B were 0.089, -0.262, and -0.298 log10 copies/ml, respectively. Overall, differences were less than 0.5 log10 for 85% of the samples, and >1 log10 in only one subtype B sample. Similarly, Abbott RealTime and bDNA 3.0 assays yielded a very good correlation of quantitative results, whereas viral load values assessed by the Abbott RealTime were on average higher (mean (SD) difference: 0.160 (0.287) log10 copies/ml). The mean differences according to HIV-1 subtypes between the two techniques for subtype A, B and non-A/non-B samples were 0.438, 0.105 and 0.191 log10 copies/ml, respectively. Overall, the majority of samples (86%) differed by less than 0.5 log10, while none of the samples showed a deviation of more than 1.0 log10. Conclusions In an area of changing HIV-1 subtype pattern, the Abbott RealTime assay showed a high correlation and good agreement of results when compared both to the Cobas TaqMan and bDNA 3.0 assays, for all HIV-1 subtypes tested. All three assays could determine viral load from samples of different HIV-1 subtypes adequately. However, assay variation should be taken into account when viral load monitoring of the same individual is assessed by different systems. PMID:21219667

  17. Assay of anti-HBs antibodies using a recombinant antigen and latex particle counting: comparison with five commercial tests.

    PubMed

    Galanti, L M; Cornu, C; Masson, P L; Robert, A R; Becheanu, D; Lamy, M E; Cambiaso, C L

    1991-05-01

    An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.

  18. Biomarkers for liver fibrosis

    DOEpatents

    Jacobs, Jon M.; Burnum-Johnson, Kristin E.; Baker, Erin M.; Smith, Richard D.; Gritsenko, Marina A.; Orton, Daniel

    2017-05-16

    Methods and systems for diagnosing or prognosing liver fibrosis in a subject are provided. In some examples, such methods and systems can include detecting liver fibrosis-related molecules in a sample obtained from the subject, comparing expression of the molecules in the sample to controls representing expression values expected in a subject who does not have liver fibrosis or who has non-progressing fibrosis, and diagnosing or prognosing liver fibrosis in the subject when differential expression of the molecules between the sample and the controls is detected. Kits for the diagnosis or prognosis of liver fibrosis in a subject are also provided which include reagents for detecting liver fibrosis related molecules.

  19. Biomarkers for liver fibrosis

    DOEpatents

    Jacobs, Jon M.; Burnum-Johnson, Kristin E.; Baker, Erin M.; Smith, Richard D.; Gritsenko, Marina A.; Orton, Daniel

    2015-09-15

    Methods and systems for diagnosing or prognosing liver fibrosis in a subject are provided. In some examples, such methods and systems can include detecting liver fibrosis-related molecules in a sample obtained from the subject, comparing expression of the molecules in the sample to controls representing expression values expected in a subject who does not have liver fibrosis or who has non-progressing fibrosis, and diagnosing or prognosing liver fibrosis in the subject when differential expression of the molecules between the sample and the controls is detected. Kits for the diagnosis or prognosis of liver fibrosis in a subject are also provided which include reagents for detecting liver fibrosis related molecules.

  20. Probes for anionic cell surface detection

    DOEpatents

    Smith, Bradley D.

    2013-03-05

    Embodiments of the present invention are generally directed to compositions comprising a class of molecular probes for detecting the presence of anionic cell surfaces. Embodiments include compositions that are enriched for these compositions and preparations, particularly preparations suitable for use as laboratory/clinical reagents and diagnostic indicators, either alone or as part of a kit. An embodiment of the invention provides for a highly selective agent useful in the discernment and identification of dead or dying cells, such as apoptotic cells, in a relatively calcium-free environment. An embodiment of the invention provides a selective agent for the identification of bacteria in a mixed population of bacterial cells and nonbacterial cells.

  1. First two-reagent vitamin D assay for general clinical chemistry.

    PubMed

    Saida, Fakhri B; Padilla-Chee, Mario; Dou, Chao; Yuan, Chong

    2018-05-01

    Vitamin D is a lipid-soluble molecule that plays key physiological roles in the metabolism of calcium, phosphate and magnesium. Recent studies show that deficiency in vitamin D is linked to cardiovascular diseases, autoimmune diseases and cancer. As a result, regular monitoring of 25-OH vitamin D (the main circulating form of vitamin D) is becoming essential. Current 25-OH vitamin D testing methodologies are cumbersome (too many reagents, long incubation times, phase separation) and are not compatible with general clinical chemistry platforms. Here, we report on a novel method to detect 25-OH vitamin D that is fast (results in 10 min or less), simple (two reagents) and compatible with virtually all general clinical chemistry analyzers. An immunoturbidimetric assay for 25-OH vitamin D (the Diazyme EZ Vitamin D Assay) has been developed using nanoparticles and vitamin D-specific antibodies. The performance of the assay kit, which consists of two reagents and five calibrators, was tested on the Beckman AU680 analyzer (AU680). The new assay was precise, sensitive (LOD = 7.2 nmol/L), linear (up to 390.1 nmol/L) and correlated strongly (R 2  > 0.95) with major commercial 25-OH vitamin D assays. Additionally, the assay was found to be the fastest to date, with the first results obtained within 10 min. Throughput on the AU680 was estimated at over 300 tests per hour. The newly developed 25-OH vitamin D assay is fast, precise and accurate. It can be run on most general chemistry analyzers. This assay aims at providing vitamin D-testing capabilities to all clinical chemistry laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Chromosome-specific staining to detect genetic rearrangements associated with chromosome 3 and/or chromosome 17

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Kallioniemi, Olli-Pekka; Kallioniemi, Anne; Sakamoto, Masaru

    2009-10-06

    Methods and compositions for staining based upon nucleic acid sequence that employ nudeic nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML), retinoblastoma, ovarian and uterine cancers, and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goudeau, Danielle; Nath, Nandita; Ciobanu, Doina

    Our approach to prokaryotic single-cell Whole Genome Amplification at the JGI continues to evolve. To increase both the quality and number of single-cell genomes produced, we explore all aspects of the process from cell sorting to sequencing. For example, we now utilize specialized reagents, acoustic liquid handling, and reduced reaction volumes eliminate non-target DNA contamination in WGA reactions. More specifically, we use a cleaner commercial WGA kit from Qiagen that employs a UV decontamination procedure initially developed at the JGI, and we use the Labcyte Echo for tip-less liquid transfer to set up 2uL reactions. Acoustic liquid handling also dramaticallymore » reduces reagent costs. In addition, we are exploring new cell lysis methods including treatment with Proteinase K, lysozyme, and other detergents, in order to complement standard alkaline lysis and allow for more efficient disruption of a wider range of cells. Incomplete lysis represents a major hurdle for WGA on some environmental samples, especially rhizosphere, peatland, and other soils. Finding effective lysis strategies that are also compatible with WGA is challenging, and we are currently assessing the impact of various strategies on genome recovery.« less

  4. The Labour Process of Teaching at John Abbott College (Part One).

    ERIC Educational Resources Information Center

    Johnson, Walter

    This survey was conducted at John Abbott College to gauge teachers' responses to issues concerning their job satisfaction, interaction with colleagues, perceptions of student abilities, and perceptions concerning union negotiating priorities and areas of conflict within the institutional environment. Of the 75 teachers contacted, 47 returned…

  5. The Instructional Guide for Abbott Skills Enhancement Classes. Revised Edition.

    ERIC Educational Resources Information Center

    Ballinger, Ronda; Gee, Mary Kay

    This guide, which integrates adult basic education (ABE) curriculum, job skills for Abbott Laboratories, and work-related foundation skills, is designed for an instructional program in the skill areas of reading, writing, oral communications, mathematics, and problem solving. In addition to creating a uniform process and product to promote…

  6. Tobago Prostate Survey: Prostate Cancer Risk in a Large Population-Based Study of Men of African Descent

    DTIC Science & Technology

    2001-06-01

    Pittsburgh Central Pathology Laboratory using the automated Microparticle Enzyme Immunoassay, Abbot AxSYM PSA assay (Abbott Laboratories, Abbott Park, IL, USA...1997) pesticide applicators in Sweden (Dich & Wik/und, 1998) "* No evidence of an association (Giovannuccietal., 1997; * Increased risk for soap

  7. 75 FR 80061 - Abbott Laboratories, Inc.; Withdrawal of Approval of a New Drug Application for MERIDIA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-21

    ... withdrawing approval of a new drug application (NDA) for MERIDIA (sibutramine hydrochloride (HCl)) oral... requested that Abbott voluntarily withdraw MERIDIA (sibutramine HCl) oral capsules from the market, based on FDA's recent analysis of clinical trial data from the Sibutramine Cardiovascular Outcomes Trial (SCOUT...

  8. Genetically altered mice for evaluation of mode-of-action (MOA)

    EPA Science Inventory

    Genetically altered mice for evaluation of mode-of-action (MOA). Barbara D. Abbott, Cynthia J. Wolf, Kaberi P. Das, Christopher S. Lau. (Presented by B. Abbott). This presentation provides an example of the use of genetically modified mice to determine the mode-of-action of r...

  9. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen artus HBV RG kit.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-10-01

    Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. [Contribution of HCV core antigen testing in HCV diagnosis by test from the company Abbott Laboratories].

    PubMed

    Trbusek, J

    2009-11-01

    Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.

  11. Engaging Parents, Families and the Community to Improve Student Achievement. Abbott Implementation Resource Guide

    ERIC Educational Resources Information Center

    Henderson, Anne

    2004-01-01

    During the summer of 2003, a statewide committee of representative educational stakeholders on "cooperative rulemaking" was convened jointly by the Department of Education and the Education Law Center. The Supreme Court in "Abbott X" had directed the establishment of this committee to develop new regulations more consistent…

  12. [Analytical performances of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine].

    PubMed

    De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie

    2016-01-01

    Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.

  13. Comparison of Two Commercial Automated Nucleic Acid Extraction and Integrated Quantitation Real-Time PCR Platforms for the Detection of Cytomegalovirus in Plasma

    PubMed Central

    Tsai, Huey-Pin; Tsai, You-Yuan; Lin, I-Ting; Kuo, Pin-Hwa; Chen, Tsai-Yun; Chang, Kung-Chao; Wang, Jen-Ren

    2016-01-01

    Quantitation of cytomegalovirus (CMV) viral load in the transplant patients has become a standard practice for monitoring the response to antiviral therapy. The cut-off values of CMV viral load assays for preemptive therapy are different due to the various assay designs employed. To establish a sensitive and reliable diagnostic assay for preemptive therapy of CMV infection, two commercial automated platforms including m2000sp extraction system integrated the Abbott RealTime (m2000rt) and the Roche COBAS AmpliPrep for extraction integrated COBAS Taqman (CAP/CTM) were evaluated using WHO international CMV standards and 110 plasma specimens from transplant patients. The performance characteristics, correlation, and workflow of the two platforms were investigated. The Abbott RealTime assay correlated well with the Roche CAP/CTM assay (R2 = 0.9379, P<0.01). The Abbott RealTime assay exhibited higher sensitivity for the detection of CMV viral load, and viral load values measured with Abbott RealTime assay were on average 0.76 log10 IU/mL higher than those measured with the Roche CAP/CTM assay (P<0.0001). Workflow analysis on a small batch size at one time, using the Roche CAP/CTM platform had a shorter hands-on time than the Abbott RealTime platform. In conclusion, these two assays can provide reliable data for different purpose in a clinical virology laboratory setting. PMID:27494707

  14. Comparison of DRY and WET vaginal swabs with cervical specimens in Roche Cobas 4800 HPV and Abbott RealTime High Risk HPV tests.

    PubMed

    Jun, Jae Kwan; Lim, Myong Cheol; Hwang, Sang-Hyun; Shin, Hye Young; Hwang, Na Rae; Kim, Yeon-Jin; Yoo, Chong Woo; Lee, Dong Ock; Joo, Jungnam; Park, Sang-Yoon; Lee, Do-Hoon

    2016-06-01

    Self-collected vaginal swab samples have been proposed as an alternative specimen collection method for human papillomavirus (HPV) DNA detection. Two vaginal swabs (a cone-shaped flocked swab (DRY) and a L-shape FLOQSwab with 2mL eNAT transport medium (WET)) were compared to standard cervical samples for HPV DNA testing. Additionally, they were also compared by using Roche Cobas 4800 HPV (Roche_HPV) and Abbott Real-time High Risk HPV (Abbott_HPV) tests. Ninety-six women were prospectively enrolled from the National Cancer Center in Korea between June and August 2015. WET and DRY vaginal swabs and cervical specimens were collected. Roche_HPV and Abbott_HPV tests were performed. The Roche_HPV test on cervical specimens was used as reference. The observed agreements (kappa) of Roche_HPV and Abbott_HPV between WET and DRY swabs were 89.6% (0.790, 95% confidence interval (95% CI): 0.667-0.913) and 91.7% (0.833, 95%CI: 0.723-0.943), respectively. No statistical difference was observed between WET and DRY swabs (p>0.05 for all comparisons). For HPV16/18, the sensitivity/specificity of Roche_HPV on the DRY and WET samples presented 93.8%/96.3% and 87.5%/97.5%, respectively. For other High Risk HPV (hrHPV), the sensitivity/specificity of Roche_HPV on the DRY and WET swabs presented 91.9%/91.5% and 97.3%/98.3, respectively. The sensitivity/specificity of the Abbott_HPV on the DRY and WET swabs were 93.8%/98.8%, 87.5%/98.8% for HPV16/18, and 91.9%/93.2%, 100.0%/93.2% for other hrHPV, respectively. HPV tests performed similarly when using vaginal DRY and WET swab samples. Using DRY and WET swabs to collect vaginal specimens could be an alternative to collecting cervical samples for HPV DNA testing. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Multisite analytical evaluation of the Abbott ARCHITECT cyclosporine assay.

    PubMed

    Wallemacq, Pierre; Maine, Gregory T; Berg, Keith; Rosiere, Thomas; Marquet, Pierre; Aimo, Giuseppe; Mengozzi, Giulio; Young, Julianna; Wonigeit, Kurt; Kretschmer, Robert; Wermuth, Bendicht; Schmid, Rainer W

    2010-04-01

    The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated immunoassay with magnetic microparticles coated with anti-CsA antibody and an acridinium-CsA tracer. Imprecision testing at the 7 evaluation sites gave a range of total % coefficient of variations of 7.5%-12.2% at 87.5 ng/mL, 6.6%-14.3% at 411 ng/mL, and 5.2%-10.7% at 916 ng/mL. The lower limit of quantification ranged from 12 to 20 ng/mL. Purified CsA metabolites AM1, AM1c, AM4N, AM9, and AM19 were tested in whole blood by the ARCHITECT assay and showed minimal cross-reactivity at all 7 sites. In particular, AM1 and AM9 cross-reactivity in the ARCHITECT assay, ranged from -2.5% to 0.2% and -0.8% to 2.2%, respectively, and was significantly lower than for the TDx assay, in which the values were 3.2% and 16.1%, respectively. Comparable testing of metabolites in the Dade Dimension Xpand assay at 2 evaluation sites showed cross-reactivity to AM4N (6.4% and 6.8%) and AM9 (2.6% and 3.6%) and testing on the Roche Integra 800 showed cross-reactivity to AM1c (2.4%), AM9 (10.7%), and AM19 (2.8%). Cyclosporine International Proficiency Testing Scheme samples, consisting of both pooled specimens from patients receiving CsA therapy as well as whole-blood specimens supplemented with CsA, were tested by the ARCHITECT assay at 6 sites and showed an average bias of -24 to -58 ng/mL versus LC/MSMS CsA and -2 to -37 ng/mL versus AxSYM CsA. Studies were performed with the ARCHITECT CsA assay on patient specimens with the following results: ARCHITECT CsA assay versus LC/MSMS, average bias of 31 ng/mL; ARCHITECT versus the Dade Dimension assay (4 sites), average biases of -7 to -228 ng/mL; ARCHITECT versus AxSYM and TDx, average biases of -4 and -53 ng/mL, respectively. Spearman correlation coefficients were >or=0.89. The ARCHITECT CsA assay has significantly reduced CsA metabolite interference relative to other immunoassays and is a convenient and sensitive semiautomated method to measure CsA in whole blood.

  16. Early Childhood Education: The Sustainability of the Benefits of Preschool Participation in Abbott Districts

    ERIC Educational Resources Information Center

    Fernandez, Norma

    2010-01-01

    The landmark New Jersey Supreme Court school funding case, "Abbott v. Burke", established the availability of preschool for all three- and four-year-olds living within the state's thirty-one poorest districts as a means of eradicating the effects of poverty. Longitudinal studies have shown the value of high quality preschool programs for…

  17. Decentralization and Participatory Decision-Making: Implementing School-Based Management in the Abbott Districts.

    ERIC Educational Resources Information Center

    Walker, Elaine M.

    2000-01-01

    This study examined issues faced during implementation of school-based management (SBM) in New Jersey's special needs or Abbott districts, using a literature review, surveys of K-12 schools, and focus groups with central office administrators. The study examined forms of SBM, team operations, local autonomy versus state power, skills required to…

  18. Comparing viral metagenomics methods using a highly multiplexed human viral pathogens reagent

    PubMed Central

    Li, Linlin; Deng, Xutao; Mee, Edward T.; Collot-Teixeira, Sophie; Anderson, Rob; Schepelmann, Silke; Minor, Philip D.; Delwart, Eric

    2014-01-01

    Unbiased metagenomic sequencing holds significant potential as a diagnostic tool for the simultaneous detection of any previously genetically described viral nucleic acids in clinical samples. Viral genome sequences can also inform on likely phenotypes including drug susceptibility or neutralization serotypes. In this study, different variables of the laboratory methods often used to generate viral metagenomics libraries on the efficiency of viral detection and virus genome coverage were compared. A biological reagent consisting of 25 different human RNA and DNA viral pathogens was used to estimate the effect of filtration and nuclease digestion, DNA/RNA extraction methods, pre-amplification and the use of different library preparation kits on the detection of viral nucleic acids. Filtration and nuclease treatment led to slight decreases in the percentage of viral sequence reads and number of viruses detected. For nucleic acid extractions silica spin columns improved viral sequence recovery relative to magnetic beads and Trizol extraction. Pre-amplification using random RT-PCR while generating more viral sequence reads resulted in detection of fewer viruses, more overlapping sequences, and lower genome coverage. The ScriptSeq library preparation method retrieved more viruses and a greater fraction of their genomes than the TruSeq and Nextera methods. Viral metagenomics sequencing was able to simultaneously detect up to 22 different viruses in the biological reagent analyzed including all those detected by qPCR. Further optimization will be required for the detection of viruses in biologically more complex samples such as tissues, blood, or feces. PMID:25497414

  19. Biomedical support systems. [use and verification of biomedical hardware in altitude test

    NASA Technical Reports Server (NTRS)

    Brockett, R. M.; Ferguson, J. M.; Luczkowski, S. M.

    1973-01-01

    Biomedical support hardware for SMEAT consisted basically of two systems, the inflight medical support system, and the operational bioinstrumentation system. The former is essentially a diagnostic and therapeutic kit; the latter is a belt equipped with sensors worn by the crewman to permit monitoring of his vital signs. Special attention was given during to the use and verification of the items in the systems so that changes required in the equipment could be pinpointed and effected prior to the Skylab mission. During the in-chamber testing, evaluations were made of the effectiveness of the proposed microbiology procedures, techniques, equipment, and the stability of media and reagents over the extended period of storage.

  20. Breaking Ground: Rebuilding New Jersey's Urban Schools. The Abbott School Construction Program

    ERIC Educational Resources Information Center

    Ponessa, Joan

    2004-01-01

    This report presents a brief history of the Abbott School Construction Program, describes the implementation to date, lays out some current challenges, and outlines lessons learned from the process so far--what is known now about how such an initiative should be planned and carried out. The report is intended to illuminate the complex process of…

  1. Avoidance of generic competition by Abbott Laboratories' fenofibrate franchise.

    PubMed

    Downing, Nicholas S; Ross, Joseph S; Jackevicius, Cynthia A; Krumholz, Harlan M

    2012-05-14

    The ongoing debate concerning the efficacy of fenofibrate has overshadowed an important aspect of the drug's history: Abbott Laboratories, the maker of branded fenofibrate, has produced several bioequivalent reformulations that dominate the market, although generic fenofibrate has been available for almost a decade. This continued use of branded formulations, which cost twice as much as generic versions of fenofibrate, imposes an annual cost of approximately $700 million on the US health care system. Abbott Laboratories maintained its dominance of the fenofibrate market in part through a complex switching strategy involving the sequential launch of branded reformulations that had not been shown to be superior to the first-generation product and patent litigation that delayed the approval of generic formulations. The small differences in dose of the newer branded formulations prevented their substitution with generics of older-generation products. As soon as direct generic competition seemed likely at the new dose level, where substitution would be allowed, Abbott would launch another reformulation, and the cycle would repeat. Based on the fenofibrate example, our objective is to describe how current policy can allow pharmaceutical companies to maintain market share using reformulations of branded medications, without demonstrating the superiority of next-generation products.

  2. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    PubMed

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  3. Methods of biological dosimetry employing chromosome-specific staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    2000-01-01

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Further, methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. Still further, the invention provides for automated means to detect and analyse chromosomal abnormalities.

  4. Methods And Compositions For Chromosome-Specific Staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    2003-08-19

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Further, methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. Still further, the invention provides for automated means to detect and analyse chromosomal abnormalities.

  5. Compositions for chromosome-specific staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    1998-01-01

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Further, methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. Still further, the invention provides for automated means to detect and analyse chromosomal abnormalities.

  6. Compositions for chromosome-specific staining

    DOEpatents

    Gray, J.W.; Pinkel, D.

    1998-05-26

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. The methods produce staining patterns that can be tailored for specific cytogenetic analyses. The probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. The invention provides for automated means to detect and analyze chromosomal abnormalities. 17 figs.

  7. Archeological Testing Fort Hood: 1994-1995. Volume 2

    DTIC Science & Technology

    1996-10-01

    Type 3 sediment appears to be dry present, both as discrete lenses which are usually decomposition, which renders it a loose, grayish readily...degrading the quality of the shelters, rendering them increasingly attractive for resource. habitation. However, as noted previously (Abbott 1994; Abbott...651 characteristic renders them subject to additional federal laws (e.g., NAGPRA), it increases the urgency to implement management policies that will

  8. Comparison of Perceptions of "Preparedness" of John Abbott C.E.G.E.P. Nursing Graduates: Prior to Graduation and After.

    ERIC Educational Resources Information Center

    Iton, Carmen; Sabiston, Judy

    A study of John Abbott College's nursing graduates was conducted to determine how well prepared for their professional responsibilities the graduates saw themselves just prior to graduation and later after working in the nursing field. A sample of 98 nursing students who graduated between 1986 and 1988 was surveyed, with 93% responding to the…

  9. Verification of the harmonization of human epididymis protein 4 assays.

    PubMed

    Ferraro, Simona; Borille, Simona; Carnevale, Assunta; Frusciante, Erika; Bassani, Niccolò; Panteghini, Mauro

    2016-10-01

    Serum human epididymis protein 4 (HE4) has gained relevance as an ovarian cancer (OC) biomarker and new automated methods have replaced the first released manual EIA by tracing results to it. We verified agreement and bias of automated methods vs. EIA as well as possible effects on patients' management. One hundred and fifteen serum samples were measured by Abbott Architect i2000, Fujirebio Lumipulse G1200, Roche Modular E170, and Fujirebio EIA. Passing-Bablok regression was used to compare automated assays to EIA and agreement between methods was estimated by Lin's concordance correlation coefficient (CCC). The bias vs. EIA was estimated and compared to specifications derived from HE4 biological variation. Median (25th-75th percentiles) HE4 concentrations (pmol/L) were 84.5 (60.1-148.8) for EIA, 82.7 (50.3-153.9) for Abbott, 89.1 (55.2-154.9) for Roche, and 112.2 (67.8-194.2) for Fujirebio. Estimated regressions and agreements (95% confidence interval) were: Abbott=1.01(0.98-1.03) EIA-4.8(-7.5/-2.6), CCC=0.99(0.99-1.00); Roche=0.91(0.89-0.93) EIA+5.7(4.2/8.0), CCC=0.98(0.98-0.99); Fujirebio=1.20(1.17-1.24) EIA+ 2.4(-0.6/4.9), CCC=0.97(0.96-0.98). The average bias vs. EIA resulted within the desirable goal for Abbott [-3.3% (-6.1/-0.5)] and Roche [-0.2% (-3.0/2.5)]. However, while for Abbott the bias was constant and acceptable along the measurement concentration range, Roche bias increased up to -28% for HE4 values >250 pmol/L. Lumipulse showed a markedly positive bias [25.3% (21.8/28.8)]. Abbott and Roche assays exhibited a good comparability in the range of HE4 values around the previously recommended 140 pmol/L cut-off. For patient monitoring, however, the assay used for determining serial HE4 must not be changed as results from different systems in lower and higher concentration ranges can markedly differ.

  10. A New ELISA Using the ANANAS Technology Showing High Sensitivity to diagnose the Bovine Rhinotracheitis from Individual Sera to Pooled Milk.

    PubMed

    Casarin, Elisabetta; Lucchese, Laura; Grazioli, Santina; Facchin, Sonia; Realdon, Nicola; Brocchi, Emiliana; Morpurgo, Margherita; Nardelli, Stefano

    2016-01-01

    Diagnostic tests for veterinary surveillance programs should be efficient, easy to use and, possibly, economical. In this context, classic Enzyme linked ImmunoSorbent Assay (ELISA) remains the most common analytical platform employed for serological analyses. The analysis of pooled samples instead of individual ones is a common procedure that permits to certify, with one single test, entire herds as "disease-free". However, diagnostic tests for pooled samples need to be particularly sensitive, especially when the levels of disease markers are low, as in the case of anti-BoHV1 antibodies in milk as markers of Infectious Bovine Rhinotracheitis (IBR) disease. The avidin-nucleic-acid-nanoassembly (ANANAS) is a novel kind of signal amplification platform for immunodiagnostics based on colloidal poly-avidin nanoparticles that, using model analytes, was shown to strongly increase ELISA test performance as compared to monomeric avidin. Here, for the first time, we applied the ANANAS reagent integration in a real diagnostic context. The monoclonal 1G10 anti-bovine IgG1 antibody was biotinylated and integrated with the ANANAS reagents for indirect IBR diagnosis from pooled milk mimicking tank samples from herds with IBR prevalence between 1 to 8%. The sensitivity and specificity of the ANANAS integrated method was compared to that of a classic test based on the same 1G10 antibody directly linked to horseradish peroxidase, and a commercial IDEXX kit recently introduced in the market. ANANAS integration increased by 5-fold the sensitivity of the 1G10 mAb-based conventional ELISA without loosing specificity. When compared to the commercial kit, the 1G10-ANANAS integrated method was capable to detect the presence of anti-BHV1 antibodies from bulk milk of gE antibody positive animals with 2-fold higher sensitivity and similar specificity. The results demonstrate the potentials of this new amplification technology, which permits improving current classic ELISA sensitivity limits without the need for new hardware investments.

  11. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    PubMed

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  12. CLSI-based transference of CALIPER pediatric reference intervals to Beckman Coulter AU biochemical assays.

    PubMed

    Abou El Hassan, Mohamed; Stoianov, Alexandra; Araújo, Petra A T; Sadeghieh, Tara; Chan, Man Khun; Chen, Yunqi; Randell, Edward; Nieuwesteeg, Michelle; Adeli, Khosrow

    2015-11-01

    The CALIPER program has established a comprehensive database of pediatric reference intervals using largely the Abbott ARCHITECT biochemical assays. To expand clinical application of CALIPER reference standards, the present study is aimed at transferring CALIPER reference intervals from the Abbott ARCHITECT to Beckman Coulter AU assays. Transference of CALIPER reference intervals was performed based on the CLSI guidelines C28-A3 and EP9-A2. The new reference intervals were directly verified using up to 100 reference samples from the healthy CALIPER cohort. We found a strong correlation between Abbott ARCHITECT and Beckman Coulter AU biochemical assays, allowing the transference of the vast majority (94%; 30 out of 32 assays) of CALIPER reference intervals previously established using Abbott assays. Transferred reference intervals were, in general, similar to previously published CALIPER reference intervals, with some exceptions. Most of the transferred reference intervals were sex-specific and were verified using healthy reference samples from the CALIPER biobank based on CLSI criteria. It is important to note that the comparisons performed between the Abbott and Beckman Coulter assays make no assumptions as to assay accuracy or which system is more correct/accurate. The majority of CALIPER reference intervals were transferrable to Beckman Coulter AU assays, allowing the establishment of a new database of pediatric reference intervals. This further expands the utility of the CALIPER database to clinical laboratories using the AU assays; however, each laboratory should validate these intervals for their analytical platform and local population as recommended by the CLSI. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Comparison of the Gen-Probe Aptima HIV-1 and Abbott HIV-1 qualitative assays with the Roche Amplicor HIV-1 DNA assay for early infant diagnosis using dried blood spots.

    PubMed

    Nelson, Julie A E; Hawkins, J Tyler; Schanz, Maria; Mollan, Katie; Miller, Melissa B; Schmitz, John L; Fiscus, Susan A

    2014-08-01

    The current gold standard for infant diagnosis of HIV-1 is the Roche Amplicor Qualitative DNA assay, but it is being phased out. Compare the Abbott qualitative assay and the Gen-Probe Aptima assay to the gold standard Roche DNA assay using dried blood spots (DBS). The Gen-Probe Aptima and Abbott qualitative HIV-1 assays were compared to the Roche DNA assay for early infant diagnosis. Specificity and sensitivity were determined for the three assays using DBS from 50 HIV-exposed uninfected infants and 269 HIV-1 infected adults from North Carolina, respectively. All of the negative and 151 of the positive DBS had valid results on the 3 different assays, and an additional 118 positive DBS had valid results on the Roche DNA and Aptima assays. All three assays were very specific. The Roche DNA assay was the most sensitive (96.7%) over a wide range of HIV PVL, including samples with PVL<400 copies/ml. Restricted to samples with PVL>400 copies/ml, the Gen-Probe Aptima assay had sensitivity (96.5%) comparable to the Roche DNA assay (98.8%). The Abbott Qualitative assay was the least sensitive and only had sensitivity above 95% among samples with PVL over 1000 copies/ml. The Abbott HIV-1 Qualitative assay was not as sensitive as the comparator assays, so it would not be a useful replacement assay, especially for infants taking antiretroviral prophylaxis. The Gen-Probe Aptima assay is an adequate replacement option for infant diagnosis using DBS. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Population-based pediatric reference intervals for general clinical chemistry analytes on the Abbott Architect ci8200 instrument.

    PubMed

    Ridefelt, Peter; Aldrimer, Mattias; Rödöö, Per-Olof; Niklasson, Frank; Jansson, Leif; Gustafsson, Jan; Hellberg, Dan

    2012-02-29

    Reference intervals are crucial decision-making tools aiding clinicians in differentiating between healthy and diseased populations. However, for children such values often are lacking or incomplete. Blood samples were obtained from 692 healthy children, aged 6 months to 18 years, recruited in daycare centers and schools. Twelve common general clinical chemistry analytes were measured on the Abbott Architect ci8200 platform; sodium, potassium, chloride, calcium, albumin-adjusted calcium, phosphate, magnesium, creatinine (Jaffe and enzymatic), cystatin C, urea and uric acid. Age- and gender specific pediatric reference intervals were defined by calculating the 2.5th and 97.5th percentiles. The data generated is primarily applicable to a Caucasian population when using the Abbott Architect platform, but could be used by any laboratory if validated for the local patient population.

  15. Liver Rapid Reference Set Application: Hemken - Abbott (2015) — EDRN Public Portal

    Cancer.gov

    The aim for this testing is to find a small panel of biomarkers (n=2-5) that can be tested on the Abbott ARCHITECT automated immunoassay platform for the early detection of hepatocellular carcinoma (HCC). This panel of biomarkers should perform significantly better than alpha-fetoprotein (AFP) alone based on multivariate statistical analysis. This testing of the EDRN reference set will help expedite the selection of a small panel of ARCHITECT biomarkers for the early detection of HCC. The panel of ARCHITECT biomarkers Abbott plans to test include: AFP, protein induced by vitamin K absence or antagonist-II (PIVKA-II), golgi protein 73 (GP73), hepatocellular growth factor (HGF), dipeptidyl peptidase 4 (DPP4) and DPP4/seprase (surface expressed protease) heterodimer hybrid. PIVKA-II is abnormal des-carboxylated prothrombin (DCP) present in vitamin K deficiency.

  16. Evaluation and structure-activity relationship analysis of a new series of arylnaphthalene lignans as potential anti-tumor agents.

    PubMed

    Luo, Jiaoyang; Hu, Yichen; Kong, Weijun; Yang, Meihua

    2014-01-01

    Arylnaphthalene lignan lactones have attracted considerable interest because of their anti-tumor and anti-hyperlipidimic activities. However, to our knowledge, few studies have explored the effects of these compounds on human leukemia cell lines. In this study, five arylnaphthalene lignans including 6'-hydroxy justicidin A (HJA), 6'-hydroxy justicidin B (HJB), justicidin B (JB), chinensinaphthol methyl ether (CME) and Taiwanin E methyl ether (TEME) were isolated from Justicia procumbens and their effects on the proliferation and apoptosis of the human leukemia K562 cell line were investigated then used to assess structure-activity relationships. To achieve these aims, cytotoxicity was assayed using the MTT assay, while intracellular SOD activity was detected using the SOD Activity Assay kit. Apoptosis was measured by both the using a cycle TEST PLUS DNA reagent kit as well as the FITC Annexin V apoptosis detection kit in combination with flow cytometry. Activation of caspase-mediated apoptosis was evaluated using a FITC active Caspase-3 apoptosis kit and flow cytometry. The results indicated that HJB, HJA and JB significantly inhibited the growth of K562 cells by decreasing both proliferation and SOD activity and inducing apoptosis. The sequence of anti-proliferative activity induced by the five tested arylnaphthalenes by decreasing strength was HJB > HJA > JB > CME > TEME. HJB, HJA and JB also decreased SOD activity and induced apoptosis in a dose-dependent manner. Activation of caspase-3 further indicated that HJB, HJA and JB induced caspase-dependent intrinsic and/or extrinsic apoptosis pathways. Together, these assays suggest that arylnaphthalene lignans derived from Justicia procumbens induce apoptosis to varying degrees, through a caspase-dependent pathway in human leukemia K562 cells. Furthermore, analysis of structure-activity relationships suggest that hydroxyl substitution at C-1 and C-6' significantly increased the antiproliferative activity of arylnaphthalene lignans while a methoxyl at C-1 significantly decreased the effect.

  17. Development of a Real-Time PCR Protocol Requiring Minimal Handling for Detection of Vancomycin-Resistant Enterococci with the Fully Automated BD Max System.

    PubMed

    Dalpke, Alexander H; Hofko, Marjeta; Zimmermann, Stefan

    2016-09-01

    Vancomycin-resistant enterococci (VRE) are an important cause of health care-associated infections, resulting in significant mortality and a significant economic burden in hospitals. Active surveillance for at-risk populations contributes to the prevention of infections with VRE. The availability of a combination of automation and molecular detection procedures for rapid screening would be beneficial. Here, we report on the development of a laboratory-developed PCR for detection of VRE which runs on the fully automated Becton Dickinson (BD) Max platform, which combines DNA extraction, PCR setup, and real-time PCR amplification. We evaluated two protocols: one using a liquid master mix and the other employing commercially ordered dry-down reagents. The BD Max VRE PCR was evaluated in two rounds with 86 and 61 rectal elution swab (eSwab) samples, and the results were compared to the culture results. The sensitivities of the different PCR formats were 84 to 100% for vanA and 83.7 to 100% for vanB; specificities were 96.8 to 100% for vanA and 81.8 to 97% for vanB The use of dry-down reagents and the ExK DNA-2 kit for extraction showed that the samples were less inhibited (3.3%) than they were by the use of the liquid master mix (14.8%). Adoption of a cutoff threshold cycle of 35 for discrimination of vanB-positive samples allowed an increase of specificity to 87.9%. The performance of the BD Max VRE assay equaled that of the BD GeneOhm VanR assay, which was run in parallel. The use of dry-down reagents simplifies the assay and omits any need to handle liquid PCR reagents. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  18. Uptake of DNA by cancer cells without a transfection reagent.

    PubMed

    Kong, Yanping; Zhang, Xianbo; Zhao, Yongliang; Xue, Yanfang; Zhang, Ye

    2017-01-21

    Cancer cells exhibit elevated levels of glucose uptake and may obtain pre-formed, diet-derived fatty acids from the bloodstream to boost their rapid growth; they may also use nucleic acid from their microenvironment. The study of processing nucleic acid by cancer cells will help improve the understanding of the metabolism of cancer. DNA is commonly packaged into a viral or lipid particle to be transferred into cells; this process is called transfection in laboratory. Cancer cells are known for having gene mutations and the evolving ability of endocytosis. Their uptake of DNAs might be different from normal cells; they may take in DNAs directly from the environment. In this report, we studied the uptake of DNAs in cancer cells without a transfection reagent. A group of DNA fragments were prepared with PCR and labeled with isotope phosphorous-32 to test their uptake by Huh 7 (liver cancer) and THLE3 (normal liver cells) after incubation overnight by counting radioactivity of the cells' genomic DNA. Multiple cell lines including breast cancer and lung cancer were tested with the same method. DNA molecules were also labeled with fluorescence to test the location in the cells using a kit of "label it fluorescence in situ hybridization (FISH)" from Mirus (USA). The data demonstrated that hepatocellular carcinoma cells possess the ability to take in large DNA fragments directly without a transfection reagent whereas normal liver cells cannot. Huh7 and MDA-MB231 cells displayed a significantly higher Rhodamine density in the cytoplasmic phagosomes and this suggests that the mechanism of uptake of large DNA by cancer cells is likely endocytosis. The efficacy of uptake is related to the DNA's size. Some cell lines of lung cancer and breast cancer also showed similar uptake of DNA. In the present study, we have revealed the evidence that some cancer cells, but not nontumorigenic cells, can take DNA fragments directly from the environment without the aid of the transfecting reagent.

  19. Performance evaluation of the Abbott RealTime HCV Genotype II for hepatitis C virus genotyping.

    PubMed

    Sohn, Yong-Hak; Ko, Sun-Young; Kim, Myeong Hee; Oh, Heung-Bum

    2010-04-01

    The Abbott RealTime hepatitis C virus (HCV) Genotype II (Abbott Molecular Inc.) for HCV genotyping, which uses real-time PCR technology, has recently been developed. Accuracy and sensitivity of detection were assessed using the HCV RNA PHW202 performance panel (SeraCare Life Sciences). Consistency with restriction fragment mass polymorphism (RFMP) data, cross-reactivity with other viruses, and the ability to detect minor strains in mixtures of genotypes 1 and 2 were evaluated using clinical samples. All performance panel viruses were correctly genotyped at levels of >500 IU/mL. Results were 100% concordant with RFMP genotypic data (66/66). However, 5% (3/66) of the samples examined displayed probable genotypic cross reactivity. No cross reactivity with other viruses was evident. Minor strains in the mixtures were not effectively distinguished, even at quantities higher than the detection limit. The Abbott RealTime HCV Genotype II assay was very accurate and yielded results consistent with RFMP data. Although the assay has the advantages of automation and short turnaround time, we suggest that further improvements are necessary before it is used routinely in clinical practice. Efforts are needed to decrease cross reactivity among genotypes and to improve the ability to detect minor genotypes in mixed infections.

  20. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  1. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes

    PubMed Central

    Dukić, Lora; Šimundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Introduction: Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Materials and methods: Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Results: Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Conclusion: Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration. PMID:24627723

  2. Comparison of a fluorometric assay kit with high-performance liquid chromatography for the assessment of serum retinol concentration.

    PubMed

    Elom, Aglago Kouassivi; Imane, El Menchawy; Kaoutar, Benjeddou; Khalid, El Kari; Asmaa, El Hamdouchi; Mehdi, Azlaf; Noureddine, El Haloui; Hassan, Aguenaou

    2015-06-01

    Although high-performance liquid chromatography (HPLC) is the commonly used method for the analysis of retinol in biological samples, simple and rapid test kits are available. This study compared a rapid test kit (ICHECK Fluoro®) to HPLC for the assessment of serum retinol concentrations. For the analysis by HPLC, sample preparation included standard deproteinization and extraction phases. The analysis by ICHECK was performed by injecting serum into IEX reagent vials (n=89) and mixing manually for separation. After precipitation of the proteins, the vial was introduced into the chamber of the ICHECK Fluoro and analysed at 0 min (ICHECK0min) and 15 min later (ICHECK15min). Bland and Altman approach was applied to test the agreement between HPLC and ICHECK. Mean HPLC, ICHECK0min and ICHECK15min values were 421.2±106.0 µg/L, 423.1±118.3 µg/L and 413.2±107.6 µg/L, respectively. Retinol concentrations significantly decreased in the IEX solution over time (p<0.001). No significant proportional bias was observed between HPLC and ICHECK0min (r-0.038, p=0.73) and ICHECK15min (r=-0.024, p=0.82). Fixed biases (HPLC minus ICHECK) for ICHECK0min and ICHECK15min were respectively -1.9±23.1 µg/l (p=0.45) and 8.0±22.7 µg/l (p=0.002). ICHECK Fluoro may offer a reliable mean for assessing serum retinol for measurements performed with no significant time delay.

  3. All-in-One Nanowire-Decorated Multifunctional Membrane for Rapid Cell Lysis and Direct DNA Isolation

    PubMed Central

    2015-01-01

    This paper describes a handheld device that uses an all-in-one membrane for continuous mechanical cell lysis and rapid DNA isolation without the assistance of power sources, lysis reagents, and routine centrifugation. This nanowire-decorated multifunctional membrane was fabricated to isolate DNA by selective adsorption to silica surface immediately after disruption of nucleus membranes by ultrasharp tips of nanowires for a rapid cell lysis, and it can be directly assembled with commercial syringe filter holders. The membrane was fabricated by photoelectrochemical etching to create microchannel arrays followed by hydrothermal synthesis of nanowires and deposition of silica. The proposed membrane successfully purifies high-quality DNA within 5 min, whereas a commercial purification kit needs more than an hour. PMID:25420232

  4. Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.

    PubMed

    Xu, Sihong; Song, Aijing; Nie, Jianhui; Li, Xiuhua; Wang, Youchun

    2010-10-01

    Six HIV-1 viral load assays have been widely used in China. These include the Cobas Amplicor HIV-1 Monitor Version 1.5 ('Amplicor'), Cobas AmpliPrep/Cobas TaqMan HIV-1 test Version 1.0 ('CAP/CTM'), Versant HIV-1 RNA Version 3.0 (branched DNA [bDNA]-based assay; 'Versant bDNA'), Abbott RealTime HIV-1 assay ('Abbott RealTime'), NucliSens HIV-1 QT (nucleic acid sequence-based amplification assay; 'NucliSens NASBA'), and NucliSens EasyQ HIV-1 Version 1.1 ('EasyQ V1.1'). Recently, an updated version of EasyQ V1.1, NucliSens EasyQ HIV-1 Version 2.0 ('EasyQ V2.0') was introduced into China. It is important to evaluate the impact of HIV-1 genotypes on the updated assay compared with the other commercial available assays in China. A total of 175 plasma samples with different HIV-1 clades prevalent in China were collected from treatment-naïve patients. The viral loads of those samples were determined with the seven HIV-1 viral load assays, and the quantitative differences between them were evaluated. Overall, EasyQ V2.0 exhibited a significant correlation (R = 0.769-0.850, p ≤ 0.001) and high agreement (94.77-97.13%, using the Bland-Altman model) with the other six assays. Although no significant differences between EasyQ V2.0 and the other six assays were observed when quantifying clade B' samples, there were statistically significant differences between EasyQ V2.0 and the Amplicor, Versant bDNA, and Abbott RealTime assays when quantifying clade BC samples, and between EasyQ V2.0 and the Versant bDNA and Abbott RealTime assays when quantifying clade AE samples. For clade BC samples, the quantitative differences between EasyQ V2.0 and the Amplicor, Versant bDNA, and Abbott RealTime assays exceeded 0.5 log(10) IU/mL in approximately 50% of samples and exceeded 1 log(10) IU/mL in approximately 15% of samples. For clade AE samples, the quantitative differences between EasyQ V2.0 and the CAP/CTM, Versant bDNA, and Abbott RealTime assays exceeded 0.5 log(10) IU/mL in approximately 50% of samples, and the differences between EasyQ V2.0 and CAP/CTM exceeded 1 log(10) IU/mL in approximately 15% of samples. Genotypes may affect the quantification of HIV-1 RNA, especially in clade BC samples with respect to EasyQ V2.0 and the Amplicor, Versant bDNA, or Abbott RealTime assays, and in clade AE samples with respect to EasyQ V2.0 and the Versant bDNA or Abbott RealTime assays. It is therefore strongly suggested that, where possible, the HIV-1 viral load in infected patients be quantified at follow-up by the same version of the same assay that was used initially.

  5. Proactive life extension of pressure vessels

    NASA Astrophysics Data System (ADS)

    Mager, Lloyd

    1998-03-01

    For a company to maintain its competitive edge in today's global market every opportunity to gain an advantage must be exploited. Many companies are strategically focusing on improved utilization of existing equipment as well as regulatory compliance. Abbott Laboratories is no exception. Pharmaceutical companies such as Abbott Laboratories realize that reliability and availability of their production equipment is critical to be successful and competitive. Abbott Laboratories, like many of our competitors, is working to improve safety, minimize downtime and maximize the productivity and efficiency of key production equipment such as the pressure vessels utilized in our processes. The correct strategy in obtaining these objectives is to perform meaningful inspection with prioritization based on hazard analysis and risk. The inspection data gathered in Abbott Laboratories pressure vessel program allows informed decisions leading to improved process control. The results of the program are reduced risks to the corporation and employees when operating pressure retaining equipment. Accurate and meaningful inspection methods become the cornerstone of a program allowing proper preventative maintenance actions to occur. Successful preventative/predictive maintenance programs must utilize meaningful nondestructive evaluation techniques and inspection methods. Nondestructive examination methods require accurate useful tools that allow rapid inspection for the entire pressure vessel. Results from the examination must allow the owner to prove compliance of all applicable regulatory laws and codes. At Abbott Laboratories the use of advanced NDE techniques, primarily B-scan ultrasonics, has provided us with the proper tools allowing us to obtain our objectives. Abbott Laboratories uses B-scan ultrasonics utilizing a pulse echo pitch catch technique to provide essential data on our pressure vessels. Equipment downtime is reduced because the nondestructive examination usually takes place while our vessels are in service. As the inspection takes place we are able to view a real time image of detected discontinuities on a video monitor. The B-scan ultrasonic technique is allowing us to perform fast accurate examinations covering up to 95% of the surface area of each pressure vessel. Receiving data on 95% of a pressure vessel provides us with a lot of useful information. We use this data to determine the condition of each pressure vessel. Once the condition is known the vessels are classed by risk. The risk level is then managed by making decisions related to repair, operating parameters, accepting and monitoring or replacement of the equipment. Inspection schedules are set at maximum intervals and reinspection is minimized for the vessels that are not at risk. The remaining life of each pressure vessel is determined, mechanical integrity is proven and regulatory requirements are met. Abbott Laboratories is taking this proactive approach because we understand that our process equipment is a critical element for successful operation. A run to failure practice would never allow Abbott Laboratories to achieve the corporation's objective of being the world's leading health care company. Nondestructive state of the art technology and the understanding of its capabilities and limitations are key components of a proactive program for life extension of pressure vessels. 26

  6. Revisiting Abbott Thayer: non-scientific reflections about camouflage in art, war and zoology

    PubMed Central

    Behrens, Roy R.

    2008-01-01

    This paper reviews the achievements of Abbott Handerson Thayer (1849–1921), an American painter and naturalist whose pioneering writings on animal camouflage addressed shared concerns among artists, zoologists and military tacticians. It discusses his beliefs about camouflage (both natural and military) in the context of his training as an artist, with particular emphasis on three of his major ideas: countershading, ruptive (or disruptive) coloration and background picturing. PMID:19000975

  7. Results of the Abbott RealTime HIV-1 assay for specimens yielding "target not detected" results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test.

    PubMed

    Babady, N Esther; Germer, Jeffrey J; Yao, Joseph D C

    2010-03-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.

  8. Performance characteristics of the new Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens.

    PubMed

    Vinuesa, Víctor; Navarro, David; Poujois, Sandrine; Zaragoza, Susana; Borrás, Rafael

    2016-03-01

    The performance of the Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens was evaluated using a standard culture as the reference. The overall concordance between both methods was 0.95. The assay displayed an excellent sensitivity (100% for smear-positive/92.3% for smear-negative specimens) and specificity (100%). Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Targeting the unmet medical need: the Abbott Laboratories oncology approach.

    PubMed

    Carlson, Dawn M; Steinberg, Joyce L; Gordon, Gary

    2005-09-01

    While significant advances in the treatment of cancer occured during the last half of the twentieth century, parallel decreases in overall cancer death rates were not observed. Cancer therapy remains an area of significant unmet medical need. Abbott's oncology research programs are focused on pioneering trageted, less toxic therapies, aimed at different aspects of tumor growth and development. Oncology drugs in development at Abbott target several mechanisms of cancer progression by interfering with multiple processes necessary for tumor growth: recruitment of a blood supply, cell proliferation, and the development of metastases. They include a selective endothelin A-receptor antagonist (atrasentan/Xinlay), 3 angiogenesis inhibitors (ABT 510, a thrombospondin mimetic: ABT-869, a multitargeted receptor tyrosine kinase inhibitor; and ABT 828, recombinant human plasminogen kringle 5), a cell proliferation inhibitor (ABT-751, an antimitotic agent), an apoptosis inducer (ABT 737, a Bcl-2 family inhibitor), and a poly(ADP-ribose)polymerase inhibitor.

  10. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    PubMed

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  11. Differences of Cd uptake and expression of OAS and IRT genes in two varieties of ryegrasses.

    PubMed

    Chi, Sunlin; Qin, Yuli; Xu, Weihong; Chai, Yourong; Feng, Deyu; Li, Yanhua; Li, Tao; Yang, Mei; He, Zhangmi

    2018-06-16

    Pot experiment was conducted to study the difference of cadmium uptake and OAS and IRT genes' expression between the two ryegrass varieties under cadmium stress. The results showed that with the increase of cadmium levels, the dry weights of roots of the two ryegrass varieties, and the dry weights of shoots and plants of Abbott first increased and then decreased. When exposed to 75 mg kg -1 Cd, the dry weights of shoot and plant of Abbott reached the maximum, which increased by 11.13 and 10.67% compared with the control. At 75 mg kg -1 Cd, cadmium concentrations in shoot of the two ryegrass varieties were higher than the critical value of Cd hyperaccumulator (100 mg kg -1 ), 111.19 mg kg -1 (Bond), and 133.69 mg kg -1 (Abbott), respectively. The OAS gene expression in the leaves of the two ryegrass varieties showed a unimodal curve, which was up to the highest at the cadmium level of 150 mg kg -1 , but fell back at high cadmium levels of 300 and 600 mg kg -1 . The OAS gene expression in Bond and Abbott roots showed a bimodal curve. The OAS gene expression in Bond root and Abbott stem mainly showed a unimodal curve. The expression of IRT genes family in the leaves of ryegrass varieties was basically in line with the characteristics of unimodal curve, which was up to the highest at cadmium level of 75 or 150 mg kg -1 , respectively. The IRT expression in the ryegrass stems showed characteristics of bimodal and unimodal curves, while that in the roots was mainly unimodal. The expression of OAS and IRT genes was higher in Bond than that in Abbott due to genotype difference between the two varieties. The expression of OAS and IRT was greater in leaves than that in roots and stems. Ryegrass tolerance to cadmium can be increased by increasing the expression of OAS and IRT genes in roots and stems, and transfer of cadmium from roots and stems to the leaves can be enhanced by increasing expression OAS and IRT in leaves.

  12. Orbiting Space Debris: Dangers, Measurement and Mitigation

    DTIC Science & Technology

    1992-06-01

    country1𔃻. In the State of California there Is legal precedent for this type of action In the Sindell vs Abbott Laboratories Case. In this case...interpretation of the treaty and international law. The Sindell vs Abbott case would provide a basis for someone who has lost a satellite to debris to sue the...remain fixed over Panama and Malaysia without the requirement for East-West station-keeping. Satellites could be moved to these locations at the end

  13. Evaluation of subcutaneous glucose monitoring systems under routine environmental conditions in patients with type 1 diabetes.

    PubMed

    Aberer, Felix; Hajnsek, Martin; Rumpler, Markus; Zenz, Sabine; Baumann, Petra M; Elsayed, Hesham; Puffing, Adelheid; Treiber, Gerlies; Pieber, Thomas R; Sourij, Harald; Mader, Julia K

    2017-07-01

    Continuous and flash glucose monitoring (GM) systems have been established in diabetes care. We compared the sensor performance of 3 commercially available GM systems. A total of 12 patients with type 1 diabetes were included in a single-centre, open-label study in which the sensor performance of the Abbott FreeStyle libre (Abbott), Dexcom G4 Platinum (Dexcom) and Medtronic MiniMed 640G (Medtronic) systems over 12 hours was compared during mimicked real-life conditions (meals, exercise, hypo- and hyperglycaemia). Sensor performance was determined by fulfilment of ISO 15197:2013 criteria, calculating mean absolute relative difference (MARD), and was also illustrated using Parkes error grid and Bland-Altman plots. Sensor performance during changes in metabolic variables (lactate, betahydroxybutyrate, glucagon, non-esterified-fatty-acids) was determined by Spearman's rank correlation coefficient testing. The systems fulfilled ISO 15197:2013 criteria by 73.2% (Abbott), 56.1% (Dexcom) and 52.0% (Medtronic). The MARDs ± standard deviation in the entire glycaemic range were 13.2% ± 10.9% (Abbott), 16.8% ± 12.3% (Dexcom) and 21.4% ± 17.6% (Medtronic), respectively. All sensors performed less accurately during hypoglycaemia and best during hyperglycaemia. We did not observe an influence of metabolic variables on sensor performance. © 2017 John Wiley & Sons Ltd.

  14. Improved Analysis of GW150914 Using a Fully Spin-Precessing Waveform Model

    NASA Astrophysics Data System (ADS)

    Abbott, B. P.; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Aiello, L.; Ain, A.; Ajith, P.; Allen, B.; Allocca, A.; Altin, P. A.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C. C.; Areeda, J. S.; Arnaud, N.; Arun, K. G.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Babak, S.; Bacon, P.; Bader, M. K. M.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Baune, C.; Bavigadda, V.; Bazzan, M.; Bejger, M.; Bell, A. S.; Berger, B. K.; Bergmann, G.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Birney, R.; Birnholtz, O.; Biscans, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, S.; Bock, O.; Boer, M.; Bogaert, G.; Bogan, C.; Bohe, A.; Bond, C.; Bondu, F.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Broida, J. E.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brown, N. M.; Brunett, S.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cabero, M.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Calderón Bustillo, J.; Callister, T.; Calloni, E.; Camp, J. B.; Cannon, K. C.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Casanueva Diaz, C.; Casentini, J.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Cerboni Baiardi, L.; Cerretani, G.; Cesarini, E.; Chamberlin, S. J.; Chan, M.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Cheeseboro, B. D.; Chen, H. Y.; Chen, Y.; Cheng, C.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, S.; Chung, S.; Ciani, G.; Clara, F.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Collette, C. G.; Cominsky, L.; Constancio, M.; Conte, A.; Conti, L.; Cook, D.; Corbitt, T. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, C. A.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J.-P.; Countryman, S. T.; Couvares, P.; Cowan, E. E.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Craig, K.; Creighton, J. D. E.; Cripe, J.; Crowder, S. G.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dal Canton, T.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Darman, N. S.; Dasgupta, A.; Da Silva Costa, C. F.; Dattilo, V.; Dave, I.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; De, S.; DeBra, D.; Debreczeni, G.; Degallaix, J.; De Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; DeSalvo, R.; Devine, R. C.; Dhurandhar, S.; Díaz, M. C.; Di Fiore, L.; Di Giovanni, M.; Di Girolamo, T.; Di Lieto, A.; Di Pace, S.; Di Palma, I.; Di Virgilio, A.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Douglas, R.; Downes, T. P.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Ducrot, M.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Engels, W.; Essick, R. C.; Etienne, Z.; Etzel, T.; Evans, M.; Evans, T. M.; Everett, R.; Factourovich, M.; Fafone, V.; Fair, H.; Fairhurst, S.; Fan, X.; Fang, Q.; Farinon, S.; Farr, B.; Farr, W. M.; Fauchon-Jones, E.; Favata, M.; Fays, M.; Fehrmann, H.; Fejer, M. M.; Fenyvesi, E.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Fiori, I.; Fiorucci, D.; Fisher, R. P.; Flaminio, R.; Fletcher, M.; Fournier, J.-D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H. A. G.; Gaebel, S.; Gair, J. R.; Gammaitoni, L.; Gaonkar, S. G.; Garufi, F.; Gaur, G.; Gehrels, N.; Gemme, G.; Geng, P.; Genin, E.; Gennai, A.; George, J.; Gergely, L.; Germain, V.; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.; Glaefke, A.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gonzalez Castro, J. M.; Gopakumar, A.; Gordon, N. A.; Gorodetsky, M. L.; Gossan, S. E.; Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Green, A. C.; Groot, P.; Grote, H.; Grunewald, S.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Hacker, J. J.; Hall, B. R.; Hall, E. D.; Hammond, G.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Hartman, M. T.; Haster, C.-J.; Haughian, K.; Healy, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Henry, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hoak, D.; Hofman, D.; Holt, K.; Holz, D. E.; Hopkins, P.; Hough, J.; Houston, E. A.; Howell, E. J.; Hu, Y. M.; Huang, S.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Indik, N.; Ingram, D. R.; Inta, R.; Isa, H. N.; Isac, J.-M.; Isi, M.; Isogai, T.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jang, H.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jian, L.; Jiménez-Forteza, F.; Johnson, W. W.; Johnson-McDaniel, N. K.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; K, Haris; Kalaghatgi, C. V.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kapadia, S. J.; Karki, S.; Karvinen, K. S.; Kasprzack, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kaur, T.; Kawabe, K.; Kéfélian, F.; Kehl, M. S.; Keitel, D.; Kelley, D. B.; Kells, W.; Kennedy, R.; Key, J. S.; Khalili, F. Y.; Khan, I.; Khan, S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chi-Woong; Kim, Chunglee; Kim, J.; Kim, K.; Kim, N.; Kim, W.; Kim, Y.-M.; Kimbrell, S. J.; King, E. J.; King, P. J.; Kissel, J. S.; Klein, B.; Kleybolte, L.; Klimenko, S.; Koehlenbeck, S. M.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Kringel, V.; Królak, A.; Krueger, C.; Kuehn, G.; Kumar, P.; Kumar, R.; Kuo, L.; Kutynia, A.; Lackey, B. D.; Landry, M.; Lange, J.; Lantz, B.; Lasky, P. D.; Laxen, M.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lebigot, E. O.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Lee, K.; Lenon, A.; Leonardi, M.; Leong, J. R.; Leroy, N.; Letendre, N.; Levin, Y.; Lewis, J. B.; Li, T. G. F.; Libson, A.; Littenberg, T. B.; Lockerbie, N. A.; Lombardi, A. L.; London, L. T.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lousto, C. O.; Lovelace, G.; Lück, H.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magaña-Sandoval, F.; Magaña Zertuche, L.; Magee, R. M.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A. S.; Maros, E.; Martelli, F.; Martellini, L.; Martin, I. W.; Martynov, D. V.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McRae, T.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Meidam, J.; Melatos, A.; Mendell, G.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Mezzani, F.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, A.; Miller, B. B.; Miller, J.; Millhouse, M.; Minenkov, Y.; Ming, J.; Mirshekari, S.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moggi, A.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, B. C.; Moore, C. J.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, D.; Mukherjee, S.; Mukund, N.; Mullavey, A.; Munch, J.; Murphy, D. J.; Murray, P. G.; Mytidis, A.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Nedkova, K.; Nelemans, G.; Nelson, T. J. N.; Neri, M.; Neunzert, A.; Newton, G.; Nguyen, T. T.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E. N.; Nuttall, L. K.; Oberling, J.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oliver, M.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; O'Shaughnessy, R.; Ottaway, D. J.; Overmier, H.; Owen, B. J.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Paris, H. R.; Parker, W.; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patricelli, B.; Patrick, Z.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Perreca, A.; Perri, L. M.; Pfeiffer, H. P.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Poe, M.; Poggiani, R.; Popolizio, P.; Post, A.; Powell, J.; Prasad, J.; Predoi, V.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prix, R.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qi, H.; Qin, J.; Qiu, S.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rajan, C.; Rakhmanov, M.; Rapagnani, P.; Raymond, V.; Razzano, M.; Re, V.; Read, J.; Reed, C. M.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Rew, H.; Reyes, S. D.; Ricci, F.; Riles, K.; Rizzo, M.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, R.; Romanov, G.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Sakellariadou, M.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sanchez, E. J.; Sandberg, V.; Sandeen, B.; Sanders, J. R.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Sauter, O. E. S.; Savage, R. L.; Sawadsky, A.; Schale, P.; Schilling, R.; Schmidt, J.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schönbeck, A.; Schreiber, E.; Schuette, D.; Schutz, B. F.; Scott, J.; Scott, S. M.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Setyawati, Y.; Shaddock, D. A.; Shaffer, T.; Shahriar, M. S.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, A. D.; Singer, A.; Singer, L. P.; Singh, A.; Singh, R.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, J. R.; Smith, N. D.; Smith, R. J. E.; Son, E. J.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Srivastava, A. K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stephens, B. C.; Stevenson, S. P.; Stone, R.; Strain, K. A.; Straniero, N.; Stratta, G.; Strauss, N. A.; Strigin, S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sunil, S.; Sutton, P. J.; Swinkels, B. L.; Szczepańczyk, M. J.; Tacca, M.; Talukder, D.; Tanner, D. B.; Tápai, M.; Tarabrin, S. P.; Taracchini, A.; Taylor, R.; Theeg, T.; Thirugnanasambandam, M. P.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Toland, K.; Tomlinson, C.; Tonelli, M.; Tornasi, Z.; Torres, C. V.; Torrie, C. I.; Töyrä, D.; Travasso, F.; Traylor, G.; Trifirò, D.; Tringali, M. C.; Trozzo, L.; Tse, M.; Turconi, M.; Tuyenbayev, D.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; Vallisneri, M.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; Van Den Broeck, C.; Vander-Hyde, D. C.; van der Schaaf, L.; van der Sluys, M. V.; van Heijningen, J. V.; Vano-Vinuales, A.; van Veggel, A. A.; Vardaro, M.; Vass, S.; Vasúth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Vetrano, F.; Viceré, A.; Vinciguerra, S.; Vine, D. J.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Voss, D. V.; Vousden, W. D.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, M.; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, M.; Wang, X.; Wang, Y.; Ward, R. L.; Warner, J.; Was, M.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Weßels, P.; Westphal, T.; Wette, K.; Whelan, J. T.; Whiting, B. F.; Williams, R. D.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Woehler, J.; Worden, J.; Wright, J. L.; Wu, D. S.; Wu, G.; Yablon, J.; Yam, W.; Yamamoto, H.; Yancey, C. C.; Yu, H.; Yvert, M.; ZadroŻny, A.; Zangrando, L.; Zanolin, M.; Zendri, J.-P.; Zevin, M.; Zhang, L.; Zhang, M.; Zhang, Y.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, X. J.; Zucker, M. E.; Zuraw, S. E.; Zweizig, J.; Boyle, M.; Brügmann, B.; Campanelli, M.; Chu, T.; Clark, M.; Haas, R.; Hemberger, D.; Hinder, I.; Kidder, L. E.; Kinsey, M.; Laguna, P.; Ossokine, S.; Pan, Y.; Röver, C.; Scheel, M.; Szilagyi, B.; Teukolsky, S.; Zlochower, Y.; LIGO Scientific Collaboration; Virgo Collaboration

    2016-10-01

    This paper presents updated estimates of source parameters for GW150914, a binary black-hole coalescence event detected by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 [Abbott et al. Phys. Rev. Lett. 116, 061102 (2016).]. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] presented parameter estimation of the source using a 13-dimensional, phenomenological precessing-spin model (precessing IMRPhenom) and an 11-dimensional nonprecessing effective-one-body (EOB) model calibrated to numerical-relativity simulations, which forces spin alignment (nonprecessing EOBNR). Here, we present new results that include a 15-dimensional precessing-spin waveform model (precessing EOBNR) developed within the EOB formalism. We find good agreement with the parameters estimated previously [Abbott et al. Phys. Rev. Lett. 116, 241102 (2016).], and we quote updated component masses of 35-3+5 M⊙ and 3 0-4+3 M⊙ (where errors correspond to 90% symmetric credible intervals). We also present slightly tighter constraints on the dimensionless spin magnitudes of the two black holes, with a primary spin estimate <0.65 and a secondary spin estimate <0.75 at 90% probability. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] estimated the systematic parameter-extraction errors due to waveform-model uncertainty by combining the posterior probability densities of precessing IMRPhenom and nonprecessing EOBNR. Here, we find that the two precessing-spin models are in closer agreement, suggesting that these systematic errors are smaller than previously quoted.

  15. Kidney Injury Molecule Levels in Type 2 Diabetes Mellitus.

    PubMed

    Aslan, Ozgur; Demir, Metin; Koseoglu, Mehmet

    2016-11-01

    This study was designed to determine the diagnostic role of urinary kidney injury molecule (KIM)-1 levels in renal damage in patients with type 2 diabetes mellitus according to the urinary albumin/creatinine ratio. Patients with type 2 diabetes mellitus admitted to different polyclinics in our hospital enrolled in the study and were subdivided into three groups according to albumin/creatinine ratio - normalbuminuric (n: 20); microalbuminuric (n: 20); albuminuric (n: 18) - and compared with the control group. Urine albumin was analyzed using the immunoturbidimetric method (Architect C16000, Abbott Diagnostics). uKIM-1 was determined using a commercially available enzyme-linked immunosorbent assay test kit (USCN Life Science, Hankou, Wuhan, China). One-sample Kolmogorov-Smirnov test, Spearman correlation and Kruskal-Wallis non-parametric tests were performed. Post hoc comparisons were made using Bonferroni-corrected Mann-Whitney U tests. The differences between the controls and normalbuminuric, microalbuminuric and albuminuric groups were highly significant for KIM-1. Positive correlation was found between KIM-1 and urine microalbumin-urine microalbumin/creatinine (r = 0.479 P < 0.001; r = 0. 400, P < 0.001; respectively). In our study, KIM-1 levels were significantly different suggesting that urinary KIM-1 levels may be an early marker in patients with diabetic nephropathy. J. Clin. Lab. Anal. 00:1-6, 2016. © 2016 Wiley Periodicals, Inc.

  16. Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya.

    PubMed

    Zeh, Clement; Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John

    2017-01-01

    Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90.4% [95% CI 78.2-96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3-97.5] and 98.1% [95%CI 88.4-99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0-98.3] and specificity of 82.7% [95%CI 69.2-91.3]). There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings.

  17. Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya

    PubMed Central

    Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John

    2017-01-01

    Background Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Methods Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Results Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2–99.2] and 98.1% [95%CI: 89.7–100]) and those for DBS (93.9% [95%CI: 88.8–97.2] and 88.0% [95%CI: 82.2–92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4–97.7) and 73.6 (95%CI: 51.6–86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6–100.0] vs. 94.7% [95%CI: 89.8–97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4–13.7] compared to DPS: 94.0%, [95% CI: 83.5–98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8–98.7] and 90.4% [95% CI 78.2–96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3–97.5] and 98.1% [95%CI 88.4–99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0–98.3] and specificity of 82.7% [95%CI 69.2–91.3]). Conclusions There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings. PMID:28622370

  18. Fully Automated Quantification of Cytomegalovirus (CMV) in Whole Blood with the New Sensitive Abbott RealTime CMV Assay in the Era of the CMV International Standard

    PubMed Central

    Schnepf, Nathalie; Scieux, Catherine; Resche-Riggon, Matthieu; Feghoul, Linda; Xhaard, Alienor; Gallien, Sébastien; Molina, Jean-Michel; Socié, Gérard; Viglietti, Denis; Simon, François; Mazeron, Marie-Christine

    2013-01-01

    Fully standardized reproducible and sensitive quantification assays for cytomegalovirus (CMV) are needed to better define thresholds for antiviral therapy initiation and interruption. We evaluated the newly released Abbott RealTime CMV assay for CMV quantification in whole blood (WB) that includes automated extraction and amplification (m2000 RealTime system). Sensitivity, accuracy, linearity, and intra- and interassay variability were validated in a WB matrix using Quality Control for Molecular Diagnostics (QCMD) panels and the WHO international standard (IS). The intra- and interassay coefficients of variation were 1.37% and 2.09% at 5 log10 copies/ml and 2.41% and 3.80% at 3 log10 copies/ml, respectively. According to expected values for the QCMD and Abbott RealTime CMV methods, the lower limits of quantification were 104 and <50 copies/ml, respectively. The conversion factor between international units and copies (2.18), determined from serial dilutions of the WHO IS in WB, was significantly different from the factor provided by the manufacturer (1.56) (P = 0.001). Results from 302 clinical samples were compared with those from the Qiagen artus CMV assay on the same m2000 RealTime system. The two assays provided highly concordant results (concordance correlation coefficient, 0.92), but the Abbott RealTime CMV assay detected and quantified, respectively, 20.6% and 47.8% more samples than the Qiagen/artus CMV assay. The sensitivity and reproducibility of the results, along with the automation, fulfilled the quality requirements for implementation of the Abbott RealTime CMV assay in clinical settings. Our results highlight the need for careful validation of conversion factors provided by the manufacturers for the WHO IS in WB to allow future comparison of results obtained with different assays. PMID:23616450

  19. Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

    PubMed

    Gaydos, C A; Cartwright, C P; Colaninno, P; Welsch, J; Holden, J; Ho, S Y; Webb, E M; Anderson, C; Bertuzis, R; Zhang, L; Miller, T; Leckie, G; Abravaya, K; Robinson, J

    2010-09-01

    A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians.

  20. Performance of the Abbott RealTime CT/NG for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae▿

    PubMed Central

    Gaydos, C. A.; Cartwright, C. P.; Colaninno, P.; Welsch, J.; Holden, J.; Ho, S. Y.; Webb, E. M.; Anderson, C.; Bertuzis, R.; Zhang, L.; Miller, T.; Leckie, G.; Abravaya, K.; Robinson, J.

    2010-01-01

    A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians. PMID:20668135

  1. Evaluation of Sensitivity and Specificity Performance of Elecsys HTLV-I/II Assay in a Multicenter Study in Europe and Japan.

    PubMed

    Laperche, Syria; Sauleda, Silvia; Piron, Maria; Mühlbacher, Annelies; Schennach, Harald; Schottstedt, Volkmar; Queirós, Lucinda; Uno, Naoki; Yanagihara, Katsunori; Imdahl, Roland; Hey, Ariann; Klinkicht, Markus; Melchior, Walter; Muench, Peter; Watanabe, Toshiki

    2017-07-01

    Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection. Copyright © 2017 Laperche et al.

  2. Evaluation of Sensitivity and Specificity Performance of Elecsys HTLV-I/II Assay in a Multicenter Study in Europe and Japan

    PubMed Central

    Sauleda, Silvia; Piron, Maria; Mühlbacher, Annelies; Schennach, Harald; Schottstedt, Volkmar; Queirós, Lucinda; Uno, Naoki; Yanagihara, Katsunori; Imdahl, Roland; Hey, Ariann; Klinkicht, Markus; Melchior, Walter; Muench, Peter; Watanabe, Toshiki

    2017-01-01

    ABSTRACT Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection. PMID:28468860

  3. Evaluation of lot-to-lot repeatability and effect of assay media choice in the recombinant Factor C assay.

    PubMed

    McKenzie, Jennifer Helen; Alwis, K Udeni; Sordillo, Joanne E; Kalluri, Kesava Srinivas; Milton, Donald Kirby

    2011-06-01

    Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and assay media, to endotoxin estimates previously obtained by Limulus amebocyte lysate (LAL) assay and amounts of 3-hydroxy fatty acids (3-OHFA) in lipopolysaccharide (LPS) using gas-chromatography mass spectroscopy (GC-MS). We found that lot-to-lot variability of the rFC assay kits does not significantly alter endotoxin estimates in house dust samples when performed using three of the four assay media tested and that choice of assay media significantly altered endotoxin estimates obtained by rFC assay of house dust samples. Our findings demonstrate lot-to-lot reproducibility of rFC assay of environmental samples and suggest that use of rFC assay performed with Tris buffer or water as the extraction and assay medium for measurement of endotoxin in dust samples may be a suitable choice for developing a standardized methodology.

  4. A technical assessment of the porcine ejaculated spermatozoa for a sperm-specific RNA-seq analysis.

    PubMed

    Gòdia, Marta; Mayer, Fabiana Quoos; Nafissi, Julieta; Castelló, Anna; Rodríguez-Gil, Joan Enric; Sánchez, Armand; Clop, Alex

    2018-04-26

    The study of the boar sperm transcriptome by RNA-seq can provide relevant information on sperm quality and fertility and might contribute to animal breeding strategies. However, the analysis of the spermatozoa RNA is challenging as these cells harbor very low amounts of highly fragmented RNA, and the ejaculates also contain other cell types with larger amounts of non-fragmented RNA. Here, we describe a strategy for a successful boar sperm purification, RNA extraction and RNA-seq library preparation. Using these approaches our objectives were: (i) to evaluate the sperm recovery rate (SRR) after boar spermatozoa purification by density centrifugation using the non-porcine-specific commercial reagent BoviPure TM ; (ii) to assess the correlation between SRR and sperm quality characteristics; (iii) to evaluate the relationship between sperm cell RNA load and sperm quality traits and (iv) to compare different library preparation kits for both total RNA-seq (SMARTer Universal Low Input RNA and TruSeq RNA Library Prep kit) and small RNA-seq (NEBNext Small RNA and TailorMix miRNA Sample Prep v2) for high-throughput sequencing. Our results show that pig SRR (~22%) is lower than in other mammalian species and that it is not significantly dependent of the sperm quality parameters analyzed in our study. Moreover, no relationship between the RNA yield per sperm cell and sperm phenotypes was found. We compared a RNA-seq library preparation kit optimized for low amounts of fragmented RNA with a standard kit designed for high amount and quality of input RNA and found that for sperm, a protocol designed to work on low-quality RNA is essential. We also compared two small RNA-seq kits and did not find substantial differences in their performance. We propose the methodological workflow described for the RNA-seq screening of the boar spermatozoa transcriptome. FPKM: fragments per kilobase of transcript per million mapped reads; KRT1: keratin 1; miRNA: micro-RNA; miscRNA: miscellaneous RNA; Mt rRNA: mitochondrial ribosomal RNA; Mt tRNA: mitochondrial transference RNA; OAZ3: ornithine decarboxylase antizyme 3; ORT: osmotic resistance test; piRNA: Piwi-interacting RNA; PRM1: protamine 1; PTPRC: protein tyrosine phosphatase receptor type C; rRNA: ribosomal RNA; snoRNA: small nucleolar RNA; snRNA: small nuclear RNA; SRR: sperm recovery rate; tRNA: transfer RNA.

  5. Distribution and predominance of genotype 3 in hepatitis C virus carriers in the province of kahramanmaras, Turkey.

    PubMed

    Caliskan, Ahmet; Kirisci, Ozlem; Ozkaya, Esra; Ozden, Sevinc; Tumer, Seray; Caglar, Serkan; Guler, Selma Ates; Senol, Hande

    2015-04-01

    The hepatitis C virus (HCV) has six major genotypes and more than 100 subtypes, and the determination of the responsible genotype, collection of epidemiological data, tailoring antiviral therapy, and prediction of prognosis have an important place in disease management. The aim of the present study was to determine the distribution of HCV genotypes across geographic regions and compare these data with those obtained from other geographic locations. The HCV genotypes were identified in HCV RNA positive blood samples, obtained from different centers. The HCV genotype was determined using molecular methods [Real-Time Polymerase Chain Reaction (RT-PCR)] in 313 patients, who were found to be positive for HCV RNA. The presence of HCV RNA was investigated using the RT-PCR method in serum samples delivered to the Microbiology Laboratory at Kahramanmaras Necip Fazıl City Hospital, Kahramanmaras, Turkey, from the centers located in Kahramanmaras City center and peripheral districts of the province, between March 2010 and August 2014. The HCV genotype analysis was performed in HCV RNA positive samples, using RT-PCR reagents kit. Urine samples from the patients were tested for amphetamine with an Amphetamines II (AMPS2) kit, cocaine was tested with a Cocaine II (COC2) kit, opiates were tested with an Opiates II (OPI2) kit, and cannabinoids were tested with a Cannabinoids II (THC2) kit in Roche/Hitachi Cobas c501 device. The blood samples collected from 313 patients were included in the study. Of these patients, 212 (67.7%) were male and 101 (32.3%) were female. The mean age of the patients was 41.29 ± 20.32 years. In terms of HCV genotype distribution, 162 patients (51.7%) had genotype 1, 144 patients (46%) had genotype 3, four patients (1.3%) had genotype 2, and three patients (1%) had genotype 4. The results of urine drug tests were available in only 65 patients (20.2%). Of these, 61 (93.8%) patients had HCV genotype 3. In conclusion, the prevalence of HCV genotype 1 was 51.7%, which was lower than the rates reported in other studies in Turkey, while the prevalence of HCV genotype 3 was 46%, which was remarkably higher than the reported Turkish data. In addition, the prevalence rate for genotype 3 reported in the present study is the highest that has ever been reported in the literature.

  6. BRSCW Reference Set Application: Karen Abbott -University of Arkansas (2014) — EDRN Public Portal

    Cancer.gov

    Our earlier glycoproteomic studies have identified bisecting glycoslyation and core fucosylation changes on particular glycoproteins in endometrioid ovarian cancer tissues and plasma (Abbott et al, 2010, Proteomics). We have validated that these glycan changes occur on the same glycoproteins in serous ovarian cancer plasma using a lectin-pull down western blot assays. We would like to used pooled reference samples to develop a sensitive magnetic bead-based assay to detect these glycoproteins with bisecting and core fucosylation changes.

  7. Derivation of Candidates for the Combat Casualty Critical Care (C4) Database

    DTIC Science & Technology

    2014-04-01

    James D. Oliver, MC USA∥; COL Kevin C. Abbott , MC USA∥; John A. Jones, BS§; LTC Kevin K. Chung, MC USA§ ABSTRACT Objective: To describe the...the purposes of epidemiologic studies.13 Furthermore, laboratory data from the JTTR are limited to blood gases, international normalized ratios...Cannon J. W., Zonies D. H., Morrow B. D., Orman J. A., Oliver J. D., Abbott K. C., Jones J. A., Chung K. K., 5d. PROJECT NUMBER 5e. TASK NUMBER

  8. An Archeological Survey of Two Proposed Reservoir Areas, Rocky River Basin, North Carolina,

    DTIC Science & Technology

    1987-08-01

    J. 1942 An Ecological Analysis of the Plant Communities of the Piedmont, North Carolina. The American Midland Naturalist 28:1-126. S ,% ".dl Page 10...Chapter 6. While each chapter in the report is in part at least a team result, certain individuals had primary responsibility for analysis and write...Chapter 5 by Dull; Chapter 6 by Sanborn; Chapter 7 by Vacca; Chapter 8 by Abbott; and Chapter 9 by Abbott and Woodall. The computer work during analysis and

  9. Development, evaluation, and laboratory validation of immunoassays for the diagnosis of equine infectious anemia (EIA) using recombinant protein produced from a synthetic p26 gene of EIA virus.

    PubMed

    Singha, Harisankar; Goyal, Sachin K; Malik, Praveen; Khurana, Sandip K; Singh, Raj K

    2013-12-01

    Equine infectious anemia (EIA)-a retroviral disease caused by equine infectious anemia virus (EIAV)-is a chronic, debilitating disease of horses, mules, and donkeys. EIAV infection has been reported worldwide and is recognized as pathogen of significant economic importance to the horse industry. This disease falls under regulatory control program in many countries including India. Control of EIA is based on identification of inapparent carriers by detection of antibodies to EIAV in serologic tests and "Stamping Out" policy. The current internationally accepted test for diagnosis of EIA is the agar gel immune-diffusion test (AGID), which detects antibodies to the major gag gene (p26) product. The objective of this study was to develop recombinant p26 based in-house immunoassays [enzyme linked immunosorbent assays (ELISA), and AGID] for EIA diagnosis. The synthetic p26 gene of EIAV was expressed in Escherichia coli and diagnostic potential of recombinant p26 protein were evaluated in ELISA and AGID on 7,150 and 1,200 equine serum samples, respectively, and compared with commercial standard AGID kit. The relative sensitivity and specificity of the newly developed ELISA were 100 and 98.6 %, respectively. Whereas, relative sensitivity and specificity of the newly developed AGID were in complete agreement in respect to commercial AGID kit. Here, we have reported the validation of an ELISA and AGID on large number of equine serum samples using recombinant p26 protein produced from synthetic gene which does not require handling of pathogenic EIAV. Since the indigenously developed reagents would be economical than commercial diagnostic kit, the rp26 based-immunoassays could be adopted for the sero-diagnosis and control of EIA in India.

  10. Evaluation of the highly sensitive chemiluminescent enzyme immunoassay "Lumipulse HBsAg-HQ" for hepatitis B virus screening.

    PubMed

    Deguchi, Matsuo; Kagita, Masanori; Yoshioka, Nori; Tsukamoto, Hiroko; Takao, Miyuki; Tahara, Kazuko; Maeda, Ikuhiro; Hidaka, Yoh; Yamauchi, Satoshi; Kaneko, Atsushi; Miyakoshi, Hideo; Isomura, Mitsuo

    2017-10-06

    Ongoing efforts in the development of HBsAg detection kits are focused on improving sensitivity and specificity. The purpose of this study was to evaluate an improved, highly sensitive quantitative assay, "Lumipulse HBsAg-HQ", a chemiluminescent enzyme immunoassay designed for a fully automated instrument, the "Lumipulse G1200". Serum samples for reproducibility, dilution, correlation, sensitivity, and specificity studies were obtained from patients at the Osaka University Hospital. Seroconversion and sensitivity panels were purchased from a commercial vender. Subtype, sensitivity panels, and HBsAg recombinant proteins with one or two amino acid substitutions were prepared in-house. The coefficients of variation for the low, medium, and high concentration samples ranged from 1.93 to 2.55%. The HBsAg-HQ reagent for dilution testing showed good linearity in the 0.005-150 HBsAg IU/mL range and no prozone phenomenon. All 102 HBV carrier samples were positive by HBsAg-HQ, while other commercial reagents showed one or more to be negative. In the seroconversion panel, the 14-day blood sample was positive. The sensitivity against HBsAg-HQ "ad" and "ay" subtypes was 0.025 ng/mL. Comparisons among the HBsAg-HQ, HISCL, and Architect HBsAg reagents were performed using the Bland-Altman plot. Specificity for 1000 seronegative individuals was 99.7%. HBsAg-HQ detected 29 positive serum among 12 231 routinely obtained serum samples, which showed concentrations of 0.005-0.05 HBsAg IU/mL. According to these results, the Lumipulse HBsAg-HQ assay, with a highly sensitive limit of detection of 0.005 IU/mL, may facilitate the development of a better management strategy for a considerable proportion of infected patients. © 2017 Wiley Periodicals, Inc.

  11. Improved Analysis of GW150914 Using a Fully Spin-Precessing Waveform Model

    NASA Technical Reports Server (NTRS)

    Abbott, B. P.; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Camp, J. B.; hide

    2016-01-01

    This paper presents updated estimates of source parameters for GW150914, a binary black-hole coalescence event detected by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 [Abbott et al. Phys. Rev. Lett. 116, 061102 (2016).]. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] presented parameter estimation of the source using a 13-dimensional, phenomenological precessing-spin model (precessing IMRPhenom) and an 11-dimensional nonprecessing effective-one-body (EOB) model calibrated to numerical-relativity simulations, which forces spin alignment (nonprecessing EOBNR). Here, we present new results that include a 15-dimensional precessing-spin waveform model (precessing EOBNR) developed within the EOB formalism. We find good agreement with the parameters estimated previously [Abbott et al. Phys. Rev. Lett. 116, 241102 (2016).], and we quote updated component masses of 35(+5)(-3) solar M; and 30(+3)(-4) solar M; (where errors correspond to 90 symmetric credible intervals). We also present slightly tighter constraints on the dimensionless spin magnitudes of the two black holes, with a primary spin estimate is less than 0.65 and a secondary spin estimate is less than 0.75 at 90% probability. Abbott et al. [Phys. Rev. Lett. 116, 241102 (2016).] estimated the systematic parameter-extraction errors due to waveform-model uncertainty by combining the posterior probability densities of precessing IMRPhenom and nonprecessing EOBNR. Here, we find that the two precessing-spin models are in closer agreement, suggesting that these systematic errors are smaller than previously quoted.

  12. MAO enzymes inhibitory activity of new benzimidazole derivatives including hydrazone and propargyl side chains.

    PubMed

    Can, Özgür Devrim; Osmaniye, Derya; Demir Özkay, Ümide; Sağlık, Begüm Nurpelin; Levent, Serkan; Ilgın, Sinem; Baysal, Merve; Özkay, Yusuf; Kaplancıklı, Zafer Asım

    2017-05-05

    In the present work, 15 new N'-(arylidene)-4-(1-(prop-2-yn-1-yl)-1H-benzo[d]imidazol-2-yl)benzohydrazide (4a-4o) were designed and synthesized. The structures of the synthesized compounds were elucidated using FT-IR, 1 H-NMR, 13 C-NMR, and HRMS spectral data. The inhibitory activity of the compounds 4a-4o against hMAO-A and hMAO-B enzymes was evaluated by using in vitro Amlex Red ® reagent based fluorometric method. Due to lots of high-cost kits including this assay, we determined the ingredients of the kits from the data sheets of several suppliers, and adjusted a protocol by working with various concentrations and volumes of these ingredients. As a result, a fast and sensitive assay was applied as in the commercially available MAO kits with lower costs and clearer ingredients than those of the kits. The enzyme inhibition assay revealed that synthesized compounds have selective inhibition potency against hMAO-B. The compound 4e and 4f displayed IC 50 values of 0.075 μM and 0.136 μM against hMAO-B, respectively. The reference drugs selegiline (IC 50  = 0.040 μM) and rasagiline (IC 50  = 0.066 μM) also displayed a significant inhibition against hMAO-B. The enzyme kinetic study was performed in order to observe the effect of the most active compound 4e on substrate-enzyme relationship and non-competitive inhibition of hMAO-B was determined. Cytotoxicity and genotoxicity studies were carried out and the compound 4e was found as non-cytotoxic and non-genotixic. Theoretical calculation of ADME properties suggested that compound 4e may have a good pharmacokinetic profile. The docking study of compound 4e revealed that there is a strong interaction between the active sites of hMAO-B and analyzed compound. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. Performance of the Abbott RealTime HIV-1 Viral Load Assay Is Not Impacted by Integrase Inhibitor Resistance-Associated Mutations▿

    PubMed Central

    Young, Thomas P.; Cloherty, Gavin; Fransen, Signe; Napolitano, Laura; Swanson, Priscilla; Herman, Christine; Parkin, Neil T.; Hackett, John

    2011-01-01

    The Abbott RealTime HIV-1 viral load assay uses primers and probes targeted to integrase, which is also the target of integrase inhibitors such as raltegravir. Viral loads of 42 raltegravir-susceptible and 40 raltegravir-resistant specimens were determined using RealTime HIV-1 and Roche Monitor (v1.5). The differences in viral load measurements between assays were comparable in the two groups, demonstrating that the RealTime HIV-1 assay can tolerate raltegravir-selected mutations. PMID:21289145

  14. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    PubMed Central

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring. PMID:23946517

  15. Application of a newly developed high-sensitivity HBsAg chemiluminescent enzyme immunoassay for hepatitis B patients with HBsAg seroclearance.

    PubMed

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-11-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring.

  16. Case study: improving efficiency in a large hospital laboratory.

    PubMed

    Bartel, Marilynn

    2004-01-01

    Saint Francis Health System (SFHS) consists of three hospitals and one clinic: Saint Francis Hospital (SFH); Broken Arrow Medical Center; Laureate Psychiatric Hospital; and Warren Clinic. SFHS has 670 physicians on staff and serves medical (oncology, orthopedic, neurology, and renal), surgical, cardiac, women and infant, pediatric, transplant, and trauma patients in Tulsa County, Oklahoma, which has a population of 660,000. SFH incorporates 706 staffed beds, including 126 pediatric beds and 119 critical care beds. Each year, the health system averages 38,000 admissions, 70,000 emergency department visits, 25,000 surgeries, and 3,500 births. Saint Francis Laboratory is located within the main hospital facility (SFH) and functions as a core lab for the health system. The lab also coordinates lab services with Saint Francis Heart Hospital, a physician-system joint venture. The Optimal Equipment Configuration (OEC) Project was designed by the Clinical Laboratory Services division of Premier, a group purchasing organization, with the goal of determining whether laboratories could improve efficiency and decrease unit cost by using a single-source vendor. Participants included seven business partners (Abbott, Bayer, Beckman/Coulter, Dade/Behring, J&J/ Ortho, Olympus, and Roche) and 21 laboratory sites (a small, mid-sized, and large site for each vendor). SFH laboratory staff embraced Premier's concept and viewed the OEC project as an opportunity to "energize" laboratory operations. SFH partnered with Abbott, their primary equipment vendor, for the project. Using resources and tools made available through the project, the laboratory was re-engineered to simplify workflow, increase productivity, and decrease costs by adding automation and changing to centralized specimen processing. Abbott and SFH shared a common vision for the project and enhanced their partnership through increased communication and problem solving. Abbott's area representatives provided for third-party design expertise and quarterly metric reporting through Argent Consulting. Abbott incorporated lessons learned from the SFH OEC project with organizational changes to improve the way they work with customers. Following is a step-by-step description of the OEC project to allow others to benefit from the experience (Figure 1).

  17. Infant formula companies battle for breast.

    PubMed

    1996-01-01

    The infant formula manufacturer Mead Johnson has filed a lawsuit in Ontario courts against its competitor Ross Abbott for false advertising of its new Similac brand of infant formula. Mead Johnson contends that the Ross Abbott advertisement of Similac as providing benefits similar to mother's milk is false and misleading. Breast feeding specialists agree with Mead Johnson's claim. Yet, one year earlier, Mead Johnson claimed that its infant formula is modeled after mother's milk. The Infant Feeding Action Coalition (INFACT) Canada had complained to the Competition Bureau that called for Mead Johnson to cease its claim. Court documents reveal that both companies disregard the World Health Organization (WHO) International Code of Marketing of Breast Milk Substitutes. This code prohibits manufacturers from advertising directly to pregnant women and mothers. Two Ross Abbott spokespersons have different responses to their advertising practices: increasing emphasis on consumer promotion and support of the principle and objective of the WHO Code. Both companies have sought support of health professionals in Canada. In July 1996 Mead Johnson sent letters to about 7000 clinicians declaring "as someone who cares about infant health and nutrition as much as we do" and "...the most alarming concern is that, although there is no scientific basis for such claims, mothers believe them to be true." Ross Abbott responded to these letters by sending physicians letters declaring "Our business is built on trust, and we assure you that you may trust in Similac Advance and the benefits we have ascribed to it." The two companies will meet again in court on September 30, 1996.

  18. The Student-to-Student Chemistry Initiative: Training High School Students To Perform Chemistry Demonstration Programs for Elementary School Students

    NASA Astrophysics Data System (ADS)

    Voegel, Phillip D.; Quashnock, Kathryn A.; Heil, Katrina M.

    2004-05-01

    The Student-to-Student Chemistry Initiative is an outreach program started in the fall of 2001 at Midwestern State University (MSU). The oncampus program trains high school science students to perform a series of chemistry demonstrations and subsequently provides kits containing necessary supplies and reagents for the high school students to perform demonstration programs at elementary schools. The program focuses on improving student perception of science. The program's impact on high school student perception is evaluated through statistical analysis of paired preparticipation and postparticipation surveys. The surveys focus on four areas of student perception: general attitude toward science, interest in careers in science, science awareness, and interest in attending MSU for postsecondary education. Increased scores were observed in all evaluation areas including a statistically significant increase in science awareness following participation.

  19. Insulin-like growth factor-binding protein-3 (IGFBP-3) but not insulin-like growth factor-I (IGF-I) remains elevated in euthyroid TSH-suppressed Graves' disease.

    PubMed

    Wan Nazaimoon, W M; Khalid, B A

    1998-04-01

    Thyroid hormones have been shown to be involved in the regulation of insulin-like growth factor-I (IGF-I) and IGF binding protein-3 (IGFBP-3) expression. This is a cross-sectional study to look at the effects of thyroid hormone status on the circulating levels of IGF-I and IGFBP-3 in a group of 127 patients, aged 20-80 years, who were hyperthyroid, hypothyroid, rendered euthyroid and clinically euthyroid with normal free thyroxine (fT4), but suppressed thyroid stimulating hormone (TSH) levels. TSH was measured by the IMx (Abbott) ultrasensitive assay, while radioimmunoassays for total T3 and T4 were performed using kits from ICN, USA; fT4 and fT3 using kits from DPC USA; IGF-I and IGFBP-3 using kits from Nichols Institute Diagnostics B.V., Netherlands. Differences in the levels of IGF-I between the 4 groups of patients were significant only in the patients aged 20-40. Mean (+/-SEM) IGF-I levels of hypothyroid patients (169+/-19ng/ml) was significantly lower than hyperthyroid (315+/-26 ng/ml, p=0.003), euthyroid patients (241+/-19 ng/ml, p=0.002) and patients with suppressed TSH (308+/-29 ng/ml, p=0.02). The IGF-I levels of the hyperthyroid and suppressed TSH patients were, however, comparable to age-matched normal subjects (281+/-86 ng/ml). Although there was no difference in mean IGFBP-3 levels between the 4 groups of patients, the levels in the patients aged 20-40 with hyperthyroidism (3.7+/-0.9 microg/ml) and suppressed TSH (3.9+/-1.2 microg/ml) were significantly higher (p=0.02) than age-matched normal subjects (3.1+/-0.8 microg/ml). The IGF-I levels of the thyroid patients aged 20-40 showed significant negative correlation to TSH and positive correlations to the thyroid hormones. Hence, whilst low IGF-I is associated with hypothyroidism, high IGFBP-3 is associated with hyperthyroidism. Our finding that IGFBP-3 remained significantly elevated in patients with suppressed TSH but normalised fT4 and fT3 is important as it suggests a prolonged tissue effect of thyroid hormones on IFGBP-3. As such patients have been shown to have higher risk for atrial fibrillation, the significance and possible role of IGFBP-3 in these conditions should be further elucidated in future studies.

  20. Test results for the evaluation of a glucometer for use under hyperbaric conditions: Technical report.

    PubMed

    Tsouras, Theo

    2017-01-01

    This study aimed to evaluate a recently developed equipment test method by assessing the safe and accurate functioning of the Abbott Optium FreeStyle H portable blood glucose monitor for use in the Alfred Hospital's hyperbaric chamber. The results of this study indicate that the test method can be used successfully to evaluate instruments and/or devices for use in the hyperbaric environment. The evaluation initially found that this particular glucose monitor contained a lithium battery which can be hazardous when used in the hyperbaric environment. However, upon further inspection it was determined the battery posed minimal risk for fire and explosion due to its small capacity and design application. The results indicate that the Abbott Optium FreeStyle H blood glucose monitor operated normally when used in the hyperbaric chamber. This glucometer was found to perform within the calibration specification requirements for accuracy at all stages of a typical hyperbaric treatment and as such the Abbott Optium FreeStyle H blood glucose monitor was deemed safe for use in the hyperbaric chamber at the Alfred Hospital. Copyright© Undersea and Hyperbaric Medical Society.

  1. Clinical laboratory investigation of the Sanofi ACCESS CK-MB procedure and comparison to electrophoresis and Abbott IMx.

    PubMed

    Mao, G D; Adeli, K; Eisenbrey, A B; Artiss, J D

    1996-07-01

    This evaluation was undertaken to verify the application protocol for the CK-MB assay on the ACCESS Immunoassay Analyzer (Sanofi Diagnostics Pasteur, Chaska, MN). The results show that the ACCESS CK-MB assay total imprecision was 6.8% to 9.1%. Analytical linearity of the ACCESS CK-MB assay was excellent in the range of < 1-214 micrograms/L. A comparison of the ACCESS CK-MB assay with the IMx (Abbott Laboratories, Abbott Park, IL) method shows good correlation r = 0.990 (n = 108). Linear regression analysis yielded Y = 1.36X-0.3, Sx/y = 7.2. ACCESS CK-MB values also correlated well with CK-MB by electrophoresis with r = 0.968 (n = 132). The linear regression equation for this comparison was Y = 1.08X + 1.4, Sx/y = 14.1. The expected non-myocardial infarction range of CK-MB determined by the ACCESS system was 1.3-9.4 micrograms/L (mean = 4.0, n = 58). The ACCESS CK-MB assay would appear to be rapid, precise and clinically useful.

  2. Substituting Sodium Hydrosulfite with Sodium Metabisulfite Improves Long-Term Stability of a Distributable Paper-Based Test Kit for Point-of-Care Screening for Sickle Cell Anemia.

    PubMed

    Torabian, Kian; Lezzar, Dalia; Piety, Nathaniel Z; George, Alex; Shevkoplyas, Sergey S

    2017-09-20

    Sickle cell anemia (SCA) is a genetic blood disorder that is particularly lethal in early childhood. Universal newborn screening programs and subsequent early treatment are known to drastically reduce under-five SCA mortality. However, in resource-limited settings, cost and infrastructure constraints limit the effectiveness of laboratory-based SCA screening programs. To address this limitation our laboratory previously developed a low-cost, equipment-free, point-of-care, paper-based SCA test. Here, we improved the stability and performance of the test by replacing sodium hydrosulfite (HS), a key reducing agent in the hemoglobin solubility buffer which is not stable in aqueous solutions, with sodium metabisulfite (MS). The MS formulation of the test was compared to the HS formulation in a laboratory setting by inexperienced users ( n = 3), to determine visual limit of detection (LOD), readout time, diagnostic accuracy, intra- and inter-observer agreement, and shelf life. The MS test was found to have a 10% sickle hemoglobin LOD, 21-min readout time, 97.3% sensitivity and 99.5% specificity for SCA, almost perfect intra- and inter-observer agreement, at least 24 weeks of shelf stability at room temperature, and could be packaged into a self-contained, distributable test kits comprised of off-the-shelf disposable components and food-grade reagents with a total cost of only $0.21 (USD).

  3. Anti-inflammatory potential of ellagic acid, gallic acid and punicalagin A&B isolated from Punica granatum.

    PubMed

    BenSaad, Lamees A; Kim, Kah Hwi; Quah, Chin Chew; Kim, Wee Ric; Shahimi, Mustafa

    2017-01-14

    Punica granatum (pomegranate), an edible fruit originating in the Middle East, has been used as a traditional medicine for treatment of pain and inflammatory conditions such as peptic ulcer. The numerous risks associated with nonsteroidal anti-inflammatory drugs (NSAIDs) for treatment of pain and inflammation give rise to using medicinal herbs as alternative therapies. This study aimed to evaluate the anti-inflammatory effect of isolated compounds from the ethyl acetate (EtOAc) fraction of P. granatum by determination of their inhibitory effects on lipopolysaccharide (LPS), stimulated nitric oxide (NO), prostaglandin E2 (PGE-2), interleukin-6 (IL-6) and cyclooxxgenase-2 (COX-2) release from RAW264.7 cells. The compounds ellagic acid, gallic acid and punicalagin A&B were isolated from EtOAc by high performance liquid chromatography (HPLC) and further identified by mass spectrometry (MS). The inhibitory effect of ellagic acid, gallic acid and punicalagin A&B were evaluated on the production of LPS-induced NO by Griess reagent, PGE-2 and IL-6 by immunoassay kit and prostaglandin E2 competitive ELISA kit, and COX-2 by Western blotting. Ellagic acid, gallic acid and punicalagin A&B potentially inhibited LPS-induced NO, PGE-2 and IL-6 production. The results indicate that ellagic acid, gallic acid and punicalagin may be the compounds responsible for the anti-inflammatory potential of P. granatum.

  4. Micro-cost Analysis of ALK Rearrangement Testing by FISH to Determine Eligibility for Crizotinib Therapy in NSCLC: Implications for Cost Effectiveness of Testing and Treatment.

    PubMed

    Parker, David; Belaud-Rotureau, Marc-Antoine

    2014-01-01

    Break-apart fluorescence in situ hybridization (FISH) is the gold standard test for anaplastic lymphoma kinase (ALK) gene rearrangement. However, this methodology often is assumed to be expensive and potentially cost-prohibitive given the low prevalence of ALK-positive non-small cell lung cancer (NSCLC) cases. To more accurately estimate the cost of ALK testing by FISH, we developed a micro-cost model that accounts for all cost elements of the assay, including laboratory reagents, supplies, capital equipment, technical and pathologist labor, and the acquisition cost of the commercial test and associated reagent kits and controls. By applying a set of real-world base-case parameter values, we determined that the cost of a single ALK break-apart FISH test result is $278.01. Sensitivity analysis on the parameters of batch size, testing efficiency, and the cost of the commercial diagnostic testing products revealed that the cost per result is highly sensitive to batch size, but much less so to efficiency or product cost. This implies that ALK testing by FISH will be most cost effective when performed in high-volume centers. Our results indicate that testing cost may not be the primary determinant of crizotinib (Xalkori(®)) treatment cost effectiveness, and suggest that testing cost is an insufficient reason to limit the use of FISH testing for ALK rearrangement.

  5. Micro-cost Analysis of ALK Rearrangement Testing by FISH to Determine Eligibility for Crizotinib Therapy in NSCLC: Implications for Cost Effectiveness of Testing and Treatment

    PubMed Central

    Parker, David; Belaud-Rotureau, Marc-Antoine

    2014-01-01

    Break-apart fluorescence in situ hybridization (FISH) is the gold standard test for anaplastic lymphoma kinase (ALK) gene rearrangement. However, this methodology often is assumed to be expensive and potentially cost-prohibitive given the low prevalence of ALK-positive non-small cell lung cancer (NSCLC) cases. To more accurately estimate the cost of ALK testing by FISH, we developed a micro-cost model that accounts for all cost elements of the assay, including laboratory reagents, supplies, capital equipment, technical and pathologist labor, and the acquisition cost of the commercial test and associated reagent kits and controls. By applying a set of real-world base-case parameter values, we determined that the cost of a single ALK break-apart FISH test result is $278.01. Sensitivity analysis on the parameters of batch size, testing efficiency, and the cost of the commercial diagnostic testing products revealed that the cost per result is highly sensitive to batch size, but much less so to efficiency or product cost. This implies that ALK testing by FISH will be most cost effective when performed in high-volume centers. Our results indicate that testing cost may not be the primary determinant of crizotinib (Xalkori®) treatment cost effectiveness, and suggest that testing cost is an insufficient reason to limit the use of FISH testing for ALK rearrangement. PMID:25520569

  6. Portland Retail Druggists Association vs Abbott Laboratories et al, part 1.

    PubMed

    Greenberg, R B

    1976-06-01

    The findings of the U.S. Supreme Court, in its March 24, 1976, decision in the case of Portland Retail Druggists vs Abbott Laboratories et al, are presented. The case deals with price differentials offered to nonprofit hospitals by pharmaceutical manufacturers. Historical background leading to the case, and early rulings of a federal district court and a court of appeals, are discussed. The Supreme Court decision appears to reflect favorably on current hospital policies and procedures for drug purchasing and ambulatory care. Issues that require further clarification will be discussed in Part 2.

  7. Analytical performances of a new enzymatic assay for hemoglobin A1c.

    PubMed

    Jaisson, Stéphane; Desmons, Aurore; Renard, Benoît; Chevelle, Benjamin; Leroy, Nathalie; Gillery, Philippe

    2014-07-01

    HbA1c is considered the gold standard for the follow-up of diabetic patients and a new diagnostic tool for diabetes mellitus, which implies the availability of reliable assay methods. We have evaluated a new assay developed by Abbott Laboratories, based on the enzymatic quantification of HbA1c by a fructosyl dipeptide oxidase using Architect analyzers. Precision, linearity, correlation with a HPLC method, accuracy and potential impact interferences on HbA1c measurement have been evaluated. Intra-day and between-day CVs were lower than 1.2% and linearity was excellent from 19 mmol/mol (3.9%) to 163 mmol/mol (17.1%). The results were well correlated with those obtained by the HPLC (Variant II device, kit NU - BioRad): HbA1c [Architect, mmol/mol]=0.986×HbA1c [Variant II, mmol/mol]+0.713 (r=0.998, n=109). This method provided consistent results with IFCC titrated quality control samples. Classical interferences in HbA1c assays (i.e. labile HbA1c, carbamylated hemoglobin, triglycerides or bilirubin) did not have an impact on HbA1c quantification by this method. This new enzymatic assay proved to be a robust and reliable method for HbA1c measurement suitable for routine practice in clinical chemistry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    PubMed

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low HCV concentrations (

  9. New liquid chromatography-tandem mass spectrometry method for routine TDM of vancomycin in patients with both normal and impaired renal functions and comparison with results of polarization fluoroimmunoassay in light of varying creatinine concentrations.

    PubMed

    Brozmanová, Hana; Kacířová, Ivana; Uřinovská, Romana; Šištík, Pavel; Grundmann, Milan

    2017-06-01

    A new LC-MS/MS method with simple sample extraction and a relatively short period of vancomycin analysis for routine therapeutic drug monitoring was developed and validated. 50μL serum was precipitated using 20μL 33% trichloroacetic acid and 0.5mol/L NH 4 OH was added to increase pH before analysis. A RP BEH C18, 1.7μm, 2.1×50mm column maintained at 30°C and tobramycin as internal standard were used. Mass detection was performed in positive electrospray mode. The results obtained with LC-MS/MS method were correlated with an FPIA assay (Abbott AxSYM) using mouse monoclonal antibody. Subjects were divided into three groups according to creatinine levels (53.5±19.1, 150.2±48.4, 471.7±124.7μmol/L) and Passing-Bablok regression analysis and Bland-Altman analysis were used to compare vancomycin concentrations. The results of subjects with both normal and higher creatinine levels correlated very well and the linear regression model equations were near ideal (LC-MS VAN =0.947×Abbott VAN +0.192 and LC-MS VAN =0.973×Abbott VAN -0.411 respectively). Dialyzed patients with the highest creatinine levels showed about 14% greater vancomycin concentration with the FPIA assay (LC-MS VAN =0.866×Abbott VAN +2.127). This overestimation probably due to the presence of the metabolite CDP ought not to be of clinical relevance owing to the wide range of recommended vancomycin concentration. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Generating method-specific Reference Ranges - A harmonious outcome?

    PubMed

    Lee, Graham R; Griffin, Alison; Halton, Kieran; Fitzgibbon, Maria C

    2017-12-01

    When laboratory Reference Ranges (RR) do not reflect analytical methodology, result interpretation can cause misclassification of patients and inappropriate management. This can be mitigated by determining and implementing method-specific RRs, which was the main objective of this study. Serum was obtained from healthy volunteers (Male + Female, n > 120) attending hospital health-check sessions during June and July 2011. Pseudo-anonymised aliquots were stored (at - 70 °C) prior t° analysis on Abbott ARCHITECT c16000 chemistry and i 2000SR immunoassay analysers. Data were stratified by gender where appropriate. Outliers were excluded statistically (Tukey method) to generate non-parametric RRs (2.5th + 97.5th percentiles). RRs were compared to those quoted by Abbott and UK Pathology Harmony (PH) where possible. For 7 selected tests, RRs were verified using a data mining approach. For chemistry tests (n = 23), Upper or Lower Reference Limits (LRL or URL) were > 20% different from Abbott ranges in 25% of tests (11% from PH ranges) but in 38% for immunoassay tests (n = 13). RRs (mmol/L) for sodium (138-144), potassium (3.8-4.9) and chloride (102-110) were considerably narrower than PH ranges (133-146, 3.5-5.0 and 95-108, respectively). The gender difference for ferritin (M: 29-441, F: 8-193 ng/mL) was more pronounced than reported by Abbott (M: 22-275, F: 5-204 ng/mL). Verification studies showed good agreement for chemistry tests (mean [SD] difference = 0.4% [1.2%]) but less so for immunoassay tests (27% [29%]), particularly for TSH (LRL). Where resource permits, we advocate using method-specific RRs in preference to other sources, particularly where method bias and lack of standardisation limits RR transferability and harmonisation.

  11. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

    PubMed

    Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow

    2018-03-01

    Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Utility of the Abbott RealTime HCV Genotype Plus RUO assay used in combination with the Abbott RealTime HCV Genotype II assay.

    PubMed

    He, Chao; Germer, Jeffrey J; Ptacek, Elizabeth R; Bommersbach, Carl E; Mitchell, P Shawn; Yao, Joseph D C

    Hepatitis virus C (HCV) genotype (GT) determination and subtype (ST) differentiation (1a versus 1b) remain important for the selection of appropriate direct-acting antiviral (DAA) therapy. This study is a retrospective comparison of HCV GT and ST result distribution when using the Abbott RealTime HCV Genotype II assay (HCVGT II) alone and in combination with the Abbott RealTime HCV Genotype Plus RUO assay (HCVGT Plus) for routine testing of clinical serum specimens at a reference laboratory. HCVGT II results of specimens tested from June 2014 through January 2016 (period 1) were compared with combined results from HCVGT II and HCVGT Plus (HCVGT II/Plus) performed from January 2016 through January 2017 (period 2). A total of 44,127 and 25,361 specimens were tested during periods 1 and 2, respectively. Use of HCVGT II/Plus significantly reduced the frequency of GT 1 results without ST (0.4%) when compared to preliminary HCVGT II results during period 2 (5.3%; p < 0.01) and final HCVGT II results in period 1 (5.5%; p < 0.01). HCVGT II/Plus also resulted in GT 6 reactivity in 38 specimens with results of "HCV detected" (n = 17) or GT 1 (n = 21) following initial HCVGT II testing during period 2. When compared to the use of HCVGT II alone, HCVGT II/Plus significantly reduced the frequency of GT 1 without ST results observed in a large reference laboratory, while also enabling the identification of HCV GT 6. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Characterization of Samples Identified as Hepatitis C Virus Genotype 1 without Subtype by Abbott RealTime HCV Genotype II Assay Using the New Abbott HCV Genotype Plus RUO Test.

    PubMed

    Mokhtari, Camelia; Ebel, Anne; Reinhardt, Birgit; Merlin, Sandra; Proust, Stéphanie; Roque-Afonso, Anne-Marie

    2016-02-01

    Hepatitis C virus (HCV) genotyping continues to be relevant for therapeutic strategies. Some samples are reported as genotype 1 (gt 1) without subtype by the Abbott RealTime HCV Genotype II (GT II) test. To characterize such samples further, the Abbott HCV Genotype Plus RUO (Plus) assay, which targets the core region for gt 1a, gt 1b, and gt 6 detection, was evaluated as a reflex test in reference to NS5B or 5'-untranslated region (UTR)/core region sequencing. Of 3,626 routine samples, results of gt 1 without subtype were received for 171 samples (4.7%), accounting for 11.5% of gt 1 specimens. The Plus assay and sequencing were applied to 98 of those samples. NS5B or 5'-UTR/core region sequencing was successful for 91/98 specimens (92.9%). Plus assay and sequencing results were concordant for 87.9% of specimens (80/91 samples). Sequencing confirmed Plus assay results for 82.6%, 85.7%, 100%, and 89.3% of gt 1a, gt 1b, gt 6, and non-gt 1a/1b/6 results, respectively. Notably, 12 gt 6 samples that had been identified previously as gt 1 without subtype were assigned correctly here; for 25/28 samples reported as "not detected" by the Plus assay, sequencing identified the samples as gt 1 with subtypes other than 1a/1b. The genetic variability of HCV continues to present challenges for the current genotyping platforms regardless of the applied methodology. Samples identified by the GT II assay as gt 1 without subtype can be further resolved and reliably characterized by the new Plus assay. Copyright © 2016 Mokhtari et al.

  14. Discordances with HIV-1 RNA quantitative determinations by three commercial assays in Pointe Noire, Republic of Congo.

    PubMed

    Bruzzone, Bianca; Bisio, Francesca; Caligiuri, Patrizia; Mboungou, Franc A Mayinda; Nigro, Nicola; Sticchi, Laura; Ventura, Agostina; Saladini, Francesco; Zazzi, Maurizio; Icardi, Giancarlo; Viscoli, Claudio

    2014-07-01

    Accurate HIV-1 RNA quantitation is required to support the scale up of antiretroviral therapy in African countries. Extreme HIV-1 genetic variability in Africa may affect the ability of commercially available assays to detect and quantify HIV-1 RNA accurately. The aim of this study was to compare three real-time PCR assays for quantitation of plasma HIV-1 RNA levels in patients from the Republic of Congo, an area with highly diversified HIV-1 subtypes and recombinants. The Abbott RealTime HIV-1, BioMérieux HIV-1 EasyQ test 1.2 and Cobas AmpliPrep/Cobas TaqMan HIV-1 1.0 were compared for quantitation of HIV-1 RNA in 37 HIV-1 seropositive pregnant women enrolled in the Kento-Mwana project for prevention of mother-to-child transmission in Pointe-Noire, Republic of Congo. The sample panel included a variety of HIV-1 subtypes with as many as 21 (56.8%) putative unique recombinant forms. Qualitative detection of HIV-1 RNA was concordant by all three assays in 33/37 (89.2%) samples. Of the remaining 4 (10.8%) samples, all were positive by Roche, three by Abbott and none by BioMérieux. Differences exceeding 1Log in positive samples were found in 4/31 (12.9%), 10/31 (32.3%) and 5/31 (16.1%) cases between Abbott and BioMérieux, Roche and BioMérieux, and Abbott and Roche, respectively. In this sample panel representative of highly polymorphic HIV-1 in Congo, the agreement among the three assays was moderate in terms of HIV-1 RNA detectability and rather inconsistent in terms of quantitation. Copyright © 2014. Published by Elsevier B.V.

  15. Modification of Antibody Function by Mutagenesis.

    PubMed

    Dasch, James R; Dasch, Amy L

    2017-09-01

    The ability to "fine-tune" recombinant antibodies by mutagenesis separates recombinant antibodies from hybridoma-derived antibodies because the latter are locked with respect to their properties. Recombinant antibodies can be modified to suit the application: Changes in isotype, format (e.g., scFv, Fab, bispecific antibodies), and specificity can be made once the heavy- and light-chain sequences are available. After immunoglobulin heavy and light chains for a particular antibody have been cloned, the binding site-namely, the complementarity determining regions (CDR)-can be manipulated by mutagenesis to obtain antibody variants with improved properties. The method described here is relatively simple, uses commercially available reagents, and is effective. Using the pComb3H vector, a commercial mutagenesis kit, PfuTurbo polymerase (Agilent), and two mutagenic primers, a library of phage with mutagenized heavy and light CDR3 can be obtained. © 2017 Cold Spring Harbor Laboratory Press.

  16. Paradoxical results of two automated real-time PCR assays in the diagnosis of pleural tuberculosis.

    PubMed

    Morales-López, Soraya E; Yepes, Jayr A; Anzola, Irina; Aponte, Hernán; Llerena-Polo, Claudia R

    2017-01-01

    Tuberculosis (TB) is a major cause of worldwide mortality. We report the case of a non-HIV-infected woman with clinical suspicion of pleural tuberculosis and contradictory results between Xpert ® MTB/RIF and Abbott RealTime MTB assays from pleural fluid specimen. Liquid and solid cultures for tuberculosis were performed with negative results. The patient received treatment, and clinical improvement was observed. Both techniques detect Mycobacterium tuberculosis complex, but they have different targets and limits of detection. Abbott RealTime MTB results correlated well with the clinical findings of the patient. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Abbott ARCHITECT iPhenytoin assay versus similar assays for measuring free phenytoin concentrations.

    PubMed

    Tacker, Danyel Hermes; Robinson, Randy; Perrotta, Peter L

    2014-01-01

    To measure free phenytoin (FP) concentrations in filtered specimens using the Abbott ARCHITECT iPhenytoin assay and to compare results from this method with results from the Abbott TDx/FLx assays. We verified accuracy, analytic measurement range, and precision for FP measurements. For correlation and therapeutic interval studies, we used filtered calibrators, controls, proficiency-testing materials, and surplus clinical samples. After implementation, we determined proficiency testing results. The analytic measurement range was 2.0 to 25.0 micromol/L. Quality control materials (6.1, 12.6, and 20.1 micromol/L) provided mean (SD) recoveries of 96.1 (5.0%), 99.2 (5.0%), and 99.3 (5.7%), respectively, and coefficients of variation of 5.2%, 5.0%, and 5.8%, respectively. Clinical specimens produced mean (SD) FP recovery levels of 103.7 (10.6%) (bias, 0.1 [0.3] micromol/L). Altering the FP therapeutic range (4.0-8.0 micromol/L) was unnecessary. Proficiency testing yielded consistently acceptable results. Our accuracy, precision, and correlation results were similar for the TDx/FLx and ARCHITECT assays, which demonstrates that the ARCHITECT iPhenytoin assay is acceptable for clinical FP measurements.

  18. How Abbott’s Fenofibrate Franchise Avoided Generic Competition

    PubMed Central

    Downing, Nicholas S.; Ross, Joseph S.; Jackevicius, Cynthia A.; Krumholz, Harlan M.

    2013-01-01

    The ongoing debate concerning the efficacy of fenofibrate has overshadowed an important aspect of the drug’s history: Abbott, the maker of branded fenofibrate, has produced several bioequivalent reformulations, which dominate the market even though generic fenofibrate has been available for almost a decade. This continued use of branded formulations, which cost twice as much as generic versions of fenofibrate, imposes an annual cost of approximately $700 million on our healthcare system. Abbott maintained its dominance of the fenofibrate market, in part, through a complex switching strategy involving the sequential launch of branded reformulations that had not been shown to be superior to the first generation product and patent litigation that delayed the approval of generic formulations. The small differences in dose of the newer branded formulations prevented substitution with generics of older generation products. As soon as direct generic competition seemed likely at the new dose level where substitution would be allowed, Abbott would launch another reformulation and the cycle would repeat. Our objective, using the fenofibrate example, is to describe how current policy can allow pharmaceutical companies to maintain market share using reformulations of branded medications without demonstrating the superiority of next generation products. PMID:22493409

  19. Diagnostic potential of nested PCR, galactomannan EIA, and beta-D-glucan for invasive aspergillosis in pediatric patients.

    PubMed

    Badiee, Parisa; Alborzi, Abdolvahab; Karimi, Mahammad; Pourabbas, Bahman; Haddadi, Pedram; Mardaneh, Jalal; Moieni, Mahsa

    2012-04-13

    Limited specific data and investigations are available for invasive aspergillosis (IA) in pediatric patients. We evaluated the diagnostic potential of three noninvasive tests including the Platelia Aspergillus EIA kit for using galactomannan antigen, (1,3)-β-D-glucan Detection Reagent Kit, and nested-PCR for Aspergillus DNA in sera. We evaluated the diagnostic potential of three noninvasive tests including EIA for galactomannan antigen  (Platelia Aspergillus), nested  PCR assay for Aspergillus DNA and test for (1→3)-β-D-glucan (Glucatell assay Kit). All pediatric patients treated at the hematology/oncology unit who were at increased risk of developing invasive aspergillosis were enrolled. Clinical samples were examined for Aspergillus infections by mycological methods. Serial blood samples were collected twice weekly and evaluated by noninvasive tests. We analyzed 230 consecutive blood samples from 62 pediatric patients. The incidence rate of invasive aspergillosis in the patients was found to be 27.4%, and the etiologic agents were Aspergillus flavus, Aspergillus fumigatus, and Aspergillus spp.  The sensitivity, specificity, positive and negative predictive values, and likelihood ratios for positive and negative results of galactomannan in patients with proven and probable IA were 90%, 92%, 81.8%, 96%, 11.25, and 0.1; for beta-D-glucan they were 50%, 46%, 26%, 70.6%, 0.9, 0.9; and for nested-PCR they were 80%, 96.2%, 88.9%, 92.6%, 21, and 0.2, respectively. The conventional methods are not able to detect IA, due to the lack of valid and proper sampling. Galactomannan and nested-PCR tests in serum, with enough accuracy and reliability, can serve as noninvasive methods for the detection of IA in pediatric patients. However, the beta-D-glucan test cannot serve as an efficient diagnostic tool in those with hematologic disorders. 

  20. Generation of clinical-grade human induced pluripotent stem cells in Xeno-free conditions.

    PubMed

    Wang, Juan; Hao, Jie; Bai, Donghui; Gu, Qi; Han, Weifang; Wang, Lei; Tan, Yuanqing; Li, Xia; Xue, Ke; Han, Pencheng; Liu, Zhengxin; Jia, Yundan; Wu, Jun; Liu, Lei; Wang, Liu; Li, Wei; Liu, Zhonghua; Zhou, Qi

    2015-11-12

    Human induced pluripotent stem cells (hiPSCs) are considered as one of the most promising seed cell sources in regenerative medicine. Now hiPSC-based clinical trials are underway. To ensure clinical safety, cells used in clinical trials or therapies should be generated under GMP conditions, and with Xeno-free culture media to avoid possible side effects like immune rejection that induced by the Xeno reagents. However, up to now there are no reports for hiPSC lines developed completely under GMP conditions using Xeno-free reagents. Clinical-grade human foreskin fibroblast (HFF) cells used as feeder cells and parental cells of the clinical-grade hiPSCs were isolated from human foreskin tissues and cultured in Xeno-free media. Clinical-grade hiPSCs were derived by integration-free Sendai virus-based reprogramming kit in Xeno-free pluriton™ reprogramming medium or X medium. Neural cells and cardiomyocytes differentiation were conducted following a series of spatial and temporal specific signals induction according to the corresponding lineage development signals. Biological safety evaluation of the clinical-grade HFF cells and hiPSCs were conducted following the guidance of the "Pharmacopoeia of the People's Republic of China, Edition 2010, Volume III". We have successfully derived several integration-free clinical-grade hiPSC lines under GMP-controlled conditions and with Xeno-free reagents culture media in line with the current guidance of international and national evaluation criteria. As for the source of hiPSCs and feeder cells, biological safety evaluation of the HFF cells have been strictly reviewed by the National Institutes for Food and Drug Control (NIFDC). The hiPSC lines are pluripotent and have passed the safety evaluation. Moreover, one of the randomly selected hiPSC lines was capable of differentiating into functional neural cells and cardiomyocytes in Xeno-free culture media. The clinical-grade hiPSC lines therefore could be valuable sources for future hiPSC-based clinical trials or therapies and for drug screening.

  1. [Whole Genome Sequencing of Human mtDNA Based on Ion Torrent PGM™ Platform].

    PubMed

    Cao, Y; Zou, K N; Huang, J P; Ma, K; Ping, Y

    2017-08-01

    To analyze and detect the whole genome sequence of human mitochondrial DNA (mtDNA) by Ion Torrent PGM™ platform and to study the differences of mtDNA sequence in different tissues. Samples were collected from 6 unrelated individuals by forensic postmortem examination, including chest blood, hair, costicartilage, nail, skeletal muscle and oral epithelium. Amplification of whole genome sequence of mtDNA was performed by 4 pairs of primer. Libraries were constructed with Ion Shear™ Plus Reagents kit and Ion Plus Fragment Library kit. Whole genome sequencing of mtDNA was performed using Ion Torrent PGM™ platform. Sanger sequencing was used to determine the heteroplasmy positions and the mutation positions on HVⅠ region. The whole genome sequence of mtDNA from all samples were amplified successfully. Six unrelated individuals belonged to 6 different haplotypes. Different tissues in one individual had heteroplasmy difference. The heteroplasmy positions and the mutation positions on HVⅠ region were verified by Sanger sequencing. After a consistency check by the Kappa method, it was found that the results of mtDNA sequence had a high consistency in different tissues. The testing method used in present study for sequencing the whole genome sequence of human mtDNA can detect the heteroplasmy difference in different tissues, which have good consistency. The results provide guidance for the further applications of mtDNA in forensic science. Copyright© by the Editorial Department of Journal of Forensic Medicine

  2. Development of an improved rapid BACpro® protocol and a method for direct identification from blood-culture-positive bottles using matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Yonezawa, Takatoshi; Watari, Tomohisa; Ashizawa, Kazuho; Hanada, Daisuke; Yanagiya, Takako; Watanabe, Naoki; Terada, Takashi; Tomoda, Yutaka; Fujii, Satoshi

    2018-05-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been incorporated into pathogenic bacterial identification methods and has improved their rapidity. Various methods have been reported to directly identify bacteria with MALDI-TOF MS by pretreating culture medium in blood culture bottles. Rapid BACpro® (Nittobo Medical Co., Ltd.) is a pretreatment kit for effective collection of bacteria with cationic copolymers. However, the Rapid BACpro® pretreatment kit is adapted only for MALDI Biotyper (Bruker Daltonics K.K.), and there has been a desire to expand its use to VITEK MS (VMS; bioMerieux SA). We improved the protocol and made it possible to analyze with VMS. The culture medium bacteria collection method was changed to a method with centrifugation after hemolysis using saponin; the cationic copolymer concentration was changed to 30% of the original concentration; the sequence with which reagents were added was changed; and a change was made to an ethanol/formic acid extraction method. The improved protocol enhanced the identification performance. When VMS was used, the identification rate was 100% with control samples. With clinical samples, the identification agreement rate with the cell smear method was 96.3%. The improved protocol is effective in blood culture rapid identification, being both simpler and having an improved identification performance compared with the original. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. PubMed Central

    Petithory, J. C.; Ambroise-Thomas, P.; De Loye, J.; Pelloux, H.; Goullier-Fleuret, A.; Milgram, M.; Buffard, C.; Garin, J. P.

    1996-01-01

    Reported are the results of a multicentre study involving 40 laboratories that was carried out in France to assess all the currently available methods used for the serodiagnosis of toxoplasmosis. For this purpose 10 batches of control sera were prepared with titres in the range 0-260 IU per ml. These sera were tested in nine laboratories using immunofluorescence methods; in three laboratories using dye tests; in forty laboratories using enzyme-linked immunosorbent assay; in four laboratories using direct agglutination and haemagglutination; in seven laboratories using the high-sensitivity IgG agglutination test; and in three laboratories using the latex agglutination test. In this way, 70 series of titrations were carried out using seven procedures and the results were compared with those obtained using the WHO reference serum in 15 cases, with the French national E6 serum in 16 other cases, and in 39 cases using 15 reference sera supplied by the reagent manufacturers. Rigorous comparison of the tests was not possible in all cases because one aim of the study was to ensure that the tests were carried out under the usual working conditions that prevailed in the participating laboratories. The results obtained indicate that the serological tests currently available for toxoplasmosis are acceptable for its serodiagnosis. Presentation of the titres in IU has advantages; however, caution is required since the definition of IU varies according to the test and reagents used. It is therefore essential that the conditions and limits for a positive reaction be carefully defined in each case, especially for commercially available kits. PMID:8829878

  4. Improvement in diagnostic performance of the revised total testosterone measuring system in Japanese women with polycystic ovary syndrome.

    PubMed

    Niki, Hirobumi; Matsuzaki, Toshiya; Kinouchi, Riyo; Iwasa, Takeshi; Kawami, Takako; Kato, Takeshi; Kuwahara, Akira; Irahara, Minoru

    2014-01-01

    Hyperandrogenemia has become an important factor in the diagnosis of polycystic ovary syndrome (PCOS), in Japan as well as Western countries, since the Japanese PCOS diagnostic criteria were revised in 2007. The revised electrochemiluminescence immunoassay (ECLIA) reagent for total testosterone (T) (ECLusys TESTO II; New T assay), which has lower cross-reactivity with DHEA-S than the previous reagent (ECLusys TESTO I; Old T assay), has recently been developed. We studied the improvement between New and Old T assays in regards to the diagnostic performance of serum T for patients with PCOS. Serum T levels were measured in both normal women (Control, n=92) and PCOS patients (n=86). The rate of elevated T using each kit was significantly higher in the PCOS group than in the Control group, and significantly higher using New T assay (38/86, 44.2%) compared with Old T assay (26/86, 30.2%). A significant correlation was found between T level and body mass index, but not LH level. Furthermore, higher detection rates of hormonal abnormalities were seen in PCOS patients using combined measurement of both T and LH (63/80) compared with single measurement of either T (37/80) or LH (36/80). Therefore, the serum T assay is essential for the diagnosis of PCOS, and New T assay combined with the LH assay may improve the diagnostic process for PCOS. J. Med. Invest. 61: 65-71, February, 2014.

  5. 236. Reconnaissance report photograph, used in the early 1930's of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    236. Reconnaissance report photograph, used in the early 1930's of North Carolina landscape before determination of the roadway alignment. Stanley Abbott realized that maps and plan drawings would mean little to his supervisors who were unfamiliar with the region and chose photographs to communicate route alternatives. On the photo would be a dashed white line to indicate the proposed route. Abbott's written reports included a written description of the region and a suggestion of the acreages necessary to create the parkway, serving as an initiation to field trips with BPR engineers and interior and NPS officials. - Blue Ridge Parkway, Between Shenandoah National Park & Great Smoky Mountains, Asheville, Buncombe County, NC

  6. The Roche Immunoturbidimetric Albumin Method on Cobas c 501 Gives Higher Values Than the Abbott and Roche BCP Methods When Analyzing Patient Plasma Samples.

    PubMed

    Helmersson-Karlqvist, Johanna; Flodin, Mats; Havelka, Aleksandra Mandic; Xu, Xiao Yan; Larsson, Anders

    2016-09-01

    Serum/plasma albumin is an important and widely used laboratory marker and it is important that we measure albumin correctly without bias. We had indications that the immunoturbidimetric method on Cobas c 501 and the bromocresol purple (BCP) method on Architect 16000 differed, so we decided to study these methods more closely. A total of 1,951 patient requests with albumin measured with both the Architect BCP and Cobas immunoturbidimetric methods were extracted from the laboratory system. A comparison with fresh plasma samples was also performed that included immunoturbidimetric and BCP methods on Cobas c 501 and analysis of the international protein calibrator ERM-DA470k/IFCC. The median difference between the Abbott BCP and Roche immunoturbidimetric methods was 3.3 g/l and the Roche method overestimated ERM-DA470k/IFCC by 2.2 g/l. The Roche immunoturbidimetric method gave higher values than the Roche BCP method: y = 1.111x - 0.739, R² = 0.971. The Roche immunoturbidimetric albumin method gives clearly higher values than the Abbott and Roche BCP methods when analyzing fresh patient samples. The differences between the two methods were similar at normal and low albumin levels. © 2016 Wiley Periodicals, Inc.

  7. Development of the Abbott RealTime ZIKA assay for the qualitative detection of Zika virus RNA from serum, plasma, urine, and whole blood specimens using the m2000 system.

    PubMed

    Frankel, Matthew B; Pandya, Kinnari; Gersch, Jeffrey; Siddiqui, Sarah; Schneider, George J

    2017-08-01

    Zika virus is an arthropod-borne flavivirus that has rapidly developed into a world-wide concern. Discovered in 1947, the virus was relatively obscure until an outbreak occurred in 2007 in the Yap islands and spread eventually to the Americas in 2015. Only 20% of patients infected with Zika virus develop symptoms. However, there can be serious consequences of infection including birth defects in developing fetuses and links to Guillain-Barré syndrome. The swift rise in infections has necessitated the development of diagnostic tests for both the detection of viral RNA and the presence of virus-specific antibodies. Abbott has developed a dual target RT-PCR assay for the detection of Zika virus RNA within serum, plasma, whole blood, and urine using the automated m2000 system for sample extraction to result reporting. The Abbott RealTime ZIKA assay has a limit of detection of 30 copies per mL in serum, 40 copies per mL in plasma and urine, and 120 copies per mL in whole blood and demonstrates high specificity against challenges from closely related infectious agents. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Cosmological perturbations in the (1 + 3 + 6)-dimensional space-times

    NASA Astrophysics Data System (ADS)

    Tomita, K.

    2014-12-01

    Cosmological perturbations in the (1+3+6)-dimensional space-times including photon gas without viscous processes are studied on the basis of Abbott et al.'s formalism [R. B. Abbott, B. Bednarz, and S. D. Ellis, Phys. Rev. D 33, 2147 (1986)]. Space-times consist of outer space (the 3-dimensional expanding section) and inner space (the 6-dimensional section). The inner space expands initially and later contracts. Abbott et al. derived only power-type solutions, which appear at the final stage of the space-times, in the small wave-number limit. In this paper, we derive not only small wave-number solutions, but also large wave-number solutions. It is found that the latter solutions depend on the two wave-numbers k_r and k_R (which are defined in the outer and inner spaces, respectively), and that the k_r-dependent and k_R-dependent parts dominate the total perturbations when (k_r/r(t))/(k_R/R(t)) ≫ 1 or ≪ 1, respectively, where r(t) and R(t) are the scale-factors in the outer and inner spaces. By comparing the behaviors of these perturbations, moreover, changes in the spectrum of perturbations in the outer space with time are discussed.

  9. How would GW150914 look with future gravitational wave detector networks?

    NASA Astrophysics Data System (ADS)

    Gaebel, S. M.; Veitch, J.

    2017-09-01

    The first detected gravitational wave signal, GW150914 (Abbott et al 2016 Phys. Rev. Lett. 116 061102), was produced by the coalescence of a stellar-mass binary black hole. Along with the subsequent detection of GW151226, GW170104 and the candidate event LVT151012, this gives us evidence for a population of black hole binaries with component masses in the tens of solar masses (Abbott et al 2016 Phys. Rev. X 6 041015). As detector sensitivity improves, this type of source is expected to make a large contribution to the overall number of detections, but has received little attention compared to binary neutron star systems in studies of projected network performance. We simulate the observation of a system like GW150914 with different proposed network configurations, and study the precision of parameter estimates, particularly source location, orientation and masses. We find that the improvements to low frequency sensitivity that are expected with continued commissioning (Abbott et al 2016 Living Rev. Relativ. 19 1) will improve the precision of chirp mass estimates by an order of magnitude, whereas the improvements in sky location and orientation are driven by the expanded network configuration. This demonstrates that both sensitivity and number of detectors will be important factors in the scientific potential of second generation detector networks.

  10. Hook effect in Abbott i-STAT β-human chorionic gonadotropin (β-hCG) point of care assay.

    PubMed

    Wilgen, Urs; Pretorius, Carel J; Gous, Rehna S; Martin, Cameron; Hale, Vincent J; Ungerer, Jacobus P J

    2014-09-01

    Point-of-care testing for β-hCG has been widely advocated to allow rapid diagnosis/exclusion of pregnancy in the emergency department. A quantitative blood β-hCG assay has the additional benefit of being able to monitor the viability of pregnancy, using serial measurements, to determine the appropriate expected increase in β-hCG levels over time (e.g. ectopic pregnancy), and aiding in determining if an intrauterine gestational sac should be visible on sonographic imaging. Evaluation of the newly released Abbott i-STAT β-hCG point-of-care assay with the Beckman Coulter β-hCG laboratory assay in use. Whole blood, plasma and serum samples with a wide range of β-hCG concentrations were analysed by both methods. The Abbott I-STAT β-hCG compares favourably, can be performed on heparinised whole blood, plasma and serum, and shows acceptable accuracy and precision. However a hook effect at elevated β-hCG was shown in gestational trophoblastic disease as well as normal pregnancies. The i-STAT β-hCG performs acceptably in its intended use in the early detection of pregnancy, but results should always be interpreted within the clinical context, as a hook effect may occur. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  11. Performance of the Abbott RealTime MTB RIF/INH resistance assay when used to test Mycobacterium tuberculosis specimens from Bangladesh.

    PubMed

    Kostera, Joshua; Leckie, Gregor; Abravaya, Klara; Wang, Hong

    2018-01-01

    The Abbott RealTime MTB RIF/INH Resistance Assay (RT MTB RIF/INH) is an assay for the detection of rifampicin (RIF)- and/or isoniazid (INH)-resistant Mycobacterium tuberculosis (MTB). The assay can be used to test sputum, bronchial alveolar lavage, and N-Acetyl-L-Cysteine (NALC)/NaOH pellets prepared from these samples. The assay can be used in direct testing mode, or in reflex mode following a MTB positive result produced by its companion assay, Abbott RT MTB. In this study, the direct testing mode was used to test paired sputum and NALC/NaOH pellets prepared from sputum collected from Bangladesh TB patients. One hundred and thirty two paired samples were tested. The RT MTB RIF/INH inhibition rate was 0%. One hundred and twenty-two paired samples had results above the assay limit of detection and were analyzed by comparing with results from phenotypic drug sensitivity testing, GeneXpert MTB/RIF (Xpert), and MTBDR plus (Hain). RT MTB RIF/INH results were in good agreement with those of GeneXpert and Hain. The ability of this assay to detect RIF and INH resistance may contribute to the global control of multidrug resistant tuberculosis.

  12. Cytology smears as diagnostic material for EGFR gene testing in non-small cell lung cancer.

    PubMed

    Powrózek, Tomasz; Krawczyk, Paweł; Pankowski, Juliusz; Reszka, Katarzyna; Jakubiak, Magdalena; Obrochta, Anna; Wojas-Krawczyk, Kamila; Buczkowski, Jarosław; Milanowski, Janusz

    2015-11-14

    Cytology smears can be effectively used for EGFR mutation testing in the qualification of NSCLC patients for EGFR tyrosine kinase inhibitor therapy. However, tissue specimens are preferred for EGFR mutation analysis. The aim of this study was to estimate the effectiveness of the real-time PCR method for EGFR testing in histology and cytology materials obtained simultaneously from NSCLC patients. Fourteen adenocarcinoma patients with EGFR-mutation-positive primary tumor tissues were included in the study. Corresponding cytological smears of metastatic lymph nodes obtained by EBUS-TBNA were examined. EGFR Mutation Analysis Kit (EntroGen, USA) and real-time PCR (m2000rt system, Abbott, USA) were used for EGFR mutation analysis in both types of material. In primary tumor tissues, 12 deletions in exon 19 and 2 substitutions in exon 21 (L858R mutation) of the EGFR gene were found. Except for 1 deletion in exon 19, the same EGFR gene mutations were detected in all corresponding cytology samples. The percentage of tumor cells, DNA concentration, percentage of mutated DNA as well as ΔCt values were similar in cytology slides and histology material. In both types of materials, no significant correlations were found between the percentage of tumor cells and the percentage of mutated DNA nor between the DNA concentration and the percentage of mutated DNA. We demonstrated the high effectiveness of a sensitive real-time PCR method in EGFR gene mutation detection in cytology smears.

  13. Assessing matrix, interferences and comparability between the Abbott Diagnostics and the Beckman Coulter high-sensitivity cardiac troponin I assays.

    PubMed

    Kavsak, Peter A; Malinowski, Paul; Roy, Chantele; Clark, Lorna; Lamers, Shana

    2018-03-13

    Analytical evaluation of high-sensitivity cardiac troponin (hs-cTn) assays, with particular attention to imprecision, interferences and matrix effects, at normal cTn concentrations, is of utmost importance as many different clinical algorithms use concentration cutoffs <10 ng/L for decision-making. The objective for the present analytical study was to compare the new Beckman Coulter hs-cTnI assay (Access hsTnI) to Abbott's hs-cTnI assay in different matrices and for different interferences, with a focus on concentrations <10 ng/L. The limit of blank (LoB) and the limit of detection (LoD) were determined in different matrices for the Beckman hs-cTnI assay. Passing-Bablok regression and difference plots were determined for 200 matched lithium heparin and EDTA plasma samples for the Beckman assay and 200 lithium heparin samples for the Abbott assay. Both EDTA and heparin plasma samples were also evaluated for stability under refrigerated conditions, for endogenous alkaline phosphatase interference and for hemolysis and icterus. The Beckman hs-cTnI assay LoB was 0.5 ng/L with the following range of LoDs=0.8-1.2 ng/L, with EDTA plasma yielding lower concentrations as compared to lithium heparin plasma (mean difference=-14.9%; 95% CI=-16.9 to 12.9). Below 10 ng/L, lithium heparin cTnI results from the Beckman assay were on average 1.1 ng/L (95% CI=0.7 to 1.5) higher than the Abbott results, with no difference between the methods when using EDTA plasma (mean difference =-0.1 ng/L; 95% CI=-0.3 to 0.2). Low cTnI concentrations were less effected by interferences in EDTA plasma. The Access hsTnI method can reliably detect normal cTnI concentrations with both lithium heparin and EDTA plasma being suitable matrices.

  14. Options to Expand HIV Viral Load Testing in South Africa: Evaluation of the GeneXpert® HIV-1 Viral Load Assay.

    PubMed

    Gous, Natasha; Scott, Lesley; Berrie, Leigh; Stevens, Wendy

    2016-01-01

    Expansion of HIV viral load (VL) testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid) was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert's random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites). Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS) and whole blood, was investigated. Precision, accuracy (agreement) and clinical misclassification (1000cp/ml) of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155) and Abbott HIV-1 RT (n = 145). Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145) and whole blood (n = 147). Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42) and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32-0.37logcp/ml) and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh) and Abbott HIV-1 RT (frozen), respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward) by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument. The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services.

  15. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

    PubMed

    Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L

    2017-07-01

    HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  16. Systematic Review of the Performance of HIV Viral Load Technologies on Plasma Samples

    PubMed Central

    Sollis, Kimberly A.; Smit, Pieter W.; Fiscus, Susan; Ford, Nathan; Vitoria, Marco; Essajee, Shaffiq; Barnett, David; Cheng, Ben; Crowe, Suzanne M.; Denny, Thomas; Landay, Alan; Stevens, Wendy; Habiyambere, Vincent; Perrins, Jos; Peeling, Rosanna W.

    2014-01-01

    Background Viral load (VL) monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring. Methods and Findings A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25), Cobas TaqMan v2.0 (n = 11), Abbott RealTime HIV-1 (n = 23), Versant HIV-1 RNA bDNA 3.0 (n = 15), Versant HIV-1 RNA kPCR 1.0 (n = 2), ExaVir Load v3 (n = 2), and NucliSens EasyQ v2.0 (n = 1). All currently available HIV VL assays are of sufficient sensitivity to detect plasma virus levels at a lower detection limit of 1,000 copies/mL. Bias data comparing the Abbott RealTime HIV-1, TaqMan v2.0 to the Amplicor Monitor v1.5 showed a tendency of the Abbott RealTime HIV-1 to under-estimate results while the TaqMan v2.0 overestimated VL counts. Compared to the Amplicor Monitor v1.5, 2–26% and 9–70% of results from the Versant bDNA 3.0 and Abbott RealTime HIV-1 differed by greater than 0.5log10. The average intra and inter-assay variation of the Abbott RealTime HIV-1 were 2.95% (range 2.0–5.1%) and 5.44% (range 1.17–30.00%) across the range of VL counts (2log10–7log10). Conclusions This review found that all currently available HIV VL assays are of sufficient sensitivity to detect plasma VL of 1,000 copies/mL as a threshold to initiate investigations of treatment adherence or possible treatment failure. Sources of variability between VL assays include differences in technology platform, plasma input volume, and ability to detect HIV-1 subtypes. Monitoring of individual patients should be performed on the same technology platform to ensure appropriate interpretation of changes in VL. Prospero registration # CD42013003603. PMID:24558359

  17. Relaxin concentrations in serum and urine of endangered and crazy mixed-up species.

    PubMed

    Steinetz, B; Lasano, S; de Haas van Dorsser, F; Glickman, S; Bergfelt, D; Santymire, R; Songsassen, N; Swanson, W

    2009-04-01

    The human population explosion has pushed many mammalian wildlife species to the brink of extinction. Conservationists are increasingly turning to captive breeding as a means of preserving the gene pool. We previously reported that serum immunoactive relaxin provided a reliable means of distinguishing between true and pseudopregnancy in domestic dogs, and this method has since been found to be a reliable indicator of true pregnancy in endangered Asian and African elephants and Sumatran rhinoceroses. Our canine relaxin radioimmunoassay (RIA) has now been adapted and validated to measure relaxin in the serum and urine of felids, including domestic and wild species. Moreover, a commercially available canine serum relaxin kit (Witness) Relaxin Kit; Synbiotics, San Diego, CA), has been adapted for reliable detection of relaxin in urine of some felid species. Our porcine relaxin RIA has also been utilized to investigate the role of relaxin in reproductive processes of the spotted hyena, a species in which the female fetuses are severely masculinized in utero. Indeed, this species might well now be extinct were it not for the timely secretion of relaxin to enable copulation and birth of young through the clitoris. Additional studies have suggested relaxin may be a useful marker of pregnancy in the northern fur seal and the maned wolf (the former species has been designated as "depleted" and the latter as "near threatened"). Given appropriate immunoassay reagents, relaxin determination in body fluids thus provides a powerful tool for conservationists and biologists investigating reproduction in a wide variety of endangered and exotic species.

  18. Production and Characterization of Monoclonal Antibody against Recombinant Virus Coat Protein CP42.

    PubMed

    Shibaei, Naeimeh; Majidi, Jafar; Razavi, Khadijeh; Karkhane, Ali Asghar; Sokhandan-Bashir, Nemat; Aghebati-Maleki, Leili

    2017-02-01

    There are many studies related to the production of a ELISA kit for diagnosing virus infections. However, production of most kits depends on purification of whole virus particles, which involves the use of costly equipment and reagents. The purpose of this study was to check out if the anti-CP42 antibodies could be used as a diagnostic assay for detection of Grapevine fanleaf Virus (GFLV). In this study, recombinant GFLV coat protein gene related to selected antigenic determinants was inserted into pET-28a bacterial expression vector and the construct (pET-28a CP42) was cloned into E. coli strain (DE3). Expressed protein was verified with western blotting assay by the use of commercially available anti-GFLV antibody. The recombinant protein was purified using nickel-nitrilotriacetic acid (Ni-NTA) resin. Balb/c mice were immunized with purified protein and splenocytes of hyperimmunized mice were fused with murine myeloma Sp2/0 cells. Positive hybridomas were selected by ELISA using CP42 as coating antigen. The results showed that monoclonal antibody (MAb) specific to CP42 has been successfully generated. Efficiency of produced antibody was analyzed by ELISA and western blotting assay using some confirmed grapevine samples. The infection was confirmed previously based on morphological features and ELISA assay, performed using commercial anti-GFLV antibody. The monoclonal antibody reacted with antigen in ELISA and immunoblot method. Our results demonstrated that anti recombinant CP42 monoclonal antibodies are able to diagnose whole virus in infected grapevine sample using ELISA test.

  19. RNA isolation from bloodstains collected on FTA cards - application in clinical and forensic genetics.

    PubMed

    Skonieczna, Katarzyna; Styczyński, Jan; Krenska, Anna; Wysocki, Mariusz; Jakubowska, Aneta; Grzybowski, Tomasz

    2016-01-01

    Aim of the study: In recent years, RNA analysis has been increasingly used in clinical and forensic genetics. Nevertheless, a major limitation of RNA-based applications is very low RNA stability in biological material, due to the RNAse activity. This highlights the need for improving the methods of RNA collection and storage. Technological approaches such as FTA Classic Cards (Whatman) could provide a solution for the problem of RNA degradation. However, different methods of RNA isolation from FTA cards could have diverse effects on RNA quantity and quality. The purpose of this research was to analyze the utility of three different methods of RNA isolation from peripheral blood collected on FTA Classic Cards (Whatman). The study also aimed at assessing RNA stability in bloodstains deposited on FTA cards. Material and methods: The study was performed on peripheral bloodstains collected from 59 individuals on FTA Classic Cards (Whatman). RNA was isolated with High Pure RNA Isolation Kit (Roche Diagnostics), Universal RNA/miRNA Purification (EURx) and TRIzol Reagent (Life Technologies). RNA was subjected to quantitative analysis followed by reverse transcription and Real - Time PCR reaction. Results: The study has shown that FTA Classic Cards (Whatman) are useful tools for storing bloodstains at room temperature for RNA analysis. Moreover, the method of RNA extraction employing TRIzol Reagent (Life Technologies) provides the highest efficiency and reproducibility for samples stored for no more than 2 years. Conclusions: The FTA cards are suitable for collecting and storing bloodstains for RNA analysis in clinical and forensic genetics.

  20. Circulating Cell-Free DNA Differentiates Severity of Inflammation.

    PubMed

    Frank, Mayu O

    2016-10-01

    As the U.S. population ages, the incidence of chronic disease will rise. Chronic diseases have been linked to chronic inflammation. The purpose of this review is to summarize the literature on cell-free DNA (cfDNA) in relation to inflammation. PubMed, EMBASE, and Web of Science were searched. Inclusion criteria were noninterventional studies on acute and chronic inflammation, autoimmunity, and infection published in English after 2000, conducted in humans using the fluorescence method of quantifying DNA. Of the 442 articles retrieved, 83 were identified for full-text review and 13 remained after application of inclusion criteria. Of the reviewed studies, three involved acute inflammation, six involved chronic inflammation, and four involved infection. Healthy controls with interpretable results were included in six studies, three of which used the Quant-iT high-sensitivity DNA kit and found cfDNA quantities near 800 ng/ml, while the other three used other fluorescence methods and found quantities below 100 ng/ml. All 13 studies compared groups, and all but 1 found statistically significant differences between them. Among studies using the Quant-iT reagent, levels were higher in infection than in chronic inflammation. Among studies that used other reagents, levels increased from chronic to acute inflammation to severe infection. CfDNA levels were associated with mortality and with clinical outcomes in acute inflammation and infection. Most studies assessed cfDNA's correlation with other inflammation biomarkers and found inconclusive results. There appears to be an association between inflammation and cfDNA. Further research is necessary before cfDNA can be used clinically as a measure of inflammation. © The Author(s) 2016.

  1. A novel dynamic flow immunochromatographic test (DFICT) using gold nanoparticles for the serological detection of Toxoplasma gondii infection in dogs and cats.

    PubMed

    Jiang, Wei; Liu, Yingchun; Chen, Yongjun; Yang, Qiufeng; Chun, Peter; Yao, Kailing; Han, Xiangan; Wang, Shaohui; Yu, Shengqing; Liu, Yongjie; Wang, Quan

    2015-10-15

    A novel dynamic flow immunochromatographic test (DFICT) is proposed for rapid assay utilizing Toxoplasma gondii as a model. The test is based on a proprietary technology that combines the principles of immunochromatography and fluid dynamics. Gold nanoparticles conjugated to staphylococcal protein A (SPA) were prepared in liquid form and used as signal vehicles. T. gondii-specific recombinant antigens and SPA were sprayed onto a nitrocellulose membrane in strips at positions designated as T and C, respectively. The DFICT is performed by applying a 100 µL aliquot of liquid gold-SPA conjugate to the reagent hole and a 5 μL aliquot of serum sample to the sample hole. The results were observable within 5 min by the naked eye. The lowest detectable limit of the assay was determined as the highest dilution (1:320) of positive serum. No cross-reaction of the antibodies with other related canine or feline pathogens was observed. The DFICT can be stored for 12 months at 4°C or 6 months with no loss of sensitivity or specificity. A high degree of consistency was observed between the DFICT and the standard ELISA kit, supporting the reliability of the novel test strip. The introduction of a liquid gold nanoparticle conjugate reagent provides this method with several attractive characteristics, such as ease of manufacture, low sample volume requirements, high selectivity and high efficiency. This method opens a novel pathway for rapid diagnostic screening and field analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Performance evaluation of the Abbott CELL-DYN Ruby and the Sysmex XT-2000i haematology analysers.

    PubMed

    Leers, M P G; Goertz, H; Feller, A; Hoffmann, J J M L

    2011-02-01

    Two mid-range haematology analysers (Abbott CELL-DYN Ruby and Sysmex XT-2000i) were evaluated to determine their analytical performance and workflow efficiency in the haematology laboratory. In total 418 samples were processed for determining equivalence of complete blood count (CBC) measurements, and 100 for reticulocyte comparison. Blood smears served for assessing the agreement of the differential counts. Inter-instrument agreement for most parameters was good although small numbers of discrepancies were observed. Systematic biases were found for mean cell volume, reticulocytes, platelets and mean platelet volume. CELL-DYN Ruby WBC differentials were obtained with all samples while the XT-2000i suppressed differentials partially or completely in 13 samples (3.1%). WBC subpopulation counts were otherwise in good agreement with no major outliers. Following first-pass CBC/differential analysis, 88 (21%) of XT-2000i samples required further analyser processing compared to 18 (4.3%) for the CELL-DYN Ruby. Smear referrals for suspected WBC/nucleated red blood cells and platelet abnormalities were indicated for 106 (25.4%) and 95 (22.7%) of the XT-2000i and CELL-DYN Ruby samples respectively. Flagging efficiencies for both analysers were found to be similar. The Sysmex XT-2000i and Abbott CELL-DYN Ruby analysers have broadly comparable analytical performance, but the CELL-DYN Ruby showed superior first-pass efficiency. © 2010 Blackwell Publishing Ltd.

  3. Detection of antibodies to hepatitis B core antigen using the Abbott ARCHITECT anti-HBc assay: analysis of borderline reactive sera.

    PubMed

    Ollier, Laurence; Laffont, Catherine; Kechkekian, Aurore; Doglio, Alain; Giordanengo, Valérie

    2008-12-01

    Routine use of the automated chemiluminescent microparticle immunoassay Abbott ARCHITECT anti-HBc for diagnosis of hepatitis B is limited in case of borderline reactive sera with low signal close to the cut-off index. In order to determine the significance of anti-HBc detection when borderline reactivity occurs using the ARCHITECT anti-HBc assay, a comparative study was designed. 3540 serum samples collected over a 2-month period in the hospital of Nice were examined for markers of HBV infection (HBsAg, anti-HBs and anti-HBc). One hundred seven samples with sufficient volume and with borderline reactivity by the ARCHITECT assay were tested by two other anti-HBc assays, a microparticle enzyme immunoassay (MEIA, AxSYM Core, Abbott Laboratories, IL, USA) and an enzyme linked fluorescent assay (ELFA, VIDAS Anti-HBc Total II, bioMérieux, Lyon, France). Only 46 samples were confirmed by the AxSYM and the VIDAS assays. Additional serological information linked to patient history showed that the remaining samples (61) were false positives (11), had low titer of anti-HBc antibodies (13), or were inconclusive (37). This comparative study highlighted the existence of a grey zone around the cut-off index. Confirmative results through a different immunoassay are needed to confirm the diagnosis of HBV on borderline reactive sera using the ARCHITECT anti-HBc assay.

  4. Comparison of BioStar Strep A OIA optical immune assay, Abbott TestPack Plus Strep A, and culture with selective media for diagnosis of group A streptococcal pharyngitis.

    PubMed Central

    Roe, M; Kishiyama, C; Davidson, K; Schaefer, L; Todd, J

    1995-01-01

    We directly compared three techniques for the diagnosis of group A streptococcal pharyngitis in 500 symptomatic children seen in the Emergency Department or Child Care Clinic of The Children's Hospital of Denver. Throats were vigorously swabbed with two rayon swabs, which were transported immediately to the Microbiology Laboratory. Each swab was cultured aerobically on Strep A Isolation Agar (Remel) and then tested for antigen-one swab by the Strep A OIA optical immune assay (BioStar) and the other by the TestPack Plus Strep A (Abbott) technique. Each test was performed blind to the others. The refrigerated pledget was cultured in Todd-Hewitt broth if an antigen test was positive and both direct plate cultures were negative (the "gold standard" was any culture positive). All isolates were serologically grouped. Of 500 complete patient cultures, 151 (30%) were positive for group A streptococcal growth. The two antigen tests gave comparable results with an average sensitivity of 83%. Each was significantly (P < 0.02) less sensitive than its corresponding culture. The BioStar Strep A OIA optical immune assay produced significantly (P < 0.003) more false-positive results than did the Abbott test. Rapid antigen testing is not sensitive enough to eliminate the need for backup cultures. PMID:7650184

  5. Simultaneous analysis of cerebrospinal fluid biomarkers using microsphere-based xMAP multiplex technology for early detection of Alzheimer's disease.

    PubMed

    Kang, Ju-Hee; Vanderstichele, Hugo; Trojanowski, John Q; Shaw, Leslie M

    2012-04-01

    The xMAP-Luminex multiplex platform for measurement of Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers using Innogenetics AlzBio3 immunoassay reagents that are for research use only has been shown to be an effective tool for early detection of an AD-like biomarker signature based on concentrations of CSF Aβ(1-42), t-tau and p-tau(181). Among the several advantages of the xMAP-Luminex platform for AD CSF biomarkers are: a wide dynamic range of ready-to-use calibrators, time savings for the simultaneous analyses of three biomarkers in one analytical run, reduction of human error, potential of reduced cost of reagents, and a modest reduction of sample volume as compared to conventional enzyme-linked immunosorbant assay (ELISA) methodology. Recent clinical studies support the use of CSF Aβ(1-42), t-tau and p-tau(181) measurement using the xMAP-Luminex platform for the early detection of AD pathology in cognitively normal individuals, and for prediction of progression to AD dementia in subjects with mild cognitive impairment (MCI). Studies that have shown the prediction of risk for progression to AD dementia by MCI patients provide the basis for the use of CSF Aβ(1-42), t-tau and p-tau(181) testing to assign risk for progression in patients enrolled in therapeutic trials. Furthermore emerging study data suggest that these pathologic changes occur in cognitively normal subjects 20 or more years before the onset of clinically detectable memory changes thus providing an objective measurement for use in the assessment of treatment effects in primary treatment trials. However, numerous previous ELISA and Luminex-based multiplex studies reported a wide range of absolute values of CSF Aβ(1-42), t-tau and p-tau(181) indicative of substantial inter-laboratory variability as well as varying degrees of intra-laboratory imprecision. In order to address these issues a recent inter-laboratory investigation that included a common set of CSF pool aliquots from controls as well as AD patients over a range of normal and pathological Aβ(1-42), t-tau and p-tau(181) values as well as agreed-on standard operating procedures (SOPs) assessed the reproducibility of the multiplex methodology and Innogenetics AlzBio3 immunoassay reagents. This study showed within-center precision values of 5% to a little more than 10% and good inter-laboratory %CV values (10-20%). There are several likely factors influencing the variability of CSF Aβ(1-42), t-tau and p-tau(181) measurements. In this review, we describe the pre-analytical, analytical and post-analytical sources of variability including sources inherent to kits, and describe procedures to decrease the variability. A CSF AD biomarker Quality Control program has been established and funded by the Alzheimer Association, and global efforts are underway to further define optimal pre-analytical SOPs and best practices for the methodologies available or in development including plans for production of a standard reference material that could provide for a common standard against which manufacturers of immunoassay kits would assign calibration standard values. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. 3D plasmonic nanobowl platform for the study of exosomes in solution

    NASA Astrophysics Data System (ADS)

    Lee, Changwon; Carney, Randy P.; Hazari, Sidhartha; Smith, Zachary J.; Knudson, Alisha; Robertson, Christopher S.; Lam, Kit S.; Wachsmann-Hogiu, Sebastian

    2015-05-01

    Thin silver film coated nanobowl Surface Enhanced Raman Spectroscopy (SERS) substrates are used to capture exosomes in solution for SERS measurements that can provide biochemical analysis of intact and ruptured exosomes. Exosomes derived via Total Exosome Isolation Reagent (TEIR) as well as ultracentrifugation (UC) from the SKOV3 cell line were analyzed. Spectra of exosomes derived via TEIR are dominated by a signal characteristic for the TEIR kit that needs to be subtracted for all measurements. Differences in SERS spectra recorded at different times during the drying of the exosome solution are statistically analyzed with Principal Component Analysis (PCA). At the beginning of the drying process, SERS spectra of exosomes exhibit peaks characteristic for both lipids and proteins. Later on during the drying process, new SERS peaks develop, suggesting that the initially intact exosome ruptures over time. This time-dependent evolution of SERS peaks enables analysis of exosomal membrane contents and the contents inside the exosomes.

  7. A morphological method for ammonia detection in liver

    PubMed Central

    Gutiérrez-de-Juan, Virginia; López de Davalillo, Sergio; Fernández-Ramos, David; Barbier-Torres, Lucía; Zubiete-Franco, Imanol; Fernández-Tussy, Pablo; Simon, Jorge; Lopitz-Otsoa, Fernando; de las Heras, Javier; Iruzubieta, Paula; Arias-Loste, María Teresa; Villa, Erica; Crespo, Javier; Andrade, Raúl; Lucena, M. Isabel; Varela-Rey, Marta; Lu, Shelly C.; Mato, José M.; Delgado, Teresa Cardoso

    2017-01-01

    Hyperammonemia is a metabolic condition characterized by elevated levels of ammonia and a common event in acute liver injury/failure and chronic liver disease. Even though hepatic ammonia levels are potential predictive factors of patient outcome, easy and inexpensive methods aiming at the detection of liver ammonia accumulation in the clinical setting remain unavailable. Thus, herein we have developed a morphological method, based on the utilization of Nessler´s reagent, to accurately and precisely detect the accumulation of ammonia in biological tissue. We have validated our method against a commercially available kit in mouse tissue samples and, by using this modified method, we have confirmed the hepatic accumulation of ammonia in clinical and animal models of acute and chronic advanced liver injury as well as in the progression of fatty liver disease. Overall, we propose a morphological method for ammonia detection in liver that correlates well with the degree of liver disease severity and therefore can be potentially used to predict patient outcome. PMID:28319158

  8. Comparison of three methods of DNA extraction from peripheral blood mononuclear cells and lung fragments of equines.

    PubMed

    Santos, E M; Paula, J F R; Motta, P M C; Heinemann, M B; Leite, R C; Haddad, J P A; Del Puerto, H L; Reis, J K P

    2010-08-17

    We compared three different protocols for DNA extraction from horse peripheral blood mononuclear cells (PBMC) and lung fragments, determining average final DNA concentration, purity, percentage of PCR amplification using beta-actin, and cost. Thirty-four samples from PBMC, and 33 samples from lung fragments were submitted to DNA extraction by three different protocols. Protocol A consisted of a phenol-chloroform and isoamylic alcohol extraction, Protocol B used alkaline extraction with NaOH, and Protocol C used the DNAzol((R)) reagent kit. Protocol A was the best option for DNA extraction from lung fragments, producing high DNA concentrations, with high sensitivity in PCR amplification (100%), followed by Protocols C and B. On the other hand, for PBMC samples, Protocol B gave the highest sensitivity in PCR amplification (100%), followed by Protocols C and A. We conclude that Protocol A should be used for PCR diagnosis from lung fragment samples, while Protocol B should be used for PBMC.

  9. Microfluidic system for the identification of bacterial pathogens causing urinary tract infections

    NASA Astrophysics Data System (ADS)

    Becker, Holger; Hlawatsch, Nadine; Haraldsson, Tommy; van der Wijngaart, Wouter; Lind, Anders; Malhotra-Kumar, Surbi; Turlej-Rogacka, Agata; Goossens, Herman

    2015-03-01

    Urinary tract infections (UTIs) are among the most common bacterial infections and pose a significant healthcare burden. The growing trend in antibiotic resistance makes it mandatory to develop diagnostic kits which allow not only the determination of a pathogen but also the antibiotic resistances. We have developed a microfluidic cartridge which takes a direct urine sample, extracts the DNA, performs an amplification using batch-PCR and flows the sample over a microarray which is printed into a microchannel for fluorescence detection. The cartridge is injection-molded out of COP and contains a set of two-component injection-molded rotary valves to switch between input and to isolate the PCR chamber during thermocycling. The hybridization probes were spotted directly onto a functionalized section of the outlet microchannel. We have been able to successfully perform PCR of E.coli in urine in this chip and perform a fluorescence detection of PCR products. An upgraded design of the cartridge contains the buffers and reagents in blisters stored on the chip.

  10. Smartphone-based assessment of blood alteration severity

    NASA Astrophysics Data System (ADS)

    Li, Xianglin; Xue, Jiaxin; Li, Wei; Li, Ting

    2018-02-01

    Blood quality and safety management is a critical issue for cold chain transportation of blood or blood-based biological reagent. The conventional methods of blood alteration severity assessment mainly rely on kit test or blood-gas analysis required opening the blood package to get samples, which cause possible blood pollution and are complicate, timeconsuming, and expensive. Here we proposed to develop a portable, real-time, safety, easy-operated and low cost method aimed at assessing blood alteration severity. Color images of the blood in transparent blood bags were collected with a smartphone and the alteration severity of the blood was assessed by the smartphone app offered analysis of RGB color values of the blood. The algorithm is based on a large number sample of RGB values of blood at different alteration degree. The blood quality results evaluated by the smartphone are in accordance with the actual data. This study indicates the potential of smart phone in real time, convenient, and reliable blood quality assessment.

  11. A Fast Solution to NGS Library Prep with Low Nanogram DNA Input

    PubMed Central

    Liu, Pingfang; Lohman, Gregory J.S.; Cantor, Eric; Langhorst, Bradley W.; Yigit, Erbay; Apone, Lynne M.; Munafo, Daniela B.; Stewart, Fiona J.; Evans, Thomas C.; Nichols, Nicole; Dimalanta, Eileen T.; Davis, Theodore B.; Sumner, Christine

    2013-01-01

    Next Generation Sequencing (NGS) has significantly impacted human genetics, enabling a comprehensive characterization of the human genome as well as a better understanding of many genomic abnormalities. By delivering massive DNA sequences at unprecedented speed and cost, NGS promises to make personalized medicine a reality in the foreseeable future. To date, library construction with clinical samples has been a challenge, primarily due to the limited quantities of sample DNA available. Our objective here was to overcome this challenge by developing NEBNext® Ultra DNA Library Prep Kit, a fast library preparation method. Specifically, we streamlined the workflow utilizing novel NEBNext reagents and adaptors, including a new DNA polymerase that has been optimized to minimize GC bias. As a result of this work, we have developed a simple method for library construction from an amount of DNA as low as 5 ng, which can be used for both intact and fragmented DNA. Moreover, the workflow is compatible with multiple NGS platforms.

  12. Quantitative electrochemical metalloimmunoassay for TFF3 in urine using a paper analytical device.

    PubMed

    DeGregory, Paul R; Tsai, Yi-Ju; Scida, Karen; Richards, Ian; Crooks, Richard M

    2016-03-07

    We report a paper-based assay platform for the detection of the kidney disease marker Trefoil Factor 3 (TFF3) in human urine. The sensor is based on a quantitative metalloimmunoassay that can determine TFF3 concentrations via electrochemical detection of environmentally stable silver nanoparticle (AgNP) labels attached to magnetic microbeads via a TFF3 immunosandwich. The paper electroanalytical device incorporates two preconcentration steps that make it possible to detect concentrations of TFF3 in human urine at the low end of the target TFF3 concentration range (0.03-7.0 μg mL(-1)). Importantly, the paper device provides a level of accuracy for TFF3 determination in human urine equivalent to that of a commercial kit. The paper sensor has a dynamic range of ∼2.5 orders of magnitude, only requires a simple, one-step incubation protocol, and is fast, requiring only 10 min to complete. The cost of the materials at the prototypic laboratory scale, excluding reagents, is just US$0.42.

  13. A morphological method for ammonia detection in liver.

    PubMed

    Gutiérrez-de-Juan, Virginia; López de Davalillo, Sergio; Fernández-Ramos, David; Barbier-Torres, Lucía; Zubiete-Franco, Imanol; Fernández-Tussy, Pablo; Simon, Jorge; Lopitz-Otsoa, Fernando; de Las Heras, Javier; Iruzubieta, Paula; Arias-Loste, María Teresa; Villa, Erica; Crespo, Javier; Andrade, Raúl; Lucena, M Isabel; Varela-Rey, Marta; Lu, Shelly C; Mato, José M; Delgado, Teresa Cardoso; Martínez-Chantar, María-Luz

    2017-01-01

    Hyperammonemia is a metabolic condition characterized by elevated levels of ammonia and a common event in acute liver injury/failure and chronic liver disease. Even though hepatic ammonia levels are potential predictive factors of patient outcome, easy and inexpensive methods aiming at the detection of liver ammonia accumulation in the clinical setting remain unavailable. Thus, herein we have developed a morphological method, based on the utilization of Nessler´s reagent, to accurately and precisely detect the accumulation of ammonia in biological tissue. We have validated our method against a commercially available kit in mouse tissue samples and, by using this modified method, we have confirmed the hepatic accumulation of ammonia in clinical and animal models of acute and chronic advanced liver injury as well as in the progression of fatty liver disease. Overall, we propose a morphological method for ammonia detection in liver that correlates well with the degree of liver disease severity and therefore can be potentially used to predict patient outcome.

  14. Comparison of an assay using signal amplification of the heat-dissociated p24 antigen with the Roche Monitor human immunodeficiency virus RNA assay.

    PubMed

    Pascual, Alvaro; Cachafeiro, Ada; Funk, Michele L; Fiscus, Susan A

    2002-07-01

    We compared an assay using signal amplification of a heat-dissociated p24 antigen (HDAg) with the Roche Monitor human immunodeficiency virus (HIV) RNA assay. The two assays gave comparable results when 130 specimens from 130 patients were tested (r = 0.60, P < 0.0001). The HDAg assay was almost as sensitive (85%) as the Roche HIV RNA kit (95%), just as specific (25 negative results from 25 HIV seronegative volunteers [100%]), less variable (mean log standard deviation of 0.07 compared to 0.11 when eight specimens were tested three or four times), and less expensive (reagent and labor costs, $8 versus $75). The assay appeared to be useful for monitoring established patients (n = 17) and identifying seroconverters (n = 4). HIV subtypes A to F were all recognized. This assay should be useful for monitoring patients in resource-poor countries and for monitoring vaccine recipients.

  15. ELIXYS - a fully automated, three-reactor high-pressure radiosynthesizer for development and routine production of diverse PET tracers

    PubMed Central

    2013-01-01

    Background Automated radiosynthesizers are vital for routine production of positron-emission tomography tracers to minimize radiation exposure to operators and to ensure reproducible synthesis yields. The recent trend in the synthesizer industry towards the use of disposable kits aims to simplify setup and operation for the user, but often introduces several limitations related to temperature and chemical compatibility, thus requiring reoptimization of protocols developed on non-cassette-based systems. Radiochemists would benefit from a single hybrid system that provides tremendous flexibility for development and optimization of reaction conditions while also providing a pathway to simple, cassette-based production of diverse tracers. Methods We have designed, built, and tested an automated three-reactor radiosynthesizer (ELIXYS) to provide a flexible radiosynthesis platform suitable for both tracer development and routine production. The synthesizer is capable of performing high-pressure and high-temperature reactions by eliminating permanent tubing and valve connections to the reaction vessel. Each of the three movable reactors can seal against different locations on disposable cassettes to carry out different functions such as sealed reactions, evaporations, and reagent addition. A reagent and gas handling robot moves sealed reagent vials from storage locations in the cassette to addition positions and also dynamically provides vacuum and inert gas to ports on the cassette. The software integrates these automated features into chemistry unit operations (e.g., React, Evaporate, Add) to intuitively create synthesis protocols. 2-Deoxy-2-[18F]fluoro-5-methyl-β-l-arabinofuranosyluracil (l-[18F]FMAU) and 2-deoxy-2-[18F]fluoro-β-d-arabinofuranosylcytosine (d-[18F]FAC) were synthesized to validate the system. Results l-[18F]FMAU and d-[18F]FAC were successfully synthesized in 165 and 170 min, respectively, with decay-corrected radiochemical yields of 46% ± 1% (n = 6) and 31% ± 5% (n = 6), respectively. The yield, repeatability, and synthesis time are comparable to, or better than, other reports. d-[18F]FAC produced by ELIXYS and another manually operated apparatus exhibited similar biodistribution in wild-type mice. Conclusion The ELIXYS automated radiosynthesizer is capable of performing radiosyntheses requiring demanding conditions: up to three reaction vessels, high temperatures, high pressures, and sensitive reagents. Such flexibility facilitates tracer development and the ability to synthesize multiple tracers on the same system without customization or replumbing. The disposable cassette approach simplifies the transition from development to production. PMID:23849185

  16. The children's republic of science in the antebellum literature of Samuel Griswold Goodrich and Jacob Abbott.

    PubMed

    Pandora, Katherine

    2009-01-01

    The antebellum years in the United States were marked by vigorous debates about national identity in which issues of hierarchy, authority, and democratic values came under intense scrutiny. During this period, a prime objective of indigenous authors writing for American children was educating the young so they would be ready to assume their republican responsibilities. The question of how depictions and discussions about nature and science were deployed toward this end is explored by examining key texts about nature and science from the era's two most prolific and popular children's authors--Samuel Griswold Goodrich (1793-1860) and Jacob Abbott (1803-79)--and highlighting assumptions within these works about what the proper relationship should be between the search for scientific knowledge and the larger polity.

  17. Sensitive and less invasive confirmatory diagnosis of visceral leishmaniasis in Sudan using loop-mediated isothermal amplification (LAMP)

    PubMed Central

    Mukhtar, Maowia; Ali, Sababil S.; Boshara, Salah A.; Albertini, Audrey; Monnerat, Séverine; Bessell, Paul; Mori, Yasuyoshi; Kubota, Yutaka; Ndung’u, Joseph M.

    2018-01-01

    Background Confirmatory diagnosis of visceral leishmaniasis (VL), as well as diagnosis of relapses and test of cure, usually requires examination by microscopy of samples collected by invasive means, such as splenic, bone marrow or lymph node aspirates. This causes discomfort to patients, with risks of bleeding and iatrogenic infections, and requires technical expertise. Molecular tests have great potential for diagnosis of VL using peripheral blood, but require well-equipped facilities and trained personnel. More user-friendly, and field-amenable options are therefore needed. One method that could meet these requirements is loop-mediated isothermal amplification (LAMP) using the Loopamp Leishmania Detection Kit, which comes as dried down reagents that can be stored at room temperature, and allows simple visualization of results. Methodology/Principal findings The Loopamp Leishmania Detection Kit (Eiken Chemical Co., Japan), was evaluated in the diagnosis of VL in Sudan. A total of 198 VL suspects were tested by microscopy of lymph node aspirates (the reference test), direct agglutination test-DAT (in house production) and rK28 antigen-based rapid diagnostic test (OnSite Leishmania rK39-Plus, CTK Biotech, USA). LAMP was performed on peripheral blood (whole blood and buffy coat) previously processed by: i) a direct boil and spin method, and ii) the QIAamp DNA Mini Kit (QIAgen). Ninety seven of the VL suspects were confirmed as cases by microscopy of lymph node aspirates. The sensitivity and specificity for each of the tests were: rK28 RDT 98.81% and 100%; DAT 88.10% and 78.22%; LAMP-boil and spin 97.65% and 99.01%; LAMP-QIAgen 100% and 99.01%. Conclusions/Significance Due to its simplicity and high sensitivity, rK28 RDT can be used first in the diagnostic algorithm for primary VL diagnosis, the excellent performance of LAMP using peripheral blood indicates that it can be also included in the algorithm for diagnosis of VL as a simple test when parasitological confirmatory diagnosis is required in settings that are lower than the reference laboratory, avoiding the need for invasive lymph node aspiration. PMID:29444079

  18. Options to Expand HIV Viral Load Testing in South Africa: Evaluation of the GeneXpert® HIV-1 Viral Load Assay

    PubMed Central

    Gous, Natasha; Scott, Lesley; Berrie, Leigh; Stevens, Wendy

    2016-01-01

    Background Expansion of HIV viral load (VL) testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid) was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert’s random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites). Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS) and whole blood, was investigated. Method Precision, accuracy (agreement) and clinical misclassification (1000cp/ml) of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155) and Abbott HIV-1 RT (n = 145). Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145) and whole blood (n = 147). Results Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42) and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32–0.37logcp/ml) and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh) and Abbott HIV-1 RT (frozen), respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward) by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument. Conclusion The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services. PMID:27992495

  19. Study on hepatitis B virus (HBV) infection and hepatitis B virus carrier state in children at two Mobil Oil Indonesia locations in Indonesia.

    PubMed

    Lubis, C P; Judin, A

    1990-01-01

    Between May and July 1985, a cross-sectional study on hepatitis B virus (HBV) infection and hepatitis B virus carrier state was conducted in children at two locations of Mobil Oil Indonesia i.e. Jakarta and Medan. Two main groups of Mobil Oil Indonesia population namely "employees" and "dependents" were also included in this study. From each subject, 10 ml of venous blood was taken and the sera separated and kept in a freezer at the temperature of -20 degrees C before sending them to the laboratories and tested with reagents produced by the Abbott Laboratory for HBsAg, anti-HBs and anti-HBc by radioimmunoassay (AUSRIA II-125, AVSAB and CORAB respectively). The test of blood samples from Jakarta population was done by the "the PRODIA LABORATORY" in Jakarta, while the test of blood samples from Medan was conducted by "the PATH LABORATORY" in Singapore which is nearer from Medan than Jakarta. The result of HBV markers test from 197 children were as follows: Incubation period of carrier state (HBsAg+) 1%; acute hepatitis B or persistent carrier state (HBsAg + and anti-HBc +) 0.5%; recovery/immune (anti-HBs + and anti-HBc +) 3.5%; immunization without infection or recovery with loss of detectable anti-HBc (anti-HBs +) 2% and acute hepatitis B (Window period) or recovery with loss of detectable antiHBs (anti-HBc +) 5%. The conclusion is that hepatitis B virus infection in a low percentage was found in children of Mobil Oil Indonesia population.

  20. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...

  1. 76 FR 4283 - Foreign-Trade Zone 153-San Diego, CA; Application for Manufacturing Authority; Abbott...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-25

    ..., Murrieta. The facilities are used for the production of cardiovascular devices including stents, catheters... finished product) include: resins, plastic tubing, stent components, plastic packaging, plastic clips...

  2. Abbott, Francis (1799-1883)

    NASA Astrophysics Data System (ADS)

    Murdin, P.

    2000-11-01

    Watchmaker, born in Derby, England, convict, transported to Tasmania in 1845. He made astronomical observations at the Rossbank Observatory after the end of his sentence until its closure in 1854 and in his private laboratory in Hobart....

  3. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Applicability. Chemical kits and first aid kits... assigned to the chemical kit and first aid kit as a whole must be the most stringent packing group assigned...

  4. HCV-RNA quantification in liver bioptic samples and extrahepatic compartments, using the abbott RealTime HCV assay.

    PubMed

    Antonucci, FrancescoPaolo; Cento, Valeria; Sorbo, Maria Chiara; Manuelli, Matteo Ciancio; Lenci, Ilaria; Sforza, Daniele; Di Carlo, Domenico; Milana, Martina; Manzia, Tommaso Maria; Angelico, Mario; Tisone, Giuseppe; Perno, Carlo Federico; Ceccherini-Silberstein, Francesca

    2017-08-01

    We evaluated the performance of a rapid method to quantify HCV-RNA in the hepatic and extrahepatic compartments, by using for the first time the Abbott RealTime HCV-assay. Non-tumoral (NT), tumoral (TT) liver samples, lymph nodes and ascitic fluid from patients undergoing orthotopic-liver-transplantation (N=18) or liver resection (N=4) were used for the HCV-RNA quantification; 5/22 patients were tested after or during direct acting antivirals (DAA) treatment. Total RNA and DNA quantification from tissue-biopsies allowed normalization of HCV-RNA concentrations in IU/μg of total RNA and IU/10 6 liver-cells, respectively. HCV-RNA was successfully quantified with high reliability in liver biopsies, lymph nodes and ascitic fluid samples. Among the 17 untreated patients, a positive and significant HCV-RNA correlation between serum and NT liver-samples was observed (Pearson: rho=0.544, p=0.024). Three DAA-treated patients were HCV-RNA "undetectable" in serum, but still "detectable" in all tested liver-tissues. Differently, only one DAA-treated patient, tested after sustained-virological-response, showed HCV-RNA "undetectability" in liver-tissue. HCV-RNA was successfully quantified with high reliability in liver bioptic samples and extrahepatic compartments, even when HCV-RNA was "undetectable" in serum. Abbott RealTime HCV-assay is a good diagnostic tool for HCV quantification in intra- and extra-hepatic compartments, whenever a bioptic sample is available. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Lack of cross-reactivity of Ambien (zolpidem) with drugs in standard urine drug screens.

    PubMed

    Piergies, A A; Sainati, S; Roth-Schechter, B

    1997-04-01

    To determine in healthy volunteers (men and women; 18 to 40 years old) the potential cross-reactivity of Ambien (zolpidem) and/or its metabolites with drugs that are screened by the Syva EMIT II and the Abbott ADx urine drug screens assays. Open-label, fixed-treatment sequence of 1 night each of treatment with zolpidem (10 mg) and temazepam (15 mg). Clinical Pharmacology Unit within a teaching hospital. Over a 24-hour period, presence or absence of positive results on the Syva EMIT II or the Abbott ADx urine drug assay system, each performed at two different laboratory assay sites. Following ingestion of zolpidem, no subject had any positive response in either laboratory to the Syva EMIT II or the Abbott ADx urine drug screen assays at 0, 4, 8, 12, and 24 hours postdose. During the same time period, all subjects had measurable zolpidem plasma concentrations at 1.5 and 8 hours postdose, with mean concentrations of 115.2 ng/mL and 30.1 ng/mL, respectively (in agreement with its half-life of 2.5 hours). The positive response rate at 10 hours after ingestion of Restoril (temazepam) among the four laboratory/assay combinations ranged from 36.8% to 73.7%, a range that is within the reported response rates for these tests. These data indicate that zolpidem will not cross-react in standard urine drug screens with benzodiazepines, opiates, barbiturates, cocaine, cannabinoids, or amphetamines.

  6. Measure of viral load by using the Abbott Real-Time HIV-1 assay on dried blood and plasma spot specimens collected in 2 rural dispensaries in Cameroon.

    PubMed

    Mbida, André Dieudonné; Sosso, Samuel; Flori, Pierre; Saoudin, Henia; Lawrence, Philip; Monny-Lobé, Marcel; Oyono, Yves; Ndzi, Edward; Cappelli, Giulia; Lucht, Frédéric; Pozzetto, Bruno; Oukem-Boyer, Odile Ouwe Missi; Bourlet, Thomas

    2009-09-01

    This study aimed to evaluate the use of dried blood spots (DBSs) and dried plasma spots (DPSs) locally collected in 2 rural dispensaries in Cameroon for the quantification of HIV-1 RNA. Forty-one subjects were sampled and spots of whole blood and plasma were deposited onto Whatman 903 cards and dried at ambient temperature under local conditions. Two sets of DBS and DPS cards were done per patient. The rest of the liquid plasma (LP) was frozen until use. LPs were tested at the "Chantal Biya" International Reference Centre (Yaoundé, Cameroon) by the Abbott Real-Time HIV-1 assay (Abbott Molecular Diagnostics, Wiesbaden, Germany). One series of DBS and DPS was transported and tested between 2 and 6 weeks later at the Virology Laboratory of Saint-Etienne (France). The second series was routed by mail and tested after up to 3 months of storage at ambient temperature. From the first series, the correlation rate between viral loads obtained from LP and DBS, and from LP and DPS, was 0.98 and 0.99, respectively; specificity of DBS and DPS results was 100%. The results obtained from the second series indicate a great stability of DBS after long-term storage. This study demonstrates that DBSs collected under local conditions in resource-limited settings are suitable for the differed quantification of HIV-1 RNA.

  7. Is sibutramine more than a slim hope?

    PubMed

    2001-12-01

    Sibutramine (Reductil-Abbott Laboratories), an orally active monoamine re-uptake inhibitor, is marketed in the UK for treating overweight adults. The company claims that it "helps obese patients control their eating". Is the drug worth prescribing?

  8. REGULATION OF VASCULOGENESIS AND ANGIOGENESIS

    EPA Science Inventory

    Regulation of vasculogenesis and angiogenesis.
    B.D. Abbott
    Reproductive Toxicology Division, Environmental Protection Agency, Research Triangle Park, North Carolina, USA
    Vasculogenesis and angiogenesis are regulated by a complex, interactive family of receptors and lig...

  9. External Quality Assessment for the Detection of Measles Virus by Reverse Transcription-PCR Using Armored RNA

    PubMed Central

    Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming

    2015-01-01

    In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus. PMID:26244795

  10. External Quality Assessment for the Detection of Measles Virus by Reverse Transcription-PCR Using Armored RNA.

    PubMed

    Zhang, Dong; Sun, Yu; Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming

    2015-01-01

    In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus.

  11. The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7.

    PubMed

    Wang, Shun; Xie, Jiufeng; Jiang, Min; Chang, Keke; Chen, Ruipeng; Ma, Liuzheng; Zhu, Juanhua; Guo, Qingqian; Sun, Haifeng; Hu, Jiandong

    2016-11-04

    The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 using the SPR immunoassay, 3-mercaptopropionic acid (3-MPA) was chemisorbed onto a gold surface via covalent bond for the immobilization of biological species. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were used as crosslinker reagents to enable the reaction between 3-MPA and Escherichia coli O157:H7 antibodies by covalent -CO-NH- amide bonding. The experimental results were obtained from the Escherichia coli O157:H7 positive samples prepared by 10-, 20-, 40-, 80-, and 160-fold dilution respectively, which show that a good linear relationship with the correlation coefficient R of 0.982 existed between the response units from the portable SPR bioanalyzer and the concentration of Escherichia coli O157:H7 positive samples. Moreover, the theoretical detection limit of 1.87 × 10³ cfu/mL was calculated from the positive control samples. Compared with the Escherichia coli O157:H7 ELISA kit, the sensitivity of this portable SPR bioanalyzer is four orders of magnitude higher than the ELISA kit. The results demonstrate that the portable SPR bioanalyzer could provide an alternative method for the quantitative and sensitive determination of Escherichia coli O157:H7 in field.

  12. Multisite evaluation of the BD™ Stem Cell Enumeration (SCE) Kit for CD34+ cell enumeration on the BD FACSCanto II™ and BD FACSCalibur™ flow cytometers

    PubMed Central

    Preti, Robert A; Chan, Wai Shun; Kurtzberg, Joanne; Dornsife, Ronna E.; Wallace, Paul K.; Furlange, Rosemary; Lin, Anna; Omana-Zapata, Imelda; Bonig, Halvard; Tonn, Thorsten

    2018-01-01

    Background Evaluation of the BD™ Stem Cell Enumeration (SCE) Kit was conducted at four clinical sites with flow cytometry CD34+ enumeration, to assess agreement between two investigational methods, the BD FACSCanto™ II and BD FACSCalibur™ systems, and the predicate method (Beckman Coulter Stem-Kit™ reagents). Methods Leftover and delinked specimens (n = 1,032) from clinical flow cytometry testing were analyzed on the BD FACSCanto II (n = 918) and BD FACSCalibur (n = 905) in normal and mobilized blood, frozen and thawed bone marrow, and leucopheresis and cord blood anticoagulated with CPD, ACD-A, heparin, and EDTA alone or in combination. Fresh leucopheresis analysis addressed site equivalency for sample preparation, testing, and analysis. Results The mean relative bias showed agreement within predefined parameters for the BD FACSCanto II (−2.81 to 4.31 ±7.1) and BD FACSCalibur (−2.69 to 5.2 ±7.9). Results are reported as absolute and relative differences compared to the predicate for viable CD34+, percentage of CD34+ in CD45+, and viable CD45+ populations (or gates). Bias analyses of the distribution of the predicate low, mid, and high bin values were done using BD FACSCanto II optimal gating and BD FACSCalibur manual gating for viable CD34+, percentage of CD34+ in CD45+, and viable CD45+. Bias results from both investigational methods show agreement. Deming regression analyses showed a linear relationship with R2 >0.92 for both investigational methods. Discussion In conclusion, the results from both investigational methods demonstrated agreement and equivalence with the predicate method for enumeration of absolute viable CD34+, percentage of viable CD34+ in CD45+, and absolute viable CD45+ populations. PMID:24927716

  13. The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7

    PubMed Central

    Wang, Shun; Xie, Jiufeng; Jiang, Min; Chang, Keke; Chen, Ruipeng; Ma, Liuzheng; Zhu, Juanhua; Guo, Qingqian; Sun, Haifeng; Hu, Jiandong

    2016-01-01

    The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 using the SPR immunoassay, 3-mercaptopropionic acid (3-MPA) was chemisorbed onto a gold surface via covalent bond for the immobilization of biological species. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were used as crosslinker reagents to enable the reaction between 3-MPA and Escherichia coli O157:H7 antibodies by covalent –CO–NH– amide bonding. The experimental results were obtained from the Escherichia coli O157:H7 positive samples prepared by 10-, 20-, 40-, 80-, and 160-fold dilution respectively, which show that a good linear relationship with the correlation coefficient R of 0.982 existed between the response units from the portable SPR bioanalyzer and the concentration of Escherichia coli O157:H7 positive samples. Moreover, the theoretical detection limit of 1.87 × 103 cfu/mL was calculated from the positive control samples. Compared with the Escherichia coli O157:H7 ELISA kit, the sensitivity of this portable SPR bioanalyzer is four orders of magnitude higher than the ELISA kit. The results demonstrate that the portable SPR bioanalyzer could provide an alternative method for the quantitative and sensitive determination of Escherichia coli O157:H7 in field. PMID:27827923

  14. Validation of a Commercial Insulated Isothermal PCR-based POCKIT Test for Rapid and Easy Detection of White Spot Syndrome Virus Infection in Litopenaeus vannamei

    PubMed Central

    Tsai, Yun-Long; Wang, Han-Ching; Lo, Chu-Fang; Tang-Nelson, Kathy; Lightner, Donald; Ou, Bor-Rung; Hour, Ai-Ling; Tsai, Chuan-Fu; Yen, Cheng-Chi; Chang, Hsiao-Fen Grace; Teng, Ping-Hua; Lee, Pei-Yu

    2014-01-01

    Timely pond-side detection of white spot syndrome virus (WSSV) plays a critical role in the implementation of bio-security measures to help minimize economic losses caused by white spot syndrome disease, an important threat to shrimp aquaculture industry worldwide. A portable device, namely POCKIT™, became available recently to complete fluorescent probe-based insulated isothermal PCR (iiPCR), and automatic data detection and interpretation within one hour. Taking advantage of this platform, the IQ Plus™ WSSV Kit with POCKIT system was established to allow simple and easy WSSV detection for on-site users. The assay was first evaluated for its analytical sensitivity and specificity performance. The 95% limit of detection (LOD) of the assay was 17 copies of WSSV genomic DNA per reaction (95% confidence interval [CI], 13 to 24 copies per reaction). The established assay has detection sensitivity similar to that of OIE-registered IQ2000™ WSSV Detection and Protection System with serial dilutions of WSSV-positive Litopenaeus vannamei DNA. No cross-reaction signals were generated from infectious hypodermal and haematopoietic necrosis virus (IHHNV), monodon baculovirus (MBV), and hepatopancreatic parvovirus (HPV) positive samples. Accuracy analysis using700 L. vannamei of known WSSV infection status shows that the established assayhassensitivity93.5% (95% CI: 90.61–95.56%) and specificity 97% (95% CI: 94.31–98.50%). Furthermore, no discrepancy was found between the two assays when 100 random L. vannamei samples were tested in parallel. Finally, excellent correlation was observed among test results of three batches of reagents with 64 samples analyzed in three different laboratories. Working in a portable device, IQ Plus™ WSSV Kit with POCKIT system allows reliable, sensitive and specific on-site detection of WSSV in L. vannamei. PMID:24625894

  15. A novel immobilization multienzyme glucose fluorescence capillary biosensor.

    PubMed

    Li, Yong-Sheng; Du, Yun-Dong; Chen, Ting-Mei; Gao, Xiu-Feng

    2010-02-15

    Based on the immobilization enzyme technology and the fluorescence capillary analysis method, the authors have developed a highly sensitive fluorescence reaction system and a novel immobilization multienzyme glucose fluorescence capillary biosensor for determining glucose contents. Reaction principle of the system is that under the catalysis of glucose oxidase (GOD) and horseradish peroxidase (HRP) immobilized on inner surface of a medical capillary, beta-D-glucose reacts with dissolved oxygen to form gluconic acid-delta-lactone and hydrogen peroxide, and then the latter reacts with l-tyrosine to produce a tyrosine dimer, which has maximal excitation and emission wavelengths at 320 nm and 410 nm, respectively. Fluorescence of the dimer is proportional to the concentration of the beta-D-glucose. Optimization conditions suitable for the reaction system and the biosensor were as follows. Concentration of the L-tyrosine used as fluorescence reagent was 0.15 mol L(-1), the active concentrations of the GOD and the HRP for the immobilization were 15 kU L(-1) and 8 kU L(-1), respectively. Consumptions of the sample and reagents in one determination were 5.0 microL and 15 microL, respectively. Quantitative range of the biosensor for the glucose was in the range 1-10 micromol L(-1), its relative standard deviation was less than 4.9%, and its detection limit was 0.62 micromol L(-1). The biosensor's recovery was in the range 96-105%. Results of some serum determined with the biosensor and with a commercial glucose-kit were well coincident to each other. Accordingly, the biosensor can be applied to the determination of serum glucose contents in the diagnosis of diabetes. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF.

    PubMed

    Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid

    2017-01-18

    Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P < 0.01). Using ≥1.700 plus top three results matching as the cut-off value, species level identifications were obtained from 100/144 (69%) samples using Saponin, 103/144 (72%) using SDS, and 106/144 (74%) using SepsiTyper and there was no statistical difference between the methods. No true discordances between culture and direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.

  17. Evaluation of Two Lyophilized Molecular Assays to Rapidly Detect Foot-and-Mouth Disease Virus Directly from Clinical Samples in Field Settings.

    PubMed

    Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L

    2017-06-01

    Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  18. Assessment of hydrologic and water quality data collected in Abbotts Lagoon watershed, Point Reyes National Seashore, California, during water years 1999 and 2000

    USGS Publications Warehouse

    Kratzer, Charles R.; Saleh, Dina K.; Zamora, Celia

    2006-01-01

    Abbotts Lagoon is part of Point Reyes National Seashore, located about 40 miles northwest of San Francisco and about 20 miles south of Bodega Bay. Water-quality samples were collected quarterly during water year 1999 at a site in each of three connected lagoons that make up Abbotts Lagoon and at a site in its most significant tributary. The quarterly samples were analyzed for major ions, nutrients, and chlorophyll-a. A bed-sediment sample was collected in each lagoon during August 1999 and was analyzed for organic carbon, iron, and total phosphorus. Seven tributaries were sampled during a February 1999 storm and four during an April 1999 storm. These samples were analyzed only for nutrients. One storm sample collected in April 1999 from a tributary downstream of the I Ranch dairy was analyzed for a suite of 47 compounds indicative of wastewater. Continuous water-level recorders were installed in the most significant tributary and the two largest lagoons for portions of the study. A water budget analysis for an April 2000 storm indicated that the main tributary accounted for 85 percent of surface inflows to Abbotts Lagoon. The portion of the surface inflow from the main tributary was lower in the February 1999 storms and is a function of upstream storage and vegetative growth in the tributary basins. Another water budget analysis for a period of no surface inflow (June and July 2000) indicated that the net ground-water contribution was an outflow (seepage) from Abbotts Lagoon of about 0.3 ft3/s. Salinity increased and nutrient concentrations decreased from upstream to downstream in the chain of lagoons. The lower lagoon, nearest the ocean, had less organic carbon and total phosphorus in the bed sediment than the upper lagoons. The two tributaries originating in the I Ranch dairy had the highest concentrations of nutrients in storm runoff, and the highest loading rates and yields of ammonia and phosphorus. These tributaries account for only 10.3 percent of the area drained by the sampled tributaries, but contributed 83 percent of the ammonia load and 79 percent of the orthophosphate load. The basins with the highest nutrient loading rates and yields had the highest percentage of dairy and (or) ranching impacted land use and, to a lesser extent, grazing land use. The ratios of inorganic nitrogen to phosphorus in the lagoons ranged from 0.1 to 9.5 in the upper lagoon, 0.10 to 0.15 in the middle lagoon, and 0.05 to 0.10 in the lower lagoon. Thus, there is an abundance of phosphorus in the lagoons, and nitrogen appears to be limiting the growth of phytoplankton. Two sterols indicative of fecal material were among 11 compounds detected in the sample collected for analysis of wastewater indicators from a tributary downstream of the I Ranch dairy.

  19. Mercury in the environment

    ScienceCinema

    Idaho National Laboratory - Mike Abbott

    2017-12-09

    Abbott works for Idaho National Laboratory as an environmental scientist. Using state-of-thescienceequipment, he continuously samples the air, looking for mercury. In turn, he'll analyzethis long-term data and try to figure out the mercury's point of or

  20. Integrated Warfighter Biodefense Program (IWBP)

    DTIC Science & Technology

    2011-08-01

    Distribution. Sincerely, Frank T. Abbott VP of Administration & Finance fta @quantumleap.us cc: Dr. Ganesh Vaidyanathan, Project Manager, Code 34...goals of IWBP. Areas of potential application include health care administration, clinical data analysis and health care research applications

  1. Aging stability of complete blood count and white blood cell differential parameters analyzed by Abbott CELL-DYN Sapphire hematology analyzer.

    PubMed

    Hedberg, P; Lehto, T

    2009-02-01

    This study presents the results of an aging stability study of complete blood count (CBC) and leukocyte differential parameters using the Abbott CELL-DYN Sapphire hematology analyzer. Stability studies showed no substantial change in CBC parameters up to 24-48 h at +23 +/- 2 degrees C (room temperature), except for optical platelet count (PLTo). For specimens aged over 24, the value of impedance platelet count yielded more reliable results than the routine PLTo. White blood cell (WBC) differential parameters, except eosinophils, were stable for up to 48 h at +23 +/- 2 degrees C. CBC parameters were stable for 72 h, except mean platelet volume, which slightly increased between 48 and 72 h, at +4 degrees C. WBC differentials were stable 48-72 h, with a slight decrease observed in absolute neutrophils and lymphocytes at +4 degrees C.

  2. The evolution of the matrix metalloproteinase inhibitor drug discovery program at abbott laboratories.

    PubMed

    Wada, Carol K

    2004-01-01

    Matrix metalloproteinases (MMPs) have been implicated in several pathologies. At Abbott Laboratories, the matrix metalloproteinases inhibitor drug discovery program has focused on the discovery of a potent, selective, orally bioavailable MMP inhibitor for the treatment of cancer. The program evolved from early succinate-based inhibitors to utilizing in-house technology such as SAR by NMR to develop a novel class of biaryl hydroxamate MMP inhibitors. The metabolic instability of the biaryl hydroxamates led to the discovery of a new class of N-formylhydroxylamine (retrohydroxamate) biaryl ethers, exemplified by ABT-770 (16). Toxicity issues with this pre-clinical candidate led to the discovery of another novel class of retrohydroxamate MMP inhibitors, the phenoxyphenyl sulfones such as ABT-518 (19j). ABT-518 is a potent, orally bioavailable, selective inhibitor of MMP-2 and 9 over MMP-1 that has been evaluated in Phase I clinical trials in cancer patients.

  3. Radotinib induces high cytotoxicity in c-KIT positive acute myeloid leukemia cells.

    PubMed

    Heo, Sook-Kyoung; Noh, Eui-Kyu; Kim, Jeong Yi; Jo, Jae-Cheol; Choi, Yunsuk; Koh, SuJin; Baek, Jin Ho; Min, Young Joo; Kim, Hawk

    2017-06-05

    Previously, we reported that radotinib, a BCR-ABL1 tyrosine kinase inhibitor, induced cytotoxicity in acute myeloid leukemia (AML) cells. However, the effects of radotinib in the subpopulation of c-KIT-positive AML cells were unclear. We observed that low-concentration radotinib had more potent cytotoxicity in c-KIT-positive cells than c-KIT-negative cells from AML patients. To address this issue, cell lines with high c-KIT expression, HEL92.1.7, and moderate c-KIT expression, H209, were selected. HEL92.1.7 cells were grouped into intermediate and high c-KIT expression populations. The cytotoxicity of radotinib against the HEL92.1.7 cell population with intermediate c-KIT expression was not different from that of the population with high c-KIT expression. When H209 cells were grouped into c-KIT expression-negative and c-KIT expression-positive populations, radotinib induced cytotoxicity in the c-KIT-positive population, but not the c-KIT-negative population. Thus, radotinib induces cytotoxicity in c-KIT-positive cells, regardless of the c-KIT expression intensity. Therefore, radotinib induces significant cytotoxicity in c-KIT-positive AML cells, suggesting that radotinib is a potential target agent for the treatment of c-KIT-positive malignancies including AML. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Techni-kits and Techni-kit Building Systems

    NASA Technical Reports Server (NTRS)

    Callender, E. D.; Hartsough, C.; Morris, R. V.; Yamamoto, Y.

    1985-01-01

    Techni-kits consists of theories, methods, standards and computer based tools that assist in design of information-intensive systems. Techni-kit "building system" is techni-kit that builds techni-kits.

  5. Baseline morning cortisol level as a predictor of pituitary-adrenal reserve: a comparison across three assays.

    PubMed

    Sbardella, Emilia; Isidori, Andrea M; Woods, Conor P; Argese, Nicola; Tomlinson, Jeremy W; Shine, Brian; Jafar-Mohammadi, Bahram; Grossman, Ashley B

    2017-02-01

    The short ACTH stimulation test (250 μg) is the dynamic test most frequently used to assess adrenal function. It is possible that a single basal cortisol could be used to predict the dynamic response, but research has been hampered by the use of different assays and thresholds. To propose a morning baseline cortisol criterion of three of the most commonly used modern cortisol immunoassays - Advia Centaur (Siemens), Architect (Abbott) and the Roche Modular System (Roche) - that could predict adrenal sufficiency. Observational, retrospective cross-sectional study at two centres. Retrospective analysis of the results of 1019 Short Synacthen tests (SSTs) with the Advia Centaur, 449 SSTs with the Architect and 2050 SSTs with the Roche Modular System assay. Serum cortisol levels were measured prior to injection of 250 μg Synacthen and after 30 min. Overall, we were able to collate data from a total of 3518 SSTs in 3571 patients. Using receiver-operator curve analysis, baseline cortisol levels for predicting passing the SST with 100% specificity were 358 nmol/l for Siemens, 336 nmol/l for Abbott and 506 nmol/l for Roche. Utilizing these criteria, 589, 158 and 578 SSTs, respectively, for Siemens, Abbott and Roche immunoassays could have been avoided. We have defined assay-specific morning cortisol levels that are able to predict the integrity of the hypothalamo-pituitary-adrenal axis. We propose that this represents a valid tool for the initial assessment of adrenal function and has the potential to obviate the need for dynamic testing in a significant number of patients. © 2016 John Wiley & Sons Ltd.

  6. An improved Abbott ARCHITECT assay for the detection of hepatitis B virus surface antigen (HBsAg).

    PubMed

    Lou, Sheng C; Pearce, Sandra K; Lukaszewska, Teresa X; Taylor, Russell E; Williams, Gregg T; Leary, Thomas P

    2011-05-01

    The sensitive and accurate detection of hepatitis B virus surface antigen (HBsAg) is critical to the identification of infection and the prevention of transfusion transmitted disease. Improvement in HBsAg assay sensitivity is essential to reduce the window to detect an acute HBV infection. Additionally, the sensitive detection of HBsAg mutants that continue to evolve due to vaccine escape, immune selection and an error prone reverse transcriptase is a necessity. A fully automated HBsAg prototype assay on the Abbott ARCHITECT instrument was developed to improve sensitivity and mutant detection. This magnetic microparticle-based assay utilizes anti-HBsAg monoclonal antibodies to capture antigen present in serum or plasma. Captured antigen is then detected using anti-HBsAg antibody conjugated with the chemiluminescent compound, acridinium. The sensitivity of the ARCHITECT HBsAg prototype assay was improved as compared to the current ARCHITECT, PRISM, and competitor HBsAg assays. The enhancement in assay sensitivity was demonstrated by the use of commercially available HBV seroconversion panels. The prototype assay detected more panel members (185 of 383) vs. the current ARCHITECT (171), PRISM (181), or competitor HBsAg assays (73/140 vs. 62/140, respectively). The ARCHITECT prototype assay also efficiently detected all mutants evaluated. Finally, the sensitivity improvement did not compromise the specificity of the assay (99.94%). An improved Abbott ARCHITECT HBsAg prototype assay with enhanced detection of HBsAg and HBsAg mutants, as well as equivalent specificity was developed for the detection, diagnosis, and management of HBV infection. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Technology evaluation: adalimumab, Abbott laboratories.

    PubMed

    Lorenz, Hanns M

    2002-04-01

    Adalimumab (D2E7), a human monoclonal antibody that binds to and neutralizes TNFa, is being developed by Abbott (formerly Knoll), under license from Cambridge Antibody Technology (CAT), for the potential treatment of inflammatory disorders such as rheumatoid arthritis (RA) and Crohn's disease. It is also being investigated for the potential treatment of coronary heart disease. Phase II studies for Crohn's disease and phase III for RA were ongoing throughout 2001. Limited data are only available for RA. In January 2002, it was reported that phase III trials of adalimumab for RA had been completed, but details have not been published in the primary literature so far. At this time CAT and Abbott expected to file for US approval in the second quarter of 2002 with a launch date anticipated for 2003. Phase III data are expected to be presented at the European League Against Rheumatism meeting in June 2002. In November 2000, Lehman Brothers predicted a US launch in June 2002 with peak US sales of $600 million in 2007 and a launch in non-US markets in 2003 with peak sales in these markets of $300 million in 2008. In December 2000, Merrill Lynch predicted regulatory clearance in the second half of 2003. The probability of adalimumab reaching the market is estimated to be 70%. In December 2000, Merrill Lynch predicted a 2003 launch, with estimated sales of pounds sterling 3.65 million in that year rising to pounds sterling 30.14 million in 2010. In March 2001, ABN AMRO predicted sales of $73 million in 2003 rising to $392 million in 2007.

  8. Evaluating new HbA1c methods for adoption by the IFCC and NGSP reference networks using international quality targets.

    PubMed

    Lenters-Westra, Erna; English, Emma

    2017-08-28

    As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs <3% in SI units and <2% in NGSP units at 46 mmol/mol (6.4%) and 72 mmol/mol (8.7%) and passed the NGSP criteria when compared with six secondary reference measurement procedures (SRMPs). Sigma was 8.6 for Abbott Enzymatic, 3.3 for Roche Cobas c513 and 6.9 for Tosoh G11. No clinically significant interference was detected for the common Hb variants for the three methods. All three methods performed well and are suitable for clinical application in the analysis of HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.

  9. Establishing a cost-per-result of laboratory-based, reflex Cryptococcal antigenaemia screening (CrAg) in HIV+ patients with CD4 counts less than 100 cells/μl using a Lateral Flow Assay (LFA) at a typical busy CD4 laboratory in South Africa.

    PubMed

    Cassim, Naseem; Schnippel, Kathryn; Coetzee, Lindi Marie; Glencross, Deborah Kim

    2017-01-01

    Cryptococcal meningitis is a major cause of mortality and morbidity in countries with high HIV prevalence, primarily affecting patients whose CD4 are < = 100 cells/μl. Routine Cryptococcal Antigen (CrAg) screening is thus recommended in the South African HIV treatment guidelines for all patients with CD4 counts < = 100 cells/μl, followed by pre-emptive anti-fungal therapy where CrAg results are positive. A laboratory-based reflexed CrAg screening approach, using a Lateral Flow Assay (LFA) on remnant EDTA CD4 blood samples, was piloted at three CD4 laboratories. This study aimed to assess the cost-per-result of laboratory-based reflexed CrAg screening at one pilot CD4 referral laboratory. CD4 test volumes from 2014 were extracted to estimate percentage of CD4 < = 100 cells/μl. Daily average volumes were derived, assuming 12 months per/year and 21.73 working days per/month. Costing analyses were undertaken using Microsoft Excel and Stata with a provider prospective. The cost-per-result was estimated using a bottom-up method, inclusive of test kits and consumables (reagents), laboratory equipment and technical effort costs. The ZAR/$ exchange of 14.696/$1 was used, where applicable. One-way sensitivity analyses on the cost-per-result were conducted for possible error rates (3%- 8%, reductions or increases in reagent costs as well as test volumes (ranging from -60% to +60%). The pilot CD4 laboratory performed 267000 CD4 tests in 2014; ~ 9.3% (27500) reported CD4< = 100 cells/μl, equivalent to 106 CrAg tests performed daily. A batch of 30-tests could be performed in 1.6 hours, including preparation and analysis time. A cost-per-result of $4.28 was reported, with reagents contributing $3.11 (72.8%), while technical effort and laboratory equipment overheads contributed $1.17 (27.2%) and $0.03 (<1%) respectively. One-way sensitivity analyses including increasing or decreasing test volumes by 60% revealed a cost-per-result range of $3.84 to $6.03. A cost-per-result of $4.28 was established in a typical CD4 service laboratory to enable local budgetary cost projections and programmatic cost-effectiveness modelling. Varying reagent costs linked to currency exchange and varying test volumes in different levels of service can lead to varying cost-per-test and technical effort to manage workload, with an inverse relationship of higher costs expected at lower volumes of tests.

  10. A decrease in ubiquitination and resulting prolonged life-span of KIT underlies the KIT overexpression-mediated imatinib resistance of KIT mutation-driven canine mast cell tumor cells.

    PubMed

    Kobayashi, Masato; Kuroki, Shiori; Kurita, Sena; Miyamoto, Ryo; Tani, Hiroyuki; Tamura, Kyoichi; Bonkobara, Makoto

    2017-10-01

    Overexpression of KIT is one of the mechanisms that contributes to imatinib resistance in KIT mutation-driven tumors. Here, the mechanism underlying this overexpression of KIT was investigated using an imatinib-sensitive canine mast cell tumor (MCT) line CoMS, which has an activating mutation in KIT exon 11. A KIT-overexpressing imatinib-resistant subline, rCoMS1, was generated from CoMS cells by their continuous exposure to increasing concentrations of imatinib. Neither a secondary mutation nor upregulated transcription of KIT was detected in rCoMS1 cells. A decrease in KIT ubiquitination, a prolonged KIT life-span, and KIT overexpression were found in rCoMS1 cells. These events were suppressed by withdrawal of imatinib and were re-induced by re‑treatment with imatinib. These findings suggest that imatinib elicited overexpression of KIT via suppression of its ubiquitination. These results also indicated that imatinib-induced overexpression of KIT in rCoMS1 cells was not a permanently acquired feature but was a reversible response of the cells. Moreover, the pan deubiquitinating enzyme inhibitor PR619 prevented imatinib induction of KIT overexpression, suggesting that the imatinib-induced decrease in KIT ubiquitination could be mediated by upregulation and/or activation of deubiquitinating enzyme(s). It may be possible that a similar mechanism of KIT overexpression underlies the acquisition of imatinib resistance in some human tumors that are driven by KIT mutation.

  11. 76 FR 28241 - Public Land Order No. 7766; Extension of Public Land Order No. 6856; Oregon

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-16

    ... is necessary to continue protection of the unique natural and ecological research values of the... extension to continue protection of the unique natural and ecological research values at the Abbott Creek...

  12. Surviving the Legitimacy Challenge.

    ERIC Educational Resources Information Center

    Yinger, Robert J.; Nolen, Amanda L.

    2003-01-01

    Uses Andrew Abbott's sociological analysis of the professionalization process and the legal term "jurisdiction" to explore the legitimacy of the teaching profession. Discusses professional jurisdiction, knowledge jurisdiction, and social jurisdiction. Offers recommendations for universities to gain jurisdiction and legitimacy in the education of…

  13. Amino acid analysis in physiological samples by GC-MS with propyl chloroformate derivatization and iTRAQ-LC-MS/MS.

    PubMed

    Dettmer, Katja; Stevens, Axel P; Fagerer, Stephan R; Kaspar, Hannelore; Oefner, Peter J

    2012-01-01

    Two mass spectrometry-based methods for the quantitative analysis of free amino acids are described. The first method uses propyl chloroformate/propanol derivatization and gas chromatography-quadrupole mass spectrometry (GC-qMS) analysis in single-ion monitoring mode. Derivatization is carried out directly in aqueous samples, thereby allowing automation of the entire procedure, including addition of reagents, extraction, and injection into the GC-MS. The method delivers the quantification of 26 amino acids. The isobaric tagging for relative and absolute quantification (iTRAQ) method employs the labeling of amino acids with isobaric iTRAQ tags. The tags contain two different cleavable reporter ions, one for the sample and one for the standard, which are detected by fragmentation in a tandem mass spectrometer. Reversed-phase liquid chromatography of the labeled amino acids is performed prior to mass spectrometric analysis to separate isobaric amino acids. The commercial iTRAQ kit allows for the analysis of 42 physiological amino acids with a respective isotope-labeled standard for each of these 42 amino acids.

  14. Construction, expression, purification and biotin labeling of a single recombinant multi-epitope antigen for double-antigen sandwich ELISA to detect hepatitis C virus antibody.

    PubMed

    He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu

    2011-08-01

    Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.

  15. An Accelerated Analytical Process for the Development of STR Profiles for Casework Samples.

    PubMed

    Laurin, Nancy; Frégeau, Chantal J

    2015-07-01

    Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single-source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30-min lysis step, a 27-min DNA extraction using the Promega Maxwell(®) 16 System, DNA quantification in <1 h using the Qiagen Investigator(®) Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpFℓSTR(®) Identifiler(®), and analysis of the profiles on the 3500-series Genetic Analyzer. This combination of fast individual steps produces high-quality profiling results and offers a cost-effective alternative approach to rapid DNA analysis. © 2015 American Academy of Forensic Sciences.

  16. Oncogenic signaling by Kit tyrosine kinase occurs selectively on the Golgi apparatus in gastrointestinal stromal tumors

    PubMed Central

    Obata, Y; Horikawa, K; Takahashi, T; Akieda, Y; Tsujimoto, M; Fletcher, J A; Esumi, H; Nishida, T; Abe, R

    2017-01-01

    Gastrointestinal stromal tumors (GISTs) are caused by gain-of-function mutations in the Kit receptor tyrosine kinase. Most primary GIST patients respond to the Kit inhibitor imatinib, but this drug often becomes ineffective because of secondary mutations in the Kit kinase domain. The characteristic intracellular accumulation of imatinib-sensitive and -resistant Kit protein is well documented, but its relationship to oncogenic signaling remains unknown. Here, we show that in cancer tissue from primary GIST patients as well as in cell lines, mutant Kit accumulates on the Golgi apparatus, whereas normal Kit localizes to the plasma membrane (PM). In imatinib-resistant GIST with a secondary Kit mutation, Kit localizes predominantly on the Golgi apparatus. Both imatinib-sensitive and imatinib-resistant Kit (Kit(mut)) become fully auto-phosphorylated only on the Golgi and only if in a complex-glycosylated form. Kit(mut) accumulates on the Golgi during the early secretory pathway, but not after endocytosis. The aberrant kinase activity of Kit(mut) prevents its export from the Golgi to the PM. Furthermore, Kit(mut) on the Golgi signals and activates the phosphatidylinositol 3-kinase–Akt (PI3K–Akt) pathway, signal transducer and activator of transcription 5 (STAT5), and the Mek–Erk pathway. Blocking the biosynthetic transport of Kit(mut) to the Golgi from the endoplasmic reticulum inhibits oncogenic signaling. PM localization of Kit(mut) is not required for its signaling. Activation of Src-family tyrosine kinases on the Golgi is essential for oncogenic Kit signaling. These results suggest that the Golgi apparatus serves as a platform for oncogenic Kit signaling. Our study demonstrates that Kit(mut)’s pathogenicity is related to its mis-localization, and may offer a new strategy for treating imatinib-resistant GISTs. PMID:28192400

  17. Protein kinase C-δ-mediated recycling of active KIT in colon cancer.

    PubMed

    Park, Misun; Kim, Won Kyu; Song, Meiying; Park, Minhee; Kim, Hyunki; Nam, Hye Jin; Baek, Sung Hee; Kim, Hoguen

    2013-09-15

    Abnormal signaling through receptor tyrosine kinase (RTK) moieties is important in tumorigenesis and drug targeting of colorectal cancers. Wild-type KIT (WT-KIT), a RTK that is activated upon binding with stem cell factor (SCF), is highly expressed in some colon cancers; however, little is known about the functional role of SCF-dependent KIT activation in colon cancer pathogenesis. We aimed to elucidate the conditions and roles of WT-KIT activation in colon cancer tumorigenesis. Colorectal cancers with KIT expression were characterized by immunoblotting and immunohistochemistry. The biologic alterations after KIT-SCF binding were analyzed with or without protein kinase C (PKC) activation. We found that WT-KIT was expressed in a subset of colon cancer cell lines and was activated by SCF, leading to activation of downstream AKT and extracellular signal-regulated kinase (ERK) signaling pathways. We also showed that KIT expression gradually decreased, after prolonged SCF stimulation, due to lysosomal degradation. Degradation of WT-KIT after SCF binding was significantly rescued when PKC was activated. We also showed the involvement of activated PKC-δ in the recycling of WT-KIT. We further showed that a subset of colorectal cancers exhibit expressions of both WT-KIT and activated PKC-δ and that expression of KIT is correlated with poor patient survival (P = 0.004). Continuous downstream signal activation after KIT-SCF binding is accomplished through PKC-δ-mediated recycling of KIT. This sustained KIT activation may contribute to tumor progression in a subset of colon cancers with KIT expression and might provide the rationale for a therapeutic approach targeting KIT. ©2013 AACR.

  18. Cardiac c-Kit Biology Revealed by Inducible Transgenesis.

    PubMed

    Gude, Natalie A; Firouzi, Fareheh; Broughton, Kathleen M; Ilves, Kelli; Nguyen, Kristine P; Payne, Christina R; Sacchi, Veronica; Monsanto, Megan M; Casillas, Alexandria R; Khalafalla, Farid G; Wang, Bingyan J; Ebeid, David E; Alvarez, Roberto; Dembitsky, Walter P; Bailey, Barbara A; van Berlo, Jop; Sussman, Mark A

    2018-06-22

    Biological significance of c-Kit as a cardiac stem cell marker and role(s) of c-Kit+ cells in myocardial development or response to pathological injury remain unresolved because of varied and discrepant findings. Alternative experimental models are required to contextualize and reconcile discordant published observations of cardiac c-Kit myocardial biology and provide meaningful insights regarding clinical relevance of c-Kit signaling for translational cell therapy. The main objectives of this study are as follows: demonstrating c-Kit myocardial biology through combined studies of both human and murine cardiac cells; advancing understanding of c-Kit myocardial biology through creation and characterization of a novel, inducible transgenic c-Kit reporter mouse model that overcomes limitations inherent to knock-in reporter models; and providing perspective to reconcile disparate viewpoints on c-Kit biology in the myocardium. In vitro studies confirm a critical role for c-Kit signaling in both cardiomyocytes and cardiac stem cells. Activation of c-Kit receptor promotes cell survival and proliferation in stem cells and cardiomyocytes of either human or murine origin. For creation of the mouse model, the cloned mouse c-Kit promoter drives Histone2B-EGFP (enhanced green fluorescent protein; H2BEGFP) expression in a doxycycline-inducible transgenic reporter line. The combination of c-Kit transgenesis coupled to H2BEGFP readout provides sensitive, specific, inducible, and persistent tracking of c-Kit promoter activation. Tagging efficiency for EGFP+/c-Kit+ cells is similar between our transgenic versus a c-Kit knock-in mouse line, but frequency of c-Kit+ cells in cardiac tissue from the knock-in model is 55% lower than that from our transgenic line. The c-Kit transgenic reporter model reveals intimate association of c-Kit expression with adult myocardial biology. Both cardiac stem cells and a subpopulation of cardiomyocytes express c-Kit in uninjured adult heart, upregulating c-Kit expression in response to pathological stress. c-Kit myocardial biology is more complex and varied than previously appreciated or documented, demonstrating validity in multiple points of coexisting yet heretofore seemingly irreconcilable published findings. © 2018 American Heart Association, Inc.

  19. Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes detection kit in combination with ShortPrep foodproof II Kit. Performance-Tested Method 070401.

    PubMed

    Junge, Benjamin; Berghof-Jäger, Kornelia

    2006-01-01

    A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.

  20. Advantage of using a home-made ELISA kit for detection of Helicobacter pylori infection over commercially imported kits.

    PubMed

    Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A

    2008-01-01

    To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  1. 78 FR 52981 - Investigations Regarding Eligibility to Apply for Worker Adjustment Assistance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-27

    ...-- Tulsa, OK 08/02/13 08/01/13 Wholesale Customer Application Support Team (Workers). 82953 Abbott Laboratories, Santa Clara, CA........ 08/02/13 08/01/13 including on-site leased workers from ATR Int'l (State...

  2. 77 FR 16039 - Abbott Laboratories et al.; Withdrawal of Approval of 35 New Drug Applications and 64 Abbreviated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-19

    ... Do. nitroprusside for Injection USP), 50 mg. ANDA 071015 Haloperidol Oral Teva Pharmaceuticals... 075065 Acyclovir Sodium for Do. Injection. ANDA 075176 Haloperidol Do. Decanoate Injection, 50 mg/mL and...

  3. Investigation of an algorithm for anti HCV EIA reactivity in blood donor screening in Turkey in the absence of nucleic acid amplification screening.

    PubMed

    Karakoc, Ayse Esra; Berkem, Rukiye; Irmak, Hasan; Demiroz, Ali Pekcan; Yenicesu, Idil; Ertugrul, Nigar; Arslan, Önder; Kemahli, Sabri; Yilmaz, Sevinc; Ozcebe, Osman; Kara, Abdurrahman; Ozet, Gulsum; Acikgoz, Ziya Cibali; Acikgoz, Tulin

    2017-10-01

    In this study we aimed to propose an algorithm for initial anti HCV EIA reactive blood donations in Turkey where nucleic acid amplification tests are not yet obligatory for donor screening. A total of 416 anti HCV screening test reactive donor samples collected from 13 blood centers from three cities in Turkey were tested in duplicate by Ortho HCV Ab Version 3.0 and Radim HCV Ab. All the repeat reactive samples were tested by INNO-LIA HCV Ab 3.0 or Chiron RIBA HCV 3.0 and Abbott Real Time HCV. Intra-assay correlations were calculated with Pearson r test. ROC analysis was used to study the relationship between EIA tests and the confirmatory tests. The number of repeat reactive results with Ortho EIA were 221 (53.1%) whereas that of microEIA, 62 (14.9%). Confirmed positivity rate was 14.6% (33/226) by RIBA and 10.6% (24/226) by NAT. Reactive PCR results were predicted with 100% sensitivity and 95% specificity with S/CO levels of 8.1 with Ortho EIA and 3.4 with microEIA. Repeat reactivity rates declined with a second HCV antibody assay. Samples repeat reactive with one HCV antibody test and negative with the other were all NAT negative. All the NAT reactive samples were RIBA positive. None of the RIBA indeterminate or negative samples were NAT reactive. Considering the threshold values for EIA kits determined by ROC analysis NAT was decided to be performed for the samples above the threshold value and a validated supplemental HCV antibody test for the samples below. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Rapid-prenatal diagnosis through fluorescence in situ hybridization for preventing aneuploidy related birth defects

    PubMed Central

    Fauzdar, Ashish; Chowdhry, Mohit; Makroo, R. N.; Mishra, Manoj; Srivastava, Priyanka; Tyagi, Richa; Bhadauria, Preeti; Kaul, Anita

    2013-01-01

    BACKGROUND AND OBJECTIVE: Women with high-risk pregnancies are offered prenatal diagnosis through amniocentesis for cytogenetic analysis of fetal cells. The aim of this study was to evaluate the effectiveness of the rapid fluorescence in situ hybridization (FISH) technique for detecting numerical aberrations of chromosomes 13, 21, 18, X and Y in high-risk pregnancies in an Indian scenario. MATERIALS AND METHODS: A total of 163 samples were received for a FISH and/or a full karyotype for prenatal diagnosis from high-risk pregnancies. In 116 samples both conventional culture techniques for getting karyotype through G-banding techniques were applied in conjunction to FISH test using the AneuVysion kit (Abbott Molecular, Inc.), following standard recommended protocol to compare the both the techniques in our setup. RESULTS: Out of 116 patients, we got 96 normal for the five major chromosome abnormality and seven patients were found to be abnormal (04 trisomy 21, 02 monosomy X, and 01 trisomy 13) and all the FISH results correlated with conventional cytogenetics. To summarize the results of total 163 patients for the major chromosomal abnormalities analyzed by both/or cytogenetics and FISH there were 140 (86%) normal, 9 (6%) cases were abnormal and another 4 (2.5%) cases were suspicious mosaic and 10 (6%) cases of culture failure. The diagnostic detection rate with FISH in 116 patients was 97.5%. There were no false-positive and false-negative autosomal or sex chromosomal results, within our established criteria for reporting FISH signals. CONCLUSION: Rapid FISH is a reliable and prompt method for detecting numerical chromosomal aberrations and has now been implemented as a routine diagnostic procedure for detection of fetal aneuploidy in India. PMID:23901191

  5. Rapid-prenatal diagnosis through fluorescence in situ hybridization for preventing aneuploidy related birth defects.

    PubMed

    Fauzdar, Ashish; Chowdhry, Mohit; Makroo, R N; Mishra, Manoj; Srivastava, Priyanka; Tyagi, Richa; Bhadauria, Preeti; Kaul, Anita

    2013-01-01

    Women with high-risk pregnancies are offered prenatal diagnosis through amniocentesis for cytogenetic analysis of fetal cells. The aim of this study was to evaluate the effectiveness of the rapid fluorescence in situ hybridization (FISH) technique for detecting numerical aberrations of chromosomes 13, 21, 18, X and Y in high-risk pregnancies in an Indian scenario. A total of 163 samples were received for a FISH and/or a full karyotype for prenatal diagnosis from high-risk pregnancies. In 116 samples both conventional culture techniques for getting karyotype through G-banding techniques were applied in conjunction to FISH test using the AneuVysion kit (Abbott Molecular, Inc.), following standard recommended protocol to compare the both the techniques in our setup. Out of 116 patients, we got 96 normal for the five major chromosome abnormality and seven patients were found to be abnormal (04 trisomy 21, 02 monosomy X, and 01 trisomy 13) and all the FISH results correlated with conventional cytogenetics. To summarize the results of total 163 patients for the major chromosomal abnormalities analyzed by both/or cytogenetics and FISH there were 140 (86%) normal, 9 (6%) cases were abnormal and another 4 (2.5%) cases were suspicious mosaic and 10 (6%) cases of culture failure. The diagnostic detection rate with FISH in 116 patients was 97.5%. There were no false-positive and false-negative autosomal or sex chromosomal results, within our established criteria for reporting FISH signals. Rapid FISH is a reliable and prompt method for detecting numerical chromosomal aberrations and has now been implemented as a routine diagnostic procedure for detection of fetal aneuploidy in India.

  6. Exposure to hepatitis E virus, hepatitis A virus and Borrelia spp. infections in forest rangers from a single forest district in western Poland.

    PubMed

    Bura, Maciej; Bukowska, Alicja; Michalak, Michał; Bura, Aleksandra; Nawrocki, Mariusz J; Karczewski, Marek; Mozer-Lisewska, Iwona

    2018-03-13

    Hepatitis E virus (HEV) infection is an emerging problem in developed countries. At least 2 zoonotic genotypes of the virus (HEV-3 and HEV-4) infect human beings. There are some data suggesting that forest rangers (FRs) can be at a higher risk of contact with HEV. The aim of this study was to assess the prevalence of HEV exposure markers in FRs from a single forest district in Greater Poland in relation to anti-HAV (hepatitis A virus) IgG, and anti-Borrelia spp. IgM and IgG antibodies. In total, 138 participants (48 FRs and 90 blood donors - BDs) were tested for anti-HEV IgM and IgG (EUROIMMUN Medizinische Labordiagnostika AG, Luebeck, Germany) and 96 individuals (48 FRs and 48 BDs) were tested for anti-HAV IgG (ARCHITECT immunoassays, Abbott Laboratories, Wiesbaden, Germany); anti-Borrelia IgM and IgG (EUROIMMUN kits) were assessed in FRs only. Anti-HEV markers were detected in 3 participants (2.2%; IgM in 1 FR, IgG in 2 BDs), less frequently than anti-HAV (16 out of 96 individuals, about 17%; FRs 19% vs BDs 15%) or anti-Borrelia antibodies (18 out of 48 individuals, 37.5%) (p < 0.0001 for both). Older study participants (≥45 years of age) were more frequently HAV-seropositive (29% vs 4% of the younger individuals; p = 0.0012). We failed to unequivocally prove HEV exposure in FRs. The HAV seroprevalence in this study paralleled the situation in the general population. Exposure to Borrelia spp. in FRs was common.

  7. Socio-demographic Characteristics of Adults Screened for Human Immunodeficiency Virus Infection in Ahoada–East Local Government Area in the Niger Delta of Nigeria

    PubMed Central

    Obi, Azuonwu; Osaro, Erhabor; Nnenna, Frank-Peterside

    2011-01-01

    Background: Human immunodeficiency virus (HIV), the pathogen responsible for the acquired immunodeficiency syndrome and the most significant emerging infectious disease is causing health, social, and developmental problems to mankind. Aims, Setting and Design: This is a cross-sectional study to evaluate the socio-demographic characteristics of adults screened for HIV infection in Ahoada Community in Rivers State in the Niger Delta of Nigeria. Materials and Methods: HIV antibodies were detected using “Determine” (Abbott Laboratories, Japan), Start–Pak (Chembio Diagnostics, USA) and SD Bioline HIV-1/2 kits (Standard Diagnostics, Korea). All test procedures were carried out according to the manufacturers’ instructions. Subjects included 152) consecutively recruited adults consisting of 955 females and 566 males aged 18-54 years with a mean age of 36.25±7.02 years. Statistical Analysis: Data were entered and analyzed using statistical package SPSS version 9. A P-value ≤0.05 were considered statistically significant in all statistical comparisms. Results and Conclusion: Out of a total of 1521 persons screened for HIV infection, 162 persons tested positive for HIV (10.6%). HIV infection was higher among females (10.9%) compared to males (10.1%) and in the 25-34 and 45-60 years age groups (11.1%) (P= 0.08). HIV-1 was the predominant subtype (74%) compared to 26% for dual HIV-1 and 2. This study indicates the urgent need for both government and non-governmental organizations to intensify awareness campaign programme to reduce the spread of the HIV infection in the area with emphasis on behavioral change and economic empowerment of the people as well as provision of universal access to antiretroviral therapy for those with HIV infection. PMID:22223994

  8. Monoclonal antibody fluorescence for routine lymphocyte subpopulation analysis with the Abbott CELL-DYN Sapphire haematology analyser.

    PubMed

    Molero, T; Lemes, A; DE LA Iglesia, S; Scott, C S

    2007-12-01

    Using previously described procedures, this study quantified T-cell, T-cell subset, B-cell and NK-cell populations with the CD-Sapphire haematology analyser in a series of patients with mild to moderate lymphocytosis. Lymphocyte counts ranged from 6.0 to 14.9 x 10(9)/l, with 86/97 being <10.0 x 10(9)/l. Immunophenotyping (CD3/CD19/HLA-DR, CD4/CD8 and CD16/CD56 combinations) was performed using EDTA-anticoagulated blood, automated CD-Sapphire analysis and subsequent software processing. Of 35 samples from younger (<12 years) patients, 22 (63%) had nonspecific lymphocyte changes, 4 (11%) showed specific increases in nonreactive T-Helper or T-Suppressor cells, and five showed a reactive T-cell lymphocytosis. The remaining four were classified as 'Transient/Persistent NK-associated (NKa) Expansion' (n = 3) and specific B-cell lymphocytosis (n = 1). For older patients (n = 59), 15 (25%) had an increase (>1.5 x 10(9)/l) in B-cells, and seven investigated for surface immunoglobulin expression were all found to be clonal. The remaining samples were categorized as 'Transient/Persistent NK-associated (NKa) Expansion' (13/59), Reactive Lymphocytosis (5/59), 'Reactive Lymphocytosis or Transient/Persistent NKa Expansion' (8/59), specific T-Helper cell (n = 8) or T-Suppressor cell (n = 3) lymphocytosis, and 'Lymphocytosis of Undetermined Significance' (n = 7). This study has demonstrated the feasibility of applying limited immunophenotyping protocols to the investigation of patients with abnormal lymphocyte counts in routine haematology. By using commercially purchased liquid monoclonal reagents to determine lymphocyte subpopulation profiles, haematology laboratories can provide more definitive information of potential clinical importance.

  9. External evaluation of the Dimension Vista 1500® intelligent lab system.

    PubMed

    Bruneel, Arnaud; Dehoux, Monique; Barnier, Anne; Boutten, Anne

    2012-09-01

    Dimension Vista® analyzer combines four technologies (photometry, nephelometry, V-LYTE® integrated multisensor potentiometry, and LOCI® chemiluminescence) into one high-throughput system. We assessed analytical performance of assays routinely performed in our emergency laboratory according to the VALTEC protocol, and practicability. Precision was good for most parameters. Analytical domain was large and suitable for undiluted analysis in most clinical settings encountered in our hospital. Data were comparable and correlated to our routine analyzers (Roche Modular DP®, Abbott AXSYM®, Siemens Dimension® RxL, and BN ProSpec®). Performance of nephelometric and LOCI modules was excellent. Functional sensitivity of high-sensitivity C-reactive protein and cardiac troponin I were 0.165 mg/l and 0.03 ng/ml, respectively (coefficient of variation; CV < 10%). The influence of interfering substances (i.e., hemoglobin, bilirubin, or lipids) was moderate, and Dimension Vista® specifically alerted for interference according to HIL (hemolysis, icterus, lipemia) indices. Good instrument performance and full functionality (no reagent or sample carryover in the conditions evaluated, effective sample-volume detection, and clot detection) were confirmed. Simulated routine testing demonstrated excellent practicability, throughput, ease of use of software and security. Performance and practicability of Dimension Vista® are highly suitable for both routine and emergency use. Since no volume detection and thus no warning is available on limited sample racks, pediatric samples require special caution to the Siemens protocol to be analyzed in secured conditions. Our experience in routine practice is also discussed, i.e., the impact of daily workload, "manual" steps resulting from dilutions and pediatric samples, maintenances, flex hydration on instrument's performance on throughput and turnaround time. © 2012 Wiley Periodicals, Inc.

  10. Evaluation of the kinase domain of c-KIT in canine cutaneous mast cell tumors

    PubMed Central

    Webster, Joshua D; Kiupel, Matti; Yuzbasiyan-Gurkan, Vilma

    2006-01-01

    Background Mutations in the c-KIT proto-oncogene have been implicated in the progression of several neoplastic diseases, including gastrointestinal stromal tumors and mastocytosis in humans, and cutaneous mast cell tumors (MCTs) in canines. Mutations in human mastocytosis patients primarily occur in c-KIT exon 17, which encodes a portion of its kinase domain. In contrast, deletions and internal tandem duplication (ITD) mutations are found in the juxtamembrane domain of c-KIT in approximately 15% of canine MCTs. In addition, ITD c-KIT mutations are significantly associated with aberrant KIT protein localization in canine MCTs. However, some canine MCTs have aberrant KIT localization but lack ITD c-KIT mutations, suggesting that other mutations or other factors may be responsible for aberrant KIT localization in these tumors. Methods In order to characterize the prevalence of mutations in the phospho-transferase portion of c-KIT's kinase domain in canine MCTs exons 16–20 of 33 canine MCTs from 33 dogs were amplified and sequenced. Additionally, in order to determine if mutations in c-KIT exon 17 are responsible for aberrant KIT localization in MCTs that lack juxtamembrane domain c-KIT mutations, c-KIT exon 17 was amplified and sequenced from 18 canine MCTs that showed an aberrant KIT localization pattern but did not have ITD c-KIT mutations. Results No mutations or polymorphisms were identified in exons 16–20 of any of the MCTs examined. Conclusion In conclusion, mutations in the phospho-transferase portion of c-KIT's kinase domain do not play an important role in the progression of canine cutaneous MCTs, or in the aberrant localization of KIT in canine MCTs. PMID:16579858

  11. Adult cardiac stem cells are multipotent and robustly myogenic: c-kit expression is necessary but not sufficient for their identification.

    PubMed

    Vicinanza, Carla; Aquila, Iolanda; Scalise, Mariangela; Cristiano, Francesca; Marino, Fabiola; Cianflone, Eleonora; Mancuso, Teresa; Marotta, Pina; Sacco, Walter; Lewis, Fiona C; Couch, Liam; Shone, Victoria; Gritti, Giulia; Torella, Annalaura; Smith, Andrew J; Terracciano, Cesare Mn; Britti, Domenico; Veltri, Pierangelo; Indolfi, Ciro; Nadal-Ginard, Bernardo; Ellison-Hughes, Georgina M; Torella, Daniele

    2017-12-01

    Multipotent adult resident cardiac stem cells (CSCs) were first identified by the expression of c-kit, the stem cell factor receptor. However, in the adult myocardium c-kit alone cannot distinguish CSCs from other c-kit-expressing (c-kit pos ) cells. The adult heart indeed contains a heterogeneous mixture of c-kit pos cells, mainly composed of mast and endothelial/progenitor cells. This heterogeneity of cardiac c-kit pos cells has generated confusion and controversy about the existence and role of CSCs in the adult heart. Here, to unravel CSC identity within the heterogeneous c-kit-expressing cardiac cell population, c-kit pos cardiac cells were separated through CD45-positive or -negative sorting followed by c-kit pos sorting. The blood/endothelial lineage-committed (Lineage pos ) CD45 pos c-kit pos cardiac cells were compared to CD45 neg (Lineage neg /Lin neg ) c-kit pos cardiac cells for stemness and myogenic properties in vitro and in vivo. The majority (~90%) of the resident c-kit pos cardiac cells are blood/endothelial lineage-committed CD45 pos CD31 pos c-kit pos cells. In contrast, the Lin neg CD45 neg c-kit pos cardiac cell cohort, which represents ⩽10% of the total c-kit pos cells, contain all the cardiac cells with the properties of adult multipotent CSCs. These characteristics are absent from the c-kit neg and the blood/endothelial lineage-committed c-kit pos cardiac cells. Single Lin neg c-kit pos cell-derived clones, which represent only 1-2% of total c-kit pos myocardial cells, when stimulated with TGF-β/Wnt molecules, acquire full transcriptome and protein expression, sarcomere organisation, spontaneous contraction and electrophysiological properties of differentiated cardiomyocytes (CMs). Genetically tagged cloned progeny of one Lin neg c-kit pos cell when injected into the infarcted myocardium, results in significant regeneration of new CMs, arterioles and capillaries, derived from the injected cells. The CSC's myogenic regenerative capacity is dependent on commitment to the CM lineage through activation of the SMAD2 pathway. Such regeneration was not apparent when blood/endothelial lineage-committed c-kit pos cardiac cells were injected. Thus, among the cardiac c-kit pos cell cohort only a very small fraction has the phenotype and the differentiation/regenerative potential characteristics of true multipotent CSCs.

  12. Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.

    PubMed

    Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H

    2017-12-12

    Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.

  13. Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method

    PubMed Central

    Baker, Harold N.; Murphy, Robin; Lopez, Erica; Garcia, Carlos

    2012-01-01

    The enzyme-linked immunosorbent assay (ELISA) has long been the primary tool for detection of analytes of interest in biological samples for both life science research and clinical diagnostics. However, ELISA has limitations. It is typically performed in a 96-well microplate, and the wells are coated with capture antibody, requiring a relatively large amount of sample to capture an antigen of interest . The large surface area of the wells and the hydrophobic binding of capture antibody can also lead to non-specific binding and increased background. Additionally, most ELISAs rely upon enzyme-mediated amplification of signal in order to achieve reasonable sensitivity. Such amplification is not always linear and can thus skew results. In the past 15 years, a new technology has emerged that offers the benefits of the ELISA, but also enables higher throughput, increased flexibility, reduced sample volume, and lower cost, with a similar workflow 1, 2. Luminex xMAP Technology is a microsphere (bead) array platform enabling both monoplex and multiplex assays that can be applied to both protein and nucleic acid applications 3-5. The beads have the capture antibody covalently immobilized on a smaller surface area, requiring less capture antibody and smaller sample volumes, compared to ELISA, and non-specific binding is significantly reduced. Smaller sample volumes are important when working with limiting samples such as cerebrospinal fluid, synovial fluid, etc. 6. Multiplexing the assay further reduces sample volume requirements, enabling multiple results from a single sample. Recent improvements by Luminex include: the new MAGPIX system, a smaller, less expensive, easier-to-use analyzer; Low-Concentration Magnetic MagPlex Microspheres which eliminate the need for expensive filter plates and come in a working concentration better suited for assay development and low-throughput applications; and the xMAP Antibody Coupling (AbC) Kit, which includes a protocol, reagents, and consumables necessary for coupling beads to the capture antibody of interest. (See Materials section for a detailed list of kit contents.) In this experiment, we convert a pre-optimized ELISA assay for TNF-alpha cytokine to the xMAP platform and compare the performance of the two methods 7-11. TNF-alpha is a biomarker used in the measurement of inflammatory responses in patients with autoimmune disorders. We begin by coupling four candidate capture antibodies to four different microsphere sets or regions. When mixed together, these four sets allow for the simultaneous testing of all four candidates with four separate detection antibodies to determine the best antibody pair, saving reagents, sample and time. Two xMAP assays are then constructed with the two most optimal antibody pairs and their performance is compared to that of the original ELISA assay in regards to signal strength, dynamic range, and sensitivity. PMID:22806215

  14. Receptor tyrosine kinase (c-Kit) inhibitors: a potential therapeutic target in cancer cells

    PubMed Central

    Abbaspour Babaei, Maryam; Kamalidehghan, Behnam; Saleem, Mohammad; Huri, Hasniza Zaman; Ahmadipour, Fatemeh

    2016-01-01

    c-Kit, a receptor tyrosine kinase, is involved in intracellular signaling, and the mutated form of c-Kit plays a crucial role in occurrence of some cancers. The function of c-Kit has led to the concept that inhibiting c-Kit kinase activity can be a target for cancer therapy. The promising results of inhibition of c-Kit for treatment of cancers have been observed in some cancers such as gastrointestinal stromal tumor, acute myeloid leukemia, melanoma, and other tumors, and these results have encouraged attempts toward improvement of using c-Kit as a capable target for cancer therapy. This paper presents the findings of previous studies regarding c-Kit as a receptor tyrosine kinase and an oncogene, as well as its gene targets and signaling pathways in normal and cancer cells. The c-Kit gene location, protein structure, and the role of c-Kit in normal cell have been discussed. Comprehending the molecular mechanism underlying c-Kit-mediated tumorogenesis is consequently essential and may lead to the identification of future novel drug targets. The potential mechanisms by which c-Kit induces cellular transformation have been described. This study aims to elucidate the function of c-Kit for future cancer therapy. In addition, it has c-Kit inhibitor drug properties and their functions have been listed in tables and demonstrated in schematic pictures. This review also has collected previous studies that targeted c-Kit as a novel strategy for cancer therapy. This paper further emphasizes the advantages of this approach, as well as the limitations that must be addressed in the future. Finally, although c-Kit is an attractive target for cancer therapy, based on the outcomes of treatment of patients with c-Kit inhibitors, it is unlikely that Kit inhibitors alone can lead to cure. It seems that c-Kit mutations alone are not sufficient for tumorogenesis, but do play a crucial role in cancer occurrence. PMID:27536065

  15. Troubleshooting fermentation in corn wet milling ethanol production

    USDA-ARS?s Scientific Manuscript database

    To convert starch to ethanol, continuous fermentation processes are employed by corn wet milling plants all over world. Contaminations by bacterial microorganisms like Lactobacillus and wild yeasts like Brettanomyces are common and result in lower ethanol yields (Abbott and Ingledew 2005, Skinner an...

  16. A Raven in a Coal Scuttle: Theodore Roosevelt & the Animal Coloration Controversy.

    ERIC Educational Resources Information Center

    Hendrick, Robert

    1995-01-01

    Recounts a debate between Theodore Roosevelt and Abbott Thayer in 1909-12 over whether animal coloration was an adaptation resulting from natural selection or whether the animal's environment acted directly on it to form its color patterns. (ZWH)

  17. SHP-1 Binds and Negatively Modulates the c-Kit Receptor by Interaction with Tyrosine 569 in the c-Kit Juxtamembrane Domain

    PubMed Central

    Kozlowski, Maya; Larose, Louise; Lee, Fai; Le, Duc Mingh; Rottapel, Robert; Siminovitch, Katherine A.

    1998-01-01

    The SH2 domain-containing SHP-1 tyrosine phosphatase has been shown to negatively regulate a broad spectrum of growth factor- and cytokine-driven mitogenic signaling pathways. Included among these is the cascade of intracellular events evoked by stem cell factor binding to c-Kit, a tyrosine kinase receptor which associates with and is dephosphorylated by SHP-1. Using a series of glutathione S-transferase (GST) fusion proteins containing either tyrosine-phosphorylated segments of the c-Kit cytosolic region or the SH2 domains of SHP-1, we have shown that SHP-1 interacts with c-Kit by binding selectively to the phosphorylated c-Kit juxtamembrane region and that the association of c-Kit with the larger of the two SHP-1 isoforms may be mediated through either the N-terminal or C-terminal SHP-1 SH2 domain. The results of binding assays with mutagenized GST-Kit juxtamembrane fusion proteins and competitive inhibition assays with phosphopeptides encompassing each c-Kit juxtamembrane region identified the tyrosine residue at position 569 as the major site for binding of SHP-1 to c-Kit and suggested that tyrosine 567 contributes to, but is not required for, this interaction. By analysis of Ba/F3 cells retrovirally transduced to express c-Kit receptors, phenylalanine substitution of c-Kit tyrosine residue 569 was shown to be associated with disruption of c-Kit–SHP-1 binding and induction of hyperproliferative responses to stem cell factor. Although phenylalanine substitution of c-Kit tyrosine residue 567 in the Ba/F3–c-Kit cells did not alter SHP-1 binding to c-Kit, the capacity of a second c-Kit-binding tyrosine phosphatase, SHP-2, to associate with c-Kit was markedly reduced, and the cells again showed hyperproliferative responses to stem cell factor. These data therefore identify SHP-1 binding to tyrosine 569 on c-Kit as an interaction pivotal to SHP-1 inhibitory effects on c-Kit signaling, but they indicate as well that cytosolic protein tyrosine phosphatases other than SHP-1 may also negatively regulate the coupling of c-Kit engagement to proliferation. PMID:9528781

  18. Comparison of three DNA extraction kits to establish maximum yield and quality of coral-associated microbial DNA

    USGS Publications Warehouse

    Baker, Erin J.; Kellogg, Christina A.

    2014-01-01

    Coral microbiology is an expanding field, yet there is no standard DNA extraction protocol. Although many researchers depend on commercial extraction kits, no specific kit has been optimized for use with coral samples. Both soil and plant DNA extraction kits from MO BIO Laboratories, Inc., have been used by many research groups for this purpose. MO BIO recently replaced their PowerPlant® kit with an improved PowerPlantPro kit, but it was unclear how these changes would affect the kit’s use with coral samples. In order to determine which kit produced the best results, we conducted a comparison between the original PowerPlant kit, the new PowerPlantPro kit, and an alternative kit, PowerSoil, using samples from several different coral genera. The PowerPlantPro kit had the highest DNA yields, but the lack of 16S rRNA gene amplification in many samples suggests that much of the yield may be coral DNA rather than microbial DNA. The most consistent positive amplifications came from the PowerSoil kit.

  19. [Evaluation of Postoperative Astigmatism Correction and Postoperative Rotational Stability of Two Toric Intraocular Lenses].

    PubMed

    Grohlich, M; Miháltz, K; Lasta, M; Weingessel, B; Vécsei-Marlovits, V

    2017-06-01

    Background The aim of this retrospective study was to evaluate the rotational stability and the refractive outcome of two different toric IOLs. Methods This study included 41 eyes with corneal astigmatism greater than 1.5 diopters (D). All patients underwent surgery in the Department of Ophthalmology at Hietzing Hospital between 2010 and 2013. The study lenses were the Alcon AcrySof IQ Toric IOL and the Abbott Tecnis Toric Aspheric IOL. Measurements of corneal topography and aberrations were performed with the HOYA iTrace™. Determination of visual acuity was performed with ETDRS charts. Optical aberrations were represented by Zernike coefficients, and optical quality was assessed with the Strehl ratio. Results Mean rotation was 4.92° (standard deviation: ± 4.10°) in the Alcon group and 4.31° (± 4.59°) in the Abbott group. No significant difference was observed between the two toric intraocular lenses. Rotational stability was comparable to results from other studies. Astigmatism correction was visualised with a power-vector analysis, which demonstrated similar results in both lenses and a clear success of astigmatism correction. No statistically significant differences were found in residual refractive astigmatism, which was 0.85 ± 0.48 D in the Alcon group and 1.09 ± 0.66 in the Tecnis group. No significant difference between the two groups was found in the Strehl ratio. Conclusion Implantation of toric intraocular lenses (Alcon + Abbott) in patients with regular astigmatism is an effective and safe method, which should be offered to patients. Both the Tecnis and the AcrySof toric IOLs similarly reduced ocular astigmatism. Georg Thieme Verlag KG Stuttgart · New York.

  20. Performance of an Early Infant Diagnostic Test, AmpliSens DNA-HIV-FRT, Using Dried Blood Spots Collected from Children Born to Human Immunodeficiency Virus-Infected Mothers in Ukraine

    PubMed Central

    Shanmugam, Vedapuri; Azarskova, Marianna; Nguyen, Shon; Hurlston, Mackenzie; Sabatier, Jennifer; Zhang, Guoqing; Osmanov, Saladin; Ellenberger, Dennis; Yang, Chunfu; Vitek, Charles; Liulchuk, Maria; Nizova, Natalya

    2015-01-01

    An accurate accessible test for early infant diagnosis (EID) is crucial for identifying HIV-infected infants and linking them to treatment. To improve EID services in Ukraine, dried blood spot (DBS) samples obtained from 237 HIV-exposed children (≤18 months of age) in six regions in Ukraine in 2012 to 2013 were tested with the AmpliSens DNA-HIV-FRT assay, the Roche COBAS AmpliPrep/COBAS TaqMan (CAP/CTM) HIV-1 Qual test, and the Abbott RealTime HIV-1 Qualitative assay. In comparison with the paired whole-blood results generated from AmpliSens testing at the oblast HIV reference laboratories in Ukraine, the sensitivity was 0.99 (95% confidence interval [CI], 0.95 to 1.00) for the AmpliSens and Roche CAP/CTM Qual assays and 0.96 (95% CI, 0.90 to 0.98) for the Abbott Qualitative assay. The specificity was 1.00 (95% CI, 0.97 to 1.00) for the AmpliSens and Abbott Qualitative assays and 0.99 (95% CI, 0.96 to 1.00) for the Roche CAP/CTM Qual assay. McNemar analysis indicated that the proportions of positive results for the tests were not significantly different (P > 0.05). Cohen's kappa (0.97 to 0.99) indicated almost perfect agreement among the three tests. These results indicated that the AmpliSens DBS and whole-blood tests performed equally well and were comparable to the two commercially available EID tests. More importantly, the performance characteristics of the AmpliSens DBS test meets the World Health Organization EID test requirements; implementing AmpliSens DBS testing might improve EID services in resource-limited settings. PMID:26447114

  1. Measurement of immature platelets with Abbott CD-Sapphire and Sysmex XE-5000 in haematology and oncology patients.

    PubMed

    Meintker, Lisa; Haimerl, Maria; Ringwald, Jürgen; Krause, Stefan W

    2013-11-01

    Measurement of immature platelets was introduced into routine diagnostics by Sysmex as immature platelet fraction (IPF) some years ago and recently by Abbott as reticulated platelet fraction (rPT). Here, we compare both methods. We evaluated the precision and agreement of these parameters between Sysmex XE-5000 and Abbott CD-Sapphire in three distinct thrombocytopaenic cohorts: 30 patients with beginning thrombocytopaenia and 64 patients with recovering platelets (PLT) after chemotherapy, 16 patients with immune thrombocytopaenia (ITP) or heparin-induced thrombocytopaenia type 2 (HIT) and 110 additional normal controls. Furthermore, we analysed, how IPF/rPT differed between these thrombocytopaenic cohorts and controls. Both analysers demonstrated acceptable overall precision (repeatability) of IPF/rPT with lower precision at low PLT counts. IPF/rPT artificially increased during storage of blood samples overnight. Inter-instrument comparison showed a moderate correlation (Pearson r²=0.38) and a systematic bias of 1.04 towards higher IPF-values with the XE-5000. IPF/rPT was highest in recovering thrombopoesis after chemotherapy and moderately increased in ITP/HIT. The normal range deduced from control samples was much narrower with CD-Sapphire (1.0%-3.8%, established here for the first time) in comparison to XE-5000 (0.8%-7.9%) leading to a smaller overlap of samples with increased PLT turnover and normal controls. IPF and rPT both give useful information on PLT turnover, although the two analysers only show a moderate inter-instrument correlation and have different reference ranges. A better separation of patient groups with high PLT turnover like ITP/HIT from normal controls is obtained by CD-Sapphire.

  2. Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers.

    PubMed

    Nikolac Gabaj, Nora; Miler, Marijana; Vrtarić, Alen; Hemar, Marina; Filipi, Petra; Kocijančić, Marija; Šupak Smolčić, Vesna; Ćelap, Ivana; Šimundić, Ana-Maria

    2018-04-25

    The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.

  3. Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments.

    PubMed

    Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O

    2014-06-01

    Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.

  4. Comparison of cardiac TnI outliers using a contemporary and a high-sensitivity assay on the Abbott Architect platform.

    PubMed

    Ryan, J B; Southby, S J; Stuart, L A; Mackay, R; Florkowski, C M; George, P M

    2014-07-01

    Assays for cardiac troponin (cTn) have undergone improvements in sensitivity and precision in recent years. Increased rates of outliers, however, have been reported on various cTn platforms, typically giving irreproducible, falsely higher results. We aimed to evaluate the outlier rate occurring in patients with elevated cTnI using a contemporary and high-sensitivity assay. All patients with elevated cTnI (up to 300 ng/L) performed over a 21-month period were assayed in duplicate. A contemporary assay (Abbott STAT Troponin-I) was used for the first part of the study and subsequently a high-sensitivity assay (Abbott STAT High-Sensitive Troponin-I) was used. Outliers exceeded a calculated critical difference (CD) (CD = z × √2 × SDAnalytical) where z = 3.5 (for probability of 0.0005) and critical outliers also were on a different side of the decision level. The respective outlier and critical outlier rates were 0.22% and 0.10% for the contemporary assay (n = 4009) and 0.18% and 0.13% for the high-sensitivity assay (n = 3878). There was no significant reduction in outlier rate between the two assays (χ(2) = 0.034, P = 0.854). Fifty-six percent of outliers occurred in samples where cTn was an 'add-on' test (and was stored and refrigerated prior to assay). Despite recent improvements in cTn methods, outliers (including critical outliers) still occur at a low rate in both a contemporary and high-sensitivity cTnI assay. Laboratory and clinical staff should be aware of this potential analytical error, particularly in samples with suboptimal sample handling such as add-on tests. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit.

    PubMed

    Gijzen, Karlijn; Moolenaar, David L J; Weusten, Jos J A M; Pluim, Hendrik J; Demir, Ayse Y

    2012-11-01

    Implementation of tight glycemic control (TGC) and avoidance of hypoglycemia in intensive care unit (ICU) patients require frequent analysis of blood glucose. This can be achieved by accurate point-of-care (POC) hospital-use glucose meters. In this study one home-use and four different hospital-use POC glucose meters were evaluated in critically ill ICU patients. All patients (n = 80) requiring TGC were included in this study. For each patient three to six glucose measurements (n = 390) were performed. Blood glucose was determined by four hospital-use POC glucose meters, Roche Accu-Check Inform II System, HemoCue Glu201DM, Nova StatStrip, Abbott Precision Xceed Pro, and one home-use POC glucose meter, Menarini GlucoCard Memory PC. The criteria described in ISO 15197, Dutch TNO quality guideline and in NACB/ADA-2011 were applied in the comparisons. According to the ISO 15197, the percentages of the measured values that fulfilled the criterion were 99.5% by Roche, 95.1% by HemoCue, 91.0% by Nova, 96.6% by Abbott, and 63.3% by Menarini. According to the TNO quality guideline these percentages were 96.1% , 91.0% , 81.8% , 94.2% , and 47.7% , respectively. Application of the NACB/ADA guideline resulted in percentages of 95.6%, 89.2%, 77.9%, 93.4%, and 45.4%, respectively. When ISO 15197 was applied, Roche, HemoCue and Abbott fulfilled the criterion in this patient population, whereas Nova and Menarini did not. However, when TNO quality guideline and NACB/ADA 2011 guideline were applied only Roche fulfilled the criteria.

  6. Back to the future! Revisiting the physiological cost of negative work as a team-based activity for exercise physiology students.

    PubMed

    Kilgas, Matthew A; Elmer, Steven J

    2017-03-01

    We implemented a team-based activity in our exercise physiology teaching laboratory that was inspired from Abbott et al.'s classic 1952 Journal of Physiology paper titled "The physiological cost of negative work." Abbott et al. connected two bicycles via one chain. One person cycled forward (muscle shortening contractions, positive work) while the other resisted the reverse moving pedals (muscle lengthening contractions, negative work), and the cost of work was compared. This study was the first to link human whole body energetics with isolated muscle force-velocity characteristics. The laboratory activity for our students ( n = 35) was designed to reenact Abbott et al.'s experiment, integrate previously learned techniques, and illustrate differences in physiological responses to muscle shortening and lengthening contractions. Students (11-12 students/laboratory section) were split into two teams (positive work vs. negative work). One student from each team volunteered to cycle against the other for ~10 min. The remaining students in each team were tasked with measuring: 1 ) O 2 consumption, 2 ) heart rate, 3 ) blood lactate, and 4 ) perceived exertion. Students discovered that O 2 consumption during negative work was about one-half that of positive work and all other physiological parameters were also substantially lower. Muscle lengthening contractions were discussed and applied to rehabilitation and sport training. The majority of students (>90%) agreed or strongly agreed that they stayed engaged during the activity and it improved their understanding of exercise physiology. All students recommended the activity be performed again. This activity was engaging, emphasized teamwork, yielded clear results, was well received, and preserved the history of classic physiological experiments. Copyright © 2017 the American Physiological Society.

  7. Clinical utility of the ARCHITECT HCV Ag assay for early treatment monitoring in patients with chronic hepatitis C genotype 1 infection.

    PubMed

    Vermehren, Johannes; Susser, Simone; Berger, Annemarie; Perner, Dany; Peiffer, Kai-Henrik; Allwinn, Regina; Zeuzem, Stefan; Sarrazin, Christoph

    2012-09-01

    Virologic response-monitoring is essential for determining therapy duration in patients with chronic hepatitis C virus (HCV) infection. This is usually performed using highly sensitive HCV-RNA assays. However, HCV-RNA assays are time-consuming, expensive and require highly trained personnel. Quantitative determination of HCV core-antigen (HCVAg) levels may be used to supplement treatment monitoring. The clinical utility of the ARCHITECT HCV Ag assay (Abbott Diagnostics) for response-guided therapy was investigated. We analyzed serum from 160 patients with HCV genotype 1 infection who had been treated with peg-interferon alfa-2b/ribavirin. HCVAg levels were determined at baseline, weeks 1, 2, 4 and 12. HCVAg levels were compared to those obtained with HCV-RNA assays: VERSANT HCV Quantitative 3.0 (bDNA) and Qualitative (TMA, both Siemens Healthcare) assay and the Abbott RealTime HCV assay (ART; Abbott Diagnostics). Baseline HCVAg levels correlated well with HCV-RNA as assessed by bDNA (r=0.91; p<0.0001) and ART (r=0.92; p<0.0001), respectively. Patients with undetectable HCVAg levels at week 1 had a 90.9% probability (positive predictive value) to achieve a rapid virologic response (HCV-RNA undetectable at week 4) based on TMA and 86.4% based on ART, respectively. Patients with less than 1 log(10) reduction in HCVAg between baseline and week 12 had a 90% probability (negative predictive value) to achieve a nonresponse (<2 log(10) decline in HCV-RNA between baseline and week 12) based on bDNA and 100% based on ART, respectively. Determination of HCVAg may be useful for antiviral response-monitoring in patients with HCV genotype 1 infection. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Evaluation of performance across the dynamic range of the Abbott RealTime HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses.

    PubMed

    Swanson, Priscilla; Huang, Shihai; Abravaya, Klara; de Mendoza, Carmen; Soriano, Vincent; Devare, Sushil G; Hackett, John

    2007-04-01

    Performance of the Abbott m2000 instrument system and the Abbott RealTime HIV-1 assay was evaluated using a panel of 37 group M (subtypes A-D, F, G, CRF01_AE, CRF02_AG and unique recombinant forms) and 2 group O virus isolates. Testing was performed on 273 sample dilutions and compared to VERSANT HIV-1 RNA 3.0 (bDNA) and AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5) test results. RealTime HIV-1, bDNA, and Monitor v1.5 tests quantified 87%, 78%, and 81% of samples, respectively. RealTime HIV-1 detected an additional 31 samples at < 40 copies/mL. For group M, RealTime HIV-1 dilution profiles and viral loads were highly correlated with bDNA and Monitor v1.5 values; 87% and 89% of values were within 0.5 log(10) copies/mL. In contrast, the group O viruses were not detected by Monitor v1.5 and were substantially underquantified by approximately 2 log(10) copies/mL in bDNA relative to the RealTime HIV-1 assay. Sequence analysis revealed that RealTime HIV-1 primer/probe binding sites are highly conserved and exhibit fewer nucleotide mismatches relative to Monitor v1.5. The automated m2000 system and RealTime HIV-1 assay offer the advantages of efficient sample processing and throughput with reduced "hands-on" time while providing improved sensitivity, expanded dynamic range and reliable quantification of genetically diverse HIV-1 strains.

  9. Evaluating Laboratory Performance on Point-of-Care Glucose Testing with Six Sigma Metric for 151 Institutions in China.

    PubMed

    Fei, Yang; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-10-01

    The aim of this study was to use Six Sigma(SM) (Motorola Trademark Holdings, Libertyville, IL) techniques to analyze the quality of point-of-care (POC) glucose testing measurements quantitatively and to provide suggestions for improvement. In total, 151 laboratories in China were included in this investigation in 2014. Bias and coefficient of variation were collected from an external quality assessment and an internal quality control program, respectively, for POC glucose testing organized by the National Center for Clinical Laboratories. The σ values and the Quality Goal Index were used to evaluate the performance of POC glucose meters. There were 27, 30, 57, and 37 participants in the groups using Optium Xceed™ (Abbott Diabetes Care, Alameda, CA), Accu-Chek(®) Performa (Roche, Basel, Switzerland), One Touch Ultra(®) (Abbott), and "other" meters, respectively. The median of the absolute value of percentage difference varied among different lots and different groups. Among all the groups, the Abbott One Touch Ultra group had the smallest median of absolute value of percentage difference except for lot 201411, whereas the "other" group had the largest median in all five lots. More than 85% of participate laboratories satisfied the total allowable error (TEa) requirement in International Organization for Standardization standard 15197:2013, and 85.43% (129/151) of laboratories obtained intralaboratory coefficient of variations less than 1/3TEa. However, Six Sigma techniques suggested that 41.72% (63/151) to 65.56% (99/151) of the laboratories needed to improve their POC glucose testing performance, in either precision, trueness, or both. Laboratories should pay more attention on the practice of POC glucose testing and take actions to improve their performance. Only in this way can POC glucose testing really function well in clinical practice.

  10. Evaluating lubricating capacity of vegetal oils using Abbott-Firestone curve

    NASA Astrophysics Data System (ADS)

    Georgescu, C.; Cristea, G. C.; Dima, C.; Deleanu, L.

    2017-02-01

    The paper presents the change of functional parameters defined on the Abbott-Firestone curve in order to evaluate the surface quality of the balls from the four ball tester, after tests done with several vegetable oils. The tests were done using two grades of rapeseed oil (degummed and refined) and two grades of soybean oil (coarse and degummed) and a common transmission oil (T90). Test parameters were 200 N and 0.576 m/s (1500 rpm) for 60 minutes. For the refined rapeseed oil, the changes in shape of the Abbott-Firestone curves are more dramatic, these being characterized by high values of Spk (the average value for the wear scars on the three balls), thus being 40% of the sum Svk + Sk + Spk, percentage also obtained for the soybean oil, but the value Spk being lower. For the degummed soybean oil, the profile height of the wear scars are taller than those obtained after testing the coarse soybean oil, meaning that the degumming process has a negative influence on the worn surface quality and the lubricating capacity of this oil. Comparing the surface quality of the wear scars on fixed tested balls is a reliable method to point out the lubricant properties of the vegetable oils, especially if they are compared to a “classical” lubricant as a non-additivated transmission mineral oil T90. The best surface after testing was obtained for the soybean oil, followed by T90 oil and the degummed grades of the soybean oil and rapeseed oil (these three giving very close values for the functional parameters), but the refined rapeseed oil generated the poorest quality of the wear scars on the balls, under the same testing conditions.

  11. Transference of CALIPER pediatric reference intervals to biochemical assays on the Roche cobas 6000 and the Roche Modular P.

    PubMed

    Higgins, Victoria; Chan, Man Khun; Nieuwesteeg, Michelle; Hoffman, Barry R; Bromberg, Irvin L; Gornall, Doug; Randell, Edward; Adeli, Khosrow

    2016-01-01

    The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) has recently established pediatric age- and sex-specific reference intervals for over 85 biochemical markers on the Abbott Architect system. Previously, CALIPER reference intervals for several biochemical markers were successfully transferred from Abbott assays to Roche, Beckman, Ortho, and Siemens assays. This study further broadens the CALIPER database by performing transference and verification for 52 biochemical assays on the Roche cobas 6000 and the Roche Modular P. Using CLSI C28-A3 and EP9-A2 guidelines, transference of the CALIPER reference intervals was attempted for 16 assays on the Roche cobas 6000 and 36 on the Modular P. Calculated reference intervals were further verified using 100 healthy CALIPER samples. Most assays showed strong correlation between assay systems and were transferable from Abbott to the Roche cobas 6000 (81%) and the Modular P (86%). Bicarbonate and magnesium were not transferable on either system and calcium and prealbumin were not transferable to the Modular P. Of the transferable analytes, 62% and 61% were verified on the cobas 6000 and the Modular P, respectively. This study extends the utility of the CALIPER database to two additional analytical systems, which facilitates the broad application of CALIPER reference intervals at pediatric centers utilizing Roche biochemical assays. Transference studies across different analytical platforms can later be collectively analyzed in an attempt to develop common reference intervals across all clinical chemistry instruments to harmonize laboratory test interpretation in diagnosis and monitoring of pediatric disease. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.

    PubMed

    Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A

    2013-12-01

    With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Identification of mutations in the coding sequence of the proto-oncogene c-kit in a human mast cell leukemia cell line causing ligand-independent activation of c-kit product.

    PubMed Central

    Furitsu, T; Tsujimura, T; Tono, T; Ikeda, H; Kitayama, H; Koshimizu, U; Sugahara, H; Butterfield, J H; Ashman, L K; Kanayama, Y

    1993-01-01

    The c-kit proto-oncogene encodes a receptor tyrosine kinase. Binding of c-kit ligand, stem cell factor (SCF) to c-kit receptor (c-kitR) is known to activate c-kitR tyrosine kinase, thereby leading to autophosphorylation of c-kitR on tyrosine and to association of c-kitR with substrates such as phosphatidylinositol 3-kinase (PI3K). In a human mast cell leukemia cell line HMC-1, c-kitR was found to be constitutively phosphorylated on tyrosine, activated, and associated with PI3K without the addition of SCF. The expression of SCF mRNA transcript in HMC-1 cells was not detectable by means of PCR after reverse transcription (RT-PCR) analysis, suggesting that the constitutive activation of c-kitR was ligand independent. Sequencing of whole coding region of c-kit cDNA revealed that c-kit genes of HMC-1 cells were composed of a normal, wild-type allele and a mutant allele with two point mutations resulting in intracellular amino acid substitutions of Gly-560 for Val and Val-816 for Asp. Amino acid sequences in the regions of the two mutations are completely conserved in all of mouse, rat, and human c-kit. In order to determine the causal role of these mutations in the constitutive activation, murine c-kit mutants encoding Gly-559 and/or Val-814, corresponding to human Gly-560 and/or Val-816, were constructed by site-directed mutagenesis and expressed in a human embryonic kidney cell line, 293T cells. In the transfected cells, both c-kitR (Gly-559, Val-814) and c-kitR (Val-814) were abundantly phosphorylated on tyrosine and activated in immune complex kinase reaction in the absence of SCF, whereas tyrosine phosphorylation and activation of c-kitR (Gly-559) or wild-type c-kitR was modest or little, respectively. These results suggest that conversion of Asp-816 to Val in human c-kitR may be an activating mutation and responsible for the constitutive activation of c-kitR in HMC-1 cells. Images PMID:7691885

  14. Distinct cellular properties of oncogenic KIT receptor tyrosine kinase mutants enable alternative courses of cancer cell inhibition

    PubMed Central

    Shi, Xiarong; Sousa, Leiliane P.; Mandel-Bausch, Elizabeth M.; Tome, Francisco; Reshetnyak, Andrey V.; Hadari, Yaron; Schlessinger, Joseph; Lax, Irit

    2016-01-01

    Large genomic sequencing analysis as part of precision medicine efforts revealed numerous activating mutations in receptor tyrosine kinases, including KIT. Unfortunately, a single approach is not effective for inhibiting cancer cells or treating cancers driven by all known oncogenic KIT mutants. Here, we show that each of the six major KIT oncogenic mutants exhibits different enzymatic, cellular, and dynamic properties and responds distinctly to different KIT inhibitors. One class of KIT mutants responded well to anti-KIT antibody treatment alone or in combination with a low dose of tyrosine kinase inhibitors (TKIs). A second class of KIT mutants, including a mutant resistant to imatinib treatment, responded well to a combination of TKI with anti-KIT antibodies or to anti-KIT toxin conjugates, respectively. We conclude that the preferred choice of precision medicine treatments for cancers driven by activated KIT and other RTKs may rely on clear understanding of the dynamic properties of oncogenic mutants. PMID:27482095

  15. Megakaryocytes compensate for Kit insufficiency in murine arthritis.

    PubMed

    Cunin, Pierre; Penke, Loka R; Thon, Jonathan N; Monach, Paul A; Jones, Tatiana; Chang, Margaret H; Chen, Mary M; Melki, Imene; Lacroix, Steve; Iwakura, Yoichiro; Ware, Jerry; Gurish, Michael F; Italiano, Joseph E; Boilard, Eric; Nigrovic, Peter A

    2017-05-01

    The growth factor receptor Kit is involved in hematopoietic and nonhematopoietic development. Mice bearing Kit defects lack mast cells; however, strains bearing different Kit alleles exhibit diverse phenotypes. Herein, we investigated factors underlying differential sensitivity to IgG-mediated arthritis in 2 mast cell-deficient murine lines: KitWsh/Wsh, which develops robust arthritis, and KitW/Wv, which does not. Reciprocal bone marrow transplantation between KitW/Wv and KitWsh/Wsh mice revealed that arthritis resistance reflects a hematopoietic defect in addition to mast cell deficiency. In KitW/Wv mice, restoration of susceptibility to IgG-mediated arthritis was neutrophil independent but required IL-1 and the platelet/megakaryocyte markers NF-E2 and glycoprotein VI. In KitW/Wv mice, platelets were present in numbers similar to those in WT animals and functionally intact, and transfer of WT platelets did not restore arthritis susceptibility. These data implicated a platelet-independent role for the megakaryocyte, a Kit-dependent lineage that is selectively deficient in KitW/Wv mice. Megakaryocytes secreted IL-1 directly and as a component of circulating microparticles, which activated synovial fibroblasts in an IL-1-dependent manner. Transfer of WT but not IL-1-deficient megakaryocytes restored arthritis susceptibility to KitW/Wv mice. These findings identify functional redundancy among Kit-dependent hematopoietic lineages and establish an unanticipated capacity of megakaryocytes to mediate IL-1-driven systemic inflammatory disease.

  16. Signal transduction by normal isoforms and W mutant variants of the Kit receptor tyrosine kinase.

    PubMed

    Reith, A D; Ellis, C; Lyman, S D; Anderson, D M; Williams, D E; Bernstein, A; Pawson, T

    1991-09-01

    Germline mutations at the Dominant White Spotting (W) and Steel (Sl) loci have provided conclusive genetic evidence that c-kit mediated signal transduction pathways are essential for normal mouse development. We have analysed the interactions of normal and mutant W/c-kit gene products with cytoplasmic signalling proteins, using transient c-kit expression assays in COS cells. In addition to the previously identified c-kit gene product (Kit+), a second normal Kit isoform (KitA+) containing an in-frame insertion, Gly-Asn-Asn-Lys, within the extracellular domain, was detected in murine mast cell cultures and mid-gestation placenta. Both Kit+ and KitA+ isoforms showed increased autophosphorylation and enhanced association with phosphatidylinositol (PI) 3' kinase and PLC gamma 1, when stimulated with recombinant soluble Steel factor. No association or increase in phosphorylation of GAP and two GAP-associated proteins, p62 and p190, was observed. The two isoforms had distinct activities in the absence of exogenous soluble Steel factor; Kit+, but not KitA+, showed constitutive tyrosine phosphorylation that was accompanied by a low constitutive level of association with PI-3' kinase and PLC gamma 1. Introduction of the point substitutions associated with W37 (Glu582----Lys) or W41 (Val831----Met) mutant alleles into c-kit expression constructs abolished (W37) or reduced (W41) the Steel factor-induced association of the Kit receptor with signalling proteins in a manner proportional to the overall severity of the corresponding W mutant phenotype. These data suggest a diversity of normal Kit signalling pathways and indicate that W mutant phenotypes result from primary defects in the Kit receptor that affect its interaction with cytoplasmic signalling proteins.

  17. Production of latex agglutination reagents for pneumococcal serotyping

    PubMed Central

    2013-01-01

    Background The current ‘gold standard’ for serotyping pneumococci is the Quellung test. This technique is laborious and requires a certain level of training to correctly perform. Commercial pneumococcal latex agglutination serotyping reagents are available, but these are expensive. In-house production of latex agglutination reagents can be a cost-effective alternative to using commercially available reagents. This paper describes a method for the production and quality control (QC) of latex reagents, including problem solving recommendations, for pneumococcal serotyping. Results Here we describe a method for the production of latex agglutination reagents based on the passive adsorption of antibodies to latex particles. Sixty-five latex agglutination reagents were made using the PneuCarriage Project (PCP) method, of which 35 passed QC. The other 30 reagents failed QC due to auto-agglutination (n=2), no reactivity with target serotypes (n=8) or cross-reactivity with non-target serotypes (n=20). Dilution of antisera resulted in a further 27 reagents passing QC. The remaining three reagents passed QC when prepared without centrifugation and wash steps. Protein estimates indicated that latex reagents that failed QC when prepared using the PCP method passed when made with antiserum containing ≤ 500 μg/ml of protein. Sixty-one nasopharyngeal isolates were serotyped with our in-house latex agglutination reagents, with the results showing complete concordance with the Quellung reaction. Conclusions The method described here to produce latex agglutination reagents allows simple and efficient serotyping of pneumococci and may be applicable to latex agglutination reagents for typing or identification of other microorganisms. We recommend diluting antisera or removing centrifugation and wash steps for any latex reagents that fail QC. Our latex reagents are cost-effective, technically undemanding to prepare and remain stable for long periods of time, making them ideal for use in low-income countries. PMID:23379961

  18. Marla Rules

    ERIC Educational Resources Information Center

    Hassenpflug, Ann

    2006-01-01

    Assistant high school principal Elise Abbott is disturbed by the autocratic decision-making of the interim principal Marla Richardson. She meets with Marla to discuss Marla's approval of the English department chair's removal of master teacher Alice Tremont from gifted/talented courses. The chair reassigned the courses to herself. Although the…

  19. PALATAL DYSMORPHOGENESIS: QUANTITATIVE RT-PCR

    EPA Science Inventory

    ABSTRACT

    Palatal Dysmorphogenesis : Quantitative RT-PCR

    Gary A. Held and Barbara D. Abbott

    Reverse transcription PCR (RT-PCR) is a very sensitive method for detecting mRNA in tissue samples. However, as it is usually performed it is does not yield quantitativ...

  20. 78 FR 19533 - Investigations Regarding Eligibility To Apply for Worker Adjustment Assistance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-01

    .../One- Overland Park, KS...... 03/14/13 03/12/13 Stop). 82558 Abbott Diabetes Care Langhorne, PA 03/14..., OK 03/13/13 03/13/13 (Workers). 82555 Agfa Health Care (Company).. Carlstadt, NJ 03/13/13 03/12/13...

  1. Parent Empowerment and Teacher Professionalism: Teachers' Perspective

    ERIC Educational Resources Information Center

    Addi-Raccah, Audrey; Arviv-Elyashiv, Rinate

    2008-01-01

    School decentralization, which has reshaped power relations in the educational system, has empowered teachers and parents. Taking Abbott's approach to professions, the authors examine teachers' perceptions of the implications of parents' empowerment for teacher--parent relations. In-depth interviews with homeroom teachers in affluent urban…

  2. Comparison of Abbott Architect®, Siemens Immulite®, and Diasorin Liaison® for determination of Epstein-Barr virus serological diagnosis.

    PubMed

    François, Catherine; Segard, Christine; Bouvier, Maryline; Stefanski, Martine; Pannier, Christine; Zawadzki, Patricia; Roussel, Catherine; Hecquet, Denise; Duverlie, Gilles; Brochot, Etienne; Castelain, Sandrine

    2018-02-01

    This study compared the performance of 3 automated immunoassays, Architect ® (Abbott), Immulite ® (Siemens) and Liaison ® (Diasorin), for Epstein-Barr virus (EBV) serology. Ninety-one serum samples collected in Amiens University Hospital were analyzed for the presence of Viral Capsid Antigen (VCA) IgG and IgM and Epstein-Barr Nuclear Antigen (EBNA) IgG. The agreement between the 3 assays was calculated for each marker individually and for determination of the EBV profile, based on interpretation of the combination of these 3 EBV markers. Although similar results were obtained with Architect ® and Liaison ® , several discordant results were observed with Immulite ® , particularly for EBNA IgG. A large number of EBNA IgG-positive results were observed, which interfered with interpretation of the EBV profile. In contrast, Immulite ® performed similarly to the 2 other assays for detection of VCA IgM. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    PubMed

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.

  4. Analysis of an Attenuator Artifact in an Experimental Attack by Gunn-Allison-Abbott Against the Kirchhoff-Law-Johnson-Noise (KLJN) Secure Key Exchange System

    NASA Astrophysics Data System (ADS)

    Kish, Laszlo B.; Gingl, Zoltan; Mingesz, Robert; Vadai, Gergely; Smulko, Janusz; Granqvist, Claes-Göran

    2015-12-01

    A recent paper by Gunn-Allison-Abbott (GAA) [L. J. Gunn et al., Scientific Reports 4 (2014) 6461] argued that the Kirchhoff-law-Johnson-noise (KLJN) secure key exchange system could experience a severe information leak. Here we refute their results and demonstrate that GAA's arguments ensue from a serious design flaw in their system. Specifically, an attenuator broke the single Kirchhoff-loop into two coupled loops, which is an incorrect operation since the single loop is essential for the security in the KLJN system, and hence GAA's asserted information leak is trivial. Another consequence is that a fully defended KLJN system would not be able to function due to its built-in current-comparison defense against active (invasive) attacks. In this paper we crack GAA's scheme via an elementary current-comparison attack which yields negligible error probability for Eve even without averaging over the correlation time of the noise.

  5. Demise of Polymerase Chain Reaction/Electrospray Ionization-Mass Spectrometry as an Infectious Diseases Diagnostic Tool.

    PubMed

    Özenci, Volkan; Patel, Robin; Ullberg, Måns; Strålin, Kristoffer

    2018-01-18

    Although there are several US Food and Drug Administration (FDA)-approved/cleared molecular microbiology diagnostics for direct analysis of patient samples, all are single target or panel-based tests. There is no FDA-approved/cleared diagnostic for broad microbial detection. Polymerase chain reaction (PCR)/electrospray ionization-mass spectrometry (PCR/ESI-MS), commercialized as the IRIDICA system (Abbott) and formerly PLEX-ID, had been under development for over a decade and had become CE-marked and commercially available in Europe in 2014. Capable of detecting a large number of microorganisms, it was under review at the FDA when, in April 2017, Abbott discontinued it. This turn of events represents not only the loss of a potential diagnostic tool for infectious diseases but may be a harbinger of similar situations with other emerging and expensive microbial diagnostics, especially genomic tests. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  6. Germline mutations of KIT in gastrointestinal stromal tumor (GIST) and mastocytosis.

    PubMed

    Ke, Hengning; Kazi, Julhash U; Zhao, Hui; Sun, Jianmin

    2016-01-01

    Somatic mutations of KIT are frequently found in mastocytosis and gastrointestinal stromal tumor (GIST), while germline mutations of KIT are rare, and only found in few cases of familial GIST and mastocytosis. Although ligand-independent activation is the common feature of KIT mutations, the phenotypes mediated by various germline KIT mutations are different. Germline KIT mutations affect different tissues such as interstitial cells of Cajal (ICC), mast cells or melanocytes, and thereby lead to GIST, mastocytosis, or abnormal pigmentation. In this review, we summarize germline KIT mutations in familial mastocytosis and GIST and discuss the possible cellular context dependent transforming activity of KIT mutations.

  7. The challenges of lean manufacturing implementation in kitting assembly

    NASA Astrophysics Data System (ADS)

    Fansuri, A. F. H.; Rose, A. N. M.; Nik Mohamed, N. M. Z.; Ahmad, H.

    2017-10-01

    Literature studies shows that lean manufacturing goes way back with the original founder Eli Whitney in year 1799. The main purpose of lean manufacturing is to identify and eliminate waste in production. The application of lean manufacturing can be carried out in any industrial processes with regards to the understanding of lean principles, theories and practices. Kitting is one of the important aspects in a successful production. The continuous supply of materials from store to production has to be systematic and able to achieve lean standard for it to be successful. The objective of this paper is to review the implementation of lean manufacturing in kitting assembly. Previous papers show that, the implementation of lean manufacturing in kitting assembly may be beneficial to the organization such as reduce in space occupancy, part shortages, lead time and manpower. Based on previous research, some industries may tend to change between kitting and line stocking which are due to lack of understanding when implementing kitting and causes longer lead time and materials overflow in store. With a proper understanding on what to kit, where to kit, how to kit, why to kit and who kits the material with a standardised process flow may ensure the success of kitting.

  8. No GIST-type c-kit gain of function mutations in neuroblastic tumours

    PubMed Central

    Korja, M; Finne, J; Salmi, T T; Haapasalo, H; Tanner, M; Isola, J

    2005-01-01

    Aims: Neuroblastic tumours (NTs) have been shown to respond to imatinib treatment in vivo and in vitro, possibly via inactivating the c-kit receptor. The purpose of this study was to identify gastrointestinal stromal tumour (GIST)-type c-kit gene associated mutations in exons 9, 11, 13, and 17 in NTs to recognise a subset of tumours that would probably respond to imatinib treatment. Methods: Expression of the c-kit protein was detected immunohistochemically in a total of 37 archival paraffin wax embedded NTs using polyclonal rabbit antihuman c-kit antibody. After immunohistochemistry, c-kit gene associated chromosomal mutations in all cases of NT were detected with denaturing high performance liquid chromatography (HPLC). Results: Denaturing HLPC analysis did not reveal GIST-type mutations in four immunohistochemically detected c-kit positive or in 33 c-kit negative NTs. Conclusions: c-kit receptor expression and GIST-type c-kit gene mutations are rare events in NTs. Oncogenic activation of c-kit in NTs presumably differs from that of GISTs, which may influence their responsiveness to imatinib treatment. Whether c-kit has an essential role in the pathogenesis of NTs remains to be investigated. PMID:15976348

  9. Pim1 kinase regulates c-Kit gene translation.

    PubMed

    An, Ningfei; Cen, Bo; Cai, Houjian; Song, Jin H; Kraft, Andrew; Kang, Yubin

    2016-01-01

    Receptor tyrosine kinase, c-Kit (CD117) plays a pivotal role in the maintenance and expansion of hematopoietic stem/progenitor cells (HSPCs). Additionally, over-expression and/or mutational activation of c-Kit have been implicated in numerous malignant diseases including acute myeloid leukemia. However, the translational regulation of c-Kit expression remains largely unknown. We demonstrated that loss of Pim1 led to specific down-regulation of c-Kit expression in HSPCs of Pim1 -/- mice and Pim1 -/- 2 -/- 3 -/- triple knockout (TKO) mice, and resulted in attenuated ERK and STAT3 signaling in response to stimulation with stem cell factor. Transduction of c-Kit restored the defects in colony forming capacity seen in HSPCs from Pim1 -/- and TKO mice. Pharmacologic inhibition and genetic modification studies using human megakaryoblastic leukemia cells confirmed the regulation of c-Kit expression by Pim1 kinase: i.e., Pim1-specific shRNA knockdown down-regulated the expression of c-Kit whereas overexpression of Pim1 up-regulated the expression of c-Kit. Mechanistically, inhibition or knockout of Pim1 kinase did not affect the transcription of c-Kit gene. Pim1 kinase enhanced c-Kit 35 S methionine labeling and increased the incorporation of c-Kit mRNAs into the polysomes and monosomes, demonstrating that Pim1 kinase regulates c-Kit expression at the translational level. Our study provides the first evidence that Pim1 regulates c-Kit gene translation and has important implications in hematopoietic stem cell transplantation and cancer treatment.

  10. Early kit mortality and growth in farmed mink are affected by litter size rather than nest climate.

    PubMed

    Schou, T M; Malmkvist, J

    2017-09-01

    We investigated the effects of nest box climate on early mink kit mortality and growth. We hypothesised that litters in warm nest boxes experience less hypothermia-induced mortality and higher growth rates during the 1st week of life. This study included data from 749, 1-year-old breeding dams with access to nesting materials. Kits were weighed on days 1 and 7, dead kits were collected daily from birth until day 7 after birth, and nest climate was measured continuously from days 1 to 6. We tested the influences of the following daily temperature (T) and humidity (H) parameters on the number of live-born kit deaths and kit growth: T mean, T min, T max, T var (fluctuation) and H mean. The nest microclimate experienced by the kits was buffered against the ambient climate, with higher temperatures and reduced climate fluctuation. Most (77.0%) live-born kit deaths in the 1st week occurred on days 0 and 1. Seven of 15 climate parameters on days 1 to 3 had significant effects on live-born kit mortality. However, conflicting effects among days, marginal effects and late effects indicated that climate was not the primary cause of kit mortality. Five of 30 climate parameters had significant effects on kit growth. Few and conflicting effects indicated that the climate effect on growth was negligible. One exception was that large nest temperature fluctuations on day 1 were associated with reduced deaths of live-born kit (P<0.001) and increased kit growth (P=0.003). Litter size affected kit vitality; larger total litter size at birth was associated with greater risks of kit death (P<0.001) and reduced growth (P<0.001). The number of living kits in litters had the opposite effect, as kits in large liveborn litters had a reduced risk of death (P<0.001) and those with large mean litter size on days 1 to 7 had increased growth (P=0.026). Nest box temperature had little effect on early kit survival and growth, which could be due to dams' additional maternal behaviour. Therefore, we cannot confirm that temperature is the primary reason for kit mortality, under the conditions of plenty straw access for maternal nest building. Instead, prenatal and/or parturient litter size is the primary factor influencing early kit vitality. The results indicate that the focus should be on litter size and dam welfare around the times of gestation and birth to increase early kit survival in farmed mink.

  11. The clinical significance of c-Kit mutations in metastatic oral mucosal melanoma in China.

    PubMed

    Ma, Xuhui; Wu, Yunteng; Zhang, Tian; Song, Hao; Jv, Houyu; Guo, Wei; Ren, Guoxin

    2017-10-10

    c-Kit mutations are frequently detected in mucosal melanomas, but their clinical significance in metastatic oral mucosal melanomas (OMM) remains unclear. The main purpose of this study was to investigate the clinical and pathological features of metastatic OMMs with c-Kit mutations and the efficiency of the tyrosine kinase inhibitor imatinib in treating metastatic OMMs. We found thatresidual primary lesion and neck lymph nodes could act as independent prognostic factors in metastatic OMM patients. c-Kit mutations were detected in 22 out of 139 (15.8%) metastatic OMM patients. Under chemotherapy, the overall survival (OS) of c-Kit mutant patients was significantly shorter than that of wild-type patients. The Ki67 expression was significantly higher in c-Kit mutant patients than in wild-type patients. In distant metastatic OMM patients with c-Kit mutations, the treatment with c-Kit inhibitor resulted in a better OS. In conclusion, residual primary lesion, cervical lymph nodes and c-Kit mutations act as adverse prognostic factors of metastatic OMMs. The Kit inhibitor imatinib could benefit metastatic OMM patients with c-Kit mutations.

  12. Risk-based Strategy to Determine Testing Requirement for the Removal of Residual Process Reagents as Process-related Impurities in Bioprocesses.

    PubMed

    Qiu, Jinshu; Li, Kim; Miller, Karen; Raghani, Anil

    2015-01-01

    The purpose of this article is to recommend a risk-based strategy for determining clearance testing requirements of the process reagents used in manufacturing biopharmaceutical products. The strategy takes account of four risk factors. Firstly, the process reagents are classified into two categories according to their safety profile and history of use: generally recognized as safe (GRAS) and potential safety concern (PSC) reagents. The clearance testing of GRAS reagents can be eliminated because of their safe use historically and process capability to remove these reagents. An estimated safety margin (Se) value, a ratio of the exposure limit to the estimated maximum reagent amount, is then used to evaluate the necessity for testing the PSC reagents at an early development stage. The Se value is calculated from two risk factors, the starting PSC reagent amount per maximum product dose (Me), and the exposure limit (Le). A worst-case scenario is assumed to estimate the Me value, that is common. The PSC reagent of interest is co-purified with the product and no clearance occurs throughout the entire purification process. No clearance testing is required for this PSC reagent if its Se value is ≥1; otherwise clearance testing is needed. Finally, the point of the process reagent introduction to the process is also considered in determining the necessity of the clearance testing for process reagents. How to use the measured safety margin as a criterion for determining PSC reagent testing at process characterization, process validation, and commercial production stages are also described. A large number of process reagents are used in the biopharmaceutical manufacturing to control the process performance. Clearance testing for all of the process reagents will be an enormous analytical task. In this article, a risk-based strategy is described to eliminate unnecessary clearance testing for majority of the process reagents using four risk factors. The risk factors included in the strategy are (i) safety profile of the reagents, (ii) the starting amount of the process reagents used in the manufacturing process, (iii) the maximum dose of the product, and (iv) the point of introduction of the process reagents in the process. The implementation of the risk-based strategy can eliminate clearance testing for approximately 90% of the process reagents used in the manufacturing processes. This science-based strategy allows us to ensure patient safety and meet regulatory agency expectations throughout the product development life cycle. © PDA, Inc. 2015.

  13. Intratumoral CD3+ T-Lymphocytes Immunoexpression and Its Association with c-Kit, Angiogenesis, and Overall Survival in Malignant Canine Mammary Tumors

    PubMed Central

    Carvalho, Maria Isabel; Pires, Isabel; Dias, Marlene; Prada, Justina; Gregório, Hugo; Lobo, Luis; Queiroga, Felisbina

    2015-01-01

    In this study 80 malignant CMT were submitted to immunohistochemical detection of CD3, c-kit, VEGF, and CD31, together with clinicopathological parameters of tumor aggressiveness. CD3+ T-cells and c-kit overexpression revealed a positive correlation with VEGF (r = 0.503, P < 0.0001; r = 0.284, P = 0.023 for CD3 and c-kit, resp.) and CD31 (r = 0.654, P < 0.0001; r = 0.365, P = 0.003 for CD3 and c-kit, resp.). A significant association (P = 0.039) and a positive correlation (r = 0.263, P = 0.039) between CD3 and c-kit were also observed. High CD3/VEGF, c-kit/VEGF, and CD3/c-kit tumors were associated with elevated grade of malignancy (P < 0.0001 for all groups), presence of intravascular emboli (P < 0.0001 for CD3/VEGF and CD3/c-kit; P = 0.002 for c-kit/VEGF), and presence of lymph node metastasis (P < 0.0001 for all groups). Tumors with high CD3/VEGF (P = 0.006), c-kit/VEGF (P < 0.0001), and CD3/c-kit (P = 0.002) were associated with poor prognosis. Interestingly high c-kit/VEGF tumors retained their significance by multivariate analysis arising as independent prognostic factor. PMID:26346272

  14. Correction

    NASA Astrophysics Data System (ADS)

    2014-09-01

    An error was made in the spelling of the name of Mark Abbott, who was quoted in the news article "Earth observation plan looks toward balancing U.S. federal priorities," published in the 19 August 2014 issue of Eos (95(33), 295-296, doi:10.1002/2014EO330003). Eos regrets the error.

  15. Investigating the Abstractness of Children's Early Knowledge of Argument Structure

    ERIC Educational Resources Information Center

    McClure, Kathleen; Pine, Julian M.; Lieven, Elena V. M.

    2006-01-01

    In the current debate about the abstractness of children's early grammatical knowledge, Tomasello & Abbott-Smith (2002) have suggested that children might first develop "weak" or "partial" representations of abstract syntactic structures. This paper attempts to characterize these structures by comparing the development of constructions around…

  16. The Prevention Researcher, 1999.

    ERIC Educational Resources Information Center

    Ungerleider, Steven, Ed.

    1999-01-01

    Volume 6 of" The Prevention Researcher" contains three 12-page issues and one supplement. Issue Number 1 focuses on gambling, and contains the following articles: (1) "Gambling in the Family: The Hidden Addiction" (D. A. Abbott); (2) "Adolescent Gambling and Substance Use: The View from Texas" (L. Wallisch); (3)…

  17. THE NATIONAL CHILDREN'S STUDY: PROGRESS DEVELOPING METHODS APPROPRIATE FOR ASSESSING CHILDREN'S EXPOSURE, BIOMARKERS AND GENETIC SUSCEPTIBILITY

    EPA Science Inventory

    Invited presentation: no abstract submission fee required
    Introduction abstract for Workshop.

    CONTROL ID: 56947
    CONTACT (NAME ONLY): Barbara Abbott
    Abstract Details
    PRESENTATION TYPE: Invited Presentation : Workshop
    KEYWORDS: National Childrens Study, Ri...

  18. 31. Detail of Southeast Light lens and roof structure of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. Detail of Southeast Light lens and roof structure of light gallery, 1985. Taken day after Hurricane Gloria, courtesy of Gerald F. Abbott and Block Island Historical Society. - Block Island Southeast Light, Spring Street & Mohegan Trail at Mohegan Bluffs, New Shoreham, Washington County, RI

  19. The value of molecular expression of KIT and KIT ligand analysed using real-time polymerase chain reaction and immunohistochemistry as a prognostic indicator for canine cutaneous mast cell tumours.

    PubMed

    Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M

    2015-03-01

    This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.

  20. A meta-analysis of prognostic value of KIT mutation status in gastrointestinal stromal tumors

    PubMed Central

    Jiang, Zhiqiang; Zhang, Jian; Li, Zhi; Liu, Yingjun; Wang, Daohai; Han, Guangsen

    2016-01-01

    Numerous types of KIT mutations have been reported in gastrointestinal stromal tumors (GISTs); however, controversy still exists regarding their clinicopathological significance. In this study, we reviewed the publicly available literature to assess the data by a meta-analysis to characterize KIT mutations and different types of KIT mutations in prognostic prediction in patients with GISTs. Twenty-eight studies that included 4,449 patients were identified and analyzed. We found that KIT mutation status was closely correlated with size of tumors and different mitosis indexes, but not with tumor location. KIT mutation was also observed to be significantly correlated with tumor recurrence, metastasis, as well as the overall survival of patients. Interestingly, there was higher risk of progression in KIT exon 9-mutated patients than in exon 11-mutated patients. Five-year relapse-free survival (RFS) rate was significantly higher in KIT exon 11-deleted patients than in those with other types of KIT exon 11 mutations. In addition, RFS for 5 years was significantly worse in patients bearing KIT codon 557–558 deletions than in those bearing other KIT exon 11 deletions. Our results strongly support the hypothesis that KIT mutation status is another evaluable factor for prognosis prediction in GISTs. PMID:27350754

  1. Targeting c-KIT (CD117) by dasatinib and radotinib promotes acute myeloid leukemia cell death.

    PubMed

    Heo, Sook-Kyoung; Noh, Eui-Kyu; Kim, Jeong Yi; Jeong, Yoo Kyung; Jo, Jae-Cheol; Choi, Yunsuk; Koh, SuJin; Baek, Jin Ho; Min, Young Joo; Kim, Hawk

    2017-11-10

    Dasatinib and radotinib are oral BCR-ABL tyrosine kinase inhibitors that were developed as drugs for the treatment of chronic myeloid leukemia. We report here that the c-KIT (CD117) targeting with dasatinib and radotinib promotes acute myeloid leukemia (AML) cell death, and c-KIT endocytosis is essential for triggering c-KIT-positive AML cell death by dasatinib and radotinib during the early stages. In addition, dasatinib and radotinib reduce heat shock protein 90β (HSP90β) expression and release Apaf-1 in c-KIT-positive AML cells. Finally, this activates a caspase-dependent apoptotic pathway in c-KIT-positive AML cells. Moreover, the inhibition of c-KIT endocytosis by dynamin inhibitor (DY) reversed cell viability and c-KIT expression by dasatinib and radotinib. HSP90β expression was recovered by DY in c-KIT-positive AML cells as well. Furthermore, the effect of radotinib on c-KIT and HSP90β showed the same pattern in a xenograft animal model using HEL92.1.7 cells. Therefore, dasatinib and radotinib promote AML cell death by targeting c-KIT. Taken together, these results indicate that dasatinib and radotinib treatment have a potential role in anti-leukemic therapy on c-KIT-positive AML cells.

  2. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells

    PubMed Central

    Singh, Satyendra; Klarmann, Kimberly D.; Coppola, Vincenzo; Keller, Jonathan R.; Tessarollo, Lino

    2016-01-01

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies. PMID:27835883

  3. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells.

    PubMed

    Puverel, Sandrine; Kiris, Erkan; Singh, Satyendra; Klarmann, Kimberly D; Coppola, Vincenzo; Keller, Jonathan R; Tessarollo, Lino

    2016-12-20

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies.

  4. Changes in c-Kit expression levels during the course of radiation therapy for nasopharyngeal carcinoma.

    PubMed

    Jiang, Feng; Hu, Wei; Zhang, Bicheng; Xu, Jing; Shui, Yongjie; Zhou, Xiaofeng; Ren, Xiaoqiu; Chen, Xiaozhong; Shen, Li; Wei, Qichun

    2016-10-01

    In the era of intensity-modulated radiotherapy, distant metastasis is currently the main cause of treatment failure for nasopharyngeal carcinoma (NPC). Additional therapeutic strategies are required to control the metastasis and improve survival. One strategy is targeted therapy, for example against c-Kit. In the current study, the frequency of c-Kit expression was determined immunohistochemically in 106 NPC patients. c-Kit expression changes during the course of radiation therapy were detected in 41 cases via weekly biopsy. Twelve cases (11.3%) had c-Kit expression scores of 3 + and 16 (15.1%) had scores of 2 + . Thus, c-Kit overexpression (2 + or 3 + ) was observed in 28 (26.4%) patients. There were 35 (33.0%) and 43 (40.6%) patients with c-Kit expression scores of 1 + and 0, respectively. Furthermore, a trend of decreased c-Kit expression was observed after commencing radiotherapy according to the 41 NPC patients who were biopsied weekly. Therefore, c-Kit overexpression was identified to be common in NPC, and evaluating c-Kit as a therapeutic target for metastatic NPC via c-Kit overexpression subsequent to first line treatment may be of interest. To the best of our knowledge, the present study is the first to demonstrate a trend of decreased c-Kit expression during the course of radiotherapy.

  5. Developing Save Your Food Kit (Sayofu Kit) to Support Inquiry, Improve Student Learning Outcomes at SMP Plus Hidayatul Mubtadiin and Public Awareness on Food Additives

    NASA Astrophysics Data System (ADS)

    Astutik, J.

    2017-02-01

    Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of food additives.

  6. [Development of surgical antibioprophylaxis kits: evaluation of the impact on prescribing habits].

    PubMed

    Aouizerate, P; Guizard, M

    2002-01-01

    In our hospital, surgical antibioprophylaxis (ATBP) was too often administered too late, thus raising the infectious risk. Antibiotic stocks of the anaesthesia department were also systematically used, instead of nominal prescriptions of these drugs. The pharmacy could neither charge antibiotics to each surgical department nor quantify and differentiate ATBP from curative antibiotic therapy. The pharmacy and anaesthesia departments therefore set out to standardize surgical ATBP, in order to adapt this treatment to each surgical indication, and particularly in the case of allergy to beta-lactamase antibiotics (second line treatment kits). Consequently, prescription forms were developed and supplied to each surgery department, as well as ATBP kits. The kits were prepared and distributed by the pharmacy, and comprised boxes containing antibiotics in sufficient quantities to respect the protocols approved by the French Society of Anaesthesia and Resuscitation (SFAR). A protocol describing prescriptions, dispensation and administration has been presented to physicians and nurses. Fifteen surgical departments were included in our study and 30 different kits were prepared. From 1998 to 2001, 5586 surgical operations required administration of a kit (second line treatment kits in 5% of cases): 1848 (33%) in visceral surgery; 764 (13.8%) in urology; 802 (14%) in orthopaedics; 13 (0.2%) in vascular and thoracic surgery; 1236 (22%) in ear-nose-throat (ENT), periodontics and ophtalmology, and 923 (17%) in gynaecology and obstetrics. 93% of filled prescriptions forms were spontaneously returned to the pharmacy, the others were obtained during the renewal of kit stocks. The cost (over 4 years) of ATBP was quantified: 157,871 F for the 15 departments included, 26,123 F in visceral surgery, 13,520 F in urology, 73,741 F in orthopaedics, 569 F in vascular surgery, 39,720 F in ENT/ophthalmology/periodontics and 4,198 F in gynaecology and obstetrics. According to the Altemeier classification, 2226 class I, 3151 class II, and 209 class III surgical operations were performed. Since the kits have been brought into use, the committee for the protection against nosocomial infections (CLIN) has observed a reduction in the incidence of post-operative infections, according to the Altemeier classification: from 1.6% to 0.5% in class I, from 6.5% to 4.3% in class II, and from 11% to 8.5% in class III. The difference was statistically significant only for classes I (p < 0.01) and II (p < 0.001), and unchanged for class III (p = 0.3). No analysis was carried out for class IV (curative treatments). Both nurses and physicians have greatly appreciated the implementation of this organization. The advantage in terms of post-operative infections, administration exhaustiveness and stock management is obvious. The prescribed kits were systematically appropriate for the surgical interventions. In orthopaedics, cefamandole was used over 24 h (188 kits) in ligament plasty and osteotomy, or for 48 h (499 kits) in prosthetic surgery; 24 amoxicillin/clavulanic acid (first line) and 9 clindamycin/gentamicin (second line) single dose kits have been prescribed in traumatic indications. In ophthalmology, kits were only prescribed in endophtalmitis (24 ofloxacin/fosfomycin single amount kits), implant replacement or cornea graft (1076 ofloxacin 24 h kits) and cataract surgery in diabetic patients (12 ofloxacin single amount kits). In ENT and periodontics, 124 surgical operations required cefazolin single dose kits. In vascular surgery, 5 pefloxacin/gentamicin 48 h kits and 1 amoxicillin/clavulanic acid 48 h kit were used in contaminated limb amputation, 1 cefamandole 48 h kit in class I surgery and 1 vancomycin 24 h kit (betalactamase antibiotic allergy); in thoracic surgery, 1 cefamandole 24 h kit was used for a thoracic wound. In visceral surgery, 9 different kits have been used, depending on the opening (class II) or not (class I) of the digestive tract. 797 cefazolin (first line) and 68 clindamycin/gentamicin (second line) single dose kits were used in class I surgery, and 689 amoxicillin/clavulanic acid single dose (SD) kits in class II surgery. Specific protocols consisted of 18 ceftriaxone/metronidazole and 48 metronidazole/gentamicin SD kits in oesophagus surgery, 11 ceftriaxone and 17 gentamicin SD kits in biliary endoscopy, 137 metronidazole SD kits in proctology and 34 amoxicillin/gentamicin 6 h kits for prevention of endocarditis. In urology, 133 cefotaxime and 20 pefloxacin/gentamicin SD kits were precribed in renal lithiasis, 102 amoxicillin/clavulanic acid SD kits in cystectomy, 27 amoxicillin/gentamicin 6 h kits in endocarditis prevention and 58 cefamandole SD kits in all other indications. In gynaecology and obstetrics, 534 cefazoline and 19 clindamycin/gentamicin (second line) SD kits were used, and 370 doxycyclin SD kits were prescribed in pregnancy termination. Some departments (orthopaedics and visceral surgery) adapted the protocols to their needs, specifically with regard to treatment duration. However, these situations were quickly corrected. A constant follow-up and update of this system, associated with routine audits, should allow the maintenance and possibly the improvement of these results, hence shortening treatment duration.

  7. 49 CFR 173.165 - Polyester resin kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... resin kits consisting of a base material component (Class 3, Packing Group II or III) and an activator...

  8. Adaptation of commercial biomarker kits and proposal for 'drug development kits' to support bioanalysis: call for action.

    PubMed

    Islam, Rafiqul; Kar, Sumit; Islam, Clarinda; Farmen, Raymond

    2018-06-01

    There has been an increased use of commercial kits for biomarker measurement, commensurate with the increased demand for biomarkers in drug development. However, in most cases these kits do not meet the quality attributes for use in regulated environment. The process for adaptation of these kits can be frustrating, time consuming and resource intensive. In addition, a lack of harmonized guidance for the validation of biomarker poses a significant challenge in the adaptation of kits in a regulated environment. The purpose of this perspective is to propose a tiered approach to commercial drug development kits with clearly defined quality attributes and to demonstrate how these kits can be adapted to perform analytical validation in a regulated environment.

  9. The Use of Kits in the Analysis of Tissue Lipids Requires Validation.

    PubMed

    Rider, T; LeBoeuf, R C; Tso, Patrick; Jandacek, R J

    2016-04-01

    The ready availability and ease of use of kits for the measurement of serum lipids has greatly facilitated these measurements. In many cases it would be convenient to use these kits in the determination of lipid concentrations in tissues. The successful application of serum kits in tissue analysis requires that two important issues be considered. First, the solvent system for the extraction of the lipids and the solvent used for analysis by the kit must be compatible with the reactions in the kit. Second, the concentration range in the analyzed solution must be within the range for which the kit is used. We report here that lipids in liver and adipose tissues may be significantly underestimated by the use of some kits. We recommend that the use of kits for tissue analysis of lipids be validated for the specific analysis.

  10. Oncogenic activation of v-kit involves deletion of a putative tyrosine-substrate interaction site.

    PubMed

    Herbst, R; Munemitsu, S; Ullrich, A

    1995-01-19

    The transforming gene of the Hardy-Zuckerman-4 strain of feline sarcoma virus, v-kit, arose by transduction of the cellular c-kit gene, which encodes the receptor tyrosine kinase (RTK) p145c-kit. To gain insight into the molecular basis of the v-kit transforming potential, we characterized the feline c-kit by cDNA cloning. Comparison of the feline v-kit and c-kit sequences revealed, in addition to deletions of the extracellular and transmembrane domains, three additional mutations in the v-kit oncogene product: deletion of tyrosine-569 and valine-570, the exchange of aspartate at position 761 to glycine, and replacement of the C-terminal 50 amino acids by five unrelated residues. Examinations of individual v-kit mutations in the context of chimeric receptors yielded inhibitory effects for some mutants on both autophosphorylation and substrate phosphorylation functions. In contrast, deletion of tyrosine-569 and valine-570 significantly enhanced transforming and mitogenic activities of p145c-kit, while the other mutations had no significant effects. Conservation in subclass III RTKs and the identification of the corresponding residue in beta PDGF-R, Y579, as a binding site for src family tyrosine kinases suggests an important role for Y568 in kit signal regulation and the definition of its oncogenic potential. Repositioning of Y571 by an inframe two codon deletion may be the crucial alteration resulting in enhancement of v-kit oncogenic activity.

  11. M-COPA suppresses endolysosomal Kit-Akt oncogenic signalling through inhibiting the secretory pathway in neoplastic mast cells.

    PubMed

    Hara, Yasushi; Obata, Yuuki; Horikawa, Keita; Tasaki, Yasutaka; Suzuki, Kyohei; Murata, Takatsugu; Shiina, Isamu; Abe, Ryo

    2017-01-01

    Gain-of-function mutations in Kit receptor tyrosine kinase result in the development of a variety of cancers, such as mast cell tumours, gastrointestinal stromal tumours (GISTs), acute myeloid leukemia, and melanomas. The drug imatinib, a selective inhibitor of Kit, is used for treatment of mutant Kit-positive cancers. However, mutations in the Kit kinase domain, which are frequently found in neoplastic mast cells, confer an imatinib resistance, and cancers expressing the mutants can proliferate in the presence of imatinib. Recently, we showed that in neoplastic mast cells that endogenously express an imatinib-resistant Kit mutant, Kit causes oncogenic activation of the phosphatidylinositol 3-kinase-Akt (PI3K-Akt) pathway and the signal transducer and activator of transcription 5 (STAT5) but only on endolysosomes and on the endoplasmic reticulum (ER), respectively. Here, we show a strategy for inhibition of the Kit-PI3K-Akt pathway in neoplastic mast cells by M-COPA (2-methylcoprophilinamide), an inhibitor of this secretory pathway. In M-COPA-treated cells, Kit localization in the ER is significantly increased, whereas endolysosomal Kit disappears, indicating that M-COPA blocks the biosynthetic transport of Kit from the ER. The drug greatly inhibits oncogenic Akt activation without affecting the association of Kit with PI3K, indicating that ER-localized Kit-PI3K complex is unable to activate Akt. Importantly, M-COPA but not imatinib suppresses neoplastic mast cell proliferation through inhibiting anti-apoptotic Akt activation. Results of our M-COPA treatment assay show that Kit can activate Erk not only on the ER but also on other compartments. Furthermore, Tyr568/570, Tyr703, Tyr721, and Tyr936 in Kit are phosphorylated on the ER, indicating that these five tyrosine residues are all phosphorylated before mutant Kit reaches the plasma membrane (PM). Our study provides evidence that Kit is tyrosine-phosphorylated soon after synthesis on the ER but is unable to activate Akt and also demonstrates that M-COPA is efficacious for growth suppression of neoplastic mast cells.

  12. M-COPA suppresses endolysosomal Kit-Akt oncogenic signalling through inhibiting the secretory pathway in neoplastic mast cells

    PubMed Central

    Hara, Yasushi; Obata, Yuuki; Horikawa, Keita; Tasaki, Yasutaka; Suzuki, Kyohei; Murata, Takatsugu; Shiina, Isamu; Abe, Ryo

    2017-01-01

    Gain-of-function mutations in Kit receptor tyrosine kinase result in the development of a variety of cancers, such as mast cell tumours, gastrointestinal stromal tumours (GISTs), acute myeloid leukemia, and melanomas. The drug imatinib, a selective inhibitor of Kit, is used for treatment of mutant Kit-positive cancers. However, mutations in the Kit kinase domain, which are frequently found in neoplastic mast cells, confer an imatinib resistance, and cancers expressing the mutants can proliferate in the presence of imatinib. Recently, we showed that in neoplastic mast cells that endogenously express an imatinib-resistant Kit mutant, Kit causes oncogenic activation of the phosphatidylinositol 3-kinase-Akt (PI3K-Akt) pathway and the signal transducer and activator of transcription 5 (STAT5) but only on endolysosomes and on the endoplasmic reticulum (ER), respectively. Here, we show a strategy for inhibition of the Kit-PI3K-Akt pathway in neoplastic mast cells by M-COPA (2-methylcoprophilinamide), an inhibitor of this secretory pathway. In M-COPA-treated cells, Kit localization in the ER is significantly increased, whereas endolysosomal Kit disappears, indicating that M-COPA blocks the biosynthetic transport of Kit from the ER. The drug greatly inhibits oncogenic Akt activation without affecting the association of Kit with PI3K, indicating that ER-localized Kit-PI3K complex is unable to activate Akt. Importantly, M-COPA but not imatinib suppresses neoplastic mast cell proliferation through inhibiting anti-apoptotic Akt activation. Results of our M-COPA treatment assay show that Kit can activate Erk not only on the ER but also on other compartments. Furthermore, Tyr568/570, Tyr703, Tyr721, and Tyr936 in Kit are phosphorylated on the ER, indicating that these five tyrosine residues are all phosphorylated before mutant Kit reaches the plasma membrane (PM). Our study provides evidence that Kit is tyrosine-phosphorylated soon after synthesis on the ER but is unable to activate Akt and also demonstrates that M-COPA is efficacious for growth suppression of neoplastic mast cells. PMID:28403213

  13. U. S. Veterinary Immune Reagents Network: Progress with poultry immune reagents development

    USDA-ARS?s Scientific Manuscript database

    A major obstacle to advances in veterinary immunology and disease research is the lack of sufficient immunological reagents specific for veterinary animal species. In 2006, U. S. Veterinary Immune Reagent Network (VIRN) Consortium (www.vetimm.org) was developed to develop immune reagents against ma...

  14. Sequential addition reactions of two molecules of Grignard reagents to thioformamides.

    PubMed

    Murai, Toshiaki; Ui, Kazuki; Narengerile

    2009-08-07

    Sequential addition reactions of two molecules of Grignard reagents to thioformamides were found to yield tertiary amines in an efficient manner. The addition of two different Grignard reagents can be accomplished by using one equivalent of arylmagnesium reagent in the first step. In the second step, a variety of reagents such as alkyl, alkenyl, aryl, and alkynyl reagents were used to afford the corresponding amines in good to high yields.

  15. A national survey of home-based care kits for palliative HIV/AIDS care in South Africa.

    PubMed

    Mabude, Z A; Beksinska, M E; Ramkissoon, A; Wood, S; Folsom, M

    2008-09-01

    The objective of this study was to assess home-based care (HBC) kits and programs in South Africa to evaluate the feasibility of scaling up kit production and distribution. South African HBC organizations received structured questionnaires; key informant interviews and a literature review were completed to assess systems for production, distribution and supply of HBC kits. Meetings with stakeholders were held in two Provinces to share and analyze the study findings. The study team distributed questionnaires to 466 organizations and conducted interviews with representatives from 45 organizations, the Provincial Department of Health (DoH) and manufacturers of kits. All identifiable HBC organizations in South Africa were included in the survey. As a result 215 HBC organizations returned questionnaires; including non-governmental organizations (56%), community-based organizations (32%) and organizations affiliated with government health departments. Two types of kits were available: a home kit and a professional kit. The demand for HBC kits exceeded availability, kit contents and availability varied considerably and the supply chain was irregular. Kit production and distribution systems were fragmented. Replenishment of kit items was problematic. End-users are mostly caregivers who have not received adequate training on their use. The study shows that substantial work has been done by HBC organizations in South Africa to respond to the need for palliative care supplies within resource constraints. The growing demand for kits exceeds the supply. There is a need to improve the supply chain management of HBC kits, strengthen referral systems and links between community-based organizations and government departments, expand training opportunities for care givers, and develop monitoring and evaluation systems.

  16. Single-cell analysis of the fate of c-kit-positive bone marrow cells

    NASA Astrophysics Data System (ADS)

    Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D.; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa

    2017-10-01

    The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.

  17. Single-cell analysis of the fate of c-kit-positive bone marrow cells.

    PubMed

    Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa

    2017-01-01

    The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.

  18. In-frame Val216-Ser217 deletion of KIT in mild piebaldism causes aberrant secretion and SCF response.

    PubMed

    Hattori, Mai; Ishikawa, Osamu; Oikawa, Daisuke; Amano, Hiroo; Yasuda, Masahito; Kaira, Kyoichi; Ishida-Yamamoto, Akemi; Nakano, Hajime; Sawamura, Daisuke; Terawaki, Shin-Ichi; Wakamatsu, Kaori; Tokunaga, Fuminori; Shimizu, Akira

    2018-03-21

    Piebaldism is a pigmentary disorder characterized by a white forelock and depigmented patches. Although the loss-of-function mutations in the KIT gene underlie the disease, the intracellular dynamics of the mutant KIT are largely unknown. We herein report a Japanese family with piebaldism in which the affected members showed a mild phenotype. The objective of this study is to investigate the functions and intracellular dynamics of the mutant KIT protein. We performed genetic analyses of the KIT gene using peripheral blood cells. We analyzed the intracellular localization of the mutant KIT protein in HEK293T cells transfected with wild-type (Wt) and/or mutant KIT genes. Immunoprecipitation analyses, immunoblotting and immunofluorescence studies were performed using antibodies against KIT and downstream signaling proteins. Glycosidase digestion analysis was performed to clarify the intracellular localization of KIT protein. A genetic analysis revealed a novel heterozygous mutation c.645_650delTGTGTC which results in the in-frame deletion of Val 216 and Ser 217 in the extracellular domain of KIT. Immunoprecipitation analyses confirmed that the wild and mutant KIT formed a heterodimer after treatment with stem cell factor (SCF); however, the phosphorylation of the downstream signaling factors was decreased. In an immunofluorescence study, the mutant KIT accumulated predominantly in the endoplasmic reticulum (ER) and was sparsely expressed on the cell surface. A glycosidase digestion study revealed that the mutant KIT is predominantly localized in the ER. These data reveal an aberrant function and intracellular localization of mutant KIT protein in piebaldism. Copyright © 2018 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  19. Loss of c-Kit function impairs arteriogenesis in a mouse model of hindlimb ischemia.

    PubMed

    Hernandez, Diana R; Artiles, Adriana; Duque, Juan C; Martinez, Laisel; Pinto, Mariana T; Webster, Keith A; Velazquez, Omaida C; Vazquez-Padron, Roberto I; Lassance-Soares, Roberta M

    2018-04-01

    Arteriogenesis is a process whereby collateral vessels remodel usually in response to increased blood flow and/or wall stress. Remodeling of collaterals can function as a natural bypass to alleviate ischemia during arterial occlusion. Here we used a genetic approach to investigate possible roles of tyrosine receptor c-Kit in arteriogenesis. Mutant mice with loss of c-Kit function (Kit W/W-v ), and controls were subjected to hindlimb ischemia. Blood flow recovery was evaluated pre-, post-, and weekly after ischemia. Foot ischemic damage and function were assessed between days 1 to 14 post-ischemia while collaterals remodeling were measured 28 days post-ischemia. Both groups of mice also were subjected to wild type bone marrow cells transplantation 3 weeks before hindlimb ischemia to evaluate possible contributions of defective bone marrow c-Kit expression on vascular recovery. Kit W/W-v mice displayed impaired blood flow recovery, greater ischemic damage and foot dysfunction after ischemia compared to controls. Kit W/W-v mice also demonstrated impaired collateral remodeling consistent with flow recovery findings. Because arteriogenesis is a biological process that involves bone marrow-derived cells, we investigated which source of c-Kit signaling (bone marrow or vascular) plays a major role in arteriogenesis. Kit W/W-v mice transplanted with bone marrow wild type cells exhibited similar phenotype of impaired blood flow recovery, greater tissue ischemic damage and foot dysfunction as nontransplanted Kit W/W-v mice. This study provides evidence that c-Kit signaling is required during arteriogenesis. Also, it strongly suggests a vascular role for c-Kit signaling because rescue of systemic c-Kit activity by bone marrow transplantation did not augment the functional recovery of Kit W/W-v mouse hindlimbs. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. GLUCOCORTICOID RECEPTOR REGULATION IN THE RAT EMBRYO: A POTENTIAL SITE FOR DEVELOPMENTAL TOXICITY?

    EPA Science Inventory

    Glucocorticoid receptor regulation in the rat embryo: a potential site for developmental toxicity?

    Ghosh B, Wood CR, Held GA, Abbott BD, Lau C.

    National Research Council, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711, USA.

Top